H Nebraska Public Power District Always there when you need us NLS2012119 November 1, 2012 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001

Subject:

Notification of Changes to Cooper Nuclear Station Emergency Response Data System Data Point Library Cooper Nuclear Station, Docket No. 50-298, DPR-46

Dear Sir or Madam:

In accordance with the requirements of 10 CFR 50, Appendix E, Section VI.3.a, Nebraska Public Power District is submitting this letter to provide notification of revisions to the Cooper Nuclear Station Emergency Response Data System (ERDS) Data Point Library (DPL). Nuclear Regulatory Commission (NRC) notification of these changes is required within 30 days.

A new meteorological tower was installed and implemented on October 31, 2012, that prompted a review of applicable points in the ERDS DPL. This review determined that the DPL point for WIND SPEED, lOOM LVL WIND SPEED, did not contain an appropriate Alarm/Trip Set Point.

Therefore, it was modified to reflect an Alarm/Trip Set Point consistent with the installed equipment.

During this review, the calculation for STAB CLASS, AIR STABILITY CLASS AT lOOM, was identified as being incorrect and was also corrected. The STAB CLASS point calculation now determines the parameter value based on the differential temperature between the 10 meter level and 100 meter level instruments. This calculation correction was completed on October 3, 2012.

As a result of a review of the DPL, several other changes were made to reflect the configuration of the feeds to the ERDS system. These changes primarily reflect changes in alarm set points that have been implemented. The affected points in the DPL include the following:

" NI SOURC RNG, AVERAGE SRM (SOURCE RANGE)

  • EFF GAS RAD, ELEVATED RELEASE POINT RADIATION LEVEL
  • DW RAD, AVERAGE DRYWELL RADIATION
  • MN STEAM RAD, AVERAGE MS RAD LEVEL We have also taken the opportunity to reformat the entire document. This document supersedes the previous DPL in its entirety.

COOPER NUCLEAR STATION P.O. Box 98 / Brownville, NE 68321-0098 Telephone: (402) 825-3811 / Fax: (402) 825-5211 www.nppd.com

NLS2012119 Page 2 of 2 This letter contains no new regulatory commitments. Should you have any questions regarding this submittal, please contact me at (402) 825-2904.

Sincerely, David W. Van Der Kamp Licensing Manager

/lb

Enclosure:

Cooper Nuclear Station ERDS Data Point Library cc:

Regional Administrator w/enclosure USNRC - Region IV Cooper Project Manager w/enclosure USNRC - NRR Project Directorate IV-1 Senior Resident Inspector w/enclosure USNRC - CNS NPG Distribution w/o enclosure CNS Records w/enclosure

NLS2012119 Enclosure COOPER NUCLEAR STATION ERDS DATA POINT LIBRARY

Cooper Nuclear Station ERDS Data Point Library Page 1 of 35 Prepared By:,

Reviewed By: 62~ ~?&~-

Date: /e-5 0-/Z-Date: /0 -?I-2-o) Z Date: /0--3/-c o IO, a

Approved By:

q 1 4l it.,

A,(ý Effective Date:

EtI 1,,

Cooper Nuclear Station ERDS Data Point Library Page 2 of 35 LIST of Effective Pages NI POW ER RNG..........................................................................................................................................................

3 NI INTER RNG.............................................................................................................................................................

4 NI SOURC RNG............................................................................................................................................................

5 REAC VES LEV.............................................................................................................................................................

6 M AIN FD FLOW..........................................................................................................................................................

7 RCIlC FLOW.................................................................................................................................................................

8 RCS PRESSURE............................................................................................................................................................

9 HPCI FLOW...............................................................................................................................................................

10 LPCIL FLOW................................................................................................................................................................

11 CRSPRAYFL..............................................................................................................................................................

12 DW FD SM P LV.........................................................................................................................................................

13 EFF GAS RAD............................................................................................................................................................

14 EFF LIQ RAD..............................................................................................................................................................

15 CND A/E RAD............................................................................................................................................................

16 DW RAD....................................................................................................................................................................

17 M N STEAM RAD.......................................................................................................................................................

18 DW PRESS.................................................................................................................................................................

19 DW TEM P.................................................................................................................................................................

20 SP TEM P...................................................................................................................................................................

21 SP LEVEL...................................................................................................................................................................

