2 to Updated Final Safety Analysis Report, Figure 8.3-1, Sheet 1, Elec. One Line and Relay Diagram Engineered Safety Features Vital AC Sys
ML22194A294
Person / Time
Site: Summer 
Issue date: 06/27/2022
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22194A236 List: ... further results
References
22-179
Download: ML22194A294 (1)


Text

A B

C D

E F

G H

J K

17 121lYAC INSTR. l'I\IN OIST. PNL. lFA APNlFA-EM, CB-M ROO POSITION INJ. PNL. !FCI APNIFCl-EM, !8-0 25 16 4B0Y ~TOR CONTROi. CENTER XMC!DA2X-ES UNIT T 16IJL

) 101lAF 711AT 1m~

25KVA 480-120V 10 VITAL SYSTEM TRANSF.

ESF, !FA XTF!FA-EM 2/C-350MCM 400A BUS 11 12

) 100AF 15AT 13

) 100AF I5AT 15 14

) 100AF 15AT 2/C-10

---1 2/C-10 2/C-10 FU28 I 30A 1

_<;;:>J 2/C*lll IA-ASSOC.I

  • IA* ASSOCJ
  • IA-ASSOC.I BACK-UP FEED TO XPN7005-XI BACK-UP FEED TO XPN7006-XI BACK-UP FEED TO XPN6001*BP BACK-UP FEED TO BOP INSTR. CAB, 'A' XPN6004*BP TO APNlFB-EM OWG. E-206-062 SH.2

~*

18-ASSOC.I 2/C-4/0

) 225AF M ~225AF SEE NOTE 9 J 120YAC INSTR.

PAIEL *1 APN590l* EV, CB*M 225A BUS 13 +

17 +

02 T) ll!IIAF 04 ) 101lAF 05 ) 100AF 40AT 40AT 20AT 15 02

)

14 16

) 100AF 20AT 2/C-10 RAD. MON. SYS.

INSTR. Pl!..

XCP6200-RM VIA XPN5253-EM 225A BUS

) 101lAF 15AT 04

) 100AF 15AT

  • 19 31 05 13 CHANNEL A 225AF 23 225AF 22

) 150AT

) I50AT

)IIIHAF SEE NOTE 20 SEE NOTE 20 51lAT 2/C-1/0

)

) IBHAF 15AT 06 ffi1

~I

~I i!: L' X

2/C-2 I

FU! I 50A 1

~I 2/C-1/0 2/C-2 IA-ASSOC.I

) ll!llAF 25AT FlA.L LENGTH CR[)1 C()lT, PWR. CAB.

XCA0001A*CR 07

) 10BAF 15AT 08 10

) 1110AF 15AT 12 2/C*B

) 101lAF 15AT 10

) 100AF 20AT 11 UNIT T 14 ABR )

I 10 9

480V MOTOR CONTROL CENTER XMC!DA2Y-ES UNIT T UNIT T GAB~ ) llll!AF GAB~ ) ll!IIAF JllAT 30AT 3/C-6 3/C-6 NORWAL SOURCE AllERNAlE SOURCE

~-------'-48=0VccAce~=.,iacc,H,=60i'-"Z'---+-------~-~120V 7 AC,1PH,60HZ 10KVA STAL II.JS U.P.S.

~15901-EV (1115-37-HS)

BACKUP SOURCE TO 125\0C DPNIHA-ED @--

Di<<:. E-206- 062 SH. J 150A

. - L:=J_cn, PR£-OlARCE

-l

)40A UPS

~

~CTIFIER L~60A

) ~2~A

'._".'.)

IH o-fsov

'160A STATICO S'MTOlT ltr---i II 12

):f

) 100AF 20AT 13

) 1011AF 15AT T

o-2oov C<'

55-65HZ (iv 0-150A ~ )--

14

' 250A NON-AUTO UPS 001PUT

.,___~_2-1/c-2/o 27 16

)100AF I5AT 100A

~

)::f DA TO APN5907-EV THIS DWG. f 21c-2

)-:f.

