ML22194A161
| ML22194A161 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 06/27/2022 |
| From: | Dominion Energy South Carolina |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML22194A236 | List:
|
| References | |
| 22-179 | |
| Download: ML22194A161 (1) | |
Text
A B
C D
E F
G H
J K
I 2
3 1-4 13 SYSTEM DATA PSIG SCFM
'F BY REMMKS 238 5110 1211 JGS 1110 5110 1211 JGS 24110 111011 1211 JGS r---,
r---,
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I l
,RH-8b 16301J-NN
,RH-8b 1631311-NN RH-8b RH-Bb
'16302J-NN
'163021-NN
<V-11
<V-11 (i)
I I
___.J L---.J 12 11 1111
- CONNECTION POINT r---
I I
I I
I I
I I
I I
I I
,RH-§b 16301H-NN RH-Bb ALTERNATE CONNECTION POINT AVAILABLE AT THE VALVE TO CONNECT A SINGLE HOSE TO THE VENDOR SUPPLIED HEADER ON THE 16 CYLINDER NITROGEN PACK OR SINGLE CYLINDERS MY BE CONNECTED.
r---,
r---,
r---,
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
RH-8b RH-8b RH-8b RH-8b 16301G-NN 16301F-NN 16301E-NN 16301D-NN
<V-
)
RH-Bb RH-Bb RH-Bb RH-8b
'16302H-NN
'16302G-NN
'16302F-NN
'16302E-NN
'163020-NN
<V-11
<V-11
<V-11
<V-11 IV-II I
I I
___.J I
I I
I I
I I
I I
I I
I I
, RH-Bb 16301C-NN IV-21 RH-Bb
'16302C-NN
<V-11 I
___.J r---
I I
I I
I I
I I
I I
I q
\ RH-Bb 16301B-NN IV-21 RH-Bb
'16302B-NN IV-II I
___.J r---,
I I
I I
I I
I I
I I
I I
\ RH-Bb 16301A-NN IV-21 RH-Bb 16303A-NN ISV-21 RH-Bb
'16302A-NN IV-II RH-Bb /:
163038-NN I
<SV-11
___.J 8
SET PRESS 11 265111 PSIG SET PRESS 11 2650 PSIG MRF-21026 16336-NN
"' z
~z MRF-2UIJ26
/i 16337-NN HIGH PRESSURE NITROGEN SYSTEM (NN)ACCUMULATORS FILL CONN.
RH-Be
/
16324-NN
<V-21 THERMAL RELIEF ITYP 6 PLACES>
RH-Be 16321-NN ISV-21 ECR72141 26349-NN
/
N ex, ECR72404
- M U. M a: "'
~ -
ECR72404 2800 SCF TOTAL USABLE CAPACITY IF INDIVIDUAL BOTTLES ARE USED 4480 SCF TOTAL USABLE CAPACITY IF PACK IS CONNECTED (16 BOTTLES>
16339-NN MRF-2111126 XPS-5029 MRF-21026
,r XPS-5028 RH-Be
/ R-1 RH-Be
/16333-NN
..,_1---...1-----'------.-----e,<1---L-tllc'.l----f"~'cv-11 RH-Be /
/RH-Be 16331-NN IV-121 RH-Be 16328-NN IV-II RH-Be
/
16334-NN
<V-41 RH-Be RH-Be
/
16327-NN ISV-31
---i / 18051-NN IPCV-11 SET 11 150 PSIG RH-Be RUPTURE OISC
<TYP 2 PLACES!
R-2/1-----
~~t---i.._
I I
18050-NNIPCV -21
/RH-Be 16329-NNIV-13>
RH-Be
/
ILl-8081-HR-NN IV-81 (f)
RH-Be/
16317-NN 1---_J IV-91 RH-Be
/ ILl-8081-LR-NN IV-101 XGS-5-NN RH-Be
/16320-NN ISV-51 RH-Be
/
16314A-NN IV-151 z z
([
M RH-Be 16314B-NN IV-161 RH-Bb IPI-8051-HR-NN IV-31 RH-Bb 16304A-NN
<V-51 (NOTE 31 RH-Bb IPI-8061-HR-NN IV-41 RH-Bb f16304B-NN
<V-61
!NOTE 31 z z m
M CONTR 7
GAi 6
5 J
2 TUBE TRAILER DISCHARGING STATION RH-Bb 16305-NN IV-81 RH-8b 16306-NN ICV-11
/RH-Bb 16307-NN IV-7>
FLEXIBLE HOSE
-----------------------------------------~
3/4"-2503X 1"-2503X l"-2503X l"-2503X 1"
ROp-29
/ 6302 NN 3/4"-2503X
~-@.
r C-2 1
- .1 l~B l"-2503X
~
- 1 J:I I
>-----....:.--==::.:..-~
-23~02~-~6'l~2C: ------; ",I - - - - - - - - - - - - - - - - -,
I SI 1-8966A 1
1 1
1 t
ROp-29
/ 6303-NN
,c,,....
