1 to Updated Safety Analysis Report, Drawing 2028, Flow Diagram Reactor Building & Drywell Equipment Drain System
ML23129A413
Person / Time
Site: Cooper 
Issue date: 04/20/2023
From:
Nebraska Public Power District (NPPD)
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23129A261 List: ... further results
References
NLS2023022
Download: ML23129A413 (1)


Text

{{#Wiki_filter:A B C D E F G H J 1 2 3 4 5 6 '--.,___ ____ 7 ____ __j_ ____ s ____ __,_ ____ 9 ____ -'-____ 1 o ____ ---'--____ 11 ____ ...J..._ ____ 1_2 ___ ---,7 "B" "c" "D" "E" "F" "G" "H" MS-71ARV MS-SPV71A IA-1625 PS-256A IA-1815 ACC-256A IA-17CV NONE MS-71BRV MS-SPV718 IA-1626 PS-2568 IA-1816 ACC-2568 IA-18CV NONE MS-71CRV MS-SPV71C IA-1627 PS-256C IA-1817 ACC-256C IA-19CV NONE MS-71 ORV MS-SPV71 D IA-648 PS-256D IA-1871 ACC-256D IA-36CV IA-650 MS-71ERV MS-SPV71E IA-1628 PS-256E IA-1818 ACC-256E IA-20CV NONE MS-71 FRV MS-SPV71 F IA-649 PS-256F IA-1870 ACC-256F IA-37CV IA-651 RW-SOV-A094 ~ y PRIMARY CONTAINMENT 1-- - - - ---c ISOLATION I SYSTEM ,--------_, _____ 7 I RW-SOV-A095I ~ 9~ i -~~


- -t --- + - ----

1 PS "D" I DRYWELL PENETRATION RW-V-959 MS-71 GRV MS-SPV71 G IA-1629 PS-256G IA-1820 ACC-256G IA-21 CV NONE MS-71HRV MS-SPV71H IA-1630 PS-256H IA-1819 ACC-256H IA-22CV NONE ACCUMULATORS ARE IN THE IA SYSTEM PRESSURE SWITCHES ARE IN THE MS SYSTEM I I ~ i I R~S I RW-V-1033 TO RW-V-256 I:'! z w r--.:a,, I VlI w z w :;:: w z z 0 "'oo N N FUEL POOL HEAT EXCHANGERS 1A & 1 B TUBE DRAIN ELEV 958' -3" N I N ~ a: 3" ' N I N 3" "'z I<< I<L W£L z-o°' NO .m I w w z 0 N -,i z"' << I £LC) £L w -z "'o ON <( IO... ~ fl.I (/) ~

'.:? (/)

0 => ~

J 0 I"') a..

a.. I") 0 u 2 u 0 Na_ CL N CJ LL (!) LL G

S: 0

~ 0 :S: 0 I-I- 0 "H" a, ,--7 1 ,--7 L ___. I "E" "G" "c" RW-V-961 I AO I I I AO I --,j~I I lji~,-~ IA-V-9021 C 0 IA-V-9021 B 0 FROM AUTO BLOW DOWN /------ C..,,'-'-,----C:<<J-4.,..._c_J ON ACC-256A, B,C,E,G,H ONLY IA-V-9022C IA-V-9022B I I I I /---------c*J---------------------t*}---------2 TO DICHARGE /----ti,"A" FOR PIPING T INTERRELATION 1----_J SEE DWG 2041 ON ACC-256D,F ONLY DETAIL "A" DETAIL "B" INSTRUMENT AIR FOR RW-A094 & SAMPLE SINK J I (/) 0"1 "'o I LL N w c,z

00 ON RW-A095 ZONE B-6 12-4-36 INSTRUMENT AIR FOR SAFETY RELIEF VALVES is! "'

z 01 -N <( a;; ~w 12-4-35 ON OZ ~ 2"PW-2 ~ v s:t-1Y o '-+-'----'=-,[::I,. SEE DWG 2042 a,: c, I I u N 5" I O ID W ~.., SH 3, ZONE ~ :< N I I H-5

..Jo w ~ ur,r')

~ ~r-- i:i:i---: ~ 2 O 3:: I o fl. I 1 4"CF-2 =,Z O 2 N 0:::(f) a..0 UW ~N ~t-,.

JW 3:>

~r--...f' ri 0 V a.. I (l)Z 0::::£~ a..6 I I a:~ o..O 2 SEE DWG 2042 2"PW-2 SH 3, ZONE H-5 XI-"'--'-"'-=-~ 2--1---------2 12-4-248

?::;;j:W 0....

