1 to Updated Safety Analysis Report, Drawing 2006, Flow Diagram Circulating, Screen Wash & Service Water Systems, Sheet 3
ML23129A369
Person / Time
Site: Cooper 
(DPR-046)
Issue date: 04/20/2023
From:
Nebraska Public Power District (NPPD)
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23129A261 List: ... further results
References
NLS2023022
Download: ML23129A369 (1)


Text

{{#Wiki_filter:A B C D E F G H J 1 I 2 I 3 I 4 I 5 I 6 '---------l...1 ___ 7 ___ ---'---1 ___ s ___ ..L_I ___ 9 ___ L__l __ 1_o __ ______Jl ___ 1_1 __


1.l ___

1_2 -----,7 FROM ZONE F-2 TCC NUMBER: 11470720 / (THIS DWG.) ---~ ECM NUMBER: DR--19 INTAKE YARD 13 DRAFTER: DJB --cS~T""RccUccCTc-./t----'=cc_- J CATHODIC JUMPER FROM ZONE F-3 -----I~ ASSIGNED ENG: JDIIADOO '° / C.P. /, PROTECTION (THIS DWG.) .DAIE; 11/21/2022 d, i--'8e.:,4:..."_,C,_,W=2'-J+-'~',---"u"-=_:~~*------------------------....'..::=.....::.::_:::::._ ___ _....:~ ____________ _!:8~4~" _,C~W~2c.._ ________..'.::=========::::'....-. <':~:1 I ~ ~ rn I 1c RMS sp / PROTECTION S 128 I / ' '---l:(C = ~ JU~ER ~~2 / "0 L>-< DC 156" CW-1 J, -....Y!,. / I >-<- n I J TE C I X (110) I 199 (111) K g~ MO ~ 1/4~-+--11-,- FIG. 2, / J ' ' / 96"1 OOMV811 F~ I ' CW-V-91 O< C.P., Gs) 96" Vle--...L.+--,--ln1-cw-101-96 r,, (179) DRESSER COUPLING 1-++-~--='---0 1 L,J -0"""'"-'--1'.u,-t (180) / \...I r\..J S-127 G / (108) IF '--r-,-.--",.~.,,.,--< 30" DIA. MANHOLE -------..J W:U I / ru Y (819) HEATING BOILER ~~:g--1 (304) (305) _[" ROOM FLOOR / IQ FT u _J,. '\ ~ , : 28CV 29CV, : 13 , -im,:J 'i' 1..~-' ~ - NOTE 2 r\ ID SUMP- / L ~-'=' {193) -] s-128 54* n PUMP n I c194) .o, I,1----"---'-lc-t 202

  • 203 G

84"104MV811F { I ~-~'~'~ u LJ I ' 30"DIA MANHOLE co n-Dc ll"oc _J ~ 'l EAST OF CDSR 1-A I CONDENSER 1-A 'T' T 3" BLIND FLG FOR_ _j r;,-,,, TEMP. PROBE MO RMS z C) ~ w --1 C) NEAR A L ) c ) dicv1 =-;:5J PRIMING VALVE (TYP. 8 PLACES) CW-STNR-14PV t--~--t-:H"-- 10PV 2"V253X


~ 1 2 253X 14PV 0

11/4"V253X-71 _ CW-STNR-10PV "V ~1/4"V253X-73 II -67 ~--,_, -69 11

  • "'77=h-t:.:i-,-l--5 A-1 A-1 r.J,... L_1_*v_2_5,1)31(JXf---53_,a ___ ---\sl INLET OUTLET 1(--trl 1*--I 1 'Y253X(542) ~

N I t v lAt11/4"V253X-72 \_ CONDENSER 1-A J ~- ~1/4"V253X-74 ~ 1PV 2"V253X ~ ~ 2 v253X 15PV "f--!Xf--,--t -68 1--~ -70 I m 1 A", 1 "V25_3~-539 I A-2 A-2 ~ INLET OUTLET '\. 1" V2~3~(543) 0 ~(fc-wi--S-T-NR---11_PV ___ c_w ___ S_T-NR---15JPV7 J~--' [efA CW-2 (TYP.) CW-1 (TYP.) CW-1 (TYP.) CW-2 (TYP.) 12PV 2"V253X,._\.,,--f-----------,....,,.L.., 2 v253X 16PV -75 -77 N I u,.,. 11/4"V253X-79~ [CW-STNR-12PV CW-STNR-16PV J ~, ~1/4"V253X-81 B-1 B-1 f A /L_1 *_v_2-{;53*X1---5_4_o __

