Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 pg. i VALLECITOS NUCLEAR CENTER REACTOR FACILITIES RADIOLOGICAL EMERGENCY PLAN Revision 1ed & Approved REDACTED - PUBLIC VERSION June 9, 2021
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 pg. ii TABLE OF CONTENTS 1 INTRODUCTION.................................................................................................................... 1 1.1 Objective.......................................................................................................................... 1 1.2 Scope and Regulatory Basis............................................................................................. 1 1.3 Location........................................................................................................................... 3 1.4 Reactor Description......................................................................................................... 4 2 DEFINITIONS.......................................................................................................................... 6 3 ORGANIZATION AND RESPONSIBILITIES...................................................................... 8 3.1 VNC Emergency Response Organization (ERO)............................................................ 8 3.2 Off-Site Agencies........................................................................................................... 11 3.3 Off-Site Support Organizations..................................................................................... 12 4 EMERGENCY CLASSIFICATION SYSTEM..................................................................... 14 4.1 Unusual Event................................................................................................................ 14 4.2 Alert............................................................................................................................... 15 4.3 Site Area Emergency..................................................................................................... 15 4.4 General Emergency........................................................................................................ 16 5 EMERGENCY ACTION LEVELS........................................................................................ 17 5.1 Unusual Event................................................................................................................ 17 5.2 Alert............................................................................................................................... 21 6 EMERGENCY PLANNING ZONEs (EPZs)......................................................................... 23 6.1 NTR EPZ....................................................................................................................... 23 6.2 GETR, VBWR, and EVESR EPZs................................................................................ 23 7 EMERGENCY RESPONSE................................................................................................... 24 7.1 Activation of Emergency Organizations........................................................................ 24 7.2 Assessment Actions....................................................................................................... 25 7.3 Corrective Actions......................................................................................................... 25 7.4 Protective Actions.......................................................................................................... 25
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 pg. iii 8 EMERGENCY FACILITIES AND EQUIPMENT................................................................ 28 8.1 Emergency Control Center (ECC)................................................................................. 28 8.2 Assessment Facilities..................................................................................................... 28 8.3 First Aid and Medical Facilities..................................................................................... 28 8.4 Communications Equipment.......................................................................................... 29 8.5 Contingency Planning.................................................................................................... 29 9 RECOVERY........................................................................................................................... 31 9.1 Reentry........................................................................................................................... 31 9.2 Recovery........................................................................................................................ 31 10 MAINTAINING EMERGENCY PREPAREDNESS............................................................ 33 10.1 Training and Drills......................................................................................................... 33 10.2 Plan Review and Update................................................................................................ 35 10.3 Maintenance and Inventory of Emergency Equipment, Instrumentation, and Supplies 36 Appendix 1, References.................................................................................................................37 Appendix 2, Emergency Plan Implementing Procedures..............................................................38 Appendix 3, EAL Technical Bases for Effluent Releases.............................................................39
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 pg. iv DOCUMENT REVIEW This document is required to be reviewed Biennially.
Reviews finding technical or procedural errors will require immediate correction by revision.
The first (original) review of any revision will be located on the front cover of this plan. Reviews finding administrative/format errors may be noted in the comments and corrected as time permits.
Electronic Signatures are authorized for review and approval.
Date Reviewer Comments (if necessary) 2/12/21 NRC Approval 6/9/21 Revised & Implemented
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 1 of 39 1
INTRODUCTION Planning Standard (ANSI/ANS-15.16 Section 3.1 & NUREG-0849 Section 1.0)
The plan shall briefly introduce the type of reactor, the reactors purpose, where it is located, and the purposes of the emergency plan.
The purpose of the introduction is to provide a general orientation and common understanding about the reactor and the objectives of the plan for those members of the reactor organization, the public, and local, county, state, and federal agencies that will read and study the plan.
1.1 Objective This emergency plan contains security related information and describes the approach used to identify, communicate, respond to and minimize the consequences of classified emergencies; it documents regulatory compliance and site specific commitments; and provides a basis for the response and maintenance implementing procedure instructions.
This plan will be provided to external stakeholders as appropriate.
1.2 Scope and Regulatory Basis 1.2.1 Scope There are four reactor facilities at the Vallecitos Nuclear Center (VNC) that are licensed by the NRC under 10 CFR 50 requirements; the Nuclear Test Reactor (NTR), which has a current operating license, and the other three reactor facilities which are in a shutdown SAFSTOR decommissioning mode with possess only licenses:
Vallecitos Boiling Water Reactor (VBWR) DPR-1 ESADA Vallecitos Experimental Superheat Reactor (EVESR) DR-10 GE Test Reactor (GETR) TR-1 This emergency plan has been developed for the NTR, license R-33, in accordance with the applicable regulations, guidance and information documents. Per NRC letter dated 03/19/13 and DRK-2013-14 response the NTR emergency plan and implementing procedures are sufficient to meet the emergency planning requirements for the three shutdown defueled reactors (spent fuel for the SAFSTOR facilities is no longer maintained or stored on site).
Other VNC facilities which are governed under Special Nuclear Material (SNM) federal and state licenses do not contain sufficient radioactive materials to require an emergency plan (NRC Letter SNM-960 Amendment 5 12/20/90 and GEH 03/08/18 Memo, Evaluation that a VNC Radiological Emergency Plan is not Required for Radioactive Material Authorized by the State of California).
Building 102 contains administrative offices and refurbishment shop areas,
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 2 of 39 Building 103 consists of administrative offices and laboratories equipped and designed to handle small amounts of radioactive materials in the performance of research, development, and analytical chemistry and metallurgical services.
Building 105 contains laboratory areas with equipment for research and special measurement that involves minimal amounts of radioactive material used in conjunction with spectrometric equipment.
Building 106 houses support facilities (e.g., electrical shop, instrument shop, radiological instrument calibration facilities, etc.), an x-ray room, and offices.
Building 349 contains the site low-level liquid waste evaporator.
400 and 401 Areas consists of offices and spaces that may contain laboratory quantities of radioactive material.
Hillside Storage Area is used to store Low Level Radwaste. Irradiated fuel segments and hardware are stored in the above ground bunker area.
The VNC Emergency Response Organization (ERO) may be used to address events occurring at those facilities outside of a declared emergency. Event response involving SNM facilities are primarily controlled through site industrial / hazards procedures that are outside the scope of this emergency plan.
1.2.2 NTR Regulatory Basis NRC Regulatory Guide 2.6, Emergency Planning for Research and Test Reactors, provides test and research reactor licensees with a method that the NRC considers acceptable for use in complying with the following regulations on the content of their emergency plans:
10 CFR 50.34(b)(6)(v) requires that each application for a Part 50 license to operate a facility include a final safety analysis report that contains, along with other information, the applicants plans for coping with emergencies, including the items specified in Appendix E to 10 CFR 50.
Note - NTR is the only facility at VNC that is required to maintain a safety analysis report.
10 CFR 50.54(q) requires Part 50 licensees to follow and maintain the effectiveness of emergency plans that meet the requirements of 10 CFR 50 Appendix E.
10 CFR 50 Appendix E identifies the minimum requirements for emergency plans. It also indicates that because operation of test reactors involve distinct considerations, the size of the emergency preparedness zone (EPZ) and degree of compliance with requirements in Appendix E, sections I through V, as necessary, will be determined on a case-by-case basis using this regulatory guide for research and test reactor, and other non-power production and utilization facility emergency response plans.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 3 of 39 Regulatory Guide 2.6 Revision 2 endorses the consensus standard ANSI/ANS-15.16-2015, stating that it provides specific acceptance criteria that; (1) comply with the applicable requirements contained in the above listed regulations, and (2) supply a basis to develop acceptable emergency response plans and improve emergency preparedness.
