2 to Updated Final Safety Analysis Report, Figure 9.4-23, Rev. 19, Piping System Flow Diagram Chilled Water - to Cooling Coils a
ML22194A375
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A375 (1)


Text

14 13 12 11 lfil 8 7 6 5 4 3 2 1 SYSTEM DATA c::v NORMAL GPM PSIG GPM UPSET PSIG OF BY REMARKS 6" 6" 6" A

1 52 98 -- --- 45 JAH A

2 53 93 ---

45 JAH ESF SWGR !DA ROOM 3 70 95 45 JAH 4 50 104 --- --- 45 JAH ROp-49 UNIT 'A' COIL *2 ROp-49 ROp-49

--- -- IPX-9068A-HR-VU H XAH-6-VL !PX-'l090A-HR-VU 5 50 100 45 JAH 26352-VU NOTE 5 6 - -- 45 JAH J ~------' XPS-185-VU ffiNOTE 5

--- --- rTl VENT NOTE 5 f f i 3/4" VENT TSC yTsc

~

7 65 83 45 JAH 2" 2" 8 128 77 -- --- 45 JAH 6" ROp-49 Tscy MNOTE 5 6" -]

~

~ r 9 76 --- -- 45 JAH COIL *1 yTsc r

53 26371-VU \

10 29 89 - --- 45 JAH I ESF SWGR !DA I 11 -- --- JAH I 2" ROOM UNIT 'A' 2" 04 45 I l1/2"MCN 'C' ROp-49 12 --- --- 45 JAH XAH-6-VL 26355-VU\ "

13 14 101 --- -- 45 JAH L -,

ROp-49 1"

\ ROp-4 ROp-4 /

l"

~[: 3/4 6431A-VU 6429A-VU RKf-16 >

illt~/

16362-VU X B 16367-V/ ~ B

~

ffiNOTE 5 VENT ~-N----1 YTsc ROp-49 3/4" l 3/4" A-7

~ ,, XPS-l 8Jc-vu b

CHARGING/SI rn RO 4

\fl 3/4 \ PUMP ROOM *2

~ 6"

-843 vu rTl l1/2" 1---r::.:-1-~~~i..,..i...;.;.i 1 m 3/4"~ ~ XAH-2-VL ~

r _,

5 I I j" 2" ~---~{

6" /

ROp-4 . 1 NOTE 5 '"' ROp-49 2" I ROp-4 <[

638IC-VU - - C JPX-9094-HR-VU _MNOTE 5 6372A-VU TSC 3/4" VTSC a::

b ROp-12 ROp-49 w l" 152 15IX JPX-9064-HR-VU 6393A-VU <[

w C ~ I C

4" \t1/2" >-

_J 4" (L X (L 6" RKf-16 ROp-49  ::J il.l 11/2" (f)

\6366-VU "'N r., IPX-9062A-HR-VU

\~ 3/4"

<[ ANOTE 5~ 3/4" 11/2" 1--MI--(

\ ROp-49 IPX-9070C-HR-VU V TSC -N~--,

a:: fTl "'

ROp-49 w 0

IPX-9.088C-HR-VU <[

w ROp-4 /

I 6381A-VU D z* k,,_NOTE 5 D a::

I.

J VTSC ROp-49 1- I ROp-4 26358-VU/

w 6453A-VU \ XPS-192-vu, a:: I

~,,L--------- ,,, 21/2" 6" ROp-49 IPX-9116-HR-VU 3/4" 1-----4 f,74 VENT 3" 3" 4

l" ROp-4 / I" r

6363A-VU E E

~

L!_j L'..J

l <§>NOTE 5 NOTE 5/c'-

VENT ~ VENT rn4 6"

3/4"

\ ROp-49 I

TSC TSCV I

3" 6"

26360-VU ROp-49'-.._ VEN/

r~

A 4"

26361-VU r.7

"'"'IO MNOTE 5 4" N 21/2" VTSC RKf-16 EMERGENCY FW 3/4" 16368-VU PUMP AREA UNIT 'A' 2" 2" 2" ROp-11 ROp-11 \ 1" 1"

6401A-VU 3/411 6399A-VU Ji"I XAH-llA-VL 1" ,/Rop-10 W '1/ / ROp-10 l" 6450A-VU _/ 6452A-VU F XPS-187A-VU IPX-9104A-HR-VU 1----11..,.__:] F ROp-49 TPX::-9058A-HR-VU ROp-4 /

NOTE 7 N -49 6378A-VU N \fl

\fl 152 151X l1/2" L.:'.J

~ ROp-4 6449A-VU X

§ l NOTES:

