Text
{{#Wiki_filter:A B C D E F G H j 1 2 3 4 5 6 '----'------7-------'-----s---------'------g-----'-----1-o ____ ..J..._ ____ 1 _1 ___ ___Jc.__ ____ 1_2 ___ ---,7 SEE DWG. 200 7 ZONE C-4 I SEE DWG. 2007 ZONE 8-4 ~ Cl. Cl. N en I Cl'. "' w 0 f- <{ I,< Gl "' f-z I :J -o 0 (.) 'N - 00 ~ I f-u z WW f-> z Cl'. ~ N Cl'. I o: vw 0 f- <{ I,< Gl (.!) f-z I :J -o 0 u ' N I <D 0 I t'i I I t'i 927 928 BAY "A" 14"-10 ..-----N------, />---~ 14"~5CV 2" TEC-1 2" TEC-1 00 N I ~ (104) [ 84"112MV S-126
- VENT [;+::;:-.__L---,1:w_(}------j I
8 I ~ I ~ I I I ~ SCREEN WASH PUMP INTERLOCK 1-A I RIVERWELL SYS. DWG. 2006 SHT.5 ZONE G-2 BAY "A" 00 I 0 0 I,. u I 00 Gl f-929 0... N I u ~ INTAKE YARD STRUCT. ICE CONTROL TUNNEL 84" CW-2 930 931 932 936 933 934 BAY BAY BAY BAY "B" "C" "O" "E" SLUICE GATE (TYP.) 935 30" DIA. M.H. '--F'l-~ "D" TO "E" CROSSTIE C.W. SUPPLY TUNNEL 156" CW-1 1/2" TEC-241 00 I 0 0 1/2"TEC-243 00 I 0 0 1/2"TEC-245 00 I 0 0 1-8 (105) [ 84"'113MV S-126 I ~ I RIVERWELL SYS. DWG. 2006 SHT.5 ZONE G-2 BAY "B" I,. u I 00 N... N I (.) w f-M 1-C (106) [ 84"114MV S-126 I,. u I 00 CW-V-1043 I ~ I SEE ',----{ NOTE 15 CW-V-1045 RIVERWELL SYS. DWG. 2006 SHT.5 ZONE G-3 BAY "C" CIRCULATING WATER PUMPS I,. u I M ~~ H:io:J-_J L MO 1-D (107) L. 84"115MV S-126 00 CW-V-1044 SEE I NOTE ~ 15 I CW-V-1046 RIVERWELL SYS. DWG. 2006 SHT.5 ZONE G-4 BAY "D" Jc w z 0 N [~1-'i 10 RV-4x6 RELIEF VALVE SET @ 180 PSIG INTAKE 1 PUMP ~ ~ 680 142 STRUCT. ROOM 729 152 154 _J 153 102 ~ FOR FLUSHING SAND FROM VALVES WHEN,.i ONE PUMP IS OFF ~ SEE DWG. 2006 SHT. 2 ZONE C-2 14or--'---t-:lh 141 '( TO WASTE VENT 1/2"-13 (672) 3/4"-(681) 3/4"-682 ["t/8bRAINER) ~ ~ S'----1/f-_J--f'-.J--DL.l..!:8~*-lt::--'"-<--10*(573) n I"'--..- 12" G-iF-<:J---'--L........r---, I 1 O" WW-1 [-0-.----'-'-"--=i---'--I/ H t---1~-~c~w_-~1~01_-_1~0~/t-r--I 1 2 1-A (96) I 0 I " 0 I,. u I 0 ( 1 01) 2" -21 ,------r--- '( I ~ TO I V RIVER : 2"-698 --.._ DRAIN VALVE N.C. (100) I I I I c_--,,~,-ll O" WW-1 ,-.I----------,-[ s ' 0 - o I 0 - SHT. 5 ZONE F-4 0"'
i TO SCREEN WASH CONTROL SYSTEM RIVERWELL SYS.
THIS DWG. SHT. 5 ['-+.., 691 145 143 r--'---t-:lh 144 I ' 0 3/4"-693 I ' 0 3/4"-692 FOR FLUSHING SAND FROM VALVES WHEN ONE PUMP IS OFF 0
- V" 74 -CW-1 11 RV-4x6 RELIEF VALVE SET @ 180 PSIG I,
TO WASTE VENT 1/2"-16 (684) (97) --Y 'f I SEE DWG 2006 -~ -~ S' SHT. 2 ZONE B-2 MO 1-SW-109-14 14" SW-2 PRIMING & EMERGENCY 14"-116MV CW-1 SW-2 SCREEN WASH SUPPLY 1195 ZONE E-4 ')" I I I I I
- J,, CW-20CV 2"-783 18" SW I8"-39 SHT. 5 ZONE F-6 SEE THIS DWG.
