Technical Letter Report TLR-RES/DE/REB-2022-04 Preliminary Assessment of Considerations for the Front-End Activities for Molten Salt Reactors Date: April 2022 Prepared in response to NMSS Information Assistance Request, by:
R. Torres*, J. Carlson, and W. Reed U.S. Nuclear Regulatory Commission
- Former NRC staff Division of Engineering Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
ii DISCLAIMER This report was prepared as an account of work sponsored by an agency of the U.S. Government.
Neither the U.S. Government nor any agency thereof, nor any employee, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for any third party's use, or the results of such use, of any information, apparatus, product, or process disclosed in this publication, or represents that its use by such third party complies with applicable law.
iii This report does not contain or imply legally binding requirements. Nor does this report establish or modify any regulatory guidance or positions of the U.S. Nuclear Regulatory Commission and is not binding on the Commission.
iv EXECUTIVE
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) has developed an overarching plan to support the licensing and certification activities for advanced non-light-water reactor (non-LWR) reactor technologies. The non-LWR Vision and Strategy Near-Term Implementation Action Plans (NRC, 2017) directly supports NRCs responsibilities under the Nuclear Energy Innovation Capabilities Act of 2017 (U.S. Congress, 2017), which includes objectives to enable civilian research and development of advanced nuclear energy technologies by private and public institutions, and to expand theoretical and practical knowledge of nuclear physics, chemistry, and materials science, among other purposes.
The NRCs Office of Nuclear Material Safety and Safeguards (NMSS) has been monitoring both the U.S. Department of Energy (DOE) and industrys activities related to the development of advanced non-LWR technologies, including those related to the potential licensing and certification of molten salt reactors (MSRs). To date, the NRC is aware of five commercial vendors that have expressed interest or have been actively engaged in the development and potential near-term licensing and certification of MSR technologies, namely:
the Integral Molten Salt Reactor under development by Terrestrial Energy USA, the Fluoride Salt-Cooled High Temperature Reactor under development by Kairos
- Power, the Lithium Fluoride Thorium Reactor under development by Flibe Energy, the Molten Chloride Fast Reactor under development by TerraPower and Southern Nuclear, and the Molten Salt Research Reactor under development by Abilene Christian University.
The objective of this report is to provide a preliminary assessment of potential technical and regulatory considerations related to the management of unirradiated (fresh) fissile and fertile fuel materials for these near-term MSR technologies, including activities related to their enrichment, production, and transportation to a reactor site (i.e., front-end activities). The preliminary assessment was structured to provide the following:
General background information related to prior experience on operating molten salt reactors, and their associated fuel enrichment, production and transportation operations (Section 2),
General background on near-term MSR technologies and associated fuel materials, and the current state of knowledge on fuel enrichment, production and transportation options considered by their commercial vendors (Section 3),
Preliminary assessment of potential technical and regulatory considerations related to the enrichment, production and transportation of fuel materials for near-term MSR technologies under development (Section 4), and Summary and recommendations for follow-on activities to support NMSS activities related to MSR fuel cycles (Section 5).
v ACKNOWLEDGMENTS The authors thank N. Hansing, T. Boyce, and R. Iyengar for their valuable support and encouragement during the course of the effort and for their comments on the manuscript. The authors also wish to thank B. Beasley, W. Kennedy, W. Jessup, A. Muniz, R. Rivera, M. Sutton and C. Van Wert for their review and input regarding near-term molten salt technologies.
vi TABLE OF CONTENTS Executive Summary................................................................................................................... iv Acknowledgments....................................................................................................................... v Table of Contents....................................................................................................................... vi List of Tables........................................................................................................................... viii List of Figures............................................................................................................................ ix Acronyms.................................................................................................................................... x Chemical Elements and Compounds......................................................................................... xi 1
Introduction......................................................................................................................... 1 1.1 Regulatory Driver......................................................................................................... 1 1.2 Report Objectives........................................................................................................ 2 2
Background and Prior Operating Experience...................................................................... 3 2.1 Molten Salt Reactors.................................................................................................... 3 2.2 Prior Operating Experience on Molten Salt Reactors................................................... 4 2.2.1 Aircraft Reactor Experiment.................................................................................. 4 2.2.2 Molten Salt Reactor Experiment............................................................................ 6 2.3 Prior Operating Experience on Enrichment and Production of......................................
Molten Salt Reactor Fuel-Salt Materials....................................................................... 7 2.4 Prior Experience on Unirradiated Molten Salt Reactor Fuel-Salt Materials................... 9 3
Near-Term Molten Salt Reactor technologies.....................................................................10 3.1 Terrestrial Energy - Integral Molten Salt Reactor........................................................13 3.1.1 Technology Description and Status......................................................................13 3.1.2 State of Knowledge on Fuel Enrichment, Fabrication, and.....................................
Transportation Options........................................................................................14 3.2 Kairos Power - Fluoride Salt-Cooled High Temperature Reactor................................14 3.2.1 Technology Description and Status......................................................................14 3.2.2 State of Knowledge on Fuel Enrichment, Fabrication, and.....................................
Transportation Options........................................................................................16 3.3 Flibe Energy - Lithium Fluoride Thorium Reactor.......................................................16 3.3.1 Technology Description and Status......................................................................16 3.3.2 State of Knowledge on Fuel Enrichment, Fabrication, and.....................................
Transportation Options........................................................................................18 3.4 TerraPower / Southern Nuclear - Molten Chloride Fast Reactor.................................18
vii 3.4.1 Technology Description and Status......................................................................18 3.4.2 State of Knowledge on Fuel Enrichment, Fabrication, and.....................................
Transportation Options........................................................................................19 3.5 Abilene Christian University - Molten Salt Research Reactor.....................................19 3.5.1 Technology Description and Status......................................................................19 3.5.2 State of Knowledge on Fuel Enrichment, Fabrication, and.....................................
Transportation Options........................................................................................20 4
Technical and Regulatory Considerations - Front-End Activities for Molten Salt Reactors.21 4.1 Technical Considerations for Fuel Enrichment, Production, and...................................
Transportation Methods..............................................................................................21 4.1.1 Uranium Tetrafluoride (UF4).................................................................................21 4.1.2 Uranium Trichloride (UCl3)...................................................................................26 4.1.3 Thorium Fluoride (ThF4).......................................................................................27 4.1.4 Tristructural Isotropic (TRISO) Solid Fuel.............................................................30 4.1.5 Non-Radioactive Salt Carriers and Coolants........................................................31 4.2 Regulatory Approaches and Safety Considerations....................................................33 5
Summary and Recommendations......................................................................................40 6
References........................................................................................................................45
viii LIST OF TABLES Table 2-1 Molten Salt Reactor Development Activities at Oak Ridge National Laboratory (Fredrickson et al., 2018)...................................................................................... 4 Table 2-2 Aircraft Reactor Experiment - Design Parameters and Relevant Dates (Rosenthal, 2010)..................................................................................................................... 5 Table 2-3 Molten Salt Reactor Experiment - Design Parameters and Relevant Dates (AEC, 1972)..................................................................................................................... 7 Table 2-4 Summary of Fluoride Procured for the MSRE (Shaffer, 1971)............................... 8 Table 3-1 Characteristics and Status of Molten Salt Reactor Technologies Under Commercial Development....................................................................................11 Table 4-1 Physical Properties of MSRE Coolant/Flush FLiBe Salts (Cantor et al., 1968).....32 Table 4-2 Safety Considerations for Production and Transportation of Molten Salt Reactor Fuels....................................................................................................................38
ix LIST OF FIGURES Figure 2-1 Schematic of ARE Core (Rosenthal, 2010).............................................................. 5 Figure 2-2 ARE Flow Diagram (Rosenthal, 2010)..................................................................... 6 Figure 3-1 Conceptual Design of Terrestrial Energys IMSR (Terrestrial, 2021a).....................13 Figure 3-2 Notional Design of FHRs TRISO-coated Particles Embedded in a Spherical Fuel Pebble (Kairos, 2020a).........................................................................................15 Figure 3-3 Graphical Description of an FHR TRISO-coated Particle (Kairos, 2020a)...............15 Figure 3-4. Conceptual design of the FHR (Kairos, 2020b).......................................................16 Figure 3-5 Conceptual Design of the LFTR (EPRI, 2015).........................................................17 Figure 3-6 Conceptual Design of the MCFR (TerraPower, 2021).............................................18 Figure 3-7 Conceptual design of the MSRR (Towell, 2020)......................................................20 Figure 4-1 UCO TRISO Particle (left) (Demkowicz et al., 2019) and Fuel Pebble (right)
(Mitchell et al., 2020)............................................................................................30 Figure 4-2 Applicability of Regulatory Frameworks to Front-End Activities for Molten Salt Reactors...............................................................................................................35
x ACRONYMS ADAMS Agencywide Documents Access and Management System ADU ammonium diuranate AEC U.S. Atomic Energy Commission ANP Aircraft Nuclear Propulsion ARDP Advanced Reactor Demonstration Program ARE Aircraft Reactor Experiment AUC ammonium uranyl carbonate DOE Department of Energy DOT Department of Transportation EPRI Electric Power Research Institute Euratom European Atomic Energy Commission FHR Fluoride Salt-Cooled High Temperature Reactor GAIN Gateway for Accelerated Innovation in Nuclear HALEU high-assay low-enriched uranium IAEA International Atomic Energy Agency IMSR Integral Molten Salt Reactor ISA integrated safety analyses LEU low-enriched uranium LFTR Lithium Fluoride Thorium Reactor LWR light-water reactor MCFR Molten Chloride Fast Reactor MCRE Molten Chloride Reactor Experiment MOSART Molten Salt Actinide Recycler and Transmuter MSBR Molten Salt Breeder Reactor MSR molten salt reactor MSRE Molten Salt Reactor Experiment MSRR Molten Salt Research Reactor NMSS Office of Nuclear Material Safety and Safeguards NNL National Nuclear Laboratory (UK)
NRC U.S. Nuclear Regulatory Commission OPG Ontario Power Generation ORNL Oak Ridge National Laboratory OSHA Occupational Safety and Health Administration PCP packaging certification program PEL permissible exposure limit RAMPAC Radioactive Materials Packaging (database)
RRIP Research Reactor Infrastructure Program SAMOFAR Safety Assessment of the Molten Salt Fast Reactor SMR small modular reactor SNM special nuclear material TRISO tristructural isotropic
xi CHEMICAL ELEMENTS AND COMPOUNDS Be beryllium BeF2 beryllium fluoride BeO beryllium oxide Bi bismuth BiCl3 bismuth chloride Br bromine C
carbon CCl4 carbon tetrachloride CClxF(4-x) freon C3Cl6 hexachloropropene C2H2 acetylene C3H6 propylene C6H12N4 hexamethylenetetramine CH4N2O urea CH3SiCl3 methyltrichlorosilane CO carbon monoxide CO2 carbon dioxide COCl2 phosgene Ca calcium CaCl2 calcium chloride Cd cadmium CdCl2 cadmium chloride Cl chlorine F
fluorine FLiBe salt mixture of LiF and BeF2 FLiNaK salt mixture of LiF, NaF, and KF H
hydrogen HBr hydrogen bromide (hydrobromic acid if aqueous)
HCl hydrogen chloride (hydrochloric acid if aqueous)
HF hydrogen fluoride (hydrofluoric acid if aqueous)
HI hydrogen iodide (hydroiodic acid if aqueous)
HNO3 nitric acid IPyC inner pyrolytic carbon KNO3 potassium nitrate LiF lithium fluoride MgCl2 magnesium chloride N
nitrogen NH3 ammonia NH4F ammonium fluoride NH4HF2 ammonium bifluoride Na sodium NaCl sodium chloride NaF sodium fluoride NaNO3 sodium nitrate NOx nitrogen oxide O
oxygen OPyC outer pyrolytic carbon Pb lead PbCl3 lead chloride Pu plutonium PuF3 plutonium fluoride PuO2 plutonium oxide Si silicon SiC silicon carbide Solar salt mixture of NaNO3 and KNO3 Th thorium ThF4 thorium fluoride Th(NO)3 thorium nitrate ThO2 thorium oxide (thoria)
Th(OH)4 thorium hydroxide ThOF2 thorium oxyfluoride TRISO tristructural isotropic U
uranium UC2 uranium dicarbide UCO uranium oxycarbide UCl3 uranium trichloride UF4 uranium tetrafluoride UF6 uranium hexafluoride UO2 uranium dioxide UO3 uranium trioxide U3O8 uranium oxide UO2(NO3)2 uranyl nitrate UO(OH)2 uranyl hydroxide UO2F2 uranyl fluoride UO2Cl2 uranyl chloride Zr zirconium ZrF4 zirconium tetrafluoride
1 1 INTRODUCTION 1.1 Regulatory Driver The U.S. Nuclear Regulatory Commission (NRC) has developed an overarching plan to support the licensing and certification activities for advanced non-light-water reactor (non-LWR) reactor technologies. The non-LWR Vision and Strategy Near-Term Implementation Action Plans (IAPs)
(NRC, 2017) directly support NRCs responsibilities under the Nuclear Energy Innovation Capabilities Act of 2017 (U.S. Congress, 2017), which includes as objectives to enable civilian research and development of advanced nuclear energy technologies by private and public institutions, and to expand theoretical and practical knowledge of nuclear physics, chemistry, and materials science, among other purposes.
The NRCs Office of Nuclear Material Safety and Safeguards (NMSS) has been monitoring both the U.S. Department of Energy and industrys activities related to the development of advanced non-LWR technologies, including those related to the potential licensing and certification of molten salt reactors (MSRs). To date, the NRC is aware of five (5) vendors that have expressed interest or have been actively engaged in the development and potential near-term licensing and certification of MSR technologies, namely:
the Integral Molten Salt Reactor under development by Terrestrial Energy USA, the Fluoride Salt-Cooled High Temperature Reactor under development by Kairos
- Power, the Lithium Fluoride Thorium Reactor under development by Flibe Energy, the Molten Chloride Fast Reactor under development by TerraPower and Southern Nuclear, and the Molten Salt Research Reactor under development by Abilene Christian University.
As part of its regulatory mission, NMSS has been particularly interested in the vendor-proposed plans for activities related to the front-end and back-end of MSR fuel cycles, including the enrichment, production and transportation of unirradiated (fresh) fissile and fertile fuel materials, and the storage and transportation of irradiated (spent) fuel and carrier salt materials. The timely understanding of potential technical and regulatory issues related to the licensing, certification, and operation of facilities and systems for materials management is an important component for supporting activities and timelines related to reactor licensing and operation.