22 H2 CONC...................................................................................................................................................................

23 02CONC..................................................................................................................................................................

24 CST LEVEL.................................................................................................................................................................

25 W IND SPEED.............................................................................................................................................................

26 W IND DIR.................................................................................................................................................................

27 STAB CLASS...............................................................................................................................................................

28 RHR FLOW A.............................................................................................................................................................

29 RHR FLOW B.............................................................................................................................................................

30 CS FLOW A................................................................................................................................................................

31 CS FLOW B................................................................................................................................................................

32 CRD FLOW................................................................................................................................................................

33 EM G CST A................................................................................................................................................................

34 EM G CST B................................................................................................................................................................

35

Cooper Nuclear Station ERDS Data Point Library Page 3 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO1 N/A NI POWER RNG NI POWER RNG AVERAGE APRM (POWER RANGE)

NI, POWER RANGE A

N/A 0.0 125.0 N/A N/A P

6 AVERAGE IN REACTOR CORE HIGH ALARM AT 118% FOR RUN MODE N/A N/A LAST VALID VALUE N/A N/A HIGH ALARM AT 118% DURING RUN MODE. HIGH ALARM AT 14% FOR STARTUP, REFUEL, AND SHUTDOWN MODES.

Cooper Nuclear Station ERDS Data Point Library Page 4 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 NI INTER RNG NOT CURRENTLY AVAILABLE

Cooper Nuclear Station ERDS Data Point Library Page 5 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

10/03/12 COl N/A NI SOURC RNG NI SOURC RNG AVERAGE SRM (SOURCE RANGE)

NI, SOURCE RANGE A

CPS N/A 0.1 1,000,000 N/A N/A P

4 AVERAGE IN REACTOR CORE 400,000 CPS IN STARTUP MODE N/A N/A LAST VALID VALUE N/A N/A SENSORS RETRACTED WHEN MODE SWITCH IS SWITCHED TO RUN POSITION. ALARM SETPOINTS ARE 700,000 IN RUN, 400,000 IN STARTUP, 500 IN REFUEL AND SHUTDOWN.

Cooper Nuclear Station ERDS Data Point Library Page 6 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

10/03/12 COl N/A REAC VES LEV REAC VES LEV REACTOR VESSEL WATER LEVEL REACTOR VESSEL WATER LEVEL A

IN N/A

-150.0 225.0 TAF TOP OF FUEL = 0" P

6 AVERAGE OF VALID RANGE INSTRUMENTATION LINES TO REACTOR VESSEL LOW ALARM AT 165" N/A N/A LAST VALID VALUE YES WET ALARM LOW LEVEL AT 165", WARNING LOW LEVEL AT 185.5",

WARNING HIGH LEVEL AT 200.5". ALL LEVELS ARE IN REFERENCE TO THE TOP OF ACTIVE FUEL. NARROW RANGE INSTRUMENTS PROVIDE DATA DOWN TO 158". WIDE RANGE INSTRUMENTS PROVIDE DATA DOWN TO 3". FUEL ZONE INSTRUMENTS PROVIDE DATA BELOW THIS LEVEL. FUEL ZONE LOW ALARM IS AT TAF. FUEL ZONE INSTRUMENT IS NOT TEMPERATURE COMPENSATED.

Cooper Nuclear Station ERDS Data Point Library Page 7 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO1 N/A MAIN FD FLOW MAIN FD FLOW MAIN CONDENSATE FLOW FEEDWATER FLOW INTO REACTOR SYS A

GPM N/A 0.0 25000.0 N/A N/A S

1 N/A CONDENSATE PMP DISCHARGE LINE N/A N/A N/A LAST VALID VALUE YES N/A

Cooper Nuclear Station ERDS Data Point Library Page 8 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO1 N/A RCIC FLOW RCIC FLOW RCIC FLOW RCIC FLOW A

GPM N/A 0.0 500.0 N/A N/A S

1 N/A RCIC PUMP DISCHARGE LINE, NE QUAD N/A N/A N/A LAST VALID VALUE YES N/A

Cooper Nuclear Station ERDS Data Point Library Page 9 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 Col N/A RCS PRESSURE RCS PRESSURE AVERAGE RPV PRESSURE REACTOR COOLANT SYSTEM PRESSURE A

PSIG N/A 0.0 1500.0 N/A N/A P

2 AVERAGE INSTRUMENT LINES FROM REACTOR VESSEL HIGH PRESSURE AT 1035 PSIG N/A N/A LAST VALID VALUE N/A N/A HIGH PRESSURE AT 1035 PSIG FOR RUN AND STARTUP MODES. HIGH PRESSURE AT 75 PSIG FOR REFUEL AND SHUTDOWN MODES. NOTE:

THIS POINT IS AVERAGE RPV PRESSURE.

