Text

e/_DUKE Brian C. McCabe Support Services Manager ENERGY Harris Nuclear Plant 5413 Shearon Harris Rd New Hill, NC 27562-9300 919.362.2124 February 18, 2019 Serial: RA-19-0112 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400/Renewed License No. NPF-63

Subject:

Annual Report in Accordance with Technical Specification 6.9.1.2 Ladies and Gentlemen:

In accordance with Shearon Harris Nuclear Power Plant, Unit 1 (H NP), Technical Specification 6.9.1.2, Duke Energy Progress, LLC, is providing the following information regarding reactor coolant specific activity for 2018.

During 2018, specific activity of the HNP reactor coolant did not exceed 1 microCurie per gram dose equivalent 1-131 or 100/E-bar microCuries per gram of gross radioactivity as set forth in Technical Specification 3.4.8.

This submittal contains no regulatory commitments. Please refer any questions regarding this submittal to Sarah McDaniel at (919) 362-2002.

Sincerely, fcJ C.1Yle(k Brian C. McCabe cc: J. Zeiler, NRG Sr. Resident Inspector, HNP M. Barillas, NRG Project Manager, HNP NRG Regional Administrator, Region II

Brian C. McCabe Support Services Manager Harris Nuclear Plant 5413 Shearon Harris Rd New Hill, NC 27562-9300 919.362.2124 Serial: RA-19-0112 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400/Renewed License No. NPF-63

Subject:

Annual Report in Accordance with Technical Specification 6.9.1.2 Ladies and Gentlemen:

In accordance with Shearon Harris Nuclear Power Plant, Unit 1 (HNP), Technical Specification 6.9.1.2, Duke Energy Progress, LLC, is providing the following information regarding reactor coolant specific activity for 2018.

During 2018, specific activity of the HNP reactor coolant did not exceed 1 microCurie per gram dose equivalent I-131 or 100/E-bar microCuries per gram of gross radioactivity as set forth in Technical Specification 3.4.8.

This submittal contains no regulatory commitments. Please refer any questions regarding this submittal to Sarah McDaniel at (919) 362-2002.

Sincerely, Brian C. McCabe cc: J. Zeiler, NRC Sr. Resident Inspector, HNP M. Barillas, NRC Project Manager, HNP NRC Regional Administrator, Region II