2 1.2 Report Objectives The objective of this report is to provide a preliminary assessement of potential technical and regulatory considerations related to the management of unirradiated (fresh) MSR fissile and fertile fuel materials prior to reactor operations, including activities related to their enrichment, production, and transportation to a reactor site. The preliminary assessment was structured to provide the following:
General background information related to prior experience on operating molten salt reactors, and their associated fuel enrichment, production and transportation activities (Section 2),
General background on near-term MSR technologies and associated fuel materials, and the current state of knowledge on fuel enrichment, production and transportation options considered by their commercial vendors (Section 3),
Preliminary assessment of potential technical and regulatory considerations related to the enrichment, production and transportation of fuel materials for near MSR technologies under development (Section 4), and Summary and recommendations for follow-on activities to support NMSS activities related to MSR fuel cycles (Section 5).
3 2 BACKGROUND AND PRIOR OPERATING EXPERIENCE 2.1 Molten Salt Reactors The concept of a homogeneous, molten salt-cooled nuclear reactor was first envisioned in 1948 when scientists were evaluating high temperature fluid-fueled reactors that are not constrained by the limitations of solid fuels and conventional coolants (Williams, et al., 2017). Molten salt reactor (MSR) concepts are based on using a molten salt mixture as a primary nuclear reactor coolant, while the fuel can be either directly dissolved in the coolant (i.e., liquid-fueled) or can be in a separate solid form (i.e., salt-cooled). MSRs can be operated in either thermal or fast neutron spectra, as simple fissile convertors or breeder reactors (e.g., utilizing both fissile and fertile fuels), as well as accelerator-driven sub-critical reactors or transuranic element burners.
Molten salt coolants have very high heat capacities and heat transfer properties, as well as being thermally and radiation stable, which make them suitable coolants compared to water used in current light-water reactors (LWRs) (Le Brun, 2007). Their high boiling point and low vapor pressures allow for reactor operation at lower pressure (i.e., atmospheric) and higher temperature than current light-water reactor technologies. This, in turn, provides increased power conversion efficiencies (approximately 50 percent more kWh(e)) due to the higher thermal efficiency.
MSRs provide additional inherent safety relative to current LWR technologies (Elsheikh, 2013).
The fuel-salt mixtures used in fluid-cooled MSRs exhibit large negative temperature coefficients of reactivity due to their high thermal expansion; therefore, if the reactor overheats, the reactivity in the core slows down. In addition, the core unit does not require active engineered safety systems for decay heat removal (i.e., MSRs rely on passive cooling). Since the fuel-salt mixture is in liquid form, during a design-basis accident it can be quickly drained out of the reactor into a passively cooled dump tank. MSR designs can implement an actively-cooled salt plug at the bottom of the core kept at a temperature below the freezing point of the salt. If the reactor core temperature rises beyond a critical point, the plug melts, and the liquid fuel is immediately evacuated, pouring into a sub-critical geometry in a catch basin. Finally, since MSRs operate at atmospheric pressure and use no coolant water, the risk of a steam or hydrogen-led explosion during a design-basis accident is not credible.
Liquid-fueled MSRs also allow for increased flexibilities for fissile and fertile material utilization through continuous fission product removal via physical and pyrochemical processes. The fuel composition can be periodically adjusted online to minimize outages. Significant research efforts are focused on reactor design and supplementing thermodynamic and electrochemical data of fuel-salt halide mixtures, particularly those based on chlorides.
4 2.2 Prior Operating Experience on Molten Salt Reactors Oak Ridge National Laboratory (ORNL) has historically led efforts to support the development of MSR technologies, as shown in Table 2-1, with two designs being built and operated (Fredrickson et al., 2018). The following discussion provides a brief overview of those technologies and associated front-end activities for the enrichment, production, mixing, and transportation of their fuel-salt mixtures.
Table 2-1 Molten Salt Reactor Development Activities at Oak Ridge National Laboratory (Fredrickson et al., 2018)
Aircraft Nuclear Propulsion Program (1949 - 1961)
Aircraft Reactor Experiment: 2.5 MWt operated Aircraft Reactor Test: 60 MWt proposed Two-Fluid Molten Salt Breeder Reactor (1961 - 1970)
Molten Salt Breeder Reactor: 1,000 MWe design Molten Salt Reactor Experiment (1960 - 1975) 8 MWt operated Molten Salt Converter Reactor (1961 - 1965) 1,000 MWe design Molten Salt Breeder Experiment (1969 - 1970) 150 MWt proposed Molten Salt Reactor Demonstration (1972) 350 MWe proposed Single-Fluid Molten Salt Breeder Reactor (1969 - 1978) 1,000 MWe design Denatured Molten Salt Reactor (1977 - 1980) 1,000 MWe design 2.2.1 Aircraft Reactor Experiment The Aircraft Nuclear Propulsion (ANP) project at ORNL was established in 1949, at the request of the Atomic Energy Commission (AEC), to provide technical support to the Air Forces efforts on propulsion of supersonic aircraft (Cottrell et al., 1955). In response to the ANP, ORNL proposed to design and operate a reactor, named the Aircraft Reactor Experiment (ARE) in which a molten metal would flow through the core and then through a heat exchanger where it would heat the air for propulsion.
The ARE reactor assembly consisted of an Inconel pressure shell in which beryllium oxide (BeO) moderator and reflector blocks were stacked around fuel tubes, reflector cooling tubes, and control assemblies. The reactor core relied on sodium metal as coolant for the reflector and pressure shell as well as heat transfer medium by which moderator heat was readily transmitted to the fuel stream. The excess heat was removed from the sodium metal via a heat exchanger.
The fuel was a mixture of sodium fluoride (NaF) and zirconium tetrafluoride (ZrF4), with sufficient uranium tetrafluoride (UF4) added to make the reactor critical (see Table 2-2). Figure 2-1 and Figure 2-2 show a schematic and flow diagram for the ARE core. The design and operation of the ARE is extensively described by Cottrell et al. (1955). The ARE was operated from November 3-12, 1954 for a total of 96 MWh. The ANP project was abruptly terminated in June 1961.
5 Table 2-2 Aircraft Reactor Experiment - Design Parameters and Relevant Dates (Rosenthal, 2010)
Maximum Power (Thermal) 2.5 MWt Fuel-Salt 53 percent NaF, 41 percent ZrF4, 6 percent UF4 (93 percent enriched 235U)
Fuel Melting Point 532 °C [990 °F]
Fuel Inlet Temperature 663 °C [1225 °F]
Fuel Outlet Temperature 860 °C [1580 °F] (882 °C [1620 °F] at peak)
Fuel Flow Rate 45 gal/min [2.8 L/s]
Moderator BeO hexagonal blocks, 3.6 in. across x 6 in. high with 1.25 in. coolant passages Coolant Helium to water Reactor Vessel Material Inconel Critical November 3, 1954 Shut Down November 12, 1954 Figure 2-1 Schematic of ARE Core (Rosenthal, 2010).
6 Figure 2-2 ARE Flow Diagram (Rosenthal, 2010).
2.2.2 Molten Salt Reactor Experiment In 1956, following ARE operation, ORNL began to study the application of molten salt reactors for power station generation under the Civilian Nuclear Power Program. ORNL evaluated the technical feasibility and associated costs for both a single-fluid (fissile) system and a two-fluid (fissile/fertile) breeder system. ORNL pursued the design of a single-fluid fissile system to minimize design complexities. In 1960, the design for the Molten Salt Reactor Experiment (MSRE) began under the Molten Salt Reactor Program (MSRP). The MSRE was an eight megawatt-thermal (MWt) single-fluid test reactor, which operated successfully for over 17,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> between 1965 and 1969 (Rosenthal et al., 1970; Haubenreich, et al., 1970; Peretz, 1996).
The reactor used a primary molten fluoride mixture of UF4 fuel in a carrier salt composed of lithium fluoride (LiF), beryllium fluoride (BeF2), and zirconium tetrafluoride (ZrF4). The fuel-salt mixture circulated through the reactor vessel with a prismatic structure of unclad graphite moderator, a fuel-salt pump, and primary heat exchanger. The reactor vessel and piping components were made of Hastelloy N, a high strength nickel base alloy developed under the ANP Program (AEC, 1972). Heat was transferred from the fuel-salt mixture to a secondary coolant salt (LiF:BeF2, 2:1 mole ratio) in the primary heat exchanger. The coolant salt passed from the primary heat exchanger to an air-cooled radiator, a coolant salt pump, and then returned to the primary heat exchanger.
The MSRE operated between June 1, 1965 and December 12, 1969 for a total of 105 GWh.
The test demonstrated that fluoride salts in a liquid fuel are invulnerable to radiation-induced or thermal-induced degradation at the operating temperatures. The experiment also identified technical considerations related to the core performance of graphite and Hastelloy N components (AEC, 1972). Table 2-3 provides design and fuel parameters, as well as relevant dates for the MSRE.
7 Table 2-3 Molten Salt Reactor Experiment - Design Parameters and Relevant Dates (AEC, 1972)
Maximum Power (Thermal) 8 MWt Fuel Processing Method Batch, off-line Fuel/Carrier Salts 7LiF (65 mole percent) - BeF2 (29.1 mole percent) - ZrF4 (5.0 mole percent) - UF4 (0.9 mole percent) (nominal) 99.99 percent isotopically pure 7LiF Fuel concentrate: 7LiF (73 mole percent) - UF4 (27 mole percent)
Enrichment compositions:
235U (20 percent) : 238U (80 percent) 233U (80 percent) : 235U (20 percent) 239Pu as PuF3 Coolant/Flush Salts 7LiF:BeF2 (2:1 mole ratio)
Fuel Outlet Temperature 654°C [1210 °F]
Fuel Flow Rate 1200 gal/min [75.7 L/s]
Moderator Graphite (unclad, unsealed)
Secondary Coolant Salt 7LiF-BeF2 (2:1 mole ratio)
Reactor Vessel Material Hastelloy N Design Initiated July 1960 Critical with 235U Fuel June 1, 1965 Critical with 233U Fuel October 2, 1968 Hours Critical 15,655 Shut Down December 12, 1969 2.3 Prior Operating Experience on Enrichment and Production of Molten Salt Reactor Fuel-Salt Materials ORNL developed techniques and procedures for preparing and handling molten salts since 1953, which were implemented during support of the ANP project for the preparation of fluoride mixtures and their loading into the ARE. The molten salt production facility was operated by the Reactor Chemistry Division as an integral part of the MSRP to provide fused fluoride mixtures for its chemical and engineering tests (Shaffer, 1971). The facility also developed procedures for handling operations, including filling, sampling, and emptying engineering test loops.
The fluoride production facility had two processing units operating as a batch process, each with a capacity of about two cubic feet of fused salt per batch. Since commercial sources of fused fluoride mixtures that would meet MSRE specifications were not available, the production plant was adapted to support the repetitive preparation of fluoride mixtures of diverse chemical compositions to support engineering tests and the MSRE operation.
8 Fluoride-based feed materials for the MSRE primary fuel-salt, secondary coolant salt, and flush salts were purchased from commercial sources or otherwise obtained from the AEC, as summarized in Table 2-4 (Shaffer, 1971).
Table 2-4 Summary of Fluoride Procured for the MSRE (Shaffer, 1971)
Fluoride Salt Estimate (lb)
Procured (lb)
Source 7LiF 12,476 22,000 AEC BeF2 11,055 12,000 Commercial ZrF4 2,283 2,300 Commercial 238UF4 523 529 AEC 235UF4 246 263 AEC Lithium Fluoride (LiF) - The material was sourced as a hydroxide from the AEC and was later converted to fluoride at the production facility in the Y-12 National Security Complex. To minimize neutron absorption cross section, all LiF produced had an isotopic assay of at least 99.99 percent 7Li.
Uranium tetrafluoride (UF4) - Although the MSRE operated on a fuel mixture with UF4 enriched to 32 percent 235U, the material provided by the AEC was highly enriched to 93 percent 235U. About 90 kilograms of 235U was procured directly as UF4. The balance of the uranium inventory added to the MSRE fuel charge was depleted 235U.
Zirconium tetrafluoride (ZrF4) - Hafnium-free (<50 ppm) ZrF4 was procured from commercial sources to minimize neutron absorption penalties.
Beryllium fluoride (BeF2) - BeF2 of best-commercial purity per MSRE chemical specifications was obtained from commercial sources.
The production method for fluoride mixtures was generally independent of fluoride mixture composition provided that the liquidus temperature was within the capability of the process equipment. The production of multicomponent mixtures, however, was facilitated by the preparation and subsequent combination of simpler binary or ternary mixtures. Aside from the physical mixing of salts to obtain lower liquidus temperatures, the production process allowed for further purification of the resultant molten fluoride mixture. The removal of a limited number of impurity species (e.g., oxides, sulfates) during the production operation was achieved by treatment of the fluoride melt with anhydrous hydrogen fluoride (HF), hydrogen (H2), and, in some instances, strong metallic reducing agents. Volatile impurities were removed in the process gas effluent stream, and insoluble particulates were removed by decantation and filtration.
The production facility for fluoride mixtures was constructed on a 40- by 40-ft area in the high bay of Building 9201-3 within the Y-12 National Security Complex. To meet industrial hygiene requirements for handling beryllium and other toxic fluoride salts, the facility was enclosed and equipped with an air ventilation and filtration system (air flow rate of 14,000 cubic feet per
9 minute). The air flow maintained the atmosphere of the production facility at a negative pressure with respect to the outside area to control airborne contamination. Specific work areas within the production plant were compartmented and provided with direct exhaust air ducts and filtered makeup air. The exhaust air was filtered prior to discharge outside the building.
Fused fluoride mixtures and the enriched fuel concentrate were produced in two batch processing units. Additional details on the operations are provided in Shaffer (1971).
2.4 Prior Experience on Unirradiated Molten Salt Reactor Fuel-Salt Materials Very limited information is available on the transportation activities in support of the ARE and MSRE. MSREs activities for production of enriched uranium concentrate and fused fluoride mixtures occurred in different buildings at the Y-12 National Security Complex (Shaffer, 1971).
After processing, the fuel-salt mixtures were transferred to a storage container and placed in a nuclear-safe transport container and shipped to a security warehouse within the Y-12 national security complex. Information related to these activities has not been identified.
10 3 NEAR-TERM MOLTEN SALT REACTOR TECHNOLOGIES The landscape for molten salt reactor (MSR) technologies is one of the most diverse for Generation IV nuclear power plants with a large number of vendors announcing plans or activities in support of their development. The U.S. Department of Energy (DOE) has also provided funding to support research and resolution to important technical issues for demonstrating adequate safety for operation of some of the designs. The U.S. Nuclear Regulatory Commission (NRC) is currently aware of five (5) vendors with the potential to pursue near-term licensing and certification activities for MSR technologies, including:
the Integral Molten Salt Reactor under development by Terrestrial Energy USA, the Fluoride Salt-Cooled High Temperature Reactor under development by Kairos
- Power, the Lithium Fluoride Thorium Reactor under development by Flibe Energy, the Molten Chloride Fast Reactor under development by TerraPower and Southern Nuclear, and the Molten Salt Research Reactor under development by Abilene Christian University.
