Technical Letter Report
[TLR-RES/DE/REB-2024-12]
Technical Information Needs and Regulatory Considerations for Front-End Transportation Activities of HALEU Feed Material Date:
August 2024 Prepared in response to Task 1 in User Need Request NMSS-2022-002, by:
Steven J Maheras PNNL Antonio B Rigato PNNL Harold E Adkins PNNL Donald R Todd, PNNL Krista I Kaiser PNNL Stuart T Arm PNNL David J Richmond PNNL Kenneth M Thomas PNNL NRC Project Manager:
W. Reed Reactor Engineering Branch Division of Engineering Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Choose an item.
DISCLAIMER This report was prepared as an account of work sponsored by an agency of the U.S. Government.
Neither the U.S. Government nor any agency thereof, nor any employee, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for any third party's use, or the results of such use, of any information, apparatus, product, or process disclosed in this publication, or represents that its use by such third party complies with applicable law.
Choose an item.
This report does not contain or imply legally binding requirements. Nor does this report establish or modify any regulatory guidance or positions of the U.S. Nuclear Regulatory Commission and is not binding on the Commission.
Choose an item.
PNNL-33999 Technical Information Needs and Regulatory Considerations for Front-End Transportation Activities of HALEU Feed Material August 2024 Steven J Maheras Antonio B Rigato Harold E Adkins Donald R Todd Krista I Kaiser Stuart T Arm David J Richmond Kenneth M Thomas Prepared for the U.S. Nuclear Regulatory Commission Office of Nuclear Regulatory Research Under Contract DE-AC05-76RL01830 Interagency Agreement: 31310019N0001 Task Order Number: 31310022F0033
Choose an item.
DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor Battelle Memorial Institute, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.
PACIFIC NORTHWEST NATIONAL LABORATORY operated by BATTELLE for the UNITED STATES DEPARTMENT OF ENERGY under Contract DE-AC05-76RL01830 Printed in the United States of America Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831-0062; ph: (865) 576-8401 fax: (865) 576-5728 email: reports@adonis.osti.gov Available to the public from the National Technical Information Service 5301 Shawnee Rd., Alexandria, VA 22312 ph: (800) 553-NTIS (6847) email: orders@ntis.gov <https://www.ntis.gov/about>
Online ordering: http://www.ntis.gov
PNNL-33999 Technical Information Needs and Regulatory Considerations for Front-End Transportation Activities of HALEU Feed Material August 2024 Steven J Maheras Antonio B Rigato Harold E Adkins Donald R Todd Krista I Kaiser Stuart T Arm David J Richmond Kenneth M Thomas Prepared for the U.S. Nuclear Regulatory Commission Office of Nuclear Regulatory Research Under Contract DE-AC05-76RL01830 Interagency Agreement: 31310019N0001 Task Order Number: 31310022F0033 Pacific Northwest National Laboratory Richland, Washington 99354
PNNL-33999 Executive Summary iii Executive Summary The purpose of this study is to provide a comprehensive assessment of the current outlook and packaging requirements for transporting high-assay low-enriched uranium (HALEU) feed materials. Given the anticipated increase in the use and transportation of HALEU materials to support fuel production with higher enrichments, understanding the packaging requirements and regulatory frameworks is essential to assure safety and compliance. The study assessed existing transportation packaging requirements for HALEU feed materials, focusing on the regulatory frameworks in 10 CFR Part 71 and Part 73. The study covered the packaging needs for transporting HALEU feed materials, including uranium tetrafluoride and uranium hexafluoride, from enrichment or downblending facilities to fuel fabrication facilities. However, it excludes the transportation of fuel types that contain HALEU and uranium mining and milling operations. The NRC staff reviewed current package designs, technical considerations for higher enrichment levels, and regulatory requirements, and identified potential new packages or modifications to existing ones.
The assessment found that the current HALEU feed material, even enriched up 20 wt%, can be transported using existing package designs, and there are no significant technical issues for transporting the HALEU feed materials. However, there is a likely need for new packages to transport larger quantities of HALEU to support higher enrichment levels to be more efficient.
The need for new package designs or recertification of existing ones may lead to additional regulatory reviews and potential delays in HALEU fuel production.
To meet future needs, new package designs for safely transporting larger quantities of HALEU with higher enrichments must be evaluated. This involves conducting studies on criticality benchmarks, especially for uranium hexafluoride packages, assessing differences between IAEA SSR-6 and 10 CFR Part 71, and continually monitoring and evaluating international shipping regulations, safety standards, and advancements in packaging technologies as HALEU transportation evolves.
PNNL-33999 Acronyms and Abbreviations v
Acronyms and Abbreviations A2 maximum activity level of normal form radioactive material ANSI American National Standards Institute ASME American Society of Mechanical Engineers BPVC Boiler and Pressure Vessel Code CFR Code of Federal Regulations Ci Curie CoC certificate of compliance CSI criticality safety index DOE U.S. Department of Energy DOT U.S. Department of Transportation EBR-II Experimental Breeder Reactor-II HAC hypothetical accident conditions HALEU high-assay low-enriched uranium HEU highly enriched uranium IAEA International Atomic Energy Agency keff reactivity coefficient, the effective neutron multiplication factor LEU low-enriched uranium LEU+
low-enriched uranium enriched between 5 and 10 percent by weight of U-235 LWR light-water reactor MARVEL Microreactor Applications Research Validation and Evaluation MeV megaelectron volt (1.6022x10-13 joule)
NCT normal conditions of transport NNSA National Nuclear Security Administration NRC U.S. Nuclear Regulatory Commission NUREG NRC technical report QA quality assurance RG regulatory guide SARP safety analysis report for packaging SNF spent nuclear fuel SSR specific safety requirement TRISO tristructural isotropic UF4 uranium tetrafluoride UF6 uranium hexafluoride UO2 uranium dioxide wt%
weight percent ZIRCEX Hybrid Zirconium Extraction
PNNL-33999 Contents vii Contents Executive Summary................................................................................................................... iii Acronyms and Abbreviations....................................................................................................... v 1.0 Introduction..................................................................................................................... 1 2.0 HALEU Background........................................................................................................ 2 2.1 DOE HALEU Feed Production Status.................................................................. 3 2.2 DOE HALEU Feed Transportation Status............................................................ 5 3.0 Regulatory Framework.................................................................................................... 6 3.1 10 CFR Part 71, Packaging and Transportation of Radioactive Materials............ 6 3.2 10 CFR Part 73, Physical Protection of Plants and Materials............................... 7 3.3 Standard Review Plan for Transportation Packages for Spent Fuel and Radioactive Material............................................................................................ 7 3.3.1 Structural............................................................................................... 8 3.3.2 Thermal................................................................................................. 9 3.3.3 Containment.......................................................................................... 9 3.3.4 Shielding............................................................................................. 10 3.3.5 Criticality.............................................................................................. 11 3.3.6 Materials.............................................................................................. 12 3.3.7 Operating Procedures......................................................................... 12 3.3.8 Acceptance Tests and Maintenance.................................................... 13 3.3.9 Quality Assurance............................................................................... 13 3.4 Additional NRC Regulatory Guides and Standard Review Plans........................ 14 4.0 Transportation Review for HALEU Packages................................................................ 15 4.1 General Package Design Considerations........................................................... 15 4.2 Structural........................................................................................................... 17 4.3 Thermal............................................................................................................. 18 4.4 Containment...................................................................................................... 19 4.5 Shielding............................................................................................................ 20 4.6 Criticality............................................................................................................ 21 4.7 Materials............................................................................................................ 22 4.8 Operating Procedures........................................................................................ 22 4.9 Acceptance Tests and Maintenance Program.................................................... 23 4.10 Quality Assurance.............................................................................................. 23 4.11 Appendix A to NUREG-2216.............................................................................. 23 5.0 HALEU Feed Transportation......................................................................................... 24 5.1 Considerations for HALEU Feed Transportation................................................ 24 5.2 Future Transportation Packaging Needs............................................................ 25 5.3 NRC-Approved Transportation Packages.......................................................... 30
PNNL-33999 Contents viii 5.3.1 Packages with Current CoCs............................................................... 30 5.3.2 Revalidations....................................................................................... 35 6.0 Conclusions and Recommendations............................................................................. 36 7.0 References.................................................................................................................... 37
PNNL-33999 Figures and Tables ix Figures Figure 1.
HALEU Transportation Concept......................................................................... 18 Figure 2.
Gamma Activity from the Decay of U-232 from ORIGEN................................... 21 Figure 3.
Current Uranium Feed Material Flow................................................................. 25 Figure 4.
HALEU Production at Enrichment Facilities....................................................... 26 Figure 5.
Variation on HALEU Production at Enrichment Facilities.................................... 26 Figure 6.
Stopgap Scenario for Production of HALEU....................................................... 27 Figure 7.
Variation on the Stopgap Scenario for Production of HALEU............................. 28 Figure 8.
Second Variation on the Stopgap Scenario for Production of HALEU................ 28 Figure 9.
Third Variation on the Stopgap Scenario for Production of HALEU.................... 29 Figure 10.
Fourth Variation on Stopgap Scenario for Production of HALEU........................ 29 Figure 11.
Fifth Variation on Stopgap Scenario for Production of HALEU........................... 30 Tables Table 1.
Average Material Composition of EBR-II HALEU................................................. 3 Table 2.
CSI and Number of Packages that are Allowed in a Single Conveyance for the UX-30 and DN-30 Packages................................................................... 31 Table 3.
Versa-Pac VP-55 1S and 2S Cylinder Limits for UF6 Enrichment up to 20 Wt% U-235................................................................................................... 31 Table 4.
Versa-Pac VP-55 1S and 2S Cylinder Limits for UF6 with 5-inch Pipe, U-235 Enrichment up to 100 Wt%...................................................................... 31 Table 5.
Summary of Proposed DN-30X Contents........................................................... 32 Table 6.
Versa-Pac VP-55 and VP-100 Loading Limits for Uranium Materials................. 33 Table 7.
Versa-Pac VP-55 Loading Limits for Uranium Materials with Limited Hydrogenous Packing Material.......................................................................... 33
PNNL-33999 Introduction 1
1.0 Introduction The U.S. Nuclear Regulatory Commission (NRC) has tasked Pacific Northwest National Laboratory with evaluating potential challenges associated with the safe production, and transportation of high-assay low-enriched uranium (HALEU) feed material for light water reactor (LWR) accident tolerant fuel, and advanced non-LWR fuels, and determining the information needs in the context of existing regulatory frameworks and guidance. For most accident tolerant fuel applications enrichments in the range of 6 to 8 weight percent (wt%) are being proposed.
Although it may not be strictly needed for initial testing and demonstration, some advanced reactor designs will require fuel enriched close to the 20 wt% limit to achieve maximum efficiency. Current LWRs use fuel with low-enriched uranium (LEU) that have U-235 enrichments up to 5 wt%, the maximum uranium enrichment allowed in fuel assemblies under 10 CFR 50.68. Because of this 5 wt% limit, the LWR fuel cycle is designed around production and shipment of LEU fuel. This includes enrichment facilities, fuel fabrication facilities, and transportation packages used to move fissile material. Many of these systems have been designed for enrichments at or below 5 wt%.
Specifically, this report addresses the safety and regulatory considerations for the transportation of the feed material that will be used to make HALEU fuel. Primarily, this material is uranium tetrafluoride (UF4) and uranium hexafluoride (UF6), which would be shipped from an enrichment or downblending facility to a fuel fabrication facility. This could also include uranium oxide (UO2) powders derived from a downblending process. This report evaluates the current state of HALEU feed material production and transportation, along with the associated regulatory framework. Technical gaps or needs for additional guidance and information are identified in the conclusions and recommendations section.
PNNL-33999 HALEU Background 2
2.0 HALEU Background All U.S. commercial LWRs and supporting fueling infrastructure currently use uranium enriched with the isotope U-235 up to 5 wt%. This is referred to as LEU. HALEU is defined as U-235 enriched to between 5 and 20 wt% (42 U.S.C. 16281).
Several recently proposed advanced reactor designs feature the use of HALEU fuel. This decision is likely motivated by the operational safety and efficiency potential offered by a reduced core size as well as the significantly extended duration between refueling outages that could be provided. Additionally, several fuel vendors are proposing accident tolerant fuels for current LWRs that would use HALEU fuel to leverage enhanced safety and extended operations characteristics as well.
Two general methods of producing HALEU currently exist. The first method is to enrich unspoiled, naturally occurring uranium harvested from ore, which contains less than 1 wt%
U-235, to achieve the higher 5 to 20 wt% U-235 enrichment range needed. The only commercial enrichment facility operating with unspoiled material within the United States leverages gas centrifuge technology (NRC 2020d) and is currently only used to achieve up to 5.5 wt% at one location (Freels 2021). The NRC is actively engaged with American Centrifuge Operating, LLC, a wholly owned indirect subsidiary of Centrus Energy, to authorize production of HALEU at a facility known as the American Centrifuge Lead Cascade Facility located on a U.S. Department of Energy (DOE) reservation in Piketon, Ohio.1 The DOE has been increasing production at this facility to facilitate advanced reactor deployment. Laser separation technology is another option to consider, but it is still under development and has yet to be demonstrated to be able to support commercial-scale production (NRC 2020d).
The second method of producing HALEU feed material is by using an existing stockpile of highly enriched uranium (HEU), which has enrichments greater than 20 wt%, and downblending it with natural uranium or other LEU sources. However, no supply chains of HEU that will meet potential demand projections are readily available or identifiable. Additionally, the current non-defense-related HEU supply is predominantly dedicated and overcommitted to research reactor fuel production to support advanced test reactor development, tritium production, and medical isotope production, among other things. To support near-term advanced reactor development, DOE and its national laboratories are exploring producing HALEU feed material via recovery of uranium from spent nuclear fuel (SNF) from DOE research reactors using two recycling methods.
The first recycling method uses electrochemical processing to recover and polish source material feed. The second method applies the Hybrid Zirconium Extraction (ZIRCEX) process.
