Other: ML23352A062, ML24211A073, ML24219A022, ML25030A384, ML25090A217, ML25163A050, ML25183A016, ML25191A213, ML25202A137, ML25202A139, ML25225A066, ML26076A164, PMNS20240525, Sufficiency Gaps Identified in EPRI Report 3002025288 on Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components
|
MONTHYEARPMNS20240072, Status of the NRC Staffs Review of EPRI Technical Report 3002025288 Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components (Risk-Informed Cmpbc)2024-01-31031 January 2024 Status of the NRC Staffs Review of EPRI Technical Report 3002025288 Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components (Risk-Informed Cmpbc) Project stage: Approval ML24044A0002024-02-12012 February 2024 EPRI Technical Report 3002025288 Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components - NRC Public Meeting, February 12, 2024 Project stage: Meeting PMNS20240272, U. S. Nuclear Regulatory Commission (NRC) Public Meeting with the Nuclear Energy Institute (NEI) to Discuss the Review of NEI-99-01, Rev. 7, Development of Emergency Action Levels for Non-Passive Reactors2024-03-12012 March 2024 U. S. Nuclear Regulatory Commission (NRC) Public Meeting with the Nuclear Energy Institute (NEI) to Discuss the Review of NEI-99-01, Rev. 7, Development of Emergency Action Levels for Non-Passive Reactors Project stage: Request ML24054A0062024-03-29029 March 2024 Summary of Meeting to Discussion the Status of the NRC Staffs Review of Technical Report 3002025288 Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Meeting ML24100A0682024-04-0909 April 2024 Submittal of NRC Draft Slides for 04/20/2024 Meeting on Sufficiency Gaps Identified in EPRI Report 3002025288 on Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components (L-2023-TOP-0031) ML24117A2962024-04-23023 April 2024 E-Mail - EPRI Forwards Slides for Public Meeting on 4/30/2024 EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Meeting PMNS20240525, Sufficiency Gaps Identified in EPRI Report 3002025288 on Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components2024-04-26026 April 2024 Sufficiency Gaps Identified in EPRI Report 3002025288 on Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Other ML24100A0702024-04-30030 April 2024 Draft Slides for 04/30/2024 Meeting on Sufficiency Gaps Identified in EPRI Report 3002025288 on Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components ML24117A2592024-04-30030 April 2024 EPRI Technical Report 3002025288 Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components - NRC Public Meeting - April 30, 2024 Project stage: Meeting ML24117A2562024-04-30030 April 2024 24-04-30 - Acceptance Review Status EPRI PRI TR 3002025288 Ri Cmpbc - NRC Slides Project stage: Acceptance Review ML24117A2792024-06-10010 June 2024 Meeting Summary to Discuss Sufficiency Gaps Identified in EPRI Report 3002025288 on Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Meeting ML23352A0622024-07-11011 July 2024 NRC Form 898, Topical Report Completeness Determination, for EPRI Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components (RI-CMPBC) (EPRI L-2023-TOP-0045) Project stage: Other ML23352A0582024-07-11011 July 2024 E-Mail - Acceptance of Electric Power Research Institute Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Acceptance Review ML24166A0912024-07-16016 July 2024 NEI 99-01 R7 Meeting Summary March 15 and April 16, 2024 Project stage: Meeting ML24219A0222024-08-0101 August 2024 Change in Estimated Review Schedule for Electric Power Research Institute Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Other ML24211A0732024-08-0808 August 2024 Change in Estimated Review Schedule for Electric Power Research Institute Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Other ML24241A1732024-08-30030 August 2024 Electric Power Research Institute Regulatory Audit in Support of Review of Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Revision 0 (EPID L?2023?TOP?0045) Project stage: Approval ML24241A1662024-08-30030 August 2024 E-mail - Electric Power Research Institute Regulatory Audit in Support of Review of Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Revision 0 Project stage: Approval ML24352A4382024-12-17017 December 2024 License Amendment Request to Revise Technical Specifications to Adopt TSTF-505-A, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b