Table 3-1 compiles information on the characteristics and status of these MSR technologies.
This section provides background on the designs and status of these near-term technologies, including the current state of knowledge for the enrichment, production, and transportation of their fuel materials.
The scope of this report excludes additional commercial vendors that have publicly communicated plans to develop other MSR technologies but have not yet engaged with the NRC on pre-application engagements. These include:
the Stable Salt Reactor under development by Moltex Energy, the Molten Chloride Salt Fast Reactor under development by Elysium Industries, the Thorium Molten Salt Reactor 500, under development by ThorCon Power, the Mu*STAR Accelerator-Driven Small Modular Reactor, under development by Muons, Inc., and the Micro Molten Salt Reactor (ARC Generator) under development by Alpha Tech Research Corp.
In addition, multiple international organizations and countries are developing MSR technologies, such as the Molten Salt Fast Reactor (SAMOFAR) project funded by European Atomic Energy Commission (Euratom), the Molten Salt Actinide Recycler and Transmuter (MOSART) concept explored by the Russian Federation, the Thorium-Fueled Liquid Fluoride MSR to be operated by the Peoples Republic of China, and the Thorium-Fueled Molten Salt Breeder Reactor designed by the Republic of India. The scope of this report excludes an assessment of these efforts and associated activities related to the enrichment, production, and transportation of fuel-salt mixtures.
11 Table 3-1 Characteristics and Status of Molten Salt Reactor Technologies Under Commercial Development Technology Integral Molten Salt Reactor (IMSR)
(Hill, 2020)
Molten Fluoride Salt-Cooled High Temperature Reactor (FHR) (Kairos, 2020b)
Lithium Fluoride Thorium Reactor (LFTR)
(EPRI, 2015)
Molten Chloride Fast Reactor (MCFR)
[Collaboration with Southern Company]
(Latkowski, 2021)
Molten Salt Research Reactor (MSRR)
(Schubert, 2020)
Commercial Vendor Terrestrial Energy USA Kairos Power Flibe Energy TerraPower Abilene Christian University Base Model Output (MWe, MWt) 195 MWe; 442 MWth 140 MWe 250 MWe; 600 MWth 500-1200 MWe (grid-scale);30-300 MWe (mid-scale) 1 MWth Neutron Spectrum Thermal Thermal Thermal Fast Thermal Moderator Graphite Graphite1 Graphite Multiple materials under consideration4 Graphite Heat Transfer Medium Molten fluoride salt Molten fluoride salt Molten fluoride salt Molten chloride salt Molten fluoride salt Outlet Temperature 700 °C [1292 °F]
650 °C [1202 °F]
650 °C [1202 °F]
Unknown Unknown Thermal Efficiency 44 percent 45 percent (net) 42 percent (net)
Unknown Unknown Fuel Enrichment (235U)
<5 percent 19.75 percent None
~12 percent 19.9 percent Fuel Composition Fluoride salt TRISO (uranium oxycarbide)
Primary: UF4 (233U)
Blanket: ThF4 (232Th)
Chloride salt UF4 Salt Coolant Composition Proprietary fluoride salt Primary salt: FLiBe2 (enriched with 7Li)
Secondary salt: Solar Primary and secondary salt: FLiBe Proprietary chloride salt Primary salt: FLiBe (enriched with 7Li)
Secondary salt: Unknown Initial Reactor Demonstration / Siting Unknown Low-power demonstration reactor at the East Tennessee Technology Park (ETTP) in Oak Ridge (Hermes Reactor) expected to be operational in 20263.
Unknown The small-scale Molten Chloride Reactor Experiment will be located at the Idaho National Laboratory site and will inform the design of a small to mid-scale MCFR demonstration reactor Test reactor expected to be sited at Abilene, Texas.
DOE Support U.S. Industry Opportunities for Advanced Nuclear Technology Development ADRP Risk-Reduction Awardee ARDP Pathway Awardee; GAIN voucher ADRP Risk-Reduction Awardee RRIP Awardee DOE Laboratory Partner Argonne National Laboratory Oak Ridge National Laboratory Pacific Northwest National Laboratory Idaho National Laboratory Undecided
12 Technology Integral Molten Salt Reactor (IMSR)
(Hill, 2020)
Molten Fluoride Salt-Cooled High Temperature Reactor (FHR) (Kairos, 2020b)
Lithium Fluoride Thorium Reactor (LFTR)
(EPRI, 2015)
Molten Chloride Fast Reactor (MCFR)
[Collaboration with Southern Company]
(Latkowski, 2021)
Molten Salt Research Reactor (MSRR)
(Schubert, 2020)
NRC Status Pre-application engagement. Regulatory engagement plan submitted 10/2021.
Construction Permit application for test reactor accepted for docketing and review in 11/2021. Pre-application engagement for power reactor project -
several topical reports approved and more under review.
Pre-application engagement (limited).
Pre-application engagement (limited).
Pre-application engagement. Preparing a regulatory engagement plan following a public meeting held in 11/2021.
Construction Permit application expected end of FY22.
1 (Kairos, 2020a) 2 (Hastings, 2020) 3 (Haugh, 2021) 4 (TerraPower, 2020)
13 3.1 Terrestrial Energy - Integral Molten Salt Reactor 3.1.1 Technology Description and Status The Integral Molten Salt Reactor (IMSR) is a thermal-spectrum liquid-fueled small MSR design with 195 megawatt-electric (MWe) base model output (scalable to 390 MWe). The IMSR is based on the Molten Salt Reactor Experiment (MSRE) operated by Oak Ridge National Laboratory (ORNL) with the use of similar core unit components and fuel-salt mixtures. The graphite-moderated molten fluoride salt reactor uses low-enriched uranium (LEU) in a fluoride-based homogeneous primary salt mixture (Hill, 2020).
Figure 3-1 Conceptual Design of Terrestrial Energys IMSR (Terrestrial, 2021a).
The reactor design features a completely sealed reactor vessel (core unit) with integrated pumps, heat exchangers and shutdown rods (Figure 3-1). The core unit is anticipated to be replaced completely as a single unit at the end of its useful service life (nominally 7 years) with a plant design-life of eight cycles (nominally 56 years). In the integral process within the core unit, the primary fissile fuel-salt mixture is pumped through a graphite moderator and then through the integral heat exchangers to transfer its heat to the secondary loop. The secondary loop contains a non-fissile coolant salt mixture, which transfers heat away from the primary heat exchangers to a tertiary salt loop that powers a steam generator. The core unit is designed to allow for continuous/periodic addition of fissile material that does not require opening or shut down for refueling.
The fissile fuel material for the IMSR is LEU, with enrichments between 2 - 3 percent 235U at reactor startup and 4.95 percent 235U for periodic fuel additions (Hill, 2020). The primary molten salt used for mixing with the fuel is a fluoride-based proprietary coolant salt.
14 Terrestrial Energy USA, Inc. (TEUSA) is currently engaged in pre-application activities with the NRC in support of a future application for a Standard Design Approval of the IMSR core unit under 10 CFR Part 52. TEUSA is an affiliate of Terrestrial Energy Inc. (TEI) and has entered into agreements with TEI to support TEUSAs development and deployment program for the IMSR in the U.S.
3.1.2 State of Knowledge on Fuel Enrichment, Fabrication, and Transportation Options Terrestrial Energy recently announced an agreement with Westinghouse and the United Kingdoms National Nuclear Laboratory (NNL) to support the IMSRs fuel supply needs (Terrestrial, 2021b). NNL will support Westinghouses Springfields Fuels production facility in Lancashire, England. A review of information submitted to the NRC has not identified specific details on plans for enrichment, fabrication, and transportation options under consideration for the IMSR, though docketed information indicates that TEUSA will use low-enriched fuel.
3.2 Kairos Power - Fluoride Salt-Cooled High Temperature Reactor 3.2.1 Technology Description and Status The Fluoride Salt-Cooled High Temperature Reactor (FHR) is a thermal-spectrum solid-fueled MSR design with 140 MWe base model output to operate at near atmospheric pressure using solid fuel within a molten fluoride salt coolant. The KP-FHR solid fuel design is based on spherical pebble fuel elements embedded with tristructural isotropic (TRISO) graphite-matrix coated particles (Kairos, 2020a). TRISO-based fuels were initially developed and successfully implemented for high temperature gas-cooled reactors.
The FHR pebble fuel element design contains a central sub-dense inner core surrounded by an annular layer of TRISO particles packed into a partially-graphitized matrix material (fuel pebble annulus) and covered by an outer shell of fuel-free matrix material (Figure 3-2) (Kairos, 2020a).
Each TRISO particle is composed of a fissile kernel enriched with 19.75 percent 235U in the form of a heterogeneous mixture of uranium oxide and uranium carbide (UCO) surrounded by successive coating layers of a porous carbon buffer layer, a dense inner pyrolytic carbon (IPyC) layer, a silicon carbide (SiC) layer, and a dense outer pyrolytic carbon (OPyC) layer (Figure 3-3). The TRISO particles are overcoated with resinated graphite powder, which are pressed and heat-treated to become the fuel matrix material in the fuel pebble annulus (Kairos, 2020b).
15 Figure 3-2 Notional Design of FHRs TRISO-coated Particles Embedded in a Spherical Fuel Pebble (Kairos, 2020a).
Figure 3-3 Graphical Description of an FHR TRISO-coated Particle (Kairos, 2020a).
The primary reactor coolant is a molten fluoride salt mixture commonly referred to as FLiBe (7LiF:BeF2 at a nominal 2:1 mole ratio), which also provides retention of fission products that escape the TRISO fuel particle and pebble barriers. This is the same salt mixture used as the intermediate coolant in the MSRE. LiF2 generally requires a very high purity of 7Li since the other naturally occurring isotope 6Li has a high neutron absorption cross section. BeF2 is chemically toxic but is desired for its advantageous neutronic and physical properties.
Figure 3-4 provides a schematic of the conceptual design for the FHR. A primary coolant loop circulates the FLiBe salt mixture using pumps and transfers the heat to an intermediate coolant loop via a heat exchanger. The pumped flow intermediate coolant loop utilizes a solar nitrate salt compatible with reactor coolant, which transfers heat from the reactor coolant to the power conversion system through a steam generator. The design includes two decay heat removal systems. One normal decay heat removal system is used following normal shutdowns and anticipated operational occurrences. A separate passive decay heat removal system, which along with natural circulation in the reactor vessel, removes decay heat in response to a design-basis accident and does not rely on electrical power.
16 Figure 3-4. Conceptual design of the FHR (Kairos, 2020b).
Kairos Power has partnered with the Tennessee Valley Authority to eventually deploy a test reactor demonstration of the FHR (named the Hermes test reactor) at the East Tennessee Technology Park in Oak Ridge, Tennessee. The 35-MWth Hermes test reactor is being funded by the DOE Advanced Reactor Demonstration Program (ARDP) under the risk-reduction development pathway and is expected to be operational by 2026. Kairos Power has submitted a construction permit application for the Hermes test reactor and plans to submit an operating license application under 10 CFR Part 50. The Hermes test reactor is expected to be operational in 2026 (Haugh, 2021).
3.2.2 State of Knowledge on Fuel Enrichment, Fabrication, and Transportation Options A review of information submitted to the NRC has not identified specific details on plans for enrichment, fabrication, and transportation options under consideration for the FHR.
3.3 Flibe Energy - Lithium Fluoride Thorium Reactor 3.3.1 Technology Description and Status Flibe Energys Lithium Fluoride Thorium Reactor (LFTR)0F1, designed for both power and isotope production, is a liquid-fueled, graphite-moderated thermal-spectrum breeder reactor optimized for operation on a thorium-supported 233U fuel cycle (EPRI, 2015). The reference design has a 1The reactor was rebranded in 2021 as the "Lithium Fluoride Thorium Reactor (LFTR)", with "Lithium" replacing "Liquid".
17 nominal power output of 600 MWth and 250 MWe. The core, blanket, and primary cooling salt loops are all operated at or near atmospheric pressure and without steam for the blanket. The reactor is designed to breed fuel by converting 232Th in the blanket salt into fissile 233U through neutron absorption in an operational reactor fueled with existing fissile 233U material. Throughout the reactor lifecycle, 233U is extracted from the blanket salts and fed back into the reactor core to perpetuate the fuel production cycle (Harris, 2015).
Figure 3-5 below depicts the conceptual LFTR design and shows how the heat generated in the reactor core is transferred via heat exchangers to a clean secondary coolant salt loop that exits the containment boundary and is transferred to the working fluid of a gas turbine engine to generate power. The Flibe Energy LFTR design uses a supercritical carbon dioxide (CO2)
Brayton cycle power conversion system to achieve greater thermal efficiency (EPRI, 2015).
Figure 3-5 Conceptual Design of the LFTR (EPRI, 2015).
Flibe Energys LFTR has the most unique fuel forms of near-term MSR designs since instead of the more traditional 235U fissile material, 233U is used in the primary fuel-salt and 232Th is used for the blanket salt that provides the subsequent fissile material. Flibe Energy has no needs for enrichment of 233U. The fissile and fertile materials for the fuel and blanket salts are in the form of UF4 and ThF4, respectively. The fuel-salt and blanket salt use FLiBe and consist of 2LiF2-BeF2-XF4, where X is 233U for the fuel and 232Th for the blanket (EPRI, 2015). FLiBe is a chemically stable, ionically bonded salt that mitigates radiation damage and retains a majority of fission products by reacting to form stable fluoride salts that are retained in the mixture under normal operations and accident conditions (Flibe, 2021).
18 Flibe Energy and Pacific Northwest National Laboratory were funded under DOEs Industry Funding Opportunity Announcement (FOA) to study the use of nitrogen trifluoride to remove uranium from the molten salt-fuel mixtures as a preliminary step for fission product removal.
3.3.2 State of Knowledge on Fuel Enrichment, Fabrication, and Transportation Options A review of information submitted to the NRC has not identified specific details on plans regarding fabrication or transportation options under consideration for the LFTR. Flibe Energy has no needs for encrichment of 233U.
