NRC INSPECTION MANUAL NMSS/DFM INSPECTION MANUAL CHAPTER 1247 APPENDIX A BASIC-LEVEL TRAINING AND CERTIFICATION JOURNAL FUEL FACILITY INSPECTOR Effective Date: July 1, 2024

Issue Date: 07/01/24 i

1247 App A TABLE OF CONTENTS Introduction................................................................................................................................... 2 Program Organization................................................................................................................... 2 Required Basic-Level Training Courses....................................................................................... 3 Interpersonal Skills Training.......................................................................................................... 4 Technical Training......................................................................................................................... 4 Basic-Level Individual Study Activities.......................................................................................... 4 (SG-1) History and Organization of the Nuclear Regulatory Commission.............................. 7 (SG-2) Inspector Objectivity, Protocol, and Professional Conduct.......................................... 9 (SG-3) Allegations................................................................................................................. 12 (SG-4) NRCs Response to an Emergency at a Nuclear Facility.......................................... 14 (SG-5) The Enforcement Process and the Backfit Process.................................................. 16 (SG-6) The Office of Investigations....................................................................................... 19 (SG-7) Exploring the Fuel Facility Inspection Program......................................................... 20 (SG-8) Incident Inspection Team (IIT) Activities, Augmented Inspection Team (AIT), and Special Inspection Team (SIT).................................................................................. 22 (SG-9) Understanding How the Commission Operates........................................................ 24 (SG-10) Organization and Content of the NRC Inspection Manual...................................... 25 (SG-11) NRC Interagency Agreements................................................................................ 27 (SG-12) Interaction with the Public....................................................................................... 29 (SG-13) Contacts with the Media.......................................................................................... 32 (SG-14) Freedom of Information Act and the Privacy Act..................................................... 34 (SG-15) Entrance and Exit Meetings.................................................................................... 36 (SG-16) Documenting Inspection Findings........................................................................... 38 (SG-17) Differing Professional Opinions (DPO).................................................................... 40 (SG-18) Integrated Safety Analysis (ISA) Overview (not for MC&A inspectors)................... 42 (SG-19) Overview of 10 CFR Part 30................................................................................... 44 (SG-20) Overview of 10 CFR Part 40................................................................................... 45 (SG-21) Overview of 10 CFR Part 70................................................................................... 46 (SG-22) Overview of 10 CFR Part 71................................................................................... 47 (SG-23) Overview of 10 CFR Part 73................................................................................... 48 (SG-24) Overview of 10 CFR Part 74................................................................................... 50 (SG-25) Overview of 10 CFR Parts 19 and 20...................................................................... 51 (SG-26) Licensee-Specific Regulatory Documents and Procedures.................................... 53 (SG-27) Planning Fuel Facility Inspections........................................................................... 55 (SG-28) Information Security................................................................................................ 58 (OJT-1) Facility Familiarization Tour with a Qualified Inspector............................................ 62 (OJT-2) Licensee Performance Reviews (LPRs).................................................................. 65 (OJT-3) Inspection Activities................................................................................................. 66 (OJT-4) Documenting Inspection Findings............................................................................ 69 Basic-Level Signature Cards and Certification................................................... 71 Form 1: Basic-Level Equivalency Justification.................................................... 74 : Revision History for IMC 1247 Appendix A.................................................... Att1-1

Issue Date: 07/01/24 2

1247 App A INTRODUCTION The inspector training and qualification program requires that you complete a variety of activities, each of which is designed to help you learn information or practice a skill that will be important to performing the job of an inspector. When you have completed the entire qualification process, you will have demonstrated each of the competencies that describe a successful inspector.

A competent inspector must develop competencies in the following four areas. More details of these areas are provided in Attachment 2 of IMC 1247:

Area 1: Understand the legal basis and the regulatory processes for achieving the NRCs regulatory objectives.

Area 2: Understand the technology and apply concepts in various technical areas to allow the NRC to carry out its overall responsibilities.

Area 3: Master the techniques and skills needed to collect, analyze, and integrate information using a safety focus to develop a supportable regulatory conclusion.

Area 4: Have the personal and interpersonal skills to carry out assigned regulatory activities either individually or as a member of a team.

PROGRAM ORGANIZATION The inspector qualification process has two levels. The first level is the Basic-Level. Basic-level activities are designed to help you develop an awareness of the role of the Agency, your role as an inspector, and the technology you will be inspecting. Successfully completing the Basic-Level work will provide you with a context for meaningful learning during on-site work and a foundation for in-depth learning at the next level. After successfully completing the Basic-Level activities, you will receive Basic Inspector Certification with supervisory approval.

With a Basic Inspector Certification, you can be assigned to perform limited scope inspection activities under an appropriate degree of detailed oversight and supervision. The scope of your assigned inspection activities will be controlled by your immediate supervisor. Typically, your supervisor will review your work in detail at specified points during your qualification activities.

You can be asked to conduct inspection activities and develop independent conclusions which you will discuss with the lead inspector. You will not be expected to describe official agency positions on evolving issues, or act as an official agency spokesperson. The emphasis in the inspector qualification program is on competencies. There is no set time for completing each segment of the program nor do the on-the-job activities specify an exact number of times you must practice a task. You must practice until you can perform inspector tasks successfully in accordance with the evaluation criteria. Therefore, the time needed to complete all requirements to receive a Basic Inspector Certification will vary based on your previous education, training, and experience. Most employees will require several months to complete the work to be eligible to achieve Basic Inspector Certification.

The second level of the qualification process is the Proficiency-Level, which has two parts. One part is General Proficiency activities, which are designed to develop your interpersonal and inspection skills. The second part is Technical Proficiency activities, which are designed to develop your technical expertise in one of the inspector classifications. The final activity in the

Issue Date: 07/01/24 3

1247 App A Proficiency Level is to appear before a Qualification Board. You may work on the General and Technical Proficiency Journals at the same time. Successful completion of the Qualification Board will ensure that you have a sufficiently integrated understanding of the role of the Agency, the inspection program, and your role as an inspector to act independently in the field. Upon successful completion of all Proficiency Level activities, including the Qualification Board, you will receive Full Inspector Qualification, with Regional Administrator or Office Director approval.

This is expected to be completed in two years. As a fully qualified Inspector you will be assigned the full scope of inspection activities to perform independently.

There are three Qualification Journals (Basic-Level, General Proficiency-Level and Technical Proficiency-Level) you will need to complete during the inspector qualification process. Each journal identifies classroom requirements and provides individual study activities and on-the-job learning activities you must complete. The signature cards and certifications, which you will use to document your progress as you move through the Basic-and Proficiency-Levels, can be found at the end of each journal. Each journal also contains a form to document the justification for accepting equivalent training or experience as a means of meeting an inspector qualification requirement. The signature cards, certification pages, and equivalency justification pages will become the permanent record of your completion of the inspector qualification program and will be placed in your official file.

REQUIRED BASIC-LEVEL TRAINING COURSES These courses can be taken in any order, except for G-104S, which should be taken after you have completed the majority of the other work in this journal. After reviewing G-104S, meet with your supervisor to go over the case studies.

Fuel Cycle Processes/Directed Self-Study (F-201 or F-201S)

G-104S course here: http://papaya.nrc.gov/G-104/home.htm G-105 Conducting Reactor Inspections H-100S, Site Access Training Self-Study Course Ethics Training for New NRC Employees -Web-based as part of Individual Study Guide (SG) 2 Allegations Process Training - Web-based as part of SG-3 MCA-101DC, Intro to Nuclear Materials Control an Accountability (Required for Material Control and Accountability (MC&A) inspectors only)

MCA-104DB, Introduction to Measurement Programs (Required for MC&A inspectors only)

MCA-110, Basics of Nuclear Materials Accountability (Required for MC&A inspectors only)

MCA-120, Basics of Nuclear Materials Control (Required for MC&A inspectors only)

Issue Date: 07/01/24 4

1247 App A F-101S, Nuclear Criticality Safety Self-Study Course (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) OSHA HAZWOPER or web-based Health & Safety Training Suite1 (See ML100200563, for details of equivalent web-based training modules).

INTERPERSONAL SKILLS TRAINING The Interpersonal Skills Training Courses listed below are not required until the Proficiency Level for Full Inspector Qualification. However, they can be taken at any time during the inspector qualification process. Successful completion of any of these courses should be documented on the Signature Card in the General Proficiency Qualification Journal (IMC 1247 Appendix B). The trainee should review all applicable qualification cards to understand the training that is required so those courses can be scheduled as soon as possible (many courses are only given a few times a year or only when needed. There are also external training courses in IMC 1247 Appendix B and IMC 1247 Appendix C that will have to be requested, which can be a long process).

Effective Communication for NRC Inspectors Gathering Information for Inspectors through Interviews TECHNICAL TRAINING Technical training may be started at this level, provided that the training does not identify the successful completion of the Basic-Level as a prerequisite.

BASIC-LEVEL INDIVIDUAL STUDY ACTIVITIES The Individual Study Guides (SGs) are designed to direct and focus your efforts as you begin reviewing documents that will be important to the performance of your job. Each Study Guide begins with a purpose statement informing you of why the activity is important and how it relates to the job of an inspector. The level of effort has been noted so that you have an idea of how much effort should be expended in completing the activity. (Of course, the times are estimates.

You may need a little more or a little less time - but use the level of effort as an estimate.) The evaluation criteria are listed up front to improve understanding and retention. Use the evaluation criteria to help you to focus on what is most important. The tasks outline in detail the things you must do in order successfully address the evaluation criteria.

The following general guidance applies as you complete the various study activities:

1The 24hr OSHA HAZWOPER training requirement is intended for qualifying individuals who do not have adequate prior experience or training. Qualifying individuals with adequate experience must use the equivalency examination or equivalent experience justification process to alternatively opt for the web-based Health & Safety training suite.

Issue Date: 07/01/24 5

1247 App A SG-2 (Inspector Objectivity, Protocol, and Professional Conduct), and SG-3 (Allegations) should be completed prior to going on a site visit to a licensee facility or inspection accompaniment.

The first three SGs should be completed early during qualification, especially for individuals new to the NRC. Becoming familiar with the Agency, the internal and external web sites, and your overall role as an inspector is important for successfully completing many of the remaining SGs. You should also become familiar with the content of the remaining SGs so that you can complete the associated activities as opportunities arise.

Complete all parts of each SG.

Your supervisor will act as a resource as you complete each SG. Your supervisor may also designate other fully qualified individuals to work with you as you complete the various SGs.

Discuss any questions you may have about the content of anything you read with your supervisor or the person designated as a resource.

You are responsible for keeping track of what tasks you have completed. Be sure to complete all the tasks in each SG before meeting with your supervisor or the person designated as a resource for evaluation.

