NuScale Final Safety Analysis Report Mechanical Systems and Components NuScale US460 SDAA 3.9-79 Draft Revision 2 Table 3.9-16: Active Valve List Valve No.

Description ASME Class Function1 ASME Class 1, 2, and 3 Chemical and Volume Control System CVC-AOV-0336 CVCS Discharge Isolation Valve 3

5 CVC-SV-0404 RPV High Point Degasification Isolation Valve 3

5 CVC-AOV-0089 Demineralized Water Supply to CVC Makeup Upstream Isolation Valve 3

3 CVC-AOV-0090 Demineralized Water Supply to CVC Makeup Downstream Isolation Valve 3

3 Containment System CVC-CKV-0323 Pressurizer Spray Check Valve 3

65 CVC-CKV-0329 CVCS Injection Check Valve 3

65 CVC-HOV-0324 Pressurizer Spray Outboard Containment Isolation Valve 1

1, 2, 3, 4 CVC-HOV-0325 Pressurizer Spray Inboard Containment Isolation Valve 1

1, 2, 3, 4 CVC-HOV-0330 CVCS Injection Outboard Containment Isolation Valve 1

1, 2, 3, 4 CVC-HOV-0331 CVCS Injection Inboard Containment Isolation Valve 1

1, 2, 3, 4 CVC-HOV-0334 CVCS Discharge Inboard Containment Isolation Valve 1

1, 2, 3, 4 CVC-HOV-0335 CVCS Discharge Outboard Containment Isolation Valve 1

1, 2, 3, 4 CVC-HOV-0401 RPV High Point Degasification Inboard Containment Isolation Valve 1

1, 2, 3, 4 CVC-HOV-0402 RPV High Point Degasification Outboard Containment Isolation Valve 1

1, 2, 3, 4 CE-HOV-0001 Containment Evacuation Inboard Containment Isolation Valve 2

2, 3, 4 CE-HOV-0002 Containment Evacuation Outboard Containment Isolation Valve 2

2, 3, 4 CFD-HOV-0021 Containment Flooding & Drain Outboard Containment Isolation Valve 2

2, 3, 4 CFD-HOV-0022 Containment Flooding & Drain Inboard Containment Isolation Valve 2

2, 3, 4 RCCW-HOV-0184 Reactor Component Cooling Water Inlet Outboard Containment Isolation Valve 2

2, 3, 4 RCCW-HOV-0185 Reactor Component Cooling Water Inlet Inboard Containment Isolation Valve 2

2, 3, 4 RCCW-HOV-0190 Reactor Component Cooling Water Outlet Inboard Containment Isolation Valve 2

2, 3, 4 RCCW-HOV-0191 Reactor Component Cooling Water Outlet Outboard Containment Isolation Valve 2

2, 3, 4 FW-HOV-0137 Feedwater Isolation Valve 2

2, 3, 4 FW-HOV-0237 Feedwater Isolation Valve 2

2, 3, 4 FW-CKV-0136 Feedwater Isolation Check Valve 2

3 FW-CKV-0236 Feedwater Isolation Check Valve 2

3 MS-HOV-0101 Main Steam Isolation Valve 2

2, 3, 4 MS-HOV-0201 Main Steam Isolation Valve 2

2, 3, 4 MS-HOV-0103 Main Steam Isolation Bypass Valve 2

2, 3, 4 MS-HOV-0203 Main Steam Isolation Bypass Valve 2

2, 3, 4 Decay Heat Removal System DHR-HOV-0111 Decay Heat Removal System Actuation Valve 2

3, 4 DHR-HOV-0121 Decay Heat Removal System Actuation Valve 2

3, 4 DHR-HOV-0211 Decay Heat Removal System Actuation Valve 2

3, 4 DHR-HOV-0221 Decay Heat Removal System Actuation Valve 2

3, 4

NuScale Final Safety Analysis Report Mechanical Systems and Components NuScale US460 SDAA 3.9-80 Draft Revision 2 Emergency Core Cooling System2 ECC-POV-0001A Reactor Vent Valve A 1