3.4 TerraPower / Southern Nuclear - Molten Chloride Fast Reactor 3.4.1 Technology Description and Status TerraPowers Molten Chloride Fast Reactor (MCFR) is a fast-spectrum molten salt reactor with a molten chloride salt serving as both the fuel and the coolant. The MCFR demonstration reactor is designed as a small to mid-scale reactor with an output of 30-300 MWe, and the final commercial grid-scale reactor will produce electricity in the range of 500-1200 MWe (Latkowski, 2021). The fast spectrum improves the neutron economy and largely mitigates the fission product poisoning that normally necessitates online reprocessing capabilities.
Figure 3-6 shows the conceptual design for the MCFR. The reflector in this design can potentially change throughout the fuel cycle, beginning with a heavier fast neutron reflector (e.g., lead, lead oxide, lead bismuth, tungsten) and shifting to include a lighter neutron reflector/moderator (e.g., graphite, beryllium, lithium, zirconium hydride, non-graphite carbon)
(TerraPower, 2020).
Figure 3-6 Conceptual Design of the MCFR (TerraPower, 2021).
19 In December 2020, the U.S. Department of Energy selected the Molten Chloride Reactor Experiment (MCRE) proposal, with Southern Company as the Prime, as a winner of the Advanced Reactor Demonstration Program risk-reduction pathway. This effort is relevant to TerraPowers MCFR design.
Southern Company and TerraPower are working on an Integrated Effects Test (IET) to learn how the MCFR technology will scale and behave at larger, commercially relevant sizes. The IET is expected to be commissioned and begin operating in TerraPowers Everett, Washington, facility in 2022.
3.4.2 State of Knowledge on Fuel Enrichment, Fabrication, and Transportation Options A review of information submitted to the NRC has not identified specific details on plans for enrichment, fabrication, and transportation options under consideration for the MCFR.
3.5 Abilene Christian University - Molten Salt Research Reactor 3.5.1 Technology Description and Status The Abilene Christian University (ACU) Molten Salt Research Reactor (MSRR) is a graphite-moderated fluoride salt test reactor designed for a thermal power of 1 MWth. The reactor primary system will be configured in a loop, with a reactor vessel, a heat exchanger, a fuel pump, and experimental access points. A secondary loop will be used to remove the reactor thermal power, and the final heat sink will be air (Towell, 2020).
The MSRR is essentially a simplified version of the MSRE operated by ORNL. The major differences of the MSRR relative to the MSRE is that the reactor will be fueled with HALEU instead of high enriched uranium (HEU), it will have a lower power density, and it will not need cooling water within the containment (Towell, 2020).
Figure 3-7 shows a conceptual design for the MSRR.
The reactor containment vessel will be approximately 20 feet tall and 10 feet in diameter. The reactor vessel inside the containment vessel will be approximately 6 feet tall and 4.5 feet in diameter and will be surrounded by a 6-inch internal concrete shield. The reactor containment vessel is located in a below-grade trench within the facility. The lower reactor containment vessel head is surrounded by a small pool of water to remove decay heat under normal and accident conditions including loss of normal electrical power (Schubert, 2020).
20 Figure 3-7 Conceptual design of the MSRR (Towell, 2020).
The baseline fuel-salt composition for the MSRR is a mixture of lithium fluoride (LiF), beryllium fluoride (BeF2), and HALEU fuel in the form of uranium tetrafluoride (UF4). The lithium will be enriched to greater than 99.99 percent 7Li. The MSRR will use approximately 300 kg of nearly 20 percent (~19.9 percent) HALEU fuel (Schubert, 2020).
ACU has completed Phase 1 and is in Phase 2 of their project, which consists of designing and building a large, advanced molten salt system with advanced instrumentation and monitoring capabilities for the testing of the individual components that will be used in the MSRR (Towell, 2020).
The MSRR project is being carried out under a cooperative fuel agreement with the U.S.
Department of Energy's Research Reactor Infrastructure Program (RRIP) and supported through a collaboration with major U.S. industry partners, national laboratories, and universities.
Natura Resources, LLC, is partnering in a $30.5 million effort to design and license the research reactor in collaboration with a consortium of universities that includes ACU, University of Texas, Texas A&M University, and Georgia Institute of Technology (Schubert, 2020).
3.5.2 State of Knowledge on Fuel Enrichment, Fabrication, and Transportation Options ACU plans on the fuel coming on-site premixed and ready to be loaded into the core (Schubert, 2020). However, details on their plans for sourcing or transportation to the site have not been provided.
21 4 TECHNICAL AND REGULATORY CONSIDERATIONS -
FRONT-END ACTIVITIES FOR MOLTEN SALT REACTORS The enrichment, production and transportation of fuel and salt materials to support operation of near-term molten salt reactors (MSRs) present distinct technical and regulatory challenges relative to uranium oxide based fuels used in current light-water reactor technologies. The fuel-salt mixtures will be a combination of fissile and/or fertile materials of LEU or other isotopic (233U, 232Th) compositions with non-radioactive diluent or carrier salts. Fluoride salt-fueled reactors are expected to operate with uranium tetrafluoride (UF4) and thorium fluoride (ThF4), if fertile material is used, dissolved in molten fluoride coolant salts of various composition.
Similarly, the chloride salt-fueled reactors could potentially operate on uranium trichloride (UCl3) in various chloride salts. Fluoride salt-cooled reactors are designed to operate with a fluoride salt-based coolant but with a solid pebble fuel based on tristructural isotropic (TRISO) particles.
This section provides a preliminary assessment of technical and regulatory considerations for the enrichment, production, and transportation activities necessary to support near-term MSR technologies discussed in Section 3 of this report. The discussion provides a description of potential methods and approaches for these activities, associated safety considerations, and an initial assessment of the regulatory frameworks to support approval of these approaches by the U.S. Nuclear Regulatory Commission (NRC).
4.1 Technical Considerations for Fuel Enrichment, Production, and Transportation Methods 4.1.1 Uranium Tetrafluoride (UF4) 4.1.1.1 235U Enrichment Near-term MSR technologies are based on LEU fuel compositions (i.e., uranium weight percent of 235U less than 20 percent, as defined in 10 CFR Part 50). Three of the technologies will need higher enrichments than current light-water reactor solid oxide fuels (i.e., uranium weight percent of 235U exceeding 5 percent), which is commonly referred to as high-assay low-enriched uranium (HALEU).
To support industrys needs, the U.S. DOE established the HALEU Demonstration Program in collaboration with Centrus Energy, to deploy a small cascade of AC-100M enrichment centrifuges to demonstrate the capability to produce HALEU. In June 2021, the NRC approved a license amendment request for their American Centrifuge Plant at Piketon, Ohio, to begin production of LEU in early 2022. The technical and regulatory considerations for the gas centrifuge enrichment process have been addressed in the safety assessment of that application and are not considered further in this report (NRC, 2021).
DOE and its national laboratories are also exploring various options for the production of HALEU fuel feed material, including two chemical processes (Electrochemical Processing,
22 Hybrid Zirconium Extraction Process). Both methods involve the recycling of spent nuclear fuel from DOE research reactors to recover highly enriched uranium (greater than 20 percent) that can then be down blended to make HALEU fuel feed material. A follow-on assessment may evaluate technical and regulatory considerations related to these DOE processes, if they were to be implemented by a commercial facility subject to NRC purview.
4.1.1.2 233U Production 233U is a fissile isotope of uranium that is produced either in a reactor, and subsequently isotopically purified, or with an accelerator by bombarding 232Th with neutrons. Approximately two tons of 233U was produced between 1954 and 1970 in various weapons material production reactors and commercial nuclear power plants. A majority of the U.S. inventory of 233U is stored at Oak Ridge National Laboratory (ORNL) in the form of oxides (e.g., UO2, U3O8) and Idaho National Laboratory in the form of fuel elements. The approximately 500 kg of 233U in storage at ORNL has been gradually down blended and mixed with a grout for transportation and disposal (Peretz, 1996).
4.1.1.3 UF4 Production All commercial 235U enrichment plants use uranium hexafluoride (UF6) as the feed material for reactor fuel productions, so that is likely the starting compound for producing both LEU and HALEU UF4 for molten salt reactors. Chemical methods used for conversion of UF6 to UF4 are available (IAEA, 1994; McFarlane et al., 2019), including direct conversion reactions as well as indirect conversion through the initial production of UO2 from UF6 (as is currently done for the production of light-water reactor fuel forms). Currently it is not clear which of these processes would be chosen for large-scale production of enriched UF4 from UF6 for near-term MSR technologies. The conversion of UF6 to UF4 has been previously demonstrated to produce metallic fuels, and potential alternative approaches for the production of UF4 from spent nuclear fuel have also been proposed.
4.1.1.3.1 Methods for direct conversion of UF6 to UF4 Two methods implemented on a commercial scale involve the conversion of UF6 to UF4 via carbon tetrachloride (CCl4) reduction or hydrogen (H2) reduction (McFarlane et al., 2019). Other processes have been tested on a small scale and are not discussed here. These methods involve reactants such as nitrogen oxides (NOx), hydrogen bromide (HBr), hydrogen chloride (HCl) or hydrogen iodide (HI).
The reduction of UF6 with CCl4 produces UF4 at 120 - 150°C with gaseous effluent byproducts of chlorine (Cl2), freons (CClxF(4-x)), and excess CCl4 (McFarlane et al., 2019). All these byproducts are toxic and corrosive, and the occupational permissible exposure limits (PELs) per the Occupational Safety and Health Administration (OSHA) are provided in Table 4-2. The reaction is exothermic and a resultant pressure buildup must be managed (McFarlane et al.,
2019).
6() + 24() 4() + 2() + 23()
23 The hydrogen reduction process involves the reaction of UF6 with H2 gas to form UF4 and hydrofluoric acid (HF) at elevated temperatures (1,200-1,700°C) in a monel reactor (IAEA, 1994; Aleksandrov et al., 2016; McFarlane et al., 2019). The reaction is exothermic, and the HF gas product is toxic and highly corrosive. The generation of HF gas must be managed per OSHA PELs (Table 4-2) and should be evaluated for compatibility with the materials used in the process.
6() + 2() 4() + 2()
IAEA (1994) discusses process and equipment considerations for the hydrogen reduction process. UF6 cylinders are heated in autoclaves that provide a controlled vaporized UF6 feed to a surge vessel ahead of the reduction reactors. Nitrogen gas (N2) is used to purge the cylinder discharge lines and reactor feed lines. Hydrogen gas is fed to each cylindrical reactor and mixed with UF6 in a conical section designed to minimize slag buildup on the reactor walls. The reactor heating profile (480 °C [896 °F] (bottom) - 650 °C [1202 °F] (top)) is maintained by clam-shell zone electrical heaters. Compressed air is supplied to each zone for rapid cool-down or shutdown of the reactors.
The UF4 and gaseous reaction products pass from the bottom of the reactor to a screw-type cooling conveyor and later to a pulverizer. The process must be controlled to avoid the production and accumulation of UFX, where 4 < x <5, which can deposit on the process equipment. Removal of these products may require mechanical removal, which would generate radioactive particulates and aerosols.
An off-gas and particulate management system is necessary to manage or allow reuse of process products, including HF, N2, H2, residual UF6, and fine particulates of UF4. UF4 particulates are captured in sintered metal filters and residual UF6 is captured in activated charcoal traps. The off-gas stream then runs through chemical traps for HF, N2 and H2, and is passed through a circuit consisting of a pre-cooler, a partial condenser, and finally a total condenser to remove the HF. The HF is collected in storage tanks and may be recycled to a UF6 conversion plant. Recovered H2 and N2 is discharged to atmosphere via a mist eliminator and a neutralization scrubber.
4.1.1.3.2 Methods for indirect conversion of UF6 to UF4 (UO2 intermediate)
Various approaches could be used for the indirect production of UF4 from UF6 via the intermediate UO2. Five different methods of converting UF6 to UO2 are discussed in detail in IAEA (1994). These UF6 conversion approaches are as follows:
- 1) Precipitation of ammonium uranyl carbonate ((NH4)4UO2(CO3)3, AUC) where UF6 is fed into a stirred aqueous system with gaseous CO2 and NH3. The AUC precipitate is filtered out and later decomposed in a fluidized-bed reactor to produce UO2.
6 + 52+ 103 + 32 (4)4 2 (3)3 + 64
24
- 2) Production of the intermediate ammonium diuranate ((NH4)2U2O7, ADU), where ADU is produced per the following reactions. The ADU precipitate is subsequently filtered and washed with hot water and then converted to UO2 using hydrogen or cracked ammonia.
6 + 22 22 + 4 222 + 64 (4)227 + 44+ 32 In a modified ADU conversion process, the first step is replaced by hydrolysis of UF6 in aluminum nitrate solution (see below) and followed by total phenolic solvent extraction.
6 + 2(3)3 + 222(3)2 + 23 + 43
- 3) In the integrated dry route process method, UF6 is converted directly to a ceramic grade UO2 powder by reaction of UF6 vapor with steam and hydrogen in the following overall reaction:
6 + 22+ 2 2 + 6
- 4) In this method developed by the General Electric Company, vaporized UF6 is fed into a flame reactor to produce U3O8 and the U3O8 is reduced in a kiln to produce UO2 in the summarized reaction below.
6 + 32 + 2 2 + 6
- 5) In the final method, known as the fluidized-bed process, UF6 is converted to UO2 by steam and hydrogen via uranyl fluoride (UO2F2) at multiple fluidized-bed reactors. Dry scrubbers use calcium hydroxide to recover HF from the effluent gas in the form of calcium fluoride. The intermediate stage and overall reactions are shown below.
6 + 22 22 + 4 22 + 2 2 + 2 Once enriched UO2 powder is produced using any of the above methods (or any not listed), the UO2 powder can be reacted with pure HF gas at elevated temperatures to produce enriched UF4 per the following reaction (Souek et al., 2017):
2 + 4 4 + 22 Care must be exercised in this final conversion step to ensure an inert environment to avoid any undesired reactions with moisture and oxygen from the ambient atmosphere. Additionally, the uranium oxide powder should be prepared by reducing any U(VI) to U(IV) and facilitating the highest possible surface area to enhance the kinetics of the fluorination reaction.
25 4.1.1.4 UF4 Transportation A preliminary review of transportation packages on the RAMPAC (Radioactive Materials Packages) database was performed to identify transportation packages approved by NRC, DOE, and U.S. Department of Transportation (DOT) for shipment of UF4.