Commissioners Project stage: Request ML24352A4712025-01-13013 January 2025 E-Mail - Final Request for Additional Information - EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: RAI ML24352A4812025-01-13013 January 2025 Final Request for Additional Information - EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: RAI ML24352A4692025-01-13013 January 2025 Final Request for Additional Information - EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Request ML25030A3842025-01-30030 January 2025 License Amendment Required to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors Project stage: Other ML25063A2492025-03-0404 March 2025 Non Proprietary - EPRI 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, RAI Responses - Draft for Public Meeting Only PMNS20250244, Public Meeting Between NRC and EPRI to Discuss the Status of Request for Additional Information Associated with the NRC Staffs Review of Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Componen2025-03-0505 March 2025 Public Meeting Between NRC and EPRI to Discuss the Status of Request for Additional Information Associated with the NRC Staffs Review of Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: RAI ML25060A0012025-03-0606 March 2025 EPRI Slides for March 6, 2025, Public Meeting on EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Meeting ML25054A0012025-03-0606 March 2025 March 6, 2025, Public Meeting on Between NRC and EPRI on EPRI TR 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Requests for Additional Information Project stage: RAI ML25069A4712025-03-10010 March 2025 Acceptance Review - Wolf Creek Licensing Amendment Request to Adopt 10 CFR 50.69 Project stage: Acceptance Review ML25091A0932025-04-0101 April 2025 EPRI Report 3002025288 Requests for Additional Information Project stage: RAI PMNS20250361, Technical Discussion EPRIs Draft Responses to NRC Staff Issued Request for Additional Information for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components2025-04-0202 April 2025 Technical Discussion EPRIs Draft Responses to NRC Staff Issued Request for Additional Information for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Draft RAI ML25090A2172025-04-0202 April 2025 Regulatory Audit Plan in Support of License Amendment Requests to Adopt TSTF-505, Revision 2, and 10 CFR 50.69, Project stage: Other ML25078A2682025-04-29029 April 2025 Summary of Technical Discussion on EPRIs Draft Responses to NRC Staff Issued Request for Additional Information for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Draft RAI ML25163A0502025-06-11011 June 2025 EPRIs Thoughts and Response to the Limitations and Conditions in the Safety Evaluation for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Other PMNS20250719, Discussion Between NRC and EPRI on the Proposed Limitations/Conditions in the NRC Staffs Safety Evaluation for Proprietary Review for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Compon2025-06-11011 June 2025 Discussion Between NRC and EPRI on the Proposed Limitations/Conditions in the NRC Staffs Safety Evaluation for Proprietary Review for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Approval ML25162A1192025-06-11011 June 2025 E-mail - Proposed Limitations and Conditions to Be Contained in the Safety Evaluation for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Approval ML25162A1202025-06-11011 June 2025 Proposed Limitations and Conditions to Be Contained in the Safety Evaluation for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Approval ML25162A1172025-06-11011 June 2025 Proposed Limitations and Conditions to Be Contained in the Safety Evaluation for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Request ML25147A1232025-06-12012 June 2025 Regulatory Audit Report in Support of Review of Electric Power Research Institute Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Revision 0 (EPID L-2023-TOP-0045) Project stage: Approval ML25147A1222025-06-12012 June 2025 Email - Regulatory Audit Report in Support of Review of Electric Power Research Institute Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Revision 0 (EPID L-2023-TOP-0045 Project stage: Approval ML25147A1182025-06-12012 June 2025 Regulatory Audit Report in Support of Review of Electric Power Research Institute Technical Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, Revision 