Consistent with ANSI/ANS-15.16, NUREG-0849 provides areas of review, planning standards, and items for NRC staff to evaluate a licensees compliance with the applicable emergency planning requirements. NUREG-0849 is used as a basis for the level of planning detail included in this document.
1.3 Location VNC, owned and operated by General Electric Hitachi (GEH), is located in the west-central portion of the State of California about 15 miles east of the southern end of San Francisco Bay, approximately 35 air miles east-southeast of San Francisco and 20 air miles north of San Jose. It lies on the north side of the Vallecitos Valley. The nearest sizeable towns are Pleasanton, located 4.1 miles to the north-northwest and Livermore, located 6.2 miles to the northeast.
The site is on the north side of Vallecitos Road (State Route 84), which is a two and four-lane paved highway. The majority of the site is undeveloped with hills ranging in elevation from 600 to 900 feet above mean sea level. Access to Vallecitos Road from the south-west is via Interstate Highway 680, and from the north-east via Stanley Boulevard or Interstate Highway 580.
Figure 1 VNC Bay Area Map
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 4 of 39 1.4 Reactor Description The NTR,
, is a heterogeneous enriched-uranium graphite-moderated and -reflected light-water-cooled thermal reactor. The reactor is a variable level neutron source used in the research, development, analytical and commercial programs of GEH and its customers. The NTR is primarily engaged in neutron radiography non-destructive material imaging. Per the General Electric Nuclear Test Reactor Safety Analysis Report Section 1.1, the NTR is licensed to operate at power levels not in excess of 100 kW (thermal).
GETR and related structures are located in the 200 Area. VBWR and EVESR and related structures are located in the 300 Area. These facilities are not occupied. Only relatively minor activities associated with inspection and maintenance of the deactivated facilities are currently performed. No fuel assemblies from these reactors remain on-site. Radiation and contamination levels in all of the SAFSTOR facilities are significantly reduced since shut-down several decades ago and well below values typical of operating research & test reactors.
Those and other areas regulated under separate licenses at VNC that contain radioactive material are illustrated Figure 1-2.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related Information - Withhold from Public Disclosure per 10CFR2.390 Page 5 of 39 Figure 1 VNC Site Layout
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 6 of 39 2
DEFINITIONS Planning Standard (& ANSI/ANS-15.16 Section 3.2 & NUREG-0849 Section 2.0)
Terms unique to the reactor facility or that have a special meaning when used in the plan shall be defined in the plan.
Assessment Actions - Those actions taken during or after an emergency to obtain and process information necessary to make decisions to implement corrective, protective and recovery actions.
Corrective Actions - Those actions taken to arrest and terminate an emergency.
Direct - Directing involves obtaining data and recommendations, processing this input, and then ensuring the performance of one or more actions or activities such as additional assessment, protective or corrective actions. The performance of actions or activities is generally through responsible intermediaries.
Emergency Action Level (EAL) - A pre-determined, site-specific, observable threshold for an initiating condition that, when met or exceeded, result in actions such as (a) establishing emergency classes and (b) initiating appropriate emergency measures.
Emergency Classification Level (ECL) - One of a set of names or titles established by the US Nuclear Regulatory Commission (NRC) for grouping off-normal events or conditions according to (1) potential or actual effects or consequences, and (2) resulting onsite and offsite response actions. The emergency classification levels, in ascending order of severity, are:
Unusual Event (UE)
Alert Site Area Emergency (SAE)
General Emergency (GE)
Emergency Control Center (ECC) - The primary base of VNC emergency operations during a declared event to facilitate the management and coordination of overall emergency response.
Emergency Planning Zone (EPZ) - Area for which off-site emergency planning is performed to assure that prompt and effective actions can be taken to protect the public in the event of an accident. The EPZ size is dependent on reactor power level and the distance beyond the site boundary at which the protective action guides could be exceeded.
Refer to Section 6 for the VNC facility specific EPZs.
Fire - Combustion characterized by heat and light. Sources of smoke such as slipping drive belts or overheated electrical equipment do not constitute fires. Observation of flame is preferred but is NOT required if large quantities of smoke and heat are observed.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 7 of 39 Holding Statement - A statement reviewed and approved for accuracy prior to issuance, that provides prepared information to distribute in response to rumors or inquiries from news or social media outlets, community officials, regulatory agencies, or other interested parties.
Off-Normal Condition - A situation or event, other than those addressed by site personnel on a routine basis, which are evaluated for emergency plan entry by the Emergency Director.
Off-Site - The geographical area that is beyond the site boundary.
On-Site - The geographical area that is within the site boundary.
Operations Boundary - The area within the site boundary such as the reactor building (or the nearest physical personnel barrier in cases where the reactor building is not a principal physical personnel barrier) where GEH has direct authority over all activities. The area within this boundary shall have prearranged evacuation procedures known to personnel frequenting the area.
Refer to Section 6 for the site specific reactor facility operational boundaries.
Protective Actions - Those actions taken to mitigate the consequences of an emergency.
Recovery Actions - Those actions taken after an emergency to restore the area to the pre-emergency condition.
Site Boundary - The site boundary is a boundary that does not necessarily have restrictive barriers and surrounds the operations boundary wherein GEH may directly initiate emergency activities. The area within the site boundary may be frequented by people unacquainted with the reactor operations.
For purposes of this plan, the site boundary is the GEH property fence designated as the Vallecitos Nuclear Center.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 8 of 39 3
ORGANIZATION AND RESPONSIBILITIES Planning Standard (ANSI/ANS-15.16 Section 3.3 & NUREG-0849 Section 3.0)
Responsibility for planning and implementing all emergency measures within the site boundary rests with the owner/operator of the reactor facility. The plan shall describe the emergency organization that would be activated to cope with radiological emergencies that includes the on-site emergency organization and any augmentation from off-site groups. Persons or groups that will fill positions in the emergency organization should be identified by their normal everyday title.
3.1 VNC Emergency Response Organization (ERO)
VNC emergency preparedness response adapts the normal site organization into an ERO that is activated upon declaration of an emergency classification level. The VNC ERO is shown below.
Figure 3 VNC Emergency Response Organization and Support Interface Emergency Director Facilities Manager Maintenance and Craft Personnel RC & EHS Manager Nuclear / Licensing /
Rad Safety / Security
/ EHS Personnel Bldg Emergency Coordinator Bldg Emergency Team / Assembly Area Leader Fire Chief & Fire Team Offsite Incident Command Offsite Response Support GEH Headquarters Emergency Response Support Nuclear / Licensing / Rad Safety / EHS Support Communications / Media Support
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 9 of 39 Following evaluation of the event, the Emergency Director will determine whether an emergency declaration is warranted, staff the appropriate ERO positions and notify Federal and State agencies.
Responsibilities and authority of members of the ERO, management, and support specialists include those listed below. Additional responsibilities and duties may be assigned in implementing procedures.
3.1.1 Emergency Director As part of overall command and control of the event, the Emergency Director coordinates the collection and evaluation of information from the event location, prioritizes response and mitigating activities of dispatched personnel, and manages the Emergency Control Center (ECC) and ERO in order to provide continuous assessment of the situation regarding the magnitude of the emergency, projected consequences, and effectiveness of the response measures taken.
