{{#Wiki_filter:A B C D E F G H J 1 2 3 4 5 6 '--.,___ ____ 7 ____ __j_ ____ s ____ __,_ ____ 9 ____ -'-____ 1 o ____ ---'--____ 11 ____ ...J..._ ____ 1_2 ___ ---,7 /Fi\ \..11_J TP 11 86
- 88
~ 107< ~ TP 85' 10 83 < ~ 105 DWG 2008 ZONE E-1 < > 103 '7,104 I R~S I I I I.., VENT--.~*W',/ ,,AVSPV-153 F-153AV (154AV) LUB-153AV OIL (154AV) I <( I DUCT 14' -6"x 9' -6" CONNECTING CONDENSER SHELLS CONDENSER i-, NI lo
- <-1 N °'
<( I 10" SCREEN S-10 0 10"-150MV ~ \ 0 ~VACUUM BREAKER ~ ~ \ I 1 7 I MO -no °' - 3" I/ I 150 C
- < I AR-2 N<Y
~MS <t N 1-AR-104-10 L ___ _ I I ~ 1-AR-103-11/2" ~ LUB-155AV AO (100) (156AV) '--.,.._1+=-t--~--t><J---,p..-,..,,,__,,__,~-,,.--jO IL 155 9 I iAVSPV-155 '----".--f '\.--1 N F-155AV (156AV) (98) AVSPV-165 ~ j LUB-165AV AO 153 I o~ C N I ~ 11/,"-14 ~ ...t- - - AO "'------+---< =..- __ I 154 ~ I F-165AV 11/,"-15 '--f:a:J-' l'---l ~ AIR PURGE CONN. 11/2'-1 s 0 q;9) L.__f'~'----'--'r-'-, PS-4 l1 "0G~132 ~-.,-__,,._VENT r,+-.--+-,-!;:" AVSPV-166 I ~ 1 "PS-4 ~r 9 1-AR-100 14"AR-2 r . L 07 1"0G-133 1-0G-107-1 DWG 2008 ZONE E-11 DWG 2008 ZONE E-1 DWG 2008 ZONE E-2 ! /TE\ I \!:;:,/ I 165 L -- AO ~--------_J L.J '----"'--___ __,, '----' 1-AR-101-14-1 -+--_ n 14"AR-2 \
- 1"-19 14" DWG 2008 ZONE E-12 y,:co c..,,.__c;:.':: 16sAv I
?~ 545 6"-D +;B_Y_M_S_D_D __ -C0~-1 14"..1..r---;=,=o::::;--'f"7:---..J, 14"..L I ~,o~ .-~---, ~----- I '-----L-U_B ___ 1_5_2_A_V ___ ~..,j_ 166AV - - 166 CD 151 AO 14" TO LOOP SEAL PIPE ON----. L._ _______ 54 .. 6h1/4" tioc, AVSPV ---jOIL>-,._+-15-2-+--,-'"-.152AV t SJ-EJTR-1A DWG. 2008 ~ - 152 F-152AV '--'-LO-- ,-TE, BY MSDD. CO. ZONE D-2 JJ. r TF ' ~ Ol 2" 6" 1-C \BEE) 2" 2. c.o 2:cD 2" fTF\ F-166AV OIL LUB-166AV STEAM JET AIR EJECTOR 1A SEE _ _L:=:;a;5t:4~3f-.:,,,.Jl'--~524:'.4~=-<1s5**-'--{=J)--jr-TE\ OIL~ I RMls I ~8'*~ - ~ t-----M-:c~ _ _J ~ -g NOTE g SEE NOTE 9J.l ~
- 3 tj~-i~I.O.8, *~
...... 2" -6" ~ ,,-,_TE I\ - (Th)~ 1st 17 I ~ ~**u, {"ff ~. (!J -,& STEAM JET AIR EJECTOR 1 B CD-~22 SIGHi:---.,_ GLASS f..':.5. STAGE ro SEE o,
- r--
