Technical Specification 5.6.8 A member of the STARS Alliance, LLC Callaway
- Diablo Canyon
- Palo Verde
- Wolf Creek Palo Verde Nuclear Generating Station 5871 S. Wintersburg Road Tonopah, AZ 85354 Mail Station 7636 Tel 623.393.5753 102-08524-MSC/CJS November 4, 2022 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Palo Verde Nuclear Generating Station Unit 1 Docket No. STN 50-528 Renewed Operating License No. NPF-41 23rd Refueling Outage Steam Generator Tube Inspection Report Attached please find the Palo Verde Nuclear Generating Station (PVNGS) Unit 1 Steam Generator Tube Inspection Report prepared and submitted by Arizona Public Service Company pursuant to Technical Specification Reporting Requirement 5.6.8. This report describes steam generator tube inspection and plugging results from the Unit 1 twenty-third refueling outage.
By copy of this letter, this submittal is being provided to the Nuclear Regulatory Commission (NRC) Region IV Administrator and the PVNGS Senior Resident Inspector.
No commitments are being made to the NRC by this letter.
Should you need further information regarding this submittal, please contact me at (623) 393-5753.
Sincerely, Matthew S. Cox Department Leader, Nuclear Regulatory Affairs MSC/CJS/cr
Enclosure:
Unit 1 - 23rd Refueling Outage Steam Generator Tube Inspection Report cc:
S. A. Morris NRC Region IV Regional Administrator D. Galvin NRC NRR Project Manager for PVNGS L. N. Merker NRC Senior Resident Inspector for PVNGS Cox, Matthew S(Z05628)
Digitally signed by Cox, Matthew S(Z05628)
Date: 2022.11.04 09:23:22 -07'00'
Enclosure Unit 1 - 23rd Refueling Outage Steam Generator Tube Inspection Report
UNIT 1 U1R23 ARIZONA PUBLIC SERVICE P. O. BOX 52034 PHOENIX, AZ 85072 Prepared by: Rachael Harley 10-10-2022 Reviewed by:
Approved by:
Commercial Service Date: 1-28-86 Harley, Rachael J(Z09624)
Digitally signed by Harley, Rachael J(Z09624)
Date: 2022.10.11 12:03:19 -07'00' Leaverton, Warren L(V59783)
Digitally signed by Leaverton, Warren L(V59783)
Date: 2022.10.11 12:23:42 -07'00' Bolf, Boris B(Z99978)
Digitally signed by Bolf, Boris B(Z99978)
Date: 2022.10.25 12:26:40 -07'00'
Table of Contents 1.0
SUMMARY
2.0 SCOPE OF EXAMINATIONS PERFORMED 3.0 ACTIVE DEGRADATION MECHANISMS 4.0 NDE TECHNIQUES UTILIZED 5.0 INDICATION
SUMMARY
6.0 TUBES PLUGGED 7.0 PLUG HISTORY 8.0 CONDITION MONITORING APPENDIX A - TUBE SUPPORT DIAGRAM, LEGEND, and ANALYSIS CODES APPENDIX B - SG 1
SUMMARY
DATA SHEETS APPENDIX C - SG 2
SUMMARY
DATA SHEETS APPENDIX D - PLI and PLP DATA SHEETS APPENDIX E - PLUG MAPS APPENDIX F - FORM NIS - 1
UNIT 1 STEAM GENERATOR EDDY CURRENT U1 R23 Refueling Outage 1.0 Summary This report is intended to satisfy the requirements of PVGS Technical Specifications 5.6.8 for the submittal of a Steam Generator Tube Inspection Report. The steam generator (SG) eddy current examination for the 23rd refueling outage in Unit 1 (U1R23) was conducted during April 2022.
Mode 4 entry was on May 10, 2022. The initial examination plan for both steam generators is listed in Table 1. This table summarizes the examinations performed for each of the various categories, examination types, extents, and the number of tubes or tube locations completed. This examination was a 100% full length tubing inspection.
The examinations resulted in a total of 12 tubes being plugged in SG 11, and 10 tubes being plugged in SG 12. A description of the previous plugging history for these replacement steam generators is contained in Appendix E.
2.0 Scope of Examinations Performed The original examination plan was developed based on the PVGS U1R23 Steam Generator Degradation Assessment (Intertek document number AIM 220411115-2Q-1, Revision 0 dated April 12, 2022). This document was developed per PVGS Procedure 81DP-9RC01 as required by NEI 97-06. In addition, possible damage mechanisms were reviewed along with the specific requirements set forth in Procedure 73TI-9RC01 and the PVGS Technical Specifications.
This original plan, along with the examinations performed as a result of bobbin indications noted, is summarized in Table 1 of this report. While a full length 100% bobbin inspection was performed, some tubes were acquired as partial lengths from both the hot leg and cold leg. This notable change was due to black sludge on the ID of the tubes. The sludge caused excessive wear on the probes and poor data quality when passed around both square bends. The decision was made to acquire partial lengths (candy cane) from both ends to preserve probe life and achieve improved data quality. Full length and partial length inspections are detailed in Table 1.
3.0 Active Degradation Mechanisms The only degradation noted during the examinations was determined to be wear. Section 8.0 contains further discussions relating to this mechanism. Table 2 summarizes the results into categories and Appendix B and C itemizes all indications reported.
4.0 NDE Techniques Utilized The following table documents the site validated and qualified techniques utilized during this outage:
BOBBIN Examinations Damage Mechanism Location ETSS NO QUAL STATUS Extended Applicability BC DET BC SIZE TECH Comment Wear BWs, VSs, ECs (not dented) 96004.1 R13 SITE VALIDATED Tube Proximity Y
Y Volt DIFF Note ARRAY Examinations Damage Mechanism Location ETSS NO QUAL STATUS Extended Applicability DET SIZE TECH Comment Wear BWs, ECs, VSs 11956.3 R2 11956.4 R2 QUALIFIED Wear at Dented Supports Y
Y X-Probe Note RPC Examinations Damage Mechanism Location ETSS NO QUAL STATUS Extended Applicability DET SIZE TECH Comment Wear BWs, ECs, VSs 96910.1 R11 QUALIFIED Wear at Dented Supports Y
Y X-Probe Note The U1R23 Degradation Assessment and associated site validation provides details for the qualification and use of the above techniques The eddy current examinations were performed by Westinghouse Electric Company using the Core Star OMNI 200 eddy current instrument. Westinghouse Anser software was utilized to acquire the data along with the Pegasys robotic manipulator. This robot was configured with a dual guide tube in each of the hot and cold legs.
The tubing was examined with Core Star manufactured bobbin coil probes and Zetec array style probes. The probe diameter utilized for all bobbin examinations was 0.610. Array probes were used for the characterization of non-quantifiable or distorted bobbin indications as well as to provide length measurements for wear.
Fiber optic cable was used from containment to the data acquisition room located at the PVGS North Annex (Building G). Primary and Secondary analysis, the Primary and Secondary Resolution
Analysts, Independent Review Analysts, and Data Management were located at the Westinghouse Waltz Mill facility in Pennsylvania. Westinghouse provided the data acquisition. Westinghouse and some subcontracted Anatec personnel provided primary data analysis. Anatec provided the secondary data analysis for array data.
Each individual from Westinghouse, and Anatec who performed data analysis was required to complete and pass a PVGS site specific Eddy Current Data Analysis Course as well as an associated performance and written examination. All individuals performing data analysis were also required to have Qualified Data Analyst (QDA) certification. Per 73TI-9RC01, all certification records are maintained in the Nuclear Information Records Management System.
5.0 Indication Summary A detailed listing of the location and measured sizes of all service induced indications recorded is included in Appendix B and C. A summary of these indication results is located in Table 2. In addition, Appendix A contains a reference drawing of steam generator support locations and report legend.
Appendix D contains a listing of the possible loose part (PLP) indications that were confirmed with an array examination. Note Section 8.0 for further discussion on the PLPs.
There were no indications that were identified as linear during this outage.
6.0 Tubes Plugged A summary of the tubes plugged is located in Table 2. Appendix E contains a map that details the plugged tube location along with the previously plugged tubes.
7.0 Plug History A summary of the number and percentage of tubes plugged is also located in Table 2.
8.0 Condition Monitoring Tube Inspection Summary Per the Steam Generator Program, as defined in PVGS Procedure 81DP-9RC01, a condition monitoring evaluation was conducted by PVGS Engineering. The results of the eddy current examinations are provided in Section 5.0. An engineering evaluation of the as-found condition of inservice tubes did not reveal any degradation exceeding the threshold values for structural and leakage integrity. As such, all steam generator performance criteria were satisfied for Unit 1 Cycles 22 and 23. No tube pulls or in-situ pressure testing were required based on the results of the examinations.
Foreign Object Search and Retrieval (FOSAR)
FOSAR was performed at the tubesheet elevation in the annulus region and the blowdown lane and at the Flow Distribution Plate elevation in the annulus region. The applicable requirements of Revision 4 of the EPRI Steam Generator Integrity Assessment Guidelines Section 10.3, Foreign Object Search and Retrieval, were applied for the FOSAR inspections.
No metallic foreign objects were identified in SG11 or SG12. Furthermore, no foreign object wear was found in either SG11 or SG12. There were no bobbin PLPs identified by eddy current in SG11 or SG12 that 1) Could not be traced back to prior cycle inspections, 2) Be categorized as a deposit based on special interest (i.e. +Point/X probe) examination, or 3) Confirmed to be deep within the bundle in a low flow area at U1R23.
Blowdown Patch Plate Weld Inspection Summary Also included in the scope of the FOSAR effort was an inspection of the blowdown patch plate welds in SG11 and SG12 that were found to be cracked during 1R15. Inspections confirmed that the weld material in the vicinity of the cracked weld on all 4 patch plates (2 per SG) is intact, and a loose parts concern is not being created. A previous evaluation concluded that, with the presence of the cracked welds, the patch plates in the Unit 2 SGs will continue to perform their design function and that the probability of loose parts being formed is remote. This study also applies to Unit . Thus, the inspection is a conservative measure and there is a very low risk that the cracked welds will affect the structural or leakage integrity of tubes in these steam generators.
Plug Inspections Summary The EPRI PWR Steam Generator Examination Guidelines require that a visual inspection of the previously installed steam generator plugs be performed to assess plug integrity. Additionally, the Examination Guidelines require a verification of the location and presence of existing in-service plugs. The conduct of the plug location and integrity verification was performed in 1R23 per the applicable procedure. A review of the inspection results indicated that all plugs were accounted for and no evidence of potential plug leakage was identified.
Channel Head Inspection Summary A channel head inspection was also performed in response to Westinghouse Engineering Nuclear Safety Advisory Letter (NSAL) 12-1, dated January 5, 2012. The inspection identified no degradation.
TABLE 1 EXAMINATION
SUMMARY
SCOPE DESCRIPTION SG 11 SG 12 Exam Description Extents Scope Scope FULL LENGTH BOBBIN TEC-TEH 12427 7763 HOT LEG BOBBIN VS3-TEH 0
5589 COLD LEG BOBBIN VS3-TEC 0
5595 HOT LEG ARRAY Various 210 191 COLD LEG ARRAY Various 72 112 Cold Leg
+PT TSC 1
0 Notes:
ARRAY probe technology utilized the X-Probe'
TABLE 2 INDICATION
SUMMARY
DAMAGE MECHANIS M
STEAM GENERATOR 11 STEAM GENERATOR 12 Tubes Indications BW VS EC Tubes Indications BW VS EC Wear 1%-19%
20%-29%
30%-39%
>=40%
Plugged 1112 73 16 1
(11) 1244 75 17 1
699 37 12 1
465 28 5
0 80 10 0
0 1297 67 9
0 (10) 1474 73 9
0 689 28 1
0 671 40 8
0 114 5
0 0
Possible Loose Parts (Array Probe)
PLI PLP PLUGGED 0
7 0
0 7
0 0
4 0
Preventative Engineering Discretion Due To Wear (1)
(0)
PLUGGED (12)
(10)
TOTAL PLUGGED / %
( 138 / 1.097% )
( 140 / 1.113% )
NOTES:
- 1. Numbers in (X) are tubes numbers plugged in each category
- 2. The Tubes column above represents Bobbin Coil results for the number of tubes; using the largest wear indication
- 3. The Indications column above represents Bobbin Coil results for the number of wear indications LEGEND:
BW - batwing VS - vertical strap EC - eggcrate
APPENDIX A TUBE SUPPORT DIAGRAM, LEGEND, and ANALYSIS CODES
PVGS Steam Generator REPLACEMENTS VS1 VS3 VS4 VS2 VS5 07H 06H 05H 04H 03H 02H 01H Inlet Outlet 09C 07C 06C 05C 04C 03C 02C FDP 20 36.33 36.33 36.34 35.95 35.95 35.95 16.5 24 28.125 32.25 26 Typical Spacing Center of 08H to 08C Row 1 - 17.415 Row 2 - 19.736 Row 3 - 22.056 Row 4 - 24.377 Row 5 - 26.698 Row 6 - 29.019 28.125 01C 08H 08C 35.95 36.75 09H 36.75 10C 36.75 11C BW2 BW1 11H 10H 25 + 0.25 clad
LEGEND ROW:
Indicates the row number of a given tube.
COL:
Indicates the column number of a given tube.
VOLTS:
Indicates the peak-to-peak voltage of a given indication response.
DEG:
The measured phase angle of a given indication response.
IND:
Indicates the analysis code or PCT for percent PER or PCT:
The percent through the tube wall of a given indication CRLEN:
Indicates the flaw length, used to identify the length of a wear indication CHN:
Indicates the channel used to make the call LOCN:
Gives indication location at INCH1 to INCH2 relative to known landmarks such as supports, vertical straps, and batwings. Typical location codes are as follows:
- 1 Vertical Strap................................VS1
- 1 Batwing.........................................BW1
- 1 Support Plate in Hot Leg...............01H
- 7 Support Plate in Cold Leg.............07C Top Tube Sheet Cold Leg..................TSC Tube End Hot Leg..............................TEH Tube End Cold Leg............................TEC BEGT and ENDT:
Indicates the beginning and of the test; together they document the examination extent PDIA:
Documents the probe diameter PTYPE:
Documents the probe type CAL:
Indicates calibration number L:
Indicates the leg the examination was conducted from IDX:
This comment field is utilized to document comments UTIL1 & 2: Utility columns to support administrative notes
Analysis CODES:
Absolute Drift.................................................................... ADI Bulge.................................................................................. BLG Dented Buff Mark.............................................................. DBM Deposit............................................................................... DEP Dent.................................................................................... DNT Data Quality Acceptance.................................................... DQA Distorted Support Signal With Indication.......................... DSI Distorted Top of Tubesheet With Indication...................... DTI Geometric Indication.......................................................... GEO ID Chatter........................................................................... IDC Indication Not Found......................................................... INF Indication Not Reportable.................................................. INR Large Noise Indication.LNI Multiple Axial Indication................................................... MAI Manufacturer Burnishing Mark.......................................... MBM Mixed Mode Indication...................................................... MMI Multiple Circumferential Indication................................... MCI Multiple Volumetric Indication.......................................... MVI No Detectable Defect......................................................... NDD No Discontinuity Found..................................................... NDF Non-Quantifiable Indication.............................................. NQI No Tube Sheet Expansion.................................................. NTE Obstructed.......................................................................... OBS Over Expanded................................................................... OXP Previous Array Call.PAC Previous Bobbin Call......................................................... PBC Percent.PCT Possible Deposit................................................................. PDP Positive Identification........................................................ PID Positive Identification Verified.......................................... PIV Possible Loose Part with Indication................................... PLI Possible Loose Part............................................................ PLP Previous RC Call................................................................ PRC Proximity.....PRX Possible Support Anomaly................................................. PSA Possible Support Indication................................................ PSI Permeability Variation Noise............................................. PVN Retest Bad Data.................................................................. RBD Retest Identification Check................................................ RIC Retest Large WearRLW Retest with Magnetic Bias RC Probe................................. RMB Single Axial Indication...................................................... SAI Single Circumferential Indication...................................... SCI Single Volumetric Indication............................................. SVI Senior (Lead) Analysis Review.......................................... SR Sludge................................................................................ SLG To Be Plugged.................................................................... TBP Volumetric Indication........................................................ VOL Wear.WAR
APPENDIX B STEAM GENERATOR 11
SUMMARY
DATA SHEETS
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 11 2
2.55 178 DNT P1 08H
-0.87 TEH TEC 0.61 CBAY2 10 C
10 0
11 11 2
NDF P23 08H
-0.87 08H TEH 0.61 NYAX2 67 H
49 0
11 51 8
1.13 84 MBM 6
07H 23.75 TEH TEC 0.61 CBAY2 12 C
41 0
11 55 12 1.59 80 MBM 6
05H 19.05 TEH TEC 0.61 CBAY2 12 C
139 0
11 48 13 0.19 121 PCT 8
P2 09C
-1.62 TEH TEC 0.61 CBAY2 10 C
134 0
11 50 13 0.2 42 PCT 8
P2 VS3
-0.86 TEH TEC 0.61 CBAY2 10 C
133 0
11 33 14 0.1 154 PCT 5
P2 VS3
-1 TEH TEC 0.61 CBAY2 10 C
164 0
11 37 14 0.33 78 PCT 12 P2 VS3 0.78 TEH TEC 0.61 CBAY2 10 C
166 0
11 43 14 0.6 95 MBM 6
04C 6.5 TEH TEC 0.61 CBAY2 10 C
169 0
11 61 14 0.2 21 PCT 8
P2 BW2 0.4 TEH TEC 0.61 CBAY2 10 C
178 0
11 63 14 0.37 42 PCT 13 P2 VS4 1.06 TEH TEC 0.61 CBAY2 10 C
179 0
11 8
15 0.25 133 PCT 8
P2 BW2
-1.58 TEH TEC 0.61 CBAY2 36 C
44 0
11 56 15 0.66 77 MBM 6
07C 24.69 TEH TEC 0.61 CBAY2 12 C
154 0
11 83 16 0.35 60 PCT 13 P2 VS3 0.88 TEH TEC 0.61 CBAY2 48 C
59 0
11 83 16 0.56 95 PCT 18 P2 BW2
-0.94 TEH TEC 0.61 CBAY2 48 C
59 0
11 28 17 0.19 153 PCT 8
P2 VS3
-0.62 TEH TEC 0.61 CBAY2 10 C
202 0
11 67 18 0.24 57 PCT 10 P2 BW2 0.96 TEH TEC 0.61 CBAY2 10 C
239 0
11 79 18 0.39 118 PCT 11 P2 BW1 0.87 TEH TEC 0.61 CBAY2 50 C
58 0
11 98 19 0.37 89 PCT 14 P2 BW2
-0.97 TEH TEC 0.61 CBAY2 48 C
88 0
11 98 19 0.27 157 NQI P1 TSC 0.94 TEH TEC 0.61 CBAY2 48 C
88 0
11 98 19 NDF P31 TSC 0.94 01C TEC 0.61 NYAX2 62 C
16 0
11 55 20 0.35 72 PCT 11 P2 BW1 1.98 TEH TEC 0.61 CBAY2 12 C
259 0
11 67 20 0.3 73 PCT 10 P2 BW1 0.53 TEH TEC 0.61 CBAY2 12 C
265 0
11 73 20 0.28 26 PCT 11 P2 VS4 0.93 TEH TEC 0.61 CBAY2 48 C
41 0
11 79 20 0.23 45 PCT 10 P2 BW1 1
TEH TEC 0.61 CBAY2 48 C
38 0
11 83 20 0.26 91 PCT 11 P2 BW1 0.84 TEH TEC 0.61 CBAY2 48 C
36 0
11 30 21 0.16 133 PCT 7
P2 VS3
-0.15 TEH TEC 0.61 CBAY2 10 C
259 0
11 50 21 4.35 179 DNT P1 08C 11 TEH TEC 0.61 CBAY2 10 C
249 0
11 54 21 2.54 179 DNT P1 08C 25.22 TEH TEC 0.61 CBAY2 10 C
247 0
11 66 21 3.49 92 LNI P7 TSH
-0.12 TEH TEC 0.61 CBAY2 10 C
241 0
11 66 21 NDF P30 TSH
-0.12 01H TEH 0.61 NYAX2 67 H
47 0
11 80 21 0.61 87 PCT 16 P2 VS4 0.99 TEH TEC 0.61 CBAY2 50 C
47 0
11 85 22 0.35 69 PCT 10 P2 BW2 0.89 TEH TEC 0.61 CBAY2 50 C
33 0
11 93 22 0.36 79 PCT 11 P2 BW2 1.03 TEH TEC 0.61 CBAY2 50 C
29 0
11 97 22 0.35 84 PCT 10 P2 BW1 0.71 TEH TEC 0.61 CBAY2 50 C
27 0
11 97 22 0.22 123 PCT 7
P2 BW2 0.76 TEH TEC 0.61 CBAY2 50 C
27 0
11 60 23 0.22 112 PCT 8
P2 VS3
-0.81 TEH TEC 0.61 CBAY2 12 C
272 0
11 70 23 0.4 91 PCT 12 P2 VS2 0.87 TEH TEC 0.61 CBAY2 12 C
267 0
11 86 23 0.23 49 PCT 10 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 48 C
16 0
11 90 23 0.22 40 PCT 9
P2 VS2
-0.97 TEH TEC 0.61 CBAY2 48 C
18 0
11 92 23 0.24 50 PCT 10 P2 BW1
-0.7 TEH TEC 0.61 CBAY2 48 C
19 0
11 94 23 0.26 105 PCT 11 P2 BW1
-0.7 TEH TEC 0.61 CBAY2 48 C
20 0
11 94 23 0.32 98 PCT 12 P2 BW2
-0.84 TEH TEC 0.61 CBAY2 48 C
20 0
11 100 23 0.23 130 PCT 10 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 48 C
23 0
11 104 23 0.25 67 PCT 10 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 48 C
25 0
11 106 23 0.25 77 PCT 10 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 48 C
210 0
11 61 24 0.34 55 PCT 11 P2 VS2
-0.88 TEH TEC 0.61 CBAY2 16 C
24 0
11 61 24 0.32 83 PCT 10 P2 VS3
-0.82 TEH TEC 0.61 CBAY2 16 C
24 0
11 81 24 0.32 80 PCT 12 P2 BW2 0.88 TEH TEC 0.61 CBAY2 44 C
281 0
11 85 24 0.42 60 PCT 14 P2 BW2 0.8 TEH TEC 0.61 CBAY2 44 C
279 0
11 87 24 0.34 57 PCT 12 P2 BW2 0.75 TEH TEC 0.61 CBAY2 44 C
278 0
11 99 24 0.61 84 PCT 18 P2 BW2 0.86 TEH TEC 0.61 CBAY2 44 C
267 0
SG 11 Summary Data Sheets Page 1 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 101 24 0.65 87 PCT 19 P2 BW2 0.93 TEH TEC 0.61 CBAY2 44 C
266 0
11 103 24 0.44 64 PCT 15 P2 BW2 0.88 TEH TEC 0.61 CBAY2 44 C
265 0
11 107 24 0.34 111 PCT 13 P2 BW1 0.89 TEH TEC 0.61 CBAY2 48 C
211 0
11 98 25 0.3 129 PCT 9
P2 VS2 0.85 TEH TEC 0.61 CBAY2 50 C
23 0
11 29 26 4.28 178 DNT P1 BW1 2.05 TEH TEC 0.61 CBAY2 14 C
68 0
11 29 26 NDF P18 BW1 2.05 VS3 TEH 0.61 NYAX2 67 H
46 0
11 49 26 0.26 77 PCT 11 P2 BW1
-1.05 TEH TEC 0.61 CBAY2 14 C
78 0
11 81 26 0.44 87 PCT 13 P2 VS2 0.83 TEH TEC 0.61 CBAY2 46 C
291 0
11 113 26 5.5 177 DNT P1 TSC 1.92 TEH TEC 0.61 CBAY2 48 C
217 0
11 113 26 NDF P32 TSC 1.92 01C TEC 0.61 NYAX2 62 C
15 0
11 48 27 0.33 121 PCT 10 P2 BW1
-0.77 TEH TEC 0.61 CBAY2 16 C
39 0
11 74 27 0.28 86 PCT 11 P2 VS3 0.72 TEH TEC 0.61 CBAY2 44 C
244 0
11 90 27 0.3 87 PCT 11 P2 10H
-1.61 TEH TEC 0.61 CBAY2 44 C
252 0
11 49 28 0.33 101 PCT 11 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 16 C
76 0
11 77 28 0.4 78 PCT 14 P2 BW1 0.91 TEH TEC 0.61 CBAY2 44 C
239 0
11 77 28 0.3 71 PCT 11 P2 VS2 0.79 TEH TEC 0.61 CBAY2 44 C
239 0
11 81 28 0.35 66 PCT 13 P2 BW2 0.96 TEH TEC 0.61 CBAY2 44 C
235 0
11 85 28 0.28 94 PCT 11 P2 VS2 0.89 TEH TEC 0.61 CBAY2 44 C
233 0
11 87 28 0.39 88 PCT 14 P2 VS2 0.74 TEH TEC 0.61 CBAY2 44 C
232 0
11 103 28 0.41 90 PCT 14 P2 VS3
-0.69 TEH TEC 0.61 CBAY2 44 C
224 0
11 107 28 0.25 50 PCT 10 P2 BW2 0.9 TEH TEC 0.61 CBAY2 44 C
222 0
11 46 29 0.24 94 PCT 10 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 14 C
99 0
11 50 29 2.51 179 DNT P1 VS3
-0.72 TEH TEC 0.61 CBAY2 14 C
97 0
11 50 29 NDF P11 VS3
-0.72 VS3 TEH 0.61 NYAX2 67 H
45 0
11 60 29 0.29 119 PCT 12 P2 VS4
-0.92 TEH TEC 0.61 CBAY2 14 C
92 0
11 86 29 0.3 70 PCT 10 P2 VS2 0.88 TEH TEC 0.61 CBAY2 46 C
264 0
11 86 29 0.53 121 PCT 15 P2 VS3 0.83 TEH TEC 0.61 CBAY2 46 C
264 0
11 96 29 0.47 132 PCT 14 P2 BW2
-0.86 TEH TEC 0.61 CBAY2 46 C
269 0
11 102 29 0.47 107 PCT 14 P2 BW2
-1 TEH TEC 0.61 CBAY2 46 C
272 0
11 106 29 0.25 65 PCT 9
P2 VS2 0.88 TEH TEC 0.61 CBAY2 46 C
274 0
11 106 29 0.22 94 PCT 8
P2 VS4 0.9 TEH TEC 0.61 CBAY2 46 C
274 0
11 112 29 0.51 103 PCT 15 P2 BW2 0.95 TEH TEC 0.61 CBAY2 46 C
277 0
11 118 29 0.24 125 PCT 10 P2 VS4
-0.78 TEH TEC 0.61 CBAY2 48 C
220 0
11 118 29 0.34 105 PCT 13 P2 BW2 1.01 TEH TEC 0.61 CBAY2 48 C
220 0
11 31 30 0.21 147 PCT 9
P2 VS3 0.81 TEH TEC 0.61 CBAY2 14 C
127 0
11 45 30 0.21 80 PCT 9
P2 BW1
-0.82 TEH TEC 0.61 CBAY2 14 C
134 0
11 49 30 0.22 87 PCT 10 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 14 C
136 0
11 51 30 0.23 139 PCT 10 P2 BW1 0.91 TEH TEC 0.61 CBAY2 14 C
137 0
11 77 30 0.33 44 PCT 11 P2 VS2 0.81 TEH TEC 0.61 CBAY2 46 C
251 0
11 87 30 0.32 60 PCT 11 P2 BW2
-0.93 TEH TEC 0.61 CBAY2 46 C
246 0
11 89 30 0.36 58 PCT 11 P2 BW2
-0.9 TEH TEC 0.61 CBAY2 46 C
245 0
11 105 30 0.32 64 PCT 10 P2 BW2
-0.65 TEH TEC 0.61 CBAY2 46 C
237 0
11 107 30 0.28 138 PCT 10 P2 BW1
-0.56 TEH TEC 0.61 CBAY2 46 C
236 0
11 109 30 0.32 56 PCT 11 P2 VS3
-0.78 TEH TEC 0.61 CBAY2 46 C
235 0
11 48 31 0.33 133 PCT 11 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 16 C
98 0
11 56 31 0.38 71 PCT 12 P2 BW1
-1.61 TEH TEC 0.61 CBAY2 16 C
94 0
11 68 31 0.29 60 PCT 10 P2 VS4
-0.77 TEH TEC 0.61 CBAY2 16 C
88 0
11 104 31 0.22 83 PCT 9
P2 BW1
-0.87 TEH TEC 0.61 CBAY2 44 C
203 0
11 122 31 0.23 80 PCT 10 P2 VS4
-0.8 TEH TEC 0.61 CBAY2 48 C
235 0
11 49 32 0.34 75 PCT 11 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 16 C
136 0
11 49 32 0.3 146 PCT 10 P2 BW1 0.99 TEH TEC 0.61 CBAY2 16 C
136 0
11 65 32 0.3 86 PCT 10 P2 BW1 1.1 TEH TEC 0.61 CBAY2 16 C
144 0
SG 11 Summary Data Sheets Page 2 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 73 32 0.24 44 PCT 10 P2 BW1 1.01 TEH TEC 0.61 CBAY2 44 C
172 0
11 97 32 0.25 141 PCT 10 P2 BW1
-0.75 TEH TEC 0.61 CBAY2 44 C
184 0
11 12 33 0.32 142 PCT 10 P2 08H 0.69 TEH TEC 0.61 CBAY2 14 C
176 0
11 116 33 0.29 144 PCT 10 P2 BW1 0.85 TEH TEC 0.61 CBAY2 46 C
211 0
11 118 33 0.31 146 PCT 10 P2 BW1 0.85 TEH TEC 0.61 CBAY2 46 C
206 0
11 41 34 0.32 86 PCT 13 P2 VS3
-1.01 TEH TEC 0.61 CBAY2 14 C
192 0
11 45 34 0.26 34 PCT 11 P2 BW2
-0.92 TEH TEC 0.61 CBAY2 14 C
194 0
11 47 34 0.25 48 PCT 10 P2 BW1 1.12 TEH TEC 0.61 CBAY2 14 C
195 0
11 95 34 0.29 69 PCT 10 P2 BW1 0.91 TEH TEC 0.61 CBAY2 46 C
191 0
11 99 34 0.37 40 PCT 12 P2 BW2 0.91 TEH TEC 0.61 CBAY2 46 C
193 0
11 107 34 0.41 60 PCT 13 P2 BW2 1.53 TEH TEC 0.61 CBAY2 46 C
197 0
11 115 34 0.33 87 PCT 11 P2 VS3
-0.75 TEH TEC 0.61 CBAY2 46 C
201 0
11 117 34 0.43 136 PCT 13 P2 VS2
-1.15 TEH TEC 0.61 CBAY2 46 C
202 0
11 119 34 0.36 113 PCT 11 P2 BW2 0.88 TEH TEC 0.61 CBAY2 46 C
203 0
11 84 35 0.26 81 PCT 10 P2 VS2 0.74 TEH TEC 0.61 CBAY2 44 C
164 0
11 84 35 0.25 77 PCT 10 P2 VS3 0.85 TEH TEC 0.61 CBAY2 44 C
164 0
11 90 35 0.85 100 PCT 22 P2 10H
-0.84 TEH TEC 0.61 CBAY2 44 C
161 0
11 90 35 0.34 95 PCT 13 P2 VS2
-0.91 TEH TEC 0.61 CBAY2 44 C
161 0
11 90 35 0.77 289 WAR 16 0.2 P37 10H
-0.84 10H TEH 0.61 NYAX2 67 H
44 F
0 11 29 36 0.87 89 MBM 6
02H 22.28 TEH TEC 0.61 CBAY2 16 C
189 0
11 29 36 0.68 81 MBM 6
02H 26.71 TEH TEC 0.61 CBAY2 16 C
189 0
11 69 36 0.33 126 PCT 10 P2 BW1
-0.73 TEH TEC 0.61 CBAY2 16 C
209 0
11 77 36 0.25 118 PCT 10 P2 VS2 0.98 TEH TEC 0.61 CBAY2 44 C
121 0
11 109 36 0.62 105 PCT 18 P2 VS2
-1.13 TEH TEC 0.61 CBAY2 44 C
137 0
11 109 36 0.56 126 PCT 17 P2 VS3 0.66 TEH TEC 0.61 CBAY2 44 C
137 0
11 117 36 0.41 99 PCT 14 P2 BW1 0.92 TEH TEC 0.61 CBAY2 44 C
141 0
11 48 37 0.21 91 PCT 9
P2 BW2 0.89 TEH TEC 0.61 CBAY2 18 C
7 0
11 86 37 0.38 86 PCT 12 P2 VS4
-0.83 TEH TEC 0.61 CBAY2 46 C
169 0
11 116 37 0.4 56 PCT 12 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 46 C
154 0
11 128 37 0.98 109 PCT 24 P2 VS2 0.89 TEH TEC 0.61 CBAY2 52 C
43 0
11 128 37 0.67 101 PCT 20 P2 VS3 0.8 TEH TEC 0.61 CBAY2 52 C
43 0
11 128 37 2.27 94 WAR 28 0.6 P12 VS2 0.88 VS3 TEH 0.61 NYAX2 67 H
29 T
0 11 128 37 1.68 106 WAR 24 0.38 P12 VS3 0.8 VS3 TEH 0.61 NYAX2 67 H
29 T
0 11 61 38 0.36 44 PCT 13 P2 BW2
-0.95 TEH TEC 0.61 CBAY2 18 C
51 0
11 77 38 0.29 124 PCT 10 P2 VS4
-0.52 TEH TEC 0.61 CBAY2 46 C
125 0
11 101 38 0.25 65 PCT 9
P2 VS2 0.69 TEH TEC 0.61 CBAY2 46 C
137 0
11 111 38 0.34 121 PCT 11 P2 BW1 0.98 TEH TEC 0.61 CBAY2 46 C
142 0
11 113 38 1.75 105 PCT 32 P2 VS2
-1.01 TEH TEC 0.61 CBAY2 46 C
143 0
11 113 38 0.32 117 PCT 10 P2 VS3
-0.94 TEH TEC 0.61 CBAY2 46 C
143 0
11 113 38 2.19 110 WAR 27 0.4 P20 VS2
-0.99 VS3 TEH 0.61 NYAX2 67 H
27 T
0 11 113 38 0.59 116 WAR 15 0.2 P20 VS3
-1.01 VS3 TEH 0.61 NYAX2 67 H
27 F
0 11 113 38 PID P2 VS2
-1.01 TEH TEC 0.61 CBAY2 276 C
7 0
11 115 38 0.39 102 PCT 12 P2 VS2
-1.01 TEH TEC 0.61 CBAY2 46 C
144 0
11 56 39 0.41 97 PCT 12 P2 VS3
-0.97 TEH TEC 0.61 CBAY2 16 C
217 0
11 80 39 0.32 120 PCT 10 P2 VS2
-0.82 TEH TEC 0.61 CBAY2 46 C
115 0
11 84 39 0.29 60 PCT 10 P2 BW2
-0.94 TEH TEC 0.61 CBAY2 46 C
113 0
11 86 39 0.37 56 PCT 12 P2 BW2
-0.99 TEH TEC 0.61 CBAY2 46 C
112 0
11 90 39 0.32 42 PCT 10 P2 10H
-1.11 TEH TEC 0.61 CBAY2 46 C
110 0
11 98 39 0.23 139 PCT 10 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 48 C
236 0
11 118 39 0.43 54 PCT 15 P2 BW2
-0.96 TEH TEC 0.61 CBAY2 48 C
246 0
11 120 39 0.23 59 PCT 10 P2 VS4
-0.8 TEH TEC 0.61 CBAY2 48 C
247 0
11 132 39 0.25 104 NQI 3
11H
-0.03 TEH TEC 0.61 CBAY2 52 C
23 0
SG 11 Summary Data Sheets Page 3 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 132 39 0.4 262 WAR 13 0.12 P10 11H 0.9 11H TEH 0.61 NYAX2 67 H
34 F
0 11 3
40 INF 2
TSC 0
TEH TEC 0.61 CBAY2 34 C
58 HR 0
11 3
40 NDF P15 TSC 0
01C TEC 0.61 NYAX2 58 C
12 0
11 49 40 0.21 139 PCT 7
P2 BW1
-0.95 TEH TEC 0.61 CBAY2 20 C
46 0
11 81 40 0.36 124 PCT 12 P2 VS2 0.65 TEH TEC 0.61 CBAY2 46 C
97 0
11 91 40 0.45 47 PCT 14 P2 BW2 0.86 TEH TEC 0.61 CBAY2 46 C
102 0
11 103 40 0.32 75 PCT 12 P2 BW1 0.52 TEH TEC 0.61 CBAY2 48 C
264 0
11 115 40 0.38 116 PCT 14 P2 VS3
-1.03 TEH TEC 0.61 CBAY2 48 C
258 0
11 68 41 0.24 34 PCT 10 P2 VS2 0.8 TEH TEC 0.61 CBAY2 18 C
55 0
11 76 41 0.24 85 PCT 10 P2 VS3
-0.8 TEH TEC 0.61 CBAY2 44 C
113 0
11 90 41 0.42 84 PCT 14 P2 10H
-1.02 TEH TEC 0.61 CBAY2 44 C
106 0
11 33 42 0.28 38 PCT 11 P2 BW2
-0.96 TEH TEC 0.61 CBAY2 18 C
94 0
11 59 42 0.27 71 PCT 11 P2 BW1 0.95 TEH TEC 0.61 CBAY2 18 C
106 0
11 61 42 0.27 51 PCT 10 P2 BW2 1.06 TEH TEC 0.61 CBAY2 18 C
107 0
11 63 42 0.45 31 PCT 15 P2 BW2 0.97 TEH TEC 0.61 CBAY2 18 C
108 0
11 65 42 0.27 97 PCT 10 P2 BW1 0.19 TEH TEC 0.61 CBAY2 18 C
109 0
11 75 42 0.28 39 PCT 11 P2 BW1 0.88 TEH TEC 0.61 CBAY2 44 C
93 0
11 125 42 0.37 98 PCT 11 P2 BW2 0.94 TEH TEC 0.61 CBAY2 50 C
160 0
11 127 42 0.24 123 PCT 10 P2 BW2 0.92 TEH TEC 0.61 CBAY2 52 C
62 0
11 4
43 0.35 78 PCT 11 P2 BW2
-0.68 TEH TEC 0.61 CBAY2 34 C
81 0
11 92 43 0.33 83 PCT 11 P2 VS3 0.77 TEH TEC 0.61 CBAY2 46 C
81 0
11 100 43 0.42 146 PCT 12 P2 10H
-0.79 TEH TEC 0.61 CBAY2 46 C
77 0
11 130 43 0.52 109 PCT 17 P2 VS2 1.1 TEH TEC 0.61 CBAY2 52 C
68 0
11 47 44 0.32 60 PCT 10 P2 BW1 1.01 TEH TEC 0.61 CBAY2 20 C
105 0
11 49 44 0.31 44 PCT 10 P2 BW1 0.73 TEH TEC 0.61 CBAY2 20 C
106 0
11 65 44 0.22 104 PCT 8
P2 BW1
-0.87 TEH TEC 0.61 CBAY2 20 C
114 0
11 89 44 0.3 78 PCT 10 P2 BW1 1.11 TEH TEC 0.61 CBAY2 46 C
66 0
11 113 44 NDF P30 FDP
-0.36 01C TEC 0.61 NYAX2 62 C
14 0
11 125 44 0.91 108 PCT 23 P2 VS2
-1 TEH TEC 0.61 CBAY2 52 C
17 0
11 125 44 2.6 117 WAR 29 0.4 P20 VS2
-1.1 VS3 TEH 0.61 NYAX2 67 H
26 T
0 11 127 44 0.22 123 PCT 9
P2 VS1
-0.75 TEH TEC 0.61 CBAY2 52 C
18 0
11 137 44 0.23 101 PCT 9
P2 VS1 0.64 TEH TEC 0.61 CBAY2 52 C
28 0
11 137 44 0.25 81 PCT 10 P2 VS3 0.89 TEH TEC 0.61 CBAY2 52 C
28 0
11 48 45 0.36 111 PCT 13 P2 BW1 0.91 TEH TEC 0.61 CBAY2 18 C
121 0
11 56 45 0.21 151 PCT 9
P2 BW1
-1.4 TEH TEC 0.61 CBAY2 18 C
117 0
11 124 45 0.33 100 PCT 10 P2 VS3 0.89 TEH TEC 0.61 CBAY2 54 C
70 0
11 126 45 0.35 126 PCT 11 P2 VS2 1.21 TEH TEC 0.61 CBAY2 54 C
71 0
11 45 46 0.24 89 PCT 10 P2 BW1
-0.92 TEH TEC 0.61 CBAY2 18 C
157 0
11 49 46 0.55 87 MBM 6
07C 9.74 TEH TEC 0.61 CBAY2 18 C
159 0
11 77 46 0.34 96 PCT 12 P2 VS4
-0.65 TEH TEC 0.61 CBAY2 44 C
59 0
11 119 46 0.75 105 PCT 19 P2 VS2
-0.98 TEH TEC 0.61 CBAY2 54 C
16 0
11 119 46 1.99 297 WAR 26 0.26 P20 VS2
-0.86 VS3 TEH 0.61 NYAX2 67 H
25 T
0 11 121 46 0.8 112 PCT 20 P2 VS2
-0.93 TEH TEC 0.61 CBAY2 54 C
17 0
11 121 46 2.12 117 WAR 27 0.21 P20 VS2
-1.03 VS3 TEH 0.61 NYAX2 67 H
24 F
0 11 127 46 0.35 70 PCT 11 P2 VS1
-0.74 TEH TEC 0.61 CBAY2 54 C
78 0
11 56 47 0.3 109 PCT 10 P2 BW1
-1.83 TEH TEC 0.61 CBAY2 20 C
124 0
11 126 47 0.28 67 PCT 11 P2 VS1 0.82 TEH TEC 0.61 CBAY2 52 C
78 0
11 134 47 0.22 112 PCT 9
P2 VS1
-0.71 TEH TEC 0.61 CBAY2 52 C
82 0
11 134 47 0.22 130 PCT 9
P2 BW2
-0.95 TEH TEC 0.61 CBAY2 52 C
82 0
11 136 47 0.34 137 PCT 11 P2 BW2
-0.83 TEH TEC 0.61 CBAY2 54 C
29 0
11 138 47 0.47 56 PCT 14 P2 BW2
-0.97 TEH TEC 0.61 CBAY2 54 C
36 0
11 144 47 0.24 158 PCT 10 P2 VS3
-0.87 TEH TEC 0.61 CBAY2 52 C
44 0
SG 11 Summary Data Sheets Page 4 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 144 47 NDF P30 TSH 0.98 01H TEH 0.61 NYAX2 67 H
35 0
11 57 48 0.77 87 MBM 6
08C 10.89 TEH TEC 0.61 CBAY2 20 C
170 0
11 61 48 0.33 55 PCT 10 P2 BW1 0.85 TEH TEC 0.61 CBAY2 20 C
172 0
11 65 48 0.44 101 PCT 13 P2 BW1 0.48 TEH TEC 0.61 CBAY2 20 C
174 0
11 67 48 0.39 68 PCT 12 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 20 C
175 0
11 79 48 0.31 95 PCT 10 P2 VS4