(/) (/)

JW Z

oa:::w =>w N Cl Vlz o h 1"CU-2 SEE DWG 2042 <t:Oz Vlza, 0 I:< -o u..,- LLwo -OV O

JO ON

= I SH 3, ZONE ONO u z .N 4"CF-1 1 2" s-------_J_---s N ~ N z N N h o h ~(/) 12-4-24A I F-3 I o. o * ~ u..,- c I

,O('\J u...t-C) Cl "<t-z = :r:

I SEE DWG 2042 Xl---'1_"c::..u::..-_2=-i 1 3"CU-3S /-' <(I ~-"~ ~ '° ;;;-::; ~(/) RWCU 1 SH 2, ZONE E-8 ,,__L ______ _, --(fl 1 j 1" r c I HOLD. 1 ,,_3_(;_LJ_-_31_ --2 L I I PUMPS 1 MISC EQUIP DRAINS RWCU PUMP 7 I I 1A, 1 B, I N @ COL. 9.3 RO_O_M_E_.D_. __ --=-.-LJ..!..f----~.L.L,. E.D.


,t,~7-------- I 1---------

~~~ 3" 3" 3"PW-2 3 £L ~ 1-RW-100-3" £L CL 0 0 a: £L

, sj-

£LI (/) 3"PW-2 3"PW-2 ~ LL w }--1c;_u_-_2 i RELIEF VALVE DISCH. N FROM NON-REG HEAT 1 EXCH. DWG 2031 /E SH 3, ZONE C-10 3" "- c.o. I 1--"--_.:,,.__,,3,__,"p:.!w~---=-2 _______ £L RELIEF VALVE DISCH. FROM } 1 "CU-2 NON-REG HEAT EXCH., DWG 2042 SH 1, ZONE E-8 1-RW-100-3" wZ (/) ;"' <( I 0 0 I ~ 3" 3" 4"PW-2 z - w 0 RW-V-960 RW-V-958 RW-V-1034 TO RW-V-257 RW-V-962 DETAIL "C" AVSPV739 ~ 0 4" C)"'

< I ow

>-z 25-56 CONT ON DWG 2010 SH 2 c----Ji ZONE E-6 MS-CV-38CV ~ 1/2-:.!vsPV -738 Z"PW-1 X-301 PC-V-561 I PC-V-563 X-33e CONT ON DWG 2010 SH 2 ZONE E-7 PC-V-564 MS-CV-39CV 4'V153W{571) PS ~-0 102 I ~ 2 25-5 48BCV w S' N <( Pl 101 1 'V276W (228) X-28F 1*~s1 I I -~ UVl ~ 1.&..o 00 2 25-5

  • ,._ "'o J.

CONT ON A~1~JJ7 PC-V-559 --...N - DWG 201 oc-;--. ..-,"' ~ SH 2 PC-V-560 X-30e ~,. o ZONE E-6 1 I ~o N f-----+r__:,- NBI-CV-59CV CONT ON 1- _ I PC-V-565 DWG 2010 SH 2 t----1 ZONE D-6 0 "' t m z NBI ::Cv-socv 24"MS-1 r-- PC-CV-36CV ~ I PC-C_'{;:35CV FOR PIPING INTERRELATION SEE DWG 2041 ZONE 8-7 PC-V-591 <O <D I >u I u £L a, I LI > I u £L -45 VACUUM BREAKER r. 2"V353X(12BCV) BULKHEAD DRAIN f:l'l-11MS-;_1 BULKHEAD PLATE 1-MS-151-2"I 2"V263X-105 2"PW-1 2"V263X-106 2"V263X-107 2.PW-l 1-RW-120-2"1 1-RW-120-2' 7 o 1/2"738AV J:(0 976P 1/2"739AV976P SEE DWG 2026 2"MS-1 SH 1, ZONE A-6 1-MS-139-2" DRYWELL SEAL FLANGE REFUELING BELLOWS ASSEMBLY I (/) I REACTOR HEAD FLANGE SEAL DRAIN 11/2" PW-2 3'V1 23W-165 1-RW-121-3" N I,. £L REFUELING BELLOWS ASSEMBLY il, (/) "' ~ 5 z w w LI Vl -I ,- ~ _ _l__~ OPEN TO ATM 11/2'1/253X-166 0 ":'_ - _J_~ 3'V353X{85) 3"PW-2 __ 2' -0" -LOOP'-'---- 18" SEAL - I c::;:;2ocv _I v121 CV 2'V353X{129CV) ';' VACUUM - ,o BREAKER

p.