Issue Date: 07/01/24 6

1247 App A Basic-Level Individual Study Guides

Issue Date: 07/01/24 7

1247 App A (SG-1) History and Organization of the Nuclear Regulatory Commission PURPOSE:

The purpose of this activity is to familiarize you with the regulatory history of the commercial nuclear industry and the evolution of the regulatory framework under which todays NRC staff functions. During this activity you will review the organization of the agency and its staff and the relationships between the major offices. This SG should be completed early in the qualification process for newly hired staff.

COMPETENCY AREA: REGULATORY FRAMEWORK LEVEL OF EFFORT:

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />

REFERENCES:

Title 10 of the Code of Federal Regulations (10 CFR) Part 1 NUREG-1350, USNRC Information Digest (NUREGs are in the Document Collections section of the NRC Library on the public Web page, select the latest edition)

NUREG/BR-0175, A Short History of Nuclear Regulations, 1946-2009 Our History http://www.nrc.gov/about-nrc/history.html The NRC: An Agency Overview training course https://intranet.nrc.gov (offices tab)

EVALUATION CRITERIA:

Upon completion of this activity, you will demonstrate your understanding of the Agencys regulatory history and development of the commercial applications of nuclear energy, by successfully doing the following:

Discuss the purpose of the Atomic Energy Act of 1954, as amended.

Discuss the major regulatory impacts of the Energy Reorganization Act of 1974, as amended.

Outline the major offices and briefly describe the function of the following: The Commission; the Office of the Inspector General; Office of the Secretary of the Commission (SECY); the Atomic Safety Licensing Board; the Advisory Committee on Reactor Safeguards; Commission staff and Commission staff offices, including Chief Information Officer, Chief Financial Officer, Executive Director for Operations.

Describe your Regions or Offices organization and key management positions.

Issue Date: 07/01/24 8

1247 App A Discuss the missions of the NRC and the Department of Energy (DOE). How are they different? Why are they separate agencies?

TASKS:

Obtain the reference material listed above. Electronic copies can be found on the NRC External Website www.nrc.gov in the NRC Library or via the search bar.

Review the reference material to gain an understanding of the principles discussed in the evaluation criteria.

Complete the course in the Talent Management System (TMS) The NRC: An Agency Overview. Note: Two offices discussed in the course: The Office of New Reactors and The Office of Federal and State Materials and Environmental Management Programs, no longer exist as separate stand-alone organizations.

Review and discuss the evaluation criteria with your supervisor.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-1

Issue Date: 07/01/24 9

1247 App A (SG-2) Inspector Objectivity, Protocol, and Professional Conduct PURPOSE:

The purpose of this activity is to acquaint you with the NRCs expectations of inspector conduct and protocol. Objectivity and professionalism are essential to the Agency fulfilling its goals of protecting public health and safety. Inspector conduct is a vital component of the NRCs credibility as an effective regulator. As a qualified inspector, you will often be representing the Agency in interactions with licensee management and workers, local officials, media, and the public. This SG will help you understand NRC procedures, policies, and expectations related to inspector conduct. This activity will also help you develop the professional conduct that you will need to be an effective NRC inspector. You must complete this SG prior to going on a site visit or inspection accompaniment.

COMPETENCY AREA:

INSPECTION SELF-MANAGEMENT LEVEL OF EFFORT:

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> REFERENCES MD 7.5, Ethics, Counseling and Training Inspection Manual Chapter (IMC) 1201, Conduct of Employees NUREG/BR-0075, Field Policy Manual, (ML041170225) Policy No.10, Conduct of Employees, Policy No.13, Witnessing of Unsafe Situations and Policy No. 19, Guidance for Recommending Third Party Assistance to Licensees MD 8.17 Licensee Complaints Against NRC Employees IRP 244 Fuel Cycle Safety Group, Appendix G EVALUATION CRITERIA:

Upon completion of the tasks in this activity, you will demonstrate your understanding of proper NRC inspector conduct during inspections at nuclear facilities by successfully addressing the following:

1. What are the expectations of NRC employees regarding:
a. Alcohol and illegal drugs
b. Official business and personal relationships
c. Business partnerships with licensees
d. Work habits and professional demeanor

Issue Date: 07/01/24 10 1247 App A

2. Describe the restrictions regarding the following specific employee activities which could result in a loss of impartiality (or the perception thereof):
a. Accepting transportation from a licensee
b. Attending social functions essentially limited to licensee and contractor attendance
c. Coffee clubs, cafeterias, credit unions
d. Property and neighborhood relationships
e. Community activities
f.

Employment of spouse and children

3. Explain the Office of Government Ethics (OGE) standards of ethical conduct for the following areas as applicable to NRC inspectors:
a. Gifts from outside sources
b. Gifts between employees
c. Conflicting financial interests
d. impartiality in performing official duties
e. Seeking other employment
f.

Misuse of power

g. Outside activities
4. Explain the actions expected of NRC personnel when they identify unsafe work practices or violations which could lead to an unsafe situation.
5. Describe the overall requirements used by NRC managers to verify the performance and objectivity of individual inspectors and team leaders during on-site activities at fuel facilities.
6. Describe how NRC managers with responsibility for oversight of inspectors assess the performance and objectivity of those inspectors. Identify the specific areas that NRC management should focus on in assessing inspectors.
7. Describe the expectations for inspector conduct in a fuel facility control room during normal, transient, and emergency conditions. Identify any differences among facilities.
8. Describe what NRC employees are supposed to do if they receive an allegation of improper action by an NRC staff member or contractor involved in inspection or other oversight activities.
9. Describe the policy NRC employees should follow if requested to provide recommendations for third party assistance.

Issue Date: 07/01/24 11 1247 App A TASKS:

Complete the web-based Ethics Training. To access the training, select Ethics on NRCs Internal Website. Print the completion record at the end of the on-line ethics course. This must be presented to your supervisor as evidence that you have completed the course.

Review the material listed in the Reference section of this activity.

Identify, locate, and review your Regions or Offices policy guidance on inspector/employee conduct. Some of this guidance may be located in directives which describe the duties and responsibilities of specific positions (e.g., resident staff or project engineer guidance). You should closely review the guidance applicable to your position.

For assistance with identifying and locating these materials see your technical mentor or branch chief.

Review and discuss the evaluation criteria with your supervisor or designated ethics expert. Demonstrate your understanding of the NRCs expectations of inspector conduct and protocol by explaining the answers to the questions listed in the Evaluation Criteria section of this activity. Regional Counsel is considered one of the ethics experts.

Meet with your supervisor or other designated ethics expert to discuss the evaluation criteria and any questions you may have as a result of this activity.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-2

Issue Date: 07/01/24 12 1247 App A (SG-3) Allegations PURPOSE:

The purpose of this activity is to provide you with the opportunity to practice handling an allegation from receipt of the allegation to final disposition. This Study Guide will help you to effectively interact with individuals bringing concerns to the NRC and to appropriately respond to those concerns. You must complete this SG prior to going on a site visit or inspection accompaniment.

COMPETENCY AREA:

INSPECTION SELF-MANAGEMENT COMMUNICATION LEVEL OF EFFORT:

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />

REFERENCES:

MD 8.8, Management of Allegations ROI [Regional Office Instructions]-1030 and the Allegations Manual NRC Form 613, Allegation Program Identity Protection Policy Region or Office Allegation Coordinator NUREG/BR-0240, Reporting Safety Concerns to the NRC Office of Enforcement internal web page EVALUATION CRITERIA:

You will demonstrate your understanding of how to receive, process, and document an allegation by successfully completing allegation processing activities.

TASKS:

Complete the web-based training module on Allegations. Print the completion certificate at the end of the on-line allegations training. You must present the certificate to your supervisor as evidence that you have successfully completed the course.

Review the reference documents listed above for allegations.

Attend at least (2) allegation review boards (ARBs) which include both fuel facility and reactor allegations on the agenda. For staff located external to the regional office, participation in the ARB may be via teleconference.

Issue Date: 07/01/24 13 1247 App A Meet with the Allegation Coordinator and have them brief you on the allegation process and the Allegation Coordinators role in the process.

Review several allegation files (for closed allegations) and familiarize yourself with the documentation to the concerned individual. Due to limited resources staff located external to the regional office should review a minimum of one file.

Review how the original concern was brought to the NRCs attention.

Working with your Allegation Coordinator, simulate receiving an allegation and complete the required documentation to have the concern presented at an ARB meeting. Discuss with your Allegation Coordinator, a proposed inspection/review of the simulated allegation.

Discuss with your supervisor the options available to the NRC to follow up on an allegation and the circumstances when each are appropriate.

Obtain the inspection results and/or licensee review information for a concern that has been referred. Discuss the precautions and limitations associated with referrals with your supervisor or the Allegation Coordinator.

Compare the inspection results or licensee investigation results to the original concern.

Discuss with your supervisor how the inspection results addressed the concerns.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-3

Issue Date: 07/01/24 14 1247 App A (SG-4) NRCs Response to an Emergency at a Nuclear Facility PURPOSE:

The purpose of this activity is to acquaint you with the actions taken by the NRC in response to an emergency that may occur at a nuclear facility. Emergency response is vital to the Agency, fulfilling one of its primary mandates - protecting the health and safety of the public. As a fully qualified inspector, you will be trained to perform specific emergency response activities. This SG will help you to understand how the NRC meets its emergency response mandate and will begin to build the knowledge you will need later to successfully perform your assigned emergency response responsibilities.

COMPETENCY AREA:

EMERGENCY RESPONSE LEVEL OF EFFORT:

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />

REFERENCES:

NRC Internal Website - Program Office - Nuclear Security and Incident Response (NSIR)

MD 8.2, NRC Incident Response Program Regional Incident Response Procedures 201, 202, 204, and 244 Regional Guidance or Office Guidance (if applicable) https://usnrc.sharepoint.com/teams/Region-II-IRC Regulatory Guide 3.67, Standard Format and Content for Emergency Plans for Fuel Cycle and Materials Facilities, April 30, 2011 (ADAMS Accession Number ML103360487)

NRC External Website EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of the role of the Agency and your Region or Office in protecting public health and safety when responding to emergency situations at a nuclear facility by successfully addressing the following:

1. Identify the types of emergency classifications and give examples of when the different classifications would be declared.
2. Identify the different modes of NRC emergency response and describe the purpose of each mode.

Issue Date: 07/01/24 15 1247 App A

3. Discuss the responsibilities and operations of Headquarters, Regional, and onsite emergency response facilities during an emergency.
4. Recognizing that these positions may not apply to all nuclear facilities and that the NRC will act with all available resources to respond to an emergency, identify the responsibilities of the following during a declared emergency event:
a. Resident staff
b. Region-based staff
c. Headquarters Staff
d. Headquarters Operations Officer
e. Licensee
f.

State and Local officials

g. Site team
h. Base Team
5. Discuss the responsibilities/roles of region-based inspectors when onsite when an emergency occurs.

TASKS:

Explore all aspects of NSIRs organization presented on the NRCs Internal Website.

