{{#Wiki_filter:A B C D E F G H j 1 2 3 4 5 6 '----'------7-------'-----s---------'------g-----'-----1-o ____ ..J..._ ____ 1 _1 ___ ___Jc.__ ____ 1_2 ___ ---,7 SBNl-103 1 1/2" FLG'D FLUSHING CONNECTION 1 1/2" FLG'D FLUSHING CONNECTION fcs "' PC-417 fcs "' PC-418 [-'1------i PC-416 VENT n 1/2" PC-520 ~ ~ I I fcs@ [-'1--------i PC-555 PC-419 PC-415 PC-49 [-'1------i PC-556 PC-420 -- - ----(X]-- - -- SEE DWG. 2026 SH. 1, ZONE E-5 c'--7 L _ -I AUTO ISOLATION I SYSTEM IR~SI IR~SI r---------1--------r I ~~ I MO _J4:l:6 MO 1 J05 1 J06 TEST CONN. ~o ~g Jes _J C n 1/2"PC-524 1/2"PC-525 SBNl-16CV 1 "PC-1305MV 1 "PC-1306MV SEE DWG. 2022, SH. 1, ZONE E-7 VENT n 1/2" PC-523 SBNl-14CV SBNl-101 SEE DWG. 2022 SH. 1, ZONE F-7 PC-483 PC-482 ~f---- 24" --~Tf---- PC-238AV PC-232MV c'--7 L _ -I AUTO ISOLATION I SYSTEM U) - z U) IR~SI IR~SI r---------1--------r TEST CONN. I ~~ I MO _J4:l:6 MO ~o ~g Jes _J C 1 J0J 1J04 1.. 1 "PC-1303MV 1 "PC-1304MV ~ PC-485 PC-484 ~f--___ 24"PV-L __ l}~-~ PC-237AV PC-233MV n 1/2"PC-521 1/2"PC-522 U) -I z U) I 5'. X-205 X-40A X-25 X-215 11/2"SBNl-1 S PC-58 DRYWELL SUPPRESSION CHAMBER "' cs! "' cs! 20" X-26 SEE DWG. 2022 SH 1 ZONE C-2 2"PC-510 1/2" PC-508 1/2" PC-509 ~ LJ MO 24" ~ ---~ T f-- --- _y_ 1 u PC-39 PC-306MV Q-1 AUTO ISOLATION I SYSTEM _.,..,o r 1 "FLG'D FLUSHING I 1 -c CONNECTION MO _JY:t~ 1310 PC-410 L.__,1_"P:..Ve..:-:..1c,S,._ __.,..,-0c ____ _L_ __ ---'l=f-------' 1"PC-1310MV ~ _f ~-426 PC-63 SEE DWG. 2026, <---- ----l><J-- - ZONE E -8 SH. 1 SPACER PLATE X-400 X-398 U)
- u N_
I ::> U) z_ "' w U) U) N I I 0:: TEST CONN. 1/2" PC-515 r----/ ~~~~E~SOLATION Q i Q I ~~ I 1/2"PC-514 MO _J~6 MO 1311 1312 OC AC 1"PC-1311MV 1"PC-1312MV PC-435 SBNl-2 SBNI-1 PC-442 1 O"RH-2 SEE DWG. 2040, SH. 2 -~ - --- ---1 ZONE A-5 c'---i l-- -1 AUTO ISOLATION I SYSTEM Q Q r-------1----------r I ~~ I I l'l 1/2" PC-517 MO _J~6 MO 1302 1301 AC DC VENT "' 1/2" PC-518 11/2" - SBNI-17CV 1 1/2"PC-406 VENT "' 1/2" PC-519 \_ 1 1/2" FLG'D FLUSHING CONNECTION ND r I CONT ON 2022, SH. 1 ZONE D-9 CONT ON 2010 SH.2 ZONE J-9 T I _ _J SBNI-SOV-50 1" . [c-J<:t--.,.f-O---,.---D----'-----J>'::J-------,------l>':J---(::J--'-r-----1/1---'-r----------l 1/2" PC-516 X-220 16" X-206 I PC-59 1 "PC-1302MV U) ~ -I ::> z U) "' w U) U) PC-400 " I I 0:: 6"RH-4 ----r X-211 PC-486 SEE DWG. 2040, SH. 2 ZONE D-4 ~ 1 "PC-1301 MV SBNl-15CV SBNl-102 11/2"PC-407 ~ CONT ON 2022, SH. 1 ZONE D-9 1 N I 24" TO STANDBY GAS TREATMENT UNITS PC-203 - PC-209 ,------- :tl--,-----.--------{:l( -------7 I I I I ~ ( PC-204 PC-14RV I PC-202 CONT ON DWG 2027 SH 2 2"PC-187 ZONE G-10 PC-16CV SURGE CHAMBER 1' I I I I I PC-15RV I I SUTORBILT COMPRESSOR 1-A I PC-210 2"PC-212 PC-17CV SURGE CHAMBER SUTORBILT COMPRESSOR 1-B L _ - -- - I I I I