___ "'l, __ --I INLET OUTLET IC--+,1-l)o:J----,,

1 'Y253X(544) ~ 11/4"V253X-80~ 0 CONDENSER 1-8 T ~1/4"V253X-82 13pv 2"V253X ~ 2"V253X -76 -78 l.-0 B-2 B-2 A NOTE: FOR NOTES SEE THIS DWG SHT. 1 1 "CW-2 SA-1 CW-1 (504) t - FROM DWG. ,~, ~ 2010, SH.3 cC-~,- T,--(-1)'<}--') _ _J__,141Ttf,--L---, ZONE G-8 (503) PRV10 (129)

i-519RV)

PUMP , - ____ }PRIMING II CONTROL PRIMING VALVE (TYP. 2 PLACES) \ -~.-\----~ ;;, N co 1 'V253X-2404 ' (531) N I ~ N I 3 1/2" 1 BPVf-'-'-C-H:J-.J.-!>< "'H p 1...-r~1/2 V153X-530

: 3/4"V253X-532 1 "x 3/4" INSERT (822),,

(310)j ~ & 7 J I / / ! ~ (308) 7 , 1 NPT WELD COUPLING / PLUGGED FOR FUTURE FLOW TEST DEVICE (TYP.) n /TE\ & <( ~ I u IA.I .-["L --iv, 1 'Y253X-541 I I INLET OUTLET I 1 Y253X(545) lAY'-----l)(I----..-___J1-L------h~ 8" CW-1 1 I 1 -- CKT. I I EXISTING 1" VENT----*y ~ N *

  • r--- "

u Pl ~... r-- u SPARE PS A H / / 96" TE O I 11 / MO u wO 'C7 ~,..,_c I I ' / CW-V-911j 'i' 'i' ,-~~'i'~J: I r-+--s-i~,~~2_7__.__... n,-1~ S-128 84"10~MX811F84" T L c"., ~~ ~~ -J O 11, (\ FE 'f:,r:r:lc_1_12_) __ (_2_0_6) ____ (2_0_7_) __ (_1_13j)T;,-,4'Y11F-62 g)::f-...,M~O--' ~-t--t-FIG. 2,,,. O O co L....-:r---C-l-,--jM--l-l)Q-----j O)::f- _J I NOTE 2 Cl u (126) (36CV) T-G / YARD BLDG / 108"CW-2 0 ( CW-STNR-13PV CW-STNR-17PV l 4" CW-2 1 "-CW-119-4 1 Yi' CW-1 co I - 1"-CW-111-8~ I CW-2 8'Y123F-526,: -,u ~CW-l 'ix, 4'Y211 F { (170) A----;----, -555 I.. I,,......U.---'-.U......,..\

  • PS 373
  • Pl 373 I

I I I A

  • A. I

/p5\ PS ~7,V 375 1'Y232S-59 C - TBCCWHX 1-A S-411 N co / / / / / / / / / / ~-~g FT 12 I & c? J:;(c ~_l= '