Cooper Nuclear Station ERDS Data Point Library Page 10 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 Col N/A HPCI FLOW HPCI FLOW HPCI FLOW HPCI FLOW A

GPM N/A 0.0 5000.0 N/A N/A S

1 N/A HPCI PUMP DISCHARGE LINE, SW QUAD LOW FLOW AT 400 GPM N/A N/A LAST VALID VALUE YES N/A

Cooper Nuclear Station ERDS Data Point Library Page 11 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO1 N/A LPCI FLOW LPCI FLOW RHR A & B LOOP COMBINED FLOW LPCI FLOW A

GPM N/A 0.0 40000.0 N/A N/A P

2 SUM RHR PUMP DISCHARGE LINES, NW & SW QUAD N/A N/A N/A SUM OF LAST VALID VALUES YES N/A THIS VALUE REPRESENTS THE TOTAL FLOW OF BOTH LOOPS OF RHR SYSTEM. EACH LOOP OF THE RHR SYSTEM OPERATES IN ONE OF FOUR MODES: LOW PRESSURE COOLANT INJECTION (LPCI), CONTAINMENT COOLING, SHUTDOWN COOLING, OR HOT STANDBY. THE TWO LOOPS OF THE RHR SYSTEM CAN OPERATE IN SEVERAL DIFFERENT COMBINATIONS OF THESE MODES.

Cooper Nuclear Station ERDS Data Point Library Page 12 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 COl N/A CR SPRAY FL CR SPRAY FL CORE SPRAY LOOP A & LOOP B COMBINED FLOW CORE SPRAY COOLING SYSTEM FLOW A

GPM N/A 0.0 12000.0 N/A N/A P

2 SUM CS PUMP DISCHARGE LINES, NE & SE QUAD N/A N/A N/A SUM OF LAST VALID VALUES YES N/A

Cooper Nuclear Station ERDS Data Point Library Page 13 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 COl N/A DW FD SMP LV DW FD SMP LV DRYWELL FLOOR DRAIN SUMP LEVEL ALARM DRYWELL FLOOR DRAIN SUMP LEVEL D

HIGH=1 NML=O N/A 0

1 N/A N/A S

1 N/A F SUMP IN LOWER LEVEL OF DRYWELL N/A N/A N/A LAST VALID VALUE N/A N/A

Cooper Nuclear Station ERDS Data Point Library Page 14 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

10/03/12 COl N/A EFF GAS RAD EFF GAS RAD ELEVATED RELEASE POINT RADIATION LEVEL RADIOACTIVITY OF RELEASED GASSES A

UCI/S N/A 0.01 1.00E12 N/A N/A S

2 PROGRAM PICKS SENSOR WITH VALID RANGE ON ERP DISCHARGE LINE IN OFF-GAS HOUSE HIGH ALARM AT 728,000 UCI/S N/A N/A LAST VALID VALUE N/A N/A

Cooper Nuclear Station ERDS Data Point Library Page 15 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

05/11/92 COl N/A EFF LIQ RAD EFF LIQ RAD EFF RAD RAD RADIOACTIVITY OF RELEASED LIODS A

UC/CC N/A 1.OOE-6 1.00E-1 N/A N/A S

1 N/A LIQ RAD WSTE DISCHRG LINE, RAD WSTE BLDG N/A N/A N/A LAST VALID VALUE N/A N/A LIQUID RADWASTE DISCHARGE LINE FLOW IS 70 GPM WITH THE SENSING LINE FLOW ADJUSTED TO GREATER THAN 3 GPM AT THE START OF EACH DISCHARGE.