21 17

) IIJ0AF I5AT 8

CHANNEL 18 1q 2ll

)lll!AF I5AT

)

)IBBAF 20AT 7

6 5

4 APN5901-EV 2 - 20AT 2

  • 25AT 1-30AT 1
  • 225AT 3

7 SPACES-100AF-2 POLE 2

SPARE BREAKERS IN PANELS APN5902-EV 2

  • 20AT 1
  • 30AT 2
  • 225AT 13 SPACES-100AF-2 POLE APN!FA-EM I - 30AT 1 - 70AT 1-100AT 1-125AT 2
  • 150AT l

6 SPACES-I0BAF-2 POLE 4 SPACES*225AF*2 POLE APN5907*EV APNlFCHM 10 - 15AT 2

  • 15AT 2 - 20AT 2 - 20AT l -30AT l - 30AT 11 SPACES 1
  • 35AT

--- -- --------~ORM;SOUR;


t-AllERNA=lE~SOU=R7.CE~*-~~-~-- --_-_-_-_-_-_-_-_-_- _-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-__ -,----z_-_5_0_A_T ___ ___ I D--:

480VAC,3PH,60iZ I

120VAC,1PH,60HZ

~--

- -----~ ~----------+,--~

10<VA STAL BUS UP.S.

~T5902-EV (IMS-37-145)

BACKUP SOORCE TO 125\llC 150A DPN1HA-ED c 1-~+---,-~:::i*f"fr

~

. E-206-Cli2 SH. 3 Pll[-QlARGE 12BVAC INSTR.

)

PANEL "2 APN5902*EV,CB*M 29 Bl 82 04 05 El

  • J

) !BB/If 20AT

) 100AF 15AT

) 101lAF 15AT

) I00AF 15AT

'~ l

  • 110A 1

'yTy*.

11;!1 RECTIFER Q160A

--~

~' 0-;.2~0*

...~)

  • , 25DA

' NON-AUTO I UPS OOlPUT 2-1/C-2/O

)225AF 25 07 08

) IIIBAF 15AT

) 100AF 15AT

)

21 225A BUS 09 10 12 13 15

) ll!IIAF 15AT

) 101!AF 15AT

)100AF 20AT

) IBBAF 15AT 0

0 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C*te 2/C-10 2/C-10 2/C-10 2/C-8 2/C-10 2/C-10 2/C-10 2/C-10 2/C-I0 2/C-IR 2/C-10 2/C-10 2/C-I0 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 3/C-4 3/C-4

~r -----

- --1

~I FU!

FU2 I

~ I 60A 60A I

i!:L' 0

_ _ O_J 3/C-4 3/C-4 ROD POSIT!ON ROD POSITION IND. PNL. 1

!Nil. PNL. 2 XPN7060-CR XPN7061-CR 2/C*te ROD PDS. IND.

PLC XPN605B &

MCB DISPLAYS IZM01200 & !ZM01201

____ __ ______________ _ _____ ___ _________ ____ ____ J 120VAC INSTR.

PANEL ' 7 APM5907-EV, CB-M l4 T)l0BAF 15AT 11T)l00AF 20AT 225A BUS 2sT

) 100AF 20AT TO APN5'101-EV THIS DWG.

g

!NCORE THCPLE.

ANALOG ISL TR.

CAB.A XCP6231A*IC 2/C-2 32 )100AF 15AT N!S CHANNEL I CONT, PWR.

XCP7071-Nl 2/C-12 2/C-10 2/C-10 2/C-10 2/C-12

~r:: ---1

!;1 I

~I 3A I

~L' __ _ I 2/C-12 ISOLATION RELAY PANEL XPN54B4-RH BOP INSTR. CAB.

