RS-04-104, Second Interval Inservice Inspection Program Relief Request I2R-46
| ML042050325 | |
| Person / Time | |
|---|---|
| Site: | Byron |
| Issue date: | 07/22/2004 |
| From: | Ainger K Exelon Generation Co, Exelon Nuclear |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| RS-04-104 | |
| Download: ML042050325 (17) | |
Text
Exelon Generation www.exeloncorp.com 4300 Winfield Road Warrenville, I L 60555 RS-04-104 July 22, 2004 U.S. Nuclear Regulatory Commission ATTN : Document Control Desk Washington, DC 20555-0001 Subject : Second Interval Inservice Inspection Program Relief Request 12R-46 In accordance with 10 CFR 50.55a, "Codes and standards," paragraph (a)(3)(i), Exelon Generation Company, LLC (EGC), is requesting relief from the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components," on the basis that the proposed alternative provides an acceptable level of quality and safety.
Specifically, this proposed alternative would allow Byron Station to use ASME Code Case N-652, "Alternative Requirements to Categories B-G-1, B-G-2, and C-D Bolting Examination Methods and Selection Criteria," in lieu of the ASME Code,Section XI, 1989 Edition requirements for class 1 and 2 bolting examination methods. The details of the request for relief are enclosed.
EGC requests approval of this request by February 2005 in order to support the Byron Station, Unit 1 refueling outage scheduled to start March 1, 2005. Should you have any questions concerning this letter, please contact David J. Chrzanowski at (630) 657-2816.
Respectfully, Byron Station, Units 1 and 2 Facility Operating License Nos. NPF-37 and NPF-66 NRC Docket Nos. STN 50-454 and 50-455 Kenneth A. Ainger Manager, Licensing Attachment : 10 CFR 50.55a Relief Request 12R-46 10 CFR 50.55a
BYRON STATION UNITS 1 and 2 Request for Relief for Alternative Requirements to the ASME Code Section X1 Class I and 2 Bolting Examination Methods and Selection Criteria In Accordance with 10 CFR 50.55a(a)(3)(i)
Use of ASME Code Case N-652 1. ASME CODE COMPONENT(S) AFFECTED Drawing Numbers :
10 CFR 50.55a RELIEF REQUEST 12R-46 Revision 0 (Page 1 of 16)
Code Classes :
1 and 2
Reference:
Table IWB-2500-1 and Table IWC-2500-1 Examination Categories: B-G-1, B-G-2, and C-D Item Numbers:
Component Numbers:
- 2. APPLICABLE CODE EDITION AND ADDENDA
- 4. REASON FOR THE REQUEST SECOND INTERVAL ISI PROGRAM PLAN All item numbers applicable to these examination categories All Unit 1 and Unit 2 components applicable to these categories (See Table 2 for Complete Listing)
All Unit 1 and Unit 2 drawings with components applicable to these categories (See Table 2 for Complete Listing)
The current inservice inspection program is based on the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code,Section XI, 1989 Edition with no Addenda.
3. APPLICABLE CODE REQUIREMENTS Table IWB-2500-1, Examination Categories B-G-1 "Pressure Retaining Bolting, Greater Than 2 Inches in Diameter," and B-G-2, "Pressure Retaining Bolting, 2 Inches and Less in Diameter," and Table IWC-2500-1 Examination Category C-D, "Pressure Retaining Bolting, Greater Than 2 Inches in Diameter," contain requirements for the selection, scheduling, and examination of component bolting. Specific requirements are identified for each item number within these categories.
As an alternative to the ASME Code, 1989 Edition,Section XI requirements, EGC requests NRC approval to use ASME Code Case N-652, "Alternative Requirements to Categories B-G-1, B-G-2, and C-D Bolting Examination Methods and Selection Criteria." Use of Code Case N-652 will supplement the 1989 Edition,Section XI requirements in the areas of examination methods, selection criteria, and scheduling of examinations.
The 1989 Edition is not specific in the subject of selection and scheduling requirements for all of the components in these categories. Use of the code case will clarify these requirements.
Use of Code Case 1`0652 will reduce the radiological dose during an outage by :
- a.
limiting examinations to a single component in a group that are similar in design, type, and function ;
BYRON STATION UNITS I and 2 SECOND INTERVAL ISI PROGRAM PLAN 10 CFR 50.55a RELIEF REQUEST 12R-46 Revision 0 (Page 2 of 16)
- b.
eliminating highly restrictive examinations on in-place components (the bolting components may be examined after removal) ; and
- c.
eliminating redundant examinations of components that are repeatedly disassembled during the interval (this would include flange surfaces).
Use of Code Case N-652 will reduce the time and examination costs during an outage by:
- a. eliminating multiple examinations on Class 1 closure head studs and
- b. allowing the use of surface methods on bolting that have complex shapes which are not readily examined using field volumetric methods.
In addition, portions of the ASME Code, 1989 Edition, requirements for examination of Class 1 bolting are duplicated by examinations performed for other programs such as the examination of the bolted connection of components containing borated fluids and the pressure test programs.
The highlighted items in Table 2 of this request identify fifty-nine component numbers at Byron Station that would benefit from the alternative examination rules of ASME Code Case N-652.
Given that these component numbers are typically composed of multiple examination points (for example, the reactor vessel close stud component number consists of 58 studs that each require examination), the radiation dose savings during an outage can be significant. However, quantification of the radiation dose savings is difficult since the components cover a variety of plant locations all subject to varying radiation dose fields. The radiation dose impact also depends on the degree of required examination support (e.g., scaffolding, insulation removal) and the duration of the examination (i.e., volumetric, surface, or visual).
- 5. PROPOSED ALTERNATIVE AND BASIS FOR USE In accordance with to 10 CFR 50.55a(a)(3)(i), relief is requested on the basis that the proposed alternative will provide an acceptable level of quality and safety. Examinations of Class 1 and 2 bolting will substitute the requirements of the current 1989 Section XI programs with the alternatives presented in ASME Code Case N-652. The changes using this code case are divided into three areas as follows.
A.
Examination Methods of Components in Examination Categories B-G-1 and C-D Use of visual methods of closure head nuts :
The ASME Code, 1989 Edition, of Section XI Table IWB-2500-1 does not list the examination requirements/figure numbers or the acceptance standards for Item B6.10. Itstates ina footnote that these requirements are "in course of preparation." Code Case N-627 was published by the ASME allowing the substitution of surface examination methods with visual methods. This code case was approved for use by the NRC in Regulatory Guide 1.147, Revision 13. However, Code Case N-627 does not specify the examination areas or acceptance standards. This missing information regarding the examination areas and acceptance standards for the closure head nuts is supplied in (lode Case N-652.