Either method could be used effectively to recover HEU. This feed material could then be downblended to make HALEU feed material. Electrochemical processing tends to leave more residual radioisotopes than the ZIRCEX process. Table 1 represents the expected average of HALEU feed material composition, which has been recovered from the Experimental Breeder Reactor-II (EBR-II) SNF after appropriate downblending (Vaden 2021). The ZIRCEX process will likely have lower amounts of residual radioisotopes. As discussed in Section 4.0, specific packaging challenges stem from the greater number of residual radioisotopes that exist after electrochemical processing to recover and polish source material feed.
1 Centrus Energy Corp./American Centrifuge Operating, LLC (formerly USEC Inc.) Gas Centrifuge Enrichment Facility Licensing, https://www.nrc.gov/materials/fuel-cycle-fac/usecfacility.html.
PNNL-33999 HALEU Background 3
Table 1. Average Material Composition of EBR-II HALEU (Vaden 2021)
Analyte Units Average Total U wt%
99.57 U-232 ng/gU 0.287 U-233 ng/gU 75.771 U-234 iso% U 0.169 U-235 iso% U 19.655 U-236 iso% U 0.518 U-237 pg/gU 0.316 U-238 iso% U 79.658 Zr ppm 79.47 Y
ppm 28.31 Fe ppm 181.10 Cr ppm 14.25 Mn ppm 42.84 Al ppm 74.25 Sr-90 ppb 4.49 Tc-99 ppm 0.29 Cs-135 ppm 0.03 Cs-137 ppb 6.30 Am-241 ppb 6.32 Np-237 ppm 16.32 Pu-239 ppm 81.52 Pu-240 ppm 2.30 wt% = weight percent ng/gU = nanograms per gram of uranium iso% U = isotope weight percent of total uranium pg/gU = picograms per gram of uranium ppm = parts per million ppb = parts per billion The remainder of this section summarizes the statuses of the supply of HALEU for use in advanced reactors that may be licensed under NRC authorities, with a focus on the form and chemical composition of the HALEU during transportation activities.
2.1 DOE HALEU Feed Production Status New reactor concepts that use fuel in different chemical, isotopic, and geometric forms than found in traditional LWR fuel are being developed. This includes liquid fuel-based concepts and concepts using fuel enriched up to 20 wt% (e.g., HALEU). Regalbuto (2020) describes different scenarios and drivers as of 2020. As of June 2024, there is interest in the supply of HALEU to support the DOE-funded Advanced Reactor Demonstration Projects as illustrated by statements by Senator John Barrasso, ranking member of the Senate Committee on Energy and Natural Resources, following announcement by TerraPower that attributed a 2-year delay to the TerraPower Natrium Project to the unavailability of HALEU (ENR 2022). Investment is being made within the United States to address the supply challenges across the entire spectrum of front-end activities, including mining, conversion to UF6, and production of HALEU through enrichment and recovery from existing material (WNN 2022). As one example, the DOE Office
PNNL-33999 HALEU Background 4
of Nuclear Energy is working to establish market conditions that encourage private investment in an enduring HALEU enrichment capability through offtake contracts to stock a HALEU bank as soon as possible (SAM.gov n.d.; DOE 2022; Nuclear Newswire 2022b). These efforts may lead to a future sustained supply of HALEU originating from enrichment of virgin natural uranium sources from mining, for which a Type A fissile material transportation package could be used.
This material would be transported in UF6 form from the enricher to a fuel fabricator under the existing fuel cycle paradigm. However, considering that some proposed advanced reactor technologies do not use discrete fabricated fuel, HALEU feed material transportation may occur in other forms, such as UF4, to the reactor site. This shipment would either occur directly from an enricher that deconverts the UF6 to UF4 (or other desired form) or from an intermediary that performs the deconversion. There have been several recent developments in the HALEU feed production area:
The Inflation Reduction Act includes $700 million for research, development, and production of domestic HALEU fuel (Huff 2022). The funding is available through September 30, 2026.
Request for Information Regarding Planning for Establishment of a Program to Support the Availability of HALEU for Civilian Domestic Research, Development, Demonstration, and Commercial Use (DOE 2021). As of March 22, 2024, requests for proposals have closed for the purchase of enriched and deconverted HALEU to establish a HALEU supply chain in support of advanced reactors (DOE 2024).
Centrus signs to complete HALEU demonstration in 2023 as the DOE prepares draft request for proposal (Nuclear Newswire 2022a). Centrus is expected to boost its annual production of HALEU material to 900 kg in 2024 (DOE 2023).
On December 7, 2022, DOE established the HALEU Consortium (Merrifield et al. 2022).
In 2022, the DOE announces a cost-shared award for the first-ever domestic production of HALEU for advanced nuclear reactors (DOE 2022).
With the target timelines of the Advanced Reactor Demonstration Projects and intense pressure to use U.S.-origin fissile material and supply chains, DOE and industry partners are working to immediately secure HALEU feed material before domestic HALEU enrichment capabilities reach large-scale production. This includes obtaining material from DOE derived from downblended HEU declared surplus from other needs. A 2016 accounting of HEU stocks shared by the White House (The White House 2016) summarizes the surplus material available at that time.
However, the scenario has evolved, and less material is available for downblending to HALEU and use in civilian nuclear applications (BWXT 2018). Material derived from this source, and not previously identified as spent reactor fuel, is likely to meet requirements for a Type A fissile material transportation package. Historical activities for downblending of HEU to LEU for commercial power reactor use resulted in uranyl nitrate that was transported to a fuel fabricator.
It is not known if material downblended to HALEU would be shipped in uranyl nitrate or another form.
An example of material characteristics for HALEU fuel derived from DOE excess material is found with the proposed Microreactor Applications Research Validation and Evaluation (MARVEL) reactor (DOE n.d.). MARVEL is proposed for construction at the Idaho National Laboratory under a DOE authorization basis approval process. The MARVEL Fuel Fabrication Strategy (Johnson et al. 2022) describes that the material fuel will be made in the form of metal scraps from castings obtained from Y-12 that would be transported in this form to the fuel fabricator for conversion and fabrication into fuel slugs. The report summarizes transportation
PNNL-33999 HALEU Background 5
plans to and from the fabricator via a Type B(U) fissile package and includes preliminary chemical analysis of typical HALEU materials from Y-12. The original form (metal scraps) and chemical analysis may be useful to informing other product coming from Y-12 and provided for use in civilian applications. Care must be taken in extrapolating to other materials as Y-12 has material inventory from a wide range of sources.
DOE has proposed making HALEU fuel available for microreactor demonstration by recycling existing stocks of spent fuel. Baker (2019) (INL/CON-19-54336, HALEU for Fuel Development and Microreactor Demonstration [multiple presentations including discussion of recovery of uranium from irradiated EBR-II fuel]) and Patterson (2021) provide background information for this pathway. Technical details for material that may be derived from recycled EBR-II fuel are listed in Baker (2019) (INL/CON-19-54336), including potential chemical and isotopic composition of HALEU fuel emanating from an existing electrometallurgical treatment process applied to the EBR-II fuel. This composition data is informative for what may be expected for HALEU derived from other spent fuel recycling and used in advanced reactor HALEU fuel supply.
2.2 DOE HALEU Feed Transportation Status Previously, commercially sized UF6 cylinders are limited to enrichments of 5 wt%. For example, 30B and 30C cylinders having a capacity of 2,277 kg of UF6were limited to 5 wt% enrichment.
Cylinders that were allowed higher enrichments had limited payloads. For example, the 8A cylinder is approved for transport of UF6with an enrichment of 12.5 wt%, but its capacity is 115.67 kg of uranium hexafluoride.
Eidelpes et al. (2020) discuss a path forward for the shipment of UF6enriched to greater than 5 wt% in commercially sized quantities. For example, a 30B-20 cylinder is discussed that has a goal of being able to transport up to 1,271 kg (1,4 tons) of UF6enriched to 20 wt%. This has now been approved in the DN30-X package.
Eidelpes et al. (2020) also discusses criticality benchmarking, noting that there have been over 5,000 approved International Criticality Safety Benchmark Evaluation Projects, although most uranium experiments are done with less than 5 wt% enriched or greater than 20 wt% enriched material. This potential lack of experiments in the 5-20 wt% enriched range may increase the needed conservatism in package design.
PNNL-33999 Regulatory Framework 6
3.0 Regulatory Framework The front end of the fuel cycle is regulated through multiple agencies in the United States.
These include the U.S. Department of Transportation (DOT), NRC, U.S. Coast Guard, and the relevant state agencies. Internationally, the International Atomic Energy Agency (IAEA) has established transportation regulations, and these standards inform the NRC framework. There are also packages certified under IAEA standards used in the United States in certain circumstances. However, discussion of the IAEA standards is out of scope for this report.
Because of overlap in the statutory authorities of the NRC and DOT, the two agencies signed a memorandum of understanding in 1979 regarding regulation of the transport of radioactive material (44 FR 38690 1979). The principal objective of the memorandum of understanding was to avoid conflicting and duplicative regulations and to clearly delineate the areas in which each agency establishes regulations (PHMSA 2008). The NRC regulations relevant to transport are 10 CFR Parts 71 and 73. Part 71 establishes safety regulations for packaging and transportation, and Part 73 establishes security regulations for transportation of radioactive materials.
3.1 10 CFR Part 71, Packaging and Transportation of Radioactive Materials In 10 CFR Part 71, the NRC has promulgated regulations for the packaging and transportation of radioactive material (including feed material and fuel) that align with its safety mission of protecting the public and the environment. The NRC has incorporated by reference (10 CFR 71.5) portions of the DOT regulations, enabling the NRC to inspect its licensees for compliance with DOT regulations applicable to shipper/licensees and to take enforcement actions on violations. Transportation packages can be approved to travel over road, rail, navigable waters, or air.
NRC package approval standards include general standards applicable to all packages and requirements related to the normal conditions of transport (NCT) and to hypothetical accident conditions (HAC). The package types reviewed by the NRC are described in 10 CFR 71.4 and in 49 CFR Part 173, and include:
Type AF package: A fissile material package that includes its fissile material contents.
Type B package: A package that includes radioactive contents and is used to transport highly radioactive materials, such as spent nuclear fuel. Type B packages can range in size from small containers to over 100 tons and provide shielding against radiation.
Type BF package: A fissile material package that must meet the Type B packaging test requirements and remain subcritical.
Type A package: Must comply with DOT regulations 49 CFR Part 173. The aggregate radioactivity of the contents does not exceed A1 for special form radioactive material, or A2, for normal form radioactive material.
IP Package: There are three categories of industrial packages: IP-1, IP-2, and IP-3. Each category must comply with specific requirements that ensure no identifiable release of the material to the environment during normal transportation and handling.
PNNL-33999 Regulatory Framework 7
Regardless of the package type, the design focus of any transportation package is to meet regulations for dose rate, criticality, and release. NCT (10 CFR 71.71) and HAC (10 CFR 71.73) conditions embody these concepts by requiring the package to meet various requirements via drop tests, thermal tests, and water immersion, among others. Lifting requirements and package tie-down requirements also must be met. Design specifications not contained in the regulations themselves are often found in the standard review plan issued by the NRC in technical report NUREG-2216, which cites other NUREGs and regulatory guides (RGs).
If the NRC determines that a transportation package meets 10 CFR Part 71 requirements based on submission by an applicant via a safety analysis report for packaging (SARP), a package approval, which is typically a certificate of compliance (CoC), is issued. The CoC is valid for 5 years and can be renewed. The CoC describes the packaging and its contents and incorporates design drawings, package operations, and the acceptance and maintenance program from the SARP.
3.2 10 CFR Part 73, Physical Protection of Plants and Materials In 10 CFR Part 73, NRC has promulgated regulations for the physical protection of plants and materials. Included in these regulations are requirements for the physical protection of special nuclear material including irradiated reactor fuel in transit. The objectives of the physical protection system for shipments are to minimize the potential for theft, diversion, or radiological sabotage and to facilitate the location and recovery of shipments that may come under control of unauthorized individuals.
NUREG-0561 (NRC 2013) provides detailed guidance for the physical protection of irradiated reactor fuel in transit, including route approval procedures, preplanning and coordination of shipments, advance notification of shipments, communications, arrangements with local law enforcement agencies, armed escorts, shipment logs, procedures training, and control of information. Further, NUREG-0561 (NRC 2013) presents requirements by transport mode (e.g., road, rail, and vessel), and discusses background investigations for personnel with unescorted access to SNF in transit.
3.3 Standard Review Plan for Transportation Packages for Spent Fuel and Radioactive Material NRC regulations in 10 CFR Part 71 require that radioactive material package be able to remove heat generated by radioactive decay, shield the public from radioactive particle emissions, assure nuclear subcriticality control, and mitigate the dispersion of radioactive material.
Challenges associated with transporting HALEU feed material primarily revolve around the last two requirements. Design and approval of packages within the United States can involve the application of several consensus standards and guidance, such as applicable American Society of Mechanical Engineers (ASME), American National Standards Institute (ANSI), and American Society for Testing and Materials national standards, and guidance from NRC regulatory guides.
These standards describe requirements and dictate aspects of mechanical design, material selection, fabrication (including welding), examination, testing, SARP preparation, and certification.
Packages certified to ship HALEU feed material could be approved as several different package types that have different certification requirements. For unirradiated material derived from natural enrichment the most likely types would be fissile material packages certified as Type AF or BF. If material is derived from reprocessing and/or downblending the presence of impurities
PNNL-33999 Regulatory Framework 8
and irradiated material may require a Type B package. Additionally, as a strategic measure a designer may elect to design or certify their package as a Type B to allow flexibility for future contents.
