1 to Updated Safety Analysis Report, Drawing 2016, Flow Diagram Fire Protection Service Bldgs & Yard, Sheet 1A
ML23129A352
Person / Time
Site: Cooper 
(DPR-046)
Issue date: 04/20/2023
From:
Nebraska Public Power District (NPPD)
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23129A261 List: ... further results
References
NLS2023022
Download: ML23129A352 (1)


Text

{{#Wiki_filter:A B C D E F G H j 1 2 3 4 5 6 '----'------7-------'-----s---------'------g-----'-----1-o ____ ..J..._ ____ 1 _1 ___ ___Jc.__ ____ 1_2 ___ ---,7 AIR RELEASE VALVE c~-----------l ] TO UNDER SW PUMP ROOM FP-468 M 1C FP-758 N f 1 O" FP-470' * ** FP-1 BCV 12* \_, l ,I FP-4:69 0 - FP-1003 * * - ~ FP-1004 ! ~ .~ FP-749, "c" BREAKER CABINET PS 6S1F I C-I FP-105 FP-106 FP.. -J4 FP-236' ** ~ FP-93 TO RIVER n (VENT) ~J FP-474 12* FP-14., ,tJ:-JO I *, 10" n n r \ FP-~08 I - FP-267 FP-268 N [7-==t~dP~IS~='--,] 52 STRAINER S183, .,FP-15 n FP-945 }- FP:-119 '---i;s:i.--'------1 H (VENT) n 1/2" FP-455 FP-121 FP-265

  • FP:-120 FP-944 FP-272 FP-270 FP-271 L>---

FP-266

  • r,,

FP-471 L-* 4--_,_--11:lf----L--W- (DRAIN) 12" FF:-J 9 N - FP-18' FP-16 FP-122 (VENT) 10" FROM SCREEN WASH PUMPS t-------i.* CONT. ON 2006 SH.1 ZONE H-2 SERVICE WATER PUMP ROOM I FP-476 I TO FLOOR __ FP-l-kl411-7_5 __ ~ _1_ ____ _j_F_P{l--:4)-7-3_, DRAIN ~HIOIIFP-123 FP-755 Pl 750 ///////,.- 8" ///////////////// FP-_22,(PI) 1-FP-102-8" FP-.2~(PI) 12" n FP-831 FP-539 FP-91 n FP-89': TO UNDER L_ __ s=w~ PUMP ROOM FP-90 FP-114 FP-115: n FP-832 n n FP-466 FP-465 ~ FP-463 ~ FP:-164 7 ,, FP-462 I/ , I/ 6 HEAD HOSE NOZZLE (SEE NOTE 11) (251 l (252l (253l (254 (255 (256 V l//t---YARD t ______ J PUMP CONTROL I i _INTERLOCK _ ~ ~----7 I Pl I 05 I FP-124 I FP-17RV, ' N I I I I I 2" (VENT) CW,:-~45 8" Ff:.-,21 FP-;:1?CV


"-----!Xl-.---f'_-J-a-......--'---11(

////// ///1 1" DRAIN LINE cw 846' II FIRE SYSTEM FLUSHING PUMP 15,000 GALLON FIRE SYSTEM FLUSHING TANK WT,:-187 FROM MEMBRANE PROCESS WATER TREATMENT r 1 WT-V-496

"I WT-CV-42CV 2"

.---=--~'--~] WT-:4]2 [ - ' N HV-321 C,...H

,FP-710 CONT. ON 2016 SH.2 ZONE G-14 CONT. ON B&R/NPPD 12*

FP-402(PI) FP-11 O(PI) 12* FP-403(PI) DWG. 2016 SH.2


,11:f---,---------"=------------------------------(:><J---..L..---'--------[)<J--------'=----_._----'----l>(l-------------------,-,------j'------------------------'-1--'-'FP'---1'-'0'-'1---'1-"2-" ________________________ _,_,

