ML23129A453
| ML23129A453 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 04/20/2023 |
| From: | Nebraska Public Power District (NPPD) |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML23129A261 | List:
|
| References | |
| NLS2023022 | |
| Download: ML23129A453 (1) | |
Text
V>
z 0 !
0 z 135" X-206 A X-206 B X-203 B X-221
~
X-203 A 112'30' X-212 X-218 X-22 90" ----
X-210 A X-229 D 67'30' c,I'
- I
, I
<o X-224~
0 I ;,,
X-211 A X-229 C
- 'i' 1,,
5'-0" X-225 B 180' 157'30' X-223 A X-223 B 202'30' X-229 F X-229 E
\
X-209 A X-209 B X-215 0.}:)
r§*~~"':,
..,,,,,.o X-220 BAY 6 BAY 5 BAY 7 X-300 E X-201 C X-207 C
\
BAY 9 X-300 H X-300 G X-201 D X-202 E X-202 F X-207 D X-208 C & D
!z"'
WI m~
/
/............/
X-201 E X-202 G X-202 H X-207 E X-208 E &: F I
BAY 11 X-300 J
,/
/
/
/
X-201 F X-202J X-202K X-207F X-229 H
/
X-300 L BAY 13 R BENT _____
______ ~ BENT
,:. F-7
'I:. F-3 X-300 D
//............
/
X-300 C X-201 B X-202 C X-202 D X-207 B
/
/
/
)f,:
//
X-300 B BAY 3 X-300 A X-201 A X-202 A X-202 8 X-207 A X-208 A & B
,_ z-WI m~
X-201 H X-202 L X-202 M X-207 H X-208 G & H X-300 0 X-300 P BAY 1 BAY 16 x-:mo M---1--,.
X-300 N-~
-i-BAY 15
.)
.,~
'--------------------------~7 X-206C X-206D
./
225' X-209 D X-200 B
~
~X-2138 X-219 I
0 I 5'-0" X-211 X-229 J 247'30' X-229 K B
X-210 8 X-205
~292'30' X-226 X-225 C INSCDE DRYWELL 270' JET DEFLECTOR SCH. 80 PIPE X-5 (SEE 0RAWJNG#4259)
EXPANSION BELLOWS X-201 A THRU X-201 H (ROTATED INTO SECTION)
X-208 A THRU H X-216 &
\
X-217 X-220 &
X-205 FOR CONTINUATION -~J:::::::::::::::=-------tr1 SEE EDS DRAWINGS VR-P WW1 THRU 3
__,,_E_L_B_7_6' -:2_ 1~/_2_" - -+--
~
0 1,,
NOTE:
/
X-.300 A-P TYPICAL ARCS GIVEN ON OUTS.
SHELL TO q_ PENT.
"' FOR DETAIL OF 1.
DRAIN LINE SEE KAISER DWG. S-1005
~ELBB0'-11"
/
/
/
X-213A&B 9'-7 1/2" ARC=10'-6 13/32" 5'-0" ARC=
X-211 A & B
\
s*-, 9/32" So-
/4-202
/
A THRU /
/
X-207 A THRU H"'
\
COMPOSITION SECTION
\
X-230
/
X-210 A & B, X-228 X-218, X-219
--.....__ X-206 A & C, X-209 A THRU D
~c-1.
X-20.3 A & B, X-215
°" -:=
'1 X-221 & X-222 X-229 L & M i X-206 B & D X-224, X-225A THRU D X-226, X227 A & B
~ ~
X-212, X-214, X-22.3 A & B X-229 A THRU H & J THRU K X-225A1/
X-216 X-217
~-225D ROTATE COUNTER CLOCKWISE
/
,\'\,
,/1 I
s*-sn 6'-5" 45' 6"
X-200 A X-229 B X-229 A 22'30' o*
PLAN VIEW SUPPRESSION X-214 CHAMBER X-229 L X-229 M 337'30'
~
315' X-222 NOTES:
REVISIONS BY N.P.P.D.
NO.
REVISIONS DFT CKD APP DATE NOO CR96-0160 DCN 97-0097 SPB JEH JRF 1-31-9
- 1. ALL PENETRATIONS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS. LOCATIONS WERE TAKEN FROM BURNS AND ROE DRAWING 4260 SHT. 2 AND CHICAGO BRIDGE AND IRON COMPANY DRAWING # 5.
- THIS DRAWING GENERATED BY NPPD SIGNIFICANT NUIIIBER GROUP 4
CONTAINMENT SUPPRESSION CHAMBER PENETRATION SHEET LOCATION 2A DRAWN SPB CHEa<ED JEH APPROVED JRF FILMED DATE 3/22/96 DATE 1/31/97 DATE 1/31/97 454243227 AS BUILT CADD DRAWING DO NOT REVISE MANUALLY BURNS & ROE*
N -
0 0
~u C
REVISION 4260 NOO 0
~