Regulatory Guide 7.9 (RG 7.9) provides a suggested format for a transportation package certification application and documenting the package evaluations to establish the safety basis (NRC 2005b). The NRC has also issued a Standard Review Plan for transportation packages in NUREG-2216 (NRC 2020a). The guidance is separated by technical discipline and submittal format. The main application areas to review are structural, thermal, containment, shielding, criticality, materials, operating procedures, acceptance testing and maintenance, and quality assurance (QA). This section discusses the Standard Review Plan chapters and their general requirements as they relate to all radioactive material transportation packages. Section 4.0 of this report further describes the specific aspects related to HALEU feed material transportation packages and makes recommendations for reviews of these packages.
3.3.1 Structural Shielding, criticality, and thermal disciplines each revolve tightly around the structural evaluation discipline for their safety basis. Approval standards in 10 CFR 71.41 state that to demonstrate compliance, the outcomes of tests specified in 10 CFR 71.71 (NCT) and 10 CFR 71.73 (HAC) must be evaluated. The component safety groups can be further divided into containment, criticality, and other safety components, as defined below.
Containment components are defined as all the components required for retaining the radioactive contents. The function of all the containment vessel and closure components is to maintain the containment boundary, so all NCT and HAC containment requirements are met.
This component safety group includes any closure lids, seals, port components, and bolts.
Stress limits differ between NCT and HAC such that meeting NCT structural performance requirements tends to be more challenging and restrictive than meeting HAC structural performance requirements. Care must be taken to differentiate containment from the definition of confinement which is sometimes found in international standards. In 10 CFR Part 72, the definition of confinement is as follows: Confinement systems encompass those systems, including ventilation, that serve as barriers between areas containing radioactive substances and the environment. This definition aligns closely with that of containment in 10 CFR Part 71.
Specifically, containment pertains to preventing releases for 10 CFR Part 71 packages (focused on any release of contents), while confinement focuses on preventing releases for 10 CFR Part 72 systems (refers to components that maintain contents in subcritical geometry).
For Type B, Category I 1 packaging, analytical methods should be used to demonstrate that the containment vessel meets the vessel design criteria presented in Subsection NB, Article NB-3000 as amended by RG 7.6 (NRC 1978). Also, in the case of closure bolts, because of their importance, applicants/developers are directed to use acceptance criteria provided in NUREG/CR-6007 (Mok et al. 1992). Limits for release of contents are specified in 10 CFR 71.51 for both NCT and HAC evaluations, for Type B packages. Demonstration of compliance with the specified limits should be in accordance with the methods laid out in ANSI N14.5-2014 (ANSI 2014). Additionally, in accordance with 10 CFR 71.61, a Type B package containing more than 105 A2 must be designed so its undamaged containment system can withstand an external water pressure of 2 MPa (290 psi) for a period of not less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> without collapse, buckling, 1 Category 1 is defined in detail in Section 4.4 on Page 20. For a comprehensive understanding, please refer to that section
PNNL-33999 Regulatory Framework 9
or in-leakage of water. This is unlikely to apply to packages containing HALEU feed material.
These packages will adhere to different QA categories, which are determined by the type of package.
Criticality components are defined as all components required in controlling nuclear criticality during transport of fissile material in the package. This component safety group includes neutron absorbers and related structures required to retain the relative position of the fissile materials and/or neutron absorbers. Type B, Category I packaging design criteria dictates that the structural evaluations and stress limits need to comply with ASME Boiler and Pressure Vessel Code (BPVC),Section III, Division 1, Subsection NG (ASME 2019a) per NUREG/CR-3854 (Fischer and Lai 1985).
Other safety components are defined as all other safety-related packaging components.
This includes both gamma and neutron shielding components (if required); secondary seals, bolts, and closures; impact limiters; and lifting lugs and tie-down devices. Type B, Category I packaging design criteria dictates that the structural evaluations and stress limits need to comply with ASME BPVC,Section VIII, Division 1 (ASME 2019c), or Section III, Division I, Subsection NF (ASME 2019b) per NUREG/CR-3854 (Fischer and Lai 1985).
ASME BPVC,Section III, Division 1, Subsection NB (ASME 2015) contains the requirements for materials, design, fabrication, examination, and testing of Class I reactor components to form acceptable design criteria for shipping containment vessels. A critical consideration is that the choice of materials is limited, and the temperature use limits are 700°F (371°C) for carbon and low alloy (ferritic) steels and 800°F (427°C) for austenitic and high alloy steels.
3.3.2 Thermal Like the structural discipline, the thermal requirements of 10 CFR Part 71 must be met before a package can be certified for the transportation of nuclear material. Packaging must be capable of withstanding intense thermal environments while preventing reconfiguration or release of the contents, maintaining dose limits, and nuclear subcriticality. Achieving this capability requires the use of construction materials that enable the package to perform in normal and accident environments. Test requirements are outlined in 10 CFR 71.71 (NCT) and 71.73 (HAC). These include ambient temperature conditions and insolation for NCT and thermal test conditions for HAC, which requires a 1,472°F (800°C) fully engulfing fire for 30 minutes. Accordingly, all safety significant components of packaging must be designed such that all containment items withstand the highest expected temperature under HAC after the entire structural impact loading sequence per NRC RG 7.9 (NRC 2005b). After the HAC structural, thermal loading, and fissile material water immersion tests on the package, a maximum leak rate of an A2 per week is permissible for Type B packages, as specified in 10 CFR 71.51(a)(2).
3.3.3 Containment The design of radioactive material packaging typically starts with the containment system, which is defined as an assemblage of all the components required to retain the nuclear and possibly radioactive contents. In general, this includes items such as the containment vessel, possible seals and port components, and closure bolts. The structural design criteria for certain package component safety groups are based on the ASME BPVC as discussed in the Structural section.
Containment design requirements for Type B, Category 1 packaging designs are used to transport radioactive materials must be developed to make sure any release of radioisotopes
PNNL-33999 Regulatory Framework 10 during postulated NCT or HAC events falls within the specified regulatory limits. Primary regulatory documents that provide the general requirements for containment are 10 CFR Part 71, and condition-specific requirements are listed in 10 CFR 71.51 and 10 CFR 71.71 for NCT and in 10 CFR 71.51 and 10 CFR 71.73 for HAC. Containment requirements are specified in 10 CFR 71.43, General standards for all packages, and 10 CFR 71.51, for Type B packages. The phrase no loss or dispersal of radioactive contents is clarified for Type B packages in 10 CFR 71.51, Additional requirements for Type B packages.
Although shipping packages are designed to contain radioactivity and to maintain their structural integrity under the most severe reasonably anticipated conditions, leak testing of a Type B package is necessary to make sure the packages are appropriately manufactured and assembled correctly and that no unacceptable leak paths have developed from subsequent use (Anderson et al. 1996). Regulations at 10 CFR 71.51 specify the limits for maximum permissible rate of release of contents for both NCT and HAC as 10-6 A2 per hour and one A2 in 1 week, respectively. Additionally, NCT testing is to be conducted at the most unfavorable conditions of external temperature (between -20°F [-29°C] and +100°F [+38°C]) and external pressure (between 25 kPa [3.5 psi] absolute and 140 kPa [20 psi] absolute).
ANSI N14.5-2014 is critical to compliance because it provides a bridge from the regulatory release rate requirement to a measurable allowable leakage rate. ANSI N14.5-2014 also provides a list and descriptions of several accepted leakage rate test methodologies (ANSI 2014). Frequently, designers/developers will select definition of the term leak-tight (ANSI N14.5-2014 defines a leakage rate of 10-7 ref-cm3/s or less as leak-tight) as a less-complex means of determining acceptance. If this is done, then establishment of a content-dependent leakage rate determination is not required.
The types of leakage rate tests performed during the package's operation include fabrication, periodic, maintenance/repair, and pre-shipment. Leakage rate tests also may be performed during design and associated verification testing. National Nuclear Security Administration (NNSA) Safety Guide (SG)-100 (NNSA 2005), which is a design and development guide for NNSA Type B packages, describes and gives examples of leak testing methods and supporting details to consider while applying ANSI N14.5-2014 (ANSI 2014).
3.3.4 Shielding Package radiation shielding design is concerned with establishing that the regulatory radiation dose rate limits on the exterior of the package are not exceeded. The same calculations that produce radiation source term evaluations for shielding analyses also are typically used to determine the heat sources used in the thermal analyses. Shielding performance requirements are listed in 10 CFR 71.47 and 10 CFR 71.51.
Regulations at 10 CFR 71.47 specify dose rate limits for packaging anticipated to be used for transport. Under NCT, the radiation dose rate does not exceed 2 mSv/h (200 mrem/h) at any point on the external surface of the package, as specified by 10 CFR 71.47, 49 CFR 173.441, and IAEA SSR-6 (IAEA 2018). The maximum dose rate at 1 meter from any external surface of the package under NCT also must not exceed 0.1 mSv/h (10 mrem/h).
The NCT dose rate limits apply to a shipping package without regard for the method of shipment. However, most packages for feed material are shipped as exclusive use as defined in 10 CFR 71.4. A maximum package external dose rate of 10 mSv/h (1,000 mrem/h) for NCT is
PNNL-33999 Regulatory Framework 11 allowed in an exclusive use shipment. The details of exclusive use limits are given in 10 CFR 71.47 (b).
The maximum dose rate at 1 meter from any external surface position of the package under HAC must not exceed 10 mSv/h (1,000 mrem/h), as specified in 10 CFR 71.51(a)(2). For HAC, the dose rate of the external package surface is assumed to be that defined by the post-accident configuration.
3.3.5 Criticality Subcriticality design and performance requirements are described in 10 CFR 71.55 through 10 CFR 71.59. Fissile material is defined in 10 CFR Part 71 as material that contains the nuclides Pu-239, Pu-241, U-233, and U-235. Criticality safety is the practice of making sure adequate protection is provided against an accidental self-sustaining or divergent fission chain reaction. The criticality state of a system (subcritical, critical, or supercritical) often is discussed in terms of an effective neutron multiplication factor, K effective (keff), which is defined as the ratio of the neutron production rate to the neutron loss rate in the system. For the system to remain subcritical, keff must be less than one.
The conditions prescribed by the regulations require computational evaluations that incorporate statistical techniques to model neutron transport and predict keff for the system. Calculational biases and uncertainties are also part of this determination. The margin of subcriticality allowed for a package configuration must include the effect of these biases and uncertainties, together with design uncertainties, and an additional subcritical margin that would provide subcriticality for all credible transport scenarios even in the absence of all uncertainties.
Generally, criticality control is provided by geometric spacing and strategic poisoning. As such, these factors are always considered to be safety significant and should be demonstrated to remain intact during NCT as well as HAC evaluation scenarios. Another factor in criticality analysis is the potential for water in-leakage to provide a moderator to the package. To account for this effect, flooded conditions must be analyzed, or the package containment must be proven to exclude moderator entry.
Restriction of fissile mass or use of a favorable geometry to provide enhanced neutron leakage from the package as a means of controlling the neutron balance are not always feasible for establishing a packaging convention capable of supporting commercial-scale transport needs.
Instead, strategic incorporation of neutron poison materials and moderators is the primary means of controlling neutron multiplication for some fissile material contents. Neutron poisons added to the package design require special attention because their presence must be certain under all conditions and because their incorporation may change the mechanical and/or thermal properties of host materials. Additionally, the geometry of heterogeneous fissile material (e.g., tristructural isotropic fuel compacts), the design and placement of absorber materials, and the separation between fissile materials are all important to the criticality evaluation.
Regardless of the control mechanism, an adequate margin of subcriticality must be demonstrated for both the single package in isolation and for arrays of packages that might be required for economic commercial-scale transport. Undamaged (NCT) and damaged (after accident conditions [HAC]) packages must be considered using the credible fissile material configuration and the moderator and reflector conditions that provide the maximum effective neutron multiplication factor, keff.
PNNL-33999 Regulatory Framework 12 Criticality safety evaluations must be performed in establishing the safety basis of the packaging definition to demonstrate that the package will remain in a subcritical condition under NCT (see 10 CFR 71.71) and HAC (see 10 CFR 71.73). Domestic and international regulations require that a single, water-flooded package be adequately subcritical in both the undamaged and damaged condition. Regulations at 10 CFR 71.55 describes the specific domestic requirements that must be met for a single package to be certified to carry fissile material, including requirements for fissile material package designs to be transported by air (10 CFR 71.55(f)).
The undamaged package is considered to be the physical condition of the package under NCT whereas the damaged package refers to the physical condition of the package following its exposure to the tests for HAC. All internal voided volumes of the package, including the containment vessel, must be assumed to be filled with optimum water moderation for this evaluation unless moderator exclusion is successfully established as the foundation of the safety basis. The fissile material contents used in the evaluation must also be in the most reactive credible condition consistent with NCT and HAC. All forms of hydrogenous moderation are intended for consideration in determining the optimum moderation (i.e., moderation conditions for highest keff value).
Regulations state that the criticality safety evaluation must include an analysis to determine whether the portion of the package defined as the containment system, if closely reflected by water, would have a greater reactivity (higher keff) than the package when submerged in water.
If the package and containment system are not the same (e.g., 30B or 30C canister and UX-30 overpack), then two analyses must be done for the package in its undamaged conditionan analysis with a water-flooded and water-reflected containment system separate from the package and an analysis with a water-flooded and water-reflected package. The results from these two system analyses should be compared to select the one with the highest keff as the limiting case for the certification process. In short, the packaging review must evaluate all possible moderation and reflection configurations as part of establishing and verifying the safety basis.
3.3.6 Materials The materials evaluation is interrelated with many other safety analyses, including thermal, structural, and containment. This evaluation interacts with these other chapters in both directions because it determines whether the materials used in package construction will be adequate for performing their safety function and considers requirements for structural, thermal, and shielding performance when evaluating the materials. Additionally, there must be no adverse interactions caused by material type or construction. The materials are evaluated for NCT and HAC conditions. In general, high-temperature performance is a critical factor in HAC.
In NCT, this is not as impactful unless the contents generate a lot of decay heat. The materials evaluation also includes a review of weld design and the inspection of those welds. These factors feed into the containment evaluation along with seal and bolt materials.