WNEK-6 ~ 1-FP-141-6" FP-.4q(PI) FP-287 f-',....!..!---'.:c..!...--"---!><l-..:......:.---,O HT-1 FP-80(PI): '

    • ,'FP-39(PI)

FP-79(PI) 1-FP-112-6" (NEAR INTAKE STRUCTURE) ---t---- -. />_-- - - -HE-A-TING -BOILER ROOM -- - -T-- -~ FP-129 i15,.. ! .----11:lf----------,,-JI -~ r:i t-ow DIESEL GENERATOR BLDG. ' 0 I (L IL I - ' N -I 0 -I (L IL I - {p]\ _J; FP-388 I B NB I FP-387 '('.5/ I FP-128 ,l u N I -~ ( FP-385 * ~ RETARD [ ( CHAMBER FP. 383 I I FP;:J84 ,t, o:;t~,e-Ji----{_~-:_~ DVA-2 1 l~ 1 TO ANN 1 { 1 FP-126 / L .~..f---... FP-4 B-4 l __ /sw\ 1 \P-125 >--~] N I zo D z'- <I'."' o' f-8:: I I 0, \_2.,J FAN ROOM I ~ I 8:: I FP-24(PI~ '. FP-294 O (OUTSIDE WATER HT-2 TREATMENT BLDG.) N I... 0 I 8:: I - 1 ~IND WATER TREATMENT AREA FLANGE ~ &9 (PS\ __J I I I I FP-280~y [~I--, (VENT) FP-281 PT 651 FP-285 (VENT) [ c* FP-286: Pl 656 FP-283 (VENT) [ C FP-284, 1-FP-106-1 Q" FP-378 ROOF DRAINS I I


t-] -

WE-~-~-S-HOP - -F-P---38-_1 - ~7 FP-380 X 1=----_J----~v~t-J I FP 382 I TO ANN FP-3/D-3 n ---------< =* ~ .... ~ FP-~20 I 1-----':::---* ll I uy I

s

~ I ~~ /4\ ~~ \.3.,J r::'~ C~ FP-377 -~ [... FP-374 ~- FP-376 ~ RETARD CHAMBER I I FP-42cv: 1. L_ I 1 I FP;-372 r,, I FP-,:1-l(PI) I I 8:: I -,. ,,FP-25(PI) FP-293 0 \,,. HT-3 (NEAR SEAL WELL) L __ _ ~) _____ --+- __,__ ____ L _________ B_o_ILE~Y~~~~ F;~;;~K-LE_R ____ _J _______ J_ ________________________________________________ F_P_-_;:_:~N~ --+-- _ -*-~1 ~coNT. ON FP-~3:>17f-3""1-~-~J ~ TO ANN - - -+/sw\*swf.t-l('. FP-238 FP-3/D-4 ~ - 1-FP-107-6" FP-49(PI) t--t-,-C><J'-'-----1 I 1 CONT. ON 2016 SH.1 ZONE A-3 CONT. ON 2016 SH.2 ZONE K 2 CONT. ON 2016 SH.1 ZONE A-3 / AUGMENTED RADWASTE BLDG.----.(, /, I/ / REACTOR BLDG.-----t/ CONT. ON 2016 SH.1C ZONE C-12 CONT. ON 12.. FP-1 FP-37(PI) 2016 SH.1 B --=....:...:---'----tx:I'-'--------. ZONE F-10 I/ / t; V / V V FP-64:(PI) 'J CONT. ON 2016 SH.1 ZONE A-9 CONT. ON 2016 SH.1 ZONE E-12 CONT. ON 2016 SH.1 ZONE G-12 I DWG 2835-68 WELD SHOP AREA SPRINKLER SYSTEM #3 1-FP-108-1 Q" 1-FP-113-12" I I I FP-26(PI) : : FP-50(PI) I FP-56(PI) ~---------------------~ N -I - 0 I

a.