L.J.
I c,.J I
I t-,_ __
l-C~:;.. "*"
c,.J PEN., CIV c..~1-8857 6310-NN 1
,. r., V -'~
,-.1., ~
~.
,- - - --i,*_,- - -- - - -i,*,J-320, -.,1- -- -L-~ - --- - --i 1
1-8893 CIV 1-8947 1-8880 I
I '-----
I.I.,
l"-2503X C-l
">------.:....==.:....-t.J!!:-~30~2~-6~9~2>------,"',,j- - - - - - - - - - - - - - - - - -'
OUTSIDE INSIDE SI 1-8966B BLOG BLDG RH-Be r*-------------------------------------------------------------------
16309-NN ISV-91 I
I I
I I
RH-Be RH-Be f16311-NN IV-21111 z z a:
1 RH-Be 16322-NN IV-71
~
I ASV 3 AMBIENT AIR VAPORIZERS U2l L--------------------
XHE-20-NN 1
....L=-----.IIJ' 16313-NN ISV-71 I-O
- N ex, NN I
ISi>
Fl 8073 (f)
RH-Be SET PRESS C! 125 PSIG RH-Be RH-Be
/
16326-NN ISV-41
/
RH-Be /
HI>
\
\
RH-Be
<V-5>
~
.. l..
VACUUM GAGE CONNECTION RH-Be 16325-NN 16323-NN
,.._ ___....:.;la.:V;::-3.a:;I..;.;;.'---'------------'
IV-II
- SEE NOTE 2 3
111 1211 125 121 (1%
2 2311 1211 245 121 (1%
1 2411 1211 26!ifl 121 (1%
24511 P!.L
~
PSIG F
PSIG OF IJlllA.
PIIEU BY Ol(I)
REMARl(S IOIMAI.
IJ'SEI IESIGN DATA I
I CRYOGENIC LIQUID STORAGE
.,f,'
TANK ~
~
SCF
.... I XTK-117-NN
\
RH-Be 16318-NN IV-61 5'
10' 15' 20' RH-Be 16315A-NN (V-171 RH-Be 16315B-NN IV-181 r----
I I
I I
a: a,--
0.. -
RH-Be /
RH-Be
/
RH-Be / -1._
RH-Be 18052-NN 16310-NN 18053-NN u:ill 16312-NN 1
ITCV-11 IV-19>
IPCV-31 IV-211 I
I 1
PRESSURE CONTROL MANIFOLD XGS-11-NN 1
~--------------------------------------------------------------------------*
LOW PRESSURE NITROGEN SYSTEM (NN)
NOTES:
I. ALL VAL VE NUMBERS OTHER THAN THE 6300 NUMBERS ARE BY VENDORS.
- 2. SYSTEM SHALL RECEIVE AN INITIAL SERVICE LEAK TEST PER ANSI 83110 AT DESIGN PRESSURES INDICATED.
- 3. 'A' HEADER SHOWN IN SERVICE WITH 'B' HEADER IN STANDBY.FOR NORMAL OPERATION, EITHER HEADER MAY BE PLACED IN SERVICE WITH THE REMAINING HEADER IN STANDBY.
SET PRESS C! 125 PSIG 28 27 26 25 24 23
~o.
IFI-8073-HR-NN IV-251
/
RH-Be 16308-NN <V-241 CONTR 156X 151X GAi IFl-8073-LR-NN IV-231 ILKOOI 2"
2" 151X DRAWING LEGIBILITY CLASS 1 SCE&G CAO ENHANCED 12/11/18 CMS REVISED PER ECR-72141 CWB AME 12/117/18 CMS REVISED PER ECR-72404 AME RKF 11/17/18 JMR REVISED PER ECR-50931 DC AME IBIIJ'l/18 JMR REVISED PER ECR-72404 AME RF 115/23/17 JMR REVISED PER ECR-72212 RHM AME 12/112/17 JMR REVISED PER ECR-72212 RHM OB LE DATE BY REVISION CKO. BY APPROVAL.
E-6 D-302-742 WPS ESSENTIAL FSAR Figure 5.2-SA SllJTH CMILINA ELECTRIC* GAS ClNWtY VIRGIL C. SINER Mil.EM STAT Ult PIPING SYSTEM FLOW DIAGRAM NSSS CARBON DIOXIDE AND NITROGEN SUPPLY DESIGN ENGINEERING V. C. SUWER t<<JCLEAR STATIOt.l JEtf<IGVI.LE S. C.
OtECl([D LE APPROVAL SRM RHM LEK 0-302-717 28 i:,IAWIICJ~R SHT. ~MIIER REV A
B C
D E
F G
H J
K