ML22194A357

From kanterella
Jump to navigation Jump to search
2 to Updated Final Safety Analysis Report, Figure 10.4-11, System Flow Diagram Feedwater (Non-Nuclear)
ML22194A357
Person / Time
Site: Summer 
(NPF-012)
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A357 (1)


Text

{{#Wiki_filter:A B C D E F G H J K 14 SYSTEM DATA FLOW PSIG ° F REMARKS 6.429xrn* ~" 1215 335 100% LOAD 2 6.429XI06%, 1190 376 100% LOAD 3 6.429X10° 1)',, 1164 441 1001/. LOAD 126 GPM 205 115 SEAL INJECTION 5 42 GPM ATMOS 135 SEAL LEAKOFF 6 114 GPM 115 350 HOT BLEED-OFF 13 12 TABLE I TT 3488B TT 3489A FT TT 4 FT 3493B TT 3490A FT 494A TT 4 FT 3494B ROb-1 IPS-3481-HR-FW \ ~--tw:'.l-~---13" RC-3 3/4" I XFL-5000-FW ~~1 INJECTION FILTER 16101-FW t::,. ~ SCE&G 1" 1'" ROb-4 / \ 1/ \ 1/ 11620-FW -~R~C~-~3-~ y y ITV-3467-FW SCE&G / 11629-FW ROb-1 / IPS-3481-LR-FW 3/4" 3/4" SCE&G / 11613-FW 2" 3" SCE&G 16071-Fy 11/2" '-, ROb-4 11607-FW DRAIN 1" \ SCE&G \ 1607J-FW 11 SCE&G 1610J-FW SCE&G 1629E-FW SCE&G VENT 11615-FW "' TY 3467 10 9 VENT ROb-9 ~ ROb-9 ~ 8 7 6 5 ~~ CD ~ u ' :-----0 J-5 ~----7 F.W. 1 s--------------7 ,n B-3 1 C12

--r----r~ :

H cs y XPN 6035 © A @1/E H FB INTER. BLDG. F.W.


4 3311 LINE BREAK

~ 4 PLACES ROb-9 lAX-l\-HR2-FW ROb-9 f IAX-11-HRl-FW ~ FT 3310 ROb-9 IFT-3310-LR2-FW 3/4" \ ROb-9 IFT-3310-HR2-FW \ ROb-9 ROb-9 IFT-3310-HRI-FW 30" ROd-1 ~ ROd-1 ---'./ ~ ~ / 24" 24" 24" 901X / ,<}--{:J--------l~----G--::-1--D-------,----------olilf---------------D----t:, 4 J-3 30 ** 3/4'" IFT-3310-LRI-FW /IFE-I 3-FW -083 f---------'---'=~----'--<111---------'=----------_J 20" 3/4" ROb-9 / 1624A-FW VENT 30" 20" ROb-9 / 1625B-FW 3/4" 1-----tof----l*--l>VENT F W ~ SEE TABLE 1 ROb-9 IPX-3282-HRl-FW ROb-9 IPX-3282-HR2-Fwj 3 ~ 1625A-FW 1/2" TE 3283 ,' ____ 0 PX / 3/4" SET PRESS. 1750 PSIG 11/2" N~:,. N' ,u. Den 0: ~ 6 '------D<f----j 3" 2" SCE&G ~1616-FW 3382 3 XFH-12A-FW HEATER 11 1A "-._EcR\'0367 1641A-FW Lb----tof-----tof-----:-*VENT 3/4" l"x3/4" 9 ROb-9 24" 1672A-FW 1673A-FW l1/2"x 1" 16" ROb-9 TI 3305 1/2" IPX-3302-HRl-FW ROb-9 IPX-3302-HR2-Fo/ PX 3302 XFH-12B-FW 3 3/4" HEATER 1118 3 24"\ ROb-9 1624B-FW SET PRESS. 1750 PSIG TE 3303 o/ ~ D -I 11/2" l1/2"x l" 7 1641B-FW L" VENT ..,L 1672B-FW 16738-FW 3 2 1 SCE&G 1612E-FW F.W. PUMP XPP-22C-FW f-1,c-, lXi VENT NOTE: X 3" DRAIN 2" TI 3485D SCE&G 1629J-FW PI J484J DRAIN 2" MINIMUM HYDRO TEST TEMPERATURES ARE 120° F FOR THE 30" PIPING AND 70° F FOR THE REMAINING PIPING. HYDRO TEST PRESSURE FOR f TO f SET BY FW HEATER HYDRO TEST LIMITS PER. ANSI B3l.1 HYDRO TEST PRESSURE FOR f IS SET BY ASME III, BY VIRTUE OF CONNECTION TO ASMEIII CODE CLASSED PORTION OF THE SYSTEM. DRAIN 7 121 347 140 347 < 1% 180 HNG NORMAL CON. ESTABLISHES DESIGN 6 10 135 10 135 < 1% 15 HNG NORMAL CON. ESTABLISHES DESIGN 5 376 115 400 100 < 1% 565 HNG NORMAL COND.ESTABLISHES DESIGN 4 1300 449 1720 449 < 1% 2150 HNG UPSET CON. ESTABLISHES DESIGN 3 1300 449 1720 449 < 1% 2600 HNG UPSET CON.ESTABLISHES DESIGN 2 1300 392 1720 392 < 1% 2600 HNG UPSET CON. ESTABLISHES DESIGN 1300 34 7 1720 347 < 1% 2600 HNG UPSET CON. ESTABLISHES DESIGN [ID PSIG ° F 1 NORMAL PSIG °F 1/. TIME PSIG UPSET HYDRO DESIGN DATA BY CKD REMARKS

