1 to Updated Safety Analysis Report, Drawing 2016, Sheet 1C, Flow Diagram Fire Protection Reactor Building
ML23129A332
Person / Time
Site: Cooper 
(DPR-046)
Issue date: 04/20/2023
From:
Nebraska Public Power District (NPPD)
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23129A261 List: ... further results
References
NLS2023022
Download: ML23129A332 (1)


Text

{{#Wiki_filter:A B C D E F G H j 1 2 3 4 5 6 '----'------7-------'-----s---------'------g-----'-----1-o ____ ..J..._ ____ 1 _1 ___ ___Jc.__ ____ 1_2 ___ ---,7 //////////// CONT. ON 2016 SH.1 B ZONE D-11 CONTROLLED CO RRIDOR 1 / / / / / / / / / / / / / / / / 3/4" FP-223 oAo ,~, a I. - 0 0 .J w G! 2 1/2" FP-341 HV-45 * * (VENT) 3/4" FP-674 (NOTE 13) Pl 75 TO HEPA PRE FILTER B SPRAY NOZZLES 4" 3/4" FP-222 ,~, ,~, (VENT) TO ANN FP-3/B-4 I I TO ANN I I FP-3/E-2 SUPROTEX fLs\ I t 1/4"FP-429 ~J T I I ~ rei'\ DELUGE 1 - VALVE 1 FP-DVA-23 -] 1 1/4" FP-78CV I 1, I I 1,_. >------,L- - ~ 1,, u J. FP-427,-'---a Tf-----L'J 2 1/2" FP-431 3"FP-425

  • ~..

I, TO ANN ____ J FP-4/B-6 -~ REACTOR BLDG. SBG TREATMENT AREA CARBON BED FIRE PROTECTION SYSTEM N0.23 \::./~ 3"FP-454 2 1/2"FP-340 HV-44 *

  • 2 1/2" FP-481 HV-58 *
  • 3/4"FP-224 181 (VENT) 3/4" FP-675 (NOTE 13) 2"FDN-36 2" FDN fLs\ T 2 1/2"FP-343 HV-46 *
  • 2 1/2"FP-342 HV-41
  • v21/2"(TYP.)

TO HEPA PRE FILTER A SPRAY NOZZLES SUPROTEX DELUGE VALVE - 7 C7 (PI'\ *'

  • 11 " FP-428

'f.!3/.,. 14 FP-DVA-22 1 'r--------i 1 ' I 1 1/4" FP-77CV [- 1/2" I ,---1 ---------< ---L,1 ~P-426 l,- - c---'------1." 3"FP-424 2 1/2" FP-430 ,I ~4 * --~ TO ANN FP-4/A-6 REACTOR BLDG. SBG TREATMENT AREA CARBON BED FIRE PROTECTION SYSTEM N0.22 4" FUTURE CONNECTION 4"FP-483 * ** 2 1/2" FP-336 HV-42

  • 2 1/2"FP-338 HV-40 *,v 2 1/2" (TYP.)

2" FDN CONT. ON 2038 ZONE C-9 /- - ""T 2"FDN-35 2 1/2"FP-337 2 1/2"FP-339 HV-43 *

  • 2 1/2"FP-479 HV-56 *.*

1 1/2" FP-232 HV-39 *.,V 2 1/2" (TYP.) 3/4" FP-225 ,A, 4" 1 "FP-409 (VENT) 3/4" FP-676 (NOTE 13) '7 '7 '7 8 FP-PRV1 _f ~\__ __ L__-----,---,--------;------li. Pl 09 ,- TO ANN I FP-3/E-1 0 I. - 0 0 - .J w .J / / / / / 2 1 "FP-423 2"FP-229 'i, z °' I oro01 '"' -~ >-ow I 2 Nz 0 ol U N -{, 1"FP-410 '

  • I 1/2" FP-412_~
---c (DRY1)

/ Pl \ 1/4" FP-44CV \.V TO ANN -~-,__...L._-, FP-3/F-1 FP-PRV2

  • FP-6CV 1 : SUPROTEX l 1/4" FP-769 9

1/2" Ff'-411 "r I DELUGE 'l------1,lC --~"""1 VALVE ,....__LSI -'""'Pl Fp DVA 6 r IS\ r Pl\ FP-18RV 21/2" 1**' I \ 6 / \ 6A / FP-15CV1"r 1 ~ ~ c--lv~.,_ ___ .J_ ___ --L __ _.l-- 1/4" FP-413 ~J u ~ ~ ~ M.G. SET DRY PREACTION ~ I 2 1/2" FP-548 11," FP-408 ' (PI'\ J-'I 09 I c* ~ 1/4" FP-406 ~ TO ALARM y (BELL) 1/2" FP-422 < ~ I LJ -~ -~-~~ c *"' ' I 1"-" FP-405 1/4" FP-407 r'- ,A, T7----l,C~.ll-,----'--~,a J 1 1**' 1 RETARD TO ANN FP-4CV : " 2"FP-231 CHAMBER FP-4/F-1 L __ _J I ~ 'i' L - -r~1~1), 0.t-*: 2 1/2" FP-230 u SPRINKLER SYSTEM N0.6 1 Y," FP-228 HV-63

  • CONT. ON

' ~ OIL PUMPS & MOTORS FOR M.G. 3/4" FP-226 IL'!t.l (VEN°T) 3/4" FP-677 3 3"FP-227 x-----,L 2010 SH.2 ZONE A-9 N SET SPRINKLER SYSTEM N0.4 i TO ANN '-eJ FP-4/F-1 4 0 I <O r-- O> .J w .J NOTES:

1.

UNLESS OTHERWISE SHOWN, ALL PIPING ON THIS DIAGRAM IS DESIGNATED "FP-1 ".