1, 3, 4 ECC-POV-0001B Reactor Vent Valve B 1

1, 3, 4 ECC-POV-0002A Reactor Recirculation Valve A 1

1, 3, 4 ECC-POV-0002B Reactor Recirculation Valve B 1

1, 3, 4 Safety and Relief Valves RCS-PSV-0003A Reactor Safety Valve A 1

1, 3 RCS-PSV-0003B Reactor Safety Valve B 1

1, 3 SGS-RV-0102 Steam Generator System Thermal Relief Valve 2

2 SGS-RV-0202 Steam Generator System Thermal Relief Valve 2

2 Non-Code Class Valves Condensate and Feedwater System FW-AOV-0134 Feedwater Regulating Valve NC 67 FW-AOV-0234 Feedwater Regulating Valve NC 67 FW-CKV-0135 Backup Feedwater Check Valve NC 67 FW-CKV-0235 Backup Feedwater Check Valve NC 67 Main Steam System MS-AOV-0102 Backup Main Steam Isolation Valve NC 67 MS-AOV-0202 Backup Main Steam Isolation Valve NC 67 MS-AOV-0104 Backup Main Steam Isolation Bypass Valve NC 67 MS-AOV-0204 Backup Main Steam Isolation Bypass Valve NC 67 1 - Function 1 - Reactor coolant pressure boundary 2 - Containment isolation 3 - Accident mitigation 4 - Safe shutdown 5 - Nonsafety-related, but provide an augmented quality function (NRC Quality Group C/D boundary) 6 - Nonsafety-related, but provide an augmented quality function (NRC Quality Group C/D boundary, backup containment isolation) 67 - Nonsafety backup to a safety-related function (Section 15.0.0.6.6) 2 - Trip and reset valves are included with each RVV and RRV.

Table 3.9-16: Active Valve List (Continued)

Valve No.

Description ASME Class Function1

NuScale Final Safety Analysis Report Mechanical Systems and Components NuScale US460 SDAA 3.9-94 Draft Revision 2 Notes:

2.

Valves with augmented test requirements have a beyond-design-basis event function and a Regulatory Guide 1.26, footnote 5, class break function (valves of high leaktight integrity).are relied on in the safety analyses, and these components either provide a nonsafety backup to a safety-related function or are nonsafety-related that provide an augmented quality function. The design does not use safety-related electric power to mitigate accidents or for the safe shutdown of the NPM; therefore, all valves listed have an active-to-failed function to transfer to its backup position on loss of motive power. Valves with an active function are tested by observing the operation of the actuator upon loss of valve actuating power.

3.

Cold Shutdown Outage as defined in ASME OM Code, Paragraph ISTA-2000 is Mode 3, safe shutdown, with all reactor coolant temperatures < 200 degrees F.

The term cold shutdown is used throughout Section 3.9.6 for clarity with the OM Code requirements (Section 3.9.6.4.1).

4.

Backup CVCS Check Valves: The backup CVCS check valves are normally closed, nozzle check valves. These valves cannot be full-stroke or part-stroke exercised closed during plant operation because system flow must be reversed to demonstrate valve closure. The nozzle check design is a spring-to-close design. Nonintrusive testing can be used to verify valve closure (safety-function position) at cold shutdown. Normal CVCS operation satisfies the open (nonsafety-function position) exercise for these valves pursuant to ISTC-3550, Valves in Regular Use, at a frequency that satisfies the requirements for augmented testing by periodically measuring line flow and pressure to confirm the valves are fully open.

Table 3.9-18: Valve Augmented Requirements Valve No.

Description Valve /

Actuator1 Function Position Augmented Function(s)2 ASME Class / IST Category IST Type3 Notes Chemical Volume and Control System CVC-AOV-0336 CVCS Discharge Isolation Valve BALL Remote AO Closed Active BDBE Containment Isolation Class 3 Category A Position Verification Test Exercise Full Stroke/QuarterlyCold Shutdown Failsafe Test/QuarterlyCold Shutdown Leak Test Performance Assessment Test N/A5 CVC-SV-0404 NDS Supply to Reactor Module IsolationRPV High Point Degasification Solenoid Valve GLOBE Remote SO Closed Active BDBE Containment Isolation Class 3 Category A Position Verification Test Exercise Full Stroke/QuarterlyCold Shutdown Failsafe Test/QuarterlyCold Shutdown Leak Test N/A5 CVC-CKV-0329 CVCS Injection Check Valve Nozzle Check Closed Active BDBE Containment Isolation Class 3 Category A/C Check Exercise/Cold Shutdown Leak Test 44, 5 CVC-CKV-0323 Pressurizer Spray Check Valves Nozzle Check Closed Active BDBE Containment Isolation Class 3 Category A/C Check Exercise/Cold Shutdown Leak Test 44, 5 1.