b J_ 5 8 (L.~ __ J '-- NOTE 9 (;J ~ wN C I ~- ~--L.--------~~~~~--j -c, ~ ~i5 INTER CONDENSER NI << -'---l-f-L-~----------L..-, INTER CONDENSER ,--7 co-s21: ~---!:-~--c_D-{~><§j-2-0-----j - AVSPV-151 il tl,.f---- 1 __ '.J VI I "' wm_ ~---~-----------1 0 (11..- ~ - 1 1 1st "' ci: 0 g;~o STAGE CD-529 I I I""' I INTEGRAL----f - ' I DRAIN L __.J COCK CD-523 ~1
- o FOR CONT. SEE DWG. 2008, ZONE D-1 I l 10 SEE NOTE 9
~ 1 "PS 4 <C )l 9~w I (40) 1z QJO f-UlN N I N -
- 10G1091, l
- 13
'._SEE NOTE 9 FOR CONT. SEE DWG. 2008, ZONE D-11 CD,-531 1 I I SIGHT GLASS CD-530 I J.,- INTEGRAL I 1/1 DRAIN I 1 COCK L __ _J !~ 1 "PS-4 I a, 0 I Cl 0 I U1 S-242A, 4" I ~ RUPTUREr--!Dit I -,~Jl,1 "39 BY MSDD. I J co. ~ N - ~ I BJ c~~DDI 4" 1 "40 r : ,,L.'"3--C}-'---..L.-r-"""'---,'I ' ~__,, r S-242B, 4" / RUPTURE DISC 4" -~*f-*- [ 4" r-- 0 I 1 4" ,1, <( 4" 3", f-9 ~(-29-)~[~-8-0--< 1 1 (28) 1 ~E 11,,~6~E 9 AG 2nd STAGE 46 i-~~ 45 ....,_ _ _,-..... -~~----~------, I 47A.,,I ~l:t--i ~ I I L_ill:J 1--.:__SEE _,"c-,~M!'.o, NOTE 7 FROM AFTER CONDENSER st 1 1 ZONE F-5 LUB-157AV ~ AO -..__r--,. OILf----f---:'::";-fr>a.."' 15B ~ "' I OIL (ll 3 't-* 161 ~
2, 47B I
47A L _____ ~ '----1-.j ~ ------------0 0 AVSPV-15~. L_ __ T_ I I 157 -~ I F-157AV p~ - 4"AR-1 1-AR-107-4 I i tA.. I I r-----------..J'---__J I ~ J__ '1' I (30), - 1!1.. I 2nd ~i~E 9 HH
- [-
STAGE Y 54, ~---~---~--~-~-, I IT AFTER CONDENSER lO'"AR-2 ~~ 11/2" VENT 12" 1-AR-108-10 I 478 I "7 I I SEE _/LJ1_E_; NOTE 7 I TO FR-47 I-r-::=l ZONE F-2 ~ (31) N I
- < rfO o
','C 4"AR-1 12"AR-2 r------~----------------- ---7 r------ ________________ ___,: -r-----1 LUB-160AV F-160AV
- 12**11cv 'l 10"160Av".:::'
AO
- 1 foiLl
~ ..__ I AO I
- ~
10"159AV T 159 i I (,) 3"0VERFLOW ~ 12"1 OCV ' 1 ' _f 1A I I 'r T 160 I VENT~ I I I 11/," ~ l _ _ MECHANICAL I G) 3"0VERFLOW ~ ~ AVSPV-160 LJ VACUUM PUMP 1B ~ I ~ SEE NOTE MECHANICAL VACUUM PUMP STUFFING BOX DRAINS (SEE NASH DWG. 14-1865) I I (,) TANK I 11/," I - 1 ..,:2~ ~186 lt=j I RMS OIL LUB-159AV STUFFING I J"', I I T I BOX DRAINS I 11/2.I. - '° I aMS (SEE NASH DWG. ~ ;,.;"' TANK 'i,i Lr 14-1865) 12 1 o VENT 1 2 (,) (,) I fii,__ -"sTNR-MVTA - 0'27 24 1 3/4 20 ' '3/4" 21 ~ "' I 0 G) G) fii I ->- STNR-MVTB ~ 3/4"22 ' 3/4"'23 y,** 11/2'25~ i L _______________ *------------~ 0 _____________ J V3/4" DR-5 '-.--'----_J ---~ '-3/4" DR-5 108" 3/4 "DR-5 "j' .