-0.65 TEH TEC 0.61 CBAY2 46 C
19 0
11 97 48 0.34 105 PCT 11 P2 VS4 1.06 TEH TEC 0.61 CBAY2 46 C
28 0
11 115 48 0.26 128 PCT 10 P2 BW1 0.49 TEH TEC 0.61 CBAY2 52 C
93 0
11 129 48 0.33 82 PCT 12 P2 BW2 0.83 TEH TEC 0.61 CBAY2 52 C
86 0
11 131 48 0.6 113 PCT 18 P2 BW2 0.96 TEH TEC 0.61 CBAY2 52 C
85 0
11 133 48 0.25 123 PCT 10 P2 BW2 0.83 TEH TEC 0.61 CBAY2 52 C
84 0
11 135 48 0.37 120 PCT 13 P2 BW2 0.9 TEH TEC 0.61 CBAY2 52 C
83 0
11 141 48 2.58 178 DNT P1 11H
-1.14 TEH TEC 0.61 CBAY2 52 C
32 0
11 141 48 NDF P16 11H
-1.14 11H TEH 0.61 NYAX2 67 H
36 0
11 60 49 0.29 121 PCT 11 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 18 C
173 0
11 70 49 0.24 126 PCT 10 P2 BW1
-0.08 TEH TEC 0.61 CBAY2 44 C
54 0
11 90 49 0.22 25 PCT 9
P2 10H
-1.43 TEH TEC 0.61 CBAY2 44 C
44 0
11 120 49 0.33 136 PCT 10 P2 BW1 0.87 TEH TEC 0.61 CBAY2 54 C
84 0
11 132 49 0.36 112 PCT 13 P2 VS1
-0.68 TEH TEC 0.61 CBAY2 56 C
133 0
11 136 49 0.31 76 PCT 10 P2 VS1
-0.69 TEH TEC 0.61 CBAY2 54 C
92 0
11 39 50 0.3 86 PCT 11 P2 VS3
-0.96 TEH TEC 0.61 CBAY2 18 C
212 0
11 65 50 0.31 49 PCT 12 P2 BW1 0.76 TEH TEC 0.61 CBAY2 18 C
225 0
11 89 50 0.32 60 PCT 12 P2 VS2
-0.9 TEH TEC 0.61 CBAY2 44 C
23 0
11 109 50 0.34 147 PCT 12 P2 BW1
-1.71 TEH TEC 0.61 CBAY2 44 C
33 0
11 115 50 0.35 104 PCT 13 P2 BW1 0.82 TEH TEC 0.61 CBAY2 56 C
132 0
11 129 50 0.42 87 PCT 14 P2 VS2
-0.89 TEH TEC 0.61 CBAY2 56 C
129 0
11 143 50 3.34 179 DNT P1 11H
-1.26 TEH TEC 0.61 CBAY2 54 C
47 0
11 143 50 NDF P13 11H
-1.26 11H TEH 0.61 NYAX2 67 H
37 0
11 112 51 0.21 42 PCT 7
P2 BW1
-0.8 TEH TEC 0.61 CBAY2 42 C
227 0
11 126 51 0.46 122 PCT 15 P2 VS3 0.96 TEH TEC 0.61 CBAY2 52 C
98 0
11 126 51 0.47 106 PCT 16 P2 VS3 1.27 TEH TEC 0.61 CBAY2 52 C
98 0
11 126 51 0.54 111 PCT 17 P2 VS4
-1.18 TEH TEC 0.61 CBAY2 52 C
98 0
11 128 51 0.31 129 PCT 12 P2 VS1 0.9 TEH TEC 0.61 CBAY2 52 C
99 0
11 130 51 1.2 112 PCT 27 P2 VS3 1.05 TEH TEC 0.61 CBAY2 52 C
100 0
11 130 51 2.01 275 WAR 27 0.36 P12 VS3 1.05 VS3 TEH 0.61 NYAX2 67 H
23 T
0 11 132 51 0.31 37 PCT 10 P2 11H 0
TEH TEC 0.61 CBAY2 52 C
101 0
11 144 51 0.37 89 PCT 11 P2 VS5
-1.13 TEH TEC 0.61 CBAY2 54 C
48 0
11 146 51 0.31 98 PCT 12 P2 11H
-0.08 TEH TEC 0.61 CBAY2 52 C
58 0
11 47 52 0.26 77 PCT 9
P2 BW1 0.92 TEH TEC 0.61 CBAY2 20 C
225 0
11 61 52 0.28 65 PCT 9
P2 BW1 0.99 TEH TEC 0.61 CBAY2 20 C
232 0
11 63 52 0.31 66 PCT 10 P2 BW1 1.07 TEH TEC 0.61 CBAY2 20 C
233 0
11 65 52 0.31 66 PCT 10 P2 BW1 0.91 TEH TEC 0.61 CBAY2 20 C
234 0
11 123 52 0.33 106 PCT 12 P2 VS1
-0.83 TEH TEC 0.61 CBAY2 52 C
115 0
11 125 52 0.3 95 PCT 11 P2 BW2 0.9 TEH TEC 0.61 CBAY2 52 C
114 0
11 127 52 0.35 94 PCT 13 P2 VS2 0.44 TEH TEC 0.61 CBAY2 52 C
113 0
11 127 52 0.23 90 PCT 9
P2 BW2 0.9 TEH TEC 0.61 CBAY2 52 C
113 0
11 131 52 0.43 92 PCT 15 P2 VS1
-0.88 TEH TEC 0.61 CBAY2 52 C
111 0
11 135 52 0.48 117 PCT 16 P2 VS1
-0.86 TEH TEC 0.61 CBAY2 52 C
109 0
11 143 52 0.3 44 PCT 10 P2 VS3
-0.79 TEH TEC 0.61 CBAY2 54 C
62 0
11 98 53 0.3 114 PCT 11 P2 BW1 0.85 TEH TEC 0.61 CBAY2 40 C
222 0
11 102 53 0.48 122 PCT 15 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 40 C
220 0
11 122 53 0.14 84 PCT 5
P2 VS1 0.54 TEH TEC 0.61 CBAY2 54 C
111 0
SG 11 Summary Data Sheets Page 5 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 122 53 0.38 80 PCT 12 P2 VS2 1.13 TEH TEC 0.61 CBAY2 54 C
111 0
11 126 53 0.61 107 PCT 18 P2 VS3 1.08 TEH TEC 0.61 CBAY2 56 C
116 0
11 144 53 0.39 72 PCT 12 P2 VS1
-0.86 TEH TEC 0.61 CBAY2 54 C
61 0
11 65 54 0.31 116 PCT 12 P2 BW1 1.09 TEH TEC 0.61 CBAY2 18 C
283 0
11 75 54 0.24 55 PCT 9
P2 VS2
-0.63 TEH TEC 0.61 CBAY2 40 C
193 0
11 107 54 0.19 110 PCT 8
P2 BW1
-1.29 TEH TEC 0.61 CBAY2 40 C
209 0
11 109 54 0.3 153 PCT 11 P2 BW1
-0.71 TEH TEC 0.61 CBAY2 40 C
210 0
11 111 54 0.39 62 PCT 13 P2 VS3
-1.04 TEH TEC 0.61 CBAY2 40 C
211 0
11 113 54 0.51 127 PCT 16 P2 BW1
-1.14 TEH TEC 0.61 CBAY2 40 C
212 0
11 113 54 0.28 29 PCT 11 P2 VS1
-0.73 TEH TEC 0.61 CBAY2 40 C
212 0
11 113 54 0.39 152 PCT 14 P2 VS1 0.59 TEH TEC 0.61 CBAY2 40 C
212 0
11 113 54 1.4 110 PCT 29 P2 VS4 1.05 TEH TEC 0.61 CBAY2 40 C
212 0
11 113 54 1.93 98 WAR 26 0.17 P16 VS4 1.05 VS3 TEC 0.61 NYAX2 62 C
13 F
0 11 115 54 0.41 87 PCT 14 P2 BW1 0.46 TEH TEC 0.61 CBAY2 40 C
213 0
11 115 54 0.4 99 PCT 14 P2 VS1 0.87 TEH TEC 0.61 CBAY2 40 C
213 0
11 121 54 0.29 112 PCT 11 P2 VS4 1.07 TEH TEC 0.61 CBAY2 56 C
112 0
11 127 54 0.53 122 PCT 17 P2 VS2 0.46 TEH TEC 0.61 CBAY2 56 C
109 0
11 127 54 0.3 50 PCT 11 P2 VS3
-0.73 TEH TEC 0.61 CBAY2 56 C
109 0
11 127 54 0.24 46 PCT 10 P2 VS4 0.95 TEH TEC 0.61 CBAY2 56 C
109 0
11 129 54 0.55 100 PCT 17 P2 VS1
-0.81 TEH TEC 0.61 CBAY2 56 C
108 0
11 141 54 0.25 54 PCT 10 P2 VS2
-0.84 TEH TEC 0.61 CBAY2 56 C
103 0
11 141 54 0.3 60 PCT 11 P2 VS4 0.76 TEH TEC 0.61 CBAY2 56 C
103 0
11 143 54 0.26 51 PCT 10 P2 VS2
-0.89 TEH TEC 0.61 CBAY2 56 C
102 0
11 143 54 0.52 94 PCT 17 P2 VS3
-0.85 TEH TEC 0.61 CBAY2 56 C
102 0
11 143 54 0.31 86 PCT 12 P2 VS4 0.87 TEH TEC 0.61 CBAY2 56 C
102 0
11 147 54 1.9 178 DNT P1 11H
-1.21 TEH TEC 0.61 CBAY2 54 C
51 0
11 147 54 NDF P5 11H
-1.27 11H TEH 0.61 NYAX2 67 H
38 0
11 116 55 0.43 61 PCT 12 P2 BW1 0.96 TEH TEC 0.61 CBAY2 42 C
178 0
11 120 55 0.67 102 PCT 17 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 42 C
176 0
11 152 55 18.41 178 DNT P1 TSC 0.52 TEH TEC 0.61 CBAY2 52 C
52 0
11 152 55 NDF P27 TSC 0.52 01C TEC 0.61 NYAX2 62 C
18 0
11 111 56 0.36 110 PCT 11 P2 BW1 0.9 TEH TEC 0.61 CBAY2 42 C
171 0
11 119 56 0.34 63 PCT 11 P2 BW1 0.87 TEH TEC 0.61 CBAY2 8
C 153 0
11 121 56 0.25 99 PCT 8
P2 VS3 0.97 TEH TEC 0.61 CBAY2 42 C
174 0
11 131 56 0.36 77 PCT 11 P2 BW2 0.82 TEH TEC 0.61 CBAY2 8
C 155 0
11 133 56 0.32 118 PCT 10 P2 11C
-1.57 TEH TEC 0.61 CBAY2 8
C 143 0
11 135 56 3.02 178 DNT P1 VS1 1.11 TEH TEC 0.61 CBAY2 52 C
134 0
11 135 56 NDF P4 VS1 1.11 VS3 TEH 0.61 NYAX2 67 H
22 0
11 141 56 0.22 110 PCT 9
P2 VS2 0.97 TEH TEC 0.61 CBAY2 52 C
131 0
11 141 56 0.35 112 PCT 13 P2 VS3
-0.62 TEH TEC 0.61 CBAY2 52 C
131 0
11 145 56 2.22 177 DNT P1 11H
-1.16 TEH TEC 0.61 CBAY2 52 C
129 0
11 145 56 NDF P14 11H
-1.16 11H TEH 0.61 NYAX2 67 H
41 0
11 149 56 4.46 180 DNT P1 11H
-1.26 TEH TEC 0.61 CBAY2 54 C
53 0
11 149 56 NDF P29 11H
-1.26 11H TEH 0.61 NYAX2 67 H
39 0
11 90 57 0.77 84 PCT 21 P2 10H
-1.71 TEH TEC 0.61 CBAY2 40 C
179 0
11 90 57 0.88 79 WAR 18 0.26 P12 10H
-1.15 10H TEH 0.61 NYAX2 67 H
43 F
0 11 144 57 0.37 92 PCT 13 P2 VS1
-0.86 TEH TEC 0.61 CBAY2 52 C
151 0
11 148 57 0.36 107 PCT 11 P2 BW2
-0.95 TEH TEC 0.61 CBAY2 54 C
57 0
11 65 58 0.68 96 PCT 18 P2 VS3
-0.83 TEH TEC 0.61 CBAY2 24 C
6 0
11 93 58 0.26 101 PCT 10 P2 VS4
-0.82 TEH TEC 0.61 CBAY2 40 C
155 0
11 109 58 0.22 113 PCT 9
P2 VS2
-0.74 TEH TEC 0.61 CBAY2 40 C
163 0
11 121 58 0.24 83 PCT 10 P2 VS2
-0.9 TEH TEC 0.61 CBAY2 6
C 154 0
SG 11 Summary Data Sheets Page 6 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 123 58 0.35 114 PCT 13 P2 BW1 1
TEH TEC 0.61 CBAY2 52 C
135 0
11 137 58 0.76 120 PCT 21 P2 VS2 0.86 TEH TEC 0.61 CBAY2 52 C
139 0
11 137 58 1.95 115 WAR 26 0.22 P20 VS2 0.95 VS3 TEH 0.61 NYAX2 67 H
21 F
0 11 147 58 0.3 84 PCT 11 P2 VS2
-0.81 TEH TEC 0.61 CBAY2 52 C
144 0
11 48 59 0.39 81 PCT 12 P2 09C
-1.77 TEH TEC 0.61 CBAY2 20 C
308 0
11 62 59 0.33 47 PCT 10 P2 BW1
-0.87 TEH TEC 0.61 CBAY2 20 C
301 0
11 68 59 0.3 47 PCT 10 P2 BW1
-0.83 TEH TEC 0.61 CBAY2 20 C
298 0
11 100 59 0.37 75 PCT 11 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 42 C
136 0
11 132 59 0.14 38 PCT 6
P2 11H
-1.77 TEH TEC 0.61 CBAY2 6
C 145 0
11 136 59 0.35 98 PCT 13 P2 VS1
-0.76 TEH TEC 0.61 CBAY2 6
C 142 0
11 140 59 0.29 94 PCT 11 P2 VS1
-0.88 TEH TEC 0.61 CBAY2 52 C
156 0
11 142 59 0.23 68 PCT 9
P2 BW1
-0.73 TEH TEC 0.61 CBAY2 52 C
157 0
11 107 60 0.31 124 PCT 9
P2 BW1
-1.36 TEH TEC 0.61 CBAY2 42 C
128 0
11 125 60 0.37 101 PCT 11 P2 VS1
-0.81 TEH TEC 0.61 CBAY2 8
C 137 0
11 125 60 0.31 78 PCT 10 P2 VS1 0.74 TEH TEC 0.61 CBAY2 8
C 137 0
11 129 60 1.63 103 PCT 31 P2 VS3
-0.8 TEH TEC 0.61 CBAY2 8
C 139 0
11 129 60 2.51 101 WAR 29 0.43 P12 VS3
-0.8 VS3 TEH 0.61 NYAX2 67 H
20 F
0 11 129 60 PID P2 VS3
-0.8 TEH TEC 0.61 CBAY2 276 C
6 0
11 137 60 0.89 108 PCT 23 P2 VS1
-0.79 TEH TEC 0.61 CBAY2 52 C
168 0
11 137 60 2.43 119 WAR 28 0.24 P20 VS1
-0.79 VS3 TEH 0.61 NYAX2 67 H
19 F
0 11 139 60 0.35 88 PCT 13 P2 VS1
-0.86 TEH TEC 0.61 CBAY2 52 C
167 0
11 151 60 0.23 61 PCT 10 P2 BW2 0.95 TEH TEC 0.61 CBAY2 52 C
161 0
11 36 61 0.3 150 PCT 10 P2 VS3
-0.74 TEH TEC 0.61 CBAY2 24 C
26 0
11 108 61 0.48 112 PCT 14 P2 BW1
-1.65 TEH TEC 0.61 CBAY2 8
C 127 0
11 120 61 0.31 53 PCT 10 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 8
C 121 0
11 132 61 0.18 99 PCT 6
P2 11H
-1.22 TEH TEC 0.61 CBAY2 8
C 115 0
11 140 61 0.25 75 PCT 10 P2 VS1
-0.73 TEH TEC 0.61 CBAY2 52 C
172 0
11 152 61 0.27 143 PCT 11 P2 BW2
-0.85 TEH TEC 0.61 CBAY2 52 C
178 0
11 154 61 0.27 36 PCT 10 P2 BW2
-0.89 TEH TEC 0.61 CBAY2 56 C
99 0
11 101 62 0.31 62 PCT 11 P2 BW1 0.98 TEH TEC 0.61 CBAY2 40 C
121 0
11 115 62 0.25 118 PCT 10 P2 VS1
-0.82 TEH TEC 0.61 CBAY2 6
C 131 0
11 125 62 0.46 99 PCT 15 P2 VS1 0.81 TEH TEC 0.61 CBAY2 6
C 136 0
11 133 62 0.96 135 PCT 20 P2 11C
-0.34 TEH TEC 0.61 CBAY2 6
C 140 0
11 133 62 0.86 110 WAR 18 0.2 P1 11C
-1.55 11C TEC 0.61 NYAX2 62 C
17 T
0 11 135 62 0.28 41 PCT 10 P2 11C 0.71 TEH TEC 0.61 CBAY2 6
C 141 0
11 139 62 0.42 87 PCT 15 P2 VS1
-0.9 TEH TEC 0.61 CBAY2 52 C
186 0
11 98 63 0.3 65 PCT 9
P2 BW1
-0.74 TEH TEC 0.61 CBAY2 42 C
94 0
11 132 63 0.22 90 PCT 9
P2 11H
-1.68 TEH TEC 0.61 CBAY2 6
C 116 0
11 134 63 0.26 73 PCT 10 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 6
C 115 0
11 140 63 0.59 103 PCT 18 P2 VS1
-0.86 TEH TEC 0.61 CBAY2 52 C
189 11 0
11 144 63 0.25 82 PCT 10 P2 VS4
-0.76 TEH TEC 0.61 CBAY2 52 C
191 0
11 158 63 0.22 57 PCT 9
P2 VS3 0.93 TEH TEC 0.61 CBAY2 56 C
93 0
11 37 64 0.23 89 PCT 9
P2 BW1
-0.69 TEH TEC 0.61 CBAY2 22 C
49 0
11 41 64 0.79 81 MBM 6
04C 14.7 TEH TEC 0.61 CBAY2 22 C
51 0
11 43 64 12.24 140 PLP 87 TSH 0.23 08H TEH 0.61 NYAX2 65 H
46 SR 0
11 95 64 0.33 113 PCT 10 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 42 C
86 0
11 97 64 0.24 144 PCT 8
P2 BW1 1.04 TEH TEC 0.61 CBAY2 42 C
87 0
11 99 64 0.34 112 PCT 10 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 42 C
88 0
11 111 64 0.32 137 PCT 10 P2 BW1
-2 TEH TEC 0.61 CBAY2 8
C 103 0
11 113 64 0.21 155 PCT 7
P2 BW1 0.79 TEH TEC 0.61 CBAY2 8
C 104 0
11 131 64 0.26 76 PCT 8
P2 BW2 0.82 TEH TEC 0.61 CBAY2 8
C 112 0
11 143 64 0.23 113 PCT 9
P2 VS1 0.62 TEH TEC 0.61 CBAY2 52 C
201 0
SG 11 Summary Data Sheets Page 7 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 153 64 0.26 125 PCT 10 P2 VS2
-1.16 TEH TEC 0.61 CBAY2 52 C
196 0
11 26 65 1.01 107 MBM 6
08H 6.63 TEH TEC 0.61 CBAY2 24 C
91 0
11 30 65 0.31 60 PCT 10 P2 VS3
-0.73 TEH TEC 0.61 CBAY2 24 C
89 0
11 42 65 6.43 137 PLP 167 TSH 0.43 08H TEH 0.61 NYAX2 65 H
43 SR 0
11 44 65 5.52 108 PLP 183 TSH 0.2 08H TEH 0.61 NYAX2 65 H
42 SR 0
11 60 65 0.37 124 PCT 12 P2 BW1
-0.83 TEH TEC 0.61 CBAY2 24 C
74 0
11 62 65 0.28 107 PCT 9
P2 BW1
-0.85 TEH TEC 0.61 CBAY2 24 C
73 0
11 90 65 0.23 70 PCT 9
P2 BW1
-0.71 TEH TEC 0.61 CBAY2 40 C
95 0
11 114 65 0.35 116 PCT 11 P2 BW1 0.56 TEH TEC 0.61 CBAY2 8
C 92 0
11 118 65 0.34 62 PCT 10 P2 BW1
-0.75 TEH TEC 0.61 CBAY2 8
C 90 0
11 122 65 0.34 90 PCT 10 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 8
C 88 0
11 15 66 NDF P24 TSH 0
01H TEH 0.61 NYAX2 65 H
49 0
11 43 66 2.32 260 PLP 7
03H 1.98 TEH TEC 0.61 CBAY2 50 C
135 HR 0
11 43 66 NDF P27 03H 1.89 08H TEH 0.61 NYAX2 65 H
38 0
11 103 66 0.45 83 PCT 15 P2 BW1 0.9 TEH TEC 0.61 CBAY2 40 C
89 0
11 111 66 0.27 136 PCT 10 P2 VS3 0.74 TEH TEC 0.61 CBAY2 6
C 101 0
11 125 66 0.32 37 PCT 12 P2 BW1 0.89 TEH TEC 0.61 CBAY2 6
C 108 0
11 127 66 0.46 117 PCT 15 P2 BW1
-0.73 TEH TEC 0.61 CBAY2 6
C 109 0
11 120 67 0.46 109 PCT 15 P2 BW1
-1.2 TEH TEC 0.61 CBAY2 6
C 89 0
11 126 67 0.26 82 PCT 10 P2 VS1
-0.64 TEH TEC 0.61 CBAY2 6
C 86 0
11 132 67 0.4 67 PCT 13 P2 11H
-1.6 TEH TEC 0.61 CBAY2 6
C 83 0
11 134 67 0.31 81 PCT 12 P2 BW1
-1.1 TEH TEC 0.61 CBAY2 6
C 82 0
11 146 67 0.28 98 PCT 11 P2 VS1
-0.77 TEH TEC 0.61 CBAY2 52 C
228 0
11 156 67 0.27 49 PCT 11 P2 BW2 0.93 TEH TEC 0.61 CBAY2 56 C
82 0
11 25 68 0.07 86 NQI P1 VS3 2.47 TEH TEC 0.61 CBAY2 22 C
101 0
11 25 68 NDF P13 VS3 2.47 VS3 TEH 0.61 NYAX2 65 H
48 0
11 31 68 0.58 97 MBM 6
05C 2.66 TEH TEC 0.61 CBAY2 22 C
104 0
11 71 68 0.38 43 PCT 11 P2 BW1 0.89 TEH TEC 0.61 CBAY2 42 C
40 0
11 95 68 0.34 66 PCT 10 P2 VS4 1
TEH TEC 0.61 CBAY2 42 C
52 0
11 115 68 0.51 100 PCT 14 P2 VS4 1.05 TEH TEC 0.61 CBAY2 8
C 74 0
11 127 68 0.3 124 PCT 9
P2 BW1
-0.75 TEH TEC 0.61 CBAY2 8
C 78 0
11 129 68 0.28 54 PCT 9
P2 VS1
-0.64 TEH TEC 0.61 CBAY2 8
C 79 0
11 129 68 0.4 79 PCT 12 P2 VS4
-0.75 TEH TEC 0.61 CBAY2 8
C 79 0
11 24 69 1.14 50 MBM 6
05H 2.08 TEH TEC 0.61 CBAY2 48 C
188 0
11 32 69 0.98 72 MBM 6
06C 28.95 TEH TEC 0.61 CBAY2 48 C
192 0
11 48 69 0.31 122 PCT 12 P2 BW1 0.85 TEH TEC 0.61 CBAY2 48 C
200 0
11 58 69 0.27 109 PCT 11 P2 VS3 1.07 TEH TEC 0.61 CBAY2 48 C
205 0
11 60 69 0.25 80 PCT 10 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 48 C
206 0
11 90 69 0.29 105 PCT 11 P2 10H
-1.31 TEH TEC 0.61 CBAY2 40 C
61 0
11 104 69 0.47 125 PCT 14 P2 VS3 1.05 TEH TEC 0.61 CBAY2 8
C 65 0
11 128 69 0.45 134 PCT 13 P2 VS1
-0.69 TEH TEC 0.61 CBAY2 8
C 37 0
11 130 69 0.54 93 PCT 15 P2 VS1
-0.61 TEH TEC 0.61 CBAY2 8
C 36 0
11 130 69 0.35 108 PCT 11 P2 VS3 1.04 TEH TEC 0.61 CBAY2 8
C 36 0
11 132 69 0.36 111 PCT 11 P2 VS1
-0.79 TEH TEC 0.61 CBAY2 8
C 35 0
11 158 69 0.46 87 PCT 15 P2 VS2
-0.88 TEH TEC 0.61 CBAY2 56 C
73 0
11 160 69 0.3 84 PCT 11 P2 BW2
-0.88 TEH TEC 0.61 CBAY2 56 C
72 0
11 11 70 0.31 87 PCT 12 P2 BW2 0.83 TEH TEC 0.61 CBAY2 48 C
181 0
11 47 70 0.33 90 PCT 13 P2 BW1 0
TEH TEC 0.61 CBAY2 48 C
163 0
11 97 70 0.35 116 PCT 13 P2 BW1
-0.76 TEH TEC 0.61 CBAY2 40 C
53 0
11 119 70 0.49 92 PCT 16 P2 VS2
-0.95 TEH TEC 0.61 CBAY2 6
C 75 0
11 129 70 0.25 101 PCT 10 P2 VS1 0.74 TEH TEC 0.61 CBAY2 6
C 78 0
11 129 70 0.27 74 PCT 10 P2 VS2
-0.96 TEH TEC 0.61 CBAY2 6
C 78 0
SG 11 Summary Data Sheets Page 8 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 131 70 0.26 79 PCT 10 P2 VS1
-0.73 TEH TEC 0.61 CBAY2 6
C 79 0
11 153 70 5.75 179 DNT P1 VS2 1.09 TEH TEC 0.61 CBAY2 52 C
251 0
11 153 70 NDF P9 VS2 1.09 VS3 TEH 0.61 NYAX2 67 H
18 0
11 161 70 0.29 70 PCT 11 P2 VS2
-0.95 TEH TEC 0.61 CBAY2 56 C
70 0
11 161 70 0.3 62 PCT 11 P2 VS4 0.84 TEH TEC 0.61 CBAY2 56 C
70 0
11 62 71 0.22 91 PCT 8
P2 BW1
-0.88 TEH TEC 0.61 CBAY2 22 C
126 0
11 92 71 0.2 117 PCT 6
P2 BW2
-1.03 TEH TEC 0.61 CBAY2 42 C
30 0
11 116 71 0.23 98 PCT 9
P2 VS2 0.92 TEH TEC 0.61 CBAY2 6
C 60 0
11 126 71 0.29 110 PCT 11 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 6
C 38 0
11 126 71 0.4 63 PCT 14 P2 BW2
-0.99 TEH TEC 0.61 CBAY2 6
C 38 0
11 128 71 0.43 95 PCT 15 P2 VS2 0.89 TEH TEC 0.61 CBAY2 6
C 37 0
11 128 71 0.37 105 PCT 13 P2 VS3 0.82 TEH TEC 0.61 CBAY2 6
C 37 0
11 128 71 0.27 86 PCT 11 P2 BW2
-0.89 TEH TEC 0.61 CBAY2 6
C 37 0
11 162 71 0.25 50 PCT 10 P2 BW2 0.9 TEH TEC 0.61 CBAY2 56 C
62 0
11 73 72 0.22 156 NQI P1 FDP 12.34 TEH TEC 0.61 CBAY2 42 C
7 0
11 73 72 0.16 124 NQI P1 TSC 5.8 TEH TEC 0.61 CBAY2 42 C
7 0
11 73 72 0.06 85 NQI P1 TSC 8.1 TEH TEC 0.61 CBAY2 42 C
7 0
11 73 72 NDF P16 FDP 12.34 01C TEC 0.61 NYAX2 58 C
17 0
11 73 72 NDF P17 TSC 5.8 01C TEC 0.61 NYAX2 58 C
17 0
11 73 72 NDF P43 TSC 8.1 01C TEC 0.61 NYAX2 58 C
17 0
11 129 72 0.33 88 PCT 10 P2 VS2 0.92 TEH TEC 0.61 CBAY2 8
C 28 0
11 153 72 2.01 177 DNT P1 VS2 1.1 TEH TEC 0.61 CBAY2 56 C
27 0
11 153 72 NDF P4 VS2 1.1 VS3 TEH 0.61 NYAX2 67 H
17 0
11 157 72 0.37 63 PCT 13 P2 VS1
-0.73 TEH TEC 0.61 CBAY2 56 C
58 0
11 32 73 0.81 75 MBM 6
08C 10.84 TEH TEC 0.61 CBAY2 48 C
137 0
11 128 73 0.62 103 PCT 16 P2 VS2 0.95 TEH TEC 0.61 CBAY2 8
C 13 0
11 164 73 0.3 124 PCT 11 P2 BW2
-0.96 TEH TEC 0.61 CBAY2 56 C
51 0
11 41 74 0.21 35 PCT 9
P2 VS3 0.84 TEH TEC 0.61 CBAY2 48 C
111 0
11 45 74 0.22 56 PCT 9
P2 VS3 0.92 TEH TEC 0.61 CBAY2 48 C
110 0
11 47 74 0.23 46 PCT 10 P2 BW1 0.94 TEH TEC 0.61 CBAY2 48 C
109 0
11 57 74 0.15 39 PCT 7
P2 VS3 0.84 TEH TEC 0.61 CBAY2 48 C
104 0
11 59 74 0.31 49 PCT 12 P2 BW1 0.9 TEH TEC 0.61 CBAY2 48 C
103 0
11 67 74 1.5 155 NQI P1 TSH 0.37 TEH TEC 0.61 CBAY2 40 C
7 0
11 67 74 NDF P18 TSH 0.37 01H TEH 0.61 NYAX2 65 H
50 0
11 155 74 0.27 114 PCT 10 P2 VS2
-0.76 TEH TEC 0.61 CBAY2 56 C
45 0
11 163 74 0.24 46 PCT 10 P2 VS5
-0.23 TEH TEC 0.61 CBAY2 56 C
49 0
11 165 74 0.38 179 NQI P1 TSH 0.81 TEH TEC 0.61 CBAY2 56 C
50 0
11 165 74 NDF P7 TSH 0.81 01H TEH 0.61 NYAX2 67 H
40 0
11 20 75 0.27 115 PCT 10 P2 BW1 0.88 TEC TEH 0.61 CBAY2 9
H 135 4
11 34 75 0.24 88 PCT 10 P2 BW1
-1.41 TEC TEH 0.61 CBAY2 11 H
106 0
11 40 75 0.64 99 PCT 19 P2 BW1
-0.92 TEC TEH 0.61 CBAY2 9
H 20 0
11 40 75 1.48 97 WAR 23 0.23 P9 BW1
-0.82 VS3 TEH 0.61 NYAX2 65 H
28 F
0 11 42 75 0.77 92 MBM 6
FDP 6.11 TEC TEH 0.61 CBAY2 11 H
103 0
11 44 75 0.26 40 PCT 11 P2 BW1
-0.93 TEC TEH 0.61 CBAY2 11 H
13 0
11 46 75 0.24 112 PCT 10 P2 BW1
-0.91 TEC TEH 0.61 CBAY2 11 H
102 0
11 48 75 0.3 66 PCT 12 P2 VS3
-1.04 TEC TEH 0.61 CBAY2 11 H
101 0
11 90 75 0.29 92 PCT 13 P2 10H
-1.09 TEC TEH 0.61 CBAY2 23 H
57 0
11 126 75 0.24 87 PCT 10 P2 VS2 1.09 TEH TEC 0.61 CBAY2 6
C 16 0
11 134 75 0.45 108 PCT 15 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 6
C 12 0
11 136 75 0.31 130 PCT 11 P2 VS4
-0.94 TEC TEH 0.61 CBAY2 29 H
114 0
11 140 75 0.27 130 PCT 10 P2 VS1
-0.44 TEC TEH 0.61 CBAY2 29 H
116 0
11 144 75 0.46 107 PCT 15 P2 VS5
-1.22 TEC TEH 0.61 CBAY2 29 H
118 0
SG 11 Summary Data Sheets Page 9 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 160 75 0.54 100 PCT 17 P2 BW2
-0.81 TEC TEH 0.61 CBAY2 29 H
126 0
11 164 75 1.23 103 PCT 27 P2 BW2
-0.84 TEC TEH 0.61 CBAY2 29 H
128 0
11 164 75 2.71 121 WAR 30 0.21 P29 BW2
-0.84 VS3 TEC 0.61 NYAX2 64 C
6 F
0 11 164 75 1.94 109 PLP 140 09C 34.2 VS3 TEC 0.61 NYAX2 64 C
6 HR 0
11 21 76 0.27 68 PCT 10 P2 BW1
-0.13 TEC TEH 0.61 CBAY2 9
H 133 3
11 25 76 0.88 91 MBM 6
05H 32.71 TEC TEH 0.61 CBAY2 9
H 138 5
11 25 76 0.77 82 MBM 6
07H 3.01 TEC TEH 0.61 CBAY2 9
H 138 5
11 25 76 0.27 103 PCT 10 P2 BW1 1.02 TEC TEH 0.61 CBAY2 9
H 138 5
11 35 76 0.21 48 PCT 9
P2 VS3 0.68 TEC TEH 0.61 CBAY2 11 H
117 0
11 45 76 0.32 103 PCT 13 P2 VS3 0.78 TEC TEH 0.61 CBAY2 11 H
12 0
11 47 76 1.08 102 PCT 28 P2 BW1 0.91 TEC TEH 0.61 CBAY2 11 H
121 0
11 47 76 3.35 91 WAR 33 0.23 P23 BW1 0.92 VS3 TEH 0.61 NYAX2 65 H
27 F
0 11 49 76 0.2 119 PCT 9
P2 BW1
-1.18 TEC TEH 0.61 CBAY2 11 H
122 0
11 57 76 0.23 51 PCT 10 P2 BW1 2.67 TEC TEH 0.61 CBAY2 11 H
126 0
11 103 76 0.25 88 PCT 11 P2 BW1
-0.87 TEC TEH 0.61 CBAY2 23 H
48 0
11 103 76 0.16 130 PCT 8
P2 VS4 0.84 TEC TEH 0.61 CBAY2 23 H
48 0
11 161 76 0.25 93 PCT 10 P2 VS1
-0.87 TEC TEH 0.61 CBAY2 29 H
131 0
11 163 76 1.51 114 PCT 31 P2 BW2
-0.8 TEC TEH 0.61 CBAY2 29 H
130 0
11 163 76 2.44 97 WAR 28 0.29 P28 BW2
-0.65 VS3 TEC 0.61 NYAX2 64 C
19 F
0 11 163 76 PID P2 BW2
-0.8 TEH TEC 0.61 CBAY2 276 C
8 0
11 165 76 0.83 123 PCT 22 P2 BW2
-0.82 TEC TEH 0.61 CBAY2 29 H
129 0
11 165 76 1.06 108 WAR 20 0.23 P47 BW2
-0.9 VS3 TEC 0.61 NYAX2 64 C
7 T
0 11 165 76 NDF P40 09C 33.12 VS3 TEC 0.61 NYAX2 64 C
7 0
11 26 77 0.44 137 PCT 15 P2 BW2 0.9 TEC TEH 0.61 CBAY2 9
H 132 3
11 44 77 0.19 132 PCT 8
P2 BW1
-0.93 TEC TEH 0.61 CBAY2 9
H 124 0
11 46 77 0.23 131 PCT 10 P2 BW1
-1.02 TEC TEH 0.61 CBAY2 11 H
11 0
11 82 77 0.33 93 PCT 12 P2 VS2
-0.16 TEC TEH 0.61 CBAY2 33 H
112 0
11 90 77 0.42 99 PCT 14 P2 10H
-0.38 TEC TEH 0.61 CBAY2 33 H
109 0
11 140 77 0.22 141 PCT 10 P2 VS1
-0.82 TEC TEH 0.61 CBAY2 31 H
147 0
11 150 77 0.49 53 PCT 18 P2 BW2 0.87 TEC TEH 0.61 CBAY2 31 H
152 15 0
11 154 77 0.28 68 PCT 12 P2 VS2 0.74 TEC TEH 0.61 CBAY2 31 H
154 0
11 156 77 0.38 151 PCT 15 P2 BW2 0.95 TEC TEH 0.61 CBAY2 31 H
155 9
0 11 164 77 0.53 93 PCT 19 P2 BW1 0.84 TEC TEH 0.61 CBAY2 31 H
159 0
11 166 77 0.35 104 PCT 14 P2 BW2
-0.73 TEC TEH 0.61 CBAY2 31 H
160 0
11 27 78 0.34 96 PCT 12 P2 VS3 0.95 TEC TEH 0.61 CBAY2 9
H 150 3
11 47 78 0.35 112 PCT 14 P2 BW1 0.9 TEC TEH 0.61 CBAY2 11 H
10 0
11 75 78 0.75 121 XPI P17 TSH 0.79 01H TEH 0.61 NYAX2 63 H
89 0
11 75 78 0.7 320 DEP 2
TSH 0.8 TSH TSH 0.6 NPAHZ 71 H
11 0
11 77 78 0.83 30 NQI P1 TSH 0.36 TEC TEH 0.61 CBAY2 21 H
73 0
11 77 78 NDF P17 TSH 0.36 01H TEH 0.61 NYAX2 63 H
88 0
11 89 78 1.64 183 DNT P1 VS4 10.95 TEC TEH 0.61 CBAY2 21 H
67 0
11 95 78 0.33 50 PCT 12 P2 BW2
-0.02 TEC TEH 0.61 CBAY2 33 H
115 0
11 117 78 0.22 45 PCT 10 P2 VS1
-0.77 TEC TEH 0.61 CBAY2 31 H
185 0
11 125 78 0.5 110 PCT 18 P2 VS2
-0.93 TEC TEH 0.61 CBAY2 31 H
181 0
11 125 78 0.3 67 PCT 13 P2 VS5
-0.95 TEC TEH 0.61 CBAY2 31 H
181 0
11 163 78 0.47 113 PCT 17 P2 BW2 0.94 TEC TEH 0.61 CBAY2 31 H
162 0
11 165 78 0.24 118 PCT 11 P2 BW2 1.07 TEC TEH 0.61 CBAY2 31 H
161 0
11 30 79 0.62 100 PCT 20 P2 VS3
-0.7 TEC TEH 0.61 CBAY2 11 H
148 3
11 30 79 0.24 141 PCT 10 P2 BW2 1.05 TEC TEH 0.61 CBAY2 11 H
148 3
11 30 79 1.11 122 WAR 20 0.17 P21 VS3
-0.96 VS3 TEH 0.61 NYAX2 69 H
25 F
3 11 30 79 TBP TEH TEC 0.61 CBAY2 274 C
19 3
11 30 79 PID P2 VS3
-0.7 TEH TEC 0.61 CBAY2 274 C
19 3
SG 11 Summary Data Sheets Page 10 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 32 79 4.81 108 PLP 8
TSH 0.5 TEC TEH 0.61 CBAY2 11 H
147 HR 4
11 32 79 0.32 84 PCT 13 P2 VS3
-0.67 TEC TEH 0.61 CBAY2 11 H
147 4
11 32 79 9.75 139 PLP 135 TSH 0.22 01H TEH 0.61 NYAX2 65 H
18 HR 4
11 34 79 0.28 76 PCT 11 P2 VS3
-0.72 TEC TEH 0.61 CBAY2 11 H
146 5
11 38 79 0.13 79 PCT 6
P2 VS3
-0.94 TEC TEH 0.61 CBAY2 11 H
144 7
11 42 79 0.35 94 PCT 13 P2 VS3
-0.67 TEC TEH 0.61 CBAY2 11 H
143 0
11 44 79 0.45 119 PCT 15 P2 VS3
-0.91 TEC TEH 0.61 CBAY2 9
H 16 0
11 44 79 0.31 114 PCT 11 P2 VS3
-0.62 TEC TEH 0.61 CBAY2 9
H 16 0
11 50 79 0.31 107 PCT 13 P2 VS3 0.8 TEC TEH 0.61 CBAY2 11 H
141 0
11 64 79 3.35 183 DNT P1 BW2 1.88 TEC TEH 0.61 CBAY2 1
H 20 0
11 64 79 NDF P1 BW2 1.88 VS3 TEC 0.61 NYAX2 62 C
12 0
11 90 79 0.28 22 PCT 11 P2 10H
-1.21 TEC TEH 0.61 CBAY2 23 H
69 0
11 132 79 0.17 26 PCT 7
P2 11H
-1.34 TEC TEH 0.61 CBAY2 29 H
167 0
11 144 79 0.28 99 PCT 10 P2 VS2 1.17 TEC TEH 0.61 CBAY2 29 H
175 0
11 164 79 0.31 87 PCT 11 P2 BW1 1
TEC TEH 0.61 CBAY2 29 H
185 0
11 164 79 0.54 108 PCT 17 P2 BW2
-0.87 TEC TEH 0.61 CBAY2 29 H
185 0
11 33 80 9.5 267 PLP 8
TSH 0.69 TEC TEH 0.61 CBAY2 11 H
149 HR 3
11 33 80 2.42 125 PLP 11 TSH 0.66 01H TEH 0.61 NYAX2 65 H
12 HR 3
11 35 80 0.28 106 PCT 11 P2 BW1
-1.22 TEC TEH 0.61 CBAY2 11 H
150 4
11 43 80 0.24 40 PCT 10 P2 BW1 1.04 TEC TEH 0.61 CBAY2 11 H
154 8
11 47 80 0.59 93 PCT 19 P2 BW1 0.84 TEC TEH 0.61 CBAY2 11 H
155 0
11 47 80 1.56 85 WAR 23 0.2 P23 BW1 0.94 VS3 TEH 0.61 NYAX2 65 H
15 F
0 11 49 80 0.28 131 PCT 12 P2 BW1
-0.91 TEC TEH 0.61 CBAY2 11 H
8 0
11 77 80 0.12 319 PCT 6
P2 VS4 0.9 TEC TEH 0.61 CBAY2 23 H
96 0
11 115 80 0.26 108 PCT 10 P2 BW1 0.91 TEC TEH 0.61 CBAY2 33 H
31 0
11 115 80 0.28 134 PCT 11 P2 VS1
-0.87 TEC TEH 0.61 CBAY2 33 H
31 0
11 125 80 0.87 123 PCT 23 P2 VS3
-0.83 TEC TEH 0.61 CBAY2 33 H
26 5
0 11 125 80 2.1 281 WAR 27 0.47 P11 VS3
-0.83 VS3 TEH 0.61 NYAX2 67 H
16 F
0 11 167 80 1.51 104 PCT 31 P2 BW2
-0.9 TEC TEH 0.61 CBAY2 33 H
5 0
11 167 80 3.16 109 WAR 32 0.39 P28 BW2
-0.71 VS3 TEC 0.61 NYAX2 64 C
10 T
0 11 167 80 PID P2 BW2
-0.9 TEH TEC 0.61 CBAY2 276 C
9 0
11 36 81 0.41 105 PCT 14 P2 BW1
-1.01 TEC TEH 0.61 CBAY2 9
H 183 4
11 38 81 0.55 119 PCT 17 P2 BW1
-0.85 TEC TEH 0.61 CBAY2 9
H 182 5
11 46 81 0.17 137 PCT 7
P2 VS3
-0.38 TEC TEH 0.61 CBAY2 9
H 14 0
11 48 81 0.21 122 PCT 9
P2 09C
-1.17 TEC TEH 0.61 CBAY2 9
H 178 0
11 60 81 0.64 117 PCT 19 P2 BW1 0.83 TEC TEH 0.61 CBAY2 9
H 173 0
11 60 81 1.72 98 WAR 25 0.2 P23 BW1 0.85 VS3 TEH 0.61 NYAX2 65 H
9 F
0 11 78 81 0.31 108 PCT 12 P2 VS2 0.84 TEC TEH 0.61 CBAY2 21 H
74 0
11 82 81 0.16 54 PCT 8
P2 VS3 0.92 TEC TEH 0.61 CBAY2 21 H
76 0
11 116 81 0.26 50 PCT 11 P2 BW1
-0.99 TEC TEH 0.61 CBAY2 31 H
191 0
11 118 81 0.31 104 PCT 13 P2 BW1
-0.95 TEC TEH 0.61 CBAY2 31 H
192 0
11 118 81 0.34 91 PCT 14 P2 VS1
-0.84 TEC TEH 0.61 CBAY2 31 H
192 0
11 120 81 0.26 111 PCT 11 P2 BW1
-0.72 TEC TEH 0.61 CBAY2 31 H
193 0
11 122 81 0.32 75 PCT 13 P2 BW2 1.01 TEC TEH 0.61 CBAY2 31 H
194 0
11 124 81 0.32 141 PCT 13 P2 BW2 1.06 TEC TEH 0.61 CBAY2 31 H
195 0
11 134 81 0.22 138 PCT 10 P2 VS1
-0.76 TEC TEH 0.61 CBAY2 31 H
200 0
11 136 81 1.02 109 PCT 27 P2 VS2 0.75 TEC TEH 0.61 CBAY2 31 H
201 0
11 136 81 2.9 103 WAR 31 0.43 P12 VS2 0.96 VS3 TEH 0.61 NYAX2 67 H
15 F
0 11 156 81 0.32 137 PCT 13 P2 BW2 1
TEC TEH 0.61 CBAY2 31 H
213 0
11 164 81 0.4 74 PCT 15 P2 BW1 0.85 TEC TEH 0.61 CBAY2 31 H
217 0
11 164 81 0.37 100 PCT 15 P2 VS4 0.96 TEC TEH 0.61 CBAY2 31 H
217 12 0
11 164 81 0.34 70 PCT 14 P2 BW2 1
TEC TEH 0.61 CBAY2 31 H
217 0
SG 11 Summary Data Sheets Page 11 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 168 81 0.71 96 PCT 20 P2 BW2
-0.77 TEC TEH 0.61 CBAY2 29 H
187 0
11 168 81 1.34 126 WAR 22 0.19 P28 BW2
-0.83 VS3 TEC 0.61 NYAX2 64 C
9 F
0 11 37 82 0.39 108 PCT 13 P2 BW1
-0.94 TEC TEH 0.61 CBAY2 9
H 184 3
11 43 82 0.91 120 PCT 23 P2 BW1 1.15 TEC TEH 0.61 CBAY2 9
H 187 6
11 43 82 1.85 125 WAR 25 0.21 P24 BW1 0.94 VS3 TEH 0.61 NYAX2 65 H
8 F
6 11 43 82 PID P2 BW1 1.15 TEH TEC 0.61 CBAY2 274 C
18 6
11 45 82 0.25 121 PCT 10 P2 BW1 1.11 TEC TEH 0.61 CBAY2 9
H 188 7
11 49 82 0.82 93 PCT 22 P2 BW1 1.01 TEC TEH 0.61 CBAY2 9
H 189 0
11 49 82 2.2 97 WAR 27 0.2 P23 BW1 0.99 VS3 TEH 0.61 NYAX2 65 H
7 F
0 11 111 82 0.26 60 PCT 11 P2 BW1 0.85 TEC TEH 0.61 CBAY2 35 H
34 0
11 121 82 0.25 144 PCT 11 P2 BW2
-0.71 TEC TEH 0.61 CBAY2 35 H
29 0
11 129 82 0.43 69 PCT 16 P2 VS2
-0.7 TEC TEH 0.61 CBAY2 35 H
25 0
11 167 82 0.32 67 PCT 13 P2 BW1
-0.73 TEC TEH 0.61 CBAY2 35 H
5 0
11 167 82 0.57 91 PCT 20 P2 BW2
-0.88 TEC TEH 0.61 CBAY2 35 H
5 0
11 167 82 1.3 126 WAR 22 0.29 P27 BW2
-0.83 VS3 TEC 0.61 NYAX2 64 C
20 F
0 11 40 83 0.27 86 PCT 12 P2 BW1
-0.87 TEC TEH 0.61 CBAY2 15 H
16 4
11 42 83 0.39 93 PCT 15 P2 BW1
-0.94 TEC TEH 0.61 CBAY2 15 H
15 5
11 44 83 0.32 136 PCT 13 P2 BW1
-1.1 TEC TEH 0.61 CBAY2 15 H
14 6
11 44 83 0.49 114 PCT 18 P2 BW1 0.98 TEC TEH 0.61 CBAY2 15 H
14 6
11 48 83 0.51 112 PCT 16 P2 BW1 0.97 TEC TEH 0.61 CBAY2 9
H 13 8
11 48 83 0.29 90 PCT 11 P2 VS3
-1.02 TEC TEH 0.61 CBAY2 9
H 13 8
11 50 83 0.25 51 PCT 11 P2 VS3
-0.87 TEC TEH 0.61 CBAY2 15 H
12 0
11 56 83 0.24 122 PCT 9
P2 BW1 1.99 TEC TEH 0.61 CBAY2 5
H 134 0
11 90 83 0.19 93 PCT 9
P2 10H
-1.23 TEC TEH 0.61 CBAY2 23 H
103 0
11 94 83 0.24 83 PCT 11 P2 BW1
-0.79 TEC TEH 0.61 CBAY2 23 H
105 0
11 140 83 0.28 83 PCT 10 P2 BW2
-0.81 TEC TEH 0.61 CBAY2 33 H
48 0
11 142 83 0.57 128 PCT 18 P2 VS2
-0.92 TEC TEH 0.61 CBAY2 33 H
49 0
11 166 83 0.61 97 PCT 18 P2 BW1 0.9 TEC TEH 0.61 CBAY2 33 H
61 0
11 43 84 0.24 141 PCT 9
P2 BW1 0.82 TEC TEH 0.61 CBAY2 5
H 114 5
11 45 84 0.62 80 PCT 18 P2 BW1 0.84 TEC TEH 0.61 CBAY2 5
H 115 6
11 45 84 0.38 91 PCT 13 P2 BW2
-0.78 TEC TEH 0.61 CBAY2 5
H 115 6
11 51 84 0.28 42 PCT 10 P2 BW1
-0.9 TEC TEH 0.61 CBAY2 5
H 117 0
11 55 84 0.65 110 PCT 19 P2 BW1 1.59 TEC TEH 0.61 CBAY2 5
H 119 0
11 61 84 0.32 132 PCT 11 P2 VS3 0.73 TEC TEH 0.61 CBAY2 1
H 28 0
11 83 84 0.19 29 PCT 9
P2 VS2 0.8 TEC TEH 0.61 CBAY2 23 H
127 0
11 40 85 0.4 113 PCT 13 P2 BW1 0.96 TEC TEH 0.61 CBAY2 13 H
12 3
11 40 85 0.55 119 PCT 16 P2 VS3 0.74 TEC TEH 0.61 CBAY2 13 H
12 3
11 48 85 0.43 117 PCT 14 P2 09C
-1.18 TEC TEH 0.61 CBAY2 5
H 111 7
11 52 85 0.38 115 PCT 13 P2 BW2 0.81 TEC TEH 0.61 CBAY2 5
H 109 0
11 58 85 0.18 110 PCT 7
P2 VS3 0.77 TEC TEH 0.61 CBAY2 5
H 103 0
11 80 85 0.22 88 PCT 10 P2 BW2 0.99 TEC TEH 0.61 CBAY2 21 H
108 0
11 98 85 0.27 31 PCT 10 P2 BW2 1.08 TEC TEH 0.61 CBAY2 33 H
130 0
11 126 85 0.33 55 PCT 14 P2 BW1
-0.6 TEC TEH 0.61 CBAY2 35 H
42 0
11 132 85 0.21 80 PCT 10 P2 11C
-1.18 TEC TEH 0.61 CBAY2 35 H
45 0
11 41 86 0.47 88 PCT 17 P2 BW1
-1.17 TEC TEH 0.61 CBAY2 11 H
34 3
11 41 86 0.42 120 PCT 16 P2 BW2
-0.99 TEC TEH 0.61 CBAY2 11 H
34 3
11 45 86 0.53 113 PCT 18 P2 BW1 0.88 TEC TEH 0.61 CBAY2 7
H 112 5
11 45 86 0.25 88 PCT 11 P2 BW2
-0.97 TEC TEH 0.61 CBAY2 7
H 112 5
11 47 86 0.4 123 PCT 15 P2 BW1
-0.91 TEC TEH 0.61 CBAY2 7
H 113 6
11 47 86 0.27 141 PCT 12 P2 BW2 1.16 TEC TEH 0.61 CBAY2 7
H 113 6
11 49 86 0.29 124 PCT 12 P2 BW1
-0.86 TEC TEH 0.61 CBAY2 7
H 114 7
11 49 86 0.4 117 PCT 15 P2 BW2
-0.96 TEC TEH 0.61 CBAY2 7
H 114 7
SG 11 Summary Data Sheets Page 12 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 109 86 0.27 57 PCT 11 P2 VS2
-1.06 TEC TEH 0.61 CBAY2 21 H
124 0
11 129 86 0.29 91 PCT 12 P2 BW2 1.1 TEC TEH 0.61 CBAY2 35 H
82 0
11 153 86 0.3 122 PCT 13 P2 VS2
-0.95 TEC TEH 0.61 CBAY2 35 H
70 0
11 44 87 0.38 129 PCT 15 P2 BW1 0.93 TEC TEH 0.61 CBAY2 7
H 111 4
11 46 87 0.37 120 PCT 14 P2 BW1 0.98 TEC TEH 0.61 CBAY2 7
H 110 5
11 130 87 0.25 107 PCT 10 P2 VS1 0.7 TEC TEH 0.61 CBAY2 33 H
152 0
11 146 87 0.32 109 PCT 12 P2 BW1
-0.7 TEC TEH 0.61 CBAY2 33 H
144 0
11 160 87 0.25 102 PCT 10 P2 BW1
-0.91 TEC TEH 0.61 CBAY2 33 H
138 0
11 47 88 0.45 112 PCT 15 P2 BW1 0.84 TEC TEH 0.61 CBAY2 9
H 24 5
11 49 88 0.5 85 PCT 17 P2 BW1
-0.93 TEC TEH 0.61 CBAY2 11 H
16 6
11 49 88 0.65 83 PCT 21 P2 BW1 0.84 TEC TEH 0.61 CBAY2 11 H
16 6
11 49 88 1.34 283 WAR 22 P8 BW1
-1.08 VS3 TEH 0.61 NYAX2 65 H
6 6
11 49 88 2.09 89 WAR 27 0.2 P23 BW1 0.86 VS3 TEH 0.61 NYAX2 65 H
6 F
6 11 49 88 PID P2 BW1 0.84 TEH TEC 0.61 CBAY2 274 C
17 6
11 51 88 0.23 82 PCT 10 P2 BW1 0.93 TEC TEH 0.61 CBAY2 11 H
19 7
11 75 88 0.22 105 PCT 9
P2 BW1 0.9 TEC TEH 0.61 CBAY2 5
H 96 0
11 75 88 0.38 32 PCT 13 P2 VS2 0.76 TEC TEH 0.61 CBAY2 5
H 96 0
11 83 88 0.14 48 PCT 7
P2 VS2 0.7 TEC TEH 0.61 CBAY2 23 H
160 0
11 111 88 0.16 96 PCT 7
P2 BW1
-0.61 TEC TEH 0.61 CBAY2 33 H
161 0
11 133 88 0.38 54 PCT 13 P2 BW1
-0.83 TEC TEH 0.61 CBAY2 33 H
172 0
11 161 88 0.37 131 PCT 13 P2 VS1
-0.82 TEC TEH 0.61 CBAY2 33 H
186 0
11 163 88 0.33 113 PCT 12 P2 VS5 0.87 TEC TEH 0.61 CBAY2 33 H
187 0
11 165 88 0.27 129 PCT 10 P2 VS5 0.91 TEC TEH 0.61 CBAY2 33 H
188 0
11 46 89 0.34 69 PCT 12 P2 BW1
-1.17 TEC TEH 0.61 CBAY2 9
H 21 4
11 46 89 0.67 102 PCT 19 P2 BW1 1.11 TEC TEH 0.61 CBAY2 9
H 21 4
11 56 89 0.28 90 PCT 10 P2 VS3
-0.92 TEC TEH 0.61 CBAY2 9
H 6
0 11 56 89 0.55 91 MBM 6
02C 6.08 TEC TEH 0.61 CBAY2 9
H 6
0 11 82 89 0.4 99 PCT 15 P2 BW1
-1.03 TEC TEH 0.61 CBAY2 21 H
142 0
11 122 89 0.25 56 PCT 11 P2 BW1
-0.95 TEC TEH 0.61 CBAY2 35 H
114 0
11 128 89 0.2 54 PCT 10 P2 BW1 0.87 TEC TEH 0.61 CBAY2 35 H
111 0
11 140 89 0.2 41 PCT 9
P2 BW1 0.82 TEC TEH 0.61 CBAY2 35 H
105 0
11 142 89 0.23 25 PCT 11 P2 BW1 0.85 TEC TEH 0.61 CBAY2 35 H
104 0
11 144 89 0.42 51 PCT 16 P2 BW1 0.82 TEC TEH 0.61 CBAY2 35 H
103 0
11 144 89 0.37 40 PCT 15 P2 BW2
-0.8 TEC TEH 0.61 CBAY2 35 H
103 0
11 156 89 0.2 86 PCT 10 P2 BW1 0.82 TEC TEH 0.61 CBAY2 35 H
97 0
11 156 89 0.28 76 PCT 12 P2 VS3 0.69 TEC TEH 0.61 CBAY2 35 H
97 0
11 158 89 0.24 37 PCT 11 P2 VS1
-0.9 TEC TEH 0.61 CBAY2 35 H
96 0
11 168 89 0.31 105 PCT 11 P2 BW2
-0.87 TEC TEH 0.61 CBAY2 33 H
192 0
11 83 90 0.48 135 PCT 13 P2 09H 0.84 TEC TEH 0.61 CBAY2 25 H
7 0
11 87 90 0.27 68 PCT 11 P2 BW2 0
TEC TEH 0.61 CBAY2 25 H
9 0
11 103 90 0.25 109 PCT 10 P2 BW1
-0.89 TEC TEH 0.61 CBAY2 25 H
17 0
11 115 90 0.33 63 PCT 14 P2 VS2
-0.93 TEC TEH 0.61 CBAY2 35 H
122 0
11 115 90 0.29 80 PCT 12 P2 VS3
-0.9 TEC TEH 0.61 CBAY2 35 H
122 0
11 121 90 0.26 76 PCT 12 P2 BW1 0.85 TEC TEH 0.61 CBAY2 35 H
125 0
11 121 90 0.21 54 PCT 10 P2 VS4 0.92 TEC TEH 0.61 CBAY2 35 H
125 0
11 125 90 0.36 41 PCT 15 P2 VS1 0.69 TEC TEH 0.61 CBAY2 35 H
127 12 0
11 127 90 0.28 88 PCT 12 P2 VS1
-0.85 TEC TEH 0.61 CBAY2 35 H
128 0
11 127 90 0.27 40 PCT 12 P2 BW2 1.05 TEC TEH 0.61 CBAY2 35 H
128 0
11 143 90 0.25 49 PCT 11 P2 VS1 0.66 TEC TEH 0.61 CBAY2 35 H
136 0
11 161 90 0.25 26 PCT 11 P2 VS1
-0.99 TEC TEH 0.61 CBAY2 35 H
145 0
11 161 90 0.29 52 PCT 12 P2 VS4 0.91 TEC TEH 0.61 CBAY2 35 H
145 0
11 161 90 0.24 47 PCT 11 P2 VS5 0.76 TEC TEH 0.61 CBAY2 35 H
145 0
SG 11 Summary Data Sheets Page 13 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 163 90 0.24 75 PCT 11 P2 VS4 0.86 TEC TEH 0.61 CBAY2 35 H
146 0
11 167 90 1.5 89 PCT 33 P2 BW2
-0.8 TEC TEH 0.61 CBAY2 35 H
148 0
11 167 90 0.46 64 PCT 17 P2 BW2
-0.13 TEC TEH 0.61 CBAY2 35 H
148 0
11 167 90 2.45 115 WAR 29 0.26 P26 BW2
-0.79 VS3 TEC 0.61 NYAX2 64 C
21 F
0 11 167 90 1.13 135 WAR 20 0.17 P26 BW2
-0.03 VS3 TEC 0.61 NYAX2 64 C
21 F
0 11 167 90 PID P2 BW2
-0.8 TEH TEC 0.61 CBAY2 276 C
10 0
11 48 91 0.29 97 PCT 11 P2 VS3
-0.84 TEC TEH 0.61 CBAY2 9
H 22 4
11 48 91 0.24 58 PCT 9
P2 BW2 0.96 TEC TEH 0.61 CBAY2 9
H 22 4
11 48 91 0.5 111 PCT 16 P2 09C
-0.97 TEC TEH 0.61 CBAY2 9
H 22 4
11 52 91 0.4 113 PCT 15 P2 VS3
-1.01 TEC TEH 0.61 CBAY2 11 H
33 6
11 80 91 0.84 96 PCT 25 P2 BW1
-0.86 TEC TEH 0.61 CBAY2 23 H
164 0
11 80 91 2.65 109 WAR 29 0.17 P23 BW1
-0.77 VS3 TEH 0.61 NYAX2 63 H
68 F
0 11 82 91 0.56 100 PCT 19 P2 VS3 0.83 TEC TEH 0.61 CBAY2 23 H
165 0
11 90 91 0.19 112 PCT 9
P2 10C
-1.69 TEC TEH 0.61 CBAY2 23 H
169 0
11 126 91 0.38 103 PCT 13 P2 VS2 1.14 TEC TEH 0.61 CBAY2 33 H
216 0
11 126 91 0.25 131 PCT 10 P2 BW2 0
TEC TEH 0.61 CBAY2 33 H
216 0
11 130 91 0.44 82 PCT 15 P2 BW1 0.9 TEC TEH 0.61 CBAY2 33 H
214 0
