ML22194A257
Text
17 I
16 I
15 I
14 I
13 I
12 I
11 I
10 I
'! i I
8 I
7 I
6 I
5 I
4 I
3 I
2 I
1 n
A 480V MOTOR CONTROL CENTERS MISCELLANEOUS FUSE PANELS (AC) 120V AND 125V DC DISTRIBUTION PNLS-CKT C BRKRC A
OVER CURRENT PROTECTION DEVICE PENETRATION LOAD OVERCURRENT PROTECTION OEVlCE PENETRATION LOAD OVERCURRENT PROTECTION DEVICE PENETRATION LOAD REMARKS LOCATION APPLICATION CLASi E UIPMENT NO REMARKS LOCATION APPLICATION CLASS EQUIPMENT NO REMARKS LOCATION APPL!CA TION L.,LASS EQUIPMENT NO
RESPONSE
NO.
COND.
SYSTEM
RESPONSE
NO.
CON.
SYSTEM
RESPONSE
NO.
CON.
SYSTEM (OUTBOARD PARENT UNIT NO BACK-
~ ~
TYPE TEST SET POINT TIME XRP SIZE PARENT UNIT NO BACK-
~ ~
TYPE TEST SET POINT XRP SIZE PARENT UNIT NO BACK-
~ ~
TYPE TEST SET POINT XRP SIZE CKT. NO.l PR!
DESCRIPTION OR TAG NC PR!
TIME DESCRIPTION PR!
TIME DESCRIPTION
~
DEVICE NO. OR TAG N(
UP DEVICE NO.
UP DEVICE NO. JR TAG NC UP XVT80'l6B-RC/
MAIN PRESSURE HEATER SQUARE 0 FUSED BUSSMAN RB311l3-PS REACTOR HEAD VENT
~ 76 MICROHMS NOS, 1-B. 21-30 t'IPNi'llA2 BREAKER 2 V
X SOUARE D RB303 XMC1DB2Y 121M X
V FHL36015-225 AMPS N/A 0030
'"4 AWG APN4104 V
X NIA
!!1f0 AWG 45 AMPS
< 40 SEC c1114 AWG PERSONNEL PSK11X A
VALVE TO PRESSURE
- DISCONN, KTU-800 QOB-115 CONAX
!3M 47-58-RC AIRLOCK RELIEF TANK SWITCH XVT809GB-RC/
SQUARE D
< 100 SEC REACTOR HEAD VENT DISCONN.
SQUARED RB202-PS XMC1DB2Y 121M X
X 60 AMPS 0030
- 4 AWG NIA 0022 111/lll AWG APNWA2 BREAKER 4 X
X 45 AMPS
< 40 SEC RB202 PERSONNEL 1FL34021i'J VALVE TO PRESSURE APN4104 SWITCH 1 SPARE tl14 AWG PSKl2X QOB-115 CONAX B
RELIEF TANK AIRLOCK B
XVG88088-SI FUSED BUSSMAN PRESSURE HEATER SQUARE D
< 20" SEC 0030
\2) ;i,4 AWG ACCUMULATOR B DISCONN.
X X
~ 1.0 M!LLIOHM N/A 0022
"'!/li'l AJi.JG GROUP 28, 55,,
APNIDAI OOEAKER 14 X
SQUARE 0 XMC1DB2Y 161M X
X 300 AMPS APN4104 l<TS-R80
)(
45 AMPS
< llilil SEC 0028 "12 AlvG 1201/ CONTROL LDK48XA FHL36100 ISOLATION VALVE SWITCH 2 56-RC GOB-115 XVG8808B-SI FUSED PRESSURE HEATER 161M
)(
X SQUARE D 301ll AMPS
< 200 SEC 0030 (2) t4 AWG ACCUMULATOR B DJSCONN.
BUSSMAN
~ 1.0 MILLIOHM XMC1082Y IFL3411210 APN4104 X
X N/A
@022
'111/0 AWG GROUP 29,57, ISOLATION VALVE SWITCH 3 KTS-R80 58-RC XVG3108C-SW/
SQUARE D FUSED PRESSURE HEATER XMC10B2Y 181M X
X 45 AMPS
< 100 SEC 0018 "4 AWG RB RECIRCULATING DlSCONN.