Review your Regions or Offices policy guidance on emergency response.

Review the NRC Incident Response Plan to address the evaluation criteria. Go to Emergency Preparedness on the NRC External Website and become familiar with the available information.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-4

Issue Date: 07/01/24 16 1247 App A (SG-5) The Enforcement Process and the Backfit Process PURPOSE:

The purpose of this activity is to provide you with an overview of the NRCs process for enforcing the Agencys rules and regulations. This SG will assist you in learning, understanding, and using the Agencys enforcement process for a wide variety of circumstances. It will also provide you with information on the internal activities used by the NRC for processing enforcement actions.

COMPETENCY AREA:

REGULATORY FRAMEWORK ASSESSMENT ENFORCEMENT LEVEL OF EFFORT:

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />

REFERENCES:

Enforcement Policy on NRC External Web site Enforcement Manual on NRC External Web site Interim Staff Guidance FCSS-ISG-12, Reportable Safety Events per 10 CFR Part 70 Appendix A Regional Guidance or Office Guidance (if applicable)

IMC 2606, Assessment of the Risk Resulting from a Potential Noncompliance at a Fuel Cycle Facility LIC-100, Control of Licensing Bases for Operating Reactors (1. Introduction,

2. Obligations)

LIC-504, Integrated Risk-Informed Decision-making Process for Emergent Issues NMSS-LIC-253, Backfit Guidance for the Office of Nuclear Material Safety and Safeguards (ML13161A115)

NUREG 1409, Backfitting Guidelines Management Directive 8.4, Management of Backfitting, Forward Fitting, Issue Finality, and Information Requests (ML18093B087)

TMS Training Backfitting and Issue Finality ROI 0926, Process for Dispositioning Escalated Enforcement

Issue Date: 07/01/24 17 1247 App A EVALUATION CRITERIA:

Upon completion of the tasks in this activity, demonstrate your understanding of the Agencys enforcement policy by successfully completing the following items:

State the purpose of the NRCs enforcement policy.

Describe the legal basis from which the NRC derives its enforcement authority.

Describe the term licensing basis and describe what makes something citable against a regulatory requirement.

Compare and contrast the different severity levels of violations.

Identify the method used to determine the significance of a violation.

Identify the method used to assign a severity level to a violation.

State the purpose of an enforcement panel.

State the purposes of a pre-decisional enforcement conference, written response, and alternative dispute resolution.

Discuss the purpose and use of enforcement actions against an individual.

Discuss the purpose of civil penalties and how to determine the amount of the penalty.

Recognize the purpose of the escalated enforcement process flow chart.

Recognize the purpose of the different types of Orders and when they are used.

Recognize the purpose of an Exercise of Discretion.

Define a backfit and what the attributes of a backfit are.

Discuss the NMSS Backfit Process Flowchart.

TASKS:

Review the overall enforcement process outlined on the NRC External Website by selecting Enforcement from the list under About NRC.

Locate the Enforcement Manual on the NRC External Website. Bookmark it for future use and review the table of contents.

Review your Regions or Offices guidance on implementing the enforcement policy.

Meet with the enforcement specialist in your Region or Office to discuss the current enforcement guidance.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

Issue Date: 07/01/24 18 1247 App A Review the NMSS-LIC-253, Backfit Guidance for the Office of Nuclear Material Safety and Safeguards and your Regions guidance on implementing the Backfit policy.

Observe an Enforcement Panel Meeting.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-5

Issue Date: 07/01/24 19 1247 App A (SG-6) The Office of Investigations PURPOSE:

The purpose of this activity is to familiarize you with the Office of Investigations (OI). As a fully qualified inspector you may be assigned to work with the Office of Investigations by providing technical support. This SG will help you to understand the role of OI, how it functions, and what your responsibilities will be if you are assigned to assist OI during the conduct of an investigation.

COMPETENCY AREA:

INSPECTION REGULATORY FRAMEWORK LEVEL OF EFFORT:

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

REFERENCES:

MD 9.8, Organization and Functions, Office of Investigations Regional Guidance or Office Guidance (if applicable)

Office of Investigations Website on the NRC External Website EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of the purpose and function of OI by successfully addressing the following:

State the function of OI.

Describe the organizational structure of OI.

Describe what your role would be in assisting OI.

Describe the authorities of an OI investigator.

TASKS:

Review MD 9.8, Organization and Functions, Office of Investigations.

Study the Office of Investigations website and associated organizational charts.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-6

Issue Date: 07/01/24 20 1247 App A (SG-7) Exploring the Fuel Facility Inspection Program PURPOSE:

The purpose of this Study Guide is for you to obtain a broad overall knowledge of the fuel fabrication facility program. Upon completion of this Study Guide, you will have the necessary background to go into a more detailed study of the inspection program, and learn the specifics of what an inspector does, why it is done, and how it is done.

COMPETENCY AREA:

INSPECTION REGULATORY FRAMEWORK LEVEL OF EFFORT:

30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />

REFERENCES:

IMC 2600, Fuel Cycle Facility Operational Safety and Safeguards Inspection Program IMC 2601, Reactive Inspection Decision Making Process for Fuel Facilities IMC 2604, Licensee Performance Review IMC 2681, Physical Protection and Transport of SNM and Irradiated Fuel Inspections of Fuel Facilities IMC 2683, MC&A Inspection of Fuel Cycle Facilities IMC 0616, Fuel Cycle Safety and Safeguards Inspection Reports IMC 0620, Inspection Documents and Records IMC 0330, Guidance for NRC Review of Licensee Draft Documents NRC external website - Fuel Cycle Facilities https://www.nrc.gov/materials/fuel-cycle-fac.html Regional Guidance or Office Guidance (if applicable)

IP 88020, Operational Safety EVALUATION CRITERIA:

After completing this Study Guide, you will demonstrate your understanding of the fuel facility inspection program by successfully doing the following:

State when the NRC starts implementing the operating inspection program at a site, and how long it remains in effect.

Issue Date: 07/01/24 21 1247 App A State the five major program elements of the fuel facility inspection program and their specific functions. Identify how often resources are assigned to each program element.

State the criteria for declaring that an inspection is complete.

State the purpose of providing an inspection-hours estimate in each procedure.

State the purpose and content of inspection reports.

State the general policy regarding an inspector's review and handling of non-NRC generated documents.

State the policy for announced and unannounced inspections and for controlling major inspection activities at a licensee's site.

Describe in general terms the implementation of the NRC's fuel facility assessment program (LPR).

NOTE: All inspection documents identified below can be obtained from the Document Collections section of the NRC Library on the public NRCs Website. (https://www.nrc.gov/reading-rm/doc-collections/index.html)

TASKS:

Locate the referenced IMCs. Read each in detail and scan the appendices to become aware of the organization of the inspection program including its major parts.

Locate IMC 0616, Fuel Cycle Safety and Safeguards Inspection Reports. Read the manual chapter to obtain a general understanding of the objectives of an inspection report; become familiar with the terminology, definitions, and the format of an inspection report; and have a general understanding of how inspection findings are addressed.

Locate IMC 0330, Guidance for NRC Review of Licensee Draft Documents and IMC 0620, Inspection Documents and Records. Scan the two manual chapters to obtain a general knowledge of the types of documents that will be encountered during an inspection and the NRC policy regarding how these documents should be handled.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-7

Issue Date: 07/01/24 22 1247 App A (SG-8) Incident Inspection Team (IIT) Activities, Augmented Inspection Team (AIT),

and Special Inspection Team (SIT)

PURPOSE:

The purpose of this activity is to familiarize you with the actions taken by the NRC in response to incidents that do not require activation of the NRC Incident Response Plan. As a fully qualified inspector, you may be assigned to an IIT, AIT or SIT inspection activity. This SG will help you to understand how the NRC implements this program, what your responsibilities will be if you are assigned to a team, what the differences are between an IIT, AIT and an SIT, and how this program differs from the NRC Incident Response Program.

COMPETENCY AREA:

INSPECTION LEVEL OF EFFORT:

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

REFERENCES:

Regional Guidance or Office Guidance (if applicable)

MD 8.3, NRC Incident Investigation Program Inspection Procedure (IP) 93800, Augmented Team Inspection IP 93812, Special Inspection EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of the NRCs IIT, AIT and SIT inspection activities by successfully addressing the following:

State the purpose of the NRCs Incident Investigation Program.

Describe what an IIT is and its purpose.

Describe what an AIT is and its purpose.

Describe what a SIT is and its purpose.

Describe how the Incident Investigation Program is different than the Incident Response Program.

TASKS:

Review MD 8.3. MDs can be found on the NRC Internal Website.

Issue Date: 07/01/24 23 1247 App A Explore all aspects of the Incident Investigation Program presented on the NRCs Internal Website.

Review your Regions or Offices guidance on IIT, AIT and AIT activities.

Meet with your supervisor, or the person designated to be your resource for this activity and discuss the answers to the questions listed under the Evaluation Criteria.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-8

Issue Date: 07/01/24 24 1247 App A (SG-9) Understanding How the Commission Operates PURPOSE:

The NRC Commissioners establish the approach the NRC staff will use to address a particular need of agency importance. Examples include the Commission policy statement regarding NRC staff use of Probabilistic Risk Analysis in the decision-making process and resident inspector staffing requirements at power reactor facilities. Since Commission decisions can have a significant impact on the conduct of inspection activities, inspectors should be familiar with the direction-setting and policy-making activities of the Commission.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

REFERENCES:

NRC External Website EVALUATION CRITERIA:

At the completion of this activity, you should be able to:

Locate Commission-related documents on the internal and external agency websites.

Discuss how staff requirements memoranda are used by the Commission to direct the staff.

TASKS:

Read about the Commissions Direction-Setting and Policy Making activities under the heading of About NRC.

Read about the different kinds of decision documents issued by the Commission.

Find and read Chairman Meserves speech given on 12/11/2001 about NRC Programs and Processes for Safety Oversight.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-9

Issue Date: 07/01/24 25 1247 App A (SG-10) Organization and Content of the NRC Inspection Manual PURPOSE:

The purpose of this activity is to introduce you to the contents and organization of the NRC Inspection Manual, and to how those contents relate to inspection programs, particularly the operating fuel facilities inspection program. As an inspector, you will be implementing an inspection program that is defined by a manual chapter and implemented by its associated inspection procedures. This SG will help you to identify and locate inspection procedures that are used in the fuel facilities inspection program and to recognize the limitations associated with applying the guidance contained in the procedures. This activity will also introduce you to manual chapters that establish policy which will govern some of your actions in implementing the fuel facilities inspection program.