0 Project stage: Request ML25149A0112025-06-13013 June 2025 Transmittal of Safety Evaluation EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, for Proprietary Review (L-2023-NTR-0008) Project stage: Approval ML25191A2132025-06-27027 June 2025 EPRI Statement Indicating That There Is No Proprietary Information in the Safety Evaluation for EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components, for Proprietary Review (L-2023-NTR-0 Project stage: Other ML25183A0162025-07-0101 July 2025 CFR 50.69 Audit Questions (Apla) Dated July 1, 2025 Project stage: Other ML25168A0152025-07-15015 July 2025 Final Safety Evaluation EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components (L-2023-NTR-0008) Project stage: Approval ML25168A0142025-07-15015 July 2025 E-mail - Transmittal of Final Safety Evaluation EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components (L-2023-NTR-0008) Project stage: Approval ML25168A0112025-07-15015 July 2025 Transmittal of Final Safety Evaluation EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components (L-2023-NTR-0008) Project stage: Request ML25225A0662025-08-12012 August 2025 Email - Wolf Creek 10 CFR 50.69 Audit Questions (Aplc) Dated August 12, 2025 Project stage: Other ML25202A1372025-09-0909 September 2025 E-mail - Transmittal of NRC Form 896, -A Topical Report Verification, for EPRI Report Entitled Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Other ML25202A1312025-09-0909 September 2025 Transmittal of NRC Form 896, -A Topical Report Verification, for EPRI Report Entitled Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Request ML25202A1392025-09-0909 September 2025 NRC Form 896, -A Topical Report Verification, for EPRI Report Entitled Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Project stage: Other 2025-01-13
[Table View] |
Text
MEMORANDUM TO: Gerond A. George, Chief FROM:
Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Lois M. James, Senior Project Manager /RA/
Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
SUBJECT:
MEETING
SUMMARY
FOR APRIL 30, 2024, TO DISCUSS SUFFICIENCY GAPS IDENTIFIED IN ELECTRIC POWER RESEARCH INSTITUTE REPORT 3002025288 ON ENHANCED RISK-INFORMED CATEGORIZATION METHODOLOGY FOR PRESSURE BOUNDARY COMPONENTS (EPID NO. L-2023-TOP-0045)
On April 30, 2024, the U.S. Nuclear Commission (NRC) staff met with Electric Power Research Institute (EPRI) representatives to discuss sufficiency gaps identified in EPRI Report 3002025288 on enhanced risk-informed categorization methodology for pressure boundary components. The meeting summary is Enclosure 1 and the list of attendees is.
If you have any questions or comments, please contact me via e-mail at Lois.James@nrc.gov.
Docket No. 99902021
Enclosures:
1.
Meeting Summary 2.
List of Attendees CONTACT: Lois M. James, NRR/DORL/LLPB 301-415-3306 June 10, 2024 Signed by James, Lois on 06/10/24
U.S. Nuclear Regulatory Commission Public Meeting Summary
Title:
Sufficiency Gaps Identified in Electric Power Research Institute (EPRI)
Report 3002025288 on Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components Date of Meeting:
April 30, 2024 Location:
Hybrid Type of Meeting:
This was an Observation meeting in which attendees had an opportunity to observe the U.S. Nuclear Regulatory Commission (NRC) performing its regulatory function or discussing regulatory issues. Attendees had an opportunity to ask questions of the NRC staff or make comments about the issues discussed following the business portion of the meeting; however, the NRC was not actively soliciting comments toward regulatory decisions at this meeting.
Purpose of the Meeting:
To discuss the NRC's staff's sufficiency gaps in EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components.
General Details:
The NRC staff held a public, observational meeting with EPRI representatives to discuss the NRC's staff's sufficiency gaps in EPRI Report 3002025288, Enhanced Risk-Informed Categorization Methodology for Pressure Boundary Components. The meeting began at 10:00 am and ended 4:00 pm. There were thirty-seven NRC staff members, eight EPRI representatives, two Nuclear Energy Institute representatives, eight industry members, and three members of the public or individuals who did not identify an affiliation. The meeting began with introductions of the NRC staff and EPRI representatives.