SHT. 2 ZONE C-3 14" SW-2 8" B.F. (FUTURE CHLORINATION SYS.) SEE NOTE 9 SCREEN WASH PUMPS UPSTREAM DOWNSTREAM ~ WAT~EVEL WATeEVEL _[_ - -I PANEL I I I I I 842 717 n 703 712 181 A "A" STRAINER 701 0-I ISCREEN-CONTROLLY l-L CW-PNL-Al_I--------~ 4 (TYP. FOR BG! SCREENS) <D N " I I I 714 I I I LI 702 700 I 7151 I I r.; 3/4" (TYP.) '713'716 841 711 --.._ 1 o" -697 i-.-1-1 3/4"VENT 857 10" 10" CW-1 SEE THIS DWG, SHT. 2, ZONE C-2 INTAKE PUMP STRUCT. ROOM TO FIRE PUMP 1-CW-109 10" FP-1 DISCH. HDR. l-t><l-1...1..:.....=....:..1"'0':,,-_""1 o"c'v.it"f-1_.0~.. _f-2.,.2--'-'----~ SEE DWG. 2016 SHT. 1A 704 705 LI I I 1708 PIS 71 840 [ 728 159 J f-+,!,t--,--J;><H 163 IA-PRV77 1 61 BYPASS GATE SWITCH m m _j __ _ BAY "A" SCREEN A 1 2,, SCREEN A2 2" 991 992 1 1/2" H:Y 2" 981 982 2"SCREEN 81 2* 993 983 BAY "B" 2"SCREEN 82 994 984 N I,. en ' 0 N N ~ 0 I,. U1 I N I,. en N N I,. en ' 0 N SEE NOTE 15 SW-V-1536 SW-V-1537 A 1-SW-lOOA-20 20" SW-2 1-D 20"' SW-2 ,20*-13 H--tl0t--~ S-129 20"'( 13-CV) (202) 1-SW-108-1 1.. _ 1256 U) N 1255 1 "-31 ~ A 1-8 20" SW-2 20" SW-2 ,20*-11 0,1--~ S-129 20"(11-CV) (200) 1-SW-108-1 1"-1250 ~ FE _li!il_J_ A 61 ~ -w 1"-1249 ] 1"-30 A 1-C 20" SW-2 ,20"-12 20"(12-CV) 0,1--~ S-129 (201) 1-SW-108-1 1"-1253 ~ ---10 1"-(1252) A 1" SW-2 0 N ~ 0 20" SW-2 --.._ 20*-10 20"(10-CV) (199) t-,t---1011--~ S-129 1/2" (lYP.) 1-SW-108-1 1" SW-2 1"-1247
- 10.
U)... N ~ -@---0 1"-(1246) 1"-23 NOTES:
- l. "C-P" INDICATES LOCATION OF CATHODIC PROTECTION LEADS TO BE INSTALLED IN ACCORDANCE WITH PARAGRAPH 1.4.14.2. CONTRACT E-69-4.
