Other: ML21054A051, ML21125A143, ML21125A144, ML21138A852, ML21279A184, ML21279A187, ML21279A190, ML21322A121, ML21322A124, ML21322A127, ML22006A352, ML22006A353, ML22006A354, ML22006A356, ML22055A629, ML22091A162, ML22103A068, ML22104A265, ML22104A266, ML22118A855, ML22118A856, ML22118B144, ML22123A162, ML22123A163, ML22123A207, ML22123A242, ML22123A244
|
MONTHYEARML21054A0512021-02-23023 February 2021 5 of the TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the Halfpact Shipping Package Application, Docket No. 71-9279 Project stage: Other ML21054A0542021-02-28028 February 2021 CH-TRAMPAC R6 - February 2021 Project stage: Request ML22123A1622021-02-28028 February 2021 Redacted-Revision 25 of the Safety Analysis Report for the Model No TRUPACT-II, February 2021 Project stage: Other ML21138A8522021-05-18018 May 2021 5/5/21, 1:00PM (Est), Summary for Conference Call to Discuss Identfied Request for Supplemental Information, Model Nos. TRUPACT-II, Rev. 26, and Halfpact, Rev. 10 Project stage: Other ML21125A1442021-05-20020 May 2021 Enclosure (Observations) - Application for the Model Nos. Trupact-II and Halfpact Transport Packages - Accepted for Review (EPIDs L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: Other ML21125A1432021-05-20020 May 2021 Transmittal Letter - Application for the Model Nos. Trupact-II and Halfpact Transport Packages - Accepted for Review (EPIDs L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: Other ML21214A1462021-08-11011 August 2021 2. Enclosurequest for Additional Information Model Nos. TRUPACT-II and Halfpact (EPIDs L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: RAI ML21214A1452021-08-11011 August 2021 Transmittal Letter Request for Additional Information, Model Nos Trupact II and Halfpact Transport Packages Project stage: RAI ML21279A1902021-09-28028 September 2021 HPT-REP-0001,Regulatory Hypothetical Accident Condition Type B Testing for the Halfpact Shielded Container Payloads, Rev. 1, September 2021 Project stage: Other ML22123A2072021-10-0606 October 2021 Redacted-Revision 25 of the Safety Analysis Report for the Model No. TRUPACT-II, October 2021 Project stage: Other ML21279A1842021-10-0606 October 2021 CH-TRAMPAC, Revision 6, October 2021 Project stage: Other ML21279A1872021-10-0606 October 2021 CH-TRU Payload Appendices, Revision 5, October 2021 Project stage: Other ML22123A2422021-10-0606 October 2021 Redacted-Revision 8 of the Safety Analysis Report for the Model No. Halfpact Package (Certificate of Compliance No. 9279, Revision 10) - October 2021 Project stage: Other ML21279A1812021-10-0606 October 2021 Transmittal Letter: Response to Request for Additional Information for Revision 25 of the TRUPACT-II Shipping Package Application, Docket No.71-9218,and Revision 8 of the Halfpact Shipping Package Application, Docket No.71-9279 Project stage: Response to RAI ML21322A1212021-11-18018 November 2021 Nuclear Waste Partnership, Revision 25 of the TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the Halfpact Shipping Package Application, Docket No. 71-9279 (Epids L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: Other ML22123A1632021-11-18018 November 2021 Redacted-Revision 25 of the Safety Analysis Report for the Model No. TRUPACT-II, November 2021 Project stage: Other ML22006A3542021-11-29029 November 2021 Enclosure 1: Transmittal Email Dated 11/29/21, Follow Up Questions and Responses Related to Acceptance Tests (Shielded Canisters), Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3502021-11-29029 November 2021, 27 December 2021, 6 January 2022, 8 February 2022, 14 March 2022 12/1/21-Conference Call with Nuclear Waste Partners LLC and the U.S. Department of Energy-Discuss Follow Up Questions Related to Shielding RAIs RAI-Sh-5 and -8, Model Nos. TRUPACT-II and Halfpact (Docket Nos. 71-9218 and 71-9279; EPID L-202 Project stage: Request