0 11 132 91 0.55 125 PCT 17 P2 VS1 0.67 TEC TEH 0.61 CBAY2 33 H
213 9
0 11 136 91 0.4 107 PCT 14 P2 VS1
-0.46 TEC TEH 0.61 CBAY2 33 H
211 0
11 140 91 0.34 129 PCT 12 P2 VS1
-0.78 TEC TEH 0.61 CBAY2 33 H
209 0
11 142 91 0.27 132 PCT 10 P2 BW1 0.67 TEC TEH 0.61 CBAY2 33 H
208 0
11 142 91 0.13 94 DSI P1 11C
-0.41 TEC TEH 0.61 CBAY2 33 H
208 0
11 142 91 NDF P14 11C
-0.41 11C TEC 0.61 NYAX2 62 C
22 0
11 144 91 0.27 117 PCT 10 P2 BW2 0.05 TEC TEH 0.61 CBAY2 33 H
207 0
11 146 91 0.31 59 PCT 11 P2 BW2
-1 TEC TEH 0.61 CBAY2 33 H
206 0
11 152 91 0.26 97 PCT 10 P2 BW1 0.44 TEC TEH 0.61 CBAY2 33 H
203 0
11 160 91 0.25 122 PCT 10 P2 VS2 0.93 TEC TEH 0.61 CBAY2 33 H
199 0
11 49 92 0.7 122 PCT 20 P2 BW1
-0.86 TEC TEH 0.61 CBAY2 9
H 23 4
11 49 92 1.07 110 PCT 26 P2 BW1 0.85 TEC TEH 0.61 CBAY2 9
H 23 4
11 49 92 1.49 101 WAR 23 0.17 P8 BW1
-0.92 VS3 TEH 0.61 NYAX2 65 H
5 F
4 11 49 92 2.86 96 WAR 30 0.19 P23 BW1 0.88 VS3 TEH 0.61 NYAX2 65 H
5 F
4 11 49 92 TBP TEH TEC 0.61 CBAY2 274 C
16 4
11 49 92 PID P2 BW1 0.85 TEH TEC 0.61 CBAY2 274 C
16 4
11 55 92 0.23 114 PCT 10 P2 BW1 1.92 TEC TEH 0.61 CBAY2 11 H
23 7
11 59 92 0.32 99 PCT 11 P2 VS2
-0.68 TEC TEH 0.61 CBAY2 5
H 87 0
11 63 92 0.31 122 PCT 11 P2 BW2
-0.72 TEC TEH 0.61 CBAY2 1
H 55 0
11 107 92 0.26 127 PCT 11 P2 BW1
-1.42 TEC TEH 0.61 CBAY2 27 H
20 0
11 113 92 0.36 94 PCT 13 P2 VS1
-0.86 TEC TEH 0.61 CBAY2 33 H
225 0
11 117 92 0.33 132 PCT 12 P2 VS1
-0.77 TEC TEH 0.61 CBAY2 33 H
227 0
11 117 92 3.19 184 DNT P1 VS5
-0.77 TEC TEH 0.61 CBAY2 33 H
227 0
11 117 92 NDF P19 VS5
-0.77 VS3 TEC 0.61 NYAX2 62 C
19 0
11 129 92 0.24 46 PCT 10 P2 BW2 0.96 TEC TEH 0.61 CBAY2 33 H
233 0
11 131 92 0.27 94 PCT 10 P2 VS1 0.9 TEC TEH 0.61 CBAY2 33 H
234 0
11 131 92 0.29 75 PCT 11 P2 BW2 0.36 TEC TEH 0.61 CBAY2 33 H
234 0
11 169 92 0.22 32 PCT 10 P2 BW2
-0.83 TEC TEH 0.61 CBAY2 35 H
149 0
11 48 93 1.16 101 PCT 29 P2 BW1
-0.91 TEC TEH 0.61 CBAY2 11 H
36 3
11 48 93 2.89 97 WAR 31 0.41 P9 BW1
-1.39 VS3 TEH 0.61 NYAX2 65 H
4 T
3 11 48 93 TBP TEH TEC 0.61 CBAY2 274 C
15 3
11 48 93 PID P2 BW1
-0.91 TEH TEC 0.61 CBAY2 274 C
15 3
11 90 93 0.19 78 PCT 8
P2 10H
-1.32 TEC TEH 0.61 CBAY2 25 H
31 0
11 132 93 1.03 125 PCT 25 P2 11C
-1.62 TEC TEH 0.61 CBAY2 35 H
170 0
11 132 93 1.58 113 WAR 24 0.13 P30 11C
-1.3 11C TEC 0.61 NYAX2 62 C
21 F
0 SG 11 Summary Data Sheets Page 14 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 150 93 0.28 44 PCT 12 P2 VS1 0.82 TEC TEH 0.61 CBAY2 35 H
161 0
11 166 93 0.22 33 PCT 10 P2 VS2 0.92 TEC TEH 0.61 CBAY2 35 H
152 0
11 168 93 0.8 121 PCT 24 P2 BW2
-0.83 TEC TEH 0.61 CBAY2 35 H
150 0
11 168 93 1.71 114 WAR 24 0.3 P26 BW2
-0.94 VS3 TEC 0.61 NYAX2 64 C
22 F
0 11 49 94 0.36 71 PCT 14 P2 BW1
-0.83 TEC TEH 0.61 CBAY2 11 H
37 3
11 59 94 0.19 132 PCT 9
P2 BW2 1.02 TEC TEH 0.61 CBAY2 7
H 85 8
11 65 94 0.22 118 PCT 8
P2 BW1 0.78 TEC TEH 0.61 CBAY2 1
H 68 0
11 65 94 0.26 101 PCT 10 P2 VS2
-0.95 TEC TEH 0.61 CBAY2 1
H 68 0
11 111 94 0.26 75 PCT 11 P2 BW1 0.88 TEC TEH 0.61 CBAY2 35 H
181 0
11 161 94 0.32 80 PCT 13 P2 VS3 0.82 TEC TEH 0.61 CBAY2 35 H
206 0
11 161 94 0.24 32 PCT 11 P2 VS5 0.75 TEC TEH 0.61 CBAY2 35 H
206 0
11 165 94 0.26 36 PCT 12 P2 VS5 0.76 TEC TEH 0.61 CBAY2 35 H
208 0
11 167 94 0.27 141 PCT 10 P2 VS4
-0.93 TEC TEH 0.61 CBAY2 33 H
254 0
11 167 94 0.55 123 PCT 17 P2 BW2 0.93 TEC TEH 0.61 CBAY2 33 H
254 0
11 58 95 0.18 55 PCT 8
P2 VS3 0.85 TEC TEH 0.61 CBAY2 11 H
26 8
11 64 95 0.31 116 PCT 11 P2 VS3 0.87 TEC TEH 0.61 CBAY2 1
H 69 0
11 68 95 0.43 100 PCT 16 P2 BW1
-0.97 TEC TEH 0.61 CBAY2 3
H 9
0 11 70 95 0.68 125 PCT 22 P2 BW1
-0.86 TEC TEH 0.61 CBAY2 7
H 74 0
11 70 95 1.78 117 WAR 25 0.16 P24 BW1
-0.89 VS3 TEH 0.61 NYAX2 65 H
10 F
0 11 128 95 0.29 50 PCT 10 P2 BW2
-0.3 TEC TEH 0.61 CBAY2 37 H
39 0
11 144 95 0.5 136 PCT 15 P2 VS2 0.91 TEC TEH 0.61 CBAY2 37 H
31 0
0 11 51 96 0.37 122 PCT 14 P2 BW1
-0.99 TEC TEH 0.61 CBAY2 11 H
38 4
11 71 96 0.26 128 PCT 10 P2 VS3
-0.93 TEC TEH 0.61 CBAY2 5
H 71 0
11 89 96 0.25 126 PCT 11 P2 VS4 0.77 TEC TEH 0.61 CBAY2 27 H
44 0
11 119 96 0.28 57 PCT 10 P2 BW1 0.95 TEC TEH 0.61 CBAY2 37 H
52 0
11 127 96 0.27 72 PCT 10 P2 VS1 0.13 TEC TEH 0.61 CBAY2 37 H
56 0
11 135 96 0.27 129 PCT 10 P2 11C
-0.79 TEC TEH 0.61 CBAY2 37 H
60 0
11 145 96 0.31 115 PCT 11 P2 BW2
-0.76 TEC TEH 0.61 CBAY2 37 H
65 0
11 145 96 0.31 118 PCT 11 P2 BW2 0.91 TEC TEH 0.61 CBAY2 37 H
65 0
11 159 96 0.31 133 PCT 11 P2 VS2
-0.79 TEC TEH 0.61 CBAY2 37 H
13 0
11 167 96 0.32 122 PCT 11 P2 VS5 0.85 TEC TEH 0.61 CBAY2 37 H
9 0
11 50 97 0.26 92 PCT 11 P2 BW1 0.98 TEC TEH 0.61 CBAY2 11 H
52 3
11 56 97 0.26 98 PCT 10 P2 BW2
-1.61 TEC TEH 0.61 CBAY2 9
H 31 6
11 90 97 0.25 122 PCT 10 P2 10H
-1.42 TEC TEH 0.61 CBAY2 25 H
64 0
11 120 97 0.24 52 PCT 11 P2 BW1
-0.76 TEC TEH 0.61 CBAY2 39 H
44 0
11 134 97 0.32 26 PCT 10 P2 11H 0.45 TEC TEH 0.61 CBAY2 39 H
37 0
11 166 97 0.39 86 PCT 15 P2 BW2 0.85 TEC TEH 0.61 CBAY2 39 H
21 0
11 49 98 0.38 109 PCT 13 P2 BW1 1.13 TEC TEH 0.61 CBAY2 9
H 41 3
11 51 98 0.23 89 PCT 10 P2 BW2
-0.93 TEC TEH 0.61 CBAY2 11 H
51 4
11 63 98 0.24 138 PCT 9
P2 VS3 0.7 TEC TEH 0.61 CBAY2 1
H 77 0
11 107 98 0.45 122 PCT 15 P2 VS4 1.04 TEC TEH 0.61 CBAY2 25 H
85 0
11 115 98 0.61 79 PCT 20 P2 VS2
-0.91 TEC TEH 0.61 CBAY2 39 H
51 0
11 115 98 1.96 107 WAR 26 0.43 P12 VS2
-0.85 VS3 TEH 0.61 NYAX2 67 H
11 F
0 11 125 98 0.23 44 PCT 10 P2 VS1 0.64 TEC TEH 0.61 CBAY2 39 H
56 0
11 139 98 0.26 90 PCT 11 P2 VS1 0.61 TEC TEH 0.61 CBAY2 39 H
63 0
11 141 98 0.38 99 PCT 15 P2 VS1 0.59 TEC TEH 0.61 CBAY2 39 H
64 9
0 11 143 98 0.62 78 PCT 21 P2 VS1 0.61 TEC TEH 0.61 CBAY2 39 H
65 0
11 143 98 1.66 105 WAR 24 0.22 P28 VS1 0.63 VS3 TEH 0.61 NYAX2 67 H
14 F
0 11 54 99 0.23 128 PCT 10 P2 BW1
-1.37 TEC TEH 0.61 CBAY2 11 H
41 5
11 56 99 0.4 109 PCT 14 P2 BW1
-1.69 TEC TEH 0.61 CBAY2 9
H 34 6
11 56 99 0.58 87 PCT 18 P2 VS3
-0.89 TEC TEH 0.61 CBAY2 9
H 34 6
11 56 99 0.82 131 WAR 17 P8 BW1
-1.65 VS3 TEH 0.61 NYAX2 63 H
97 6
SG 11 Summary Data Sheets Page 15 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 56 99 1.74 106 WAR 25 0.2 P4 VS3
-0.81 VS3 TEH 0.61 NYAX2 63 H
97 F
6 11 60 99 0.25 111 PCT 9
P2 BW1
-0.35 TEC TEH 0.61 CBAY2 1
H 71 8
11 66 99 0.31 116 PCT 11 P2 VS3 0.8 TEC TEH 0.61 CBAY2 3
H 22 0
11 86 99 0.25 74 PCT 11 P2 BW1
-0.95 TEC TEH 0.61 CBAY2 27 H
67 0
11 110 99 0.24 123 PCT 11 P2 BW1
-0.85 TEC TEH 0.61 CBAY2 27 H
55 0
11 128 99 0.32 62 PCT 13 P2 VS1 0.84 TEC TEH 0.61 CBAY2 39 H
91 0
11 128 99 0.25 55 PCT 11 P2 VS3
-0.94 TEC TEH 0.61 CBAY2 39 H
91 0
11 142 99 4.04 182 DNT P1 VS5 11.12 TEC TEH 0.61 CBAY2 39 H
84 0
11 168 99 0.24 97 PCT 9
P2 01C 0.17 TEC TEH 0.61 CBAY2 37 H
68 0
11 49 100 0.71 106 PCT 20 P2 BW1
-1.19 TEC TEH 0.61 CBAY2 9
H 60 0
3 11 49 100 0.37 141 PCT 13 P2 BW1 1.03 TEC TEH 0.61 CBAY2 9
H 60 3
11 49 100 1.13 95 WAR 20 0.21 P8 BW1
-0.92 VS3 TEH 0.61 NYAX2 63 H
96 T
3 11 49 100 1.14 94 WAR 20 P23 BW1 0.77 VS3 TEH 0.61 NYAX2 63 H
96 3
11 49 100 TBP TEH TEC 0.61 CBAY2 274 C
14 3
11 49 100 PID P2 BW1
-1.19 TEH TEC 0.61 CBAY2 274 C
14 3
11 51 100 0.31 121 PCT 11 P2 BW1 0.87 TEC TEH 0.61 CBAY2 9
H 42 4
11 57 100 0.25 132 PCT 10 P2 BW1 1.42 TEC TEH 0.61 CBAY2 5
H 62 7
11 169 100 0.65 86 PCT 21 P2 VS5 0.74 TEC TEH 0.61 CBAY2 39 H
129 0
11 169 100 1.48 121 WAR 23 0.29 P25 VS5 0.74 VS3 TEC 0.61 NYAX2 64 C
28 T
0 11 171 100 0.42 74 PCT 16 P2 02C
-0.86 TEC TEH 0.61 CBAY2 39 H
130 0
11 171 100 0.6 110 PCT 22 P2 02C 0.2 TEC TEH 0.61 CBAY2 39 H
130 0
11 171 100 0.42 160 PCT 13 P2 01C 0.1 TEC TEH 0.61 CBAY2 39 H
130 0
11 171 100 1.02 109 WAR 20 0.33 P16 02C
-0.84 11C TEC 0.61 NYAX2 64 C
23 F
0 11 171 100 1.93 117 WAR 26 0.47 P22 02C 0.21 11C TEC 0.61 NYAX2 64 C
23 T
0 11 171 100 0.53 99 WAR 14 P23 01C 0.26 11C TEC 0.61 NYAX2 64 C
23 0
11 58 101 0.42 112 PCT 14 P2 BW1
-0.98 TEC TEH 0.61 CBAY2 5
H 51 7
11 62 101 0.76 115 PCT 23 P2 VS3
-0.88 TEC TEH 0.61 CBAY2 3
H 15 0
11 62 101 2.36 108 WAR 28 0.41 P28 VS3
-0.9 VS3 TEH 0.61 NYAX2 63 H
95 T
0 11 66 101 0.58 112 PCT 17 P2 BW1
-0.79 TEC TEH 0.61 CBAY2 1
H 81 9
0 11 106 101 0.21 119 PCT 9
P2 BW1
-1.45 TEC TEH 0.61 CBAY2 25 H
89 0
11 110 101 0.26 54 PCT 10 P2 BW1
-1.1 TEC TEH 0.61 CBAY2 25 H
87 0
11 118 101 0.37 49 PCT 14 P2 BW2 0.41 TEC TEH 0.61 CBAY2 39 H
141 0
11 144 101 0.23 56 PCT 10 P2 VS4
-0.68 TEC TEH 0.61 CBAY2 39 H
80 0
11 146 101 0.67 126 PCT 21 P2 VS2
-1.13 TEC TEH 0.61 CBAY2 39 H
79 0
11 146 101 1.21 115 WAR 21 0.26 P4 VS2
-1.13 VS3 TEH 0.61 NYAX2 67 H
10 F
0 11 158 101 0.21 49 PCT 10 P2 VS1
-0.74 TEC TEH 0.61 CBAY2 39 H
73 0
11 168 101 0.82 62 PCT 23 P2 01C
-0.89 TEC TEH 0.61 CBAY2 39 H
68 0
11 168 101 2.08 125 WAR 27 0.27 P25 01C
-0.93 01C TEC 0.61 NYAX2 64 C
27 T
0 11 170 101 0.4 70 PCT 15 P2 01C
-0.22 TEC TEH 0.61 CBAY2 39 H
67 0
11 170 101 0.66 88 PCT 21 P2 01C 0.91 TEC TEH 0.61 CBAY2 39 H
67 0
11 170 101 1.51 103 WAR 23 P3 01C
-0.2 01C TEC 0.61 NYAX2 64 C
24 0
11 170 101 1.55 285 WAR 23 P3 01C
-0.09 01C TEC 0.61 NYAX2 64 C
24 0
11 170 101 2.26 102 WAR 28 0.21 P8 01C 0.9 01C TEC 0.61 NYAX2 64 C
24 T
0 11 51 102 0.26 135 PCT 10 P2 BW1 0.84 TEC TEH 0.61 CBAY2 9
H 58 3
11 67 102 0.23 136 PCT 10 P2 VS3
-0.75 TEC TEH 0.61 CBAY2 7
H 61 0
11 115 102 0.25 29 PCT 11 P2 VS1
-0.83 TEC TEH 0.61 CBAY2 39 H
147 0
11 115 102 0.32 98 PCT 13 P2 VS2
-1.03 TEC TEH 0.61 CBAY2 39 H
147 0
11 115 102 0.71 120 PCT 22 P2 VS3 0.79 TEC TEH 0.61 CBAY2 39 H
147 0
11 115 102 1.59 113 PCT 34 P2 VS3 1.05 TEC TEH 0.61 CBAY2 39 H
147 0
11 115 102 1.32 104 PCT 31 P2 VS4
-0.96 TEC TEH 0.61 CBAY2 39 H
147 0
11 115 102 0.21 135 PCT 10 P2 VS4
-0.3 TEC TEH 0.61 CBAY2 39 H
147 0
11 115 102 2.33 106 WAR 28 0.5 P32 VS3 0.67 VS3 TEC 0.61 NYAX2 62 C
20 T
0 SG 11 Summary Data Sheets Page 16 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 115 102 3.19 108 WAR 32 0.38 P32 VS4
-0.82 VS3 TEC 0.61 NYAX2 62 C
20 T
0 11 115 102 TBP TEH TEC 0.61 CBAY2 274 C
20 0
11 115 102 PID P2 VS3 1.05 TEH TEC 0.61 CBAY2 274 C
20 0
11 117 102 0.22 95 PCT 10 P2 VS4 1.58 TEC TEH 0.61 CBAY2 39 H
148 0
11 165 102 0.25 51 PCT 11 P2 VS5 0.79 TEC TEH 0.61 CBAY2 39 H
171 0
11 169 102 1.78 93 PRX P8 11C 24.75 31.83 TEC TEH 0.61 CBAY2 39 H
172 0
11 169 102 NDF 39 11C 26 32 VS3 TEC 0.61 NYAX2 64 C
25 0
11 171 102 0.4 91 PCT 15 P2 01C 0.89 TEC TEH 0.61 CBAY2 39 H
173 0
11 60 103 0.37 73 PCT 15 P2 BW1
-0.54 TEC TEH 0.61 CBAY2 7
H 51 8
11 64 103 0.26 151 PCT 10 P2 VS2
-0.97 TEC TEH 0.61 CBAY2 1
H 83 0
11 88 103 0.3 104 PCT 13 P2 BW1
-0.82 TEC TEH 0.61 CBAY2 27 H
98 0
11 128 103 0.94 107 PCT 26 P2 VS3 0.72 TEC TEH 0.61 CBAY2 39 H
195 0
11 128 103 1.66 112 WAR 24 0.61 P3 VS3 0.72 VS3 TEH 0.61 NYAX2 67 H
7 T
0 11 140 103 0.36 90 PCT 14 P2 VS1
-0.84 TEC TEH 0.61 CBAY2 39 H
189 0
11 140 103 0.3 72 PCT 13 P2 VS4 1.1 TEC TEH 0.61 CBAY2 39 H
189 0
11 142 103 0.24 84 PCT 11 P2 VS2 1.04 TEC TEH 0.61 CBAY2 39 H
188 0
11 142 103 0.52 70 PCT 18 P2 VS4 1.04 TEC TEH 0.61 CBAY2 39 H
188 0
11 146 103 0.31 45 PCT 13 P2 VS1
-0.85 TEC TEH 0.61 CBAY2 39 H
186 0
11 146 103 0.22 109 PCT 10 P2 BW2
-0.82 TEC TEH 0.61 CBAY2 39 H
186 0
11 148 103 0.24 76 PCT 11 P2 BW1 0.82 TEC TEH 0.61 CBAY2 39 H
185 0
11 150 103 0.19 84 PCT 9
P2 10H
-0.03 TEC TEH 0.61 CBAY2 39 H
184 0
11 168 103 0.39 46 PCT 13 P2 01C 0.81 TEC TEH 0.61 CBAY2 39 H
175 0
11 170 103 0.6 66 PCT 19 P2 01C
-0.85 TEC TEH 0.61 CBAY2 39 H
174 0
11 51 104 0.16 27 PCT 8
P2 BW1 0.79 TEC TEH 0.61 CBAY2 11 H
53 4
11 81 104 0.24 45 PCT 11 P2 BW1 0.83 TEC TEH 0.61 CBAY2 27 H
105 0
11 121 104 0.4 105 PCT 15 P2 BW1
-0.85 TEC TEH 0.61 CBAY2 39 H
209 0
11 131 104 0.31 83 PCT 13 P2 BW2
-0.91 TEC TEH 0.61 CBAY2 39 H
214 0
11 169 104 2.46 183 DNT P1 11H
-1.51 TEC TEH 0.61 CBAY2 43 H
7 0
11 169 104 1.43 114 PCT 33 P2 BW2
-0.85 TEC TEH 0.61 CBAY2 43 H
7 0
11 169 104 3.64 120 WAR 34 0.29 P25 BW2
-0.81 VS3 TEC 0.61 NYAX2 64 C
26 F
0 11 169 104 NDF P14 11H
-1.51 11H TEH 0.61 NYAX2 67 H
6 0
11 169 104 PID P2 BW2
-0.85 TEH TEC 0.61 CBAY2 276 C
11 0
11 171 104 0.21 105 PCT 10 P2 01C 0.94 TEC TEH 0.61 CBAY2 43 H
8 0
11 58 105 0.34 118 PCT 11 P2 09H 0.66 TEC TEH 0.61 CBAY2 5
H 39 7
11 126 105 0.27 107 PCT 12 P2 BW1
-0.85 TEC TEH 0.61 CBAY2 43 H
38 0
11 126 105 0.19 86 PCT 10 P2 BW2 0.49 TEC TEH 0.61 CBAY2 43 H
38 0
11 146 105 0.23 141 PCT 11 P2 BW2
-0.85 TEC TEH 0.61 CBAY2 43 H
28 0
11 168 105 0.19 155 PCT 10 P2 BW2 0.87 TEC TEH 0.61 CBAY2 43 H
14 0
11 170 105 0.34 116 PCT 14 P2 BW2 0.87 TEC TEH 0.61 CBAY2 55 H
28 0
11 51 106 0.26 136 PCT 11 P2 BW1
-0.9 TEC TEH 0.61 CBAY2 11 H
65 4
11 51 106 0.28 124 PCT 12 P2 BW2
-0.89 TEC TEH 0.61 CBAY2 11 H
65 4
11 75 106 0.71 102 PCT 22 P2 VS3
-0.93 TEC TEH 0.61 CBAY2 7
H 46 0
11 75 106 1.06 108 WAR 20 0.23 P12 VS3
-0.87 VS3 TEH 0.61 NYAX2 63 H
53 T
0 11 95 106 0.33 106 PCT 12 P2 BW1
-0.63 TEC TEH 0.61 CBAY2 25 H
144 0
11 171 106 0.44 151 PCT 11 P2 01C 0.89 TEC TEH 0.61 CBAY2 43 H
79 0
11 60 107 0.68 128 PCT 19 P2 VS3
-0.76 TEC TEH 0.61 CBAY2 1
H 89 8
11 60 107 2
107 WAR 27 0.41 P28 VS3
-0.86 VS3 TEH 0.61 NYAX2 63 H
94 F
8 11 90 107 0.2 89 PCT 9
P2 BW1
-0.95 TEC TEH 0.61 CBAY2 27 H
130 0
11 96 107 1.03 111 PCT 27 P2 VS4
-0.77 TEC TEH 0.61 CBAY2 27 H
127 0
11 96 107 2.75 105 WAR 30 0.35 P1 VS4
-0.91 VS3 TEC 0.61 NYAX2 62 C
11 T
0 11 134 107 0.25 159 PCT 12 P2 VS1
-0.86 TEC TEH 0.61 CBAY2 43 H
93 0
11 148 107 0.21 149 PCT 10 P2 VS1 0.69 TEC TEH 0.61 CBAY2 43 H
86 0
SG 11 Summary Data Sheets Page 17 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 168 107 0.47 82 PCT 18 P2 BW1
-0.76 TEC TEH 0.61 CBAY2 43 H
10 0
11 51 108 0.37 136 PCT 13 P2 BW2
-0.77 TEC TEH 0.61 CBAY2 9
H 61 4
11 59 108 0.27 144 PCT 10 P2 VS3 0.79 TEC TEH 0.61 CBAY2 1
H 90 8
11 83 108 0.24 107 PCT 11 P2 BW1 0.88 TEC TEH 0.61 CBAY2 27 H
138 0
11 115 108 0.19 107 PCT 10 P2 BW2
-0.17 TEC TEH 0.61 CBAY2 43 H
106 0
11 50 109 0.14 149 PCT 6
P2 VS3 0.84 TEC TEH 0.61 CBAY2 9
H 76 4
11 52 109 0.39 129 PCT 14 P2 VS3 0.9 TEC TEH 0.61 CBAY2 9
H 62 5
11 78 109 0.39 112 PCT 15 P2 BW1
-0.81 TEC TEH 0.61 CBAY2 11 H
4 0
11 128 109 0.37 126 PCT 13 P2 BW2
-0.87 TEC TEH 0.61 CBAY2 49 H
224 0
11 138 109 0.23 100 PCT 10 P2 BW2
-0.72 TEC TEH 0.61 CBAY2 51 H
201 0
11 53 110 0.23 74 PCT 9
P2 BW2
-0.93 TEC TEH 0.61 CBAY2 9
H 63 5
11 57 110 0.33 89 PCT 13 P2 BW1 2.29 TEC TEH 0.61 CBAY2 11 H
59 7
11 59 110 0.45 88 PCT 14 P2 BW1
-0.24 TEC TEH 0.61 CBAY2 1
H 91 8
11 59 110 0.3 147 PCT 11 P2 VS3 0.71 TEC TEH 0.61 CBAY2 1
H 91 8
11 119 110 0.27 116 PCT 10 P2 VS2 0.81 TEC TEH 0.61 CBAY2 53 H
26 0
11 129 110 0.28 113 PCT 12 P2 BW2 0.84 TEC TEH 0.61 CBAY2 51 H
239 0
11 131 110 0.33 77 PCT 13 P2 BW2 0.8 TEC TEH 0.61 CBAY2 51 H
203 0
11 153 110 0.21 121 PCT 10 P2 VS1 0.8 TEC TEH 0.61 CBAY2 51 H
118 0
11 171 110 2.14 178 DNT P1 11H
-1.38 TEC TEH 0.61 CBAY2 51 H
13 0
11 171 110 NDF P17 11H
-1.38 11H TEH 0.61 NYAX2 67 H
5 0
11 50 111 0.22 33 PCT 10 P2 BW1 1.01 TEC TEH 0.61 CBAY2 11 H
66 4
11 56 111 0.28 122 PCT 12 P2 BW2
-1.63 TEC TEH 0.61 CBAY2 11 H
61 7
11 74 111 0.31 54 PCT 13 P2 VS3 0.95 TEC TEH 0.61 CBAY2 7
H 30 0
11 122 111 0.32 86 PCT 13 P2 VS1 0.67 TEC TEH 0.61 CBAY2 51 H
243 0
11 130 111 0.24 116 PCT 10 P2 VS2
-0.83 TEC TEH 0.61 CBAY2 51 H
204 0
11 138 111 0.31 108 PCT 13 P2 VS1 0.75 TEC TEH 0.61 CBAY2 51 H
161 0
11 148 111 0.28 101 PCT 10 P2 VS1
-0.97 TEC TEH 0.61 CBAY2 49 H
137 0
11 152 111 0.21 80 PCT 10 P2 VS1 0.77 TEC TEH 0.61 CBAY2 51 H
117 0
11 156 111 0.26 120 PCT 10 P2 VS1 0.67 TEC TEH 0.61 CBAY2 49 H
94 0
11 164 111 0.36 75 PCT 13 P2 BW1 0.98 TEC TEH 0.61 CBAY2 49 H
49 0
11 164 111 0.25 72 PCT 10 P2 BW2
-0.84 TEC TEH 0.61 CBAY2 49 H
49 0
11 166 111 0.36 137 PCT 13 P2 BW1
-0.92 TEC TEH 0.61 CBAY2 49 H
11 0
11 168 111 0.34 118 PCT 14 P2 BW1
-0.83 TEC TEH 0.61 CBAY2 51 H
9 0
11 168 111 0.35 143 PCT 14 P2 BW1 0.82 TEC TEH 0.61 CBAY2 51 H
9 0
11 49 112 0.23 82 PCT 10 P2 BW1
-1.03 TEC TEH 0.61 CBAY2 11 H
76 4
11 49 112 0.3 89 PCT 12 P2 BW1 0.95 TEC TEH 0.61 CBAY2 11 H
76 4
11 61 112 0.33 53 PCT 14 P2 VS4
-0.93 TEC TEH 0.61 CBAY2 3
H 33 0
11 89 112 0.24 128 PCT 11 P2 BW2 1.13 TEC TEH 0.61 CBAY2 27 H
174 0
11 97 112 0.25 132 PCT 11 P2 BW1
-0.87 TEC TEH 0.61 CBAY2 27 H
178 0
11 103 112 0.42 71 PCT 16 P2 BW1 0.9 TEC TEH 0.61 CBAY2 27 H
181 0
11 129 112 0.22 130 PCT 10 P2 VS1 0.83 TEC TEH 0.61 CBAY2 51 H
205 0
11 151 112 0.34 116 PCT 13 P2 11H 0.21 TEC TEH 0.61 CBAY2 51 H
116 0
11 153 112 0.21 112 PCT 10 P2 VS1
-0.65 TEC TEH 0.61 CBAY2 51 H
79 0
11 157 112 0.26 135 PCT 10 P2 VS2
-0.58 TEC TEH 0.61 CBAY2 49 H
57 0
11 165 112 0.48 124 PCT 15 P2 BW1
-0.84 TEC TEH 0.61 CBAY2 49 H
12 0
11 169 112 0.22 53 PCT 10 P2 BW2
-0.73 TEC TEH 0.61 CBAY2 51 H
15 0
11 58 113 0.51 121 PCT 16 P2 BW1 2.59 TEC TEH 0.61 CBAY2 5
H 15 0
11 166 113 0.23 31 PCT 10 P2 BW2 0.82 TEC TEH 0.61 CBAY2 51 H
7 0
11 168 113 0.4 116 PCT 15 P2 BW2
-0.78 TEC TEH 0.61 CBAY2 51 H
16 0
11 47 114 0.35 125 PCT 13 P2 BW1
-0.08 TEC TEH 0.61 CBAY2 9
H 85 4
11 47 114 0.72 116 PCT 20 P2 BW1 1.03 TEC TEH 0.61 CBAY2 9
H 85 4
11 47 114 0.24 151 PCT 9
P2 BW2
-0.77 TEC TEH 0.61 CBAY2 9
H 85 4
SG 11 Summary Data Sheets Page 18 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 47 114 1.16 92 WAR 21 P25 BW1
-0.11 VS3 TEH 0.61 NYAX2 63 H
93 4
11 47 114 1.7 125 WAR 24 0.17 P23 BW1 0.93 VS3 TEH 0.61 NYAX2 63 H
93 F
4 11 47 114 TBP TEH TEC 0.61 CBAY2 274 C
13 4
11 47 114 PID P2 BW1 1.03 TEH TEC 0.61 CBAY2 274 C
13 4
11 51 114 0.25 135 PCT 10 P2 BW2
-0.78 TEC TEH 0.61 CBAY2 9
H 88 6
11 55 114 0.24 77 PCT 9
P2 BW1
-1.36 TEC TEH 0.61 CBAY2 9
H 72 8
11 55 114 0.48 132 PCT 16 P2 BW1 1.61 TEC TEH 0.61 CBAY2 9
H 72 8
11 57 114 0.32 123 PCT 12 P2 BW1 2.06 TEC TEH 0.61 CBAY2 9
H 67 0
11 71 114 0.23 52 PCT 10 P2 BW1 0.86 TEC TEH 0.61 CBAY2 7
H 24 0
11 131 114 0.47 107 PCT 15 P2 BW2 0.9 TEC TEH 0.61 CBAY2 49 H
187 0
11 167 114 0.67 92 PCT 21 P2 BW2
-0.77 TEC TEH 0.61 CBAY2 51 H
17 0
11 167 114 1.92 113 WAR 26 0.42 P25 BW2
-0.85 VS3 TEC 0.61 NYAX2 62 C
44 T
0 11 46 115 0.75 124 PCT 21 P2 VS3 0.86 TEC TEH 0.61 CBAY2 9
H 103 10 4
11 46 115 0.32 85 PCT 12 P2 BW2 0.92 TEC TEH 0.61 CBAY2 9
H 103 4
11 46 115 1.89 103 WAR 26 0.14 P4 VS3 1.08 VS3 TEH 0.61 NYAX2 63 H
92 F
4 11 46 115 TBP TEH TEC 0.61 CBAY2 274 C
12 4
11 46 115 PID P2 VS3 0.86 TEH TEC 0.61 CBAY2 274 C
12 4
11 48 115 0.19 63 PCT 9
P2 VS3 0.82 TEC TEH 0.61 CBAY2 11 H
81 5
11 48 115 0.41 127 PCT 13 P2 09C
-1.67 TEC TEH 0.61 CBAY2 11 H
81 5
11 54 115 0.29 86 PCT 12 P2 BW1
-1.26 TEC TEH 0.61 CBAY2 11 H
70 8
11 70 115 0.29 90 PCT 12 P2 VS3 0.78 TEC TEH 0.61 CBAY2 7
H 16 0
11 132 115 0.16 56 PCT 8
P2 11H
-1.23 TEC TEH 0.61 CBAY2 51 H
195 0
11 51 116 0.31 87 PCT 11 P2 BW1 0.84 TEC TEH 0.61 CBAY2 9
H 78 7
11 61 116 0.28 85 PCT 10 P2 VS3
-0.86 TEC TEH 0.61 CBAY2 1
H 108 0
11 103 116 0.29 119 PCT 11 P2 BW1
-1.19 TEC TEH 0.61 CBAY2 29 H
9 0
11 105 116 0.36 64 PCT 12 P2 BW1
-1.24 TEC TEH 0.61 CBAY2 29 H
8 0
11 113 116 0.29 88 PCT 10 P2 VS1
-0.86 TEC TEH 0.61 CBAY2 53 H
32 0
11 121 116 0.63 117 PCT 18 P2 VS2 0.77 TEC TEH 0.61 CBAY2 49 H
231 0
11 123 116 0.22 100 PCT 10 P2 VS1 0.83 TEC TEH 0.61 CBAY2 51 H
233 0
11 125 116 0.3 81 PCT 13 P2 VS3 0.96 TEC TEH 0.61 CBAY2 51 H
209 0
11 143 116 0.26 130 PCT 10 P2 VS3
-0.87 TEC TEH 0.61 CBAY2 49 H
132 0
11 165 116 0.3 93 PCT 13 P2 VS5 0.94 TEC TEH 0.61 CBAY2 51 H
19 0
11 48 117 0.4 91 PCT 14 P2 BW1
-0.73 TEC TEH 0.61 CBAY2 9
H 102 6
11 48 117 0.3 151 PCT 11 P2 BW1 0.79 TEC TEH 0.61 CBAY2 9
H 102 6
11 48 117 0.72 120 PCT 20 P2 09C
-0.95 TEC TEH 0.61 CBAY2 9
H 102 6
11 48 117 0.74 117 WAR 16 0.25 P28 09C
-1.14 09C TEC 0.61 NYAX2 62 C
5 T
6 11 48 117 PID P2 09C
-0.95 TEH TEC 0.61 CBAY2 274 C
11 6
11 90 117 0.23 82 PCT 10 P2 10H
-1.56 TEC TEH 0.61 CBAY2 31 H
15 0
11 96 117 0.25 51 PCT 11 P2 VS2
-1.03 TEC TEH 0.61 CBAY2 31 H
17 0
11 98 117 0.25 121 PCT 11 P2 VS3 0.7 TEC TEH 0.61 CBAY2 31 H
18 0
11 108 117 0.23 118 PCT 10 P2 BW2
-1.92 TEC TEH 0.61 CBAY2 31 H
23 0
11 140 117 0.57 109 PCT 19 P2 VS1 0.65 TEC TEH 0.61 CBAY2 51 H
129 0
11 158 117 0.43 94 PCT 14 P2 VS3 0.86 TEC TEH 0.61 CBAY2 49 H
43 0
11 166 117 0.29 72 PCT 10 P2 BW2 0.39 TEC TEH 0.61 CBAY2 45 H
53 0
11 47 118 0.39 78 PCT 13 P2 BW1
-0.94 TEC TEH 0.61 CBAY2 9
H 98 6
11 47 118 0.37 91 PCT 13 P2 BW1 0.88 TEC TEH 0.61 CBAY2 9
H 98 6
11 59 118 0.28 51 PCT 10 P2 BW2 1.07 TEC TEH 0.61 CBAY2 1
H 106 0
11 97 118 0.34 116 PCT 14 P2 BW1
-1.05 TEC TEH 0.61 CBAY2 31 H
33 0
11 103 118 0.22 111 PCT 10 P2 VS2 0.74 TEC TEH 0.61 CBAY2 31 H
30 0
11 111 118 0.26 92 PCT 11 P2 BW1 0.77 TEC TEH 0.61 CBAY2 31 H
26 0
11 141 118 0.29 126 PCT 10 P2 VS1 0.67 TEC TEH 0.61 CBAY2 49 H
130 0
11 143 118 0.26 120 PCT 10 P2 VS1
-0.95 TEC TEH 0.61 CBAY2 49 H
107 0
SG 11 Summary Data Sheets Page 19 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 163 118 0.28 64 PCT 12 P2 VS5 1.23 TEC TEH 0.61 CBAY2 51 H
21 0
11 165 118 0.47 101 PCT 14 P2 VS5 1.02 TEC TEH 0.61 CBAY2 45 H
52 0
11 169 118 0.91 121 PCT 26 P2 BW2
-0.71 TEC TEH 0.61 CBAY2 47 H
26 0
11 169 118 2.38 116 WAR 28 0.32 P25 BW2
-0.87 VS3 TEC 0.61 NYAX2 62 C
43 F
0 11 169 118 2.07 148 WAR 27 1.36 P26 BW2 0.3 VS3 TEC 0.61 NYAX2 62 C
43 T
0 11 44 119 0.66 97 PCT 22 P2 BW1 1.08 TEC TEH 0.61 CBAY2 15 H
62 5
11 44 119 2.15 97 WAR 27 0.23 P24 BW1 0.81 VS3 TEH 0.61 NYAX2 63 H
91 F
5 11 44 119 PID P2 BW1 1.08 TEH TEC 0.61 CBAY2 274 C
10 5
11 46 119 0.4 103 PCT 16 P2 BW1 0.88 TEC TEH 0.61 CBAY2 15 H
20 6
11 74 119 0.58 122 PCT 20 P2 VS3 0.75 TEC TEH 0.61 CBAY2 7
H 6
0 11 74 119 1.47 102 WAR 23 0.35 P13 VS3 0.61 VS3 TEH 0.61 NYAX2 61 H
13 T
0 11 78 119 0.25 83 PCT 11 P2 BW1
-0.86 TEC TEH 0.61 CBAY2 7
H 8
0 11 86 119 0.29 141 PCT 11 P2 VS3 0.66 TEC TEH 0.61 CBAY2 29 H
14 0
11 90 119 0.19 89 PCT 8
P2 10H
-1.15 TEC TEH 0.61 CBAY2 29 H
16 0
11 132 119 0.12 72 PCT 5
P2 11H
-0.27 TEC TEH 0.61 CBAY2 49 H
171 0
11 132 119 0.31 51 PCT 11 P2 BW1
-0.94 TEC TEH 0.61 CBAY2 49 H
171 0
11 162 119 0.22 102 PCT 10 P2 BW2
-0.81 TEC TEH 0.61 CBAY2 51 H
22 0
11 45 120 0.74 106 PCT 23 P2 BW1
-0.94 TEC TEH 0.61 CBAY2 15 H
54 6
11 45 120 0.55 98 PCT 19 P2 BW1 0.87 TEC TEH 0.61 CBAY2 15 H
54 11 6
11 45 120 1.26 107 WAR 21 0.17 P8 BW1
-0.77 VS3 TEH 0.61 NYAX2 63 H
30 F
6 11 45 120 1.03 150 WAR 20 P44 BW1 0.65 VS3 TEH 0.61 NYAX2 63 H
30 6
11 45 120 PID P2 BW1
-0.94 TEH TEC 0.61 CBAY2 274 C
9 6
11 47 120 0.28 117 PCT 12 P2 BW1
-0.94 TEC TEH 0.61 CBAY2 15 H
21 7
11 47 120 0.21 51 PCT 10 P2 VS3 0.84 TEC TEH 0.61 CBAY2 15 H
21 7
11 73 120 0.24 28 PCT 11 P2 BW1 0.94 TEC TEH 0.61 CBAY2 15 H
25 0
11 77 120 0.3 67 PCT 11 P2 BW2 1.26 TEC TEH 0.61 CBAY2 29 H
43 0
11 105 120 0.27 88 PCT 10 P2 BW1
-1 TEC TEH 0.61 CBAY2 29 H
29 0
11 111 120 0.25 90 PCT 11 P2 VS2
-0.87 TEC TEH 0.61 CBAY2 55 H
7 0
11 115 120 0.32 54 PCT 11 P2 BW2
-1.28 TEC TEH 0.61 CBAY2 53 H
13 0
11 151 120 0.39 87 PCT 15 P2 VS1
-0.86 TEC TEH 0.61 CBAY2 51 H
62 0
11 165 120 0.21 142 PCT 10 P2 BW2 0.65 TEC TEH 0.61 CBAY2 47 H
34 0
11 42 121 0.38 102 PCT 15 P2 BW1 1.12 TEC TEH 0.61 CBAY2 15 H
61 9
5 11 42 121 0.2 41 PCT 10 P2 VS3 0.7 TEC TEH 0.61 CBAY2 15 H
61 5
11 42 121 0.29 93 PCT 13 P2 BW2
-0.88 TEC TEH 0.61 CBAY2 15 H
61 5
11 44 121 0.34 101 PCT 12 P2 BW2 0.84 TEC TEH 0.61 CBAY2 13 H
20 6
11 48 121 0.67 112 PCT 18 P2 09C
-1.21 TEC TEH 0.61 CBAY2 13 H
18 8
11 126 121 0.27 55 PCT 12 P2 BW2
-0.87 TEC TEH 0.61 CBAY2 51 H
189 0
11 146 121 0.33 135 PCT 12 P2 VS1
-0.78 TEC TEH 0.61 CBAY2 49 H
84 0
11 162 121 0.41 101 PCT 13 P2 BW2
-0.77 TEC TEH 0.61 CBAY2 45 H
49 0
11 45 122 0.44 128 PCT 14 P2 BW1
-0.86 TEC TEH 0.61 CBAY2 13 H
21 7
11 45 122 0.39 99 PCT 13 P2 BW1 0.84 TEC TEH 0.61 CBAY2 13 H
21 7
11 47 122 0.49 129 PCT 15 P2 BW1 0.82 TEC TEH 0.61 CBAY2 13 H
22 8
11 61 122 0.37 100 PCT 12 P2 VS2
-0.81 TEC TEH 0.61 CBAY2 1
H 120 0
11 69 122 3.74 183 DNT P1 VS4 1.01 TEC TEH 0.61 CBAY2 13 H
29 0
11 69 122 NDF P12 VS4 1.01 VS3 TEC 0.61 NYAX2 62 C
7 0
11 81 122 0.27 103 PCT 12 P2 BW1 0.84 TEC TEH 0.61 CBAY2 31 H
76 0
11 119 122 0.24 128 PCT 11 P2 VS2 0.64 TEC TEH 0.61 CBAY2 51 H
215 0
11 131 122 0.48 117 PCT 15 P2 BW2 1
TEC TEH 0.61 CBAY2 49 H
153 13 0
11 151 122 0.23 122 PCT 10 P2 VS1 0.72 TEC TEH 0.61 CBAY2 51 H
37 0
11 165 122 0.93 114 PCT 26 P2 BW2 0.78 TEC TEH 0.61 CBAY2 47 H
22 0
11 165 122 2.4 96 WAR 28 0.46 P11 BW2 0.76 VS3 TEC 0.61 NYAX2 62 C
42 T
0 11 167 122 0.52 87 PCT 15 P2 BW2 0.88 TEC TEH 0.61 CBAY2 45 H
29 0
SG 11 Summary Data Sheets Page 20 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 36 123 0.39 107 PCT 13 P2 BW1
-0.91 TEC TEH 0.61 CBAY2 17 H
5 4
11 36 123 0.72 10 PCT 20 P2 BW1 0.95 TEC TEH 0.61 CBAY2 17 H
5 4
11 36 123 0.87 145 WAR 18 P10 BW1
-0.78 VS3 TEH 0.61 NYAX2 63 H
20 4
11 36 123 1.36 85 WAR 22 0.17 P23 BW1 0.93 VS3 TEH 0.61 NYAX2 63 H
20 F
4 11 36 123 TBP TEH TEC 0.61 CBAY2 274 C
5 4
11 36 123 PID P2 BW1 0.95 TEH TEC 0.61 CBAY2 274 C
5 4
11 38 123 0.33 91 PCT 11 P2 BW1
-1.09 TEC TEH 0.61 CBAY2 13 H
62 5
11 40 123 0.3 44 PCT 13 P2 BW1 0.9 TEC TEH 0.61 CBAY2 15 H
63 6
11 42 123 0.88 115 PCT 25 P2 BW1 1.06 TEC TEH 0.61 CBAY2 15 H
55 7
11 42 123 0.28 148 PCT 12 P2 BW2
-0.96 TEC TEH 0.61 CBAY2 15 H
55 7
11 42 123 0.4 73 PCT 16 P2 BW2 0.85 TEC TEH 0.61 CBAY2 15 H
55 7
11 42 123 2.32 89 WAR 28 0.84 P23 BW1 1.03 VS3 TEH 0.61 NYAX2 63 H
28 T
7 11 42 123 TBP TEH TEC 0.61 CBAY2 274 C
7 7
11 42 123 PID P2 BW1 1.06 TEH TEC 0.61 CBAY2 274 C
7 7
11 44 123 0.47 115 PCT 17 P2 BW1
-1.09 TEC TEH 0.61 CBAY2 15 H
64 8
11 44 123 0.25 119 PCT 11 P2 BW1 0.93 TEC TEH 0.61 CBAY2 15 H
64 7
8 11 46 123 0.25 40 PCT 11 P2 BW1 1
TEC TEH 0.61 CBAY2 15 H
38 0
11 48 123 0.93 106 PCT 25 P2 09C
-1.67 TEC TEH 0.61 CBAY2 15 H
37 0
11 48 123 1.45 106 WAR 23 0.29 P27 09C
-1.23 09C TEC 0.61 NYAX2 62 C
6 T
0 11 58 123 0.28 65 PCT 12 P2 BW1
-0.94 TEC TEH 0.61 CBAY2 15 H
32 0
11 108 123 0.32 79 PCT 11 P2 BW2
-1.73 TEC TEH 0.61 CBAY2 29 H
59 0
11 152 123 0.25 135 PCT 10 P2 VS1 0.78 TEC TEH 0.61 CBAY2 49 H
37 0
11 162 123 0.36 104 PCT 11 P2 VS5 1.09 TEC TEH 0.61 CBAY2 45 H
40 0
11 166 123 0.31 100 PCT 10 P2 BW1
-0.57 TEC TEH 0.61 CBAY2 45 H
32 0
11 166 123 0.61 60 PCT 17 P2 BW2 0.39 TEC TEH 0.61 CBAY2 45 H
32 0
11 168 123 0.26 120 PCT 12 P2 BW1
-1 TEC TEH 0.61 CBAY2 55 H
30 0
11 33 124 0.35 99 PCT 12 P2 BW1
-0.92 TEC TEH 0.61 CBAY2 13 H
66 3
11 37 124 0.27 54 PCT 10 P2 BW2 0.96 TEC TEH 0.61 CBAY2 13 H
63 5
11 39 124 0.59 87 PCT 20 P2 BW1
-1 TEC TEH 0.61 CBAY2 15 H
75 6
11 39 124 0.69 114 WAR 16 0.17 P9 BW1
-0.65 VS3 TEH 0.61 NYAX2 63 H
23 F
6 11 39 124 PID P2 BW1
-1 TEH TEC 0.61 CBAY2 274 C
6 6
11 41 124 0.24 103 PCT 11 P2 BW1
-0.97 TEC TEH 0.61 CBAY2 15 H
56 7
11 41 124 0.4 87 PCT 16 P2 VS3 0.88 TEC TEH 0.61 CBAY2 15 H
56 7
11 43 124 0.21 137 PCT 10 P2 BW1
-0.66 TEC TEH 0.61 CBAY2 15 H
39 8
11 45 124 1.26 104 PCT 30 P2 BW1 0.85 TEC TEH 0.61 CBAY2 15 H
40 0
11 45 124 3.31 94 WAR 32 0.38 P23 BW1 0.84 VS3 TEH 0.61 NYAX2 63 H
29 T
0 11 45 124 PID P2 BW1 0.85 TEH TEC 0.61 CBAY2 274 C
8 0
11 49 124 0.35 59 PCT 14 P2 BW1 0.98 TEC TEH 0.61 CBAY2 15 H
42 0
11 95 124 0.31 121 PCT 11 P2 BW2 0.86 TEC TEH 0.61 CBAY2 29 H
68 0
11 103 124 0.3 53 PCT 11 P2 BW2
-0.94 TEC TEH 0.61 CBAY2 29 H
64 0
11 113 124 0.31 120 PCT 11 P2 VS2 0.93 TEC TEH 0.61 CBAY2 53 H
8 0
11 161 124 0.32 149 PCT 10 P2 BW2
-0.72 TEC TEH 0.61 CBAY2 45 H
39 0
11 165 124 1.28 110 PCT 27 P2 BW2
-0.71 TEC TEH 0.61 CBAY2 45 H
33 0
11 165 124 2.16 114 WAR 27 0.42 P25 BW2
-0.9 VS3 TEC 0.61 NYAX2 62 C
41 T
0 11 167 124 0.55 104 PCT 19 P2 BW2
-0.82 TEC TEH 0.61 CBAY2 55 H
29 0
11 48 125 0.28 136 PCT 10 P2 BW1 0.84 TEC TEH 0.61 CBAY2 13 H
39 0
11 84 125 0.3 88 PCT 13 P2 VS2 0.72 TEC TEH 0.61 CBAY2 31 H
81 0
11 116 125 0.24 97 PCT 10 P2 BW1
-1.2 TEC TEH 0.61 CBAY2 51 H
218 0
11 128 125 0.54 126 PCT 17 P2 BW2
-0.8 TEC TEH 0.61 CBAY2 49 H
156 0
11 164 125 2.63 121 PCT 42 P2 BW2 0.79 TEC TEH 0.61 CBAY2 47 H
13 0
11 164 125 4.62 103 WAR 37 0.23 P10 BW2 0.77 VS3 TEC 0.61 NYAX2 62 C
39 F
0 11 164 125 TBP TEH TEC 0.61 CBAY2 274 C
26 0
SG 11 Summary Data Sheets Page 21 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 164 125 PID P2 BW2 0.79 TEH TEC 0.61 CBAY2 274 C
26 0
11 164 125 2.86 121 PCT 31 P49 BW2 0.79 TEH TEC 0.61 CBAY2 278 C
9 0
11 166 125 1.79 113 PCT 32 P2 BW2
-0.79 TEC TEH 0.61 CBAY2 45 H
16 0
11 166 125 3.39 100 WAR 33 0.2 P25 BW2
-0.87 VS3 TEC 0.61 NYAX2 62 C
40 F
0 11 166 125 PID P2 BW2
-0.79 TEH TEC 0.61 CBAY2 276 C
19 0
11 51 126 0.25 112 PCT 9
P2 09H 0.82 TEC TEH 0.61 CBAY2 13 H
47 0
11 55 126 0.31 101 PCT 11 P2 VS3
-0.84 TEC TEH 0.61 CBAY2 1
H 134 0
11 75 126 0.23 63 PCT 9
P2 BW1 0.84 TEC TEH 0.61 CBAY2 13 H
52 0
11 79 126 0.38 84 PCT 15 P2 BW1 0.81 TEC TEH 0.61 CBAY2 31 H
112 0
11 111 126 0.31 118 PCT 13 P2 BW2 1.07 TEC TEH 0.61 CBAY2 31 H
96 0
11 129 126 0.33 129 PCT 14 P2 VS3
-0.93 TEC TEH 0.61 CBAY2 51 H
141 0
11 131 126 0.41 101 PCT 16 P2 BW2 0.79 TEC TEH 0.61 CBAY2 51 H
138 0
11 145 126 0.23 108 PCT 10 P2 VS1
-0.87 TEC TEH 0.61 CBAY2 51 H
56 0
11 145 126 0.77 122 PCT 23 P2 VS3
-0.8 TEC TEH 0.61 CBAY2 51 H
56 0
11 145 126 0.61 134 WAR 15 P4 VS1
-0.7 VS3 TEH 0.61 NYAX2 63 H
31 0
11 145 126 1.67 107 WAR 24 0.56 P4 VS3
-0.57 VS3 TEH 0.61 NYAX2 63 H
31 T
0 11 149 126 0.31 105 PCT 13 P2 VS1 0.8 TEC TEH 0.61 CBAY2 51 H
51 0
11 155 126 0.2 99 PCT 10 P2 BW2
-0.75 TEC TEH 0.61 CBAY2 47 H
43 0
11 163 126 0.29 131 PCT 13 P2 BW2 0.77 TEC TEH 0.61 CBAY2 47 H
12 0
11 165 126 1.65 108 PCT 31 P2 BW2
-0.82 TEC TEH 0.61 CBAY2 45 H
15 0
11 165 126 2.68 86 WAR 30 0.41 P24 BW2
-0.9 VS3 TEC 0.61 NYAX2 62 C
38 T
0 11 165 126 PID P2 BW2
-0.82 TEH TEC 0.61 CBAY2 276 C
14 0
11 26 127 0.28 88 PCT 12 P2 BW1 0.97 TEC TEH 0.61 CBAY2 21 H
14 3
11 28 127 0.29 94 PCT 10 P2 BW1 0.96 TEC TEH 0.61 CBAY2 17 H
22 4
11 86 127 0.35 95 PCT 12 P2 VS2 0.75 TEC TEH 0.61 CBAY2 29 H
81 0
11 88 127 0.49 76 PCT 16 P2 BW1
-0.94 TEC TEH 0.61 CBAY2 29 H
82 0
11 106 127 0.31 83 PCT 11 P2 BW2 1.49 TEC TEH 0.61 CBAY2 29 H
91 0
11 108 127 0.3 109 PCT 11 P2 BW2 1.97 TEC TEH 0.61 CBAY2 29 H
92 0
11 110 127 0.34 144 PCT 12 P2 BW1
-1.18 TEC TEH 0.61 CBAY2 29 H
93 0
11 114 127 0.23 100 PCT 10 P2 BW2 0.41 TEC TEH 0.61 CBAY2 51 H
220 0
11 124 127 0.65 103 PCT 19 P2 BW2
-0.83 TEC TEH 0.61 CBAY2 49 H
163 0
11 146 127 0.19 64 PCT 9
P2 VS1 0.72 TEC TEH 0.61 CBAY2 51 H
42 0
11 152 127 0.37 125 PCT 15 P2 BW2
-0.81 TEC TEH 0.61 CBAY2 47 H
52 0
11 156 127 0.49 115 PCT 14 P2 BW2
-0.78 TEC TEH 0.61 CBAY2 45 H
43 0
11 158 127 0.52 105 PCT 15 P2 BW2
-0.77 TEC TEH 0.61 CBAY2 45 H
36 0
11 158 127 0.41 82 PCT 13 P2 BW2 0.8 TEC TEH 0.61 CBAY2 45 H
36 0
11 160 127 1.65 101 PCT 35 P2 BW2
-0.75 TEC TEH 0.61 CBAY2 47 H
16 0
11 160 127 2.93 102 WAR 31 0.22 P25 BW2
-0.9 VS3 TEC 0.61 NYAX2 62 C
36 F
0 11 160 127 TBP TEH TEC 0.61 CBAY2 274 C
22 0
11 160 127 PID P2 BW2
-0.75 TEH TEC 0.61 CBAY2 274 C
22 0
11 162 127 1.37 108 PCT 32 P2 BW2
-0.81 TEC TEH 0.61 CBAY2 47 H
11 0
11 162 127 2.84 102 WAR 30 0.21 P25 BW2
-0.84 VS3 TEC 0.61 NYAX2 62 C
37 F
0 11 162 127 PID P2 BW2
-0.81 TEH TEC 0.61 CBAY2 274 C
23 0
11 164 127 0.25 69 PCT 9
P2 BW2
-0.76 TEC TEH 0.61 CBAY2 45 H
14 0
11 31 128 0.26 125 PCT 9
P2 BW1 0.88 TEC TEH 0.61 CBAY2 17 H
9 8
11 33 128 0.25 96 PCT 11 P2 BW1
-1.11 TEC TEH 0.61 CBAY2 19 H
12 0
11 39 128 0.58 66 PCT 20 P2 BW1 1.05 TEC TEH 0.61 CBAY2 15 H
67 0
11 39 128 1.79 128 WAR 25 0.29 P8 BW1 0.9 VS3 TEH 0.61 NYAX2 63 H
16 T
0 11 45 128 0.37 94 PCT 13 P2 BW1
-0.87 TEC TEH 0.61 CBAY2 17 H
34 0
11 49 128 0.3 125 PCT 11 P2 08H 0.76 TEC TEH 0.61 CBAY2 19 H
20 0
11 89 128 0.28 141 PCT 10 P2 BW1 0.97 TEC TEH 0.61 CBAY2 29 H
104 0
11 119 128 0.26 133 PCT 11 P2 BW2 0.36 TEC TEH 0.61 CBAY2 51 H
182 0
SG 11 Summary Data Sheets Page 22 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 123 128 0.29 99 PCT 11 P2 BW2 0.52 TEC TEH 0.61 CBAY2 49 H
162 0
11 125 128 0.28 45 PCT 10 P2 BW2 0.39 TEC TEH 0.61 CBAY2 49 H
159 0
11 127 128 0.37 143 PCT 13 P2 BW2 0.88 TEH TEC 0.61 CBAY2 246 C
40 0
11 131 128 0.3 123 PCT 11 P2 BW2 0.9 TEC TEH 0.61 CBAY2 49 H
120 0
11 141 128 0.37 50 PCT 13 P2 BW2 0.9 TEC TEH 0.61 CBAY2 49 H
75 0
11 147 128 0.23 121 PCT 10 P2 VS1 0.7 TEC TEH 0.61 CBAY2 51 H
49 0
11 147 128 0.27 113 PCT 12 P2 BW2 0.82 TEC TEH 0.61 CBAY2 51 H
49 0
11 149 128 0.29 120 PCT 11 P2 VS1 0.83 TEC TEH 0.61 CBAY2 49 H
28 0
11 151 128 0.24 123 PCT 11 P2 BW2 0.77 TEC TEH 0.61 CBAY2 47 H
51 0
11 159 128 0.28 113 PCT 12 P2 BW2 0.82 TEC TEH 0.61 CBAY2 47 H
15 0
11 163 128 2.11 110 PCT 35 P2 BW2 0.84 TEC TEH 0.61 CBAY2 45 H
13 0
11 163 128 4.03 102 WAR 36 0.4 P10 BW2 1.07 VS3 TEC 0.61 NYAX2 62 C
35 T
0 11 163 128 TBP TEH TEC 0.61 CBAY2 274 C
24 0
11 163 128 PID P2 BW2 0.84 TEH TEC 0.61 CBAY2 274 C
24 0
11 165 128 0.59 129 PCT 16 P2 BW1
-0.92 TEC TEH 0.61 CBAY2 45 H
10 0
11 165 128 0.78 110 PCT 20 P2 BW2
-0.8 TEC TEH 0.61 CBAY2 45 H
10 0
11 165 128 0.45 126 PCT 14 P2 BW2 0.83 TEC TEH 0.61 CBAY2 45 H
10 0
11 165 128 1.47 275 WAR 23 0.38 P24 BW2
-0.87 VS3 TEC 0.61 NYAX2 62 C
34 T
0 11 165 128 0.69 313 WAR 16 P10 BW2 1.02 VS3 TEC 0.61 NYAX2 62 C
34 0
11 90 129 0.26 53 PCT 11 P2 10H
-1.05 TEC TEH 0.61 CBAY2 31 H
120 0
11 120 129 0.22 88 PCT 10 P2 VS1 0.87 TEC TEH 0.61 CBAY2 51 H
179 0
11 128 129 0.26 92 PCT 10 P2 BW1
-0.7 TEH TEC 0.61 CBAY2 246 C
38 0
11 132 129 0.31 118 PCT 11 P2 VS1 0.77 TEC TEH 0.61 CBAY2 49 H
118 0
11 152 129 0.46 64 PCT 18 P2 BW2
-0.71 TEC TEH 0.61 CBAY2 47 H
40 0
11 154 129 0.3 56 PCT 10 P2 BW2
-0.77 TEC TEH 0.61 CBAY2 45 H
41 0
11 156 129 0.3 95 PCT 10 P2 BW2 0.78 TEC TEH 0.61 CBAY2 45 H
34 0
11 160 129 0.79 136 PCT 24 P2 BW2 0.77 TEC TEH 0.61 CBAY2 47 H
