ML22136A160

From kanterella
Jump to navigation Jump to search

Report Regarding November 15 - December 31, 2021, Regulatory Audit for Framatome Inc. Topical Report Anp 10340P, Revision 0, Supplement 1, Revision 0 Incorporation of Chromia-Doped Fuel Properties in Framatome PWR Methods
ML22136A160
Person / Time
Site: 99902041, PROJ0728
Issue date: 05/16/2022
From: Richard Chang
Licensing Processes Branch
To: Peters G
Framatome
Otto N, NRR/DORL/LLPB
Shared Package
ML22129A158 List:
References
EPID L-2021-TOP-0015
Download: ML22136A160 (3)


Text

OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION May 16, 2022 Mr. Gary Peters, Director Licensing and Regulatory Affairs Framatome, Inc.

3315 Old Forest Road Lynchburg, VA 24501

SUBJECT:

REPORT REGARDING NOVEMBER 15 - DECEMBER 31, 2021, REGULATORY AUDIT FOR FRAMATOME INC. TOPICAL REPORT ANP-10340P, REVISION 0, SUPPLEMENT 1, REVISION 0 INCORPORATION OF CHROMIA-DOPED FUEL PROPERTIES IN FRAMATOME PWR METHODS (EPID L-2021-TOP-0015)

Dear Mr. Peters:

By letter dated June 28, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21187A198), Framatome Inc. (Framatome) submitted to the U.S.

Nuclear Regulatory Commission (NRC), Topical Report (TR) ANP-10340P, Revision 0, Supplement 1, Revision 0, Incorporation of Chromia-Doped Fuel Properties in Framatome PWR [Pressurized Water Reactor] Methods, for review and approval. The TR is a supplement to the approved TR ANP-10340-PA, Revision 0, Incorporation of Chromia-Doped Fuel Properties in AREVA Approved Methods (ADAMS Package Accession No. ML18171A107), for the incorporation of chromia-doped fuel in Framatome approved methods, which dealt only with boiling water reactor (BWR) methodologies. This supplement documents the effects of the use of chromia-doped fuel and its implementation in Framatome PWR methodologies.

On November 15 through December 31, 2021, the NRC staff conducted a virtual regulatory audit to discuss supporting documentation and to ask questions about the review of TR ANP-10340P, Revision 0, Supplement 1, Revision 0, regarding the application of chromia-doped fuel. In addition, Microsoft Teams discussions were held on November 18 and December 7, 2021. The results of the audit provided additional information to support the NRC staff safety evaluation. The audit report is enclosed.

NOTICE: The enclosure to this transmittal letter has proprietary information, once this letter is separated from the enclosure it is decontrolled.

OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION Please contact Ngola Otto at 301-415-6695 or via e-mail at Ngola.Otto@nrc.gov with any questions you may have regarding this letter.

Sincerely,

/RA/

Richard Chang, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 99902041 Project No. 728

Enclosure:

Audit Report (Proprietary)

ML22129A158 (Package)

ML22136A160 (Letter)

ML22129A156 (Audit Report)

OFFICE NRR/DORL/LLPB/PM NRR/DORL/LLPB/LA NRR/DSS/SNSB/BC NRR/DORL/LLPB/BC NAME NOtto DHarrison SKrepel RChang DATE 05/09/2022 05/12/2022 05/16/2022 05/16/2022