Specifically, the Emergency Director has the overall responsibility and authority for VNC emergency response activities, including:
Classifying and declaring emergencies Ensuring notification of the VNC ERO and augmenting as necessary Ensuring notification of the appropriate offsite agencies Mobilizing corporate and other support resources as necessary Coordinating response activities (including off-site assistance if requested) to mitigate the consequences of the event Directing on-site protective actions to prevent or minimize personnel hazard and injury Authorizing reentry into facilities or areas that may have been evacuated during the emergency Authorizing volunteer emergency workers to incur radiation exposures in excess of normal occupational limits Escalating the emergency classification level or terminating the event These responsibilities can only be delegated to other personnel qualified as an Emergency Director.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 10 of 39 The Emergency Director is also responsible for providing holding statement information about the emergency to the corporate communications and public relations function for release to the news media and the public.
3.1.2 3.1.3 Radiation Monitoring Technician (RMT)
RMTs are trained for implementing and coordinating radiological emergency response activities. If not fulfilling the role of Emergency Director, the RMT may act as an assistant Emergency Director to provide advice on radiological survey and assessment, personnel and facility decontamination, exposure controls, etc. This includes dose assessments and recommendation of on-site protective actions as appropriate.
3.1.4 Facilities Manager The Facilities Manager supervises emergency repair/damage control teams associated with accident mitigation. The Facilities Manager assesses the personnel resources and technical skill levels required to mitigate the emergency situation and requests augmentation of the ERO staff as appropriate.
3.1.4.1 Maintenance and Craft Technicians Maintenance and craft technicians, besides those who are of a specific BET, may be called to respond to emergencies during normal working hours and may be called in during off-hours to assist in emergencies.
3.1.5 Manager, Regulatory Compliance & Environmental Health and Safety (RC & EHS)
The Manager, RC & EHS, is responsible for supporting assessment of the emergency and directing assessment, corrective, and protective activities concerning criticality safety and radiation protection.
3.1.6 Building Emergency Coordinator (BEC) / Building Emergency Team (BET)
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 11 of 39 3.1.6.1 Assembly Area Leader 3.1.7 Site Fire Chief 3.2 Off-Site Agencies Federal, state and local agency response assistance is not anticipated since no radiological event at VNC is capable of reaching a level requiring protection of the public (local source term resulting in a release of radioactivity is not sufficient to result in exposure which exceed EPA PAG levels beyond the site boundary).
Offsite agencies are notified of declared emergencies as described in Section 7.
3.2.1 Federal Agencies Control, responsibility and interface of federal organizations is governed by the National Response Framework (NRF) and the Nuclear/Radiological Incident Annex to the NRF when they are notified of an event at a nuclear research or test reactor facility.
The NRC acts as the lead federal agency with regard to technical matters during a nuclear incident including radiological assistance. The NRC maintains an Incident Response Plan (IRP). The IRP objectives are to provide for protection of the public health and safety, property, and the environment, from the effects of radiological incidents that may occur at licensed facilities. The objectives of the agency plan set forth the organizational and management concepts and responsibilities needed to assure that NRC has an effective emergency response program.
Department of Homeland Security (DHS) may provide leadership capabilities in the event there are incidents related to security.
3.2.2 State Agencies The California Office of Emergency Services (OES) is the state authority for coordination of all state response. Cal OES is also the primary state response agency that coordinates the state's response to requests for assistance from local jurisdictions.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 12 of 39 If an event is of significant magnitude to require establishment of a near site Incident Command Post (ICP), it will be established through Cal OES and the Emergency Director will communicate with and potentially provide a liaison to the ICP to assist in coordinating response efforts.
3.3 Off-Site Support Organizations Certain supporting services that may be needed during or after a radiological emergency are available from local off-site organizations. These services are described below. Refer to Section 10.2.2, Review and Update, for a current list of MOUs with off-site support organizations.
3.3.1 First Aid Assistance First aid assistance is available through the Alameda County Emergency Services Dispatch (911). Typically, local fire Emergency Medical Service (EMS) units are sent to respond for first aid related issues. However, other trained personal, such as from local law enforcement, may be dispatched for first aid service as determined by the county dispatch process.
A written agreement is maintained with local emergency medical services for assistance that would be requested to come on-site.
3.3.2 Medical Treatment Facilities Access to local area medical facilities and professional care for radiation-exposed or contaminated individuals requiring medical treatment is provided through written agreement with a private professional organization.
3.3.3 Ambulance Service Ambulance service is available through the Alameda County Emergency Services Dispatch (911). If the nature of the emergency or injury warrants, 911 is called and injured personnel are transported via ambulance to one of several local area medical facilities.
A written agreement is maintained with a local private ambulance service company regarding transport of injured or ill personnel to an offsite medical treatment facility, who may be contaminated.
3.3.4 Firefighting Assistance When needed, a request for firefighting assistance will be made through the Alameda County Emergency Services Dispatch (911).
The first arriving responders at VNC may come from the closest fire station in Sunol. If additional assistance is needed, the fire incident commander will make the request for additional resources through ACFD.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 13 of 39 A written agreement is maintained with local fire services for assistance that would be requested to come on-site.
3.3.5 Police Assistance Police assistance is available for law enforcement activities and off-site traffic and/or crowd control from county and state law enforcement agencies with jurisdiction over the areas and roadway surrounding VNC.
A written agreement is maintained with local law enforcement for assistance that would be requested to come on-site.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 14 of 39 4
EMERGENCY CLASSIFICATION SYSTEM Planning Standard (ANSI/ANS-15.16 Section 3.4 & NUREG-0849 Section 4.0)
The emergency plan shall describe several classes of emergency situations covering the spectrum of emergency conditions that involve the alerting or activating of progressively larger segments of the emergency organization. To provide for improved communications between the licensee or owner/operator and federal, state, and local agencies and organizations, the most severe accidents are standardized in four classes of emergency conditions that group the accidents according to the severity of off-site radiological consequences. Each emergency plan shall include only those standard classes appropriate for dealing with accident consequences determined to be credible for the specific facility.
Each class of emergency should be associated with particular emergency action levels and with particular immediate actions to provide appropriate graded response.
This plan is based on the classification system described in ANSI/ANS-15.16-2015. Events are standardized in four classes of emergency conditions which group them according to the severity of off-site radiological consequences. These classes in order of increasing severity are:
Unusual Event Alert Site Area Emergency General Emergency 4.1 Unusual Event Unusual Events may be initiated by either man-made events or natural phenomena that can be recognized as creating a significant hazard potential that was previously nonexistent. There is usually time available to take precautionary and corrective steps to prevent the escalation of the accident or to mitigate the consequences should it occur. No releases of radioactive material requiring off-site responses are expected.
Although the situation may not have caused damage to the reactor, it may warrant an immediate shutdown of the reactor or interruption of nonessential routine functions.
The ED ERO position will be activated, with other ERO positions potentially notified to increase the state of readiness as warranted by the circumstances.
Actions taken in response to this emergency class are:
- 1. Notify State and NRC of Unusual Event emergency declaration per Section 7.1.2
- 2. Augment ERO resources if needed
- 3. Assess and respond
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 15 of 39
- 4. Escalate to a more severe class, if appropriate or Terminate the emergency with verbal summary to offsite authorities 4.2 Alert Events leading to an Alert would be of such radiological significance as to require notification of the GE and off-site emergency organizations and their response as appropriate for the specific emergency situation. Under this class, it is unlikely that off-site response or monitoring would be necessary. Reactor shutdown is a highly probable response action. Protective evacuations or isolation of certain areas within the operations boundary or within the site boundary may be necessary.