10"685SV168W TEST oe "' PACKING DRAIN /;j [;; DWG 2045 SH I '° Lim ZONE C-10 'ff' 5J ~ - J 1o'VR-1 1-MS-127-10" 1 PW-2 ME III \_-', '"'"-- -'-'-------{),0--- (902) CC, C _I_, I AfJ I 22CV 100117 L __ _J ho 23CV T~ TO DISCHARGE BELOW r,;,;;;,,i-- _. AH WATER LEVEL INSIDE TORUS. DWG 2027 SH 2, ZONE G-5 0 SPARE 1 1/2"PW-2 11/2'\i153X (580) 18"GV1 68W PACKING DRAIN. DWG 2044 b ZONE D-10 I 3/4" f----, ~ TEST uR 3/4" X 00 1,-.,,"'0 ~~W LO ~ a, 0 (/) .-.... <C ~.... >--~ - ~-----< I I ~ FOR PIPING _!L:="_ __ ------2 INTERRELATION 24"MS-1 SEE DWG 2041 ZONE C-4 t;; z

, ucn"'

,...,- I e-Oo RELIEF VALVE DISCH. FROM REG HEAT EXCH.. DWG t. 2042 SH 1, ZONE E-8 ~_1"c_LJ=2__ I a: £L O <( =, ~.... u a: I TEST ~~+--r"~4("F";!LI i:' 3/4" 18"GV168W PACKING 7' x ~ < x ~ N38 --------~L


{>,'1--------

(904) CC, C _I_, 5CV f £,",,j l:f~ I ~ FOR PIPING ~ INTERRELATION 2 4"Ms::_--,----2 SEE DWG 2041 ZONE 8-5 \;! N w o~z <t:>0 LLON SAMPLING RACK DRAIN, DWG 2043 N o ZONE C-10 1 tn fo 1-tn fo a: "1 C" DRAIN ELEV 931 '-6" 1-RW-102-3" ,. <( (t'. £L w (/) 4" 4" 3"PW-2 ~----,~~ 1-RW-102-3" DRAIN FROM SLUDGE AND DECANT PUMPS FOR PIPING INTERRELATION,,24"MS-1 SEE DWG 2041 ZONE B-7 X-7D FROM RHR HEAT EXCH 1A SEE DWG 2036 SH 1, ZONE C-6 3"C.O. 1,------l.J:"P~W'.::-~2-~ FROM RHR HEAT EXCH 1 B 3"PW-2 I NORTH SCRAM DISCHARGE INSTRUMENT VOLUME. DWG 2039 ZONE H-4 ELEV 903' -6" ELEV 881'-9" "' I I a: ELEV 859' -9" N I 1E

  • N NOTE:

<D J_ w a,Z ..,-o 0N N C)..,-

<:r 0(1) z c2 VENT FROM RHR 1 A LOOP. SEE DWG 2040 SH 1, ZONE E-4 0

1 1/2" FROM RHR HEAT EXCH

l 1 A. SEE DWG 2040

!J! SH 1, ZONE F-1 (/) 3" 2"X4" JET PUMP INSTR. RACK "A" N I 1E

  • 3" I,.

£L I 0 _._, 0 I? N I,. £L sj-1 SEE DWG 2036 SH 1 ~ VENT FROM RHR LOOP ZONE C-9

18. SEE DWG 2040 SH 2, ZONE E-9 CRD EQUIPMENT DRAIN SEE DWG 2039, ZONE F-8 (N.E.)

(N.W.) 3" 3" 3" 3"PW-2 FROM RHR HEAT EXCH 1 8. SEE DWG 2040 SH 2, ZONE F-12 CAPPED IN STEAM TUNNEL

11. "

1 /2 SEE DWG 2041, ZONE C-11 SEE DWG 2044, ZONE C-9 N N N I I I £L £L £L i-r) i,,-) i,,-) 3" FROM SOUTH

l SCRAM DISCHARGE w

INSTR. VOLUME iJi DWG 2039 ZONE H-2 3"PW-2 1-RW-103-3" CRD EQUIPMENT DRAIN SEE DWG 2039, ZONE F-9 MAIN STEAM FLOW INSTR. RACK DRAIN (S.W.) 3"PW-2 (S.E.) <D -J_ Ow N z c,0 ,ON 0 w WI (/)(/) -----~ rrm rm DRAIN FROM HYDRAULIC DRIVE PUMPS u CRD MASTER EQUIP DRAIN N I,. £L ;,, 1'4'\IENT TO SUMP 20"546SV1 68W & 20"500MV1 68W BODY DRAINS DWG 2040 SH 1 ZONE D-10 DRAIN 24"535SV168W DWG 2040 SH 1 ZONE C-10 LEAK-OFF 24"535SV168W DWG 2040 SH 1 ZONE C-10 -,---------~-7---------- 3/4'\1253X-54 1-RW-118-3/4" I I a: RHR SYSTEM (PUMPS 1A & 2040 SH 1, ZONES F-7 & H-7 SEE DWG c, :r u,1, (PUMPS 1 B & 1C) DWG 1 D) DWG 2040 SH 2, 2045 SH 1

