14 13 SYSTEM DATA c::v NORMAL UPSET OF BY REMARKS GPM PSIG GPM PSIG A
1 52 98 --
45 JAH 2
53 93 ---
45 JAH 3
70 95 45 JAH 4
50 104 ---
45 JAH 5
50 100 ---
45 JAH 6
45 JAH 7
65 83 ---
45 JAH 8
128 77 --
45 JAH 9
53 76 ---
45 JAH 10 29 89 -
45 JAH 11 45 JAH 12 45 JAH 13 14 101 ---
45 JAH B
C D
E F
G H
J 6
ATM 107 5
K 5
123 54 136 DJL 4
- F PSIG
'F DURATION HYDRO SY CKD NORMAL UPSET DESIGN DATA 6"
12 11 ROp-49 IPX-9068A-HR-VU rTl VENT ROp-49
~
26371-VU \ ~
ROp-49 16362-VU NOTE 5ffi Tscy 1"
I I
\
ROp-4 6431A-VU 6"
lfil ESF SWGR !DA ROOM UNIT 'A' COIL *2 H XAH-6-VL 2" J ~------' 2" 2"
COIL *1 ESF SWGR !DA ROOM UNIT 'A' XAH-6-VL 2"
ROp-49
!PX-'l090A-HR-VU XPS-185-VU MNOTE 5 yTsc I
l1/2"MCN 'C' ROp-4
/
6429A-VU l"
8 ROp-49 VENT ~-N----1 3/4" l 3/4" 6"
4" r
3/4"
- l
\ ROp-49 4"
26361-VU 2"
COIL IN ITYPI COIL OUT ITYPI REMARKS l"
<§>NOTE 5 TSC I
21/2" 1"
ROp-11 6401A-VU ROp-49 :7 3/411 NOTE 7
\
ROp-49 IPX-9070C-HR-VU ROp-49 IPX-9.088C-HR-VU ROp-12 6393A-VU NOTE 5/c'-
TSCV I
ROp-11 \
6399A-VU k,,_NOTE 5 VTSC
~
1" VENT
~
r.7 MNOTE 5 yTSC XPS-191A-VU \
BATTERY ROOM AIR ROp-49 fTl 26357-VU",
26 ROp-10 ROp-10 6443A-VU HANDLING UNIT 'A' r3/4".:,--i::-(f....,.---1~ XAH-24A-AH H I w3/4" 1 I 6445A-VU I
2" 1"
~
JPX-9042A-HR-VU
-49 VENT GA-HR-VU 1.7
,n 0NOTE 5 C
~
TSC XPS-190A-VU
~
SPEED SWITCH RM MNOTE 5 VTSC i0
~
1 2" COOLING UNIT l1/2" H
XAH-19A-VL Wlu-11/2.,.."-1::-:::1-<
12,S 3/4" 6430A-VU l"
ROp-4 6428A-VU 2b ROp-49
/
IPX-9110A-HR-VU ROp-49
/
p
!PX-9052A-HR-VU
\
~OTE 8 1"
11/211 1" 1"
\
RKf-16 16376-VU X
N ISl N
3" r.7 6"
6" 4"
4" 2"
7 ROp-49 26352-VU NOTE 5 3/4" VENT TSC
. -]
6" ffiNOTE 5 yTsc I
6 5
~
L -, r 04
<[
a::
w 0
<[
w I
z*
a::
- J 1-w a::
6" 6"
3" L!_j ~
VENT ~
6" ROp-49'-.._
26360-VU 2"
N
\fl 6"
r.7 3"
A-7
-843 vu l1/2" N_
'i'~ :::,
E 6"
G-13
-841 vu RKf-16 X
16367-V/
~
illt~/
~
b
~
,, XPS-l8Jc-vu CHARGING/SI
\fl 3/4 \
PUMP ROOM *2 rTl l1/2" 1
m 3/4"~
~
~
1---r::.:-1-~~~i..,..i...;.;.i XAH-2-VL I
2"
/
I j"
~---~{
ROp-4 1
NOTE 5
'"' ROp-49 2"
638IC-VU C
JPX-9094-HR-VU TSC 3/4" b
152 15IX
~
\t1/2" RKf-16
\6366-VU
\~
3/4" ANOTE 5~
V TSC -N~--,
fTl -
ROp-4 /
6381A-VU L'..J VENT k,,_NOTE 5 VTSC I
ROp-4 I
6453A-VU \ XPS-192-vu,
~,,L---------
ROp-49 IPX-9116-HR-VU l"
IO N
ROp-4 /
6363A-VU 3/4" RKf-16 16368-VU 1"
Ji"I
,/Rop-10 W '1/
6450A-VU _/
XPS-187A-VU l1/2" ~
ROp-4 L.:'.J 6449A-VU k,,_NOTE 5 VTSC I
X il.l "'
N ROp-49 JPX-9064-HR-VU EMERGENCY FW PUMP AREA UNIT 'A' XAH-llA-VL IPX-9104A-HR-VU ROp-49 TPX::-9058A-HR-VU ROp-4 6417A-VU XPS-186A-VU 2"
SW BOOSTER UMP AREA UNIT ' '
XAH-9A-VL 1"
3/4" ROp-49
4 3
2 1
RO 4
I
_MNOTE 5 VTSC r.,
3/4" 6"
ROp-49 r 26355-VU\
~[:
3/4 ffiNOTE 5 YTsc r _,
5 ROp-4 6372A-VU ROp-49 IPX-9062A-HR-VU
<[
a::
w
<[
w I
_J (L
(L 11/2"
- J (f) 11/2" 1--MI--(
MNOTE 5 VTSC
/ ROp-10 6452A-VU N
\fl X
§ 4
I" ROp-49 26358-VU/
21/2" I.
