2 to Updated Final Safety Analysis Report, Figure 9.2-1, Drawing D-302-221, Sheet 1, Rev. 32, Service Water Cooling
ML22194A327
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A327 (1)


Text

14 13 12 II 18 q 8 7 6 5 4 J 2 1 r-**-**-**-*--**  ;*. - .. - .. -*.-*.I SCREEN 0 0 SERVICE WATER 1 SERVICE 1 SERVICE PUMP HOUSE TROUBLE PSIG F BY WATER WATER INTAKE TUNNEL POND POND

.... * ""en I L I L

.. ... ccs

""CCI ri';\

A I 15CFM

.tll

  • 7 "5 PJS

¥., PJS

  • - _J I

, s

_____ 1_.

1.fx\

1----u I~

C0~


_J-----L-.I. ./y\

I

, c 1----u I~

_J I


L-.

A 1.-lz\

1----~

I~

A I I I I II I

SCREEN~---- ~ 1 SCREEN r----- 1 SCREEN r-----

1 CDNTRDL, .r.:;\.

1

CONTROL ~ __

I J!'. 1

CONTROL~--~

I I

I

fps\ :

r--~

I

~ ~ ::i"n,2 I

3ll7B-SW PLACES>

- L.!.J TRENCH  :@:

I PS 4433 I

\!!,&

~ ::lc\_ <2

~9~:~w-!:

PLACES>

L.!.J TRENCH  : @.:

I PS 4413 I

~ ~(2 G ~9~:~w PLACES>

-!: L.!.J TRENCH I.. ______ , ~

(f)I .,I ______ (f)I, ~ RGE-3 .,I ______(fJI, ~

21/2" - - - - - _I 21L** 2" 1--+--........

_____..;;,";,;,,.-....iL,,.o,,.;;.,-+,IIXJi-(1


1 XRS-2C-SW TRAVELING B r SCREEN C B 21/2"X2" 21/2"X2"'

21/2"X2" 21/2"'X2"'

ROh-5 ROh-5

/ ROh-1 w IPl-4428-HR-SW

- w ROh-J 3/4"'

CAPPED 0--I CAPPED ti CAPPED f 3/4" CONN. CONN.

CONN.

C C Slfl'ET Q.MS t£RIFICAIIOIS CJIIGIIMlm BY I C.C. 8/21/7'1 IIEYIEIIED BT I P. RAINEY 8/23/74 EF DRAIN VENT PTR-23Jq PTR-23Jq

"' "' 3187C-SW 3186C-SW " ' 1/2" 1/2" 1/2"<TYP.l -*I I

~

RNg-ll /

4" CODLING COIL 3ll3C-SW D 3ll3B-SW !1/2" EJ-3B

'l--1 MPP-3qB-sw D

PTR-2306 xt:E-2SEI-Sw 3"x21/2"' K 1/2' "

~ -

  • PTR-23Jq 3187D-SW 1/2"<TYP.l- ~VENT 1/2"' PTR-2J]q 3187A-SW PTR-2306 4" PTR-2307 Xi:E-26A-5W i---1 /3185-Sw E

......,,.._,- 1/2"<TYP.> u.,i...r-1/2"<TYP.>

1/2' "PTR-23Jq 1/2' -...._ JIB7B-5W PTR-23Jq

....-,.....DVENT q '--D!(J--(4 4 22 PT ~ I E

/4\ @

= 3186B-SW ~

I 1 START SEE SEE DRAIN VENT 3" ]I: '---- --*-- STANDBY ]I:

Ill NOTE 8 NOTE 8 Ill a:' 1 PUMP 24" a:'

J: - J:

BETZ 4" 24" ' '

.CN a: "'

~02 ~---<2{ oQ

.c a: ..,

..- MONITOR IN ...a.

' ...a.

!: 3 "1 Ill

" ...!1

PANEL TO SW 4" L.O.

/

PTR-2J0q 3182B-SW 3"

3" ROh-1 3"

LI. POND ><

cc - ...

F

l:M I"

NOTE q !55X in R~J6

/310 -SW 3"


~*F SAFEGUARD "A" MRF-22144 3Jq3A-SW ~ ..____-<6r-l---------1 3" 14 PLS.> G LOADING SEQUENCE I. SERVICE WATER PUMP MRF-22144 -

XPS-2llA-SW - _.,.. XPS-168A-SW 2. SCREEN NORMAL CONTROLS ISOLATED AND EQUIPMENT ROh-3 EJ-3B CONTINUOUSLY RUNS MPP-J9A-SW XPS-168B-SW

¢.