TRAIN 'A' XPN6001-BP ltr: ---,

181 FU2A I NI 30A 1 IL' <2.1 2/C-I0

  • Ill-ASSOC.I PROCESS RACK CONTROL GROUP 1 XPN7005-XI BOP INSTR.

CAB. 'A' XPN6004*BP

l'r
---I

~I FU! I ii'; I 15A I

ifl.'

X

_q__l 2/C-12 ISOLATION RELAY PANEL XPN5477*RH l/4":;; 1'-0" 0'

NIS CONT. BD.

SOI.ID STATE CHANNEL I INSTR. BUS I PROTECTION INSTR. PWR.

XPN7110-MC SYS. CHAN. I XCP7071*NI TRAIN 'A' XPN7010-SG 5'

10' 15' SOLID STATE PROTECTION SYS. CHAN. I TRAJN 'B' XPN7020-SG 20' ltr ffil

~I i~

2/C-I0 IA*ASSOC.l TRANSMITTER PROCESS RACK POWER SUPPLY PROTECTION CAB. CHANNEL A SET I APN5912A-EV XPN701ill-XI FU2B 1 20A 1

~I 2/C-10 IA-ASSOC.I lE AUX.

REACTOR REACTOR HVAC NSS ESF LOADING RELAY RACK PROTECTION VESSEL LEVEL CONT. BO.

AUX.RELAY SEllUENCE XPN5303-ES UNDERFREll.

CAB. RIGHT XCP6210-AH RACK 1 CCXiT. PNL.

& UNDERVOLT.

XPN7248*RC IXPN7I70-AHI XPN703HiG TRAIN 1A1 RELAY PNL. I XPN6il20*5G XPN6B!HS ffir

.i,I ;,

><L' 2/C-10 Ill-ASSOC.I AUX.

REACTOR SAFEGUARDS CORE CDDLIIJG CAB. TRAIN 'A' MONITOR XPN7034-SG UNIT A XPN7218-RC w

NI AMP.

i SORCE &

!NT MD.RANGE CHANNEL I XPN7303-Nl NI AMP.

SOURCE &

!NTMD.RANGE CHANNEL !I XPN731l4*Nl CONT. BO.

INSTR. BUS 2 CHANNEL D XPN7113-MC N!S CHilNNEL !I CONT. PWR.

XCP7072-NI NIS CHANNEL !I INSTR. PWR.

XCP7072*Nl ffir ---1 ffl I FU! I

~I 20A I

ii: L'

~I 2/C-10

  • lO*ASSOCJ TRANSMITTER POWER SUPPLY CAB.CHANNEL D APN5912C-EV SOLID STATE PROTECTION SYS. CHAN. II TRAIN 'A' XPN7010-SG SOLID STATE PROTECTION SYS. TEST PNL.

TRAIN 'A' XPN70U-SG SOLID STATE PROTECTION SYS. CHAN. II TRAIN 'B' XPN7020-SG PROCESS RACK PROTECTION SET II XPN7002-Xl ltr ---1 ffil FU2A 1

~I 30A 1

ii:L' ~I X

2/ C-10 ID-ASSOC.I PROCESS RACK CONTROL GROUP 2 XPN7006*Xl REACTOR PROTECTION UNDERFREO.

& UNOERVOLT.

RELAY PNL. ll XPN6012*ES L---------- ---------------------- --- - ------ -------- ------ - ------ ------ ----------- - ---------------- ---- --- -------------

r<<JTES,

!. t, - BREAKERS WITH AUXILIARY CONTACTS FDR INDICATl()l IN CONTROL ROOM.

