Letter Sequence Supplement |
|---|
|
Results
Other: ML21054A051, ML21125A143, ML21125A144, ML21138A852, ML21279A184, ML21279A187, ML21279A190, ML21322A121, ML21322A124, ML21322A127, ML22006A352, ML22006A353, ML22006A354, ML22006A356, ML22055A629, ML22091A162, ML22103A068, ML22104A265, ML22104A266, ML22118A855, ML22118A856, ML22118B144, ML22123A162, ML22123A163, ML22123A207, ML22123A242, ML22123A244
|
MONTHYEARML21054A0512021-02-23023 February 2021 5 of the TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the Halfpact Shipping Package Application, Docket No. 71-9279 Project stage: Other ML22123A1622021-02-28028 February 2021 Redacted-Revision 25 of the Safety Analysis Report for the Model No TRUPACT-II, February 2021 Project stage: Other ML21054A0542021-02-28028 February 2021 CH-TRAMPAC R6 - February 2021 Project stage: Request ML21138A8522021-05-18018 May 2021 5/5/21, 1:00PM (Est), Summary for Conference Call to Discuss Identfied Request for Supplemental Information, Model Nos. TRUPACT-II, Rev. 26, and Halfpact, Rev. 10 Project stage: Other ML21125A1442021-05-20020 May 2021 Enclosure (Observations) - Application for the Model Nos. Trupact-II and Halfpact Transport Packages - Accepted for Review (EPIDs L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: Other ML21125A1432021-05-20020 May 2021 Transmittal Letter - Application for the Model Nos. Trupact-II and Halfpact Transport Packages - Accepted for Review (EPIDs L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: Other ML21214A1452021-08-11011 August 2021 Transmittal Letter Request for Additional Information, Model Nos Trupact II and Halfpact Transport Packages Project stage: RAI ML21214A1462021-08-11011 August 2021 2. Enclosurequest for Additional Information Model Nos. TRUPACT-II and Halfpact (EPIDs L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: RAI ML21279A1902021-09-28028 September 2021 HPT-REP-0001,Regulatory Hypothetical Accident Condition Type B Testing for the Halfpact Shielded Container Payloads, Rev. 1, September 2021 Project stage: Other ML21279A1842021-10-0606 October 2021 CH-TRAMPAC, Revision 6, October 2021 Project stage: Other ML21279A1872021-10-0606 October 2021 CH-TRU Payload Appendices, Revision 5, October 2021 Project stage: Other ML21279A1812021-10-0606 October 2021 Transmittal Letter: Response to Request for Additional Information for Revision 25 of the TRUPACT-II Shipping Package Application, Docket No.71-9218,and Revision 8 of the Halfpact Shipping Package Application, Docket No.71-9279 Project stage: Response to RAI ML22123A2072021-10-0606 October 2021 Redacted-Revision 25 of the Safety Analysis Report for the Model No. TRUPACT-II, October 2021 Project stage: Other ML22123A2422021-10-0606 October 2021 Redacted-Revision 8 of the Safety Analysis Report for the Model No. Halfpact Package (Certificate of Compliance No. 9279, Revision 10) - October 2021 Project stage: Other ML21322A1212021-11-18018 November 2021 Nuclear Waste Partnership, Revision 25 of the TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the Halfpact Shipping Package Application, Docket No. 71-9279 (Epids L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: Other ML22123A1632021-11-18018 November 2021 Redacted-Revision 25 of the Safety Analysis Report for the Model No. TRUPACT-II, November 2021 Project stage: Other ML22006A3502021-11-29029 November 2021, 27 December 2021, 6 January 2022, 8 February 2022, 14 March 2022 12/1/21-Conference Call with Nuclear Waste Partners LLC and the U.S. Department of Energy-Discuss Follow Up Questions Related to Shielding RAIs RAI-Sh-5 and -8, Model Nos. TRUPACT-II and Halfpact (Docket Nos. 71-9218 and 71-9279; EPID L-202 Project stage: Request ML22006A3542021-11-29029 November 2021 Enclosure 1: Transmittal Email Dated 11/29/21, Follow Up Questions and Responses Related to Acceptance Tests (Shielded Canisters), Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML21322A1242021-11-30030 November 2021 Nuclear Waste Partnership, CH-TRAMPAC, Revision 6, November 2021 Project stage: Other ML21322A1272021-11-30030 November 2021 Nuclear Waste Partnership, CH-TRU Payload Appendices, Revision 5, November 2021 Project stage: Other ML22123A2442021-11-30030 November 2021 Redacted - Revision 8 of the Safety Analysis Report for the Model No. Halfpact Package (Certificate of Compliance No. 9279, Revision 