COMPETENCY AREA:

REGULATORY FRAMEWORK INSPECTION LEVEL OF EFFORT:

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />

REFERENCES:

NRC Internal Home Page - Program Office - NMSS NRC External Website IMC 0040, Preparing, Revising and Issuing Documents for the NRC Inspection Manual EVALUATION CRITERIA:

After completing this activity, you will demonstrate your understanding of the content and organization of the NRC Inspection Manual, and the limitations associated with applying the guidance contained in the manual by successfully doing the following:

1. Identify the major parts of the NRC Inspection Manual.
2. State the purpose of each of the following types of documents located in the NRC Inspection Manual:
a. Manual Chapters
b. Inspection Procedures
c. Temporary Instructions
d. Technical Guidance
e. Change Notices (CN)
3. Describe the numbering/identification process used for the documents in item 2 above.

Issue Date: 07/01/24 26 1247 App A

4. Demonstrate the ability to locate copies of inspection documents contained in the NRC Inspection Manual on the internal and external websites.

TASKS:

1. Locate IMC 0040, Preparing, Revising and Issuing Documents for The NRC Inspection Manual in the NRC Library under Document Collections on the NRC External Website.
2. Review IMC 0040 paying close attention to section 7 (0040-07).
3. Locate the Table of Contents for the NRC Inspection Manual.
4. Scan the Table of Contents for the following:
a. The date of issuance and latest change notice entered in the Table of Contents.
b. Title associated with Part numbers.
c. The number associated with each document.
d. The issue date and CN number associated with each document.
5. Locate the section of the NRC Inspection Manual entitled Technical Guidance.
6. Scan the titles of the individual guidance documents.
7. Read the inspection procedures that apply to your inspector specialty area.
8. Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-10

Issue Date: 07/01/24 27 1247 App A (SG-11) NRC Interagency Agreements PURPOSE:

While conducting fuel facility inspection activities, inspectors may identify important issues that could adversely affect health and safety but are not under the direct regulatory authority of the NRC. Examples include industrial safety items, such as loose asbestos insulation, and other issues, such as defective radioactive waste shipping trailers. Conversely, other federal and state agencies may identify issues of concern to the NRC. To ensure these items are addressed by the proper regulatory authority, the NRC has established agreements, called memoranda of understanding (MOU), with other federal and state agencies which outline how these issues should be addressed.

This activity will introduce you to the major interagency agreements that the NRC has entered into and familiarize yourself with the regional or office points-of-contact that have been established for other federal and state agencies. It will also familiarize you with the inspection procedure which implements the Occupational Safety and Health Administration (OSHA) MOU.

COMPETENCY AREA:

INSPECTION REGULATORY FRAMEWORK LEVEL OF EFFORT:

4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

REFERENCES:

IMC 1007, Interfacing Activities Between Regional Offices of NRC and OSHA MOU section of the CFR Manuals NRC Internal Website EVALUATION CRITERIA:

At the completion of this activity, you should be able to:

1. Locate the active MOU used to coordinate between the NRC and other federal or state agencies.
2. Explain, in general terms, how the NRC coordinates with state and other federal agencies on matters that are not under the regulatory authority of the NRC.
3. Explain the actions required by an NRC inspector when he/she identifies an occupational health and safety issue at a fuel facility. Be able to state where the guidance for these actions is provided.
4. Identify who, in your Region or Office, is the point of contact for coordinating NRC activities with the following federal agencies:

Issue Date: 07/01/24 28 1247 App A

a. OSHA
b. Department of Transportation (DOT)
c. Federal Emergency Management Administration (FEMA)
d. DOE
e. State Agencies
f.

Federal Bureau of Investigation (FBI)

TASKS:

Identify where the current NRC MOUs are available in your Region or Office. Electronic versions can be found on the NRC Internal Website by accessing Topics, Information Resources, then Enforcement Manual.

Review the MOUs to develop a general understanding of the agreements between the NRC and the following federal agencies: OSHA, DOT, FEMA, DOE, and FBI with particular attention to the OSHA MOU. For Regional inspectors, reach out to your government liaison officer and review any MOUs between the NRC and the states in your regions. Determine the major services or resources available to be coordinated between the NRC and these agencies.

Review IMC 1007 to develop a general understanding of how the MOU with OSHA is implemented during an inspection.

Identify the designated liaison for those agencies and state agencies in your Region or Office.

Meet with your supervisor, an experienced qualified inspector, or the above liaison representative, and discuss two fuel facility issues that involved interface with other federal agencies or state agencies. Discuss how the issues were addressed in the context of the applicable NRC MOU and office guidance.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-11

Issue Date: 07/01/24 29 1247 App A (SG-12) Interaction with the Public PURPOSE:

The purpose of this activity is to acquaint you with the expectations of NRC inspectors when dealing with members of the public. Responsiveness and openness are essential to the Agency fulfilling its goal of enhancing public confidence. As a qualified inspector, you will have many opportunities to interact with the public. This SG will help you understand NRC procedures, policies, and available resources related to interaction with the public.

COMPETENCY AREA:

COMMUNICATION SELF-MANAGEMENT REGULATORY FRAMEWORK LEVEL OF EFFORT:

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

REFERENCES:

NUREG/BR 0215, Public Involvement in the Nuclear Regulatory Process NUREG/BR-0297, NRC Public Meetings NUREG-1379, NRC Style Guide MD 3.4, Release of Information to the Public MD 3.5, Attendance at NRC Staff Sponsored Meetings MD 8.11, Review Process for 10 CFR 2.206 Petitions ROI 1720, Policy for Staff Receipt and Processing of Inquiries from Media, Members of the Public and Others NRC External Website, Public Meetings and Involvement Regional or Office guidance related to interaction with the public (Conduct of public meetings, Response to inquiries from the public, Release of Information to the Public).

NOTE: NUREG references in this activity that cannot be found on the NRC External Website may be requested from your Public Affairs Officer (PAO).

EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of proper interaction with the public by successfully addressing the following:

Issue Date: 07/01/24 30 1247 App A

1. Describe the expectations of NRC employees regarding answering telephone calls or emails that involve inquiries from members of the public.
2. Name some resources available to assist you in responding to the following types of public inquiries:
a. General questions about NRC organization and functions
b. General questions about a technical topic such as radioactive particles
c. Questions about a licensed facilitys performance or an NRC inspection
d. Questions on a specific technical issue of current interest
3. Describe what is meant by Plain Language. Identify where examples and guidance related to plain language can be found.
4. Explain what a 2.206 petition is. Describe how it is handled by the NRC.
5. Describe how other public inquiries, including non-allegations, are handled in your office.
6. Describe what an NRC employee should do if he/she is requested to speak (on an NRC-related topic) at a meeting such as the Lions Club or local chapter of the American Nuclear Society.
7. Identify what types of NRC meetings are generally open to the public. List some that are not usually open to the public.
8. Describe how members of the public can find out about NRC public meetings. Discuss the expectations on timeliness of meeting notices and summaries.
9. Describe the restrictions regarding the release of information to the public including specific types of information that are not to be released.

TASKS:

Review the information presented by the NRC Public Affairs Office on interactions with the public on the NRCs Internal and External Websites. Review the information available on the external NRC website related to general topics of interest to the public such as the Public Involvement, School Programs, and the Technical Information Papers.

Visit the NRCs Plain Language Action Plan on the external website (Home/Public Involvement/Plain Writing/Plain Writing Action Plan, including some of the links to resource materials. Review the NRC Editorial Style Guide (NUREG-1379), section 7.

Visit the Communication and Public Meetings page on the NRC Internal Web site.

Review the public meeting policy and checklist.

Locate and review the material specifically listed in the Reference section of this activity.

The NMSS Project Managers Handbook and NUREG/BR-0200, Public Petition

Issue Date: 07/01/24 31 1247 App A Process may also be beneficial in understanding the processing of 2.206 petitions and ticketed items.

Review the steps in the rulemaking process on the NRCs External Website under Public Meetings & Involvement.

Identify, locate, and review your regions policy guidance on staff receipt and processing of inquiries from the general public (ROI 1720). Meet with your PAO or supervisor and discuss the expectations of an inspector who receives an inquiry.

Meet with your supervisor and discuss what types of public interactions you are likely to encounter and to ensure that you understand what you are to do. Then, discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-12

Issue Date: 07/01/24 32 1247 App A (SG-13) Contacts with the Media PURPOSE:

The purpose of this activity is to provide you with an understanding of the importance of communicating with the public and media in an accurate, clear, and non-complex manner and within the limitations of agency guidance for the release of information to the public. This supports one of the NRCs main objectives of increasing public confidence. This Study Guide will provide you information on the implementation of the guidance on contacts with the public and media.

COMPETENCY AREA:

COMMUNICATION SELF-MANAGEMENT LEVEL OF EFFORT:

4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

REFERENCES:

NUREG/BR-0202, Guidelines for Interviews with the Media MD 3.4, Release of Information to the Public NUREG/BR-0224, Guidelines for Conducting Public Meetings Regional or Office Instructions establishing the policy and process for receipt of inquiries from the public/media EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of the guidance on contacts with the media by successfully addressing the following:

Discuss the NRC goal of improving public confidence and how good communication with the media contributes to achieving that goal.

Identify the importance of communicating with the media in a manner to build trust.

Discuss the importance of the following up with media communications: agency goals, onsite inspection staff, safety focus, risk informed, trustworthiness, limited knowledge on the subject.

Discuss the importance of planning ahead and preparing well for communication with the media.

Discuss the importance of controlling your speech, including what words not to use, not speculating, not guessing, not answering the what if questions, not giving your opinion or repeating any other persons opinion, and not talking off the record.

Issue Date: 07/01/24 33 1247 App A Describe the policy and process for communicating to management any inquiries from or unplanned interactions with the news media and other members of the public.

NOTE: NUREG references in this activity that cannot be found on the NRC External Website may be requested from your PAO.

TASKS:

Meet with the regional PAO or someone from Office of Public Affairs at Headquarters to discuss the guidelines for interviews with the news media.

Explore all aspects of the importance of appropriate, accurate, and clear communications with the public provided in the reference material.

Review the agency guidance on how to communicate with the public and the media.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-13

Issue Date: 07/01/24 34 1247 App A (SG-14) Freedom of Information Act and the Privacy Act PURPOSE:

The purpose of this activity is to provide you with an understanding of the how the NRC implements the FOIA and the Privacy Act while guarding against the inadvertent and unauthorized release of information. While it is very important to communicate with the public, communication must be done within the limitations of agency guidance for the release of information to the public. This supports one of the NRCs main objectives of increasing public confidence. This SG will provide you information on the implementation of the guidance on responding to FOIA requests for information from the public.