ML22123A2442021-11-30030 November 2021 Redacted - Revision 8 of the Safety Analysis Report for the Model No. Halfpact Package (Certificate of Compliance No. 9279, Revision 10) - November 2021 Project stage: Other ML21322A1242021-11-30030 November 2021 Nuclear Waste Partnership, CH-TRAMPAC, Revision 6, November 2021 Project stage: Other ML21322A1272021-11-30030 November 2021 Nuclear Waste Partnership, CH-TRU Payload Appendices, Revision 5, November 2021 Project stage: Other ML22103A0642021-12-0909 December 2021, 28 January 2022 Email from S. Burns to N. Garcia Dated January 28, 2021 Responses to RAI Follow Up Questions Related to the Shielding Evaluation for Revision 10 of the Certificate of Compliance for the Model No. Halfpact Package Project stage: Request ML22103A0682021-12-0909 December 2021 NRC Staff Follow Up Questions Related to the Shielding Evaluation for Revision 10 of the Certificate of Compliance for the Model No. Halfpact Package Project stage: Other ML22006A3522021-12-27027 December 2021 Enclosure 3: Email Dated 12/27/21 from S. Burns (Nwp) to N. Garcia Santos (Nrc), Comments on Telephone Call Summary Dated 12/1/21, Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3532021-12-27027 December 2021 Enclosure 2: Attachment to Email Dated 11-29-21, Responses to Follow Up Questions, Acceptance Tests for the Lead Ssield of the Shielded Canisters (Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3512021-12-27027 December 2021 Enclosure 4: Nwps (Applicants) Comments on the Summary of the Teleconference Dated December 1, 2021 Related to Shielding RAIs (Acceptance Tests), Model Nos. TRUPACT-II and Halfpact Packages Project stage: Meeting ML22006A3562021-12-27027 December 2021 Enclosure 5: Clarification Regarding Testing Performed During the Shielded Container Prototype Testing (Drop Tests, Gamma Scans, Destructive Disassembly), Model Nos. TRUPACT-II and Halfpact Packages Project stage: Other ML22006A3552022-01-0606 January 2022 12/1/21-Conference Call Summary: Follow Up Questions Related to Shielding RAIs RAI-Sh-5 and -8 (Acceptance Tests, Shielded Canisters), Model Nos. TRUPACT-II and Halfpact Packages Project stage: RAI ML22103A0692022-01-28028 January 2022 Email from S. Burns to N. Garcia Dated January 28, 2021 Responses to RAI Follow Up Questions Related to the Shielding Evaluation for Revision 10 of the Certificate of Compliance for the Model No. Halfpact Package Project stage: Response to RAI ML22103A0702022-01-28028 January 2022 Attachment--Email from S. Burns to N. Garcia Dated January 28, 2021 Responses to RAI Follow Up Questions Related to the Shielding Evaluation for Revision 10 of the Certificate of Compliance for the Model No. Halfpact Package Project stage: Response to RAI ML22091A1622022-02-0808 February 2022 Email Dated 2/8/2022 from S. Burns (Nwp) to N. Garcia Santos (Nrc), Estimated Date to Submit Letter with Responses to the Follow Up Questions Discussed on December 1st, 2021 Telephone Call (Model Nos. TRUPACT-II and Halfpact Packages) Project stage: Other ML22055A6292022-02-24024 February 2022 Transmittal Letter: TRUPACT-II Package Application, Revision 25, Docket No. 71-9218, and Halfpact Package Application, Revision 8, Docket No. 71-9279 (Epids L-2021-LLA-0033 and L-2021-LLA-0034) Project stage: Other ML22055A6322022-02-28028 February 2022 Nuclear Waste Partnership, LLC, CH-TRAMPAC, Revision 6 Project stage: Request ML22055A6332022-02-28028 February 2022 Nuclear Waste Partnership, LLC, CH-TRU Payload Appendices, Revision 5 Project stage: Request ML22091A1632022-03-14014 March 2022 Email Dated 3/14/2022, from S. Burns (Nwp) to N. Garcia Santos, Response to NRC Staffs Follow Up Question on Supplemental RAI Responses Dated 2/24/22 Shielded Container Lid and Bases Lead (Model Nos. TRUPACT-II and Halfpact) Project stage: Supplement ML22118A8562022-04-14014 April 2022 Email Dated 