N I m 0 0 ~---------- ---------------- ---------------------------~1"-24 1" SW-2 1" SW-2 1-SW-1088-1" 2* AT SAMPLING POINTS, CONNECTIONS, PROBES AND ROOT VALVES SHALL BE FURNISHED AND INSTALLED UNDER CONTRACT E-69-4. PROBES SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH CONTRACT PARA. 3.4.2 AND DWG. SP-07211, FIG. NUMBER AS NOTED. CONTINUATION OF SAMPLE PIPING BY E-70-3. N I,. en N BAY "E" 1----__J r.; 335 336 333 331,:..._.."'.._:,332 334 LI ] (1187) L_ ----- '--I..;;;.;;,+-' (1188) r.; JNSNUB-2 342 343 JNSNUB-6 340 338 344 339 [---I f---] 1234 ~-t;:Hi<,---~ 1235 341 3/*' -210 20"-194 -+--g 20" SW-2 ...__. __ --1/1---------------~ ] y TO RIVER N I ~ VENT 345 SEE THIS DWG. SHT.2 ZONE H-5 18" SW-2 303 204 H-~ I 355f---M--~ 356 I 357 358 360 305 301 r.; r.; ~---< 0 I') 306 302 304 ~~] 1183 '---lmtt-' 11 84 L _________ r.,_ 310 INSNUB-1 312 31 3 INSNUB-S 308 314 309 [----1 J 1231 ~--ttrn-r-~ 1232 311 3/4-208 STATION SERVICE WATER PUMPS (1080 c~L 1079 ~-er 347 348 346 351 _ _er 350 352 349 1081 NC 3 NOTE 13 88CV ~ NOi~ 89CV ,+ 0 QUILL I I ---v SWBD L PUMP ~AUTO START I') ~ PUMP ROOM INTAKE STRUCT. NOTE 14 IF (1225) NOTE 13 90CV QUILL SWNC YARD 24" SW-2 24"-72;:::. 24" >---r>--------i-~-------w--.-1/~f-l----'---+---H-=sw~-~2-' L ____________ _ 00 N ' I ~ 317 316 18 319 214 18" SW-2 1/2" 7 I I (1226) IF -1239 321 LEU VENT ~1080 HM-J u, w I "'ti I ~ en z I ~ ~~ >L_ 7 V u (/) ~ I 1 --.._u, "' o I ~ 0 20 st ~ 'lt ~ N ~ ~I~ 87CV PStr0 ~ j -..,._ 16~--- l Ly NC QUILL JI s= I 22 PUMP 4* 38 I AUTO M_ /...._._~ VENT I 323 START ~ ~ L_JL_ ___ ~ _' ___ vr17-J-~ ~ °' 211 i;;::::::a-0U--~~ ~ ~ NOTE 13 NOTE 14 /f---it--'---r-1---+'rl----'-~ IF I I I I I I I I I I (.!) w z 0 N ci ~ en
- r:
f-
- r:
en w w en L -c FOR CONT.
- 3. CLASS IS SEISMIC REQUIREMENTS FOR THE "SW-2" &
"CW-2" SYSTEMS SHALL APPLY TO THAT PORTION OF THE SYSTEM IDENTIFIED AS CLASS IS SEISMIC HEREON. ALL SW-2 PIPING DOWNSTREAM OF 24"-1490 IS CL-IIS. (REF. E-10)
- 4. UNLESS OTHERWISE INDICATED ALL PRESSURE AND/OR FLOW INSTRUMENT ROOT LINES SHALL BE 3/4", ROOT VALVES SHALL BE 3/4"-V232S EXCEPT AS NOTED, LINE UP TO AND INCLUDING ROOT VALVE SHALL BE FURNISHED AND INSTALLED UNDER CONTRACT E-69-4.
- 5. ALL TEMPERATURE. TEST AND PROTECTING WELL PENETRATIONS SHALL BE 1 "NPT UNLESS OTHERWISE NOTED.
- 6. 156" CW-1. 108" CW-2. 84" CW-2 TEMPERING LINE AND PORTIONS OF THE CW-1, CW-2 AND SW-2 SYSTEMS ARE NOT IN CONTRACT E-69-4.
FOR INTERFACES SEE COMPOSITE PIPING DWGS.
- 7. VENTS & DRAINS SHALL CONFORM (FULL LENGTH)
TO THE SYSTEMS DESIGNATION FROM WHICH THEY ORIGINATE.
- 8. ALL VALVE NUMBERS IN PARENTHESIS (
) ARE NUMBERS TO BE USED IN OPERATING PROCEDURES. THESE NUMBERS ARE ASSIGNED BY NPPD AND WILL NOT BE SHOWN ON PIPING DRAWINGS.
- 9. ALL VALVES DOWNSTREAM OF SW-116MV ARE IN THE CIRCULATING WATER SYSTEM (CW) UNLESS DESIGNATED OTHERWISE. ALL VALVES UPSTREAM AND INCLUDING SW-116MV ARE IN THE SERVICE WATER SYSTEM (SW) UNLESS DESIGNATED OTHERWISE.
- 10. WHERE LINES ARE INTERCONNECTED AND CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROX.
ONLY.
- 11. PRESSURE REGULATING VALVE FOR TWS SCREEN WASH SUPPLY IS MANUALLY ADJUSTABLE.
- 12. INSTRUMENT ABANDONED IN PLACE.
- 13. HOSE CONNECTION FOR CHEMICAL INJECTION LINE.
