NRC-23-0061, Clarification for NRC-23-0059, Response to Request for Additional Information for Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water..

From kanterella
(Redirected from ML23242A189)
Jump to navigation Jump to search

Clarification for NRC-23-0059, Response to Request for Additional Information for Exigent License Amendment Request for Technical Specification 3.7.2, Emergency Equipment Cooling Water (Eecw)/Emergency Equipment Service Water..
ML23242A189
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 08/30/2023
From: Frank E
DTE Electric Company
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
NRC-23-0061
Download: ML23242A189 (1)


Text

August 30, 2023 NRC-23-0061 DTE Electric Company 6400 N. Dixie Highway Newport, MI 48166 DTE 10 CFR 50.90 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 Fermi 2 Power Plant NRC Docket No. 50-341 NRC License No. NPF-43

Subject:

Clarification for NRC-23-0059, Response to Request for Additional Information for Exigent License Amendment Request for Technical Specification 3.7.2, "Emergency Equipment Cooling Water (EECW)/Emergency Equipment Service Water (EESW) System and Ultimate Heat Sink (UHS)."

References:

1) DTE Letter NRC-23-0050, "Exigent License Amendment Request for Technical Specification 3.7.2, 'Emergency Equipment Cooling Water (EECW)/Emergency Equipment Service Water (EESW) System and Ultimate Heat Sink (UHS)'," dated August 10, 2023 (ML23222A037)
2) NRC E-mail Capture, "Request For Additional Information Changes to TS 3.7.2, 'Emergency Equipment Cooling Water (EECW)/ Emergency Equipment Service Water (EESW) System And Ultimate Heat Sink (UHS)'." Dated August 22, 2023 (EPID L-2023-LLA-0112)

(ML23235A182)

3) NRC E-mail Capture, "Request For Additional Information Changes to TS 3.7.2, 'Emergency Equipment Cooling Water (EECW)/ Emergency Equipment Service Water (EESW) System And Ultimate Heat Sink (UHS)'." Dated August 24, 2023 (EPID L-2023-LLA-0112)
4) DTE Letter NRC-23-0059, "Response to Request for Additional Information Exigent License Amendment Request for Technical Specification 3.7.2,'Emergency Equipment Cooling Water (EECW)/Emergency Equipment Service Water (EESW) System and Ultimate Heat Sink (UHS)'," dated August 25, 2023. (ML23237B419)

In Reference 1, DTE Electric Company (DTE) submitted an exigent License Amendment Request (LAR) to revise the Fermi 2 Technical Specifications (TS). In the Reference 2, an email from Mr. Surinder Arora to Mr. Eric Frank dated August 22, 2023, the NRC sent DTE a Request for Additional Information (RAJ) regarding the LAR. In Reference 3, an email from Mr.

Surinder Arora to Mr. Eric Frank dated August 24, 2023, the NRC sent DTE an

USNRC NRC-23-0061 Page2 additional RAJ regarding the LAR. In Reference 4, DTE provided a response to the NRC RAis.

The purpose of this correspondence is to respond to a phone call from Mr. Surinder Arora to Mr.

Eric Frank dated August 28, 2023, to clarify DTE's response to RAI's APLB 6 and EMIB 7.

In DTE's response to APLB 6, it was stated that Element 3: "Define Implementation and Monitoring Program" was not applicable to the LAR. DTE would like to clarify that the performance of the Mechanical Draft Cooling Tower (MDCT) fans, the Emergency Equipment Cooling Water (EECW), and Emergency Equipment Service Water (EESW) systems are monitored in accordance with the Fermi 2 Maintenance Rule Program.

In DTE's response to EMIB 7, DTE stated that surveillances and testing were addressed in NRC-23-0050, Enclosure 4 Section 6. The correct reference for surveillances and testing should be NRC-23-0050 Enclosure 4 Section 5.

In addition, in response to a phone conversation on 8/29/23, DTE acknowledges the new proposed NRC approval date for the exigent LAR is changed to September 18, 2023. This additional time allows for the 14-day public comment period between September 1, 2023 and September 15, 2023.

No new commitments are being made in this submittal.

Should you have any questions or require additional information, please contact me at (734) 586-4772.

cc: NRC Project Manager NRC Resident Office Regional Administrator, Region III Sincerely,

[(;J1vvl Eric Frank Manager - Nuclear Licensing