COMPETENCY AREA:

COMMUNICATION SELF-MANAGEMENT REGULATORY FRAMEWORK LEVEL OF EFFORT:

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

REFERENCES:

10 CFR Part 2.390, Public inspections, exemptions, requests for withholding 10 CFR Part 9, Public Records MD 3.1, Freedom of Information Act MD 3.2, Privacy Act MD 3.4, Release of Information to the Public Regional or Office Instructions establishing the policy and procedure for processing FOIA requests for agency records NRC Sensitive Unclassified Non-Safeguards Information (SUNSI) policy http://www.internal.nrc.gov/OIS/divisions/irsd/SUNSI/index.html EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of the guidance on contacts with the media by successfully addressing the following:

1. Discuss the NRC goal of improving public confidence and how implementing the provisions of FOIA and the Privacy Act will contribute to achieving that goal.
2. Identify the completeness and timeliness requirements for responding to an FOIA request and discuss how important this responsiveness is in building public trust.
3. Discuss the following responsibilities when responding to a FOIA request:

Issue Date: 07/01/24 35 1247 App A

a. Provide all records subject to the request in the Agencys possession;
b. Identify other NRC offices that might have records subject to the FOIA request;
c. Screen the records prior to release to ensure that non-public information is properly marked prior to forwarding to FOIA coordinator; and
d. Support the decision to withhold information by providing the appropriate exemption and foreseeable harm statements.
4. Identify the type of information which should be withheld from release when responding to an FOIA request, including proprietary, pre-decisional, and privacy information.
5. Describe the legal limitations of what can be released to the public and what must be protected under the Privacy Act.
6. Describe the policy and procedure for processing FOIA requests for agency records.
7. Discuss the process and criteria for evaluating a withholding request submitted under 10 CFR Part 2.390.

TASKS:

Meet with the FOIA Coordinator to discuss the procedure for processing FOIA requests for agency records.

Explore the information made available to the public on the NRCs Website and via the Agencywide Document Access and Management System (ADAMS).

Review the agency guidance on how to implement the FOIA without releasing pre-decisional information and other information covered under the Privacy Act.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-14

Issue Date: 07/01/24 36 1247 App A (SG-15) Entrance and Exit Meetings PURPOSE:

Effective communication is critical for overall Agency success. While continuous communications with licensees is important, the inspection entrance and exit meetings are essential forums for communicating inspection issues with licensees. In addition to communicating effectively, as government officials, inspectors have additional requirements to follow during entrance and exit meetings to ensure proprietary data and safeguard information are not disclosed, and information is shared with the public when appropriate. To ensure issues are discussed in accordance with NRC requirements, communication standards have been established that outline how entrance and exit meetings are to be conducted. The purpose of this SG is to introduce you to the standards for conducting NRC entrance and exit meetings and to allow you to demonstrate an ability to conduct an entrance and exit meeting.

COMPETENCY AREA:

COMMUNICATION TEAMWORK INSPECTION LEVEL OF EFFORT:

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

REFERENCES:

IMC 2600, Fuel Cycle Facility Operational Safety and Safeguards Inspection Program IMC 2515, Light-Water Reactor Inspection Program - Operations Phase section 12 general inspection policies Regional Guidance or Office Guidance (if applicable)

EVALUATIONCRITERIA:

At the completion of this activity, you should be able to:

Locate the various guidance for conducting NRC entrance and exit meetings.

Successfully conduct an entrance and exit meeting in accordance with NRC guidance.

TASKS:

Locate and review the guidance for conducting NRC entrance and exit meetings contained in IMC 2600 and regional or office instructions.

Observe at least one entrance and exit meeting conducted at a fuel facility. If possible, observe meetings that have been conducted for a wide range of inspection activities in a variety of forums, such as a public exit meeting.

Issue Date: 07/01/24 37 1247 App A Review a recently completed inspection report and conduct a mock entrance and exit meeting of the inspection report findings in the presence of your supervisor or a fully qualified inspector designated by your supervisor.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-15

Issue Date: 07/01/24 38 1247 App A (SG-16) Documenting Inspection Findings PURPOSE:

NRC inspection reports serve many important functions. In addition to serving as a vehicle to communicate inspection findings to a licensee, inspection reports form part of the historical record of NRC activities at a fuel facility. To that end, it is vital for inspection reports to clearly document the results of inspection activities conducted. To assist inspectors in the preparation of inspection reports, the NRC has developed several guidance documents, which outline what information should be documented in an inspection report, and how that information should be presented. The purpose of this SG is to introduce you to the standards for preparing NRC inspection reports and to allow you to demonstrate an understanding of the applicable inspection report documentation requirements.

COMPETENCY AREA:

INSPECTION SELF-MANAGEMENT COMMUNICATION TEAMWORK ASSESSMENT AND ENFORCEMENT LEVEL OF EFFORT:

16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />

REFERENCES:

IMC 0616, Fuel Cycle Safety and Safeguards Inspection Reports IMC 0620, Inspection Documents and Records Regional Guidance or Office Guidance (as applicable)

EVALUATION CRITERIA:

At the completion of this activity, you should be able to:

Locate the guidance for preparing NRC inspection reports.

Verify an inspection report was written in accordance with the applicable NRC guidance.

Explain the threshold for documenting licensee and NRC identified issues in NRC inspection reports.

TASKS:

Locate and review the various guidance for documenting inspection findings. The necessary information will be contained in NRC IMCs, and regional or office instructions.

Issue Date: 07/01/24 39 1247 App A Select a recently completed inspection report that was prepared in your region or office that contains both NRC and licensee identified findings. Compare the inspection report format and content to the report preparation guidance contained in IMC 0616, and to any applicable regional or office guidance. Through review of the guidance, and conversations with the report author, verify the report was prepared in accordance with the requisite report preparation guidance.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-16

Issue Date: 07/01/24 40 1247 App A (SG-17) Differing Professional Opinions (DPO)

PURPOSE:

The purpose of this activity is to provide guidance on the informal and formal processes for pursuing resolution of differing professional opinions. It is the policy of the NRC and the responsibility of all NRC supervisory and managerial personnel to maintain a working environment that encourages each employee to make known his/her best professional judgment even though that judgment may differ from the prevailing staff view, disagree with a management decision or policy position, or take issue with proposed or established agency practices. Employees have various mechanisms for expressing and having their concerns and differing views heard and considered by management, including the Open-Door Policy, the Non-Concurrence Process (NCP), and the Differing Professional Opinion (DPO) Program. This SG will provide you with an understanding of these processes.

COMPETENCY AREA:

INSPECTION SELF-MANAGEMENT COMMUNICATION LEVEL OF EFFORT:

2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />

REFERENCES:

MD 10.158, NRC Non-Concurrence Process MD 10.159, The NRC Differing Professional Opinions Program MD 10.160, Open Door Policy NCP web site: https://usnrc.sharepoint.com/teams/NRC-non-concurrence-process DPO Program web site https://usnrc.sharepoint.com/teams/NRC-differing-professional-opinions Regional Guidance or Office Guidance (if applicable)

EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of NRCs DPO process by successfully addressing the following:

Describe the key features of the NCP.

Describe the Open-Door Policy.

Define what a DPO is and discuss the precondition that should be met prior to submittal.

Issue Date: 07/01/24 41 1247 App A State the expectations of NRC employees regarding making known their best professional judgment even though it may differ from the judgment of others.

Discuss under what circumstances the various methods available for expressing your best professional judgment would be used, including DPO.

State the purpose of the NRCs DPO process.

Describe the Agencys DPO process and how it is implemented.

Describe where the resolution of the resolution of a DPO is published.

TASKS:

Meet with the regional counsel, or other individual designated to be your resource for this activity, to develop an understanding of the NRC policy and guidance for resolution of differing professional opinions.

Review the Agencys MD 10.159, The NRC Differing Professional Opinions Program.

Explore all aspects of the Agencys DPO guidance and documentation provided on the NRCs internal website.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-17

Issue Date: 07/01/24 42 1247 App A (SG-18) Integrated Safety Analysis (ISA) Overview (not for MC&A inspectors)

PURPOSE:

The NRC, in 10 CFR Part 70, Subpart H, requires licensees to evaluate the risks associated with their facilities and to implement measures to ensure that the risks are limited. The NRC has defined high and intermediate consequence events in 10 CFR Part 70.61, Performance Requirements, and requires the licensees to implement Items Relied on For Safety (IROFS) to ensure the risk of the event is highly unlikely or unlikely, respectively. Changes to the facility must be evaluated to ensure no additional risks are created. Safety events are required to be reported to the NRC.

COMPETENCY AREA:

INSPECTION REGULATORY FRAMEWORK LEVEL OF EFFORT:

40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br />

REFERENCES:

10 CFR Part 70, Subpart H, Additional Requirements for Certain Licensees Authorized to Possess a Critical Mass of Special Nuclear Material The License Application and Integrated Safety Analysis (ISA) for the facility designated by your supervisor (Optional) Procedures used by the licensee at your designated facility to implement the ISA methodology Chapter 3 of NUREG-1520, Standard Review Plan for the Review of a License Application for a Fuel Cycle Facility (ML020930033)

EVALUATION CRITERIA:

At the completion of the guide, you should be able to do the following:

Explain the performance requirements of 10 CFR 70.61.

Explain how the IROFS and Management Measures contribute to risk reduction and accident mitigation, and how they factor into the ISA.

Explain the process used, in the ISA designated by your supervisor, to establish accident scenarios, likelihoods, consequences, and determine IROFS.

Explain the process for facility changes as described in 10 CFR Part 70.72.

Explain the NRC reporting requirements listed in 10 CFR Part 70, Appendix A.

Issue Date: 07/01/24 43 1247 App A TASKS:

1. Read 10 CFR Part 70, Subpart H, parts 61 through 74.
2. Read the following sections from the License Application for your assigned facility:
a. Integrated Safety Analysis (typically section 3)
b. Management Measures (typically section 11)
3. Read the introductory chapter of the ISA for your assigned facility and a chapter on a selected process or area.
4. (Optional) If available, obtain and review the implementing procedure used by the licensee at your assigned facility for the ISA methodology (evaluating hazards, identifying IROFS, and implementing facility changes).
5. Discuss with your supervisor, or a qualified Fuel Facility Operations inspector, the ISA Methodology used by your assigned facility licensee. Include in the discussion the following topics:
a. Performance Requirements
b. IROFS
c. Management Measures
d. Facility Change Process
e. Reporting Requirements.

DOCUMENTATION:

Basic-Level Qualification Signature Card Item SG-18

Issue Date: 07/01/24 44 1247 App A (SG-19) Overview of 10 CFR Part 30 PURPOSE:

The purpose of this activity is to acquaint you with the regulations that specify the requirements for all aspects of the rules governing domestic licensing of byproduct material. This SG will help you to understand the content of Part 30 and how to locate the specific requirements for any subject.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

REFERENCES:

NRC Internal Website 10 CFR Part 30, latest revision, Rules of General Applicability to Domestic Licensing of Byproduct Material EVALUATION CRITERIA:

Upon completion of the tasks in this activity, you will be asked to demonstrate your understanding of the general content of 10 CFR Part 30 by successfully discussing the following:

State the purpose of Part 30.