The NRC has not yet approved transportation packages for transport of UF4 under domestic use, i.e., no specific approvals per the regulatory requirements of 10 CFR Part 71. However, the NRC has approved two transportation packages for import and export from outside the United States under revalidations of approvals by foreign competent authorities. These revalidations are conducted under a Memorandum of Understanding with DOT, the Competent Authority for import and export transport of radioactive materials for the United States. The associated safety reviews are conducted per IAEA safety requirements, which are mostly consistent with 10 CFR Part 71. A brief summary of these revalidations follows:
DAHER Nuclear Technologies GmbH, Transportation Package Model No. BU-D On May 3, 2019, the DOT issued a certificate of revalidation for German Certificate of Approval No. D/4305/AF-96, Revision 10 for Model No. BU-D (DOT, 2019a). The certificate of revalidation expires on January 31, 2024. The safety review was conducted per IAEA Safety Standards Regulations for the Safe Transport of Radioactive Material, Specific Safety Requirements No. SSR-6 (IAEA, 2012). The transportation package allows for transport of depleted, natural and/or enriched UF4 with a maximum enrichment (235U) of 5 percent. The maximum allowed mass content of 235U in the depleted, natural, and enriched uranium is 0.8 kg.
TN International, Transportation Package Model No. TN-BGC1 On June 13, 2019, the DOT issued a certificate of revalidation for French Certificate of Competent Authority F/313/B(U)F-96, Revision 20 for Model No. TN-BGC-1 (DOT, 2019b). The certificate of revalidation expires on March 1, 2024. The safety review was conducted per IAEA Safety Standards Regulations for the Safe Transport of Radioactive Material, Specific Safety Requirements No. SSR-6 (IAEA, 2012). The transportation package allows for transport of UF4 in multiple configurations with a maximum enrichment (235U) of 30 percent. The maximum allowed mass content of 235U is dependent on the containment diameter, the presence of hydrogen-bearing materials with higher hydrogen quantity than water, and the number of packages in an array.
Consistent with 49 CFR 173.7(d), the DOT may also grant authorization to the DOE for the use of transportation packages for radioactive materials made by or under the direction of DOE if evaluated against equivalent regulations to 10 CFR Part 71. Under this authorization, DOEs Packaging Certification Program (PCP) has approved one transportation package for UF4:
DOE, National Nuclear Security Administration, Y-12 National Security Complex, Transportation Package Model No. ES-3100 On April 22, 2021, DOEs PCP issued Revision 18 of Certificate of Compliance No. 9315 for the Model No. ES-3100 (DOE, 2021). The transportation package allows for transport of UF4 with a maximum enrichment (235U) of 100 percent. The maximum allowed mass
26 content of 235U is approximately 18 kg depending on the Criticality Safety Index of the package.
The above approvals would provide limited flexibilities for the transportation of UF4 to a reactor site. The NRC revalidations of approvals by foreign competent authorities would require initiation of transport from a foreign facility. Further, approvals under the DOE PCP would require initiation of transport from a DOE facility and receipt at a reactor locality also located in a DOE facility. Therefore, the above approvals would not allow for the transportation of UF4 from a domestic commercial facility (licensed under 10 CFR Part 70) to a commercial reactor site. New NRC-approvals are likely necessary to support this scenario.
It is also important to note that the transport of UF4 enriched with 233U will likely require approval of a Type B transportation package due to the limited quantity acceptable for shipment in a Type A transportation package per Table A-1 in Appendix A of 10 CFR 71. Therefore, transportation packages for UF4 enriched with 233U will likely be subject to more rigorous test requirements than for UF4 enriched with 235U.
The safe transportation of UF4 is not expected to involve new hazards relative to the transportation of UF6, which is regularly performed in standardized cylinders (ANSI, 2019). UF4 is not expected to undergo thermal decomposition during the thermal test for hypothetical accident conditions. UF4 will exothermically react with water, albeit slower than UF6, for the production of HF and uranyl fluoride (UO2F2). The primary considerations for the safety hazards will involve ensuring compatibility with materials used for primary containment of UF4 in a transportation package and maintaining an adequate subcriticality margin for hypothetical accident conditions. Additionally, loading operations will require ensuring that an inert atmosphere is maintained in the primary containment and transport operations that preclude the ingress and interaction of water and air with the UF4 contents.
4.1.2 Uranium Trichloride (UCl3) 4.1.2.1 Chlorine Isotopic Enrichment Molten salt reactor vendors planning to use chlorine-based fuel materials (e.g., UCl3) would need to consider purifying the chlorine to increase the 37Cl-to-35Cl ratio to decrease the production of 36Cl (long half-life beta emitter) and 35S that increases corrosion. 37Cl has a natural abundance of 24.23 percent compared to 75.77 percent for 35Cl. Although no commercial scale chlorine purification method has been established, several laboratory-scale methods have been demonstrated that could be scaled. Among these methods are gas-phase isotopic separation, liquid-phase thermal diffusion, room-temperature anion exchange chromatography, and NaCl crystallization (McFarlane et al., 2019). These purification processes are expected to take place in a commercial facility, outside the purview of the NRC.
4.1.2.2 UCl3 Production Uranium forms four chlorides (i.e., UCl6, UCl5, UCl4, UCl3) depending on its oxidation state. It is feasible that UCl3 could be employed in a molten salt fast reactor. UCl3 has been most
27 commonly produced from the precursor UCl4, which is the most stable of the uranium chlorides.
UCl4 can be produced by chlorinating uranium oxides or fluorides, such as UF6 (most common since this is the general form after enrichment) or UF4. Effective chlorinating agents include CCl4, hexachloropropene (C3Cl6), Cl2, phosgene (COCl2), or mixtures of carbon monoxide (CO) with Cl2. Each of these chlorinating agents are hazardous materials of varying levels of toxicity that must be handled and stored under appropriate controls. Once UCl4 is formed, it readily reduces to UCl3 when reacted with hydrogen (H2) at high temperature (550°C). McFarlane et al.
(2019) provide additional details on the production methods for the precursor UCl4.
UCl3 has also been prepared in kilogram quantity by a two-step process involving the conversion of pure uranium metal (cleaned in nitric acid) with H2 to produce uranium hydride (UH3) at 250 °C, followed by reaction with HCl gas (Johnson et al., 1944). Alternatively, UCl3 can be formed directly through reaction of pure uranium metal with a metal chloride such as CdCl2 (Yoo et al., 2018), BiCl3 (Lambert et al., 2018), or PbCl3 (Bradley, 1957)) as shown by the below representative reactions. These methods are much less likely to be used since enriched uranium is generally in the form of uranium oxides or fluorides.
2+ 32 23 + 3
+ 3 3 +
+ 3 3 +
4.1.2.3 UCl3 Transportation A preliminary review of transportation packages on the RAMPAC site certified by the NRC, DOE, and DOT did not identify transportation packages approved for shipment of UCl3.
The safe transportation of UCl3 will require controls for loading and transport operations to maintain the contents in the same oxidation state and preclude ingress and interaction of water or air with the contents. UCl3 has a melting point of 842 +/- 5 °C and decomposes at temperatures above 850 °C to produce UCl4. Since transportation of UCl3 is likely to occur in Type A fissile packages, these temperatures are unlikely to occur during normal conditions of transport. UCl3 will react with water to produce hydrogen, uranium dioxide, and HCl. The material has also been reported to exothermically react with oxygen at 150-200 °C to produce uranyl chloride (UO2Cl2), Cl2 and UO2 (Johnson et al., 1944). The primary considerations for safety hazards will involve ensuring compatibility with materials used for primary containment of UCl3 in a transportation package and implementing loading operations that ensure an inert atmosphere is maintained for the UCl3 contents.
4.1.3 Thorium Fluoride (ThF4) 4.1.3.1 ThF4 Production 232Th has been proposed for use as a fertile material for Flibe Energys Lithium Fluoride Thorium Reactor (LTFR), in which 232Th would transmute to 233U to sustain the fission reaction. 232Th is a
28 natural-occurring weakly radioactive isotope with a natural isotopic abundance of 99.98 percent 232Th and a half-life of approximately 14 billion years. Thorium is estimated to be over three times as abundant as uranium in the earths crust and is currently primarily recovered from the mineral monazite (a rare-earth phosphate mineral) as a byproduct of processing heavy mineral sand deposits for titanium-, zirconium-, or tin-bearing minerals (IAEA, 2005). It is unclear whether the LTFR blanket fuel will require higher purity of 232Th relative to its natural isotopic abundance.
Significant experience exists on the production of thorium oxide or thoria (ThO2) used in nuclear fuels for operating water-cooled reactors (NEA & IAEA, 2016; AEC, 1969; IAEA, 2005).
However, ThO2 is highly insoluble in lithium-beryllium fluoride mixtures and therefore not suitable for use in MSRs. Instead, ThF4 has been proposed for use as the fertile blanket fuel in the Flibe Energy LFTR design (EPRI, 2015).
ThF4 is currently produced and used in optical coatings for antireflective, bandpass and dichroic filters, and was previously used in carbon arc lamps. ThF4 can be synthesized using various techniques involving the reaction of ThO2 with hydrogen fluoride gas, aqueous hydrofluoric acid, ammonium fluoride (NH4F), or ammonium bifluoride (NH4HF2) (Bahri et al., 2019). The most convenient of these methods is the heating of ThO2 in excess anhydrous hydrogen fluoride gas at temperatures of 400 - 550 °C and near atmospheric pressure, per the following chemical reaction (Souek et al., 2017; Briggs et al., 1971).
2 () + 4 () 4 () + 22 ()
This method requires the elimination of moisture, which may result in the formation of thorium oxyhydrates or oxyfluorides.
Another aqueous-based method involves the precipitation of ThF4 from the reaction of thorium nitrate (Th(NO)3) and hydrofluoric acid in a semi-continuous process in polymer-based equipment, per the following chemical reaction (Briggs et al., 1971).
()3 () + 4 () 4
- 2 () + 43 ()
After recovery of the hydrated ThF4 by filtration, the material is dried at 350°F in air to a moisture content of 1 or 2 percent. ThF4 is then thoroughly dehydrated in batch tray retorts of Inconel construction by heating in the range 800° to 1000°F under very small flows of nitrogen and anhydrous HF to prevent oxidation or pyrohydrolysis. The dehydration process is known to be limited by the formation of thorium hydroxide (Th(OH)4) or thorium oxyfluoride (ThOF2) (Bahri et al., 2019).
Fluorination of ThO2 with NH4F and NH4HF2 has also been studied. The reaction with NH4F yields a tetravalent fluoro-complex NH4ThF6, which decomposes to ThF4 at temperatures above 350 °C (Bahri et al., 2019). The reaction with NH4HF2 yields, in part, (NH4)3ThF7, which decomposes to ThF4 at temperatures above 450 °C. Both methods require high ratios of the fluorinating agents, i.e. eight-fold excess or higher. While these fluorinating agents are easier to
29 handle than HF, the need for high amounts of fluorinating agents may hinder deployment of these methods in large-scale.
Direct conversion to ThF4 by the reaction of thorium metal with F2 gas, per the following equation, is also possible. A follow-on assessment to this report may include a thorough review of the viability and process conditions for this process.
() + 22 () 4 ()
It is important to note that the use of ThF4 in an MSR design was previously explored but not implemented in an operating reactor. In the late 1960s, the Molten Salt Breeder Reactor (MSBR) program, a follow-on activity to the Molten Salt Reactor Experiment at Oak Ridge National Laboratory (ORNL), pursued the design of a thermal-spectrum breeder MSR with online continuous monitoring, which was to operate on a 233U-232Th fuel cycle (AEC, 1972). The system was designed to operate with a fuel-salt mixture of ThF4 (12 mole percent) and UF4 (0.3 mole percent) in 7LiF (72 mole percent) and BeF2 (16 mole percent). The reactor was never constructed and operated. A preliminary review of the literature has not provided details on the methods that were proposed for the synthesis of ThF4 for the MSBR program. The fluorination of thorium was also studied under the Manhattan Project (Sorenson, 2014) but information on those activities is not readily available.
It is also important to note that the Peoples Republic of China will begin operations in the near-term of a liquid fluoride thorium reactor (Mallapaty, 2021). The reactor will produce two megawatts of thermal energy and will be operated by the Shanghai Institute of Applied Physics at Wuwei, on the outskirts of the Gobi Desert (Song, 2012). A preliminary review of open literature has not identified details related to the production or transportation approaches used for supplying ThF4 to that reactor.
4.1.3.2 ThF4 Transportation A preliminary review of transportation packages on the RAMPAC site certified by the DOE, NRC, and DOT did not identify transportation packages approved for shipment of ThF4.
Transportation is likely to occur in a Type A package.
The safe transportation of ThF4 is expected to involve similar hazards to the transportation of UF4. ThF4 is not expected to undergo thermal decomposition during temperatures corresponding to normal conditions of transport for the expected shipment in Type A packages.
ThF4 is reported to be significantly more stable than ThO2 upon comparison of their relative heats of formation (Hf) (Baes, 1974). Therefore, reaction of ThF4 in the presence of oxygen and moisture (e.g., production of ThOF2) during transport conditions is expected to be limited.
The primary considerations for safety hazards will involve ensuring compatibility with materials used for primary containment of ThF4 in a transportation package and implementing loading operations that ensure an inert atmosphere is maintained to maintain ThF4 purity (IBI, 2014).
30 4.1.4 Tristructural Isotropic (TRISO) Solid Fuel 4.1.4.1 TRISO Production TRISO-coated fuel particles and pebbles have been produced and used in high temperature gas reactors (HTGRs) operating under pressurized helium with coolant outlet temperatures in the range of 700 to 950°C (Demkowicz et al., 2019; IAEA, 2010; Richards, 2002). Historically, a broad range of TRISO fuel particles have been fabricated and tested around the world, including compositions based on uranium oxide (UO2), uranium-thorium oxide ((U,Th)O2), uranium dicarbide (UC2), uranium-thorium carbide ((U,Th)C), plutonium oxide (PuO2) and a heterogeneous mixture of uranium oxide and uranium carbide (UCO). TRISO fuel pebbles are being considered for the FHR under development by Kairos Power.
TRISO-coated fuel pebbles consist of fuel particles with fissile or fertile material (UCO being proposed for the KP-FHR) with diameters in the range of 350-600m (Figure 4-1) (Demkowicz et al., 2019). Sol-gel synthesis processes are the most common for the fabrication of the fuel kernels. In this method, sol-gel spheres are made using internal or external gelation methods.
For example, uranium is dissolved in nitric acid (HNO3) and ammonia (NH3) is used to precipitate a metal oxide from the sol (e.g., uranium trioxide (UO3)) and form a gel sphere as the droplets pass through a heated liquid medium (Demkowicz et al., 2019). Alternatively, uranyl nitrate (UO2(NO3)2) can be reacted in a high-pH (basic) solution of hexamethylenetetramine (C6H12N4) and urea (CH4N2O) to produce uranyl hydroxide (UO(OH)2) gel spheres (EPRI, 2020).