2. M
  • MECHANICALLY INTERLOCl<ED BREAKERS, 225AF BREAKERS S!fJWN WITHOUT TRIP SETTINGS ARE WITHOUT TRIP ELEMENTS, 3.INSTRUMENTS SHOWN ARE LOCATED OR MOUNTED ON ASSOCIATED EUIPMENT UNLESS OTHERWISE NOTED.
4. * - INDICATES ITEMS DR AREAS THAT ARE NOT NIUEAR SAFETY RELATED INNSI.
5. ACB BREAKER RATINGS SHOWN ARE COR. RATINGS WITH 61!1JAF.
6. AVAILABLE SHORT CIACUIT CURRENT AT BUS !HA OR !HB IS 20,600A AT I25VDC.
7. MECHANICALLY INTERLOCKED BREAKERS ARE FOR USE AS DISCONNECT ONLY AND WILL NOT BE USED FDR PROTECTION CODROINATIDN
  • B. TIE BREAKERS ARE !NTERLOCKED TO ALLO\I ONLY TIE TWO BREAKERS ASSOCIATED WITH CHANtEL 'A' DR Tl£ TWO BREAKERS ASSOCIATED WITH CHAlff:L 'B' TO CLOSE AT ONE TIME..
9. Tl£ BREAKERS ARE MECHANICALLY INTERLOCKED TO ALLOW ()lL Y ONE BREAKER CLOSED AT A TIME.
10. - INDICATES METERING IN THE ESF POWER SYSTEM WHICH IS 'NNS'. CIRCUITS TO THIS METEROO, FROM TIE NEAREST PROTECTIVE DEVICE, WILL BE RlN AS ASSOCIATED lXA, XB, DR XCI.
11. <==> - ISOLATION DEVICE, CLASS !E TO NON-CLASS !E.
12. 0 - REACTOR BU!LDOO PENETRATION PROTECTION DEVICE.
13. USE BUSSMAN LIMITRON OR GO.Ul-CHASE SHAWMUT FORM 60IJ FUSES FOR CLASS IE ISOLATION FUSES AND PENETRATION PROTECTION FUSES ON ALL PANELS, EXCEPT FOR FEEDS FROM PANELS APN5901, 2, 3, 4, 7, ANO B WHICH REQUIRE GOULD*CHilSE SHAWMUT FORM 101 FUSES.
14. BREAKER TO BE SET AT 'HIGH' TRIP.
15.

DELETED

16.

DELETED

17.

DELETED

18. PANELS REDUIRE HIGH INTERRUPTING TYPE 'FH' BREAKERS,
19. AF, AMP. FRAME AT C AMP. TRIP 20, BREAKER TO BE SET AT 'HIGH' TRIP.

TltS IS A NUCLEAR SAFETY RELATED DRAWING LEGe'-ITY DOCUt.lENT. NO DEVIATION SHP4..L BE CLASS 1 INITIATED OR PERFORMED WITHOUT PRIOR tcs"c"'e*'"'G,....,.CAD=-=-eN""H,..AN_C,..E-jD DOCUMENTATION AND WRITTEN APPROVAL ~ --- --~

41 I 11 11 ***

REVISED PER ECR-50113 JRO 40.....

MAB REVISED PER ECR-50538 HJM GSK

,. 11211*

JMR REVISED PER ECR-50686 MGR RH

,..,,.,.. RHM RE:VtSEO PER CGSS-~8-01J2 MGR JEG 37 "'""'

JMH REVISED PER MRF-218"44 DVW RCB

~- ""

8Y REVISION CICD, IIY,..,,,.,,,._

FSAR Figure 8.3--1 S0JTH CIIRO..INA B..ECTRIC

  • llAS CCN'Hff VIROIL C. st..M£R NJCLEAR STATIOO GILBERT ASSOCIATES, INC.

ELEC. ONE LINE AND RELAY DIAGRAM ENGINEERED SAFETY FEAT~ES VITAL N::, SYS.

Q DESIGN ENGINEERING

,. __ V.C.SI..Mll!lt NlJOLENt 5T,.TIJN JMH DVW RCS E-206-062 1

41 OIWl'INU ~ llffT.--

A B

C D

E F

G H

J K