X X
BUSSMAN
~ 1.0 MILLIOHM NIA 0022
""110 AWG GftOUP 28.5.3, FHL36015 UNIT C APN4104 KTS-R80 ISOLATION VALVE SWITCH 4 54-RC XVG3108C-SW/
FUSED PRESSURE HEATER X
X SQUARE 0 45 AMPS
( lllil SEC 0018
- 4 A~IG RS RECIRCULATING X
X BUSSMAN
~ 1.121 MILLIOHM 0022 atl/0 AWG GROUP 21. 47, APN1FB BREAKER 15 X
X SQUARED 45 AMPS
{ lf,l!!I SEC ii12 AWG 120V CONTROL XMC10B2Y 181M IFL340I5 UNIT C APN4H'l4 DISCONN.
KTS-RB0 N/A FAB-TM15A EEP781X:
ISOLATION VALVE SWITCH 5 48-RC XVG31080-SW/
FUSED PRESSURE HEATER C
SUARE 0
( lllll SEC 0018 RB RECIRCULATING
- OISCONN, X
X BUSSMAN
~ 1.0 MILLIOHM 0022
<11/0 AWG GROUP 1, 2, C
XMC10B2Y 191M X
X 45 AMPS
""4 AWG UNIT C APN41/i'l4 KTS-R60 NIA FHL36015 SWITCH 6 22-RC ISOLATION VALVE XVG3111180-SW/
FUSED PRESSURE HEATER XPN7060-CR/
SQUARED X
X SOUARE D 45 AMPS
( lll!IJ SEC 1/1018 e!l-4 AWG RB RECIRCULATING OISCONN.
X X
BUSSMAN
~ UI MILLIOHM NIA 0022 11110 AWG GROUP 5. 6, APNlFCl BREAKER 2 X
X 120 AMPS cum SEC -
0::-4 AW ROO POSITION 12ElV AC XMC1D82'1' 191M FA-t00/40AT IFL341Zll5 UNIT C AP!\14I04 SWITCH 7 KTS-R80 27-RC IND PANEL 1 ISOLATION VAL VE XVG3109C-SW/
FUSED PRESSURE HEATER XPN706l-CFV SOUARE D 0030 RB RECIRCULATING DISCONN.
BUSSMAN 0022 APN1FC1 BREAKER 4 X
X SQUARE D 120 AMPS
( Ulli SEC
"'-4 AWG ROD POSITION XMC10B2Y 201M X
X 45 AMPS
( lll0 SEC "4 AWG APN4104 X
X
~ 1.0 MILLIOHM NIA
"'1/0 AWG GROUP 3, 4, FA-I00/40AT 0053 120\1 AC FHL36015 wm c S'i'JITCH 8 KTS-RB!?J 25-RC IND PANEL 2 ISOLATION VALVE XYG310':IC-SW/
FUSED PRESSURE HEATER X
X SUARE D 45 AMPS
< llil!I SEC 00:30
.ft4 AWG RB RECIRCULATING DISCONN.
X X
BUSSMAN t 1.0 MILLIOHM 0022
-,,.1/0 AWG GROUP 7, 8, XMC1DB2Y 20IM APN4I04 N/A IFL34015 UNIT C SWITCH q KTS-R80 30-RC ISOLATION VALVE XVG:310"10-SW/
FUSED PRESSURE HEATER X SQUARE D 45 AMPS
< nm SEC 0030 "4 AWG RB RECIRCULATING
- DISCONN, X
BUSSMAN
!_ 1,0 MILLIOHM 0022 GROUP 24, 51, APN500!:
BREAKER 18 X
X GOULD 45 AMPS
< 11l0 SEC
- 12 AWG 120V CONTROL XMC1082Y 2HM X
X N/A 11110 AWG FSK27X D
FHL36015 UNIT C APN4104 SWITCH 10 KTS-R80 52-RC EH1-B015 D
ISOLATION VALVE XVG31090-SW/
MAIN I
SQUARED RB RECIRCULATING FUSED BUSSMAN PRESSURE HEATER I
X X
{ 101! SEC
'"4 AWG X
X
~ 76 MICAOHMS 0021 XNC1DB2Y 211M 45 AMPS 0030 UNIT C APN4105 DISCOl\l'II.