  • SEE NOTE I SCE&G 1607L-FW ITV-3468-FW 1610L-FW SCE&G 1610K-FW RC-3 ITV-3457-FW SCE&G 1607E-FW R b-4 11609-FW DRAIN

\ SCE&G \ 1607F-FW SCE&G 1612C-FW PI 3484D SCE&G 1610A-FW RC-3 ITV-3447-FW ROb-4 11611-FW/ DRAIN 1" FI 3486A \ SCE&G\ / 1629C-FW I 11/2" 1/2" s E 0A L F.W. PUMP XPP-22B-FW / I629A-FW SCE&G VENT 11617-FW" © ~ 7B-FW ~-_J 1607A-FW


~I"

~660-FW TY 3447 1" 2" SCE&G \ 11619-FW 3" 151X 2" 5 MRF-21512 1694C-FW MRF-21512 1695C-FW MRF-21512 I694B-FW \ 3" \___:;____j 5 21/2" \ MRF-21512 1695B-FW 2" 4" 151X ROb-2 ~ VENT PX 3276 -~R~O~b~-~9~_~/ IPX3276-HR2-FW ROb-9 IPX3276-HR1-FW 2 XFH-llA-FW DRAIN NOTE 2 HEATER 112A R b-11 1622A-FW 2" \ ROb-11 1623A-FW 2 TE 3277 SET PRESS. 1750 PSIG 3/4" ~ 1" ~ECR70367 1642A-FW LD----1..af---l---c-vENT 3/4" l"x3/4"\ \ ~ ROb-9 24" 1670A-FW 1671A-FW 24" ROb-9 IPX3270-HRI-FW ROb-9 /IPX3270-HR2-FW PX 3270 16" TEE, FUTURE ROb-36 30" PX 3296 __ R~~b~-~9 __ ~/ IPX3296-HR2-FW ROb-9 IPX32%-HR1-FW X - (Sl a-24" 2 1/2" 00 N D ~::::: I 24" SET PRESS. 1750 PSIG ~ 1" 2 XFH-11B-FW HEATER "'2B PX 3290 =R~b~-~9~=-='/ IPX3290-HR2-FW ROb-9 IPX3290-HR1-FW 3/4" ~ECR70367 1642B-FW LD----1..af---l---::-c--f> VENT 3/4" l":3/4"\ \4 ~ ROb-9 1670B-FW 16718-FW 2" /Rb-11 1622B-FW 24" ROb-11 1623B-FW DRAIN NOTE 2 G 1612A-FW F.W. PUMP SCE&G 11618-FW 11/2" i-1c-,,---l)(] VENT ROb-1 ILS-3482-HR-FW 2" ROb-3 ILC-3483-HR-FW ~1/2" ROb-20 / 1682A-FW ffi- ~ ROb-20 1682B-FW \ XPP-22A-FW VENT 8-FW V V ~y L -fic'\ 34868 J \ 3448 - - - - - - ~ SCE&G . SCE&G 1610C-FW 16100-FW NOTES: I. HYDROSTATIC TEST PRESSURES LISTED ARE BASED ON THE ORIGINAL SYSTEM HYDRO PRESSURES USED AND MAY NOT REFLECT CURRENT REQUIRED HYDRO PRESSURES. SEE CALCULATION RECORD ND. DC05210-028 FDR CURRENT SYSTEM DESIGN PRESSURES.

