WASHINGTON, D. C. 20555 November 20, 1980
TO ALL POWER REACTOR LICENSEES (EXCEPT SEP LICENSEES)
RE: TECHNICAL SPECIFICATION REVISIONS FOR SNUBBER SURVEILLANCE
Enclosed is a copy of Revision 1 of the Inservice Surveillance Requirements for snubbers under the Standard Technical Specifications. This revision embodies several changes, clarifications, and improvements from the previous version based on recent operating experience. This revision also includes surveillance requirements for mechanical snubbers.
We request that you submit a license amendment application to incorporate the applicable portion of these model Technical Specifications into your Appendix "A" Technical Specification within the next 120 days.
In case you have questions, please contact H. Shaw, 492-7364.
Sincerely,
Darrell G. Eisenhut, Director Division of Licensing
Enclosure:
Standard Technical Specifications Snubber Surveillance Requirements
cc w/encl. for information:
See Service List SEP Licensees