The gel spheres are washed, dried, and heated in appropriate atmospheres to drive off byproducts of the sol-gel conversion and form a final sintered UO2 kernel. Carbon can be dispersed in the sol to produce uranium carbide within the kernel.
Figure 4-1 UCO TRISO Particle (left) (Demkowicz et al., 2019) and Fuel Pebble (right)
(Mitchell et al., 2020).
Each UO2 or UCO kernel is generally coated by four different layers applied using fluidized-bed chemical vapor deposition (Figure 3-3). In this process, kernels are fluidized with argon and reactant gases that decompose and deposit on the kernels. An initial porous (approximately 50 percent of theoretical density) carbon buffer layer on the kernel is produced using acetylene (C2H2). This layer provides void space for fission gases released from the kernel and accommodates fission recoils. A subsequent layer of dense, highly isotropic inner pyrocarbon
31 (IPyC) layer is then deposited by mixing propylene (C3H6) with acetylene and argon. This layer contributes to the retention of fission gases in the particle, as well as acts as a seal layer to protect the kernel from the HCl byproduct resulting from subsequent silicon carbide (SiC) layer deposition. A third SiC layer is then applied by mixing methyltrichlorosilane (CH3SiCl3) and hydrogen with or without the presence of argon. This layer provides the main structural strength of the particle and is the primary barrier to the release of non-gaseous fission products not sufficiently retained by the IPyC layer or within the kernel itself. An additional outer pyrocarbon (OPyC) layer is then deposited using a similar approach to the IPyC layer. This final layer protects the SiC layer during handling, acts as a surface for bonding to the graphitic fuel matrix and provides an additional barrier to fission product release (especially fission gases). The finished coated particle is a small (1 mm outside diameter) carbon and ceramic sphere that is stable to temperatures well beyond 1600°C (Mitchell, et al., 2020).
TRISO particles are then consolidated in a matrix on around a low-density core of the fuel pebble (Figure 3-2 and Figure 4-1). The matrix is achieved by pressurizing graphite flakes and a thermoplastic or thermosetting resin with the fuel particles and heating to carbonize the resin.
TRISO particles are overcoated with the graphite/resin blend prior to pressing in order to prevent particle-to-particle contact during the molding process, which may damage the particles.
In the 1960s and 1970s, a large-scale coated particle fuel fabrication facility was established by General Atomics to support the production of prismatic fuel elements containing TRISO-coated (Th,U)C2 fissile fuel particles and TRISO-coated ThC2 fertile fuel particles (EPRI, 2020). The facility has since been decommissioned and dismantled, and therefore no facility is currently licensed for the fabrication of TRISO fuels in the United States. In 2002, the U.S. DOE established the Advanced Gas Reactor Fuel Development and Qualification Program, which one of its objectives is to establish domestic TRISO particle fuel manufacturing capabilities in support of prismatic and pebble-bed HTGR fuel designs (Mitchell, et al., 2020). Under this program, TRISO particles with UCO kernels enriched to 19.7 percent 235U have been fabricated.
The target quality level for TRISO-coated particle fuel is based on the quality level achieved for a fuel particle design (EUO 2358-2365) in a German program during the late 1980s. A follow-on assessment may include an evaluation of the chemical processes and hazards for the fabrication of TRISO-coated pebbles under this ongoing DOE program.
4.1.4.2 TRISO Transportation A review of operating experience and potential challenges associated with the transportation of TRISO fuels has been documented elsewhere and is not discussed further in this report. (Hall et al., 2019a; Hall et al., 2019b).
4.1.5 Non-Radioactive Salt Carriers and Coolants The following discussions provides a description and technical considerations related to the hazards for non-radioactive salts planned for use in the five MSR designs.
32 4.1.5.1 FLiBe Salts The most common salt being considered for the fuel carrier salt in MSR designs is a salt referred to as FLiBe due to its composition of fluoride, lithium, and beryllium. FLiBe salts are compounds with a stoichiometry of Li2BeF4 and composition of lithium fluoride (LiF) and beryllium fluoride (BeF2). FLiBe salts are highly toxic and must be handled in closed systems with personal protective equipment to minimize the chance of exposure. FLiBe salts of a nominal 2 LiF: 1 BeF2 mole ratio were first used as the intermediate coolant in the MSRE at ORNL. However, a preliminary review of publicly available information on the MSRE has not identified the specific processes used for FLiBe production. Table 4-1 provides the physical properties of the FLiBe salts used in the MSRE program.
Table 4-1 Physical Properties of MSRE Coolant/Flush FLiBe Salts (Cantor et al., 1968)
Composition LiF:BeF2 (2:1 mole ratio)
Liquidus Temperature (°C) [Peritectic]
458 +/- 1 Solidus Temperature (°C) 360 +/- 3 Density of Liquid (g/cm3) 2.214 - 4.2x10-4 *T +/- 2 percent Thermal Conductivity (W/m/°C) 0.010 +/- 0.001 Solid Heat Capacity, CP (cal/g/°C) 0.317 + 3.61x10-4 *T +/- 3 percent Liquid Heat Capacity, CP (cal/g/°C) 0.57 +/- 3 percent Heat of Fusion, HF (cal/g) 107 +/- 3 percent Viscosity, (cP) 0.116
- exp(3755/T(°K)) +/- 15 percent Volumetric Coefficient of Thermal Expansion (ppm/°C) 2.1 +/- 20 percent Vapor Pressure, Pv (Torr) log Pv (Torr) = 9.04 - (10500/T(°K)) +/- 10 percent Electrical Conductivity (ohm/cm) 1.54 + 6.0x10-3 (T - 500) +/- 10 percent Materion Corporation provided FLiBe salts for use in the MSRE (Vidal, 2013). A preliminary review of information available on the LFTR has not identified the specific composition of FLiBe salts to be used in that reactor design.
The production of FLiBe salts will generally require isotopic enrichment with 7Li to be usable as an MSR carrier and coolant salt, due to the high neutron absorption cross section of 6Li. It is estimated that similar purities to the MSRE flush and coolant salts will be required, which had a 7Li abundance ranging from 99.991 to 99.994 percent. One method for 7Li enrichment method that was used in the 1950 to 1960s was a lithium hydroxide-mercury amalgam column exchange-based (Colex) separation process; however, industrial-scale mercury usage presents large environmental contamination and health risks (McFarlane et al., 2019). Other lithium separation methods include ion exchange, chemical exchange, electrolysis, electro-migration, and selective capture of lithium isotopes with a crown ether (Martoyan et al., 2016).
33 FLiBe salts are corrosive and contain highly hazardous beryllium, which may impact handling and processing operations at the plant. Management of FLiBe salts requires protective clothing and respirators, or the use of glove boxes, as well as specialized training, policies, and procedures.
4.1.5.2 Other Non-Radioactive Salts A unique aspect of MSR designs is that they feature a broad spectrum of different coolant compositions. In addition to the most common salt discussed above, FLiBe, near-term MSR technologies use a variety of commercial non-radioactive salts, including fluorides, chlorides, and nitrate-based solar salts. Many of these industrial salts are strong oxidizers and highly sensitive to moisture. Due to their hygroscopic properties, handling and storage methods will need to ensure an inert atmosphere is maintained during fuel-salt mixing and transportation operations.
Another salt considered for use in MSRs is referred to as FLiNaK and composed of fluoride (F),
lithium (Li), sodium (Na), and potassium (K). FLiNaK is a ternary eutectic alkaline metal fluoride salt mixture of lithium fluoride (46.5 mole percent), sodium fluoride (11.5 mole percent), and potassium fluoride (42 mole percent). Technical considerations related to FLiNaK are not provided in this report since it is not used in near-term MSR technologies.
4.2 Regulatory Approaches and Safety Considerations Front-end operations for near-term MSR fuel technologies will involve the management of materials without regulatory precedent, which will require the safety review of different hazards relative to current solid-based light-water reactor fuels. Continued engagement to understand industrys plans for these activities and the regulatory approaches to be pursued will assist in assessing the risk significance of these hazards.
A review of available information submitted to the NRC and communicated through public workshops (e.g., annual MSR workshops hosted by ORNL) has not provided certainty about the approaches to be followed by each MSR vendor for front-end operations (ORNL, 2021).
Different safety-related regulatory frameworks may be impacted depending on the chosen approach or necessary activity, including:
10 CFR Part 40, Domestic Licensing of Source Material 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities 10 CFR Part 52, Licenses, Certifications, and Approvals of Nuclear Power Plants 10 CFR Part 53, Risk Informed, Technology-Inclusive Regulatory Framework for Advanced Reactors 10 CFR Part 70, Domestic Licensing of Special Nuclear Material 10 CFR Part 71, Packaging and Transportation of Radioactive Material
34 In addition, compliance with other regulatory frameworks related to environmental and physical protection, and materials control and accounting will need to be evaluated, including:
10 CFR Part 51, Environmental Protection Regulations for Domestic Licensing and Regulatory Functions 10 CFR Part 73, Physical Protection of Plants and Materials 10 CFR Part 74, Material Control and Accounting of Special Nuclear Material The applicability of these regulatory frameworks will likely vary between molten salt-fueled and solid-fueled (molten salt-cooled) MSR designs as well as the need for fertile material sourcing to support reactor operation. Figure 4-2 provides a schematic of a preliminary assessment of potential regulatory approaches to be pursued.
35 Figure 4-2 Applicability of Regulatory Frameworks to Front-End Activities for Molten Salt Reactors.
36 The need for new facilities for uranium conversion is not anticipated since this process step is not impacted by reactor-specific technologies. It is likely that the currently licensed uranium conversion facility operated by Honeywell near Metropolis, Illinois, which is licensed under 10 CFR Part 40, will be able to support UF6 needs for MSR fuels. Approaches for the sourcing and mining operations for natural thorium to produce ThF4 in support of the LFTR has not been discussed by Flibe Energy. Conventional mining of thorium ores is expected to be regulated by the Office of Surface Mining, the Department of the Interior, and the individual states where the mines are located. The activities may also be regulated by NRC under the regulatory framework for 10 CFR Part 40 if the ore is processed or chemically altered or exceeds thorium concentration thresholds, as defined in 10 CFR 40.13.
Operations for the enrichment and production of LEU and HALEU fuel materials (e.g., UF6, UF4, UCl3, ThF4, or TRISO enriched to less than 20 percent 235U) are expected to be conducted under the regulatory framework for 10 CFR Part 70 and subject to safety reviews per NUREG-1520, Revision 2 (NRC, 2015). The Integrated Safety Analyses (ISA) for a production facility managing HALEU fuel materials will need to demonstrate compliance with the performance requirements of 10 CFR 70.61. NUREG-1520, Revision 2, defines a graded approach for acceptable level of risk, which will likely require different means and level of effort to meet the criteria for likelihood of events in 10 CFR 70.61.
The production of halide-based fuel materials being considered for MSRs will involve highly toxic, corrosive, and reactive compounds, which will need to be evaluated in the ISA. Consistent with the safety review guidance in NUREG-1520, Revision 2, the ISA should provide a systematic evaluation of the safety hazards credible accident sequences, items relied on for safety, and management measures that satisfy the performance requirements of 10 CFR 70.61.
Further, the ISA should include quantitative standards for acute chemical exposures per the requirement in 10 CFR 70.65(b). The NRC has developed additional guidance on chemical safety practices acceptable for compliance with the regulations, as provided in NUREG-1601.
Table 4-2 provides permissible exposure limits (PELs) defined by the Occupational Safety and Health Administration for the various potential chemicals to be used in the production of MSR fuels.
Although not denoted in Figure 4-2, the licensing of enrichment and fuel production facilities will also need to demonstrate compliance with the requirements in 10 CFR Parts 74 and Part 73.
Consistent with NUREG-1520, Revision 2, an application for a 10 CFR Part 70 license will need to provide an adequate material control and accounting (MC&A) program to protect against the loss, theft, or diversion of special nuclear material (SNM) to be possessed, stored, and utilized at the facility. The review will assess compliance with the regulatory requirements in 10 CFR Part 74, which defines different category facilities to distinguish possession of different types and quantities of SNM (10 CFR 74.4). The NRC has previously licensed Category III facilities that possess SNM of low strategic significance facilities, which include those facilities used for LEU enrichment and fuel fabrication. However, the higher enrichment needs for MSR fuels will require licensing of Category II facilities that are authorized to possess SNM of moderate strategic significance. These facilities would manage HALEU fuel materials enriched with 10 percent but less than 20 percent 235U or managing between 0.5 to 2.0 kilograms of 233U.
37 NUREG-1520, Revision 2, provides high-level guidance for the necessary commitments for an MC&A program of Category II facilities. The NRC is developing additional guidance to support applicants in their development of MC&A programs. In addition, consistent with NUREG-1520, Revision 2, Category II facilities will need to establish and maintain a physical protection system consistent with the requirements in 10 CFR 73.67.
Different approaches may be implemented for the transportation of fuel-salt mixtures to MSR sites. The most likely approach assumed in Table 4-2 involves the independent transportation of fissile/fertile fuel material and the non-radioactive commercial salts to the reactor site facility, followed by on-site preparation of the initial reactor loading fuel-salt mixture. This approach would require NRC approval of transportation packages for individual fuel materials (233UF4, 235UF4, 235UCl3 ThF4, TRISO) under 10 CFR Part 71. If this approach is implemented, fuel-salt mixing would be conducted under the reactor operating license and subject to safety reviews under 10 CFR Parts 50, 52, or 53.
An alternate approach would involve the preparation of fuel-salt mixtures for reactor loading and refueling at a separate facility licensed under 10 CFR Part 70. This approach would reduce chemical processing risks at the reactor site, particularly for the preparation of the initial core loading which will require significantly more material than refueling quantities. A separate fuel-salt preparation facility may provide efficiencies when supplying multiple reactor sites. This approach would add complexities related to the performance of fuel-salt mixtures during transport.
NUREG-2216 provides guidance for the safety review of transportation packages, which is broadly applicable to MSR fuels and fuel-salt mixtures. The performance-based regulations in 10 CFR Part 71 include assessing the effects of corrosion, chemical reactions, and radiation on the contents (10 CFR 71.43(d)) and demonstrating that the package satisfies the standards specified in subparts E and F (10 CFR 71.35(a)). The guidance also reinforces the need to assess the environment inside the packaging to which the contents are exposed, including requirements for dryness or use of inert gases, which will likely be necessary for transport of MSR fuels and fuel-salt mixtures. The primary areas of the safety review for transportation packages that are expected to be impacted include criticality, radiation dose, containment, and materials.