TASKS:

Become familiar with using the search feature to locate, the information available in NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-19

Issue Date: 07/01/24 45 1247 App A (SG-20) Overview of 10 CFR Part 40 PURPOSE:

The purpose of this activity is to acquaint you with the regulations that specify the requirements for all aspects of the Domestic Licensing of Source Material. This SG will help you to understand the content of Part 40 and how to locate the specific requirements for any subject.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

REFERENCES:

NRC Internal Website 10 CFR Part 40, latest revision, Domestic Licensing of Source Material EVALUATION CRITERIA:

Upon completion of the tasks in this activity, you will be asked to demonstrate your understanding of the general content of 10 CFR Part 40 by successfully discussing the following:

State the purpose of Part 40.

Given a specific subject, identify which section in Part 40 discusses the requirements for that subject by using the search feature on the NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

TASKS:

Become familiar with using the search feature to locate the information available in NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-20

Issue Date: 07/01/24 46 1247 App A (SG-21) Overview of 10 CFR Part 70 PURPOSE:

The purpose of this activity is to acquaint you with the regulations that specify the requirements for all aspects of Domestic Licensing of Special Nuclear Material. This SG will help you to understand the content of Part 70 and how to locate the specific requirements for any subject.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />

REFERENCES:

NRC Internal Website 10 CFR Part 70, latest revision, Domestic Licensing of Special Nuclear Material EVALUATION CRITERIA:

Upon completion of the tasks in this activity, you will be asked to demonstrate your understanding of the general content of 10 CFR Part 70 by successfully discussing the following:

State the purpose of Part 70.

Given a specific subject, identify which section in Part 70 discusses the requirements for that subject by using the search feature on the NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

TASKS:

Become familiar with using the search feature to locate the information available in NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-21

Issue Date: 07/01/24 47 1247 App A (SG-22) Overview of 10 CFR Part 71 PURPOSE:

The purpose of this activity is to acquaint you with the regulations that specify the requirements for all aspects of Packaging and Transportation of Radioactive Material. This SG will help you to understand the content of Part 71 and how to locate the specific requirements for any subject.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

REFERENCES:

NRC Internal Website 10 CFR Part 71, latest revision, Packaging and Transportation of Radioactive Material EVALUATION CRITERIA:

Upon completion of the tasks in this activity, you will be asked to demonstrate your understanding of the general content of 10 CFR Part 71 by successfully discussing the following:

State the purpose of Part 71.

Given a specific subject, identify which section in Part 71 discusses the requirements for that subject by using the search feature on the NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

TASKS:

Become familiar with using the search feature to locate the information available in NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-22

Issue Date: 07/01/24 48 1247 App A (SG-23) Overview of 10 CFR Part 73 PURPOSE:

The purpose of this activity is to acquaint you with the regulations that specify the requirements for all aspects of the Physical Protection of Plants and Materials. This SG will help you to understand the content of Part 73 and how to locate the specific requirements for any subject.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

REFERENCES:

NRC Internal Home Page 10 CFR Part 73, latest revision, Physical Protection of Plants and Materials 10 CFR Part 26, Fitness for Duty Program Enforcement Manual, Chapter 2.4, Enforcement Actions Involving Fitness for Duty EVALUATION CRITERIA:

Upon completion of the tasks in this activity, you will be asked to demonstrate your understanding of the general content of 10 CFR Part 73 by successfully discussing the following:

State the purpose of Part 73.

Given a specific subject, identify which section in Part 73 discusses the requirements for that subject by using the search feature on the NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

State the Purpose of the NRCs Fitness for Duty Rule and which licensees are required to meet the rule Explain why the Fitness for Duty Rule (10 CFR Part 26) does not apply to NRC staff and what considerations are used instead TASKS:

Become familiar with using the search feature to locate, the information available in NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

Read the information on the NRCs fitness for duty and drug testing program.

Issue Date: 07/01/24 49 1247 App A Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-23

Issue Date: 07/01/24 50 1247 App A (SG-24) Overview of 10 CFR Part 74 PURPOSE:

The purpose of this activity is to acquaint you with the regulations that specify the requirements for all aspects of Material Control and Accounting of Special Nuclear Material. This SG will help you to understand the content of Part 74 and how to locate the specific requirements for any subject.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

REFERENCES:

NRC Internal Website 10 CFR Part 74, latest revision, Material Control and Accounting of Special Nuclear Material EVALUATION CRITERIA:

Upon completion of the tasks in this activity, you will be asked to demonstrate your understanding of the general content of 10 CFR Part 74 by successfully discussing the following:

State the purpose of Part 74.

Given a specific subject, identify which section in Part 74 discusses the requirements for that subject by using the search feature on the NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

TASKS:

Become familiar with using the search feature to locate, the information available in NRC public website under NRC Library/Document Collections/Regulations (10 CFR)

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-24

Issue Date: 07/01/24 51 1247 App A (SG-25) Overview of 10 CFR Parts 19 and 20 PURPOSE:

The purpose of this activity is to familiarize you with Parts 19 and 20 of the NRC regulations.

These regulations are generic to any position within the Agency and will provide a perspective on conducting inspections in the working environment of a fuel facility. This SG will help you understand the purpose of Parts 19 and 20 and provide you with some basic knowledge that all NRC inspectors will use when conducting inspections in radiologically controlled areas.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />

REFERENCES:

NRC Internal Website 10 CFR Part 19, Notices, Instructions, and Reports to Workers: Inspection and Investigations 10 CFR Part 20, Standards for Protection Against Radiation EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your general understanding of Parts 19 and 20 and why these regulations are important for all inspectors, by successfully addressing the following:

Describe the general purpose of Part 19.

Identify the section of Part 19 that describes the rights of radiation workers if they believe a violation of radiological working condition requirements has occurred.

Identify the section of Part 19 that requires a licensee to report doses to workers.

Describe the purpose of Part 20.

Identify the section and discuss the various radiological circumstances that would require a licensee to notify the NRC.

Discuss why it is important for every NRC inspector to have a general understanding of Part 19 and 20.

TASKS:

1. Review Part 19 for a general understanding of the following:

Issue Date: 07/01/24 52 1247 App A

a. The purpose of Part 19 (19.1)
b. Documents are required to be posted (19.11[d] and [e])
c. Requirements for promptly identifying any condition that may cause unnecessary exposure (19.12[a][4])
d. Instructions for individuals in a restricted area that may experience unnecessary exposure to radiation and/or radioactive materials (19.12[a][5])
e. What times the NRC can inspect a facility (19.14[a])
f.

Requests by workers for an NRC inspection (19.16[a])

2. Review Part 20 for a general understanding of the following:
a. The purpose of Part 20 (20.1001)
b. Occupational dose limits for adults (20.1201)
c. Occupational dose limits for members of the public (20.1301)
d. Concepts of ALARA (20.1101)
e. Conditions requiring individual monitoring of external and internal occupational dose (20.1502)
3. Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-25

Issue Date: 07/01/24 53 1247 App A (SG-26) Licensee-Specific Regulatory Documents and Procedures PURPOSE:

The purpose of this activity is to acquaint you with licensee-specific documents and procedures that you need to be aware of and be able to access while onsite during an inspection. These documents and procedures describe how a licensee complies with NRC regulations and requirements. As a fully qualified inspector, you will need to identify circumstances where the licensee is in non-compliance. Also, inspectors must always adhere to applicable licensee procedures while onsite. This SG will acquaint you with the most common types of licensee-specific regulatory documents and procedures and will help you learn how individual facilities may implement NRC regulations and requirements differently.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />

REFERENCES:

License application for one fuel facility NUREG-1520. Standard Review Plan for Review of a License Application for a License Application of a Fuel Cycle Facility (ML020930033)

Facility-specific license Facility-specific Safety Evaluation Report EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your familiarity with the role of licensee-specific regulatory documents and procedures within the regulatory framework by successfully addressing the following:

1. Identify the regulatory enforcement hierarchy that exists between CFR requirements, a facility-specific license, facility-specific license application, and Safety Evaluation Report (SER), and facility-specific procedures.
2. Recognize how the NRC Standard Review Plan is related to the documents identified in item 1.
3. Identify which NRC organization writes safety analyses, which organization approves them, and which organization is required to maintain current copies.
4. Identify the NRC organization responsible for writing Regulatory Guides and Safety Evaluation Reports, and the organization responsible for approving them. Describe the requirements for maintaining copies current.

Issue Date: 07/01/24 54 1247 App A

5. Discuss how enforcement actions relate to safety analysis reports or an SER.
6. Locate where the following can generally be found:
a. Licensee commitments to various standards
b. Specific, but not necessarily all, approved methods for complying with NRC requirements
c. Licensee Security Plan TASKS:

Locate all applicable reference documents.

Meet with an appropriately qualified inspector and discuss the general objectives of a licensee security plan and the restrictions on its public availability. Also, determine the specific security requirements to which an NRC inspector must personally adhere.

Discuss with your Office Enforcement Specialist your answers to the above questions related to enforcement policy.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-26

Issue Date: 07/01/24 55 1247 App A (SG-27) Planning Fuel Facility Inspections PURPOSE:

This guide will familiarize you with a working knowledge of how to plan for fuel facility inspections and assist in identifying guidance documents for review. This applies to fuel facility inspectors conducting routine inspections of fuel fabrication facilities, uranium conversion facilities and uranium enrichment facilities.

COMPETENCY AREA:

INSPECTION PLANNING LEVEL OF EFFORT:

40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br />

REFERENCES:

10 CFR Part 40, Domestic Licensing of Source Material (particularly Part 40.64) 10 CFR Part 70, Domestic Licensing of Special Nuclear Material (particularly Part 10 CFR Part 19, Notices, Instructions, and Reports to Workers: Inspection and Investigations 10 CFR Part 20, Standards for Protection against Radiation 10 CFR Part 71, Packaging and Transportation of Radioactive Material 10 CFR Part 73, Physical Protection of Plants and Materials 10 CFR Part 74, Material Control and Accounting of Special Nuclear Material 29 CFR Part 1910, Occupational Safety and Health Standards 49 CFR Parts 170-189, Transportation The License Application, ISA, Safety Analysis Report (SAR), Quality Assurance Program Description (QAPD) (for URENCO only) for the facility designated by your supervisor.

Applicable IPs Applicable classified and sensitive unclassified non-safeguards information (SUNSI) information (talk to your supervisor about getting into the secure room)

Procedures used by the licensee at your designated facility to implement the ISA methodology.

NUREG-1513, Integrated Safety Analysis Guidance Document. (ML011440260)

NUREG-1520, Standard Review Plan for the Review of a License Application for a Fuel Cycle Facility. (ML020930033)

Issue Date: 07/01/24 56 1247 App A Previous Licensee Performance Review Previous applicable inspection reports from areas lasted inspected Materials Operational Experience Gateway (internal) https://usnrc.sharepoint.com/teams/NMSS-Fuel-Cycle-Operating-Experience/Lists/Fuel%20Cycle%20Events/AllItems.aspx?OR=Teams%2DHL&CT=163 9680119306)

Regional Office Instruction 2211, Inspection Planning for Reactors and Fuel Facilities.

