ML22194A217
| ML22194A217 | |
| Person / Time | |
|---|---|
| Site: | Summer (NPF-012) |
| Issue date: | 06/27/2022 |
| From: | Dominion Energy South Carolina |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML22194A236 | List:
|
| References | |
| 22-179 | |
| Download: ML22194A217 (1) | |
Text
A B
C D
E F
G H
J K
14 13 SYSTEM DATA PSIG BY REMARKS 50 150 WTW 50 15 WTW 100 13 WTW S.F. PURIFICATION PUMP 180 GPM !l 200 FT. (TDH)
SC-NNS SAFETY CLASS VERIFICATION ORIGINATED BY REVIEWED 8V SF SF 0, SI EM SUFFIX VALVE I'.. *-
16650 16687 6650 6749 FIRST NO.
LAST NO.
NUMBERING *-
C-5
- NOTE, A. TEMPORARY STR~NER FOR SYSTEM CLEAN UP, TO BE REMOVED AFTER FINAL FLUSH
-715 X
ON ROm12 6676-SF
@3X42D 6674-SF 151R 151R 3"
3" LL 00 (/)
N 00 0
(0
"' (0 ROf44
/
--~
6681-SF ABANDONED IN PLACE ROc32
~
ROf36 6696-SF 3"
N "-
V, E es 0 r--
0' <D 4"
(0 4"
151R 151R 7
NOTE 7 1------ X "' "' ~
2" "2" 10" 12 ROf3 6717-S
~ -El
~~ 1; 3/4~;, ~
(/)
w (0 X
U OO
(/) ~
155 LOCAL\'/
SAMPLE]
RESIN PROBE SCE&G 4 "
16685-
'f LOCW SAMPLE ROf38 6741-SF 155X X
2" 11 FIELD PURCHASED 6746-SF X
"1 "1
ROb-52 6745-SFROf-39
~
n SPENT FUEL COOLING DEMINERALIZER SC-NNS RGb-1 XDM-3-SF 2"
1
\
ROf39 6695-SF 2"
10 155X 2"
2" R0m7
~
4 2"
151R 9
8 7
ROf 35
\_\____ - c~s"'F'"
-- l x:;~~1 cs Rl-9B PORT ABLE RESIN\
/
XPS-112B-CS 1"
FILL TANK
\
/
XTK-47-CS
\ ______ /
J---L-Pufo----
SC-NNS
_ J:1/' 1-8529-CS 1_8544_cs Rl-9B ROf36
/
6735-SF 155X I
7,:
XPS-112A-CS t
A-5 A-8
-t-r-
\IJ
\)
3"
__ 2z" ~iJ--
--'-~cl~~~ I 2"
fr~
...L 1-8530-CS Li-8531-C-;--
RMWS
~
Rl-9C XPS-110-CS
- NOTE, FOR VALVES SHOWN IN PHANTOM SEE E-302-674 SPENT RESIN STORAGE T A1K 2"
E -11 ROf38 c-;,i,N 0 u~z
-737 E-10
-822
\ IPl-7421-HR-SF
"' V, 0 "'
O' <D
<D 155X 3"
VENT 3 >-_;_;:='-----------------------------'-----------,
S.F. PURIFICATION 3"
ROh30 FILTERS ROf38 v,
7423 ro ~
Pl~~
"' r--
0..!...
"' 9,, ROf38
/6710-SF 3/," /
155X 3"
"-v, I
OJ N r--
o,
"' 0:
R0m-6 SC-NNS
_R_O_m_6 ______ 16652-SFRGb-5 ~
~
,....,.E,.,,J.,,-_1F=,.....,-=-6-68~~~3/
IPl-7452-HR-SF
- ~ MPP-328-SF OH '-.,
ROf39 R Gb - 2
'-;6~6"'8"'9,---"SF,,..-
X FL - 6 B -SF
~ -
XPP-328-SF I
R0m6
";""~O u "' z l!J R0/38 IPl-7451-HR-SF \
R0g18 6711-SF SPENT FUEL HEAT EXCHANGER
'-., ROf-39 6675-SF A
7138-WD 3,..i,~
>------<~J--~
i~:-0
'--l, LT I /~B
'--....;7407
- l. 77407 R0m6
-0,p HI
\
67 38-SF
/-
A
_ml-~-
B 1 I
LO 3/,
I 151R 10" v V, N'
~-
ON O' :;;
151R
\
R0g18 6651-SF s
10" 6655-SF
,------SPENT FUEL COOLING PUMP 1800GPM*
100FT. ITDHI
/ {,~~ :\
R0m6
~
IPl-7454-HR-SF R0m6 16650-SF 6
F EJ-1F 3/,"
E-n E-n
/ MPP-32A-SF l-..!.!~'sso0:s~-oocoisl5 --J RM }--~---*-----1 R0m6
\L4 /
RM RM
-... 5 __
7 RGb-5 I
IPl-7441-HR-SF 75 HP XPP-32A-SF 1750RPM ROm6 IPT-7444-HR-SF ROh24 6722-SF 10" 1"X 3/.q" R0m6 3/,"
16655-SF 151R 151R SCE&G 16687-SF
'la" R0m6 16661-SF SC-2b II B II 6
CONCRETEc:;
W~L SKIMMER OUTLET 2"
SECTION THROUGH SKIMMING TROUGH 4"
5
..,...--z..