5 0
11 160 129 1.65 85 WAR 24 0.29 P10 BW2 0.75 VS3 TEC 0.61 NYAX2 62 C
32 T
0 11 162 129 1.09 116 PCT 24 P2 BW2 0.84 TEC TEH 0.61 CBAY2 45 H
12 0
11 162 129 2.22 97 WAR 27 0.34 P10 BW2 0.73 VS3 TEC 0.61 NYAX2 62 C
33 T
0 11 13 130 0.42 111 PCT 16 P2 BW1 0.99 TEC TEH 0.61 CBAY2 23 H
7 0
11 15 130 0.27 46 PCT 12 P2 BW1
-0.9 TEC TEH 0.61 CBAY2 23 H
8 0
11 41 130 0.34 129 PCT 12 P2 VS3 0.74 TEC TEH 0.61 CBAY2 17 H
28 0
11 61 130 0.25 65 PCT 11 P2 BW1 0.76 TEC TEH 0.61 CBAY2 21 H
30 0
11 81 130 0.26 97 PCT 10 P2 VS2
-0.73 TEH TEC 0.61 CBAY2 208 C
24 0
11 87 130 0.28 32 PCT 11 P2 BW1 0.82 TEH TEC 0.61 CBAY2 208 C
21 0
11 111 130 0.4 89 PCT 14 P2 BW1 0.89 TEH TEC 0.61 CBAY2 208 C
7 0
11 129 130 0.46 135 PCT 12 P2 VS2
-0.8 TEH TEC 0.61 CBAY2 244 C
41 0
11 129 130 0.54 112 PCT 14 P2 VS2 0.79 TEH TEC 0.61 CBAY2 244 C
41 0
11 159 130 2.13 92 WAR 27 0.34 P9 BW2 0.89 VS3 TEC 0.61 NYAX2 62 C
31 T
0 11 159 130 0.97 135 PCT 23 P2 BW2 0.82 TEH TEC 0.61 CBAY2 246 C
53 0
11 161 130 2.18 96 WAR 27 0.53 P9 BW2 0.67 VS3 TEC 0.61 NYAX2 62 C
30 T
0 11 161 130 1.07 125 PCT 25 P2 BW2 0.8 TEH TEC 0.61 CBAY2 246 C
54 0
11 163 130 2.4 96 WAR 28 0.38 P9 BW2 0.93 VS3 TEC 0.61 NYAX2 62 C
29 T
0 11 163 130 1.2 131 PCT 26 P2 BW2 0.85 TEH TEC 0.61 CBAY2 246 C
55 0
11 165 130 0.87 122 WAR 18 P23 BW2
-0.96 VS3 TEC 0.61 NYAX2 62 C
28 0
11 165 130 1.7 93 WAR 24 0.2 P9 BW2 0.83 VS3 TEC 0.61 NYAX2 62 C
28 F
0 11 165 130 0.28 123 PCT 10 P2 BW2
-0.83 TEH TEC 0.61 CBAY2 246 C
56 0
11 165 130 1.07 123 PCT 25 P2 BW2 0.9 TEH TEC 0.61 CBAY2 246 C
56 0
11 18 131 0.38 113 PCT 14 P2 08H 0.43 TEC TEH 0.61 CBAY2 21 H
7 0
11 88 131 0.31 118 PCT 12 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 212 C
93 0
11 90 131 0.14 127 PCT 6
P2 10H
-0.99 TEH TEC 0.61 CBAY2 212 C
94 0
SG 11 Summary Data Sheets Page 23 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 90 131 0.27 84 PCT 10 P2 BW1
-0.7 TEH TEC 0.61 CBAY2 212 C
94 0
11 120 131 0.27 117 PCT 8
P2 VS2 1.04 TEH TEC 0.61 CBAY2 210 C
90 0
11 152 131 0.34 146 PCT 12 P2 BW2
-0.8 TEH TEC 0.61 CBAY2 246 C
63 0
11 156 131 2.07 117 WAR 27 0.2 P7 BW2
-0.92 VS3 TEC 0.61 NYAX2 62 C
24 F
0 11 156 131 0.84 131 PCT 21 P2 BW2
-0.8 TEH TEC 0.61 CBAY2 246 C
61 0
11 158 131 2.03 145 WAR 27 0.59 P8 BW2 0.71 VS3 TEC 0.61 NYAX2 62 C
25 T
0 11 158 131 0.8 134 PCT 21 P2 BW2 0.79 TEH TEC 0.61 CBAY2 246 C
60 0
11 162 131 2.65 96 WAR 29 0.29 P9 BW2 0.73 VS3 TEC 0.61 NYAX2 62 C
26 T
0 11 162 131 1.46 100 PCT 29 P2 BW2 0.77 TEH TEC 0.61 CBAY2 246 C
58 0
11 164 131 3.51 95 WAR 33 0.23 P9 BW2 0.68 VS3 TEC 0.61 NYAX2 62 C
27 F
0 11 164 131 1.75 117 PCT 32 P2 BW2 0.87 TEH TEC 0.61 CBAY2 246 C
57 0
11 164 131 PID P2 BW2 0.87 TEH TEC 0.61 CBAY2 274 C
25 0
11 15 132 3.07 307 PLP 8
FDP 1.38 TEC TEH 0.61 CBAY2 53 H
180 SR 0
11 15 132 NDF 71 FDP 1.38 01C TEC 0.61 NYAX2 60 C
7 0
11 19 132 0.29 77 PCT 10 P2 BW1
-0.83 TEC TEH 0.61 CBAY2 53 H
179 0
11 33 132 0.28 121 PCT 12 P2 VS3 0.77 TEC TEH 0.61 CBAY2 55 H
129 0
11 35 132 0.41 109 PCT 16 P2 VS3 0.6 TEC TEH 0.61 CBAY2 55 H
128 0
11 41 132 0.5 90 PCT 15 P2 BW2
-0.87 TEC TEH 0.61 CBAY2 53 H
72 0
11 87 132 0.32 102 PCT 10 P2 BW1 0.98 TEH TEC 0.61 CBAY2 210 C
100 0
11 97 132 0.5 113 PCT 13 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 210 C
95 0
11 131 132 0.23 119 PCT 9
P2 BW2 0.74 TEH TEC 0.61 CBAY2 246 C
27 0
11 143 132 0.41 89 PCT 11 P2 BW1 0.89 TEH TEC 0.61 CBAY2 244 C
48 0
11 143 132 0.76 139 PCT 18 P2 VS4
-0.77 TEH TEC 0.61 CBAY2 244 C
48 0
11 163 132 0.44 59 PCT 12 P2 BW2 0.82 TEH TEC 0.61 CBAY2 244 C
58 0
11 68 133 0.19 49 PCT 9
P2 BW1
-0.83 TEC TEH 0.61 CBAY2 55 H
39 0
11 68 133 3.43 182 DNT P1 VS4 0.61 TEC TEH 0.61 CBAY2 55 H
39 0
11 68 133 NDF P12 VS4 0.61 VS3 TEC 0.61 NYAX2 62 C
8 0
11 94 133 0.32 120 PCT 10 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 210 C
111 0
11 98 133 0.35 118 PCT 10 P2 BW1 1
TEH TEC 0.61 CBAY2 206 C
30 0
11 118 133 0.51 138 PCT 13 P2 BW1
-1.21 TEH TEC 0.61 CBAY2 206 C
20 0
11 126 133 0.26 107 PCT 8
P2 VS2 1.17 TEH TEC 0.61 CBAY2 244 C
44 0
11 136 133 0.15 147 PCT 5
P2 VS1 1.21 TEH TEC 0.61 CBAY2 240 C
92 0
11 154 133 0.39 154 PCT 11 P2 BW2
-0.9 TEH TEC 0.61 CBAY2 244 C
63 0
11 31 134 0.23 83 PCT 11 P2 BW1
-0.89 TEC TEH 0.61 CBAY2 55 H
131 0
11 31 134 0.82 86 MBM 6
08C 9.31 TEC TEH 0.61 CBAY2 55 H
131 0
11 57 134 0.41 115 PCT 16 P2 VS3 0.87 TEC TEH 0.61 CBAY2 55 H
57 0
11 103 134 0.43 87 PCT 15 P2 BW1 0.88 TEH TEC 0.61 CBAY2 208 C
48 0
11 111 134 0.4 93 PCT 14 P2 VS2
-0.79 TEH TEC 0.61 CBAY2 208 C
44 0
11 115 134 0.24 111 PCT 10 P2 VS3 0.92 TEH TEC 0.61 CBAY2 208 C
42 0
11 119 134 0.26 49 PCT 10 P2 BW1 0.98 TEH TEC 0.61 CBAY2 208 C
40 0
11 123 134 0.38 126 PCT 13 P2 VS1 0.59 TEH TEC 0.61 CBAY2 246 C
33 0
11 90 135 0.32 79 PCT 12 P2 10H
-1.84 TEH TEC 0.61 CBAY2 208 C
67 0
11 98 135 0.25 140 PCT 10 P2 BW1
-0.79 TEH TEC 0.61 CBAY2 208 C
71 0
11 102 135 0.26 63 PCT 10 P2 VS2 0.8 TEH TEC 0.61 CBAY2 208 C
73 0
11 104 135 0.51 87 PCT 16 P2 VS2 0.82 TEH TEC 0.61 CBAY2 208 C
74 0
11 126 135 0.39 140 PCT 11 P2 BW1
-0.67 TEH TEC 0.61 CBAY2 244 C
35 0
11 144 135 0.28 131 PCT 10 P2 VS2 1.17 TEH TEC 0.61 CBAY2 246 C
90 0
11 111 136 0.28 139 PCT 8
P2 BW2
-0.9 TEH TEC 0.61 CBAY2 206 C
38 0
11 129 136 0.4 126 PCT 13 P2 VS2 0.79 TEH TEC 0.61 CBAY2 246 C
11 0
11 139 136 0.45 125 PCT 12 P2 VS1
-0.89 TEH TEC 0.61 CBAY2 240 C
47 0
11 12 137 0.19 91 PCT 7
P2 05H 0.03 TEC TEH 0.61 CBAY2 53 H
201 0
11 30 137 0.16 93 DSI P6 FDP
-0.3 TEC TEH 0.61 CBAY2 53 H
210 0
SG 11 Summary Data Sheets Page 24 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 30 137 NDF P21 FDP
-0.3 01C TEC 0.61 NYAX2 58 C
14 0
11 52 137 0.22 28 PCT 10 P2 BW1
-0.87 TEC TEH 0.61 CBAY2 55 H
81 0
11 62 137 0.15 142 PCT 8
P2 VS3
-0.91 TEC TEH 0.61 CBAY2 55 H
76 0
11 68 137 0.22 65 PCT 10 P2 BW1
-0.85 TEC TEH 0.61 CBAY2 55 H
73 0
11 90 137 0.31 110 PCT 9
P2 10H
-1.18 TEH TEC 0.61 CBAY2 206 C
59 0
11 122 137 0.48 141 PCT 13 P2 VS1 0.95 TEH TEC 0.61 CBAY2 206 C
77 0
11 130 137 0.38 122 PCT 11 P2 VS1 0.76 TEH TEC 0.61 CBAY2 244 C
23 0
11 154 137 0.66 122 PCT 16 P2 BW2
-0.88 TEH TEC 0.61 CBAY2 244 C
83 0
11 41 138 0.32 105 PCT 11 P2 BW2 0.95 TEC TEH 0.61 CBAY2 53 H
157 0
11 49 138 0.47 74 MBM 6
05C 3.53 TEC TEH 0.61 CBAY2 55 H
87 0
11 105 138 0.4 89 PCT 14 P2 VS3
-0.83 TEH TEC 0.61 CBAY2 212 C
5 0
11 111 138 0.24 42 PCT 10 P2 BW2
-1.01 TEH TEC 0.61 CBAY2 208 C
88 0
11 157 138 0.28 138 PCT 10 P2 BW2 0.8 TEH TEC 0.61 CBAY2 246 C
98 0
11 58 139 0.29 128 PCT 10 P2 BW2
-0.52 TEC TEH 0.61 CBAY2 53 H
120 0
11 102 139 0.31 108 PCT 12 P2 VS4
-0.77 TEH TEC 0.61 CBAY2 212 C
31 0
11 106 139 0.35 94 PCT 13 P2 VS4
-0.7 TEH TEC 0.61 CBAY2 212 C
33 0
11 122 139 0.51 128 PCT 13 P2 VS1 0.76 TEH TEC 0.61 CBAY2 244 C
31 0
11 140 139 0.35 115 PCT 13 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 238 C
142 0
11 39 140 0.27 98 PCT 10 P2 BW2 1.06 TEC TEH 0.61 CBAY2 53 H
155 0
11 101 140 0.37 138 PCT 11 P2 BW1 1
TEH TEC 0.61 CBAY2 210 C
12 0
11 125 140 0.27 134 PCT 10 P2 VS1
-0.76 TEH TEC 0.61 CBAY2 246 C
15 0
11 125 140 0.35 117 PCT 12 P2 VS2
-0.73 TEH TEC 0.61 CBAY2 246 C
15 0
11 135 140 0.33 87 PCT 10 P2 BW2 1.05 TEH TEC 0.61 CBAY2 240 C
43 0
11 159 140 0.34 104 PCT 10 P2 BW2 0.94 TEH TEC 0.61 CBAY2 244 C
97 0
11 58 141 0.3 72 PCT 10 P2 VS4 0.72 TEC TEH 0.61 CBAY2 57 H
215 0
11 152 141 0.49 95 PCT 13 P2 BW2
-0.92 TEH TEC 0.61 CBAY2 244 C
101 0
11 158 141 0.82 123 PCT 19 P2 BW2
-1 TEH TEC 0.61 CBAY2 244 C
98 0
11 33 142 0.21 130 PCT 10 P2 VS3 0.9 TEC TEH 0.61 CBAY2 59 H
8 0
11 35 142 0.29 105 PCT 12 P2 BW1 0.89 TEC TEH 0.61 CBAY2 59 H
7 0
11 41 142 0.3 66 PCT 13 P2 BW1
-0.89 TEC TEH 0.61 CBAY2 55 H
108 0
11 47 142 0.27 80 PCT 12 P2 BW1 0.79 TEC TEH 0.61 CBAY2 59 H
214 0
11 101 142 0.32 72 PCT 12 P2 VS2 0.91 TEH TEC 0.61 CBAY2 212 C
51 0
11 105 142 0.28 75 PCT 11 P2 VS3
-0.92 TEH TEC 0.61 CBAY2 212 C
49 0
11 109 142 0.29 102 PCT 11 P2 BW1
-0.68 TEH TEC 0.61 CBAY2 212 C
47 0
11 117 142 0.29 103 PCT 11 P2 BW1 0.88 TEH TEC 0.61 CBAY2 212 C
43 0
11 125 142 0.35 84 PCT 10 P2 BW2 0.89 TEH TEC 0.61 CBAY2 244 C
18 0
11 155 142 0.44 133 PCT 15 P2 BW2 0.79 TEH TEC 0.61 CBAY2 250 C
5 0
11 20 143 0.29 75 PCT 13 P2 BW2 1
TEC TEH 0.61 CBAY2 59 H
24 0
11 46 143 0.31 142 PCT 13 P2 BW1 0.76 TEC TEH 0.61 CBAY2 59 H
182 0
11 50 143 0.24 51 PCT 11 P2 BW1
-0.9 TEC TEH 0.61 CBAY2 59 H
184 0
11 90 143 0.27 74 PCT 11 P2 VS4 0.98 TEH TEC 0.61 CBAY2 212 C
69 0
11 104 143 0.57 119 PCT 18 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 212 C
76 0
11 112 143 0.38 134 PCT 13 P2 BW2
-1.14 TEH TEC 0.61 CBAY2 212 C
80 0
11 114 143 0.3 89 PCT 11 P2 BW2
-0.99 TEH TEC 0.61 CBAY2 212 C
81 0
11 134 143 0.3 87 PCT 11 P2 BW2
-0.93 TEH TEC 0.61 CBAY2 242 C
17 0
11 152 143 0.4 128 PCT 14 P2 BW2 0.84 TEH TEC 0.61 CBAY2 250 C
7 0
11 154 143 0.27 53 PCT 11 P2 BW2
-0.87 TEH TEC 0.61 CBAY2 250 C
28 0
11 39 144 0.76 101 MBM 6
07H 21.95 TEC TEH 0.61 CBAY2 57 H
31 0
11 43 144 0.27 86 PCT 10 P2 BW1
-1.06 TEC TEH 0.61 CBAY2 57 H
207 0
11 43 144 0.28 95 PCT 10 P2 BW1 1.01 TEC TEH 0.61 CBAY2 57 H
207 0
11 47 144 0.32 82 PCT 11 P2 BW1 0.95 TEC TEH 0.61 CBAY2 57 H
205 0
11 87 144 0.33 113 PCT 10 P2 BW2
-0.94 TEH TEC 0.61 CBAY2 210 C
63 0
SG 11 Summary Data Sheets Page 25 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 119 144 0.35 108 PCT 10 P2 BW2 0.5 TEH TEC 0.61 CBAY2 210 C
47 0
11 129 144 0.36 150 PCT 11 P2 BW2 0.87 TEH TEC 0.61 CBAY2 240 C
62 0
11 135 144 0.4 82 PCT 14 P2 VS1
-0.79 TEH TEC 0.61 CBAY2 238 C
147 0
11 135 144 0.38 112 PCT 14 P2 BW2 0.77 TEH TEC 0.61 CBAY2 238 C
147 0
11 139 144 0.39 125 PCT 12 P2 VS1
-0.79 TEH TEC 0.61 CBAY2 236 C
142 0
11 141 144 2.17 97 WAR 27 0.17 P5 VS3
-0.8 VS3 TEH 0.61 NYAX2 63 H
9 F
0 11 141 144 1.19 125 PCT 25 P2 VS3
-0.87 TEH TEC 0.61 CBAY2 236 C
138 0
11 153 144 0.3 120 PCT 12 P2 BW2 0.9 TEH TEC 0.61 CBAY2 250 C
27 0
11 44 145 0.18 142 PCT 7
P2 VS3
-0.76 TEC TEH 0.61 CBAY2 57 H
172 0
11 46 145 0.3 123 PCT 10 P2 BW1 0.98 TEC TEH 0.61 CBAY2 57 H
173 0
11 50 145 0.27 120 PCT 10 P2 BW1
-0.8 TEC TEH 0.61 CBAY2 57 H
175 0
11 84 145 0.4 141 PCT 11 P2 VS3 1.05 TEH TEC 0.61 CBAY2 210 C
69 0
11 106 145 0.34 142 PCT 10 P2 BW1
-1.32 TEH TEC 0.61 CBAY2 210 C
80 0
11 31 146 0.34 144 PCT 14 P2 BW1 0.95 TEC TEH 0.61 CBAY2 59 H
40 0
11 47 146 0.28 136 PCT 12 P2 BW1 0.89 TEC TEH 0.61 CBAY2 59 H
177 0
11 77 146 0.24 67 PCT 10 P2 BW1 1.02 TEH TEC 0.61 CBAY2 254 C
59 0
11 99 146 0.28 66 PCT 11 P2 VS2 0.83 TEH TEC 0.61 CBAY2 212 C
106 0
11 105 146 0.36 91 PCT 13 P2 VS2 0.91 TEH TEC 0.61 CBAY2 212 C
103 0
11 109 146 0.24 156 PCT 10 P2 BW1
-0.74 TEH TEC 0.61 CBAY2 212 C
101 0
11 111 146 0.28 76 PCT 11 P2 01H
-0.74 TEH TEC 0.61 CBAY2 212 C
100 0
11 111 146 0.28 94 PCT 11 P2 BW1 1.01 TEH TEC 0.61 CBAY2 212 C
100 0
11 113 146 0.3 60 PCT 11 P2 BW2 0.95 TEH TEC 0.61 CBAY2 212 C
99 0
11 117 146 0.31 122 PCT 12 P2 VS2 0.98 TEH TEC 0.61 CBAY2 212 C
97 0
11 123 146 0.5 135 PCT 13 P2 VS3
-0.82 TEH TEC 0.61 CBAY2 244 C
15 0
11 70 147 0.22 91 PCT 10 P2 VS2 0.58 TEC TEH 0.61 CBAY2 59 H
160 0
11 76 147 0.22 67 PCT 10 P2 VS2 0.76 TEC TEH 0.61 CBAY2 59 H
163 0
11 84 147 0.31 132 PCT 12 P2 VS2 0.96 TEH TEC 0.61 CBAY2 212 C
120 0
11 86 147 0.43 110 PCT 15 P2 VS2 0.99 TEH TEC 0.61 CBAY2 212 C
121 0
11 100 147 0.24 83 PCT 10 P2 VS2 0.93 TEH TEC 0.61 CBAY2 212 C
127 0
11 102 147 0.25 74 PCT 10 P2 VS2 0.91 TEH TEC 0.61 CBAY2 212 C
128 0
11 104 147 0.51 126 PCT 16 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 212 C
129 0
11 114 147 0.44 51 PCT 15 P2 BW2
-0.7 TEH TEC 0.61 CBAY2 212 C
134 0
11 118 147 0.36 78 PCT 13 P2 BW2
-1.04 TEH TEC 0.61 CBAY2 212 C
136 0
11 120 147 0.31 131 PCT 11 P2 BW2
-1 TEH TEC 0.61 CBAY2 212 C
137 0
11 126 147 2.58 111 WAR 29 0.55 P13 VS2 1.16 VS3 TEH 0.61 NYAX2 63 H
8 T
0 11 126 147 1.31 117 PCT 26 P2 VS2 1.17 TEH TEC 0.61 CBAY2 240 C
65 0
11 35 148 0.25 98 PCT 9
P2 BW1
-0.99 TEC TEH 0.61 CBAY2 57 H
64 0
11 45 148 0.42 90 PCT 13 P2 BW1 0.95 TEC TEH 0.61 CBAY2 57 H
169 0
11 89 148 0.38 101 PCT 11 P2 BW1 0.95 TEH TEC 0.61 CBAY2 210 C
129 0
11 99 148 0.49 139 PCT 13 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 210 C
124 0
11 101 148 0.62 112 PCT 16 P2 BW1
-0.87 TEH TEC 0.61 CBAY2 210 C
123 0
11 103 148 0.56 141 PCT 15 P2 BW1
-0.86 TEH TEC 0.61 CBAY2 210 C
122 0
11 107 148 0.3 108 PCT 9
P2 BW1
-1.92 TEH TEC 0.61 CBAY2 210 C
120 0
11 109 148 0.5 96 PCT 13 P2 BW1
-1.98 TEH TEC 0.61 CBAY2 210 C
119 0
11 115 148 0.8 128 PCT 19 P2 VS3
-0.59 TEH TEC 0.61 CBAY2 210 C
116 0
11 139 148 0.51 118 PCT 17 P2 VS1 0.82 TEH TEC 0.61 CBAY2 238 C
119 0
11 139 148 0.26 80 PCT 10 P2 VS4
-0.83 TEH TEC 0.61 CBAY2 238 C
119 0
11 141 148 2.32 281 WAR 28 0.28 P5 VS3
-0.63 VS3 TEH 0.61 NYAX2 63 H
5 T
0 11 141 148 1.28 127 PCT 26 P2 VS3
-0.72 TEH TEC 0.61 CBAY2 236 C
120 0
11 12 149 0.31 26 PCT 10 P2 06C
-0.78 TEC TEH 0.61 CBAY2 57 H
77 0
11 58 149 0.42 135 PCT 13 P2 BW1 0.74 TEC TEH 0.61 CBAY2 57 H
142 0
11 62 149 0.29 104 PCT 10 P2 BW1 0.95 TEC TEH 0.61 CBAY2 57 H
144 0
SG 11 Summary Data Sheets Page 26 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 62 149 0.26 134 PCT 9
P2 VS3
-0.89 TEC TEH 0.61 CBAY2 57 H
144 0
11 68 149 0.32 107 PCT 11 P2 BW1
-0.97 TEC TEH 0.61 CBAY2 57 H
147 0
11 68 149 0.3 133 PCT 10 P2 VS2 0.79 TEC TEH 0.61 CBAY2 57 H
147 0
11 78 149 0.24 98 PCT 9
P2 VS2 0.71 TEC TEH 0.61 CBAY2 57 H
152 0
11 84 149 1.73 106 WAR 25 0.31 P12 VS2 1.25 VS3 TEH 0.61 NYAX2 63 H
12 F
0 11 84 149 0.66 138 PCT 16 P2 VS2 0.99 TEH TEC 0.61 CBAY2 210 C
136 0
11 116 149 0.31 112 PCT 9
P2 BW2 0.44 TEH TEC 0.61 CBAY2 210 C
152 0
11 140 149 0.3 100 PCT 9
P2 BW1
-0.84 TEH TEC 0.61 CBAY2 236 C
121 0
11 27 150 0.83 86 MBM 6
06C 12.69 TEC TEH 0.61 CBAY2 59 H
72 0
11 35 150 0.22 67 PCT 10 P2 BW1 0.91 TEC TEH 0.61 CBAY2 59 H
68 0
11 41 150 0.2 117 PCT 10 P2 BW2
-0.81 TEC TEH 0.61 CBAY2 59 H
65 0
11 51 150 0.25 111 PCT 10 P2 BW1
-0.89 TEH TEC 0.61 CBAY2 254 C
56 0
11 59 150 0.4 91 PCT 16 P2 VS2
-1.06 TEC TEH 0.61 CBAY2 59 H
142 0
11 63 150 0.29 71 PCT 13 P2 BW1
-0.47 TEC TEH 0.61 CBAY2 59 H
141 0
11 79 150 0.33 128 PCT 12 P2 BW1 0.83 TEH TEC 0.61 CBAY2 212 C
159 0
11 81 150 0.29 83 PCT 11 P2 09C 0.78 TEH TEC 0.61 CBAY2 212 C
158 0
11 95 150 0.29 93 PCT 11 P2 BW1 1.03 TEH TEC 0.61 CBAY2 212 C
151 0
11 95 150 0.32 103 PCT 12 P2 VS2
-0.62 TEH TEC 0.61 CBAY2 212 C
151 0
11 101 150 3.28 90 WAR 32 0.28 P5 VS3
-0.73 VS3 TEH 0.61 NYAX2 63 H
11 T
0 11 101 150 1.73 106 PCT 32 P2 VS3
-0.86 TEH TEC 0.61 CBAY2 212 C
148 0
11 101 150 PID P2 VS3
-0.86 TEH TEC 0.61 CBAY2 274 C
21 0
11 105 150 0.33 97 PCT 12 P2 VS2
-0.99 TEH TEC 0.61 CBAY2 212 C
146 0
11 109 150 0.31 76 PCT 12 P2 VS3
-0.85 TEH TEC 0.61 CBAY2 212 C
144 0
11 111 150 0.25 91 PCT 10 P2 01H
-0.75 TEH TEC 0.61 CBAY2 212 C
143 0
11 131 150 0.38 129 PCT 11 P2 VS2
-0.69 TEH TEC 0.61 CBAY2 240 C
17 0
11 34 151 0.21 142 PCT 10 P2 BW1
-0.99 TEC TEH 0.61 CBAY2 59 H
92 0
11 68 151 0.27 83 PCT 12 P2 BW1
-0.96 TEC TEH 0.61 CBAY2 59 H
130 0
11 70 151 0.28 118 PCT 12 P2 VS2 0.78 TEC TEH 0.61 CBAY2 59 H
131 0
11 82 151 0.29 139 PCT 11 P2 BW1 0.93 TEH TEC 0.61 CBAY2 212 C
162 0
11 84 151 0.41 120 PCT 14 P2 VS2 0.96 TEH TEC 0.61 CBAY2 212 C
163 0
11 102 151 0.32 111 PCT 12 P2 VS2 0.85 TEH TEC 0.61 CBAY2 212 C
172 0
11 104 151 0.41 119 PCT 14 P2 BW1 0.77 TEH TEC 0.61 CBAY2 212 C
173 0
11 110 151 0.29 33 PCT 11 P2 BW1 1
TEH TEC 0.61 CBAY2 212 C
176 0
11 114 151 0.3 108 PCT 11 P2 VS4
-0.85 TEH TEC 0.61 CBAY2 212 C
178 0
11 122 151 0.36 144 PCT 10 P2 VS1 0.64 TEH TEC 0.61 CBAY2 240 C
69 0
11 148 151 0.34 138 PCT 9
P2 11H 0.84 TEH TEC 0.61 CBAY2 248 C
16 0
11 35 152 0.47 115 PCT 15 P2 BW1 1.11 TEC TEH 0.61 CBAY2 57 H
95 0
11 43 152 0.32 138 PCT 11 P2 BW1 0.98 TEC TEH 0.61 CBAY2 57 H
133 0
11 45 152 0.34 98 PCT 11 P2 BW1 0.87 TEC TEH 0.61 CBAY2 57 H
132 0
11 79 152 0.27 128 PCT 8
P2 VS2
-0.61 TEH TEC 0.61 CBAY2 252 C
32 0
11 79 152 0.22 72 PCT 9
P2 VS2
-0.73 TEH TEC 0.61 CBAY2 254 C
61 0
11 85 152 0.44 44 PCT 12 P2 BW2
-0.79 TEH TEC 0.61 CBAY2 210 C
175 0
11 87 152 0.44 89 PCT 12 P2 BW2
-0.87 TEH TEC 0.61 CBAY2 210 C
174 0
11 91 152 0.39 104 PCT 11 P2 BW2
-0.93 TEH TEC 0.61 CBAY2 210 C
172 0
11 117 152 0.67 133 PCT 17 P2 VS3 1
TEH TEC 0.61 CBAY2 210 C
159 0
11 135 152 0.37 128 PCT 14 P2 VS1
-0.78 TEH TEC 0.61 CBAY2 238 C
115 0
11 135 152 0.25 96 PCT 10 P2 VS4
-0.9 TEH TEC 0.61 CBAY2 238 C
115 0
11 137 152 2.54 107 WAR 29 0.27 P32 VS4
-1.07 VS3 TEC 0.61 NYAX2 62 C
23 F
0 11 137 152 1.24 121 PCT 25 P2 VS4
-0.8 TEH TEC 0.61 CBAY2 236 C
124 0
11 141 152 0.29 88 PCT 11 P2 VS1
-0.83 TEH TEC 0.61 CBAY2 238 C
99 0
11 141 152 0.28 116 PCT 11 P2 VS4
-0.77 TEH TEC 0.61 CBAY2 238 C
99 0
11 147 152 NDF P4 TSH 0.05 01H TEH 0.61 NYAX2 63 H
6 0
SG 11 Summary Data Sheets Page 27 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 147 152 0.94 66 DTI P7 TSH 0.05 TEH TEC 0.61 CBAY2 248 C
17 0
11 132 153 0.5 126 PCT 15 P2 11H
-1.15 TEH TEC 0.61 CBAY2 238 C
131 0
11 79 154 0.24 31 PCT 10 P2 BW1 0.88 TEH TEC 0.61 CBAY2 212 C
203 0
11 79 154 0.28 71 PCT 11 P2 VS4
-0.69 TEH TEC 0.61 CBAY2 212 C
203 0
11 81 154 0.26 142 PCT 10 P2 09C 0.8 TEH TEC 0.61 CBAY2 212 C
202 0
11 85 154 0.25 103 PCT 10 P2 VS4
-0.74 TEH TEC 0.61 CBAY2 212 C
200 0
11 89 154 0.25 58 PCT 10 P2 VS2
-0.6 TEH TEC 0.61 CBAY2 212 C
198 0
11 89 154 0.31 125 PCT 12 P2 BW2 0.98 TEH TEC 0.61 CBAY2 212 C
198 0
11 93 154 0.25 118 PCT 10 P2 VS2 1.01 TEH TEC 0.61 CBAY2 212 C
196 0
11 119 154 0.28 126 PCT 11 P2 BW2 0.93 TEH TEC 0.61 CBAY2 212 C
183 0
11 125 154 0.48 117 PCT 16 P2 VS3
-0.83 TEH TEC 0.61 CBAY2 238 C
157 0
11 137 154 0.3 145 PCT 10 P2 VS4
-0.69 TEH TEC 0.61 CBAY2 236 C
113 0
11 68 155 0.26 101 PCT 12 P2 BW1
-0.9 TEC TEH 0.61 CBAY2 59 H
105 0
11 68 155 0.22 117 PCT 10 P2 VS2 0.74 TEC TEH 0.61 CBAY2 59 H
105 0
11 78 155 0.3 93 PCT 11 P2 VS2 1.01 TEH TEC 0.61 CBAY2 212 C
204 0
11 86 155 0.26 76 PCT 10 P2 VS4 0.88 TEH TEC 0.61 CBAY2 212 C
208 0
11 90 155 0.2 49 PCT 8
P2 10H
-0.5 TEH TEC 0.61 CBAY2 212 C
210 0
11 104 155 0.29 112 PCT 11 P2 BW1 1.03 TEH TEC 0.61 CBAY2 212 C
217 0
11 140 155 0.27 123 PCT 11 P2 VS2
-0.76 TEH TEC 0.61 CBAY2 238 C
97 0
11 41 156 0.45 127 PCT 12 P2 BW2
-0.79 TEH TEC 0.61 CBAY2 228 C
25 0
11 79 156 0.29 121 PCT 10 P2 09C 0.85 TEH TEC 0.61 CBAY2 238 C
19 0
11 87 156 0.33 124 PCT 10 P2 VS3
-0.49 TEH TEC 0.61 CBAY2 210 C
218 0
11 87 156 0.29 123 PCT 9
P2 09C 0.89 TEH TEC 0.61 CBAY2 210 C
218 0
11 113 156 0.27 140 PCT 8
P2 VS1
-0.55 TEH TEC 0.61 CBAY2 210 C
205 0
11 119 156 0.33 148 PCT 10 P2 BW1 0.92 TEH TEC 0.61 CBAY2 210 C
202 0
11 121 156 0.43 154 PCT 12 P2 BW1 0.87 TEH TEC 0.61 CBAY2 210 C
201 0
11 135 156 1.89 108 WAR 26 0.31 P12 VS2
-0.44 VS3 TEH 0.61 NYAX2 63 H
7 T
0 11 135 156 0.84 105 PCT 20 P2 VS2
-0.34 TEH TEC 0.61 CBAY2 236 C
111 0
11 68 157 0.31 48 PCT 11 P2 BW1
-0.9 TEC TEH 0.61 CBAY2 57 H
112 0
11 68 157 0.28 141 PCT 10 P2 VS2 0.76 TEC TEH 0.61 CBAY2 57 H
112 0
11 80 157 0.35 90 PCT 10 P2 BW2
-0.15 TEH TEC 0.61 CBAY2 210 C
222 0
11 112 157 0.26 116 PCT 8
P2 BW2
-1.53 TEH TEC 0.61 CBAY2 210 C
238 0
11 33 158 0.34 122 PCT 9
P2 BW1 0.96 TEH TEC 0.61 CBAY2 222 C
71 0
11 75 158 0.41 122 PCT 12 P2 VS2
-0.77 TEH TEC 0.61 CBAY2 236 C
21 0
11 105 158 0.26 102 PCT 10 P2 VS2
-0.81 TEH TEC 0.61 CBAY2 212 C
234 0
11 109 158 0.43 126 PCT 15 P2 BW1
-1.02 TEH TEC 0.61 CBAY2 212 C
232 0
11 109 158 0.64 124 PCT 19 P2 VS4
-1 TEH TEC 0.61 CBAY2 212 C
232 0
11 111 158 0.33 112 PCT 12 P2 BW1 1.07 TEH TEC 0.61 CBAY2 212 C
231 0
11 111 158 0.4 88 PCT 14 P2 VS3
-0.77 TEH TEC 0.61 CBAY2 212 C
231 0
11 115 158 0.24 117 PCT 10 P2 VS2
-0.93 TEH TEC 0.61 CBAY2 212 C
229 0
11 119 158 0.41 117 PCT 14 P2 BW1 0.85 TEH TEC 0.61 CBAY2 212 C
227 0
11 121 158 0.35 98 PCT 13 P2 VS3
-0.8 TEH TEC 0.61 CBAY2 212 C
226 0
11 62 159 0.81 90 MBM 6
02C 25.33 TEH TEC 0.61 CBAY2 224 C
43 0
11 84 159 0.36 106 PCT 13 P2 VS2 0.98 TEH TEC 0.61 CBAY2 216 C
19 0
11 84 159 0.27 131 PCT 11 P2 VS3 1.02 TEH TEC 0.61 CBAY2 216 C
19 0
11 88 159 0.27 66 PCT 11 P2 VS2 1.06 TEH TEC 0.61 CBAY2 216 C
21 0
11 88 159 0.29 105 PCT 11 P2 VS3 0.97 TEH TEC 0.61 CBAY2 216 C
21 0
11 94 159 0.27 113 PCT 11 P2 VS3 1
TEH TEC 0.61 CBAY2 216 C
24 0
11 106 159 0.25 96 PCT 10 P2 BW2
-1.45 TEH TEC 0.61 CBAY2 216 C
30 0
11 108 159 0.33 95 PCT 12 P2 BW2
-1.86 TEH TEC 0.61 CBAY2 216 C
31 0
11 5
160 0.29 149 PCT 11 P2 BW1
-0.55 TEH TEC 0.61 CBAY2 268 C
156 0
11 41 160 0.93 82 MBM 6
01C 5.5 TEH TEC 0.61 CBAY2 224 C
29 0
SG 11 Summary Data Sheets Page 28 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 119 160 0.33 153 PCT 10 P2 BW1 0.85 TEH TEC 0.61 CBAY2 210 C
246 0
11 127 160 0.39 126 PCT 14 P2 VS2
-0.82 TEH TEC 0.61 CBAY2 238 C
108 0
11 127 160 0.3 66 PCT 12 P2 VS5
-0.23 TEH TEC 0.61 CBAY2 238 C
108 0
11 68 161 0.32 96 PCT 10 P2 VS2 0.92 TEH TEC 0.61 CBAY2 236 C
13 0
11 86 161 0.38 150 PCT 11 P2 VS2 0.96 TEH TEC 0.61 CBAY2 214 C
19 0
11 92 161 0.3 154 PCT 9
P2 VS2 0.99 TEH TEC 0.61 CBAY2 214 C
22 0
11 106 161 0.66 140 PCT 16 P2 BW2
-1.52 TEH TEC 0.61 CBAY2 214 C
29 0
11 108 161 0.4 142 PCT 11 P2 BW2
-1.56 TEH TEC 0.61 CBAY2 214 C
30 0
11 83 162 0.28 107 PCT 11 P2 VS2
-0.8 TEH TEC 0.61 CBAY2 238 C
48 0
11 85 162 0.26 107 PCT 11 P2 VS2
-0.8 TEH TEC 0.61 CBAY2 238 C
47 0
11 87 162 0.25 30 PCT 10 P2 BW2 0.88 TEH TEC 0.61 CBAY2 238 C
46 0
11 87 162 0.2 29 PCT 9
P2 09C
-0.96 TEH TEC 0.61 CBAY2 238 C
46 0
11 89 162 0.45 104 PCT 15 P2 BW2 0.85 TEH TEC 0.61 CBAY2 238 C
45 0
11 97 162 0.25 146 PCT 10 P2 BW1
-0.76 TEH TEC 0.61 CBAY2 238 C
41 0
11 109 162 0.28 146 PCT 11 P2 BW1
-0.53 TEH TEC 0.61 CBAY2 238 C
36 0
11 111 162 0.36 128 PCT 13 P2 BW1 0.88 TEH TEC 0.61 CBAY2 238 C
33 0
11 117 162 0.35 121 PCT 13 P2 BW1 0.8 TEH TEC 0.61 CBAY2 238 C
79 0
11 26 163 0.26 72 PCT 11 P2 BW1
-0.83 TEH TEC 0.61 CBAY2 220 C
297 0
11 26 163 1.1 93 MBM 6
08C 2.34 TEH TEC 0.61 CBAY2 220 C
297 0
11 28 163 0.33 109 PCT 13 P2 BW1 1.13 TEH TEC 0.61 CBAY2 220 C
296 0
11 76 163 0.39 139 PCT 14 P2 VS2 0.76 TEH TEC 0.61 CBAY2 250 C
137 0
11 76 163 0.23 113 PCT 10 P2 VS3 0.88 TEH TEC 0.61 CBAY2 250 C
137 0
11 84 163 0.59 130 PCT 14 P2 VS2 0.78 TEH TEC 0.61 CBAY2 248 C
146 0
11 86 163 0.28 123 PCT 11 P2 VS2 0.81 TEH TEC 0.61 CBAY2 238 C
49 0
11 106 163 0.38 127 PCT 14 P2 BW2
-1.27 TEH TEC 0.61 CBAY2 238 C
59 0
11 122 163 0.32 103 PCT 12 P2 VS4
-0.82 TEH TEC 0.61 CBAY2 238 C
67 0
11 124 163 NDF P5 VS1
-0.82 VS3 TEH 0.61 NYAX2 61 H
48 0
11 124 163 2.16 175 DNT P1 VS1
-0.82 TEH TEC 0.61 CBAY2 238 C
68 0
11 132 163 0.26 113 PCT 11 P2 VS3
-0.99 TEH TEC 0.61 CBAY2 238 C
89 0
11 23 164 0.27 138 PCT 11 P2 BW1 0.91 TEH TEC 0.61 CBAY2 220 C
256 0
11 33 164 0.25 84 PCT 10 P2 BW2
-0.87 TEH TEC 0.61 CBAY2 220 C
261 0
11 35 164 0.26 71 PCT 11 P2 VS3
-0.77 TEH TEC 0.61 CBAY2 220 C
262 0
11 63 164 0.32 28 PCT 12 P2 BW1 1.01 TEH TEC 0.61 CBAY2 220 C
276 0
11 79 164 0.83 140 PCT 13 P2 09C 0.88 TEH TEC 0.61 CBAY2 248 C
149 0
11 111 164 0.33 147 PCT 10 P2 BW1 1.07 TEH TEC 0.61 CBAY2 236 C
75 0
11 113 164 0.33 133 PCT 10 P2 BW1 0.87 TEH TEC 0.61 CBAY2 236 C
74 0
11 115 164 0.32 130 PCT 10 P2 BW1 0.87 TEH TEC 0.61 CBAY2 236 C
73 0
11 115 164 0.42 127 PCT 12 P2 BW2 0.77 TEH TEC 0.61 CBAY2 236 C
73 0
11 117 164 0.46 144 PCT 13 P2 BW1 0.95 TEH TEC 0.61 CBAY2 236 C
72 0
11 121 164 0.39 132 PCT 12 P2 VS4 0.84 TEH TEC 0.61 CBAY2 236 C
70 0
11 127 164 0.34 148 PCT 10 P2 BW2 0.84 TEH TEC 0.61 CBAY2 236 C
67 0
11 129 164 0.51 133 PCT 14 P2 VS1 0.71 TEH TEC 0.61 CBAY2 236 C
66 0
11 129 164 0.48 96 PCT 14 P2 BW2 0.79 TEH TEC 0.61 CBAY2 236 C
66 0
11 26 165 0.83 83 MBM 6
02C 11.07 TEH TEC 0.61 CBAY2 218 C
286 0
11 84 165 0.24 145 PCT 7
P2 VS2 0.77 TEH TEC 0.61 CBAY2 248 C
166 0
11 100 165 0.38 118 PCT 12 P2 VS2 0.99 TEH TEC 0.61 CBAY2 236 C
51 0
11 132 165 1.26 141 WAR 21 0.17 P18 11H 1.04 11H TEH 0.61 NYAX2 61 H
49 F
0 11 132 165 0.86 109 PCT 20 P2 11H 1
TEH TEC 0.61 CBAY2 236 C
82 0
11 132 165 0.24 131 PCT 8
P2 BW1
-0.77 TEH TEC 0.61 CBAY2 236 C
82 0
11 132 165 0.32 155 PCT 10 P2 VS1
-0.74 TEH TEC 0.61 CBAY2 236 C
82 0
11 134 165 NDF P42 TSC 0.94 01C TEC 0.61 NYAX2 58 C
15 0
11 134 165 0.32 137 PCT 10 P2 VS3 0.73 TEH TEC 0.61 CBAY2 236 C
81 0
SG 11 Summary Data Sheets Page 29 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 134 165 0.14 43 NQI P1 TSC 0.94 TEH TEC 0.61 CBAY2 236 C
81 0
11 49 166 1.11 80 MBM 6
06H 4.96 TEH TEC 0.61 CBAY2 218 C
260 0
11 113 166 0.28 105 PCT 11 P2 VS1
-0.76 TEH TEC 0.61 CBAY2 250 C
46 0
11 40 167 0.31 84 PCT 12 P2 BW1
-0.79 TEH TEC 0.61 CBAY2 220 C
232 0
11 56 167 0.25 69 PCT 10 P2 BW2
-1.68 TEH TEC 0.61 CBAY2 220 C
223 0
11 56 167 0.8 87 MBM 6
03C 16.91 TEH TEC 0.61 CBAY2 220 C
223 0
11 84 167 0.19 133 PCT 8
P2 VS2 0.71 TEH TEC 0.61 CBAY2 250 C
80 0
11 86 167 0.49 131 PCT 17 P2 BW2
-0.82 TEH TEC 0.61 CBAY2 250 C
81 0
11 88 167 0.35 94 PCT 13 P2 BW2
-0.89 TEH TEC 0.61 CBAY2 250 C
82 0
11 25 168 0.23 137 PCT 10 P2 BW1 0.97 TEH TEC 0.61 CBAY2 220 C
198 0
11 31 168 0.27 117 PCT 11 P2 VS3
-0.68 TEH TEC 0.61 CBAY2 220 C
201 0
11 37 168 0.25 69 PCT 10 P2 BW1
-0.91 TEH TEC 0.61 CBAY2 220 C
204 0
11 41 168 0.3 116 PCT 12 P2 BW1 0.94 TEH TEC 0.61 CBAY2 220 C
206 0
11 47 168 0.28 128 PCT 11 P2 BW1 0.92 TEH TEC 0.61 CBAY2 220 C
209 0
11 55 168 0.35 102 PCT 13 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 220 C
213 0
11 57 168 0.29 76 PCT 11 P2 BW1
-1.06 TEH TEC 0.61 CBAY2 220 C
214 0
11 59 168 0.29 66 PCT 11 P2 BW1 0.94 TEH TEC 0.61 CBAY2 220 C
215 0
11 61 168 0.34 144 PCT 13 P2 BW1
-0.92 TEH TEC 0.61 CBAY2 220 C
216 0
11 61 168 0.29 36 PCT 11 P2 BW1 0.96 TEH TEC 0.61 CBAY2 220 C
216 0
11 79 168 0.46 124 PCT 11 P2 BW2 0.94 TEH TEC 0.61 CBAY2 248 C
77 0
11 101 168 0.43 134 PCT 11 P2 BW1 1.11 TEH TEC 0.61 CBAY2 248 C
66 0
11 101 168 0.63 96 PCT 14 P2 VS3
-0.78 TEH TEC 0.61 CBAY2 248 C
66 0
11 117 168 0.25 126 PCT 7
P2 BW1
-0.85 TEH TEC 0.61 CBAY2 248 C
58 0
11 119 168 0.41 136 PCT 10 P2 BW1 0.85 TEH TEC 0.61 CBAY2 248 C
57 0
11 127 168 0.49 147 PCT 12 P2 BW1 0.87 TEH TEC 0.61 CBAY2 248 C
53 0
11 38 169 NDF P22 VS3
-0.71 VS3 TEH 0.61 NYAX2 61 H
43 0
11 38 169 2.85 180 DNT P1 VS3
-0.71 TEH TEC 0.61 CBAY2 218 C
224 0
11 120 169 0.49 143 PCT 12 P2 BW2
-0.94 TEH TEC 0.61 CBAY2 248 C
112 0
11 128 169 NDF P18 TSC 1.11 01C TEC 0.61 NYAX2 58 C
16 0
11 128 169 2.74 178 DNT P1 TSC 1.11 TEH TEC 0.61 CBAY2 248 C
116 0
11 29 170 0.61 125 PCT 16 P2 VS3 0.89 TEH TEC 0.61 CBAY2 218 C
191 0
11 31 170 0.32 134 PCT 10 P2 VS3 0.79 TEH TEC 0.61 CBAY2 218 C
192 0
11 39 170 0.63 86 PCT 16 P2 BW2 0.96 TEH TEC 0.61 CBAY2 218 C
196 0
11 41 170 0.59 103 PCT 15 P2 BW2
-0.88 TEH TEC 0.61 CBAY2 218 C
197 0
11 49 170 0.36 81 PCT 11 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 218 C
201 0
11 111 170 0.23 86 PCT 10 P2 BW2
-0.87 TEH TEC 0.61 CBAY2 250 C
105 0
11 113 170 0.2 91 PCT 9
P2 BW2 0.78 TEH TEC 0.61 CBAY2 250 C
104 0
11 117 170 0.27 117 PCT 11 P2 BW1 0.08 TEH TEC 0.61 CBAY2 250 C
102 0
11 119 170 0.31 107 PCT 12 P2 VS2
-0.83 TEH TEC 0.61 CBAY2 250 C
101 0
11 121 170 0.39 132 PCT 14 P2 VS2 0.73 TEH TEC 0.61 CBAY2 250 C
100 0
11 125 170 0.27 107 PCT 11 P2 BW1 1.01 TEH TEC 0.61 CBAY2 250 C
98 0
11 38 171 NDF P11 VS3
-0.79 VS3 TEH 0.61 NYAX2 61 H
42 0
11 38 171 2.61 177 DNT P1 VS3
-0.79 TEH TEC 0.61 CBAY2 220 C
177 0
11 94 171 0.16 108 PCT 7
P2 VS2 0.63 TEH TEC 0.61 CBAY2 254 C
22 0
11 116 171 0.31 109 PCT 12 P2 BW1 1.07 TEH TEC 0.61 CBAY2 254 C
33 0
11 43 172 0.25 136 PCT 10 P2 BW1 0.91 TEH TEC 0.61 CBAY2 220 C
152 0
11 45 172 0.24 34 PCT 10 P2 BW1 0.97 TEH TEC 0.61 CBAY2 220 C
153 0
11 123 172 0.38 103 PCT 10 P2 VS3
-1.27 TEH TEC 0.61 CBAY2 248 C
117 0
11 122 173 0.38 131 PCT 10 P2 VS4
-0.87 TEH TEC 0.61 CBAY2 260 C
19 0
11 103 174 0.3 135 PCT 12 P2 BW1
-0.86 TEH TEC 0.61 CBAY2 258 C
44 0
11 84 175 0.38 153 PCT 11 P2 VS2 0.63 TEH TEC 0.61 CBAY2 256 C
28 0
11 84 175 0.46 137 PCT 13 P2 VS4
-0.89 TEH TEC 0.61 CBAY2 256 C
28 0
SG 11 Summary Data Sheets Page 30 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 55 176 0.29 94 PCT 11 P2 BW2 1.75 TEH TEC 0.61 CBAY2 220 C
103 0
11 103 176 0.34 152 PCT 9
P2 BW1 0.82 TEH TEC 0.61 CBAY2 260 C
27 0
11 82 177 0.39 134 PCT 11 P2 09C 0.86 TEH TEC 0.61 CBAY2 264 C
34 0
11 106 177 0.35 101 PCT 9
P2 BW2
-0.77 TEH TEC 0.61 CBAY2 260 C
9 0
11 108 177 0.38 133 PCT 10 P2 BW2
-0.95 TEH TEC 0.61 CBAY2 260 C
10 0
11 112 177 0.55 113 PCT 13 P2 BW2
-0.97 TEH TEC 0.61 CBAY2 260 C
12 0
11 5
178 0.44 82 PCT 15 P2 02C 0.89 TEH TEC 0.61 CBAY2 268 C
74 0
11 49 178 0.23 108 PCT 7
P2 BW1
-0.89 TEH TEC 0.61 CBAY2 218 C
97 0
11 91 178 0.26 105 PCT 10 P2 BW2
-0.82 TEH TEC 0.61 CBAY2 264 C
28 0
11 101 178 0.23 70 PCT 10 P2 BW1 0.93 TEH TEC 0.61 CBAY2 258 C
51 0
11 48 179 0.24 99 PCT 10 P2 09C
-0.32 TEH TEC 0.61 CBAY2 220 C
62 0
11 88 179 0.39 74 PCT 10 P2 BW2
-0.8 TEH TEC 0.61 CBAY2 262 C
29 0
11 92 179 0.29 91 PCT 8
P2 BW2
-0.82 TEH TEC 0.61 CBAY2 262 C
27 0
11 104 179 0.29 126 PCT 11 P2 BW2
-0.89 TEH TEC 0.61 CBAY2 258 C
55 0
11 39 180 0.23 83 PCT 10 P2 VS3
-0.81 TEH TEC 0.61 CBAY2 220 C
40 0
11 39 180 0.38 61 PCT 14 P2 BW2 1.11 TEH TEC 0.61 CBAY2 220 C
40 0
11 53 180 0.35 127 PCT 13 P2 BW1
-0.62 TEH TEC 0.61 CBAY2 220 C
47 0
11 57 180 0.29 84 PCT 12 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 220 C
49 0
11 69 180 0.36 75 PCT 10 P2 BW2 1.15 TEH TEC 0.61 CBAY2 262 C
42 0
11 77 180 0.39 104 PCT 10 P2 BW1 1.01 TEH TEC 0.61 CBAY2 262 C
46 0
11 79 180 0.43 77 PCT 11 P2 VS4
-0.6 TEH TEC 0.61 CBAY2 262 C
47 0
11 85 180 0.33 89 PCT 9
P2 BW1 0.58 TEH TEC 0.61 CBAY2 262 C
50 0
11 87 180 1.06 133 WAR 20 0.21 P7 BW1 1.04 VS3 TEH 0.61 NYAX2 61 H
45 F
0 11 87 180 1.03 100 PCT 21 P2 BW1 1.01 TEH TEC 0.61 CBAY2 262 C
51 0
11 87 180 0.55 140 PCT 10 P2 09C 0.81 TEH TEC 0.61 CBAY2 262 C
51 0
11 89 180 0.44 119 PCT 11 P2 BW1
-0.26 TEH TEC 0.61 CBAY2 262 C
52 0
11 91 180 0.37 92 PCT 10 P2 BW1 0.09 TEH TEC 0.61 CBAY2 262 C
53 0
11 95 180 0.42 142 PCT 11 P2 BW1
-0.9 TEH TEC 0.61 CBAY2 260 C
30 0
11 97 180 0.27 135 PCT 8
P2 BW1
-0.91 TEH TEC 0.61 CBAY2 260 C
29 0
11 99 180 0.45 77 PCT 11 P2 BW1
-0.89 TEH TEC 0.61 CBAY2 260 C
31 0
11 109 180 0.32 105 PCT 9
P2 VS3 0.81 TEH TEC 0.61 CBAY2 260 C
36 0
11 56 181 0.34 146 PCT 10 P2 VS3
-1 TEH TEC 0.61 CBAY2 218 C
55 0
11 88 181 0.28 139 PCT 10 P2 BW1
-0.93 TEH TEC 0.61 CBAY2 264 C
57 0
11 100 181 0.29 103 PCT 8
P2 BW2
-0.94 TEH TEC 0.61 CBAY2 260 C
46 0
11 6
183 0.25 106 PCT 11 P2 08H
-1.09 TEH TEC 0.61 CBAY2 266 C
54 0
11 8
183 0.29 144 PCT 9
P2 BW1 1.11 TEH TEC 0.61 CBAY2 266 C
53 0
11 24 183 0.25 131 PCT 10 P2 BW1 1.05 TEH TEC 0.61 CBAY2 220 C
19 0
11 82 183 0.5 72 PCT 13 P2 BW2
-0.03 TEH TEC 0.61 CBAY2 262 C
57 0
11 86 183 0.47 100 PCT 12 P2 BW2
-0.1 TEH TEC 0.61 CBAY2 262 C
55 0
11 19 184 NDF 23 08H 3.74 6.24 VS3 TEH 0.61 NYAX2 61 H
41 0
11 19 184 2.43 290 PRX P8 08H 3.74 6.24 TEH TEC 0.61 CBAY2 216 C
251 0
11 43 184 0.29 94 PCT 11 P2 BW1 1.03 TEH TEC 0.61 CBAY2 216 C
263 0
11 71 184 0.21 221 PCT 6
P2 BW1 0.94 TEH TEC 0.61 CBAY2 262 C
68 0
11 83 184 0.44 112 PCT 12 P2 BW1 0.52 TEH TEC 0.61 CBAY2 262 C
74 0
11 10 185 0.22 153 PCT 9
P2 BW1
-0.69 TEH TEC 0.61 CBAY2 268 C
43 0
11 78 185 0.36 149 PCT 10 P2 09C 0.82 TEH TEC 0.61 CBAY2 264 C
87 0
11 90 185 0.29 120 PCT 11 P2 BW1
-0.74 TEH TEC 0.61 CBAY2 264 C
17 0
11 92 185 2.14 178 DNT P1 09H 19.07 TEH TEC 0.61 CBAY2 262 C
24 0
11 92 185 0.46 115 PCT 12 P2 BW2
-0.37 TEH TEC 0.61 CBAY2 262 C
24 0
11 94 185 0.3 130 PCT 8
P2 BW1
-0.79 TEH TEC 0.61 CBAY2 262 C
17 0
11 98 185 0.4 120 PCT 11 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 262 C
10 0
11 67 186 NDF P12 TSH 0
01H TEH 0.61 NYAX2 61 H
44 0
SG 11 Summary Data Sheets Page 31 of 32 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 11 58 187 0.25 65 PCT 10 P2 BW2 0.9 TEH TEC 0.61 CBAY2 216 C
223 0
11 60 187 0.25 115 PCT 10 P2 BW1
-1 TEH TEC 0.61 CBAY2 216 C
222 0
11 92 187 NDF P5 09H 29.37 10H TEH 0.61 NYAX2 61 H
46 0
11 92 187 6.02 179 DNT P1 09H 29.37 TEH TEC 0.61 CBAY2 262 C
19 0
11 85 188 0.64 140 PCT 11 P2 09C 0.73 TEH TEC 0.61 CBAY2 262 C
95 0
11 42 189 0.83 73 MBM 6
06C 12.68 TEH TEC 0.61 CBAY2 214 C
200 0
11 82 189 1.08 56 MBM 6
06H 19.85 TEH TEC 0.61 CBAY2 264 C
106 0
11 30 191 0.27 127 PCT 11 P2 VS3
-0.8 TEH TEC 0.61 CBAY2 216 C
181 0
11 48 191 0.25 128 PCT 10 P2 BW2 1.02 TEH TEC 0.61 CBAY2 216 C
172 0
11 78 191 0.38 133 PCT 10 P2 VS4
-0.78 TEH TEC 0.61 CBAY2 262 C
100 0
11 3
192 13.88 118 PLP 124 03H 33.31 08H TEH 0.61 NYAX2 61 H
30 HR 0
11 3
192 1.38 108 PLP 8
03H 33.61 TEH TEC 0.61 CBAY2 268 C
29 HR 0
11 13 192 0.52 139 PCT 13 P2 08C 0.72 TEH TEC 0.61 CBAY2 216 C
139 0
11 43 192 0.75 90 MBM 6
FDP 28.82 TEH TEC 0.61 CBAY2 216 C
153 0
11 37 194 NDF P14 VS3 0.56 VS3 TEH 0.61 NYAX2 61 H
39 0
11 37 194 3.1 180 DNT P1 VS3 0.56 TEH TEC 0.61 CBAY2 214 C
123 0
11 45 194 0.28 147 PCT 8
P2 BW2
-0.92 TEH TEC 0.61 CBAY2 214 C
127 0
11 49 194 0.31 71 PCT 9
P2 BW1 0.96 TEH TEC 0.61 CBAY2 214 C
129 0
11 55 194 1.45 83 MBM 6
06H 6.86 TEH TEC 0.61 CBAY2 214 C
132 0
11 46 195 0.32 154 PCT 10 P2 08H
-0.79 TEH TEC 0.61 CBAY2 216 C
120 0
11 46 195 0.24 134 PCT 10 P2 BW2 0.96 TEH TEC 0.61 CBAY2 216 C
120 0
11 52 195 0.26 135 PCT 10 P2 BW1 0.98 TEH TEC 0.61 CBAY2 216 C
117 0
11 60 195 0.31 122 PCT 10 P2 09C 0.1 TEH TEC 0.61 CBAY2 216 C
91 0
11 17 200 NDF P22 TEC 0.53 01C TEC 0.61 NYAX2 60 C
5 0