3.3.7 Operating Procedures The operating procedures evaluation covers the loading and unloading procedures for packages. This evaluation assures that safety is maintained during loading and unloading, the package is properly prepared for shipment in accordance with its safety basis, and inspections and tests are sufficient to make sure the packaging will perform as required. An essential focus of this review is making sure that the closure and containment systems will perform as
PNNL-33999 Regulatory Framework 13 necessary and required by the other technical disciplines. This might include bolt torques, valve tests and set points, seal inspections, and leak-tightness inspections.
3.3.8 Acceptance Tests and Maintenance The acceptance tests and the maintenance procedure review are designed to evaluate the procedures used to determine whether package materials and construction are adequate to perform their safety and design functions. Acceptance tests are required to verify all the performance requirements, including structural, thermal, containment, shielding, and criticality.
This verifies that the fabrication of the package was appropriate. For the maintenance evaluation, the applicant must make sure that long-term performance of the package materials and construction is managed appropriately. This may be through inspections and/or scheduled maintenance and replacement of components.
3.3.9 Quality Assurance Quality assurance throughout the design process is as important to the successful certification of a package as to the packages ability to successfully complete the regulatory testing and verification of the safety basis (simulated or physical). DOE and NRC certifying bodies require applicants for packaging certification and shipment to adhere to 10 CFR Part 71, Subpart H requirements.
A description requirement to partially address the QA requirements in 10 CFR 71.31 is to identify established codes and standards proposed for use in the package design, materials of fabrication, fabrication, assembly, testing, maintenance, and use. In the absence of codes, standards, and applicable code cases, the basis and rationale used to formulate the QA program need to be described in adequate detail and justified to the regulator.
A quality assurance plan developed for the program should address all 18 elements required and identify the procedures that will be used to achieve the applicable development quality requirements for the packaging definition. The quality assurance plan should be developed, submitted to the certifying regulatory body for approval, and available for direct application prior to the initiation of the design and development effort.
Quality assurance specialists should have experience with packaging regulations, DOE orders, and national and international standards relating to QA in addition to 10 CFR Part 71, Subpart H requirements. The applicants QA program should detail their approach to the control of purchased items and services to fulfill the requirements of 10 CFR 71.115, Control of purchased material, equipment, and services, and 71.109, Procurement document control. Vendors should be carefully selected based on their capability to comply with applicable sections of 10 CFR Part 71, Subpart H, their facility and QA program, and their previous records and performance.
Also, all activities related to fabrication should be documented in a SARP and conducted under a certifying regulatory bodys approved QA program.
The NRC published RG 7.10 Revision 3 (NRC 2015) to provide individuals subject to the QA requirements of 10 CFR Part 71, Subpart H guidance on developing QA programs for implementation with respect to the transport of radioactive materials in Type B and fissile material packaging, such as those potentially required for HALEU feed material and HALEU fuel transport. Regulatory Guide 7.10 establishes a graded quality safety category system that delineates packaging definition items between (1) critical to safe operation, (2) has a major influence on safety, and (3) only has a minor influence on safety.
PNNL-33999 Regulatory Framework 14 Radiation shielding evaluation aspects, all physical testing initiatives, leakage rate testing, and instrument calibration also need to be performed in accordance with a written and accepted QA program and quality assurance plan that conform with the applicable requirements of 10 CFR Part 71, Subpart H, and other relevant codes and standards. Additionally, measures must be established to ensure that test results are documented, evaluated, and maintained as QA records to meet the requirements of 10 CFR 71.123.
3.4 Additional NRC Regulatory Guides and Standard Review Plans NRC regulatory guides provide direction to licensees and applicants on implementing specific parts of the NRC regulations, techniques used by the NRC staff in evaluating specific problems or postulated accidents, and data needed by the staff in its review of applications for permits or licenses. Regulatory guides specific to transportation include:
RG 7.4, Revision 1, Leakage Tests on Packages for Shipment of Radioactive Materials (NRC 2020b).
RG 7.6, Revision 1, Design Criteria for the Structural Analysis of Shipping Cask Containment Vessels (NRC 1978).
RG 7.7, Revision 1, Administrative Guide for Verifying Compliance with Packaging Requirements for Shipments of Radioactive Materials (NRC 2012).
RG 7.8, Revision 1, Load Combinations for the Structural Analysis of Shipping Casks for Radioactive Material (NRC 1989).
RG 7.9, Revision 2, Standard Format and Content of Part 71 Applications for Approval of Packages for Radioactive Material (NRC 2005b).
RG 7.10, Revision 3, Establishing Quality Assurance Programs for Packaging Used in Transport of Radioactive Material (NRC 2015).
RG 7.11, Fracture Toughness Criteria of Base Material for Ferritic Steel Shipping Cask Containment Vessels with a Maximum Wall Thickness of 4 Inches (0.1 m) (NRC 1991a).
RG 7.12, Fracture Toughness Criteria of Base Material for Ferritic Steel Shipping Cask Containment Vessels with a Wall Thickness Greater than 4 Inches (0.1 m) But Not Exceeding 12 Inches (0.3 m) (NRC 1991b).
In addition, the IAEA publishes safety standards in the form of SSRs and guidance in the form of safety standards and guides.1 1 One of these documentsSSR-6, Regulations for the Safe Transport of Radioactive Material (IAEA 2018) is the governing document for transportation and transportation packaging. Although U.S.
transportation and transportation packaging are regulated by 10 CFR Part 71, SSR-6 is still important to review because 10 CFR Part 71 is designed to be compatible with SSR-6 and there are packages that may be certified under SSR-6 standards and used for international shipments to the United States.
PNNL-33999 Transportation Review for HALEU Packages 15 4.0 Transportation Review for HALEU Packages This section discusses aspects of transportation packaging that are specific to enrichments in the HALEU range for UF6, UF4, and UO2 powder feed material. It should be emphasized that this information may change as the state of transportation packages for HALEU feed material is dynamic. Each technical area is evaluated and recommendations regarding further assessments and technical work are made. The general regulations associated with transporting nuclear material do not have HALEU-specific aspects; these include the DOT, U.S. Coast Guard, and state regulations. For this reason, focus is on the NRC regulations and guidance. NUREG-2216 (NRC 2020c) incorporates interim staff guidance and guidance from other sources. It also references several NRC information notices (IN-92-58, IN-97-24, IN-97-20, and IN-16-06) (NRC 2016) and Bulletin 94-02 (NRC 1992, 1994, 1997a, 1997b).
These documents provide additional details on safety issues relevant to the transport of UF6 packages. This section is organized by technical discipline, starting with a general design overview.
4.1 General Package Design Considerations Uranium hexafluoride packages typically consist of an inner steel cylinder that acts as a containment vessel and an outer protective overpack. The protective overpack typically is required for the shipment of enriched UF6 packages. As discussed in NUREG--2216, Appendix A.6, the inner cylinder is carbon steel with rounded ends and a protective skirt. A valve for filling and emptying the cylinder is installed on one end of the cylinder, and a removable plug is installed on the other end. The most commonly used commercial cylinders are approximately 0.76 m (30 in.) in diameter and 2.1 m (81 in.) in length with a capacity of about 2,300 kilograms (2.5 tons) of UF6 (NRC 2020c).
As discussed in NUREG-2216, Appendix A.6, the protective overpack is generally a double-shell, stainless-steel cylinder with cushioning pads on the inner cavity. An energy-absorbing, insulating foam fills the space between the inner and outer shells. The overpack can be separated into two halves to enable easy access to the inner cylinder. Overpacks for the 30 in.
(76 cm) cylinders mentioned above are approximately 0.1016 m (4 in.) thick (NRC 2020c).
United States Enrichment Corporation (now Centrus Energy)-651 (USEC 2017) contains information regarding overpacks.
The design and authorized contents of UF6 cylinders are defined in ANSI N14.1, Nuclear MaterialsUranium HexafluoridePackagings for Transport (ANSI 2023). In addition, in 49 CFR 173.420(a)(2)(i), the DOT requires that the UF6 packages be designed, fabricated, inspected, tested and marked in accordance with(i) American National Standard N14.1 in effect at the time the packaging was manufactured.1 Typically, enriched UF6 is shipped from enrichment facilities to fuel fabrication facilities in 30B cylinders; the previous (2019) revision of ANSI N14.1 specified a maximum enrichment of 5 wt% for 30B and 30C2 cylinders. ANSI N14.1-2023 modified this restriction to allow higher enrichments with additional criticality evaluation.
1 DOT regulations at 49 CFR 171.7, Reference material, incorporates by reference the ANSI standards available for use to satisfy the requirements that a cylinder must meet the standard in effect at the time the packaging was manufactured.
2 The ANSI N14.1 Standard 30C cylinder is essentially a 30B cylinder equipped with a valve protective cover that bolts over and protects the cylinder valve during transport. The valve protective cover is a special design feature that provides additional assurance against the in-leakage of water to the containment system and is an enclosure that retains any leakage.
PNNL-33999 Transportation Review for HALEU Packages 16 For UF6 packages, the primary safety function of the cylinder is to provide containment and moderation control for criticality purposes. Moderation control is required for all commercially used cylinders for fissile UF6 and must be maintained under NCT and HAC. To assure subcriticality by moderation control, the mass of the contents must be at least 99.5 percent UF6 (NRC 2020c).
As discussed in NUREG-2216, Appendix A.6, the cylinder is defined as the containment boundary for the UF6. Unirradiated uranium enriched to less than 5 wt% is a Type A quantity.
Recycled uranium can be a Type B quantity due to the presence of uranium-232, uranium-234, uranium-236, and various radioactive impurities, especially transuranic radionuclides.
For UF6 packages, shielding requirements are generally not significant because of the low radioactivity and self-shielding of UF6 (NRC 2020c). If the contents are recycled uranium, a shielding evaluation is required to show that the package will meet the dose rate limits in 10 CFR 71.47, External radiation standards for all packages, and 10 CFR 71.51, Additional requirements for Type B packages, during NCT and HAC, respectively (NRC 2020c).
The overpack provides thermal protection to prevent overheating of the UF6, which can cause hydraulic failure of the cylinder. The overpack also provides impact protection for the cylinder and the valve (NRC 2020c).
For UF6 packages, NUREG-2216 (NRC 2020c) lists the following safety features:
The steel cylinder precludes in-leakage of water and provides containment under NCTs and HACs.
The cylinder skirt provides some protection for the valve during handling operations, NCT, and HAC.
The overpack provides structural and thermal protection for the cylinder and its valve under HAC.
Typical areas of review involving overpack drawings are (NRC 2020c):
overpack shell materials of construction dimensions and tolerances vents for pressure relief of foam combustion products foam specifications type density compressive strength fire retardant characteristics limit on free chlorides closure devices torque valve protection device
PNNL-33999 Transportation Review for HALEU Packages 17 4.2 Structural The structural review of the package design supports conclusions made on dose rate, criticality, and release. The regulations at 10 CFR 71.55(g) discuss several criteria that must be met to take exception from water in-leakage for traditional UF6 material with a maximum enrichment of 5 wt% of U-235. From a structural point of view, 10 CFR 71.55(g)(1) is of importance.
Following the tests specified in 10 CFR 71.73 (Hypothetical accident conditions), there is no physical contact between the valve body and any other component of the packaging, other than at its original point of attachment, and the valve remains leak tight.
In the case where a specific packaging is used to transport HALEU feed material, the packaging system used to ship the content must be designed so that the contents, convenience canisters, compartmentalized shoring, and storage are not subjected to excess shock and vibration that could damage internal components and reconfigure/redistribute or even possibly disperse contents. However, the need to not subject cargo to excess shock and vibration is not unique to HALEU material packaging. Potential sources of shock and vibration data include NNSA SG-100 (NNSA 2005), NUREG/CR-2146 (Fields 1981), and NUREG/CR-0128 (Magnuson 1978).
MIL-STD-810H Method 514.8 (DOE 2019) also provides guidance for defining vibration environments to which the material may be exposed throughout a life cycle and for the conduct of laboratory vibration tests.
One of the main concerns for the DN30 package, which carried UF6 material with a maximum 5 wt% enrichment of U-235, was the protection of the valve attached to the standard 30B cylinder (designed per the ANSI N14.1 standard), which is made of carbon steel. This valve could be damaged when undergoing HAC drop test conditions; a finite element model of the package using LS-DYNA software was employed to investigate such a possibility. Time history analyses of this package showed inelastic deformations to the 30B cylinder body but not at the valve itself.
With HALEU feed material being more highly enriched than traditional UF6, it is anticipated that additional design features may need to be considered for transportation packages. For example, the DN30-X package has additional design features to control criticality and allows for higher enriched UF6. Specifically, the DN30-X utilizes the 30B-X cylinder, which adds neutron-absorbing materials in a special frame placed inside a traditional 30B cylinder.
Such a frame must maintain its geometry to suppress criticality under NCT and HAC drop tests, like baskets used in traditional SNF packages. The DN30-X package is like the DN30 package as it incorporates valves connected to the cylinders to support filling of UF6. Inelastic deformations at these regions of the cylinder are not permitted, as leak rates cannot be verified accurately as a result. Both the DN30 and DN30-X packages weigh less than 4,536 kg (10,000 lb) and use the protective structural package overpack, which has a clam-shell closure system, making it easier to handle, secure (tie-down), and transport via truck with respect to traditional SNF packages. UF6 is placed in liquid form, and because of its low triple point, it often is treated as a fragile solid. The form of the UF6, whether liquid or solid, does not pose a particular challenge to the containment boundary of the package from a structural point of view.
Another source of feed material that is not from a UF6 source is UO2 powder that has been downblended from HEU. One package that is currently approved to carry this content is the OPTIMUS-L, as described in Eidelpes et al. (2020). However, the OPTIMUS-L package only is certified to carry small amounts of UO2 (no more than a few kilograms) and does not have
PNNL-33999 Transportation Review for HALEU Packages 18 additional criticality controls like the DN30-X package to handle larger amounts. Eidelpes et al.
