1 to Updated Safety Analysis Report, Drawing 2034, Flow Diagram Plant Make Up Water Treatment System
ML23129A328
Person / Time
Site: Cooper 
(DPR-046)
Issue date: 04/20/2023
From:
Nebraska Public Power District (NPPD)
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23129A261 List: ... further results
References
NLS2023022
Download: ML23129A328 (1)


Text

A B

C D

E F

G H

J 1

ABANDONED IN PLACE (SEE NOTE 9)

(198)

(201)

(195)

TO CONTROLS (199)

(200)

DRAIN (197)

DRAIN 6" WELL WATER MAJN REFER TO CC 5350257 WELL #1 WELL #2 (203)

(524)

(204)

{525)

SEGREGATED FLOOR DRAIN 1

3"CF (ALLOY 20)

AIR RELIEF VALVE (18RV) 2" 10 (10CV)

AIR RELIEF VALVE

{19RV)

(11CV) 2 1-WT-101 (13CV)

(12CV) 19 1/2" 161 (193)

(194) u FUTURE EXPANSION 12 13 17 16 (188) 161 (191)161 (20RV) 1/2" HYDRO-PNEUMATIC TANK SEE NOTE 9

-20 N

519 527 526 518 517 6"WD-1 520 N

{208)

ACCESS PIT SUMP NEUTRALIZING SUMP REMOTE PLUG (TYP)

I I

l_

2 I

I J

521 522 0 523

{209) 3 2WD-1 RIVER TO MEMBRANE PROCESS WATER TREATMENT SYSTEM WT-477 w

13 WT-513 WT-53~!

2016 SH 2 ZONE F-10 4

4"WD-1 WT -530 WT -400

~~~~__,f><l r'--.---,f-~

.... -~---jHOSE CONNECTION YARD 529 528 WATER TREATMENT L--- 6" WEU. WATER MAIN I

ABANDONED IN PLACE u

PER CC 5350257 n

REMOVABLE SPOOL TO DRAINAGE 2"

DITCH A

3"DR-6 MAIN SUMP A

,a~ DR-6 TO POND 3

4 5

5 6

c__.J...._ ____ 7 ____

__j_ ____ s ____ __,_ ____

9 ____ -'-____

1 o ____ _,__ ____

11 ____

..J..._ ____

1_2 ___ ---,7 TO CONTROLS ABANDONED IN PLACE (SEE NOTE 9)

(198)

(201)

(199)

(200)

DRAIN (195)

(197)

DRAIN 6" WELL WATER MAJN REFER TO CC 5350257 (12CV)

(193)

(194)

N 1-WT-101 (13CV)

(188) 161 (191)161 (20RV) 1/2" HYDRO-PNEUMATIC TANK SEE NOTE 9

-20 527 526 6"WD-1 N

519 520 u

FUTURE EXPANSION 521 522 TO MEMBRANE PROCESS WATER TREATMENT SYSTEM w

WT-477 WT-513 RIVER BLIND FLANGE AND WT-531 REPLACED w/ WYE CONNECTION w/ 2 VALVES,-

I I

I

/

2016 SH 2 ZONE F-10

\

,.,T

\

4"WD-1

\ WT~3~f-\-l"---WT

-4f-oo_~ __

,HOSE

\

\

CONNECTION I

\

YARD\

WATER

\

529

\

TREATMENT

\

I I

\

I

\'

I 528 I

I I

\

I L--- 6" WEU. WATER MAlN

\ I I;

}

I ABANDONED IN PLACE u

PER CC 5350257 n

/

/

/

/

/

/

/

/

/

/

/

//\_

HOSES MAY BE ATTACHED AS NEEDED PER 2.2.57 AND AN APPLICABLE W.O.

523 WELL #1 WELL #2 (203)

{524)

(204)

{525)

AIR RELIEF VALVE

{18RV) 2" 10 (10CV)

AIR RELIEF VALVE

{19RV)

(11CV) 12 13 17 16 518 517

{208)

ACCESS PIT SUMP ALTERNATE WELL WATER SUPPLY SYSTEM SUPPLY TO WATER TREATMENT SYSTEM (REFERENCE PROCEDURE 2.2.57) r=, FILTER

,------1 y

1 I

,L 2"V126S-195 y

2 DW 1S SUMP 6

VENT 30,000 GALLON DEMINERALIZED WATER STORAGE TANK

' I I

L __ l I

,-J..,

B~DW-1S TO TRANSFER PUMPS SEE DWG 2013 ZONE 8-9

{209)

TO DRAINAGE 2"

DITCH

_/

\

7

~

~ (295)

{192)

/LG\

~

'(296)

(280)

,

  • 281 LT J297) 702 (282)

/LG\

(293) *

~

1298)

{294) 193

'7 194 REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY.

8

~

LC LI LS

_J 702 702

.;'585 t

PUMP A

TRIP LS 70"}

I 0 "

w LS 702tj I

m w

I w

LS 702':

VERSIONS/REVISIONS BY NPPD NO.

DESCRIPTION ORDER DFT DATE ENG AD 1 DR-2020-0296 5350257 DLR B 4 21 JEDAUEL AE 2 DR-2020-0296 5350257 DLR 12 22 21 JEDAUEL 9

7 I

J I

I I

I

~

I I

I I

_J SIGNlFICANT NUWBER GROUP 2

NOTES:

1. DELETED
2. HEAVY LINES INDICATE EQUIPMENT & PIPING FURNISHED AND INSTALLED UNDER CONTRACT E69-4.
3. LIGHT LINES INDICATE EQUIPMENT & PIPING FURNISHED BY OTHERS AND INSTALLED UNDER CONTRACT E69-4.
4. UNLESS OTHERWISE INDICATED ALL PRESSURE AND FLOW INSTRUMENT ROOT VALVES SHALL BE 3/4. LINES UP TO AND INCLUDING ROOT VALVES SHALL BE FURNISHED AND INSTALLED UNDER CONTRACT E69-4.
5. DELETED
6. DELETED
7. AT SAMPLING POINTS SP-32 & SP-52, CONNECTIONS, PROBES AND ROOT VALVES SHALL BE FURNISHED AND INSTALLED UNDER CONTRACT E69-4.

PROBES SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH CONTRACT PARAGRAPH 3.4.2 AND DWG. SP-07211, FIGURE NUMBER />S NOTED. ALL OTHER SAMPLING POINTS ARE SUPPLIED BY DEGREMONT-COTTRELL AS INDICATED ON D.C. DWGS. CONTINUATION OF SAMPLE PIPING BY E70-3.

8. WHERE LINES INTERCONNECT AND ARE CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROXIMATE ONLY.
9. HYDRA-PNEUMATIC PRESSURE MAINTENANCE SYSTEM NO LONGER USED AND ABANDONED IN PLACE.

NOTE: ALL ITEMS MARKED THUS 0 ARE "AS BUILT" ITEMS AND ARE NOT SHOWN ON PIPING DRAWINGS.

AS BUILT 454003627 DRAWN HFY 5

CHECKED DAlE 06/28/02

"'n:

STATUS: Release STATUS DATE: 12/22/2021 OS APPROVED: JEDAUEL VER: AE REV: 72 SIZE: F COOPER NUCLEAR STATION FLOW DIAGRAM PLANT MAKE UP WATER TREATMENT SYSTEM N'PROVED DAlE SEE SUPERSEDED CARD5 Fll.MED BURNS & ROE a,

0 0 u 2034 10 1 1 12 A

B C

D E

F G