Text
{{#Wiki_filter:r-----t. To DRYWl:LL .---l. IE'-IC...O!!IU~l!i IS 85 78 88 81 80 ti.ii:,_ 3-'e)- - - 92 87 86 95 ~ l"SSBO 17 PCV r1/2 ss. eo i'o !1111' f!T, "'*3it I ~ - -1 rn r., 71 '. 74 73 -- _J E F 11R11 1S "" CRP-3+ r r r -- -- -* - 1 I I. J...., ' ' I 13/z" 5 5. Bo 43A 3c/8A 50 48 47 44A 4G 40 TO ,,~-L1 ".ai.S,ai_S,:!!80~ -~-1 SEE NOTE 6 CONOENSAT"I TA~k 57A VV-f 6 8 B { ,-4*,s"" ry.*ss 1'j<J 42B 63 FILTER 3-17 8 7 T 61 44B CO-/'fUACT J: f1*11 PlOM 0~1\l'J: W'A'l"IIII: PUl'1JI" TO £QUIP' DAAI N 5EE NPPti-CNS*CRl' -13 AS A? 1/'2" HIGH PRESSURe. FLEXle>L.E H~ At IOIA I " '---------------------------7 0.. 1-- Ill PENETR,1T1011n
- t:*Z7A (FRoM-f-,,J.--'ltl r1 pe-if.i-TION X*
c (FQ.011\~'2) i:>!!!Nl!I.Tl'll>.TION X*37C. y I;: I-- L ,,a 111 STN. 5 TEEL CLJU,, tN/15 PIP~ 4 2>>'1 OTl-1 lil'lS --,----C><]- - -- - 155& _,;1"-- SCRAM DISCHARGE VOLUMES 1/1.,.
- 3* PE NETR,o.TION 2 87 26'8 CRD-CV-28CV CRD-V-300 CRD-V-301 CRD-CV-32CV 3/4" 1"x 3/4* RED~.--...__
(lYP.) (SOUTH) (66) BLOCI< ROD 1WITHDRAWL
- 96)
(70) 3/4"- ~ 3/4' ORAi N-- (97) (68) B'l-lY-3 .(69) SLOPE1/4 :1~ .~r:==:;::'c:'9*9<:) 1-L.-r9'f3t~~, (67 l~HY-3 SLOPE 1/4'; 1 FT. 3/4" DRAIN (95) (65) (NORTH) BELLOWS SENSOR FOR SEALED CAPILLARY CONNECTION TO LEVEL TRANSMITTER (TYP. 8) (209) 211) 8"HY-J (207 212) (208 ~~,3/4,, (214) (216) 3/4" DRAIN 210) 1"HY-J 8" (205) BLOCK ROD WITHDRAWL-,
- 1.
3/4"RAIN (206) 202 1" SLOPE1/4":1FT. CRD-CV-29C CRD-V-303 CRD-V-302 CRD-CV-33C 1/a"SS. 80 TYP RD-V-320 CRD-V-321 J N CRD-V-323 CRD-V-322 1-, HE CP..?01 s,.,-r. z. 3-JIS ,CL.HS llill'/1!$ Pll>ir. 3* /01 tl4 3-137 j _J-* ~ 118 ,-102 3°101 7 II II ,,o 1 C:I. H FN/ I' PIN 1-- () m 3/4" SS 80 (TYP.) 280 2797::......J 281 282 CRD-RV-22RV CRD-PRV-33 B"HY-3 u CRD-V-312 CRD-CV-40CV IIN IS IN IS CV32A IIN IS IN IS en CV35 =~ u CV33 (218) CRD-V-328 CONT. ON B&:R DWG.2028 ZONE F-5 CRD-~3DCV CRD-V-317 CRD-V-316 CRD-~34CV CRD-V-325 CRD-V-324 N ~ --h-i~---'rAJ!J: ~ --h-iffi-+---'rAJ!J: C 1/2" INST. AIR NO re (217) CV34 CV36 en CRD-V-329 ~ :::: u z~ CONT. ON B&R DWG.2028 ZONE E-1 C D-QY'.=31C RD-V-318 CRD-V-319 CRD-~35CV CRD-V-326 CRD-V-327 21CVU 19CV 20CVU2CV <b8B R OPEN TO ATMOSPHERE FROM OTHER HYDRAULIC CONTROL ROD UNITS FOR T Q CONNECTIONS TO A s CRD-RV-23RV CRD-PRV-34 CRD-V-313 CRD-CV-41 CV CRD-V-333 I, IIN IS NO IN/IS re