04/14/2022 from S. Burns (Nwp) to N. Garcia Santos (NRC) Subject--Renewal and Courtesy Review Certificate of Compliance Nos. 9279 and 9218 Project stage: Other ML22118B0152022-04-14014 April 2022 Attachment 4 to Email Dated 4/14/22 from Sburns (Nwp) to Ngarcia Santos (NRC) Courtesy Review - Summary Combined Comments from Nwp on Draft Certificate of Compliance No. 9279, Revision 10 Project stage: Draft Other ML22118B0142022-04-14014 April 2022 Attachment 3 to Email Dated 4/14/22 from Sburns (Nwp) to Ngarcia Santos (NRC) Courtesy Review - Comments from Nwp on Draft Certificate of Compliance No. 9218, Revision 26 Project stage: Draft Other ML22118B0132022-04-14014 April 2022 Attachment 2 to Email Dated 4/14/22 from Sburns (Nwp) to Ngarcia Santos (NRC) Courtesy Review - Summary of Combined Comments from Nwp on Draft Certificate of Compliance No. 9279, Revision 10 Project stage: Draft Other ML22118B0122022-04-14014 April 2022 Attachment 1 to Email Dated 4/14/22 from Sburns (Nwp) to Ngarcia Santos (NRC) Courtesy Review - Combined Comments from Nwp on Draft Certificate of Compliance No. 9279, Revision 10 Project stage: Draft Other ML22118A8552022-04-14014 April 2022 Email Dated 04/14/2022 from Sburns (Nwp) to Ngarcia Santos, Subject--Courtesy Review of Certificate of Compliance Nos. 9279 and 9218 Project stage: Other ML22104A2652022-04-28028 April 2022 Enclosure 2 - Revision No. 10 of Certificate of Compliance No. 9279 for the Model No. Halfpact Trasport Packages Project stage: Other ML22104A2662022-04-28028 April 2022 Enclosure 1 - Revision No. 26 of Certificate of Compliance No. 9218 for the Model No. TRUPACT-II Transport Packages Project stage: Other ML22104A2672022-04-28028 April 2022 Enclosure 3 - Safety Evaluation Report, Certificate of Compliance No. 9218, Rev. 26, Model No. TRUPACT-II and Certificate of Compliance No. 9279, Rev. 10, Model No. Halfpact Transport Packages Project stage: Approval ML22118B1442022-04-28028 April 2022 Transmittal: Letter Certificate of Compliance No. 9218, Rev. 26, Model No. TRUPACT-II and Certificate of Compliance No. 9279, Rev. 10, Model No. Halfpact Transport Packages Project stage: Other 2021-05-20
[Table View] |
|
---|
Category:E-Mail
MONTHYEARML23089A2572023-03-29029 March 2023 Email from Ngarcia Santos (NRC) to T.E. Sellmer (Simco), Subject: Structural and Operations - Staggered RAIs Pertaining to the Halfpact Letter Authorization ML23089A2582023-03-29029 March 2023 Email Attachment, Staggered Request for Additional Information (Structural Evaluation and Operating Procedures), Model No. Halfpact - One-time Letter Authorization ML22320A1032022-11-15015 November 2022 Email from S. Burns (Nwp) to N. Garcia Santos (Nrc), Subject-IMPORTANT, Courtesy Review, Revised Draft CoCs for the TRUPACT-II and Halfpact Packages ML22320A1042022-11-14014 November 2022 Nuclear Waste Partnership, LLC (Applicant), T Sellmer Comments on Draft Certificate of Compliance No. 9279, Revision 11 ML22278A0012022-10-0404 October 2022 Email from T. Sellmer (Nwp) to N. Garcia Santos (NRC) Et Al., Delay of RAI Response-CoC, Revision 27, Model No. TRUPACT-II and CoC, Revision 11, Model No. Halfpact CoCs ML22278A0072022-09-0808 September 2022 Email from T.E. Sellmer (Nwp) to N. Garcia Santos (NRC) Acknowledgement of Application for CoC, Revision 27, Model No. TRUPACT-II and CoC, Revision 11, Model No. Halfpact Packages ML22118A8562022-04-14014 April 2022 Email Dated 04/14/2022 from S. Burns (Nwp) to N. Garcia Santos (NRC) Subject--Renewal and Courtesy Review Certificate of Compliance Nos. 9279 and 9218 ML22118A8552022-04-14014 April 2022 Email Dated 04/14/2022 from Sburns (Nwp) to Ngarcia Santos, Subject--Courtesy Review of Certificate of Compliance Nos. 9279 and 9218 ML22091A1632022-03-14014 March 2022 Email Dated 3/14/2022, from S. Burns (Nwp) to N. Garcia Santos, Response to NRC Staffs Follow Up Question on