Actions taken in response to this emergency class are:
- 1. Notify State and NRC of Alert emergency declaration per Section 7.1.2
- 3. Dispatch on-site monitoring teams
- 4. Assess and respond
- 5. Make staff available for consultation with NRC and State on a periodic basis
- 6. Terminate the emergency with verbal summary to offsite authorities 4.3 Site Area Emergency A site area emergency may be initiated when events such as major damage of fuel or cladding and actual or imminent failure of other physical barriers containing fission products in reactor fuel or fueled experiments have occurred, and projected off-site radiological consequences exceed action levels in section 5.0. Monitoring at the site boundary should be conducted to assess the need for off-site protective actions.
Protective measures on-site may be necessary.
The results of NTR Safety Analysis Report (SAR) Section 13 accident analyses show that there are no credible events that could cause fuel melt or a significant release of fission products from the fuel. Even if catastrophic non-mechanistic failure of the NTR facilities is assumed, there are no potential consequences more severe than those associated with the accidents analyzed in SAR Chapter 13.
SAR Section 13.5.3.1 provides radiological consequence analysis of accidental explosions. Assuming a 1% release and stable atmospheric conditions (inversion),
maximum site boundary doses are less than 20 mRem to the thyroid and 1 mRem to the whole body under this combination of circumstances.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 16 of 39 SAR Table 13-3 provides dose summaries for site boundary exposure to the NTR Design Basis Accident (DBA), which is an experiment accident event. Total Body 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> submersion dose is 4.54E-3 Rem (4.5 mRem) and CDE Thyroid is 1.61E-1 Rem (161 mRem).
The limiting EAL exposure threshold is for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Even assuming the most conservative case where the site boundary exposure would be a product of an initial peak at the onset of the release with a rapid decline thereafter (yielding the 2 DBA hour dose within the 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> threshold), the NTR is not capable of reaching the Site Area Emergency radiological thresholds.
4.4 General Emergency A general emergency may be initiated by accidents that result in an uncontrolled release of radioactive material into the air, water, or ground to the extent that protective actions off-site may be necessary. This class of accident is not credible for most research reactors. Therefore, most research reactors would not include this class as part of their emergency plans.
Refer to the technical basis in Section 4.3, Site Area Emergency, documenting that the NTR radiological source term is insufficient to meet the level of Site Area Emergency or General Emergency classification levels.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 17 of 39 5
EMERGENCY ACTION LEVELS Planning Standard (ANSI/ANS-15.16 Section 3.5 & NUREG-0849 Section 5.0)
Because of the wide diversity of research reactors (power level, engineered safety features, site environment, etc.), those conditions that might initiate or signal a radiological incident having particular off-site consequences will vary widely among facilities. Action levels should be established in terms of effluent monitors or other plant parameters from which the dose rates and radiological effluent releases at the site boundary can be projected.
To establish effluent action levels, facilities that have meteorological information available may base the action levels on actual meteorological conditions; otherwise, the criteria to be used for downwind concentration should be taken from ANSI/ANS-15.7-1977; R1986 (withdrawn),
Research Reactor Site Evaluation, Sec. 4, Criteria for Downwind Concentration [3]. Each emergency plan shall establish EALs appropriate for the specific facility and consistent with Table 1.
The emergency plan shall include EALs to initiate protective actions for members of the general public and facility staff on-site.
5.1 Unusual Event ANSI/ANS-15.16 Table 1 Initiating Condition VNC Emergency Action Level(s)
Abnormal Radiological Conditions Actual or projected radiological effluent at the site boundary that is calculated (or measured) to result in either of the following conditions, both of which are based on an exposure of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or less:
(1) A deep dose equivalent of 0.15 mSv (15 mrem)
OR (2) A committed effective dose equivalent of 0.15mSv (15 mrem) based on the following considerations:
100 EC X 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> = 2.4 X103 EC-hour
~0.15 mSv (15 mrem) (for radionuclides other than noble gases) 50 EC X 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> = 1.2 X103 EC-hour
~0.15 mSv [15 mrem] (for noble gases)
RU1 Actual or projected dose at the site boundary:
> 15 mrem DDE over a 24-hour period
> 15 mrem CEDE over a 24-hour period RU2 Actual or projected dose rates at the site boundary:
> 4 mrem/hr DDE
> 20 mrem CDE thyroid for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of inhalation RU3 Radiological effluent level (Ci/cc) meet any of the following for greater than 60 minutes:
> 2.4E-5 NTR Noble Gas Stack Monitor
> 2.4E-5 NTR Particulate Stack Monitor
> 2.4E-1 from any reactor facility effluent Noble Gas sample
> 4.7E-3 from any reactor facility effluent Halogen sample
> 2.4E-7 from any reactor facility effluent Particulate sample
> 2.4E-5 from any reactor facility effluent Particulate sample
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 18 of 39 ANSI/ANS-15.16 Table 1 Initiating Condition VNC Emergency Action Level(s)
Security Conditions Credible security threat affecting the reactor facility SU1 Credible security threat affecting a reactor facility Receipt of bomb threat affecting the reactor facility SU2 Credible bomb threat affecting a reactor facility Hazardous Conditions Report or observation of a severe natural phenomenon affecting the reactor site HU1 Report or observation of any of the following severe natural phenomenon affecting the NTR:
Tornado strike within the site boundary
> 75 mph winds for > 1 minute NTR Seismic Alarm and felt by onsite personnel Fire within the reactor facility not extinguished within 15 minutes HU2 Fire within a reactor facility not extinguished within 15 minutes of detection 5.1.1 RU1 Technical Basis The RU1 threshold values are directly related to the ANSI/ANS-15.16-2015 initiating condition values.
For the purpose of event declaration, direct measurement by survey instrument adjusted for exposure period is considered equivalent to an isotopic sample and analysis (where the determination of actual DDE and CEDE would not be timely).
5.1.2 RU2 Technical Basis Per ANSI/ANS-15.16, if the exposure time is < 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, the EC multiplier can be increased proportionately, provided that the values of 2.4x103 and 1.2x103 EC-hour are used to declare an Unusual Event; the proportional increases are 5 for an alert and 25 for a site area emergency.
Using this relationship, the RU2 threshold values are one fifth the RA2 threshold values.
Direct measurement by survey instrument is considered equivalent for purposed of event declaration as isotopic sample and analysis to determine actual DDE would not be timely.
CDE thyroid is determined by portable air sample and gross count adjustment for I-131 source term assumptions.
5.1.3 RU3 Technical Basis Per ANSI/ANS-15.16, it is expected that licensees will determine the relationship of the EAL dose levels at the site boundary to instrumentation readings and/or safety analysis accident conditions for their specific facilities.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 19 of 39 NTR Vent Stack Noble Gas Monitor instrument range is 1E-06 to 1E+01 NTR Vent Stack Particulate Monitor instrument range is 2E-11 to 2E-04 Refer to Appendix 3 for the calculations supporting the threshold values for RU3.
5.1.4 SU1 Technical Basis Per ANSI/ANS-15.16, the situation that may lead to an emergency class described in the subsections of NUREG-0849, Section. 4.0 may be referenced as EALs appropriate to the emergency class.