AO air operated CVCS chemical volume and control NPM NuScale Power Module RPV reactor pressure vessel

NuScale Final Safety Analysis Report Mechanical Systems and Components NuScale US460 SDAA 3.9-95 Draft Revision 2 5.

Backup Containment Isolation Valves: Third isolation valves that provide a nonsafety backup function as defined by Regulatory Guide 1.26, C.2(c) footnote 6 as having high leaktight integrity. These valves define the NRC Quality Group C/D and Seismic I/III classification break. The power operated valves receive a nonsafety containment isolation signal.

NuScale Final Safety Analysis Report Environmental Qualification of Mechanical and Electrical Equipment NuScale US460 SDAA 3.11-13 Draft Revision 2 I&C Separation Group A Electrical Penetration Assembly (EPA)

CNV-5, RXBP-1 Harsh Electrical Mechanical A

B,C,D 720 I&C Separation Group B Electrical Penetration Assembly (EPA)

CNV-5, RXBP-1 Harsh Electrical Mechanical A

B,C,D 720 I&C Separation Group C Electrical Penetration Assembly (EPA)

CNV-5, RXBP-1 Harsh Electrical Mechanical A

B,C,D 720 I&C Separation Group D Electrical Penetration Assembly (EPA)

CNV-5, RXBP-1 Harsh Electrical Mechanical A

B,C,D 720 CRDM Power 2 Nozzle Electrical Penetration Assembly (EPA)

CNV-5, RXBP-1 Harsh Electrical Mechanical A

N/A 720 Main Steam Isolation Valve (MSIV) #1 and #2 RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 MS Isolation Bypass Valve (MSIBV) #1 and #2 RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 Feedwater Isolation Valve (FWIV) #1 and #2 RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 Feedwater Isolation Check Valve #1 and #2 RXBP-1 Harsh Mechanical A

B N/A 1

720 RCCW Supply CIV, Inboard and Outboard RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 RCCW Return CIV, Inboard and Outboard RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 RPV High Point Degas CIV, Inboard and Outboard RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 RPV High Point Degas Solenoid Valve RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 PZR Spray Flow Check Valve RXBP-1 Harsh Mechanical A

B N/A 1

720 Table 3.11-1: List of Environmentally Qualified Equipment Located in Harsh Environments (Continued)

Description(4)(5)

Environmental Qualification Zone(1)

Environmental Qualification Environment Qualification Program Environmental Qualification Category(3)

PAM Type(2)

Operating Time (Hrs)

NuScale Final Safety Analysis Report Environmental Qualification of Mechanical and Electrical Equipment NuScale US460 SDAA 3.11-14 Draft Revision 2 PZR Spray CIV, Inboard and Outboard RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 CVC Injection Flow Check Valve RXBP-Harsh Mechanical A

B N/A 1

720 CVC Injection CIV, Inboard and Outboard RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 CVC Discharge CIV, Inboard and Outboard RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 CVC Discharge Air Operated Valve RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 Containment Flood and Drain CIV, Inboard and Outboard RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 Containment Evacuation CIV, Inboard and Outboard RXBP-1 Harsh Electrical Mechanical A

B N/A 1

720 Central Hydraulic Power Unit Skid A and Skid B RXBG-8 Harsh Electrical Mechanical A

B N/A 1

720 Passive Autocatalytic Recombiner (PAR)

CNV-4 or CNV-5 Harsh Mechanical B

N/A 720 Containment Narrow Range Pressure Element A/B/C/D CNV-6 Harsh Electrical A

N/A 720 Containment Wide Range Pressure Element A/B CNV-Harsh Electrical A

B,C,D 720 Containment Level Indication A/B/C/D RXBP-1, CNV CNV-6 Harsh Electrical A

