ML23129A422
| ML23129A422 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 04/20/2023 |
| From: | Nebraska Public Power District (NPPD) |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML23129A261 | List:
|
| References | |
| NLS2023022 | |
| Download: ML23129A422 (1) | |
Text
1 A
B C
D E
F G
H
(/)
z 0
U)
~
J 0:::
ci z
1 RANGE
.01-100 MR/HR
.1-1000 MR/HR 1-10 4 MR/HR 100-10 6 MR/HR (TYPICAL)
AREA RADIATION MONITOR WITH OPTICAL ISOLATOR DRYWELL SENSOR &
CONVERTER (HIGH RANGE)
RE-40A LOCAL TYP (40B)
RAD 2
SENSOR &
CONVERTER RE-2, 11, 12, 14, 16, 17, 20, 21, 22, 23, 28, 29, 30 RE-4, 5, 6, 15, 25, 26, 27 RE-18 RE-1 MONITOR (HIGH RANGE)
PMIS TABLE 5 RM-40A CR TABLE 1 AUXILIARY UNIT RM-AU2, 11, 12, 14, 16, 17, 20, 21, 22, 23, 28, 29, 30 RM-AU4, 5, 6, 15, 25, 26, 27 RM-AU18 RM-AU1 POWER PANEL CPP I
I I
3 INDICATOR &
TRIP UNIT RA-2, 11, 12, 14, 16, 17, 20, 21, 22, 23, 28, 29, 30 RA-4, 5, 6, 15, 25, 26, 27 RA-18 RA-1 4
AI.ARM MODULE AM-2, 11, 12, 14, 16, 17, 20, 21, 22, 23, 28, 29, 30 AM-4, 5, 6, 15, 25, 26, 27 AM-18 AM-1 (TYPICAL)
AREA RADIATION MONITOR CHANNEL WITHOUT AUX UNIT SENSOR &
CONVERTER RE
- I LOCAL
- TABLE 2 5
TABLE 2 RANGE SENSOR &
CONVERTER
.01-100 RE-3, 7, 8, MR/HR 9, 10, 13, 19, 24 INDICATOR &
TRIP UNIT RA-3, 7, 8, 9, 10, 13, 19, 24 6
TABLE POWER SUPPLY ES-53A ES-53B ES-53C (TYPICAL)
AREA RADIATION MONITOR CHANNEL WITH AUX UNIT PMIS TABLE 4 PMIS TABLE 4 SENSOR &
CONVERTER CONTROL POWER FROM LOCAL 120VAC DISTRIBUTION PANEL I
I I
AUDIO ALARM AM-* I LOCAL RE
- I LOCAL
- TABLE 1 I
I I
t AUXILIARY UNIT RM
- I LOCAL
- TABLE 1
- TABLE 1 I
I MULTI-CHANNEL POWER SUPPLY FOR AREA RADIATION MONITORS
~-----r-------------------------7 I
I I
I 8
3 TABLE 4 CHANNELS PMIS SENSOR &
POWERED INPUT POINT CONVERTER 1-10 N091 RE-1 N092 RE-2 11-20 N093 RE-3 21-30 N094 RE-4 N095 RE-5 N096 RE-6 N097 RE-7 N098 RE-8 N099 RE-9 N100 RE-10 N101 RE-11 N102 RE-12 N103 RE-13 TABLE N104 RE-14 N105 RE-15 N106 RE-16 N107 RE-17 N108 RE-18 N109 RE-19 N110 RE-20 N111 RE-21 N112 RE-22 N113 RE-23 N114 RE-24 N115 RE-25 N116 RE-26 TYP (40B) 9-2
- TABLE 3 ES-* I CR t
t
__._*--~'---
OPTICAL ISOLATOR I0-40A CR TYP (40B)
CONTAINMENT RADIATION RECORDER (MULTIPOIND 9-2 RR-40 CR 9-2 (TYPICAL)
AREA RADIATION MONITOR WITHOUT RECORDER, WITH OR WITHOUT AI.ARM RW (WITHOUT ALARM)
SENSOR CONVERTER RE-45A LOCAL RADIATION MONITOR RM-45A LOCAL (WITH ALARM)
SENSOR CONVERTER RE-458 LOCAL RADIATION MONITOR RM-458 LOCAL 2
18-53 A,B,C 9-11
- TABLE 2 RA-"'
INDICATOR TRIP UNIT I
CR RA-*
INDICATOR TRIP UNIT I
CR I
I I
9-11