ST~NLESS STL. PLATE N
~C~-~3 __
,RECYCLE 3"-151R,
,-------lie;;;--"'-'"-, E-302-751 OLDUP
/
5~420 BR TANKS 6708-SF 10" 151R 4
NOTE 11 3
ORZo 155X 151R LJ NOTE 11 ECR 50692 t XVG16730-SF I ~
FIE LO 2Y2J:5x_________T 8-4 21/2" ~
I ~L--6-:~~---J>~...:B::_::3;.___3~".. /
1:.. '
-693 l-'----------H----1 ~
4 17"2./
SI NOTE ECCS SEMI-AUTO SWITCH OVER 1MS-51-32-29 SC-2A REFUELING WATER STORAGE T~K MB-5 XTK-25-RW 2
X 8"
C-1 912-125 PLANT VENT VENT r
VERFLOW 0 4 --11--~4*~--,
151R
"-., ROp35 6704-SF 155X 4j' "-
0 V,
- a. 0 0
r--
n-
<D 3/."
151R
___ill ECR 51003 ~
09750-SF LL
~,.
z "'
0"'
O' "'
4"
-693 SI TO RHR PUMPS 151 155X G-5
-322 20" 14" F-9
-822 3
1/)
- a. 0 0
n- "'
155X LOCAL SAMPLE 155X 4" 155X 4"
3"
(
,R";:._15,1._R
)....,
n-
)
)
(
(
)
)
(
(
)
)
(
(
)
)
(
(
)
)
(
(
)
)
(
(
)
)
(
(
)
n-
)
(
-(
)
'-!2 )
{
-' (
)
)
(
"' (
)
)
(
(
)
)
(
(
)
)
(
(
)
)
(
(
)
)
(
(
/
()
)
)
(
(
)
)
(
(
)
)
(
(
)
)
(
(
<)R'.~()
)ro,)
(
0 "q"
(
)LOOl)
(
Ct:O(
)
l) 00
)
(
w r--,
(
)
)
(
(
( )
3" )
0 6"c l LC
)
(
ROP51 6701-SF 3"
L.C.
I G
L-0 460V 151R 155X 151R FX 9764-SF ECR51007 ND
- NOTE, NO. OF TEMP. ELEMENTS REDUCED FROM 3 TO 2 VALVE CASK LOADING AAEA EL. 427'-0"_
ROf35 L.C. _ill 66~~,SF \--j---,Jl,~@4X420 6680-SF
\
T.C.& E-~~~~
DRAIN ROg19
\
'y{0 6666-SF O"
ILOC~I z O' ow I
a_j
>- O' V, "'
~il 6697-SF l'-'-lf--hl ONLY 3"
NOTE 6 2" 2" 2" 2" 3" 151R BV R0p29 6657-SF EL. 457'-6" NOTE_g_l
~
FUEL TRANSFER 151R 3" TUBE XNF-9-FH ROm14 I\
r-""T""'-r--,
1---=....=--'-'-'-__,,
PEN.
6670-SF I 2"
2" 2" 2" EL. 457'-6"
'---NOTE 9
"-v, v '
N 0
.c N 0
"' <D 1"X 3/,"
"' 0 0
Cl'. :g ROm 6 Pl-7442-HR-S 10" 3/,"
"-v, O')..!i:: <(
' w z >- >-
0' V, 0 xz
-302-822 LDC IF-31 /
ROm6
/
16653-SF 10" 151R 10" 10" (ili)
FUEL TRANSFER CANAL NOTE 3 7129 REFUELING CAVITY F>~
0 (7:~;
~
v
,---- fis"\
4" RCDT
~
0--f +'
151R I
PUMPS~ - --C><,l-----=:.....~~1---.J WO
\
R0m15 6678-SF e l
E i
~~
I Tl
_./
\__... ~
p
-c 11 77 150 84 200 l 11.
105 10 35 150 35 200 l 1x 44 9
35 150 35 200 8
35 140 35 150 (1;,:
7 26 140 26 150 6
60 120 60 150 l 11.
5 35 140 35 150 44 XX lK 4
35 140 150 150 188 XX X 3
22 120 22 120 2
110 140 118 150
( 11/.
148 X XX 1
77 140 84 150 l 11/.
105 x XX
[No) c'Pc°Se°IG='c-F----t-_PS_IG--'--c'-cF=-cce-DU~R_AT_I07N HYDRO HYDR I
NORMAL UPSET PSIG TEMP.
DESIGN DATA WTW LRC WTW LRC WTW LRC U
I ORC
" HYDRO NOT REQ'D PER N-240 CODE CASE lK,c ST ANDING WATER HYDRO
""" HYDRO TEMP.
40' F MIN.ISTAINLESS STEEL!
60° F MIN.(CARBON STEEL!
1/4"=!'-0.,,
0' 5'
10' 15' 4~'
7
+-I L.C.