- 1/0 Ar/G NOS, 15-20. 38-46, IFL34015 KTU-800 ISOLATION VALVE SWITCH 67-78-RC I
XVG8811B-SI/
PRESSURE HEATER SUARE D RECIRCULATING FUSED HRJ121XA X
0101B
"'4 AWG BUSSMAN GROUP 17, 18, SQUARE 0 0017 XMG1DB2Y 22CG X
FHL36050 150 AMPS
< 200 SEC SUMP TO RHR PUMP APN4105
- DISCONN, X
X 1.0 MILLIOHM NIA 002]
"'1/0 AWG APN5':101 BREAKER 14 X
X 45 AMPS
< U!lil SEC
- 12 AWG HRJ47XA SWITCH I KTS-R80 42-RC FA-TM15A 120V CONTROL AHW21XA I---
A ISOLATION VALVE XVG88116-SI/
PRESSURE HEATER FUSED 22CG X
X SIJUARE D 150 AMPS
< 2B0 SEC 01fll1B i,4 AWG RECIRCULATING X
X BUSSMAN
~ 1,0 MILLIOHM 0021 GROUP 19, 20, XMC1DB2Y SUMP TD RHR PUMP
- DISCONN, NIA
- J./0 AWG IFL341!!50 APM4105 KTS-R60 45-RC A ISOLATION VALVE SWITCH 2 SGUARE D XVG8095B-RC/
FUSED PRESSURE HEATER XMC10B2Y 23FJ X
X FHL36015-225 AMPS NIA 0030
"'4 AWG REACTOR HEAD VENT DISCDNN.
X X
BUSSMAN
!_ 1.0 MILL!OHM NIA 0021 lol/0 AWG GROUP 38. 87, X
X SQUARED VALVE TO PRESSURE APN411215 KTS-RBi!!
APN5tJ03 BREAKER 12 45 AMPS
< 1(30 SEC il'12 AWG 120V CONTROL AHW11XB
!3M SWITCH 3 68-RC FA~TM15A RELIEF TANK E
XVG80'i5B-RC/
FUSED PRESSURE HEATER E
XMClDBZY X
X SQUARE 0 6121 AMPS
< 11!0 SEC 0030
,.4 AWG REACTOR HEAD VENT DISCONN.
X X
BUSSMAN
~ 1.e, 0021 GROUP 3':I. 69, APN5903 BREAKER 14 X
X SQUARED 45 AMPS
( lt!!il SEC 012 AWG 23FJ MILLIOHM N/A 1,110 AI-IG 12(,lV CONTROL AHW31XB IFL34020 VALVE TO PRESSURE APN4105 KTS-R80 FA-TM15A RELIEF TANI<
SWITCH 4 70-RC FUSED PRESSURE HEATER DISCONN.
X X
BUSSMAN
~ 1.1~ MILLIOHM NIA 0021
~1/0 AWG GROUP 44, 75, APN4105 SWITCH 5 KTS-R80 78-RC FUSED PRESSURE HEATER APN5':115-EV/
i--
OISCONN.
X X
BUSSMAN
~ 1.0 MILLIHM 0021
,;,,1//ll AWG GROUP 41, 71, X
SGUARE D
{ 100 SEC TRANSFORMER 120V AC APN4l.05 NIA APNS'i£16 BREAKER 25 X
l~A-lf'l0/20AT 60 AMPS 0018 1:-4 AWG SWITCH 6 KTS-R80 72-RC POWER SUP[PL Y CABINET 3 FUSED PRESSURE HEATER DISCONN.
X X
BUSSMAN
~ 1,0 MILLIOHM NIA 0021 111/0 AWG GROUP 43, 73, APN41@5 l<TS-R80 SWITCH 7 74-RC FUSED PRESSURE HEATER F
DISCONN.
X X
BUSSMAN
~ 1,0 MILLIOHM N/A 0021
- 1/0 AWG GROUP 15. 16, APN5ti07 BREAKER 3~
X X SOUARE O 45 AMPS
< lllil SEC APN4105 0017
'"'12 AWG 120V CONTROL RHV7A F
SWITCH 8 KTS~R8!Zl 40-RC FAB-TM15A FUSED PRESSURE HEATER DISCONN.