SAFEGUARD *B-UPPER 14 PLS~ LOADING SEQUENCE 4"' R~-12 I. SERVICE WATER PUMP 3116A-SW \ R 2, SCREEN NORMAL CONTROLS Ii 3/4" 3158A-SW

- MOTOR BEARING h RN -12

,,----r1 PTR-2307/ 3/4"'

\PTR-2504 JlBIA-SW H '\----r1 M 'I I

ISOLATED AND EQUIPMENT CONTINUOUSLY RUNS

'-------------'I I" 3/4"X1/2" l1/2"Xl"

---"""""l)(Jo~H t<<JT LOWER 151X 11/2"-151X 3ll -SW 3184A-SW DR~IN

~~-------~

I I

--~-0 Ii ROh-3 MRF-22144 XPS-2llB-SW EJ-3B iD I I

<fjsF- --0rsc MPP-398-Sw 3" 24" UPPER 30"'X24" 30"X24" 30"X24" I" 3:

H I"' MOTOR I" H

'f' m cc PTR-2503 3158B-SW BEARING re 2u 2" 2" 2" 2** 2" / IFl-4586-LR-SW NOTE

~!1/2'~XI" I" -

~

a.

151X lfilX!~

7

!I! LOWER ><

3/4" 11/2"-151X XPS-120A-SW MRF-22144 \ PTR-2503 3"X2" / IFl-4586-HR-SW 31q3c-sw 30" MRF-22144 XPS-211C-SW i T 3" ~--,

3" 151X 3" 151X

--i{r - -1~H

~

3.. NOTES, 151N 155X ROh-3 3157C-Sw /

EJ-38 MPP-J9C-SW D

6 3r?/ !gw

/ cd

.........r:it:- .J n1 lij" 1

--,;-:;a 1J

}

~

b ~ \!.:,

ad r,:;r-

~

lij" b \ 3 r?/i!gw I

2 *.

ALL COMPONENTS & PIPING TO BE SAFETY CLASS 2b.

ESSE:NIIAL I1/2" l}-~-T....,o...:-~-1)<1....lo-lH I" 152 2"Xlij" 2"Xlij" ALL PIPING TO BE LINE SPEC 152N.

UNLESS NOTED OTHERWISE. THIS IS A J UPPER

~

31718-SW XPS-121B-SW XPS-121A-SW R f- 4 NUCLEAR SAFETY RELATED J 3171 A_SW 3. TEMPERATURE CORRESPONDING TO PERTINENT DOCUMENT. NO DEVIATION SHALL BE INITIATED OR P[RrORMEO WITHOUT PRIOR 3"X2" HEAT EXCHANGER OUTLET. DOCl.lilENTATION Nil WRITTEN N'PROYAL

~ 4. ALL ~ STATUS LIGHTS INDICATE BOTH OPEN &

..__~a 2*;\., 2" 8

)--~

3173A-SW CLOSED POSJTONS UNLESS OTHERWISE NOTED.

5. ITEMS DESIGNATED WITH <fl ARE FURNISHED FSAR Figure 9.2-1 t1/2 ... Xl" 3/4" ROo-12 G-14 BY EQUIPMENT SUPPLIER.

151X w 3"

/ ~174-!lW S<lJIH CNQ.11111 ELECIRIC I !',AS COfWfl

-201 7. HYDRO NOT REOUIRED AS PER CODE CASE N-240, 11/2"-151X I

HYDROSTATIC TEST TEMP. 60" MOTOR BEARING COOLING i ,151X l 156~

cw

8. INTERLOCKS WITH STANDBY PUMP ARE NON-OPERATIONAL. SYSTEM UTILIZES ONLY TWO PUMPS WITH THE THIRD CONSIDERED AS AN INSTALLED SPARE. I.E. NO AUTOSTART CAPABILITIES EXIST FOR DRAWING LEGIBILITY CLASS I SCE&G CAD EtflANCED PIPtlC

¥1111ilL C. !Ulf:R IUl.EIR SIAII~

SERVICE WATER COOLtlC SYSTEM FLOW DIAGRAM K

..... . ...... .,...,.,. II PJS ICJIE 7 ICIIE 7 I

D A STANDBY PUMP DUE TO ADMINISTRATIVE PROCEDURES*

q_ I " TP304 TUBING 0.065 WALL.

32 7/J0/8 31 811116 JMR JMR REVISED PER ECR-72395 REVISED PER ECR-510038 AME RHM PTJ AL DESIGN ENCINEERINC V. C. SUl,ICR tt.JCL[AR STATION ..E:MCNSVI..LE. S. C.

K 30 WWb RHM REVISED PER ECR-510038 MGR PT J 111 <II ICIIE 3 MADE 0£CKED L[ APPROVAL I HI 10. SW CHECMICAL INJECTION DETAILS ARE 29 UJll/6 MAB REVISED PER ECR-50863 GGS MGC 1.

SHOWN ON DRAWINGS D-302-221 SHEET 2 PSIG F PSIG

.,., MGR AME SRM MGR RLJ

~

MA. NT* 28 6119/20~ TGB REVISED PER ECR-50840 BT DD AND D-302-222 SHEETS I AND 3.

IIRII IISD OIIA 27 NO.

V6109 OAT[

JNC REVISED PER ECR-71215 BY REVISION PAH MGC LE CKO. BY AF'PROVAI.

. " D-302-221 i,tl!lllllei IU&A 1 32 Sttl. tu&:R AE ¥