(2020) propose a new design to carry larger amounts of UO2 based on the existing OPTIMUS-L design called the HALEU transportation concept. The concept uses smaller, inexpensive custom-made canisters that fit in a basket incorporating borated aluminum for criticality control and relies on foam for impact resilience (Figure 1).
Figure 1. HALEU Transportation Concept (Eidelpes et al. 2020)
As discussed for the DN30-X, the HALEU transportation concept from a structural point of view is more complex than the DN30 since the additional basket structure would have to be analyzed as well.
A package that is certified to transport UF4 and UO2 in small quantities is the Versa-Pac (Orano 2022b). UF4 is a solid at room temperature and will not pose structural challenges beyond those already documented. No specific guidance is provided by NUREG-2216 for UF4, but a basket used to control criticality is anticipated when transporting large quantities.
Based on previous UF6 package designs, NUREG-2216 could be updated to elaborate on the need to protect ports and valves that are common to tanks, like the 30B package filled with UF6, and should elaborate on the physical form of the UF6 that could damage the containment boundary, such as brittle UF6 during drop test conditions. No elaboration on highly enriched oxide powders is needed from a structural point of view.
4.3 Thermal Like the structural discipline, the thermal requirements of 10 CFR Part 71 must be met before a package can be certified by the NRC for transporting nuclear materials. Packaging used to transport HALEU feed material and HALEU must be capable of withstanding normal and accident conditions and maintaining shielding and containment limits. Accordingly, all safety significant components of a package containing HALEU feed material must survive a broad temperature range and significant temperature differential exposure as identified in associated regulations presented in Section 3.0.
Design strategies accounting for contents that generate a relatively large amount of heat are not expected to be necessary, as even hundreds or thousands of kilograms of HALEU to fuel a single reactor core stemming from recovery and polishing processes will generate a limited
PNNL-33999 Transportation Review for HALEU Packages 19 amount of decay heat. As such, the issue of thermal protection remains simpler because insulating material must only work effectively to reduce the heat added to the package during an upset or accident condition instead of having to also consider allowing internally generated heat to escape under regular operating conditions. Thermal management design goals typically conflict with one another in situations in which heat-generating content, thermal design requirements, and external heat loads must be carefully balanced during the packaging design evaluation process. Nevertheless, an effective thermal insulation scheme must be evaluated and determined not to cause the interior portions of the package to overheat under HAC or even possibly NCT conditions, as overheating could then lead to failures of safety significant items.
It is important that the package definition be designed so all containment items withstand the highest expected temperature under HAC after the entire structural impact loading sequence (NRC 2005b). After the HAC structural, thermal loading, and water immersion test sequences of the packaging definition, a maximum leak rate of an A2 per week is permissible under HAC as specified in 10 CFR 71.51(a)(2).
Both the DN30 and DN30-X packages used standard 30B cylinders or a slightly modified one such as the 30B-X for the transport of UF6. A thermally susceptible design feature of these cylinders is the solder used to attach the valves to the cylinders, which are filled with UF6. The solder tends to be quite sensitive to relatively low temperatures, (356°F [180°C]), which if exceeded could cause inadvertent release. Another potential thermal challenge is due to the heat capacity of the UF6 and the high pressure that can result from a phase change at high temperatures.
4.4 Containment The containment review verifies that the cylinder meets the containment criteria in 10 CFR Part 71 for Type B packages. Several packages have already been successfully approved to carry UF6, UF4, and UO2. Relatively larger quantities of UF6 have been approved, which have depended on a 30B cylinder meeting ANSI N14.1 requirements, in comparison to UF4 and UO2.
The containment system for UF6 HALEU feed material has been typically based on the 30B cylinders that comply with ANSI N14.1-2019 requirements, which permitted enrichment of only 5 wt%. Future package designs may incorporate larger cylinders as current transportation packages are relatively small, but the containment boundary will still have to resist puncture, water ingress, and thermal loads and, if a Type B package, meet leakage criteria specified for NCT and HAC conditions. Thermal loads can cause increased pressure within the cylinders and may challenge any solder used on the vent and ports located on a tank. Considering the admissible temperature for materials is often quite low (less than 140°C [284°F]), pressure buildup due to melted UF6 after a HAC fire should be noted and accounted for when performing the 10 CFR 71.73(c)(5) immersion test to ensure structural integrity of the containment boundary.
Powder-form UO2 is not expected to cause additional issues with containment as previous packages with powder-form UO2 have been approved.
Shipping HALEU feed material requires that the package design/definition meet appropriate 49 CFR Part 173, Subpart I, and 10 CFR Part 71 requirements, as well as the recommendations of NRC RG 7.11 (NRC 1991a). Generally, 49 CFR 173.417 permits transportation of fissile material in Type AF, B(U)F, and Type B(M)F packages, and if the fissile material package meets the applicable standards in 10 CFR Part 71, a package application must be prepared and submitted to a regulatory body for any of these package types. By definition, a Type B package
PNNL-33999 Transportation Review for HALEU Packages 20 is required if the radionuclide inventory exceeds one A2 quantity (49 CFR 173.431). Evaluations performed for transport of fresh (unirradiated) HALEU composed of recycled and downblended and polished material determined that approximately only 7.7 lb (3.5 kg) or more of HALEU is required to exceed one A2 (Eidelpes et al. 2020). Any one of the proposed commercial advanced reactors will likely require hundreds to thousands of kilograms of HALEU to fuel a single reactor core. As such, the quantities of recycled uranium to be transported can be readily characterized as requiring a Type B(U)F or Type B(M)F packaging definition.
Regulatory Guide 7.11 is the first regulatory guidance to introduce the graded approach based on content categories. The graded approach divides the packages into three categories based on the form and activity level of the contents. The package categories (I, II, and III) indicate the ASME BPVC design requirements imposed on the package to ensure adequate design and development of the component safety groups. These include subcriticality/criticality control, containment, and other items important to safety. In this approach, Category I contents have the highest level of activity and require the highest standards and margins of safety.
According to RG 7.11, only 30 A2 or greater is required to elevate the associated packaging requirements from Category III to Category II. This activity limit is reached by approximately 100 kg of unirradiated HALEU feed material as UF6 (Eidelpes et al. 2020). Thus, an NRC certified transportation package is limited to transporting up to 100 kg of unirradiated HALEU feed material as UF6. Otherwise, content capacity would be well below that needed to support commercial-scale fuel production. However, very little difference exists between Category I and Category II packaging design criteria per the applicable sections of the ASME BPVC per NUREG/CR-3854. To provide flexibility in case the purity of the HALEU feed material is less ideal than anticipated, a Type B, Category I packaging design criteria may need to be considered. The sections that follow explain the design and evaluation implications associated with content category in greater detail.
4.5 Shielding Feed material is non-irradiated and typically does not need to be shipped in a Type B package and does not require a rigorous shielding evaluation. However, if the feed material is from reprocessed or downblended fuel, product impurities and actinides such as U-232 may cause the package to exceed the Type A package limits, and a Type B package may be needed (Eidelpes et al. 2020). Although a shielding evaluation will need to be performed, it is thought that this material would meet regulatory dose rate limits in 10 CFR 71.47 and 10 CFR 71.51(a)(2).
The U-232 isotope has a 68.9-year half-life and decays through a series of much shorter-lived daughter products to the stable nuclide Pb-208. This decay chain goes through Tl-208, which gives off a particularly strong gamma at 2.6 MeV. Because of this strong gamma radiation at the end of the decay chain, the hazard from U-232 daughter products is dependent on the amount of time that has passed since reprocessing (IAEA 2007).
Chapter 5 of NUREG-2216 discusses reviewing shielding analyses for transportation packages.
It states that daughter radionuclides should be addressed and that the source term should be at an appropriate decay time that maximizes radiation levels from parent and daughter radionuclides. Maximizing source from U-232/Tl-208 may not be practical.
Figure 2 shows the activity in gamma radiation per second as a function of gamma energy for several decay times for 1 Ci of U-232 from the ORIGEN code. The gamma spectrum is
PNNL-33999 Transportation Review for HALEU Packages 21 dominated by that of Tl-208. The decay time in this figure that gives the maximum source term for U-232 impurities is 10 years. Further assessment of the presence of impurities, particularly U-232, in a HALEU UF6 package may need to be conducted with a view to determining the need to update NUREG-2216. One practical application of this would be CoC limitations on decay times after reprocessing. A significant presence of daughter products, such as Tl-208, that are not considered within the shielding evaluation could also be disallowed for shipment.
Figure 2. Gamma Activity from the Decay of U-232 from ORIGEN 4.6 Criticality All performance standards and regulatory requirements for U.S. certification of fissile material packages are prepared by the NRC and provided in 10 CFR Part 71. The NRC and the DOT work together to make sure DOT regulations for transporting hazardous material (49 CFR Part 173 and 10 CFR Part 71) are consistent.
For packages that transport fissile material, adequate protection is provided by using a design and safety assessment philosophy that effectively eliminates the possibility of a criticality event occurring under all credible scenarios. This would be no different for applications pertaining to HALEU feed material transport. A detailed consideration of the many parameters that interact to influence the neutron behavior will be needed to provide an adequate safety basis for the package design definition. Principal parameters that affect criticality safety are (1) type, mass, and form of the fissile material; (2) moderator-to-fissile material ratio (degree of moderation);
(3) amount and distribution of absorber materials; (4) package geometry (internal and external);
and 5) reflector effectiveness.
NUREG-2216 was reviewed to evaluate potential gaps for enrichments between 5 and 19.75 wt%. Previous work (Center for Nuclear Waste Regulatory Analyses 2020) has noted a potential lack of criticality benchmark experiments within the 5 to 19.75 wt% range. Saylor et al.
(2021) and Zipperer et al. (2020) discuss benchmarks as well as the use of sensitivity and
PNNL-33999 Transportation Review for HALEU Packages 22 uncertainty analysis methods to identify appropriate benchmarks. The NUREG-2216 process remains the same; however, it is recommended that this reduction in the number of available benchmarks be mentioned within NUREG-2216, Benchmark Evaluations, Section 6.4.6. Having fewer benchmarks does not change the process of evaluation but may require additional scrutiny or justification of bias and bias uncertainties. Additional margin in the analyses or the bias uncertainty may be taken to account for the lack of available benchmark data. The reviewer will have to apply expert judgment to collectively evaluate the additional margin if taken, the number of applicable benchmarks, and other conservatisms within the model.
For reinforcement of enrichment concerns, the authors recommend adding enrichment to the list of experimental data in Section 6.4.6.1 of NUREG-2216 at the end of the sentence verify that the application addresses the overall quality of the benchmark experiments and the uncertainties in experimental data.
Another impact of enrichment greater than 5 wt% is the exemption from water intrusion. 10 CFR 71.55(g)(4) does not allow exemption from water intrusion or leakage into or out of the containment system because enrichment is over 5 wt%; therefore, all criteria in 10 CFR 71.55(b) needs to be demonstrated.
Also note that in the enrichment range from 6 to 34 wt%, heterogeneous systems or models will yield the smallest critical volume, whereas homogeneous systems will yield the smallest critical mass. This differs for enrichments less than 6 wt% as both the critical volume and critical mass are smallest for heterogeneous systems (Zipperer et al. 2020).
4.7 Materials The materials evaluation will need to consider mechanical and thermal properties of the package materials. Special attention should be paid to chemical interactions of feed material under the influence of air, water, or both. The DN-30X and the proposed HALEU UO2 powder concept using the OPTIMUS-L (Eidelpes et al. 2020) packages rely on neutron-absorbing materials for criticality control to be able to transport more highly enriched feed materials.
NUREG-2216 states that up to 90 percent of the boron in the absorber can be credited within the criticality evaluation if neutron attenuation or other appropriate tests have demonstrated the absorber material is homogeneous. Additional information is available to NRC reviewers in A to NUREG-2216.
4.8 Operating Procedures An NRC-approved transportation package is expected to be operated in the manner consistent with its design and evaluation for approval. Operating procedures focus on package loading (including leak testing), unloading (including inspections and tests), empty package for transport considerations (such as decontamination), and other procedures. Regulations specific to these considerations include 10 CFR 71.31(c), 71.35(c), 71.43(g), 71.47(b)(c)(d), 71.87, and 71.89.
Additionally, 49 CFR 173.428 may apply. Reviewing the operating procedures makes sure the valve is properly closed and leak-tested, as appropriate, and the valve protection device, if applicable, is installed. This review also confirms that the radiation levels are verified to meet the regulatory limits prior to transport.
Operations are expected to be very similar to those already existing for packages that are already approved for UF6, such as the DN30. However, these packages weigh less than 10,000 lb and can be lifted with a forklift. If larger amounts of HALEU feed material are to be
PNNL-33999 Transportation Review for HALEU Packages 23 shipped, the package will undoubtedly get heavier; therefore, different equipment that can lift and maintain the package may be needed. A heavier package may need trunnions, in which case lifting operations will need to be considered and may need to be rigged differently when tied down to the conveyance. Additionally, the number of packages that can be grouped together in a shipment may also change with increasing the quantity of feed material (criticality safety index [CSI] will need to be verified). However, these additional needs are not expected to be any different from those used for traditional SNF transportation packages, and therefore, no major revisions to NUREG-2216 Chapter 8 have been identified.
4.9 Acceptance Tests and Maintenance Program A certified transportation package has a maintenance program documented in the CoC to assure packaging performance requirements are being met while in service. This may include visual inspections, weld examinations, thermal tests, shielding tests, leak tests according to ANSI N14.5, neutron-absorber and moderators tests, and lifting tests, among others (ANSI 2014). Before first use, each package is subjected to tests that correspond to its design, and periodic maintenance requirements are detailed for replacement of components and repair. The pertinent regulations are 10 CFR 71.31(c), 71.37(b), 71.85(a)(b)(c), 71.87(b)(g), and 71.93(b).
