WESTINGHOUES NON-PROPRIETARY CLASS 3 LTR-RAC-22-50 Page 1 of 5 Supporting Documentation for SNM-1107 Amendment Request
Corporate 17103 Preston Road, Suite 200 Dallas, TX 75248 Ph. 682.503.0030 Fax. 214.853.5720 Compact Waste Disposal Facility Certificate of Disposal RM-3.2.2-4 Records Management RM-3.2.2 Issuance of Certificates of Disposal/Treatment Effective Date 12/01/2016 Revision 3 Facility P.O. Box 1129 Andrews, TX 79714 Ph. 432.525.8500 Fax. 432.203.2359 Certificate of Disposal Date of Certificate: August 31, 2022 Dene Cauley Westinghouse Electric 5801 Bluff Road Hopkins, SC 29061
Reference:
Transfer # 22-0822-01 WCS Profile #:
WP-9751 Manifest(s):
CWF-WEC-9751-01 {ORIGINAL MANIFEST: WP-9751-268}
Received On:
August 30, 2022 This is to certify that the waste shipped to WCS on the above mentioned manifest was disposed of on August 30, 2022 in the WCS Compact Waste Disposal Facility (CWF). Disposal is subject to the WCS Radioactive Material License R04100 along with all other applicable licenses, permits and regulations.
Waste Control Specialists LLC is pleased to have the opportunity to provide you with the quality waste management services that you need. If you have any questions or need further assistance, please feel free to contact me at (432) 525-8726.
Sincerely, WASTE CONTROL SPECIALISTS LLC Tom Hannah Technical Services Project Manager
FORM540 Waste Control Specialists UNIFORM LOW-LEVEL RADIOACTIVE WASTE MANIFEST SHIPPING PAPER
- 1. Emergency Telephone Number 1-800-424-9300 (Include Area Code)
- 5. Shipper - Name and Facility WCS for Westinghouse Electric Co., LLC 5801 Bluff Rd Hopkins, SC 29061 WCS Generator Certification ID W0013 I
S~ ment Number
'Z*t.-nP.??.('\l Shipper ID Number
- 7. Form 540 and 54-0A SCWESTCOL Form 541 and 541A COLLECTOR Form 542 and 542A Additional Information PROCESSOR
- 9. l.onsIgnee. Name and Faci'ity Page 1 ot 0 GENERATOR TYPE Waste Control Specialists (Specify)
FC CWF Phone No (Include Area Code) 9998 West Hwy 176 Contact A~ rewi;, TX 79714-1 Page(s) 1 Page(s)
None Page(s) 1 Page(s)
Eloctrook:
F
- 8. Manifest Number CWF-WEC-9751-01 Contact Keri Gonzalez Phone No (Include Area Code) 432-525-8800 E.W. Caluley Jr Organization t-----------------------l-8-03-4i_4_7_*_39_0_3 ____ --t o/:,nature fl uthorized rns(:}'ee ackr dgjfij~
rec
_ eipt 1---W-es_tl_ng.a..h_o_us_e_E_l_ect_ri_c_c_o ______.,... __________________ -4 6. Carrier-Name and Address EPAI.D. Number
/ I f ~
~~
1
~}- '\cl
- 2. Is this an "Exclusive Use" Shipment?
- 3. Total Number of packages identified on this manifest?
Waste Control Speclall&ts LLC TXD988088464
'-' I V 10. CERTIFICATION 9998 W. State HWY 176 "This is to certify that the herein-named materials are property classified, described, packaged, marked, and labeled and Andrews, TX 79714 Shipp,~ Date are in proper condition for transportation according to the applicable regulations of the Department of Transportation, the YES
~ * *, "',O* '2. '-
Commission, and equivalent state regulations. For materials that are consigned to a land disposal facility or waste i-----------------.,...--------------------11-----------------------t-b'-l"fl,o:-:nc:e~N~o'-;(-;-:lnc:cl"'u""de~Ar=ea-=---'Cod=e::,1) collector, this certifies that the materials are classified per the applicable requirements of 10 CFR Part 61, meet the land
- 4. Does EPA regulated waste requiring a EPA Manifest Number Contact disposal facility's waste acceptance criteria, and are in proper condition for disposal as described in accordance with the manifest accompany this shipment?
