1 A
I -
I I
3 I
0 IL 1L IL 0
CL N
B C
D I
I -
3 I
I I
I 0
IL 3
IL 0
CL CL CL N
N -
E F
G H
J 1
2"FDR-1 2
I 1L N
~~~
I I
I 2
~
~
I I
I I
-I IL i-'
-I 3 :,;
-I 3
o._
-I >
o._ * "'
3 B~~ ------<;)
(RW-V-1206)
LEVEL 4 FILTER LEVEL 3 FILTER LEVEL 2 FILTER LEVEL 1 FILTER POWDERED RESIN TYPE 3
CONTAINER
-I >
o._
- N 4
4 5
6
'--.,___ ____ 7 ____
__j_ ____ s ____ __,_ ____
9 ____ -'-____
1 o ____ ---'--____
11 ____
...J..._ ____
1_2 ___ ---,7 3/4"DEMIN FLUSH WATER MATCH LINE SEE 2032 SH 3 N
I i-' -
-I 0 IL
,----~
I I
3/B" SA-l DWG 201 0
~
- +:::~:::-1--.,,,_-----,cl'\lf--------'-'----=---------'----'---------< SH 3 1020 RW-SOV-SPV10 ZONE B-12 N
I
,o -
DWG 2032 SH 4 ZONE A-6&7 N
I i-' -
N I
i-' -
DWG. 2032 SH. 3 ZONE A-10 (RW-V-1208)
RW-TVM-DSF 1 "
11/2" 1 "CU-2 1-----l-~H-=i-------------------------"------=--------------.----'---------,
NOTE 10 rr-AO-- ::-7 (RW-V-1223)
---c TO LINER TV MONITOR 5
1
- RESIN SAMPLE POINT
{RW-V-1218) 11/2"
{RW-V-1219) 11/2"
{RW-V-1220) 11/2"
{RW-V-1221)
{RW-V-1216)
.v,"
DEM IN.
r-----1.... --~__c_7---- FLUSH WATER
,--@---7 I
I I
I THERMAL
,--------------_J I ENCLOSURE I
I 11-
-II I
(RW-F-H 1 S) 1/4" I
.!E FI' I
I so2 545 I
"-=
I
~--~
I I
-I > I MESH
~,----~--,
2*
{RW-V-1217)
Yi'
{RW-V-1222)
ENTRAINMENT SEPARATOR PORT FOR USE 4*
W/ BEAD TYPE lf-----L-------l41~'---__J RESIN CONTAINER COALESCING FILTER SA-F-FCC 1/2"sA-1 3/4"SA-1 DWG 2010 L---'--=-='--'----cJ------,--L:c'---""'-----'----< SH 3 1/2" RW-SOV-SPV610 'A--------'-"'-----'
FILL STATION>--~
SUMP PIT 4" FDR DWG. 2017 ZONE E-4 4"
SA-607 DEWATERING PUMP RW-P-DSDP
{RW-V-1211) 2" (RW-V-1213) 2" (RW-V-1212)
RW-F-BDCB
~
()
0
"' I IL I
3
~~
HEPA COALESCING FILTER FILTER RW-F-DSHF TO ARW BUILDING ATM.
ZONE B-11
~
i';:
o._
0 (Il I
IL I
3 RW-F-BDPFB
<L-.L..L' PRE FILTER
~
~
<D N
N N
N
-I -
Pl I
820 I
Pl I
3 3
819 DEWATERING SYS.
BLOWER RW-BLWR-DSB TE --~
614 3"
MATCH LINE SEE 2032 SH 4 REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY.
4" FREON CHILLER RW-CH-DS VERSIONS/REVISIONS BY NPPD
_J NO.
DESCRIPTION ORDER DFT DATE ENG 6
7 8
AB 09 DR-2013-0599 DCN 13-2061 AC 10 DR-2022-0092 INSTALL TCC AD 11 DR-2022-0092 REMOVE TCC 6014761 OJB 8 04 1 GEHORN 5435640 DJB 17 2 KKKUKE 5435640 DJB 3 15 2 LJJENSE 9
RW-P-DSSP SIGNIFJCANT NUlil:IER GROUP 3"PW-1 DWG. 2032 SH. 3 ZONE A-10 (RW-V-1207) rl:ll!h NOTE 10 rr---- 7 AfJ I 1013 I
LL,'. ____ _J AfJ 1012 CU,;-21FD.f1-1
-I 0 IL DWG. 2032 SH. 3 ZONE A-10 NOTE 10 rr---- 7 I
AO I
I 1019 I
L_L ____ _J AO 1018 N
I i-' -
' 1--,:,:::+~
I 1015 I
L': ____ _J AfJ 1014 CU;-21P'(!-1
-I 3
o._ * -
I -
I 0
3 IL o._
- 1.
WHERE LINES ARE INTERCONNECTED AND CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROXIMATE ONLY.
2 4
FLOW DIAGRAM AS DRAWN DATE HFY 10/1/01 CHECl<ED DATE 454223017 STATUS: Release STATUS DATE: 03/15/2022 OS APPROVED: LJJENSE VER: AD REV: 11 SIZE: F BURNS & ROE a,
a, HIGH CONDUCTIVITY (FLOOR DRAINS, CHEMICAL & LAUNDRY WASTE) PROCESS COOPER NUCLEAR STATION 0
0
~o t----,--~---------;
C FILMED APPROVED DATE SEE~~EDED 2032 SH 5 10 1 1 12 A
B C
D E
F G
H J