The review of the acceptance tests and the maintenance program evaluates the inspection procedures for the overpack, including the physical condition of the inner and outer shells, corrosion, performance of the foam while the overpack is in service, and wear of cushioning pads between the cylinder and overpack. The review also verifies that the cylinder is tested and maintained in accordance with the requirements in ANSI N14.1. For foam-filled overpacks, the acceptance tests for the foam should include reasonable ranges for material density, compressive strength, thermal conductivity, and other factors. Structural analyses may be used to justify the ranges. Reference to American Society for Testing and Materials International standards should be reviewed to make sure the standard does not overly restrict the testing of foam characteristics.
Based on previous packages that have been approved to transport feed material, new additional acceptance test and maintenance requirements are not expected to be necessary. Experience from fresh fuel and SNF transportation packages are expected to be knowledge bases when larger shipments of feed material are shipped, and therefore, NUREG-2216 most likely will not need any major revisions in Chapter 9.
4.10 Quality Assurance QA requirements for HALEU feed material packages will not vary from other feed material packages. Although the contents may change, there is no substantial change in requirements based off this difference.
4.11 Appendix A to NUREG-2216 Appendix A to NUREG-2216 has descriptions, safety features, and areas of review for different types of radioactive material transportation packages.
Section A.6 of NUREG-2216 is for LEU hexafluoride packages. This section could be updated to address both low (5 wt%) and higher (5 wt%) enriched uranium. Recommended updates from Sections 4.2 through 4.10 of this report could be added to Section A.6 of NUREG-2216 to address the differences in evaluations in a 5 wt% enriched UF6 package.
PNNL-33999 HALEU Feed Transportation 24 5.0 HALEU Feed Transportation 5.1 Considerations for HALEU Feed Transportation Although HALEU encompasses U-235 enrichment up to 20 wt%, typical feed material would likely be UF6 enriched to approximately 8 wt%, in LWRs, especially in early applications. For non-LWRs, they venture up to 20 wt% enrichment. This material would be produced at a uranium enrichment facility and shipped to either a deconversion facility or a fuel fabrication facility. The deconversion facility would convert the UF6 to uranium metal, uranium oxides, or uranium salts; in the United States, deconversion facilities typically are collocated with fuel fabrication facilities.
One consideration associated with shipping UF6 at HALEU enrichments is the availability of commercially sized cylinders (e.g., similar in size to existing 30B cylinders with capacities of 1,590 to 2,270 kg [3,500 to 5,000 lb]) for LEU. Currently, there are no commercially sized transportation packages certified to handle these enrichment levels at those sizes. This is complicated by the fact that UF6 at any enrichment is a DOT Class 8 hazardous material (i.e., corrosive), and when UF6 contacts moisture in air, it reacts to form hydrogen fluoride and uranyl fluoride, which are extremely corrosive.
Saylor et al. (2021) analyzed the DN-30 UF6 transportation package with uranium enrichments of 5.8, 6.7, and 9.5 wt% and concluded that it would be feasible to ship 30B cylinders with UF6 enriched up to 10 wt% in small arrays. However, DOT regulations (49 CFR 173.420) specify that UF6 must be shipped in ANSI N14.1 certified cylinders and the previous revisions of ANSI N14.1 limit enrichments for 30B and 30C cylinders to 5 wt%. The 2023 edition of ANSI N14.1 (ANSI 2023) retains this as the standard limit; however, it does allow enrichment above these limits subject to additional criticality assessments and approval by the competent authority, in this case NRC.
The requirement to maintain subcriticality under water intrusion may need to be assessed for shipping UF6 at HALEU enrichments. Transportation of uranium enriched to less than 5 wt% in the form of UF6 is addressed in 10 CFR 71.55(g), which excepts a fissile material transportation package from the requirement of maintaining subcriticality under water intrusion if the content is UF6 enriched to less than 5 wt%. Typical HALEU feed material enrichments are in the range of 8 wt%, which exceeds the 5 wt% limit. Unless the Commission approves an exception as described in 10 CFR 71.55(c), subcriticality under water intrusion needs to be maintained.
Another consideration associated with shipping HALEU feed material is the transport of uranium metal, uranium oxides, or uranium salts from a deconversion facility to a fuel fabrication facility.
The primary technical challenge associated with this activity is expected to be the criticality safety assessment associated with the transportation package used for the HALEU feed material. The need for these transportation packages could be eliminated by collocating deconversion and fuel fabrication facilities, as is currently done at LWR fuel fabrication facilities.
However, collocating these facilities would be highly dependent on the specific type of fuel that is produced, and it may not always be possible.
The use of recycled uranium as HALEU feed material also may need to be considered.
Typically, uranium feed material of any enrichment may be shipped in a Type A fissile material transportation package. However, uranium feed material derived from recycled uranium may require a Type B fissile material transportation package due the presence of U-232, U-234,
PNNL-33999 HALEU Feed Transportation 25 U-236, and various radioactive impurities, especially transuranic radionuclides. This issue is discussed in Eidelpes et al. (2020). Eidelpes et al. (2020) found that for HALEU feed material derived from recycled uranium from the EBR-II reactor, a Type B fissile material transportation package would be required if more than 3.4 kg of HALEU were to be shipped.
The following subsections discuss key design areas of a transportation package such as structural, thermal, shielding, criticality, containment, and operations, using NUREG-2216 as a guide, and examine the currently certified transportation packages that carry similar contents to HALEU feed material, such as the DN30, Optimus-L, the Versa-Pac, and the DN30-X.
Revalidation packages such as the MST-30 package are also examined.
5.2 Future Transportation Packaging Needs To meet the need for industrial-scale HALEU production, new packages that can transport UF6, and other uranium forms at scale may be needed. Some of this work designing new packages and certifying contents in existing packages is underway and certifications are being issued contemporaneously with this report. The following section identifies these packaging needs based off different process flows.
Figure 3 shows the uranium feed material flow as it currently occurs. Uranium hexafluoride is transported from conversion facilities to enrichment facilities to fuel fabrication facilities. At the fuel fabrication facilities, deconversion of the UF6 occurs, and uranium oxide LWR fuel is fabricated. No new transportation packages are necessary in this scenario. Also note there is no need for a package to ship uranium powder or metal since the deconversion and fuel fabrication facilities are collocated.
Figure 3. Current Uranium Feed Material Flow Figure 4 and Figure 5 illustrate scenarios where large-scale production of HALEU feed material occurs at enrichment facilities and the HALEU is subsequently transported to deconversion and fuel fabrication facilities. If the deconversion and fuel fabrication facilities are consolidated (see Figure 4), two new transportation packages would be required for large-scale, commercial transport of UF6 and fresh fuel, which could be in the form of uranium nitride, uranium silicide, uranium metal alloys, or uranium salts. Optionally, these packages could be revisions of existing packages for new contents. If the deconversion and fuel fabrication facilities are separate (see Figure 5), three new transportation packages would be required for large-scale, commercial transport of UF6, UO2 powder, and fresh fuel. The additional packages are required for the large-scale, commercial transport of uranium enriched to greater than 5 wt%.
PNNL-33999 HALEU Feed Transportation 26 Figure 4. HALEU Production at Enrichment Facilities Figure 5. Variation on HALEU Production at Enrichment Facilities Figure 6 through Figure 11 illustrate scenarios where LEU enriched to greater than 5 wt%
(LEU+) or HEU is used to provide a stopgap source of uranium for downblending until large-scale, commercial enrichment capacity for HALEU is developed. This stopgap scenario could potentially provide approximately a few tens of metric tons of HALEU feed material to demonstrate initial advanced reactor concepts.
Figure 6 illustrates a scenario where stopgap LEU+ or HEU is transported and used to increase the enrichment of uranium from commercial uranium enrichment facilities that is enriched to less than 5 wt%. In this scenario, up to three new transportation packages would be required, one package to transport the LEU+ or HEU; another package to ship uranium metal, uranium oxide, or uranium salts from deconversion facilities to fuel fabrication facilities; and a third package to ship fresh fuel in the form of uranium nitride, uranium silicide, uranium metal alloys, or uranium salts.
PNNL-33999 HALEU Feed Transportation 27 Figure 7 illustrates a variation on Figure 6, where the deconversion and fuel fabrication facilities are collocated. This decreases the need for new transportation packages from three to two.
Figure 8 illustrates a second variation on Figure 6, where the source facility for the LEU+ or LEU, deconversion facilities, and fuel fabrication facilities are collocated. This decreases the need for new transportation packages from three to one.
Figure 9 illustrates a third variation on Figure 6, where the source facility for the LEU+ or LEU, the blending facilities, deconversion facilities, and fuel fabrication facilities are separately located. This increases the need for new transportation packages from three to four.
Figures 10 and 11 illustrate a fourth and fifth variation on Figure 6, where the source facility for the LEU+ or LEU and the blending facilities are combined, and the deconversion facilities and fuel fabrication facilities are either combined or separate. In these scenarios, either two or three new packages would be required.
As demonstrated by these figures, the need for new packaging may be reduced by collocating facilities as part of the development of a fuel production cycle to support commercial-scale nuclear power production from advanced reactors. Additionally, some packages could be designed or adapted from existing designs to accommodate higher percentages of enrichment, such as to support downblending from HEU, that could then be used for similar fuel form feed material with lower levels of enrichment (HALEU). Section 5.3 discusses existing packages that could be adapted or utilized.
Figure 6. Stopgap Scenario for Production of HALEU
PNNL-33999 HALEU Feed Transportation 28 Figure 7.
Variation on the Stopgap Scenario for Production of HALEU Figure 8.
Second Variation on the Stopgap Scenario for Production of HALEU
PNNL-33999 HALEU Feed Transportation 29 Figure 9.
Third Variation on the Stopgap Scenario for Production of HALEU Figure 10. Fourth Variation on Stopgap Scenario for Production of HALEU
PNNL-33999 HALEU Feed Transportation 30 Figure 11. Fifth Variation on Stopgap Scenario for Production of HALEU 5.3 NRC-Approved Transportation Packages 5.3.1 Packages with Current CoCs 5.3.1.1 UF6 Packages The three UF6 packages that have been issued a CoC by the NRC are 1) the UX-30 (Docket No. 71-9197) (NRC 2018), 2) the DN-30 (Docket No. 71-9362) (NRC 2023a), and 3) the DN30-X (Docket No. 71-9388) (NRC 2023b).
The UX-30 is a Type B package authorized to transport UF6 containing small amounts of impurities from reprocessed fuel that exceed the A2 limit for a Type A package. The UX-30 package can be used to transport unirradiated uranium with a U-235 enrichment up to 5 wt% in an ANSI N14.1 Standard 30B or 30C cylinder. It also can be used to transport reprocessed uranium with a U-235 enrichment not to exceed 5 wt%. The most recent CoC is Revision 31, issued September 2023.
The DN-30 is a Type AF package and is authorized to transport fresh UF6 with a U-235 enrichment not to exceed 5 wt% in the standard 30B cylinder. The most recent CoC is Revision 4, dated March 2023.
ANSI N14.1 states that the maximum fill limit of the 30B and 30C cylinders is 2,277 kg (5,020 lb)
UF6. Table 4 of the standard states that enrichments above 1 wt% require moderation control.
The criticality safety analyses for the UX-30 (Columbiana Hi Tech 2018) and DN-30 (DAHER 2019) do not include moderators or water ingress into the containment system. It was determined that the 30B and 30C cylinders contain special design features that would make sure water could not leak into the containment system so that they qualified for moderator
PNNL-33999 HALEU Feed Transportation 31 exclusion as allowed by 10 CFR 71.55(c). The packages also met the additional requirements in 10 CFR 71.55(g) for UF6 packages that employ moderator exclusion, including a limit of uranium enrichment of 5 wt% U-235.
The CSI controls the number of packages that can be shipped in a single conveyance. Per the requirements in 10 CFR 71.59(c) for a nonexclusive use conveyance, the sum of all CSIs is limited to 50, while for an exclusive use conveyance, the sum of all CSIs is limited to 100.
Table 2 summarizes the CSIs and the number of packages that can be transported in a single conveyance for the UX-30 and DN-30.
Table 2. CSI and Number of Packages that are Allowed in a Single Conveyance for the UX-30 and DN-30 Packages Package Cylinder CSI Number of Packages Allowed in Single Conveyance Nonexclusive Exclusive UX-30 30B 5.0 10 20 30C 0.0 No Limit No Limit DN-30 30B 0.0 No Limit No Limit The Orano-TLI Versa-Pac is authorized for shipping UF6 in 1S or 2S cylinders at enrichments up to 20 wt%, but in small quantities. The 1S and 2S cylinders are designed to be ANSI N14.1 compliant. The most recent CoC for the Versa-Pac is Revision 18, Docket No. 71-9342 (NRC 2023a). Table 3 and Table 4 below repeat the CoC tables describing the allowable contents for the 1S and 2S cylinders.
Table 3. Versa-Pac VP-55 1S and 2S Cylinder Limits for UF6 Enrichment up to 20 Wt% U-235 Cylinder Type Mass UF6 per VP-55 (g)
Number of Cylinders U-235 Mass Limit per VP-55 (g)
CSI 1S 3,175 7
429.8 1.0 2S 4,445 2
600.8 1.0 Table 4. Versa-Pac VP-55 1S and 2S Cylinder Limits for UF6 with 5-inch Pipe, U-235 Enrichment up to 100 Wt%
Cylinder Type Mass UF6 per VP-55 (g)
Number of Cylinders U-235 Mass Limit per VP-55 CSI 1S 454 1
306 1.0 2S 2,223 1
1497 1.0 Transport of LEU as UF6 in 30B and 30C cylinders in UX-30 and DN-30 packages arguably sets the precedent for commercial operations. These packages allow up to 2,277 kg of UF6 to be transported but are not currently authorized for shipping uranium with an enrichment higher than 5 wt%. In contrast, Versa-Pac VP-55 packages are authorized for transporting uranium with an enrichment up to 100 wt%, but the mass can be no more than approximately 0.2 percent of that allowed for LEU. The authors consider that a package supporting commercial operations should have a capacity within an order of magnitude of the commercial precedent set by LEU transport.