Elimination of the distinction of in-place and removed closure head studs:
Closure head studs require a volumetric examination whether the studs are removed or remain in-place. Item Numbers B6.20 (in-place) and B6.30 (removed) were combined into a
BYRON STATION UNITS 1 and 2 SECOND INTERVAL ISI PROGRAM PLAN 10 CFR 50.55a RELIEF REQUEST 12R-46 Revision 0 (Page 3 of 16) single item 86.20 in Code Case N-652 and the additional surface examination is optional for removed studs. The surface method may replace the volumetric method for removed studs per Note (2). The option of surface or volumetric examinations for closure head studs is incorporated in later editions of the ASME Code and these later editions have been endorsed in 10 CFR 50.55a.
Use of surface methods as an alternative to volumetric examinations :
For bolting of components other than reactor vessels, (136.60, 86.90, B6.120, 86.150, 86.180, 86.210, and all of Class 2 Category C-D) a surface examination may also be substituted for the volumetric method per B-G-1 Note (2) and C-D Note (2). This change makes the examination requirements consistent for all bolting components greater than 2 inches in diameter. The option to use surface methods in lieu of volumetric methods also facilitates examination of studs and bolts with complex shapes that are not easily examined using field volumetric techniques.
B. Selection Criteria for Various Components Heat exchangers, pumps, and valves :
Code Case N-652, Category B-G-1 Notes (4 and 5) and Category B-G-2 Note (2) clarify the selection requirements for these components to reflect the selection requirements of the associated vessels (B-B), pumps (B-L-2), and valves (B-M-2). This modifies the criteria specified in the 1989 Edition of the ASIVIE Code, Category B-G-1, Note (3) that stated the examinations are limited to those components selected under the other categories. These other categories divided the components into groups based on size, design, and function.
Code Case N-652 now includes the corresponding conditions in the selection of the bolting for these components. This criterion is unchanged in Category C-D.
Piping flange components :
Code Case N-652, Category B-G-1 Note (6) and Category B-G-2 Note (3) added the selection requirements that these components may be divided into groups based on size, design, and function and that the examination may be limited to one component within the group. This establishes a grouping criteria similar to the one used for heat exchangers, pumps, and valves. In addition, the 1989 Edition of the ASIVIE Code required that the examinations are limited to those components selected for examination under the piping Category B-J for Class 1 and Category C-F for Class 2. The 1989 Edition of the ASME Code definition of component as it applies to Categories B-J and C-F is unclear. Byron Station has conservatively applied this condition to select all piping flanges within the Class 1 piping boundary. Byron Station has also adopted risk-informed inservice inspection using Code Case N-578-1. Use of Code Case N-578-1 eliminates examination categories B-J and C-F. Code Case N-652 establishes a selection criterion without using these category references.
C. Scheduling Changes with N-652 Deferral of examination for B-G-1 Components :
The 1989 Edition of the ASME Code has Note (5) allowing deferral to the end of the interval if no leakage of borated water is detected. This note applied to all items in the category. Code Case N-652 replaced this note by allowing a deferral for all components. Subsequently, the
BYRON STATION UNITS 1 and 2 SECOND INTERVAL ISI PROGRAM PLAN 10 CFR 50.55a RELIEF REQUEST 12R-46 Revision 0 (Page 4 of 16) allowance of this deferral results in a conclusion that examination of B-G-1 components need only be performed once in the inspection interval.
B-G-1 Visual Examinations of Heat Exchanger, Pumps, and Valves :
Code Case N-652 clarifies that for components that are disassembled the examination need only be performed once in the interval. Some components such as steam generator manway bolting may be disassembled more than once in an inspection interval and the clarification by Code Case N-652 will eliminate redundant examinations of these components.
In-place examinations of B-G-2 components :
Code Case N-652 eliminates visual examinations of in-place, under tension, bolting components. These examinations are highly limited in access to all of the required surfaces for the visual examination. These assembled components are also VT-2 examined once per outage for the insulated borated bolted connections where applicable per IWA-5242(a) and all are examined for the VT-2 examination performed at nominal pressure and temperature. If leakage occurs at a bolted connection, the bolting shall be removed for visual examination under both category B-G-2 and IWA-5250(a)(2).
Code Case N-652 does not specify use of specific ASME Code editions or addenda. Code Case N-652 is applicable for the 1977 Edition of the ASME Code through the 1998 Edition with the 2000 Addenda. The ASME Code,Section XI is endorsed through the 2000 Addenda as documented in 10 CFR 50.55a(b)(2). With respects to personnel and equipment certifications, details of examination techniques, and applicable examination figures and acceptance standards, EGC will use the applicable portions of the 1989 Edition of the ASME Code.
The proposed alternative will provide an acceptable level of quality and safety given that :
A. The alternative approach was produced within the ASME organization.
B. Alternative examination methods are as capable of detecting service-induced flaws as the original methods.
C. Alternative selection and scheduling criteria clarify the original examination categories and are supplemented by additional activities from other portions of Section XI.
EGC proposes to substitute the requirements of the ASME Code, 1989 Edition, of Section X1 for examination categories B-G-1, B-G-2, and C-D with the alternative requirements presented in ASME Code Case N-652.
- 6. DURATION OF PROPOSED ALTERNATIVE This relief request will be implemented during the remainder of Byron Station, Units 1 and 2 second ten-year inservice inspection interval or until the NRC approves Code Case N-652 in a future revision of the applicable Regulatory Guide during the current inspection interval.
- 7. PRECEDENTS There are no precedents in the form of relief requests, however, as highlighted in Table 1 of this request, several aspects of Code Case N-652 have been incorporated into those ASME Code Section XI editions already approved by the N RC in 10 CFR 50.55a{b}(2).
BYRON STATION UNITS 1 and 2 SECOND INTERVAL ISI PROGRAM PLAN
- 8. ATTACHMENTS 10 CFR 50.55a RELIEF REQUEST 12R-46 Revision 0 (Page 5 of 16)
Table 1 : Comparison of the ASME Code Section XI, 1989 Edition, Tables IWB/C-2500-1 to ASME Code Case N-652 Tables 1, 2, and 3 This table lists the changes to the subject examination categories by using the code case. The table also highlights those portions of Code Case N-652 that have been incorporated into the ASME Code, 1998 Edition through the 2000 Addenda. The ASME Code, 1998 Edition through the 2000 Addenda, has been endorsed in Paragraph (b)(2) of 10 CFR 50.55a. For additional information, aspects of Code Case N-652 that have been incorporated into the ASME Code, 2001 Edition through the 2003 Addenda, are shown. Currently, this code edition and addenda have not been endorsed in 10 CFR 50.55a. Category C-D is not applicable to Byron Station at this time.
No Class 2 bolting at Byron Station is over 2 inches in diameter.