(ML051440266)

EVALUATION CRITERIA:

At the completion of the study guide, you should be able to do the following:

Identify the appropriate inspection procedures needed for the inspection.

Identify the applicable regulations and guidance documents for inspection.

Determine the focus of the inspection based on risk, regulations, and license requirements.

Determine the relationship between the purpose and objectives in the inspection procedures to the licensing basis documents.

TASKS:

Review the applicable regulations for the facility.

Review the License Application/Safety Analysis Report, ISA, Fundamental Nuclear Material Control Plan (FNMCP), QAPD (URENCO only) and/or other licensing basis documents for your assigned facility appropriate to the inspection you are planning for.

Review the introductory chapter of the ISA for your assigned facility and a chapter on a selected process or area that will be inspected. (i.e., evaluating hazards, identifying IROFS, and implementing facility changes).

Review the applicable last two inspection reports.

Review the previous Licensee Performance Review of the facility.

(Optional) If available, obtain and read the implementing procedure for the area of inspection used by the licensee at your assigned facility.

Discuss with your supervisor or a qualified Fuel Facility inspector; questions concerning the license application/other licensing basis documents, previous inspections, event notifications (EN), Information Notices, and ISA methodology. Work with your supervisor to determine how far back in time to go when reviewing these documents.

Issue Date: 07/01/24 57 1247 App A Familiarize yourself with the Master Inspection Plan (MIP) and schedule.

Familiarize yourself with the Inspection Plan form Learn how to use Reactor Program System (RPS). You should practice RPS activities in the RPS test-environment.

Create inspection plans and reports in the RPS test-environment Practice finding/evaluating NMED reports.

Develop a mock inspection plan and review with your supervisor or a qualified Fuel Facility Operations inspector.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Qualification Signature Card Item SG-27

Issue Date: 07/01/24 58 1247 App A (SG-28) Information Security PURPOSE:

The purpose of this activity is to familiarize you with the different types and levels of classified information. This SG will help you to understand the fundamental rules and responsibilities to properly identify, mark, handle, store, transmit, reproduce, and destroy classified and Safeguards Information. This activity will also provide the inspector with knowledge of the NRC policy for handling, marking, and protecting SUNSI.

COMPETENCY AREA:

REGULATORY FRAMEWORK LEVEL OF EFFORT:

16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />

REFERENCES:

NRC Internal Web Page MD 12.2, NRC Classified Information Security Program MD 12.6, NRC Sensitive Unclassified Information Security Program 10 CFR Part 73, Physical Protection of Plants and Materials NRC Sensitive Unclassified Non-Safeguards Information (SUNSI) policy (https://usnrc.sharepoint.com/sites/SUNSI) (internal)

EVALUATION CRITERIA:

Upon completion of this activity, and as determined by the supervisor the inspector should be able to:

Describe the different types and levels of classified information.

Explain the need for maintaining classification of certain material safeguards and the proper handling of the material.

Describe the NRC policy for handling, marking, and protecting SUNSI.

Describe handling of classified and sensitive unclassified information originating outside of NRC.

TASKS:

Complete the Information Security Awareness Training in web-based TMS.

Review the SUNSI policy on the NRC internal web page.

Issue Date: 07/01/24 59 1247 App A Review the reference material to gain an understanding of the principles discussed in the evaluation criteria.

Review and discuss the evaluation criteria with your supervisor or fully qualified inspector.

DOCUMENTATION:

Basic-Level Certification Signature Card Item SG-28

Issue Date: 07/01/24 60 1247 App A Basic-Level On-the-Job Training Activities

Issue Date: 07/01/24 61 1247 App A The on-the-job (OJT) activities require you to conduct inspection-related work, under supervision, at a fuel facility. They are designed to allow you to observe and perform key inspection tasks under controlled circumstances. Like the individual study guides, each of the on-the-job activities informs you why the activity is important, how much time you might need to complete the assignment, and what you are expected to complete successfully during the activity.

Prior to beginning the activities in this section, you must successfully complete the course work for site access. There are two ways this can be done. You can complete the NRCs Site Access Course and the site-specific requirements for access. As you visit facilities, you will complete licensee site access training/requirements on-site/on-line. Your supervisor will discuss with you the best way for you to meet the site access requirements.

The following general guidance applies as you complete the various on-the-job activities:

The activities in this section should be completed in the order in which they are presented.

Complete all parts of each activity.

Your supervisor will act as a resource as you complete each activity. Discuss any questions you may have about how a task must be done or how the guidance is applied. Your supervisor may also designate other fully qualified inspectors to work with you as you complete the various activities.

You are responsible for keeping track of what tasks you have completed. Be sure that you have completed all aspects of an OJT activity before you meet with your supervisor for evaluation.

Issue Date: 07/01/24 62 1247 App A (OJT-1) Facility Familiarization Tour with a Qualified Inspector PURPOSE:

The purpose of this activity is to: (1) acquaint you with the general layout of a facility and identify various major pieces of equipment; (2) instruct you in the types of industrial and radiological personal protection requirements and the proper method of complying with these requirements; (3) instruct you in the use of security procedures; and (4) instruct you in the proper response to an emergency if the emergency is declared while in the facility.

In addition, this activity will familiarize you with the appropriate protocol for the conduct of an inspector in the plant and the inspectors role in gathering facility status information. If there is a control room, this activity will also help you to become familiar with general control room layout, required control room staffing, and the inspectors role in gathering facility status information.

COMPETENCY AREA:

INSPECTION COMMUNICATION SELF-MANAGEMENT FUNDAMENTAL PLANT DESIGN AND OPERATION EMERGENCY RESPONSE Note: Completion of this activity may require several facility tours.

LEVEL OF EFFORT:

40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br />

REFERENCES:

Licensees drawing(s) of the site building layouts.

Licensee-specific procedure for the conduct of operations in the control room.

EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of the general plant layout and inspector behavior in the plant by successfully addressing the following:

Given a drawing of the site building layout, be able to identify where the major facility areas are located.

Identify the types of industrial personnel safety equipment that are available and the circumstances under which each piece of equipment should be used.

Explain how you would know what type(s) of radiological protection equipment are required before entering a radiologically controlled area (RCA).

Issue Date: 07/01/24 63 1247 App A Given specific scenarios related to security situations, describe what actions you would take.

Given specific scenarios related to emergency response situations, describe what actions you would take.

Given specific scenarios related to health physics situations, describe what actions you would take.

Explain the appropriate protocol for an inspectors conduct in the plant and control room (if applicable).

Explain how you would respond if you were present in the plant or control room during an emergency situation. Specifically, you should explain why it is never appropriate for an inspector to operate any controls, or to interfere in licensee operations, during routine or emergency situations.

Describe the general layout of a control room (if applicable). Describe examples of site-specific restrictions for limits on where an inspector can go in the plant or a control room, with or without permission.

Describe the basic staffing in the plant and control room (if applicable) and where you would expect to find various operators.

Describe the types of information an inspector gathers in the plant and control room and how that information is obtained.

TASKS:

1. Review a drawing(s) of the building layout for the site and plan a route for a tour that will include the major areas on the site, such as:
a. main production area
b. central alarm systems and secondary alarm systems (CAS & SAS) if applicable
c. RCA
d. emergency response facility
e. control room(s)
f.

liquid waste treatment facilities

g. airborne effluent treatment facilities
h. criticality warning system
i.

other areas deemed appropriate by a qualified inspector or resident inspector, if applicable.

Issue Date: 07/01/24 64 1247 App A

2. Prior to the tour, discuss the requirements for personal industrial safety equipment with a qualified inspector or resident inspector, if applicable.
3. Tour the facility with a qualified inspector or resident inspector, if applicable, and locate the major pieces of equipment and facility areas, including but not limited to those items described above.
4. Enter the RCA with a qualified inspector or resident inspector, if applicable, and tour the area to observe and/or discuss items such as: different radiological control postings, methods of designating areas that have additional radiological control requirements for entry, different radiological control clothing requirements for different areas, use of portal monitors and personal friskers, and personal monitoring dosimetry.
5. During the plant tour, discuss the proper security procedures for entering the areas discussed above, including the actions to take in the event a procedure error or violation of security rules is committed or observed.
6. During the plant tour, discuss the proper response in the event an emergency is declared while in the facility.
7. During the plant tour, discuss the proper response in the event of a radiological control event or anomaly.

DOCUMENTATION:

Basic-level Certification Signature Card OJT-1

Issue Date: 07/01/24 65 1247 App A (OJT-2) Licensee Performance Reviews (LPRs)

PURPOSE:

The purpose of this activity is to: (1) acquaint you with the various types of information discussed in the meetings that develop LPRs; (2) instruct you in the types of information provided in the LPR that are important to an inspector; and (3) inform you of the appropriate inspector protocols so that you will know when NRC participation is and is not appropriate.

COMPETENCY AREA:

INSPECTION COMMUNICATION SELF-MANAGEMENT LEVEL OF EFFORT:

2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />

REFERENCES:

None EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of the NRC inspectors role in the LPR development meeting, by successfully discussing the following:

Identify the types of information discussed in the LPR development meeting that are important to an inspector and discuss why the information is important.

Given specific examples, be able to discuss if it is appropriate for an inspector to participate in the discussion at or about the LPR development meeting.

TASKS:

Discuss with a qualified inspector the types of information provided at the meeting or in a LPR meeting document that would be important to you and why that information is important.

Discuss with a qualified inspector the protocols of when an NRC inspector should and should not participate in the LPR development meeting.

Review the licensees overview organization chart and then either observe an LPR meeting with a licensee/DFFI staff; or review LPR meeting documentation with a qualified inspector.

Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Certification Signature Card Item OJT-2

Issue Date: 07/01/24 66 1247 App A (OJT-3) Inspection Activities PURPOSE:

The purpose of this activity is to familiarize you with inspection tasks commonly performed by an inspector. This OJT will prepare you to independently plan and conduct the baseline inspection program as defined in the applicable IMC.

COMPETENCY AREA:

INSPECTION COMMUNICATION TEAMWORK SELF-MANAGEMENT LEVEL OF EFFORT:

Note: The objective of this activity is to make sure that you have experienced the full range of inspection activities. The time needed to complete the tasks will depend on your individual proficiency. There is no set number of inspections you must complete. You must participate in inspections until such time as you can address the evaluation criteria to the satisfaction of your supervisor.

REFERENCES:

IMC 0330, Guidance for NRC Review of Licensee Draft Documents IMC 2600, Fuel Cycle Facility Operational Safety and Safeguards Inspection Program, or equivalent, for planned inspection Inspection procedure(s) for planned inspection(s)

License application or safety analysis report for activity to be inspected Regional Guidance or Office Guidance (if applicable)

EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of the baseline inspection process by:

Describing the contents and purpose of the site-specific inspection plan.