11 17 200 48.89 189 OXP 2
TEC 0.53 TEH TEC 0.61 CBAY2 216 C
48 0
11 29 202 NDF P13 TSH 1.13 01H TEH 0.61 NYAX2 61 H
38 0
11 29 202 2.01 182 DNT P1 TSH 1.13 TEH TEC 0.61 CBAY2 214 C
53 0
11 12 203 2.1 178 DNT P1 TSC 11.46 TEH TEC 0.61 CBAY2 214 C
44 0
SG 11 Summary Data Sheets Page 32 of 32 1R23 Spring 2022
APPENDIX C STEAM GENERATOR 12
SUMMARY
DATA SHEETS
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 32 3
2.9 181 DNT P1 VS3 0.78 VS3 TEH 0.61 CBAY2 49 H
84 0
12 32 3
NDF P8 VS3 0.68 VS3 TEH 0.61 NYAX2 57 H
33 0
12 41 4
0.26 51 PCT 10 P2 BW1
-0.79 TEH TEC 0.61 CBAY2 10 C
118 0
12 22 5
0.26 126 PCT 9
P2 BW1 0.95 VS3 TEH 0.61 CBAY2 43 H
176 0
12 50 5
6.1 181 DNT P1 08C 9.48 TEH TEC 0.61 CBAY2 10 C
126 0
12 50 5
5.2 181 DNT P1 08C 11.98 TEH TEC 0.61 CBAY2 10 C
126 0
12 50 5
2.46 182 DNT P1 FDP 22.81 TEH TEC 0.61 CBAY2 10 C
126 0
12 50 5
NDF P2 08C 9.47 09C TEC 0.61 NYAX2 264 C
6 0
12 50 5
NDF P8 08C 11.98 09C TEC 0.61 NYAX2 264 C
6 0
12 55 8
0.33 151 PCT 10 P2 09H
-0.74 TEH TEC 0.61 CBAY2 14 C
11 0
12 48 9
0.24 99 PCT 10 P2 09C
-0.37 TEH TEC 0.61 CBAY2 14 C
23 0
12 61 10 0.2 64 PCT 7
P2 VS3
-0.86 TEH TEC 0.61 CBAY2 16 C
8 0
12 55 12 0.56 126 PCT 18 P2 BW2
-1.62 TEH TEC 0.61 CBAY2 14 C
38 0
12 67 12 0.24 101 PCT 10 P2 BW2 0.91 TEH TEC 0.61 CBAY2 14 C
32 0
12 58 13 0.34 76 DSI P6 FDP 0.58 TEH TEC 0.61 CBAY2 14 C
54 0
12 58 13 3.24 119 PLP 39 FDP 0.67 01C TEC 0.61 NYAX2 264 C
5 HR 0
12 53 14 2.61 136 LNI P7 TSH
-0.03 TEH TEC 0.61 CBAY2 16 C
40 0
12 53 14 NDF P17 TSH
-0.03 01H TEH 0.61 NYAX2 57 H
31 0
12 83 16 0.62 142 PCT 18 P2 VS3
-0.61 VS3 TEH 0.61 CBAY2 41 H
215 0
12 78 17 0.33 127 PCT 11 P2 VS3 0.58 VS3 TEH 0.61 CBAY2 71 H
172 0
12 92 17 0.94 109 PCT 23 P2 VS3
-0.96 VS3 TEH 0.61 CBAY2 41 H
202 0
12 92 17 0.88 94 WAR 18 0.23 P15 VS3
-1.03 VS3 TEH 0.61 NYAX2 67 H
7 F
0 12 98 19 0.23 157 NQI 3
TSH 0.84 01H TEH 0.61 CBAY2 41 H
193 0
12 98 19 NDF P14 TSH 0.84 01H TEH 0.61 NYAX2 57 H
22 0
12 67 20 2.58 327 LNI P7 TSH
-0.06 TEH TEC 0.61 CBAY2 14 C
87 0
12 67 20 NDF 60 TSH
-0.06 01H TEH 0.61 NYAX2 57 H
26 0
12 78 21 0.3 72 PCT 10 P2 BW2 0.7 VS3 TEC 0.61 CBAY2 70 C
113 0
12 51 22 0.2 126 PCT 7
P2 VS3 1.14 TEH TEC 0.61 CBAY2 16 C
97 0
12 51 22 2.04 180 DNT P1 08C 15.03 TEH TEC 0.61 CBAY2 16 C
97 0
12 98 23 0.33 127 PCT 11 P2 VS2 0.76 VS3 TEH 0.61 CBAY2 73 H
218 0
12 13 24 0.4 146 PCT 10 P2 08C 0.71 TEH TEC 0.61 CBAY2 32 C
57 0
12 107 24 0.23 155 PCT 10 P2 VS2
-0.98 VS3 TEH 0.61 CBAY2 41 H
181 0
12 32 25 3.01 178 DNT P1 VS3
-1.06 TEH TEC 0.61 CBAY2 32 C
69 0
12 32 25 NDF P30 VS3
-1.06 VS3 TEH 0.61 NYAX2 57 H
32 0
12 72 25 0.46 90 PCT 14 P2 VS2 0.71 VS3 TEH 0.61 CBAY2 71 H
244 0
12 78 25 0.41 75 PCT 12 P2 VS2
-0.94 VS3 TEH 0.61 CBAY2 71 H
241 0
12 57 26 3.23 180 DNT P1 07H 2.66 TEH TEC 0.61 CBAY2 20 C
96 0
12 57 26 NDF P11 07H 2.66 09H TEH 0.61 NYAX2 57 H
27 0
12 56 27 6.91 180 DNT P1 03H 1.8 TEH TEC 0.61 CBAY2 20 C
104 0
12 56 27 NDF P8 03H 1.52 09H TEH 0.61 NYAX2 57 H
28 0
12 106 27 0.27 70 PCT 10 P2 VS3 0.96 VS3 TEC 0.61 CBAY2 68 C
157 0
12 39 28 0.31 106 PCT 10 P2 VS3 0.81 TEH TEC 0.61 CBAY2 36 C
12 0
12 47 28 0.32 110 PCT 11 P2 BW1 0.95 TEH TEC 0.61 CBAY2 20 C
116 0
12 97 30 0.31 116 PCT 10 P2 VS2
-0.9 VS3 TEH 0.61 CBAY2 73 H
291 0
12 119 30 0.31 83 PCT 10 P2 VS2
-0.56 VS3 TEH 0.61 CBAY2 75 H
67 0
12 90 31 2.64 176 DNT P1 BW2 5.82 VS3 TEC 0.61 CBAY2 54 C
67 0
12 118 31 0.34 140 PCT 12 P2 BW1
-0.89 VS3 TEH 0.61 CBAY2 41 H
165 0
12 122 31 0.35 59 PCT 11 P2 VS2
-1.04 VS3 TEH 0.61 CBAY2 75 H
65 0
SG 12 Summary Data Sheets Page 1 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 29 32 0.28 158 PCT 11 P2 BW1 1.03 TEH TEC 0.61 CBAY2 28 C
113 0
12 111 32 0.38 72 PCT 12 P2 BW1
-0.93 VS3 TEH 0.61 CBAY2 71 H
311 0
12 123 32 0.41 104 PCT 12 P2 VS3 0.83 VS3 TEH 0.61 CBAY2 75 H
64 0
12 76 33 0.38 76 PCT 12 P2 VS2 0.83 VS3 TEH 0.61 CBAY2 75 H
29 0
12 118 33 0.3 139 PCT 10 P2 VS1
-0.74 VS3 TEH 0.61 CBAY2 75 H
8 0
12 118 33 0.56 88 PCT 15 P2 VS1 0.74 VS3 TEH 0.61 CBAY2 75 H
8 0
0 12 124 33 1.2 118 PCT 25 P2 10H
-0.08 VS3 TEH 0.61 CBAY2 41 H
134 0
12 124 33 2.16 96 WAR 27 0.15 P2 10H
-0.09 10H TEH 0.61 NYAX2 57 H
19 F
0 12 111 34 0.4 81 PCT 14 P2 BW2
-0.84 VS3 TEC 0.61 CBAY2 42 C
129 0
12 25 36 0.26 42 PCT 10 P2 BW1
-0.86 TEH TEC 0.61 CBAY2 32 C
9 0
12 91 36 0.35 125 PCT 11 P2 VS2 0.23 VS3 TEH 0.61 CBAY2 75 H
36 0
12 125 36 0.43 110 PCT 14 P2 VS3
-1 VS3 TEC 0.61 CBAY2 46 C
10 0
12 10 37 0.32 131 PCT 10 P2 BW1
-0.56 VS3 TEH 0.61 CBAY2 109 H
98 0
12 120 37 0.47 94 PCT 16 P2 VS3
-0.8 VS3 TEC 0.61 CBAY2 42 C
121 0
12 128 37 1.07 272 PRX P8 10C 21 27 VS3 TEC 0.61 CBAY2 54 C
66 0
12 128 37 2.1 147 BOW 55 10C 32.61 33.9 VS3 TEC 0.61 NYAX2 264 C
45 0
12 130 37 1.9 265 PRX P8 10C 21.96 22.34 VS3 TEC 0.61 CBAY2 54 C
65 0
12 130 37 1.5 132 BOW 151 10C 21.5 22.5 VS3 TEC 0.61 NYAX2 264 C
44 0
12 61 38 0.18 100 PCT 7
P2 09C 0.75 TEH TEC 0.61 CBAY2 6
C 156 0
12 65 38 0.29 53 PCT 10 P2 BW1 0.34 TEH TEC 0.61 CBAY2 6
C 158 0
12 77 38 0.24 93 PCT 10 P2 VS4
-0.81 VS3 TEC 0.61 CBAY2 42 C
105 0
12 115 38 0.3 63 PCT 10 P2 VS4
-0.79 VS3 TEC 0.61 CBAY2 74 C
131 0
12 125 38 0.44 123 PCT 13 P2 VS2 0.77 VS3 TEH 0.61 CBAY2 43 H
53 0
12 62 39 0.26 97 PCT 10 P2 VS3 0.87 TEH TEC 0.61 CBAY2 6
C 147 0
12 76 39 0.44 126 PCT 13 P2 VS2 0.79 VS3 TEH 0.61 CBAY2 75 H
109 0
12 86 39 0.15 130 PCT 5
P2 VS2
-0.69 VS3 TEH 0.61 CBAY2 39 H
190 0
12 102 39 0.13 145 PCT 5
P2 VS2
-0.87 VS3 TEH 0.61 CBAY2 39 H
189 0
12 35 40 0.32 94 PCT 10 P2 VS3 0.83 TEH TEC 0.61 CBAY2 36 C
137 0
12 119 40 0.58 107 PCT 15 P2 VS2
-0.96 VS3 TEH 0.61 CBAY2 39 H
209 0
12 125 40 1.45 108 PCT 27 P2 VS2
-1.04 VS3 TEH 0.61 CBAY2 39 H
208 0
12 125 40 1.81 110 PCT 30 P2 VS2
-0.77 VS3 TEH 0.61 CBAY2 39 H
208 0
12 125 40 2.58 110 WAR 29 0.17 P6 VS2
-0.98 VS3 TEH 0.61 NYAX2 57 H
18 F
0 12 125 40 3.16 108 WAR 32 0.2 P6 VS2
-0.68 VS3 TEH 0.61 NYAX2 57 H
18 F
0 12 129 40 0.33 64 PCT 11 P2 VS5
-0.74 VS3 TEC 0.61 CBAY2 74 C
105 0
12 135 40 0.51 93 PCT 16 P2 VS3
-0.89 VS3 TEC 0.61 CBAY2 46 C
121 0
12 135 40 0.26 110 PCT 10 P2 VS3 0.92 VS3 TEC 0.61 CBAY2 46 C
121 0
12 10 41 0.31 116 PCT 12 P2 BW2
-0.72 VS3 TEC 0.61 CBAY2 258 C
64 0
12 118 41 0.3 89 PCT 10 P2 VS5
-0.71 VS3 TEC 0.61 CBAY2 74 C
171 0
12 118 41 0.37 139 PCT 11 P2 VS2
-0.69 VS3 TEH 0.61 CBAY2 85 H
70 0
12 120 41 0.34 151 PCT 11 P2 BW1 0.79 VS3 TEH 0.61 CBAY2 85 H
68 0
12 122 41 0.39 134 PCT 11 P2 VS1 0.78 VS3 TEH 0.61 CBAY2 81 H
49 0
12 97 42 0.3 128 PCT 10 P2 BW2 0.85 VS3 TEC 0.61 CBAY2 74 C
190 0
12 101 42 0.26 36 PCT 8
P2 BW1 0.95 VS3 TEH 0.61 CBAY2 39 H
188 0
12 117 42 0.51 102 PCT 14 P2 VS2
-0.96 VS3 TEH 0.61 CBAY2 39 H
206 0
12 117 42 0.28 111 PCT 11 P2 VS4
-0.85 VS3 TEC 0.61 CBAY2 42 C
40 0
12 121 42 0.54 111 PCT 15 P2 VS3
-0.83 VS3 TEH 0.61 CBAY2 85 H
67 13 0
12 137 42 0.43 142 PCT 15 P2 BW1 0.8 VS3 TEH 0.61 CBAY2 41 H
148 0
12 137 42 0.29 123 PCT 11 P2 VS3 0.9 VS3 TEC 0.61 CBAY2 46 C
123 0
SG 12 Summary Data Sheets Page 2 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 32 43 0.39 131 PCT 12 P2 VS3
-0.78 TEH TEC 0.61 CBAY2 36 C
190 0
12 36 43 0.35 111 PCT 11 P2 VS3
-0.78 TEH TEC 0.61 CBAY2 36 C
192 0
12 92 43 0.39 105 PCT 12 P2 BW1
-0.92 VS3 TEH 0.61 CBAY2 39 H
187 0
12 94 43 0.28 93 PCT 9
P2 BW1
-0.9 VS3 TEH 0.61 CBAY2 39 H
186 0
12 102 43 0.35 88 PCT 11 P2 BW1
-0.9 VS3 TEH 0.61 CBAY2 39 H
185 0
12 102 43 0.26 73 PCT 10 P2 VS3
-0.67 VS3 TEC 0.61 CBAY2 42 C
44 0
12 120 43 0.45 85 PCT 15 P2 VS3 1.03 VS3 TEC 0.61 CBAY2 42 C
45 0
12 122 43 0.32 142 PCT 10 P2 VS1 0.39 VS3 TEH 0.61 CBAY2 39 H
205 0
12 122 43 0.94 118 PCT 21 P2 VS2 0.83 VS3 TEH 0.61 CBAY2 39 H
205 0
12 122 43 0.87 101 PCT 22 P2 VS3 1.01 VS3 TEC 0.61 CBAY2 42 C
46 0
12 122 43 2.03 117 WAR 27 0.38 P14 VS2 0.84 VS3 TEH 0.61 NYAX2 57 H
13 T
0 12 122 43 1.84 108 WAR 25 0.17 P14 VS3 0.5 VS3 TEH 0.61 NYAX2 57 H
13 T
0 12 128 43 0.36 149 PCT 13 P2 VS1
-0.81 VS3 TEH 0.61 CBAY2 41 H
5 0
12 128 43 0.25 57 PCT 10 P2 VS5 0.86 VS3 TEC 0.61 CBAY2 42 C
95 0
12 130 43 0.63 110 PCT 19 P2 BW2
-0.89 VS3 TEC 0.61 CBAY2 42 C
96 0
12 59 44 0.24 64 PCT 8
P2 VS3 0.97 TEH TEC 0.61 CBAY2 8
C 124 0
12 75 44 1.39 105 PCT 28 P2 VS3
-0.9 VS3 TEC 0.61 CBAY2 44 C
19 0
12 75 44 3.37 112 WAR 33 0.32 P6 VS3
-0.79 VS3 TEH 0.61 NYAX2 57 H
35 F
0 12 85 44 0.32 126 PCT 10 P2 VS2 0.68 VS3 TEH 0.61 CBAY2 39 H
184 0
12 123 44 0.66 112 PCT 17 P2 VS2 0.66 VS3 TEH 0.61 CBAY2 39 H
203 0
12 127 44 0.31 147 PCT 10 P2 BW1 0.86 VS3 TEH 0.61 CBAY2 81 H
43 0
12 139 44 0.4 134 PCT 14 P2 BW1 1
VS3 TEH 0.61 CBAY2 41 H
11 0
12 114 45 0.34 109 PCT 11 P2 VS2 0.87 VS3 TEH 0.61 CBAY2 85 H
102 0
12 116 45 0.33 98 PCT 10 P2 VS2
-0.9 VS3 TEH 0.61 CBAY2 85 H
91 0
12 120 45 0.54 103 PCT 15 P2 VS4
-0.91 VS3 TEC 0.61 CBAY2 44 C
20 0
12 124 45 0.71 111 PCT 17 P2 VS2 0.88 VS3 TEH 0.61 CBAY2 39 H
202 0
12 128 45 0.34 148 PCT 10 P2 VS1
-0.7 VS3 TEH 0.61 CBAY2 39 H
211 0
12 128 45 0.6 116 PCT 16 P2 VS1 0.72 VS3 TEH 0.61 CBAY2 39 H
211 0
12 5
46 3.37 41 NTE 2
TSH
-0.4 01H TEH 0.61 CBAY2 55 H
50 0
12 5
46 NDF P17 TSH
-0.4 01H TEH 0.61 NYAX2 59 H
57 0
12 59 46 0.27 120 PCT 10 P2 BW1 0.7 TEH TEC 0.61 CBAY2 6
C 125 0
12 81 46 0.26 140 PCT 8
P2 VS2
-0.74 VS3 TEH 0.61 CBAY2 39 H
182 0
12 81 46 0.3 108 PCT 11 P2 VS4
-0.74 VS3 TEC 0.61 CBAY2 42 C
49 0
12 113 46 0.34 106 PCT 12 P2 BW2 0.4 VS3 TEC 0.61 CBAY2 42 C
48 0
12 119 46 0.37 133 PCT 11 P2 BW1
-0.71 VS3 TEH 0.61 CBAY2 81 H
79 0
12 133 46 5.4 179 DNT P1 VS5
-1.77 VS3 TEC 0.61 CBAY2 54 C
64 0
12 133 46 NDF P28 VS5
-1.77 VS3 TEC 0.61 NYAX2 274 C
25 0
12 48 47 0.12 76 DSI P1 09C
-0.03 TEH TEC 0.61 CBAY2 10 C
99 0
12 48 47 0.33 40 PCT 10 P2 09C 0.02 TEH TEC 0.61 CBAY2 10 C
99 0
12 48 47 NDF P40 09C
-0.03 09C TEC 0.61 NYAX2 264 C
21 0
12 72 47 0.25 57 PCT 10 P2 VS3
-0.92 VS3 TEC 0.61 CBAY2 42 C
50 0
12 110 47 0.35 101 PCT 11 P2 BW1
-0.86 VS3 TEH 0.61 CBAY2 39 H
198 0
12 122 47 0.61 109 PCT 18 P2 VS3
-0.75 VS3 TEC 0.61 CBAY2 42 C
52 0
12 134 47 0.3 109 PCT 10 P2 VS3 1.17 VS3 TEC 0.61 CBAY2 294 C
77 0
12 142 47 0.29 151 PCT 10 P2 BW1 0.92 VS3 TEH 0.61 CBAY2 85 H
10 0
12 51 48 0.43 116 PCT 13 P2 VS3 0.87 TEH TEC 0.61 CBAY2 8
C 105 0
12 95 48 0.3 93 PCT 10 P2 VS2
-0.96 VS3 TEH 0.61 CBAY2 87 H
11 0
12 115 48 0.33 132 PCT 10 P2 BW1 0.39 VS3 TEH 0.61 CBAY2 39 H
197 0
SG 12 Summary Data Sheets Page 3 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 115 48 0.42 121 PCT 12 P2 VS2
-0.9 VS3 TEH 0.61 CBAY2 39 H
197 0
12 129 48 0.4 120 PCT 12 P2 VS3
-0.89 VS3 TEH 0.61 CBAY2 81 H
56 0
12 131 48 0.49 118 PCT 14 P2 VS2
-0.7 VS3 TEH 0.61 CBAY2 39 H
212 0
12 133 48 0.31 104 PCT 10 P2 BW2 0.83 VS3 TEC 0.61 CBAY2 294 C
75 0
12 130 49 1
127 PCT 22 P2 VS1
-0.61 VS3 TEH 0.61 CBAY2 39 H
213 0
12 130 49 0.88 102 PCT 21 P2 VS3
-0.73 VS3 TEC 0.61 CBAY2 44 C
53 0
12 130 49 2.77 109 WAR 30 0.17 P14 VS1
-0.82 VS3 TEH 0.61 NYAX2 57 H
12 F
0 12 130 49 1.71 100 WAR 24 0.2 P21 VS3
-0.6 VS3 TEH 0.61 NYAX2 57 H
12 F
0 12 146 49 0.4 110 PCT 14 P2 BW1 1.01 VS3 TEH 0.61 CBAY2 41 H
99 0
12 7
50 0.28 29 PCT 9
P2 BW1
-0.7 VS3 TEH 0.61 CBAY2 53 H
153 0
12 103 50 0.32 76 PCT 10 P2 BW1 0.92 VS3 TEH 0.61 CBAY2 85 H
158 0
12 115 50 0.49 114 PCT 16 P2 VS3
-0.82 VS3 TEC 0.61 CBAY2 42 C
53 0
12 137 50 0.61 114 PCT 16 P2 VS1
-0.84 VS3 TEH 0.61 CBAY2 43 H
21 0
12 60 51 2.37 178 DNT P1 VS4
-2.31 TEH TEC 0.61 CBAY2 6
C 103 0
12 60 51 NDF P47 VS4
-2.31 VS3 TEC 0.61 NYAX2 264 C
22 0
12 78 51 0.31 91 PCT 10 P2 VS2 0.75 VS3 TEH 0.61 CBAY2 89 H
45 0
12 140 51 0.38 144 PCT 14 P2 BW1
-0.83 VS3 TEH 0.61 CBAY2 41 H
47 0
12 45 52 0.28 118 PCT 10 P2 BW1 0.89 TEH TEC 0.61 CBAY2 12 C
79 0
12 63 52 0.31 70 PCT 10 P2 BW1 0.9 TEH TEC 0.61 CBAY2 8
C 96 0
12 105 52 0.33 136 PCT 10 P2 VS2
-0.79 VS3 TEH 0.61 CBAY2 39 H
195 0
12 133 52 0.24 125 PCT 10 P2 11C
-0.93 VS3 TEC 0.61 CBAY2 292 C
101 0
12 143 52 0.33 124 PCT 12 P2 VS3 0.82 VS3 TEC 0.61 CBAY2 46 C
59 0
12 38 53 0.28 96 PCT 9
P2 VS3
-1.08 VS3 TEH 0.61 CBAY2 39 H
180 0
12 74 53 0.31 120 PCT 10 P2 VS2 0.8 VS3 TEH 0.61 CBAY2 87 H
70 0
12 118 53 0.49 74 PCT 14 P2 VS1
-0.76 VS3 TEH 0.61 CBAY2 81 H
111 0
12 124 53 0.48 140 PCT 13 P2 VS1
-0.75 VS3 TEH 0.61 CBAY2 39 H
194 0
12 124 53 3.1 103 PCT 38 P2 VS2 0.69 VS3 TEH 0.61 CBAY2 39 H
194 0
12 124 53 0.99 306 WAR 19 P14 VS1
-0.65 VS3 TEH 0.61 NYAX2 57 H
5 0
12 124 53 5.87 105 WAR 41 0.56 P6 VS2 0.84 VS3 TEH 0.61 NYAX2 57 H
5 T
0 12 126 53 0.37 126 PCT 11 P2 VS2
-0.89 VS3 TEH 0.61 CBAY2 81 H
86 0
12 128 53 0.59 135 PCT 15 P2 VS1
-0.54 VS3 TEH 0.61 CBAY2 39 H
171 0
12 128 53 0.35 122 PCT 12 P2 VS3 0.79 VS3 TEC 0.61 CBAY2 42 C
90 0
12 128 53 1.4 109 PCT 29 P2 VS3 1.15 VS3 TEC 0.61 CBAY2 42 C
90 0
12 128 53 0.26 121 PCT 10 P2 VS5 0.79 VS3 TEC 0.61 CBAY2 42 C
90 0
12 128 53 1.73 114 WAR 25 P14 VS1
-0.58 VS3 TEH 0.61 NYAX2 57 H
8 0
12 128 53 2.05 95 WAR 27 0.42 P5 VS3 1.12 VS3 TEH 0.61 NYAX2 57 H
8 T
0 12 140 53 0.44 148 PCT 13 P2 BW1
-0.86 VS3 TEH 0.61 CBAY2 85 H
33 0
12 73 54 0.27 110 PCT 10 P2 BW1 0.92 TEH TEC 0.61 CBAY2 22 C
16 0
12 115 54 0.61 111 PCT 16 P2 VS2
-0.88 VS3 TEH 0.61 CBAY2 39 H
169 0
12 115 54 0.28 72 PCT 11 P2 VS4 0.95 VS3 TEC 0.61 CBAY2 42 C
39 0
12 127 54 0.31 89 PCT 10 P2 VS3 0.51 VS3 TEC 0.61 CBAY2 44 C
52 0
12 127 54 0.88 108 PCT 21 P2 VS3 1
VS3 TEC 0.61 CBAY2 44 C
52 0
12 127 54 0.48 107 PCT 14 P2 VS4
-0.79 VS3 TEC 0.61 CBAY2 44 C
52 0
12 127 54 1.56 123 WAR 23 0.64 P30 VS3 0.79 VS3 TEH 0.61 NYAX2 67 H
5 T
0 12 127 54 1.58 131 WAR 24 0.78 P22 VS3 0.9 VS3 TEH 0.61 NYAX2 67 H
5 F
0 12 143 54 0.25 85 PCT 10 P2 BW2 0.71 VS3 TEC 0.61 CBAY2 292 C
70 0
12 145 54 0.38 106 PCT 14 P2 VS2 0.21 VS3 TEH 0.61 CBAY2 41 H
27 0
12 145 54 0.27 84 PCT 10 P2 VS4
-0.87 VS3 TEC 0.61 CBAY2 46 C
61 0
SG 12 Summary Data Sheets Page 4 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 145 54 0.3 51 PCT 11 P2 BW2 0.83 VS3 TEC 0.61 CBAY2 46 C
61 0
12 114 55 0.39 136 PCT 12 P2 VS2
-0.83 VS3 TEH 0.61 CBAY2 39 H
168 0
12 114 55 1.26 124 PCT 28 P2 VS3
-0.96 VS3 TEC 0.61 CBAY2 42 C
38 0
12 114 55 0.62 124 PCT 18 P2 VS3
-0.63 VS3 TEC 0.61 CBAY2 42 C
38 0
12 114 55 1.41 104 WAR 22 0.97 P13 VS3
-0.84 VS3 TEH 0.61 NYAX2 57 H
4 T
0 12 116 55 0.38 138 PCT 11 P2 VS2
-0.86 VS3 TEH 0.61 CBAY2 39 H
167 0
12 122 55 0.25 102 PCT 8
P2 VS2 0.9 VS3 TEH 0.61 CBAY2 39 H
166 0
12 122 55 0.41 88 PCT 14 P2 VS5
-0.78 VS3 TEC 0.61 CBAY2 42 C
36 0
12 130 55 0.43 137 PCT 12 P2 VS2
-0.76 VS3 TEH 0.61 CBAY2 39 H
165 0
12 134 55 0.24 83 PCT 8
P2 BW1
-0.92 VS3 TEH 0.61 CBAY2 39 H
164 0
12 101 56 0.23 70 PCT 8
P2 BW1 1.01 VS3 TEH 0.61 CBAY2 39 H
162 0
12 101 56 0.32 142 PCT 10 P2 VS2 0.75 VS3 TEH 0.61 CBAY2 39 H
162 0
12 113 56 0.46 120 PCT 13 P2 VS2
-0.83 VS3 TEH 0.61 CBAY2 39 H
163 0
12 139 56 0.52 104 PCT 14 P2 VS1
-0.88 VS3 TEH 0.61 CBAY2 93 H
159 0
12 139 56 0.24 140 PCT 10 P2 BW2 0.77 VS3 TEC 0.61 CBAY2 292 C
81 0
12 145 56 0.48 103 PCT 14 P2 VS1 0.63 VS3 TEH 0.61 CBAY2 95 H
230 0
12 145 56 0.3 112 PCT 11 P2 BW2 0.77 VS3 TEC 0.61 CBAY2 292 C
68 0
12 22 57 0.3 70 PCT 10 P2 BW1 0.54 VS3 TEH 0.61 CBAY2 87 H
170 0
12 78 57 0.38 134 PCT 11 P2 VS2
-0.79 VS3 TEH 0.61 CBAY2 39 H
161 0
12 86 57 0.3 147 PCT 9
P2 VS2
-0.73 VS3 TEH 0.61 CBAY2 39 H
160 0
12 118 57 0.45 117 PCT 13 P2 VS2 1
VS3 TEH 0.61 CBAY2 39 H
159 0
12 118 57 0.34 122 PCT 12 P2 VS3 1.21 VS3 TEC 0.61 CBAY2 42 C
58 0
12 130 57 0.47 118 PCT 13 P2 VS1 0.68 VS3 TEH 0.61 CBAY2 91 H
182 0
12 132 57 0.4 121 PCT 12 P2 VS1 0.76 VS3 TEH 0.61 CBAY2 91 H
183 0
12 134 57 0.36 140 PCT 11 P2 VS1 0.73 VS3 TEH 0.61 CBAY2 91 H
184 0
12 99 58 0.36 116 PCT 11 P2 BW1 0.95 VS3 TEH 0.61 CBAY2 91 H
141 0
12 125 58 0.34 128 PCT 10 P2 VS1 0.6 VS3 TEH 0.61 CBAY2 91 H
199 0
12 127 58 0.33 89 PCT 10 P2 VS1 0.63 VS3 TEH 0.61 CBAY2 91 H
198 0
12 131 58 0.48 126 PCT 13 P2 VS1 0.65 VS3 TEH 0.61 CBAY2 91 H
196 0
12 66 59 0.41 102 PCT 13 P2 BW1
-0.76 TEH TEC 0.61 CBAY2 6
C 70 0
12 92 59 0.38 90 PCT 11 P2 BW1
-0.76 VS3 TEH 0.61 CBAY2 39 H
174 0
12 128 59 0.39 84 PCT 11 P2 BW1
-0.9 VS3 TEH 0.61 CBAY2 39 H
154 0
12 128 59 0.25 70 PCT 10 P2 VS5
-0.8 VS3 TEC 0.61 CBAY2 42 C
89 0
12 130 59 0.36 124 PCT 11 P2 VS1 0.74 VS3 TEH 0.61 CBAY2 93 H
172 0
12 134 59 0.29 86 PCT 11 P2 BW2
-0.98 VS3 TEC 0.61 CBAY2 292 C
106 0
12 117 60 0.27 112 PCT 11 P2 VS3
-1.34 VS3 TEC 0.61 CBAY2 292 C
159 0
12 125 60 0.55 91 PCT 17 P2 VS4 0.65 VS3 TEC 0.61 CBAY2 42 C
59 0
12 135 60 0.27 128 PCT 10 P2 VS3
-1.05 VS3 TEC 0.61 CBAY2 42 C
80 0
12 135 60 0.93 119 PCT 23 P2 VS3 1.03 VS3 TEC 0.61 CBAY2 42 C
80 0
12 135 60 0.96 117 WAR 19 P6 VS3
-1.05 VS3 TEH 0.61 NYAX2 61 H
12 0
12 135 60 2.32 113 WAR 28 0.47 P22 VS3 0.84 VS3 TEH 0.61 NYAX2 61 H
12 T
0 12 155 60 0.25 114 PCT 10 P2 BW2 0.78 VS3 TEC 0.61 CBAY2 292 C
38 0
12 48 61 1.1 112 PCT 25 P2 09C
-1.55 TEH TEC 0.61 CBAY2 12 C
46 0
12 48 61 1.88 86 WAR 26 0.42 P9 09C
-1.57 09C TEC 0.61 NYAX2 264 C
23 T
0 12 60 61 0.3 134 PCT 10 P2 BW1
-0.74 TEH TEC 0.61 CBAY2 8
C 56 0
12 150 61 0.33 95 PCT 11 P2 VS3 0.79 VS3 TEC 0.61 CBAY2 44 C
48 0
12 45 62 0.45 96 PCT 15 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 10 C
57 0
12 147 62 0.48 121 PCT 13 P2 VS2 0.78 VS3 TEH 0.61 CBAY2 39 H
149 0
SG 12 Summary Data Sheets Page 5 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 147 62 1.06 112 PCT 24 P2 VS3
-0.83 VS3 TEC 0.61 CBAY2 44 C
45 0
12 147 62 1.49 118 WAR 23 P22 VS2 0.58 VS3 TEH 0.61 NYAX2 61 H
11 0
12 147 62 2.35 95 WAR 28 0.17 P6 VS3
-0.9 VS3 TEH 0.61 NYAX2 61 H
11 F
0 12 58 63 0.31 120 PCT 11 P2 BW1
-1.63 TEH TEC 0.61 CBAY2 6
C 59 0
12 96 63 0.37 156 PCT 10 P2 10C 0.84 VS3 TEC 0.61 CBAY2 292 C
253 0
12 120 63 2.12 108 PCT 32 P2 VS2
-0.7 VS3 TEH 0.61 CBAY2 39 H
147 0
12 120 63 4.19 116 WAR 36 0.51 P22 VS2
-0.73 VS3 TEH 0.61 NYAX2 59 H
56 T
0 12 130 63 0.23 126 PCT 8
P2 VS1
-0.67 VS3 TEH 0.61 CBAY2 39 H
148 0
12 150 63 1.09 113 PCT 23 P2 VS1 0.79 VS3 TEH 0.61 CBAY2 43 H
30 0
12 150 63 2.65 97 WAR 29 0.42 P7 VS1 1.01 VS3 TEH 0.61 NYAX2 61 H
10 T
0 12 150 63 1.02 106 WAR 20 0.29 P6 VS2 0.84 VS3 TEH 0.61 NYAX2 61 H
10 F
0 12 19 64 0.32 51 PCT 10 P2 BW1
-0.94 VS3 TEH 0.61 CBAY2 87 H
234 0
12 75 64 0.31 55 PCT 12 P2 VS3
-0.86 TEH TEC 0.61 CBAY2 28 C
26 0
12 85 64 0.16 152 PCT 6
P2 VS2
-0.68 VS3 TEH 0.61 CBAY2 39 H
175 0
12 117 64 0.24 143 PCT 10 P2 VS5 0.85 VS3 TEC 0.61 CBAY2 292 C
32 0
12 137 64 0.3 116 PCT 11 P2 VS3 1.18 VS3 TEC 0.61 CBAY2 292 C
22 0
12 143 64 0.24 130 PCT 10 P2 VS5
-0.72 VS3 TEC 0.61 CBAY2 292 C
19 0
12 145 64 0.3 121 PCT 10 P2 VS1
-0.92 VS3 TEH 0.61 CBAY2 95 H
273 0
12 145 64 0.26 88 PCT 10 P2 VS3
-1.1 VS3 TEC 0.61 CBAY2 292 C
18 0
12 147 64 0.31 118 PCT 12 P2 VS5
-0.67 VS3 TEC 0.61 CBAY2 42 C
74 0
12 157 64 0.24 121 PCT 10 P2 VS4
-0.57 VS3 TEC 0.61 CBAY2 292 C
13 0
12 136 65 0.42 97 PCT 13 P2 VS3 0.99 VS3 TEC 0.61 CBAY2 44 C
44 0
12 146 65 0.33 91 PCT 11 P2 VS3 0.81 VS3 TEC 0.61 CBAY2 44 C
43 0
12 39 66 0.23 133 PCT 9
P2 08C 0.77 VS3 TEC 0.61 CBAY2 256 C
13 0
12 47 66 0.52 118 PCT 16 P2 VS3
-0.61 TEH TEC 0.61 CBAY2 10 C
45 0
12 57 66 0.39 113 PCT 13 P2 BW1
-1.76 TEH TEC 0.61 CBAY2 6
C 49 0
12 111 66 0.31 55 PCT 10 P2 VS4 0.84 VS3 TEC 0.61 CBAY2 294 C
34 0
12 125 66 0.39 122 PCT 12 P2 VS1 0.81 VS3 TEH 0.61 CBAY2 39 H
143 0
12 131 66 0.22 69 PCT 8
P2 VS5 1.02 VS3 TEC 0.61 CBAY2 44 C
39 0
12 147 66 0.48 80 PCT 14 P2 VS3
-0.94 VS3 TEC 0.61 CBAY2 44 C
40 0
12 159 66 0.38 147 PCT 13 P2 BW2 0.85 VS3 TEC 0.61 CBAY2 46 C
102 0
12 28 67 0.33 77 PCT 12 P2 08C 0.91 VS3 TEC 0.61 CBAY2 68 C
5 0
12 50 67 0.33 30 PCT 12 P2 VS3
-1 TEH TEC 0.61 CBAY2 10 C
37 0
12 118 67 0.4 102 PCT 14 P2 VS3 1.16 VS3 TEC 0.61 CBAY2 42 C
62 0
12 118 67 0.33 134 PCT 12 P2 VS4 0.6 VS3 TEC 0.61 CBAY2 42 C
62 0
12 120 67 1.08 115 PCT 23 P2 VS2
-0.88 VS3 TEH 0.61 CBAY2 39 H
140 0
12 120 67 0.29 98 PCT 11 P2 VS4 0.75 VS3 TEC 0.61 CBAY2 42 C
63 0
12 120 67 2.55 124 WAR 29 0.29 P22 VS2
-0.82 VS3 TEH 0.61 NYAX2 59 H
55 F
0 12 156 67 0.52 63 PCT 16 P2 BW2
-0.92 VS3 TEC 0.61 CBAY2 46 C
29 0
12 156 67 0.41 83 PCT 14 P2 BW2 0.84 VS3 TEC 0.61 CBAY2 46 C
29 0
12 9
68 0.12 34 PCT 5
P2 BW2 0.33 VS3 TEC 0.61 CBAY2 60 C
17 0
12 63 68 0.28 80 PCT 9
P2 BW1 0.99 TEH TEC 0.61 CBAY2 8
C 37 0
12 85 68 0.29 103 PCT 9
P2 VS2
-0.94 VS3 TEH 0.61 CBAY2 39 H
176 0
12 107 68 0.24 98 PCT 10 P2 VS4
-0.69 VS3 TEC 0.61 CBAY2 292 C
199 0
12 113 68 0.15 107 PCT 5
P2 BW1 0.46 VS3 TEH 0.61 CBAY2 39 H
138 0
12 117 68 0.28 52 PCT 10 P2 VS2
-0.88 VS3 TEH 0.61 CBAY2 45 H
96 0
12 131 68 0.32 125 PCT 10 P2 BW1
-0.81 VS3 TEH 0.61 CBAY2 93 H
230 0
12 131 68 0.25 118 PCT 10 P2 VS3
-1 VS3 TEC 0.61 CBAY2 288 C
279 0
SG 12 Summary Data Sheets Page 6 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 131 68 0.26 42 PCT 10 P2 BW2 0.88 VS3 TEC 0.61 CBAY2 288 C
279 0
12 145 68 0.3 120 PCT 11 P2 VS3
-1.09 VS3 TEC 0.61 CBAY2 288 C
272 0
12 147 68 0.25 98 PCT 10 P2 VS3
-0.9 VS3 TEC 0.61 CBAY2 42 C
73 0
12 159 68 0.43 104 PCT 14 P2 BW2 0.87 VS3 TEC 0.61 CBAY2 46 C
73 0
12 36 69 0.33 148 PCT 10 P2 VS3
-1.05 VS3 TEH 0.61 CBAY2 39 H
178 0
12 86 69 0.24 138 PCT 10 P2 VS4
-0.77 VS3 TEC 0.61 CBAY2 78 C
102 0
12 118 69 0.67 109 PCT 18 P2 VS3 0.82 VS3 TEC 0.61 CBAY2 44 C
27 0
12 122 69 0.3 95 PCT 9
P2 BW1
-0.59 VS3 TEH 0.61 CBAY2 39 H
133 0
12 124 69 0.2 151 PCT 7
P2 VS1
-0.66 VS3 TEH 0.61 CBAY2 39 H
134 0
12 124 69 0.31 127 PCT 10 P2 VS2
-0.89 VS3 TEH 0.61 CBAY2 39 H
134 0
12 126 69 0.45 143 PCT 13 P2 VS1
-0.82 VS3 TEH 0.61 CBAY2 91 H
247 0
12 132 69 0.24 118 PCT 10 P2 VS4
-0.56 VS3 TEC 0.61 CBAY2 288 C
249 0
12 132 69 0.27 90 PCT 10 P2 VS5 0.77 VS3 TEC 0.61 CBAY2 288 C
249 0
12 138 69 0.45 128 PCT 13 P2 VS1 0.77 VS3 TEH 0.61 CBAY2 39 H
135 0
12 140 69 0.3 146 PCT 10 P2 VS1
-0.9 VS3 TEH 0.61 CBAY2 39 H
136 0
12 156 69 0.33 132 PCT 12 P2 BW2
-1.16 VS3 TEC 0.61 CBAY2 288 C
259 0
12 35 70 0.31 67 PCT 10 P2 BW1
-0.94 VS3 TEH 0.61 CBAY2 87 H
183 0
12 41 70 0.38 75 PCT 13 P2 BW2
-0.91 TEH TEC 0.61 CBAY2 10 C
30 0
12 83 70 0.33 119 PCT 12 P2 BW2 0.94 VS3 TEC 0.61 CBAY2 78 C
92 0
12 87 70 0.36 145 PCT 13 P2 BW2
-0.94 VS3 TEC 0.61 CBAY2 78 C
90 0
12 121 70 0.31 104 PCT 10 P2 VS4 1.15 VS3 TEC 0.61 CBAY2 44 C
30 0
12 127 70 0.49 126 PCT 14 P2 VS1
-0.7 VS3 TEH 0.61 CBAY2 39 H
130 0
12 131 70 0.51 110 PCT 14 P2 VS1
-0.78 VS3 TEH 0.61 CBAY2 91 H
261 0
12 155 70 0.3 104 PCT 10 P2 VS3
-0.68 VS3 TEC 0.61 CBAY2 48 C
15 0
12 6
71 0.57 18 NQI 3
TSH 10.69 01H TEH 0.61 CBAY2 55 H
61 0
12 6
71 NDF P27 TSH 10.69 01H TEH 0.61 NYAX2 63 H
7 0
12 24 71 4.44 182 DNT P1 VS3 4.8 BW2 TEH 0.61 CBAY2 49 H
74 0
12 32 71 0.31 79 PCT 11 P2 VS3
-0.82 VS3 TEC 0.61 CBAY2 68 C
35 0
12 38 71 0.56 122 PCT 17 P2 VS3
-0.91 VS3 TEC 0.61 CBAY2 68 C
38 11 0
12 40 71 0.39 122 PCT 13 P2 VS3
-0.97 VS3 TEC 0.61 CBAY2 68 C
39 0
12 44 71 0.38 59 PCT 13 P2 VS3 0.98 TEH TEC 0.61 CBAY2 10 C
28 0
12 46 71 0.37 77 PCT 13 P2 VS3 1.12 TEH TEC 0.61 CBAY2 10 C
27 0
12 66 71 0.26 86 PCT 10 P2 BW1
-0.72 TEH TEC 0.61 CBAY2 6
C 26 0
12 116 71 0.32 51 PCT 10 P2 BW1 0
VS3 TEH 0.61 CBAY2 87 H
352 0
12 118 71 0.38 118 PCT 12 P2 VS3 0.7 VS3 TEH 0.61 CBAY2 45 H
89 0
12 130 71 0.21 153 PCT 7
P2 VS1
-0.73 VS3 TEH 0.61 CBAY2 39 H
128 0
12 132 71 0.29 64 PCT 10 P2 VS3
-1.16 VS3 TEC 0.61 CBAY2 290 C
279 0
12 140 71 2.16 108 PCT 32 P2 VS2
-0.93 VS3 TEH 0.61 CBAY2 39 H
129 0
12 140 71 3.47 89 WAR 33 0.25 P30 VS2
-0.84 VS3 TEH 0.61 NYAX2 61 H
9 F
0 12 154 71 0.43 71 PCT 14 P2 VS3 0.89 VS3 TEC 0.61 CBAY2 42 C
124 0
12 162 71 0.26 73 PCT 9
P2 BW1
-0.93 VS3 TEH 0.61 CBAY2 45 H
15 0
12 11 72 0.42 104 PCT 12 P2 BW1 0.73 VS3 TEH 0.61 CBAY2 87 H
263 0
12 81 72 0.31 92 PCT 10 P2 BW1 0.9 VS3 TEH 0.61 CBAY2 89 H
276 0
12 89 72 0.38 139 PCT 11 P2 VS2 0.62 VS3 TEH 0.61 CBAY2 89 H
272 0
12 113 72 0.38 128 PCT 11 P2 BW1
-0.82 VS3 TEH 0.61 CBAY2 39 H
127 0
12 115 72 0.26 64 PCT 10 P2 VS3
-0.78 TEH TEC 0.61 CBAY2 42 C
18 0
12 117 72 0.32 101 PCT 12 P2 VS2 0.93 TEH TEC 0.61 CBAY2 42 C
19 0
12 123 72 0.66 99 PCT 19 P2 VS3
-0.75 VS3 TEC 0.61 CBAY2 42 C
67 0
SG 12 Summary Data Sheets Page 7 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 123 72 0.26 55 PCT 10 P2 VS5
-0.55 VS3 TEC 0.61 CBAY2 42 C
67 0
12 163 72 0.33 101 PCT 12 P2 BW2
-0.87 VS3 TEC 0.61 CBAY2 46 C
77 0
12 30 73 0.26 31 PCT 9
P2 08C 0.73 TEH TEC 0.61 CBAY2 246 C
241 0
12 40 73 0.33 84 PCT 12 P2 08C 0.79 TEH TEC 0.61 CBAY2 12 C
13 0
12 46 73 0.61 132 PCT 15 P2 08H 0.94 TEH TEC 0.61 CBAY2 12 C
10 0
12 86 73 0.33 149 PCT 10 P2 VS2
-0.83 VS3 TEH 0.61 CBAY2 89 H
254 0
12 104 73 1.16 105 PCT 26 P2 VS3 1
VS3 TEC 0.61 CBAY2 42 C
68 0
12 104 73 1.8 112 WAR 25 0.57 P14 VS3 0.84 VS3 TEH 0.61 NYAX2 59 H
54 T
0 12 116 73 2.1 178 DNT P1 08C 10.85 VS3 TEC 0.61 CBAY2 54 C
51 0
12 132 73 0.45 30 PCT 12 P2 04H
-0.79 TEH TEC 0.61 CBAY2 42 C
31 0
12 140 73 0.47 116 PCT 13 P2 VS1
-0.86 VS3 TEH 0.61 CBAY2 39 H
125 0
12 156 73 0.34 119 PCT 11 P2 VS2
-0.57 VS3 TEH 0.61 CBAY2 47 H
12 0
12 158 73 0.26 129 PCT 10 P2 VS3
-1.01 VS3 TEC 0.61 CBAY2 288 C
227 0
12 158 73 0.3 82 PCT 11 P2 BW2 0.8 VS3 TEC 0.61 CBAY2 288 C
227 0
12 160 73 0.59 123 PCT 17 P2 BW2 0.84 VS3 TEC 0.61 CBAY2 48 C
60 0
12 47 74 0.45 101 PCT 15 P2 VS3
-0.69 TEH TEC 0.61 CBAY2 10 C
19 10 0
12 63 74 0.38 123 PCT 13 P2 BW1 0.82 TEH TEC 0.61 CBAY2 6
C 21 0
12 99 74 0.24 69 PCT 10 P2 BW2 0.79 VS3 TEC 0.61 CBAY2 78 C
59 0
12 119 74 0.39 80 PCT 12 P2 VS3
-0.83 VS3 TEC 0.61 CBAY2 44 C
31 0
12 127 74 0.31 116 PCT 10 P2 VS2 0.87 VS3 TEH 0.61 CBAY2 39 H
73 0
12 129 74 0.5 130 PCT 14 P2 VS1
-0.76 VS3 TEH 0.61 CBAY2 39 H
74 0
12 159 74 0.21 99 PCT 8
P2 VS4 0.82 VS3 TEC 0.61 CBAY2 48 C
19 0
12 34 75 0.29 82 PCT 10 P2 VS3
-0.68 TEH TEC 0.61 CBAY2 246 C
213 0
12 116 75 0.3 132 PCT 10 P2 VS3 0.87 VS3 TEH 0.61 CBAY2 87 H
308 0
12 120 75 0.34 78 PCT 11 P2 VS3 0.96 VS3 TEC 0.61 CBAY2 44 C
32 0
12 132 75 0.33 148 PCT 10 P2 VS2
-0.72 VS3 TEH 0.61 CBAY2 39 H
75 0
12 156 75 1.38 111 PCT 26 P2 VS1 0.91 VS3 TEH 0.61 CBAY2 45 H
29 0
12 156 75 0.83 105 PCT 20 P2 VS2 0.81 VS3 TEH 0.61 CBAY2 45 H
29 0
12 156 75 2.26 97 WAR 28 0.43 P7 VS1 0.91 VS3 TEH 0.61 NYAX2 61 H
8 T
0 12 156 75 1.82 87 WAR 25 0.43 P6 VS2 1.07 VS3 TEH 0.61 NYAX2 61 H
8 F
0 12 160 75 0.24 77 PCT 9
P2 VS3
-0.75 VS3 TEC 0.61 CBAY2 48 C
20 0
12 160 75 0.27 70 PCT 9
P2 VS3 0.82 VS3 TEC 0.61 CBAY2 48 C
20 0
12 162 75 0.28 95 PCT 9
P2 BW1
-1 VS3 TEH 0.61 CBAY2 47 H
20 0
12 162 75 0.24 123 PCT 9
P2 VS4 0.86 VS3 TEC 0.61 CBAY2 48 C
62 0
12 164 75 0.76 130 PCT 21 P2 BW2
-0.87 VS3 TEC 0.61 CBAY2 46 C
37 0
12 164 75 1.67 102 WAR 24 0.2 P31 BW2
-0.96 VS3 TEC 0.61 NYAX2 276 C
5 F
0 12 107 76 0.33 74 PCT 10 P2 VS4
-0.89 TEC TEH 0.61 CBAY2 9
H 78 0
12 123 76 0.39 120 PCT 12 P2 VS1 0.52 TEC TEH 0.61 CBAY2 35 H
12 0
12 125 76 0.3 90 PCT 10 P2 VS3 0.47 TEC TEH 0.61 CBAY2 35 H
13 0
12 131 76 0.33 133 PCT 10 P2 VS1 0.81 TEC TEH 0.61 CBAY2 35 H
16 0
12 135 76 0.29 135 PCT 10 P2 BW2 1.12 TEC TEH 0.61 CBAY2 35 H
20 0
12 137 76 0.57 129 PCT 16 P2 VS3
-1.04 TEC TEH 0.61 CBAY2 35 H
21 0
12 147 76 0.32 71 PCT 12 P2 VS3
-1.2 VS3 TEC 0.61 CBAY2 288 C
207 0
12 159 76 0.45 82 PCT 15 P2 BW2 0.93 VS3 TEC 0.61 CBAY2 46 C
89 0
12 161 76 0.29 157 PCT 10 P2 BW1
-0.91 VS3 TEH 0.61 CBAY2 47 H
16 0
12 161 76 0.29 105 PCT 10 P2 VS3
-0.68 VS3 TEC 0.61 CBAY2 48 C
21 0
12 165 76 0.36 79 PCT 13 P2 BW2
-0.9 VS3 TEC 0.61 CBAY2 46 C
38 0
12 28 77 0.67 67 PCT 17 P2 BW2 1
TEC TEH 0.61 CBAY2 11 H
123 4
SG 12 Summary Data Sheets Page 8 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 30 77 0.41 123 PCT 11 P2 08C 0.85 TEC TEH 0.61 CBAY2 11 H
124 5
12 40 77 0.36 108 PCT 11 P2 BW2 0.88 TEC TEH 0.61 CBAY2 11 H
129 0
12 42 77 0.36 145 PCT 11 P2 VS3
-0.78 TEC TEH 0.61 CBAY2 11 H
130 0
12 46 77 0.4 75 PCT 12 P2 BW1 0.97 TEC TEH 0.61 CBAY2 11 H
132 0
12 48 77 0.23 115 PCT 8
P2 09C
-1.54 TEC TEH 0.61 CBAY2 11 H
133 0
12 90 77 0.48 71 PCT 14 P2 BW1
-0.8 TEC TEH 0.61 CBAY2 9
H 89 0
12 114 77 0.42 138 PCT 12 P2 VS2
-0.71 VS3 TEH 0.61 CBAY2 39 H
45 0
12 114 77 0.26 79 PCT 10 P2 VS3 0.9 VS3 TEC 0.61 CBAY2 54 C
47 0
12 128 77 0.8 126 PCT 19 P2 VS1
-0.73 VS3 TEH 0.61 CBAY2 39 H
44 0
12 130 77 0.56 116 PCT 15 P2 VS3 0.98 VS3 TEH 0.61 CBAY2 39 H
43 0
12 132 77 0.37 134 PCT 11 P2 VS3 0.85 VS3 TEH 0.61 CBAY2 39 H
42 0
12 166 77 0.99 94 PCT 24 P2 BW2
-0.92 VS3 TEC 0.61 CBAY2 46 C
39 0
12 166 77 1.5 118 WAR 23 0.41 P7 BW2
-0.78 VS3 TEC 0.61 NYAX2 274 C
22 T
0 12 29 78 0.32 139 PCT 10 P2 BW2
-0.93 TEC TEH 0.61 CBAY2 11 H
150 4
12 31 78 0.55 131 PCT 14 P2 08C 0.85 TEC TEH 0.61 CBAY2 11 H
149 5
12 35 78 0.34 129 PCT 11 P2 BW1
-0.95 TEC TEH 0.61 CBAY2 11 H
147 7
12 41 78 0.35 126 PCT 11 P2 BW2
-0.88 TEC TEH 0.61 CBAY2 11 H
144 0
12 47 78 0.69 114 PCT 18 P2 BW1 0.97 TEC TEH 0.61 CBAY2 11 H
141 0
12 107 78 0.28 120 PCT 9
P2 VS2 0.67 TEC TEH 0.61 CBAY2 11 H
92 0
12 30 79 0.48 144 PCT 14 P2 BW1
-0.47 TEC TEH 0.61 CBAY2 9
H 125 3
12 30 79 0.32 49 PCT 10 P2 BW2
-0.87 TEC TEH 0.61 CBAY2 9
H 125 3
12 40 79 0.38 58 PCT 11 P2 BW2
-0.85 TEC TEH 0.61 CBAY2 9
H 130 8
12 46 79 0.61 110 PCT 16 P2 BW1
-0.98 TEC TEH 0.61 CBAY2 9
H 133 0
12 46 79 0.79 112 PCT 19 P2 VS3 0.9 TEC TEH 0.61 CBAY2 9
H 133 15 0
12 48 79 0.66 133 PCT 17 P2 VS3 1.04 TEC TEH 0.61 CBAY2 9
H 134 0
12 72 79 0.35 146 PCT 11 P2 BW1
-0.81 TEC TEH 0.61 CBAY2 5
H 56 0
12 76 79 0.61 99 PCT 16 P2 VS3
-0.88 TEC TEH 0.61 CBAY2 5
H 58 0
12 88 79 0.4 140 PCT 12 P2 BW1
-0.81 TEC TEH 0.61 CBAY2 11 H
104 0
12 116 79 0.35 141 PCT 11 P2 VS2
-0.69 VS3 TEH 0.61 CBAY2 39 H
40 0
12 130 79 0.2 102 PCT 7
P2 BW1
-0.75 VS3 TEH 0.61 CBAY2 39 H
41 0
12 150 79 0.35 52 PCT 11 P2 VS2
-0.85 VS3 TEH 0.61 CBAY2 101 H
10 0
12 156 79 0.35 87 PCT 11 P2 VS3
-0.91 VS3 TEC 0.61 CBAY2 290 C
193 0
12 164 79 0.35 88 PCT 11 P2 BW2 0.66 VS3 TEC 0.61 CBAY2 290 C
197 0
12 166 79 0.28 78 PCT 10 P2 BW1
-0.85 VS3 TEH 0.61 CBAY2 97 H
236 0
12 39 80 0.79 104 PCT 19 P2 BW2
-0.77 TEC TEH 0.61 CBAY2 9
H 153 6
12 43 80 0.6 45 PCT 16 P2 BW2
-1.21 TEC TEH 0.61 CBAY2 9
H 152 8
12 47 80 0.47 83 PCT 14 P2 VS3
-0.75 TEC TEH 0.61 CBAY2 9
H 150 0
12 49 80 0.3 69 PCT 10 P2 08H 0.81 TEC TEH 0.61 CBAY2 9
H 149 0
12 49 80 0.32 30 PCT 10 P2 BW1
-0.84 TEC TEH 0.61 CBAY2 9
H 149 0
12 51 80 0.34 146 PCT 11 P2 VS3
-0.8 TEC TEH 0.61 CBAY2 9
H 148 0
12 53 80 0.33 123 PCT 10 P2 09H 0.78 TEC TEH 0.61 CBAY2 9
H 147 0
12 87 80 1.22 266 PRX P8 09C 12.58 29.91 TEC TEH 0.61 CBAY2 9
H 95 0
12 87 80 0.56 190 BOW 119 09C 18.89 29.04 VS3 TEC 0.61 NYAX2 264 C
26 0
12 105 80 0.54 81 PCT 15 P2 VS3
-0.85 TEC TEH 0.61 CBAY2 9
H 104 0
12 137 80 0.36 139 PCT 11 P2 VS1
-0.7 VS3 TEH 0.61 CBAY2 39 H
47 0
12 153 80 0.26 68 PCT 10 P2 BW2 0.91 VS3 TEC 0.61 CBAY2 288 C
157 0
12 163 80 0.55 103 PCT 17 P2 BW2 0.8 VS3 TEC 0.61 CBAY2 46 C
85 0
12 165 80 0.27 103 PCT 9
P2 VS4 0.83 VS3 TEC 0.61 CBAY2 48 C
25 0
SG 12 Summary Data Sheets Page 9 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 34 81 0.3 100 PCT 10 P2 08C 0.8 TEC TEH 0.61 CBAY2 11 H
151 3
12 36 81 0.33 119 PCT 10 P2 BW1
-0.87 TEC TEH 0.61 CBAY2 11 H
152 4
12 38 81 0.55 141 PCT 15 P2 BW1
-0.75 TEC TEH 0.61 CBAY2 11 H
153 5
12 58 81 0.43 47 PCT 13 P2 BW1 0.98 TEC TEH 0.61 CBAY2 11 H
163 0
12 140 81 0.26 94 PCT 10 P2 VS3 1.23 VS3 TEC 0.61 CBAY2 288 C
140 0
12 154 81 0.32 132 PCT 10 P2 BW1
-0.95 VS3 TEH 0.61 CBAY2 95 H
314 0
12 162 81 0.56 86 PCT 17 P2 BW2 0.85 VS3 TEC 0.61 CBAY2 46 C
92 0
12 164 81 0.41 90 PCT 14 P2 BW2
-0.9 VS3 TEC 0.61 CBAY2 46 C
84 0
12 164 81 0.57 143 PCT 17 P2 BW2 0.77 VS3 TEC 0.61 CBAY2 46 C
84 0
12 168 81 0.39 113 PCT 13 P2 BW2
-0.92 VS3 TEC 0.61 CBAY2 48 C
68 0
12 55 82 0.44 101 PCT 13 P2 BW1
-1.66 TEC TEH 0.61 CBAY2 11 H
171 0
12 75 82 0.75 125 PCT 19 P2 VS2 0.49 TEC TEH 0.61 CBAY2 5
H 42 0
12 87 82 0.32 88 PCT 10 P2 BW1 0.92 TEC TEH 0.61 CBAY2 11 H
108 0
12 89 82 0.29 104 PCT 9
P2 BW1 1.05 TEC TEH 0.61 CBAY2 11 H
109 0
12 119 82 0.38 123 PCT 11 P2 VS3
-1.01 VS3 TEH 0.61 CBAY2 39 H
39 0
12 157 82 NDF P22 09H 34.7 11H TEH 0.61 NYAX2 61 H
13 0
12 163 82 0.32 99 PCT 11 P2 BW2
-0.9 VS3 TEC 0.61 CBAY2 46 C
93 0
12 163 82 NDF P31 09H 34.14 11H TEH 0.61 NYAX2 61 H
14 0
12 165 82 NDF P24 09H 34.09 11H TEH 0.61 NYAX2 61 H
7 0
12 44 83 0.38 126 PCT 11 P2 BW1
-0.87 TEC TEH 0.61 CBAY2 9
H 158 6
12 46 83 0.59 92 PCT 16 P2 BW2
-0.82 TEC TEH 0.61 CBAY2 9
H 159 7
12 48 83 0.32 138 PCT 10 P2 BW1
-1.1 TEC TEH 0.61 CBAY2 9
H 160 8
12 48 83 0.97 120 PCT 21 P2 09C
-0.99 TEC TEH 0.61 CBAY2 9
H 160 8
12 48 83 1.5 101 WAR 23 0.16 P3 09C
-0.74 09C TEC 0.61 NYAX2 264 C
24 F
0 12 52 83 0.59 104 PCT 16 P2 BW1
-0.79 TEC TEH 0.61 CBAY2 9
H 162 0
12 158 83 0.1 119 PCT 4
P2 BW1
-0.91 VS3 TEH 0.61 CBAY2 47 H
36 0
12 168 83 0.25 132 PCT 9
P2 VS5 0.78 VS3 TEC 0.61 CBAY2 48 C
28 0
12 168 83 0.37 80 PCT 12 P2 BW2
-0.86 VS3 TEC 0.61 CBAY2 48 C
28 0
12 39 84 0.51 76 PCT 14 P2 BW1
-0.82 TEC TEH 0.61 CBAY2 9
H 179 3
12 43 84 0.67 87 PCT 17 P2 BW1
-0.73 TEC TEH 0.61 CBAY2 9
H 178 5
12 45 84 0.75 66 PCT 18 P2 BW1
-0.81 TEC TEH 0.61 CBAY2 9
H 177 12 6
12 49 84 1.07 152 PCT 14 P2 08H 0.82 TEC TEH 0.61 CBAY2 9
H 176 8
12 49 84 0.51 112 PCT 14 P2 BW1 0.97 TEC TEH 0.61 CBAY2 9
H 176 8
12 55 84 0.37 89 PCT 11 P2 BW1
-0.52 TEC TEH 0.61 CBAY2 9
H 173 0
12 111 84 0.28 129 PCT 10 P2 BW1 0.96 VS3 TEH 0.61 CBAY2 45 H
88 0
12 111 84 2.23 265 PRX P8 10C 4.2 VS3 TEC 0.61 CBAY2 54 C
44 0
12 111 84 1
127 BOW 143 10C 6.29 17.94 VS3 TEC 0.61 NYAX2 264 C
27 0
12 121 84 0.38 113 PCT 11 P2 VS3
-1.05 VS3 TEH 0.61 CBAY2 39 H
38 0
12 123 84 0.24 53 PCT 10 P2 BW2 0.79 VS3 TEC 0.61 CBAY2 288 C
121 0
12 147 84 0.24 42 PCT 10 P2 BW2 0.83 VS3 TEC 0.61 CBAY2 288 C
109 0