Table 2 : Byron Station B-G-1 and B-G-2 Components Only item numbers applicable to each Byron Station unit are identified in the table. For pumps and valves, the groupings shown are established by the associated Category B-L-2 or B-M-2 groupings. For piping flanges, the groupings are based on design, size, function, and service as specified in ASME Code Case N-652. Selections of valves disassembled during the current interval are shown.
Items, which provide a specific benefit for Byron Station with the approval of ASME Code Case N-652, are highlighted in Table 2.
BYRON STATION UNITS 1 and 2 RELIEF REQUEST 12R-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 6 of 16)
Table 1 : Comparison of ASME Code Section XI, 1989 Edition, Tables IWBIC-2500-1 to ASME Code Case N-652 tables 1, 2 and 3 EXAMINATION CATEGORY B-G-1, ALTERNATE RULES FOR PRESSURE RETAINING BOLTING, GREATER THAN 2 in. IN DIAMETER CATEGORY ISSUE COMMENTS Deferral of Examination to End of Interval.
All items numbers are allowed to be deferred until the end of the interval with Code Case N-652. The ASME Code, 1989 Edition, would allow this deferral under the condition that no boron leakage is detected per Note (5). This change was also incorporated into later 10 CFR 50.55a endorsed editions and addenda.
Examination Requirements and Figure Exam requirements now identified in Code Case N-652. Requirements listed as "In course of preparation" in Numbers for Item 86.10 (Closure Head Nuts).
the ASME Code, 1989 Edition
. This change was also incorporated into the ASME Code, 1998 Edition through the 2000 Addenda.
Examination Method for Item 86.10 (Closure The examination method was changed to visual method. This change was also incorporated into the ASME Head Nuts).
Code, 1998 Edition through the 2000 Addenda.
Acceptance Standard for Item 136.10 (Closure Acceptance standard added, previously listed as "In course of preparation" in the ASME Code, 1989 Edition.
Head Nuts).
This change was also incorporated into the ASME Code, 1998 Edition through the 2000 Addenda Item Numbers 136.20 (Closure Studs, in place)
Separate items merged into single item 136.20 in Code Case N-652. This change was incorporated into the and 136.30 (Closure Studs, when removed).
ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
Closure Studs Examination Requirements Examination method changes from surface and volumetric to volumetric only. This change was also incorporated into the ASME Code, 1998 Edition through the 2000 Addenda, but the examination requirements are shown as surface or volumetric.
Code Case N-652 Note (2).
This note allows the substitution of the volumetric examination methods with a surface method
. This note is also incorporated into the ASME Code, 1998 Edition through the 2000 Addenda Code Case N-652 Note (4 ).
This note modifies requirements stated in the ASME Code, 1989 Edition, Note (3). N-652 note allows grouping of components similar to types that are similar in design, type, and function. The ASME Code, 1989 Edition, only limits the selection by related examination category. This change was incorporated into the 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
Code Case N-652 Note (5).
Code Case N-652 Note (5) modifies requirements stated in the ASME Code, 1989 Edition, Note (3) that limited examination to those components selected under other examination categories. Code Case N-652 Note (5) removed reference to piping components, which were moved into a separate note (see below). Code Case N-652 Note (5) also clarifies requirement that examination is needed only once for components repeatedly disassembled during the interval. These changes were incorporated into the ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
Code Case N-652 Note (6).
Code Case N-652 Note (6) modifies requirements stated in the ASME Code, 1989 Edition, Note (3). Code Case N-652 Note (6) allows grouping of piping flanges similar to Code Case Note (5). This change was incorporated into the ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
BYRON STATION UNITS 1 and 2 RELIEF REQUEST 1211-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 7 of 16)
Table 1 : Comparison of the ASME Code Section XI, 1989 Edition, Tables IWB/C-2500-1 to N-652 tables 1, 2 and 3 (cont'd)
EXAMINATION CATEGORY B-G-1, ALTERNATE RULES FOR PRESSURE RETAINING BOLTING, GREATER THAN 2 in. IN DIAMETER (cont'd)
CATEGORY ISSUE COMMENTS ASME Code, 1989 Edition, Note (5).
This note is deleted in Code Case N-652. This note allowed deferral on the condition that no boric acid from the bolted connection is found during the interval. Deferral of all item numbers is allowed by Code Case N-652 without condition
. This change was also incorporated into the ASME Code, 1998 Edition through the 2000 Addenda, but the examination requirements are shown as surface or volumetric.
EXAMINATION CATEGORY B-G-2, ALTERNATE RULES FOR PRESSURE RETAINING BOLTING, 2 in. AND LESS IN DIAMETER CATEGORY ISSUE COMMENTS Item Number B7.80 (control rod drive housing Item deleted in the code case. This change was also incorporated into the ASME Code, 1998 Edition through Bolts, Studs, and Nuts) the 2000 Addenda. This note is not applicable to Byron Station. All B-G-2 reactor vessel bolting is classified as B7.10.
Code Case N-652 Note (1).
Code Case N-652 note eliminates in-place examinations. In-place examinations limited in access to subject surfaces by component configuration. This change was incorporated into the ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
Code Case N-652 Note (2).
Code Case N-652 Note (2) modifies requirements stated in ASME Code, 1989 Edition Note (2). Steam generators and heat exchangers are combined into single vessel reference. Code Case N-652 Note (2) removed reference to piping components, which were moved into a separate note (see below). Note also clarifies requirement that examination is needed only once for components repeatedly disassembled during the interval such as manways. These changes were incorporated into the ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
Code Case N-652 Note (3).
Code Case N-652 Note (3) modifies requirements stated in ASME Code, 1989 Edition Note (2). Code Case N-652 Note (3) allows grouping of piping flanges similar to Code Case N-652 Note (2). Code Case N-652 Note (3) also clarifies the requirement that examination is needed only once for components repeatedly disassembled during the interval. This change was incorporated into the ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
BYRON STATION UNITS I and 2 RELIEF REQUEST 1211-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 8 of 16)
Table 1 : Comparison of the ASIVIE Code Section XI, 1989 Edition, Tables IWB/C-2500-1 to N-652 tables 1, 2 and 3 (cont'd)
EXAMINATION CATEGORY C-D, ALTERNATE RULES FOR PRESSURE RETAINING BOLTING GREATER THAN 2 in. IN DIAMETER CATEGORY ISSUE COMMENTS Code Case N-652 Note (2).
Code Case N-652 Note (2) allows substitution of exam method to align with Class 1 requirement. This change was incorporated into the ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
Code Case N-652 Note (3).
Minor change to ASME Code, 1989 Edition, Note (2). Code Case 10652 note replaces "where the component" with "when the component." This charge was incorporated into the ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
Code Case N-652 Note (4).
