1 2
A B
C D
E F
N -I Cl w
z 0
N Cl U) -
I f-G I
U)
H j
1 2
3 4
5 6
'----'------7-------'-----s---------'------g-----'-----1-o ____
..J..._ ____
1 _1 ___
___Jc.__ ____
1_2 ___ ---,7 8" (783)
(782)
I
<(
w z
0 N
~ -
U)
I f-N I
U)
I *: (780)
'--~.![_ 15CV (X-23 )
DRYWELL 8"RCC-1 2 1/2" 689 N
00 N
~
CONT. ON 2027 ZONE A-5 _,.__,,__,,_-,_,
(X-51b/
DRAIN IA]
DRAIN IA]
TO 702 MV l
I I
I MO IA]
709 0
~ ---t(c 0
~ -
--t( C RCC-1 8" 709MV
' E (X-24 )
u NC 2 RCS,-11 R~C-1 RCS,-.1 I R~C-1
.v "
.v" 1" 200 1"
11/2"
~ 74 74-I j,'4 1" 201 J
RCS,-11 R~C-1 RCS,-*1IR~C-1 1" 20? _ 3/4" 3/4"-
I 1" 203
~'4
3/4 I,,
d,-
1 "
I u u N
REACTOR I
1;J
"' I
-I u u "'
ii)
I Llii:'i
~
1L" 1,, --
30 42~fex\
~
11/2" 23 Irr\
2-2~
PX TO TR2-2-31 28 428
-I u
u
--~
--TO TR2-2-31
-I u u N
-I u u
'oo
' 00 I
N 0 -I u w
RECIRCULATION PUMP 1-A
-J 2 1/2"FLUSH CONN.
21/2" 32
, 7
,,3 693 DRAIN.......
<(,..,.
IA]('.283) 0,0..
N/:
699i 0~
I N
- ~
N 0
f-z N f
00 FAN uO ;(
0, COIL
<CU
<D UNIT ~,
f-z'-< tj FC-R-1A O>
u~ Cl
-'I w f 696 w
o,-
U)
Urn 3" 34 38 8"RCC-1
' '7
,3 692 DRAIN.......
IA] (284) 700i lf.i2 FAN COIL u
UNIT Rj FC-R-1B f 702 3" 35 lex'\
39 8"RCC 1 DRAIN.......
I u u PX 29 432 t----tfrr\-,;T,;;,Er+-- TO
~ TR2-2-31 11/2" RCC-1 11/2" 25
--=-~
- ~
- -To TR2-2-31
-I u u RECIRCULATION PUMP 1-B
~J 2 1/2" FLUSH CONN.
' 7 21/2" 33 e
~-- l7/s1I -- :J5 423 1 REC 101 8" 197 3" 691
~ 7 3" 690 DRAIN--...
IA](285)
IA] (286) 704i 708i lfR FAN fR FAN COIL COIL UNIT
.~
UNIT ~i FC-R-IC FC-R-1D f 707 f 111 3" 36 3" 37 lex'\
40 lex'\
41 lex'\
I IA]
DRAIN 431
~
430
~
435
~
434
~
n
,. (781)
'* (287) 8"RCC 1 A*'~---~
~
00_~_
~~
\456/
~
-I u u N
'2* 43
, e (es\ --0 (es\ --0 (es\ -0 (es\ -0
~
~
~
L
~
L DRYWELL FAN COIL UNITS 11/4" RV10 F
- 2" 42 t
3/4"46
- i 7
CONT. ON
~
2038 ZONE F-7 H~4sf-*
f--,/o;'\i-,p,1,' rl oo 424 ~ ~
SEISMIC CLASS IIS SEISMIC CLASS JS 44 N-6 N-9 DRYWELL EQUIP. DRAIN SUMP HEAT EXCHANGER (20-10) 3 RESTRAINED /
SEISMIC CLASS IIS -
SEE NOTE 6
' ' " \
I
/
/
/
\
I I
I 2"RCC 1 1-REC-102-2" 4
5 N-4 N-7 I
11/2" i3/4" 47 CONT. ON 2038 ZONE F 7 6
7
-I u u "'
ii)
' N I -
0 -I u w
"' I -
-I u
u
~
7 I
I I
\
/
I
\
8
/
/
NOTES:
- 1.
