Westinghouse Non-Proprietary Class 3 C-1 WCAP-18795-NP December 2022 Revision 0 APPENDIX C CHARPY V-NOTCH PLOTS FOR EACH CAPSULE INCLUDING BASELINE DATA USING SYMMETRIC HYPERBOLIC TANGENT CURVE-FITTING METHOD C.1 METHODOLOGY Contained in Table C-1 are the upper-shelf energy (USE) values that are used as input for the generation of the Charpy V-notch plots using CVGRAPH, Version 6.02. The definition for USE is given in ASTM E185-82 [C-1],

Section 4.18, and reads as follows:

upper shelf energy level - the average energy value for all Charpy specimens (normally three) whose test temperature is above the upper end of the transition region. For specimens tested in sets of three at each test temperature, the set having the highest average may be regarded as defining the upper shelf energy.

Westinghouse reports the average of all Charpy data ( 95% shear) as the USE, excluding any values that are deemed outliers using engineering judgment. Hence, the Capsule N USE values reported in Table C-1 were determined by applying this methodology to the Charpy data tabulated in Table 5-1 through Table 5-5 of this report. USE values documented in Table C-1 for the unirradiated material, as well as for Capsules V, T, R, and P, were also determined by applying the methodology described above to the Charpy impact data reported in WCAP-8193 [C-2] and WCAP-14613 [C-3]. The USE values reported in Table C-1 were used in the generation of the Charpy V-notch curves.

The lower-shelf energy values were fixed at 2.2 ft-lb for all cases. The lower-shelf lateral expansion values were fixed at 1.0 mil to be consistent with the previous capsule analysis. Similarly, the upper-shelf energy must also be fixed for curve-fitting the Charpy V-notch (CVN) Energy data using the values reported in Table C-1.

However, the upper-shelf lateral expansion is not fixed in CVGRAPH.

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-2 WCAP-18795-NP December 2022 Revision 0 Table C-1 Upper-Shelf Energy Values Fixed in CVGRAPH(1)

Material Unirradiated Capsule V Capsule T Capsule R Capsule P Capsule N (ft-lb)

(ft-lb)

(ft-lb)

(ft-lb)

(ft-lb)

(ft-lb)

Lower Shell Forging D (Heat # 22642)

(Tangential Orientation) 147.7 163.3 133.0 127.3 128.8 125.0 Lower Shell Forging D (Heat # 22642)

(Axial Orientation) 106.2 115.3 92.8 98.5 94.3 89.0 Intermediate Shell to Lower Shell Circumferential Weld -

Seam W3 (Heat # 2721) 103.3 97.2 94.8 91.0 98.5 95.0 Heat Affected Zone (HAZ) Material 114.0 122.0 98.7 88.3 96.0 82.0 Correlation Monitor Material (CMM) 120.4 101.8 87.7 77.0 96.0 79.0 Note:

1.

These values are calculated as an average of all in-family data points with a shear 95%, consistent with ASTM E185-82 [C-1],

unless otherwise noted.

CVGRAPH, Version 6.02 plots of all surveillance data are provided in this appendix, on the pages following the reference list.

C.2 REFERENCES C-1 ASTM E185-82, Standard Practice for Conducting Surveillance Tests for Light-Water Cooled Nuclear Power Reactor Vessels, American Society for Testing and Materials, 1982.

C-2 Westinghouse Report, WCAP-8193, Rev. 0, Northern States Power Co. Prairie Island Unit No. 2 Reactor Vessel Radiation Surveillance Program, September 1973.

C-3 Westinghouse Report, WCAP-14613, Rev. 2, Analysis of Capsule P from the Northern States Power Company Prairie Island Unit 2 Reactor Vessel Radiation Surveillance Program, February 1998.

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-3 WCAP-18795-NP December 2022 Revision 0 C.3 CVGRAPH VERSION 6.02 INDIVIDUAL PLOTS

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-4 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-5 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-6 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-7 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-8 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-9 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-10 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-11 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-12 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-13 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-14 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-15 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-16 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-17 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-18 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-19 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-20 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-21 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-22 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-23 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-24 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-25 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-26 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-27 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-28 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-29 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-30 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-31 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-32 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-33 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-34 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-35 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-36 WCAP-18795-NP December 2022 Revision 0

      • This record was final approved on 12/14/2022, 8:08:16 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-37 WCAP-18795-NP December 2022 Revision 0