PNNL-33999 HALEU Feed Transportation 32 The DN30-X (NRC Docket No. 71-9388) was approved by the NRC in March 2023 for transportation of UF6 with enrichments up to 20 wt%. The SARP (Orano 2022a) states that there are two variants of the package: the DN30-10 and the DN30-20. Table 5 summarizes the authorized contents.
Table 5. Summary of Proposed DN-30X Contents Package Variant Cylinder Enrichment Limit Mass of UF6 in kg CSI DN30-10 30B-10 10 1460 0
DN30-20 30B-20 20 1271 0
The 30B-10 and 30B-20 cylinders are variants of the standard 30B cylinder but include an interior criticality control system, which consists of control rods containing a neutron poison in the form of boron carbide and lattice holders that keep each control rod in place. Because the enrichment exceeds 5 wt%, the DN30-X cannot apply moderator exclusion; therefore, criticality analyses assume that there is water in-leakage to the most reactive extent. Authorization of these packages provides for commercial operations given the UF6 mass limit is within an order of magnitude of the commercial precedence (2,277 kg LEU UF6). However, the payload is still reduced compared to a 5 wt% enrichment content.
5.3.1.2 Packages that Could Potentially Ship Higher Enriched UO2 Powders and Compacts Versa-Pac As well as UF6, the Versa-Pac can be used to ship HEU powder and uranium compounds such as UF4. This content is allowed in both the VP-55 and VP-110 packages. Limits are based on the enrichment limit, how much hydrogenous packing material is present, whether the material will be inside the 5-in. pipe, and whether the package will be transported by air or by ground/vessel transport. In addition, there are different CSIs for different allowable loadings. As discussed in Eidelpes et al. (2020), highly enriched UO2 powder from EBR-II fuel could be used to make HALEU feed material. Because the Versa-Pac is a Type AF package and does not allow for actinides and impurities in the amount exceeding one A2 (see Section 3.0), this package may not be able to transport large quantities of this material. Table 6 shows the U-235 mass limits for various conditions. These limits apply to packages with no limit on hydrogenous packing materials. Table 7 has higher U-235 mass limits for when hydrogenous packing materials are limited to 454 g (1 lb).
PNNL-33999 HALEU Feed Transportation 33 Table 6. Versa-Pac VP-55 and VP-100 Loading Limits for Uranium Materials (excluding UF6)
Weight Percent U-235 U-235 Mass Limit (g) for VP-55 and VP-110 CSI U-235 Mass Limit for VP-55 with 5-inch pipe (g)
CSI Ground/Vessel Air Ground/Vessel Air 100%
360 360 1.0 695 395 1.0 20%
445 445 1.0 1,215 495 1.0 10%
505 505 1.0 Limited by volume of pipe, 122 kg (269 lb) uranium metal, 60 kg (132 lb) UO2, 45 kg (99 lb) U3O8 590 0.7 5%
610 610 1.0 Limited by volume of pipe, 122 kg (269 lb) uranium metal, 60 kg (132 lb) UO2, 45 kg (99 lb) U3O8 790 0.7 1.25%
1,650 Limited by volume of pipe, 122 kg (269 lb) uranium metal, 60 kg (132 lb) UO2, 45 kg (99 lb) U3O8 790 0.7 Table 7. Versa-Pac VP-55 Loading Limits for Uranium Materials with Limited Hydrogenous Packing Material (excluding UF6)
Weight Percent U-235 U-235 Mass Limit (g) for VP-55 Material in 5-in. Pipe Container for VP-55(a)
CSI=0.7 CSI=1.0 No. pipes CSI 100%
515 1
395 20%
605 635 2 in. high-capacity basket (uranium metal not allowed)
CSI = 0.7 for U3O8, UO3, and UF4 CSI = 1.4 for all other compounds 10%
685 2
CSI = 0 for uranium oxides CSI = 1.4 for all other compounds and uranium metal 5%
800 2
CSI = 0 for uranium oxides CSI = 1.4 for all other compounds and uranium metal (a) Note that when transporting within the 5-inch pipe container, the mass is limited by the volume of the pipes, which corresponds to mass limits of 122 kg (269 lb) uranium metal, 60 kg (132 lb) UO2, and 45 kg (99 lb) U3O8 per pipe.
To conclude from the tables, neither the VP-55 nor VP-100 has the capacity to ship commercial-scale quantities of HALEU feed material, assuming the LEU UF6 mass limit of 2,277 kg (2.5 tons) sets the commercial precedent. The transportable mass of these packages is limited to approximately 7 kg (15,4 lb) of total uranium at 10 wt% enrichment. Even accounting for UO2 being 76 percent of the mass of UF6 for the same uranium mass, these packages are several orders of magnitude too small to support commercial operations.
PNNL-33999 HALEU Feed Transportation 34 OPTIMUS-L A concept has been developed for transporting larger amounts of higher enriched UO2 powder downblended from HEU (Eidelpes et al. 2020) that uses the Nuclear Assurance Company Optimal Modular Universal Shipping for Low-Activity Contents OPTIMUS-L (NRC Docket No.
71-9390) (NRC 2022a). Eidelpes et al. (2020) suggest the package capacity could be up to 376 kg (829 lb) of HALEU. This capacity is equivalent to approximately 500 kg (1102.3 lb) of UF6 and likely could support commercial operations given the commercial precedence of 2,277 kg (2.5 tons) UF6 as LEU described earlier.
For the OPTIMUS-L, the latest CoC is Revision 3, issued in February 2024. It expires on December 31, 2026. This package is currently authorized for transuranic waste and LEU less than 1 wt% enrichment. Although the U-235 limits are far below that evaluated in the concept in Eidelpes et al. (2020), the other package evaluation areas for the currently approved design that are independent of the basket design and contents are likely applicable for the basket design and content in Eidelpes et al. (2020). It is unlikely that a new thermal evaluation would need to be performed, and the mass of the contents in Eidelpes et al. (2020) is bounded by the allowable mass in the current CoC; therefore, the structural analysis of the overpack should be applicable. Although a shielding evaluation may need to be performed for the new contents, it is unlikely that the fresh fuel contents would result in a higher dose rate than the currently approved contents.
CHT-OP-TU The TN CHT-OP-TU is authorized to ship uranium oxide pellets, powder, and uranium-bearing materials limited to a U-235 enrichment up to 5 wt%. The most recent CoC for the CHT-OP-TU is Revision 12, Docket No. 71-9288, issued on July 13, 2020 (NRC 2020a). The CHT-OP-TU is a cube-shaped package. The UO2 is contained in four steel oxide vessels in three available sizes: 8 in. (20.3 cm), 7.5 in. (19 cm), and 6 in. (15.2 cm) nominal inside diameter. The mass of all contents is restricted to 729 kg (1,608 lb) per package and 182 kg (402 lb) per each oxide vessel. Hall et al. (2020) analyzed this package (and other existing transportation packages) for use with HALEU fuel. Results of this study show that the CHP-OP-TU could be adapted to transport increased enrichment UO2 powder by reducing the size of the HAC array (i.e.,
increasing the CSI) and/or reducing the oxide vessel diameter. Enrichment up to 18 wt% U-235 was studied.
ES-3100 The ES-3100 is authorized to ship [u]ranium as oxide, which may include UO2, UO3, and U3O8, packaged in stainless-steel, tin-plated carbon steel, or nickel-alloy convenience cans, or polyethylene bottles. The physical form of all contents is dense, loose powder which may contain clumps and pellets. The ES-3100 is also authorized to ship uranium in other forms.
The most recent CoC for the ES-3100 is Revision 16, Docket No. 71-9315 and was issued on January 5, 2021 (NRC 2021a). For UO2 powder, the ES-3100 is not limited by enrichment but is limited by mass of U-235, either 9.682 kg (21.3 lb) U-235 and 921 g (2,030.5 lb) carbon with a CSI of 0.0 or a U-235 mass of 12.32 kg (27 lb), and no carbon with a CSI of 0.4. Although this package is a Type B package and could be used to ship higher enriched UO2 powder, it is limited in size, as the overall dimensions are 110 cm (43 in.) in height and 49 cm (19 in.) in diameter and its capacity is approximately 100 times smaller than that set by commercial precedence (2,277 kg [2.5 tons] of LEU UF6).
PNNL-33999 HALEU Feed Transportation 35 5.3.2 Revalidations The DOT has issued a certificate for import and export shipments using the Japanese certificate J/159/AF-96 Rev. 3 for the MST-30 package (U.S. DOT 2021). The DOT certificate number for this package is USA/0585/AF-96 Rev. 5 and the NRC docket number is 71-3057. This certificate states that there is up to 2,277 kg [2.5 tons] UF6 allowed with a CSI of zero and an enrichment of 5 wt% or less. The NRC SER (NRC 2021b) recommending revalidation of this certificate states that it uses the 30B cylinder. The DOT certificate was issued on February 10, 2021, and expires on March 4, 2025.
PNNL-33999 Conclusions and Recommendations 36 6.0 Conclusions and Recommendations This report discussed the framework and review process for feed material packaging and transportation. The NRC regulations and guidance were evaluated in detail in Section 4.0. In Section 5.0, the transportation needs were evaluated along with current packaging available or under review.
Some key conclusions, and recommendations for the NRC from this research and evaluation:
Regarding UF6 cylinder designs for material enriched above 5 wt%, further assessment of accounting for moderator intrusion in fissile material packages may be needed. This 5 wt%
threshold could introduce potential challenges to existing facilities and operations. Most impactful will likely be criticality control through spacing and material loading limits. A more rigorous design and review for the structural, containment, and criticality evaluations may be needed for new applications.
The performance-based requirements of 10 CFR Part 71 and related NUREG-2216 guidance are inherently adaptable and do not require any substantial changes because of this adaptability. Minor updates to NUREG-2216 for specific design features of HALEU feed material packages to account for the necessary criticality evaluations could be considered. Although an update of NUREG-2216 is not strictly necessary, work now could streamline the review process in the future.
There are several packages both approved and under review that can be used to transport HALEU feed material. The DN30-X has been approved and has capacity for commercial operations. There are active concepts under review for HALEU powder transportation. A concept based on the Nuclear Assurance Company Optimus-L is of sufficient capacity to support commercial operations. However, transport of powder would only be required if deconversion and fuel fabrication facilities are not collocated (such facilities are collocated for commercial LEU operations). HALEU feed material encompasses a wide range of enrichments, from 5 to 20 wt%, and the review of transportation regulations and guidance did not identify any cliff edge technical barriers to increasing enrichment all the way through this range. However, not all reactors will require the upper end of the HALEU range, and in general, package design challenges will increase as enrichment limits are increased. For this reason, it may not be economical for vendors to certify a package at enrichments all the way through the range 5-20 wt%. Practically, many shipments will be near 10 wt% enrichment. For this reason, the initial packages are not expected include the full enrichment range and potentially need reviews to be recertified or replaced to accommodate higher enrichment.
More development for criticality benchmarks may be needed to accommodate more efficient and effective reviews of packages with higher enrichments. Although currently there is no safety issue, criticality benchmarks for these higher enrichments will reduce the uncertainty that needs to be incorporated into criticality calculations, thereby effecting a more efficient and timely review and certification process. It is possible that vendors will initially certify at lower enrichments and move up the range later.
There may be areas that future information or additional assessment is needed, including for revalidation reviews to support the DOT and if international shipments in accordance with SSR-6 are contemplated.
PNNL-33999 References 37 7.0 References 10 CFR Part 71. 2022. Code of Federal Regulations, Title 10, Energy, Part 71, Packaging and Transportation of Radioactive Material. https://www.govinfo.gov/app/collection/cfr/2022/.
42 U.S.C. 16281. 2022. Advanced Nuclear Fuel Availability. Office of Nuclear Energy, U.S.
Department of Energy. https://www.federalregister.gov/documents/2022/12/07/2022-26577/notice-of-establishment-high-assay-low-enriched-uranium-haleu-consortium 44 FR 38690. July 1979. MOU between the NRC and the DOT. Federal Register, U.S.
Department of Transportation and U.S. Nuclear Regulatory Commission.
Anderson, B. L., R. W. Carlson, and L. E. Fischer. 1996. Containment Analysis for Type B Packages Used to Transport Various Contents. NUREG/CR-6487; UCRL-ID-124822. U.S.
Nuclear Regulatory Commission, Washington, D.C.
ANSI. 2014. Revision and Leakage Rate Testing Considerations. ANSI N14.5-2014. American National Standards Institute.
ANSI. 2023. Uranium Hexafluoride Packagings Transport. ANSI N14.1-2023. American National Standards Institute.
ASME. 2015. BPVC Section III-Rules for Construction of Nuclear Facility Components-Division 1-Subsection NB-Class 1 Components. American Society of Mechanical Engineers.
ASME. 2019a. BPVC Section III-Rules for Construction of Nuclear Facility Components-Division 1-Subsection NG-Core Support Structures. American Society of Mechanical Engineers.
ASME. 2019b. BPVC Section III-Rules for Construction of Nuclear Facility Components-Division 1 Subsection NF-Supports. American Society of Mechanical Engineers.
ASME. 2019c. BPVC Section VIII-Rules for Construction of Pressure Vessels Division 1.
American Society of Mechanical Engineers.
Baker, A. 2019. HALEU for Fuel Development and Microreactor Demonstration at Idaho National Laboratory. INL/CON-19-54336.
BWXT. 2018. BWXT Subsidiary Awarded Six-Year, $505 Million Contract for Highly Enriched Uranium Downblending Services. BWX Technologies, Inc.
Center for Nuclear Waste Regulatory Analyses. 2020. Information Gaps and Potential Information Needs Associated with Transportation of Fresh (Unirradiated) Advanced Reactor Fuel Types. NRC ADAMS Accession No. ML21021A326.
Columbiana Hi Tech. 2018. Safety Analysis Report for Model UX-30 Package. NRC ADAMS Accession No. ML18298A068.
