L-2022-048, Submittal of Refueling Outage SL2-26 Steam Generator Tube Inspection Report

From kanterella
(Redirected from ML22080A201)
Jump to navigation Jump to search

Submittal of Refueling Outage SL2-26 Steam Generator Tube Inspection Report
ML22080A201
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 03/21/2022
From: Godes W
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2022-048
Download: ML22080A201 (87)


Text

March 21, 2022 Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957 L-2022-048 10 CFR 50.55a 10 CFR 50.36 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington DC 20555-0001 RE: St. Lucie Nuclear Plant, Unit 2 Docket No. 50-389 Refueling Outage SL2-26 Steam Generator Tube Inspection Report Attached is the St. Lucie Unit 2 Technical Specification 6.9.1.12 steam generator tube inspection report for the fall 2021 refueling outage (SL2-26). This submittal is made within 180 days after the initial entry into hot shutdown following the completion of the steam generator inspection that was performed in accordance with TS 6.8.4.l, Steam Generator (SG) Program.

Please contact Tim Falkiewicz at 772-429-3756 should you have any questions regarding this submittal.

Sincerely, Wyatt Godes Regulatory Affairs Manager St. Lucie Nuclear Plant WG/tf

Enclosure:

SL2-26 Steam Generator Tube Inspection Report (86 Pages)

Enclosure SL2-26 Steam Generator Tube Inspection Report

==

Introduction:==

The enclosed Steam Generator (SG) Tube Inspection Report for the St. Lucie Unit 2 recirculating steam generators (RSGs) is submitted for the inspection performed during refueling outage 26 (hereafter referred to as the SL2-26 inspection/outage), as required by Technical Specification section 6.9.1.12. The SL2-26 inspection was performed in accordance with Technical Specification 6.8.4.l.1, and was the seventh (and last) inspection of the RSGs in the first sequential period of 144 EFPMs. References to prior SG Tube Inspection Reports for the RSGs in the first period are tabulated in Appendix A along with a list of acronyms and abbreviations used in this report.

At unit shutdown for the SL2-26 inspection, the RSGs had operated for approximately 11.85 EFPY (142.2 EFPM) since installation in December 2007. This included operation for approximately 1.35 EFPY (16.24 EFPM) and 1.43 EFPY (17.13 EFPM) during the two fuel cycles (cycles 24 and 25) leading-up to the SL2-26 inspection. Initial entry into Hot Shutdown following completion of the SL2-26 inspection was made on September 25, 2021.

St. Lucie Unit 2 is a 2-loop Combustion Engineering designed NSSS with Model 86/19TI RSGs manufactured by AREVA. The RSGs were fabricated using thermally-treated Inconel 690 tubing.

Each RSG contains 8,999 U-tubes; each tube has a nominal OD of 0.75" and a nominal wall thickness of 0.0429". The tubes have a tri-pitch arrangement and are supported by broached, stainless steel tube support plates (TSPs).

A. Scope of Inspections Performed on each SG The SG inspection scope during the SL2-26 outage met the current requirements of the St. Lucie Unit 2 Technical Specifications, the SG Program Guidelines (NEI 97-06 Rev 3) and its referenced EPRI Guidelines. Since the St. Lucie plant has also submitted a License Amendment Request1 to adopt Revised Frequencies for Steam Generator Tube Inspections (TSTF-577), the scope of inspections performed in SL2-26 was selected to also meet TSTF-577 inspection requirements.

Primary-side:

  • 100% full-length bobbin probe examination of all active tubes.
  • Array probe examination at TTS locations of all tubes in hot and cold leg tube expansion transitions of peripheral high-flow regions, and low-row tubes along the tube-free lane. (Peripheral tubes in each RSG span the 2 outermost tubes (of each row) exposed to the annulus, and all tubes in Rows 1-4 along the tube-free lane.) The exam extent was +/- 3.0 from the TTS.
  • Supplemental exam of a 30% tube sample of tight-radius U-bends of Rows 1 & 2 using the array probe. The exam extent was from the uppermost TSP on the hotleg to the uppermost TSP on the cold leg. During the 1st sequential period, all U-bends of rows 1 & 2 were examined using the

+Point' or array probes.

  • Diagnostic +Point' probe exam at special interest locations as required based on the results of the bobbin coil and/or array coil data. In addition, array probe exams were completed of all tubes with previously-identified PLP Indications, and adjacent tubes.
  • Selected wear indications were profiled with line-by-line sizing to provide additional information for condition monitoring and operational assessment purposes.

1

Reference:

Enclosure 2 - Volume 16 - St. Lucie Plant, Units 1 and 2, Improved Technical Specifications Conversion ITS Chapter 5.0 Administrative Controls, Revision 0, NRC ADAMS Accession Number ML21265A301.

ENCLOSURE Page 1 of 86 L-2022-048

  • Visual inspection of all installed tube plugs in each RSG.
  • Visual inspection of all channel head components of each SG per recommended actions in Westinghouse NSAL 12-1 Rev 1 "Steam Generator Channel Head Degradation" October 2017.

Secondary-side:

  • Visual inspection of all accessible components of the Steam Drum/Upper Internals in both SGs.

This included a sample of the primary moisture separator swirl vanes, drains, the loose parts trapping screens, and the feedwater ring and supports in both RSGs.

  • At the TTS, visual exams were conducted of the annulus region, the no-tube lane and select in-bundle columns in both legs after upper bundle flush activities. This was completed during FOSAR after sludge lancing in each SG.

B. Active degradation mechanisms found Wear at tube support locations was the only active (existing) degradation mechanism identified during the SL2-26 RSG inspection. This degradation mechanism was found on tubes at the following tube support locations:

  • Wear at anti-vibration bar (AVB) contact points
  • Wear at V-shaped support pad (V-SSP) contact points2
  • Wear at tube support plate (TSP) contact points No degradation was identified that was due to foreign objects or to corrosion degradation mechanisms. No evidence of tube-to-tube wear was found.

C. Nondestructive examination techniques utilized for each degradation mechanism Table 1 is a list of the EPRI Examination Technique Specification Sheets (ETSS) used for degradation detection/sizing during the SL2-26 inspection.

Table 1 NDE Technique Degradation Mechanism ETSS detection/sizing Location/Description Status Type 1

Bobbin Wear at AVB supports (extended for detection of V-shaped support pad and V-shaped support bar wear)

Existing Volumetric I-96041.1 Rev 6 2

Bobbin Wear at AVB and TSP supports (extended for detection of V-shaped support pad and V-shaped support bar wear)

Existing Volumetric 96004.1 Rev. 13 3

Bobbin Wear at AVB and TSP supports Existing Volumetric 96004.3 Rev. 13 4

Bobbin Foreign Object Wear (PLP)

Potential Volumetric 27091.2 Rev. 2 5

Bobbin Tube-to-tube Wear Potential Volumetric 13091.1 Rev. 0 6

+Point' 13901.1 Rev 1 2 Wear at V-SSPs is also commonly called appui wear. Clarification of V-SSP Wear is documented in the St. Lucie Unit 2 Response to RAIs #10 & 11 (NRC ADAMS Accession No. ML15190A336) on the SL2-21 SG Tube Inspection Report.

ENCLOSURE Page 2 of 86 L-2022-048

NDE Technique Degradation Mechanism ETSS detection/sizing Location/Description Status Type 7

Array3 Wear at broached support plates Existing Volumetric 11956.3 Rev 3, 11956.4 Rev 3 8

+Point' 96910.1 Rev. 11 9

+Point' Wear at AVB supports (extended for detection of V-SSP)

Existing Volumetric 10908.5, Rev. 0 10 Array Wear at AVB Supports Existing Volumetric 17909.1 Rev. 1, 17909.4 Rev. 1 MAPOD App. I 11

+Point' PLP Wear (morphology dependent)4 Potential Volumetric 27901.1 Rev 1, 27902.1 Rev 2, 27903.1 Rev 1, 27904.1 Rev 2, 27905.1 Rev 2, 27906.1 Rev 1, 27907.1 Rev 2 12

+Point' Wear at V-shaped support structure (V-SSP)

Existing Volumetric See footnotes3, 5 13 Array Shape-dependent volumetric indications (freespan; part not present)

Potential Volumetric 17901.1/.3 Rev 0 17902.1/.3 Rev 0 17903.1/.3 Rev 0 17904.1/.3 Rev 0 17905.1/.3 Rev 0 17906.1/.3 Rev 0 D. Location, orientation (if linear), and measured sizes (if available) of service induced indications The actual listing of service-induced indications identified during the SL2-26 inspection is attached in Appendix B thru F of this report, and is grouped according to the index Table below (Table 2).

Unless noted otherwise, each Appendix contains Indications for both SG-2A and SG-2B.

Table 2 - Indexed listing of Indications in Appendix B thru F Description Appendix No. of Pages Bobbin; All TSP Wear B

4

+Point'; Wear at V-shaped support pads (V-SSP)

C 2

Bobbin; AVB U-bend Apex Wear6 (AV4/5, AV3/6)

D 2

Bobbin; AVB Wear 40% TWD E

2 Bobbin; AVB Wear 20-39%, 1-19% TWD F

70 3 Array exam extended for detecting foreign object (FO) wear at the TTS and freespan, and for detecting FOs.

4 ETSS 27905.1 Rev. 1 was first used during SL2-21 to provide supplemental V-SSB wear sizing information. ETSSs 27901.1 thru 27907.1 have been extended for sizing V-SSB wear.

5 Site specific qualification for V-SSP wear per AREVA (proprietary) document 51-9193913, Appui Wear Detection and Sizing Site Qualification.

6 Note: AV4/5 and AV3/6 AVB U-bend Apex wear occur on tubes in Rows 69 and 40, respectively. Additional info on AVB U-bend Apex wear is documented in the St. Lucie Unit 2 Response to RAI #10 in NRC ADAMS document, ML15190A336.

ENCLOSURE Page 3 of 86 L-2022-048

E. Number of tubes plugged during the inspection outage for each active degradation mechanism The number of tubes plugged for each active degradation mechanism is summarized below in Table 3:

Table 3 - Tubes Plugged during SL2-26 inspection outage Reason for Plugging SG 2A SG 2B Total AVB Wear 40% - Tech Spec limit 50 3

53 AVB Wear < 40% - preventive plugging7 9

3 12 AVB U-bend Apex Wear (AV4/5, AV3/6)8 0

0 0

PLP indications - preventive plugging 0

0 0

Wear at V-shaped support pad (V-SSP) 0 0

0 TSP Wear 0

0 0

Total 59 6

65 F. Total number and percentage of tubes plugged to date The total number and percentage of tubes plugged to-date in each SG is summarized below in Table 4:

Table 4 - Cumulative Tube Plugging Summary following the SL2-26 Inspection SG Total Plugged

% Plugged 2A 436 4.84%

2B 52 0.58%

G. The results of condition monitoring, including the results of tube pulls and in-situ testing All SG tubes inspected during the SL2-26 outage satisfied the condition monitoring (CM) requirements for structural and leakage integrity. No evidence of corrosion degradation was found, and no indications were found to exceed structural limits. All wear indications detected (at AVB, V-SSP and TSP locations), met CM requirements. Therefore, no tubes required in-situ pressure testing for either tube burst or leakage based on the SL2-26 inspections. No tube pulls were required.

1. The largest TSP Wear (%TWD) indications were 27% and 29%, in SG-2A and SG-2B, respectively. The largest growth (since the last inspection) of all previously-reported TSP indications was 9% TWD. All detected TSP wear indications fell below the CM limit for burst and leakage. The voltages for all TSP indications that were inspected with +Point' were less than 3.0 volts, confirming the burst and leakage integrity for the tubes and in-situ pressure testing was not required. No tubes were plugged due to TSP Wear. The list of TSP Wear indications identified during SL2-26 is provided in Appendix B.
2. Five (5) previously-identified wear indications were reported during SL2-26 which were associated with V-shaped support pad (V-SSP) locations. Each wear indication was shallow in depth and showed little to no growth since the last inspection. All V-SSP indications were sized with a qualified sizing technique, met the CM margin requirements, and the tubes were returned to service based on a plug-on-NDE sizing approach (See NDE Technique #12 of Table 1). No 7 These additional tubes were selected for preventive plugging based on a chosen criteria. This preventive measure allows for additional margins on wear rates, and to limit the likelihood that CM screening limits would be exceeded during the next scheduled inspection (SL2-29).

8 The SG AVB arrangement for St. Lucie 2 is shown in Figure 2 of document with NRC ADAMS Accession No. ML14279A237.

ENCLOSURE Page 4 of 86 L-2022-048

wear indications were identified on tubes adjacent to V-SSP location (known as v-shaped support bars or V-SSBs). The list of V-SSP indications is provided in Appendix C.

3. During the primary side ECT examinations, no tube degradation was detected at any of the locations where possible loose parts (PLPs) were reported on the secondary-side of the SGs.

None of the PLP signals had associated wear on neighboring tubes as detected using the Array probe and confirmed using the +Point' probe. These tubes remain in service.

4. Previously-identified AVB U-bend Apex wear was detected on some tubes in Row 69 of both SGs using the bobbin probe, and on 1 tube in Row 40 of SG-2A. Row 69 and Row 40 are located just below the AV4/5 and AV3/6 design depth locations, respectively. AVB U-bend Apex wear indications showed little or no growth since the last inspection. The highest recorded indications of AVB U-bend Apex wear (AV4/5) was 34% TWD in SG-2A and 11% TWD in SG-2B. No indication of AVB U-bend Apex Wear met the criteria for preventive plugging. AVB U-bend Apex Wear indications are provided in Appendix D.
5. Fifty (50) tubes in SG-2A and three (3) in SG-2B were reported as having AVB Wear of 40%

TWD or greater. These tubes were plugged based on wear indication depths reaching the plugging limits provided in Technical Specifications. The highest AVB wear indications measured 45% TWD in SG-2A and 42% TWD in SG-2B. The list of AVB Wear indications 40% TWD is provided in Appendix E. To provide added margin on wear rates and to limit the likelihood that the CM screening limits would be exceeded during the next scheduled inspection (SL2-29), 12 additional tubes (9 in SG-2A, 3 in SG-2B) having AVB Wear indications <40%

TWD were selected for preventive plugging based on a developed criteria comprised of indication depths, growth rates and/or number of indications on the tubes. A complete listing of AVB Wear indications (with <40% TWD) is provided in Appendix F. All detected wear at AVB supports met the required integrity margins for CM, whether sized by bobbin or +Point', and AVB wear indications met the CM requirements for burst and leakage.

6. Based on industry operating experience described in Westinghouse NSAL 12-019 Rev 1, visual inspection of the primary-side channel head bowl (in both SGs) was performed in accordance with the recommendations presented in the NSAL. The channel head and tubesheet cladding were also inspected for rust stains and loss of material. All previously-installed tube plugs in the HL and CL were visually inspected during the SL2-26 inspection outage. All plugs were confirmed to be in their correct locations, and showed no visible signs of leakage based on the visual examination. No degradation of the tube plugs, tubesheets, divider plate assemblies or primary-side channel head bowl areas were noted apart from that incurred during a historical foreign object event in SG-2B10. No corrosion-related degradation was identified in any of the SG channel head components.
7. Sludge lancing the TTS after upper bundle flush (UBF), removed 70 and 83.5 lbs. of sludge from SG-2A and SG-2B, respectively. During secondary-side visual exams and FOSAR at the TTS, two (2) foreign objects (FOs) were removed from the CL of SG-2A. One was a light metallic foil-like object; the other was a small metallic piece of wire that measured approximately 2 inches long by 1/16 inch in diameter. Two objects were also removed from SG-2B: one was a small, irregular-shaped metallic object found in the HL; the other was a light, metallic foil-like object found in the CL. A few small sludge rocks were also identified during FOSAR but were not retrieved.
8. During the inspection of the SG Upper Internals/Steam Drum section, the inner support brackets of the SG-2A feedring and the extrados of the feedring at the 270 deg location were found to be slightly deformed from a pressure transient in the feedring during the last operating cycle.

Deformation of the inner support brackets was expected in SG-2A since the water-hammer 9 Westinghouse NSAL-12-1 Rev 1, Steam Generator Channel Head Degradation, October 2, 2017.

10 This event is described in Section G Item #8 of the SL2-22 SG Tube Inspection Report (NRC ADAMS Accession No. ML16111B235).

ENCLOSURE Page 5 of 86 L-2022-048

monitoring criteria established for this phenomenon was met following a unit trip on 1/21/21. All welds of the feedring support system were noted to be intact and no loose parts were generated from the event. Repair ligaments were installed to the support brackets, and the support gaps were restored during repairs. The as-found condition and actions taken on the feedring/supports during SL2-26 were documented in the corrective action program, and the feedring support system was restored to its design condition. No degradation was observed during visual exams of the moisture separator components in the Upper Internals or the loose parts trapping screens.

H. The effective plugging percentage for all plugging in each SG No tube repair methods (such as sleeving) are approved for St. Lucie Unit 2 that would have an effect on the effective plugging percentages. Therefore, the effective plugging percentage for each SG is the same as the Percentage of Tubes Plugged in Item F above.

APPENDIX A - Additional Information References to prior SG Tube Inspection Reports EOC Outage ADAMS Accession No.

EOC-17 SL2-18 (1st ISI)

ML093230226 EOC-18 SL2-19 ML11270A015 EOC-19 SL2-20 ML13141A479 EOC-20 SL2-21 ML14279A237 EOC-21 SL2-22 ML16111B235 EOC-22 SL2-23 ML17257A080 EOC-23 SL2-24 ML19081A146 Abbreviations and Acronyms AVB Anti-Vibration Bar OD Outside Diameter CL Cold Leg PLP Possible Loose Part CM Condition Monitoring PWSCC Primary Water Stress Corrosion Cracking EOC-25 End-of-cycle 23 (SL2-26 inspection)

RSG Recirculating Steam Generator EFPM Effective Full Power Months SG Steam Generator EFPY Effective Full Power Years SSI Secondary Side Inspection EPRI Electric Power Research Institute TSP Tube Support Plate ETSS Exam Technique Specification Sheet TTS Top of Tubesheet FO Foreign Object TWD Through Wall Depth HL Hot Leg V-SSB V-Shaped Support Bar wear (side bar wear)

ISI In-service Inspection V-SSP V-Shaped Support Pad wear (appui wear)

