NRC Generic Letter 80-99, Technical Specification Revisions For Snubber Surveillance

From kanterella
Jump to navigation Jump to search

text

WASHINGTON, D. C. 20555 November 20, 1980

TO ALL POWER REACTOR LICENSEES (EXCEPT SEP LICENSEES)

RE: TECHNICAL SPECIFICATION REVISIONS FOR SNUBBER SURVEILLANCE

Enclosed is a copy of Revision 1 of the Inservice Surveillance Requirements for snubbers under the Standard Technical Specifications. This revision embodies several changes, clarifications, and improvements from the previous version based on recent operating experience. This revision also includes surveillance requirements for mechanical snubbers.

We request that you submit a license amendment application to incorporate the applicable portion of these model Technical Specifications into your Appendix "A" Technical Specification within the next 120 days.

In case you have questions, please contact H. Shaw, 492-7364.

Sincerely,

Darrell G. Eisenhut, Director Division of Licensing

Enclosure:

Standard Technical Specifications Snubber Surveillance Requirements

cc w/encl. for information:

See Service List SEP Licensees