Cooper Nuclear Station ERDS Data Point Library Page 16 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 COl N/A CND A/E RAD CND A/E RAD SJAE AVERAGE RADIATION LEVEL CONDENSER A/E RADIOACTIVITY A

MR/HR N/A 1.0 1.000E6 N/A N/A P

2 AVERAGE DISCHARGE LINE OF SJAE, TURBINE BLDG HIGH LEVEL AT 1585 MR/HR N/A N/A LAST VALID VALUE N/A N/A

Cooper Nuclear Station ERDS Data Point Library Page 17 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

10/03/12 COl N/A DW RAD DW RAD AVERAGE DRYWELL RADIATION RADIATION LEVEL IN THE DRYWELL A

R/HR N/A 1.0 1.000E7 N/A N/A P

2 AVERAGE 1st LEVEL IN DRYWELL N/A N/A N/A LAST VALID VALUE N/A N/A PLANT OPERATIONS WILL BASE DECISIONS AT THE FOLLOWING VALUES:

115 R/HR INDICATES LOSS OF CLAD IF NO LOCA.

240 R/HR INDICATES LOSS OF RCS BARRIER IF CLAD INTACT.

2500 R/HR INDICATES LOSS OF RCS AND FUEL CLAD BARRIERS.

TRANSMITTED POINT QUALITY IS NOT AFFECTED BY THESE VALUES.

Cooper Nuclear Station ERDS Data Point Library Page 18 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

10/03/12 COl N/A MN STEAM RAD MN STEAM RAD AVERAGE MS RAD LEVEL RADIATION LEVEL MAIN STEAM LINES A

MR/HR N/A 1.0 1.000E6 N/A N/A P

4 AVERAGE ON MS LINES IN STEAM TUNNEL N/A N/A N/A LAST VALID VALUE N/A N/A THIS VALUE REPRESENTS THE AVERAGE RADIATION LEVEL OF THE FOUR MAIN STEAM LINES. EACH MAIN STEAM LINE RADIATION MONITOR HAS AN ALARM POINT. A MSL HI-HI = 1.08E+03, B MSL HI-HI = 9.94E+02, C MSL HI-HI = 1.08E+03, D MSL HI-HI = 8.98E+02.

TRANSMITTED POINT QUALITY IS NOT AFFECTED BY THESE VALUES.

Cooper Nuclear Station ERDS Data Point Library Page 19 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 COl N/A DW PRESS DW PRESS AVERAGE DRYWELL PRESSURE DRYWELL PRESSURE A

PSIG N/A

-5.0 70.0 N/A N/A P

2 AVERAGE INSTRUMENT LINES FROM 2nd LEVEL DRYWELL HIGH PRESSURE AT 1.8 PSIG N/A N/A LAST VALID VALUE N/A N/A

Cooper Nuclear Station ERDS Data Point Library Page 20 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO1 N/A DW TEMP DW TEMP AVERAGE DRYWELL TEMPURATURE DRYWELL TEMPURATURE A

DEGF N/A 0.0 400.0 N/A N/A P

20 WEIGHTED AVERAGE VARIOUS LOCATIONS IN DRYWELL HIGH TEMPERATURE AT 150 DEG F N/A N/A LAST VALID VALUE N/A N/A

Cooper Nuclear Station ERDS Data Point Library Page 21 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 Col N/A SP TEMP SP TEMP OVERALL AVERAGE SUPP POOL TEMP SUPPRESSION POOL TEMPERATURE A

DEGF N/A 0.0 250.0 N/A N/A P

16 AVERAGE BOTTOM OF SUPPRESSION POOL HIGH TEMPERATURE AT 95 DEG F N/A N/A LAST VALID VALUE N/A N/A

Cooper Nuclear Station ERDS Data Point Library Page 22 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO1 N/A SP LEVEL SP LEVEL SUPPRESSION POOL WATER LEVEL SUPPRESSION POOL WATER LEVEL A

FEET N/A 0.00 30.00 TNKBOT BOTTOM OF SUPPRESSION POOL = 0 FEET P

2 AVERAGE IN SUPPRESSION POOL HIGH LEVEL ALARM AT 12.90 FEET N/A N/A LAST VALID VALUE YES WET

Cooper Nuclear Station ERDS Data Point Library Page 23 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

Nl Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 Col N/A H2 CONC H2 CONC HYDROGEN CONCENTRATION IN DRYWELL/TORUS DRYWELL/TORUS HYDROGEN CONC A

%H2 N/A 0.00 30.00 N/A N/A S

4 N/A 3 SAMPLE LINES TO DRYWELL AND 1 TO TORUS HIGH ALARM AT 1%

N/A N/A LAST VALID VALUE N/A N/A THIS VALUE COMES FROM A ROTATION OF 4 DIFFERENT SAMPLE POINTS, 3 IN THE DRYWELL AND 1 IN THE TORUS. EVERY 10 MINUTES THE VALUE ROTATES TO THE NEXT POINT. THE VALUES ARE FROM DIV II OF THIS SYSTEM.