Tom Hannah applicable requiref98nts of 10 i;;FR. Parts 20 and 61, or equivalent state regulations. A collector in signing the certification (432)525-8500 is certifying that ~
as )68_9'{,one to the collected waste which would invalidate the waste generato~s certification."
If "Yes." provide Manifest Number YES
- 11. U.S. Department of Transportation Description (Including UN ID number, proper shipping name, hazard class, and any additional information)
Radioactive material, DSHS exempted package, 7, Transported Under DSHS Modification letter Dated 7/18/2012 (WP-9751)
FUR 1,;uNSIGNEE USE ONLY FORM 540 (06-2021)
Signature
- Authorized catrier acknowledging waste receipt
~,,,?
- 12. DOT Labels 13* i~~~;port
- 14. Physical and Chemical Form NA NA Solid Uranium Oxide
- 19.
Record Waste Description Inadequate Contamination or Leakage Detected Unexpected Exposure Rates Detected Labels, Markings, etc. Inadequate Container Integrity Inadequate Other No Violations Detected on this Shipment Date U-234 Au th£il.,t:;~ A~-
- If!.# M *,. J.1!,
D1-3d.. a
- 15. Individual Radionuclides 1&
ximum Pac~
e Activity MBq I mCi U-235 U-236 U-238 2.1747E+05 ~
776E+03)
- 17. Total Weight or Volume (Use appropriate units) 14600 LBS; 132 FT3
- 18. Identification Number of Package 22-003682/
WP-9751-268
FORM 541 Waste Control Specialists
- 1. Manifest Totals
- 2. Manifest Number No. of Pkgs/
Net Waste Net Waste Disposal Volume Weight Containers (m')
(kg)
U-233 UNIFORM LOW-LEVEL RADIOACTIVE m3 3.57 kg 6622.45 WASTE MANIFEST 1
NP 113 126.00 lb 14600.00 CONTAINER AND WASTE DESCRIPTION Activity All Nuclides Tritium C-14 Additional Nuclear Regulatory Commission (NRC) Requirements for Control, Transfer and 2.1747E+05 NP NP MBq Disposal of Radioactive Waste 5.8776E+03 NP NP mCi Disposal Container Descliption
- 6. Container
- 7. Volume
- 8. Waste
- 9. Waste
- 10. Surface
- 11. Surface Contamination Physical Description
- 5. Container
- 13. Approximate Description Identification (See Note 1 &
(m3)
Number/Generator ID Note 1A)
(ft3)
Number(s) 22--003682/
19 WP-9751-268/SCWESTC Lift Liner 3.74 OL Bag 132.00 Shipment Totals 3.74 132.00 Note 1: Container Description Codes. For containers/
waste requiring disposal in approved structural over*
packs the numerical code must be followed by "-OP."
- 1. Wooden Box or Crate
- 9. Demineralizer
- 2. Metal Box 1 O. Gas Cylinder
- 3. Plastic Drum or Pail
- 11. Bulk, Unpackaged Waste
- 4. Metal Drum or Pail
- 12. Unpackaged Components
- 5. Metal Tank or Liner
- 13. High lnteglity Container
- 6. Concrete Tank or Liner 19. Other. Describe in Item 6,
- 7. Polyelhlene Tank or Liner or additional page
- 8. Fiberglass Tank or Liner FORM 541 (06-2021) and Weight Radiation
- 12. Waste Waste Container Level (MBq/100 cm2)
- 14. Sort>ent Weight Descriptor Volume{s) in Solidification.
(kg)
(mSv/hr)
( dpm/100 cm2)
Container Stabilization, Media (kg)
Tb)
(mrem/hr)
(See Notes 2 & 2A)
(m3)
(See Note 3)
Alpha Beta-Gamma Tb)
(ft3) 33 100 6622.45 6622.45
<1.0000E--07 <3.6740E--06
<0.0000 3.57 14600.00 14600.00
<1.0000E--05 <2.2000E+02
<2400.0000 126.00 6622AS 6622.45 14600.00 14600.00 Note 1A: Bulk Packaging Description Codes. (Choose one code as may be applicable.)
A Gondola B lntermodal C End-Dump D Roll-off E Seavan Note 2: Waste Descriptor Codes. (Choose up to three which predominate by volume.)