Z(815)
  • I 208 J (812);,

c ~ SP 3/4"V546X(B)(120) R"S ~o <J) 4'Y111 F-60 / LJ 17Ac OPT\ /\ 24"SW-2 --7 '~ OTO . I~ (~o~) \so9) <sos) I ""--r------~ 1 ..v1 VACUUM TANK (130) 11/2"' ~ PCV10 19PV Yi' ~ 96"101 MV811 F I C.W. SYSTEM FILL 1-SW-111-12 84 "109MV-811 F 1._ ____,-____ M 1""""" __ 1 __ ---'8'-4'--"c""w""--2=-----'-1 _-"'cw""--'-1 o"-'3'---'8"-4'----i I < 7 N 0 ~ -,:, u 211**212 u LJ ~ rTPil ~ ~~ ( 1 71 ) '<1--'-,:_____;___:_J 2" (83) t FROM DWG 2013 ~:;-s1 ;c" i°D""W;-;-f.c!S;'-:;-,--C"""'"--'1/2=-'-',cDW,:--"=IS'------, ~ (134) .v" '14 CW-1 7 (136) 1 "Y253X-2402 (529) ..__,_,1/2"V153X-527 N 3/4"V253X-528 t l, 1 "x 3/4" INSERT "'4----'===i (820) I <D / / 1 l 1 O"CW-2 T-G I/ J_ 0 0 84"110MV-811F 84"CW-2 1-CW-103-84 BLDG ,t-lf-YCCA-'CRCCD_ l'.l" C Jf c 1,.;;,..,...------'---""--"-"-~--------'---"",-'-""---"'-'--------1-i ZONE C-12 1-DW-108-1 1/2"V226S-185 8" CW-1 1-CW-111-8 3 ~ I ;; / u ~T-r,'.;oi ).I 4'Y111F-63 ~ ~ 4'Y111F-65 0 108"CW 2 / I / ,;: y / / / / / / 0 ~ 0---rn .. '~--~ /\ ~,~ ~ /sP\ I/ ~ s-1281 (816)2'. ~21s): --T21sT~ ~ ~ 1 0 ~ J;, 1r l:<f ; I 1 'I/ TE c~ 7 1 3/4" V546X(B) J:S'- MO ~ '~ r---------<-i "(114) I 217 (115) Ow MO (l 2l) 96"102MV c n n c= ~

  • 1 I
  • 1

+--+- FIG 2, BLIND FLG

/ I / u / <D ~ / / / / v j tt~---'-T""r,-----,, 1--,--f-i (184) c19o) """'"--<101 I, 30* DIA CW-V-912 <) 'J G (220),::. (221) G 84"106MV-811F M.H. IF ~ "' uu I

JIEAST OF u

CDSR


~_/ '

l../"'y;x::)-J @ BB-~ ~ Jfg J:;(g 3" BLIND FLG FOR g ~iR ! ~ (3o5) (307).7~" N1 (818) ~ i6 c ,-;c;:7-_J TEMP. PROBE ~ WALL CONDENSER -/ MO RMS ~ 7 30CV ~.~ -BB .-1.... 1 -8 w 33CV.- 7 u -.;t- /\ FT fFE\ ~ t(311) ':.,.N ~ 11 \11 ¢n ~u I' 7 r,1-CW-101-96 !!l io ' J IF ./ 'u' i'LJ' '-+;:::=,----~ 'i' Cl 7 N ~ ~ (312) ~ 96" I S-127 'i' {§85) {§87) S-128 84"10,7~Y811F T t 1-¥-1--f:--.:..-...L.- )1,1-~-f-+--f-+-4-l-1, HO ~ c'., ( 186) ( 188) .o 11 1 ~ ~ / ~ _ CW-V-913< L.GR:T'-TL ____________ _JfG'--r-"Y,7,, ~ 0 / 96"103MV MO I N c'., -/TE\ /\ 0 MO X ~> / -B11F , "7 ~ ;l, u ,':(116) V (2_24.) (2_25.) (117)" " 54 ~ cl=f-...,...,..~ !:!- ~ ~+--,-FIG 2, .L ~.U N 00 ~ ?

  • n. '~

Q ' I ~ NOTE 2 I/ / / / / J. / {SH !ELD )::( g pg N 1 N I,, ~-T,(8,;1",71) -i:-J-i.--1-f-

  • -,JXlf-----j,
  • 7 cl=f- ~_J ;:';

SP WALL ~ r--1=~, I 226) (BlO).. 7 4'Y111F-66 RMS C.118- / en en

  • }.