2.

ALL PIPING SYSTEM FABRICATION SHALL BE PER THE CLASSIFICATION SHOWN ON THE MATERIAL SPECIFICATION SHEETS AND SPECIFICATION E-69-4.

3.

ALL VALVES IN FP-1 SHALL BE 175# F.U. SPECIAL.

4.

SUFFIX (Pl) DESIGNATES POST INDICATOR VALVE,

5.

AUTOMATIC SPRINKLER CORPORATION OF AMERICA ABREVIATED AS ASCOA WHEN IDENTIFYING SPRINKLER AND SPRAY SYSTEMS DRAWING NUMBERS.

6.

REACTOR BUILDING AND CONTROL BUILDING FIRE PROTECTION PIPING SYSTEM AND SPRINKLERS ARE SUPPORTED FOR CLASS IS RESTRAINED CRITERIA. INTAKE STRUCTURE FIRE PROTECTION PIPING SYSTEMS ARE SUPPORTED FOR BARGE IMPACT CRITERIA. 5 6 I

  • oc, U)

O> .J w .J 1-FP-134-4" 2 1/2" FP-335 HV-37

  • 4*

2 1/2" FP-334 HV-34 *

  • 6"FP-70 CABLE TRAY ~K-1----C-]--,

SPRINKLERS ' ' ~ 3"FP-528 k---n' rsw\ 1 "FP-552 7\ 7, 1 1/2" FP-546 y I I IF?\ \:;,I /p1\ 'f 1 3/4" FP-532 -..:.:7 z~ I Zu-, <C I 0 o._ TO ANN FP-5/B-6 f-- "- 1-FP-133-4" REACTOR BLDG. 903' N.E. & CABLE TRAY SPRINKLER SYSTEM N0.35 REACTOR BUILDING (VENT) 3/4" FP-543 2 1/2"FP-482 HV-59 *

  • 2"FDN-34,
  • 2 1/2"FP-480 HV-57 *
  • 1 "FP-542 f,s\ ___ TO ANN mrafPI'\Pl..t------l)(l*-\,:-,2?,/

FP-5/D1 " 0991 V4" FP-529 ~1/4" FP-518 7' f---j~-[ L 1 1/2" FP-512 ')t----,~hs~wr,+--~ TO ANN ~ FP-5/C1 M.G. OIL COOLER WET SPRINKLER SYSTEM N0.27 1-FP-132-4" 2" FDN 1-FP-131-4" 4" 4"FP-551 ~ I 7 I 1 "FP-507 L____.,1--J O> .J w (DRAIN) 2 1/2" FP-549 .J T HV-62

7.

ALL VALVE NUMBERS IN PARENTHESIS( ) ARE NUMBERS TO BE USED IN OPERATING PROCEDURES. THESE NUMBERS ARE ASSIGNED BY NPPD AND WILL NOT BE SHOWN ON PIPING DRAWINGS.

8.

VALVES ARE UNDERWRITERS APPROVED.

9. D,_ 'S WHERE SHOWN WITH NUMBERS REPRESENT POINTS OF CON-NECTION TO EXISTING SYSTEMS E-73-58 SPECIFICATION DEFINES WORK FROM THIS POINT.
10. ALL VALVES ARE IN THE FIRE PROTECTION (FP) SYSTEM UNLESS DESIGNATED OTHERWISE.
11. ?5, INDICATES ONE OR MORE SPRINKLER HEAD IN LINE.
12. WHERE LINES ARE INTERCONNECTED AND CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROXIMATE ONLY.
13. NITROGEN MAY BE PRESENT PER CED 1998-060.

(REF. SER 98-003, CR 2003-2282 & EC 5174833). 2 1/2"FP-330 HV-38 *

  • 4" 2 1/2" FP-328 HV-36 *.*

2 1/2" FP-332 HV-35 *,

  • 4"FP-66 4"

4" ' <O I 0 O> .J w .J 6" 21/2" FP-331 HV-33 * * ~ 6" 2 1/2"FP-329 HV-32 *

  • 6" 2 1/2"FP-333 HV-31 *
  • 6" 6"FP-69

' <O ' 00 / I/ / I/ F//////// I/ ' <O / I I/ OC) OC) I/ / .J / w .J / / I/ I 1 1/2 FP-233 (DRAIN) 10" CONT. ON i-----------'-"'------1 f--+-f-------,2016 SH.1 A ZONE G-6 6"FP-68 6"FP-65 00 lF z 0 "- N 2"FDN-37 L.C. ' <O I. - 00 OC) 2"FDN-33 .J w .J L.C. / / / / / / / / / / / REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY. I 0 O> .J w Vl - w o._ - o._ Vl - I f-- ~ I/ I/ V I/ / / I/ V / I/ V I/ I/ / I/ V / I/ / / / / / LJ YARD YARD AS BUILT 454243822 STATUS: Release

  • THIS DRAWING GENERATED BY NPPD STATUS DATE: 04/02/2018 DS APPROVED: LJJENSE VER: AB REV: 04 SIZE: F FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.

VERSIONS/REVISIONS BY N.P.P.D. NO. DESCRlPTlON DFT DATE ENG AB 04 DR-2015-057B DJB 4 O 1 LJJENSE 7 8 9 SIGNIFICANT NUIIIBER GROUP 4 FLOW DIAGRAM FIRE PROTECTION REACTOR BUILDING COOPER NUCLEAR STATION 10 1 1 DRAWN DATE RGA 6-7-95

  • CHEO<ED DATE BURNS & ROE 0

KG 4-8-99 O> 0 co APPROVED DATE 0 DDK 5-25-99 0 ~u FILMED C 2016 SH 1 C 0 ~ 12 A B C D E F G H j}}