10) - November 2021 Project stage: Other ML22103A0642021-12-0909 December 2021, 28 January 2022 Email from S. Burns to N. Garcia Dated January 28, 2021 Responses to RAI Follow Up Questions Related to the Shielding Evaluation for Revision 10 of the Certificate of Compliance for the Model No. Halfpact Package Project stage: Request ML22103A0682021-12-0909 December 2021 NRC Staff Follow Up Questions Related to the Shielding Evaluation for Revision 10 of the Certificate of Compliance for the Model No. Halfpact Package Project stage: Other ML22006A3512021-12-27027 December 2021 Enclosure 4: Nwps (Applicants) Comments on the Summary of the Teleconference Dated December 1, 2021 Related to Shielding RAIs (Acceptance Tests), Model Nos. TRUPACT-II and Halfpact Packages Project stage: Meeting ML22006A3522021-12-27027 December 2021 Enclosure 3: Email Dated 12/27/21 from S. Burns (Nwp) to N. Garcia Santos (Nrc), Comments on Telephone Call Summary Dated 12/1/21, Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3532021-12-27027 December 2021 Enclosure 2: Attachment to Email Dated 11-29-21, Responses to Follow Up Questions, Acceptance Tests for the Lead Ssield of the Shielded Canisters (Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3562021-12-27027 December 2021 Enclosure 5: Clarification Regarding Testing Performed During the Shielded Container Prototype Testing (Drop Tests, Gamma Scans, Destructive Disassembly), Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3552022-01-0606 January 2022 12/1/21-Conference Call Summary: Follow Up Questions Related to Shielding RAIs RAI-Sh-5 and -8 (Acceptance Tests, Shielded Canisters), Model Nos. TRUPACT-II and Halfpact Packages Project stage: RAI ML22103A0702022-01-28028 January 2022 Attachment--Email from S. Burns to N. Garcia Dated January 28, 2021 Responses to RAI Follow Up Questions Related to the Shielding Evaluation for Revision 10 of the Certificate of Compliance for the Model No. Halfpact Package Project stage: Response to RAI ML22103A0692022-01-28028 January 2022 Email from S. Burns to N. Garcia Dated January 28, 2021 Responses to RAI Follow Up Questions Related to the Shielding Evaluation for Revision 10 of the Certificate of Compliance for the Model No. Halfpact Package Project stage: Response to RAI ML22091A1622022-02-0808 February 2022 Email Dated 2/8/2022 from S. Burns (Nwp) to N. Garcia Santos (Nrc), Estimated Date to Submit Letter with Responses to the Follow Up Questions Discussed on December 1st, 2021 Telephone Call (Model Nos. TRUPACT-II and Halfpact Packages) Project stage: Other ML22055A6292022-02-24024 February 2022 Transmittal Letter: TRUPACT-II Package Application, Revision 25, Docket No. 71-9218, and Halfpact Package Application, Revision 8, Docket No. 71-9279 (Epids L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: Other ML22055A6332022-02-28028 February 2022 Nuclear Waste Partnership, LLC, CH-TRU Payload Appendices, Revision 5 Project stage: Request ML22055A6322022-02-28028 February 2022 Nuclear Waste Partnership, LLC, CH-TRAMPAC, Revision 6 Project stage: Request ML22091A1632022-03-14014 March 2022 Email Dated 3/14/2022, from S. Burns (Nwp) to N. Garcia Santos, Response to NRC Staffs Follow Up Question on Supplemental RAI Responses Dated 2/24/22 Shielded Container Lid and Bases Lead (Model Nos. TRUPACT-II and Halfpact) Project stage: Supplement ML22118B0142022-04-14014 April 2022 Attachment 3 to Email Dated 4/14/22 from Sburns (Nwp) to Ngarcia Santos (NRC) Courtesy Review - Comments from Nwp on Draft Certificate of Compliance No. 9218, Revision 26 Project stage: Draft Other ML22118B0132022-04-14014 April 2022 Attachment 2 to Email Dated 4/14/22 from Sburns (Nwp) to Ngarcia Santos (NRC) Courtesy Review - Summary of Combined Comments from Nwp on Draft Certificate of Compliance No. 9279, Revision 10 Project stage: Draft Other ML22118B0152022-04-14014 April 2022 Attachment 4 to Email Dated 4/14/22 from Sburns (Nwp) to Ngarcia Santos (NRC) Courtesy Review - Summary Combined Comments from Nwp on Draft Certificate of Compliance No. 9279, Revision 10 Project stage: Draft Other ML22118B0122022-04-14014 April 2022 Attachment 1 to Email Dated 4/14/22 from Sburns (Nwp) to Ngarcia Santos (NRC) Courtesy Review - Combined Comments from Nwp on Draft Certificate of Compliance No. 9279, Revision 10 Project stage: Draft Other