Describing the purpose of the inspection planning; communications with licensee regulatory staff (emails/phone calls), and full utilization/access of the licensees e-libraries for licensee document access. Most licensees have implemented e-libraries.

Issue Date: 07/01/24 67 1247 App A Providing your supervisor or the person designated as a resource with a specific inspection plan that you have prepared. Describe the purpose and contents of a specific inspection plan.

Discussing the documents to be reviewed including their content and purpose prior to an inspection.

Describing the contents and purpose of the part of the entrance meeting you conducted.

Describing the activities you accomplished during the inspection(s) and their purpose.

Describing the purpose of the management brief and the exit pre-brief of licensee management in which you participated.

Describing the contents and purpose of the part of the exit meeting you conducted.

TASKS:

1. Review the annual or applicable site-specific inspection plan to understand where your inspection effort fits into the plan.
2. Participate in an inspection planning call to the licensee.
3. Participate in developing the inspection specific plan.
4. Review the following documents to understand how they provide background information, current issues, areas for emphasis, and support for the inspection effort you plan to accomplish:
a. Previous inspection reports.
b. Appropriate licensee documents
c. Applicable IPs
d. Other applicable documents, i.e., Licensee Event Reports, Information Notices, Bulletins, etc.
5. Observe an entrance meeting.
6. Observe the activities performed by a qualified inspector during the completion of the planned inspection by:
a. Observing implementation of inspection procedures
b. Observing interviews / discussion with facility personnel
c. Observing facility work activities
d. Reviewing documentation and records
e. Discussing inspection results with the lead inspector

Issue Date: 07/01/24 68 1247 App A

7. Observe briefing of NRC management.
8. Observe an exit pre-brief of licensee management.
9. Observe an exit meeting.
10. Participate as an active member in an inspection by:
a. Drafting a portion of the inspection specific plan.
b. Conducting activities described in item 6 above, as appropriate.
c. As deemed appropriate by your supervisor, conducting a portion of:
i.

The entrance meeting ii.

The briefing of NRC management iii.

The pre-brief of licensee management iv.

The exit meeting

11. Meet with your supervisor or the person designated to be your resource for this activity and discuss the items listed in the Evaluation Criteria section.

DOCUMENTATION:

Basic-Level Qualification Signature Card Item OJT-3

Issue Date: 07/01/24 69 1247 App A (OJT-4) Documenting Inspection Findings PURPOSE:

The purpose of this activity is to give guidance on content, format, and style for inspection reports. The objectives of this activity are to ensure that inspection reports: 1) clearly communicate significant inspection results to licensees, NRC staff, and the public; 2) provide a basis for significance determination and enforcement action; and 3) present information associated with significant inspection findings in a manner that will be useful to NRC management in developing longer term, broad assessments of licensee performance.

COMPETENCY AREA:

FUNDAMENTAL PLANT DESIGN AND OPERATION INSPECTION COMMUNICATION TEAMWORK ASSESSMENT AND ENFORCEMENT LEVEL OF EFFORT:

40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br />

REFERENCES:

IMC 0330, Guidance for NRC Review of Licensee Draft Documents IMC 0616, Fuel Cycle Safety and Safeguards Inspection Reports IMC 0620, Inspection Documents and Records DFFI RPS How to Guide Regional Guidance or Office Guidance (if applicable)

Enforcement Policy (Refer to the NRC internal website)

EVALUATION CRITERIA:

Upon completion of this activity, you will be asked to demonstrate your understanding of documenting inspection findings by successfully addressing the following:

Discuss the thresholds for determining what findings should be documented in an inspection report.

Describe how to process a finding using the NRC Enforcement Policy.

Discuss how to write an inspection report input.

Discuss how to write a violation.

Issue Date: 07/01/24 70 1247 App A Contrast the differences in documenting Inspector-Identified Findings and Licensee-Identified Violations.

TASKS:

Using IMC 0616, determine if an identified issue is above the threshold for documentation.

Using IMC 0616 and other available guidance, draft an inspection report input in the RPS test-environment.

Given a violation of regulatory requirements and the Enforcement Policy and guidance, draft a violation in the RPS test-environment.

Using IMC 0330, IMC 0616 and IMC 0620, describe how to determine the documents that must be included as attachments to an inspection report as an agency record.

DOCUMENTATION:

Basic-Level Certification Signature Card Item OJT-4

Issue Date: 07/01/24 71 1247 App A Basic-Level Signature Cards and Certification Inspector Name:

Employee Initials/ Date Supervisors Signature/Date A. Training Courses H-100, Site Access Training (or licensee site access)

F-201 or F-201S, Fuel Cycle Processes G-104S, Expectations for NRC Inspectors G-105 Conducting Reactor Inspections Ethics Training for New NRC Employees Effective Communications for NRC Inspectors Allegations Process MCA-101DC, Intro to Nuclear Materials Control an Accountability1 MCA-104DB, Introduction to Measurement Programs1 MCA-110, Basics of Nuclear Materials Accountability1 MCA-120, Basics of Nuclear Materials Control1 F-101S, Nuclear Criticality Safety OSHA HAZWOPER or web-based Health & Safety Training Suite2 B. Individual Study Activities SG-1 History and Organization of the Nuclear Regulatory Commission SG-2 Inspector Objectivity, Protocol, and Professional Conduct2 SG-3 Allegations2 SG-4 NRCs Response to an Emergency at a Nuclear Facility SG-5 The Enforcement Process and the Backfit Process SG-6 The Office of Investigations SG-7 Exploring the Fuel Facility Inspection Program SG-8 Incident Inspection Team (IIT) Activities, Augmented Inspection Team (AIT), and Special Inspection Team (SIT)

SG-9 Understanding How the Commission Operates

Issue Date: 07/01/24 72 1247 App A SG-10 Organization and Content of the NRC Inspection Manual SG-11 NRC Interagency Agreements SG-12 Interaction with the Public SG-13 Contacts with the Media SG-14 Freedom of Information Act and the Privacy Act SG-15 Entrance and Exit Meetings SG-16 Documenting Inspection Findings SG-17 Differing Professional Opinions (DPO)

SG-18 Integrated Safety Analysis Overview (not MC&A)

SG-19 Overview of 10 CFR Part 30 SG-20 Overview of 10 CFR Part SG-21 Overview of 10 CFR Part 70 SG-22 Overview of 10 CFR Part 71 SG-23 Overview of 10 CFR Part 73 SG-24 Overview of 10 CFR Part SG-25 Overview of 10 CFR Parts 19 and 20 SG-26 Licensee-Specific Regulatory Documents and Procedures (not MC&A Inspectors)

SG-27 Planning Fuel Facility Inspections SG-28 Information Security C. On-the-Job Training Activities OJT-1 Facility Familiarization Tour with a Qualified Inspector or Resident Inspector OJT-2 Licensee Performance Reviews (LPRs)

OJT-3 Inspection Activities OJT-4 Documenting Inspection Findings 1 Required for MC&A inspectors only 2 Required prior to a site visit or inspection

Issue Date: 07/01/24 73 1247 App A This signature card and certification must be accompanied by the appropriate Form 1, Basic Level Equivalency Justification, if applicable.

Basic Inspector Certification (Name)

Has successfully completed all requirements to be certified as a BASIC INSPECTOR Supervisor Signature________________________ Date:____________

Issue Date: 07/01/24 74 1247 App A Form 1: Basic-Level Equivalency Justification Inspector Name:

Identify equivalent training and experience for which the inspector is to be given credit A. Training Courses F-201 or F-201S Fuel Cycle Processes MCA-101DC, Intro to Nuclear Materials Control an Accountability1 MCA-104DB, Introduction to Measurement Programs1 MCA-110, Basics of Nuclear Materials Accountability1 MCA-120, Basics of Nuclear Materials Control1 Nuclear Criticality Safety Self-Study Course OSHA HAZWOPER or web-based Health & Safety Training Suite2 B. Individual Study Activities SG-1 History and Organization of the Nuclear Regulatory Commission SG-2 Inspector Objectivity, Protocol, and Professional Conduct SG-3 Allegations SG-4 NRCs Response to an Emergency at a Nuclear Facility SG-5 The Enforcement Process and the Backfit Process SG-6 The Office of Investigations SG-7 Exploring the Fuel Facility Inspection Program SG-8 Incident Inspection Team (IIT) Activities, Augmented Inspection Team (AIT), and Special Inspection Team (SIT)

SG-9 Understanding How the Commission Operates SG-10 Organization and Content of the NRC Inspection Manual SG-11 NRC Interagency Agreements SG-12 Interaction with the Public SG-13 Contacts with the Media SG-14 Freedom of Information Act and the Privacy Act

Issue Date: 07/01/24 75 1247 App A Inspector Name:

Identify equivalent training and experience for which the inspector is to be given credit SG-15 Entrance and Exit Meetings SG-16 Documenting Inspection Findings SG-17 Differing Professional Opinions (DPO)

SG-18 Integrated Safety Analysis Overview (not for MC&A Inspectors)

SG-19 Overview of 10 CFR Part 30 SG-20 Overview of 10 CFR Part 40 SG-21 Overview of 10 CFR Part SG-22 Overview of 10 CFR Part SG-23 Overview of 10 CFR Part SG-24 Overview of 10 CFR Part SG-25 Overview of 10 CFR Parts 19 and SG-26 Licensee-specific regulatory documents and procedures (not for MC&A Inspectors SG-27 Planning Fuel Facility Inspections SG-28 Information Security C. On-the-Job Training Activities OJT-1 Facility Familiarization Tour with a Qualified Inspector or Resident Inspector OJT-2 Licensee Performance Reviews (LPRs)

OJT-3 Inspection Activities OJT-4 Documenting Inspection Findings 1 Required for MC&A inspectors only 2 Required prior to a site visit or inspection accompaniment Supervisors Recommendation Signature / Date____________________________

Division Directors Approval Signature / Date____________________________

Issue Date: 07/01/24 Att1-1 1247 App A : Revision History for IMC 1247 Appendix A Commitment Tracking Number Accession Number Issue Date Change Notice Description of Change Description of Training Required and Completion Date Comment Resolution and Closed Feedback Form Accession Number (Pre-Decisional, Non-Public Information)

N/A 02/18/09 CN 09-006 Researched commitments for 4 years and found none.

New inspection manual chapter to specify qualification requirements for NRC fuel facility operations, health physics, emergency preparedness, security, material control and accounting, and construction inspectors.

N/A ML090400374 ML12257A122 06/27/14 CN 14-014 This Appendix has been revised to reflect the Nuclear Criticality trainings requirements, to update study guides and On the Job training activities, and to incorporate OSHA HAZWOPER or Web-based Health

& Safety Training Suite for required training.

N/A ML14084A477 N/A ML24080A338 07/01/24 CN 24-018 Revised to update training courses, references, evaluation criteria, and tasks for many SGs and OJTs.

Updated for current IMC formatting requirements.

N/A N/A