ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: __PRAIRIE ISLAND_____________________ Date of Examination: SEPTEMBER 2018 Exam Level: RO Operating Test No.: PI-ILT-NRC-18 _

Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System / JPM Title Type Code* Safety Function

a. MALF OF AUTO MAKEUP DURING BORATION (VC-29SF) A,N,S 1
b. RETURN 13 CHARGING PUMP TO STANDBY (VC-104S) N, S 2
c. RCS / RCP THERMAL BARRIER HX LEAK (RC-24SF) A, D, P, S 4P
d. STOP TDAFWP w/ ACCUMULATOR FAILURE (AF-21SF) A, EN, N, S, L 4S
e. ALTERNATE CFCUs w/ CFCU HI TEMP (ZC-1SF) A, D, EN 5
f. MANUAL START D5 EDG FROM CR (EG-20S) EN, N, S 6
g. PRM / SECURE R11/12 IN CONTROL ROOM (RM-5S) D, P, S 7
h. FIRE ALARM MONTHLY TEST (FP-8S) N, S 8 In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. RCP SEAL ISOLATION AFTER LOSS OF ALL AC (RC-8) D, E, L, R 2
j. LOCAL OPERATION OF 22 TD AFWP (AF-16F-1) A, D, EN, 4S
k. STARTUP PORTABLE BATTERY CHARGER (DC-1) D, E 6
  • All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room (D)irect from bank 9/8/4 (E)mergency or abnormal in-plant 1/1/1 (EN)gineered safety feature 1 / 1 / 1 (control room system)

(L)ow-Power / Shutdown 1/1/1 (N)ew or (M)odified from bank including 1(A) 2/2/1 (P)revious 2 exams 3 / 3 / 2 (randomly selected)

(R)CA 1/1/1 (S)imulator

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: __PRAIRIE ISLAND_____________________ Date of Examination: SEPTEMBER 2018 Exam Level: SRO-I Operating Test No.: PI-ILT-NRC-18 Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System / JPM Title Type Code* Safety Function

a. MALF OF AUTO MAKEUP DURING BORATION (VC-29SF) A,N,S 1
b. RETURN 13 CHARGING PUMP TO STANDBY (VC-104S) N, S 2
c. RCS / RCP THERMAL BARRIER HX LEAK (RC-24SF) A, D, P, S 4P
d. STOP TDAFWP w/ ACCUMULATOR FAILURE (AF-21SF) A, EN, N, S, L 4S
e. ALTERNATE CFCUs w/ CFCU HI TEMP (ZC-1SF) A, D, EN 5
f. MANUAL START D5 EDG FROM CR (EG-20S) EN, N, S 6
g. NONE
h. FIRE ALARM MONTHLY TEST (FP-8S) N, S 8 In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. RCP SEAL ISOLATION AFTER LOSS OF ALL AC (RC-8) D, E, L, R 2
j. LOCAL OPERATION OF 22 TD AFWP (AF-16F-1) A, D, EN, 4S
k. STARTUP PORTABLE BATTERY CHARGER (DC-1) D, E 6
  • All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room (D)irect from bank 9/8/4 (E)mergency or abnormal in-plant 1/1/1 (EN)gineered safety feature 1 / 1 / 1 (control room system)

(L)ow-Power / Shutdown 1/1/1 (N)ew or (M)odified from bank including 1(A) 2/2/1 (P)revious 2 exams 3 / 3 / 2 (randomly selected)

(R)CA 1/1/1 (S)imulator

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: __PRAIRIE ISLAND_____________________ Date of Examination: SEPTEMBER 2018 Exam Level: SRO-U Operating Test No.: PI-ILT-NRC-18 Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System / JPM Title Type Code* Safety Function

a. NONE
b. NONE
c. RCS / RCP THERMAL BARRIER HX LEAK (RC-24SF) A, D, P, S 4P
d. STOP TDAFWP w/ ACCUMULATOR FAILURE (AF-21SF) A, EN, N, S, L 4S
e. NONE
f. NONE
g. PRM / SECURE R11/12 IN CONTROL ROOM (RM-5S) D, P, S 7
h. NONE In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. RCP SEAL ISOLATION AFTER LOSS OF ALL AC (RC-8) D, E, L, R 2
j. NONE
k. STARTUP PORTABLE BATTERY CHARGER (DC-1) D, E 6
  • All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room (D)irect from bank 9/8/4 (E)mergency or abnormal in-plant 1/1/1 (EN)gineered safety feature 1 / 1 / 1 (control room system)

(L)ow-Power / Shutdown 1/1/1 (N)ew or (M)odified from bank including 1(A) 2/2/1 (P)revious 2 exams 3 / 3 / 2 (randomly selected)

(R)CA 1/1/1 (S)imulator