MAPOD Model-assisted probability of detection WAR Mechanical Wear ENCLOSURE Page 6 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:04:56 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 1 of 1 SL2 09/21 Bobbin TSP Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 1 2 0.26 13 04C +0.32 0.24 12 04H -0.74 1 52 0.16 9 05C +0.30 1 60 0.20 11 04C +0.39 1 62 0.33 16 04C +0.37 1 80 0.19 11 06C -0.76 1 82 0.18 10 05C +0.32 0.17 10 05C -0.67 1 86 0.30 15 05C +0.25 0.15 9 05C -0.72 0.32 16 04C +0.25 0.21 11 04C -0.69 1 92 0.20 11 04C +0.25 0.16 9 02C -0.60 1 96 0.14 8 02C +0.32 1 140 0.09 6 06C -0.74 0.15 9 05C -0.70 0.26 14 04C +0.30 0.28 15 04C -0.65 1 154 0.22 12 05C +0.35 0.31 16 05C -0.74 0.18 11 04C +0.35 1 156 0.17 10 04C +0.28 1 160 0.36 18 05C -0.79 0.32 16 04C -0.64 1 162 0.25 14 05C -0.76 1 168 0.16 10 05C +0.33 0.32 16 05C -0.65 0.25 13 04C -0.71 2 1 0.13 8 05C +0.34 0.26 13 05C -0.62 0.26 13 04C +0.37 0.11 6 06H -0.74 2 5 0.12 7 04C -0.62 2 61 0.18 10 04C +0.35 0.12 7 02C +0.39 2 91 0.18 10 04C -0.74 2 97 0.16 9 02C +0.37 2 121 0.21 12 04C +0.23 3 2 0.12 11 04H -0.74 3 8 0.13 12 04H -0.74 0.08 8 04H +0.37 3 158 0.18 11 05C -0.65 3 168 0.12 8 05C +0.40 0.16 9 05C -0.76 0.26 14 04C +0.39 4 5 0.17 9 04C +0.42 4 73 0.09 6 04C +0.40 4 143 0.10 6 04C -0.65 4 151 0.10 6 04C -0.72 5 58 0.15 9 04C -0.72 5 82 0.09 5 03H +0.32 5 164 0.18 10 05C +0.37 0.14 9 05C -0.74 5 168 0.19 11 05C -0.74 6 7 0.08 6 04C +0.39 6 9 0.17 9 04H -0.76 6 169 0.10 7 04C -0.62 7 2 0.13 9 04C +0.42 7 92 0.10 7 04C +0.35 0.10 7 01C +0.30 10 1 0.06 5 04H -0.65 10 3 0.12 9 04C -0.71 10 9 0.11 7 04H +0.51 12 141 0.12 9 04C -0.74 13 2 0.08 5 04H -0.51 14 13 0.11 8 04H -0.69 14 167 0.10 6 05C -0.66 15 168 0.14 11 05H +0.25 17 2 0.16 9 04H +0.51 18 91 0.12 8 03C -0.63 23 58 0.14 10 04C +0.35 30 9 0.11 6 05C -0.65 30 17 0.12 8 03H -0.58 31 66 0.08 5 02C +0.42 35 118 0.08 6 02H -0.23 37 6 0.08 5 04C +0.42 47 162 0.10 8 05C +0.48 48 9 0.12 6 04C +0.39 53 158 0.16 8 05C +0.46 53 162 0.13 10 05C +0.46 54 159 0.11 6 05C +0.46 55 14 0.10 6 04H -0.62 57 10 0.10 5 04C +0.42 57 14 0.10 6 04H -0.65 58 157 0.12 6 05C +0.44 59 160 0.13 7 05C +0.46 60 157 0.14 8 05C -0.69 60 159 0.11 9 05C +0.49 61 152 0.16 12 05C +0.44 62 85 0.07 5 03H -0.65 63 156 0.13 7 05C -0.65 64 157 0.18 9 05C +0.46 67 156 0.16 9 05C +0.47 68 157 0.15 8 05C -0.69 69 16 0.12 6 05H +0.44 70 151 0.17 12 05C +0.47 72 155 0.19 11 05C +0.45 73 18 0.13 8 04H -0.51 74 71 0.28 16 07C +0.09 75 22 0.18 12 04H -0.56 77 18 0.12 9 04H +0.44 77 20 0.23 12 04H -0.63 79 22 0.09 5 04H -0.72 79 26 0.09 6 04H -0.65 79 130 0.15 9 04C +0.37 80 17 0.17 10 04H -0.53 81 18 0.19 11 04H -0.51 0.32 16 04H +0.44 0.15 9 05H -0.56 86 21 0.30 16 04H -0.60 0.13 8 05H -0.53 87 26 0.12 9 04H -0.65 87 28 0.12 10 06H -0.74 88 25 0.21 13 04H -0.56 0.33 18 04H +0.49 89 22 0.10 6 04H -0.54 0.35 17 04H +0.44 90 23 0.10 6 04H -0.56 90 33 0.18 9 04H -0.65 0.11 6 05H -0.56 92 25 0.14 11 04H +0.39 92 27 0.16 12 04H +0.41 92 29 0.10 6 04H +0.42 93 26 0.13 8 04H -0.67 93 34 0.12 7 04H -0.70 94 31 0.13 10 04H +0.44 94 37 0.14 10 04H -0.78 94 141 0.13 9 03H +0.37 95 36 0.16 12 04H -0.80 96 27 0.09 7 07H -0.76 96 29 0.21 11 04H -0.72 96 31 0.10 6 04H -0.74 98 143 0.12 7 07H -0.76 99 28 0.20 11 04H +0.39 0.15 9 04H -0.74 99 30 0.10 8 04H -0.76 100 29 0.10 6 06H -0.70 100 31 0.15 9 05H -0.69 102 39 0.09 5 04H +0.42 0.18 9 04H -0.77 103 32 0.18 13 04H +0.42 0.15 11 04H -0.81 103 42 0.10 5 04H +0.39 106 43 0.11 6 04H -0.76 106 45 0.14 8 04H -0.79 108 39 0.19 10 04H -0.76 108 111 0.11 7 03C -0.55 109 34 0.30 15 04H +0.37 0.18 10 04H -0.74 109 40 0.20 10 04H -0.79 109 42 0.09 5 07C -0.68 110 39 0.15 8 04H +0.37 110 43 0.09 5 04H -0.79 111 36 0.11 6 07H +0.32 0.21 11 07H -0.67 0.22 12 04H -0.77 111 38 0.16 12 04H +0.37 111 134 0.18 9 04C -0.62 0.11 6 05C +0.49 113 38 0.14 8 04H -0.74 116 41 0.15 11 04H -0.76 117 42 0.11 6 04H +0.37 117 128 0.10 6 03C -0.53 119 42 0.16 9 05H -0.62 0.18 10 04H -0.76 119 44 0.14 7 05H -0.67 120 45 0.16 8 04H +0.37 120 111 0.12 7 05C +0.44 121 124 0.16 9 05C -0.58 122 45 0.09 5 04H +0.42 0.12 7 04H -0.77 122 47 0.11 6 05H -0.70 124 49 0.16 9 04H -0.65 127 100 0.12 6 05C +0.49 129 96 0.20 12 05C +0.46 129 114 0.14 8 06H -0.77 130 57 0.11 6 04H -0.62 131 92 0.17 10 05C +0.48 131 104 0.09 7 04C +0.50 131 108 0.08 7 03C +0.51 131 110 0.10 6 03C +0.48 0.11 7 05C -0.58 0.15 9 05H +0.35 0.12 7 04H +0.40 133 106 0.12 6 05C +0.53 134 103 0.11 6 06H +0.38 0.26 13 05H +0.40 134 105 0.19 10 05H +0.35 135 78 0.16 8 04C -0.48 138 83 0.19 10 05H +0.30 Total Tubes : 149 Total Records: 191 Appendix B - Wear at TSP ENCLOSURE Page 7 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:05:54 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 1 of 1 SL2 09/21 Bobbin TSP Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 1 168 0.51 22 04C +0.37 2 1 0.78 27 04C -0.62 2 7 0.57 23 04C -0.65 Total Tubes : 3 Total Records: 3 Appendix B - Wear at TSP ENCLOSURE Page 8 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:07:19 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 1 of 1 SL2 09/21 Bobbin TSP Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 1 32 0.16 10 04C -0.60 1 56 0.31 17 05C -0.51 1 70 0.19 12 05C -0.62 1 72 0.15 10 05C +0.30 1 76 0.17 11 05C +0.19 0.12 8 05C -0.67 1 78 0.16 10 05C +0.19 1 82 0.28 16 04C +0.19 0.10 7 04C -0.74 0.30 17 06C -0.32 1 84 0.28 16 04C -0.16 1 110 0.12 8 04C -0.74 1 126 0.14 9 04C -0.60 1 142 0.29 16 05C -0.28 1 148 0.24 14 05C -0.65 1 154 0.19 11 05C +0.30 0.21 13 04C -0.23 1 166 0.22 14 06C +0.28 1 168 0.27 16 04C +0.28 0.12 9 05H -0.74 2 7 0.12 8 06C -0.62 0.26 15 05C +0.12 2 9 0.17 11 04C +0.32 0.14 9 04C -0.62 2 21 0.15 10 05C +0.30 2 63 0.21 13 04C +0.35 0.28 16 04C -0.70 0.12 8 03C +0.37 2 69 0.20 12 04C -0.53 2 75 0.15 10 02C +0.39 2 89 0.13 9 05C -0.65 2 91 0.17 11 05C +0.19 0.13 9 05C -0.67 2 95 0.08 6 05C -0.60 2 111 0.11 7 05C -0.79 2 113 0.08 6 05C -0.65 2 115 0.20 13 05C +0.16 2 125 0.11 8 05C +0.32 2 157 0.20 12 04C +0.32 2 159 0.13 8 04C +0.39 2 169 0.14 10 06C +0.32 0.21 14 05C +0.21 3 30 0.10 7 05C -0.65 3 40 0.18 11 04C +0.23 3 46 0.20 12 04C +0.19 3 52 0.22 13 05C -0.23 3 60 0.16 10 05C +0.28 0.19 12 05C -0.63 0.26 15 04C +0.32 0.17 11 04C -0.62 3 70 0.14 9 04C +0.37 3 82 0.13 8 05C +0.32 3 168 0.12 9 04C +0.32 0.23 15 03C -0.62 4 45 0.29 17 05C +0.18 4 57 0.26 15 05C +0.19 4 71 0.15 10 05C +0.32 5 76 0.14 10 05C +0.28 10 53 0.24 15 05H +0.44 11 80 0.17 10 04C +0.39 16 3 0.13 8 04H +0.51 17 36 0.12 7 05C +0.35 17 82 0.11 7 05C +0.35 18 167 0.14 9 05H -0.65 20 17 0.16 10 04H +0.48 20 167 0.16 14 05H -0.69 22 45 0.17 11 04H -0.66 0.24 15 04C -0.79 22 85 0.13 9 01C -0.58 22 125 0.14 9 03C -0.74 31 10 0.17 11 04C -0.70 36 5 0.17 10 04C -0.61 39 8 0.14 8 04C -0.72 42 7 0.18 10 04C -0.68 44 7 0.19 12 04C -0.70 44 15 0.11 7 04C +0.37 45 8 0.15 9 04C -0.67 51 20 0.11 7 04H +0.44 54 13 0.17 10 04C -0.60 55 160 0.12 8 04H -0.64 0.11 7 05H -0.53 60 159 0.15 10 04H +0.42 61 12 0.14 9 04C -0.67 61 160 0.17 11 05C +0.37 66 153 0.18 11 05C +0.35 67 14 0.21 13 04C -0.63 68 19 0.18 11 07C -0.85 0.19 12 03C -0.70 68 151 0.10 9 05H -0.65 70 13 0.16 10 05C +0.26 0.12 8 04C +0.39 0.17 10 04C -0.63 72 19 0.10 7 07C -0.79 74 15 0.12 8 05C -0.72 75 18 0.14 10 05C +0.21 75 72 0.16 11 04H -0.67 77 152 0.16 14 05C +0.35 78 19 0.22 13 07C -0.83 81 152 0.22 13 04H +0.46 0.17 11 05H +0.42 86 21 0.28 16 04H +0.44 86 27 0.11 8 04H +0.44 86 141 0.12 7 05C +0.32 87 22 0.10 6 04H +0.44 89 144 0.15 10 03C -0.60 91 70 0.15 9 07C -0.66 93 146 0.13 8 05H -0.77 99 142 0.09 6 05C -0.66 0.15 9 06C +0.33 0.15 8 05H -0.72 100 141 0.13 7 05H -0.70 104 139 0.11 7 06C -0.68 105 138 0.07 4 05H +0.48 106 33 0.10 6 04H -0.74 107 60 0.09 6 05C +0.46 107 62 0.12 8 05C -0.69 108 137 0.08 5 04C -0.63 0.16 9 05C -0.63 0.06 4 05C +0.47 109 56 0.13 9 07C -0.72 112 37 0.13 7 04H -0.67 113 54 0.11 7 05C -0.71 113 60 0.06 4 05C +0.49 114 45 0.07 5 04C +0.51 115 56 0.06 4 06C +0.42 116 131 0.28 14 05C -0.58 117 50 0.14 8 04H -0.74 118 41 0.16 10 06C +0.39 0.13 8 04H -0.69 120 127 0.08 5 04C +0.51 121 46 0.12 7 06C +0.39 121 48 0.11 7 05C -0.62 121 126 0.21 11 04C -0.58 122 51 0.23 13 06C -0.70 122 107 0.13 7 04C -0.63 123 46 0.14 8 05C -0.62 0.10 6 04H -0.74 123 50 0.18 10 06C -0.69 0.15 9 06C +0.42 124 51 0.21 13 06C -0.69 0.13 8 04H -0.69 124 55 0.14 8 05C -0.64 124 57 0.09 6 05C -0.69 124 101 0.14 8 04C -0.60 124 103 0.09 6 04C -0.65 125 54 0.17 11 06C -0.67 125 68 0.06 4 05C +0.37 126 51 0.08 5 04H -0.76 126 75 0.16 9 03C -0.61 126 113 0.07 5 04H +0.37 127 58 0.11 7 06C -0.71 127 70 0.11 7 03C -0.66 128 63 0.17 10 03C -0.61 128 73 0.09 6 04H +0.35 129 78 0.13 7 03C -0.59 129 104 0.13 7 04C -0.58 130 57 0.11 7 07H +0.25 130 63 0.13 9 04H +0.35 130 67 0.08 5 05C +0.46 0.20 11 07C -0.67 130 99 0.27 13 04C -0.62 130 103 0.14 7 04H -0.72 131 68 0.10 6 05C +0.44 0.07 5 06C +0.42 131 82 0.15 8 03C -0.62 131 96 0.16 9 04C -0.65 131 98 0.13 8 06C +0.37 131 106 0.06 4 04H +0.32 133 66 0.13 8 07C -0.72 133 76 0.10 6 05C +0.44 133 92 0.13 7 04C -0.65 133 102 0.08 5 04H +0.35 0.18 10 04H -0.72 133 106 0.10 6 04C -0.62 133 108 0.07 4 04H +0.65 134 65 0.07 5 05C +0.46 0.14 9 07H +0.30 134 71 0.10 6 06C +0.32 134 83 0.15 8 03C -0.57 134 89 0.06 4 04H +0.32 134 91 0.17 10 07C +0.26 135 70 0.17 10 05C +0.46 0.11 7 06C +0.42 135 74 0.10 6 04H +0.37 136 71 0.14 9 05C +0.32 136 73 0.13 8 05C +0.44 136 77 0.17 9 03C -0.59 0.08 5 05C +0.44 0.10 7 04H +0.51 136 91 0.15 8 04C -0.62 137 82 0.25 14 07C +0.35 137 92 0.06 4 04C +0.44 138 73 0.07 5 05C +0.44 0.17 10 04H +0.35 138 79 0.18 9 03C -0.54 0.08 5 05C +0.46 138 81 0.11 6 03C -0.61 139 86 0.12 7 06C -0.70 0.14 9 06C +0.40 Total Tubes : 160 Total Records: 199 Appendix B - Wear at TSP ENCLOSURE Page 9 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:06:54 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 1 of 1 SL2 09/21 Bobbin TSP Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 1 82 0.65 28 05C +0.21 0.57 26 05C -0.67 1 84 0.46 23 05C +0.21 1 116 0.56 26 05C -0.26 1 168 0.66 29 05C -0.18 Total Tubes : 4 Total Records: 5 Appendix B - Wear at TSP ENCLOSURE Page 10 of 86 L-2022-048

Framatome Inc 09/11/21 15:35:42 Customer: FPL Plant: St. Lucie Unit: 2 Component: S/G A Page 1 of 1 SL2 09/21 Tubes with VPAD (V-SSB/V-SSP) Wear Indications QUERY: QueryM2[1].qry ROW COL VOLTS DEG CHAN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 UTIL 3 CAL LEG PROBE IDX

====================================================================================

120 43 0.13 102 P1 NQI AV7 +23.08 TEC TEH REV V-SSP 21 HOT 610HS I006 0.13 77 P7 WAR AV7 +23.57 07C AV6 17 ARQUAL 53 COLD 5601P I007 121 44 NDF AV6 -1.00 07C AV6 53 COLD 5601P I008 0.14 142 P1 DSS AV6 -1.00 TEC TEH REV V-SSB 19 HOT 610HS I254 135 102 0.14 90 P7 WAR AV3 +0.96 AV3 AV3 18 ARVQUAL 36 HOT 5601P I009 0.13 129 P1 NQI AV3 +1.05 TEC TEH REV V-SSP 11 HOT 610HS I047 Total Tubes : 3 Total Records: 6 Appendix C - Wear at V-SSP Note: the UTIL 1 entries contains the %TWD values for V-SSP wear indications.

ENCLOSURE Page 11 of 86 L-2022-048

Framatome Inc 09/11/21 15:34:52 Customer: FPL Plant: St. Lucie Unit: 2 Component: S/G B Page 1 of 1 SL2 09/21 Tubes with VPAD (V-SSB/V-SSP) Wear Indications QUERY: QueryM2[1].qry ROW COL VOLTS DEG CHAN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 UTIL 3 CAL LEG PROBE IDX

====================================================================================

73 14 0.15 94 P7 WAR AV2 +1.63 AV2 AV2 18 ARVQUAL 32 HOT 5601P I017 0.12 95 P1 NQI AV2 +1.70 TEH TEC REV V-SSP 25 COLD 610HS I154 110 135 0.23 262 P7 WAR AV8 -1.76 AV8 AV8 24 ARVQUAL 46 COLD 5601P I018 0.19 106 P1 NQI AV8 -1.35 TEC TEH REV V-SSP 12 HOT 610HS I068 112 133 0.26 120 P1 NQI AV7 +21.99 TEC TEH REV V-SSP 12 HOT 610HS I079 0.25 266 P7 WAR AV7 +22.40 AV8 AV7 26 ARVQUAL 46 COLD 5601P I019 Total Tubes : 3 Total Records: 6 Appendix C - Wear at V-SSP ENCLOSURE Page 12 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:09:20 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 1 of 1 SL2 09/21 Bobbin AVB Wear in AVB Transition Row Tubes (Crossover Tube Locations Row 17 @AV2, Row 40 @AV3 and Row 69 @AV4)

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 40 145 0.18 6 AV3 +1.08 69 74 0.52 13 AV4 +0.95 69 98 0.71 13 AV4 +0.45 69 100 1.20 23 AV4 +0.59 69 102 1.88 32 AV4 +1.22 69 104 0.86 21 AV4 +1.14 69 106 2.21 34 AV4 +1.04 69 108 2.15 34 AV4 +1.02 69 110 0.56 16 AV4 +0.87 69 112 0.97 22 AV4 +0.85 69 114 0.39 12 AV4 +0.02 69 116 0.12 4 AV4 +0.65 69 118 0.25 8 AV4 +0.91 69 120 0.26 8 AV4 +1.07 69 122 0.23 7 AV4 +0.25 69 124 0.17 5 AV4 +0.83 69 126 0.15 4 AV4 +0.90 69 128 0.15 4 AV4 +0.91 69 130 0.20 7 AV4 +0.02 69 132 0.13 5 AV4 -0.08 69 136 0.21 7 AV4 +0.70 69 138 0.26 8 AV4 +0.74 69 144 0.27 10 AV4 +0.13 Total Tubes : 23 Total Records: 23 Appendix D - Wear at AVB U-bend Apex ENCLOSURE Page 13 of 86 L-2022-048

Framatome Inc.

09/11/21 15:34:52 Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 1 of 1 SL2 09/21 Bobbin AVB Wear in AVB Transition Row Tubes (Crossover Tube Locations Row 17 @AV2, Row 40 @AV3 and Row 69 @AV4)

ROW COL %TW LOCATION ROW COL %TW LOCATION ROW COL %TW LOCATION 69 18 9 AV4 +0.90 69 20 8 AV4 +0.75 69 24 8 AV4 +0.95 69 36 6 AV4 +0.97 69 44 7 AV4 +0.73 69 46 5 AV4 +0.98 69 52 5 AV4 +0.96 69 56 8 AV4 +1.02 69 62 10 AV4 +1.07 69 78 11 AV4 +1.30 69 84 6 AV4 +0.95 69 92 8 AV4 +0.09 69 98 8 AV4 +0.07 Total Tubes : 13 Total Records: 13 Appendix D - Wear at AVB U-bend Apex ENCLOSURE Page 14 of 86 L-2022-048

Framatome Inc.

9/11/2021 15:35:42 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 1 of 1 SL2 09/21 Bobbin AVB Wear 40-100%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 74 71 3.45 41 AV6 +0.02 3.64 41 AV7 +0.02 77 104 3.37 40 AV6 +0.02 77 116 3.43 41 AV5 +0.02 78 89 3.19 40 AV5 +0.05 78 97 3.85 42 AV5 +0.07 79 74 3.19 40 AV6 +0.02 80 101 3.91 42 AV5 +0.02 81 102 3.39 41 AV6 +0.02 82 85 3.33 40 AV6 +0.02 82 93 3.53 41 AV6 +0.02 82 95 3.46 41 AV5 +0.02 82 99 3.92 42 AV5 +0.02 84 69 3.16 40 AV5 +0.09 84 87 3.22 40 AV4 +0.03 3.27 40 AV5 +0.02 86 101 3.39 41 AV5 +0.05 4.36 44 AV6 +0.07 87 90 3.30 40 AV5 +0.05 90 97 3.98 43 AV5 +0.05 91 80 3.26 40 AV6 +0.00 91 96 4.60 45 AV5 +0.02 91 98 3.46 41 AV5 +0.07 92 79 4.06 43 AV7 +0.00 4.59 45 AV6 +0.00 93 104 3.57 41 AV6 +0.00 3.47 41 AV5 -0.03 95 88 3.45 41 AV5 +0.00 95 96 3.16 40 AV5 +0.00 95 100 3.62 41 AV6 +0.02 96 75 3.23 40 AV7 +0.00 96 79 4.56 45 AV6 +0.00 3.50 41 AV5 +0.02 96 91 3.27 40 AV5 +0.02 97 74 3.44 41 AV6 +0.07 98 73 3.33 40 AV6 +0.00 3.94 43 AV5 +0.00 98 77 3.16 40 AV5 -0.03 99 78 3.18 40 AV7 +0.00 100 73 3.42 41 AV7 -0.02 100 79 3.36 40 AV5 +0.00 104 75 4.00 43 AV5 +0.02 106 73 3.47 41 AV7 +0.02 106 95 3.15 40 AV6 +0.02 3.51 41 AV5 +0.00 108 71 3.52 41 AV5 +0.05 108 99 3.92 43 AV4 -0.02 109 100 3.48 41 AV6 +0.05 112 79 3.37 40 AV6 +0.00 123 72 4.30 44 AV6 -0.02 125 90 4.02 43 AV6 +0.02 127 88 3.74 42 AV6 -0.02 127 90 3.62 41 AV5 +0.00 130 79 3.88 42 AV6 +0.10 135 78 4.31 44 AV5 +0.02 135 92 3.65 42 AV7 +0.09 136 93 3.61 41 AV5 +0.02 137 84 3.19 40 AV5 -0.03 Total Tubes : 50 Total Records: 58 Appendix E - Wear at AVB (40% or more)

ENCLOSURE Page 15 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:10:17 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 1 of 1 SL2 09/21 Bobbin AVB Wear 40-100%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 97 76 3.69 42 AV5 +0.00 108 99 3.37 40 AV5 +0.00 130 67 3.28 40 AV6 +0.02 Total Tubes : 3 Total Records: 3 Appendix E - Wear at AVB (40% or more)