Code Case N-652 Note (4) eliminates reference to piping category C-F. Code Case N-652 Note (4) also allows grouping of piping flanges into groupings similar to Class I piping flanges. This change was incorporated into the ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
Code Case N-652 Note (5).
Code Case N-652 Note (5) expands requirement for subsequent examinations in successive intervals to include the sequence of the future examinations. This change was incorporated into the ASME Code, 2001 Edition through 2003 Addenda (currently not endorsed by 10 CFR 50.55a).
BYRON STATION UNITS 1 and 2 RELIEF REQUEST 12R-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 9 of 16)
A: All components of item/group required. Ch Disassembled component required. G : Minimum of one of Table 2 : Byron B-G-1 and B-G-2 Components. group sampled. S : Surface exam. V : Volumetric exam. VT : Visual exam. X: Selected Item Isometric Component ISI Identifier Current Program With Code Case N-652 Category Drawing Number Description Type Exam Selected Type Exam Selected B-G-1 86.10 1 RPV-1 1 RC-01 -R N01-N54 Reactor Vessel Closure Head Nuts A
VT VT B-G-1 86.20 I RPV-1 1RC-01-R S01-S54 Reactor Vessel Closure Head Studs (in place)
A 11 V
401 86.30 1 RPV-1 1RC-01-R S01-S54 Reactor Vessel Closure Head Studs (removed)
A S and V B-G-1 86.40 1 RPV-1 IRC-01-R FLG THREADS 01-54 Reactor Vessel Threads-In-Flange A
B-G-1 86.50 1 RPV-1 IRC-01-R W01-W54 Reactor Vessel Closure Head Washers A
VT x
A VT VG-1 86.90 1SGT1 1RC010A STUDS-CL 0100 Steam Generator Manway Studs (Cold Leg)
X 13-G-1 86.90 1SG-01 1RC-01-BA STUDS-HL 01-20 Steam Generator Manway Studs (Hot Leg)
X TG-1 86.90 1SGT2 1RC&1Q8 ---- STUDS-CL 01-20 Steam Generator Mamay Studs (Cold Leg X
TG-1 86.90 1SGT2 1RCOUBB STUDS HL 01-20 Steam Generator Manway Studs (Hot Leg)
A V
X A
V (or S)
X B-G-1 86.90 1 SGT3 1RC010C STUDS-CL 0100 Steam Generator Manway Studs (Cold Leg)
X X
B-G-1 86.90 ISGW3 1RC0106 STUDS-Hl- 0100 Steam Generator Manway Studs (Hot Leg)
I
~........... -
X X
B-G-1 86.90 1 SG-04 1RC010D STUDS-CL 0100 Steam Generator Manway Studs (Cold Leg)
-X X
B-G-1 86.90 1 SG-04 1RC-01-BD STUDS-HL 01-20 Steam Generator Manway Studs (Hot Leg)
X X
NG-1 86.100 1 SG-01 1 RC-01-BA FLG SURF-CL Steam Generator ld Leg)
.............I......
Manway-Flange Surface,.(Cold x
x B-G-1 86.100 1SGT1 1RC-01-EA 10
.1 1-19 S.-F ML HL Steam Generator Manway Flange
... ~~qa~S 2!r
..l::eg..)..
B-G-1
......... I I
86.100
... I I.-I 1SG42
....1.....R
......Q01-EB
..0
....1....-..E
......B F
..L
..G
.........S
......U
..R
....F
. -CL Steam m G
.............e Generator Generator Generator M
......a
..m
.... a x
x B-G-1 86.100 I SG-02 1 RC-01-BB FLG SURF-HL Steam Generator Manway Flange Surface (Hot Leg)
A VT x
A VT 1
x
.... 1.1-11-I.-
B-G-1
......... I I
I 86.100 1111-1,11 1SGT3 1.1-1-.1 1RTOUBC FLG SURF-CL I"....
............... 11-11.1"..."
Swam Generator Mama x
B-G-1 86.100 1SG-03 1 RC-01-BC
. 11
- -l-FLG SURF-HL Steam Generator Manway Flange Surface (Hot Leg)
I
..... I........
x X
B-G-1 86.100 1-1.1--
1SGA4
............. I......
1RCT1aD FLG SURF-CL Steam Generator B-G-1 86.100 1 SG-04
... -.1-.....
IRC-01-BD
. -1.11,...................
FLG SURF-1 Steam Generator Manway Flange Surface (Hot Leg) x X
B-G-1 86.110 1 SG-01 I RC-01-BA NUTS-CL 01-20 Steam Generator Mama Nuts (Cold Lea) x x
B-G-1 86.110 1 SG-01
... I............
1 RC-01-BA NUTS-HL 01-20 Steam Generator Manway Nuts (Hot Leg)
....... I........
x B-G-1 86.110 1SGT2 1RC-0101121 NUTS-CL 0140 Steam Generator Mamay Nuts (Cold Leg)..........
X...
1.1-11" B-G-1
. 1.1.111.11.1.
86.110 ISG-02 1 RC-01-BB
.1---
I I................
NUTS-1 01-20 Steam Generator Mamay,Nuts Hot Leg) x A
VT B-G-1 B6.110 1SGT3
... I................
. 1-............. -.1" 1RQ01-EC NUTS-CL 0140
....... 111-1-1..........
Mamay.."s (old !~!q)
V I B-G-1 86.110 1SGT3 1R501-BC NUTS-HL 0140 Steam Generator Manway Nuts B-G-1 B6.110 I
1SGA4
.............. I 1=0141D I..
. I..................
NUTS-CL 0140
.11.1 1 -......
Steam Generator Mama y Nuts (Cold leg)
X.....
TG-86.110,
1SGW4 IRC010D 01-20
, NUTS-HL Swam Generator Manway Nuts Mot Leg) x
BYRON STATION UNITS 1 and 2 RELIEF REQUEST 12R-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 10 of 16)
Table 2 : Byron B-G-1 and B-G-2 Components. A: All components of item/group required. D: Disassembled component required. G : Minimum of one of (cont'd) group sampled. S: Surface exam. V: Volumetric exam. VT : Visual exam. X: Selected I
Isometric Component I
p I
Current Program With Code Case N-652 Category Item ISlldentifier Descri tion Drawing Number B-G-1 86.180 I 1RCP-1 1RC-01-PA LS01-S24 Reactor Coolant
. Pump
,Main
..,Flange.Studs....,....,.,.....,
.....-1-1 I.
Type Exam I Selected I Type Exam I Selected p G V
I
......J p, G B-G-1 B G
.1......