Per NUREG-0849, situations that may lead to this class include: (1) threats to or breaches of security such as bomb threats or civil disturbances directed toward the reactor.
The SU1 security threat threshold is based on the ANSI/ANS-15.16-2015 initiating condition wording.
A civil disturbance alone would not meet the definition of an unusual event as conditions for this description could be as low as a single protester staging at the entrance to the site access road. However, a civil disturbance level consistent with the Unusual Event definition would be a credible security threat and declared per SU1.
5.1.5 SU2 Technical Basis Per ANSI/ANS-15.16, the situation that may lead to an emergency class described in the subsections of NUREG-0849, Section. 4.0 may be referenced as EALs appropriate to the emergency class.
Per NUREG-0849, situations that may lead to this class include: (1) threats to or breaches of security such as bomb threats or civil disturbances directed toward the reactor.
The SU2 bomb threat threshold is based on the ANSI/ANS-15.16-2015 initiating condition wording clarified that the it be a credible threat for consistency with the SU1 security threat wording.
5.1.6 HU1 Technical Basis Per ANSI/ANS-15.16, the situation that may lead to an emergency class described in the subsections of NUREG-0849, Section 4.0 may be referenced as EALs appropriate to the emergency class.
Per NUREG-0849, situations that may lead to this class include: (2) natural phenomena, such as tornados in the immediate vicinity of the reactor, hurricanes, or earthquakes felt in the facility.
Tornado in the immediate vicinity of the reactor is defined as a tornado strike within the site boundary. Tornado EF rating is not a consideration as EF-0 winds are projected as 65 - 85 mph, which meets the intent of the initiating condition. Strike means that the tornado touched down.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 20 of 39 Hurricanes have not historically been experienced at VNC. A threshold of sustained winds > 75 mph measured on site will be used to meet the intent of the initiating condition. Sustained means a period of at least 1 minute.
The combination of NTR Seismic Alarm and felt by personnel considered equivalent to an earthquake of Magnitude 4 at the site. Richter Scale Magnitude 4 earthquakes correlate to a level IV Modified Mercalli Scale identified as being felt indoors by many, by few outside, where dishes and windows rattle.
5.1.7 HU2 Technical Basis Per ANSI/ANS-15.16, the situation that may lead to an emergency class described in the subsections of NUREG-0849, Section 4.0 may be referenced as EALs appropriate to the emergency class.
Per NUREG-0849, situations that may lead to this class include: (3) facility emergencies, such as prolonged fires, fuel damage indicated by high coolant fission product activity, or high offgas activity.
The HU2 fire threshold is related to the ANSI/ANS-15.16-2015 initiating condition wording with the additional specification that the 15 minute time period begins when the fire is detected (by fire alarm or direct observation).
Coolant activity at VNC is monitored on a monthly basis and is not suitable as an EAL threshold.
Thresholds for abnormal radiological conditions, which include high gaseous activity are provided in the RUx series EALs.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 21 of 39 5.2 Alert ANSI/ANS-15.16 Table 1 VNC Emergency Action Levels Abnormal Radiological Conditions Actual or projected radiological effluent at the site boundary that is calculated (or measured) to result in either of the following conditions, both of which are based on an exposure of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or less:
(1) A deep dose equivalent of 0.75 mSv (75 mrem)
OR (2) A committed effective dose equivalent of 0.75mSv (75 mrem) based on the following considerations:
500 EC X 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> = 1.2 X104 EC-hour
~0.75 mSv (75 mrem) (for radionuclides other than noble gases) 250 EC X 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> = 6.0 X103 EC-hour
~0.75 mSv [75 mrem] (for noble gases)
RA1 Actual or projected dose at the site boundary:
> 75 mrem TEDE over a 24-hour period
> 75 mrem CEDE over a 24-hour period RA2 Actual or projected dose rates at the site boundary:
> 20 mrem/hr TEDE
> 100 mrem CDE thyroid for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of inhalation RA3 Radiological effluent level (Ci/cc) meet any of the following for greater than 60 minutes:
> 1.2E-4 NTR Noble Gas Stack Monitor
> 1.2E-4 NTR Particulate Stack Monitor
> 1.2E-0 from any reactor facility effluent Noble Gas sample
> 2.4E-2 from any reactor facility effluent Halogen sample
> 1.2E-6 from any reactor facility effluent Particulate sample
> 1.2E-4 from any reactor facility effluent Particulate sample Actual or projected radiation levels at the site boundary of 0.2 mSv/hour deep dose equivalent (20 mrem/hour) for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or 1.0 mSv (100 mrem) to the thyroid (committed dose equivalent)
Security Conditions Security breach affecting the reactor facility SA1 Security breach affecting a reactor facility 5.2.1 RA1 Technical Basis The RA1 threshold values are directly related to the ANSI/ANS-15.16-2015 initiating condition values.
For the purpose of event declaration, direct measurement by survey instrument adjusted for exposure period is considered equivalent to an isotopic sample and analysis (where the determination of actual DDE and CEDE would not be timely).
5.2.2 RA2 Technical Basis The RA2 threshold values are directly related to the ANSI/ANS-15.16-2015 initiating condition values.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 22 of 39 For the purpose of event declaration, direct measurement by survey instrument adjusted for exposure period is considered equivalent to an isotopic sample and analysis (where the determination of actual DDE would not be timely).
CDE thyroid is determined by portable air sample and gross count adjustment for I-131 source term assumptions.
5.2.3 RA3 Technical Basis Per ANSI/ANS-15.16, it is expected that licensees will determine the relationship of the EAL dose levels at the site boundary to instrumentation readings and/or safety analysis accident conditions for their specific facilities.
NTR Vent Stack Noble Gas Monitor instrument range is 1E-06 to 1E+01 NTR Vent Stack Particulate Monitor instrument range is 2E-11 to 2E-04 Refer to Appendix 3 for the calculations supporting the threshold values for RA3.
5.2.4 SA1 Technical Basis The SA1 security breach threshold is based on the ANSI/ANS-15.16-2015 initiating condition wording and includes physical attacks and verification of bomb placement or sabotage directly affecting a reactor facility.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 23 of 39 6
EMERGENCY PLANNING ZONEs (EPZs)
Planning Standard (ANSI/ANS-15.16 Section 3.6 & NUREG-0849 Section 6.0)
As part of emergency planning, the reactor licensee or owner/operator of a facility that identifies radiological emergencies that result in off-site plume exposures exceeding 10 mSv deep dose (1 rem whole body) or 50 mSv (5 rem) thyroid shall identify an EPZ.
The postulated radioactive releases from credible accidents provide the basis for determining the need for an EPZ. The EPZ size depends on the distance at which the protective actions are calculated to be warranted. As an alternative to performing such calculations, the EPZ sizes in Table 2 may be adopted according to the power level. Table 2 is based upon highly conservative dose calculations that are generically applicable to research reactors.
6.1 NTR EPZ Per the NTR Safety Analysis Report Section 1.1, the NTR is licensed to operate at power levels not in excess of 100 kW (thermal).
Thus, based upon ANSI/ANS-15.16-2015 Section 3.6 and Table 2, the applicable EPZ for NTR is the operations boundary for the reactor facility.
The NTR operations boundary is established 6.2 GETR, VBWR, and EVESR EPZs The other three reactor facilities are in a defueled SAFSTOR status with the spent fuel no longer remaining on site.