ENCLOSURE Page 16 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 1 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 24 167 0.14 7 AV7 +0.27 25 166 0.28 11 AV7 +0.22 26 19 0.07 4 AV1 +0.00 27 4 0.16 8 AV7 +0.32 27 164 0.15 7 AV7 -0.32 29 4 0.12 6 AV2 -0.30 0.14 7 AV7 +0.32 29 6 0.18 9 AV8 -0.17 29 166 0.13 7 AV7 +0.32 30 5 0.12 6 AV2 -0.28 31 164 0.10 6 AV7 +0.28 31 166 0.27 11 AV7 +0.25 0.18 8 AV2 -0.31 0.12 6 AV1 -0.18 32 163 0.15 8 AV7 -0.29 33 6 0.17 8 AV2 -0.23 0.28 12 AV7 +0.25 0.15 8 AV8 -0.18 33 8 0.16 8 AV2 +0.23 33 162 0.11 6 AV2 -0.20 33 164 0.23 10 AV7 +0.21 0.31 12 AV2 -0.23 34 5 0.21 9 AV7 +0.28 34 7 0.16 8 AV7 +0.23 34 163 0.10 6 AV7 -0.05 0.16 8 AV2 -0.20 34 165 0.18 9 AV7 +0.21 35 6 0.19 9 AV7 -0.30 35 8 0.14 7 AV7 +0.21 35 162 0.11 6 AV2 +0.21 35 164 0.22 10 AV7 +0.24 36 7 0.16 8 AV2 -0.24 0.17 8 AV7 +0.25 36 161 0.11 6 AV7 +0.14 36 163 0.13 7 AV2 -0.27 36 165 0.14 7 AV7 +0.23 37 6 0.21 9 AV7 +0.28 37 8 0.26 11 AV7 +0.21 37 158 0.19 9 AV7 -0.25 37 162 0.11 6 AV8 +0.14 0.16 8 AV7 +0.23 0.12 6 AV7 -0.31 0.12 6 AV2 -0.02 37 164 0.12 6 AV7 -0.28 38 5 0.19 9 AV7 +0.28 38 7 0.11 6 AV2 -0.25 0.26 11 AV7 +0.23 38 9 0.12 6 AV1 +0.22 0.12 6 AV2 -0.24 0.10 6 AV7 -0.26 0.16 8 AV8 -0.18 38 11 0.10 6 AV2 -0.18 0.10 6 AV7 -0.26 38 161 0.21 9 AV7 -0.28 0.14 7 AV2 +0.23 38 163 0.18 8 AV7 +0.24 0.20 9 AV2 -0.26 38 165 0.30 12 AV7 +0.21 0.12 6 AV1 -0.23 39 6 0.29 12 AV2 -0.21 0.23 10 AV7 +0.25 39 8 0.22 10 AV7 +0.23 39 10 0.18 9 AV7 +0.18 39 162 0.24 10 AV7 +0.19 0.13 7 AV2 -0.23 39 164 0.27 11 AV7 +0.23 0.26 11 AV2 +0.18 40 7 0.21 9 AV2 -0.23 0.28 12 AV7 +0.23 40 9 0.56 18 AV7 -0.21 0.31 12 AV8 -0.18 40 11 0.19 9 AV7 -0.21 40 145 0.18 6 AV3 +1.08 40 161 0.15 8 AV7 -0.22 40 163 0.15 7 AV1 +0.18 41 6 0.22 10 AV7 -0.24 41 8 0.08 5 AV7 +0.22 0.16 8 AV8 -0.20 0.16 8 AV2 -0.18 41 158 0.16 8 AV8 +0.18 0.18 8 AV7 -0.18 41 162 0.43 15 AV2 +0.15 41 164 0.22 10 AV7 -0.21 0.21 9 AV2 -0.23 42 7 0.31 12 AV7 -0.20 0.18 8 AV8 -0.18 42 9 0.16 8 AV2 -0.23 0.13 7 AV3 -0.36 0.43 15 AV7 -0.19 42 159 0.19 9 AV7 -0.23 42 161 0.16 8 AV8 -0.21 0.26 11 AV7 -0.21 0.45 16 AV6 +0.37 0.12 6 AV7 +0.23 42 163 0.15 7 AV8 -0.21 0.29 12 AV7 -0.23 0.33 13 AV2 +0.19 43 6 0.10 6 AV2 +0.22 0.11 6 AV3 -0.29 0.14 7 AV6 +0.30 0.35 14 AV7 -0.24 0.22 10 AV7 +0.25 0.12 6 AV8 +0.25 43 8 0.13 7 AV1 +0.22 0.13 7 AV6 +0.30 0.19 9 AV7 +0.23 43 124 0.09 5 AV2 -0.14 43 154 0.13 7 AV6 +0.27 0.24 10 AV3 -0.29 43 158 0.12 6 AV6 +0.28 43 160 0.12 6 AV1 +0.18 43 162 0.10 5 AV7 +0.18 0.21 9 AV6 +0.32 43 164 0.16 8 AV7 +0.23 0.17 8 AV6 +0.28 0.10 5 AV2 -0.28 44 7 0.09 5 AV1 -0.22 0.14 7 AV2 -0.24 0.26 11 AV3 -0.20 0.31 12 AV6 +0.26 0.20 9 AV7 +0.02 44 9 0.15 7 AV2 -0.23 0.13 7 AV3 -0.27 0.10 5 AV6 +0.28 0.21 9 AV8 -0.16 44 11 0.08 5 AV2 -0.23 0.10 6 AV8 -0.16 44 141 0.15 7 AV6 -0.33 44 153 0.18 8 AV6 -0.52 44 157 0.21 10 AV7 -0.22 44 159 0.16 8 AV7 -0.20 44 161 0.34 13 AV6 +0.22 0.17 8 AV6 -0.47 44 163 0.21 10 AV8 -0.21 0.24 10 AV6 +0.20 0.17 8 AV6 -0.44 0.18 9 AV2 +0.20 0.13 7 AV1 -0.23 45 8 0.08 5 AV2 -0.23 0.13 7 AV6 +0.22 0.18 8 AV7 +0.25 45 12 0.12 6 AV2 -0.18 45 14 0.07 4 AV3 -0.20 45 120 0.09 5 AV3 -0.20 45 130 0.14 7 AV6 +0.22 45 142 0.19 9 AV6 +0.20 45 154 0.20 9 AV6 +0.22 0.40 15 AV3 -0.25 45 156 0.12 6 AV7 +0.29 0.14 7 AV6 +0.20 45 158 0.17 8 AV8 +0.16 0.19 9 AV6 +0.18 45 160 0.15 7 AV7 +0.16 0.14 7 AV2 -0.21 45 162 0.18 8 AV8 -0.26 0.14 7 AV7 +0.19 0.29 12 AV6 +0.23 0.11 6 AV3 -0.23 0.22 10 AV2 -0.18 0.12 6 AV1 -0.23 46 7 0.16 8 AV3 -0.23 0.29 12 AV7 +0.23 46 9 0.11 6 AV2 -0.22 0.26 11 AV6 +0.22 46 11 0.25 11 AV2 -0.17 0.19 9 AV3 -0.25 0.18 8 AV6 +0.16 0.19 9 AV7 +0.18 46 13 0.11 6 AV2 -0.15 46 35 0.09 5 AV3 +0.35 46 141 0.18 9 AV6 -0.28 46 157 0.16 8 AV6 -0.32 0.10 5 AV1 -0.16 46 159 0.19 9 AV7 +0.23 0.13 7 AV6 +0.18 46 161 0.18 9 AV7 +0.21 0.49 17 AV6 +0.18 0.25 11 AV2 -0.18 46 163 0.16 8 AV8 +0.22 0.35 14 AV7 +0.26 0.19 9 AV6 +0.18 0.15 7 AV2 -0.23 47 8 0.10 6 AV2 +0.05 0.21 10 AV3 -0.23 0.37 14 AV6 +0.20 0.30 12 AV7 +0.21 0.12 6 AV8 +0.21 47 10 0.19 9 AV7 +0.18 47 12 0.13 7 AV8 +0.23 47 44 0.15 7 AV3 -0.21 47 142 0.15 7 AV6 +0.22 47 154 0.19 9 AV6 +0.18 0.53 18 AV3 -0.27 47 160 0.18 9 AV8 -0.21 0.14 7 AV7 +0.26 0.16 8 AV6 +0.13 0.27 11 AV2 -0.20 0.16 8 AV1 +0.20 47 162 0.27 11 AV8 -0.23 0.31 12 AV7 -0.25 0.57 18 AV6 +0.21 0.18 8 AV3 -0.20 0.23 10 AV2 -0.23 48 7 0.24 10 AV3 -0.21 0.37 14 AV6 +0.20 0.18 8 AV7 +0.23 48 9 0.17 8 AV7 +0.23 0.17 8 AV8 +0.20 0.23 10 AV2 -0.23 0.24 11 AV3 -0.20 0.29 12 AV6 +0.22 48 11 0.15 7 AV2 -0.18 0.27 11 AV7 +0.23 48 13 0.17 8 AV2 -0.14 0.15 7 AV3 +0.14 48 15 0.14 7 AV3 -0.20 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 17 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 2 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 48 35 0.22 10 AV3 +0.29 48 141 0.14 7 AV6 -0.29 48 147 0.24 10 AV6 -0.03 48 153 0.12 6 AV6 -0.36 48 157 0.10 6 AV6 +0.16 48 159 0.16 8 AV7 +0.16 0.17 8 AV3 +0.23 48 161 0.30 12 AV7 +0.18 0.56 18 AV6 +0.25 0.38 14 AV2 -0.14 0.10 6 AV1 +0.21 48 163 0.25 11 AV7 -0.25 0.21 9 AV3 +0.36 0.18 8 AV2 -0.20 49 8 0.12 6 AV2 -0.25 0.22 10 AV3 -0.29 0.14 7 AV6 +0.24 0.12 6 AV7 +0.23 49 10 0.28 11 AV7 +0.16 0.22 10 AV2 -0.17 0.14 7 AV3 -0.21 0.15 7 AV6 +0.25 49 12 0.12 6 AV2 -0.17 0.14 7 AV3 -0.25 0.26 11 AV8 +0.02 49 16 0.15 7 AV3 +0.33 0.60 19 AV6 -0.03 0.15 8 AV7 +0.02 49 22 0.08 5 AV2 +0.21 49 26 0.10 6 AV3 -0.16 49 34 0.15 7 AV3 -0.16 49 128 0.10 5 AV3 -0.14 49 142 0.14 7 AV6 +0.20 49 144 0.17 8 AV3 +0.29 49 154 0.19 9 AV6 +0.18 0.30 12 AV3 -0.23 49 156 0.14 7 AV7 +0.25 49 158 0.18 9 AV7 -0.23 0.20 9 AV6 -0.31 0.21 9 AV3 +0.31 49 160 0.13 7 AV8 -0.18 0.23 10 AV7 +0.16 0.24 10 AV2 -0.21 49 162 0.19 9 AV7 +0.21 0.34 13 AV6 +0.18 0.12 6 AV3 -0.25 0.34 13 AV2 -0.20 50 7 0.14 7 AV2 +0.24 0.22 10 AV3 -0.21 0.29 12 AV6 +0.22 0.20 9 AV7 +0.25 50 9 0.20 9 AV7 +0.21 0.13 7 AV8 +0.21 0.13 7 AV2 -0.23 0.26 11 AV3 -0.21 0.32 13 AV6 +0.20 50 11 0.44 16 AV2 -0.18 0.12 6 AV3 -0.25 0.16 8 AV6 +0.20 0.23 10 AV7 +0.21 50 13 0.11 6 AV2 -0.21 0.08 5 AV3 -0.18 0.09 5 AV6 +0.20 50 15 0.17 8 AV3 -0.19 0.09 5 AV6 +0.23 0.07 4 AV7 -0.27 0.12 6 AV8 -0.18 50 19 0.13 7 AV3 -0.21 50 45 0.11 6 AV3 +0.24 50 111 0.10 5 AV6 -0.25 50 125 0.11 6 AV3 +0.00 50 137 0.11 6 AV6 +0.23 50 147 0.12 6 AV6 -0.06 50 153 0.25 11 AV6 -0.34 0.39 14 AV3 +0.29 50 155 0.57 18 AV6 -0.28 50 157 0.24 10 AV7 -0.21 0.17 8 AV6 -0.06 50 159 0.18 9 AV7 +0.24 0.19 9 AV6 +0.18 0.18 8 AV3 +0.26 0.20 9 AV2 -0.16 50 161 0.25 11 AV7 +0.21 0.36 14 AV6 +0.20 0.25 11 AV6 -0.34 0.17 8 AV3 +0.31 0.16 8 AV2 -0.20 0.11 6 AV1 -0.23 50 163 0.45 16 AV7 -0.25 0.21 9 AV6 +0.21 0.07 4 AV3 +0.29 51 8 0.28 12 AV3 -0.21 0.37 14 AV6 +0.22 0.14 7 AV8 +0.23 51 10 0.18 9 AV2 -0.18 0.20 9 AV6 +0.22 0.13 7 AV7 +0.18 0.23 10 AV8 +0.20 51 12 0.15 8 AV3 +0.00 51 16 0.11 6 AV2 -0.21 0.38 14 AV6 -0.06 0.38 14 AV7 -0.05 0.23 10 AV8 +0.00 51 18 0.16 8 AV3 +0.06 51 34 0.10 5 AV3 -0.13 51 102 0.15 7 AV6 +0.23 51 108 0.12 6 AV6 +0.18 51 128 0.09 5 AV3 -0.18 51 144 0.23 10 AV3 +0.27 51 154 0.09 5 AV7 +0.19 0.24 10 AV6 +0.16 0.41 15 AV3 -0.20 51 156 0.26 11 AV7 +0.23 0.26 11 AV6 +0.18 51 158 0.21 9 AV7 +0.19 0.12 6 AV6 -0.25 0.15 8 AV3 +0.28 51 160 0.24 10 AV8 -0.24 0.28 11 AV7 +0.19 0.22 10 AV3 +0.03 0.51 17 AV2 -0.20 0.15 7 AV1 +0.18 51 162 0.32 13 AV7 -0.23 0.51 17 AV2 -0.18 0.30 12 AV1 -0.20 0.38 14 AV3 -0.27 0.29 12 AV3 +0.28 52 9 0.20 9 AV2 -0.22 0.46 16 AV3 -0.27 0.44 16 AV6 +0.24 0.35 14 AV7 +0.00 52 11 0.21 9 AV2 -0.18 0.36 14 AV6 +0.22 0.52 17 AV7 +0.18 0.13 7 AV8 -0.16 52 13 0.23 10 AV2 -0.13 0.28 12 AV6 -0.03 0.45 16 AV7 +0.00 0.33 13 AV8 -0.02 52 15 0.26 11 AV7 +0.00 0.11 6 AV8 +0.00 52 17 0.14 7 AV2 -0.16 0.15 7 AV3 -0.14 0.22 10 AV6 +0.04 0.14 7 AV8 +0.07 52 35 0.23 10 AV3 +0.27 0.10 5 AV6 -0.29 52 111 0.11 6 AV3 -0.12 52 121 0.12 6 AV3 +0.22 52 141 0.28 12 AV6 -0.25 52 145 0.08 5 AV2 +0.13 0.14 7 AV1 +0.05 52 147 0.15 7 AV6 -0.05 52 149 0.14 7 AV6 +0.16 52 151 0.18 9 AV7 -0.15 52 153 0.49 17 AV3 +0.25 52 155 0.13 7 AV6 +0.18 52 157 0.11 6 AV6 +0.18 52 159 0.16 8 AV7 +0.21 0.34 13 AV6 -0.36 0.23 10 AV3 +0.25 0.24 10 AV2 -0.19 0.19 9 AV1 -0.23 52 161 0.42 15 AV6 +0.25 0.19 9 AV3 +0.30 0.26 11 AV2 -0.21 0.21 9 AV1 -0.18 0.38 14 AV7 -0.21 53 8 0.46 16 AV2 +0.23 0.37 14 AV3 -0.23 0.23 10 AV6 +0.22 0.17 8 AV8 +0.23 53 10 0.12 6 AV1 +0.25 0.24 10 AV2 -0.19 0.17 8 AV3 -0.21 0.36 14 AV6 +0.18 0.33 13 AV7 -0.02 0.23 10 AV8 -0.18 53 12 0.19 9 AV3 +0.05 0.11 6 AV2 -0.51 0.20 9 AV8 -0.14 53 16 0.19 9 AV6 -0.03 53 20 0.16 8 AV3 -0.21 53 34 0.19 9 AV3 -0.16 0.20 9 AV6 +0.18 53 44 0.07 5 AV3 -0.21 53 54 0.09 5 AV3 -0.02 53 102 0.13 7 AV6 +0.18 53 110 0.13 7 AV3 +0.06 53 124 0.14 7 AV3 +0.06 0.16 8 AV7 +0.02 53 128 0.18 9 AV3 -0.12 53 130 0.15 8 AV6 +0.20 53 136 0.12 6 AV6 +0.00 53 142 0.35 13 AV6 +0.17 53 144 0.17 8 AV7 +0.15 0.19 9 AV3 +0.22 0.10 5 AV8 +0.42 53 148 0.11 6 AV7 -0.04 0.15 7 AV6 -0.06 53 154 0.26 11 AV6 +0.16 0.33 13 AV3 -0.23 53 156 0.19 9 AV8 -0.11 0.46 16 AV7 +0.00 0.30 12 AV6 +0.17 53 158 0.19 9 AV8 -0.02 0.39 15 AV7 +0.19 0.19 9 AV6 -0.33 0.15 7 AV3 +0.30 53 160 0.11 6 AV8 -0.18 0.30 12 AV7 +0.16 0.14 7 AV3 +0.00 0.24 11 AV2 -0.21 53 162 0.39 15 AV7 -0.25 0.22 10 AV3 -0.20 54 9 0.12 6 AV2 -0.21 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 18 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 3 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.54 18 AV6 +0.20 0.29 12 AV8 +0.23 54 11 0.16 8 AV3 +0.30 0.22 10 AV6 +0.18 0.27 11 AV7 +0.18 54 13 0.53 18 AV6 -0.11 0.42 15 AV7 -0.05 0.24 10 AV8 +0.02 54 15 0.10 6 AV2 -0.17 0.26 11 AV3 -0.21 54 17 0.17 8 AV6 -0.29 54 19 0.16 8 AV3 -0.15 54 39 0.12 6 AV3 +0.29 54 101 0.14 7 AV6 -0.20 54 105 0.11 6 AV3 +0.03 54 109 0.21 9 AV3 +0.03 54 111 0.10 6 AV6 +0.00 54 119 0.09 5 AV6 +0.11 54 121 0.12 6 AV3 +0.16 0.13 7 AV6 -0.27 54 125 0.11 6 AV2 -0.02 54 135 0.23 10 AV6 -0.03 0.34 13 AV7 +0.02 54 137 0.15 7 AV2 -0.17 54 139 0.16 8 AV6 +0.00 54 141 0.21 9 AV6 -0.27 54 143 0.08 5 AV6 +0.16 54 145 0.11 6 AV7 +0.25 54 147 0.21 9 AV6 +0.18 54 151 0.19 9 AV7 -0.04 54 153 0.10 5 AV6 +0.23 0.21 9 AV3 +0.25 54 155 0.12 6 AV6 +0.14 0.11 6 AV1 +0.18 54 157 0.30 12 AV6 +0.16 0.43 15 AV3 -0.18 0.12 6 AV2 -0.18 0.11 6 AV1 +0.21 54 159 0.20 9 AV8 -0.24 0.39 15 AV7 +0.12 0.42 15 AV6 -0.30 0.15 8 AV3 -0.26 0.23 10 AV2 -0.14 0.17 8 AV6 +0.18 55 10 0.30 12 AV2 -0.18 0.45 16 AV3 +0.27 0.17 8 AV6 +0.20 0.12 6 AV7 +0.23 0.17 8 AV8 -0.18 0.17 8 AV3 -0.18 55 12 0.10 5 AV7 +0.19 0.24 10 AV8 -0.14 0.12 6 AV1 -0.16 0.14 7 AV2 -0.18 0.23 10 AV3 +0.27 0.14 7 AV6 +0.18 55 14 0.17 8 AV3 +0.03 0.33 13 AV6 -0.05 0.46 16 AV7 -0.02 0.22 10 AV8 +0.02 55 16 0.17 8 AV2 -0.19 0.11 6 AV3 -0.13 0.38 14 AV7 -0.02 0.23 10 AV8 +0.02 55 20 0.18 9 AV3 -0.15 55 26 0.11 6 AV3 -0.19 55 34 0.14 7 AV3 -0.17 0.13 7 AV6 +0.20 55 38 0.11 6 AV3 -0.17 55 108 0.16 8 AV6 +0.18 55 112 0.14 7 AV6 +0.18 55 116 0.16 8 AV6 +0.00 55 118 0.14 7 AV3 +0.05 55 120 0.18 8 AV3 -0.21 55 122 0.11 6 AV6 -0.24 0.15 7 AV7 +0.00 55 128 0.13 7 AV3 -0.16 55 130 0.12 6 AV6 +0.18 55 134 0.13 7 AV6 +0.16 55 142 0.24 10 AV6 +0.16 55 144 0.15 7 AV3 +0.20 55 148 0.12 6 AV6 +0.16 55 154 0.16 8 AV6 +0.19 0.29 12 AV3 -0.22 0.13 7 AV1 +0.21 55 156 0.24 10 AV7 +0.25 0.17 8 AV6 -0.03 0.20 9 AV1 +0.23 55 158 0.39 14 AV7 +0.20 0.26 11 AV6 -0.33 0.14 7 AV3 +0.30 55 160 0.45 16 AV7 -0.26 0.59 19 AV6 -0.27 0.13 7 AV3 -0.39 0.35 13 AV2 -0.18 0.29 12 AV1 +0.21 56 9 0.25 11 AV3 -0.21 0.22 10 AV7 +0.23 0.16 8 AV8 +0.21 56 11 0.14 7 AV1 -0.19 0.26 11 AV2 -0.21 0.29 12 AV3 +0.21 0.19 9 AV6 +0.31 0.38 14 AV7 +0.00 0.20 9 AV8 +0.18 56 13 0.13 7 AV3 -0.16 0.14 7 AV6 +0.22 0.19 9 AV8 +0.00 56 15 0.10 5 AV3 -0.18 0.11 6 AV6 +0.20 0.11 6 AV7 +0.14 0.10 6 AV8 -0.16 56 17 0.15 8 AV2 +0.00 0.12 6 AV3 +0.05 0.46 16 AV6 -0.03 0.14 7 AV7 +0.02 0.19 9 AV8 +0.02 56 19 0.11 6 AV3 -0.19 56 25 0.11 6 AV3 +0.24 56 33 0.13 7 AV6 +0.16 56 35 0.18 8 AV3 +0.26 56 43 0.14 7 AV3 -0.18 0.17 8 AV6 -0.13 56 107 0.13 7 AV3 +0.03 56 111 0.17 8 AV6 +0.02 56 113 0.14 7 AV2 +0.03 56 121 0.11 6 AV3 +0.21 0.17 8 AV6 +0.00 0.10 5 AV7 +0.00 56 123 0.09 5 AV3 +0.03 0.13 7 AV6 -0.03 56 125 0.08 5 AV2 -0.16 56 127 0.12 6 AV6 +0.16 56 137 0.15 8 AV6 +0.00 0.30 12 AV7 +0.05 56 139 0.12 6 AV7 +0.02 56 143 0.12 6 AV6 +0.18 0.37 14 AV3 -0.02 56 147 0.27 11 AV7 -0.21 0.42 15 AV6 -0.26 56 149 0.38 14 AV6 -0.08 0.17 8 AV3 +0.05 56 153 0.17 8 AV6 -0.03 0.28 12 AV3 +0.24 56 155 0.14 7 AV8 -0.16 56 157 0.16 8 AV6 +0.19 0.12 6 AV1 +0.18 56 159 0.10 5 AV8 +0.16 0.30 12 AV7 +0.18 0.37 14 AV2 -0.14 0.24 10 AV1 -0.20 56 161 0.29 12 AV7 -0.21 0.58 18 AV6 +0.23 0.20 9 AV2 +0.18 57 10 0.11 6 AV1 -0.26 0.23 10 AV2 -0.21 0.15 7 AV3 -0.16 0.21 9 AV6 +0.23 0.17 8 AV7 +0.16 57 12 0.19 9 AV3 +0.24 0.12 6 AV6 +0.00 0.15 7 AV8 -0.16 57 14 0.13 7 AV2 +0.05 0.18 8 AV3 +0.03 0.18 8 AV6 +0.05 57 18 0.13 7 AV2 -0.19 0.16 8 AV3 -0.10 0.07 4 AV8 -0.14 57 20 0.20 9 AV3 -0.21 57 22 0.18 8 AV3 -0.12 57 28 0.13 7 AV3 -0.16 57 100 0.13 7 AV3 +0.03 0.17 8 AV6 +0.14 57 102 0.19 9 AV6 +0.18 57 104 0.12 6 AV6 +0.00 57 108 0.15 7 AV6 +0.15 57 110 0.11 6 AV7 +0.02 57 112 0.12 6 AV6 +0.02 57 116 0.29 12 AV3 +0.03 57 120 0.17 8 AV3 -0.16 0.13 7 AV6 +0.00 57 124 0.09 5 AV6 +0.20 57 126 0.18 8 AV6 +0.02 0.18 9 AV7 +0.02 57 128 0.12 6 AV3 -0.16 0.09 5 AV6 +0.25 57 136 0.24 10 AV6 +0.00 0.15 7 AV7 +0.02 57 138 0.14 7 AV3 +0.00 0.26 11 AV6 -0.03 57 142 0.14 7 AV7 -0.02 0.26 11 AV6 +0.20 57 144 0.10 6 AV3 +0.19 57 148 0.21 9 AV6 +0.14 57 154 0.19 9 AV6 +0.14 0.37 14 AV3 -0.23 0.22 10 AV2 +0.00 0.16 8 AV1 -0.21 57 156 0.10 5 AV8 -0.19 0.28 12 AV7 +0.23 0.15 8 AV6 +0.19 0.20 9 AV1 +0.21 57 158 0.21 10 AV8 -0.16 0.23 10 AV7 +0.16 0.37 14 AV3 +0.03 0.35 13 AV2 -0.02 57 160 0.41 15 AV7 -0.02 0.47 16 AV6 -0.29 0.17 8 AV6 +0.21 0.47 16 AV3 +0.29 0.19 9 AV2 -0.23 0.17 8 AV1 -0.20 58 9 0.34 13 AV3 -0.18 0.42 15 AV6 +0.20 0.51 17 AV7 -0.20 0.23 10 AV8 +0.20 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 19 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 4 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 58 11 0.21 10 AV1 -0.14 0.36 14 AV2 -0.23 0.23 10 AV3 +0.29 0.50 17 AV8 -0.14 58 13 0.11 6 AV1 +0.03 0.14 7 AV3 -0.18 0.48 16 AV6 -0.05 0.23 10 AV7 -0.02 58 15 0.12 6 AV1 +0.17 0.12 6 AV2 +0.16 0.16 8 AV6 +0.00 0.14 7 AV7 +0.02 0.09 5 AV8 -0.12 58 17 0.27 11 AV3 -0.14 0.15 8 AV6 -0.03 0.14 7 AV8 -0.14 58 19 0.19 9 AV6 +0.00 0.18 8 AV7 -0.02 0.15 7 AV8 +0.05 58 25 0.11 6 AV3 -0.16 58 35 0.16 8 AV3 +0.25 0.16 8 AV6 -0.25 58 43 0.11 6 AV6 -0.23 58 73 0.13 7 AV6 +0.00 58 75 0.17 8 AV6 +0.00 0.19 9 AV7 +0.00 58 101 0.09 5 AV6 -0.16 58 109 0.10 6 AV6 +0.02 58 113 0.13 7 AV2 +0.02 0.20 9 AV7 -0.02 58 115 0.14 7 AV3 +0.00 58 117 0.14 7 AV2 -0.02 58 119 0.14 7 AV3 -0.19 58 121 0.13 7 AV6 -0.03 58 125 0.11 6 AV6 -0.03 0.10 6 AV2 +0.00 0.12 6 AV3 +0.05 58 127 0.12 6 AV6 +0.16 58 129 0.18 8 AV2 +0.02 0.16 8 AV3 +0.03 58 131 0.29 12 AV6 +0.00 58 133 0.35 14 AV6 -0.05 58 137 0.18 8 AV3 +0.03 58 141 0.18 9 AV7 +0.14 58 145 0.22 10 AV6 -0.03 0.16 8 AV3 -0.02 0.16 8 AV1 +0.47 58 147 0.16 8 AV7 -0.20 0.14 7 AV6 +0.00 0.21 10 AV3 +0.03 58 151 0.25 11 AV7 -0.05 0.17 8 AV1 -0.21 58 153 0.17 8 AV6 +0.19 0.15 8 AV3 -0.18 0.13 7 AV1 -0.23 58 155 0.18 9 AV8 -0.19 0.34 13 AV6 -0.05 0.08 5 AV2 -0.19 0.11 6 AV1 -0.13 58 157 0.11 6 AV6 +0.19 0.15 7 AV3 -0.18 0.16 8 AV2 -0.16 0.19 9 AV1 -0.20 58 159 0.14 7 AV7 +0.21 0.19 9 AV6 +0.19 0.42 15 AV3 +0.21 0.20 9 AV1 -0.18 58 161 0.35 14 AV7 -0.21 0.56 18 AV6 +0.19 0.27 11 AV6 -0.31 0.22 10 AV3 -0.20 59 10 0.12 6 AV1 -0.19 0.25 11 AV2 -0.19 0.35 13 AV3 -0.16 0.22 10 AV6 +0.18 0.14 7 AV7 +0.23 0.39 14 AV8 +0.21 59 12 0.17 8 AV1 +0.21 0.13 7 AV2 -0.14 0.33 13 AV3 +0.26 0.50 17 AV7 -0.18 0.30 12 AV8 -0.18 59 14 0.13 7 AV2 +0.21 0.23 10 AV3 +0.03 0.29 12 AV6 -0.05 0.24 10 AV7 -0.05 0.16 8 AV8 -0.18 59 16 0.11 6 AV1 -0.17 59 18 0.19 9 AV3 -0.16 0.16 8 AV6 -0.23 59 20 0.22 10 AV3 -0.24 59 22 0.11 6 AV8 +0.16 59 24 0.10 6 AV2 +0.16 0.10 6 AV3 +0.23 59 26 0.09 5 AV2 -0.17 59 34 0.12 6 AV3 -0.18 0.11 6 AV6 +0.16 59 44 0.11 6 AV3 -0.18 59 58 0.08 5 AV6 -0.46 59 68 0.17 8 AV2 +0.02 0.26 11 AV3 +0.00 0.27 11 AV6 +0.00 0.24 10 AV7 +0.02 59 76 0.16 8 AV3 +0.03 0.13 7 AV6 +0.02 59 84 0.32 13 AV6 +0.02 0.46 16 AV7 +0.00 0.27 11 AV8 -0.02 59 100 0.13 7 AV6 +0.13 59 102 0.14 7 AV3 +0.00 0.21 9 AV6 +0.14 59 104 0.13 7 AV3 +0.03 0.18 9 AV6 +0.05 59 106 0.12 6 AV3 +0.00 0.21 10 AV6 +0.02 59 108 0.22 10 AV3 +0.03 0.17 8 AV6 +0.02 59 110 0.50 17 AV3 +0.03 0.24 10 AV2 -0.02 0.48 17 AV6 +0.00 59 116 0.16 8 AV6 -0.03 59 118 0.15 7 AV3 +0.03 59 120 0.18 9 AV3 -0.16 59 124 0.13 7 AV6 +0.18 59 128 0.13 7 AV6 +0.20 59 132 0.11 6 AV7 +0.18 59 140 0.20 9 AV2 +0.02 59 142 0.21 9 AV6 -0.03 0.24 10 AV2 +0.00 59 144 0.16 8 AV2 -0.02 59 148 0.23 10 AV6 -0.05 0.17 8 AV3 -0.02 0.20 9 AV2 +0.00 0.14 7 AV1 -0.02 59 150 0.37 14 AV3 +0.00 0.18 8 AV2 -0.02 59 152 0.27 11 AV6 -0.05 0.18 9 AV3 +0.03 0.18 8 AV2 +0.00 0.09 5 AV1 -0.25 59 154 0.14 7 AV6 +0.17 0.28 12 AV3 -0.20 0.13 7 AV1 -0.02 59 156 0.40 15 AV8 -0.19 0.30 12 AV7 +0.24 0.13 7 AV1 -0.02 59 160 0.15 7 AV8 +0.19 0.28 11 AV7 -0.24 0.22 10 AV3 +0.29 0.43 15 AV2 +0.18 60 11 0.13 7 AV1 -0.23 0.22 10 AV2 -0.21 0.37 14 AV3 +0.23 0.27 11 AV8 +0.20 60 13 0.17 8 AV2 -0.18 0.11 6 AV3 -0.16 0.41 15 AV6 -0.05 0.18 9 AV8 +0.05 60 15 0.09 5 AV3 +0.26 0.29 12 AV6 -0.23 60 17 0.15 8 AV2 -0.21 0.13 7 AV3 -0.16 0.16 8 AV8 +0.00 60 19 0.20 9 AV6 -0.03 60 21 0.23 10 AV6 -0.20 60 31 0.35 13 AV6 -0.03 0.14 7 AV7 +0.00 60 33 0.15 7 AV6 -0.03 60 53 0.11 6 AV6 +0.16 60 61 0.25 11 AV6 +0.05 60 67 0.21 10 AV3 +0.00 0.14 7 AV6 +0.02 0.14 7 AV7 +0.05 60 103 0.13 7 AV2 +0.00 0.16 8 AV3 +0.03 60 109 0.29 12 AV3 +0.05 0.21 9 AV6 +0.00 0.24 10 AV7 -0.02 60 111 0.16 8 AV6 +0.00 60 121 0.11 6 AV3 +0.11 0.30 12 AV6 -0.03 60 123 0.17 8 AV6 -0.03 60 127 0.21 9 AV6 +0.00 60 129 0.21 9 AV6 -0.20 0.13 7 AV7 +0.02 60 135 0.19 9 AV3 +0.05 0.52 17 AV6 -0.03 0.35 13 AV7 +0.00 60 137 0.33 13 AV6 -0.03 0.41 15 AV7 +0.02 60 141 0.19 9 AV8 -0.02 0.30 12 AV7 +0.00 60 145 0.15 7 AV8 -0.22 0.12 6 AV7 +0.00 60 147 0.15 7 AV6 +0.19 60 149 0.24 10 AV6 -0.23 60 151 0.18 8 AV3 +0.00 60 153 0.35 13 AV8 +0.00 0.36 14 AV7 -0.02 0.32 13 AV3 +0.03 60 155 0.22 10 AV6 -0.28 0.13 7 AV1 -0.20 0.11 6 AV7 +0.16 60 157 0.21 10 AV8 +0.16 0.37 14 AV3 -0.02 0.12 6 AV1 -0.20 60 159 0.17 8 AV8 +0.16 0.26 11 AV7 +0.16 0.34 13 AV6 -0.05 0.41 15 AV3 +0.23 0.17 8 AV2 -0.21 0.39 14 AV1 -0.18 61 10 0.12 7 AV7 +0.21 0.25 11 AV8 +0.20 0.08 5 AV2 -0.21 0.29 12 AV3 -0.14 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 20 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 5 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.52 17 AV6 +0.21 61 12 0.22 10 AV3 +0.23 0.22 10 AV6 -0.18 61 14 0.16 8 AV2 -0.19 0.16 8 AV3 -0.21 0.16 8 AV6 +0.00 0.26 11 AV7 -0.02 0.26 11 AV8 +0.00 61 16 0.19 9 AV3 -0.22 61 18 0.11 6 AV3 +0.25 0.55 18 AV6 -0.08 0.31 12 AV7 +0.00 61 20 0.13 7 AV3 -0.18 0.40 15 AV6 -0.05 0.15 7 AV7 +0.00 61 22 0.32 13 AV3 -0.21 0.16 8 AV6 +0.00 61 28 0.09 5 AV2 +0.02 61 30 0.13 7 AV3 +0.00 0.13 7 AV6 -0.03 61 32 0.11 6 AV3 +0.21 0.18 8 AV6 -0.03 61 34 0.19 9 AV3 -0.17 0.13 7 AV6 +0.21 61 38 0.26 11 AV6 +0.00 0.19 9 AV7 -0.02 61 44 0.14 7 AV3 -0.23 61 48 0.08 5 AV3 -0.18 61 50 0.15 8 AV3 +0.03 61 60 0.16 8 AV3 +0.00 0.20 9 AV6 +0.02 61 102 0.25 11 AV3 +0.00 0.51 17 AV6 +0.02 61 104 0.14 7 AV2 +0.00 0.17 8 AV3 +0.16 0.21 10 AV6 +0.00 61 106 0.23 10 AV6 +0.02 61 108 0.16 8 AV2 +0.02 0.24 10 AV3 +0.03 0.23 10 AV6 -0.05 61 110 0.18 9 AV3 +0.00 0.13 7 AV6 +0.05 61 112 0.32 13 AV3 +0.00 0.13 7 AV6 +0.23 61 114 0.18 9 AV2 +0.00 0.27 11 AV3 +0.00 0.25 11 AV6 +0.00 61 116 0.17 8 AV2 -0.02 0.47 16 AV3 +0.00 0.26 11 AV7 +0.00 61 118 0.18 8 AV6 -0.05 61 126 0.12 6 AV3 +0.03 0.10 5 AV6 +0.21 61 130 0.17 8 AV7 +0.00 0.11 6 AV3 +0.00 0.49 17 AV6 +0.00 61 134 0.17 8 AV6 +0.16 0.12 6 AV7 +0.09 61 140 0.16 8 AV6 +0.14 61 142 0.56 18 AV6 -0.05 0.09 5 AV2 +0.18 61 144 0.17 8 AV6 -0.08 61 146 0.34 13 AV6 -0.21 0.14 7 AV3 +0.00 61 152 0.14 7 AV8 -0.22 0.40 15 AV6 -0.20 0.19 9 AV3 -0.02 61 154 0.13 7 AV8 +0.00 0.17 8 AV7 -0.19 0.34 13 AV6 -0.05 0.11 6 AV3 -0.05 61 156 0.34 13 AV7 +0.21 0.32 13 AV3 +0.26 0.31 12 AV1 +0.00 0.31 12 AV2 +0.00 61 158 0.38 14 AV7 +0.19 0.20 9 AV6 -0.03 0.45 16 AV3 +0.23 0.37 14 AV2 -0.16 61 160 0.36 14 AV7 -0.24 0.22 10 AV6 -0.31 0.36 14 AV3 -0.21 62 11 0.21 9 AV1 -0.17 0.27 11 AV2 +0.21 0.36 14 AV3 +0.31 0.32 13 AV6 +0.43 0.22 10 AV8 +0.21 0.49 17 AV7 -0.23 62 13 0.10 5 AV1 -0.19 0.10 6 AV2 -0.19 0.29 12 AV3 -0.09 0.20 9 AV7 +0.21 0.17 8 AV8 +0.23 62 15 0.45 16 AV7 -0.02 0.13 7 AV8 +0.02 62 17 0.09 5 AV2 +0.20 0.13 7 AV3 -0.15 62 19 0.08 5 AV1 -0.29 0.07 4 AV3 +0.05 62 23 0.14 7 AV1 +0.05 0.15 8 AV2 +0.05 62 25 0.08 5 AV3 -0.14 62 31 0.09 5 AV3 -0.35 62 35 0.13 7 AV3 +0.23 0.21 9 AV6 -0.23 62 45 0.26 11 AV6 +0.00 62 59 0.27 11 AV3 +0.05 0.51 17 AV6 +0.02 0.45 16 AV7 +0.00 62 61 0.17 8 AV6 +0.02 0.13 7 AV7 +0.02 62 65 0.24 11 AV6 +0.05 62 73 0.24 11 AV3 +0.03 0.33 13 AV6 +0.00 0.17 8 AV7 +0.05 62 95 0.16 8 AV3 -0.14 62 97 0.09 5 AV6 +0.00 62 99 0.09 5 AV6 +0.19 62 103 0.16 8 AV3 -0.02 0.17 8 AV6 +0.05 62 105 0.16 8 AV3 +0.03 0.21 9 AV7 +0.02 62 107 0.28 12 AV3 +0.03 62 109 0.26 11 AV2 -0.02 0.34 13 AV3 +0.03 0.20 9 AV6 +0.07 62 111 0.22 10 AV6 +0.00 62 113 0.11 6 AV2 +0.02 0.14 7 AV3 +0.00 0.15 7 AV6 -0.03 0.28 12 AV7 -0.05 62 115 0.23 10 AV3 +0.00 0.26 11 AV6 +0.00 0.23 10 AV7 -0.05 62 117 0.20 9 AV3 +0.00 62 119 0.14 7 AV3 -0.19 62 121 0.32 13 AV6 -0.05 62 129 0.16 8 AV6 -0.20 62 131 0.59 19 AV6 -0.03 62 139 0.15 7 AV2 -0.16 62 143 0.24 10 AV7 -0.02 0.18 8 AV6 +0.00 62 151 0.25 11 AV3 +0.03 0.19 9 AV1 +0.00 62 153 0.52 17 AV3 +0.05 62 155 0.10 6 AV7 +0.16 62 157 0.38 14 AV8 +0.16 0.28 11 AV7 +0.19 0.22 10 AV3 +0.03 0.12 6 AV2 -0.21 0.17 8 AV1 -0.20 62 159 0.22 10 AV8 +0.20 0.21 9 AV3 +0.21 0.28 12 AV2 +0.16 0.25 11 AV1 -0.21 63 12 0.18 8 AV1 +0.18 0.26 11 AV2 +0.05 0.12 6 AV7 +0.21 63 14 0.14 7 AV1 +0.00 0.12 6 AV2 +0.02 0.19 9 AV3 -0.18 0.18 8 AV6 -0.23 0.16 8 AV7 +0.18 0.10 6 AV8 +0.20 63 16 0.16 8 AV2 -0.12 0.40 15 AV3 +0.03 0.18 8 AV6 +0.00 0.13 7 AV7 +0.18 0.24 10 AV8 +0.14 63 18 0.16 8 AV3 +0.26 0.12 6 AV7 +0.00 0.24 11 AV8 +0.00 63 34 0.17 8 AV3 +0.03 0.44 16 AV6 +0.16 63 38 0.20 9 AV7 -0.18 0.14 7 AV8 +0.02 63 44 0.16 8 AV2 -0.02 0.14 7 AV3 -0.02 63 46 0.10 6 AV6 +0.00 63 58 0.15 7 AV3 +0.00 0.25 11 AV6 +0.05 63 60 0.10 6 AV3 -0.14 0.16 8 AV6 +0.02 63 64 0.21 9 AV3 +0.03 0.39 14 AV6 +0.02 63 74 0.32 13 AV6 +0.05 63 76 0.21 9 AV3 +0.00 0.26 11 AV6 +0.05 63 78 0.49 17 AV3 +0.03 0.23 10 AV6 +0.05 63 90 0.10 6 AV2 +0.07 63 98 0.22 10 AV3 +0.00 0.14 7 AV6 +0.00 63 100 0.44 16 AV6 +0.05 63 102 0.13 7 AV2 +0.07 0.24 10 AV6 +0.20 63 104 0.16 8 AV2 +0.00 0.14 7 AV3 +0.10 0.51 17 AV6 +0.05 0.20 9 AV7 +0.02 63 106 0.47 16 AV3 +0.03 0.29 12 AV6 +0.02 63 108 0.16 8 AV6 +0.14 63 110 0.15 7 AV3 +0.05 0.41 15 AV6 -0.03 63 112 0.14 7 AV7 +0.00 63 114 0.31 12 AV3 +0.00 0.40 15 AV7 +0.00 63 116 0.31 12 AV6 -0.03 63 118 0.16 8 AV6 -0.03 63 128 0.15 7 AV6 +0.18 63 130 0.21 9 AV6 +0.16 63 132 0.40 15 AV3 +0.08 0.48 16 AV6 +0.00 63 134 0.21 9 AV2 +0.02 0.16 8 AV3 +0.03 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 21 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 6 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 63 136 0.53 17 AV6 +0.00 0.16 8 AV7 +0.05 63 142 0.23 10 AV6 -0.05 63 144 0.22 10 AV8 -0.02 0.13 7 AV7 +0.00 0.38 14 AV3 +0.18 0.15 7 AV2 -0.02 63 146 0.35 14 AV3 +0.00 0.11 6 AV2 -0.02 0.17 8 AV7 -0.02 63 148 0.40 15 AV6 -0.20 0.21 10 AV3 +0.03 0.14 7 AV1 -0.16 63 150 0.20 9 AV7 +0.02 0.17 8 AV6 -0.05 0.51 17 AV3 +0.03 0.25 11 AV2 +0.02 0.15 7 AV1 +0.21 63 152 0.13 7 AV8 -0.16 0.11 6 AV7 +0.00 0.27 11 AV6 -0.26 0.17 8 AV1 -0.21 63 154 0.12 6 AV8 -0.18 0.33 13 AV6 -0.05 0.25 11 AV3 -0.18 0.26 11 AV2 +0.02 0.17 8 AV1 -0.21 63 156 0.30 12 AV8 -0.16 0.35 13 AV7 +0.18 0.51 17 AV6 -0.05 0.21 10 AV2 +0.16 0.53 18 AV1 -0.18 64 11 0.17 8 AV3 -0.21 0.26 11 AV6 +0.21 0.32 13 AV7 +0.00 64 13 0.46 16 AV3 +0.03 0.15 7 AV8 -0.18 0.12 6 AV1 +0.00 0.16 8 AV2 -0.12 64 15 0.13 7 AV3 +0.22 0.22 10 AV6 -0.22 64 17 0.29 12 AV3 +0.03 0.32 13 AV7 +0.00 0.44 16 AV8 +0.02 64 19 0.36 14 AV6 -0.02 64 27 0.29 12 AV6 -0.02 64 29 0.28 11 AV7 +0.02 64 33 0.15 7 AV3 -0.18 0.53 17 AV6 +0.02 64 39 0.15 7 AV6 +0.00 64 45 0.12 6 AV6 +0.02 64 55 0.16 8 AV3 -0.02 0.16 8 AV6 +0.00 64 61 0.13 7 AV6 +0.02 64 63 0.17 8 AV2 +0.00 0.23 10 AV3 +0.02 0.45 16 AV6 +0.02 64 75 0.13 7 AV2 +0.00 0.31 12 AV3 +0.02 0.18 9 AV7 +0.02 64 87 0.16 8 AV2 -0.16 64 91 0.13 7 AV2 -0.07 64 93 0.15 8 AV6 +0.07 64 97 0.24 10 AV6 +0.02 64 99 0.26 11 AV3 +0.03 0.18 8 AV6 +0.02 64 101 0.29 12 AV3 +0.03 0.62 19 AV6 +0.05 0.38 14 AV7 +0.00 64 103 0.13 7 AV6 -0.05 0.11 6 AV7 +0.05 0.17 8 AV3 -0.02 64 105 0.17 8 AV3 -0.02 0.61 19 AV6 +0.05 0.15 8 AV7 +0.02 64 109 0.15 8 AV6 +0.00 64 111 0.24 10 AV3 -0.02 0.37 14 AV6 -0.02 64 113 0.12 6 AV2 -0.02 0.21 9 AV3 +0.00 0.09 5 AV6 +0.00 0.19 9 AV7 +0.00 64 115 0.45 16 AV3 +0.05 0.50 17 AV6 -0.02 64 117 0.19 9 AV3 +0.03 64 119 0.09 5 AV2 -0.02 0.24 10 AV3 +0.03 0.18 8 AV6 +0.02 64 121 0.15 7 AV6 -0.03 64 123 0.13 7 AV6 +0.00 64 125 0.10 6 AV2 +0.00 64 131 0.27 11 AV6 -0.05 64 133 0.26 11 AV6 +0.00 64 135 0.46 16 AV6 -0.03 64 137 0.26 11 AV7 +0.02 0.21 10 AV3 +0.00 0.36 14 AV6 -0.03 64 143 0.15 7 AV3 -0.07 64 145 0.10 6 AV7 -0.13 0.14 7 AV3 -0.02 0.22 10 AV1 +0.00 64 147 0.12 6 AV1 -0.02 64 149 0.28 12 AV2 -0.02 64 153 0.18 8 AV8 -0.14 0.25 11 AV6 -0.03 0.41 15 AV3 +0.00 64 155 0.19 9 AV8 -0.16 0.24 10 AV7 +0.16 0.24 10 AV6 -0.03 0.12 6 AV2 +0.16 0.48 17 AV1 -0.20 64 157 0.18 8 AV8 +0.16 0.24 10 AV7 +0.21 0.27 11 AV6 -0.18 0.22 10 AV1 +0.21 64 159 0.21 9 AV7 -0.16 0.11 6 AV6 +0.21 65 12 0.14 7 AV1 -0.17 0.39 14 AV2 +0.21 0.31 12 AV3 +0.22 0.14 7 AV8 +0.21 65 14 0.14 7 AV1 +0.21 0.30 12 AV2 +0.00 0.57 18 AV3 +0.05 0.37 14 AV6 +0.00 0.19 9 AV7 +0.00 65 16 0.14 7 AV2 -0.19 0.20 9 AV3 +0.02 0.36 14 AV7 +0.00 0.42 15 AV8 +0.02 65 18 0.59 19 AV6 -0.02 0.28 12 AV7 +0.02 65 20 0.13 7 AV2 +0.00 0.18 8 AV6 +0.00 65 22 0.17 8 AV6 -0.02 0.22 10 AV7 +0.00 65 34 0.11 6 AV6 +0.20 65 42 0.47 16 AV6 -0.02 65 44 0.13 7 AV3 -0.02 0.17 8 AV7 -0.02 0.09 5 AV8 +0.05 65 48 0.29 12 AV6 +0.02 65 50 0.22 10 AV6 +0.00 0.16 8 AV7 +0.00 65 56 0.10 6 AV6 +0.16 65 58 0.25 11 AV6 +0.00 65 62 0.13 7 AV3 +0.00 0.09 5 AV6 +0.02 65 66 0.14 7 AV6 +0.02 65 68 0.11 6 AV3 +0.18 65 70 0.08 5 AV2 +0.00 0.28 12 AV3 +0.05 0.31 12 AV6 +0.00 0.32 13 AV7 +0.00 65 74 0.31 12 AV6 +0.02 0.19 9 AV7 +0.00 65 78 0.10 5 AV3 +0.08 65 84 0.16 8 AV2 +0.00 0.24 10 AV3 +0.00 0.22 10 AV6 +0.02 65 86 0.15 8 AV7 +0.05 65 90 0.18 8 AV2 +0.02 65 94 0.32 13 AV6 +0.00 65 96 0.27 11 AV3 +0.03 65 98 0.28 12 AV3 +0.03 0.36 14 AV6 +0.05 65 100 0.15 7 AV6 +0.16 65 102 0.12 6 AV3 +0.03 0.52 17 AV6 +0.02 0.26 11 AV7 +0.02 65 104 0.12 6 AV7 -0.02 0.20 9 AV3 +0.03 0.11 6 AV6 +0.05 65 106 0.25 11 AV3 +0.00 0.27 11 AV6 +0.02 0.23 10 AV7 +0.02 65 108 0.28 12 AV3 +0.00 0.26 11 AV7 +0.02 65 110 0.17 8 AV3 +0.07 0.49 17 AV7 +0.00 65 112 0.13 7 AV2 +0.02 0.08 5 AV3 +0.02 0.32 13 AV6 +0.16 0.26 11 AV7 +0.02 65 114 0.14 7 AV2 +0.00 0.53 17 AV3 +0.03 0.33 13 AV6 -0.05 65 116 0.59 19 AV3 +0.02 0.51 17 AV6 -0.05 0.25 11 AV7 +0.02 65 118 0.11 6 AV2 +0.02 0.11 6 AV3 -0.18 0.24 11 AV6 -0.02 0.21 9 AV7 +0.05 65 120 0.22 10 AV3 +0.03 0.56 18 AV6 -0.03 0.23 10 AV7 +0.02 65 126 0.11 6 AV6 +0.14 65 128 0.38 14 AV6 +0.00 65 130 0.19 9 AV2 +0.00 0.20 9 AV3 -0.02 0.13 7 AV6 +0.21 65 134 0.13 7 AV2 +0.02 0.39 14 AV7 +0.07 65 136 0.33 13 AV6 -0.02 65 138 0.23 10 AV3 +0.03 0.16 8 AV6 +0.02 65 144 0.21 10 AV8 -0.02 65 152 0.48 17 AV8 -0.14 65 154 0.61 19 AV7 -0.02 0.20 9 AV1 +0.16 0.27 11 AV8 +0.00 65 156 0.49 17 AV8 -0.16 0.12 6 AV7 +0.20 0.15 7 AV6 -0.30 0.13 7 AV3 +0.23 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 22 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 7 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.17 8 AV2 +0.16 0.22 10 AV1 -0.20 65 158 0.21 9 AV7 -0.02 0.23 10 AV3 +0.28 0.17 8 AV8 +0.14 66 13 0.29 12 AV7 -0.02 0.17 8 AV1 +0.21 0.14 7 AV3 +0.02 66 15 0.21 9 AV1 +0.05 0.45 16 AV2 +0.02 0.43 15 AV7 -0.02 0.41 15 AV8 +0.02 66 17 0.15 7 AV2 +0.16 66 19 0.14 7 AV3 +0.03 0.37 14 AV6 +0.02 66 21 0.13 7 AV6 -0.22 0.14 7 AV3 +0.00 66 23 0.51 17 AV6 +0.00 66 27 0.23 10 AV2 +0.07 66 29 0.28 12 AV6 -0.03 66 31 0.13 7 AV3 +0.07 0.56 18 AV6 -0.02 0.60 19 AV7 +0.00 0.37 14 AV8 +0.02 66 33 0.11 6 AV2 +0.00 0.11 6 AV3 +0.00 0.26 11 AV6 +0.02 66 41 0.16 8 AV6 -0.02 66 43 0.32 13 AV6 -0.12 0.12 6 AV7 -0.02 66 45 0.12 6 AV3 +0.02 66 51 0.14 7 AV3 +0.02 0.39 14 AV6 +0.02 66 53 0.14 7 AV3 +0.02 0.12 6 AV6 +0.02 66 55 0.19 9 AV3 +0.02 0.17 8 AV6 -0.02 66 59 0.17 8 AV3 +0.02 0.42 15 AV6 +0.00 0.30 12 AV7 +0.05 66 61 0.33 13 AV3 +0.00 0.19 9 AV7 +0.00 66 65 0.17 8 AV6 +0.02 66 75 0.40 15 AV6 +0.02 0.20 9 AV7 +0.02 66 77 0.13 7 AV2 +0.02 0.15 7 AV3 +0.00 0.13 7 AV6 +0.00 66 79 0.14 7 AV3 +0.02 66 83 0.15 7 AV2 -0.12 66 87 0.17 8 AV2 -0.14 66 93 0.22 10 AV6 +0.05 66 95 0.15 7 AV2 +0.02 0.24 10 AV3 +0.00 0.19 9 AV6 +0.02 0.28 11 AV7 -0.02 66 97 0.40 15 AV3 +0.00 0.22 10 AV6 +0.00 66 99 0.18 9 AV2 +0.02 0.45 16 AV3 +0.05 0.38 14 AV7 +0.02 66 101 0.14 7 AV2 +0.02 0.19 9 AV3 +0.03 66 103 0.57 18 AV3 -0.05 0.31 12 AV8 +0.02 66 105 0.23 10 AV2 +0.07 0.23 10 AV7 +0.02 66 107 0.29 12 AV3 +0.00 0.32 13 AV6 -0.03 66 109 0.18 9 AV2 +0.02 0.40 15 AV6 +0.02 0.23 10 AV7 +0.05 0.16 8 AV8 +0.05 66 111 0.27 11 AV2 +0.00 0.43 15 AV3 +0.02 0.19 9 AV6 +0.05 66 115 0.19 9 AV2 +0.05 0.33 13 AV3 +0.00 66 117 0.13 7 AV1 +0.00 0.11 6 AV3 +0.05 0.31 12 AV6 -0.02 66 119 0.15 7 AV3 +0.03 66 121 0.27 11 AV7 +0.02 66 123 0.11 6 AV3 +0.03 66 127 0.18 9 AV6 +0.11 66 129 0.31 12 AV6 +0.00 66 131 0.16 8 AV3 +0.05 0.27 11 AV6 +0.00 66 135 0.48 16 AV6 -0.02 66 137 0.31 13 AV6 +0.00 0.27 11 AV7 +0.04 0.25 11 AV8 +0.02 66 141 0.22 10 AV6 -0.23 0.13 7 AV3 +0.05 66 143 0.16 8 AV3 -0.02 66 145 0.62 19 AV8 -0.02 0.59 19 AV6 -0.05 0.16 8 AV3 +0.00 0.16 8 AV1 +0.00 66 147 0.44 16 AV6 -0.03 0.21 9 AV3 +0.00 66 149 0.19 9 AV6 +0.12 0.18 9 AV3 +0.03 0.25 11 AV2 -0.02 0.12 6 AV1 -0.02 66 151 0.15 8 AV8 -0.16 66 153 0.18 8 AV1 -0.02 66 155 0.16 8 AV8 -0.16 0.14 7 AV7 +0.16 0.20 9 AV3 -0.02 0.23 10 AV1 +0.21 0.15 7 AV6 +0.00 66 157 0.32 13 AV8 +0.19 0.30 12 AV7 -0.02 0.31 12 AV6 -0.25 0.36 14 AV3 +0.05 0.28 12 AV1 -0.20 67 12 0.24 11 AV6 +0.20 0.23 10 AV8 +0.16 67 14 0.15 7 AV2 +0.00 0.16 8 AV3 +0.02 0.20 9 AV6 -0.25 67 16 0.12 6 AV1 +0.19 0.20 9 AV2 +0.03 0.31 12 AV6 +0.00 0.45 16 AV7 +0.00 67 18 0.11 6 AV1 +0.21 0.10 6 AV3 -0.08 67 20 0.29 12 AV3 +0.05 0.24 10 AV7 +0.02 67 34 0.19 9 AV3 +0.02 0.21 9 AV6 +0.02 67 38 0.18 8 AV2 +0.03 0.52 17 AV3 +0.02 0.47 16 AV6 +0.00 0.22 10 AV7 -0.18 0.18 8 AV8 +0.02 67 40 0.34 13 AV6 -0.02 0.18 9 AV7 -0.02 67 42 0.33 13 AV6 +0.00 0.32 13 AV7 +0.00 67 44 0.23 10 AV2 +0.05 67 46 0.29 12 AV6 +0.00 67 48 0.13 7 AV8 +0.02 67 50 0.51 17 AV3 +0.02 0.14 7 AV7 +0.00 67 52 0.23 10 AV3 +0.02 67 54 0.18 9 AV6 +0.02 67 58 0.23 10 AV6 +0.02 67 60 0.16 8 AV3 +0.00 67 62 0.14 7 AV6 +0.00 67 64 0.17 8 AV3 +0.02 0.14 7 AV6 +0.02 67 66 0.43 15 AV6 +0.00 67 68 0.17 8 AV2 +0.00 0.46 16 AV3 +0.03 0.34 13 AV6 +0.02 0.28 12 AV7 +0.02 67 70 0.25 11 AV3 +0.00 0.22 10 AV6 +0.05 67 74 0.40 15 AV3 +0.00 67 80 0.15 8 AV6 +0.00 67 88 0.14 7 AV2 -0.16 67 92 0.13 7 AV2 -0.14 0.16 8 AV3 +0.05 67 94 0.14 7 AV1 +0.00 0.29 12 AV2 +0.02 0.21 9 AV3 +0.00 67 96 0.12 6 AV2 +0.02 0.52 17 AV3 +0.03 0.24 11 AV7 +0.00 67 98 0.10 6 AV2 -0.05 0.20 9 AV3 +0.03 0.12 6 AV6 +0.23 67 100 0.07 4 AV7 +0.02 0.20 9 AV3 -0.02 0.32 13 AV6 +0.02 67 102 0.19 9 AV2 +0.02 67 104 0.49 17 AV2 +0.00 67 106 0.13 7 AV2 +0.02 0.17 8 AV3 +0.03 0.18 9 AV6 +0.02 0.32 13 AV7 +0.05 67 108 0.27 11 AV6 +0.02 0.26 11 AV2 +0.02 0.45 16 AV3 +0.02 67 110 0.17 8 AV2 +0.00 0.61 19 AV3 -0.03 0.59 19 AV6 +0.00 0.13 7 AV7 +0.00 67 112 0.38 14 AV2 +0.00 0.26 11 AV3 +0.05 0.27 11 AV6 +0.02 0.24 10 AV7 +0.05 67 114 0.16 8 AV3 +0.02 0.20 9 AV6 -0.05 0.22 10 AV7 +0.04 67 116 0.21 9 AV3 +0.02 0.27 11 AV6 +0.00 0.17 8 AV7 +0.02 0.20 9 AV2 +0.02 67 118 0.17 8 AV2 +0.02 0.13 7 AV3 +0.15 0.15 8 AV6 -0.03 0.19 9 AV7 +0.02 67 122 0.13 7 AV6 +0.16 67 128 0.19 9 AV3 -0.19 0.20 9 AV7 +0.02 67 130 0.13 7 AV3 +0.00 0.25 11 AV6 +0.18 67 132 0.22 10 AV2 +0.00 0.28 12 AV3 +0.10 67 134 0.38 14 AV6 -0.05 67 138 0.26 11 AV6 +0.00 67 140 0.22 10 AV6 -0.03 0.09 5 AV1 +0.41 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 23 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 8 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 67 142 0.12 6 AV8 -0.19 0.15 7 AV6 +0.19 0.28 12 AV3 +0.03 0.44 16 AV2 -0.02 67 144 0.36 14 AV6 -0.05 0.16 8 AV1 +0.16 67 146 0.58 18 AV6 -0.03 0.47 16 AV2 +0.00 0.33 13 AV1 +0.00 67 148 0.39 14 AV2 +0.00 0.19 9 AV1 +0.00 0.34 13 AV7 -0.02 67 150 0.20 9 AV3 +0.03 0.17 8 AV1 +0.00 67 152 0.21 9 AV7 +0.02 0.49 17 AV6 -0.02 0.17 8 AV2 +0.00 0.18 9 AV1 +0.21 67 154 0.54 18 AV7 +0.00 0.63 19 AV2 +0.02 0.23 10 AV1 +0.19 67 156 0.46 16 AV8 -0.16 0.20 9 AV6 -0.30 0.20 9 AV3 +0.25 0.31 12 AV2 +0.02 0.23 10 AV1 -0.23 67 158 0.22 10 AV8 +0.17 0.31 12 AV7 -0.02 0.51 17 AV6 -0.28 0.22 10 AV2 +0.16 0.17 8 AV1 -0.23 68 13 0.16 8 AV1 +0.23 0.20 9 AV3 +0.02 0.14 7 AV6 -0.25 0.08 5 AV7 -0.18 68 15 0.14 7 AV1 +0.16 68 17 0.15 8 AV1 +0.23 0.16 8 AV2 +0.20 0.13 7 AV3 +0.05 0.23 10 AV8 +0.02 68 19 0.10 6 AV1 +0.00 68 21 0.16 8 AV6 -0.16 68 35 0.21 9 AV6 +0.00 0.15 8 AV3 +0.00 68 45 0.19 9 AV3 +0.03 0.24 10 AV6 +0.00 68 55 0.20 9 AV3 +0.00 0.16 8 AV6 +0.00 68 59 0.16 8 AV6 +0.00 0.22 10 AV7 -0.02 68 61 0.12 6 AV8 -0.02 68 63 0.27 11 AV3 +0.00 0.13 7 AV6 +0.05 0.30 12 AV7 +0.02 68 65 0.11 6 AV6 +0.00 68 67 0.45 16 AV3 +0.00 0.36 14 AV7 +0.07 68 69 0.16 8 AV2 +0.05 0.19 9 AV3 +0.00 0.14 7 AV6 +0.02 68 71 0.22 10 AV2 +0.00 0.26 11 AV3 +0.02 68 77 0.33 13 AV6 +0.00 0.22 10 AV7 -0.02 68 79 0.12 6 AV3 +0.06 0.25 11 AV6 +0.00 68 81 0.13 7 AV3 -0.02 0.25 11 AV6 +0.02 68 87 0.11 6 AV2 -0.14 0.15 7 AV3 -0.14 0.15 7 AV7 +0.02 0.10 6 AV8 +0.00 68 89 0.39 14 AV6 +0.02 68 93 0.13 7 AV3 +0.03 68 95 0.15 7 AV6 +0.00 68 97 0.16 8 AV3 +0.03 0.20 9 AV6 +0.05 68 99 0.46 16 AV3 +0.05 0.20 9 AV7 +0.00 68 101 0.14 7 AV2 +0.00 0.24 10 AV3 +0.00 0.27 11 AV7 -0.02 68 103 0.14 7 AV2 -0.02 0.35 13 AV3 -0.05 0.38 14 AV7 +0.07 68 105 0.09 5 AV1 +0.19 0.12 6 AV2 +0.05 0.36 14 AV3 +0.00 0.17 8 AV6 +0.07 68 107 0.27 11 AV2 +0.00 0.18 9 AV3 +0.02 0.16 8 AV6 +0.00 68 109 0.15 7 AV6 +0.02 0.13 7 AV7 +0.02 68 111 0.42 15 AV3 +0.07 68 113 0.18 9 AV6 +0.00 0.37 14 AV7 +0.02 68 115 0.22 10 AV2 +0.00 0.34 13 AV8 +0.02 68 117 0.13 7 AV1 +0.02 0.17 8 AV3 +0.02 0.50 17 AV7 +0.00 68 119 0.22 10 AV6 -0.02 68 121 0.59 19 AV6 -0.02 68 123 0.27 11 AV6 +0.02 0.25 11 AV7 +0.04 68 125 0.25 11 AV6 +0.02 0.26 11 AV7 +0.00 68 133 0.13 7 AV2 +0.00 0.11 6 AV3 +0.05 68 135 0.21 10 AV2 -0.05 0.47 16 AV3 +0.02 0.59 19 AV6 -0.05 0.16 8 AV7 +0.00 68 139 0.17 8 AV3 +0.02 68 143 0.13 7 AV6 +0.11 0.09 5 AV1 +0.42 68 145 0.13 7 AV7 -0.02 0.35 13 AV6 -0.02 0.49 17 AV3 +0.00 68 147 0.15 7 AV3 +0.00 68 149 0.34 13 AV7 +0.00 68 151 0.27 11 AV6 -0.05 68 153 0.17 8 AV8 -0.19 0.61 19 AV7 -0.02 0.37 14 AV6 -0.05 0.38 14 AV3 +0.00 0.22 10 AV1 +0.19 68 155 0.22 10 AV1 -0.02 68 157 0.63 19 AV8 +0.19 0.57 18 AV3 +0.11 0.24 10 AV1 -0.23 69 14 0.13 7 AV1 -0.15 0.29 12 AV2 +0.00 0.29 12 AV3 +0.25 0.30 12 AV6 +0.02 69 16 0.15 8 AV7 +0.00 69 18 0.13 7 AV2 +0.22 0.12 6 AV3 +0.21 0.17 8 AV6 -0.21 69 36 0.13 7 AV3 +0.20 69 52 0.23 10 AV6 +0.02 0.26 11 AV7 +0.00 69 56 0.31 12 AV3 +0.02 69 60 0.15 8 AV7 +0.02 69 62 0.17 8 AV6 +0.00 69 66 0.36 14 AV3 +0.00 0.40 15 AV6 +0.07 69 68 0.19 9 AV2 +0.00 0.22 10 AV3 +0.00 0.15 8 AV6 +0.02 69 70 0.18 8 AV3 +0.00 0.33 13 AV6 -0.05 69 72 0.12 6 AV3 +0.02 0.24 10 AV6 +0.05 0.23 10 AV7 +0.02 69 74 0.30 12 AV2 +0.00 0.45 16 AV3 +0.06 0.52 13 AV4 +0.95 0.31 12 AV7 +0.00 69 76 0.12 6 AV3 +0.02 0.24 10 AV6 +0.02 69 86 0.21 9 AV6 +0.00 69 88 0.64 19 AV7 +0.00 69 90 0.20 9 AV2 -0.14 0.20 9 AV6 +0.05 69 92 0.20 9 AV3 +0.03 0.17 8 AV6 -0.02 69 94 0.21 10 AV6 +0.02 69 96 0.28 12 AV3 +0.00 0.26 11 AV6 +0.02 69 98 0.30 12 AV2 +0.05 0.36 14 AV3 +0.03 0.71 13 AV4 +0.45 0.40 15 AV6 +0.02 0.27 11 AV7 +0.02 69 100 0.14 7 AV2 +0.05 0.34 13 AV3 +0.03 0.58 18 AV7 +0.02 69 102 0.26 11 AV2 +0.05 0.29 12 AV3 +0.03 0.46 16 AV6 +0.02 0.20 9 AV7 -0.02 69 104 0.49 17 AV3 +0.03 69 106 0.11 6 AV2 +0.16 0.36 14 AV3 +0.00 0.29 12 AV7 +0.05 69 108 0.16 8 AV2 +0.00 0.19 9 AV8 +0.00 69 110 0.13 7 AV7 +0.00 0.34 13 AV6 +0.00 0.56 16 AV4 +0.87 69 112 0.26 11 AV6 +0.11 0.11 6 AV7 +0.02 69 114 0.35 13 AV1 +0.00 0.26 11 AV2 +0.02 0.27 11 AV3 +0.00 0.39 12 AV4 +0.02 0.24 10 AV6 -0.04 0.22 10 AV7 +0.02 0.26 11 AV8 +0.00 69 116 0.43 15 AV3 +0.03 0.57 18 AV6 +0.00 0.12 4 AV4 +0.65 69 118 0.07 4 AV2 +0.00 0.25 8 AV4 +0.91 0.12 6 AV6 -0.04 69 120 0.11 6 AV3 -0.05 0.26 8 AV4 +1.07 0.22 10 AV7 +0.00 69 122 0.12 6 AV3 +0.06 0.09 5 AV6 -0.22 0.23 7 AV4 +0.25 69 124 0.14 7 AV3 +0.00 0.17 5 AV4 +0.83 0.06 4 AV6 -0.38 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 24 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 9 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 69 126 0.15 4 AV4 +0.90 69 128 0.15 4 AV4 +0.91 69 130 0.20 7 AV4 +0.02 69 132 0.13 5 AV4 -0.08 69 134 0.53 17 AV6 -0.02 0.16 8 AV3 +0.12 69 136 0.21 7 AV4 +0.70 0.13 7 AV6 -0.05 69 138 0.14 7 AV6 +0.00 0.26 8 AV4 +0.74 69 140 0.07 5 AV8 +0.45 0.17 8 AV7 -0.19 0.08 5 AV1 +0.16 69 144 0.16 8 AV8 -0.21 0.27 10 AV4 +0.13 69 146 0.14 7 AV6 -0.04 0.13 7 AV2 +0.16 0.14 7 AV1 -0.02 69 150 0.17 8 AV2 +0.02 69 152 0.26 11 AV7 -0.05 0.47 16 AV6 -0.17 0.10 6 AV3 -0.07 0.12 6 AV1 +0.00 0.26 11 AV8 -0.18 69 154 0.40 15 AV8 +0.00 0.20 9 AV7 +0.00 