Cooper Nuclear Station ERDS Data Point Library Page 24 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 COl N/A 02 CONC 02 CONC OXYGEN CONCENTRATION IN DRYWELL/TORUS DRYWELL/TORUS OXYGEN CONC A

%02 N/A 0.00 30.00 N/A N/A S

4 N/A 3 SAMPLE LINES TO DRYWELL AND 1 TO TORUS HGH ALRM 3.9% DURING RUN & STRTUP MODES N/A N/A LAST VALID VALUE N/A N/A THIS VALUE COMES FROM A ROTATION OF 4 DIFFERENT SAMPLE POINTS, 3 IN THE DRYWELL AND 1 IN THE TORUS. EVERY 10 MINUTES THE VALUE ROTATES TO THE NEXT POINT. THE VALUES ARE FROM DIV II OF THIS SYSTEM.

Cooper Nuclear Station ERDS Data Point Library Page 25 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO1 N/A CST LEVEL CST LEVEL CONDENSATE STORAGE TANK A LEVEL CONDENSATE STORAGE TANK LEVEL A

PERCENT EACH 1% = 4500 GALLONS 0.0 100.0 TNKBOT BOTTOM OF DISCHARGE PIPE = 0%

S 1

N/A SOUTH YARD, CST 1A DISCHARGE PIPE LEVEL LOW LEVEL ALARM AT 25%

N/A N/A LAST VALID VALUE N/A DRY THIS IS A 450,000 GALLON STORAGE TANK.

Cooper Nuclear Station ERDS Data Point Library Page 26 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

10/03/12 COl N/A WIND SPEED WIND SPEED 100M LVL WIND SPEED WIND SPEED AT THE REACTOR SITE A

MPH N/A 0.0 100.0 N/A N/A S

1 N/A 100M POSITION OF METEROLOGICAL TOWER 100 MPH HIGH WIND SPEED N/A N/A LAST VALID VALUE N/A N/A SENSOR IS LOCATED AT lOOM LEVEL ON METEROLOGICAL TOWER.

THE RELEASE POINT OF THE ERP TOWER IS lOOM. VALUE IS INSTANTANEOUS.

Cooper Nuclear Station ERDS Data Point Library Page 27 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO1 N/A WIND DIR WIND DIR lOOM LVL WIND DIRECTION WIND DIRECTION AT REACTOR SITE A

DEGFR N/A 0

360 N/A N/A S

1 N/A 100M LOCATION OF METEROLOGICAL TOWER N/A N/A N/A LAST VALID VALUE N/A N/A THIS SENSOR IS LOCATED AT lOOM LEVEL OF METEROLOGICAL TOWER. THE RELEASE LEVEL FOR THE ERP TOWER IS 100M. 0 DEGREES IS NORTH, 90 DEGREES IS EAST, 180 DEGREES IS SOUTH, 270 DEGREES IS WEST.

Cooper Nuclear Station ERDS Data Point Library Page 28 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

10/03/12 COl N/A STAB CLASS STAB CLASS AIR STABILITY CLASS AT 100M AIR STABILITY AT REACTOR SITE A

STABI N/A 1

7 N/A N/A P

2 PROGRAM USING DELTA TEMPERATURE M ETEROLOGICAL TOWER N/A N/A N/A LAST VALID VALUE N/A N/A VALUES 1-7 REPRESENT STABILITY CLASSES A-G. STABILITY IS DETERMINED BY DELTA T BETWEEN 100 METER AND 10 METER ELEVATIONS.