Supplemental RAI Responses Dated 2/24/22 Shielded Container Lid and Bases Lead (Model Nos. TRUPACT-II and Halfpact) ML22091A1622022-02-0808 February 2022 Email Dated 2/8/2022 from S. Burns (Nwp) to N. Garcia Santos (Nrc), Estimated Date to Submit Letter with Responses to the Follow Up Questions Discussed on December 1st, 2021 Telephone Call (Model Nos. TRUPACT-II and Halfpact Packages) ML22103A0692022-01-28028 January 2022 Email from S. Burns to N. Garcia Dated January 28, 2021 Responses to RAI Follow Up Questions Related to the Shielding Evaluation for Revision 10 of the Certificate of Compliance for the Model No. Halfpact Package ML22006A3532021-12-27027 December 2021 Enclosure 2: Attachment to Email Dated 11-29-21, Responses to Follow Up Questions, Acceptance Tests for the Lead Ssield of the Shielded Canisters (Model Nos. TRUPACT-II and Halfpact Packages ML22006A3522021-12-27027 December 2021 Enclosure 3: Email Dated 12/27/21 from S. Burns (Nwp) to N. Garcia Santos (Nrc), Comments on Telephone Call Summary Dated 12/1/21, Model Nos. TRUPACT-II and Halfpact Packages ML22006A3512021-12-27027 December 2021 Enclosure 4: Nwps (Applicants) Comments on the Summary of the Teleconference Dated December 1, 2021 Related to Shielding RAIs (Acceptance Tests), Model Nos. TRUPACT-II and Halfpact Packages ML22006A3542021-11-29029 November 2021 Enclosure 1: Transmittal Email Dated 11/29/21, Follow Up Questions and Responses Related to Acceptance Tests (Shielded Canisters), Model Nos. TRUPACT-II and Halfpact Packages ML20316A0012020-09-28028 September 2020 Email from K. Moyant (Nwp) to N. Garcia Santos (NRC) - Follow Up to Telephone Call Regarding the Materials and Criticality Evaluations, TRUPACT-II (Rev. 25) and Halfpact (Rev. 9) 2023-03-29
[Table view] |
Text
From:
Burns, Scott - NWP - NTP To:
Garcia Santos, Norma; Porter, Steve - NWP; Sellmer, Todd - NWP Cc:
Allen, William; Smith, DaBrisha - CBFO
Subject:
[External_Sender] RE: ACTION: Review Responses to Questions: TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the HalfPACT Shipping Package Application, Docket No. 71-9279 Date:
Monday, November 29, 2021 2:17:08 PM Attachments:
Response to Test Acceptance Questions.pdf
- Norma, Please see the attached information to support the call set up for tomorrow.
- Thanks, Scott Scott Burns Packaging Engineer, (575) 234-7091 l Fax: (575) 234-7055 Working Remotely (575) 706-7920 Nuclear Waste Partnership LLC l Contractor for the U.S. Department of Energy 4021 National Parks Highway l PO Box 2078 l Mail Stop GSA-211 Carlsbad NM 88220 From: Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>
Sent: Tuesday, November 23, 2021 11:15 AM To: Porter, Steve - NWP <steve.porter@wipp.ws>; Burns, Scott - NWP - NTP
<Scott.Burns@wipp.ws>; Sellmer, Todd - NWP <Todd.Sellmer@wipp.ws>
Cc: Allen, William <William.Allen@nrc.gov>
Subject:
FW: ACTION: Review Responses to Questions: TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the HalfPACT Shipping Package Application, Docket No. 71-9279 The message to steve.porter@wipp.ws Scott.Burns@wipp.ws Todd.Sellmer@wipp.ws on Tue Nov 23 2021 11:14:38 contains a file attachment:
Test Acceptance Questions.docx that may have been dropped.
Good afternoon, Attached are additional questions from the shielding reviewer. I will set up a meeting next week to discuss.
Thanks in advance, Norma From: Allen, William <William.Allen@nrc.gov>
Sent: Monday, November 22, 2021 12:57 PM To: Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>; Thomlinson, Aaron
<Aaron.Thomlinson@nrc.gov>; Wise, John <John.Wise@nrc.gov>; Khan-NMSS, Omar
<Omar.Khan2@nrc.gov>
Subject:
RE: ACTION: Review Responses to Questions: TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the HalfPACT Shipping Package Application, Docket No. 71-9279
- Norma, Based on what the applicant provided, the attached Word document has a few questions.