- CV32B,
.... B"HY-3 IIN IS IN/IS 276 I 275 u 277 I 278 ~------------------GIVEN SCRAM VOLUME ------------------~ 3* 140A - la ~~ 1-...--1'.. -----D 141 HOR., SEE CONTRACTOR FLOW DIAGRAM CP-001 SH.2 CRD-V-299 3-.31 B 3-31A CRD-CV-27CV CLll5:S J7 D
- -f Pl Pf
,uo,11 Alt n H,O N, 3*125 L!.I {SOUT!t-HEA.DEiS) r&Z8 1151A ,--~,8"7 ""'._...,.. """'-"'- 'i:°-"1' ~. :,..o*.. '~---~.....,_l_--1 ,n IIS Y, *s.s (rrP_) ?..,~ f--lf-- '------+-O,Q--+-,1t--~~,-.!.!C.....:;,<.'-;.,,.:.--' "1C I 61C> HrDA~ 1JL.IC co.iTROL 3-13 UNIT TYP. 117 1/2"' s, * &o 1/*" S S. &o 11\0RTH HEAPE.I(~ 125 A* IS TO !;OSI: 'STA. TIOM I,,.-.._ ~ I--DIA-P;-41-i!:t:..M OP'E~Al ~o 'N IT'K MA.N.U~L,, c:::Nl:ClalDI ~ C""'!:.Q,£ Vt:,...L'-1& W\\\\~ Q-.rll='ICi, ---{><}-.si.e,_ "'[ I": '-'"-1.V i: -w-GLOE!>~ VA.Lve ---{:::94- $'TOP CHECO:: Y"LV&
f'.._J-C I-' !; C "'- Vl>.L V \;
~- NE.cDLE: VAL.Vt; ........ e,A\.\., \/AL.VE. -AA-l:ol.E;NOIO OP!ol2A,11:.D WIJ~ &1.11\. '1' R l:.l,OW Cct,(iA.o..__ Ace UMU LA. 'j'O I.I: NIT ROC;6N c,14,a..;:2c.1N,; 'e>Y"oTE.M TY ?1c;u.1. ;eoa T"'-'O.,'T'~TE""~ ---,J J CJ>,.(la SOLENOID OPERATED VALVE w/ DUAL COILS VERSIONS/REVISIONS BY NPPD SIGNIFICANT NUhlBER GROUP A-t 11t* S.5. ._.., *...,FILT.E.~f"----*4+-' 27& NOTES
- 1. ALL ITEMS TAGGED WITH 3-ARE SUPPLIED BY OTHERS.
- 2. PRE-ASSEMBLED HYDRAULIC CONTROL UNITS WILL BE SUPPLIED BY OTHERS.
- 3. ALL INSTRUMENT LINES ARE 1 /2" S.S. 80 UNLESS NOTED.
- 4. SOLENOID VALVES ARE SHOWN IN A DE-ENERGIZED POSITION.
- 5. VENTS AND DRAINS TO BE RUN TO NEAREST BLDG EQUIPMENT DRAIN.
- 6. REFERENCE EE 05-010 FOR JUSTIFICATION OF PIPING MATERIALS.
DRAWN DATE 4 CHEO<ED DATE AS BUILT 454015155 STATUS: Release STATUS DATE: 11/21/2022 DS APPROVED: CAJOHNS VER: AB REV: 15 SIZE: F REACTOR
- CONTROLS, j
NO. DESCRIPTION ORDER DFT DATE ENG AC 14 DR-2022-0354 5415213 LS 10 17 JWWOOD AB 15 DR-2022-0265 5411175 DLR 10 29 2 CA.JOHNS COOPER CRD NUCLEAR STATION HS DIAGRAM APPROVED DATE I N C. tl SEE-EDED ~ 8 1---,"~--~-----------i C FILMED CP-001 ~}}