UNLESS OTHERWISE INDICATED ALL PRESSURE AND/OR FLOW INSTRUMENT ROOT VALVES SHALL BE 3/4": ROOT VALVES FOR CARBON STEEL SYSTEMS SHALL BE 3/4'V253X.
ROOT VALVES FOR STAINLESS STEEL SYSTEMS SHALL BE 3/4'V226X.
LINE UP TD AND INCLUDING ROOT VALVES SHALL BE FURNISHED AND INSTALLED UNDER CONTRACT E-69-4.
- 2.
ALL TEMPERATURE TEST AND PROTECTING WELL PENETRATIONS SHALL BE 1 "NPT UNLESS OTHERWISE NOTED.
- 3.
AT SAMPLE POINTS, CONNECTIONS, PROBES AND ROOT VALVES SHALL BE FURNISTHED AND INSTALLED UNDER CONTRACT E-69-4.
PROBES SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH CONTRACT PARA. 3.4.2 AND DWG. SP-07211, FIG. NUMBER AS NOTED.
CONTINUATION OF SAMPLE PIPING BY E-70-3.
- 4.
HIGH POINT VENTS AND LOW POINT DRAINS NOT SHOWN AND SHALL BE SUPPLIED BY CONTRACT E-69-4.
- 5.
- INDICATES SUPPLIED BY EQUIPMENT VENDOR.
- 6.
RCC-1 SYSTEM PIPING 8" SIZE AND LARGER INSIDE OF THE DRYWELL ARE SUPPORTED FOR CLASS IS RESTRAINED CRITERIA.
- 7.
ALL VALVE NUMBERS IN PARENTHESIS ( )
ARE NUMBERS TO BE USED IN OPERATING PROCEDURES.
THESE NUMBERS ARE ASSIGNED BY NPPD AND WILL NOT BE SHOWN ON PIPING DRAWINGS.
- 8.
ALL VALVES ARE IN THE REC SYSTEM UNLESS OTHERWISE DESIGNATED.
- 9.
INSTRUMENT, SAMPLE, TEST, DRAIN AND VENT LINES ARE NOT ALWAYS THE SAME CLASS AS THE MAIN LINE AND THESE BOUNDARIES ARE TOO NUMEROUS TD IDENTIFY IN THIS MANNER. (SEE ISi PROGRAM BOUNDARY DESCRIPTIONS FOR DETAILS)
- 10. CB IS PRIMARY CONTAINMENT BOUNDRY.
- 11. WHERE LINES ARE INTERCONNECTED AND CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROXIMATE ONLY.
NOTE: ALL ITEMS MARKED THUS IA] ARE "AS-BUILT" ITEMS AND ARE NOT SHOWN ON PIPING DRAWINGS.
SIGNIFICANT NUIIIBER REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY.
FOR PREVIOUS REVISIONS SEE SUPERSEDED CARDS.
GROUP 4
VERSIONS/REVISIONS BY N.P.P.D.
NO.
DESCRIPTION DFT DATE ENG AD 23 DR-2013-0598 FROM VERSION AB DJB 10 18 1 KKKUKE t:,E. 24 DR-2013-0598 FROM VERSION AC PAM 10 21 1 KKKUKE 9
COOPER NUCLEAR STATION FLOW DIAGRAM REACTOR BUILDING CLOSED COOLING WATER SYSTEM 10 1 1 DRAWN DATE CHEa<ED DATE APPROVED DATE SEE ~~EDED AS BUILT 454003622 STATUS: Release STATUS DATE: 10/21/2016 DS APPROVED: KKKUKER VER: AE REV: 24 SIZE: F I')
0, BURNS & ROE r---
0 0
~u t----r---~---------i C FILMED 2031 SH 1
~
12 A
B C
D E
F G
H j