1-----4 VENT f,74 3"
r~
VEN/ A rn4 3/4" 2"
l"
-49 1----11..,.__:]
ROp-4 /
6378A-VU l
152 151X 2"
6" 6"
k,,_NOTE 5 VTSC I
1" 17 7124197 RHM 16 11*05*95 SRM N--.. ::,
DRAWING LEGIBILITY CLASS 1 SCE&G CAD ENHANCED REVISED PER CGSS-97-0386 MGR GJM REVISED PER MRF -22114 MGR DJL NOTES:
- 1. ALL EQUIPMENT SAFETY CLASS 2b, UNLESS NOTE OTHERWISE
- 2. ALL SAFETY CLASS PIPING TO BE IN ACCORDANCE WITH LINE SPEC 152N
- 3. ALL NON SAFETY CLASS PIPING TO BE IN ACCORDANCE WITH LINE SPEC 151X
- 4. ALL ALARMS AND INDlCA TING LIGHTS ARE LOCATED ON THE HVAC CONTROL BOARD IXCP-6210-41 IN THE MAIN CONTROL ROOM,EXCEPT WHERE NOTED OTHERWISE
- 5. OPERATOR INITIATE INPUT TO THE TSC COMPUTER
- 6. THE HYDROSTATIC PRESSURE LISTEO ON THIS DRAWING IN THE DESIGN DATA BOX IS PER SECTION XI OF THE ASME CODE.
THE VALUE IS BASED ON DEAD HEAD PRESSURE AT THE PUMP DISCHARGE.
THE VALUE ODES NOT INCLUDE ELE-VATION CORRECTIONS.
- 7. CONNECTION CONTAINS PERMANENT SAMPLE CONNECTION. REFER TO lMS-22-1619 FOR DETAILS.
- 8. ALL PIPING ANO COMPONENTS DOWNSTREAM OF
!PX ROOT VALVES ARE NON SAFETY RELATED.
SEE TYPICAL DEPICTION AT !PX 9110A.
THE ASSOCIATED 307 DRAWING SHALL BE REVISED IN CONJUNCTION WITH REVISION TO THIS 302 IF THE CROSS HATCHED AREA IS AFFECTED.
THIS IS A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVIATION SHALL BE INITIATED OR PERFORMED WITHOUT PRIOR DOCUMENTATION A"ID WRITTEN APPROVAL FSAR Figure 9.4-23 SOUTH CAROLINA ELECTRIC ~ GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION PIPING SYSTEM FLOW DIAGRAM CHILLED WATER - TO COOLING COILS
A" 6
DESIGN ENGINEERING 5CEtG 15 0}31-95 SRM REVISED PER MRF-22594 &
MGR CHR A SC.ol-iA COW'ANr V. C. SUMMER NUCLEAR STATION JENKINSVUE. S. C.
MADE CHECKED LE APP:=?0V4L SRM MRF-22114 MGR DJL
- 2.
RHM REVISED PER ECR-71196 MGR LF CRR RHM DJC 19 812V08 JTS CADD ENHANCED PER ECR-50239 MGR DDJ c,,
t/0 SC/11.E D-302-842 19 LE 18 01124105 NO DATE SY REVISION CKD. BY APPROVAf.
DRAIHNG NUMBER SHT. NUMBER REV A
B C
D E
F G
H J
K RN 08-019 October 2008