__, ___ ___,,~ 3/4"DR-5 o U) I i5 TO FLOOR DRAIN RMS I I "TO VENT AVSPV-159 U) I i5 TO FLOOR DRAIN I --r:~1-1 " BW-1 S MAKEUP ) 1" 1" FROM DWG. '-------'--1=D~w,'---"-1~1"'1-"--"1=--:--"----------------_L_------'--;,, 2013 ZONE F-8 MAIN STEAM LINE I L - HIGH-HIGH RADIATION - - l_ - _J SHUT-DOWN 1' 3 4 5 6 1 "PS-4 1-0G-109-1 SAMPLE PUMP ASSEMBLY (17-107) ,-- :--~7 0 0 I I I I 1"0G-38 l"PS 4 1 "0.G:;-37 I (FL-1 )7 ;:f fr'---::Jf--'\._'1,r--1,-,0.f;;,_.i--4C-V---~*'7*1---..!..!::.=.:::.'.!:.._..j ,-------------------1---o-G---10_7 __ --------------.'7.,.._ ___ -,..,, oG-ssv5 I I U) ~ 63 (36) 46 I I I I I I 60 f--,P~X+-,--'~f-~-.J I,__ 45 I I I L ____ _j (35) ~*=7 ~ I H OG-70 L
- I !~-----------,
I I I I ICC NUMBER: 5431815 I u ECM NUMBER; DR--2022-oe12 OG-68 OG-69 DRAFTER; DUI
- ~I I
AL I ASSIGNED ENG: RPDUIII I .DAIE; 11/18/22 ~-, ~ OFF GAS R IRMs\ SAMPLING \.._.} CHAMBER 17-104 ~-----------~ OFF-GAS SAMPLE RACK 17-116 I OG-TK-1 OG-(75) /LG\ \...2-.J AR-1 OWC(AR-1) FILTER (17-457l (17-458 1 1/2' AR-115 11/," OWC(AR-1) FROM DWG .------{)e::J--------cc-cl:.,__._,_."------'==.._'_L__ 2091 SH 1 11/2" AR-116 ZONE G-12 '? '? 4"AR-1 -I U)., -,j-0 1-U) I ~ Cl 0 -1 ~- _ _ SAMPLE ~U~ 0 l"OG-36 f-{> ~~--------~ / HYPODERMIC NEEDLE FOR SAMPLE BOTTLE OFF -GAS VIAL SAMPLER) t17-136 VACUUM PUMP (17-106) 1 "QG-34 r, 12" AR-1 1-AR-107-12
- TO OFF-GAS SYSTEMS SEE DWG. 2037 SEE 2" FDR-2 DWG. 20051------i~
SH 2 ZONE D-3 I 16" AR-2 ZONE D-12 & H-11 1-----,1--"'A""R--"'1""0""5 __..,.1-=-s----, 4"AR-1 t -o 1- "' I <( "' <( ro I ~ NI I ro "' 0 <( - I ""1 ! PS-~ 1-AR-107-4 ~F II f;::: I°'"' 1 "PS-4S r/ 1 "OG-92 1 -OG-108-1 f:::: r-___________________ 712',"c,A,CR..,-,,2;-;;--.,-;;,Cl----'-1-"6-,"ArR,__-_,2'--j,*, V. 1 -AR-1 08-16 4" 1-AR-108-12 1-AR-108-12 11 [d'. RMS Al 7 I /PS A-0 I V __ _J ~ AL I [- I C MO 68* 69 163 L-,-~.~J ly'.~ TURBINE 1 BUILDING II
- '.:=---,
I\ A L .T,93 .T.95 33 8" 0 8" NOTE 96 163MV 14"'AR 2 11 ,,.--'---=ff-"..L __ --1: I nJ I: 12CV ' (_ THROTTLEDNOTE l~I ---~ ~~A 1-A 11 ~-. RMS BY W.E. CO. 1-----------7 @-7-0: [- A I ~ I 70
- 71. J MIO l..r(OC 1/2"-26' 7 I M I
a, 0 I <( I NOTES:
- 1. UNLESS DESIGNATED OTHERWISE ALL AIR REMOVAL PIPING ON THIS DWG IS AR-1.