0.44 16 AV3 +0.03 0.26 11 AV2 +0.00 0.34 13 AV1 +0.19 70 13 0.13 7 AV6 +0.00 70 15 0.27 11 AV1 +0.00 0.16 8 AV2 -0.12 0.20 9 AV6 +0.05 0.61 19 AV7 +0.00 0.35 13 AV8 +0.02 70 17 0.16 8 AV1 +0.02 0.22 10 AV2 +0.14 0.20 9 AV8 +0.05 70 35 0.11 6 AV4 -0.33 0.09 5 AV6 -0.15 70 45 0.13 7 AV5 -0.72 70 53 0.18 9 AV6 +0.02 0.21 10 AV7 +0.00 70 57 0.08 5 AV6 +0.16 70 59 0.11 6 AV6 +0.00 70 63 0.25 11 AV3 +0.00 0.39 14 AV6 +0.05 70 65 0.25 11 AV2 +0.00 0.39 14 AV3 +0.02 70 67 0.27 11 AV6 +0.02 0.25 11 AV7 +0.05 70 69 0.36 14 AV6 +0.02 0.23 10 AV7 +0.04 70 71 0.45 16 AV6 +0.02 0.19 9 AV7 +0.07 70 73 0.43 15 AV6 +0.02 0.24 10 AV7 +0.02 70 75 0.24 10 AV2 +0.00 0.12 6 AV3 +0.02 0.19 9 AV6 +0.07 0.26 11 AV7 +0.02 0.12 6 AV8 +0.00 0.21 10 AV5 -0.07 70 77 0.25 11 AV3 +0.00 0.33 13 AV6 +0.00 70 79 0.19 9 AV6 +0.02 70 83 0.11 6 AV2 -0.09 70 85 0.22 10 AV3 +0.02 0.35 13 AV6 +0.02 70 87 0.48 16 AV7 +0.00 0.12 6 AV2 -0.21 0.52 17 AV3 +0.02 0.21 9 AV4 +0.06 0.24 10 AV5 +0.06 0.17 8 AV6 +0.05 70 91 0.58 19 AV3 +0.04 0.56 18 AV6 +0.02 0.36 14 AV7 +0.00 0.31 12 AV2 +0.02 70 93 0.15 7 AV3 +0.02 0.12 6 AV6 +0.02 70 95 0.28 12 AV2 +0.00 0.33 13 AV3 +0.02 0.17 8 AV6 +0.05 70 97 0.55 18 AV3 +0.02 0.49 17 AV7 -0.02 70 99 0.17 8 AV6 +0.02 0.35 13 AV7 +0.00 0.17 8 AV8 +0.00 0.12 6 AV1 +0.00 0.27 11 AV2 +0.00 0.43 15 AV3 +0.02 0.17 8 AV5 +0.06 70 101 0.15 7 AV1 +0.00 0.41 15 AV2 +0.00 70 103 0.31 12 AV2 +0.05 0.29 12 AV3 +0.06 0.22 10 AV5 +0.37 0.59 19 AV6 +0.05 0.26 11 AV8 +0.02 70 105 0.49 17 AV6 +0.02 0.26 11 AV8 +0.02 0.12 6 AV1 +0.02 0.25 11 AV2 -0.05 70 107 0.18 8 AV2 -0.02 0.07 4 AV3 +0.02 0.41 15 AV6 +0.00 70 109 0.19 9 AV2 +0.02 0.55 18 AV3 +0.02 0.49 17 AV8 +0.02 0.15 7 AV5 +0.39 70 111 0.13 7 AV2 +0.00 0.33 13 AV6 +0.02 70 113 0.34 13 AV2 +0.00 0.08 5 AV3 +0.00 0.45 16 AV7 +0.00 70 115 0.21 9 AV2 +0.00 0.12 6 AV3 +0.00 0.23 10 AV6 +0.00 70 117 0.22 10 AV3 +0.02 0.16 8 AV6 +0.00 0.30 12 AV7 +0.02 0.17 8 AV2 +0.07 70 119 0.11 6 AV2 +0.00 0.33 13 AV6 +0.00 70 121 0.16 8 AV2 +0.02 0.18 9 AV3 -0.02 0.23 10 AV6 +0.00 70 123 0.15 7 AV3 +0.02 0.34 13 AV6 +0.00 70 129 0.22 10 AV6 -0.11 70 133 0.28 11 AV2 +0.02 0.47 16 AV6 -0.02 0.27 11 AV7 +0.02 70 135 0.09 5 AV6 +0.00 70 151 0.17 8 AV8 -0.16 0.24 11 AV7 -0.05 0.18 9 AV1 +0.14 70 153 0.20 9 AV8 -0.16 0.39 14 AV7 -0.02 0.21 9 AV6 -0.15 0.25 11 AV3 +0.14 0.22 10 AV1 +0.19 70 155 0.50 17 AV7 -0.12 0.39 14 AV6 -0.20 70 157 0.13 7 AV6 -0.04 0.28 12 AV3 -0.11 71 14 0.19 9 AV1 -0.17 0.22 10 AV2 +0.23 0.56 18 AV3 +0.12 0.36 14 AV6 -0.14 0.15 7 AV8 +0.21 71 16 0.08 5 AV1 -0.22 0.07 4 AV3 -0.12 0.45 16 AV7 -0.02 0.10 6 AV8 -0.11 71 18 0.17 8 AV4 +0.35 71 20 0.11 6 AV3 -0.20 71 26 0.09 5 AV7 -0.14 71 34 0.36 14 AV3 +0.00 0.17 8 AV6 +0.02 71 40 0.12 6 AV3 +0.00 71 44 0.12 6 AV5 +0.22 71 50 0.17 8 AV3 +0.02 71 62 0.09 5 AV2 +0.00 71 66 0.41 15 AV6 +0.05 0.11 6 AV5 -0.56 71 70 0.19 9 AV5 +0.02 0.40 15 AV6 -0.02 0.19 9 AV7 +0.00 71 72 0.14 7 AV4 +0.38 0.18 9 AV5 -0.13 0.53 18 AV6 +0.05 0.29 12 AV7 -0.02 71 74 0.15 8 AV3 +0.02 0.23 10 AV4 -0.04 0.17 8 AV5 +0.02 0.48 17 AV6 +0.02 0.52 17 AV7 +0.02 0.17 8 AV8 +0.02 71 76 0.25 11 AV3 +0.02 0.20 9 AV4 -0.02 0.43 15 AV5 +0.00 0.33 13 AV8 +0.00 71 78 0.29 12 AV2 +0.02 0.47 16 AV3 +0.04 0.19 9 AV4 +0.00 0.24 10 AV5 +0.06 0.18 8 AV7 +0.00 71 80 0.19 9 AV6 +0.02 71 84 0.16 8 AV3 +0.02 0.22 10 AV4 +0.00 71 88 0.15 8 AV2 -0.14 0.36 14 AV4 +0.00 0.25 11 AV5 -0.51 0.35 13 AV6 +0.00 0.30 12 AV7 +0.02 71 90 0.13 7 AV5 +0.06 0.23 10 AV7 +0.02 71 92 0.30 12 AV6 +0.02 0.23 10 AV2 +0.02 0.20 9 AV3 +0.02 0.32 13 AV4 +0.00 71 94 0.11 6 AV3 -0.16 0.25 11 AV5 +0.04 71 96 0.42 15 AV2 +0.02 0.19 9 AV3 +0.02 0.34 13 AV6 +0.02 0.29 12 AV7 +0.02 71 98 0.24 10 AV2 +0.02 0.36 14 AV3 +0.02 0.44 16 AV4 +0.04 0.48 16 AV6 +0.02 0.19 9 AV7 -0.02 71 100 0.14 7 AV2 +0.05 0.34 13 AV3 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 25 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 10 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.26 11 AV4 +0.00 0.33 13 AV6 +0.02 0.45 16 AV7 +0.00 71 102 0.21 10 AV1 +0.00 0.53 18 AV2 -0.02 0.26 11 AV5 +0.04 0.23 10 AV7 +0.02 71 104 0.11 6 AV3 +0.00 0.40 15 AV5 +0.02 0.38 14 AV7 -0.02 71 106 0.12 6 AV4 +0.48 0.17 8 AV5 -0.39 0.16 8 AV6 +0.07 0.13 7 AV7 +0.02 71 108 0.19 9 AV2 +0.00 0.14 7 AV5 -0.47 0.62 19 AV6 +0.02 0.52 17 AV7 +0.02 71 110 0.17 8 AV3 +0.06 71 112 0.17 8 AV2 +0.02 0.21 9 AV3 +0.04 0.29 12 AV4 +0.00 0.18 9 AV5 -0.32 71 114 0.16 8 AV4 -0.02 0.28 12 AV5 +0.02 0.43 15 AV6 -0.02 71 116 0.41 15 AV4 +0.47 0.20 9 AV6 +0.00 0.23 10 AV2 +0.05 0.58 18 AV3 +0.00 0.22 10 AV1 +0.00 71 118 0.14 7 AV4 +0.71 0.37 14 AV6 +0.00 0.33 13 AV7 +0.02 71 120 0.16 8 AV6 +0.00 71 138 0.26 11 AV3 +0.02 71 144 0.18 8 AV3 +0.14 71 148 0.13 7 AV8 +0.14 0.14 7 AV1 +0.02 71 150 0.20 9 AV1 +0.19 71 152 0.27 11 AV8 -0.02 0.17 8 AV7 -0.02 0.17 8 AV6 -0.16 0.17 8 AV1 +0.19 71 154 0.14 7 AV8 +0.19 0.16 8 AV2 -0.02 0.19 9 AV1 +0.23 71 156 0.33 13 AV8 +0.19 0.15 8 AV2 +0.16 72 15 0.38 14 AV5 -0.34 0.38 14 AV6 -0.17 0.35 14 AV7 -0.11 0.19 9 AV1 -0.10 0.22 10 AV2 -0.09 0.13 7 AV3 +0.24 72 17 0.17 8 AV5 +0.21 0.11 6 AV4 +0.38 0.21 9 AV2 +0.12 0.14 7 AV1 -0.18 72 25 0.42 15 AV3 +0.00 0.31 13 AV4 +0.26 0.62 19 AV5 +0.00 72 29 0.11 6 AV7 +0.02 72 31 0.14 7 AV8 +0.00 72 33 0.17 8 AV3 +0.02 0.14 7 AV4 +0.32 72 35 0.23 10 AV4 -0.17 0.11 6 AV5 +0.19 0.12 6 AV6 -0.19 72 37 0.11 6 AV7 +0.14 72 41 0.08 5 AV2 +0.19 72 53 0.19 9 AV6 +0.00 0.25 11 AV7 +0.00 72 57 0.20 9 AV6 +0.02 72 61 0.13 7 AV6 +0.02 0.22 10 AV7 +0.02 72 63 0.28 12 AV6 +0.02 72 65 0.18 8 AV3 +0.00 72 67 0.62 19 AV4 +0.00 0.52 17 AV7 +0.05 72 69 0.13 7 AV2 +0.02 0.12 6 AV3 +0.02 0.11 6 AV6 +0.19 0.23 10 AV7 +0.02 72 71 0.17 8 AV2 +0.00 0.40 15 AV3 +0.02 0.60 19 AV4 -0.02 0.45 16 AV5 +0.04 0.25 11 AV8 +0.00 72 73 0.10 6 AV2 +0.07 0.25 11 AV3 +0.00 0.40 15 AV4 -0.02 0.38 14 AV5 +0.02 0.56 18 AV6 -0.02 0.26 11 AV7 +0.00 72 75 0.16 8 AV1 +0.02 0.18 8 AV2 +0.02 0.20 9 AV3 +0.02 0.17 8 AV4 +0.00 0.44 16 AV5 +0.00 0.44 16 AV8 +0.00 72 77 0.24 10 AV2 +0.02 0.12 6 AV3 +0.00 0.19 9 AV4 +0.00 0.50 17 AV5 +0.04 0.56 18 AV6 +0.00 0.38 14 AV7 -0.02 72 79 0.46 16 AV2 -0.02 72 81 0.09 5 AV5 -0.35 72 83 0.13 7 AV3 +0.00 72 85 0.11 6 AV3 +0.00 0.18 8 AV4 -0.02 0.11 6 AV5 -0.29 0.12 6 AV6 +0.02 72 87 0.23 10 AV5 +0.04 72 89 0.45 16 AV3 -0.02 0.29 12 AV5 +0.06 0.17 8 AV7 +0.02 72 91 0.25 11 AV2 +0.02 0.54 18 AV4 +0.07 0.57 18 AV7 +0.00 0.33 13 AV8 +0.02 72 93 0.50 17 AV3 +0.02 0.49 17 AV5 +0.09 72 95 0.15 7 AV3 +0.02 0.33 13 AV4 +0.23 0.31 12 AV5 +0.05 0.45 16 AV6 +0.05 72 97 0.23 10 AV2 +0.00 0.17 8 AV3 +0.00 0.23 10 AV6 +0.00 72 99 0.32 13 AV2 +0.02 0.17 8 AV3 +0.04 0.26 11 AV6 +0.05 0.19 9 AV5 +0.06 72 101 0.19 9 AV2 -0.02 0.23 10 AV3 +0.02 0.32 13 AV4 +0.00 0.30 12 AV7 +0.00 72 103 0.31 12 AV2 +0.02 0.46 16 AV4 +0.04 0.26 11 AV8 +0.05 72 105 0.47 16 AV4 +0.00 0.23 10 AV6 +0.00 0.16 8 AV7 +0.05 0.16 8 AV2 -0.02 72 107 0.35 14 AV4 +0.04 0.33 13 AV5 +0.00 72 109 0.25 11 AV4 +0.04 0.35 14 AV7 +0.00 0.26 11 AV2 -0.02 0.58 18 AV3 +0.00 72 111 0.23 10 AV3 +0.02 0.17 8 AV4 +0.04 0.26 11 AV6 +0.02 0.21 10 AV7 +0.02 0.29 12 AV2 +0.02 72 113 0.16 8 AV3 +0.00 0.63 19 AV6 +0.00 0.37 14 AV7 +0.00 72 117 0.18 8 AV2 +0.02 0.12 6 AV5 +0.30 0.18 8 AV6 -0.02 72 119 0.11 6 AV2 +0.00 0.14 7 AV3 +0.02 0.11 6 AV6 -0.02 72 129 0.12 7 AV2 +0.05 72 139 0.16 8 AV5 -0.28 72 141 0.13 7 AV7 +0.16 0.16 8 AV3 -0.02 72 145 0.18 8 AV8 -0.22 72 147 0.09 5 AV6 -0.20 72 149 0.25 11 AV7 -0.05 0.49 17 AV6 -0.04 72 151 0.24 10 AV7 -0.02 0.29 12 AV6 -0.02 0.16 8 AV5 -0.04 0.29 12 AV3 +0.04 72 153 0.23 10 AV3 +0.14 0.24 10 AV1 -0.20 72 155 0.45 16 AV7 +0.00 0.21 9 AV5 +0.21 0.13 7 AV3 +0.15 0.27 11 AV1 -0.20 73 16 0.12 6 AV1 +0.19 0.24 10 AV2 -0.16 0.37 14 AV3 +0.02 0.17 8 AV4 +0.25 0.12 6 AV8 +0.18 73 18 0.24 11 AV1 +0.19 0.25 11 AV2 +0.25 0.53 18 AV8 +0.02 73 32 0.16 8 AV3 +0.02 73 44 0.15 7 AV4 -0.18 0.27 11 AV5 +0.24 0.08 5 AV8 +0.05 73 48 0.12 6 AV4 +0.21 73 54 0.16 8 AV3 +0.02 0.21 9 AV4 +0.00 0.16 8 AV5 +0.00 0.22 10 AV6 +0.00 0.20 9 AV7 +0.00 73 60 0.19 9 AV6 +0.00 0.20 9 AV7 +0.02 73 62 0.14 7 AV3 +0.00 0.22 10 AV4 -0.02 0.21 10 AV5 +0.02 0.20 9 AV6 +0.02 73 64 0.19 9 AV2 +0.05 73 66 0.22 10 AV4 +0.00 0.50 17 AV6 +0.05 73 68 0.25 11 AV4 +0.26 73 70 0.19 9 AV3 +0.00 0.20 9 AV5 +0.02 0.18 9 AV6 +0.00 0.16 8 AV7 +0.05 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 26 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 11 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 73 72 0.42 15 AV5 +0.04 73 74 0.16 8 AV2 +0.02 0.47 16 AV3 +0.02 0.43 15 AV8 +0.02 73 76 0.24 10 AV1 +0.00 0.26 11 AV2 +0.02 0.20 9 AV8 +0.02 73 78 0.14 7 AV3 +0.02 0.20 9 AV4 +0.00 0.27 11 AV5 -0.21 0.20 9 AV6 +0.02 73 80 0.17 8 AV3 +0.00 0.11 6 AV5 -0.19 0.20 9 AV6 -0.02 73 82 0.15 7 AV3 +0.02 0.19 9 AV4 +0.22 0.27 11 AV5 +0.00 0.32 13 AV6 +0.02 0.39 14 AV7 +0.02 73 84 0.13 7 AV7 +0.04 0.21 9 AV3 +0.02 0.32 13 AV4 -0.02 0.20 9 AV5 -0.15 73 86 0.44 16 AV4 -0.02 0.17 8 AV6 -0.02 73 88 0.19 9 AV2 +0.02 73 90 0.17 8 AV2 +0.00 0.31 12 AV5 +0.04 0.19 9 AV6 +0.05 0.26 11 AV7 +0.02 73 92 0.27 11 AV2 +0.00 0.29 12 AV3 +0.02 0.44 16 AV5 +0.05 0.40 15 AV6 +0.02 73 94 0.29 12 AV2 +0.02 0.30 12 AV3 +0.00 0.47 16 AV4 +0.03 0.30 12 AV7 +0.02 73 96 0.17 8 AV3 +0.02 0.51 17 AV7 +0.02 73 98 0.22 10 AV2 +0.00 0.42 15 AV4 -0.02 0.47 16 AV6 +0.05 0.30 12 AV7 +0.05 73 102 0.21 10 AV2 +0.02 0.28 11 AV3 +0.00 73 104 0.51 17 AV3 +0.02 0.60 19 AV4 +0.21 0.13 7 AV7 +0.00 0.34 13 AV2 +0.02 73 106 0.35 14 AV5 -0.25 0.17 8 AV6 +0.07 0.21 9 AV7 +0.07 0.18 8 AV8 +0.02 0.32 13 AV1 +0.02 73 108 0.17 8 AV2 +0.00 0.57 18 AV6 +0.00 0.25 11 AV7 +0.00 0.18 8 AV5 +0.09 73 110 0.44 16 AV5 +0.02 0.21 10 AV8 +0.02 73 112 0.09 5 AV1 -0.05 0.12 6 AV2 -0.02 0.50 17 AV4 +0.00 0.18 9 AV5 -0.13 73 114 0.15 7 AV5 +0.04 73 116 0.28 12 AV4 +0.23 0.26 11 AV6 -0.02 73 118 0.08 5 AV2 +0.21 0.13 7 AV3 +0.13 73 120 0.14 7 AV3 -0.05 73 134 0.17 8 AV3 +0.06 0.15 8 AV5 +0.02 0.27 11 AV6 +0.02 0.09 5 AV7 -0.16 73 136 0.12 6 AV3 +0.18 0.20 9 AV7 +0.02 73 138 0.14 7 AV7 +0.02 73 140 0.14 7 AV8 +0.14 0.10 6 AV6 -0.02 0.17 8 AV3 +0.02 73 144 0.15 7 AV3 +0.04 0.25 11 AV1 +0.00 73 152 0.17 8 AV7 -0.05 0.16 8 AV6 -0.16 0.18 9 AV4 +0.37 0.15 7 AV1 -0.21 73 154 0.24 10 AV8 -0.16 0.13 7 AV6 -0.04 0.36 14 AV3 +0.02 0.24 10 AV1 -0.23 74 15 0.11 6 AV7 -0.14 74 17 0.26 11 AV2 +0.13 0.15 7 AV3 +0.05 0.21 9 AV4 +0.29 0.14 7 AV5 +0.00 0.19 9 AV6 -0.16 0.19 9 AV7 +0.00 0.18 9 AV8 -0.16 0.17 8 AV1 +0.02 74 19 0.08 5 AV1 -0.23 0.13 7 AV2 +0.02 0.09 5 AV5 -0.03 0.13 7 AV6 +0.00 74 21 0.14 7 AV4 +0.23 0.17 8 AV8 +0.00 74 23 0.10 6 AV1 -0.12 0.13 7 AV4 +0.25 0.18 9 AV6 +0.00 74 25 0.09 5 AV5 +0.09 0.09 5 AV6 -0.18 0.20 9 AV7 -0.16 74 29 0.11 6 AV4 +0.28 74 33 0.19 9 AV4 +0.23 0.23 10 AV6 -0.02 0.18 9 AV7 +0.02 0.17 8 AV8 +0.02 74 35 0.23 10 AV3 +0.21 0.17 8 AV5 +0.02 0.17 8 AV6 -0.16 0.11 6 AV4 +0.00 74 55 0.36 14 AV4 +0.03 0.35 13 AV5 -0.14 0.26 11 AV6 +0.02 0.25 11 AV7 +0.00 74 57 0.17 8 AV5 -0.12 0.36 14 AV6 +0.02 74 59 0.16 8 AV6 +0.02 74 61 0.31 13 AV6 +0.05 0.16 8 AV7 +0.05 74 63 0.26 11 AV2 +0.02 0.16 8 AV3 +0.02 0.21 10 AV4 +0.03 0.26 11 AV5 +0.02 0.17 8 AV7 +0.02 74 65 0.13 7 AV2 +0.00 0.22 10 AV3 +0.02 0.14 7 AV5 +0.07 0.62 19 AV6 +0.02 0.23 10 AV7 -0.07 74 67 0.17 8 AV5 -0.28 0.36 14 AV8 +0.02 74 69 0.21 9 AV4 +0.00 0.13 7 AV5 -0.21 0.22 10 AV6 +0.02 0.32 13 AV7 +0.02 74 71 0.23 10 AV1 +0.00 0.18 9 AV2 +0.02 0.18 8 AV3 +0.02 74 73 0.12 6 AV1 +0.05 0.63 19 AV2 +0.05 0.14 7 AV8 +0.00 74 75 0.18 8 AV2 +0.00 0.59 19 AV3 +0.00 0.27 11 AV4 +0.00 0.56 18 AV5 +0.00 0.47 16 AV7 +0.00 74 77 0.28 12 AV4 +0.03 0.52 17 AV7 -0.02 74 79 0.24 10 AV4 +0.20 0.13 7 AV5 -0.17 0.38 14 AV6 +0.00 74 81 0.45 16 AV2 +0.00 0.41 15 AV7 +0.00 0.09 5 AV8 -0.02 74 83 0.35 13 AV6 +0.05 0.28 12 AV4 +0.03 0.46 16 AV5 +0.07 0.19 9 AV7 +0.00 0.19 9 AV2 +0.00 0.53 18 AV3 +0.02 74 85 0.17 8 AV3 +0.00 0.37 14 AV4 +0.00 0.30 12 AV5 -0.19 74 87 0.25 11 AV2 +0.02 0.54 18 AV7 +0.05 74 89 0.35 13 AV2 +0.00 74 91 0.14 7 AV2 +0.00 0.20 9 AV3 +0.00 0.20 9 AV4 +0.03 0.33 13 AV5 +0.05 74 93 0.44 16 AV3 +0.00 0.34 13 AV4 +0.06 0.53 18 AV6 +0.05 74 95 0.26 11 AV2 +0.00 0.44 16 AV3 +0.02 0.49 17 AV4 +0.24 74 97 0.34 13 AV2 +0.02 0.39 14 AV7 +0.00 74 99 0.20 9 AV1 +0.00 0.48 16 AV2 +0.02 0.22 10 AV3 +0.02 0.45 16 AV5 +0.02 0.33 13 AV6 +0.02 0.25 11 AV7 +0.00 74 101 0.15 7 AV1 +0.00 0.47 16 AV2 +0.00 0.43 15 AV3 -0.02 74 103 0.25 11 AV2 +0.02 0.11 6 AV4 +0.28 0.13 7 AV5 +0.02 0.21 9 AV6 +0.07 0.61 19 AV7 +0.00 0.40 15 AV8 +0.02 74 105 0.09 5 AV1 -0.02 0.13 7 AV2 -0.02 0.62 19 AV4 +0.00 0.16 8 