Since the emergency planning requirements for these facilities are deferred to this VNC Regulatory Guide 2.6 emergency plan, their EPZ is based on the same specification as the NTR.
GETR, VBWR, and EVESR operations boundaries are established as their respective reactor containment enclosure.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 24 of 39 7
EMERGENCY RESPONSE Planning Standard (ANSI/ANS-15.16 Section 3.7 & NUREG-0849 Section 7.0)
Emergency response measures shall be identified for each emergency. These response measures should be related to the emergency class and action levels that specify what measures are to be implemented.
7.1 Activation of Emergency Organizations Site Emergency Procedures (SEPs) are established for notification and mobilization of emergency response personnel.
7.1.1 Notification of Onsite Personnel and Mobilization of the ERO Notification of onsite personnel occurs each time an emergency classification level is declared by the Emergency Director (initial event declaration and any escalation) via recognizable alarms and/or public address announcement Notification and mobilization of the VNC ERO is described in section 3.1.
7.1.2 Notification and Mobilization of the Offsite Response Organizations (ORO)
When an emergency classification level is declared or upgraded, initial notifications are made to continually staffed ORO warning points.
Notification and mobilization of federal and state agency response personnel is performed in accordance with their applicable emergency plans and procedures.
- 1. State Agencies (Cal OES)
Cal OES is notified within (1) hour of an event declaration (initial or an escalation).
- 2. Nuclear Regulatory Commission (NRC)
The NRC is notified immediately after notification of Cal OES and not later than one (1) hour after event declaration (initial or an escalation).
7.1.3 Notification Message Content The notification message provides the following information as applicable to the event:
Location of incident Emergency Classification Level Time and date the emergency was declared Event description (type)
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 25 of 39 Statement that no offsite protective actions are required The type and quantity of radionuclides released or expected to be released Name, title and telephone number of caller Understanding of the notification information by warning point personnel is verified at the end of the communication. Name, title and contact number of the VNC communicator is provided to enable the offsite agencies to verify the authenticity of the notification if desired.
7.2 Assessment Actions 7.2.1 Plant Parameters and Corresponding Emergency Classification Recognizable EAL thresholds have been developed in accordance with Regulatory Guide 2.6 and the NRC endorsed methodology in ANSI/ANS-15.16-2015 (refer to section 5).
EAL technical bases document the VNC site specific indications and parameters used to determine the thresholds that correlate to a particular emergency classification level (refer to section 5).
7.2.2 Onsite Accident Assessment Capabilities On-site capabilities and resources are available to provide information for accident assessment throughout the course of an event. Data will be obtained from in-place radiation monitors, portable instrumentation, and from observation and measurement by specific emergency teams.
Radiological instrumentation readings and sampling are used to project dose rates at the Site Boundary, and to determine the integrated dose received for events involving a release of radioactivity. Site emergency procedures address calculating accumulated or projected dose.
7.3 Corrective Actions VNC has strategies for mitigation of designated emergencies (such as radiological, fire, security threat, and other hazards) and has equipment available to be used in those strategies/mitigative actions.
The Emergency Director is responsible for assessing the need for and directing mitigation activities such as deactivation of process systems or restoration of disabled equipment needed to mitigate the consequences of an emergency. Additional assistance may be provided by other ERO positions upon arrival or via remote communications.
7.4 Protective Actions Preventive measures are implemented, to the extent practical, to prevent exposure of on-site personnel to radiological hazards; and in the event that prevention techniques fail, protective measures are in place to minimize the effects of such emergencies.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 26 of 39 Protective measures are taken by ERO personnel and any support organization personnel called to the site. Initial actions to protect non-emergency team personnel may involve evacuation from facilities followed by search for and rescue of missing persons, medical treatment, decontamination, and other actions judged appropriate by the Emergency Director dependent on existing conditions.
7.4.1 Personnel Evacuation from Immediate Area Personnel may be evacuated from an area affected by an emergency or moved to areas controlled for safety purposes. The evacuation is initiated by broadcasting instructions Reports of missing persons are relayed to the Emergency Director for appropriate search and rescue action.
7.4.2 Contamination Control Measures In response to an emergency involving a potential release of radioactive material, it is assumed that a release has occurred. The ERO establishes access controls to the area (such as rope/tape barriers, building access points, postings, control point watches, periodic announcements, etc.), determines whether radioactive contamination is present by survey, and takes appropriate steps to limit personnel exposure to and the spread of radioactive contamination. Area contamination information is provided to the Emergency Director and tracked by the ERO.
Emergency workers are protected from contamination by protective clothing available in emergency supply lockers. In order to protect emergency workers in areas of radioactive airborne contamination, self-contained breathing apparatuses (SCBA) or filtered respirators are available for use as appropriate.
Contaminated individuals are treated and decontaminated in isolated areas.
7.4.3 Personnel Decontamination/First Aid Individuals are surveyed and then decontaminated as necessary. If an individual is contaminated and injured, the order of decontamination/first aid administration is dependent on the severity of the contamination and injury. The criteria for deciding the order is that which is least detrimental to the overall health of the individual.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 27 of 39 7.4.4 Emergency Exposure Control and Guidelines Identification and control of radiation areas is performed the same as described in Section 7.4.2 for radioactive contamination. Measures and criteria for radiation, high radiation and locked high radiation areas encountered during a declared emergency are established the same as those used during normal operations as much as possible.
Direct exposures of emergency workers are monitored by remote area monitoring (RAM) devices, portable survey instruments, and by the individuals own personal monitoring devices (such as electronic dosimeters). A supply of electronic dosimeters that can be set to alarm for dose and dose rate values are maintained on site for emergency worker use.
Personnel exposure information is provided to the Emergency Director and tracked by the ERO.
Emergency exposure guidelines for emergency workers, consistent with EPA 400-R 001, PAG Manual: Protective Action Guides and Planning Guidance for Radiological Incidents, Table 3-1, "Emergency Worker Guidelines," have been established as follows:
Guideline Activity Condition 5 rem All occupational exposures All reasonably achievable actions have been taken to minimize dose.
10 rema Protecting critical infrastructure necessary for public welfare (e.g., a power plant)
Exceeding 5 rem unavoidable and all appropriate actions taken to reduce dose.
Monitoring available to project or measure dose.
25 rem Lifesaving or protection of large populations Exceeding 5 rem unavoidable and all appropriate actions taken to reduce dose.
Monitoring available to project or measure dose.
>25 rem Lifesaving or protection of large populations All conditions above and only for people fully aware of the risks involved.
a For potential doses >5 rem (50 mSv), medical monitoring programs should be considered.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 28 of 39 8
EMERGENCY FACILITIES AND EQUIPMENT Planning Standard (ANSI/ANS-15.16 Section 3.8 & NUREG-0849 Section 8.0)
The emergency plan should briefly describe the emergency facilities, types of equipment and their location.
8.2 Assessment Facilities The reactor facilities are monitored by area radiation monitors (ARMs) and effluent radiation (stack) monitors as required by their technical specifications. Radiation monitors with remote readouts permit continuous assessment in some areas.
Other monitoring devices are utilized to identify off-normal conditions, such as smoke detectors, fire and flood alarms, and onsite and offsite seismic and meteorological indicators. Several of these devices activate alarms locally and/or in the for immediate response and assessment.
Portable survey and personnel monitoring instruments are maintained throughout the site and are available for use during an emergency.
Sampling equipment and a counting laboratory are available on site and offsite for specific radionuclide identification and analysis.