5 4X42D 151R 6679-SF B
20' 10" 151R
~
SPENT FUEL COOLING PUMP 1800 GPM o ROm6 100FT.<TDH) 16669-SF 151R 151R 10" 3/4" r;i 2"
ROm6 16659-SF E-911-103 LDC. A-10 151R 10"
"'~~
0 0
"' <D r
SPOOL PIECE 6"
6" 6"
6" SC-2b
/Roh-26 6658-SF 10" RGb4
/
-~
16662-SF 10" 6"
6" 6"
I
\ ROm6 IPX-7448-HR-SF
....._____-,;,,R;;,0;',mc"6=-
16660 -SF E.O. AUX BLDG.
L--)-1 E-911-103 LDC. (F-6) 6" 10"-151R 10
6" 6"
6" 6"
~
V>
J m
<D v E V 0
c;-
"' ~
be 151R 10" NOTE 2 3"
3" NOTE 2 K._ 151R(8
~ --- EL. 457'-6" TOT ALI _.
EL. 454'-6" ---*t:::
151R 18 L@3X42D 6669-SF NOTES 1 & 2-2" 2"
2" 2"
EL. 457'-6" SPENT FUEL POOL SC-2b 10" 6"
6" 6"
-/
TOT~)
51 04/2111011 CMS 50 OJ/19116 JMR 49
~107115 KO NOTES:
- 1. ALL PIPING TO & FROM S.F. POOL SHOULD PENETRATE POOL WALLS AT EL. 460'-3" (ilOF PIPE) OUTLETS TO BE ON OPPOSITE WALL FROM SUPPLY LINES.
- 2. LOCATE (2)1/z" ANTI-SYPHON HOLES AT EL. 460'-3" IN EACH 6" SUCTION & DISCHARGE LINE & (1l1/2" HOLE IN 2" SPENT FUEL PURIFICATION PUMP SUCTION LINES PENETRATING THE POOL WALLS.
- 3. BOTTOM OF PIPE TO BE APPROX. 2' FROM BOTTOM OF FUEL TRANSFER CANAL. ALSO PIPING TO PENETRATE CANAL WALL NO MORE THAN 30' ABOVE BOTTOM OF PIPE
- 4. HYDRO TEST PLUMBING-EMERGENCY CORE COOLING SYSTEM SEE DWG.E-302-693 FOR TANK CONN. TO BE LOCATED ABOVE WATER LEVEL.
- 5. SKIMMING TROUGH TO BE ALONG FULL LENGTH OF NORTH WALL OF S.F. POOL. SEE SECTION THROUGH SKIMMING TROUGH.(4-2" TROUGH DRAINS REQ'D.)
- 6. SKIMMING TROUGH TO BE ALONG EAST WALL OF REFUELING CAVITY. SEE SECTION THROUGH SKIMMING TROUGH.(10-2" TROUGH DRAINS REQ'D.l
- 7. SKIMMING TROUGH TO BE ALONG NORTH WALL OF CASK LOADING AREA. SEE SECTION THROUGH SKIMMING TROUGH.
- 8. MUST BE ROUTED THROUGH S.F. DEMINERALIZER.
- 9. PIPING LEADERS TO PENETRATE LINER WALLS AT EL.460'-3" <C OF PIPE) LOCATE A 1/2" ANTI-SYPHON HOLE AT 460'-3" EL. IN EACH LINE PENETRATING THE LINER WALLS.
- 10. SYSTEMS AND COMPONENTS MARKED AS "QR" HAVE BEEN DE -CLASSIFIED TO NNS AS COVERED BY THE QUALITY RELATED PLAN FOR RADWASTE SYSTEMS. SEE CGSZ-371-QA.
- 11. PROVIDED TO SATISFY OPERATING LICENSE CONDITION 2.C.(34).
REVISED PER ECR-72411 REVISED PER ECR-51007 REVISED PER ECR-51007 DRAWING CLASS LEGIBILITY 1 chk MEM RHM NG MGR AF THIS IS A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVIATION SHALL BE INITIATED OR PERFORMED WITHOUT PRIOR DOCUMENTATION AND WRITTEN APPROVAL ESSENTIAL FSAR FIGURE 9.1-3 SOUTH CAROLINA ELECTRIC ~ GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION PIPING SYSTEM FLOW DIAGRAM SPENT FUEL COOLING 6
DESIGN ENGINEERING SCEIG A SC/ltill COIIIPIM' V. C. SUMldER NUCLEAR STATION JENKINSVILLE S. C.
MADE CHECKED LE N'PROVAL 48 IVDI~
GGS REVISED PER ECR-50879 JNC CR
- 1.
- 3.
>---+--------+-----+--------------------------------------------->-------+---------<
47 11/0J/l5 ESB REVISED PER ECR-50879 GGS CR ACI RHM ROB 46 09/~1106 JTS REVISED PER ECR-51007 MGR AF
~.,
c-'-t---------j------j--==~~~=~=~--------c-~-t--::----!MO SCIH LE 0-302-651 51 NO.
DATE BY REVISION CKD. BY AP PROV AL DRAWING NLMBER SHT. NUMBER REV A
B C
D E
F G
H J
K