... 86.190 B6.19p 1 RCP-1 1-RCP-1 1 RC-01-PC 1RC-01-Pp H
FLG SURF FLG SURF
.... Reactor Coolant Pump Main Flange Surface Reactor Coolant Pump Main Flange
-ge Surface s, Bushings, and Washers s, Bushings, and Washers j
s, Bushings, and Washers
, Bushings, and Washers Valve Flange Surface D G D, G D, G V
D, D G D G VT D G D, G VT DG VorS DG VorS D G VT D, G VT B-G-11 B-G-1 l86.180 1
1 RCP-1 I 1 RC-01-PB 86.180 1RCP-1 1RC-01-PC 1S01-S24 1
S01-S24 Reactor Coolant Pump Main
. Flange.. Studs.,.,..
Reactor Coolant Pump
,. Main
... Flange., Studs...
B-G-1 86.180 I 1 RCP-1 11 RC-01-PD S01-S24 Reactor Coolant Pump Main Flange Studs B-G-1 86.190 1 RCP-1 I RC-01-PA FLG SURF Reactor Coolant Pump Main Flange Surface B-G-1 86.190 I RCP-1 1 RC-01-PB FLG SURF Reactor Coolant Pump Main Flange Surface B-G-11 B-G-1 B-G-1 B-G-1 B.-G.-.~..........
86.200 86.200
..86.200 86.200, 86.21, 0, 1 RCP-1 1 RCP-1 I..RCP-1 1 RCP-1 RC,-0 1 RC-01-PA 1 RC-01-PB 1..RC-01-PC 1 RC-01-PD 1 RC8001A.,.,.,,
NBW-01-24 NBW-01-24 NBW-01-24 NBW-01-24 Bolts 1-24 RCP Main Flange Nu RCP Main Flange Nu RCP Main Flange Nu RCP Main Flange Nut Valve Studs B-G-1 86.210 1 RC-02 1RC8001B Bolts 1-24 Valve Studs B-G-1 86.210 1 RC-03 1 RC8001 C Bolts 1-24 Valve Studs B -G-1 B6.210 1.RC 04 1RC8001 p
Bolts
.1-24' Valve Studs-B-G-1 B6.210 1 RC-01 1 RC8002A Bolts 1-24 Valve Studs B-G-1 86.210 1 RC-02 C8002B Bolts 1-24 Valve Studs B-G-1 86.210 1 RC-03 1 RC8002C Bolts 1-24 Valve Studs B-G-1 86.210 1.RC-04.......
1-RC8002p Bolts
..1-24.
valve Studs B-G-1 86.220 1 RC-01 1 RC8001 A FLG SURF Valve Flange Surface B-G-11 86.220 1 RC-02 1 RC8001 B FLG SURF Valve Flange Surface B-G-11 86.220 1 RC-03 1 RC8001 C FLG SURF Valve Flange Surface B-G-1 B6 22o...
1 RC-04 1-RC8001
....~.......
p FLG SURF v....
Valve Flange Surface B-G-11 86.220 1 RC-01 1 RC8002A FLG SURF Valve Flange Surface 86.220 1 RC-02 1 RC8002B FLG SURF Valve Flange Surface B-G-11 86.220 1 RC-03 1 RC8002C FLG SURF Valve Flange
.Surface,..
B-G-1 86.220 1 RC-04 1 RC8002D FLG SURF
BYRON STATION UNITS I and 2 RELIEF REQUEST 1211-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 11 of 16)
Table 2: Byron B-G-1 and B-G-2 Components. A: All components of item/group required. D: Disassembled component required. G: Minimum of one of (cont'd) group sampled. S: Surface exam. V: Volumetric exam. VT : Visual exam. X: Selected Isometric Component Current Program MY Code Case 14152 Category Item Drawing Number ISI Identifier Description Type Exam Selected Tye Exam Selected i B-G-1 136.230 1RC-01 1RC8001A NBW 1-24 Valve Nuts, Washers.
..Bushings,
...and
...... 11.1111111.111---
B-G-1 136.230 I
1 RC-02
. -.1.1 11 1
1 1 RC8001 B 111 NBW 1-24
............... Valve Nuts, Bushings, and Washers
-111111 1.1 i
D, G VT D, G 1
136 1 RC 03 I RC8001 C NBW 104 Valve Nuts, Bushin s, and Washers B-G-1 B6.2**30 Valve Nuts, 'B
-- us' hi*n'g"s
', a nd Wa Washers i
&G-1 136.230 1 RC-01 I RC8002A NBW 1-24 Valve Nuts, Bushings,
.-and Washers..........
x X
Bushings, and Washers 11 1.........
i D, G VT D, G 1
VT B-G-1 86.230 1RCT3 1RCW02C NB"W 104 Valve Nuts shin % and Washers
.I f
.....1
-11, B-G-1 136.230 1 RC-04 1 RC8002D NBW 1-24 Valve Nuts, Bushings, and Washers B-G-2 BT10 1 RPV-1 IRC-01-R CLAMPS-CETC Reactor Vessel NBW 1 -10 Articu-clamps (5 Sets)
A VT X
A VT B-G-2 BT10 1 RPV-1 1RC01A CLAMP&RVUS Reactor Vessel NBW 1-2 Articu-clamps (2 Sets)
A VT x
A B-G-2 137.20 1PZR-1 1RY-01-S BLT 106 Pressurizer Manway Bolts and Washers A
VT x
A VT B-G-2 B7.50 1 CV-06 1CV14GA-1.5 FLG 1-4 Piping Range Studs, Nuts, and Washers X
B-G-2 B7.50 1 CV-03 1CV14GB-1.5 FLG 1-4
............ Piping Flange Studs, Nuts, and Washers A
VT X
G VT B-G-2 B7.50 ICV-16 ICV14GC-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B-G-2 B7.50 1 CV-06 ICV14GD-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B-G-2 B7.50 1 RC-23 1RC22AA-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B-G-2 B7.50 1 RC-21 1RC22AB-1.5 FLG 1-4 Rping Flange Studs, Nuts, and Washers A
VT X
It G VT B-G-2 B7.50 I RC-27 IRC22AC-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B-G-2 B7.50 1 RC-20 1RC22AD-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
TG-2 B7.50 1 RC-32 1 RY031346 FLG 1d2 Piping FKnge Studs, NuW and VAKers X
x B-G-2 B7.50 I RC-32 1 RY03BB-6 FLG 1-12 Piping Flange Studs, Nuts, and Washers VT X
D, G VT B-G-2 B7.50 1 RC-32 1RY03BC-6 FLG 1-12 Rping Flange Studs, Nuts, and Washers X
B-G-2 B7.50 1SI-23 1 RU602 FLG 1-8 Piping Flange Studs, Nuts, and Washers A
VT X
D VT B-G-2 B7.50 ISI-19 1SI08HA-2 FLG 1-8 Piping Flange Studs, Nuts, and Washers X
B-G-2 B7.50 ISI-18 1SI08HB-2 FLG 1-8 Piping Flange Studs, Nuts, and Washers A
VI X
D
, G VT TGA BT50 1SI-20 ISMBH52 FTG 1-8 Piping Flange Studs, Nuts, and Washers
. I.................