,,----,,---J 2"
[ NOTES: 1/2" PC-186 {, CONT ON ZONE E-8 [ 1/2" 2"PC-211 PC-4 71 PC-4 72 r----------<lrl----------,[><]----, PC-499 ~ --- ~ 24" -_ i _I~-., ---~Tf-----PURGE & VENT LINE __
- 1.
UNLESS OTHERWISE INDICATED ALL PRESSURE AND/OR FLOW INSTRUMENT ROOT VALVES SHALL BE 3/4" ROOT VALVES SHALL BE 3/4"V226X. IA-Pl-100 PCV IA-PRV-PRV101 IA-Pl-101 IA-547 L.C. SEE I 1 TO Pl -20 DPT-20 DWG. 2027, SH. 2 ZONE F-9 IA-545 CONT. ON 2022 SH 1 r--~-~-~---,--~-~--r--~---l.--4--r----.i:kl--~....L.-..J....-,-__..._....1.._ ZONE F-9 TO N2 N2 NOTE: N2 N2 N2 N2 N2 HCVS MECHANICAL REMOTE OPERATING STATION CYLINDER STORAGE RACK (9 BOTTLES REQ'D) (OPERATE 9 AT A TIME) N2 GENERAL NOTES ON THIS DRAWING DO NOT APPLY TO THIS STORAGE RACK. N2 IA-550 IA-PCV-100 IA-551 L.C. PC-AOV-237AV IA-543 CONT. ON 2022 SH 1 ,._-+<I-~- ZONE F-11 TO L.C. PC-AOV-A032 IA-544 L.C. INTERNAL RELIEF SBNI-Pl-11 (SBNI-Pl-21) PI SBNI-PI-12 PI (SBNI-Pl-22) 1.. 1/2"o.D. S.S. TUBING~~ REACTOR BLDG. WALL TRAIN "A" "'-::::::l S:~ I PC-432 r-------------------7 SBNI-PI-1 PI SBNl-15 SBNl-5 L_ /'1 I TRAIN "A" V CONTROL STATION I IN SOUTH VESTIBULE l SBNl-1 CV __________ _J B31.1.0 ASME III, CL2 SBNl-3, SBNl-1, SEISMIC IS SEISMIC IS VALVES NORMALLY CLOSED STORAGE, NORMALLY OPEN OPERATION. FOR FOR I H---.-----.---.----.---,---.----,---,--,--.---,--.--iM-L----{)l<J-...L.--L.-(::HaI----C--~ SBNI-PCV-PRV1 (SBNI-PCV-PRV2) SBNl-1 (SBNI-2) SBNl-11 (SBNI-12) I \ \ SBNl-4 f-1-J PC-558 PC-434 2"PC-511 fcs"@ l --, SEE DWG. 2027, l'J I SH. 2, ZONE H-7 S:~ I PC-431 f-1-J 1/2" PC-512 PC-557 PC-433 1/2" PC-513 PC-305MV LJ TEST CONN. 1 "PV-1 S Q-1 AUTO ISOLATION I SYSTEM I ~~ MO _JY:t~ 1308 DC 1 "PC-1308MV ~ 2 NC SPACER PLATE I 5'. - PC-489 U) -I -z U) r------------------------------1 SBNI-Pl-2 SBNl-10 L SBNl-1 RV Iv TRAIN "B" CONTROL STATION SBNl-6 : TO N2 SYSTEM >--~ 1 -,, CONT ON 2022, I ZONE A-9 SBNI-PCV-PRV3 SH. 1 I I I SBNI-FI-2 I I I I (PRIMARY N 2 SOURCE) l SBNl-3CV
~
B31.1.0 ASME III, CL2 SBNl-3, SBNl-1, SEISMIC IS SEISMIC IS U) REACTOR BLDG. WALL J. z l" - TRAIN "B" SBNl-8 U) I u U) w U)
- 2.
