– Correction of Amendment Nos. 319 and 264 Regarding Revision to Technical Specifications to Adopt Risk-Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times – RITSTF
ML23018A004
Person / Time
Site: Hatch  
(DPR-057, NPF-005)
Issue date: 01/24/2023
From: John Lamb
Plant Licensing Branch II
To: Gayheart C
Southern Nuclear Operating Co
Kalathiveettil, D
References
EPID L-2022-LLA-0100
Download: ML23018A004 (1)


Text

January 24, 2023 Ms. Cheryl A. Gayheart Regulatory Affairs Director Southern Nuclear Operating Co., Inc.

3535 Colonnade Parkway Birmingham, AL 35243

SUBJECT:

EDWIN I. HATCH NUCLEAR PLANT, UNITS 1 AND 2 - CORRECTION OF AMENDMENT NOS. 319 AND 264 REGARDING REVISION TO TECHNICAL SPECIFICATIONS TO ADOPT RISK-INFORMED COMPLETION TIMES TSTF-505, REVISION 2, PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INIATIVE 4b (EPID L-2021-LLA-0199)

Dear Ms. Gayheart:

On December 22, 2022, the U.S. Nuclear Regulatory Commission (NRC) issued Amendment Nos. 319 and 264 (Agencywide Documents Access and Management System (ADAMS)

Accession No. ML22297A146) to Renewed Facility Operating Licenses (RFOLs) DPR-57 and NPF-5 for the Edwin I. Hatch Nuclear Plant (Hatch), Units 1 and 2, respectively.

The amendments revised Hatch, Units 1 and 2, Technical Specifications (TSs) requirements to permit the use of risk-informed completion times for actions to be taken when limiting conditions for operation are not met. The changes were based on Technical Specifications Task Force (TSTF) Traveler TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times -

RITSTF Initiative 4b.

An administrative error on the part of the NRC staff was made on the attachments with the Remove and Insert TS pages. Since there were numerous editorial changes with the amendments, this caused page numberings to be changed. For Hatch, Unit 1, new TS pages 3.3-30a, 3.7-5a, and 5.0-19a are provided with revision bars indicating the line corrections. For Hatch Unit 2, TS pages 3.3-30a, 3.3-54a, 3.7-5a, 3.8-4, 3.8-5, and 5.0-19a are provided with revision bars indicating the line corrections. The administrative errors involved an improper indication that the subject TS pages were removed, when the line items for certain TS pages.,

should have ---- in the Remove column rather than the TS page numbers as these were new TS pages.

A typographical error on the part of Southern Nuclear Operating Co., Inc. (SNC) was made in the footer of Hatch, Unit 2, TS page 3.7-2, as described in a letter dated January 20, 2023 (ML23020A932). The amendment issued on December 22, 2022, for Hatch, Unit 2, TS page 3.7-2 footer read 5HATCH UNIT 2. The corrected footer would read HATCH UNIT 2.

An administrative error on the part of SNC was made on Hatch, Unit 2, TS page 3.6-8 for the first Completion Time for Required Action A.3 as described in the letter dated January 20, 2023.

The words for isolation was inadvertently omitted in the clean TS page.

By letter dated October 26, 2021 (ML21300A153), SNC requested NRC to include for isolation in Hatch, Unit 2, TS page 3.6-8 to state:

Once per 31 days following isolation for isolation devices outside primary containment Consistent with NRC staff guidance dated January 16, 1997 (ML103260096) and based on the NRCs policy established by SECY-96-238, these errors can be corrected by a letter to the licensee from the NRC staff. These changes do not affect the NRC decision approving amendment Nos. 319 and 264 and do not affect the No Significant Hazards Consideration as published in the Federal Register.

Enclosed please find (1) the corrected Hatch, Units 1 and 2, attachments with the Remove and Insert TS pages, (2) the corrected Hatch, Unit 2, TS page 3.7-2, and (3) the corrected Hatch, Unit 2, TS page 3.6-8.

If you have any questions, please contact me at 301-415-3100 or John.Lamb@nrc.gov.

Sincerely,

/RA/

John G. Lamb, Senior Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos.: 50-321 and 50-366

Enclosure:

As stated cc:

Listserv

ATTACHMENT TO LICENSE AMENDMENT NO. 319 EDWIN I. HATCH NUCLEAR PLANT, UNIT NO. 1 RENEWED FACILITY OPERATING LICENSE NO. DPR-57 DOCKET NO. 50-321 Replace the following pages of the License and the Appendix A, Technical Specifications (TSs) with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.

Remove Pages Insert Pages License License 4

4 TSs TSs 1.3-11 1.3-11 1.3-12 1.3-12 1.3-13 3.1-17 3.1-17 3.3-1 3.3-1 3.3-1a 3.3-2 3.3-2 3.3-28 3.3-28 3.3-29 3.3-29 3.3-30 3.3-30 3.3-30a 3.3-31 3.3-31 3.3-32 3.3-32 3.3-33 3.3-33 3.3-35 3.3-35 3.3-36 3.3-36 3.3-36a 3.3-47 3.3-47 3.3-48 3.3-48 3.3-51 3.3-51 3.3-52 3.3-52 3.3-53 3.3-53 3.3-54 3.3-54 3.5-1 3.5-1 3.5-2 3.5-2 3.5-2a 3.5-10 3.5-10 3.6-5 3.6-5 3.6-7 3.6-7 3.6-8 3.6-8