- 20. Charcoal
- 21. Incinerator Ash
- 22. Soil
- 23. Gas
- 24. Oil
- 25. Aqueous Liquid
- 26. Filter Media
- 27. Mechanical Filter
- 28. EPA or State Hazardous
- 29. Demolition Rubble
- 38. Evaporator Bottoms/Sludges/
- 30. Cation Ion-exchange Media Concentrates
- 31. Anion Ion-exchange Media
- 39. Compactible Trash
- 32. Mixed Bed Ion-exchange Media 40. Noncompactible Trash
- 33. Contaminated Equipment
- 41. Animal Carcass
- 34. Organic Liquid (except oil)
- 42. Biological Matelial (except
- 35. Glassware or Labware animal carcass)
- 36. Sealed Source/Device
- 43. Activated Matelial
- 37. Paint or Plating
- 59. Other. Describe in item 12, or additional page Special Nuclear Material (grams)
CWF-WEC-9751-01 U-235 Pu Total
- 3. Page 1
of 1
Page(s)
NP NP NP
- 4. Shipper Name WCS for Westinghouse Electric Co.,
Tc-99 1-129 Source (kg)
LLC NP NP (kg) I 1.9033E+03 Shipment ID Number NP NP (lb) I 4.1960E+03 SCWESTCOL Waste Description for Each Waste Type in Container
- 17. Waste
- 15. Chemical Description Weight%
Chemical Fonn/
Chelating Chelating Agent Agent W>
0.1%
Uranium Oxide/NP Note 2A: Specific Waste Descriptions (Choose all applicable codes.)
G Dewatered H Solid I Corn buslible J Non-<:ambustible K Air Filtration Filters L Asbestos NA
- 16. Radiological Description Class AS-Class A Stable Individual Radionuclides and Activity AU-Class A (MBq) and Container Total; or Container Total Activity and Radionuclide Percent Unstable B--Class B Radionuclides pCi/gm MBq mCi C-Class C U-234
[8.4776E-01 kg) 7.84729E+05 1.9228E+05 5.1968E+03 AU U-235
[3.9920E+00 kg] 1.29000E+03 3.1609E+o2 8.5429E+00 U-236
[4.2388E-01 kg) 4.07087E+03 9.9748E+D2 2.6959E+01 U-238
[1.8980E+D3 kg] 9.74418E+04 2.3876E+D4 6.453DE+D2 Subtotal 2.1747E+D5 5.8776E+D3 Total 2.1747E+D5 5.8776E+D3 Source
[1.9033E+D3 kg) 2.1747E+D5 5.8776E+D3 Source
[1.9033E+03 kg)
Note 3: Solidification and Stabilization Media Codes. (Choose up to three which predominate by volume.) For media meeting disposal site structural stability requirements, the numerical code must be followed by "-$." and the media vendor and brand name must also be identified In Item 14. Code 100=NONE REQUIRED.
Sorptlon
- 60. Speed Ori
- 67. Florw X
- 61. ceIetom
- 68. Solid A Sorb
- 62. Floor Dry/Superfine 69. ChemsJl 30
- 63. High Ori
- 70. Chemsil 50
- 64. 5afe T Sorb
- 71. Chemsil 3000
- 64. 5afe N Ori
- 72. Dicape,1 HP200
- 66. FlortO
- 73. Dicape,1 HP500
- 74. Petroset
- 75. Petroset II
- 76. Aquaset TT. Aquasetll
- 89. Other. Describe in Item 14 or additional page Solldlflcallon
- 90. cement
- 91. Concrete
( encapsulation)
- 92. Bib.men
- 93. Vinyl Chloride
- 94. Vinyl Ester Styrene
- 99. Other. Describe In Item 14, or additional page 100. None Requred
Isotope U-234 U-235 U-236 U-238 UNIFORM LOW-LEVEL RADIOACTIVE WASTE MANIFEST ISOTOPES REPORT For Manifest# CWF-WEC-9751-01 Waste Control Specialists Total Activity
~ (mCi) 1.9228E+05 5.1968E+03 3.1609E+02 8.5429E+OO 9.9748B+02 2.6959B+Ol 2.3876E+04 6.4530B+02