0Vlo..,-

SEE DWG ZONE o I I 1 D 3 LOl.i.l.- O OJ ZONES F-6 & H-6 2045 SH 1 w..,-z - 0 / - -- -----2 ZONE G-5 I ~ ?l 2 I I ~ I-- ____ I-+' 1 l / --.1- ---,-1 ~ ~ j / --,1- ---,-1 ~ ~ 'f 1 \ :_ _1 1 sEE DWG 1----~----+_; 1 1 r---+' 1 1 RHR PUMP 1 B 2045 SH 1,_.., \ ,1 t' N J, \ -,1 t' N I '1 ZONE G-3, I I CORE-SPRAY I

' 'f 'f I

I CORE-SPRAY I '--1__.,----,' ~ -& PUMP 1A ~ I ~ -& PUMP 1B ~ t' ~-!......+--- I ' ! N 3;: I ~ I i 1 "PW-1 °'

r:

I I I 3"PW-1 3"..- RHR-PUMP °' /E 3"PW-1 3',o -1...- 1 D 1 I


<c-----1

£L I I 1 1 ~ RCIC-A013 Ll_j 3/41 ~~ ~ ~~~LL ) _J" I,. £L ~ t'- ~ ~ ~ N RCIC SYS. c---{_"}-- 3 -2 "'L...,-,..., 3"PW-1 "' I DWG 2043 I C,Oj f-1---'--Cl--'-"'1 /E ZONE H-9 ~C-4 !PW-~ 1-RW-138-4" 4"PW-2 4"PW-2 1-RW-112-4" 4"PW-2 4"C.0. 6"C.0. ' "' I I I I 3" 3"PW-2 ~- (12RV) I 11/2" 1*100 11--.L,===~~~L41,. "' N2 REACTOR BLDG N6 1 EQUIP DRAIN

cl!: ~

SUMP HEAT I 1-RW-119-3/4" N5 EXCHGR 20-9 N 1 AVSPV735 I l" :g 711/2" DRAIN I I TO SUMP I X I '-_J? 1-RW-116-2" I Y 2"734AV153X -TTsA~o r~i_, L J RMS ~ 'I' 98 I I R~s I ~-~~'iJ~ 2"PW-1 ~ 00 n:~_ : 1 2"PW-1 . ~ ) 3"PW-1 1-RW-113-4" 4"PW-2 4"C.O. I 1--_:,,_----'-_L_-~ '----------------"'"--'--"'---'-----------'--'-"--=----------/ I '7 3"735AV123W'i ,-__f'.._ _____ ~ _ _J'\_ ____ __f'\.._ ___ ~ j I N "1 2 p -1 L-------- N I,. £L L-0 A L FROM HPCI SYSTEM --.------,. _,,------,' SEE DWG 2044 j ZONE H-9 _fW-1HP-4.,. 0---*-b."~"i;sc+------, <<l N I I ~,. £L I ' ,. <D a: I 1 u;> Pl I u;> Pl C'\I ~--------r X 90 I X 90 I ,::::::,,:;J ,:::::,,:;J ,.._ f---+-a'as-i ,-N~ ,-N~ 1E-1 ~ I [ ~ 1E-2 ~ I [ ~ I x> I x> I ~ "'u "'u ~ lt".I_._ lt".I,,... l""l~ I l""l~ I I ?~ 3: ?~ 3: N a::: N C::: MV/1 533 SW ¢::~ ~ 3/4v253X(253) 20 9-19 I


~

534 AH ALL ITEMS MARKED THUS 0ARE "AS BUILT" ITEMS AND ARE NOT SHOWN ON PIPING DRAWINGS.

  • Y

~IS -0 I REACTOR BLDG EQUIP DRAIN SUMP 1 E & PUMPS 20 9-4 L ______________________________________ 1 _______ _ NOTES:

1. INSTRUMENT SENSING LINES UP TO AND INCLUDING THE ROOT VALVES SHALL BE FURNISHED AND INSTALLED UNDER CONTRACT E69-4.