- 14. CHEMICAL INJECTION QUILL AND ASSOCIATED COMPRESSION GLAND, CHECK VALVE(S). AND HOSE CONNECTION MAY OR MAY NOT BE INSTALLED. IF NOT INSTALLED, ISi BOUNDARY/CLASS BREAK REVERTS TO NEAREST CLOSED VALVE (1519, 1523)
FOR CLASS 3 BOUNDARIES.
- 15. CHEMICAL INJECTION LINES FROM SW/CW CHEMICAL TREATMENT SYSTEM TO SW/CW BAYS. THE SW/CW CHEMICAL TREATMENT SYSTEM, INCLUDING ISOLATION VALVES CW-V-1043, CW-V-1044, CW-V-1045, CW-V-1046, SW-V-1536 & SW-V-1537 IS A PROCEDURE 0.31 EXEMPT SYSTEM CONTROLLED SEE THIS DWG, SHT. 3, BY THE CHEMISTRY DEPARTMENT. THESE INJECTION LINES TO THE SW/CW BAYS ARE PLASTIC TUBING AND ARE NOT PART OF CONTRACT E-69-4.
x- ~ ( 1178) ] 1385 ZONE H-7 PI 394 "Fl>4-'J n 1478 1474 1475 ""-----+--] 1462 ['-I---:,- -+--g 20"-193 20" SW-2 '----1------l/f----=N-=r-""--=---------,-----------' I (315) 1 1/2" SW-2 1/2" 1470 1.. SW-2 1468 1457 ~ LI VENT ' <D SEE THIS DWG SHT. 2 ZONE J-4 AUTOMATIC BACKWASH STRAINERS BAY "C" BAY "D" 1 1/2" SW-2 BAY "E" 1480 1469 1479 1.. SW-2 1455 1" SW-2 1456 2.SCREEN C1 2.. SCREEN C2 SCREEN D1 SCREEN D2 2,, SCREEN E 2" 2" 2" 1" SW-2 995 996 H:Y 2" H:Y 2" H:Y 2" 1476 985 986 987 988 989 1" SW-2 ZONE B-7 162 123 27 1000 NOTE 11 1001 NOTE 11 1002 NOTE 11 1003 NOTE 11 1004 NOTE 11 1005 NOTE 11 1006 NOTE 71 1007 NOTE 11 *1 1008 NOTE 11 1489 IA-PRV76 PCV373 1------1/ ~~~}---i / 8.. PCV-373 10"-23 10"-24 118 8"-25 86 8" 1 158 2 1 o* WW-1 PS [ 160 164 2200 (NOTE 12) J 727 156 157 3 49 /55 26 1009 1010 1011 1012 1013 1014 52
==,... =,...
==,... =~
==,...
==,... =~ ~ ~ , -cw-1 02-1 o L"'..L-..L...!.1,,_o *_* -'w'-'w'---'1-"s'-'-"'.1-------'----D"'..L_.,_ __ ---1 '---,-"'..L_.1---______ .,,.,__1---"'B_" --'w'-'w'--_1c,s'--"'--'--..L--{>---, 1-"'~-~--=--"'~---r-~----1 '--[)---' .r 6°' WW-1S cs ss WW-1 WW-1S " w w0 f-z 1/l <{ >- :r: 1/l u 4 "'4-__ 21/2"-778 TRAVELING SCREENS 5 21/2"-29 6 7 REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY. 8 454003586 STATUS: Release NOTE: ALL ITEMS MARKED THUS 0 ARE "AS BUILT" ITEMS AND ARE NOT SHOWN ON PIPING DRAWINGS. AS BUILT STATUS DATE: 02/02/2022 OS APPROVED: KKKUKER VER: AO REV: 91 SIZE: F VERSIONS/REVISIONS BY NPPD NO. DESCRIPTION ORDER DFT DATE ENG AO 91 DR-2022-0001 DLR 2 22 KKKUKE 9 SIGNIFICANT NUIIIBER GROUP 4 FLOW DIAGRAM CIRCULATING, SCREEN WASH & SERVICE WATER SYSTEMS COOPER NUCLEAR STATION 10 1 1 DRAWN DATE CHEO<ED DATE BURNS & ROE <D 0 R APPROVED DATE Q SEE~~ ~ 8 1----r---~---------i C FILMED ~ 2006 SH 1 12 A B C D E F G H j}}