PNNL-33999 References 38 DAHER. 2019. Safety Analysis Report, DN30 Package. 0023-BSH-2016-002-Rev1; NRC ADAMS Accession No. ML19200A133. https://www.nrc.gov/docs/ML1920/ML19200A133.pdf.
DOE. 2021. Request for Information (RFI) Regarding Planning for Establishment of a Program to Support the Availability of High-Assay Low-Enriched Uranium (HALEU for Civilian Domestic Research, Development, Demonstration, and Commercial Use. Department of Energy, Office of Nuclear Energy. https://www.federalregister.gov/documents/2021/12/14/2021-26984/request-for-information-rfi-regarding-planning-for-establishment-of-a-program-to-support-the.
DOE. 2022. DOE Announces Cost-Shared Award for First-Ever Domestic Production of HALEU for Advanced Nuclear Reactors. Department of Energy.
DOE. n.d. Microreactor Applications Research Validation and Evaluation Project (MARVEL).
https://factsheets.inl.gov/FactSheets/20-50248_MARVEL_Fact_Sheet_R15.pdf.
Eidelpes, E., B. M. Hom, R. A. Hall, H. E. Adkins, and J. J. Jarrell. 2020. A High-Assay Low-Enriched Uranium Fuel Transportation Concept. Nuclear Science and Engineering 195 (3):
279-299. https://doi.org/10.1080/00295639.2020.1802161.
ENR. 2022, Barasso Responds to Terra Power Announcement.
https://www.energy.senate.gov/2022/12/barrasso-responds-to-terrapower-announcement.
Fields, S. R. 1981. Dynamic Analysis to Establish Normal Shock and Vibration of Radioactive Material Shipping Packages: Quarterly Progress Report April 1, 1981 - June 30, 1981.
NUREG/CR-2146, Vol. 2; HEDL-TME 83-B. Hanford Engineering Development Laboratory, Richland, WA.
Fischer, L. E., and W. Lai. 1985. Fabrication Criteria for Shipping Containers. NUREG/CR-3854; UCRL-53544. Lawrence Livermore National Laboratory, Livermore, CA.
Freels, J. 2021. Public Meeting Low Enriched Uranium Plus (Leu+) Project. ML21158A290.
https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML21158A290.
Hall, R., W. J. Marshall, and W. A. Wieselquist. 2020. Assessment of Existing Transportation Packages for Use with HALEU. ORNL/TM-2020/1725; TRN: US2214676. Oak Ridge National Laboratory, Oak Ridge, TN.
Huff, K. 2022. Inflation Reduction Act Keeps Momentum Building for Nuclear Power.
Department of Energy, Office of Nuclear Energy. https://www.energy.gov/ne/articles/inflation-reduction-act-keeps-momentum-building-nuclear-power.
IAEA. 2007. Management of Reprocessed Uranium, Current Status and Future Prospects.
IAEA-TECDOC-1529, International Atomic Energy Agency, Vienna.
IAEA. 2012. Regulations for the Safe Transport of Radioactive Material. 2012 Edition, Specific Safety Requirements No. SSR-6. International Atomic Energy Agency.
IAEA. 2018. Regulations for the Safe Transport of Radioactive Material. 2018 Edition, Specific Safety Requirements No. SSR-6 Rev. 1. International Atomic Energy Agency.
PNNL-33999 References 39 Johnson, J., M. W. Patterson, and A. Wagner. 2022. MARVEL Fuel Fabrication Strategy.
INL/RPT-22-66550, Revision 0. Idaho Falls, ID.
https://inldigitallibrary.inl.gov/sites/sti/sti/Sort_59606.pdf.
Magnuson, C. F. 1978. Shock and Vibration Environments for a Large Shipping Container During Truck Transport (Part II). SAND-78-0337; TRN: 78-014761. Sandia National Laboratories, U.S. Nuclear Regulatory Commission. DOI:https://doi.org/10.2172/7030481 Merrifield, J. S., E. Teplinsky, S. L. Fowler, and A. L. Meredith. 2022. Department of Energy Establishes the High-Assay, Low-Enriched Uranium (HALEU) Consortium.
https://www.pillsburylaw.com/en/news-and-insights/doe-haleu-consortium.html.
Mok, G. C., L. E. Fischer, and S. T. Hsu. 1992. Stress Analysis of Closure Bolts for Shipping Casks. NUREG/CR-6007; UCRL-ID-110637. U.S. Nuclear Regulatory Commission.
NNSA. 2005. Safety Guide: Design and Development Guide for NNSA Type B Packages.
NNSA Service Center Safety Guide SG-100, Rev. 2.
NRC. 1978. Design Criteria for the Structural Analysis of Shipping Cask Containment Vessels.
U.S. Nuclear Regulatory Commission Regulatory Guide 7.6, Revision 1. Washington, D.C.
NRC. 1989. Load Combinations for the Structural Analysis of Shipping Casks for Radioactive Material. U.S. Nuclear Regulatory Commission Regulatory Guide 7.8, Revision 1. Washington, D.C.
NRC. 1991a. Fracture Toughness Criteria of Base Material for Ferritic Steel Shipping Cask Containment Vessels with a Maximum Wall Thickness of 4 Inches (0.1 M). U.S. Nuclear Regulatory Commission Regulatory Guide 7.11. Washington, D.C.
NRC. 1991b. Fracture Toughness Criteria of Base Material for Ferritic Steel Shipping Cask Containment Vessels with a Wall Thickness Greater Than 4 Inches (0.1 M) but Not Exceeding 12 Inches (0.3 M). U.S. Nuclear Regulatory Commission Regulatory Guide 7.12. Washington, D.C.
NRC. 1992. Information Notice No. 92-58: Uranium Hexaflouride Cylinders - Deviations in Coupling Welds. U.S. Nuclear Regulatory Commission, Office of Nuclear Material Safety and Safeguards, Washington, D.C.
NRC. 1994. NRC Bulletin 94-02: Corrosion Problems in Certain Stainless Steel Packagings Used to Transport Uranium Hexafluoride. U.S. Nuclear Regulatory Commission.
NRC. 1997a. NRC Information Notice No. 97-20: Identification of Certain Uranium Hexafluoride Cylinders That Do Not Comply with Ansi N14.1 Fabrication Standards. U.S. Nuclear Regulatory Commission.
NRC. 1997b. NRC Information Notice No. 97-24: Failure of Packing Nuts on One-Inch Uranium Hexafluoride Cylinder Valves. U.S. Nuclear Regulatory Commission.
NRC. 2005b. Standard Format and Content of Part 71 Applications for Approval of Packages for Radioactive Material. Regulatory Guide 7.9, Revision 2. Washington, D.C.
PNNL-33999 References 40 NRC. 2012. Administrative Guide for Verifying Compliance with Packaging Requirements for Shipments of Radioactive Materials. Regulatory Guide 7.7, Revision 1. Washington, D.C.
NRC. 2013. Physical Protection of Shipments of Irradiated Reactor Fuel. NUREG-0561, Revision 2. U.S. Nuclear Regulatory Commission.
NRC. 2015. Establishing Quality Assurance Programs for Packaging Used in Transport of Radioactive Material. U.S. Nuclear Regulatory Commission Regulatory Guide 7.10, Revision 3.
Washington, D.C.
NRC. 2016. NRC Information Notice in-16-06: Uranium Hexafluoride Cylinders with Potentially Defective 1-Inch Valves. U.S. Nuclear Regulatory Commission.
NRC. 2018. Certificate of Compliance for Radioactive Material Packages. Certificate No. 9196, Revision No. 30, Docket No. 71-9196, Package Identification No. USA/9196/B(U)F-96, Model No. UX-30, NRC ADAMS Accession No. ML18309A117.
NRC. 2020a. Certificate of Compliance for Radioactive Material Packages. U.S. Nuclear Regulatory Commission Certificate No. 9288, Revision No. 12, Docket No. 71-9288, Package Identification Number USA/9288/B(U)F-96, Model No. CHT-OP-TU, NRC ADAMS Accession No. ML20128J242.
NRC. 2020b. Leakage Tests on Packages for Shipment of Radioactive Materials. Regulatory Guide 7.4, Revision 2. Washington, D.C.
NRC. 2020c. Standard Review Plan for Transportation Packages for Spent Fuel and Radioactive Material. Report No. NUREG-2216. Washington, D.C.
NRC. 2020d. Uranium Enrichment. https://www.nrc.gov/materials/fuel-cycle-fac/ur-enrichment.html.
NRC. 2021a. Certificate of Compliance for Radioactive Material Packages. U.S. Nuclear Regulatory Commission Certificate No. 9315, Revision No. 17, Docket No. 71-9315, Package Identification Number USA/9315/AF-96, Model No. ES-3100, NRC ADAMS Accession No. ML21005A252.
NRC. 2021b. Safety Evaluation Report. Docket No. 71-3057, Model No. MST-30, Japanese Certificate of Competent Authority J/159/AF-96, Revision No. 3, NRC ADAMS Accession No. ML21007A361.
NRC. 2022a. Certificate of Compliance for Radioactive Material Packages. No. 9390, Revision No. 1, Docket No. 71-9390, Package Identification No. USA/9390/B(U)F-96, Model No.
OPTIMUS-L, NRC ADAMS Accession No. ML22020A171.
NRC. 2022b. Proposed Rule. Harmonization of Transportation Safety Requirements with International Atomic Energy Agency Standards. U.S. Nuclear Regulatory Commission, Federal Register Number 2022-18520.
PNNL-33999 References 41 NRC. 2023a. Certificate of Compliance for Radioactive Material Packages. U.S. Nuclear Regulatory Commission Certificate No. 9362, Revision No. 3 Docket No. 71-9342. Package Identification Number USA/9362/AF-96 Model No. DN-30, NRC ADAMS Accession No. ML21236A081.
NRC. 2023b. Certificate of Compliance for Radioactive Material Packages. U.S. Nuclear Regulatory Commission Certificate No. 9388, Revision No. 0, Docket No. 71-9388, Package Identification Number USA/9388/AF-96, Model No. DN30-X, NRC ADAMS Accession No. ML23083B978.
Nuclear Newswire. 2022a. Centrus signs to complete HALEU demo in 2023 as the DOE prepares draft RFP. Nuclear News. https://www.ans.org/news/article-4555/centrus-signs-to-complete-haleu-demo-in-2023-as-the-doe-prepares-draft-rfp/.
Nuclear Newswire. 2022b. DOE Plans Offtake Contracts to Stock a HALEU Bank as Soon as Possible. Nuclear News. https://www.ans.org/news/article-4433/doe-plans-offtake-contracts-to-stock-a-haleu-bank-as-soon-as-possible/.
Orano. 2022a. Safety Analysis Report Dn30-X Package. 0045-BSH-2020-001, Rev. 3, November 23, 2022, Docket No. 71-9388, NRC ADAMS Accession No. ML22327A183.
Orano. 2022b. Versa-Pac Safety Analysis Report. Rev. 13, July 2022, Docket No. 71-9342.
Patterson, M. W. 2021. Update on EBR-II Used Fuel Treatment. Presentation to the National Academy of Sciences Committee: Merits and Viability of Different Nuclear Fuel Cycles and Technology Options and the Waste Aspects of Advanced Nuclear Reactors.
https://www.nationalacademies.org/documents/embed/link/LF2255DA3DD1C41C0A42D3BEF0 989ACAECE3053A6A9B/file/DBD75CCC139AB186D139C328484B4627159D8362D0B2?noSa veAs=1.
PHMSA. 2008. Radioactive Material Regulations Review. U.S. Department of Transportation, Pipeline and Hazardous Materials Safety Administration Washington, D.C.
https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/training/hazmat/56526/ramreview200 8.pdf Regalbuto, M. C. 2020. High-Assay Low Enriched Uranium Demand and Deployment Options:
HALEU Workshop Report. Idaho National Laboratory INL/EXT-21-61768, Revision 3a, Idaho Falls, ID.
SAM.gov. n.d. Industry Day - Notice of Intent/Sources Sought for the Purchase of Enriched Uranium in the Form of High Assay Low Enriched Uranium (HALEU).
https://sam.gov/opp/b32bb0e21e5f4257a35b56a1c4dcc5c6/view.
Saylor, E. M., A. Lang, and R. Hall. 2021. Analysis of the 30b Uf6 Container for Use with Increased Enrichment. ORNL/TM-2021/2043. Oak Ridge National Laboratory, Oak Ridge, TN.
The White House. 2016. Fact Sheet: Transparency in the U.S. Highly Enriched Uranium Inventory. https://obamawhitehouse.archives.gov/the-press-office/2016/03/31/fact-sheet-transparency-us-highly-enriched-uranium-inventory.
PNNL-33999 References 42 U.S. DOT. 2021. Competent Authority Certification for a Type Fissile Radioactive Materials Package Design Certificate. USA/0585/AF-96, Revision 5, Revalidation of Japanese Competent Authority Certificate J/159/AF-96.
USEC (United States Enrichment Corporation [now Centrus Energy]). 2017. The Uf6 Manual:
Good Handling Practices for Uranium Hexafluoride. Report No. USEC-651, Revision 10, Bethesda, MD.
Vaden, D. 2021. Isotopic Characterization of HALEU from EBR-II Driver Fuel Processing.
INL/EXT-18-51906-Revision-1, Idaho National Laboratory. Idaho Falls, ID.
https://inldigitallibrary.inl.gov/sites/sti/sti/Sort_46103.pdf.
WNN. 2022. First Contracts Awarded for Us Strategic Uranium Reserve. World Nuclear News.
https://www.world-nuclear-news.org/Articles/First-contracts-awarded-for-US-strategic-uranium-r.
Zipperer, T. J., D. V. Colamenco, and K. J. Geelhood. 2020. Criticality Safety and Fuel Performance Considerations for Enrichment above 5 Weight Percent in the Uranium Dioxide Fuel Cycle. PNNL-30088. Pacific Northwest National Laboratory, Richland, WA.