12 163 84 0.52 113 PCT 15 P2 VS5 1.01 VS3 TEC 0.61 CBAY2 48 C
72 0
12 48 85 0.31 117 PCT 10 P2 09C
-0.4 TEC TEH 0.61 CBAY2 11 H
182 7
12 116 85 0.52 129 PCT 14 P2 BW1
-0.86 VS3 TEH 0.61 CBAY2 39 H
37 0
12 120 85 0.4 116 PCT 12 P2 VS1 0.66 VS3 TEH 0.61 CBAY2 91 H
345 0
12 132 85 0.11 110 PCT 4
P2 11H
-0.31 VS3 TEH 0.61 CBAY2 39 H
36 0
12 140 85 0.24 114 PCT 10 P2 VS3
-1.04 VS3 TEC 0.61 CBAY2 288 C
84 0
12 144 85 0.28 140 PCT 11 P2 BW2
-0.99 VS3 TEC 0.61 CBAY2 288 C
86 0
12 166 85 0.37 99 PCT 13 P2 BW2 0.82 VS3 TEC 0.61 CBAY2 288 C
97 0
SG 12 Summary Data Sheets Page 10 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 43 86 0.34 91 PCT 11 P2 BW2
-0.8 TEC TEH 0.61 CBAY2 11 H
198 4
12 53 86 0.37 123 PCT 11 P2 BW1
-0.71 TEC TEH 0.61 CBAY2 11 H
194 0
12 57 86 0.19 41 PCT 7
P2 VS3 1.04 TEC TEH 0.61 CBAY2 11 H
192 0
12 69 86 0.32 138 PCT 11 P2 VS3
-0.76 TEC TEH 0.61 CBAY2 5
H 12 0
12 93 86 0.33 108 PCT 10 P2 BW1
-0.66 TEC TEH 0.61 CBAY2 13 H
246 0
12 115 86 0.15 83 PCT 5
P2 BW2 0.74 VS3 TEC 0.61 CBAY2 254 C
101 0
12 117 86 0.41 121 PCT 12 P2 BW1
-0.81 VS3 TEH 0.61 CBAY2 39 H
33 0
12 119 86 0.49 123 PCT 14 P2 BW1 0.9 VS3 TEH 0.61 CBAY2 39 H
34 0
12 121 86 0.14 21 PCT 5
P2 BW2 0.74 VS3 TEC 0.61 CBAY2 254 C
104 0
12 125 86 0.36 119 PCT 11 P2 VS3
-0.5 VS3 TEH 0.61 CBAY2 91 H
367 0
12 151 86 0.13 14 PCT 4
P2 BW2 0.76 VS2 TEC 0.61 CBAY2 254 C
107 0
12 159 86 0.26 75 PCT 8
P2 BW2 0.75 VS2 TEC 0.61 CBAY2 254 C
108 0
12 161 86 0.52 112 PCT 14 P2 VS2 0.61 VS3 TEH 0.61 CBAY2 39 H
79 0
12 42 87 4.86 124 PRX P8 08C 10.96 35.22 TEC TEH 0.61 CBAY2 9
H 181 3
12 42 87 5.51 156 BOW 87 08C 14.34 30.73 VS3 TEC 0.61 NYAX2 264 C
25 0
12 44 87 1.13 120 PCT 23 P2 BW1 0.68 TEC TEH 0.61 CBAY2 9
H 182 4
12 44 87 1.26 106 PCT 25 P2 BW1 1.07 TEC TEH 0.61 CBAY2 9
H 182 4
12 44 87 0.35 95 PCT 11 P2 BW2
-0.9 TEC TEH 0.61 CBAY2 9
H 182 4
12 44 87 5.11 102 WAR 39 0.89 P22 BW1 0.66 VS3 TEH 0.61 NYAX2 59 H
50 T
4 12 90 87 0.26 54 PCT 8
P2 10H
-0.21 TEC TEH 0.61 CBAY2 13 H
255 0
12 114 87 0.39 109 PCT 11 P2 VS4
-0.71 VS3 TEC 0.61 CBAY2 254 C
106 0
12 118 87 0.43 96 PCT 12 P2 VS1 0.94 VS3 TEH 0.61 CBAY2 39 H
30 0
12 118 87 0.63 110 PCT 16 P2 VS3 0.96 VS3 TEH 0.61 CBAY2 39 H
30 0
12 166 87 0.34 87 PCT 11 P2 VS3
-0.95 VS3 TEC 0.61 CBAY2 290 C
91 0
12 49 88 1.68 101 PCT 28 P2 BW1 0.89 TEC TEH 0.61 CBAY2 9
H 197 6
12 49 88 2.79 128 WAR 30 0.17 P2 BW1 0.92 VS3 TEH 0.61 NYAX2 59 H
48 F
6 12 93 88 0.31 91 PCT 11 P2 BW1
-0.95 TEC TEH 0.61 CBAY2 25 H
70 0
12 125 88 0.85 109 PCT 20 P2 VS1 0.7 VS3 TEH 0.61 CBAY2 39 H
28 0
12 125 88 0.68 121 PCT 17 P2 VS3
-0.83 VS3 TEH 0.61 CBAY2 39 H
28 0
12 125 88 0.27 132 PCT 10 P2 VS4
-0.69 VS3 TEC 0.61 CBAY2 54 C
40 0
12 125 88 1.81 116 WAR 25 0.37 P23 VS1 0.83 VS3 TEH 0.61 NYAX2 57 H
51 T
0 12 125 88 1.78 92 WAR 25 0.43 P5 VS3
-0.6 VS3 TEH 0.61 NYAX2 57 H
51 T
0 12 133 88 0.62 152 PCT 11 P2 11H
-0.67 VS3 TEH 0.61 CBAY2 39 H
29 0
12 141 88 0.34 137 PCT 10 P2 VS1 0.63 VS3 TEH 0.61 CBAY2 39 H
49 0
12 145 88 0.29 119 PCT 11 P2 BW2 0.84 VS3 TEC 0.61 CBAY2 288 C
58 0
12 44 89 0.44 150 PCT 13 P2 BW1 1.24 TEC TEH 0.61 CBAY2 9
H 199 3
12 48 89 1.53 93 PCT 28 P2 BW1
-0.65 TEC TEH 0.61 CBAY2 11 H
200 5
12 48 89 0.82 95 PCT 20 P2 VS3
-1.06 TEC TEH 0.61 CBAY2 11 H
200 5
12 48 89 0.77 89 PCT 19 P2 09C
-1.24 TEC TEH 0.61 CBAY2 11 H
200 5
12 48 89 3.97 99 WAR 35 0.66 P6 BW1
-0.41 VS3 TEH 0.61 NYAX2 57 H
52 T
5 12 48 89 1.62 62 WAR 24 0.65 P21 BW1 0.84 VS3 TEH 0.61 NYAX2 57 H
52 T
5 12 48 89 0.84 107 WAR 18 P24 VS3
-0.89 VS3 TEH 0.61 NYAX2 57 H
52 5
12 50 89 0.38 116 PCT 12 P2 VS3 0.82 TEC TEH 0.61 CBAY2 11 H
201 6
12 140 89 0.31 103 PCT 10 P2 BW1 0.73 VS3 TEH 0.61 CBAY2 39 H
50 0
12 152 89 0.28 86 PCT 11 P2 VS3 1.24 VS3 TEC 0.61 CBAY2 288 C
37 0
12 158 89 0.32 106 PCT 12 P2 VS4
-0.77 VS3 TEC 0.61 CBAY2 288 C
40 0
12 160 89 0.52 117 PCT 14 P2 VS1 0.8 VS3 TEH 0.61 CBAY2 39 H
83 0
12 51 90 0.3 96 PCT 10 P2 BW1 0.99 TEC TEH 0.61 CBAY2 9
H 207 6
SG 12 Summary Data Sheets Page 11 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 51 90 0.2 115 PCT 7
P2 VS3 0.91 TEC TEH 0.61 CBAY2 9
H 207 6
12 53 90 0.39 37 PCT 12 P2 VS3
-1 TEC TEH 0.61 CBAY2 9
H 208 7
12 113 90 0.61 127 PCT 16 P2 VS2 0.63 VS3 TEH 0.61 CBAY2 39 H
27 0
12 113 90 0.32 105 PCT 12 P2 VS4 0.89 VS3 TEC 0.61 CBAY2 58 C
10 0
12 119 90 0.39 98 PCT 12 P2 VS2
-0.24 VS3 TEH 0.61 CBAY2 97 H
33 0
12 141 90 0
0 NQI P1 TEC 20.72 VS3 TEC 0.61 CBAY2 54 C
30 0
12 141 90 NDF P10 TEC 20.72 01C TEC 0.61 NYAX2 270 C
10 DQA 0
12 147 90 0.17 142 PCT 6
P2 03C
-0.8 VS2 TEC 0.61 CBAY2 254 C
111 0
12 157 90 0.22 141 PCT 7
P2 VS3
-0.97 VS3 TEH 0.61 CBAY2 39 H
84 0
12 50 91 0.53 126 PCT 15 P2 BW1 0.94 TEC TEH 0.61 CBAY2 9
H 201 5
12 60 91 0.31 56 PCT 10 P2 BW1 1.3 TEC TEH 0.61 CBAY2 9
H 206 0
12 66 91 0.3 125 PCT 10 P2 BW1
-0.88 TEC TEH 0.61 CBAY2 5
H 93 0
12 66 91 1.65 109 PCT 28 P2 VS3 1.33 TEC TEH 0.61 CBAY2 5
H 93 0
12 66 91 1.93 110 WAR 26 0.2 P7 VS3 1.38 VS3 TEH 0.61 NYAX2 57 H
53 F
0 12 124 91 0.24 122 PCT 8
P2 BW1
-0.94 VS3 TEH 0.61 CBAY2 39 H
26 0
12 134 91 0.18 112 PCT 7
P2 BW2
-1 VS3 TEC 0.61 CBAY2 54 C
38 0
12 144 91 0.14 102 PCT 5
P2 BW1
-0.91 VS3 TEH 0.61 CBAY2 39 H
54 0
12 148 91 0.12 103 PCT 4
P2 BW1
-0.81 VS3 TEH 0.61 CBAY2 39 H
53 0
12 162 91 0.15 110 PCT 5
P2 VS5 0.89 VS2 TEC 0.61 CBAY2 254 C
115 0
12 59 92 0.34 154 PCT 10 P2 BW2
-0.72 TEC TEH 0.61 CBAY2 13 H
6 0
12 77 92 0.79 128 PCT 19 P2 VS3
-0.81 TEC TEH 0.61 CBAY2 7
H 83 0
12 111 92 0.43 110 PCT 13 P2 BW1 1
TEC TEH 0.61 CBAY2 25 H
50 0
12 119 92 0.35 109 PCT 11 P2 BW1 0.48 VS3 TEH 0.61 CBAY2 95 H
67 0
12 112 93 0.57 142 PCT 16 P2 BW1
-1.24 VS3 TEH 0.61 CBAY2 97 H
36 8
0 12 114 93 0.49 105 PCT 14 P2 BW1 0.83 VS3 TEH 0.61 CBAY2 97 H
37 0
12 128 93 0.43 126 PCT 12 P2 VS4
-0.67 VS3 TEC 0.61 CBAY2 254 C
87 0
12 134 93 0.26 64 PCT 10 P2 BW2
-0.99 VS3 TEC 0.61 CBAY2 284 C
296 0
12 148 93 0.4 126 PCT 12 P2 VS3 0.9 VS3 TEH 0.61 CBAY2 39 H
56 0
12 150 93 0.36 113 PCT 13 P2 VS3 0.98 VS3 TEC 0.61 CBAY2 284 C
303 0
12 154 93 0.41 115 PCT 12 P2 VS3 1.08 VS3 TEH 0.61 CBAY2 39 H
86 0
12 160 93 0.41 135 PCT 12 P2 VS3 0.88 VS3 TEH 0.61 CBAY2 39 H
87 0
12 166 93 0.3 130 PCT 10 P2 11H 0.86 VS3 TEH 0.61 CBAY2 47 H
46 0
12 170 93 0.29 109 PCT 9
P2 BW2
-0.95 VS3 TEC 0.61 CBAY2 254 C
157 0
12 75 94 0.34 116 PCT 11 P2 VS2
-0.97 TEC TEH 0.61 CBAY2 5
H 103 0
12 89 94 5.73 97 PRX P8 09H 18.52 36.33 TEC TEH 0.61 CBAY2 27 H
36 0
12 89 94 NDF 108 09H 18.52 36.33 VS3 TEH 0.61 NYAX2 57 H
54 0
12 111 94 0.6 121 PCT 16 P2 VS3
-0.84 TEC TEH 0.61 CBAY2 27 H
47 0
12 141 94 0.31 137 PCT 10 P2 VS1
-0.78 VS3 TEH 0.61 CBAY2 39 H
58 0
12 145 94 0.23 99 PCT 8
P2 VS1 0.22 VS3 TEH 0.61 CBAY2 39 H
57 0
12 155 94 0.22 137 PCT 7
P2 VS3 0.87 VS3 TEH 0.61 CBAY2 39 H
90 0
12 157 94 0.26 87 PCT 10 P2 BW2 0.82 VS3 TEC 0.61 CBAY2 56 C
76 0
12 163 94 0.36 65 PCT 13 P2 VS5 0.27 VS3 TEC 0.61 CBAY2 56 C
71 0
12 165 94 0.39 111 PCT 12 P2 VS2
-0.73 VS3 TEH 0.61 CBAY2 101 H
23 0
12 171 94 0.24 118 PCT 9
P2 BW2
-0.9 VS3 TEC 0.61 CBAY2 56 C
56 0
12 52 95 0.56 102 PCT 15 P2 VS3
-0.94 TEC TEH 0.61 CBAY2 13 H
10 5
12 52 95 0.51 46 PCT 14 P2 BW2 0.34 TEC TEH 0.61 CBAY2 13 H
10 5
12 56 95 0.6 114 PCT 15 P2 VS3
-0.84 TEC TEH 0.61 CBAY2 13 H
12 7
12 84 95 0.31 114 NQI P1 TSH 0.31 TEC TEH 0.61 CBAY2 27 H
32 0
SG 12 Summary Data Sheets Page 12 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 84 95 NDF P6 TSH 0.31 01H TEH 0.61 NYAX2 57 H
57 0
12 132 95 0.58 94 PCT 17 P2 VS4 0.9 VS3 TEC 0.61 CBAY2 54 C
37 0
12 166 95 0.22 113 PCT 7
P2 VS5
-0.68 VS3 TEC 0.61 CBAY2 254 C
162 0
12 166 95 0.35 77 PCT 10 P2 BW2
-0.93 VS3 TEC 0.61 CBAY2 254 C
162 0
12 59 96 0.33 77 PCT 10 P2 BW1
-0.98 TEC TEH 0.61 CBAY2 13 H
18 8
12 63 96 0.32 26 PCT 10 P2 BW2
-0.91 TEC TEH 0.61 CBAY2 13 H
16 0
12 65 96 0.43 135 PCT 13 P2 VS4 0.8 TEC TEH 0.61 CBAY2 7
H 108 0
12 65 96 0.3 134 PCT 10 P2 08C
-0.76 TEC TEH 0.61 CBAY2 7
H 108 0
12 77 96 0.3 91 PCT 10 P2 09H 0.74 TEC TEH 0.61 CBAY2 7
H 102 0
12 145 96 0.25 127 PCT 10 P2 BW2
-1.05 VS3 TEC 0.61 CBAY2 284 C
266 0
12 155 96 0.32 140 PCT 10 P2 VS2 0.7 VS3 TEH 0.61 CBAY2 99 H
60 0
12 167 96 0.61 141 PCT 16 P2 BW2 0.83 VS3 TEC 0.61 CBAY2 254 C
154 0
12 54 97 0.64 104 PCT 16 P2 VS3
-0.87 TEC TEH 0.61 CBAY2 15 H
21 5
12 128 97 1.03 103 PCT 22 P2 VS3
-1.2 VS3 TEH 0.61 CBAY2 39 H
23 0
12 128 97 2.06 119 WAR 27 0.2 P30 VS3
-0.87 VS3 TEH 0.61 NYAX2 57 H
61 F
0 12 128 97 0.69 115 PCT 17 P2 VS4
-0.76 VS3 TEC 0.61 CBAY2 254 C
86 0
12 132 97 0.16 54 PCT 6
P2 VS1
-0.89 VS3 TEH 0.61 CBAY2 39 H
22 0
12 136 97 0.37 129 PCT 11 P2 BW2
-0.91 VS3 TEC 0.61 CBAY2 254 C
84 0
12 140 97 0.49 97 PCT 14 P2 BW1
-0.86 VS3 TEH 0.61 CBAY2 97 H
78 0
12 146 97 0.26 113 PCT 10 P2 BW2
-1.12 VS3 TEC 0.61 CBAY2 284 C
241 0
12 57 98 0.39 137 PCT 11 P2 BW1
-0.97 TEC TEH 0.61 CBAY2 15 H
27 7
12 61 98 0.46 99 PCT 12 P2 BW1
-0.89 TEC TEH 0.61 CBAY2 15 H
29 0
12 67 98 0.33 35 PCT 11 P2 BW1
-0.87 TEC TEH 0.61 CBAY2 5
H 126 0
12 75 98 0.83 129 PCT 20 P2 VS2 0.66 TEC TEH 0.61 CBAY2 5
H 122 0
12 75 98 1.08 83 WAR 20 0.34 P23 VS2 0.66 VS3 TEH 0.61 NYAX2 57 H
62 F
0 12 99 98 0.35 79 PCT 11 P2 BW2 0.87 TEC TEH 0.61 CBAY2 27 H
12 0
12 111 98 0.33 153 PCT 11 P2 VS4 0.9 TEC TEH 0.61 CBAY2 27 H
18 0
12 121 98 0.2 70 PCT 8
P2 VS4 0.93 VS3 TEC 0.61 CBAY2 54 C
36 0
12 127 98 0.56 58 PCT 17 P2 BW2 0.91 VS3 TEC 0.61 CBAY2 54 C
35 0
12 131 98 0.15 82 PCT 6
P2 BW2 0.9 VS3 TEC 0.61 CBAY2 54 C
34 0
12 135 98 0.35 103 PCT 11 P2 VS1
-0.89 VS3 TEH 0.61 CBAY2 39 H
61 0
12 145 98 0.33 84 PCT 12 P2 BW2 0.9 VS3 TEC 0.61 CBAY2 54 C
26 0
12 50 99 0.68 100 PCT 17 P2 BW1
-0.82 TEC TEH 0.61 CBAY2 13 H
33 3
12 50 99 0.49 96 PCT 13 P2 BW1 1.05 TEC TEH 0.61 CBAY2 13 H
33 3
12 50 99 0.74 123 PCT 18 P2 BW2 0.89 TEC TEH 0.61 CBAY2 13 H
33 3
12 74 99 0.74 148 PCT 12 P2 09H 0.66 TEC TEH 0.61 CBAY2 5
H 133 0
12 112 99 0.34 132 PCT 10 P2 BW1
-1.29 VS3 TEH 0.61 CBAY2 39 H
18 0
12 146 99 0.25 114 PCT 8
P2 VS2 0.67 VS3 TEH 0.61 CBAY2 39 H
62 0
12 150 99 0.52 115 PCT 16 P2 BW2
-0.87 VS3 TEC 0.61 CBAY2 54 C
24 0
12 170 99 0.31 58 PCT 9
P2 BW2
-1.01 VS3 TEC 0.61 CBAY2 254 C
149 0
12 49 100 0.36 88 PCT 11 P2 BW1
-0.96 TEC TEH 0.61 CBAY2 13 H
34 3
12 49 100 0.43 112 PCT 12 P2 BW1 1.05 TEC TEH 0.61 CBAY2 13 H
34 3
12 51 100 0.38 117 PCT 11 P2 BW1 0.94 TEC TEH 0.61 CBAY2 13 H
35 4
12 107 100 0.29 136 PCT 10 P2 BW1
-1.8 TEC TEH 0.61 CBAY2 21 H
223 0
12 111 100 0.51 131 PCT 15 P2 VS2 0.75 TEC TEH 0.61 CBAY2 21 H
225 0
0 12 113 100 0.29 124 PCT 10 P2 VS3 0.62 VS3 TEC 0.61 CBAY2 54 C
69 0
12 135 100 0.24 113 PCT 10 P2 BW2 0.87 VS3 TEC 0.61 CBAY2 284 C
220 0
12 155 100 0.3 69 PCT 10 P2 VS2 0.8 VS3 TEH 0.61 CBAY2 101 H
102 0
SG 12 Summary Data Sheets Page 13 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 155 100 0.43 69 PCT 15 P2 BW2 1.03 VS3 TEC 0.61 CBAY2 284 C
210 10 0
12 159 100 0.4 104 PCT 14 P2 BW2 0.91 VS3 TEC 0.61 CBAY2 284 C
208 0
12 169 100 0.46 127 PCT 13 P2 BW2 0.8 VS3 TEC 0.61 CBAY2 254 C
150 0
12 171 100 0.44 128 PCT 11 P2 11H 0.73 VS3 TEH 0.61 CBAY2 45 H
64 0
12 60 101 0.69 104 PCT 16 P2 BW1
-0.84 TEC TEH 0.61 CBAY2 15 H
32 8
12 60 101 0.52 129 PCT 14 P2 VS3
-0.88 TEC TEH 0.61 CBAY2 15 H
32 8
12 106 101 0.32 118 PCT 11 P2 VS4
-0.86 TEC TEH 0.61 CBAY2 21 H
198 0
12 108 101 0.3 142 PCT 10 P2 BW1 1.77 TEC TEH 0.61 CBAY2 21 H
197 0
12 126 101 0.37 103 PCT 12 P2 VS2 0.74 VS3 TEH 0.61 CBAY2 97 H
100 0
12 142 101 0.61 119 PCT 16 P2 VS1 0.73 VS3 TEH 0.61 CBAY2 39 H
65 0
12 144 101 0.62 104 PCT 16 P2 VS3 0.8 VS3 TEH 0.61 CBAY2 39 H
64 0
12 166 101 0.66 114 PCT 17 P2 VS2
-0.76 VS3 TEH 0.61 CBAY2 47 H
63 0
12 166 101 1.47 116 PCT 30 P2 VS3 0.73 VS3 TEC 0.61 CBAY2 56 C
50 0
12 166 101 0.54 109 PCT 17 P2 BW2
-0.95 VS3 TEC 0.61 CBAY2 56 C
50 0
12 166 101 2.71 95 WAR 30 0.45 P31 VS3 1.02 VS3 TEH 0.61 NYAX2 61 H
6 T
0 12 53 102 0.71 86 PCT 18 P2 VS3
-1.03 TEC TEH 0.61 CBAY2 23 H
211 4
12 55 102 0.42 114 PCT 12 P2 VS3
-1.14 TEC TEH 0.61 CBAY2 15 H
39 5
12 57 102 0.34 142 PCT 10 P2 BW2
-1.82 TEC TEH 0.61 CBAY2 15 H
40 6
12 59 102 0.33 136 PCT 11 P2 BW2
-0.71 TEC TEH 0.61 CBAY2 23 H
212 7
12 63 102 0.69 119 PCT 16 P2 VS3
-1 TEC TEH 0.61 CBAY2 15 H
43 0
12 67 102 0.34 97 PCT 11 P2 BW1 0.36 TEC TEH 0.61 CBAY2 5
H 145 0
12 67 102 0.47 68 PCT 14 P2 VS4 0.95 TEC TEH 0.61 CBAY2 5
H 145 0
12 69 102 0.44 57 PCT 13 P2 BW2
-0.91 TEC TEH 0.61 CBAY2 5
H 144 0
12 101 102 0.44 115 PCT 13 P2 VS2
-1 TEC TEH 0.61 CBAY2 23 H
222 0
12 101 102 0.62 100 PCT 17 P2 VS3
-1.06 TEC TEH 0.61 CBAY2 23 H
222 0
12 101 102 0.33 123 PCT 11 P2 VS4 0.38 TEC TEH 0.61 CBAY2 23 H
222 0
12 101 102 1.8 108 PCT 30 P2 VS4 1.07 TEC TEH 0.61 CBAY2 23 H
222 0
12 101 102 2.82 102 WAR 30 0.14 P2 VS4 1.05 VS3 TEC 0.61 NYAX2 264 C
56 F
0 12 159 102 0.32 32 PCT 10 P2 BW2 0.71 VS3 TEC 0.61 CBAY2 286 C
213 0
12 66 103 0.34 121 PCT 11 P2 VS3
-0.74 TEC TEH 0.61 CBAY2 5
H 148 0
12 72 103 0.52 140 PCT 15 P2 VS2
-0.82 TEC TEH 0.61 CBAY2 5
H 151 0
12 72 103 0.49 86 PCT 14 P2 VS4
-0.84 TEC TEH 0.61 CBAY2 5
H 151 0
12 86 103 0.26 125 PCT 9
P2 BW1
-0.89 TEC TEH 0.61 CBAY2 23 H
209 0
12 138 103 3.69 181 DNT P1 10C 25.6 VS3 TEC 0.61 CBAY2 54 C
5 0
12 146 103 0.31 129 PCT 10 P2 VS3 0.71 VS3 TEH 0.61 CBAY2 45 H
83 0
12 150 103 0.37 119 PCT 11 P2 VS3 0.98 VS3 TEH 0.61 CBAY2 39 H
66 0
12 152 103 0.29 85 PCT 10 P2 BW2
-0.91 VS3 TEC 0.61 CBAY2 286 C
200 0
12 162 103 0.15 30 PCT 6
P2 VS4 0.91 VS3 TEC 0.61 CBAY2 56 C
62 0
12 166 103 0.87 79 PCT 20 P2 BW2
-0.9 VS3 TEC 0.61 CBAY2 254 C
152 0
12 166 103 1.55 99 WAR 23 0.22 P1 BW2
-0.87 VS3 TEC 0.61 NYAX2 274 C
11 F
0 12 53 104 0.61 123 PCT 15 P2 BW1 1.02 TEC TEH 0.61 CBAY2 13 H
50 5
12 77 104 0.73 137 PCT 15 P2 09H 0.72 TEC TEH 0.61 CBAY2 7
H 143 0
12 83 104 0.32 123 PCT 11 P2 VS2 0.69 TEC TEH 0.61 CBAY2 21 H
179 0
12 105 104 1.06 94 PLP 8
08H 2.71 TEC TEH 0.61 CBAY2 21 H
190 HR 0
12 105 104 9.62 111 PLP 156 08H 2.64 10H TEH 0.61 NYAX2 57 H
81 HR 0
12 107 104 0.37 118 PCT 12 P2 BW1 1.42 TEC TEH 0.61 CBAY2 21 H
191 0
12 119 104 0.25 98 PCT 10 P2 VS4 0.89 VS3 TEC 0.61 CBAY2 284 C
173 0
12 135 104 0.32 129 PCT 12 P2 BW2 0.85 VS3 TEC 0.61 CBAY2 284 C
165 0
SG 12 Summary Data Sheets Page 14 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 157 104 0.27 93 PCT 10 P2 BW2 0.8 VS3 TEC 0.61 CBAY2 284 C
158 0
12 50 105 0.32 124 PCT 9
P2 VS3 0.9 TEC TEH 0.61 CBAY2 15 H
50 3
12 60 105 0.27 136 PCT 8
P2 VS2 0.9 TEC TEH 0.61 CBAY2 15 H
45 8
12 60 105 0.39 133 PCT 11 P2 BW2 0.96 TEC TEH 0.61 CBAY2 15 H
45 8
12 150 105 0.27 80 PCT 8
P2 BW2
-0.83 VS3 TEC 0.61 CBAY2 254 C
119 0
12 158 105 0.36 115 PCT 11 P2 BW2 0.77 VS3 TEC 0.61 CBAY2 254 C
118 0
12 164 105 0.32 48 PCT 12 P2 BW2
-0.96 VS3 TEC 0.61 CBAY2 284 C
149 0
12 166 105 0.91 139 PCT 20 P2 BW2
-0.86 VS3 TEC 0.61 CBAY2 254 C
142 0
12 166 105 1.49 100 WAR 23 0.22 P2 BW2
-0.87 VS3 TEC 0.61 NYAX2 274 C
12 F
0 12 170 105 0.36 144 PCT 11 P2 11H 0.78 VS3 TEH 0.61 CBAY2 45 H
70 0
12 170 105 0.64 119 PCT 17 P2 VS1 0.8 VS3 TEH 0.61 CBAY2 45 H
70 0
12 49 106 0.57 118 PCT 15 P2 BW1
-1.01 TEC TEH 0.61 CBAY2 13 H
63 3
12 51 106 0.39 139 PCT 11 P2 BW1
-0.24 TEC TEH 0.61 CBAY2 13 H
80 4
12 51 106 1.66 86 PCT 28 P2 BW1 0.48 TEC TEH 0.61 CBAY2 13 H
80 4
12 51 106 2.83 112 WAR 30 0.2 P20 BW1 0.89 VS3 TEH 0.61 NYAX2 59 H
10 F
4 12 61 106 0.7 113 PCT 17 P2 VS3 0.65 TEC TEH 0.61 CBAY2 13 H
85 0
12 67 106 0.51 99 PCT 14 P2 VS3
-0.92 TEC TEH 0.61 CBAY2 5
H 164 0
12 75 106 0.3 63 PCT 10 P2 BW1 0.92 TEC TEH 0.61 CBAY2 5
H 160 0
12 77 106 1.07 115 PCT 23 P2 VS3
-0.81 TEC TEH 0.61 CBAY2 5
H 159 0
12 77 106 1.35 111 WAR 22 0.17 P7 VS3
-0.88 VS3 TEH 0.61 NYAX2 59 H
9 F
0 12 97 106 0.37 133 PCT 12 P2 BW1 0.92 TEC TEH 0.61 CBAY2 23 H
188 0
12 107 106 0.5 129 PCT 14 P2 BW1 1.9 TEC TEH 0.61 CBAY2 23 H
193 0
12 139 106 0.34 119 PCT 11 P2 VS1
-0.94 VS3 TEH 0.61 CBAY2 97 H
139 0
12 50 107 0.39 134 PCT 11 P2 BW1
-0.83 TEC TEH 0.61 CBAY2 13 H
62 3
12 50 107 0.53 102 PCT 14 P2 BW1 1.08 TEC TEH 0.61 CBAY2 13 H
62 3
12 60 107 0.48 33 PCT 13 P2 VS2 1.11 TEC TEH 0.61 CBAY2 13 H
57 8
12 114 107 0.32 143 PCT 10 P2 BW1 0.93 VS3 TEH 0.61 CBAY2 95 H
160 0
12 128 107 0.45 139 PCT 13 P2 VS1
-0.72 VS3 TEH 0.61 CBAY2 39 H
16 0
12 130 107 1.24 111 PCT 24 P2 VS2 0.78 VS3 TEH 0.61 CBAY2 39 H
15 0
12 130 107 2.58 108 WAR 29 0.83 P30 VS2 0.78 VS3 TEH 0.61 NYAX2 59 H
5 T
0 12 168 107 0.3 110 PCT 10 P2 BW1
-0.91 VS3 TEH 0.61 CBAY2 47 H
73 0
12 49 108 0.59 132 PCT 13 P2 09H
-1.38 TEC TEH 0.61 CBAY2 13 H
64 3
12 49 108 0.55 129 PCT 15 P2 BW2
-0.74 TEC TEH 0.61 CBAY2 13 H
64 3
12 53 108 0.4 130 PCT 12 P2 BW1
-0.79 TEC TEH 0.61 CBAY2 13 H
65 5
12 75 108 0.4 123 PCT 12 P2 VS4
-0.59 TEC TEH 0.61 CBAY2 7
H 163 0
12 87 108 2.25 108 PCT 33 P2 VS4
-1.03 TEC TEH 0.61 CBAY2 21 H
152 0
12 87 108 1.32 104 PCT 26 P2 VS4
-0.65 TEC TEH 0.61 CBAY2 21 H
152 0
12 87 108 2.71 109 WAR 30 0.88 P26 VS4
-1.15 VS3 TEC 0.61 NYAX2 264 C
58 T
0 12 93 108 0.37 142 PCT 12 P2 VS2 0.62 TEC TEH 0.61 CBAY2 21 H
155 0
12 93 108 0.29 98 PCT 10 P2 VS3
-0.9 TEC TEH 0.61 CBAY2 21 H
155 0
12 107 108 0.37 119 PCT 12 P2 VS2 0.77 TEC TEH 0.61 CBAY2 21 H
162 0
12 115 108 0.53 124 PCT 14 P2 VS2 0.75 VS3 TEH 0.61 CBAY2 39 H
14 0
12 145 108 0.41 31 PCT 12 P2 BW2 0.82 VS3 TEC 0.61 CBAY2 252 C
78 0
12 169 108 0.4 133 PCT 12 P2 BW2 0.91 VS3 TEC 0.61 CBAY2 254 C
137 0
12 171 108 0.29 121 PCT 9
P2 BW2 0.78 VS3 TEC 0.61 CBAY2 254 C
134 0
12 54 109 0.33 38 PCT 10 P2 BW2
-1.17 TEC TEH 0.61 CBAY2 13 H
75 6
12 70 109 0.3 122 PCT 10 P2 VS3 0.84 TEC TEH 0.61 CBAY2 11 H
13 0
12 104 109 0.45 141 PCT 14 P2 BW1
-0.87 TEC TEH 0.61 CBAY2 21 H
139 0
SG 12 Summary Data Sheets Page 15 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 120 109 0.39 146 PCT 12 P2 BW1 0.76 VS3 TEH 0.61 CBAY2 39 H
13 0
12 120 109 0.58 120 PCT 15 P2 VS3 0.7 VS3 TEH 0.61 CBAY2 39 H
13 0
12 126 109 0.5 111 PCT 14 P2 VS3 0.73 VS3 TEC 0.61 CBAY2 252 C
81 0
12 128 109 0.34 88 PCT 11 P2 VS3 0.85 VS3 TEC 0.61 CBAY2 252 C
80 0
12 132 109 0.37 88 PCT 12 P2 VS1
-0.96 VS3 TEH 0.61 CBAY2 97 H
160 0
12 146 109 0.34 114 PCT 11 P2 VS2 0.8 VS3 TEH 0.61 CBAY2 101 H
200 0
12 152 109 0.47 78 PCT 14 P2 BW2
-0.93 VS3 TEC 0.61 CBAY2 252 C
79 0
12 154 109 0.3 57 PCT 10 P2 VS1 0.81 VS3 TEH 0.61 CBAY2 101 H
171 0
12 166 109 0.78 85 PCT 21 P2 BW2
-0.95 VS3 TEC 0.61 CBAY2 56 C
38 0
12 166 109 1.51 97 WAR 23 0.24 P2 BW2
-0.87 VS3 TEC 0.61 NYAX2 274 C
13 F
0 12 170 109 0.64 152 PCT 11 P2 11C 0.77 VS3 TEC 0.61 CBAY2 284 C
101 0
12 49 110 0.48 96 PCT 13 P2 BW1
-0.99 TEC TEH 0.61 CBAY2 13 H
78 3
12 49 110 2.26 90 PCT 32 P2 BW2
-0.83 TEC TEH 0.61 CBAY2 13 H
78 0
3 12 49 110 2.99 120 WAR 31 0.17 P27 BW2
-0.91 VS3 TEC 0.61 NYAX2 264 C
64 F
0 12 59 110 0.6 76 PCT 15 P2 BW1 0.81 TEC TEH 0.61 CBAY2 13 H
89 8
12 61 110 0.48 76 PCT 13 P2 BW1 0.84 TEC TEH 0.61 CBAY2 13 H
88 0
12 65 110 0.33 135 PCT 10 P2 VS4 1.06 TEC TEH 0.61 CBAY2 9
H 16 0
12 69 110 1.33 101 PCT 25 P2 VS4 1.02 TEC TEH 0.61 CBAY2 9
H 18 0
0 12 69 110 1.44 126 WAR 23 0.14 P14 VS4 1.49 VS3 TEC 0.61 NYAX2 264 C
63 F
0 12 89 110 0.41 63 PCT 13 P2 BW1 0.9 TEC TEH 0.61 CBAY2 23 H
155 0
12 99 110 0.21 155 PCT 7
P2 VS2 0.82 TEC TEH 0.61 CBAY2 23 H
160 0
12 113 110 8.04 177 DNT P1 10C 23.7 VS3 TEC 0.61 CBAY2 54 C
70 0
12 113 110 NDF P46 10C 24.57 VS3 TEC 0.61 NYAX2 264 C
57 0
12 167 110 0.32 143 PCT 10 P2 VS3 0.68 VS3 TEC 0.61 CBAY2 254 C
139 0
12 167 110 0.51 141 PCT 14 P2 BW2 0.72 VS3 TEC 0.61 CBAY2 254 C
139 0
12 169 110 0.47 135 PCT 11 P2 11C 0.92 VS3 TEC 0.61 CBAY2 286 C
103 0
12 50 111 0.48 90 PCT 13 P2 BW2 0.91 TEC TEH 0.61 CBAY2 13 H
93 4
12 68 111 0.77 103 PCT 19 P2 VS4
-0.94 TEC TEH 0.61 CBAY2 9
H 32 0
12 88 111 0.52 94 PCT 15 P2 BW1
-0.81 TEC TEH 0.61 CBAY2 23 H
149 0
12 108 111 0.63 137 PCT 17 P2 VS2
-0.94 TEC TEH 0.61 CBAY2 23 H
139 0
12 112 111 0.39 130 PCT 11 P2 BW1
-0.85 VS3 TEH 0.61 CBAY2 39 H
10 0
12 150 111 0.46 65 PCT 13 P2 BW2
-0.91 VS3 TEC 0.61 CBAY2 252 C
84 0
12 162 111 0.32 95 PCT 10 P2 BW2
-0.94 VS3 TEC 0.61 CBAY2 286 C
97 0
12 170 111 0.35 116 PCT 11 P2 BW2 0.76 VS3 TEC 0.61 CBAY2 286 C
101 0
12 47 112 0.38 109 PCT 11 P2 VS3
-0.34 TEC TEH 0.61 CBAY2 13 H
108 3
12 47 112 0.32 143 PCT 10 P2 VS3 0.68 TEC TEH 0.61 CBAY2 13 H
108 3
12 47 112 0.61 58 PCT 15 P2 BW2 0.37 TEC TEH 0.61 CBAY2 13 H
108 3
12 47 112 0.34 55 PCT 10 P2 08C
-0.83 TEC TEH 0.61 CBAY2 13 H
108 3
12 49 112 1.22 118 PCT 24 P2 BW1 0.55 TEC TEH 0.61 CBAY2 13 H
107 4
12 49 112 1.96 126 WAR 26 0.17 P19 BW1 0.72 VS3 TEH 0.61 NYAX2 59 H
16 F
4 12 59 112 0.38 99 PCT 11 P2 BW1 0.96 TEC TEH 0.61 CBAY2 13 H
102 0
12 155 112 0.32 90 PCT 12 P2 BW2 0.78 VS3 TEC 0.61 CBAY2 284 C
66 0
12 161 112 0.15 147 PCT 6
P2 VS4 0.75 VS3 TEC 0.61 CBAY2 56 C
49 0
12 169 112 0.34 134 PCT 12 P2 BW2 0.79 VS3 TEC 0.61 CBAY2 284 C
60 0
12 70 113 0.35 131 PCT 11 P2 VS4
-0.84 TEC TEH 0.61 CBAY2 11 H
32 0
12 102 113 0.52 128 PCT 15 P2 VS4
-0.83 TEC TEH 0.61 CBAY2 21 H
111 0
12 108 113 0.36 99 PCT 12 P2 VS2 0.8 TEC TEH 0.61 CBAY2 21 H
108 0
12 112 113 0.38 110 PCT 11 P2 BW1
-1 TEC TEH 0.61 CBAY2 37 H
101 0
SG 12 Summary Data Sheets Page 16 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 136 113 0.22 89 PCT 7
P2 BW1
-0.92 VS3 TEH 0.61 CBAY2 39 H
95 0
12 150 113 0.24 155 PCT 8
P2 VS1 0.78 VS3 TEH 0.61 CBAY2 39 H
96 0
12 150 113 0.21 37 PCT 7
P2 BW2
-0.97 VS3 TEC 0.61 CBAY2 252 C
85 0
12 168 113 0.27 102 PCT 9
P2 BW1
-0.88 VS3 TEH 0.61 CBAY2 47 H
83 0
12 49 114 1.06 66 PCT 22 P2 BW2
-0.72 TEC TEH 0.61 CBAY2 13 H
123 5
12 49 114 1.27 92 WAR 21 0.19 P11 BW2
-0.79 VS3 TEC 0.61 NYAX2 264 C
66 T
0 12 61 114 0.53 87 PCT 14 P2 VS2
-0.94 TEC TEH 0.61 CBAY2 13 H
117 0
12 85 114 0.44 116 PCT 13 P2 VS2 0.92 TEC TEH 0.61 CBAY2 23 H
124 0
12 89 114 0.22 64 PCT 8
P2 BW1 0.75 TEC TEH 0.61 CBAY2 23 H
126 0
12 89 114 1.44 114 PCT 27 P2 VS3
-0.84 TEC TEH 0.61 CBAY2 23 H
126 0
12 89 114 1.12 84 WAR 20 0.22 P2 BW1 0.86 VS3 TEH 0.61 NYAX2 59 H
22 T
0 12 89 114 2.97 103 WAR 31 0.65 P6 VS3
-0.59 VS3 TEH 0.61 NYAX2 59 H
22 T
0 12 95 114 0.38 151 PCT 12 P2 BW1
-0.97 TEC TEH 0.61 CBAY2 23 H
129 0
12 151 114 0.26 133 PCT 8
P2 VS1
-0.86 VS3 TEH 0.61 CBAY2 39 H
98 0
12 151 114 0.24 52 PCT 8
P2 BW2 0.82 VS3 TEC 0.61 CBAY2 252 C
88 0
12 155 114 0.37 59 PCT 11 P2 BW2 0.77 VS3 TEC 0.61 CBAY2 252 C
89 0
12 48 115 0.39 39 PCT 11 P2 BW1
-0.73 TEC TEH 0.61 CBAY2 13 H
124 5
12 48 115 0.33 77 PCT 10 P2 VS3 0.78 TEC TEH 0.61 CBAY2 13 H
124 5
12 48 115 1.53 128 PCT 24 P2 09C
-1.31 TEC TEH 0.61 CBAY2 13 H
124 5
12 48 115 0.72 71 WAR 16 0.16 P24 09C
-1.16 09C TEC 0.61 NYAX2 274 C
49 F
5 12 52 115 0.27 55 PCT 9
P2 BW2 0.92 TEC TEH 0.61 CBAY2 13 H
126 7
12 58 115 0.31 129 PCT 10 P2 BW1 1.02 TEC TEH 0.61 CBAY2 13 H
129 0
12 64 115 2.78 96 LNI P5 TSC
-0.02 TEC TEH 0.61 CBAY2 9
H 53 0
12 64 115 NDF P33 TSC
-0.02 01C TEC 0.61 NYAX2 264 C
65 0
12 118 115 0.27 120 PCT 10 P2 VS3 1
VS3 TEC 0.61 CBAY2 58 C
7 0
12 144 115 0.33 126 PCT 10 P2 VS1
-0.87 VS3 TEH 0.61 CBAY2 101 H
231 0
12 160 115 0.32 92 PCT 10 P2 BW2
-1.05 VS3 TEC 0.61 CBAY2 286 C
66 0
12 166 115 0.58 109 PCT 17 P2 BW2
-0.86 VS3 TEC 0.61 CBAY2 56 C
22 0
12 168 115 1.28 116 PCT 25 P2 BW2
-0.86 VS3 TEC 0.61 CBAY2 254 C
122 0
12 168 115 2.33 103 WAR 28 0.15 P25 BW2
-0.56 VS3 TEC 0.61 NYAX2 264 C
94 F
0 12 43 116 0.65 81 PCT 16 P2 BW1
-0.91 TEC TEH 0.61 CBAY2 13 H
142 3
12 43 116 0.54 137 PCT 14 P2 BW1
-0.27 TEC TEH 0.61 CBAY2 13 H
142 3
12 43 116 0.55 137 PCT 14 P2 BW1 0.78 TEC TEH 0.61 CBAY2 13 H
142 3
12 43 116 0.33 141 PCT 10 P2 BW2
-0.75 TEC TEH 0.61 CBAY2 13 H
142 3
12 47 116 0.45 87 PCT 13 P2 VS3
-0.84 TEC TEH 0.61 CBAY2 13 H
140 5
12 47 116 0.52 60 PCT 14 P2 BW2
-1.31 TEC TEH 0.61 CBAY2 13 H
140 5
12 47 116 1.47 104 PCT 26 P2 BW2 0.63 TEC TEH 0.61 CBAY2 13 H
140 5
12 47 116 1.36 99 WAR 22 0.35 P10 BW2 0.63 VS3 TEC 0.61 NYAX2 264 C
68 T
0 12 51 116 0.41 121 PCT 12 P2 BW1 0.88 TEC TEH 0.61 CBAY2 13 H
139 7
12 87 116 0.33 110 PCT 11 P2 BW1 0.82 TEC TEH 0.61 CBAY2 21 H
94 0
12 89 116 0.29 89 PCT 10 P2 BW2 0.9 TEC TEH 0.61 CBAY2 21 H
95 0
12 107 116 0.34 135 PCT 11 P2 BW1
-1.35 TEC TEH 0.61 CBAY2 21 H
104 0
12 107 116 0.35 107 PCT 12 P2 BW1 1.68 TEC TEH 0.61 CBAY2 21 H
104 0
12 149 116 0.3 68 PCT 10 P2 BW2 0.88 VS3 TEC 0.61 CBAY2 252 C
92 0
12 153 116 0.34 43 PCT 11 P2 BW2 0.78 VS3 TEC 0.61 CBAY2 252 C
91 0
12 155 116 0.18 99 PCT 7
P2 BW2 0.83 VS3 TEC 0.61 CBAY2 252 C
90 0
12 165 116 0.37 59 PCT 13 P2 VS5 0.93 VS3 TEC 0.61 CBAY2 56 C
21 0
12 167 116 0.35 143 PCT 10 P2 BW2 0.13 VS3 TEC 0.61 CBAY2 254 C
121 0
SG 12 Summary Data Sheets Page 17 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 167 116 0.58 107 PCT 15 P2 BW2 0.79 VS3 TEC 0.61 CBAY2 254 C
121 0
12 169 116 0.22 133 PCT 7
P2 VS5 0.88 VS3 TEC 0.61 CBAY2 254 C
126 0
12 44 117 0.36 128 PCT 11 P2 BW1
-0.38 TEC TEH 0.61 CBAY2 13 H
143 4
12 44 117 0.73 96 PCT 18 P2 BW2
-0.88 TEC TEH 0.61 CBAY2 13 H
143 4
12 46 117 0.39 113 PCT 11 P2 VS3 0.85 TEC TEH 0.61 CBAY2 13 H
144 5
12 46 117 0.33 91 PCT 10 P2 BW2 0.89 TEC TEH 0.61 CBAY2 13 H
144 5
12 48 117 0.44 88 PCT 12 P2 VS3 0.83 TEC TEH 0.61 CBAY2 13 H
145 6
12 54 117 0.35 131 PCT 11 P2 VS3
-1.05 TEC TEH 0.61 CBAY2 13 H
148 0
12 58 117 0.65 74 PCT 16 P2 VS2 0.94 TEC TEH 0.61 CBAY2 13 H
150 0
12 82 117 0.3 96 PCT 10 P2 BW1
-0.77 TEC TEH 0.61 CBAY2 11 H
47 0
12 84 117 0.27 84 PCT 10 P2 05C
-0.74 TEC TEH 0.61 CBAY2 21 H
91 0
12 88 117 0.3 106 PCT 10 P2 BW1 0.9 TEC TEH 0.61 CBAY2 21 H
89 0
12 130 117 0.63 128 PCT 16 P2 BW2
-0.8 TEC TEH 0.61 CBAY2 37 H
48 0
12 138 117 0.29 123 PCT 9
P2 BW1
-0.83 VS3 TEH 0.61 CBAY2 39 H
104 0
12 154 117 0.48 81 PCT 14 P2 VS3 0.75 VS3 TEC 0.61 CBAY2 252 C
93 0
12 160 117 0.29 86 PCT 10 P2 BW2
-0.92 VS3 TEC 0.61 CBAY2 252 C
112 0
12 164 117 0.25 97 PCT 10 P2 VS4
-0.76 VS3 TEC 0.61 CBAY2 284 C
34 0
12 166 117 0.64 124 PCT 17 P2 VS1
-0.78 VS3 TEH 0.61 CBAY2 47 H
111 0
12 168 117 0.17 80 PCT 6
P2 VS3 0.89 VS3 TEC 0.61 CBAY2 254 C
83 0
12 45 118 0.35 81 PCT 10 P2 BW1
-0.95 TEC TEH 0.61 CBAY2 13 H
162 5
12 45 118 1.26 109 PCT 24 P2 BW1 1.05 TEC TEH 0.61 CBAY2 13 H
162 5
12 45 118 1.9 117 WAR 26 0.17 P19 BW1 0.92 VS3 TEH 0.61 NYAX2 59 H
24 F
5 12 47 118 0.81 118 PCT 19 P2 BW1 1.08 TEC TEH 0.61 CBAY2 13 H
161 6
12 47 118 4.37 305 PRX P8 08C 26.45 35.31 TEC TEH 0.61 CBAY2 13 H
161 6
12 47 118 4.56 22 BOW 23 08C 30.72 34.74 VS3 TEC 0.61 NYAX2 264 C
70 0
12 49 118 0.54 79 PCT 14 P2 BW1 0.99 TEC TEH 0.61 CBAY2 13 H
160 7
12 53 118 0.74 97 PCT 18 P2 VS3 0.77 TEC TEH 0.61 CBAY2 13 H
158 0
12 57 118 0.35 123 PCT 10 P2 BW1
-0.14 TEC TEH 0.61 CBAY2 13 H
156 0
12 61 118 0.61 110 PCT 16 P2 VS2
-0.88 TEC TEH 0.61 CBAY2 13 H
154 0
12 63 118 0.45 145 PCT 13 P2 VS2
-0.93 TEC TEH 0.61 CBAY2 13 H
153 0
12 65 118 0.31 77 PCT 10 P2 VS3
-0.89 TEC TEH 0.61 CBAY2 9
H 63 0
12 79 118 3.61 312 LNI P7 TSH 0.15 TEC TEH 0.61 CBAY2 9
H 56 0
12 79 118 NDF 121 TSH 0.15 01H TEH 0.61 NYAX2 59 H
23 0
12 85 118 0.41 116 PCT 12 P2 BW1
-0.97 TEC TEH 0.61 CBAY2 23 H
95 0
12 89 118 0.32 133 PCT 11 P2 BW1
-0.91 TEC TEH 0.61 CBAY2 23 H
97 0
12 119 118 0.33 117 PCT 10 P2 BW1 0.91 TEC TEH 0.61 CBAY2 37 H
40 0
12 131 118 0.33 102 PCT 10 P2 BW2 0.43 TEC TEH 0.61 CBAY2 29 H
24 0
12 139 118 0.23 44 PCT 8
P2 BW2 0.78 VS3 TEC 0.61 CBAY2 252 C
70 0
12 141 118 0.37 140 PCT 11 P2 VS1
-0.73 VS3 TEH 0.61 CBAY2 39 H
108 0
12 141 118 0.35 45 PCT 11 P2 BW2 0.81 VS3 TEC 0.61 CBAY2 252 C
95 0
12 143 118 0.51 117 PCT 14 P2 VS1
-0.85 VS3 TEH 0.61 CBAY2 39 H
107 0
12 163 118 0.37 73 PCT 13 P2 BW2 0.86 VS3 TEC 0.61 CBAY2 56 C
19 0
12 44 119 0.6 125 PCT 15 P2 BW1 1.07 TEC TEH 0.61 CBAY2 13 H
163 5
12 46 119 0.79 112 PCT 18 P2 BW1 1.02 TEC TEH 0.61 CBAY2 13 H
164 13 6
12 48 119 0.38 105 PCT 11 P2 BW1 1.04 TEC TEH 0.61 CBAY2 13 H
165 7
12 60 119 0.41 105 PCT 12 P2 VS2 1.06 TEC TEH 0.61 CBAY2 13 H
171 0
12 80 119 2.61 254 LNI P7 TSH
-0.07 TEC TEH 0.61 CBAY2 11 H
67 0
12 80 119 NDF P5 TSH
-0.07 01H TEH 0.61 NYAX2 59 H
29 0
SG 12 Summary Data Sheets Page 18 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 88 119 0.2 98 PCT 7
P2 08H 0.76 TEC TEH 0.61 CBAY2 23 H
91 0
12 90 119 0.32 74 PCT 10 P2 BW1
-0.86 TEC TEH 0.61 CBAY2 23 H
90 0
12 94 119 0.41 77 PCT 13 P2 BW1 0.92 TEC TEH 0.61 CBAY2 23 H
88 0
12 104 119 0.44 116 PCT 13 P2 BW1
-0.92 TEC TEH 0.61 CBAY2 23 H
83 0
12 144 119 0.32 99 PCT 10 P2 BW1
-0.85 VS3 TEH 0.61 CBAY2 39 H
111 0
12 47 120 0.46 136 PCT 13 P2 BW1 0.97 TEC TEH 0.61 CBAY2 13 H
181 7
12 47 120 0.35 57 PCT 10 P2 VS3
-0.91 TEC TEH 0.61 CBAY2 13 H
181 7
12 49 120 1.23 97 PCT 24 P2 BW1 0.96 TEC TEH 0.61 CBAY2 13 H
180 8
12 49 120 2.51 110 WAR 29 0.21 P19 BW1 0.95 VS3 TEH 0.61 NYAX2 59 H
34 F
8 12 51 120 0.58 140 PCT 11 P2 08H 0.74 TEC TEH 0.61 CBAY2 13 H
179 0
12 51 120 0.83 90 PCT 19 P2 BW1 0.97 TEC TEH 0.61 CBAY2 13 H
179 0
12 85 120 0.38 113 PCT 12 P2 VS3
-0.81 TEC TEH 0.61 CBAY2 21 H
65 0
12 87 120 0.25 64 PCT 9
P2 BW1 0.93 TEC TEH 0.61 CBAY2 21 H
66 0
12 87 120 0.49 26 PCT 10 P2 09C 0.85 TEC TEH 0.61 CBAY2 21 H
66 0
12 89 120 0.22 73 PCT 8
P2 BW1 0.77 TEC TEH 0.61 CBAY2 21 H
67 0
12 119 120 0.48 120 PCT 16 P2 VS3
-0.79 VS3 TEC 0.61 CBAY2 58 C
5 0
12 121 120 0.46 104 PCT 15 P2 VS3
-0.79 VS3 TEC 0.61 CBAY2 58 C
6 0
12 143 120 0.27 68 PCT 10 P2 BW2 0.83 VS3 TEC 0.61 CBAY2 284 C
9 0
12 167 120 0.44 137 PCT 12 P2 BW2 0.76 VS3 TEC 0.61 CBAY2 254 C
67 0
12 169 120 0.57 127 PCT 17 P2 BW2 0.9 VS3 TEC 0.61 CBAY2 56 C
5 0
12 46 121 0.61 120 PCT 16 P2 BW2 0.78 TEC TEH 0.61 CBAY2 17 H
41 7
12 58 121 0.72 117 PCT 18 P2 VS3 0.82 TEC TEH 0.61 CBAY2 17 H
86 0
12 80 121 0.29 43 PCT 10 P2 BW1
-0.85 TEC TEH 0.61 CBAY2 21 H
61 0
12 88 121 0.47 96 PCT 14 P2 VS4 0.87 TEC TEH 0.61 CBAY2 21 H
57 0
12 100 121 0.45 39 PCT 14 P2 BW1
-0.77 TEC TEH 0.61 CBAY2 21 H
51 0
12 108 121 0.41 145 PCT 13 P2 BW1 1.59 TEC TEH 0.61 CBAY2 21 H
47 0
12 110 121 0.41 88 PCT 13 P2 BW1
-0.75 TEC TEH 0.61 CBAY2 21 H
46 0
12 112 121 0.28 113 PCT 9
P2 BW1
-0.97 TEC TEH 0.61 CBAY2 37 H
24 0
12 130 121 0.5 139 PCT 13 P2 BW2 0.71 TEC TEH 0.61 CBAY2 29 H
23 0
12 134 121 0.19 93 PCT 6
P2 BW1 0.5 VS3 TEH 0.61 CBAY2 39 H
115 0
12 134 121 0.32 128 PCT 10 P2 BW2
-0.92 VS3 TEC 0.61 CBAY2 252 C
66 0
12 152 121 0.47 105 PCT 14 P2 BW2
-0.9 VS3 TEC 0.61 CBAY2 252 C
97 0
12 162 121 0.28 69 PCT 9
P2 BW1
-0.93 VS3 TEH 0.61 CBAY2 39 H
117 0
12 162 121 0.26 119 PCT 10 P2 VS5
-0.94 VS3 TEC 0.61 CBAY2 56 C
14 0
12 41 122 0.59 56 PCT 16 P2 BW1
-0.84 TEC TEH 0.61 CBAY2 17 H
29 5
12 41 122 1.02 114 PCT 22 P2 BW1 0.92 TEC TEH 0.61 CBAY2 17 H
29 5
12 41 122 1.06 114 PCT 23 P2 BW2
-0.8 TEC TEH 0.61 CBAY2 17 H
29 5
12 41 122 1.99 125 WAR 26 0.14 P19 BW1 0.89 VS3 TEH 0.61 NYAX2 59 H
35 F
5 12 41 122 1.82 118 WAR 25 0.19 P25 BW2
-0.78 VS3 TEC 0.61 NYAX2 264 C
71 F
0 12 43 122 1.09 114 PCT 23 P2 BW1 0.81 TEC TEH 0.61 CBAY2 17 H
39 6
12 43 122 0.53 117 PCT 14 P2 08C 0.8 TEC TEH 0.61 CBAY2 17 H
39 6
12 43 122 1.81 121 WAR 25 0.31 P18 BW1 0.87 VS3 TEH 0.61 NYAX2 59 H
36 T
6 12 49 122 1.18 130 PCT 24 P2 BW2
-0.72 TEC TEH 0.61 CBAY2 17 H
56 0
12 49 122 1.68 110 WAR 24 0.17 P10 BW2
-0.63 VS3 TEC 0.61 NYAX2 264 C
69 F
0 12 61 122 0.22 26 PCT 8
P2 VS3
-0.85 TEH TEC 0.61 CBAY2 246 C
194 0
12 65 122 0.28 79 PCT 10 P2 VS3
-0.82 TEH TEC 0.61 CBAY2 246 C
192 0
12 87 122 0.73 91 PCT 18 P2 BW1 1
TEC TEH 0.61 CBAY2 23 H
67 0
12 105 122 0.44 145 PCT 13 P2 BW1
-0.62 TEC TEH 0.61 CBAY2 23 H
76 0
SG 12 Summary Data Sheets Page 19 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 113 122 0.31 113 PCT 10 P2 BW1 0.44 TEC TEH 0.61 CBAY2 37 H
13 0
12 131 122 0.43 86 PCT 12 P2 BW2 0.74 TEC TEH 0.61 CBAY2 29 H
13 0
12 143 122 0.17 81 PCT 6
P2 BW2 0.76 VS3 TEC 0.61 CBAY2 252 C
98 0
12 149 122 0.12 48 PCT 5
P2 VS3 0.75 VS3 TEC 0.61 CBAY2 252 C
99 0
12 155 122 0.3 75 PCT 10 P2 VS3
-1.1 VS3 TEC 0.61 CBAY2 286 C
13 0
12 155 122 0.38 41 PCT 12 P2 BW2 0.71 VS3 TEC 0.61 CBAY2 286 C
13 0
12 161 122 0.4 119 PCT 12 P2 VS3
-0.97 VS3 TEH 0.61 CBAY2 39 H
118 0
12 167 122 0.82 115 PCT 19 P2 BW2 0.82 VS3 TEC 0.61 CBAY2 254 C
65 0
12 36 123 0.62 104 PCT 16 P2 BW1 0.47 TEC TEH 0.61 CBAY2 17 H
20 4
12 36 123 0.5 33 PCT 11 P2 08C 0.85 TEC TEH 0.61 CBAY2 17 H
20 4
12 38 123 0.4 80 PCT 12 P2 BW2
-0.92 TEC TEH 0.61 CBAY2 17 H
26 5
12 60 123 0.97 94 WAR 19 0.5 P6 VS3 1.15 VS3 TEH 0.61 NYAX2 59 H
39 T
0 12 60 123 0.34 96 PCT 11 P2 VS3 0.74 TEH TEC 0.61 CBAY2 246 C
183 0
12 60 123 0.73 100 PCT 19 P2 VS3 1.06 TEH TEC 0.61 CBAY2 246 C
183 0
12 62 123 1.62 105 WAR 24 0.2 P32 VS2 0.88 VS3 TEH 0.61 NYAX2 59 H
38 F
0 12 62 123 0.99 128 PCT 23 P2 VS2 0.96 TEH TEC 0.61 CBAY2 246 C
184 0
12 68 123 0.31 107 PCT 10 P2 VS3
-0.76 TEH TEC 0.61 CBAY2 246 C
185 0
12 86 123 0.3 120 PCT 10 P2 BW2 1.03 TEC TEH 0.61 CBAY2 23 H
55 0
12 96 123 0.22 56 NQI P1 TSH 4.17 TEC TEH 0.61 CBAY2 23 H
50 0
12 96 123 NDF P17 TSH 4.17 01H TEH 0.61 NYAX2 59 H
37 0
12 108 123 0.51 121 PCT 15 P2 BW1
-1.86 TEC TEH 0.61 CBAY2 21 H
44 0
12 118 123 0.47 115 PCT 13 P2 VS2 0.81 TEC TEH 0.61 CBAY2 29 H
48 0
12 118 123 0.35 100 PCT 10 P2 VS4
-0.92 TEC TEH 0.61 CBAY2 29 H
48 0
12 120 123 0.58 121 PCT 15 P2 VS2 0.88 TEC TEH 0.61 CBAY2 37 H
12 0
12 128 123 0.32 68 PCT 10 P2 BW1
-1.57 TEC TEH 0.61 CBAY2 29 H
18 0
12 130 123 0.32 103 PCT 10 P2 BW1
-0.86 TEC TEH 0.61 CBAY2 29 H
12 0
12 142 123 0.32 140 PCT 10 P2 VS1
-0.82 VS3 TEH 0.61 CBAY2 99 H
233 0
12 166 123 0.34 68 PCT 10 P2 BW2 0.79 VS3 TEC 0.61 CBAY2 254 C
64 0
12 168 123 0.59 86 PCT 17 P2 BW2 1.03 VS3 TEC 0.61 CBAY2 54 C
127 0