4. ALL "MS-1" PIPING SYSTEMS SHOWN HEREON SHALL BE CLASS "IN" NUCLEAR CLASSIFICATION.
5. ALL EQUIPMENT DRAINS EXTERIOR TO DRYWELL TO BE FURNISHED WITH LOOP SEALS.
10. FOR 1A CONNECTION, SEE DETAIL A. TYPICAL FOR MS-71, ARV, 71BRV, 71CRV, 71DRV, 71ERV, 71FRV, 71GRV, 71HRV.
s::

.._ z .._ h-+'mt P-.;>ow.;>LO -.N -.N O Cl. -.N 0 ,.._ 0 <D 2 v1 L __ _J 27cv 26cv r,,;;,r,1-- - l~ TO DISCHARGE BELOW ~ N3D 3/4'VENT WATER LEVEL INSIDE /;j :g TO SUMP TORUS. DWG 2027 '° a,' SH 2, ZONE G-3 ~ /E 3/4v253X-5B 1-RW-131-3/4" 24"540SV168W ~ - 1° (908) d:: l-----('t9x0:l-'7)-+,~ x '° 34CV 1-_,-;;><J---t,,m:rl;,- c_--{:<<)-----'--=__.:.:::..:.., PACKING DRAIN 1 1/2 PW-2, 1-RW-284-1 1/4" DWG 2040 SH 2 [ 7 1 ZONE C-3 TEST 'li7:v4" ~ (13RV) I ~ la'"'c N

i
;;

v1 ~,_.,00;> N 32CV ~ ~ v'1 v,_ N33CV n:? I ,,-~1+1/2_" ______ 24"540SV168W<'-:-::---. ~ 7' I,b ~ "'"'~ <D 35CV

SI AH
c. I

.'-,__~;:,~-,; -.,..._--:- TO DISCH~RGE BELOW WATER iiii1i 32-l00 N2 DRYWELL EQUIP N6 BODY DRAIN 3/4" xfLI,n £L DRAIN SUMP oo I HEAT EXCHGR ~Ms '° i§, N5 20-10 N1 0 .v4" :v4" :v4" INSIDE TORUS. SEE DWG 2027 SH 1 7' 7' 7' ZONE G-5 1 1/2" /'Jill'\ o I ~ '":"'.'~::---1 ~ ,-b'.c 1 ~~ 11/2"Pw-2 0 PW-1tRL-1S 2"P~-1

"RL-1S DWG 2042 SH 1, ZONE G-3

-=--' MO 2"730MV1--+;~;;;~+-i 93 -153X 2'V276X-162 2'V276X-22 !}>SEE DWG !lit:: 2027 SH 1

, o ZONE E-5

£L 11/2"DRAIN FS-21A PUMP A DWG 2027 1 1/2"PUMP ZONE F-9 CAVITY DRAIN ~ DWG 2027 SH 1, ZONE F-9 -RW-320A-3" \ I I I I I / / 3"PW-2 4"PW-2 t;; w r-- f'4°'DRAIN FROM FS-26A DWG 2027 ZONE F-9 ~ 2"PW-1 DRAIN 0 SUMP 2"PW-1 2"PW-1 1-RW-129-2" I "PW-1 I RV-27RV 3" 1 1/2DRAIN, FS-21 B PUMP-B, DWG 2027 SH 2, ZONE F-5 !J l 3"731MV123W I 3/4"DRAIN, FS-26B 1 PUMP-B, DWG I 2027 SH 2 74 L ZONE F-5 LI VENT FROM DWG 7 PI~VT276 2027 11/2"PUMP 3/4",.J ~ SH 2 CAVITY DRAIN '°' ~ A x 2"PW-1 ZONE DWG 2027 SH 2 LI I x y ~1 ~~ 1 D-5 ZONE F-[Ej

j~

X-18

  • "' I 00 N

I,. a: I 11/2" L N N ~ X 2"PW-2 3"PW-2 II:, ~I - ___,.-'i ~ 1 - - - - - ---' '-- 1 7 ~

i ~

/:\Ci I 1 ls-1 I I,"- (254)0 ~ ~ I

lg I I~

~ 3"1/123W-17~>- -;:._ f---1.,.~I-~, ?'¥ I /;j

~1 Id, LI 1-RW-320B-3" NI")

lO N lO I"' N r-- N"1 11/2"PW-2

> 1

