PNO-II-97-023, on 970422,Unit 2 Taken Off Line Due to Unidentified RCS Leakage TS Limit of 1 Gpm.Nrc Resident Inspector Staff Responded Onsite Prior to Unit Shutdown & Will Continue to Closely Monitor Licensee Recovery

From kanterella
(Redirected from PNO-II-97-023)
Jump to navigation Jump to search
PNO-II-97-023:on 970422,Unit 2 Taken Off Line Due to Unidentified RCS Leakage TS Limit of 1 Gpm.Nrc Resident Inspector Staff Responded Onsite Prior to Unit Shutdown & Will Continue to Closely Monitor Licensee Recovery
ML15239A405
Person / Time
Site: Oconee 
Issue date: 04/22/1997
From: Carroll R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
PNO-II-97-023, PNO-II-97-23, NUDOCS 9704230245
Download: ML15239A405 (2)


0 CATEGORY I REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9704230245 DOC.DATE: 97/04/22 NOTARIZED: NO DOCKET #

FACIL:50-270 Oconee Nuclear Station, Unit 2, Duke Power Co.

05000270 AUTH.NAME AUTHOR AFFILIATION CARROLL,R.

Region 2 (Post 820201)

RECIP.NAME RECIPIENT AFFILIATION

SUBJECT:

PNO-II-97-023:on 970422,Unit 2 taken off line due to unidentified RCS leakage TS limit of 1 gpm.NRCresident inspector staff responded onsite prior to unit shutdown &

will continue to closely monitor licensee recovery.

DISTRIBUTION CODE: IE34F COPIES RECEIVED:LTR 0 ENCL SIZE:

TITLE: 50 Docket & Vendors PNO/Non-Routine Event/Safeguards Event (PN)

NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL C

INTERNAL: ACRS 1

c 1

NRR/DISP/PIPB 1

NRR/DRPM/PERB 1

NUDOCS FULL TXT 1

OE DIR 1

RES/DET/EIB 1

RES/DRA 1

RES/DRA/DEPY 1

RES/DST 1

RES/DSTDEPY 1

RES/RPHEB 1

RGN2 FILE 01 1

EXTERNAL: LITCO BRYCE,J H 1

NOAC 1

NRC PDR 1

C C

T

'I NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE.

TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 0

TOTAL NUMBER OF COPIES REQUIRED: LTTR

.& ENCL 16 April 22, 1997 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE PNO-II-97-023 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verification or evaluation, and is basically all that is known by Region II staff in Atlanta, Georgia on this date.

Facility Licensee Emergency Classification Duke Power Co.

Notification of Unusual Event Oconee 2 Alert Seneca,South Carolina Site Area Emergency.

Dockets: 50-270 General Emergency X Not Applicable

Subject:

EXTENDED SHUTDOWN -

OCONEE UNIT 2 On.April 22, 1997, at 12:50 p.m., Oconee Unit 2 was taken off line due to unidentified reactor coolant system (RCS) leakage exceeding the Technical Specification limit of 1 gpm. From the time of initial leak indications (April 21, at 10:45 p.m.) until taking the Unit off line, leakage went from approximately 2 gpm to 9 gpm. A containment entry at approximately 20-percent power identified the source of leakage to be in the area of the high pressure injection line associated with reactor coolant loop 2A1.

Once shutdown, current plans are to take the Unit-to cold shutdown to effect necessary repairs. Unit restart is not expected earlier than late this week.

The NRC'resident inspector staff responded onsite prior to Unit shutdown and will continue to closely monitor the licensee's recovery activities.

The State of South Carolina has been notified. The licensee is prepared to respond to any media inquiries, but no press release is planned.

This information is current as of 3:00 p.m., on April 22, 1997.

Contact:

R. CARROLL (404)331-5543 9704230245 970422 PDR I&E PNO-II-97-023 PDR