ALL TEMPERATURE TEST AND PROTECTING WELL PENETRATIONS SHALL BE 1" NPT UNLESS OTHERWISE NOTED.
- 3.
MATERIAL DESIGNATION -1S STAINLESS STEEL.
- 4.
LOW POINT DRAINS WITH VALVES SHALL BE PIPED TO RHR PUMP ROOMS AND ARE NOT SHOWN.
- 5.
FOR PIPING SPECIFICATIONS AND SEISMIC QUALIFICATION SEE SPECIFICATION E-73-58 AND DC89-272.
- 6.
PART NO'S ARE INTERCHANGED ON FOLLOWING VALVES: 1303MV INTERCHANGED WITH 1305MV 1306MV INTERCHANGED WITH 1304MV POWER & CONTROLS ASSIGNMENTS REMAIN UNCHANGED.
- 7.
REFERENCE DWGS. BECKMAN 13370, BENDIX 203636R, B&R IL-E-70-3 SH.111 FOR HYDROGEN SAMPLE SYSTEM.
- 8.
INSTRUMENT. SAMPLE. TEST. DRAIN AND VENT LINES ARE NOT ALWAYS THE SAME CLASS AS THE MAIN LINE AND THESE BOUNDARIES ARE TOO NUMEROUS TO IDENTIFY IN THIS MANNER (SEE ISi PROGRAM BOUNDRY DESCRIPTIONS FOR DETAILS).
- 9.
CB IS PRIMARY CONTAINMENT BOUNDRY.
- 10.
WHERE LINES ARE INTERCONNECTED AND CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROXIMATE ONLY. DRAWN DATE AS BUILT 454035514 STATUS: Release STATUS DATE: 05/14/2018 DS APPROVED: KASCHIZ VER: AE REV: 30 SIZE: F N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 PRESSURE REGULATOR ASSEMBLY FLEXIBLE HOSE '-'-_, ~~~-]-----!----------------------------------------' SIGNIFICANT NUIIIBER 1 PORTABLE CYLINDER STORAGE (14 RACKS REQ'D) (OPERATE 1 AT A TIME) 2 RACK 3 (1 REQUIRED FOR OPERATION) (2 SPARE) 4 ROUTING CONFIGURATIONS (1 REQUIRED IF PRIMARY N 2 UNAVAILABLE) 5 SBNl-9 6 7 8 FOR PREVIOUS REVISIONS SEE SUPERSEDED CARDS. VERSIONS/REVISIONS BY N.P.P.D. NO. DESCRIPTION AB 28 DR-2015-0086 AD 29 DR-2017-0001 /lE. 30 DR-2018-0001 9 DFT DATE ENG DJB 10 22 1 KKKUKE DJB 8 15 1 MTMCC.AN DJB 5 14 1 KASCHIZ GROUP 4 FLOW DIAGRAM STAND BY NITROGEN !NJ ECTION SYSTEM COOPER NUCLEAR STATION 10 1 1 CHEO<ED DATE APPROVED DATE SEE ~~EDED BURNS & ROE <Xl r--- 0 0 ~u f---r---~---------i C FILMED 2084 12 A B C D E F G H j}}