X YGO B710 1SI-20 1SI08HD-2 FLG 1-8 Piping Flange Studs, Nuts, and Washers X
I I
BYRON STATION UNITS 1 and 2 RELIEF REQUEST 12R-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 12 of 16)
Table 2: Byron B-G-1 and B-G-2 Components. A: All components of item/group required. D : Disassembled component required. G: Minimum of one of
. VT : Visual exam. X: Selected B G-2 ]
B-G-2 87.70
.............1....
B-G-2 G-2-.
B7.70 B7.70 87.70 1 SI-10 1 SI-05 1 SI-09 1 SI-09 1 S18818C 1 SI8948B 1 SI8948C 1S18948p BLT.
...-18 BLT 1-18 B
LT
.1.-1
.8.....
Valve Bonnet Studs, Nuts, Bushings, and.Washers.,.,
Valve Bonnet Studs, Nuts, Bushings, and Washers Valve Bonnet Studs, Nuts, Bushings, and Washers
.
in
.and Washers -
Valve Bonnet Studs, Nuts, Bus
- Bushings, Current Program D G D, G D G VT D G D, G D G Selected D G With Code Case N-652 Type Exam D
D G VT D, G VT D G VT D G VT D, G VT D G VT D, S VT Selected X
D G (cont'd) group sampled. S : Surface exam. V: Volumetric exa Category Item Isometric Drawing Component Number ISI Identifier Description 6-G ?
B.Sn i SI-i CI 1&0)-'JA-l
.5 FLG 1 4 Flange Studs, Juts, and Washers B-G-2 B7.50 1SI-17 1 SIO8JB-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers B-G-2 87.50 1 SI-20 1 SI08JC-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers B-G-2 B7.50 1 SI-20 1 S108JD-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers B-G-2 B7.60 1 RCP-1 1 RC-01-PA BLT 1-36 RCP Shaft Seal Bolts, Washers, and Nuts B-G-2 B7.60 1 RCP-1 1 RC-01-PB BLT 1-36 RCP Shaft Seal Bolts, Washers, and Nuts B-G-2 B7.60 1 RCP-1 1 RC-01-PC BLT 1-36 RCP Shaft Seal Bolts, Washers, and Nuts B-G-2
-87
.60 1
.RCP...
.C-1R01-PD BLT 1-36 RCP. Shaft Seal Bolts, Washers, Nuts-.....
B-G-2 B7.70 1 RC-06 1 RC8003A BLT.,1-12.
Washers ValveBonnet, Studs,,., Nuts,.. Bushings,.
, and.,
B-G-2 67.70 1 RC-09..
1 RC8003B BLT
. -..-...2....
Valve Bonnet
- Nuts, and Washers
. Studs,.
Bushings,.
.........al B-G-2 87.70 1 RC-12 1 RC8003C BLT 1-12 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G 2
87.70 1
R C-15 1 RC8003D B
LT 1-12 Valve Bonnet Studs, Nuts, Bushings, and Washers g-G-2 B7.70 1 RH-02 1 RH8701 A BLT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers
.-G B-2 87.70 1 RH-02 1RH8701B..
BLT
..1
..1.8.....
Valve Bo nnet Studs Nuts gus.1in and Washers g-G-2 87.70 1 RH-01 1 RH8702A BLT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2....
8 7.70 1RC-1
.1.........
I RH8702B BLT
..1.-1.8.....
V a Ive Bon Bonnet Studs Nuts g.....
.Bushings, 9, nd Washers B.--G-.2.
B7 70 1 RC-32 1
,RY8010A, BLT 1.-8...
Valve
. Bonnet. Studs,,.. Nuts, Bushings,.. and Washers B-G-2 87.70 1 RC-32 1RY80108 BLT 1-8 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2
.......87
.70 1.RC-32.
1-RY801 OC BLT 1-$
Valve Bonnet Studs, Nuts, Bushings, 8........
.and Washers B-G-2 B7.70 1 SI-03 1SI8818A BLT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 B7.70 1S -06 1SI8818B BLT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers BLT 1-16 B-G-2 87.70 1 SI-14 1 SI8818D BLT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 B.G-2
........ 87.70 1 SI-02 1S18841A 87
. LT
.70 1 S1-11 1SI8841 g BLT
..11.--11.&6 Valve Bonnet Studs, Nuts, Bushings, and Washers Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 B7.70 1 SI-01 1 S18948A BLT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers
BYRON STATION UNITS 1 and 2 RELIEF REQUEST 12R-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 13 of 16)
Table 2: Byron B-G-1 and B-G-2 Components. A : All components of item/group required. D : Disassembled component required. G : Minimum of one of B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B
86.50 86.180 136.180 136.180 86.180 86..1.90, L._B6.,1.90 86.190 86.190 2RPV-3 2RCP-1 2RCP-1 2RCP-1 2RCP-1 2RCP-1......
2RCP-.1......
2RCP-1 2RCP-1 2RC-01-R 2RC-01-PA 2RC-01-PB 2RC-01-PC 2RC-01-PD 2RC-01-PA 2RC-0,1.-PB.....
2RC-01-PC 2RC-01-PD W01-W54 S01-S24 S01-S24 S01-S24 S01-S24 FLG SURF.....,..
FLG. SURF............
FLG SURF FLG SURF Reactor Vessel Closure Head Washers Reactor Coolant Pump Main Flange Studs Reactor Coolant Pump Main Flange Studs Reactor Coolant Pump Main Flange Studs.
Reactor Coolant Pump Main Flange Studs Reactor Coolant Pump Main Flange Surface Reactor Coolant Pump Main Flange Surface Reactor Coolant Pump Main Flange Surface
~.--..
.surface.
Reactor Coolant Pump a' Flang
.a D,
D, G D G VT D, G V
D, G I V (or S)
(
)
(cont'd) group sampled. S : Surface exam. V: Volumetric exam. VT : Visual exam. X : Selected Category Item Isometric Component ISI Identifier Description Current Program With Code Case N-652 Drawing Number Type Exam Selected Type Exam Selected B-G-2 87.70 1 SI-02 1SI8949A BLT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 87.70 1 RC-22 1 SI8949B BLT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers D G VT D G VT 87.70,..
ISI-11 1 S18949C.....
BLT 1-16, Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 87.70 1 RC-22 1S18949D BLT.1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 137.70 1 SI-01 1 S18956A BLT.. 1..-?..8 Valve Bonnet Studs, Nuts, Bushings, and Washers B.-G.-2....