~ I /:, N ..:t-7 OPT\ I - 5.3 v 1-CW-110-3 3" VENT & STATIC_/ TEST RISER / / / / ~ <D <.J LO ...,_ 'V 3: C C 1-- __..---..-_L- <n I I ~ N >'&.. 'o.._ ( 1229 ** 230 I I - - r C cw.-1jCl)!-2 3 U) U) ~ ~ cw.-4 Cl)!-2 I 54"111 MV-811 FI I ,\:'.}-~TO ZONE ,.12* TO L.... _______ L....l _ _ -"8""4_,"Cc,:We,_-_,2:......:..1 --~---1'--_,Cc:.Wc..-..:1_.:,0o::3_-,,::84.:_ _____ -I 827 H_~J CAPPED I w Cl w z 0 N U) I ~ ~ -I u N I ~ / "' co ~ 21/2" 1; 8RV A-3 ZONE I I N A-3 L ___ ~ ~

l, 1,

/ [><J- / 1/F. C. :c.::; ~ ~~ 17 / W>N_,, fFG\ ~ fFG\ QB 4"SW-2 L..J ~ RV-2233 ~ ~ u 17RV '.'° "' ,,,-'-'Cl fFG\ fFG\ QB 98 12"811F-860 LOCKED CLOSED ~-.-..----'--'-""'-""--'-+---'-------- _-.,/ 1......._r't\... ~ ----~i 24"cvr1 1,/F-54 24"SW-2 (BACKWASH) 1-SW-102A-24 / I j_ 1,,--------~-~---'----------------~ ~'o...i 1" VENT 00_ _ tL ro:,-...P!i/Xhl---()3_9<11f---{;1*87l---J /TE\ /\ (TYP.) ~ I/ N I ~ v N ~ ~ 1 'Y232S-59 ~ I IAI IAI TO WASTE 3: TO WASTE....,J--J,.i- ~,-n:LlJ-11""°""-----n--l:ni7,7,~~,t,--[ ~ N ( 5;) 1 'Y232S-60 l-A L ______ AIR REMOVAL r--

l,f-
:4'--,+
  • J---J'.i-*'-~,--11r----:=-t1-TT-i:::!!~1-*v~~~~~~s~-~61 7

£1) l TO WASTE...., 1...,. 1 188 1...,. 1 ._ TO WASTE ,....._ ~ ~ j T/G BLDG. L -(}-7 v N I N 0 - I,;: I - DWG 2006 6.. SW-2 SHT 4,.,!---',- 1 ------'""--"-I ZONE G-3 I L~ 72 278 INTAKE / YARD STRUCT. I/ N I 1" N - ~ 1 'Y232S-62 /px\ * * /TE\ /\ 00 '&.. \367/v F \367AJ ~ 393 u VENT 0 =:._- 1-SW-102A-24

~
0 ~t'

~2""4'-""'s"-w_-"'2-t-'/+--c-,,.t-P 1_* --+/+--HI f--' 1...,_~-i. 1* fl

/\

~.t"-0 24"SW-2 24"SW-2 / 1 1/4" V123X-53~-. / / / / I/ I/ I/ I/ I/ I/ I/ I/ I/ FX (ANNUBAR TYP.) fil 1" DRAIN (TYP ) (231) 24"CV811F-56 24.. SW-2 JSW-V-1298 24"v811F-55 N .--'---l:/~l----"-'---'---"-(~B'-AC'-K'-W-'A~SH~) ____ ~_.._ ______ ~1/:f--TT_.__-::-:-::--'---,-,-,--,-----~ j 3/4 '1/546(6)(295) L~=l(::jH(";;;\~Sij;PcJ 24"CV811F-63 FIG 2, NOTE 2 ov, ~ 1---i'/f------"2'-'4-'"s'-'w'---'2'--'-(BA"'-,C,'-K"-W'-A-'-SH-")'-_1_-..,cs_w_-_1.c.o.cc2c.B---"-24 ___________ ~ 1" VENT fPX\ ~92 189 /TE\ /\ 66 ~ 1 'Y232S-67 66 \ (TYP.) TO WASTE TO WASTE J--14 '**'f--=-i --' 1...,.1 lt->-~--10-----ll--'-il I 1...,.1 1 'Y232S-68 l __ AIR 1-B REMOVAL ~ ~* **1-*_!!:;r-11-----:-=-:--tt--rrcl!....:.1 ~*v-1.,2iii"'3i*2s~--e::.;:s .e TO WASTE ,~, I ~ 190 ~TE,~~-, TO WASTE ~-=:._~ 1 'Y232S-70 I PX\ I rr \ 67 67 C co-r-394 1-SW-102B-24 v 24'Y811F-65 l" DRAIN (TYP.) JSW-V-1299 24"V811F(64) N ~---<:/~l-----2_4_*_s_w~(B_A_CK_W_A_SH~)----~-~--------1l/:f--TT"_.__-:: ________ j 1 3/4 '1/546(6)(296) ~ (Sp\ TURBINE BUILDING CLOSED COOLING WATER HEAT EXCHANGERS FIG 2, NOTE 2 1.......--'K,, v:1,H\:,Y-. 57" 9rl v N I

