Letter Sequence Meeting |
|---|
|
|
MONTHYEARML24093A2662024-04-0303 April 2024 Notice of Pre-Application Meeting with Tn Americas, LLC for the Model No. Tn Eagle Package Project stage: Meeting ML24172A2042024-05-0101 May 2024 Enclosure 2: Tn Eagle - NRC Pre-Application Meeting Public Slides Project stage: Meeting ML24172A2022024-06-21021 June 2024 Memo and Enclosure 1 Summary of May 1, 2021 Meeting with Tn Americas, LLC Project stage: Meeting ML24193A2822024-07-11011 July 2024 Tn Americas LLC Application for Revision 1 to Certificate of Compliance No. 9382 for the Tn Eagle Transportation Package Project stage: Request ML24242A2582024-09-0303 September 2024 Amendment Request for Certificate of Compliance No. 9382 for the Model No. Tn Eagle - Acceptance for Review Project stage: Acceptance Review ML25006A1052025-01-13013 January 2025 Request for Additional Information for the Tn Eagle Package Amendment Request Project stage: Request ML25006A1062025-01-13013 January 2025 Tn Eagle Rev. 1 - Enclosure Request for Additional Information Project stage: RAI ML25006A1072025-01-13013 January 2025 Tn Eagle Rev. 1 - RAI Letter Project stage: RAI ML25072A2782025-05-27027 May 2025 Certificate of Compliance No. 9382, Revision 1 for the Model No. TN-Eagle Transportation Package Project stage: Request ML25072A2742025-05-27027 May 2025 Certificate of Compliance 71-9382. R1 for the Model No. Tn Eagle Package Project stage: Other ML25072A2752025-05-27027 May 2025 Certificate of Compliance No. 9382. R1. Safety Evaluation Report Project stage: Approval ML25072A2762025-05-27027 May 2025 Cover Letter - Certificate of Compliance No.9382, Rev. No. 1, for the Model No. Tn Eagle Package Project stage: Other 2024-07-11
[Table View] |
Text
TN EAGLE New CoC Revision Application NRC PRE-APPLICATION MEETING May 1st, 2024
© ORANO TN
2 Project Presentation The TN Eagle is a Universal Transport Cask developed by Orano TN and licensed for Transportation under NRC regulation 10 CFR Part 71, CoC 9382 Rev. 0 Identified contents are:
CoC 1042 - EOS Dry Shielded Canisters CoC 9255 - MP 187 Dry Shielded Canisters CoC 9302 - MP 197HB Dry Shielded Canisters A licensing application for a revision to CoC 9382 is planned to be submitted mid-2024 Non-Proprietary TN Eagle
3 Cask Presentation Single shell, forged body New technology for assembly and handling principles Non-Proprietary TN Eagle Forged body Assembly Impact Limiter Lid
4 Objectives of the amendment request Reconcile the licensed design with the as-fabricated design A neutron shielding resin with better temperature limit was used instead of the resin specified in the license A different paint with better resistance was used Various other minor changes were made to the design Criticality updates to expand an existing content and cover some DSCs already loaded Non-Proprietary TN Eagle