,c:::.:.:,, I;;!, r PUMP CUTOFF ON VALVE ~ I"' > 3" 732AV & 733AV CLOSURE ~ 1G-2 I.i_ I ~-----------~ --------:::-,, '~~ ,b Jy,_ --~ "--t-+----,:J'.g @ ¢:~ t --@--_-I Ms;,' I =- ;~~ -~ ~ 3*;~~wv ~ I AO SEE DETAIL B 2D 20 9-19 20 ( 94 (334) (333) -I 1G-1 I I c_ __ =--P'. o f!J DRYWELL EQUIP SUMP 1 G & PUMPS L O C ju 123 I AfJc 2 NC m 3"733AV - -u'. ~ ~--- 3"PW-2 & 4"PW-2 TERMINATE BELOW ELEV OF PUMP LEVEL SWITCH SUPPRESSION CHAMBER 1-RW-115-3" SIGNIFJCANT NUlil:IER GROUP 2 4 AH L'-------"=-"J-~--l-;:'-1

  • v 95 3/4 253X L..:.::...J--,~

SEE DETAIL B AS m (255) ~VENT REACTOR BUILDING WALL BUILT DRAWN HFY 9/17/02 CHECl<ED DATIC y SEE DWG 2033 SH 2 ZONE B-1 454003618 STATUS: Release STATUS DATE: 10/20/2022 DS APPROVED: EDSOREN VER: AF REV: 56 SIZE: F VERSIONS/REVISIONS BY NPPD BURNS & ROE <O N a,

2. FLOOR AND EQUIPMENT DRAIN FITTINGS AND PORTIONS OF EMBEDDED PIPING FURNISHED AND INSTALLED BY OTHERS AS SHOWN ON DRAWINGS 2183, 2184, 2185, 2186 AND 2187.
3. DIFFUSER PIPE IN SUMPS TO BE ~" DIA. ENCIRCLING SUMP. DIFFUSER HOLES TO BE 1/4'DIA. APPROXIMATELY 1 "o.c.
6. ALL VR-1 SYSTEM PIPING INSIDE OF THE DRYWELL IS SUPPORTED TO CLASS IS RESTRAINED CRITERIA.
7. ALL VALVE NUMBERS IN PARENTHESIS ( ) ARE NUMBERS USED IN OPERATING PROCEDURES. THESE NUMBERS ARE ASSIGNED BY NPPD AND WILL NOT BE SHOWN ON PIPING DRAWINGS.
8. 1" Pl-1 S REACTOR VESSEL FLANGE LOW PRESSURE SEAL LEAK OFF PIPING CONFORMS TO CLASS "IN" REQUIREMENTS FOR MATERIALS, EXPLANATION AND FABRICATION (EXCEPT THAT THREADED JOINTS ARE PERMISSIBLE WITHOUT SEAL WELDING). THIS LINE IS ATMOSPHERIC DRAIN LINE, AND NO HYDROSTATIC TESTING IS REQUIRED.
9. TYPICAL VALVE NUMBERING CODE FOR 1 O" VACUMN BREAKERS (LOCATED DOWNSTREAM FROM RV 71A THROUGH H) IS 1 O'V359F.
11. INSTRUMENT, SAMPLE, TEST, DRAIN AND VENT LINES ARE NOT ALWAYS THE SAME CLASS AS THE MAIN LINE AND THESE BOUNDARIES ARE TOO NUMEROUS TO IDENTIFY IN THIS MANNER (SEE ISi PROGRAM BOUNDARY DESCRIPTIONS FOR DETAILS).
12. CB IS PRIMARY CONTAINMENT BOUNDARY.
13. WHERE LINES INTERCONNECT AND ARE CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROXIMATE ONLY.

REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY. NO. DESCRIPTION AC 54 DR-2019-0001 AE 55 DR-2020-0001 AF 56 DR-2022-0422 ORDER DFT DATE ENG DLR 10 4 19 LJJENSE DJB 9 01 2 T2STEVE 64084 DJB 10 20 EDSOREN COOPER NUCLEAR STATION FLOW DIAGRAM REACTOR BUILDING & DRYWELL EQUIPMENT DRAIN SYSTEM 0 APPROVED 0 ~u f----.---~----------1 C FILMED 2028 1 2 3 4 5 6 7 8 9 10 1 1 12 A B C D E F G H J}}