§ 0

I U) I - N I 0 0 -I ~ I co 0 I v 0 I t I - I v 0 I t I - YARD v CX) I 0 -I 3 u I - D-G BLDG 84"CW-2 108"CW-2 108"CW-2 TO ATMOSHERE (ROOM) t 6" V-1 OVERFLOW 1" VENT CW-* ~ 926 ' ,lci (421) TO DRAIN Y I (TEMPERING WATER SUPPLY) Yi'V526S-184 TO ATMOSPHERE (ROOM) 6" V-1 t VACUUM PRIMING PUMP 1-B 1-CW-111-6 6'V111 F-85 1-CW-111-6 6"V111 F-84 NOTE: FOR VACUUM PRIMARY PUMP COOLERS SEE DWG. 2007 ZONE D-10. WATER BOX PRIMING DIAGRAM

  • FURNISHED WITH VACUUM EQUIPMENT 1-CW-105-84 1-CW-104-108 1-CW-104-108

-,I,- ,..,,-SEPARATOR LCV-703 VACUUM PRIMING PUMP 1-A CW-923 OVERFLOW J CW-925 1" VENT (420) Lr:.n I y TO DRAIN 1'V2329-67 EXISTING ,~, 1 VENT TBCCWHX 1-B TURBINE BUILDING CLOSED COOLING WATER HEAT EXCHANGER AIR REMOVAL DIAGRAM I/ 1-SW-133A-10 } - ,-------f:~+--'1_--=S.:.:W_-.:_1,::33:c,Bc:._-_1c,O:._ ___ 10" SW-2 SUPPLY & RETURN TO DIESEL GENERATORS #1 & FOR CONTINUATION SEE DWG 2077, ZONES D-1 & D-4. --{ 1-SW-134A-10 2 - ~ - 1-SW-134B-10 Cl _J (D I/ 3'V123W-109 EMERGENCY COOLING WATER FROM CONTROL,,_ .3~" ___ 1_-_sw_-_1 _13_-_3_~., ROOM A/C UNIT, SEE DWG 2007, ZONE H-1' r, 3'Y1 23W-11 o r, 3" 1-SW-115A-3 3'Y1 23W-113 1-SW-113A-3 3" 1-SW-113B-3 IF 3" I/ N I 13 Cl Cl ';c EMERGENCY COOLING WATER FROM AIR, I I I/ , ~ , / COMPRESSORS, SEE DWG 2007, ZONE F-1, G-1. 3* 3"v123W-114 1 / C.P.,, ,,C.P. 1SW-115B-3 I/ _J w z z C) ~ w C) <( I u U) Cl FROM RM-17-352 DWG. 2031, SH.3 ZONE F-6 I I I I ,--m--, (;> 17 9-2 (;>