N/A 720 SG #1 and SG #2 Main Steam Temperature Indication A/B/C/D RXBP-1 Harsh Electrical A

N/A 720 FWIV #1 Position Indication A / B RXBP-1 Harsh Electrical A

B,C,D 720 FWIV #2 Position Indication A / B RXBP-1 Harsh Electrical A

B,C,D 720 Table 3.11-1: List of Environmentally Qualified Equipment Located in Harsh Environments (Continued)

Description(4)(5)

Environmental Qualification Zone(1)

Environmental Qualification Environment Qualification Program Environmental Qualification Category(3)

PAM Type(2)

Operating Time (Hrs)

NuScale Final Safety Analysis Report Containment Systems NuScale US460 SDAA 6.2-68 Draft Revision 2 Table 6.2-7: Classification of Structures, Systems, and Components SSC (Note 1)

Location SSC Classification (A1, A2, B1, B2)

Augmented Design Requirements (Note 2)

Quality Group/Safety Classification (Ref RG 1.26 or RG 1.143)

(Note 3)

Seismic Classification (Ref. RG 1.29 or RG 1.143)

(Note 4)

CNTS, Containment System All components (except as listed below)-

RXB A1 None B

I

  • CIVs (CVC PZR spray, RPV high point degasification, CVC injection & discharge)
  • CITFs (CVC PZR spray, RVP high point degasification, CVC injection & discharge)

RXB A1 None A

I

  • CIV stored energy device pressure transmitters (MSIV, FWIV, RCCW CIVs, CVC high point degasification CIVs, PZR spray CIVs, CVC injection & discharge CIVs, CFD CIVs, CE CIVS)
  • Containment pressure instrumentation (narrow range)
  • Containment level instrumentation
  • MS temperature sensors
  • Closed and open position indicators for FWIVs
  • Supply/vent hydraulic lines from CHPU to CIVs

Feedwater isolation check valves RXB A2 None B

I

  • CNV-RPV support ledge
  • CNV CRDM support frame
  • Supply/vent hydraulic lines from CHPU to DHRS actuation valves RXB A2 None N/A I
  • CVC discharge air operated valve
  • Piping from PZR spray CIVs to class 3 CVC PRZ spray check valve (outside CNV)
  • Piping from CVC injection CIVs to class 3 CVC injection check valve (outside CNV)
  • Piping from CVC discharge CIVs to class 3 CVC discharge isolation valve (outside CNV)
  • Piping from CVC RPV high point degasification CIVs to class 3 RPV high point degasification isolation valve (outside CNV)

RXB B2B1

  • Subject to in-service testing (Note 2)

C III

NuScale Final Safety Analysis Report Containment Systems NuScale US460 SDAA 6.2-69 Draft Revision 2

  • Piping from PZR spray CIVs to class 3 CVC PZR spray check valve (outside CNV)
  • Piping from CVC injection CIVs to class 3 CVC injection check valve (outside CNV)
  • Piping from CVC discharge CIVs to class 3 CVC discharge isolation valve (outside CNV)
  • Piping from CVC RPV high point degasification CIVs to class 3 RPV high point degasification isolation valve (outside CNV)

RXB B2 None C

II

RXB B2 None D

I

  • Piping from (CFDS and RCCWS) CIVs to disconnect flange (outside CNV)
  • Piping from class 3 CVC valves to disconnect flange (outside CNV)
  • CFD piping (inside CNV)
  • CNV test line A and B RXB B2 None D

II

  • Containment top support structure
  • Feedwater temperature sensors RXB B2 None N/A I
  • Containment pressure instrumentation (wide range)

RXB B2 IEEE 497-2016 (Note 5)

N/A I

PAR RXB B2 RG 1.7 N/A II

  • Closed and open position indicators (RPV high point degasification solenoid valve, CVC discharge AOV)
  • Flushing hydraulic line from CHPU to inboard &

outboard CIVs and DHR actuation valves RXB B2 None N/A II Table 6.2-7: Classification of Structures, Systems, and Components (Continued)

SSC (Note 1)

Location SSC Classification (A1, A2, B1, B2)