ML22118A8562022-04-14014 April 2022 Email Dated 04/14/2022 from S. Burns (Nwp) to N. Garcia Santos (NRC) Subject--Renewal and Courtesy Review Certificate of Compliance Nos. 9279 and 9218 Project stage: Other ML22118A8552022-04-14014 April 2022 Email Dated 04/14/2022 from Sburns (Nwp) to Ngarcia Santos, Subject--Courtesy Review of Certificate of Compliance Nos. 9279 and 9218 Project stage: Other ML22118B1442022-04-28028 April 2022 Transmittal: Letter Certificate of Compliance No. 9218, Rev. 26, Model No. TRUPACT-II and Certificate of Compliance No. 9279, Rev. 10, Model No. Halfpact Transport Packages Project stage: Other ML22104A2672022-04-28028 April 2022 Enclosure 3 - Safety Evaluation Report, Certificate of Compliance No. 9218, Rev. 26, Model No. TRUPACT-II and Certificate of Compliance No. 9279, Rev. 10, Model No. Halfpact Transport Packages Project stage: Approval ML22104A2662022-04-28028 April 2022 Enclosure 1 - Revision No. 26 of Certificate of Compliance No. 9218 for the Model No. TRUPACT-II Transport Packages Project stage: Other ML22104A2652022-04-28028 April 2022 Enclosure 2 - Revision No. 10 of Certificate of Compliance No. 9279 for the Model No. Halfpact Trasport Packages Project stage: Other 2021-05-20
[Table View] |
Text
From:
Burns, Scott - NWP - NTP To:
Garcia Santos, Norma; Porter, Steve - NWP; Sellmer, Todd - NWP Cc:
Allen, William; White, Bernie; Smith, DaBrisha - CBFO
Subject:
[External_Sender] RE: TRUPACT-II and HalfPACT-QUERY: Shielded Container Lid and Bases Lead Question Date:
Monday, March 14, 2022 1:21:42 PM
- Norma,
I hope your day is going well. Please see the below response to the question provided this morning.
Unlike the cast lead in the container sidewall where visual examination of shielding efficacy is impossible, installation of the lead plates and rings in the containers base and lid allow for visual examination to verify that gaps are filled. As stated, the lead plates/rings are either press-fit into place or lead wool is installed (i.e., pounded) into radial gaps to eliminate such gaps, should they be present. Visual examination is performed to verify that radial gaps are either not present or have been properly filled prior to installation of the associated cover plates.
Please let me know if you need anything else.
- Thanks, Scott Scott Burns Packaging Engineer Cell: (575) 706-7920 Office: (575) 234-7091 Nuclear Waste Partnership LLC l Contractor for the U.S. Department of Energy 4021 National Parks Highway l PO Box 2078 l Mail Stop GSA-211 Carlsbad NM 88220
From: Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>
Sent: Monday, March 14, 2022 3:33 AM To: Porter, Steve - NWP <steve.porter@wipp.ws>; Sellmer, Todd - NWP <Todd.Sellmer@wipp.ws>;
Burns, Scott - NWP - NTP <Scott.Burns@wipp.ws>
Cc: Allen, William <William.Allen@nrc.gov>; White, Bernie <Bernard.White@nrc.gov>
Subject:
TRUPACT-II and HalfPACT-QUERY: Shielded Container Lid and Bases Lead Question
WARNING - EXTERNAL EMAIL This message does not originate from a known WIPP email system.
Use caution if this message contains attachments, links or requests for information.
Good morning,
The staff has an additional question related to testing the top and the bottom lids (see the question below). Please email me your response. I will provide it to the staff and add it to the docket. If necessary, I can schedule a meeting.
Thanks and have a nice rest of the day, Norma
From: Allen, William <William.Allen@nrc.gov>
Sent: Friday, March 11, 2022 2:12 PM To: Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>
Cc: Diaz Maldonado, Marilyn <marilyn.diazmaldonado@nrc.gov>; Thomlinson, Aaron
<Aaron.Thomlinson@nrc.gov>
Subject:
Shielded Container Lid and Bases Lead Question
- Norma,
Below is the question Id like you to send to the applicant. Let me know if you have any questions.
Chris
The shielded container drawings identify that the lead in the lids and bases is press-fit with the option of using lead wool to establish a tight fit. Either explain how the absence of gaps, seams, etc.
in the lead shielding of the shielded container lids and bases is confirmed, or provide justification for not performing a volumetric test for the lead shielding in the lid and base of the shielded container similar to that performed for the shielded container sidewall lead?
Let us cross the river and rest in the shade of the trees.