IL I - HT-4 FP-292 0 '7 FP-27(PI) I 1 I 8:: I - CONT. ON FP-'.!3j(PI) 1-FP-101-12" FP-J1(PI) FP-.3~(PI) 2016 SH.1 B --+-+-----iX.t--'----------.---------------,------'----r-------,--'--'-'-='---'c.e....----,_tx:1:.......;--_.---iX.t-'-------------,-------------------,,-.---------------------------'L--{_:::,-..._, ZONE F-9 12" FP-1 3 4 FP-35(PI) ' FP-906(PI) ' FP-289 0 HT-8 (NEAR OFFICE BLDG.) CONT. ON 2016 SH.3 ZONE E-3 NOTES:

1.

UNLESS OTHERWISE SHOWN, ALL PIPING ON THIS DIAGRAM IS DESIGNATED "FP-1 ".

2.

ALL PIPING SYSTEM FABRICATION SHALL BE PER THE CLASSIFICATION SHOWN ON THE MATERIAL SPECIFICATION SHEETS AND SPECIFICATION E-69-4.

3.

ALL VALVES IN FP-1 SHALL BE 175# F.U. SPECIAL.

4.

SUFFIX (Pl) DESIGNATES POST INDICATOR VALVE.

5.

AUTOMATIC SPRINKLER CORPORATION OF AMERICA ABREVIATED AS ASCOA WHEN IDENTIFYING SPRINKLER AND SPRAY SYSTEMS DRAWING NUMBERS.

6.

REACTOR BUILDING AND CONTROL BUILDING FIRE PROTECTION PIPING SYSTEM AND SPRINKLERS ARE SUPPORTED FOR CLASS IS RESTRAINED CRITERIA. INTAKE STRUCTURE FIRE PROTECTION PIPING SYSTEMS ARE SUPPORTED FOR BARGE IMPACT CRITERIA. 5 6 CONT. ON 2016 SH.3 ZONE E-6

7.

ALL VALVE NUMBERS IN PARENTHESIS( ) ARE NUMBERS TO BE USED IN OPERATING PROCEDURES. THESE NUMBERS ARE ASSIGNED BY NPPD AND WILL NOT BE SHOWN ON PIPING DRAWINGS.

8.

VALVES ARE UNDERWRITERS APPROVED.

9. 6 'S WHERE SHOWN WITH NUMBERS REPRESENT POINTS OF CON-NECTION TO EXISTING SYSTEMS E-73-58 SPECIFICATION DEFINES WORK FROM THIS POINT.
10. ALL VALVES ARE IN THE FIRE PROTECTION (FP) SYSTEM UNLESS DESIGNATED OTHERWISE.
11. ALL VALVES ON THE 6 HEADED HOSE NOZZLE ARE CLOSED.
12. 6 INDICATES ONE OR MORE SPRINKLER HEADS IN LINE.
13. WHERE LINES ARE INTERCONNECTED AND CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROXIMATE ONLY.
14. '\J1 HEAT TRACE 7

8 FP-_3q(PI) FP-291 FP-_29_(PI) HT-5 O 1 FP 145 6" SIGNIFICANT NUIIIBER GROUP VERSIONS/REVISIONS BY N.P.P.D. NO. DESCRIPTION DFT DATE ENG AB 09 DR-2016-0002 DJB 4 20 1 EWERN 9 FP-467 FP-_28,(PI) HT-6 O 1 FP 146 6" (NEAR SEWAGE TREATMENT CONTROL BLDG.) REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY. DRAWN DATE RGA 6-7-95 4 CHEa<ED DATE FLOW DIAGRAM KG 5-28-99 APPROVED DOK DATE 6-3-99 AS BUILT 454243820 STATUS: Release STATUS DATE: 04/20/2016 DS APPROVED: NEWERNE VER: AB REV: 09 SIZE: F BURNS & ROE <O <O g - 0 0 FIRE PROTECTION SERVICE BLDG'S & YARD COOPER NUCLEAR STATION ~u 1---.----~---------i C FILMED 2016 SH. 1A ~ 10 1 1 12 A B C D E F G H j}}