87.70 1 SI-05 1S189568...........
... BLT....118 Valve Bonnet Studs Nuts Bushings, and Washers D, G D, G VT B-G-2 87.70 1 SI-09 1 SI8956C BLT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers B -G-2 87.70 -
1 SI-13
-1S18956p B LT 1-18 Valve Bonnet Studs Nuts Bushings and Washers B-G-1 86.10 2RPV-1 2RC-01-R N01-N54 Reactor Vessel Closure Head Nuts A
X A
VT X
B-G-1 86.30 2RPV-3 2RC-01-R S01-S54 Reactor Vessel Closure Head Studs (in place)
A V
X A
V X
B-G-1 86.30 2RPV-3 2RC-01-R S01-S54 Reactor Vessel Closure Head Studs (removed) nd V V (or S)
B-G-1 86.40 2RPV-1 2RC-01-R FLG THREADS 01-54 Reactor Vessel Threads-In-Flange A
V X
A V
X A
VT X
A VT X
B-G-1 B-G-1 B-G-1 B
.-G-1 86.200 2RCP-1,
. 2RC-01.,-PA, 86.200 2RCP-1 2RC-01-PB 86.200 2RCP-1 2RC-01-PC 86.200 2RCP-2RC-01-Pp NBW.1.-24 NBW 1-24 NBW 1-24 NBW
.1-24 RCP Main Flange Nuts,. Bushings,.
Washers
. and,.
RCP Main Flange Nuts, Bushings, and Washers RCP Main Flange Nuts, Bushings, and Washers RCP Main Flan 9e Nuts, Bushings, -and Washers B-G-1 86.210 2RC-01 2RC8001A S01-S24 Studs
- Bushings, B-G-1 86.210 2RC-02 2RC8001 B S01-S24 Valve Studs B-G-1 86.210 2RC-03 2RC8001 C S01-S24 Valve Studs BG1 86.210 2RC-04 2RC8001 D S01-S24 Valve Studs
BYRON STATION UNITS 1 and 2 RELIEF REQUEST 12R-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 14 of 16)
Table 2 : Byron B-G-1 and B-G-2 Components. A: All components of item/group required. D: Disassembled component required. G: Minimum of one of B-G-2 B-G-2 B-G-2 B G 87.30 87.30 87.30 67.30 2SG-01 2SG-03 2SG-02 2SG-04 2RC-01-BA 2RC-01-BB 2RC-01-BC 2RC-01-BD BLT 1-32 (2 sets)
BLT 1-32 (2 sets)
BLT 1-32 (2 sets)
BLT 1-32 (2 sets)
Steam Generator Manway Studs and Washers Steam Generator Manway Studs and Washers Steam Generator Manway Studs and Washers Steam Generator Manway Studs and Washers Pressurizer Manway Bolts and Washers (cont'd) group sampled. S : Surface exam. V: Volumetric exam. VT : Visual exam. X: Selected Item Category Isometric Component ISI Current Program With Code Case N-652 Drawing Number Identifier Description Type Exam Selected Type Exam Selected B-G,-1,.,........ 86.21.0 2RC-01
. 2RC8002A
'S01-S24
. Valve Studs B-G.-1
. 86.210 2RC-02 2RC8002B i S01-S24
. Valve Studs p G V
E.........
..j p, G V
B.-G-1 86.210 2RC-03 2RC8002C Valve Studs I
I SO
.S0
.....1-S24........
B -
G_1
.8 6.210
.2 RC-04 C
2 R
..80....2 0
D S
.....2 Valve Studs V_.
B-G-1 66.220 2RC-01 2RC8001A FLG SURF Valve Flange Surface B-G-1 I
a 86.220.....
2.RC-02
........ 2RC8001 B...
FLG SURF
................ Valve
. Flange
. Surface D, G D, G VT B-G-1 86.220 2RC-03 2RC8001 C FLG SURF Valve Flange Surface B-
....... -BS
.22o 2.RC-04.
2RC8001 p
FLG SURF Valve Flange
.-Surface-B-G-1 86.220 2RC-01
..... 2RC8002A FLGSURF Flange Surface Valve B-G-1 86.220 2RC-02 2RC8002B FLG SURF Valve Flange Surface D G VT D G VT B-G-1 86.220 2RC-03 2RC8002C FLG SURF Valve Flange Surface B-G-1 86.220 2
RC.......
2RC8002p FLG SURF a
Valve Flange g surface B-G-1 86.230 4
.... 2RC8001A,.
N..gW..
..1..-24...
Valve Nuts, Bushings, and Washers B-G-1 L
....... 86.230,.,.,
2RC--02..
.... 2RC8001.8
. N.gW...?.-24.....
Valve Nuts, Bushings, and Washers D, G VT D, G VT B-G-1 86.230 2RC-03 2RC8001C NBW 1-24 Valve Nuts, Bushings, and Washers
-86
.230 2RC-04 2RC8001 p
NBW 1
-24 Valve
..utts Nuts
.Bushings,
.and Washers B-G-1 86.230 2RC-01 2RC8002A NBW 1-24 Valve Nuts, Bushings, and Washers B-G-1 86.230 2RC-02 2RC8002B NBW 1-24 Valve Nuts, Bushings, and Washers D G VT D G VT B-G-1 86.230 2RC-03 2RC8002C NBW 1-24 Valve Nuts, Bushings, and Washers B-G-1 86.230 2RC-04
.. 2RC8002p
...................111.11.11.1 ---
Valve Nutsuts, Bushings, and Washers B-G-2 I
87.10 2RPV-1 j 2RC-01-R I CLAMPS-CETC Reactor Vessel NBW 1-10 Articu-clamps (5 Sets)
A VT X
I A
VT X
B-G-2 87.10 2RPV-1 2RC-01-R CLAMPS-RVLIS Reactor Vessel NBW 1-2 Articu-clamps (2 Sets)
A X
A X
B-G-2 87.20 2PZR-1 2RY-01-S MANWAY 01-16 A
X A
X
BYRON STATION UNITS 1 and 2 RELIEF REQUEST 1211-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 15 of 16)
Table 2: Byron B-G-1 and B-G-2 Components. A: All components of item/group required. D: Disassembled component required. G : Minimum of one of (cont'd) group sampled. S: Surface exam. V: Volumetric exam. VT : Visual exam. X: Selected Item Isometric Component ISI Identifier Current Program With Code Case N-652 Category Drawing Number Description Type Exam Selected Type Exam Selected 6-G-2 B7.50 2CV-06 2CV14GA-'1.5 FLG 1-4 Piping Flange Studs, Nuts, and V'Jashors X
B -G-2 B7.50 2CV 03 2CV14GB 1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
A VT D, G VT B-G-2 137.50 2CV-16 2CV14GC-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B G 2 137.50 2CV-06 2CV14GD 1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers B-G-2 137.50 2RC-23 2RC22AA-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B -G-2 B7.50 2RC-19 2RC22AB-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers A
VT D, G s,
VT B-G-2 137.50 2RC-27 2RC22AC-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B G 2 137.50 2RC-20 2RC22AD 1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B-G-2 137.50 2RC-32 2RY03BA-6 FLG 1-12 Piping Flange Studs, Nuts, and Washers X
B-G-2 137.50 2RC-32 2RY03BB-6 FLG 1-12 Piping Flange Studs, Nuts, and Washers A
VT X
D, G VT B-G-2 137.50 2RC-32 2RY03BC-6 FLG 1-12 Piping Flange Studs, Nuts, and Washers X
B-G-2 137.50 2S1-23 2RY76A-2 FLG 1-8 Piping Flange Studs, Nuts, and Washers A
VT X
C1 VT B-G-2 137.50 2SI-19 2SI08HA 2 FLG 1-8 Piping Flange Studs, Nuts, and Washers.,...