Remove Pages Insert Pages TSs TSs 3.6-9 3.6-9 3.6-10 3.6-10 3.6-11 3.6-11 3.6-12 3.6-12 3.6-25 3.6-25 3.6-26 3.6-26 3.6-27 3.6-27 3.6-28 3.6-28 3.6-29 3.6-29 3.6-30 3.6-30 3.7-1 3.7-1 3.7-2 3.7-2 3.7-3 3.7-3 3.7-4 3.7-4 3.7-5 3.7-5 3.7-5a 3.8-2 3.8-2 3.8-3 3.8-3 3.8-4 3.8-4 3.8-4a 3.8-4b 3.8-5 3.8-5 3.8-6 3.8-6 3.8-26 3.8-26 3.8-27 3.8-27 3.8-27a 3.8-40 3.8-40 3.8-41 3.8-41 5.0-19 5.0-19 5.0-19a

ATTACHMENT TO LICENSE AMENDMENT NO. 264 EDWIN I. HATCH NUCLEAR PLANT, UNIT NO. 2 RENEWED FACILITY OPERATING LICENSE NO. NPF-5 DOCKET NO. 50-366 Replace the following pages of the License and the Appendix A, Technical Specifications (TSs) with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.

Remove Pages Insert Pages License License 4

4 TSs TSs 1.3-11 1.3-11 1.3-12 1.3-12 1.3-13 3.1-17 3.1-17 3.3-1 3.3-1 3.3-1a 3.3-2 3.3-2 3.3-28 3.3-28 3.3-29 3.3-29 3.3-30 3.3-30 3.3-30a 3.3-31 3.3-31 3.3-32 3.3-32 3.3-33 3.3-33 3.3-35 3.3-35 3.3-36 3.3-36 3.3-36a 3.3-47 3.3-47 3.3-48 3.3-48 3.3-51 3.3-51 3.3-52 3.3-52 3.3-53 3.3-53 3.3-54 3.3-54 3.3-54a 3.5-1 3.5-1 3.5-2 3.5-2 3.5-2a 3.5-3 3.5-3 3.5-11 3.5-11 3.6-5 3.6-5

Remove Pages Insert Pages TSs TSs 3.6-7 3.6-7 3.6-8 3.6-8 3.6-9 3.6-9 3.6-10 3.6-10 3.6-11 3.6-11 3.6-12 3.6-12 3.6-25 3.6-25 3.6-26 3.6-26 3.6-27 3.6-27 3.6-28 3.6-28 3.6-29 3.6-29 3.6-30 3.6-30 3.7-1 3.7-1 3.7-2 3.7-2 3.7-3 3.7-3 3.7-4 3.7-4 3.7-5 3.7-5 3.7-5a 3.8-2 3.8-2 3.8-3 3.8-3 3.8-4 3.8-4a 3.8-4b 3.8-5 3.8-5a 3.8-5b 3.8-6 3.8-6 3.8-26 3.8-26 3.8-27 3.8-27 3.8-27a 3.8-40 3.8-40 3.8-41 3.8-41 5.0-19 5.0-19 5.0-19a

PCIVs 3.6.1.3 HATCH UNIT 2 3.6-8 Amendment No. 264 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

(continued)

A.2


NOTE-----------

Only applicable to main steam line.

Isolate the affected penetration flow path by use of at least one closed and de-activated automatic valve, closed manual valve, blind flange, or check valve with flow through the valve secured.

AND A.3


NOTES-----------

1. Isolation devices in high radiation areas may be verified by use of administrative means.
2. Isolation devices that are locked, sealed, or otherwise secured may be verified by administrative means.

Verify the affected penetration flow path is isolated.

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> OR In accordance with the Risk Informed Completion Time Program Once per 31 days following isolation for isolation devices outside primary containment AND Prior to entering MODE 2 or 3 from MODE 4 if primary containment was de-inerted while in MODE 4, if not performed within the previous 92 days, for isolation devices inside primary containment (continued)

RHRSW System 3.7.1 HATCH UNIT 2 3.7-2 Amendment No. 264 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME D.

Required Action and associated Completion Time of Condition A, B, or C not met.

D.1


NOTE---------

LCO 3.0.4.a is not applicable when entering MODE 3.

Be in MODE 3.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> E.

Both RHRSW subsystems inoperable for reasons other than Condition B.


NOTE------------------

Enter applicable Conditions and Required Actions of LCO 3.4.7 for RHR shutdown cooling made inoperable by RHRSW System.

E.1 Restore one RHRSW subsystem to OPERABLE status.

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> F.

Required Action and associated Completion Time of Condition E not met.

F.1 Be in MODE 3.

AND F.2 Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> 36 hours SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.1.1 Verify each RHRSW manual, power operated, and automatic valve in the flow path, that is not locked, sealed, or otherwise secured in position, is in the correct position or can be aligned to the correct position.

In accordance with the Surveillance Frequency Control Program

ML23018A004 OFFICE NRR/DORL/LPL2-1/PM NRR/DORL/LPL2-1/LA NRR/DORL/LPL2-1/BC NRR/DORL/LPL2-1/PM NAME JLamb KGoldstein MMarkley JLamb DATE 1/17/2023 01/23/2023 1/24/2023 1/24/2023