2. HOSE CONNECTION AVAILABLE TD SATISFY OPERATING LICENSE CONDITION 2.C.C34J.

5' 10' 15' 20' DRAIN 1/2" ril I1/2" LC 3483 ILC-3483-LD-FW 1" 16" 20" 20" 4" ~,, / >---CI_J_--'---1.--f:-:l-'-'-1 1/2e..'---1' 3/y. 30" 30" 30" 901X ROb-35 /'<:J----CfL-!-""----------------'------""'--------f-------------'=----'-O----{)I L!.J 3/4" I ROb-1 ~\ ILS-3482-LR-FW . MRF-21512 1695A-FW 12" ~~ FC ILC-3483-LR-FW 3" ROo-12\ 1661-FW 3" 4"x3" 1612JBA-FW 4" ROa-4 / 1662-FW 6"x 4" ECR50638 ILV-3483-FW 6" \ 6"x 3" ROb-8 1663-FW 6" 3/4" ORAi~ 11614-FW 20" I ECR50638 XPS0231-FW CONDENSER 'A' XCN-1-CW 2" Ylof-----llof------, kb-11 1621A-FW DRAIN ROb-11 1621B-FW 20" ROb-35 / 1608B-FW DRAWING LEGIBILITY CLASS 1 SCE&G CAD ENHANCED 24 05/20/08 RHM REVISED PER ECR 50692A MGR RAT 23 10/JD/03 JMR REVISED PER ECR-70367 RHM DDJ 22 06/16/03 JTS ENHANCED PER ECR-50239 MGR DDJ ESSENTIAL FSAR FIGURE 10.4-11 SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION PIPING SYSTEM FLOW DIAGRAM FEEDWATER (NON-NUCLEAR) Q DESIGN ENGINEERING SCE!.G A SCMA C0loF'AIW V. C. SUMMER NUCLEAR STATION JENKINSVILLE, S. C. MADE CHECKED LE APPROVAL.. _2_1 +-09_/1_2/_0_1,__R_H_M-+-__ R_E_V_IS_E_D_P~E~R~M_R_F_-=2=2=5=5=3---+_M~G~R-+--'-J~M~W-----<1.

2.

26 09/30/2D19 CMS REVISED PER ECR-72561 chk DAB RHM MGR

3.

WHM 25 11/10/09 DDJ REVISED PER ECR-50638 RHM AME 11=111-~~~~~~~~~-t-'-~T~L~E~~-~os~,~~, D-302-082 26 NO. DATE BY REVISION CK. BY APPROVAf. DRAWING NUMBER SHT. NUMBER REV A B C D E F G H J K}}