12 35 124 0.72 93 PCT 18 P2 BW1 0.83 TEC TEH 0.61 CBAY2 17 H
19 4
12 37 124 0.48 143 PCT 14 P2 BW1 0.89 TEC TEH 0.61 CBAY2 17 H
25 5
12 41 124 0.32 133 PCT 10 P2 VS3 0.7 TEC TEH 0.61 CBAY2 17 H
37 7
12 43 124 2.08 276 PRX P8 08H 24 30 TEC TEH 0.61 CBAY2 17 H
44 8
12 43 124 0.62 82 PCT 16 P2 BW1 0.84 TEC TEH 0.61 CBAY2 17 H
44 8
12 43 124 3.59 178 BOW 143 08H 23.19 32.31 VS3 TEH 0.61 NYAX2 59 H
40 8
12 43 124 1.2 118 WAR 21 P19 BW1 0.68 VS3 TEH 0.61 NYAX2 59 H
40 8
12 63 124 0.29 80 PCT 10 P2 BW1 0.08 TEH TEC 0.61 CBAY2 246 C
175 0
12 77 124 0.28 141 PCT 10 P2 BW1 0.91 TEC TEH 0.61 CBAY2 21 H
25 0
12 85 124 0.31 92 PCT 11 P2 BW1 0.88 TEC TEH 0.61 CBAY2 21 H
29 0
12 89 124 0.33 108 PCT 11 P2 BW1 1.03 TEC TEH 0.61 CBAY2 21 H
31 0
12 109 124 0.41 135 PCT 13 P2 BW1
-1.95 TEC TEH 0.61 CBAY2 21 H
41 0
12 121 124 0.46 135 PCT 13 P2 BW1 0.59 TEC TEH 0.61 CBAY2 29 H
40 0
12 121 124 0.38 85 PCT 11 P2 VS1 0.36 TEC TEH 0.61 CBAY2 29 H
40 0
12 131 124 0.38 126 PCT 11 P2 VS1 0.87 TEC TEH 0.61 CBAY2 29 H
7 0
12 30 125 0.38 124 PCT 10 P2 08H 0.81 TEC TEH 0.61 CBAY2 17 H
12 3
12 30 125 0.92 99 PCT 21 P2 BW1 0.99 TEC TEH 0.61 CBAY2 17 H
12 3
12 30 125 1.43 119 WAR 23 0.17 P4 BW1 0.94 VS3 TEH 0.61 NYAX2 59 H
42 F
3 12 36 125 0.57 93 PCT 16 P2 BW2 0.87 TEC TEH 0.61 CBAY2 17 H
24 6
SG 12 Summary Data Sheets Page 20 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 48 125 0.6 77 PCT 16 P2 09C
-0.48 TEH TEC 0.61 CBAY2 246 C
162 0
12 62 125 0.4 108 PCT 12 P2 VS2 0.96 TEH TEC 0.61 CBAY2 246 C
165 0
12 72 125 0.19 141 PCT 7
P2 VS4 1
TEH TEC 0.61 CBAY2 246 C
170 0
12 78 125 0.27 91 PCT 10 P2 BW1
-0.8 TEC TEH 0.61 CBAY2 21 H
20 0
12 116 125 0.36 108 PCT 11 P2 BW2 0.46 TEC TEH 0.61 CBAY2 29 H
35 0
12 120 125 0.69 106 PCT 17 P2 VS2 0.9 TEC TEH 0.61 CBAY2 29 H
37 0
12 120 125 1.71 108 WAR 24 0.72 P30 VS2 0.83 VS3 TEH 0.61 NYAX2 59 H
41 T
0 12 128 125 0.37 101 PCT 11 P2 VS1
-0.84 TEC TEH 0.61 CBAY2 29 H
11 0
12 130 125 0.38 132 PCT 11 P2 VS2
-0.82 TEC TEH 0.61 CBAY2 29 H
8 0
12 130 125 0.45 117 PCT 12 P2 VS2 0.82 TEC TEH 0.61 CBAY2 29 H
8 0
12 130 125 0.32 92 PCT 10 P2 VS3
-0.53 TEC TEH 0.61 CBAY2 29 H
8 0
12 132 125 NDF P35 FDP 0.71 01C TEC 0.61 NYAX2 264 C
92 0
12 31 126 0.57 86 PCT 16 P2 BW1
-0.93 TEC TEH 0.61 CBAY2 17 H
13 5
12 37 126 1.3 95 PCT 25 P2 BW1
-0.75 TEC TEH 0.61 CBAY2 17 H
32 8
12 37 126 2
141 WAR 27 0.5 P19 BW1
-0.66 VS3 TEH 0.61 NYAX2 59 H
43 T
8 12 41 126 1.11 115 PCT 23 P2 BW1
-0.8 TEC TEH 0.61 CBAY2 17 H
46 0
12 41 126 2.07 88 WAR 27 0.71 P19 BW1
-0.65 VS3 TEH 0.61 NYAX2 59 H
44 T
0 12 43 126 NDF P25 TEH 6.36 01H TEH 0.61 NYAX2 59 H
45 0
12 43 126 8.77 15 OXP 5
TEH 6.36 TEH TEC 0.61 CBAY2 246 C
161 0
12 65 126 0.44 80 PCT 13 P2 VS3
-0.75 TEH TEC 0.61 CBAY2 246 C
154 0
12 121 126 0.34 124 PCT 10 P2 VS1 0.56 TEC TEH 0.61 CBAY2 29 H
33 0
12 131 126 0.38 115 PCT 11 P2 VS3
-0.9 TEC TEH 0.61 CBAY2 29 H
6 0
12 143 126 0.21 57 PCT 7
P2 BW2
-0.85 VS3 TEC 0.61 CBAY2 252 C
101 0
12 153 126 0.23 117 PCT 8
P2 VS2 0.85 VS3 TEH 0.61 CBAY2 39 H
123 0
12 165 126 0.37 79 PCT 13 P2 BW2 0.84 VS3 TEC 0.61 CBAY2 54 C
130 0
12 28 127 0.41 94 PCT 12 P2 08H 0.77 TEC TEH 0.61 CBAY2 17 H
9 4
12 32 127 0.59 135 PCT 13 P2 08H 0.8 TEC TEH 0.61 CBAY2 17 H
11 6
12 36 127 0.31 138 PCT 10 P2 BW2
-0.83 TEC TEH 0.61 CBAY2 17 H
33 8
12 38 127 0.27 133 PCT 9
P2 BW2
-0.81 TEC TEH 0.61 CBAY2 17 H
34 0
12 100 127 0.32 119 PCT 10 P2 BW2
-0.63 TEC TEH 0.61 CBAY2 23 H
10 0
12 108 127 0.27 133 PCT 9
P2 BW1
-1.84 TEC TEH 0.61 CBAY2 23 H
6 0
12 27 128 0.21 103 PCT 7
P2 08C
-0.82 TEH TEC 0.61 CBAY2 246 C
120 6
12 37 128 0.3 101 PCT 10 P2 08C 0.72 TEH TEC 0.61 CBAY2 246 C
125 0
12 47 128 0.28 140 PCT 9
P2 08C
-1.1 TEH TEC 0.61 CBAY2 246 C
130 0
12 49 128 0.48 113 PCT 14 P2 BW1 0.85 TEH TEC 0.61 CBAY2 246 C
131 0
12 99 128 0.47 107 PCT 13 P2 BW1
-0.85 VS3 TEH 0.61 CBAY2 49 H
24 0
12 103 128 0.49 121 PCT 12 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 248 C
69 0
12 121 128 0.28 79 PCT 7
P2 BW2 0.75 TEH TEC 0.61 CBAY2 248 C
76 0
12 125 128 0.42 70 PCT 12 P2 VS1 0.67 VS3 TEH 0.61 CBAY2 49 H
22 0
12 125 128 6
76 PRX P8 10C 17.22 31 TEH TEC 0.61 CBAY2 248 C
78 0
12 125 128 2.21 147 BOW 123 10C 28.91 29.78 VS3 TEC 0.61 NYAX2 264 C
91 0
12 129 128 0.66 128 PCT 16 P2 VS3 0.87 VS3 TEH 0.61 CBAY2 49 H
21 0
12 131 128 0.54 129 PCT 14 P2 VS2
-0.88 VS3 TEH 0.61 CBAY2 49 H
20 0
12 137 128 0.27 46 PCT 10 P2 BW2 0.77 VS3 TEC 0.61 CBAY2 278 C
134 0
12 155 128 0.13 165 PCT 5
P2 VS5 0.97 VS3 TEC 0.61 CBAY2 252 C
102 0
12 159 128 0.12 113 PCT 4
P2 VS5 0.95 VS3 TEC 0.61 CBAY2 254 C
75 0
12 163 128 0.36 122 PCT 12 P2 BW2 0.83 VS3 TEC 0.61 CBAY2 54 C
132 0
12 165 128 0.31 86 PCT 10 P2 BW1 0.94 VS3 TEH 0.61 CBAY2 103 H
61 0
SG 12 Summary Data Sheets Page 21 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 18 129 0.61 43 PCT 17 P2 VS3 0.96 TEH TEC 0.61 CBAY2 246 C
116 3
12 32 129 0.24 50 PCT 8
P2 VS3
-0.74 TEH TEC 0.61 CBAY2 246 C
109 0
12 48 129 0.61 106 PCT 16 P2 09C
-1.17 TEH TEC 0.61 CBAY2 246 C
101 0
12 50 129 0.3 139 PCT 10 P2 VS3
-0.79 TEH TEC 0.61 CBAY2 246 C
100 0
12 68 129 0.73 127 PCT 19 P2 VS2 0.86 TEH TEC 0.61 CBAY2 246 C
91 0
12 98 129 0.37 67 PCT 11 P2 BW1
-0.92 VS3 TEH 0.61 CBAY2 49 H
26 0
12 100 129 0.41 58 PCT 12 P2 BW1
-0.88 VS3 TEH 0.61 CBAY2 49 H
25 0
12 132 129 0.62 129 PCT 15 P2 VS2
-0.83 VS3 TEH 0.61 CBAY2 49 H
19 0
12 136 129 0.22 59 PCT 7
P2 VS3 0.77 VS3 TEH 0.61 CBAY2 49 H
18 0
12 152 129 0.37 145 PCT 11 P2 VS1
-0.86 VS3 TEH 0.61 CBAY2 49 H
9 0
12 160 129 0.52 118 PCT 14 P2 BW2
-0.79 VS3 TEC 0.61 CBAY2 254 C
58 0
12 162 129 0.32 140 PCT 11 P2 VS3
-0.74 VS3 TEC 0.61 CBAY2 54 C
133 0
12 164 129 0.42 121 PCT 11 P2 11C 0.86 VS3 TEC 0.61 CBAY2 286 C
23 0
12 13 130 0.17 123 PCT 6
P2 08H 0.15 TEH TEC 0.61 CBAY2 246 C
65 0
12 17 130 0.48 54 PCT 14 P2 VS3
-0.36 TEH TEC 0.61 CBAY2 246 C
63 0
12 43 130 0.56 75 PCT 16 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 246 C
50 0
12 75 130 0.54 63 PCT 14 P2 BW1 0.97 VS3 TEH 0.61 CBAY2 49 H
28 0
12 89 130 0.69 152 PCT 17 P2 BW1
-0.82 VS3 TEH 0.61 CBAY2 49 H
27 0
12 113 130 0.52 46 PCT 15 P2 VS1
-0.84 TEH TEC 0.61 CBAY2 246 C
23 0
12 129 130 0.29 143 PCT 10 P2 VS3
-0.59 VS3 TEH 0.61 CBAY2 99 H
258 0
12 161 130 0.63 91 PCT 18 P2 BW2 0.84 VS3 TEC 0.61 CBAY2 54 C
134 0
12 163 130 1.11 117 PCT 25 P2 BW2 0.78 VS3 TEC 0.61 CBAY2 54 C
123 0
12 163 130 2.4 105 WAR 28 0.53 P24 BW2 0.63 VS3 TEC 0.61 NYAX2 264 C
93 T
0 12 14 131 0.28 84 PCT 9
P2 08H 0.07 TEH TEC 0.61 CBAY2 246 C
68 0
12 48 131 1.89 113 WAR 26 0.56 P3 BW1 0.9 VS3 TEH 0.61 NYAX2 59 H
46 T
0 12 48 131 1.04 92 PCT 23 P2 BW1 0.94 TEH TEC 0.61 CBAY2 246 C
85 0
12 48 131 0.56 107 PCT 16 P2 BW2
-0.88 TEH TEC 0.61 CBAY2 246 C
85 0
12 50 131 0.24 41 PCT 8
P2 VS3
-0.78 TEH TEC 0.61 CBAY2 246 C
86 0
12 72 131 0.63 59 PCT 18 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 242 C
140 0
12 86 131 0.27 113 PCT 10 P2 VS2 0.74 TEH TEC 0.61 CBAY2 242 C
147 0
12 88 131 0.32 67 PCT 12 P2 BW1
-0.77 TEH TEC 0.61 CBAY2 242 C
148 0
12 88 131 0.3 69 PCT 11 P2 VS2 0.85 TEH TEC 0.61 CBAY2 242 C
148 0
12 160 131 0.39 148 PCT 10 P2 11C 0.77 VS3 TEC 0.61 CBAY2 54 C
135 0
12 164 131 0.35 109 PCT 10 P2 BW2 0.72 VS3 TEC 0.61 CBAY2 254 C
28 0
12 13 132 0.27 105 PCT 11 P2 BW2 1.27 TEH TEC 0.61 CBAY2 210 C
6 0
12 15 132 1.67 77 PLP 7
FDP 1.26 TEH TEC 0.61 CBAY2 210 C
7 SR 0
12 15 132 NDF 188 FDP 1.26 01C TEC 0.61 NYAX2 264 C
73 0
12 19 132 0.8 58 PLP 7
FDP 1.22 TEH TEC 0.61 CBAY2 210 C
8 SR 0
12 19 132 NDF 119 FDP 1.23 01C TEC 0.61 NYAX2 264 C
72 0
12 33 132 0.4 30 PCT 12 P2 08C 0.83 TEH TEC 0.61 CBAY2 210 C
15 0
12 43 132 0.34 56 PCT 13 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 210 C
20 0
12 49 132 0.19 144 PCT 8
P2 08H 0.88 TEH TEC 0.61 CBAY2 210 C
22 0
12 49 132 0.24 84 PCT 10 P2 BW1 0.82 TEH TEC 0.61 CBAY2 210 C
22 0
12 91 132 0.17 129 PCT 7
P2 BW1 1.18 TEH TEC 0.61 CBAY2 242 C
117 0
12 119 132 1.13 110 PCT 23 P2 VS2 1.02 VS3 TEH 0.61 CBAY2 49 H
30 0
12 119 132 2.26 106 WAR 28 0.19 P30 VS2 0.75 VS3 TEH 0.61 NYAX2 59 H
47 F
0 12 161 132 0.27 114 PCT 10 P2 BW2 0.83 VS3 TEC 0.61 CBAY2 54 C
121 0
12 163 132 0.36 140 PCT 10 P2 BW2 0.75 VS3 TEC 0.61 CBAY2 254 C
29 0
SG 12 Summary Data Sheets Page 22 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 22 133 0.25 94 PCT 10 P2 BW1 1.01 TEH TEC 0.61 CBAY2 210 C
51 0
12 46 133 0.44 109 PCT 15 P2 BW1 0.96 TEH TEC 0.61 CBAY2 210 C
39 0
12 54 133 0.28 56 PCT 11 P2 VS3
-0.83 TEH TEC 0.61 CBAY2 210 C
35 0
12 64 133 0.34 86 PCT 13 P2 BW1
-0.79 TEH TEC 0.61 CBAY2 210 C
30 0
12 80 133 0.4 51 PCT 14 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 242 C
87 0
12 82 133 0.27 45 PCT 10 P2 BW1
-0.6 TEH TEC 0.61 CBAY2 242 C
88 0
12 88 133 0.54 60 PCT 17 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 242 C
91 0
12 130 133 0.29 65 PCT 10 P2 VS2 0.79 VS3 TEH 0.61 CBAY2 101 H
279 0
12 134 133 0.36 97 PCT 10 P2 BW1
-0.87 VS3 TEH 0.61 CBAY2 49 H
17 0
12 134 133 0.3 71 PCT 10 P2 BW2
-0.95 VS3 TEC 0.61 CBAY2 252 C
58 0
12 148 133 0.46 79 PCT 13 P2 BW2
-0.78 VS3 TEC 0.61 CBAY2 252 C
105 0
12 162 133 0.39 131 PCT 12 P2 09H 0.76 VS3 TEH 0.61 CBAY2 45 H
155 0
12 162 133 0.36 143 PCT 10 P2 BW2
-0.91 VS3 TEC 0.61 CBAY2 254 C
30 0
12 15 134 0.28 87 PCT 9
P2 BW1
-0.78 TEH TEC 0.61 CBAY2 212 C
7 0
12 43 134 0.32 78 PCT 10 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 212 C
21 0
12 45 134 0.62 96 PCT 16 P2 BW1
-0.9 TEH TEC 0.61 CBAY2 212 C
22 0
12 49 134 0.45 87 PCT 13 P2 BW1
-0.91 TEH TEC 0.61 CBAY2 212 C
24 0
12 57 134 0.3 87 PCT 9
P2 BW1 1.61 TEH TEC 0.61 CBAY2 212 C
28 0
12 91 134 0.33 75 PCT 12 P2 BW1 1.07 TEH TEC 0.61 CBAY2 242 C
19 0
12 129 134 0.29 92 PCT 10 P2 VS3
-0.99 VS3 TEC 0.61 CBAY2 282 C
89 0
12 133 134 0.43 106 PCT 13 P2 BW2
-0.89 VS3 TEC 0.61 CBAY2 252 C
57 0
12 141 134 0.61 91 PCT 15 P2 VS2 0.86 VS3 TEH 0.61 CBAY2 49 H
5 0
12 155 134 0.27 106 PCT 9
P2 VS1
-0.85 VS3 TEH 0.61 CBAY2 47 H
151 0
12 48 135 0.22 159 PCT 8
P2 BW1
-0.76 TEH TEC 0.61 CBAY2 212 C
42 0
12 50 135 0.22 118 PCT 8
P2 BW1
-0.78 TEH TEC 0.61 CBAY2 212 C
41 0
12 64 135 0.39 80 PCT 12 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 212 C
34 0
12 102 135 0.32 58 PCT 12 P2 VS2 0.75 TEH TEC 0.61 CBAY2 242 C
62 0
12 128 135 0.28 100 PCT 11 P2 VS3
-1.06 VS3 TEC 0.61 CBAY2 278 C
75 0
12 130 135 0.81 137 PCT 19 P2 VS3
-0.82 VS3 TEH 0.61 CBAY2 51 H
8 0
12 130 135 2.15 105 WAR 27 0.27 P30 VS3
-0.93 VS3 TEH 0.61 NYAX2 61 H
15 T
0 12 134 135 0.3 72 PCT 10 P2 BW1
-0.87 VS3 TEH 0.61 CBAY2 101 H
284 0
12 156 135 0.45 80 PCT 14 P2 BW2
-0.91 VS3 TEC 0.61 CBAY2 54 C
139 0
12 162 135 0.69 121 PCT 15 P2 03C 0.9 VS3 TEC 0.61 CBAY2 254 C
26 0
12 35 136 0.24 116 PCT 10 P2 BW2
-0.94 TEH TEC 0.61 CBAY2 210 C
71 0
12 127 136 0.38 55 PCT 12 P2 BW2 0.84 VS3 TEC 0.61 CBAY2 252 C
53 0
12 129 136 0.25 130 PCT 10 P2 VS3
-0.87 VS3 TEC 0.61 CBAY2 278 C
74 0
12 131 136 0.18 64 PCT 6
P2 BW2 0.62 VS3 TEC 0.61 CBAY2 252 C
54 0
12 133 136 0.44 41 PCT 13 P2 BW2 0.85 VS3 TEC 0.61 CBAY2 252 C
55 0
12 145 136 0.3 30 PCT 10 P2 BW2 0.82 VS3 TEC 0.61 CBAY2 252 C
107 0
12 2
137 1.22 63 DTI P5 TSC 0.05 TEH TEC 0.61 CBAY2 206 C
16 0
12 2
137 NDF P44 TSC 0.05 01C TEC 0.61 NYAX2 264 C
74 0
12 46 137 0.47 116 PCT 16 P2 BW2
-0.86 TEH TEC 0.61 CBAY2 210 C
96 0
12 46 137 0.12 299 PCT 5
P2 BW2 0.99 TEH TEC 0.61 CBAY2 210 C
96 0
12 124 137 0.27 154 PCT 9
P2 VS1
-0.75 VS3 TEH 0.61 CBAY2 51 H
12 0
12 126 137 0.35 153 PCT 11 P2 VS1
-0.7 VS3 TEH 0.61 CBAY2 51 H
10 0
12 140 137 0.28 61 PCT 9
P2 BW2
-0.91 VS3 TEC 0.61 CBAY2 252 C
50 0
12 142 137 0.34 59 PCT 11 P2 BW2
-0.84 VS3 TEC 0.61 CBAY2 252 C
108 0
12 156 137 0.56 118 PCT 17 P2 VS4 0.84 VS3 TEC 0.61 CBAY2 54 C
116 0
SG 12 Summary Data Sheets Page 23 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 158 137 0.32 89 PCT 10 P2 VS4 0.78 VS3 TEC 0.61 CBAY2 254 C
34 0
12 160 137 0.66 107 PCT 16 P2 BW2
-0.76 VS3 TEC 0.61 CBAY2 254 C
24 0
12 43 138 0.36 30 PCT 11 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 212 C
77 0
12 55 138 0.32 63 PCT 10 P2 BW1 1.97 TEH TEC 0.61 CBAY2 212 C
83 0
12 117 138 0.24 54 PCT 8
P2 BW2 1.11 TEH TEC 0.61 CBAY2 238 C
166 0
12 127 138 0.28 133 PCT 9
P2 VS3
-0.8 VS3 TEH 0.61 CBAY2 51 H
9 0
12 141 138 0.22 64 PCT 8
P2 VS4
-0.81 VS3 TEC 0.61 CBAY2 252 C
109 0
12 159 138 0.28 129 PCT 9
P2 11C 0.75 VS3 TEC 0.61 CBAY2 254 C
23 0
12 46 139 0.21 70 PCT 7
P2 BW1
-0.79 TEH TEC 0.61 CBAY2 212 C
100 0
12 48 139 0.26 41 PCT 8
P2 BW1
-0.85 TEH TEC 0.61 CBAY2 212 C
99 0
12 50 139 0.48 90 PCT 14 P2 BW1
-0.72 TEH TEC 0.61 CBAY2 212 C
98 0
12 50 139 0.22 101 PCT 7
P2 VS3
-0.85 TEH TEC 0.61 CBAY2 212 C
98 0
12 60 139 0.43 101 PCT 13 P2 VS3 0.89 TEH TEC 0.61 CBAY2 212 C
93 0
12 122 139 0.37 163 PCT 11 P2 BW1
-0.92 VS3 TEH 0.61 CBAY2 49 H
40 0
12 130 139 0.56 125 PCT 15 P2 VS2 0.94 VS3 TEH 0.61 CBAY2 49 H
33 0
12 134 139 0.3 95 PCT 10 P2 BW2
-0.89 VS3 TEC 0.61 CBAY2 252 C
46 0
12 144 139 0.31 149 PCT 9
P2 VS1
-0.9 VS3 TEH 0.61 CBAY2 49 H
12 0
12 156 139 0.35 121 PCT 10 P2 11C 0.84 VS3 TEC 0.61 CBAY2 254 C
36 0
12 41 140 0.35 36 PCT 10 P2 08C 0.78 TEH TEC 0.61 CBAY2 210 C
129 0
12 45 140 0.34 56 PCT 13 P2 BW1
-0.8 TEH TEC 0.61 CBAY2 210 C
131 0
12 47 140 0.39 146 PCT 14 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 210 C
132 0
12 59 140 0.32 37 PCT 12 P2 BW1 0.89 TEH TEC 0.61 CBAY2 210 C
138 0
12 77 140 0.46 108 PCT 14 P2 BW1 0.89 TEH TEC 0.61 CBAY2 238 C
92 0
12 77 140 0.29 117 PCT 10 P2 VS3
-0.84 TEH TEC 0.61 CBAY2 238 C
92 0
12 93 140 2.64 178 DNT P1 09C 21.32 TEH TEC 0.61 CBAY2 238 C
100 0
12 123 140 0.32 26 PCT 10 P2 BW2 0.82 VS3 TEC 0.61 CBAY2 252 C
43 0
12 129 140 0.56 153 PCT 15 P2 BW1 0.9 VS3 TEH 0.61 CBAY2 49 H
34 0
12 129 140 0.3 144 PCT 9
P2 VS3
-0.8 VS3 TEH 0.61 CBAY2 49 H
34 0
12 131 140 0.4 83 PCT 11 P2 BW1
-0.78 VS3 TEH 0.61 CBAY2 49 H
37 0
12 135 140 0.34 106 PCT 10 P2 VS1
-0.84 VS3 TEH 0.61 CBAY2 105 H
12 0
12 139 140 0.35 48 PCT 10 P2 VS1 0.85 VS3 TEH 0.61 CBAY2 103 H
9 0
12 8
141 0.25 61 PCT 10 P2 BW1 1.01 TEH TEC 0.61 CBAY2 202 C
158 0
12 24 141 0.36 149 PCT 13 P2 BW1 0.97 TEH TEC 0.61 CBAY2 210 C
161 0
12 28 141 0.26 30 PCT 10 P2 04C 0.76 TEH TEC 0.61 CBAY2 210 C
159 0
12 38 141 0.24 144 PCT 10 P2 08C 0.79 TEH TEC 0.61 CBAY2 210 C
154 0
12 44 141 0.27 52 PCT 11 P2 BW1
-0.75 TEH TEC 0.61 CBAY2 210 C
151 0
12 48 141 0.23 87 PCT 10 P2 05H
-0.83 TEH TEC 0.61 CBAY2 210 C
149 0
12 48 141 0.32 50 PCT 11 P2 09C
-1.61 TEH TEC 0.61 CBAY2 210 C
149 0
12 62 141 0.28 74 PCT 11 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 210 C
142 0
12 100 141 0.34 121 PCT 11 P2 VS2 0.82 TEH TEC 0.61 CBAY2 238 C
76 0
12 128 141 0.42 106 PCT 12 P2 VS2 1.07 VS3 TEH 0.61 CBAY2 49 H
35 0
12 130 141 0.31 132 PCT 10 P2 VS1 0.88 VS3 TEH 0.61 CBAY2 101 H
309 0
12 136 141 0.25 75 PCT 8
P2 BW1
-0.9 VS3 TEH 0.61 CBAY2 49 H
15 0
12 156 141 0.29 96 PCT 10 P2 BW2
-1.16 VS3 TEC 0.61 CBAY2 282 C
11 0
12 45 142 0.36 49 PCT 11 P2 BW1
-0.86 TEH TEC 0.61 CBAY2 212 C
135 0
12 61 142 0.51 103 PCT 14 P2 BW1 0.88 TEH TEC 0.61 CBAY2 212 C
143 0
12 119 142 0.88 109 PCT 19 P2 VS3
-0.8 VS3 TEH 0.61 CBAY2 49 H
41 0
12 127 142 0.3 84 PCT 10 P2 BW1 0.88 VS3 TEH 0.61 CBAY2 101 H
281 0
SG 12 Summary Data Sheets Page 24 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 129 142 0.33 78 PCT 10 P2 VS3
-0.75 VS3 TEH 0.61 CBAY2 101 H
310 0
12 131 142 0.43 109 PCT 12 P2 VS1
-0.76 VS3 TEH 0.61 CBAY2 49 H
38 0
12 50 143 0.59 107 PCT 16 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 212 C
154 0
12 74 143 0.35 51 PCT 13 P2 BW1
-0.76 TEH TEC 0.61 CBAY2 242 C
129 0
12 90 143 0.34 73 PCT 11 P2 10H
-1.16 TEH TEC 0.61 CBAY2 238 C
27 0
12 108 143 0.47 117 PCT 14 P2 BW1
-1.86 TEH TEC 0.61 CBAY2 238 C
18 0
12 112 143 0.43 86 PCT 13 P2 BW1
-0.92 TEH TEC 0.61 CBAY2 238 C
16 0
12 136 143 0.43 130 PCT 12 P2 VS1
-0.8 VS3 TEH 0.61 CBAY2 49 H
14 0
12 55 144 0.33 98 PCT 12 P2 BW1 1.91 TEH TEC 0.61 CBAY2 210 C
190 0
12 61 144 0.44 120 PCT 15 P2 BW1 0.69 TEH TEC 0.61 CBAY2 210 C
193 0
12 63 144 0.44 86 PCT 15 P2 BW1 1.02 TEH TEC 0.61 CBAY2 210 C
194 0
12 109 144 0.35 133 PCT 11 P2 BW1
-1.94 TEH TEC 0.61 CBAY2 234 C
229 0
12 111 144 0.42 123 PCT 13 P2 BW1
-0.86 TEH TEC 0.61 CBAY2 234 C
230 0
12 113 144 0.4 126 PCT 10 P2 VS2
-0.66 TEH TEC 0.61 CBAY2 248 C
151 0
12 119 144 0.32 107 PCT 11 P2 VS2 0.87 TEH TEC 0.61 CBAY2 238 C
10 0
12 153 144 0.3 123 PCT 10 P2 VS1
-0.84 VS3 TEH 0.61 CBAY2 103 H
111 0
12 50 145 0.22 96 PCT 9
P2 BW1
-0.91 TEH TEC 0.61 CBAY2 210 C
202 0
12 50 145 0.33 122 PCT 12 P2 BW1 0.7 TEH TEC 0.61 CBAY2 210 C
202 0
12 62 145 0.29 137 PCT 11 P2 VS2 0.88 TEH TEC 0.61 CBAY2 210 C
196 0
12 84 145 0.39 81 PCT 12 P2 VS2 0.81 TEH TEC 0.61 CBAY2 234 C
197 0
12 88 145 0.29 88 PCT 10 P2 VS4
-0.74 TEH TEC 0.61 CBAY2 234 C
195 0
12 106 145 0.49 102 PCT 14 P2 BW1
-1.5 TEH TEC 0.61 CBAY2 234 C
186 0
12 110 145 0.49 109 PCT 14 P2 BW1
-0.72 TEH TEC 0.61 CBAY2 234 C
184 0
12 114 145 0.66 118 PCT 18 P2 BW1 1.02 TEH TEC 0.61 CBAY2 234 C
182 0
12 114 145 0.29 104 PCT 10 P2 VS2
-0.78 TEH TEC 0.61 CBAY2 234 C
182 0
12 114 145 0.23 98 PCT 8
P2 VS4
-0.61 TEH TEC 0.61 CBAY2 234 C
182 0
12 116 145 0.6 79 PCT 16 P2 BW1 0.58 TEH TEC 0.61 CBAY2 234 C
181 0
12 116 145 0.23 73 PCT 8
P2 VS2 0.9 TEH TEC 0.61 CBAY2 234 C
181 0
12 116 145 0.25 67 PCT 9
P2 VS4
-0.69 TEH TEC 0.61 CBAY2 234 C
181 0
12 118 145 0.37 88 PCT 12 P2 BW1 0.58 TEH TEC 0.61 CBAY2 234 C
180 0
12 120 145 0.6 108 PCT 16 P2 BW1 0.47 TEH TEC 0.61 CBAY2 234 C
179 0
12 120 145 0.44 66 PCT 13 P2 VS2 0.87 TEH TEC 0.61 CBAY2 234 C
179 0
12 120 145 0.26 96 PCT 9
P2 VS4
-0.72 TEH TEC 0.61 CBAY2 234 C
179 0
12 128 145 0.23 97 PCT 8
P2 BW2
-0.93 VS3 TEC 0.61 CBAY2 252 C
33 0
12 130 145 0.25 134 PCT 10 P2 VS4 0.8 VS3 TEC 0.61 CBAY2 278 C
6 0
12 45 146 0.51 77 PCT 14 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 212 C
191 0
12 53 146 0.42 118 PCT 12 P2 BW1 1.53 TEH TEC 0.61 CBAY2 212 C
195 0
12 55 146 0.44 134 PCT 13 P2 BW1 1.28 TEH TEC 0.61 CBAY2 212 C
196 0
12 97 146 0.3 47 PCT 10 P2 BW1 0.92 TEH TEC 0.61 CBAY2 234 C
162 0
12 99 146 0.35 97 PCT 11 P2 BW1 1.05 TEH TEC 0.61 CBAY2 234 C
163 0
12 101 146 0.36 50 PCT 11 P2 BW1 1.04 TEH TEC 0.61 CBAY2 234 C
164 0
12 107 146 0.51 52 PCT 15 P2 BW1 1.23 TEH TEC 0.61 CBAY2 234 C
167 0
12 129 146 0.3 139 PCT 10 P2 VS3
-0.89 VS3 TEH 0.61 CBAY2 51 H
13 0
12 149 146 0.31 138 PCT 10 P2 VS1 0.82 VS3 TEH 0.61 CBAY2 103 H
76 0
12 153 146 0.3 136 PCT 10 P2 11H 0.67 VS3 TEH 0.61 CBAY2 103 H
98 0
12 46 147 0.42 105 PCT 12 P2 BW1
-0.89 TEH TEC 0.61 CBAY2 212 C
211 0
12 48 147 0.75 110 PCT 18 P2 09C
-1.22 TEH TEC 0.61 CBAY2 212 C
210 0
12 54 147 0.35 100 PCT 11 P2 BW1 1.38 TEH TEC 0.61 CBAY2 212 C
207 0
SG 12 Summary Data Sheets Page 25 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 76 147 0.35 92 PCT 11 P2 VS2
-0.68 TEH TEC 0.61 CBAY2 234 C
142 0
12 80 147 0.33 102 PCT 11 P2 VS2
-0.67 TEH TEC 0.61 CBAY2 234 C
140 0
12 88 147 0.57 135 PCT 16 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 234 C
136 0
12 104 147 0.54 69 PCT 15 P2 BW1
-0.74 TEH TEC 0.61 CBAY2 234 C
129 0
12 112 147 0.48 136 PCT 14 P2 BW1
-1.51 TEH TEC 0.61 CBAY2 234 C
125 0
12 114 147 0.3 79 PCT 10 P2 VS3
-0.99 TEH TEC 0.61 CBAY2 234 C
124 0
12 118 147 0.54 110 PCT 15 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 234 C
122 0
12 120 147 0.27 30 PCT 9
P2 BW1
-0.79 TEH TEC 0.61 CBAY2 234 C
121 0
12 126 147 0.27 73 PCT 9
P2 BW1
-0.82 VS3 TEH 0.61 CBAY2 51 H
18 0
12 126 147 1.06 105 PCT 23 P2 VS3
-1.09 VS3 TEH 0.61 CBAY2 51 H
18 0
12 126 147 2.62 98 WAR 29 0.35 P30 VS3
-0.91 VS3 TEH 0.61 NYAX2 61 H
16 T
0 12 39 148 0.32 88 PCT 12 P2 BW1 0.99 TEH TEC 0.61 CBAY2 210 C
236 0
12 49 148 0.3 74 PCT 11 P2 BW1 0.85 TEH TEC 0.61 CBAY2 210 C
241 0
12 51 148 0.35 112 PCT 13 P2 BW1 0.9 TEH TEC 0.61 CBAY2 210 C
242 0
12 57 148 0.28 132 PCT 11 P2 BW1
-1.89 TEH TEC 0.61 CBAY2 210 C
245 0
12 61 148 0.35 71 PCT 13 P2 VS2
-0.86 TEH TEC 0.61 CBAY2 210 C
247 0
12 63 148 0.27 118 PCT 11 P2 VS3
-0.85 TEH TEC 0.61 CBAY2 210 C
248 0
12 65 148 0.37 116 PCT 12 P2 VS3
-0.85 TEH TEC 0.61 CBAY2 234 C
89 0
12 69 148 0.31 125 PCT 10 P2 VS3
-1.03 TEH TEC 0.61 CBAY2 234 C
91 0
12 83 148 0.21 58 PCT 7
P2 VS4
-0.72 TEH TEC 0.61 CBAY2 234 C
98 0
12 101 148 0.26 89 PCT 9
P2 BW2
-0.83 TEH TEC 0.61 CBAY2 234 C
107 0
12 103 148 0.23 137 PCT 8
P2 BW2 0.74 TEH TEC 0.61 CBAY2 234 C
108 0
12 111 148 0.2 57 PCT 7
P2 BW1
-1.8 TEH TEC 0.61 CBAY2 234 C
112 0
12 111 148 0.32 114 PCT 11 P2 BW2
-0.85 TEH TEC 0.61 CBAY2 234 C
112 0
12 115 148 0.46 77 PCT 14 P2 VS2 0.73 TEH TEC 0.61 CBAY2 234 C
114 0
12 115 148 0.39 100 PCT 12 P2 VS4 1.05 TEH TEC 0.61 CBAY2 234 C
114 0
12 117 148 0.23 112 PCT 8
P2 VS2 0.86 TEH TEC 0.61 CBAY2 234 C
115 0
12 117 148 0.51 45 PCT 15 P2 BW2 0.63 TEH TEC 0.61 CBAY2 234 C
115 0
12 119 148 0.36 90 PCT 11 P2 BW2 0.86 TEH TEC 0.61 CBAY2 234 C
116 0
12 121 148 0.93 104 PCT 22 P2 BW2 0.88 TEH TEC 0.61 CBAY2 234 C
117 0
12 121 148 1.7 120 WAR 24 0.16 P23 BW2 0.82 VS3 TEC 0.61 NYAX2 264 C
90 F
0 12 123 148 0.39 93 PCT 12 P2 BW2 0.83 TEH TEC 0.61 CBAY2 234 C
118 0
12 125 148 0.29 57 PCT 10 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 234 C
119 0
12 125 148 0.29 110 PCT 10 P2 VS2
-0.73 TEH TEC 0.61 CBAY2 234 C
119 0
12 127 148 0.31 31 PCT 10 P2 BW2 0.92 VS3 TEC 0.61 CBAY2 252 C
30 0
12 129 148 0.45 94 PCT 13 P2 BW2 0.79 VS3 TEC 0.61 CBAY2 252 C
29 0
12 131 148 0.91 118 PCT 20 P2 VS2 0.78 VS3 TEH 0.61 CBAY2 49 H
43 0
12 131 148 1.27 114 WAR 21 0.28 P31 VS2 0.84 VS3 TEH 0.61 NYAX2 63 H
5 F
0 12 42 149 0.33 107 PCT 13 P2 BW2 1.02 TEH TEC 0.61 CBAY2 210 C
260 0
12 48 149 0.25 107 PCT 10 P2 09C
-1.56 TEH TEC 0.61 CBAY2 210 C
257 0
12 60 149 0.2 138 PCT 8
P2 VS3 0.97 TEH TEC 0.61 CBAY2 210 C
251 0
12 86 149 0.37 64 PCT 12 P2 BW1
-0.83 TEH TEC 0.61 CBAY2 234 C
78 0
12 88 149 0.46 104 PCT 14 P2 BW1
-0.83 TEH TEC 0.61 CBAY2 234 C
77 0
12 98 149 0.32 67 PCT 10 P2 BW2
-0.73 TEH TEC 0.61 CBAY2 234 C
72 0
12 104 149 0.31 62 PCT 10 P2 VS2 0.88 TEH TEC 0.61 CBAY2 234 C
69 0
12 112 149 0.32 99 PCT 11 P2 BW2
-0.63 TEH TEC 0.61 CBAY2 234 C
65 0
12 116 149 0.35 79 PCT 11 P2 VS3 0.99 TEH TEC 0.61 CBAY2 234 C
63 0
12 118 149 0.31 97 PCT 10 P2 VS3
-0.86 TEH TEC 0.61 CBAY2 234 C
62 0
SG 12 Summary Data Sheets Page 26 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 120 149 0.24 63 PCT 8
P2 VS2
-0.73 TEH TEC 0.61 CBAY2 234 C
61 0
12 120 149 0.4 133 PCT 13 P2 BW2 0.68 TEH TEC 0.61 CBAY2 234 C
61 0
12 124 149 0.47 114 PCT 14 P2 BW2
-0.87 TEH TEC 0.61 CBAY2 234 C
59 0
12 124 149 0.4 101 PCT 12 P2 BW2 0.81 TEH TEC 0.61 CBAY2 234 C
59 0
12 126 149 0.3 74 PCT 10 P2 VS2 1.07 VS3 TEH 0.61 CBAY2 51 H
17 0
12 126 149 0.43 43 PCT 13 P2 BW2 0.84 VS3 TEC 0.61 CBAY2 252 C
25 0
12 128 149 0.3 141 PCT 10 P2 VS2
-0.78 VS3 TEH 0.61 CBAY2 51 H
15 0
12 130 149 0.53 121 PCT 14 P2 VS1 0.76 VS3 TEH 0.61 CBAY2 49 H
45 0
12 130 149 0.35 90 PCT 11 P2 VS4
-0.56 VS3 TEC 0.61 CBAY2 252 C
27 0
12 144 149 0.16 152 PCT 6
P2 VS3
-0.93 VS3 TEH 0.61 CBAY2 51 H
34 0
12 150 149 0.4 130 PCT 13 P2 11H 0.71 VS3 TEH 0.61 CBAY2 45 H
183 0
12 150 149 0.21 130 PCT 8
P2 BW1
-0.83 VS3 TEH 0.61 CBAY2 45 H
183 0
12 35 150 0.36 118 PCT 11 P2 BW1 0.99 TEH TEC 0.61 CBAY2 212 C
240 0
12 47 150 3.03 89 PRX P8 08C 15.24 35.05 TEH TEC 0.61 CBAY2 212 C
246 0
12 47 150 4.98 172 BOW 59 08C 22.33 35.64 VS3 TEC 0.61 NYAX2 264 C
82 0
12 51 150 0.35 58 PCT 11 P2 BW1 0.97 TEH TEC 0.61 CBAY2 212 C
248 0
12 55 150 0.39 132 PCT 12 P2 BW1 1.36 TEH TEC 0.61 CBAY2 212 C
250 0
12 69 150 0.29 124 PCT 10 P2 VS2 0.88 TEH TEC 0.61 CBAY2 234 C
31 0
12 79 150 0.4 123 PCT 12 P2 BW1 1.18 TEH TEC 0.61 CBAY2 234 C
36 0
12 87 150 0.3 44 PCT 10 P2 BW1 0.99 TEH TEC 0.61 CBAY2 234 C
40 0
12 109 150 0.31 64 PCT 10 P2 VS2
-0.91 TEH TEC 0.61 CBAY2 234 C
50 0
12 109 150 0.43 59 PCT 13 P2 VS3
-1.03 TEH TEC 0.61 CBAY2 234 C
50 0
12 111 150 0.34 141 PCT 11 P2 BW1
-1.42 TEH TEC 0.61 CBAY2 234 C
51 0
12 111 150 0.35 79 PCT 11 P2 BW1
-0.71 TEH TEC 0.61 CBAY2 234 C
51 0
12 115 150 0.32 37 PCT 10 P2 VS5 0.59 TEH TEC 0.61 CBAY2 234 C
53 0
12 117 150 1.85 103 WAR 25 0.65 P30 VS3
-0.81 VS3 TEH 0.61 NYAX2 61 H
17 T
0 12 117 150 0.79 110 PCT 20 P2 VS3
-0.88 TEH TEC 0.61 CBAY2 234 C
54 0
12 119 150 0.32 75 PCT 10 P2 BW1 0.86 TEH TEC 0.61 CBAY2 234 C
55 0
12 125 150 0.38 96 PCT 12 P2 VS1 0.86 TEH TEC 0.61 CBAY2 234 C
58 0
12 125 150 0.43 111 PCT 13 P2 BW2 0.89 TEH TEC 0.61 CBAY2 234 C
58 0
12 127 150 0.68 92 PCT 18 P2 BW2 0.86 VS3 TEC 0.61 CBAY2 252 C
24 0
12 131 150 0.46 76 PCT 13 P2 VS1 0.72 VS3 TEH 0.61 CBAY2 49 H
44 0
12 149 150 0.58 155 PCT 10 P2 11H 0.67 VS3 TEH 0.61 CBAY2 103 H
95 0
12 46 151 0.39 37 PCT 12 P2 BW1
-0.75 TEH TEC 0.61 CBAY2 212 C
266 0
12 48 151 0.63 118 PCT 15 P2 09C
-1.52 TEH TEC 0.61 CBAY2 212 C
265 0
12 50 151 0.23 99 PCT 8
P2 VS3
-0.83 TEH TEC 0.61 CBAY2 212 C
264 0
12 72 151 0.56 112 PCT 16 P2 VS4
-0.85 TEH TEC 0.61 CBAY2 234 C
27 0
12 74 151 0.29 90 PCT 10 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 234 C
26 0
12 98 151 0.29 83 PCT 10 P2 05C 0.73 TEH TEC 0.61 CBAY2 234 C
14 0
12 108 151 0.38 114 PCT 12 P2 BW1
-1.6 TEH TEC 0.61 CBAY2 234 C
9 0
12 110 151 0.6 91 PCT 16 P2 BW1
-0.77 TEH TEC 0.61 CBAY2 234 C
8 0
12 110 151 0.56 114 PCT 16 P2 VS2
-0.63 TEH TEC 0.61 CBAY2 234 C
8 0
12 118 151 0.37 133 PCT 12 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 232 C
125 0
12 118 151 0.56 121 PCT 16 P2 BW2 1.02 TEH TEC 0.61 CBAY2 232 C
125 0
12 124 151 0.27 106 PCT 10 P2 BW2
-0.96 TEH TEC 0.61 CBAY2 232 C
122 0
12 132 151 0.52 111 PCT 14 P2 VS2 0.9 VS3 TEH 0.61 CBAY2 49 H
46 0
12 132 151 0.32 66 PCT 10 P2 BW2 0.73 VS3 TEC 0.61 CBAY2 252 C
19 0
12 134 151 0.41 99 PCT 12 P2 VS3
-1.01 VS3 TEH 0.61 CBAY2 49 H
47 0
SG 12 Summary Data Sheets Page 27 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 79 152 0.28 55 PCT 10 P2 VS3
-0.83 TEH TEC 0.61 CBAY2 232 C
59 0
12 81 152 0.58 111 PCT 16 P2 VS4 0.85 TEH TEC 0.61 CBAY2 232 C
60 0
12 81 152 0.16 131 PCT 6
P2 09C
-1.01 TEH TEC 0.61 CBAY2 232 C
60 0
12 95 152 0.25 96 PCT 9
P2 VS2 0.78 TEH TEC 0.61 CBAY2 232 C
67 0
12 113 152 0.3 88 PCT 10 P2 BW1 0.94 TEH TEC 0.61 CBAY2 232 C
115 0
12 113 152 0.24 102 PCT 9
P2 VS3
-0.78 TEH TEC 0.61 CBAY2 232 C
115 0
12 121 152 0.39 60 PCT 12 P2 BW2
-0.95 TEH TEC 0.61 CBAY2 232 C
119 0
12 131 152 0.26 140 PCT 9
P2 VS1
-0.7 VS3 TEH 0.61 CBAY2 51 H
24 0
12 131 152 0.63 132 PCT 17 P2 VS2
-0.67 VS3 TEH 0.61 CBAY2 51 H
24 0
12 131 152 0.57 118 PCT 16 P2 BW2
-1.02 VS3 TEC 0.61 CBAY2 252 C
18 0
12 135 152 0.36 74 PCT 11 P2 VS3 0.95 VS3 TEH 0.61 CBAY2 49 H
52 0
12 149 152 0.3 134 PCT 10 P2 11H 0.66 VS3 TEH 0.61 CBAY2 103 H
85 0
12 34 153 0.24 152 PCT 10 P2 BW1 0.9 TEH TEC 0.61 CBAY2 210 C
318 0
12 74 153 0.3 102 PCT 10 P2 VS2
-0.75 TEH TEC 0.61 CBAY2 232 C
25 0
12 74 153 0.28 104 PCT 10 P2 VS3 0.74 TEH TEC 0.61 CBAY2 232 C
25 0
12 76 153 0.3 85 PCT 10 P2 VS2 0.78 TEH TEC 0.61 CBAY2 232 C
29 0
12 84 153 0.23 108 PCT 8
P2 VS2 0.84 TEH TEC 0.61 CBAY2 232 C
32 0
12 90 153 0.4 103 PCT 13 P2 BW1
-0.74 TEH TEC 0.61 CBAY2 232 C
35 0
12 124 153 0.24 85 PCT 9
P2 VS2
-0.92 TEH TEC 0.61 CBAY2 232 C
94 0
12 128 153 0.34 43 PCT 11 P2 BW2 0.87 VS3 TEC 0.61 CBAY2 252 C
14 0
12 130 153 0.36 101 PCT 11 P2 BW1 0.97 VS3 TEH 0.61 CBAY2 51 H
23 0
12 130 153 0.4 141 PCT 12 P2 VS2
-0.88 VS3 TEH 0.61 CBAY2 51 H
23 0
12 130 153 0.21 44 PCT 7
P2 VS4 0.99 VS3 TEC 0.61 CBAY2 252 C
15 0
12 132 153 0.63 125 PCT 16 P2 VS1 0.72 VS3 TEH 0.61 CBAY2 49 H
48 0
12 132 153 0.22 110 PCT 7
P2 VS2
-0.96 VS3 TEH 0.61 CBAY2 49 H
48 0
12 1
154 0.16 113 DSI P6 FDP 0.23 TEH TEC 0.61 CBAY2 202 C
151 0
12 1
154 NDF P39 FDP 0.23 01C TEC 0.61 NYAX2 264 C
75 0
12 35 154 0.38 141 PCT 11 P2 BW1
-0.89 TEH TEC 0.61 CBAY2 212 C
296 0
12 47 154 1.32 95 PRX P8 08C 29 36 TEH TEC 0.61 CBAY2 212 C
302 0
12 47 154 7.26 159 BOW 27 08C 33.39 35.81 VS3 TEC 0.61 NYAX2 264 C
79 0
12 79 154 0.31 62 PCT 11 P2 VS4 1
TEH TEC 0.61 CBAY2 232 C
12 0
12 101 154 0.3 147 PCT 10 P2 BW1
-0.86 TEH TEC 0.61 CBAY2 232 C
46 0
12 101 154 0.33 114 PCT 11 P2 VS2
-0.81 TEH TEC 0.61 CBAY2 232 C
46 0
12 109 154 0.33 34 PCT 11 P2 BW1 2
TEH TEC 0.61 CBAY2 232 C
85 0
12 117 154 0.29 47 PCT 10 P2 VS5 0.85 TEH TEC 0.61 CBAY2 232 C
89 0
12 121 154 0.38 57 PCT 12 P2 BW1 1.12 TEH TEC 0.61 CBAY2 232 C
91 0
12 127 154 0.28 131 PCT 9
P2 BW1 0.74 VS3 TEH 0.61 CBAY2 51 H
21 0
12 131 154 0.28 134 PCT 9
P2 VS1
-0.82 VS3 TEH 0.61 CBAY2 49 H
49 0
12 133 154 0.42 110 PCT 13 P2 BW2
-0.89 VS3 TEC 0.61 CBAY2 252 C
11 0
12 145 154 0.69 153 PCT 10 P2 11H 0.69 VS3 TEH 0.61 CBAY2 103 H
91 0
12 56 155 0.3 37 PCT 10 P2 BW1 1.86 TEH TEC 0.61 CBAY2 212 C
317 0
12 58 155 0.33 134 PCT 10 P2 VS2 0.92 TEH TEC 0.61 CBAY2 212 C
316 0
12 64 155 0.55 118 PCT 14 P2 08C 0.84 TEH TEC 0.61 CBAY2 212 C
313 0
12 70 155 0.23 115 PCT 10 P2 BW1
-0.83 TEH TEC 0.61 CBAY2 230 C
36 0
12 74 155 0.3 128 PCT 12 P2 VS2 0.81 TEH TEC 0.61 CBAY2 230 C
38 0
12 80 155 0.27 147 PCT 11 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 230 C
39 0
12 102 155 0.34 59 PCT 11 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 232 C
70 0
12 102 155 0.3 84 PCT 10 P2 VS3
-0.92 TEH TEC 0.61 CBAY2 232 C
70 0
SG 12 Summary Data Sheets Page 28 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 114 155 0.28 26 PCT 10 P2 VS1 0.94 TEH TEC 0.61 CBAY2 232 C
76 0
12 128 155 0.39 35 PCT 12 P2 VS4
-0.68 VS3 TEC 0.61 CBAY2 252 C
8 0
12 130 155 0.42 90 PCT 12 P2 BW1 0.91 VS3 TEH 0.61 CBAY2 49 H
50 0
12 130 155 0.49 107 PCT 13 P2 VS2 0.9 VS3 TEH 0.61 CBAY2 49 H
50 0
12 134 155 0.44 100 PCT 12 P2 BW1
-0.85 VS3 TEH 0.61 CBAY2 49 H
53 0
12 146 155 0.44 114 PCT 13 P2 03C 0.83 VS3 TEC 0.61 CBAY2 54 C
79 0
12 41 156 0.26 53 PCT 10 P2 08C 0.88 TEH TEC 0.61 CBAY2 210 C
345 0
12 53 156 0.25 152 PCT 10 P2 BW1
-0.57 TEH TEC 0.61 CBAY2 210 C
351 0
12 63 156 0.39 48 PCT 13 P2 09C
-0.87 TEH TEC 0.61 CBAY2 210 C
356 0
12 69 156 0.34 150 PCT 11 P2 09H 0.85 TEH TEC 0.61 CBAY2 230 C
7 0
12 71 156 0.26 123 PCT 11 P2 VS2
-0.72 TEH TEC 0.61 CBAY2 230 C
8 0
12 75 156 0.34 95 PCT 13 P2 VS2
-0.84 TEH TEC 0.61 CBAY2 230 C
10 0
12 77 156 0.22 100 PCT 9
P2 08C 0.72 TEH TEC 0.61 CBAY2 230 C
11 0
12 83 156 0.2 108 PCT 9
P2 VS4
-0.62 TEH TEC 0.61 CBAY2 230 C
14 0
12 87 156 0.23 138 PCT 10 P2 VS4
-0.69 TEH TEC 0.61 CBAY2 230 C
16 0
12 101 156 0.28 142 PCT 11 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 228 C
89 0
12 109 156 0.25 109 PCT 10 P2 10C 0.66 TEH TEC 0.61 CBAY2 228 C
85 0
12 125 156 0.58 22 PCT 11 P2 06H
-0.87 TEH TEC 0.61 CBAY2 228 C
77 0
12 137 156 0.25 51 PCT 10 P2 VS3
-0.86 TEH TEC 0.61 CBAY2 228 C
71 0
12 139 156 0.25 49 PCT 10 P2 VS1
-0.75 TEH TEC 0.61 CBAY2 228 C
70 0
12 145 156 0.31 105 PCT 11 P2 04C
-1.01 VS3 TEC 0.61 CBAY2 54 C
78 0
12 60 157 0.39 98 PCT 14 P2 VS3
-0.81 TEH TEC 0.61 CBAY2 210 C
359 0
12 66 157 0.29 145 PCT 11 P2 08C 0.77 TEH TEC 0.61 CBAY2 228 C
150 0
12 72 157 0.31 91 PCT 11 P2 VS2
-0.84 TEH TEC 0.61 CBAY2 228 C
147 0
12 76 157 0.31 55 PCT 11 P2 VS2 0.75 TEH TEC 0.61 CBAY2 228 C
145 0
12 78 157 0.29 31 PCT 11 P2 VS2 0.92 TEH TEC 0.61 CBAY2 228 C
144 0
12 84 157 0.49 134 PCT 15 P2 VS4
-0.7 TEH TEC 0.61 CBAY2 228 C
141 0
12 98 157 0.31 57 PCT 11 P2 BW2
-0.71 TEH TEC 0.61 CBAY2 228 C
134 0
12 100 157 0.3 123 PCT 11 P2 BW1
-0.76 TEH TEC 0.61 CBAY2 228 C
50 0
12 100 157 0.41 58 PCT 14 P2 BW2
-0.83 TEH TEC 0.61 CBAY2 228 C
50 0
12 102 157 0.34 152 PCT 12 P2 BW2
-0.96 TEH TEC 0.61 CBAY2 228 C
51 0
12 104 157 0.28 104 PCT 10 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 228 C
52 0
12 108 157 0.54 104 PCT 16 P2 BW1
-1.83 TEH TEC 0.61 CBAY2 228 C
54 0
12 112 157 0.36 65 PCT 12 P2 BW1 1.15 TEH TEC 0.61 CBAY2 228 C
56 0
12 116 157 0.26 82 PCT 10 P2 VS2
-0.69 TEH TEC 0.61 CBAY2 228 C
58 0
12 118 157 1.4 105 WAR 22 0.14 P17 BW1
-0.9 VS3 TEH 0.61 NYAX2 61 H
18 F
0 12 118 157 0.72 67 PCT 20 P2 BW1
-0.86 TEH TEC 0.61 CBAY2 228 C
59 0
12 130 157 0.65 112 PCT 19 P2 VS2
-0.63 TEH TEC 0.61 CBAY2 228 C
65 0
12 130 157 0.39 80 PCT 13 P2 VS4
-0.67 TEH TEC 0.61 CBAY2 228 C
65 0
12 130 157 0.96 100 PCT 23 P2 VS5
-0.75 TEH TEC 0.61 CBAY2 228 C
65 0
12 130 157 2.29 102 WAR 28 0.22 P10 VS5
-0.94 VS3 TEC 0.61 NYAX2 264 C
88 F
0 12 130 157 3.53 118 DEP 11 TSC 0.44 VS3 TEC 0.61 NYAX2 264 C
88 SR 0
12 132 157 0.35 76 PCT 12 P2 VS1 0.9 TEH TEC 0.61 CBAY2 228 C
66 0
12 132 157 0.42 98 PCT 14 P2 VS2
-0.74 TEH TEC 0.61 CBAY2 228 C
66 0
12 142 157 0.69 124 PCT 15 P2 11H 0.68 VS3 TEH 0.61 CBAY2 49 H
56 0
12 142 157 0.44 73 PCT 12 P2 BW1
-0.85 VS3 TEH 0.61 CBAY2 49 H
56 0
12 142 157 0.44 116 PCT 12 P2 VS3
-1.05 VS3 TEH 0.61 CBAY2 49 H
56 0
12 144 157 0.28 144 PCT 9
P2 11H
-1.06 VS3 TEH 0.61 CBAY2 49 H
57 0
SG 12 Summary Data Sheets Page 29 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 144 157 1.53 95 PCT 27 P2 VS3
-1.05 VS3 TEH 0.61 CBAY2 49 H
57 0
12 144 157 0.46 35 PCT 10 P2 03C
-0.93 VS3 TEC 0.61 CBAY2 54 C
77 0
12 144 157 0.82 69 WAR 17 P7 11H
-1.06 VS3 TEH 0.61 NYAX2 61 H
79 0
12 144 157 2.2 98 WAR 27 0.25 P30 VS3
-0.99 VS3 TEH 0.61 NYAX2 61 H
79 T
0 12 67 158 0.24 105 PCT 10 P2 VS3
-0.76 TEH TEC 0.61 CBAY2 230 C
5 0
12 67 158 0.21 126 PCT 9
P2 08C 0.74 TEH TEC 0.61 CBAY2 230 C
5 0
12 71 158 0.19 70 PCT 8
P2 VS2
-0.75 TEH TEC 0.61 CBAY2 230 C
33 0
12 71 158 0.25 163 PCT 10 P2 VS4 0.98 TEH TEC 0.61 CBAY2 230 C
33 0
12 73 158 0.39 136 PCT 14 P2 VS2