X..,.
B-G-2 137.50 2SI-18 2SI08HB-2 FLG 1-8 Piping Flange Studs, Nuts, and Washers A
VT X
D, G' VT B-G-2 137.50 2SI-20 2SI08HC-2 FLG 1-8 Piping Flange Studs, Nuts, and Washers X
B-G-2 137.50 2S1-20 2SI08HD-2 FLG 1-8 Piping Flange Studs, Nuts, and Washers B -G-2 17.50 2SI-19 2S108JA-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B-G-2 B7.50 2SI-18 2S108JB-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers...
A VT X
D, G YT B-G-2 137.50 2SI-20 2S108JC-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X
B-G-2 137.50 2SI-20 2S108JD-1.5 FLG 1-4 Piping Flange Studs, Nuts, and Washers X....
B-G-2 137.60 2RCP-1 2RC-01-PA BLT 1-36 RCP Shaft Seal Bolts, Washers, and Nuts B-G-2 137.60 2RCP-1 2RC-01-PB BLT 1-36 RCP Shaft Seal Bolts, Washers, and Nuts D, G VT D, G VT B-G-2 137.60 2RCP-1 2RC-01-PC BLT 1-36 RCP Shaft Seal Bolts, Washers, and Nuts B G 2 87.60 2RCP-1 RC 01 PD BLT 1-36 RCP Shaft Sea' Bolts iNashers
. and Nuts B-G-2 87.70 2RC-06 2RC8003A BLT 1-12 Valve Bonnet Studs, Nuts, Bushings,, and Washers B-G-2 87.70 2RC-09 2RC8003B BLT 1-12 Valve Bonnet Studs, Nuts, Bushings, and Washers D, G VT D, G VT B-G-2 137.70 2RC-12 2RC8003C BLT 1-12 Valve Bonnet Studs, Nuts, Bushings, and Washers B G 2 87.70 2RC-15 2RC8003D BLT 1-12 Valve Bonnet Studs, Nuts, Bushings, and
---/Dashers B-G-2 87.70 2RH-02 2RH8701A BLT 1-18 Valve Bonnet Studs, Nuts, Bushings, and. Was D, G VT D, G VT B-G-2 137.70 2RH-02 2RH8701B BLT 1-18 Valve Bonnet Studs, Nuts, Bushings, -'an-d-Washers
BYRON STATION UNITS 1 and 2 RELIEF REQUEST 12R-46, Revision 0 SECOND INTERVAL ISI PROGRAM PLAN (Page 16 of 16)
Table 2 : Byron B-G-1 and B-G-2 Components. A : All components of item/group required. D : Disassembled component required. G : Minimum of one of (cont'd) group sampled. S : Surface exam. V : Volumetric exam. VT : Visual exam. X : Selected Item Isometric Component Current Program With Code Case N-652 Category ISI Identifier Description Drawing Number Type Exam Selected Type Exam Selected B-G-2 B7.70 2RH-01 2RH8702A BILT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers BG2
-87
.70 2RC
.1.1....
2RH8702B BILT Vale Bonnet V.
Studs, utBushings, ushing5 and Washers D G VT D G VT B-G-2 87.70 2RC-32 2RY8010A BILT 1-8 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 67.70 2RC-32 2RY8010A gLT
..-8.................
Valve Bonnet Studs, Nuts, Bushings, and Washers 1
D, G D, G VT B-G-2 87.70 2RC-32 2RY8010A BILT 1-8 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 -- B7.70 2SI-03 2SI8818A BILT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 87.70.......
2SI-06 2SII88188
. BLT....
..6...........
Valve Bonnet Studs, Nuts, Bushings, and Washers D, G D, G B-G_2 11 B7.70 2SI-10...
..... 2SI8818C.,..,
BLT.,1-1,6.....
Valve Bonnet
. Studs,
,..Nuts,
.Bushings,.and,Washers Washers B-G-2 li 87.70 2SI-14 2SI8818D BILT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers
.ii B-G-2 87.70 2SI-02.
...... 2SI8841A.
BILT 1-16,...........
Valve Bonnet Studs, Nuts, Bushings, and Washers D, G VT D, G VT B-G_2 87.70 2SI-11 2SI8841 B BLT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 87.70 2SI-01 2SI8948A BILT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 87.70 2SI-05 2SI8948B BLT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers D G VT D G VT B-G-2 87.70 2SI-09 2SI8948C BLT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 87.70 2SI-13 2SI8948D BILT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 87.70 2SI-02 2SI8949A BILT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers B.-.G-.2 87.70 2RC-22,
..... 2SI8949B,..
BLT....1..-.1..6............
Valve Bonnet Studs, Nuts, Bushings, Washers...,
and..
D, G VT D, G VT B-G-2 87.70 2SI-11 2SI8949C BILT 1-16 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2_
8 7.70 2RC-22 2SI8949D BILT
.1.-1s..........
Valve Bonnet Studs, Nuts, Bushings, 8.--.
.~in.
.and Washers B-G-2 J
87.70,.....
2SI-01 2SI8956A
................... BLT....1..-.1.8............
Valve Bonnet Studs, Nuts, Bushings, and Washers B-G-2 l
87.70,...
... 2SI8956B
............... BILT 1-18,
Valve
. BonnetStuds,
. Nuts, and Washers.
-.1 Bushings,.,
D, G D, G B-G-2 87.70 2SI-09 2SI8956C BILT 1-18 Valve Bonnet Studs, Nuts, Bushings, and Washers B-G_2 87.70 2SI-1'3 2SI8956D..
B LT 1-18 Valve Bonnet Studs, Nuts, Bushings,
-
in
....and Washers