1. ALL EQUIPMENT SAFETY CLASS 2b, UNLESS NOTE OTHERWISE
2. ALL SAFETY CLASS PIPING TO BE IN ACCORDANCE WITH LINE SPEC 152N
3. ALL NON SAFETY CLASS PIPING TO BE IN ACCORDANCE WITH LINE SPEC 151X 6" 4. ALL ALARMS AND INDlCATING LIGHTS G ARE LOCATED ON THE HVAC CONTROL G BOARD IXCP-6210-41 IN THE MAIN 6" CONTROL ROOM,EXCEPT WHERE NOTED OTHERWISE
5. OPERATOR INITIATE INPUT TO THE TSC COMPUTER k,,_NOTE 5 k,,_NOTE 5
6. THE HYDROSTATIC PRESSURE LISTEO ON THIS DRAWING IN THE DESIGN DATA BOX VTSC VTSC IS PER SECTION XI OF THE ASME CODE.

I I THE VALUE IS BASED ON DEAD HEAD r.7 PRESSURE AT THE PUMP DISCHARGE.

ROp-4 XPS-186A-VU 2" 6417A-VU THE VALUE ODES NOT INCLUDE ELE-

7 ROp-49 2" SW BOOSTER VATION CORRECTIONS.

UMP AREA UNIT ' ' 2" 7. CONNECTION CONTAINS PERMANENT SAMPLE 3" CONNECTION. REFER TO lMS-22-1619 FOR H XAH-9A-VL DETAILS.

H

~

l1/2" VENT 1" 3/4" 1" 8. ALL PIPING ANO COMPONENTS DOWNSTREAM OF k,,_NOTE 5 ' ROp-49 ROp-49 fTl r.7 MNOTE 5 N_ !PX-9!08A-HR-VU !PX ROOT VALVES ARE NON SAFETY RELATED.

VTSC 26357-VU",  :::, SEE TYPICAL DEPICTION AT !PX 9110A.

'i'~ >

yTSC RO 26 "' ' E 2"

ROp-10 6443A-VU XPS-191A-VU \

BATTERY ROOM AIR 1 I ROp-10 6445A-VU 6"

H HANDLING UNIT 'A' I 2" r3/4".:,--i::-(f....,.---1~ XAH-24A-AH I w3/4" THE ASSOCIATED 307 DRAWING SHALL 1" BE REVISED IN CONJUNCTION WITH 1"

~ JPX-9042A-HR-VU REVISION TO THIS 302 IF THE CROSS HATCHED AREA IS AFFECTED.

-49 J J VENT 1.7

- GA-HR-VU X THIS IS A NUCLEAR SAFETY RELATED

,n 0NOTE 5 C

MNOTE 5 "'N DOCUMENT. NO DEVIATION SHALL BE INITIATED OR PERFORMED WITHOUT PRIOR DOCUMENTATION A"ID WRITTEN APPROVAL

~

TSC XPS-190A-VU VTSC

"'ISl G-13

~  : SPEED SWITCH RM \ RKf-16 "'N -841 N-FSAR Figure 9.4-23 2" COOLING UNIT 16376-VU ' " >

- vu <!

HXAH-19A-VL Wlu-1/2.,.."-1::-:::1-<

1 1 11/2 1" 11 SOUTH CAROLINA ELECTRIC ~ GAS COMPANY l1/2" " i0 DRAWING LEGIBILITY 2,S

~

1 CLASS 1 VIRGIL C. SUMMER NUCLEAR STATION l" ROp-4 1" RN 08-019 6428A-VU 2b ROp-49 / 3/4" 6430A-VU October 2008 SCE&G CAD ENHANCED PIPING SYSTEM FLOW DIAGRAM IPX-9110A-HR-VU CHILLED WATER - TO COOLING COILS ROp-49 / A" 6 ATM 107 5 p !PX-9052A-HR-VU 17 7124197 RHM REVISED PER CGSS-97-0386 MGR GJM K 5 123 54 136 DJL COIL IN ITYPI 16 11*05*95 SRM REVISED PER MRF -22114 MGR DJL 6 5CEtG DESIGN ENGINEERING K V. C. SUMMER NUCLEAR STATION JENKINSVUE. S. C.

4 123 45 136 DJL COIL OUT ITYPI \ ~OTE 8 15 0}31-95 SRM REVISED PER MRF-22594 & MGR CHR A SC.ol-iA COW'ANr MADE CHECKED LE APP:=?0V4L PSIG *F PSIG 'F DURATION SRM MRF-22114 MGR DJL 2.

PD NORMAL UPSET HYDRO SY CKD REMARKS 19 812V08 RHM REVISED PER ECR- 71196 MGR LF CRR RHM ' DJC c,,

18 01124105 JTS CADD ENHANCED PER ECR-50239 MGR DDJ DESIGN DATA LE t/0 SC/11.E D-302-842 19 NO DATE SY REVISION CKD. BY APPROVAf. DRAIHNG NUMBER SHT. NUMBER REV