-0.78 TEH TEC 0.61 CBAY2 230 C
30 0
12 75 158 0.43 136 PCT 12 P2 08H 0.63 TEH TEC 0.61 CBAY2 230 C
29 0
12 81 158 0.38 120 PCT 14 P2 VS2
-0.97 TEH TEC 0.61 CBAY2 230 C
26 0
12 81 158 0.35 95 PCT 13 P2 09C
-0.98 TEH TEC 0.61 CBAY2 230 C
26 0
12 117 158 0.28 137 PCT 10 P2 BW2 0.97 TEH TEC 0.61 CBAY2 226 C
67 0
12 119 158 0.32 148 PCT 11 P2 BW2 0.92 TEH TEC 0.61 CBAY2 226 C
66 0
12 125 158 0.27 136 PCT 10 P2 VS1
-0.64 TEH TEC 0.61 CBAY2 226 C
63 0
12 129 158 0.31 148 PCT 11 P2 BW2
-0.8 TEH TEC 0.61 CBAY2 226 C
61 0
12 129 158 2.78 49 DEP 8
TSC 0.18 01C TEC 0.61 NYAX2 274 C
38 0
12 137 158 0.26 117 PCT 9
P2 VS3
-0.94 TEH TEC 0.61 CBAY2 224 C
97 0
12 10 159 0.22 99 PCT 8
P2 BW2
-0.53 TEH TEC 0.61 CBAY2 204 C
18 0
12 30 159 0.37 51 PCT 12 P2 BW2 0.96 TEH TEC 0.61 CBAY2 216 C
6 0
12 42 159 0.3 60 PCT 10 P2 BW2 1.16 TEH TEC 0.61 CBAY2 212 C
380 0
12 48 159 0.43 79 PCT 12 P2 09C
-1.22 TEH TEC 0.61 CBAY2 212 C
377 0
12 56 159 0.41 119 PCT 12 P2 VS3
-0.9 TEH TEC 0.61 CBAY2 212 C
373 0
12 60 159 0.36 112 PCT 11 P2 BW1 0.94 TEH TEC 0.61 CBAY2 212 C
371 0
12 62 159 0.53 103 PCT 15 P2 VS3
-0.89 TEH TEC 0.61 CBAY2 212 C
370 0
12 64 159 0.23 53 PCT 8
P2 VS3
-0.68 TEH TEC 0.61 CBAY2 212 C
369 0
12 72 159 0.32 148 PCT 11 P2 VS2
-0.87 TEH TEC 0.61 CBAY2 226 C
132 0
12 80 159 0.27 80 PCT 10 P2 BW1
-0.83 TEH TEC 0.61 CBAY2 226 C
128 0
12 112 159 0.38 148 PCT 13 P2 BW1 1.09 TEH TEC 0.61 CBAY2 226 C
46 0
12 114 159 0.43 154 PCT 14 P2 VS1 0.86 TEH TEC 0.61 CBAY2 226 C
47 0
12 132 159 0.3 157 PCT 11 P2 BW2 0.65 TEH TEC 0.61 CBAY2 226 C
56 0
12 140 159 0.33 118 PCT 13 P2 BW1
-0.87 TEH TEC 0.61 CBAY2 222 C
103 0
12 140 159 0.12 57 DSI P1 04C
-0.93 TEH TEC 0.61 CBAY2 222 C
103 0
12 140 159 0.19 110 WAR 8
P30 04C
-0.73 11C TEC 0.61 NYAX2 264 C
89 0
12 35 160 0.26 45 PCT 10 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 214 C
27 0
12 37 160 0.41 64 PCT 14 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 214 C
28 0
12 37 160 0.37 130 PCT 13 P2 BW1 0.94 TEH TEC 0.61 CBAY2 214 C
28 0
12 57 160 0.27 83 PCT 10 P2 VS3 1.02 TEH TEC 0.61 CBAY2 214 C
38 0
12 59 160 0.28 46 PCT 11 P2 BW1 0.75 TEH TEC 0.61 CBAY2 214 C
39 0
12 65 160 0.35 131 PCT 12 P2 BW1
-0.24 TEH TEC 0.61 CBAY2 228 C
116 0
12 67 160 0.35 124 PCT 12 P2 BW1 0.92 TEH TEC 0.61 CBAY2 228 C
117 0
12 77 160 0.3 78 PCT 11 P2 VS4 0.92 TEH TEC 0.61 CBAY2 228 C
122 0
12 79 160 0.41 125 PCT 14 P2 VS2
-0.69 TEH TEC 0.61 CBAY2 228 C
123 0
12 81 160 0.46 130 PCT 15 P2 VS4 1.08 TEH TEC 0.61 CBAY2 228 C
124 0
12 85 160 0.42 109 PCT 14 P2 VS2
-0.73 TEH TEC 0.61 CBAY2 228 C
126 0
12 97 160 0.28 81 PCT 10 P2 BW1 1.02 TEH TEC 0.61 CBAY2 228 C
132 0
12 125 160 0.4 110 PCT 14 P2 BW1 0.44 TEH TEC 0.61 CBAY2 228 C
47 0
12 125 160 0.34 76 PCT 12 P2 VS1
-0.71 TEH TEC 0.61 CBAY2 228 C
47 0
SG 12 Summary Data Sheets Page 30 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 129 160 0.41 124 PCT 12 P2 VS1 0.67 VS3 TEH 0.61 CBAY2 49 H
54 0
12 129 160 0.44 54 PCT 12 P2 VS3
-0.98 VS3 TEH 0.61 CBAY2 49 H
54 0
12 129 160 0.33 104 PCT 11 P2 BW2
-0.91 VS3 TEC 0.61 CBAY2 252 C
7 0
12 133 160 0.3 136 PCT 10 P2 VS5
-0.72 TEH TEC 0.61 CBAY2 224 C
92 0
12 44 161 0.3 118 PCT 11 P2 BW1
-0.9 TEH TEC 0.61 CBAY2 214 C
52 0
12 48 161 1.22 100 PCT 27 P2 09C
-1.6 TEH TEC 0.61 CBAY2 214 C
50 0
12 48 161 1.85 93 WAR 25 0.14 P3 09C
-1.99 09C TEC 0.61 NYAX2 264 C
78 F
0 12 60 161 0.25 80 PCT 10 P2 BW2 0.87 TEH TEC 0.61 CBAY2 214 C
44 0
12 66 161 0.26 138 PCT 10 P2 VS3
-0.7 TEH TEC 0.61 CBAY2 228 C
115 0
12 76 161 0.41 58 PCT 14 P2 VS2 0.85 TEH TEC 0.61 CBAY2 228 C
110 0
12 86 161 0.33 102 PCT 12 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 228 C
105 0
12 92 161 0.49 65 PCT 15 P2 BW2
-0.76 TEH TEC 0.61 CBAY2 228 C
102 0
12 114 161 0.28 120 PCT 10 P2 VS4
-0.62 TEH TEC 0.61 CBAY2 228 C
27 0
12 128 161 0.4 87 PCT 12 P2 VS4
-0.73 VS3 TEC 0.61 CBAY2 252 C
6 0
12 132 161 0.5 128 PCT 14 P2 BW2 0.34 TEH TEC 0.61 CBAY2 224 C
90 0
12 138 161 0.25 126 PCT 10 P2 VS3 0.82 TEH TEC 0.61 CBAY2 222 C
99 0
12 19 162 0.25 134 PCT 9
P2 BW1
-0.8 TEH TEC 0.61 CBAY2 216 C
19 0
12 21 162 0.32 107 PCT 11 P2 VS3
-0.9 TEH TEC 0.61 CBAY2 216 C
20 0
12 35 162 0.27 63 PCT 10 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 216 C
27 0
12 35 162 0.28 40 PCT 10 P2 BW1 0.83 TEH TEC 0.61 CBAY2 216 C
27 0
12 75 162 10.99 93 PLP 76 TSH 0.68 01H TEH 0.61 NYAX2 61 H
23 SR 0
12 83 162 0.51 144 PCT 11 P2 09H 0.87 TEH TEC 0.61 CBAY2 226 C
108 0
12 83 162 0.27 146 PCT 10 P2 VS2
-0.66 TEH TEC 0.61 CBAY2 226 C
108 0
12 85 162 0.38 151 PCT 13 P2 VS4 0.83 TEH TEC 0.61 CBAY2 226 C
109 0
12 87 162 0.22 151 PCT 8
P2 VS2
-0.71 TEH TEC 0.61 CBAY2 226 C
110 0
12 89 162 0.32 135 PCT 11 P2 BW2 0.88 TEH TEC 0.61 CBAY2 226 C
111 0
12 91 162 0.27 145 PCT 10 P2 BW1 0.47 TEH TEC 0.61 CBAY2 226 C
112 0
12 99 162 0.34 104 PCT 12 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 226 C
116 0
12 99 162 0.27 111 PCT 10 P2 BW1 0.93 TEH TEC 0.61 CBAY2 226 C
116 0
12 101 162 0.26 125 PCT 10 P2 BW1 0.93 TEH TEC 0.61 CBAY2 226 C
117 0
12 105 162 0.22 145 PCT 8
P2 VS2
-0.8 TEH TEC 0.61 CBAY2 226 C
28 0
12 111 162 0.18 122 PCT 7
P2 VS2
-0.73 TEH TEC 0.61 CBAY2 226 C
30 0
12 115 162 0.27 133 PCT 10 P2 BW1 0.36 TEH TEC 0.61 CBAY2 226 C
32 0
12 125 162 0.28 126 PCT 10 P2 VS2
-0.89 TEH TEC 0.61 CBAY2 226 C
37 0
12 129 162 0.19 140 PCT 7
P2 VS1 0.8 TEH TEC 0.61 CBAY2 224 C
87 0
12 129 162 0.4 99 PCT 12 P2 VS4
-0.82 TEH TEC 0.61 CBAY2 224 C
87 0
12 135 162 0.29 58 PCT 10 P2 03C
-0.9 TEH TEC 0.61 CBAY2 222 C
96 0
12 44 163 0.36 146 PCT 12 P2 BW1
-0.79 TEH TEC 0.61 CBAY2 216 C
53 0
12 50 163 0.32 146 PCT 11 P2 BW1
-0.73 TEH TEC 0.61 CBAY2 216 C
50 0
12 50 163 0.32 36 PCT 11 P2 BW2
-0.75 TEH TEC 0.61 CBAY2 216 C
50 0
12 54 163 0.31 94 PCT 11 P2 BW1 1.48 TEH TEC 0.61 CBAY2 216 C
48 0
12 60 163 0.33 67 PCT 11 P2 BW1
-0.85 TEH TEC 0.61 CBAY2 216 C
45 0
12 76 163 20.72 110 PLP 152 TSH 0.86 01H TEH 0.61 NYAX2 61 H
27 HR 0
12 76 163 2.93 54 PLP 7
TSH 0.82 TEH TEC 0.61 CBAY2 226 C
96 HR 0
12 92 163 0.35 144 PCT 12 P2 BW2
-0.9 TEH TEC 0.61 CBAY2 226 C
88 0
12 108 163 0.35 122 PCT 12 P2 BW2
-1.67 TEH TEC 0.61 CBAY2 226 C
23 0
12 120 163 0.38 116 PCT 13 P2 VS3 0.89 TEH TEC 0.61 CBAY2 226 C
17 0
12 134 163 2.44 180 DNT P1 10H 9.51 TEH TEC 0.61 CBAY2 222 C
94 0
SG 12 Summary Data Sheets Page 31 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 134 163 3.67 180 DNT P1 10H 10.14 TEH TEC 0.61 CBAY2 222 C
94 0
12 134 163 2.98 180 DNT P1 10H 17.51 TEH TEC 0.61 CBAY2 222 C
94 0
12 5
164 0.38 122 PCT 12 P2 BW1
-0.54 TEH TEC 0.61 CBAY2 204 C
23 0
12 37 164 0.42 130 PCT 14 P2 BW1 0.73 TEH TEC 0.61 CBAY2 214 C
82 0
12 43 164 0.21 129 PCT 8
P2 BW1 0.91 TEH TEC 0.61 CBAY2 214 C
85 0
12 63 164 0.3 123 PCT 11 P2 BW1
-1.01 TEH TEC 0.61 CBAY2 214 C
95 0
12 83 164 0.16 38 PCT 7
P2 08C
-0.97 TEH TEC 0.61 CBAY2 228 C
20 0
12 87 164 0.28 75 PCT 11 P2 VS2
-0.8 TEH TEC 0.61 CBAY2 228 C
18 0
12 87 164 0.25 105 PCT 10 P2 VS3
-0.85 TEH TEC 0.61 CBAY2 228 C
18 0
12 91 164 0.47 113 PCT 15 P2 BW1 0.85 TEH TEC 0.61 CBAY2 228 C
16 0
12 93 164 0.3 76 PCT 11 P2 VS2
-0.83 TEH TEC 0.61 CBAY2 228 C
15 0
12 97 164 0.59 103 PCT 17 P2 VS3
-0.82 TEH TEC 0.61 CBAY2 228 C
12 0
12 101 164 0.27 74 PCT 10 P2 BW1 0.49 TEH TEC 0.61 CBAY2 228 C
8 0
12 103 164 0.32 110 PCT 12 P2 BW1 0.92 TEH TEC 0.61 CBAY2 228 C
7 0
12 103 164 0.26 46 PCT 10 P2 BW2 1
TEH TEC 0.61 CBAY2 228 C
7 0
12 111 164 3.87 274 WAR 35 0.41 P30 VS3
-0.57 VS3 TEH 0.61 NYAX2 61 H
36 T
0 12 111 164 1.68 107 PCT 30 P2 VS3
-0.84 TEH TEC 0.61 CBAY2 224 C
271 0
12 125 164 0.3 58 PCT 10 P2 BW1 0.74 TEH TEC 0.61 CBAY2 224 C
264 0
12 125 164 0.3 93 PCT 10 P2 VS3
-0.83 TEH TEC 0.61 CBAY2 224 C
264 0
12 127 164 0.34 72 PCT 11 P2 BW1 1.08 TEH TEC 0.61 CBAY2 224 C
82 0
12 133 164 0.25 117 PCT 10 P2 BW1
-0.03 TEH TEC 0.61 CBAY2 222 C
92 0
12 8
165 0.25 146 PCT 10 P2 BW1
-0.76 TEH TEC 0.61 CBAY2 202 C
48 0
12 48 165 0.31 115 PCT 11 P2 BW1
-0.74 TEH TEC 0.61 CBAY2 214 C
104 0
12 48 165 0.52 116 PCT 16 P2 09C
-1.66 TEH TEC 0.61 CBAY2 214 C
104 14 0
12 64 165 0.3 109 PCT 11 P2 09C 0.58 TEH TEC 0.61 CBAY2 214 C
96 0
12 70 165 0.24 61 PCT 8
P2 VS2
-0.7 TEH TEC 0.61 CBAY2 224 C
236 0
12 72 165 0.32 100 PCT 10 P2 VS2
-0.79 TEH TEC 0.61 CBAY2 224 C
237 0
12 74 165 0.24 119 PCT 8
P2 VS2
-0.79 TEH TEC 0.61 CBAY2 224 C
238 0
12 82 165 0.27 43 PCT 9
P2 VS2
-0.77 TEH TEC 0.61 CBAY2 224 C
242 0
12 82 165 0.41 100 PCT 12 P2 VS4 0.4 TEH TEC 0.61 CBAY2 224 C
242 0
12 96 165 0.35 126 PCT 11 P2 BW2
-0.89 TEH TEC 0.61 CBAY2 224 C
249 0
12 100 165 0.38 34 PCT 12 P2 BW1 0.41 TEH TEC 0.61 CBAY2 224 C
251 0
12 124 165 0.22 315 PCT 8
P2 VS4
-0.81 TEH TEC 0.61 CBAY2 224 C
263 0
12 128 165 0.43 95 PCT 13 P2 VS2
-0.82 TEH TEC 0.61 CBAY2 224 C
81 0
12 134 165 0.5 101 PCT 17 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 222 C
90 0
12 134 165 0.28 100 PCT 11 P2 VS3
-0.73 TEH TEC 0.61 CBAY2 222 C
90 0
12 134 165 0.6 81 MBM 6
VS4 16 TEH TEC 0.61 CBAY2 222 C
90 0
12 47 166 0.31 117 PCT 11 P2 VS3
-0.76 TEH TEC 0.61 CBAY2 216 C
88 0
12 59 166 0.32 58 PCT 11 P2 BW1 0.94 TEH TEC 0.61 CBAY2 216 C
94 0
12 77 166 0.37 148 PCT 13 P2 VS2 0.8 TEH TEC 0.61 CBAY2 226 C
81 0
12 81 166 0.35 93 PCT 12 P2 VS3
-1.18 TEH TEC 0.61 CBAY2 226 C
83 0
12 83 166 0.24 146 PCT 9
P2 VS2
-0.71 TEH TEC 0.61 CBAY2 226 C
13 0
12 89 166 0.31 129 PCT 11 P2 BW1 1.07 TEH TEC 0.61 CBAY2 226 C
10 0
12 97 166 0.43 115 PCT 14 P2 BW1 0.9 TEH TEC 0.61 CBAY2 228 C
10 0
12 99 166 0.35 47 PCT 12 P2 BW1 1.02 TEH TEC 0.61 CBAY2 228 C
9 0
12 105 166 0.27 143 PCT 10 P2 BW2
-0.53 TEH TEC 0.61 CBAY2 226 C
6 0
12 107 166 0.99 108 WAR 19 P31 VS2
-0.86 VS3 TEH 0.61 NYAX2 61 H
40 0
12 107 166 2.01 90 WAR 27 0.29 P30 VS3
-0.9 VS3 TEH 0.61 NYAX2 61 H
40 F
0 SG 12 Summary Data Sheets Page 32 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 107 166 0.33 135 PCT 12 P2 VS2
-0.96 TEH TEC 0.61 CBAY2 226 C
5 0
12 107 166 0.92 117 PCT 23 P2 VS3
-0.92 TEH TEC 0.61 CBAY2 226 C
5 0
12 107 166 0.21 146 PCT 8
P2 VS4 1.05 TEH TEC 0.61 CBAY2 226 C
5 0
12 109 166 0.24 62 PCT 10 P2 VS3
-0.92 TEH TEC 0.61 CBAY2 222 C
255 0
12 111 166 2.82 94 WAR 30 0.39 P30 VS3
-0.87 VS3 TEH 0.61 NYAX2 61 H
41 T
0 12 111 166 1.31 116 PCT 29 P2 VS3
-0.93 TEH TEC 0.61 CBAY2 222 C
254 0
12 111 166 0.31 152 PCT 12 P2 BW2
-0.87 TEH TEC 0.61 CBAY2 222 C
254 0
12 121 166 0.23 62 PCT 10 P2 VS3
-0.8 TEH TEC 0.61 CBAY2 222 C
249 0
12 129 166 0.17 141 PCT 7
P2 VS5
-0.59 TEH TEC 0.61 CBAY2 222 C
86 0
12 131 166 0.41 96 PCT 15 P2 VS3
-0.89 TEH TEC 0.61 CBAY2 222 C
87 0
12 38 167 0.29 126 PCT 10 P2 BW1 1
TEH TEC 0.61 CBAY2 216 C
112 0
12 48 167 0.36 72 PCT 12 P2 09C
-1.14 TEH TEC 0.61 CBAY2 216 C
107 0
12 58 167 0.26 58 PCT 9
P2 BW1
-0.87 TEH TEC 0.61 CBAY2 216 C
102 0
12 60 167 0.27 32 PCT 9
P2 09C
-0.98 TEH TEC 0.61 CBAY2 216 C
101 0
12 70 167 0.54 117 PCT 17 P2 VS2
-0.85 TEH TEC 0.61 CBAY2 222 C
223 0
12 74 167 0.32 139 PCT 12 P2 BW1
-0.79 TEH TEC 0.61 CBAY2 222 C
225 0
12 76 167 0.25 110 PCT 10 P2 VS2
-0.84 TEH TEC 0.61 CBAY2 222 C
226 0
12 76 167 0.31 129 PCT 12 P2 VS2 0.75 TEH TEC 0.61 CBAY2 222 C
226 0
12 76 167 0.23 92 PCT 10 P2 VS3
-0.76 TEH TEC 0.61 CBAY2 222 C
226 0
12 76 167 0.21 39 PCT 9
P2 08C
-1.04 TEH TEC 0.61 CBAY2 222 C
226 0
12 78 167 0.29 64 PCT 11 P2 BW1 0.94 TEH TEC 0.61 CBAY2 222 C
227 0
12 86 167 0.23 147 PCT 10 P2 VS4
-0.64 TEH TEC 0.61 CBAY2 222 C
231 0
12 94 167 0.27 116 PCT 11 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 222 C
235 0
12 96 167 0.3 141 PCT 12 P2 VS3 0.89 TEH TEC 0.61 CBAY2 222 C
236 0
12 114 167 0.27 85 PCT 11 P2 VS1
-0.78 TEH TEC 0.61 CBAY2 222 C
245 0
12 128 167 NDF P11 10H
-0.98 10H TEH 0.61 NYAX2 61 H
78 0
12 128 167 0.14 100 DSI P1 10H
-0.98 TEH TEC 0.61 CBAY2 222 C
84 0
12 128 167 0.23 116 PCT 10 P2 VS3
-0.72 TEH TEC 0.61 CBAY2 222 C
84 0
12 130 167 0.28 100 PCT 11 P2 VS3
-0.99 TEH TEC 0.61 CBAY2 222 C
85 0
12 27 168 NDF P7 VS3 1.4 VS3 TEH 0.61 NYAX2 61 H
42 0
12 27 168 3.9 180 DNT P1 VS3 1.4 TEH TEC 0.61 CBAY2 214 C
133 0
12 41 168 0.26 117 PCT 10 P2 BW1 0.92 TEH TEC 0.61 CBAY2 214 C
140 0
12 59 168 0.22 91 PCT 9
P2 09C 0.76 TEH TEC 0.61 CBAY2 214 C
149 0
12 77 168 0.28 47 PCT 9
P2 BW1 0.93 TEH TEC 0.61 CBAY2 224 C
227 0
12 85 168 0.21 34 PCT 7
P2 VS3
-0.92 TEH TEC 0.61 CBAY2 224 C
223 0
12 89 168 0.27 60 PCT 9
P2 BW1 0.62 TEH TEC 0.61 CBAY2 224 C
221 0
12 99 168 0.32 104 PCT 11 P2 BW1 0.92 TEH TEC 0.61 CBAY2 232 C
49 0
12 111 168 0.73 123 PCT 18 P2 VS3
-1.01 TEH TEC 0.61 CBAY2 224 C
210 0
12 117 168 0.23 79 PCT 8
P2 BW1 0.95 TEH TEC 0.61 CBAY2 224 C
207 0
12 127 168 0.24 43 PCT 10 P2 BW2 0.91 TEH TEC 0.61 CBAY2 222 C
82 0
12 48 169 0.26 45 PCT 10 P2 VS3
-0.81 TEH TEC 0.61 CBAY2 214 C
160 0
12 52 169 0.34 130 PCT 12 P2 BW1
-0.65 TEH TEC 0.61 CBAY2 214 C
158 0
12 52 169 0.24 44 PCT 9
P2 VS3
-0.85 TEH TEC 0.61 CBAY2 214 C
158 0
12 72 169 0.6 152 PCT 10 P2 09H 0.72 TEH TEC 0.61 CBAY2 224 C
182 0
12 74 169 0.78 115 PCT 19 P2 VS4 0.72 TEH TEC 0.61 CBAY2 224 C
183 0
12 74 169 1.87 125 WAR 26 0.63 P27 VS4 1.01 VS3 TEC 0.61 NYAX2 264 C
83 T
0 12 76 169 0.24 68 PCT 8
P2 VS2 0.8 TEH TEC 0.61 CBAY2 224 C
184 0
12 106 169 0.32 106 PCT 10 P2 BW1
-1.27 TEH TEC 0.61 CBAY2 224 C
199 0
SG 12 Summary Data Sheets Page 33 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 106 169 0.44 104 PCT 13 P2 BW2
-1.51 TEH TEC 0.61 CBAY2 224 C
199 0
12 126 169 0.26 60 PCT 11 P2 BW2
-0.9 TEH TEC 0.61 CBAY2 222 C
79 0
12 128 169 2.57 175 DNT P1 TSH 5.75 TEH TEC 0.61 CBAY2 222 C
80 0
12 128 169 0.43 92 PCT 15 P2 VS3
-1.06 TEH TEC 0.61 CBAY2 222 C
80 0
12 51 170 0.3 105 PCT 11 P2 BW1
-0.69 TEH TEC 0.61 CBAY2 216 C
148 0
12 71 170 0.38 125 PCT 14 P2 BW2 0.84 TEH TEC 0.61 CBAY2 222 C
219 0
12 73 170 0.29 53 PCT 11 P2 BW2
-0.77 TEH TEC 0.61 CBAY2 222 C
218 0
12 75 170 0.36 139 PCT 13 P2 VS2 0.78 TEH TEC 0.61 CBAY2 222 C
217 0
12 77 170 0.25 102 PCT 10 P2 BW1 1.1 TEH TEC 0.61 CBAY2 222 C
216 0
12 77 170 0.24 114 PCT 10 P2 VS3
-0.8 TEH TEC 0.61 CBAY2 222 C
216 0
12 99 170 0.28 131 PCT 11 P2 BW1 0.91 TEH TEC 0.61 CBAY2 222 C
205 0
12 111 170 0.29 76 PCT 12 P2 BW1 0.95 TEH TEC 0.61 CBAY2 222 C
199 0
12 113 170 0.23 85 PCT 10 P2 VS3
-0.77 TEH TEC 0.61 CBAY2 222 C
198 0
12 121 170 0.18 130 PCT 6
P2 BW2 0.9 TEH TEC 0.61 CBAY2 224 C
69 0
12 125 170 1.9 87 WAR 26 0.35 P22 VS3 0.49 VS3 TEH 0.61 NYAX2 61 H
77 T
0 12 125 170 0.65 127 PCT 20 P2 VS3 0.49 TEH TEC 0.61 CBAY2 222 C
77 0
12 48 171 0.41 68 PCT 12 P2 09C
-1.11 TEH TEC 0.61 CBAY2 216 C
165 0
12 50 171 0.39 61 PCT 13 P2 BW1
-0.72 TEH TEC 0.61 CBAY2 216 C
164 0
12 62 171 0.18 38 PCT 7
P2 VS3
-0.77 TEH TEC 0.61 CBAY2 216 C
158 0
12 84 171 0.37 106 PCT 14 P2 VS2
-0.79 TEH TEC 0.61 CBAY2 222 C
181 0
12 102 171 0.32 93 PCT 12 P2 BW1
-0.86 TEH TEC 0.61 CBAY2 222 C
190 0
12 110 171 0.36 100 PCT 13 P2 VS3
-0.83 TEH TEC 0.61 CBAY2 222 C
194 0
12 114 171 0.27 36 PCT 11 P2 VS1
-0.89 TEH TEC 0.61 CBAY2 222 C
196 0
12 120 171 0.67 102 PCT 17 P2 VS3
-0.94 TEH TEC 0.61 CBAY2 224 C
66 0
12 122 171 2.02 87 WAR 27 0.43 P30 VS3
-0.94 VS3 TEH 0.61 NYAX2 61 H
76 T
0 12 122 171 1.02 105 PCT 26 P2 VS3
-1 TEH TEC 0.61 CBAY2 222 C
74 0
12 35 172 0.38 79 PCT 13 P2 BW1 1.01 TEH TEC 0.61 CBAY2 214 C
191 0
12 39 172 0.32 52 PCT 12 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 214 C
193 0
12 53 172 0.29 66 PCT 11 P2 BW1
-0.93 TEH TEC 0.61 CBAY2 214 C
200 0
12 65 172 0.28 114 PCT 9
P2 VS3
-0.73 TEH TEC 0.61 CBAY2 224 C
177 0
12 77 172 0.28 41 PCT 9
P2 BW1 0.91 TEH TEC 0.61 CBAY2 224 C
171 0
12 81 172 0.31 86 PCT 10 P2 BW2
-0.43 TEH TEC 0.61 CBAY2 224 C
169 0
12 81 172 0.37 64 PCT 12 P2 BW2 0.96 TEH TEC 0.61 CBAY2 224 C
169 0
12 83 172 0.25 78 PCT 8
P2 VS2
-0.75 TEH TEC 0.61 CBAY2 224 C
168 0
12 83 172 0.38 95 PCT 12 P2 BW2 0.26 TEH TEC 0.61 CBAY2 224 C
168 0
12 87 172 0.14 118 PCT 5
P2 VS3
-0.28 TEH TEC 0.61 CBAY2 224 C
166 0
12 105 172 0.36 121 PCT 11 P2 BW1 1.19 TEH TEC 0.61 CBAY2 224 C
157 0
12 111 172 0.42 97 PCT 13 P2 VS3
-0.89 TEH TEC 0.61 CBAY2 224 C
154 0
12 111 172 0.3 79 PCT 10 P2 VS4 0.98 TEH TEC 0.61 CBAY2 224 C
154 0
12 113 172 0.33 111 PCT 10 P2 BW1
-0.83 TEH TEC 0.61 CBAY2 224 C
61 0
12 121 172 0.28 95 PCT 11 P2 10H
-0.25 TEH TEC 0.61 CBAY2 222 C
72 0
12 123 172 0.19 120 PCT 8
P2 VS3 0.9 TEH TEC 0.61 CBAY2 222 C
73 0
12 16 173 0.2 42 PCT 8
P2 08H
-0.74 TEH TEC 0.61 CBAY2 214 C
230 0
12 26 173 0.29 136 PCT 11 P2 BW2 0.95 TEH TEC 0.61 CBAY2 214 C
225 0
12 60 173 0.23 124 PCT 9
P2 VS3
-0.92 TEH TEC 0.61 CBAY2 214 C
208 0
12 98 173 0.63 104 PCT 17 P2 VS3
-1.08 TEH TEC 0.61 CBAY2 224 C
147 0
12 104 173 0.34 108 PCT 11 P2 BW1
-0.91 TEH TEC 0.61 CBAY2 224 C
150 0
12 106 173 0.19 93 PCT 7
P2 VS3 0.96 TEH TEC 0.61 CBAY2 224 C
151 0
SG 12 Summary Data Sheets Page 34 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 108 173 0.34 101 PCT 11 P2 BW1
-1.85 TEH TEC 0.61 CBAY2 224 C
152 0
12 108 173 0.23 74 PCT 8
P2 VS3 0.79 TEH TEC 0.61 CBAY2 224 C
152 0
12 110 173 0.43 53 PCT 13 P2 BW1 1.59 TEH TEC 0.61 CBAY2 224 C
153 0
12 114 173 0.12 100 NQI 3
TSC 6.57 TEH TEC 0.61 CBAY2 224 C
59 0
12 114 173 NDF P37 TSC 6.57 01C TEC 0.61 NYAX2 264 C
85 0
12 118 173 0.33 125 PCT 13 P2 VS3 0.92 TEH TEC 0.61 CBAY2 222 C
68 0
12 122 173 0.58 112 PCT 18 P2 VS3
-0.95 TEH TEC 0.61 CBAY2 222 C
70 0
12 122 173 0.62 114 PCT 19 P2 VS3 0.85 TEH TEC 0.61 CBAY2 222 C
70 0
12 57 174 0.24 89 PCT 9
P2 VS3
-0.8 TEH TEC 0.61 CBAY2 216 C
207 0
12 59 174 0.42 125 PCT 13 P2 BW1 0.69 TEH TEC 0.61 CBAY2 216 C
208 0
12 75 174 0.16 78 PCT 7
P2 VS2 0.86 TEH TEC 0.61 CBAY2 222 C
167 0
12 101 174 0.37 134 PCT 14 P2 BW1
-0.86 TEH TEC 0.61 CBAY2 222 C
154 0
12 103 174 0.22 141 PCT 9
P2 BW2 0.81 TEH TEC 0.61 CBAY2 222 C
153 0
12 105 174 0.3 125 PCT 12 P2 VS3
-1.01 TEH TEC 0.61 CBAY2 222 C
152 0
12 107 174 0.41 108 PCT 15 P2 VS3
-1 TEH TEC 0.61 CBAY2 222 C
151 0
12 113 174 0.23 141 PCT 8
P2 VS3
-0.76 TEH TEC 0.61 CBAY2 224 C
57 0
12 32 175 0.3 38 PCT 10 P2 VS3
-0.52 TEH TEC 0.61 CBAY2 216 C
229 0
12 60 175 0.28 79 PCT 10 P2 08C 0.81 TEH TEC 0.61 CBAY2 216 C
215 0
12 70 175 0.25 58 PCT 10 P2 VS3 0.87 TEH TEC 0.61 CBAY2 222 C
131 0
12 80 175 0.67 93 PCT 20 P2 BW2 0.81 TEH TEC 0.61 CBAY2 222 C
136 0
12 80 175 1.16 134 WAR 21 0.52 P22 BW2 0.85 VS3 TEC 0.61 NYAX2 264 C
84 T
0 12 86 175 0.26 109 PCT 11 P2 VS4
-0.49 TEH TEC 0.61 CBAY2 222 C
139 0
12 88 175 0.26 139 PCT 11 P2 VS2 0.82 TEH TEC 0.61 CBAY2 222 C
140 0
12 88 175 0.48 122 PCT 16 P2 VS3 0.84 TEH TEC 0.61 CBAY2 222 C
140 0
12 98 175 0.26 108 PCT 10 P2 VS4
-0.75 TEH TEC 0.61 CBAY2 222 C
145 0
12 114 175 0.21 75 PCT 9
P2 BW2
-0.88 TEH TEC 0.61 CBAY2 222 C
62 0
12 116 175 0.24 46 PCT 10 P2 BW1
-0.82 TEH TEC 0.61 CBAY2 222 C
63 0
12 116 175 0.36 124 PCT 13 P2 VS3
-1.03 TEH TEC 0.61 CBAY2 222 C
63 0
12 87 176 0.38 123 PCT 12 P2 VS2
-0.77 TEH TEC 0.61 CBAY2 224 C
119 0
12 103 176 0.19 85 PCT 7
P2 VS2
-0.65 TEH TEC 0.61 CBAY2 224 C
46 0
12 115 176 0.29 107 PCT 12 P2 BW1 0.85 TEH TEC 0.61 CBAY2 222 C
61 0
12 44 177 0.31 103 PCT 11 P2 BW1
-0.78 TEH TEC 0.61 CBAY2 214 C
268 0
12 54 177 0.3 131 PCT 11 P2 BW1
-1.18 TEH TEC 0.61 CBAY2 214 C
263 0
12 76 177 0.35 138 PCT 11 P2 BW2 0.74 TEH TEC 0.61 CBAY2 224 C
105 0
12 82 177 0.39 112 PCT 12 P2 VS3 0.8 TEH TEC 0.61 CBAY2 224 C
108 0
12 84 177 0.34 114 PCT 11 P2 VS2 0.82 TEH TEC 0.61 CBAY2 224 C
109 0
12 86 177 0.25 143 PCT 9
P2 VS2 0.87 TEH TEC 0.61 CBAY2 224 C
110 0
12 88 177 0.25 109 PCT 9
P2 VS2 0.84 TEH TEC 0.61 CBAY2 224 C
111 0
12 94 177 0.4 48 PCT 12 P2 BW1
-0.69 TEH TEC 0.61 CBAY2 224 C
113 0
12 96 177 0.3 95 PCT 10 P2 BW1
-0.83 TEH TEC 0.61 CBAY2 224 C
114 0
12 108 177 0.27 86 PCT 9
P2 BW2
-0.82 TEH TEC 0.61 CBAY2 224 C
51 0
12 110 177 0.26 111 PCT 11 P2 VS2
-0.69 TEH TEC 0.61 CBAY2 222 C
57 0
12 55 178 0.27 24 PCT 10 P2 BW1 1.27 TEH TEC 0.61 CBAY2 216 C
262 0
12 59 178 0.41 145 PCT 13 P2 BW1 0.93 TEH TEC 0.61 CBAY2 216 C
264 0
12 75 178 0.24 106 PCT 10 P2 VS2
-0.83 TEH TEC 0.61 CBAY2 222 C
125 0
12 87 178 0.24 80 PCT 10 P2 BW2
-0.82 TEH TEC 0.61 CBAY2 222 C
119 0
12 89 178 0.28 144 PCT 11 P2 BW1 0.11 TEH TEC 0.61 CBAY2 222 C
118 0
12 97 178 0.23 62 PCT 10 P2 VS2
-0.81 TEH TEC 0.61 CBAY2 222 C
41 0
SG 12 Summary Data Sheets Page 35 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 99 178 0.26 107 PCT 11 P2 VS3
-1.11 TEH TEC 0.61 CBAY2 222 C
42 0
12 113 178 0.3 129 PCT 12 P2 VS3 0.82 TEH TEC 0.61 CBAY2 222 C
49 0
12 44 179 0.43 143 PCT 14 P2 BW2
-0.88 TEH TEC 0.61 CBAY2 216 C
277 0
12 48 179 0.8 134 PCT 17 P2 09C
-1.24 TEH TEC 0.61 CBAY2 216 C
275 0
12 52 179 0.35 135 PCT 12 P2 BW1
-0.81 TEH TEC 0.61 CBAY2 216 C
273 0
12 76 179 0.36 90 PCT 13 P2 VS2
-0.81 TEH TEC 0.61 CBAY2 222 C
110 0
12 76 179 0.43 110 PCT 15 P2 VS2 0.86 TEH TEC 0.61 CBAY2 222 C
110 0
12 86 179 0.25 115 PCT 10 P2 VS2 0.83 TEH TEC 0.61 CBAY2 222 C
115 0
12 88 179 0.34 123 PCT 13 P2 VS2 0.73 TEH TEC 0.61 CBAY2 222 C
116 0
12 90 179 0.23 31 PCT 10 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 222 C
117 0
12 35 180 0.26 35 PCT 10 P2 BW1 1.01 TEH TEC 0.61 CBAY2 214 C
296 0
12 39 180 0.32 90 PCT 12 P2 BW2
-0.89 TEH TEC 0.61 CBAY2 214 C
298 0
12 41 180 0.28 85 PCT 11 P2 BW2
-0.94 TEH TEC 0.61 CBAY2 214 C
299 0
12 51 180 0.33 101 PCT 11 P2 BW1 0.97 TEH TEC 0.61 CBAY2 220 C
5 0
12 53 180 0.31 51 PCT 10 P2 BW1
-1.05 TEH TEC 0.61 CBAY2 220 C
6 0
12 53 180 0.28 122 PCT 10 P2 VS3
-0.84 TEH TEC 0.61 CBAY2 220 C
6 0
12 55 180 0.28 90 PCT 10 P2 BW1 1.76 TEH TEC 0.61 CBAY2 220 C
7 0
12 73 180 0.34 143 PCT 11 P2 BW2 0.89 TEH TEC 0.61 CBAY2 224 C
31 0
12 77 180 0.21 56 PCT 7
P2 BW2
-0.74 TEH TEC 0.61 CBAY2 224 C
33 0
12 87 180 0.23 105 PCT 8
P2 VS2
-0.65 TEH TEC 0.61 CBAY2 224 C
38 0
12 97 180 0.37 114 PCT 12 P2 VS2
-0.86 TEH TEC 0.61 CBAY2 220 C
281 0
12 99 180 0.3 147 PCT 10 P2 VS2
-0.35 TEH TEC 0.61 CBAY2 220 C
282 0
12 109 180 0.47 114 PCT 16 P2 VS3
-0.98 TEH TEC 0.61 CBAY2 222 C
56 0
12 32 181 0.25 145 PCT 10 P2 BW1 0.91 TEH TEC 0.61 CBAY2 214 C
310 0
12 52 181 0.46 142 PCT 14 P2 BW1
-0.7 TEH TEC 0.61 CBAY2 220 C
20 0
12 70 181 0.2 72 PCT 7
P2 VS3
-0.78 TEH TEC 0.61 CBAY2 224 C
26 0
12 106 181 0.49 110 PCT 16 P2 VS3
-1.04 TEH TEC 0.61 CBAY2 218 C
287 0
12 49 182 0.34 110 PCT 11 P2 BW1 0.97 TEH TEC 0.61 CBAY2 216 C
313 0
12 51 182 0.3 89 PCT 10 P2 BW1 0.9 TEH TEC 0.61 CBAY2 216 C
314 0
12 59 182 0.26 132 PCT 10 P2 VS3 0.98 TEH TEC 0.61 CBAY2 218 C
8 0
12 85 182 0.39 118 PCT 14 P2 VS2
-0.83 TEH TEC 0.61 CBAY2 222 C
35 0
12 87 182 0.17 93 PCT 8
P2 VS4
-0.75 TEH TEC 0.61 CBAY2 222 C
36 0
12 89 182 0.4 82 PCT 14 P2 VS3
-0.91 TEH TEC 0.61 CBAY2 222 C
37 0
12 101 182 0.36 132 PCT 13 P2 VS3
-0.97 TEH TEC 0.61 CBAY2 218 C
282 0
12 103 182 1.27 76 WAR 21 0.22 P6 VS3
-0.98 VS3 TEH 0.61 NYAX2 61 H
75 T
0 12 103 182 0.69 115 PCT 20 P2 VS3
-0.96 TEH TEC 0.61 CBAY2 218 C
283 0
12 58 183 0.38 108 PCT 14 P2 VS3
-0.9 TEH TEC 0.61 CBAY2 218 C
14 0
12 76 183 0.52 132 PCT 17 P2 VS2
-0.82 TEH TEC 0.61 CBAY2 222 C
19 0
12 96 183 0.37 134 PCT 12 P2 VS3
-1.09 TEH TEC 0.61 CBAY2 220 C
269 0
12 98 183 0.26 113 PCT 11 P2 VS3
-0.99 TEH TEC 0.61 CBAY2 218 C
276 0
12 102 183 2.81 96 WAR 30 0.48 P6 VS3 0.92 VS3 TEH 0.61 NYAX2 61 H
73 T
0 12 102 183 1.16 127 PCT 27 P2 VS3 0.73 TEH TEC 0.61 CBAY2 218 C
278 0
12 102 183 0.28 102 PCT 11 P2 VS4
-0.72 TEH TEC 0.61 CBAY2 218 C
278 0
12 21 184 0.41 115 PCT 14 P2 BW2
-0.65 TEH TEC 0.61 CBAY2 214 C
326 0
12 27 184 NDF P1 VS3 1.11 VS3 TEH 0.61 NYAX2 61 H
70 0
12 27 184 2.97 181 DNT P1 VS3 1.11 TEH TEC 0.61 CBAY2 214 C
329 0
12 45 184 0.3 61 PCT 10 P2 BW1 0.98 TEH TEC 0.61 CBAY2 220 C
31 0
12 97 184 0.23 108 PCT 10 P2 VS3 0.86 TEH TEC 0.61 CBAY2 218 C
274 0
SG 12 Summary Data Sheets Page 36 of 37 1R23 Spring 2022
SGID Row Col Volts Deg Ind Per CrLen Chn Locn Inch1 Inch2 BegT EndT PDia PType Cal L
Idx Util1 Util2 C2 12 99 184 0.28 86 PCT 11 P2 VS3
-1.04 TEH TEC 0.61 CBAY2 218 C
275 0
12 34 185 NDF P3 VS3
-0.64 VS3 TEH 0.61 NYAX2 61 H
71 0
12 34 185 2.55 178 DNT P1 VS3
-0.64 TEH TEC 0.61 CBAY2 216 C
357 0
12 48 185 0.59 129 PCT 16 P2 09C
-1.15 TEH TEC 0.61 CBAY2 216 C
364 0
12 56 185 0.28 93 PCT 10 P2 VS3 0.83 TEH TEC 0.61 CBAY2 220 C
47 0
12 94 185 0.25 95 PCT 10 P2 VS2
-0.72 TEH TEC 0.61 CBAY2 218 C
270 0
12 98 185 0.25 99 PCT 10 P2 VS2 0.72 TEH TEC 0.61 CBAY2 218 C
272 0
12 98 185 0.34 109 PCT 13 P2 VS4
-0.67 TEH TEC 0.61 CBAY2 218 C
272 0
12 17 186 0.29 57 PCT 10 P2 VS3
-0.89 TEH TEC 0.61 CBAY2 216 C
336 0
12 19 186 0.27 154 PCT 10 P2 VS3
-0.94 TEH TEC 0.61 CBAY2 216 C
337 0
12 23 186 0.41 129 PCT 13 P2 VS3
-0.92 TEH TEC 0.61 CBAY2 216 C
339 0
12 25 186 0.47 122 PCT 14 P2 VS3
-0.85 TEH TEC 0.61 CBAY2 216 C
340 0
12 59 186 0.23 53 PCT 10 P2 BW1
-0.68 TEH TEC 0.61 CBAY2 218 C
33 0
12 87 186 0.34 61 PCT 11 P2 VS2 0.84 TEH TEC 0.61 CBAY2 220 C
257 0
12 93 186 0.33 99 PCT 13 P2 BW1 0.99 TEH TEC 0.61 CBAY2 218 C
267 0
12 93 186 0.27 55 PCT 11 P2 VS3
-0.91 TEH TEC 0.61 CBAY2 218 C
267 0
12 38 187 0.33 36 PCT 12 P2 VS3
-0.89 TEH TEC 0.61 CBAY2 214 C
344 0
12 52 187 0.22 28 PCT 9
P2 BW1
-0.73 TEH TEC 0.61 CBAY2 214 C
351 0
12 54 187 0.41 82 PCT 15 P2 BW1
-1.26 TEH TEC 0.61 CBAY2 218 C
41 0
12 58 187 0.34 131 PCT 13 P2 BW1
-0.71 TEH TEC 0.61 CBAY2 218 C
39 0
12 90 187 0.32 123 PCT 12 P2 BW1
-0.72 TEH TEC 0.61 CBAY2 218 C
263 0
12 92 187 NDF P25 10H 0.86 10H TEH 0.61 NYAX2 61 H
72 0
12 92 187 3.57 183 DNT P1 10H 0.86 TEH TEC 0.61 CBAY2 218 C
264 0
12 92 187 0.48 135 PCT 16 P2 VS3 0.71 TEH TEC 0.61 CBAY2 218 C
264 0
12 45 188 0.33 41 PCT 11 P2 BW1
-0.87 TEH TEC 0.61 CBAY2 220 C
65 0
12 61 190 0.17 45 PCT 7
P2 VS2
-0.81 TEH TEC 0.61 CBAY2 218 C
67 0
12 63 190 0.29 95 PCT 11 P2 BW1 1.02 TEH TEC 0.61 CBAY2 218 C
68 0
12 28 191 0.26 31 PCT 11 P2 BW1 1.03 TEH TEC 0.61 CBAY2 218 C
87 0
12 45 192 0.37 51 PCT 12 P2 BW1
-0.9 TEH TEC 0.61 CBAY2 220 C
120 0
12 40 193 0.46 98 PCT 14 P2 BW1
-0.84 TEH TEC 0.61 CBAY2 220 C
143 0
12 48 195 0.31 126 PCT 12 P2 BW2
-0.8 TEH TEC 0.61 CBAY2 218 C
131 0
12 52 195 0.29 144 PCT 11 P2 BW1
-0.88 TEH TEC 0.61 CBAY2 218 C
129 0
12 56 195 0.44 135 PCT 15 P2 BW2
-1.58 TEH TEC 0.61 CBAY2 218 C
127 0
12 14 199 0.4 123 PCT 13 P2 04C 0.81 TEH TEC 0.61 CBAY2 218 C
197 0
12 21 202 0.38 140 PCT 11 P2 04C 0.73 TEH TEC 0.61 CBAY2 218 C
204 0
12 6
203 0.45 127 PCT 14 P2 04C 0.73 TEH TEC 0.61 CBAY2 202 C
121 0
12 8
203 0.18 151 NQI P1 TSC 0.58 TEH TEC 0.61 CBAY2 202 C
120 0
12 8
203 NDF P45 TSC 0.58 01C TEC 0.61 NYAX2 264 C
77 0
12 14 203 0.44 128 PCT 14 P2 04C 0.81 TEH TEC 0.61 CBAY2 218 C
212 0
SG 12 Summary Data Sheets Page 37 of 37 1R23 Spring 2022
APPENDIX D PLI & PLP DATA SHEETS
SG - 11 SI PLP Calls With Current Cycle Data and Previous Inspection Data Palo Verde 1 U1R23 PVNGS1 20220401 04/26/2022 08:36:48
+-----------+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+----+
l INSPDATE ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL L IDX UTIL1 UTIL2 C2l
+-----------+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+----+
l 43 64 NDD TEH TEC.610 CBAY2 22 C 52 0l l 43 64 12.24 140 PLP 87 TSH.23 08H TEH.610 NYAX2 65 H 46 SR 0l l 2019/04/01 43 64 NDD TEH TEC.610 SBAY2 6 C 70 0l l l l 42 65 NDD TEH TEC.610 CBAY2 24 C 83 0l l 42 65 6.43 137 PLP 167 TSH.43 08H TEH.610 NYAX2 65 H 43 SR 0l l 2019/04/01 42 65 NDD TEH TEC.610 SBAY2 6 C 58 0l l l l 44 65 NDD TEH TEC.610 CBAY2 24 C 82 0l l 44 65 5.52 108 PLP 183 TSH.20 08H TEH.610 NYAX2 65 H 42 SR 0l l 2019/04/01 44 65 NDD TEH TEC.610 SBAY2 6 C 59 0l l l l 164 75 1.23 103 PCT 27 P2 BW2 -.84 TEC TEH.610 CBAY2 29 H 128 0l l 164 75 15.47 82 INR 7 09C 34.20 TEC TEH.610 CBAY2 29 H 128 0l l 164 75 2.71 121 WAR 30.21 P29 BW2 -.84 VS3 TEC.610 NYAX2 64 C 6 F 0l l 164 75 1.94 109 PLP 140 09C 34.20 VS3 TEC.610 NYAX2 64 C 6 HR 0l l 2019/04/01 164 75.93 98 PCT 24 P2 BW2 -.86 TEC TEH.610 SBAY2 29 H 94 0l l 2019/04/01 164 75 INF 8 09C 33.99 TEC TEH.610 SBAY2 29 H 94 HR 0l l 2019/04/01 164 75 2.24 112 WAR.25 P14 BW2 -1.11 VS3 TEC.610 NYAX2 46 C 26 F 0l l 2019/04/01 164 75 4.28 99 PLP.00 40 09C 34.20 VS3 TEC.610 NYAX2 46 C 26 0l l l l 32 79 4.81 108 PLP 8 TSH.50 TEC TEH.610 CBAY2 11 H 147 HR 4l l 32 79.32 84 PCT 13 P2 VS3 -.67 TEC TEH.610 CBAY2 11 H 147 4l l 32 79 9.75 139 PLP 135 TSH.22 01H TEH.610 NYAX2 65 H 18 HR 4l l 32 79 PAC 01H TEH.610 NYAX2 69 H 18 4l l 2019/04/01 32 79 4.10 111 PLP 8 TSH.51 TEC TEH.610 SBAY2 9 H 145 HR 4l l 2019/04/01 32 79 20.60 92 PLP 172 TSH.38 01H TEH.610 NYAX2 55 H 30 4l l l l 33 80 9.50 267 PLP 8 TSH.69 TEC TEH.610 CBAY2 11 H 149 HR 3l l 33 80 2.42 125 PLP 11 TSH.66 01H TEH.610 NYAX2 65 H 12 HR 3l l 33 80 PAC 01H TEH.610 NYAX2 69 H 19 3l l 2019/04/01 33 80 8.16 271 PLP 8 TSH.94 TEC TEH.610 SBAY2 9 H 144 HR 3l l 2019/04/01 33 80.49 156 PLP 111 TSH.85 01H TEH.610 NYAX2 55 H 29 3l l l l 3 192 13.88 118 PLP 124 03H 33.31 08H TEH.610 NYAX2 61 H 30 HR 0l l 3 192 PAC 08H TEH.610 NYAX2 69 H 21 0l l 3 192 1.38 108 PLP 8 03H 33.61 TEH TEC.610 CBAY2 268 C 29 HR 0l l 2019/04/01 3 192 12.53 105 PLP 168 03H 33.31 08H TEH.610 NYAX2 67 H 5 HR 0l l 2019/04/01 3 192 1.67 95 PLP 8 03H 33.35 TEH TEC.610 SBAY2 252 C 30 HR 0l
+-----------+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+----+
l INSPDATE ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL L IDX UTIL1 UTIL2 C2l
+-----------+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+----+
Tubes: 7 Records: 33 1 ST Max
SG - 12 SI PLP Calls With Current Cycle Data and Previous Inspection Data Palo Verde 1 U1R23 PVNGS1 20220401 04/27/2022 11:37:39
+-----------+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+----+
l INSPDATE ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL L IDX UTIL1 UTIL2 C2l
+-----------+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+----+
l 58 13.34 76 DSI P6 FDP.58 TEH TEC.610 CBAY2 14 C 54 0l l 58 13 3.24 119 PLP 39 FDP.67 01C TEC.610 NYAX2 264 C 5 HR 0l l 2019/04/01 58 13.18 55 DSI P6 FDP.60 TEH TEC.610 SBAY2 18 C 36 0l l 2019/04/01 58 13 NDF P8 FDP.60 01C TEC.610 NYAX2 262 C 6 0l l l l 105 104 1.06 94 PLP 8 08H 2.71 TEC TEH.610 CBAY2 21 H 190 HR 0l l 105 104 9.62 111 PLP 156 08H 2.64 10H TEH.610 NYAX2 57 H 81 HR 0l l 2019/04/01 105 104 1.36 89 PLP 8 08H 2.79 TEC TEH.610 SBAY2 39 H 29 HR 0l l l l 75 162 10.99 93 PLP 76 TSH.68 01H TEH.610 NYAX2 61 H 23 SR 0l l 75 162 NDD TEH TEC.610 CBAY2 226 C 105 0l l 2019/04/01 75 162 NDD TEH TEC.610 SBAY2 218 C 191 0l l l l 76 163 20.72 110 PLP 152 TSH.86 01H TEH.610 NYAX2 61 H 27 HR 0l l 76 163 2.93 54 PLP 7 TSH.82 TEH TEC.610 CBAY2 226 C 96 HR 0l l 2019/04/01 76 163 7.96 124 PLP 59 TSH.47 01H TEH.610 NYAX2 47 H 49 HR 0l l 2019/04/01 76 163 2.95 57 PLP 7 TSH.78 TEH TEC.610 SBAY2 220 C 191 HR 0l
+-----------+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+----+
l INSPDATE ROW COL VOLTS DEG IND PER CRLEN CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL L IDX UTIL1 UTIL2 C2l
+-----------+----+----+---------+----+----+----+-------+-----+----+---------+---------+----+----+------+------+------+--+-----+---------+---------+----+
Tubes: 4 Records: 14 1 ST Max
APPENDIX E PLUG MAPS
12 Tube Plugged HL & CL 1R23 A
- 53 Stay Rod A
- 184 Existing Plugged Tube SG - 11 Tubes Plugged 1R23 Palo Verde U1R23 PVNGS1 1RSG Westinghouse Electric Company LLC - ST Max 04/27/2022 05:48:33
5 5
10 10 15 15 20 20 25 25 30 30 35 35 40 40 45 45 50 50 55 55 60 60 65 65 70 70 75 75 80 80 85 85 90 90 95 95 100 100 105 105 110 110 115 115 120 120 125 125 130 130 135 135 140 140 145 145 150 150 155 155 160 160 165 165 170 170 175 175 180 180 185 185 190 190 195 195 200 200 5
5 10 10 15 15 20 20 25 25 30 30 35 35 40 40 45 45 50 50 55 55 60 60 65 65 70 70 75 75 80 80 85 85 90 90 95 95 100 100 105 105 110 110 115 115 120 120 125 125 130 130 135 135 140 140 145 145 150 150 155 155 160 160 165 165 170 170
10 Tube Plugged HL & CL 1R23 A
- 53 Stay Rod A
- 183 PLUGGED TUBE SG - 12 Tubes Plugged 1R23 Palo Verde U1R23 PVNGS1 1RSG Westinghouse Electric Company LLC - ST Max 04/27/2022 11:48:30
5 5
10 10 15 15 20 20 25 25 30 30 35 35 40 40 45 45 50 50 55 55 60 60 65 65 70 70 75 75 80 80 85 85 90 90 95 95 100 100 105 105 110 110 115 115 120 120 125 125 130 130 135 135 140 140 145 145 150 150 155 155 160 160 165 165 170 170 175 175 180 180 185 185 190 190 195 195 200 200 5
5 10 10 15 15 20 20 25 25 30 30 35 35 40 40 45 45 50 50 55 55 60 60 65 65 70 70 75 75 80 80 85 85 90 90 95 95 100 100 105 105 110 110 115 115 120 120 125 125 130 130 135 135 140 140 145 145 150 150 155 155 160 160 165 165 170 170
APPENDIX F FORM NIS-1
APS NIS - 1 FORM OWNERS DATA REPORT FOR INSERVICE INSPECTIONS
- 2. PLANT PALO VERDE GENERATING STATION 2a. ADDRESS 5801 SOUTH WINTERSBURG ROAD, TONOPAH, ARIZONA 85354
- 3. UNIT NUMBER 1
- 4. OWNERS CERTIFICATE OF AUTHORIZATION NONE
- 5. COMMERCIAL SERVICE DATE 1-28-86
- 6. COMPONENTS INSPECTED:
COMPONENT OR APPURTENANCE MANUFACTURER OR INSTALLER SERIAL NUMBER STATE OR PROVINCE NATIONAL BOARD NO 1MRCEE01A STEAM GENERATOR 11 Ansaldo 224 NA 173 1MRCEE01B STEAM GENERATOR 12 Ansaldo 225 NA 174
APS NIS - 1 Page 3 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS SG 11 SG 12 Row Col Ind Row Col Ind 30 79 TBP 124 53 TBP 49 92 TBP 44 87 TBP 48 93 TBP 49 88 TBP 49 100 TBP 48 89 TBP 115 102 TBP 51 106 TBP 47 114 TBP 49 110 TBP 46 115 TBP 49 112 TBP 36 123 TBP 47 116 TBP 42 123 TBP 30 125 TBP 164 125 TBP 37 126 TBP 160 127 TBP 163 128 TBP