X X
BUSSMAN
~ 1.0 MILLIOHM NIA 0021
.:110 AWG GROUP 46, 77, APN4105 KTS-R80 SWITCH ti 78-RC MAIN PRESSURE HEtlTER FUSED V
X BUSSMAN
) 120 MICROHMS NIA 0020 1/0 AWG NOS. '1-14, 31-37, APN5908 BREAKER 21 X
X SQUARED 45 AMPS APN4106 DISCONN.
A JJS 500 FAB-TM15A
( lfll!il SEC
- 12 AWO 120V CONTROL RHV14B SWITCH 59-66-RC f---
FUSED
~
~
V V
V V
PRESSURE HEATER APN4H2J6 DISCONN.
X X
BUSSMAN
( U'.l MILLIOHM NIA 0020 11-110 AWG GROUP 9, 10, SWITCH l KTS-R80 32-RC FUSED PRESSl.ffiE HEATER APN4106 DISCOHN.
X BUSSMAN
~ 1,121 MlLLIOHM NIA GROUP 11, 12, X
KTS-R80 0020
.:c110 AWG SWITCH 2 35-RC G
G FUSEO PRESSURE HEATER DISCONN.
X X
BUSSMAN
~ 1.0 MILLIOHM NIA 0020 c;-1/0 AWG GROUP 31, 59, APN411216 KTS-R60 SWITCH 3 60~RC
~
FUSED PRESSURE HEATER APN4106 DISCDNN.
X
)(
BUSSMAN
~ 1.0 MILLIOHM NIA 002lll ~1/0 AWG GROUP 36,65, SWITCH 4 KTS-RS0 66-AC FUSED DPN8007C EO f---
PRESSURE HEATER SOUARE D APN4106 DISCONN.
BUSSMAN
~ 1,0 MILLIOHM NIA GROUP 13, 14, DPNlHX-ED BREAKER 14 X
)(
120 AMPS EMERGENCY SWITCH 5 X
X KTS-RB0 IZl0211'l
~1/0 AWG FH-11iJ0/
< l!ffl SEC 011J53
'111/0 AWG LIGHTIMG 1251/ DC 37-RC 40AT PANEL 7 FUSED PRESSURE HEATER OlSCONN.
X X
BUSSMAN
~ 1.!11 MILLIDHM NIA 0020 #1/0 AWG GROUP 33, Sl, APN411l16 SWITCH 6 KTS-R80 62-RC H
FUSED PRESSURE HEATER H
OISCONN.
BUSSMAN tu GROUP 34, 63, SQUARED RB2e2 RB202 PS APN4106 X
X KTS-R80 MILLIOHM NIA 0020 "'l/0 AWG
[JPNI.HX2-ED BREAKER 2121 X
X 45 AMPS
< 40 SEC
""14 AWG PERSONNEL PSE4)(
SWITCH 7 64-RC FAL26015 CONAX AIRLOCK RB303-PS
[JPN1rl)(HU BREAKER 21 X
SQUARE D 45 AMPS
< ffl SEC RB3il3 "14 AWG PERSONNEL PSE3X FAL26015 CONAX AIRLOCK J
V NUCLEAR SAFETY RELATED FSAR Figure BG-4 SOUTH CM!UIIA 8....ECTRIC !ri [;AS COMPANY VIRGIL C, SIJl!MEFI NUCLEil,R STl'\TIDN I(
GILBERT ASSOCIATES INC.
K ELEC. CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTION DEVICES 9
3/21/01 JMR RE'llSED PER MAF-34428 & MflF-2lll'l61 MGR scs
.6 T DESIGN ENGINEER!NG a
OB/25/99 JTS REVISED PER NCN-97-1280 MGR RLJ 7
'I0/24/97 HJM REVISED R MRF-22074 TWO OAP
~
V.C..SI.JljME!I STATIC.. JEUl<!HSV!LLE s.C, T
=
~ "~
6 ID/201114 RHM REVISED PER CGSS 94-1414 MGR GJM I"
DVW I'
RCB s
O!l/07193 JMH REVISED PER MRF-22074 JHR WLJ JMH 4
OS/Wlll3 JMH REVISED PER MRF-21644 DVW RCS
..,,;.,,,_,,T E 224-532 I 4 19
'°* ""' "
REVISION Cl<O. BY A?FROVAL IIRMII~-
SHr.~ R~
i 1/!fl I' -0 fl r f
' I C'
j' 10 15' 10
~