Chris From: Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>
Sent: Monday, November 22, 2021 8:39 AM To: Allen, William <William.Allen@nrc.gov>; Thomlinson, Aaron <Aaron.Thomlinson@nrc.gov>;
Wise, John <John.Wise@nrc.gov>; Khan-NMSS, Omar <Omar.Khan2@nrc.gov>
Subject:
ACTION: Review Responses to Questions: TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the HalfPACT Shipping Package Application, Docket No. 71-9279 Good morning, Please review the attached responses provided by the applicant and let me know if there are additional questions or of the attached responses are acceptable. I will appreciate your response NLT 11/29/21.
Thanks in advance, Norma From: Sellmer, Todd - NWP <Todd.Sellmer@wipp.ws>
Sent: Friday, November 19, 2021 4:23 PM To: Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>; Burns, Scott - NWP - NTP
<Scott.Burns@wipp.ws>; Porter, Steve - NWP <steve.porter@wipp.ws>
Cc: Allen, William <William.Allen@nrc.gov>; Thomlinson, Aaron <Aaron.Thomlinson@nrc.gov>;
Wise, John <John.Wise@nrc.gov>; Khan-NMSS, Omar <Omar.Khan2@nrc.gov>
Subject:
[External_Sender] RE: Revision 25 of the TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the HalfPACT Shipping Package Application, Docket No. 71-9279
- Norma, Please see the attached document with the responses to the questions identified below. It should also be noted that in addition to the responses below, that our fabrication specification for the SCAs go in to much greater detail on the gamma scan requirements. If there are additional questions or information required please contact me at your convenience.
- Regards, Todd Todd Sellmer NWP, Manager, Packaging & Information Systems ASNT Level III / ASNT Fellow Contractor for the U.S. Department of Energy Office Phone (575) 234-7396 Cell Phone (575) 302-7583 From: Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>
Sent: Friday, November 19, 2021 8:29 AM To: Sellmer, Todd - NWP <Todd.Sellmer@wipp.ws>; Burns, Scott - NWP - NTP
<Scott.Burns@wipp.ws>
Cc: Allen, William <William.Allen@nrc.gov>; Thomlinson, Aaron <Aaron.Thomlinson@nrc.gov>;
Wise, John <John.Wise@nrc.gov>; Khan-NMSS, Omar <Omar.Khan2@nrc.gov>
Subject:
Revision 25 of the TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the HalfPACT Shipping Package Application, Docket No. 71-9279 WARNING - EXTERNAL EMAIL This message does not originate from a known WIPP email system.
Use caution if this message contains attachments, links or requests for information.
Good morning, I looked at the page change submitted and it seems to address the type of testing that you will perform. After talking to the staff this week, the staff needs more detailed information about the acceptance criteria for the lead shield and compliance with Part 71. In terms of acceptance criteria, mentioning that the lead shield will meet the criteria in the drawings and using the gamma scan answers a portion of the staffs question. There is additional information related to the acceptance criteria for the lead shield that the staff needs in the application in order to finalize its review. These are questions to reflect a more detailed version of the questions previously provided:
- 1. How do you ensure that the thickness of the lead shield, as specified in Drawing No. 163-001, is met? Are there are any tolerances associated with the thickness of the lead shield? Is it an average of x number of measurements?
- 2. Is the gamma detector calibrated with certain frequency (e.g., every that instrument is used, once a month)? How is it calibrated (e.g., developing a thickness-intensity curve perform a polynomial or linear regression)?
- 3. Is the gamma detector tested prior to using it to ensure that the best possible results are
obtained?
- 4. Besides verifying the lead shields thickness, as part of the acceptance criteria, do you look for voids by measuring the dose rate on the surface of the shielded containers? What is the dose rate acceptance criteria for the shielded container?
- 5. Since, per lasts week phone call, there is no credit taken for the foam that will surround the shielded containers during shipment, how does the dose rate criteria for the shielded container translates into compliance with dose and dose rate requirements in 10 CFR Part 71?
Or do you ensure compliance with 10 CFR regulations by measuring the dose\\dose rates prior and after the shipment of the shielded containers.
I am providing more detailed questions to ensure that there is a clear understanding of the information requested. I will let you know if the staff has additional questions Please call me if you have questions about this email. I have a meeting at 10:30 AM (EST) and should be available from 11:00 AM to 11:30 AM.