Augmented Design Requirements (Note 2)

Quality Group/Safety Classification (Ref RG 1.26 or RG 1.143)

(Note 3)

Seismic Classification (Ref. RG 1.29 or RG 1.143)

(Note 4)

NuScale Final Safety Analysis Report Reliability Assurance Program NuScale US460 SDAA 17.4-9 Draft Revision 2 CNTS (Continued)

  • CVCS piping (outside containment):

- RPV high point degasification solenoid valve to disconnect flange

- PZR spray flow check valve to disconnect flange

- Injection flow check valve to disconnect flange

- Discharge air operated valve to disconnect flange

  • Containment pressure transducers (wide range)
  • CNTS top support structure
  • Containment vessel, control rod drive mechanism support frame
  • RPV support ledge
  • Passive autocatalytic recombiner
  • Provides backup isolation capability for containment isolation lines that may result in a loss-of-coolant event.

B1

  • CVCS discharge air operated valve
  • CVCS piping: (outside containment)

- RPV high point degasification CIV to reducer

- Reducer to RPV high point degasification solenoid valve

- PZR spray CIV to PZR spray flow check valve

- Injection CIV to injection flow check valve

- Discharge CIV to discharge air operated valve Determination by expert panel and informed with input from PRA, deterministic, and other methods of analysis Reactor Core System (RXC)

  • Contains fission products and transuranics within the fuel rods to minimize contamination of the reactor coolant
  • Maintains a coolable geometry under normal operating and design-basis event conditions A1
  • Fuel assembly Determination by expert panel and informed with input from PRA, deterministic, and other methods of analysis Table 17.4-1: Design Reliability Assurance Program Structures, Systems, and Components Functions, Categorization, and Categorization Basis (Continued)

System Function Function Category (A1 & B1)

SSC Required to Perform System Function Basis for Function Categorization

License Conditions; ITAAC Module-Specific Structures, Systems, and Components Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Design Descriptions and ITAAC NuScale US460 SDAA 49 Draft Revision 2 RCCW-HOV-0190 RCCWS return inboard CIV Harsh Electrical Mechanical Yes Yes A B RCCW-HOV-0191 RCCWS return outboard CIV Harsh Electrical Mechanical Yes Yes A B CE-HOV-0001 CES inboard CIV Harsh Electrical Mechanical Yes Yes A B CE-HOV-0002 CES outboard CIV Harsh Electrical Mechanical Yes Yes A B CFD-HOV-0022 CFDS inboard CIV Harsh Electrical Mechanical Yes Yes A B CFD-HOV-0021 CFDS outboard CIV Harsh Electrical Mechanical Yes Yes A B CVC-CKV-0323 PZR spray flow check valve Harsh Mechanical Yes N/A A B CVC-CKV-0329 CVCS injection flow check valve Harsh Mechanical Yes N/A A B CVC-AOV-0336 CVC discharge air operated valve Harsh Mechanical Yes No A B CVC-SV-0404 RPV high point degas solenoid valve Harsh Electrical Yes No A B CNT-SKD-0500 CNT-SKD-0600 Central hydraulic power unit skids Harsh Electrical Mechanical Yes Yes B

CNT-PE-1001A CNT-PE-1001B CNT-PE-1001C CNT-PE-1001D Containment narrow range pressure elements Harsh Electrical Yes Yes A

CNT-PE-1002A CNT-PE-1002B Containment wide range pressure elements Harsh Electrical Yes No A

CNT-LE-1003A CNT-LE-1003B CNT-LE-1003C CNT-LE-1003D Containment level indication Harsh Electrical Yes Yes A

MS-TE-1001A MS-TE-1001B MS-TE-1001C MS-TE-1001D SG #1 main steam temperature indication Harsh Electrical Yes Yes A

MS-TE-2001A MS-TE-2001B MS-TE-2001C MS-TE-2001D SG #2 main steam temperature indication Harsh Electrical Yes Yes A

Table 2.4-3: Module-Specific Mechanical and Electrical/Instrumentation and Controls Equipment (Continued)

Equipment Identifier Description EQ Environment Qualification Program Seismic Category I Class 1E EQ Category(1)