Summary of Meeting:
The NRC staff began the meeting by identifying key messages:
1.
What is meant by a detailed technical basis, why having one documented is essential to start a detailed review of the TR, and the path forward to getting to one.
2.
An adequate, detailed technical basis is necessary to answer the whys of the proposed methodology.
3.
Answering the whys of the proposed methodology is not only essential for the current review, but for the use of the methodology going forward.
The NRC staff and EPRI representatives held a detailed discussion of the whys:
Why does this criterion exist in your methodology?
Why is this criterion written exactly this way?
EPRI representatives stated that they understand the NRC staffs questions and concerns and will provide a supplement to the EPRI Report 3002025288 by June 14, 2024.
Public Participation Themes:
No member of the public spoke at the hybrid meeting.
Action Items/Next Steps:
The NRC staff will prepare and issue a meeting summary.
Attachments:
Meeting description and agenda - ADAMS Accession No. ML24117A331 NRC slide presentation - ADAMS Accession No. ML24117A256 EPRI slide presentation - ADAMS Accession No. ML24117A259
ATTENDEE LIST MEETING ON APRIL 30, 2024, TO DISCUSS SUFFICIENCY GAPS IDENTIFIED IN EPRI REPORT 3002025288 ON ENHANCED RISK-INFORMED CATEGORIZATION METHODOLOGY FOR PRESSURE BOUNDARY COMPONENTS (EPID NO. L-2023-TOP-0045)
April 30, 2024 Name NRC Participants David Beaulieu U.S. Nuclear Reactor Regulations (NRC)
David Bennardo NRC Mihaela Biro NRC Billy Blaney NRC Steven Bloom NRC John Bozga NRC Adrienne Brown NRC Mat Burton NRC Stephen Cumblidge NRC James Delosreyes NRC Stephen Dinsmore NRC Mike Franovich NRC Gerond George NRC Todd Hilsmeier NRC Jo Jacobs NRC Lois James NRC Michael King NRC Andrea Kock NRC Samuel Lee NRC Kamal Manoly NRC Matthew Mitchell NRC Demetrius Murray NRC Ching Ng NRC Carol Nove NRC Robert Pascarelli NRC Amar Patel NRC Jamie Pelton NRC Bo Pham NRC April Pulvirenti NRC Aida Rivera-Varona NRC Anthony Rossi NRC David Rudland NRC Jeff Smith NRC Robert Taylor NRC Shilp Vasavada NRC Name NRC Participants Sunil Weerakkody NRC Dan Widrevitz NRC EPRI Participants Name Affiliation James Cirilli Electric Power Research Institute (EPRI)
Fernando Ferante EPRI Rick Fougerousse EPRI Doug Kull EPRI Ashley Lindeman EPRI Jim Moody EPRI Patrick O'Regan EPRI Michael Ruszkowski EPRI NEI Participants Name Affiliation Victoria Anderson Nuclear Energy Institute (NEI)
Thomas Basso NEI Industry Participants Name Affiliation Roy Llinthicum Consellation Nuclear Jeff Stone Consellation Nuclear Jana Bergman Curtiss-Wrights Nuclear Regulatory Services Heather Davis Szews Duke Energy Jennifer Varnedoe Duke Energy Bob Post Enercon Kenneth L. Fossum Idaho National Laboratory Bradley Dolan Tennessee Valley Authority Public Participants Name Affiliation 3 unidentified individuals
ML24117A279 (NRC and EPRI slides are listed in summary)
^via eConcurrence
- via email NRR-106 OFFICE DORL/LLPB/PM DORL/LLPB/LA DNRL/NPHP/BC DRA/APLA/BC NAME LJames^
DHarrison^
MMitchell*
BPascarelli^
DATE 06/05/2024 06/06/2024 06/10/2024 06/10/2024 OFFICE DORL/LLPB/BC DORL/LLPB/PM NAME GGeorge^
LJames^