Thanks in advance, Norma (301)318-3991 From: Sellmer, Todd - NWP <Todd.Sellmer@wipp.ws>
Sent: Thursday, November 18, 2021 2:52 PM To: Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>; Burns, Scott - NWP - NTP
<Scott.Burns@wipp.ws>
Subject:
[External_Sender] RE: Revision 25 of the TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the HalfPACT Shipping Package Application, Docket No. 71-9279
- Norma, We believe that once your staff reviews the submittal sent today relative to the acceptance criteria for the shielding integrity testing, they will find that we have addressed the bullets below specifically.
If additional discussion is necessary, please contact me via email or at my cell phone number below.
- Regards, Todd Todd Sellmer NWP, Manager, Packaging & Information Systems ASNT Level III / ASNT Fellow Contractor for the U.S. Department of Energy Office Phone (575) 234-7396 Cell Phone (575) 302-7583 From: Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>
Sent: Thursday, November 18, 2021 8:10 AM To: Sellmer, Todd - NWP <Todd.Sellmer@wipp.ws>; Burns, Scott - NWP - NTP
<Scott.Burns@wipp.ws>
Subject:
RE: Revision 25 of the TRUPACT-II Shipping Package Application, Docket No. 71-9218, and Revision 8 of the HalfPACT Shipping Package Application, Docket No. 71-9279 WARNING - EXTERNAL EMAIL This message does not originate from a known WIPP email system.
Use caution if this message contains attachments, links or requests for information.
Good morning, I will provide the information to the staff. The staff met this week and there are some questions that need to be addressed. These questions are the following:
How do you verify that the package meets the minimum thickness of the lead shield as specified in Drawing No 163-010, Revision 0, Note No. 16 of the HalfPACT package?
What is the acceptance criteria to meet 10 CFR Part 71 regulations?
The acceptance criteria for the lead shield, and the answer to these questions, should be incorporated in the acceptance tests chapter related to the lead shielding material, including the information related to using the gamma scans to ensure that the lead shield meets the established criteria for meeting the regulations.
I am available to talk this afternoon about the information requested in this email.
Thanks in advance, Norms From: Morrison, Cindy - NWP <Cindy.Morrison@wipp.ws>
Sent: Thursday, November 18, 2021 9:52 AM To: Foreman, David - CBFO <david.foreman@cbfo.doe.gov>; Princen, Kenneth - FedNet
<kenneth.princen@cbfo.doe.gov>; Smith, DaBrisha - CBFO <DaBrisha.Smith@cbfo.doe.gov>;
Standiford, Daniel (Dan) - FedNet <dan.standiford@cbfo.doe.gov>; Toothman, Mindy - CBFO
<mindy.toothman@cbfo.doe.gov>; Walker, Andy - FedNet <andy.walker@cbfo.doe.gov>; Shuler, James <james.shuler@em.doe.gov>; julia.shenk@em.doe.gov; Gelder, Lawrence (CONTR)
<lawrence.gelder@em.doe.gov>; Garcia Santos, Norma <Norma.GarciaSantos@nrc.gov>; White, Bernie <Bernard.White@nrc.gov>
Cc: Sellmer, Todd - NWP <Todd.Sellmer@wipp.ws>; Burns, Scott - NWP - NTP
<Scott.Burns@wipp.ws>
Subject:
[External_Sender] Revision 25 of the TRUPACT-II Shipping Package Application, Docket No.
71-9218, and Revision 8 of the HalfPACT Shipping Package Application, Docket No. 71-9279
- All, Nuclear Waste Partnership LLC, on behalf of the U.S. Department of Energy, Carlsbad Field Office, has electronically submitted an amendment to application for Revisions 25 and 8 of the TRUPACT-II and HalfPACT shipping packages. The document accession numbers for this submittal are ML21322A121, ML21322A122, ML21322A123, ML21322A124, and ML21322A127. The transmittal letter and summary of revisions for this submittal are attached.
Please feel free to contact Mr. Todd Sellmer (575.302.7583), Mr. Scott Burns (575.706.7920), or me if you have any questions or need anything else.
Thank you, Cindy Morrison Document Control Administrator Cindy Morrison Administrative Specialist Nuclear Waste Partnership LLC Contractor for the U.S. Department of Energy (505) 350-3693 (cell)