GLAND EXHAUSTERS ~~ ~ '734 8"[K] 164 , ** 1 97 18"164MV
- 2. UNLESS OTHERWISE INDICATED ALL PRESSURE AND/OR FLOW INSTRUMENT ROOT LINES SHALL BE 3/4", ROOT VALVES TO BE 3/4" V253X. LINE UP TO AND INCLUDING ROOT VALVE SHALL BE FURNISHED AND INSTALLED UNDER CONTRACT E69-4.
SB ~---g r----------T---7 I I SEE I PI PT I NOTE 7'J 202 89 1 ~_w __ i-_1_.e __ l'/.. __ LE_J 65 (32) NOTE 11 13CV ~
- In.JI
- : r THROTTLED NOTE MCCF 1-8 11
'--.: ;:r1 'T' 'T' "' -] r-- ' I ~ -] -] -] BY W.E. CO. GLAND STEAM CONDENSER 7 REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY. 8 VERSIONS/REVISIONS BY NPPD NO. DESCRIPTION AC 33 DR-2022-0019 CC [NSTALLATION AD 34 DR-2022-0019 CC REMOVAL AE 35 DR-2022-0512 CC [NSTALLATJON AG 36 DR-2022-0001 ORDER OFT DATE ENG 5431615 OJB 1 10 2 GLHADL.E 5431615 DJB O 12 22 GLHADLE 5431615 DLR 1 16 RPDURR OJB 1 12 2 RPDURR 9 SIGNlflCANT NUhEIER GROUP >-] 2
- 3. FOR DETAILS ON CONDENSER CONNECTIONS SEE CORRESPONDING DESIGNATIONS ON MS & DD CO, DWG. DC-93877 GA 3 SH. 3
- 4. NOT USED.
- 5. ITEMS IDENTIFIED BY (17- ) ARE FURNISHED BY GENERAL ELECTRIC
- 6. ALL VALVE, INSTRUMENT OR EQUIPMENT NUMBERS IN PARENTHESIS (B)ERS ARE NUMBERS TO BE USED IN OPERATING PROCEDURES. THESE NUM ARE ASSIGNED BY NPPD AND WILL NOT BE SHOWN ON PIPING DWGS
- 7. REFERENCE DWG. 1550-Xl 03 FOR INSTRUMENT PIPING AND VALVE INSTALLATION AT INSTRUMENT RACK 1 E.
- 8. ALL VALVES ARE IN THE AIR REMOVAL (AR) SYSTEM UNLESS DESIGNATED OTHERWISE.
- 9. THE START UP POSITION FOR VALVES AR-V-10, 11, 12, 13, CD-V-524, 525,543 AND 544 ASSUMES RED SET IN SERVICE.
- 10. WHERE LINES ARE INTERCONNECTED AND CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROXIMATE ONLY.
- 11. GLAND STEAM EXHAUSTER FLEX HOSES INSTALLED BY CED 6015260.
NOTE: ALL ITEMS MARKED THUS 0 ARE "AS BUILT"' ITEMS AND ARE NOT SHOWN ON PIPING DRAWINGS. DRAWN DATE RRT 1/21/02 5 CHECl<ED DATE AS BUILT 454003592 STATUS: Release STATUS DATE: 01/12/2023 DS APPROVED: RPDURR VER: AG REV: 36 SIZE: F COOPER NUCLEAR STATION FLOW DIAGRAM APPROVED DATE BURNS & ROE a, 0 a, r-- 0 0 AIR REMOVAL SYSTEM ~u f---~---'-----------1 C FIL.MED Sff ~E~grnrn 2009 10 1 1 12 A B C D E F G H J}}