8.3 First Aid and Decontamination Equipment The site contains numerous areas where radioactive materials are used. Consequently, there are numerous areas where contaminated injured individuals may be relocated for first aid administration and decontamination. On site company vehicles are available for transportation.
First aid supplies, stretchers, industrial showers, and AEDs are available at the site.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 29 of 39 GEH will provide a radiation monitor to assist in the control and cleanup of contamination of ambulance and offsite medical facilities used when treating contaminated injured personal transported from the site as necessary.
8.4 Communications Equipment 8.4.1 Land Line Telephone A standard telephone system is installed in every major building on site. The CAS contains phones with several extensions and conference call capability.
8.5 Contingency Planning Procedures include instructions for consideration in case the emergency renders the ECC or equipment employed during the response unusable. The VNC site contains several facilities that can be designated response locations should the ECC be unavailable. First-aid, personnel protective clothing, radiological, fire-fighting, etc. equipment and resources are maintained throughout the site such that access restrictions to a particular area would not likely result in the inability to perform necessary response activities.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 30 of 39 Mutual aid agreements between offsite support agencies provides assurance that fire, medical and law enforcement resources would be available when called upon.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 31 of 39 9
RECOVERY Planning Standard (ANSI/ANS-15.16 Section 3.9 & NUREG-0849 Section 9.0)
This element of the emergency plan should describe the criteria for restoring the reactor facility to a safe status including reentry into the reactor building or portions of the facility that-may have been evacuated because of the accident. The operations to recover from most severe accidents will.be complex and depend on the actual conditions at the facility. It is not practicable to plan detailed recovery actions for all conceivable situations.
9.1 Reentry During an emergency, immediate actions are directed toward limiting the consequences of the accident to afford maximum protection to personnel onsite. Once corrective measures have been taken and effective control of the facility has been reestablished, a more methodical approach to reentry is taken. Reentry into two separate categories:
Reentry during the emergency phase of an accident is performed to save a life, control a release of radioactive material, prevent further damage to or restore equipment. If necessary, this category of reentry may be performed using emergency exposure limits. Briefings, rather than written procedures, may be used when making these reentries.
All reentry activities conducted during the emergency are authorized by the Emergency Director and coordinated by Incident Command.
Reentry during the recovery phase of an accident is performed using normal occupational exposure limits. Either normal procedures or procedures developed specifically for each reentry are used to control post-emergency activities.
Reentry activities during the recovery phase are authorized by a Recovery Director or the VNC Manager, and coordinated by the recovery personnel directing and performing the reentry.
9.2 Recovery During a declared emergency, a point will be reached when the facility will be restored to a stable condition. The Emergency Director will determine when there is no longer a need to keep the ERO activated and the site can return to a normal organization for control.
The extent and nature of the corrective and protective measures and the extent of facility recovery will depend on the remaining conditions, if any, and the status of site areas and equipment. The general goals for recovery are:
An orderly evaluation of the cause and effect of the event and the implementing of actions to prevent recurrence of the incident.
A planned approach for maintaining the facility in a stable condition by obtaining the appropriate manpower, materials, and equipment needed to accomplish that end.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 32 of 39 An evaluation of the emergency radiation exposure records for all on-site emergency response personnel involved in the incident.
A planned approach to ensure that further radiation exposures and contamination control are restored under 10 CFR 20 requirements and are in keeping with the ALARA program.
Procedures have been developed for the systematic transition from the declared state of emergency to recovery and termination.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 33 of 39 10 MAINTAINING EMERGENCY PREPAREDNESS Planning Standard (ANSI/ANS-15.16 Section 3.10 & NUREG-0849 Section 10.0)
The emergency plan shall describe the elements necessary for maintaining an acceptable state of emergency preparedness. A description shall be provided of how the effectiveness of the emergency plan will be maintained, including training, review, and update of the emergency plan and associated implementing procedures along with maintenance and inventory of equipment and supplies that would be used in emergencies. Frequent coordination with emergency support organizations should also be maintained to ensure the necessary training and the efficient use of their capabilities.
10.1 Training and Drills 10.1.1 Training ERO personnel receive the appropriate level of site access, radiological, communications systems, facility evacuation, and position specific training. The training for ERO personnel is primarily developed from the position specific responsibilities and tasks as defined in this plan and the site emergency procedures.
Emergency response and other personnel in the following categories receive knowledge and/or performance based training initially and annual retraining thereafter:
- 1. Emergency Directors This position receives training to maintain proficiency on the topics listed below:
Event Classification / Emergency Action Levels Event Notification and Communications Accident Assessment and Mitigation Protective Actions / Emergency Exposure Control
- 2. Accident Assessment Personnel Accident assessment activities are performed by Emergency Directors, Facilities Managers (as applicable), and GEH operations, radiological, security and maintenance managers as a function of their areas of expertise and ERO roles.
- 3. Radiological Monitoring and Analysis Teams Radiological monitoring personnel will receive training for the actions they will be expected to perform during an emergency as part of their training. The following general topics will be included in the training:
Equipment and Equipment Checks Emergency Communications
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 34 of 39 Radiological Release Surveys and Sampling Emergency Exposure Control
- 4. First Aid and Rescue Personnel A number of site employees are trained in first aid.
Basic search and rescue activities may be performed by ERO personnel as part of event response.
- 5. Medical Support Personnel VNC does not maintain medical support personnel, such as a site nurse on staff.
- 6. Police, Security, Ambulance and Fire-Fighting and Other Personnel a) Training of site security personnel is controlled by the VNC Security Plan.
b) Building Emergency Team members receive initial training and annual reviews in respiratory protection, radiological protection, first aid, fire protection and emergency support as appropriate for their assigned responsibilities.
c) The Site Fire Chief is responsible for fire protection training of designated personnel assigned to the site fire team, which is controlled outside this emergency plan as defined by the site fire protection program.
d) Training is offered to the offsite support organizations that may be called upon to provide assistance in the event of an emergency (i.e., local law enforcement, fire-fighting, rescue, medical services, ambulance).
The training made available is designed to acquaint the participants with the special characteristics of VNC (e.g. potential radiation and radiological contamination areas), notification procedures, and their expected roles. Organizations that must enter the site also receive instructions as to the identity (by position and title) of those VNC persons who will control their support activities.
e) Badged site personnel who are not part of the ERO are instructed in reporting and responding to alarms.
10.1.2 Conduct of Drills Drills are conducted annually to provide supervised instruction, training and practice opportunities for ERO members and are executed as realistically as is reasonably possible.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 35 of 39 Written scenarios, prepared in advance, govern the conduct of annual drill and include the following as applicable:
General Information - A section containing the scope of the scenario, time period, place(s), and participating organizations.
Timeline - A section containing the time schedule of initiating events.
Messages - A section for plant data, injects, messages, and symptomology cards.
Onsite Radiological Data - A section for area radiation maps and display system snapshots, if warranted by the scenario events.
Objectives - A section containing a table of performance objectives expected to be demonstrated during the scenario.
Participant/Controller/Evaluator/Observer Instructions - as applicable to the drill.
Smaller response proficiency drills, such as evacuation drills, may be performed in addition to the larger scope annual drill in each occupied building at VNC.
At least every two years, a drill shall be offered that contains provisions for coordination with off-site emergency personnel and should test, at a minimum, the communication links and notification procedures with those off-site agencies and support organizations.