&~

~g : 2" FROM CONTROL BLDG BASEMENT VENTILATION ~~"-----'1"'-""sw--.:..:.:1:.:17:..-_:2:._ ____ -{::lx::)---------L..J~I' ~ !o~ ~ _:u, I/ CONTROL SEE DWG 2006 SHT. 4, ZONE J-5 ~ ~ - ~-----+::-+-_B_L-DG---~24~*~*s-'w_-~2 __ -~ ~~i~sw-B & --'c'-'oB"'NL"'~R"'coccL=+-+ ~ I YARD.~ I/ I TO RESIDUAL HEAT REMOVAL SERVICE WATER BOOSTER PUMPS, I REC-SW-B N I u ' 0 I I I I u ~--- 13~~AI ~ ---~ I 11 s-10 1~0 I SW-2 CW-2 I/ I REACTOR BLDG HEAT EXCHANGERS AND CONTROL BLDG SERVICES, I HEAT ~--+-t-----~2=4-"~sw~-=2 __ SEE DWG 2006 SHT. 4, ZONE A-2, E-2. I EXCHANGERS ~ I ,r---"-'--""-=----'--"--'="---'---+---c-t I/ 0-I I 24"SW-2 1-SW-104A-24 A 7 I FROM REACTOR BLDG RESIDUAL HEAT REMOVAL & CLOSED I (0 ~ _ '1

I

~ ___ HEAT _EXCHANGERS, _SEE _owe_ 2036 ~HT~ 1_'._ ZO~E-E-12. _ _J,..1 _F_R_O_,M2'-'4-'"s"'w'---'2=----'-1--'SCCW'---1:.:0c.;4.=B_-.=2.:.4--,-----' y RHR-SW-A & SW-2 CW-2 I I REC-SW-A 1 __ L ______ 7 I I CONTROL BUILDING BASEMENT HEAT B FLOODING WATER LEVEL SENSOR EXCHANGERS A LS C 751 SEAL WELL LEVEL I I I CONTROL SYSTEM I , 7 N I t v N I I I I RE 1 I ,- 3328 ' J N I t v N RE 332A I I I I I I I I I I I I 0 ~7 $,7 0 I I I I ____________ J I IL~ 1,17c IL~ r17B L~ A E-_J ~~~ ~-1-~ L ",&i J v/r-----..,,,..~~l=-~-i_c_~-~-~_L_~_~_A_L_L ______ ~---f---f---'-------------~-,-,-;,-,-,-,-,-,-J.,.-,.-,--,-,-,,-,-,-,-n ¢2 ////////////////// TO 24"37MV823F-37 INTAKE L - -i' STRUCTURE SEE SHT 1 THIS DWG, ZONE E-11 --===-DISCHARGE TO RIVER SEAL WELL .l <p 3 REVISIONS TO THIS DRAWING j cb 4 / REQUIRES A REVISION TO THE / WEST / CORRESPONDING ISOKEY. 24"CW-2 1-SW-104A-24 //////////////// I/ -- C.P. ~ ( )I( C.P. 1-SW-100B-24 24"SW-2 V L.,_ ______________________________________________________________ __,.,.,__+,j__, V 24"CW-2 1-SW-104B-24 AS BUILT 454003588 1-SW-1 OOA-24 1 I 2 I 3 I 4 24"SW-2 I 5 I I/ I/ YARD I/ BELOW MAT ,t-"Dc-_,G"'B"LD"G_---, 6 VERSIONS/REVISIONS BY NPPD NO. DESCRIPTION ORDER OFT DATE ENG AK 60 DR-2022-0001 DLR 3 9t22 JDMADDO A 61 DR 2022 0352 CC [NSTAUATIONl 5457885 DJB 8 08 2 L.JJENSE AM 62 DR 2022 0352 CC REMOVALl 5457885 DJB O 31 LJJENSE AN 6J DR-2022-0519 CC [NSTALLJ.TIONJ 5470720 OJB 1 21 JSOEOIC I 7 I 8 I 9 SIGNlflCANT NUhEIER GROUP 2 5 FLOW DIAGRAM CIRCULATING, SCREEN WASH & SERVICE WATER SYSTEMS COOPER NUCLEAR STATION 1 o I 11 DRAWN I DATE RAC 5/8/96 CHECl<ED I DATE APPROVED I DA.TE SEE~EDED STATUS: Release STATUS DATE: 11/21/2022 DS APPROVED: JSDEDIC VER: AN REV: 63 SIZE: F BURNS & ROE 0 m m r--- 0 0 ~ (J ""°""--,----'----------i C FIL.MED 2006 SH 3 12 A B C D E F G H J}}