Cooper Nuclear Station ERDS Data Point Library Page 29 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO1 N/A N/A RHR FLOW A RHR FLOW A LOOP RHR FLOW A A

GPM N/A 0.0 20000.0 N/A N/A S

1 N/A RHR PUMP A DISCHARGE LINE, NW QUAD N/A N/A N/A LAST VALID VALUE YES N/A THIS VALUE INDICATES THE FLOW OF A LOOP RHR PUMPS. EACH LOOP OF THE RHR SYSTEM OPERATES IN ONE OF FOUR MODES: LOW PRESSURE COOLANT INJECTION (LPCI), CONTAINMENT COOLING, SHUTDOWN COOLING, OR HOT STANDBY. THE TWO LOOPS OF THE RHR SYSTEM CAN OPERATE IN SEVERAL DIFFERENT COMBINATIONS OF THESE MODES.

Cooper Nuclear Station ERDS Data Point Library Page 30 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 COl N/A N/A RHR FLOW B RHR FLOW B LOOP RHR FLOW B A

GPM N/A 0.0 20000.0 N/A N/A S

1 N/A RHR PUMP B DISCHARGE LINE, SW QUAD N/A N/A N/A LAST VALID VALUE YES N/A THIS VALUE INDICATES THE FLOW OF B LOOP RHR PUMPS. EACH LOOP OF THE RHR SYSTEM OPERATES IN ONE OF FOUR MODES: LOW PRESSURE COOLANT INJECTION (LPCI), CONTAINMENT COOLING, SHUTDOWN COOLING, OR HOT STANDBY. THE TWO LOOPS OF THE RHR SYSTEM CAN OPERATE IN SEVERAL DIFFERENT COMBINATIONS OF THESE MODES.

Cooper Nuclear Station ERDS Data Point Library Page 31 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 COl N/A N/A CS FLOW A CORE SPRAY FLOW A LOOP CORE SPRAY FLOW A A

GPM N/A 0.0 6000.0 N/A N/A S

1 N/A CS PUMP A DISCHARGE LINE, NE QUAD N/A N/A N/A LAST VALID VALUE YES N/A

Cooper Nuclear Station ERDS Data Point Library Page 32 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 COl N/A N/A CS FLOW B CORE SPRAY FLOW B LOOP CORE SPRAY FLOW B A

GPM N/A 0.0 6000.0 N/A N/A S

1 N/A CS PUMP B DISCHARGE LINE, SE QUAD N/A N/A N/A LAST VALID VALUE YES N/A

Cooper Nuclear Station ERDS Data Point Library Page 33 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 CO21 N/A N/A CRD FLOW CRD SYSTEM FLOW CRD SYSTEM FLOW A

GPM N/A 0.0 160.0 N/A N/A S

1 N/A CRD PUMPS DISCHARGE LINE, REACT BLDG N/A N/A N/A LAST VALID VALUE YES N/A

Cooper Nuclear Station ERDS Data Point Library Page 34 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 Col N/A N/A EMG CST A EMERG COND STRG TK 1A LEVEL EMERG COND STRG TK 1A LEVEL A

PERCENT 1% = 500 GALLONS 0.0 100.0 TNKBOT BO-TOM OF DISCHARGE PIPE = 0%

S 1

N/A ECST ROOM, ECST 1A DISCHARGE PIPE LEVEL HIGH LEVEL AT 97%

N/A N/A LAST VALID VALUE N/A DRY THIS IS A 50,000 GALLON TANK AND IS CROSS-CONNECTED TO EMERGENCY CONDENSATE STORAGE TANK lB.

Cooper Nuclear Station ERDS Data Point Library Page 35 of 35 Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Locations:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-off Power Level:

NI Detector Power Supply Turn-on Power Level:

Instrument Failure Mode:

Temperature Compensation For DP Transmitters:

Level Reference Leg:

Unique System Desc.:

01/16/92 COl N/A N/A EMG CST B EMERG COND STRG TK 1B LEVEL EMERG COND STRG TK 1B LEVEL A

PERCENT N/A 0.0 100.0 TNKBOT BOTTOM OF DISCHARGE PIPE = 0%

S 1

N/A ECST ROOM, ECST 1B DISCHARGE PIPE LEVEL HIGH LEVEL AT 97%

N/A N/A LAST VALID VALUE N/A DRY THIS IS A 50,000 GALLON TANK AND IS CROSS-CONNECTED TO EMERGENCY CONDENSATE STORAGE TANK 1A.