- TABLE1 I
I I
9-11
- --L __ L __________________________ J I
I I
I I
I
~--r-----------------------------~
I L---------7 r----------J I
I t
t AREA RADIATION RECORDER (MULTIPOIND RR-55 I
CR POWER FROM
/
120VAC INSTRUMENT BUS 9-2 DOWNSCALE TRI PS
7 I
r-------~----*---~-------~--------~-------~-------7 I
I I
I 9-~R ADMINISTRATION HIGH RADIATION HIGH RADIATION ALARM I
9-~R CONTROL ROOM HIGH RADIATION RA-458 I LOCAL I
9-~
REFUELING FLOOR AREA HIGH RADIATION RADWASTE BUILDING AREA HIGH RADIATION (TYPICAL)
PORTABLE AREA RADIATION MONITOR MPF RADIATION DETECTOR RE-60 TYP 61 62 LOCAL RADIATION MONITOR RM-60 LOCAL TYP 61 62 TIP ROOM HIGH RADIATION REACTOR BUILDING HIGH RADIATION (TYPICAL)
AREA RADIATION MONITOR ARW RADIATION ELEMENT RE-*
LOCAL
- TABLE 6 RADIATION MONITOR RA-*
LOCAL
- TABLE 6 TURBINE BUILDING HIGH RADIATION 9-k!;;R AREA MONITORS DOWNSCALE RANGE 1-104 N117 RE-27 N118 RE-28 N119 RE-29 N120 RE-30 TABLE 5 PMIS RADIATION INPUT POINT MONITOR N063 N064 DETECTOR RE-31, 32, 33, 34, 35 RM-40A RM-408 TABLE 6 AUXILIARY UNIT RM-AU31, 32, 33, 34, 35 RADIATION MONITOR RA-31, 32, 33, 34, 35 AUXILIARY
-PWR IN FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.
UNIT (LPAR 1)
REVISIONS BY N.P.P.D.
RM-*
CR NO.
REVISIONS DFT CKD APP DATE
- TABLE 6 DRUM HANDLING N01 REV & REDRAWN PER APA DCN C93-1813 DR JAC WCF 10-26-93 CONTROL ROOM N02 CED 6014761 (DCN 05-1374)
DLR JDN KZ 2-1-11 3
4 5
6
~
8 3
9 10
-53A POWER
~CHANNEL SUPPLY 1
2 3
4 NUMBER 5 I 6
7 8
9 10
-538 POWER 11 12 13 14 SUPPLY 15116 17 18 19 20
-53C POWER 21 22 23 24 SUPPLY 25 126 27 28 29 30 INDICATION Ile TRIP UNITS FOR EACH CHANNEL WILL BE ARRANGED PER CHART ABOVE 1 1 SIGNIFICANT NUMBER GROUP 1
2 3
4 5
COOPER NUCLEAR STATION FUNCTIONAL CONTROL DIAGRAM 12 llQIES;
- 1.
SENSOR & CONVERTER TO BE MOUNTED AT 7 FT ELEVATION FROM FLOOR. AUXILIARY UNIT TO BE MOUNTED AT 5 FT ELEVATION FROM FLOOR.
- 2.
FOR SENSOR & CONVERTER LOCATIONS REFER TO INSTRUMENT DATA SHEETS.
- 3.
FOR LOCATION AND IDENTIFICATION OF INSTRUMENTS SEE INSTRUMENT DATA SHEET LISTED IN MPL FOR EACH INSTRUMENT.
- 4. ALL COMPONENT NUMBERS PREFIXED BY 18 EXCEPT WHERE OTHERWISE SHOWN.
REFERENCE DOCUMENTS
- 1.
791 E268 AREA RADIATION MONITORING ELE.
- 2.
791 E267 PROCESS RADIATION MON SYS.
- 3.
CNS-EE-78 MPF LLRW PLAN AND DETAILS.
INFORMATION ONLY 452005509 DRAWN I DATE DR 10-11-93 GENERAL 6
I DATE CHECKED JAC 10-29-93 ELECTRIC I
DATE APPROVED WCF 10-29-93
~
Ii:
FILMED REVISION AREA RADIATION MONITORING SYSTEM 921D796 SH 1 N02 ~
9 10 1 1 12 A
B C
D E
F G
H r---
CX) 0 J
~
~
0 0 u