38 Table 4-2 Safety Considerations for Production and Transportation of Molten Salt Reactor Fuels Activity Production Method Hazardous Material Safety Considerations OSHA Permissible Exposure Limit TWA*
(OSHA, 2021)
Facility or Transportation Package Design/Performance Considerations All uranium (U)-based fuel production methods Uranium (different forms)
Toxic; alpha emitter 25 ppb of U 10 CFR Part 70, NUREG-1520 Integrated Safety Analysis:
Quantitative Standards for Chemical Consequences Uranium tetrafluoride (UF4) production Direct and indirect conversion Hydrogen fluoride (HF)
Toxic; highly corrosive; reacts with metals to produce H2 3 ppm Direct conversion -
hydrogen reduction Hydrogen (H2)
Flammable N/A Direct conversion -
CCl4 reduction Carbon tetrachloride (CCl4)
Toxic; possible carcinogen 10 ppm Chlorine (Cl2)
Toxic; corrosive 1 ppm (ceiling)
Freons (CClxF(4-x))
May cause frostbite; may displace oxygen 1000 ppm Indirect conversion -
AUC & ADU Ammonia (NH3)
Toxic; corrosive; may form explosive mixture with air at high temperatures 50 ppm Uranium trichloride (UCl3) production Chlorination Phosgene (COCl2)
Toxic; corrosive 0.1 ppm Hexachloropropene (C3Cl6)
Toxic Not available Carbon m(CO):
Toxic 50 ppm Others - CCl4, Cl2 See above See above Thorium fluoride (ThF4) production Fluorination HF Toxic; extremely corrosive; reacts with metals to produce H2 3 ppm Fluorine (F2)
Toxic; strong oxidizer/
corrosive 0.1 ppm Ammonium fluoride (NH4F)
Toxic; corrosive; reacts with moisture to form HF 1.65 ppm Ammonium bifluoride (NH4HF2)
Toxic; corrosive; reacts with moisture to form HF 1 ppm TRISO fuel production Sol-gel synthesis Nitric Acid (HNO3)
Toxic; corrosive 2 ppm Ammonia (NH3)
Toxic; corrosive; may form explosive mixture with air at high temperatures 50 ppm
39 Activity Production Method Hazardous Material Safety Considerations OSHA Permissible Exposure Limit TWA*
(OSHA, 2021)
Facility or Transportation Package Design/Performance Considerations TRISO fuel production Sol-gel synthesis Hexamethylenetetramine (C6H12N4)
Toxic; Combustible; Finely dispersed particles form explosive mixtures in air 174 ppb Urea (CH4N2O)
Toxic 6 ppm Chemical vapor deposition Acetylene (C2H2)
Extremely flammable Not available Propylene (C3H6)
Extremely flammable 500 ppm Methyltrichlorosilane (CH3SiCl3)
Flammable, toxic 5 ppm (ceiling)
Hydrochloric acid (HCl)
Toxic, Corrosive 5 ppm (ceiling)
Transportation of UF4, UCl3, and ThF4 Decomposition Byproduct: Cl2 Moisture control, thermal stability See above 10 CFR Part 71, NUREG-2216 Safety Analysis Report:
Criticality, Radiation Dose, Containment, Materials Moisture Reaction Byproduct:
HF, hydrochloric acid (HCl),
uranyl fluoride (UO2F2)
- 8-hour time weighted average (TWA), unless specified as ceiling. TWA is defined by the Occupational Safety and Health Administration (OSHA) as an employee's average airborne exposure in any 8-hour work shift of a 40-hour work week which shall not be exceeded.
40 5
SUMMARY
AND RECOMMENDATIONS The U.S. Nuclear Regulatory Commission (NRC) Office of Nuclear Material Safety and Safeguards (NMSS) has been monitoring both the U.S. Department of Energy (DOE) and industrys activities related to the development of advanced non-light-water reactor technologies, including those related to the potential licensing and certification of molten salt reactors (MSRs). To date, the NRC is aware of five vendors that have expressed interest or have been actively engaged in the development and potential near-term licensing and certification of MSR technologies, namely:
the Integral Molten Salt Reactor under development by Terrestrial Energy USA, the Fluoride Salt-Cooled High Temperature Reactor under development by Kairos
- Power, the Lithium Fluoride Thorium Reactor under development by Flibe Energy, the Molten Chloride Fast Reactor under development by TerraPower and Southern Nuclear, and the Molten Salt Research Reactor under development by Abilene Christian University.
This report provides a preliminary assessment of technical and regulatory considerations related to the management of unirradiated (fresh) fissile and fertile fuel materials (i.e., front-end operations) for near-term MSR technologies, including activities related to their enrichment, production, and transportation to a reactor site. These activities present distinct technical and regulatory challenges relative to uranium oxide based fuels used in current light-water reactor technologies and will involve licensing and certification actions without regulatory precedent.
Oak Ridge National Laboratory has historically led efforts to support the development of MSR technologies with two designs being built and operated, namely the Aircraft Reactor Experiment and the Molten Salt Reactor Experiment. The front-end activities for these prior operating reactors were conducted at the Y-12 National Security Complex with fuel-salt materials being provided by the Atomic Energy Commission and commercial sources. Production operations required specialized facilities for managing the highly corrosive and toxic materials and reducing potential impurities. Transportation activities were not conducted using commercial transportation packages. These operations provide perspective on the potential technical issues for front-end activities for future MSR technologies; however, the activities were not regulated under current NRC requirements.
A review of near-term MSR technologies based on publicly available information was conducted to identify preliminary fuel and salt compositions, as well as the current state of knowledge on plans for the enrichment, production, and transportation of unirradiated materials. The fuel-salt mixtures will be a combination of fissile and/or fertile materials of LEU or other isotopic (233U, 232Th) compositions with non-radioactive diluent or carrier salts. Fluoride salt-fueled reactors are expected to operate with uranium tetrafluoride (UF4) and thorium fluoride (ThF4), if fertile
41 material is used, dissolved in molten salts including FLiBe. It is feasible that chloride salt-fueled reactors will operate using uranium trichloride (UCl3) in salts including sodium chloride (NaCl),
calcium chloride (CaCl2) and magnesium chloride (MgCl2). Fluoride salt-cooled reactors are designed to operate with a solid pebble fuel based on tristructural isotropic (TRISO) particles. A review of potential methods and technical considerations for the enrichment and production of these materials is provided. Commercial vendors have provided very limited information on approaches for transportation to the reactor sites.
Different safety-related regulatory frameworks may be impacted depending on the chosen approach or necessary front-end activity, including 10 CFR Parts 40, 52, 53, 70, and 71. In addition, compliance with other regulatory frameworks related to environmental and physical protection, and materials control and accounting will need to be evaluated, including 10 CFR Parts 51, 73, and 74. The applicability of these regulatory frameworks will likely vary between molten salt-fueled and solid-fueled (molten salt-cooled) MSR designs as well as the need for fertile material sourcing to support reactor operation.
The need for new facilities for uranium conversion is not anticipated since this process step is not impacted by reactor-specific technologies. Operations for the enrichment and production of LEU and HALEU fuel materials (e.g., UF6, UF4, UCl3, ThF4, or TRISO enriched to less than 20 percent 235U) are expected to be conducted under the regulatory framework for 10 CFR Part 70 and subject to safety reviews per NUREG-1520, Revision 2 (NRC, 2015). The Integrated Safety Analyses (ISA) for a production facility managing HALEU fuel materials will need to demonstrate compliance with the performance requirements of 10 CFR 70.61. The production of halide-based fuels will involve highly toxic, corrosive, and reactive compounds, which will need to be evaluated in the ISA, including a systematic review of the safety hazards and credible accident sequences, items relied on for safety, and management measures that satisfy the performance requirements of 10 CFR 70.61.
Different approaches may be implemented for the transportation of fuel-salt mixtures to MSR sites. One approach would involve the independent transportation of fissile/fertile fuel material and the non-radioactive commercial salts to the reactor site facility, followed by on-site preparation of the initial reactor loading fuel-salt mixture. This approach would require NRC approval of transportation packages for individual fuel materials (233UF4, 235UF4, 235UCl3, ThF4, TRISO) under 10 CFR Part 71. If this approach is implemented, fuel-salt mixing would be conducted under the reactor operating license and subject to safety reviews under 10 CFR Parts 50, 52, or 53. Per this approach, the production and transportation of industrial non-radioactive salts would remain outside NRCs regulatory purview.
An alternate approach would involve the preparation of fuel-salt mixtures for reactor loading and refueling at a separate facility licensed under 10 CFR Part 70. This approach would reduce chemical processing risks at the reactor site, particularly for the preparation of the initial core loading which will require significantly more material than refueling quantities. A separate fuel-salt preparation facility may provide efficiencies when supplying multiple reactor sites. This approach would add complexities related to the performance of fuel-salt mixtures during transport.
42 The current safety review guidance for transportation packages is broadly applicable to MSR fuels and fuel-salt mixtures. The performance-based regulations in 10 CFR Part 71 include assessing the effects of corrosion, chemical reactions, and radiation on the contents (10 CFR 71.43(d)) and demonstrating that the package satisfies the standards specified in subparts E and F (10 CFR 71.35(a)). The guidance also reinforces the need to assess the environment inside the packaging to which the contents are exposed, including requirements for dryness or use of inert gases, which will likely be necessary for transport of MSR fuels and fuel-salt mixtures. The primary areas of the safety review for transportation packages that are expected to be impacted include criticality, radiation dose, containment, and materials.
The following recommendations are made for follow-on activities to support NMSS mission to license MSR fuel cycle operations, including front-end operations:
Expanded assessment of impacted regulatory frameworks. There is some degree of uncertainty related to the approaches used for mixing (outside facility or at-reactor) and transportation of fuel-salt mixtures. The preliminary assessment in this report assumes that mixing operations will occur at the reactor site; however, some developers (e.g.,
Abilene Christian University) expect that the pre-mixed fuel will be shipped directly to the reactor site. The first approach would involve regulatory oversight for mixing operations under 10 CFR Part 50, 52, or 53. The latter approach would involve regulatory oversight under 10 CFR Part 70. An extensive review of the applicable safety review guidance for these approaches was not conducted in this report.
Hazards associated with FLiBe and FLiNaK salts. The preliminary assessment in this report did not identify specific methods for the production of FLiBe and FLiNaK salts (although the latter are not proposed in near-term MSR technologies). Further, an evaluation of hazards associated with mixing operations of fuel materials with FLiBe and FLiNaK salts was not provided. A more extensive evaluation of these hazards and complexities for the design of transportation packages could be conducted in a follow-on assessement.
Production of HALEU feed materials for MSRs. DOE and its national laboratories are exploring various options for the production of HALEU fuel feed material, including two chemical processes (Electrochemical Processing, Hybrid Zirconium Extraction Process).
Both methods involve the recycling of spent nuclear fuel from DOE research reactors to recover highly enriched uranium (greater than 20 percent) that can then be down blended to make HALEU fuel feed material. A follow-on assessment could assess technical and regulatory considerations related to these DOE processes, if they were to be implemented by a commercial facility subject to NRC purview.
Fabrication of TRISO pebble fuels. In the 1960s and 1970s, a large-scale coated particle fuel fabrication facility was established by General Atomics to support the production of prismatic fuel elements containing TRISO-coated (Th,U)C2 fissile fuel particles and TRISO-coated ThC2 fertile fuel particles (EPRI, 2020). The facility has since been decommissioned and dismantled, and therefore no facility is currently licensed for the fabrication of TRISO fuels in the United States. In 2002, the DOE
43 established the Advanced Gas Reactor Fuel Development and Qualification Program, which one of its objectives is to establish domestic TRISO particle fuel manufacturing capabilities in support of prismatic and pebble-bed HTGR fuel designs (Mitchell, et al.,
2020). Under this program, TRISO particles with UCO kernels enriched to 19.7 percent 235U have been fabricated. The target quality level for TRISO-coated particle fuel is based on the quality level achieved for a fuel particle design (EUO 2358-2365) in a German program during the late 1980s. A follow-on assessment may include an evaluation of the chemical processes and hazards for the fabrication of TRISO-coated pebbles under this ongoing DOE program.
Thorium-232 Production. A preliminary review of the literature has not identified the need or particular method for the enrichment of 232Th to remove traces amounts of other thorium isotopes (e.g.,230Th,229Th) in support of MSR breeders. Various reactors incorporating thorium-based fuels have been deployed internationally, including three in the United States (NEA & IAEA, 2016). A follow-on assessment may include a review of documents pertinent to front-end activities for those reactors, which could provide more details on any implemented processes for the purification of 232Th. The need for this assessment should be informed by vendor needs.
Graphite Performance. A key technical concern related to MSR performance continues to be the limited lifetime of graphite materials in the reactor core. Although this does not present a technical issue for front-end activities in new MSR fuel cycles, consideration should be provided to the generation and management of irradiated graphite waste and implications to future safety reviews for its storage, transportation, and eventual disposal.
Materials Compatibility. The production of halide-based fuels and mixing with commercial non-radioactive salts will require adequate materials to support high temperature operations and limit the generation of impurities in these processes. The need for new materials for transportation package designs may need to be reviewed per the requirements for normal conditions of transport and hypothetical accident conditions.
The review could include an assessment of compatibility of previously used materials such as Inconel and Hastelloy N, as well as other mitigation strategies for degradation that could be implemented.
DOE Engagement. Continued engagement with DOE will support NRCs understanding of activities in support of MSRs, including the Advanced Reactor Demonstration Program (ARDP), the Research Reactor Infrastructure Program (RRIP), the Gateway for Accelerated Innovation in Nuclear (GAIN) Program and the Advanced Gas Reactor Fuel Development and Qualification Program.
Assessment of other domestic and international MSR technologies under development. A follow-on assessment may evaluate technical considerations for MSR technologies under development by other commercial vendors that have not yet engaged with the NRC on pre-application engagements. These include the Stable Salt Reactor (under development by Moltex Energy), the Molten Chloride Salt Fast Reactor (under development by Elysium Industries), the Thorium Molten Salt Reactor 500 (under
44 development by ThorCon Power), the Mu*STAR accelerator-driven small modular reactor (under development by Muons), and the Micro Molten Salt Reactor (ARC Generator) under development by Alpha Tech Research Corp. In addition, the review could assess MSR technologies under development by international organizations and countries, such as the Molten Salt Fast Reactor (SAMOFAR) project funded by European Atomic Energy Commission (Euratom), the Molten Salt Actinide Recycler and Transmuter (MOSART) concept explored by the Russian Federation, the thorium-fueled liquid fluoride MSR to be operated by the Peoples Republic of China, and the thorium-fueled molten salt breeder reactor designed by the Republic of India.
45 6 REFERENCES AEC. The Use of Thorium in Nuclear Power Reactors, Report No. WASH-1097. Washington, DC: U.S. Atomic Energy Commission. 1969.