10.1.3 Critique of Drills Following the observation of drills, a critique is conducted to evaluate areas such as personnel performance, response procedure processes, and facility and equipment adequacy and identify issues. Specifically, the critique is performed as soon as possible following the conclusion of a drill using preselected performance objectives that are evaluated against measurable demonstration criteria.
A written critique report is prepared a drill to document whether the objectives were successfully demonstrated. Failed or degraded performance objectives are entered into the corrective action program (CAP). Failed or degraded demonstration criteria, improvement items and recommendations are dispositioned within the report and may be entered into the CAP.
10.2 Plan Review and Update 10.2.1 Responsibility for the Plan The Manager, VNC is the senior GEH employee on site with overall authority for site operations. This authority includes the responsibility for overall emergency preparedness activities at VNC.
The Manager, RC & EHS, is responsible for administering the program by coordinating and planning radiological emergency preparedness, updating the emergency plan, and coordinating plans with other appropriate organizations.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 36 of 39 10.2.2 Review and Update The Emergency Plan will be reviewed to be current on a biennial basis, and updated if necessary. Any changes due to regulatory revisions, issues identified by drills and exercises, or other updates will be incorporated into the Emergency Plan.
Agreements with supporting organizations will be reviewed on a biennial basis, and updated if necessary. Changes to agreements may be coordinated with the biennial review of the Emergency Plan. VNC maintains the following support agreements:
- 1. Faulk Northern California - Applicable to Sections 3.3.1, First Aid Assistance, and 3.3.3, Ambulance Service
- 2. The Hospital Committee for the Livermore-Pleasanton Areas - Applicable to Section 3.3.2, Medical Treatment Facilities
- 3. Alameda County Fire Department - Applicable to Section 3.3.4, Firefighting Assistance
- 4. Alameda County Sheriff's Office - Applicable to Section 3.3.5, Police Assistance Emergency plan implementing and administrative procedures are reviewed biennially or when revised as needed.
Changes will be processed in accordance with 10 CFR 50.54(q) requirements and distributed per site procedures.
10.3 Maintenance and Inventory of Emergency Equipment, Instrumentation, and Supplies In addition to supplies of normal use equipment and instruments, emergency kits are maintained at VNC. Annual inventories and quarterly surveillances are performed to verify supplies and kit contents, and inspect and operationally check emergency use equipment/instruments. The inventories will utilize the corrective action program to document follow-up action items that correct any deficiencies discovered. Sufficient reserves of instruments and equipment are maintained to replace those removed from emergency kits or lockers for calibration or repair.
Requirements to operationally check emergency equipment and instruments prior to use, if needed, are contained in site procedures.
Requirements to calibrate emergency equipment and instruments are specified in site procedures.
Portable radiation monitoring instruments are calibrated upon initial acquisition, after major maintenance and at least annually. Radiation Protection is responsible for the maintenance and storage of radiological equipment and instruments.
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 37 of 39 Appendix 1 - Regulatory and Developmental References
- 1. 10 CFR 20, Standards for Protection Against Radiation
- 2. 10 CFR 50.54, Conditions of Licenses
- 3. 10 CFR 50 Appendix E, Emergency Planning and Preparedness for Production and Utilization Facilities
- 4. Regulatory Guide 2.6, Emergency Planning for Research and Test Reactors, Revision 2
- 5. ANSI/ANS-15.16-2015, Emergency Planning for Research Reactors
- 6. NUREG-0849, Standard Review Plan for the Review and Evaluation of Emergency Plans for Research and Test Reactors, October 1983
- 7. EPA 400/R-17/001, PAG Manual: Protective Action Guides and Planning Guidance for Radiological Incidents, January 2017
- 8. General Electric Nuclear Test Reactor Safety Analysis Report, June 2000
- 9. NRC Letter SNM-960 Amendment 5, 12/20/90
- 10. GEH Memo, Evaluation that a VNC Radiological Emergency Plan is not Required for Radioactive Material Authorized by the State of California, 03/08/18
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 38 of 39 Appendix 2 - Emergency Plan Implementing Procedures Response Procedures REP 1.1, ECC ERO Activation and Operations REP 1.2, REP Emergency Classification and Notifications REP 1.3, REP Radiological Monitoring and Response REP 1.3, REP Protective Actions REP 1.4, REP Response Actions Maintenance and Administrative Procedures REP 2.1, Implementation, Maintenance and Review of REP Documents REP 2.2, Equipment Important to Emergency Response REP 2.3, REP Training and Qualification CP-28-116, REP Drills and Exercises
Security Related and Proprietary Information-Withhold from Public Disclosure Pursuant to 10 CFR 2.390 VNC Radiological Emergency Plan June 9, 2021 Security-Related and Proprietary Information - Withhold from Public Disclosure per 10CFR2.390 Page 39 of 39 Appendix 3 - EAL Technical Bases for Effluent Releases Method: 10 CFR 20 effluent concentration limits, representative of a 50 mrem/yr dose, are adjusted to an equivalent concentration limit for the EAL site boundary threshold value in mr/hr.
The site boundary EAL concentration limit is back-calculated to an effluent stack release rate using the limiting SAR X/Q dispersion factor and stack flow rate.
10 CFR 20 Concentration Limit
(µCi/cc)
RU3 Site Boundary Release Concentration
(µCi/cc)
RU3 NTR Stack Release Rate
(µCi/sec)
RU3 NTR Stack Release Concentration
(µCi/cc) 10 CFR 20 Unknown*
1.00E-12 7.01E-10 2.02E+01 2.37E-05 Noble Gas**
Ar-41 1.00E-08 7.01E-06 2.02E+05 2.37E-01 Halogen**
I-131 2.00E-10 1.40E-07 4.03E+03 4.74E-03 Alpha Particulate**
Np-237 1.00E-14 7.01E-12 2.02E-01 2.37E-07 Beta-Gamma Particulate**
1.00E-12 7.01E-10 2.02E+01 2.37E-05 10 CFR 20 Concentration Limit
(µCi/cc)
RA3 Site Boundary Release Concentration
(µCi/cc)
RA3 NTR Stack Release Rate
(µCi/sec)
RA3 NTR Stack Release Concentration
(µCi/cc) 10 CFR 20 Unknown*
1.00E-12 3.51E-09 1.01E+02 1.19E-04 Noble Gas**
Ar-41 1.00E-08 3.51E-05 1.01E+06 1.19E+00 Halogen**
I-131 2.00E-10 7.01E-07 2.02E+04 2.37E-02 Alpha Particulate**
Np-237 1.00E-14 3.51E-11 1.01E+00 1.19E-06 Beta-Gamma Particulate**
1.00E-12 3.51E-09 1.01E+02 1.19E-04 Calculation Constants 10 CFR 20 Effluent Concentration Dose Basis (mrem/yr):
50 10 CFR 20 Effluent Concentration Dose Basis (mrem/hr):
5.70E-03 EAL RU3 Limit (mr/hr):
4 EAL RA3 Limit (mr/hr):
20 Limiting X/Q* (sec/cc):
3.48E-11 NTR Bldg 105 Stack Flow Rate* (cfm):
1800 Conversion Factor (cc/sec per cfm):
471.95 NTR Bldg 105 Stack Flow Rate (cc/sec): 8.50E+05
- 10 CFR 20 limit for unlisted (unknown) radionuclide with decay mode other than alpha emission or spontaneous fission and with radioactive half-life greater than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
- Values taken from NTR SAR Section 6.4