AEC. An Evaluation of the Molten Salt Breeder Reactor, Report No. WASH-1222. Washington, DC: U.S. Atomic Energy Commission. 1972.
Aleksandrov, B.P., E.B. Gordon, A.V. Ivanov, A.A. Kotov, and V.E. Smirnov. Reduction of Uranium Hexafluoride to Tetrafluoride by Using the Hydrogen Atoms, Journal of Physics:
Conference Series, Volume 751, Article No. 012012. 2016.
ANSI. Nuclear Materials - Uranium Hexafluoride - Packagings for Transport, ANSI Standard N14.1-2019. New York, NY: American National Standards Institute. 2019.
Baes, C.F. The Chemistry and Thermodynamics of Molten Salt Reactor Fuels, Report No.
Conf-730701. Oak Ridge, TN: Oak Ridge National Laboratory. 1974.
Bahri, C., A.F. Ismail, and A.A. Majid. Synthesis of Thorium Tetrafluoride (ThF4) by Ammonium Hydrogen Difluoride (NH4HF2), Nuclear Engineering and Technology, Volume 51, Issue 3, pp. 792-799. 2019.
Bradley, D. The Preparation and Properties of the Chlorides of Uranium, Plutonium, Thorium, and of the Fission Product Chlorides, Report No. A.E.R.E. CE/R 2215. United Kingdom Atomic Energy Authority Research Group. 1957.
Briggs, G.G. and J.H. Cavendish. Thorium Metal Production, Report No. NLCO-1080.
Cincinnati, OH: National Lead Company of Ohio. 1971.
Cantor, S., J.W. Cooke, A.S. Dworkin, G.D. Robbins, R.E. Thoma, and G.M. Watson. Physical Properties of Molten-Salt Reactor Fuel, Coolant, and Flush Salts, Report No. ORNL-TM-2316.
Oak Ridge, TN: Oak Ridge National Laboratory. 1968.
Cottrell, W.B., H.E. Hungerford, J.K. Leslie, and J.L. Meem. Operation of the Aircraft Reactor Experiment. Oak Ridge, TN: Oak Ridge National Laboratory. 1955.
Demkowicz, P.A., B. Liu, and J.D. Hunn. Coated Particle Fuel: Historical Perspectives and Current Progress. Journal of Nuclear Materials. Volume 515. pp. 434-450. 2019.
DOE. Certificate of Compliance for Radioactive Materials Package USA/9315/B(U)F-96, Rev. 18, Compliance Number 9315. Washington, DC: Department of Energy. 2021.
DOT. Competent Authority Certification for A Type Fissile Radioactive Material Package Design Certificate USA/0412/AF-96, Rev. 17. Washington, DC: U.S. Department of Transportation. 2019a.
46 DOT. Competent Authority Certification for a Type B(U)F Fissile Radioactive Material Package Design Certificate USA/0492/B(U)F-96, Rev. 20. Washington, DC: U.S. Department of Transportation. 2019b.
Elsheikh, B.M. Safety Assessment of Molten Salt Reactors in Comparison to Light Water Reactors, Journal of Radiation Research and Applied Sciences, Volume 6, Issue 2, pp. 63-70.
2013.
EPRI. Program on Technology Innovation: Technology Assessment of a Molten Salt Reactor Design - The Liquid-Fluoride Thorium Reactor, Technical Report No. 3002005460. Palo Alto, CA: Electric Power Research Institute. 2015.
EPRI. Uranium Oxycarbide Tristructural Isotropic-Coated Particle Fuel Performance, Report No. EPRI-AR-1(NP)-A. Palo Alto, CA: Electric Power Research Institute. 2020.
Flibe. LFTR Technology, accessed Aug 2021, https://flibe-energy.com/lftr/. Huntsville, AL:
Flibe Energy. 2021.
Fredrickson, G., G. Cao, R, Gakhar, and T. Yoo. Molten Salt Reactor Salt Processing -
Technology Status, Report No. INL/EXT-18-51033. Idaho Falls, ID: Idaho National Laboratory.
2018.
Hall, N., X. He, Y. Pan, and P. LaPlante. Review of Operating Experience for Transportation of Fresh (Unirradiated) Advanced Reactor Fuel Types. ADAMS Accession No. ML20184A151.
San Antonio, TX: Center for Nuclear Waste Regulatory Analyses. 2019a.
Hall, N., X. He, Y. Pan, and P. LaPlante. Potential Challenges with Transportation of Fresh (Unirradiated) Advanced Reactor Fuel Types. ADAMS Accession No. ML20209A541. San Antonio, TX: Center for Nuclear Waste Regulatory Analyses. 2019b.
Harris, K. Overview of LFTR: Materials and Components, ADAMS Accession No. ML20030B768. Huntsville, AL: Flibe Energy. 2015.
Hastings, P. Principal Design Criteria for the Kairos Power Fluoride Salt-Cooled, High Temperature Reactor. ADAMS Accession No. ML20167A174. Alameda, CA: Kairos Power LLC. 2020.
Haubenreich, P.N. and J.R. Engel. Experience with the Molten-Salt Reactor Experiment, Nuclear Applications and Technology, Volume 8, Issue 2, pp. 118-136. 1970.
Haugh, B. Kairos Power Overview, ORNL MSR Workshop. Alameda, CA: Kairos Power LLC.
2021.
Hill, D. IMSR Commercialization before 2030, GAIN Molten Salt Reactor Workshop. Charlotte, NC: Terrestrial Energy. 2020.
47 IAEA. Manual on Safe Production, Transport, Handling and Storage of Uranium Hexafluoride, Report No. IAEA-TECDOC-771. Vienna, Austria: International Atomic Energy Agency. 1994.
IAEA. Thorium Fuel Cycle - Potential Benefits and Challenges, Report No.
IAEA-TECDOC-1450. Vienna, Austria: International Atomic Energy Agency. 2005.
IAEA. High Temperature Gas Cooled Reactor Fuels and Materials. Report No.
IAEA-TECDOC-1645. Vienna, Austria: International Atomic Energy Agency. 2010.
IAEA. Regulations for the Safe Transport of Radioactive Material, Specific Safety Requirements No. SSR-6. Vienna, Austria: International Atomic Energy Agency. 2012.
IBI. Thorium Fluoride, TH4 For Optical Coating, accessed Oct 2021, http://ibilabs.com/uranium-uranyl-thorium-compounds/thorium-compounds/thorium-fluoride/. International Bio-Analytical Industries, Inc. 2014.
Johnson, O., T. Butler, J. Powell, and R. Nottorf. A Summary of the Properties, Preparation, and Purification of the Anhydrous Chlorides and Bromides of Uranium, Report No. CC-1974.
Washington, DC: U.S. Atomic Energy Commission. 1944.
Kairos. KP-FHR Fuel Performance Methodology, Report No. KP-TR-010-NP, Revision 3 Docket No. 99902069. ADAMS Accession No. ML21162A351. Alameda, CA: Kairos Power LLC. 2020a.
Kairos. Technology, accessed July 2021, https://kairospower.com/technology/. Alameda, CA:
Kairos Power LLC. 2020b.
Lambert, H., T. Kerry, and C.A. Sharrad. Preparation of Uranium (III) in a Molten Chloride Salt:
A Redox Mechanistic Study, Journal of Radioanalytical and Nuclear Chemistry, Volume 317, pp. 925-932. 2018.
Latkowski, J. TerraPowers Molten Chloride Fast Reactor. The National Academies of Sciences, Engineering, and Medicine, Nuclear and Radiation Studies Board, Merits and Viability of Different Nuclear Fuel Cycles and Technology Options and the Waste Aspects of Advanced Nuclear Reactors: February 22 and 23, 2021.
https://www.nationalacademies.org/event/02 2021/docs/DB0D308269688B2BD7B1AF60BAA143D48890C2DE80BB Le Brun, C. Molten Salts and Nuclear Energy Production, Journal of Nuclear Materials, Volume 317, Issue 1, pp. 1-5. 2007.
Mallapaty, S. China Prepares to Test Thorium-Fueled Nuclear Reactor, accessed Oct 2021.
https://www.nature.com/articles/d41586-021-02459-w. 2021.
Martoyan, G.A., M.M. Kalugin, A.V. Gabrielyan, and A.G. Martoyan. Prospects of Lithium Enrichment on 7Li Isotope by Method of Controlled Ions Electro-Migration, IOP Conference Series: Materials Science and Engineering, Volume 112, Article No. 012035. 2016.
48 McFarlane, J., P. Taylor, D. Holcomb, and W.P. Poore. Review of Hazards Associated with Molten Salt Reactor Fuel Processing Operations, Report No. ORNL/TM-2019/1195. ADAMS Accession No. ML19205A386. Oak Ridge, TN: Oak Ridge National Laboratory. 2019.
Mitchell, T.R., G. Strydom, M.T. Sharp, and P.A. Demkowicz. Technical Program Plan for INL Advanced Reactor Technologies Advanced Gas Reactor Fuel Development and Qualification Program, Report No. INL/MIS-10-20662. Idaho Falls, ID: Idaho National Laboratory. 2020.
NEA & IAEA. Uranium 2016: Resources, Production, and Demand. Joint Report by the Nuclear Energy Agency and the International Atomic Energy Agency. 2016.
NRC. Standard Review Plan for Fuel Cycle Facilities License Applications - Final Report (NUREG-1520), Rev. 2. Washington, DC: U.S. Nuclear Regulatory Commission. 2015.
NRC. NRC Non-Light Water Reactor Near-Term Implementation Action Plans, ADAMS Accession No. ML17165A069. Washington, DC: U.S. Nuclear Regulatory Commission. 2017.
NRC. U.S. Nuclear Regulatory Commission Safety Evaluation Report for the High-Assay Low-Enriched Uranium Demonstration Program at Centrus Energy Corp./American Centrifuge Operating, LLCs American Centrifuge Plant in Piketon, Ohio, ADAMS Accession No. ML21148A291. Washington, DC: U.S. Nuclear Regulatory Commission. 2021.
ORNL. 2021 Virtual Molten Salt Reactor Workshop, accessed July 2021.
https://msrworkshop.ornl.gov/. 2021.
OSHA. OSHA Occupational Chemical Database, accessed Nov. 2021.
https://www.osha.gov/chemicaldata/. 2021.
Peretz, F.J. Identification and Evaluation of Alternatives for the Disposition of Fluoride Fuel and Flush Salts from the Molten Salt Reactor Experiment at Oak Ridge National Laboratory, Oak Ridge, Tennessee, Report No. ORNL/ER-380. Oak Ridge, TN: Oak Ridge National Laboratory.
1996.
Richards, M. Assessment of GT-MHR Spent Fuel Characteristics and Repository Performance, Report No. PC-000502, Rev. 0. San Diego, CA: General Atomics. 2002.
Rosenthal, M.W., P.R. Kasten and R.B. Briggs. Molten-Salt Reactors - History, Status and Potential, Nuclear Applications and Technology, Volume 8, Issue 2, pp. 107-117. 1970.
Rosenthal, M.W. An Account of Oak Ridge National Laboratorys Thirteen Nuclear Reactors, Report No. ORNL/TM-2009/181. Oak Ridge, TN: Oak Ridge National Laboratory. 2010.
Schubert, P. Abilene Christian Universitys Molten Salt Research Reactor Regulatory Engagement Plan, Docket No. 99902088. ADAMS Accession No. ML20241A071. Abilene, TX:
Abilene Christian University. 2020.
49 Shaffer, J.H. Preparation and Handling of Salt Mixtures for the Molten Salt Reactor Experiment, Report No. ORNL-4616. Oak Ridge, TN: Oak Ridge National Laboratory. 1971.
Song, J. Thorium Molten Salt Reactor: A Safe Way Out for Nuclear Energy. Bulletin of the Chinese Academy of Sciences, Volume 26, No.3. 2012.
Sorenson, K.F. Thorium Research in the Manhattan Project Era. Knoxville, TN: University of Tennessee. 2014.
Souek, P., O. Bene, B. Claux, E. Capelli, M. Ougier, V. Tyrpekl, J. Vigier, and R. Konings.
Synthesis of UF4 and ThF4 by HF Gas Fluorination and Re-determination of the UF4 Melting Point, Journal of Fluorine Chemistry, Volume 200, pp. 33-40. 2017.
TerraPower. Reflectors for Molten Chloride Fast Reactors, United States Patent Application 20200027590. Bellevue, WA: TerraPower LLC. 2020.
TerraPower. Molten Chloride Fast Reactor Technology, accessed Aug 2021.
https://www.terrapower.com/our-work/molten-chloride-fast-reactor-technology/. Bellevue, WA:
TerraPower LLC. 2021.
Terrestrial. How Do Molten Salt Reactors Work?: Inside IMSR Technology, accessed Oct.
2021, https://www.terrestrialenergy.com/technology/molten salt-reactor/. Charlotte, NC:
Terrestrial Energy. 2021a.
Terrestrial. Terrestrial Energy, Westinghouse, UK NNL Sign Nuclear Fuel Supply Agreement, accessed July 2021, https://www.terrestrialenergy.com/2021/08/17/terrestrial-energy-westinghouse-and-uk-national-nuclear-laboratory-sign-agreement-for-imsr-nuclear-fuel-supply/.
Charlotte, NC: Terrestrial Energy. 2021b.
Towell, R. Introductions, Licensing Pathway, and Technical Summary, Docket No. 99902088.
ADAMS Accession No. ML20280A315. Abilene, TX: Abilene Christian University. 2020.
U.S. Congress. Nuclear Energy Innovation Capabilities Act of 2017, Public Law 115-248, 42 U.S.C. 10101, 16021, 16271, 16272, 16273, 16274, 16275, 16276, 16277, 16352, 2210, and 5842. Washington, DC: U.S. Congress. 2017.
Vidal, E.E. Materion Flibe/Flinabe Salts. 5th Annual Future of Energy Conference.
https://thoriumenergyalliance.com/wp-content/uploads/2020/02/Vidal_Thorium-Symp-2013.pdf.
Mayfield Heights, OH: Materion. 2013.
Williams, D.F. and P.F. Britt. Technology and Applied R&D Needs for Molten Salt Chemistry -
Innovative Approaches to Accelerate Molten Salt Reactor Development and Deployment; Molten Salt Chemistry Workshop, April 10-12, 2017. Oak Ridge, TN: Oak Ridge National Laboratory. 2017.
50 Yoo, T., G.L. Fredrickson, and G.M. Teske. Uranium Exchange Kinetics in a Molten LiCl-KCl/Cd System at 500°C, Report No. INL/JOU-18-44721. Idaho Falls, ID: Idaho National Laboratory. 2018.