AV5 +0.02 0.18 8 AV6 +0.02 0.32 13 AV7 +0.02 0.09 5 AV8 +0.05 74 107 0.25 11 AV2 +0.00 0.26 11 AV3 +0.02 0.35 14 AV4 +0.06 0.55 18 AV6 -0.02 0.15 7 AV7 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 27 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 12 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 74 111 0.20 9 AV3 +0.02 0.54 18 AV4 +0.03 0.54 18 AV7 +0.02 74 113 0.35 13 AV2 +0.02 0.11 6 AV3 +0.02 0.26 11 AV7 +0.00 74 115 0.30 12 AV4 +0.21 0.26 11 AV6 +0.02 0.34 13 AV7 +0.07 0.48 16 AV8 +0.02 74 117 0.25 11 AV2 +0.00 0.07 4 AV4 -0.18 74 119 0.20 9 AV2 +0.02 0.21 10 AV3 +0.04 74 123 0.18 8 AV5 +0.00 0.17 8 AV6 +0.02 74 125 0.30 12 AV7 +0.04 74 129 0.24 10 AV3 +0.00 74 137 0.14 7 AV2 -0.02 0.14 7 AV3 +0.00 0.14 7 AV5 -0.27 74 139 0.18 8 AV8 -0.18 0.16 8 AV5 -0.20 0.15 7 AV2 +0.00 74 141 0.09 5 AV7 +0.16 0.14 7 AV4 -0.04 0.16 8 AV3 +0.00 74 143 0.33 13 AV5 -0.30 74 145 0.54 18 AV1 -0.02 74 153 0.29 12 AV8 -0.16 0.13 7 AV5 -0.25 0.32 13 AV1 -0.23 75 16 0.13 7 AV2 +0.16 0.26 11 AV6 -0.02 0.19 9 AV7 -0.05 0.18 9 AV8 +0.18 75 18 0.45 16 AV4 +0.28 0.31 12 AV6 -0.05 0.21 10 AV2 +0.17 75 20 0.13 7 AV1 -0.20 75 28 0.11 6 AV5 +0.07 75 30 0.13 7 AV4 +0.23 75 44 0.11 6 AV4 -0.16 0.26 11 AV5 +0.18 0.14 7 AV7 +0.00 0.15 7 AV8 +0.05 75 52 0.19 9 AV2 +0.02 0.21 9 AV5 -0.17 75 54 0.13 7 AV6 +0.00 75 56 0.30 12 AV5 +0.05 0.30 12 AV6 +0.05 75 60 0.14 7 AV4 +0.20 0.08 5 AV7 +0.00 75 62 0.18 9 AV1 +0.02 0.37 14 AV4 +0.03 0.63 19 AV5 +0.02 0.44 16 AV6 +0.00 75 64 0.23 10 AV5 +0.02 75 66 0.49 17 AV4 +0.00 0.36 14 AV7 +0.02 75 68 0.21 9 AV5 -0.20 75 70 0.22 10 AV5 +0.02 0.38 14 AV6 +0.07 0.61 19 AV7 +0.02 0.21 10 AV8 +0.02 75 72 0.19 9 AV2 +0.02 0.27 11 AV3 -0.02 75 74 0.11 6 AV1 +0.00 0.16 8 AV3 +0.02 0.43 15 AV4 +0.03 0.55 18 AV5 +0.02 0.60 19 AV6 +0.02 0.37 14 AV7 +0.00 75 76 0.16 8 AV2 -0.02 0.50 17 AV3 +0.02 0.25 11 AV6 +0.02 75 78 0.61 19 AV3 +0.02 0.62 19 AV4 +0.06 0.52 17 AV5 +0.05 0.56 18 AV6 +0.05 0.25 11 AV7 +0.02 75 80 0.53 18 AV3 +0.02 0.62 19 AV6 +0.02 75 82 0.34 13 AV5 +0.00 0.24 10 AV6 +0.02 0.36 14 AV7 +0.02 75 84 0.25 11 AV3 +0.00 0.35 14 AV4 -0.02 0.21 10 AV5 -0.12 75 86 0.19 9 AV2 +0.00 0.42 15 AV4 +0.00 0.50 17 AV5 +0.00 75 88 0.35 13 AV3 +0.02 0.28 12 AV4 +0.14 0.60 19 AV5 +0.02 75 90 0.20 9 AV6 +0.02 0.24 11 AV7 +0.02 0.26 11 AV2 +0.00 0.24 10 AV3 +0.02 0.38 14 AV4 +0.03 0.57 18 AV5 +0.02 75 92 0.15 8 AV2 +0.02 0.23 10 AV3 +0.00 0.61 19 AV4 +0.06 0.55 18 AV5 +0.00 0.22 10 AV7 +0.02 75 94 0.26 11 AV2 +0.00 75 96 0.23 10 AV2 +0.00 0.49 17 AV3 +0.02 0.35 13 AV7 +0.02 75 98 0.49 17 AV2 +0.02 0.22 10 AV3 +0.02 0.50 17 AV6 +0.02 75 100 0.35 13 AV2 +0.02 0.58 18 AV3 +0.02 0.48 16 AV4 +0.06 0.33 13 AV5 -0.12 0.17 8 AV8 -0.02 75 104 0.63 19 AV4 +0.23 75 106 0.31 13 AV3 +0.00 75 108 0.16 8 AV2 +0.02 0.13 7 AV6 +0.00 0.26 11 AV7 +0.02 75 110 0.17 8 AV3 +0.07 0.26 11 AV4 +0.06 0.15 8 AV5 +0.02 0.27 11 AV6 +0.02 75 112 0.12 6 AV1 +0.05 0.21 10 AV2 +0.05 0.21 10 AV4 +0.03 0.31 12 AV6 +0.05 0.48 16 AV7 +0.04 0.32 13 AV8 +0.00 75 114 0.23 10 AV5 +0.00 75 116 0.29 12 AV7 +0.02 0.26 11 AV2 +0.02 0.34 13 AV3 +0.02 0.37 14 AV4 +0.25 0.38 14 AV6 -0.02 75 118 0.22 10 AV4 +0.23 0.20 9 AV5 +0.05 0.11 6 AV7 +0.05 75 120 0.16 8 AV6 -0.02 0.36 14 AV7 +0.00 75 124 0.24 10 AV5 -0.15 75 134 0.14 7 AV3 +0.04 75 140 0.13 7 AV6 -0.02 0.18 9 AV5 -0.31 75 142 0.19 9 AV5 -0.20 0.18 9 AV3 -0.02 75 144 0.22 10 AV8 +0.00 0.30 12 AV7 +0.00 0.15 8 AV6 +0.00 0.32 13 AV5 -0.20 75 146 0.13 7 AV5 -0.26 0.11 6 AV4 +0.17 0.22 10 AV3 +0.02 75 148 0.23 10 AV5 -0.26 75 150 0.15 7 AV6 +0.00 0.31 12 AV5 -0.26 0.27 11 AV3 +0.02 0.17 8 AV1 +0.00 75 152 0.26 11 AV8 -0.14 0.29 12 AV7 -0.05 0.12 6 AV4 +0.33 0.33 13 AV2 +0.00 0.23 10 AV1 -0.21 75 154 0.33 13 AV8 +0.21 0.23 10 AV7 -0.03 0.17 8 AV6 -0.02 0.22 10 AV3 +0.00 0.10 6 AV2 +0.00 0.28 12 AV1 -0.16 76 17 0.14 7 AV1 -0.16 0.22 10 AV2 +0.17 0.20 9 AV6 -0.16 0.17 8 AV7 +0.00 76 19 0.16 8 AV4 +0.22 0.16 8 AV6 -0.02 76 21 0.19 9 AV1 +0.05 0.28 12 AV4 +0.21 0.19 9 AV8 -0.02 76 27 0.13 7 AV1 +0.00 0.23 10 AV2 +0.07 0.15 7 AV5 -0.03 76 29 0.16 8 AV4 +0.27 0.19 9 AV6 +0.05 76 31 0.15 8 AV4 +0.21 76 33 0.18 9 AV4 +0.19 76 35 0.15 8 AV4 -0.19 76 41 0.10 6 AV5 -0.14 76 45 0.13 7 AV4 +0.30 76 55 0.11 6 AV4 -0.12 0.20 9 AV5 -0.19 76 59 0.46 16 AV2 +0.02 0.34 13 AV3 +0.00 0.11 6 AV7 +0.00 76 61 0.09 5 AV5 -0.19 0.38 14 AV6 +0.02 0.33 13 AV7 +0.04 76 63 0.26 11 AV3 +0.02 0.52 17 AV4 +0.03 0.44 16 AV5 -0.03 0.57 18 AV6 +0.02 0.22 10 AV7 +0.02 76 65 0.46 16 AV2 +0.00 0.21 10 AV3 +0.02 0.44 16 AV7 +0.09 76 67 0.26 11 AV7 +0.00 0.13 7 AV3 +0.02 0.19 9 AV5 -0.23 0.48 16 AV6 +0.00 76 69 0.11 6 AV3 +0.00 0.31 12 AV4 +0.03 0.08 5 AV5 -0.22 0.26 11 AV6 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 28 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 13 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.15 7 AV7 +0.02 76 71 0.47 16 AV2 +0.02 0.53 17 AV5 +0.05 0.52 17 AV6 +0.02 0.19 9 AV7 +0.04 76 73 0.25 11 AV3 +0.02 0.19 9 AV4 +0.06 0.30 12 AV6 +0.00 0.18 9 AV7 +0.00 76 75 0.59 19 AV2 +0.00 0.34 13 AV8 +0.02 76 77 0.18 9 AV2 +0.02 0.18 8 AV3 +0.02 0.24 10 AV4 +0.03 0.20 9 AV5 +0.00 0.63 19 AV6 +0.00 0.42 15 AV7 -0.02 76 79 0.12 6 AV2 +0.00 0.53 18 AV4 +0.03 0.23 10 AV5 +0.05 0.38 14 AV6 +0.02 76 81 0.40 15 AV2 +0.00 76 83 0.22 10 AV3 +0.02 0.22 10 AV5 +0.02 0.29 12 AV6 +0.02 0.34 13 AV7 +0.02 0.10 6 AV2 +0.00 76 85 0.20 9 AV3 +0.02 0.40 15 AV4 +0.06 0.27 11 AV5 +0.05 0.12 6 AV6 +0.02 76 87 0.16 8 AV2 +0.00 0.48 17 AV7 +0.02 76 89 0.32 13 AV2 -0.02 0.53 17 AV4 +0.00 0.18 9 AV7 +0.02 76 91 0.51 17 AV5 -0.17 0.17 8 AV2 +0.00 0.16 8 AV7 +0.05 0.39 14 AV3 +0.02 0.59 19 AV4 +0.03 76 93 0.18 9 AV2 +0.05 0.43 15 AV3 +0.00 0.16 8 AV4 +0.20 0.15 7 AV5 +0.07 76 95 0.18 8 AV2 +0.00 0.40 15 AV4 +0.20 0.29 12 AV5 +0.05 0.20 9 AV6 +0.02 0.47 16 AV7 +0.05 76 99 0.12 6 AV1 +0.02 0.56 18 AV3 +0.02 0.36 14 AV4 +0.19 0.18 8 AV8 +0.02 76 101 0.16 8 AV2 +0.00 0.22 10 AV3 -0.02 0.13 7 AV4 +0.06 0.45 16 AV6 +0.05 76 103 0.12 6 AV8 +0.05 0.15 7 AV3 +0.07 0.09 5 AV1 -0.07 76 105 0.54 18 AV2 +0.00 0.36 14 AV8 +0.05 76 107 0.24 10 AV7 +0.02 0.12 6 AV1 +0.02 0.26 11 AV2 +0.02 76 109 0.63 19 AV3 +0.02 0.11 6 AV2 +0.00 0.61 19 AV7 +0.02 0.45 16 AV4 +0.06 76 111 0.32 13 AV2 +0.07 0.60 19 AV3 +0.05 0.20 9 AV8 +0.00 76 113 0.56 18 AV6 +0.00 0.32 13 AV7 +0.02 0.13 7 AV8 -0.02 76 115 0.25 11 AV3 +0.02 0.18 8 AV7 +0.02 76 117 0.11 6 AV2 +0.00 0.30 12 AV4 +0.08 0.30 12 AV5 +0.02 0.18 8 AV6 -0.02 76 119 0.22 10 AV6 +0.02 76 121 0.24 10 AV5 -0.20 76 125 0.14 7 AV7 +0.02 76 137 0.12 6 AV2 -0.21 76 139 0.13 7 AV5 -0.24 76 143 0.38 14 AV5 -0.25 76 145 0.16 8 AV6 +0.00 0.27 11 AV5 -0.17 76 147 0.17 8 AV3 +0.02 0.56 18 AV2 +0.02 0.23 10 AV1 +0.00 0.19 9 AV5 -0.20 0.12 6 AV4 +0.17 76 151 0.26 11 AV2 +0.02 0.16 8 AV1 -0.18 76 153 0.40 15 AV8 -0.16 0.28 12 AV7 +0.00 0.28 12 AV5 -0.22 0.54 18 AV4 +0.03 0.24 10 AV3 +0.05 0.17 8 AV1 -0.20 77 16 0.12 6 AV1 -0.21 0.11 6 AV6 -0.16 77 18 0.15 7 AV1 +0.21 0.27 11 AV2 +0.21 0.22 10 AV5 -0.14 0.13 7 AV7 +0.00 77 20 0.12 6 AV4 +0.22 77 22 0.17 8 AV4 +0.25 77 26 0.07 4 AV1 +0.19 0.10 6 AV2 +0.02 0.11 6 AV3 +0.02 0.13 7 AV4 +0.00 77 30 0.11 6 AV4 +0.05 77 36 0.24 10 AV4 +0.24 77 44 0.16 8 AV5 +0.21 77 46 0.12 6 AV4 +0.19 77 50 0.09 5 AV5 -0.19 77 54 0.10 5 AV4 +0.24 0.31 12 AV6 +0.02 0.22 10 AV7 +0.00 77 56 0.32 13 AV4 +0.24 0.07 4 AV5 +0.14 0.09 5 AV6 +0.05 77 60 0.14 7 AV3 +0.00 0.20 9 AV4 +0.16 0.40 15 AV5 +0.02 0.43 15 AV6 +0.02 0.21 9 AV7 +0.00 77 62 0.10 6 AV3 +0.00 0.16 8 AV5 +0.02 77 64 0.40 15 AV5 +0.00 0.26 11 AV6 +0.02 0.32 13 AV7 +0.00 77 70 0.20 9 AV2 +0.00 0.40 15 AV3 +0.02 0.38 14 AV4 +0.03 0.22 10 AV5 +0.02 77 72 0.21 10 AV2 +0.02 0.18 8 AV3 +0.02 0.62 19 AV4 +0.03 0.29 12 AV7 +0.02 77 74 0.15 8 AV3 +0.02 0.49 17 AV7 +0.02 77 76 0.62 19 AV7 -0.02 0.10 5 AV1 +0.05 0.40 15 AV2 +0.00 77 78 0.51 17 AV3 +0.02 0.40 15 AV6 +0.02 77 80 0.19 9 AV2 +0.02 0.40 15 AV8 +0.00 77 82 0.20 9 AV4 +0.03 0.34 13 AV5 +0.00 0.13 7 AV6 +0.02 0.36 14 AV7 +0.00 0.12 6 AV3 +0.00 77 84 0.21 10 AV2 +0.00 0.22 10 AV3 +0.05 0.49 17 AV4 +0.03 0.34 13 AV5 +0.05 77 86 0.52 17 AV4 +0.00 0.53 18 AV5 -0.20 0.48 17 AV6 -0.02 0.34 13 AV7 +0.02 77 88 0.33 13 AV2 +0.02 0.27 11 AV3 +0.00 0.56 18 AV4 +0.05 0.33 13 AV5 +0.00 77 90 0.35 13 AV2 +0.05 0.57 18 AV7 +0.00 77 92 0.56 18 AV2 +0.02 77 94 0.39 14 AV2 +0.05 0.39 14 AV3 +0.02 0.59 19 AV7 +0.02 77 96 0.36 14 AV2 +0.00 0.34 13 AV3 +0.00 0.20 9 AV4 +0.06 0.54 18 AV5 +0.05 77 100 0.17 8 AV1 +0.00 0.22 10 AV2 +0.02 0.54 18 AV4 +0.03 0.20 9 AV8 +0.00 0.59 19 AV5 +0.02 77 102 0.45 16 AV7 -0.02 0.17 8 AV3 -0.02 77 104 0.17 8 AV1 +0.00 0.55 18 AV2 +0.00 0.54 18 AV4 +0.23 77 106 0.41 15 AV2 +0.02 0.39 14 AV7 +0.02 77 108 0.22 10 AV2 +0.02 0.30 12 AV7 +0.05 77 110 0.11 6 AV7 +0.02 0.13 7 AV8 +0.02 0.20 9 AV5 +0.00 0.26 11 AV6 +0.00 77 112 0.39 15 AV3 +0.02 0.25 11 AV8 +0.02 0.12 6 AV2 +0.05 77 114 0.35 13 AV3 +0.00 0.36 14 AV6 +0.00 0.48 16 AV7 +0.02 77 116 0.20 9 AV2 +0.05 77 118 0.20 9 AV3 -0.02 0.51 17 AV4 +0.22 0.49 17 AV5 +0.02 0.24 10 AV6 -0.02 0.08 5 AV7 -0.17 77 120 0.21 9 AV6 +0.00 77 122 0.09 5 AV4 +0.25 0.10 6 AV5 +0.26 0.46 16 AV6 +0.02 77 124 0.11 6 AV4 +0.03 0.18 8 AV5 -0.11 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 29 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 14 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.17 8 AV6 -0.05 77 130 0.14 7 AV6 +0.19 77 134 0.23 10 AV3 +0.07 0.13 7 AV4 +0.03 0.11 6 AV5 -0.16 77 138 0.40 15 AV5 -0.19 77 140 0.10 6 AV8 -0.14 0.14 7 AV5 -0.31 0.20 9 AV4 +0.00 77 142 0.14 7 AV5 +0.01 77 144 0.25 11 AV5 -0.22 77 146 0.11 6 AV5 -0.17 0.43 15 AV3 +0.02 0.30 12 AV2 +0.00 0.23 10 AV1 +0.02 77 148 0.14 7 AV1 -0.18 77 152 0.22 10 AV8 +0.19 0.20 9 AV7 -0.05 0.23 10 AV6 -0.05 0.19 9 AV2 +0.00 77 154 0.21 10 AV1 -0.16 78 17 0.14 7 AV1 -0.19 0.23 10 AV2 +0.17 0.18 9 AV8 +0.18 0.17 8 AV6 -0.14 78 21 0.13 7 AV8 -0.02 78 23 0.16 8 AV4 +0.08 78 31 0.13 7 AV5 +0.00 78 35 0.13 7 AV5 +0.18 78 45 0.36 14 AV4 +0.24 78 47 0.09 5 AV4 +0.05 78 49 0.18 8 AV4 -0.16 0.14 7 AV5 +0.16 78 53 0.34 13 AV5 -0.03 0.37 14 AV6 +0.02 78 55 0.14 7 AV6 +0.00 78 57 0.20 9 AV5 +0.02 0.24 10 AV6 +0.00 78 59 0.22 10 AV6 +0.00 0.34 13 AV7 +0.00 78 61 0.54 18 AV6 +0.02 78 63 0.17 8 AV1 +0.02 0.20 9 AV2 +0.05 0.37 14 AV3 +0.05 0.33 13 AV4 +0.03 0.19 9 AV5 +0.02 0.41 15 AV6 +0.05 78 67 0.13 7 AV3 +0.02 0.45 16 AV5 +0.05 0.42 15 AV7 +0.02 78 69 0.16 8 AV1 +0.00 0.26 11 AV2 +0.00 0.24 10 AV7 +0.05 0.23 10 AV8 -0.02 78 71 0.32 13 AV1 +0.02 0.40 15 AV2 +0.00 0.29 12 AV3 +0.00 0.44 16 AV4 +0.00 0.21 9 AV5 +0.02 0.50 17 AV7 +0.02 78 73 0.19 9 AV2 -0.05 0.58 19 AV4 +0.00 78 75 0.32 13 AV2 +0.00 0.52 17 AV4 +0.03 78 77 0.53 17 AV3 +0.00 0.47 16 AV7 +0.05 0.35 14 AV2 +0.02 78 79 0.18 8 AV3 +0.05 0.49 17 AV7 +0.00 78 81 0.17 8 AV3 +0.02 0.14 7 AV5 +0.02 0.18 8 AV6 +0.00 78 83 0.11 6 AV1 -0.19 0.17 8 AV2 -0.02 0.53 18 AV3 +0.00 0.50 17 AV4 -0.02 0.61 19 AV7 +0.00 78 85 0.19 9 AV3 +0.02 0.44 16 AV4 +0.00 0.38 14 AV5 +0.02 0.20 9 AV6 +0.07 78 87 0.17 8 AV2 -0.02 0.60 19 AV3 +0.02 0.38 14 AV7 +0.02 78 91 0.35 13 AV4 +0.03 0.16 8 AV5 -0.17 0.47 16 AV6 +0.05 78 93 0.30 12 AV3 -0.02 0.35 13 AV4 +0.06 0.21 9 AV5 +0.07 0.13 7 AV2 +0.00 78 95 0.57 18 AV7 +0.07 0.12 6 AV1 +0.05 0.37 14 AV2 +0.00 78 97 0.23 10 AV2 -0.02 78 101 0.32 13 AV2 +0.00 0.35 13 AV3 +0.02 0.34 13 AV7 +0.02 78 107 0.18 8 AV2 +0.02 0.52 17 AV3 +0.02 0.43 15 AV5 +0.05 0.18 9 AV7 +0.05 0.13 7 AV8 +0.02 78 111 0.11 6 AV7 +0.16 0.22 10 AV3 +0.05 78 113 0.26 11 AV2 +0.02 0.61 19 AV5 +0.02 0.62 19 AV7 +0.02 78 115 0.17 8 AV4 +0.03 0.35 14 AV5 -0.22 0.55 18 AV6 +0.00 0.16 8 AV7 +0.00 0.23 10 AV8 +0.00 0.43 15 AV3 +0.02 78 121 0.34 13 AV5 +0.02 78 123 0.19 9 AV3 +0.02 0.15 7 AV5 +0.14 78 125 0.48 16 AV6 +0.02 0.31 12 AV7 +0.00 0.11 6 AV8 +0.05 78 133 0.20 9 AV3 +0.00 78 137 0.21 9 AV5 -0.22 78 139 0.17 8 AV5 -0.16 0.13 7 AV3 +0.00 78 143 0.33 13 AV5 -0.22 0.17 8 AV3 -0.02 78 145 0.21 10 AV5 -0.25 0.27 11 AV2 -0.02 78 147 0.15 7 AV4 +0.00 78 149 0.16 8 AV8 +0.12 0.30 12 AV7 -0.02 78 151 0.20 9 AV3 +0.00 0.15 7 AV2 +0.02 0.20 9 AV1 -0.20 78 153 0.25 11 AV8 +0.14 0.62 19 AV7 -0.02 0.23 10 AV6 -0.07 0.13 7 AV5 +0.00 0.17 8 AV3 +0.21 0.13 7 AV2 +0.16 0.46 16 AV1 -0.23 79 18 0.16 8 AV1 +0.21 0.12 7 AV2 +0.22 0.16 8 AV3 +0.05 0.15 8 AV5 -0.16 0.16 8 AV6 -0.19 79 20 0.13 7 AV1 -0.16 0.18 8 AV2 +0.05 0.12 6 AV4 +0.19 0.17 8 AV7 +0.02 0.13 7 AV8 +0.02 79 22 0.18 9 AV2 +0.02 0.21 9 AV4 +0.00 0.14 7 AV7 +0.05 79 24 0.15 7 AV4 +0.05 0.15 8 AV7 +0.00 79 30 0.13 7 AV1 +0.02 0.26 11 AV2 +0.00 0.14 7 AV4 -0.02 79 34 0.09 5 AV5 +0.18 79 36 0.23 10 AV4 +0.21 79 46 0.22 10 AV1 -0.03 0.12 6 AV4 +0.00 79 50 0.13 7 AV4 +0.27 79 56 0.18 9 AV6 +0.02 79 60 0.18 9 AV6 -0.02 0.20 9 AV7 +0.00 0.19 9 AV8 +0.02 79 62 0.47 16 AV4 +0.03 0.38 14 AV6 +0.02 79 64 0.30 12 AV5 +0.02 79 66 0.16 8 AV6 +0.02 79 68 0.37 14 AV3 +0.00 0.55 18 AV5 +0.07 79 70 0.16 8 AV3 +0.00 0.45 16 AV7 +0.00 79 72 0.39 15 AV3 +0.05 0.63 19 AV4 +0.03 79 74 0.25 11 AV2 +0.05 0.46 16 AV3 +0.02 0.32 13 AV8 +0.02 79 76 0.21 9 AV1 +0.00 0.13 7 AV2 +0.05 0.32 13 AV3 +0.02 0.22 10 AV8 +0.00 79 78 0.40 15 AV8 +0.02 0.22 10 AV2 +0.00 0.45 16 AV3 +0.02 79 82 0.33 13 AV3 +0.00 0.62 19 AV6 -0.02 0.34 13 AV7 +0.02 79 84 0.10 6 AV3 +0.00 0.11 6 AV4 +0.03 0.13 7 AV5 +0.02 0.15 7 AV6 +0.02 79 86 0.20 9 AV2 +0.02 0.59 19 AV5 +0.02 0.28 12 AV6 +0.07 0.28 11 AV7 +0.02 79 88 0.22 10 AV4 +0.03 0.27 11 AV5 +0.00 79 90 0.27 11 AV2 +0.02 0.61 19 AV3 +0.00 0.27 11 AV4 +0.03 0.41 15 AV5 +0.05 0.54 18 AV7 +0.05 79 92 0.40 15 AV2 +0.00 0.59 19 AV7 +0.05 79 94 0.41 15 AV2 +0.02 0.33 13 AV8 +0.00 79 96 0.53 18 AV2 +0.00 0.23 10 AV3 +0.00 0.22 10 AV7 +0.05 0.20 9 AV8 +0.02 79 102 0.20 9 AV2 +0.02 0.20 9 AV7 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 30 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 15 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 79 104 0.36 14 AV1 +0.00 0.61 19 AV4 +0.06 0.34 13 AV7 +0.05 0.39 14 AV8 +0.02 79 106 0.24 10 AV2 +0.02 0.54 18 AV7 +0.02 79 108 0.16 8 AV1 +0.00 0.23 10 AV2 +0.02 0.61 19 AV5 +0.00 0.27 11 AV8 +0.05 79 110 0.56 18 AV2 +0.02 0.09 5 AV4 +0.08 0.14 7 AV5 +0.23 0.41 15 AV6 +0.02 0.32 13 AV7 +0.02 79 112 0.18 9 AV2 +0.00 0.21 9 AV4 +0.03 0.27 11 AV5 +0.00 0.24 10 AV6 +0.05 79 114 0.30 12 AV3 +0.05 0.34 13 AV6 +0.02 0.25 11 AV7 +0.02 79 116 0.14 7 AV3 +0.02 0.17 8 AV1 +0.02 0.17 8 AV2 +0.05 0.20 9 AV5 +0.19 79 118 0.12 6 AV2 +0.05 0.35 13 AV5 +0.19 0.56 18 AV6 -0.02 0.34 13 AV7 +0.05 79 130 0.13 7 AV6 +0.05 79 132 0.14 7 AV2 +0.02 0.22 10 AV7 -0.02 79 134 0.29 12 AV3 +0.04 0.16 8 AV4 +0.06 0.28 12 AV5 +0.07 0.22 10 AV6 +0.02 0.14 7 AV7 -0.05 79 138 0.20 9 AV5 -0.20 0.16 8 AV2 -0.02 79 144 0.16 8 AV5 -0.19 79 146 0.19 9 AV8 -0.14 0.19 9 AV3 -0.02 79 148 0.16 8 AV3 -0.05 79 150 0.16 8 AV3 +0.02 79 152 0.13 7 AV8 +0.19 80 19 0.17 8 AV1 -0.17 80 21 0.17 8 AV1 +0.02 0.15 7 AV4 +0.11 80 25 0.16 8 AV6 -0.19 80 27 0.08 5 AV1 +0.00 0.06 4 AV2 +0.05 0.09 5 AV4 +0.21 80 29 0.15 8 AV4 +0.19 80 31 0.11 6 AV4 +0.21 80 33 0.14 7 AV4 +0.13 80 35 0.20 9 AV4 -0.14 0.17 8 AV5 +0.19 80 41 0.18 8 AV3 +0.02 80 43 0.13 7 AV3 +0.00 80 45 0.24 10 AV4 +0.24 80 51 0.24 10 AV5 +0.00 80 59 0.15 8 AV5 +0.05 80 61 0.29 12 AV5 +0.00 0.58 18 AV6 +0.02 0.26 11 AV4 +0.03 80 67 0.15 7 AV3 +0.00 0.37 14 AV4 +0.03 0.48 16 AV7 +0.00 0.33 13 AV8 +0.05 80 69 0.08 5 AV1 -0.05 0.25 11 AV8 +0.02 80 73 0.35 13 AV3 +0.00 0.63 19 AV7 -0.02 80 75 0.15 7 AV3 +0.05 0.18 9 AV2 +0.00 80 77 0.30 12 AV2 +0.02 0.13 7 AV7 -0.05 80 79 0.37 14 AV4 +0.03 0.44 16 AV6 +0.00 80 81 0.21 9 AV3 +0.00 0.22 10 AV4 +0.03 0.14 7 AV5 -0.03 0.26 11 AV6 +0.02 0.54 18 AV7 +0.00 0.13 7 AV8 +0.05 80 83 0.20 9 AV2 +0.00 0.46 16 AV3 +0.02 0.63 19 AV4 +0.03 80 85 0.37 14 AV5 +0.02 0.48 17 AV7 +0.00 0.33 13 AV3 +0.05 0.27 11 AV4 +0.03 80 87 0.21 9 AV2 +0.02 80 91 0.16 8 AV2 +0.02 0.38 14 AV4 -0.15 0.44 16 AV5 +0.05 0.10 6 AV7 +0.05 80 93 0.27 11 AV3 +0.00 0.38 14 AV7 +0.02 80 95 0.18 9 AV2 +0.00 0.33 13 AV7 +0.02 80 99 0.54 18 AV2 +0.00 0.30 12 AV3 +0.00 0.32 13 AV4 +0.00 80 101 0.58 18 AV7 -0.02 0.28 12 AV8 +0.02 0.26 11 AV1 +0.00 80 105 0.49 17 AV2 -0.02 0.22 10 AV3 +0.00 0.22 10 AV4 -0.17 0.12 6 AV6 -0.12 0.35 13 AV7 +0.05 80 107 0.20 9 AV2 -0.02 0.49 17 AV3 +0.00 0.39 14 AV4 +0.03 0.62 19 AV5 +0.02 0.42 15 AV7 +0.05 80 111 0.17 8 AV2 +0.07 0.37 14 AV3 +0.07 0.18 8 AV7 +0.02 80 113 0.34 13 AV2 +0.02 0.29 12 AV3 +0.02 0.50 17 AV4 +0.03 0.45 16 AV5 +0.02 0.27 11 AV6 -0.05 80 115 0.23 10 AV1 +0.00 0.23 10 AV2 +0.05 0.43 15 AV3 +0.02 0.24 10 AV8 +0.00 80 117 0.17 8 AV3 +0.00 0.28 12 AV4 +0.08 0.22 10 AV8 +0.02 80 121 0.17 8 AV5 +0.05 80 123 0.19 9 AV5 +0.05 80 125 0.14 7 AV2 +0.17 0.14 7 AV3 +0.05 80 133 0.22 10 AV2 +0.00 0.24 10 AV5 -0.03 80 135 0.24 10 AV2 +0.02 0.14 7 AV4 +0.00 80 137 0.30 12 AV5 -0.24 0.27 11 AV3 -0.02 80 145 0.12 6 AV6 +0.00 0.15 7 AV5 -0.03 0.10 5 AV1 +0.16 80 147 0.08 5 AV8 +0.19 80 149 0.18 8 AV8 +0.12 0.15 7 AV4 +0.00 81 18 0.11 6 AV1 -0.14 0.11 6 AV8 +0.18 81 22 0.16 8 AV4 -0.02 81 26 0.07 4 AV5 -0.16 81 32 0.16 8 AV4 +0.16 0.13 7 AV7 +0.00 81 34 0.14 7 AV3 +0.00 0.12 6 AV4 +0.00 0.11 6 AV5 +0.16 81 36 0.28 12 AV4 +0.18 0.18 8 AV5 -0.21 81 38 0.13 7 AV4 +0.05 81 40 0.16 8 AV4 +0.21 81 44 0.13 7 AV2 +0.05 81 46 0.13 7 AV2 -0.02 0.21 10 AV4 +0.03 81 50 0.22 10 AV4 +0.24 81 52 0.20 9 AV4 +0.21 81 54 0.16 8 AV6 +0.00 81 56 0.13 7 AV4 +0.16 81 58 0.17 8 AV6 +0.00 81 60 0.17 8 AV7 +0.00 81 64 0.26 11 AV3 +0.00 0.16 8 AV5 +0.00 0.38 14 AV6 +0.00 81 66 0.20 9 AV2 +0.00 0.27 11 AV3 +0.02 0.26 11 AV4 +0.05 0.35 13 AV7 +0.00 81 68 0.14 7 AV3 +0.02 0.17 8 AV4 +0.03 81 70 0.20 9 AV1 +0.00 0.35 14 AV4 +0.03 0.61 19 AV7 +0.02 0.18 8 AV8 +0.02 81 74 0.40 15 AV2 +0.00 0.25 11 AV3 +0.00 0.42 15 AV5 +0.00 0.54 18 AV7 +0.02 81 76 0.12 6 AV1 +0.00 0.19 9 AV2 +0.02 0.53 17 AV3 +0.00 0.25 11 AV6 +0.02 0.57 18 AV7 +0.02 81 80 0.12 6 AV3 +0.00 0.21 9 AV4 +0.00 0.54 18 AV5 +0.02 81 82 0.35 13 AV2 +0.02 81 84 0.21 9 AV3 +0.00 0.14 7 AV4 +0.06 0.18 9 AV5 +0.02 0.44 16 AV6 +0.05 0.17 8 AV1 +0.02 81 86 0.13 7 AV2 -0.02 0.26 11 AV3 +0.05 0.15 7 AV5 -0.03 0.51 17 AV7 +0.02 81 88 0.16 8 AV2 +0.02 81 90 0.27 11 AV2 +0.00 0.14 7 AV4 +0.00 0.54 18 AV6 +0.05 0.29 12 AV7 +0.07 81 92 0.50 17 AV2 +0.02 0.31 12 AV4 +0.19 0.35 14 AV7 +0.02 81 94 0.54 18 AV6 +0.02 0.51 17 AV7 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 31 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 16 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.16 8 AV1 +0.00 0.42 15 AV2 +0.02 81 96 0.17 8 AV2 -0.02 0.41 15 AV3 +0.02 0.30 12 AV7 +0.05 81 100 0.16 8 AV1 +0.00 0.44 16 AV2 +0.02 81 102 0.18 9 AV1 +0.02 0.28 12 AV2 +0.02 0.61 19 AV3 +0.02 0.60 19 AV5 +0.02 81 106 0.45 16 AV3 +0.05 0.60 19 AV5 +0.00 0.18 9 AV6 +0.02 0.13 7 AV7 +0.18 0.13 7 AV1 +0.00 0.33 13 AV2 +0.02 81 108 0.40 15 AV2 +0.02 0.47 16 AV4 +0.03 0.48 16 AV6 +0.05 0.17 8 AV7 +0.05 81 110 0.19 9 AV3 +0.00 0.63 19 AV4 +0.00 0.46 16 AV6 +0.02 0.33 13 AV7 +0.02 81 112 0.14 7 AV2 -0.16 0.33 13 AV3 +0.05 0.11 6 AV4 +0.03 0.18 9 AV6 +0.18 81 114 0.10 6 AV1 -0.02 0.29 12 AV2 +0.02 0.41 15 AV3 +0.00 0.40 15 AV6 +0.00 81 116 0.36 14 AV2 +0.05 0.36 14 AV4 +0.05 0.52 17 AV5 +0.02 0.63 19 AV6 -0.02 0.23 10 AV7 +0.04 81 118 0.22 10 AV5 +0.05 81 122 0.15 7 AV3 +0.00 81 128 0.14 7 AV3 -0.02 0.10 5 AV5 -0.14 81 130 0.13 7 AV5 -0.16 81 132 0.24 10 AV3 +0.05 0.32 13 AV5 +0.00 0.60 19 AV7 +0.02 81 134 0.17 8 AV2 +0.02 0.21 9 AV3 +0.02 0.16 8 AV4 +0.05 81 138 0.14 7 AV5 -0.19 0.12 6 AV3 +0.00 81 140 0.08 5 AV8 -0.21 0.12 6 AV4 +0.13 81 146 0.17 8 AV4 +0.00 0.15 7 AV1 -0.21 81 148 0.19 9 AV8 +0.16 0.30 12 AV7 +0.00 0.13 7 AV5 -0.06 0.13 7 AV3 -0.02 0.16 8 AV1 -0.18 81 150 0.15 7 AV1 -0.21 81 152 0.13 7 AV1 -0.20 82 19 0.12 6 AV1 -0.17 82 25 0.10 6 AV3 -0.02 82 27 0.11 6 AV4 +0.13 0.12 6 AV5 +0.00 82 35 0.11 6 AV4 -0.19 0.23 10 AV5 +0.19 0.25 11 AV6 +0.00 0.15 7 AV7 -0.02 0.12 6 AV3 +0.02 82 41 0.11 6 AV3 +0.02 82 45 0.19 9 AV4 +0.21 82 53 0.16 8 AV6 +0.00 82 55 0.17 8 AV4 -0.14 82 59 0.09 5 AV4 +0.03 0.18 9 AV6 +0.02 0.33 13 AV7 +0.00 82 65 0.20 9 AV6 +0.02 82 67 0.48 16 AV1 +0.02 82 77 0.21 10 AV2 +0.00 0.44 16 AV3 +0.02 0.14 7 AV4 +0.00 0.53 18 AV8 +0.00 82 79 0.60 19 AV2 +0.00 0.10 6 AV8 +0.00 82 81 0.17 8 AV2 +0.02 0.49 17 AV3 +0.02 0.48 16 AV4 +0.03 82 83 0.20 9 AV2 +0.00 0.29 12 AV3 +0.05 82 85 0.11 6 AV2 -0.02 0.20 9 AV3 +0.02 82 87 0.27 11 AV3 +0.00 0.43 15 AV5 +0.05 0.23 10 AV6 +0.05 82 91 0.14 7 AV2 +0.00 0.42 15 AV7 +0.00 82 93 0.11 6 AV1 +0.05 0.20 9 AV2 +0.00 0.31 12 AV3 +0.02 82 95 0.21 9 AV1 +0.02 82 97 0.15 7 AV1 +0.02 0.60 19 AV2 +0.00 0.21 9 AV3 +0.05 82 99 0.45 16 AV3 +0.02 0.63 19 AV8 +0.00 82 107 0.37 14 AV3 +0.02 0.24 10 AV5 +0.05 0.18 8 AV2 +0.02 82 109 0.37 14 AV7 +0.05 0.27 11 AV8 +0.05 0.21 10 AV1 -0.02 0.33 13 AV2 +0.00 0.49 17 AV3 +0.02 82 111 0.28 12 AV4 +0.08 0.17 8 AV5 +0.07 0.55 18 AV6 +0.05 0.16 8 AV7 +0.05 0.15 7 AV2 +0.05 82 113 0.15 7 AV2 +0.05 0.19 9 AV3 +0.05 0.11 6 AV5 +0.05 0.21 10 AV8 +0.05 82 115 0.19 9 AV3 +0.02 0.20 9 AV4 +0.05 82 117 0.25 11 AV3 +0.02 0.53 18 AV4 +0.05 0.44 16 AV7 +0.02 82 123 0.12 6 AV5 +0.19 0.14 7 AV7 +0.05 82 127 0.15 7 AV2 +0.00 0.16 8 AV3 +0.02 0.11 6 AV4 -0.02 0.09 5 AV5 +0.00 82 131 0.25 11 AV2 +0.02 82 133 0.24 11 AV3 +0.00 0.23 10 AV4 +0.08 0.46 16 AV5 +0.02 0.13 7 AV6 +0.00 82 135 0.16 8 AV2 +0.05 82 137 0.12 6 AV5 -0.19 0.17 8 AV3 +0.02 82 139 0.15 7 AV5 -0.22 0.18 9 AV4 -0.02 82 141 0.13 7 AV2 -0.19 82 143 0.16 8 AV3 +0.02 82 149 0.15 8 AV3 -0.02 83 20 0.16 8 AV1 -0.17 0.14 7 AV2 +0.05 83 26 0.12 6 AV3 +0.05 0.13 7 AV5 -0.03 83 36 0.20 9 AV4 +0.23 83 38 0.15 7 AV5 +0.00 83 40 0.10 6 AV5 +0.00 83 46 0.13 7 AV4 +0.23 83 50 0.29 12 AV4 +0.16 83 60 0.26 11 AV6 +0.02 0.27 11 AV7 +0.00 83 62 0.17 8 AV7 +0.02 0.17 8 AV2 +0.00 0.19 9 AV5 +0.02 83 64 0.31 12 AV4 +0.03 0.23 10 AV8 +0.09 83 66 0.17 8 AV4 +0.00 0.09 5 AV3 +0.02 83 68 0.11 6 AV3 +0.00 0.43 15 AV4 +0.03 83 70 0.16 8 AV3 +0.02 0.16 8 AV5 +0.21 0.23 10 AV1 +0.00 0.54 18 AV6 +0.05 83 72 0.26 11 AV2 +0.00 0.57 18 AV3 +0.02 0.61 19 AV4 +0.03 0.48 17 AV8 +0.02 83 74 0.16 8 AV2 +0.00 0.57 18 AV3 +0.00 0.62 19 AV4 +0.03 83 78 0.12 6 AV2 +0.00 0.64 19 AV3 +0.02 83 80 0.21 9 AV3 +0.05 0.26 11 AV8 +0.00 83 82 0.31 12 AV3 +0.00 0.22 10 AV4 +0.03 0.20 9 AV6 +0.02 0.37 14 AV7 +0.05 83 84 0.17 8 AV2 +0.00 0.57 18 AV4 +0.03 0.60 19 AV7 +0.02 83 86 0.35 14 AV3 +0.02 0.16 8 AV4 +0.05 83 88 0.16 8 AV2 +0.02 0.25 11 AV3 +0.00 83 92 0.39 14 AV2 +0.02 0.28 12 AV8 +0.02 83 96 0.34 13 AV2 +0.02 83 100 0.25 11 AV1 +0.00 0.55 18 AV2 +0.02 0.38 14 AV3 +0.02 83 106 0.27 11 AV2 +0.00 0.26 11 AV3 +0.02 83 108 0.11 6 AV7 +0.02 83 110 0.23 10 AV3 +0.05 0.50 17 AV6 +0.02 0.30 12 AV7 +0.05 83 112 0.26 11 AV2 +0.05 0.53 18 AV3 +0.02 0.26 11 AV6 +0.07 0.52 17 AV5 +0.02 83 114 0.14 7 AV1 +0.02 0.27 11 AV2 +0.02 0.25 11 AV4 +0.05 83 116 0.24 11 AV2 +0.05 0.16 8 AV5 -0.14 0.30 12 AV7 +0.05 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 32 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 17 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 83 122 0.12 6 AV6 +0.05 83 124 0.13 7 AV4 +0.08 0.10 6 AV5 +0.00 83 132 0.20 9 AV2 +0.02 0.25 11 AV5 +0.02 0.19 9 AV8 +0.05 83 134 0.15 7 AV3 +0.09 0.18 9 AV4 +0.00 0.17 8 AV6 -0.05 83 136 0.15 7 AV5 -0.16 83 138 0.15 8 AV7 -0.05 0.18 9 AV6 -0.05 0.16 8 AV4 -0.02 0.13 7 AV3 +0.00 0.15 7 AV2 -0.05 83 140 0.30 12 AV8 +0.02 0.47 16 AV6 +0.00 0.16 8 AV5 +0.00 0.18 9 AV4 -0.02 0.23 10 AV3 -0.02 0.12 6 AV2 +0.00 83 142 0.45 16 AV7 +0.00 83 146 0.20 9 AV8 -0.19 0.17 8 AV3 +0.02 83 148 0.11 6 AV8 +0.17 83 150 0.25 11 AV1 -0.18 84 35 0.15 8 AV3 +0.00 0.10 6 AV4 +0.18 0.17 8 AV5 +0.02 84 45 0.24 10 AV4 +0.21 84 47 0.12 6 AV4 +0.21 84 51 0.18 8 AV4 +0.03 84 59 0.21 9 AV6 +0.02 84 61 0.36 14 AV6 +0.05 0.21 9 AV8 +0.02 84 63 0.37 14 AV2 +0.00 0.18 8 AV3 +0.05 0.35 13 AV5 -0.03 0.37 14 AV6 +0.00 0.20 9 AV7 +0.02 84 65 0.14 7 AV5 +0.05 84 67 0.15 8 AV8 +0.12 0.12 6 AV7 +0.02 0.39 14 AV3 +0.02 84 69 0.15 7 AV1 +0.18 0.21 9 AV2 +0.05 0.35 13 AV3 +0.05 0.57 18 AV8 +0.02 84 71 0.13 7 AV2 -0.02 84 73 0.34 13 AV2 +0.02 0.30 12 AV8 +0.00 84 75 0.10 6 AV1 +0.00 0.57 18 AV2 +0.02 0.48 17 AV6 +0.02 84 79 0.27 11 AV2 +0.00 0.43 15 AV7 +0.00 84 81 0.19 9 AV3 +0.02 0.38 14 AV7 +0.00 84 83 0.12 6 AV1 +0.02 0.37 14 AV2 +0.02 0.17 8 AV4 +0.00 0.53 18 AV7 +0.02 84 87 0.40 15 AV2 +0.00 84 89 0.14 7 AV1 +0.00 0.47 16 AV2 -0.05 84 91 0.12 6 AV2 -0.02 0.21 9 AV3 +0.00 0.21 9 AV7 +0.00 84 95 0.18 9 AV1 +0.02 0.61 19 AV3 +0.05 0.27 11 AV7 +0.07 84 107 0.44 16 AV5 +0.02 0.19 9 AV2 +0.00 84 109 0.39 15 AV1 +0.00 0.51 17 AV4 +0.00 0.47 16 AV5 +0.05 0.37 14 AV7 +0.02 84 111 0.44 16 AV2 +0.05 0.48 17 AV3 +0.07 0.13 7 AV4 +0.05 0.42 15 AV5 +0.02 0.47 16 AV6 +0.02 84 113 0.53 18 AV6 -0.02 0.30 12 AV2 +0.02 0.20 9 AV1 +0.02 84 115 0.59 19 AV3 +0.02 0.32 13 AV7 +0.02 84 117 0.12 6 AV8 +0.00 0.57 18 AV7 +0.02 0.17 8 AV1 +0.00 0.39 14 AV2 +0.02 0.48 16 AV3 +0.02 84 121 0.10 6 AV4 -0.02 0.17 8 AV6 -0.02 84 123 0.09 5 AV5 +0.17 84 125 0.18 8 AV2 +0.00 84 131 0.32 13 AV2 +0.05 84 133 0.23 10 AV3 +0.02 84 137 0.27 11 AV5 -0.24 84 139 0.16 8 AV8 -0.19 84 141 0.13 7 AV2 -0.02 0.14 7 AV1 -0.05 84 143 0.12 6 AV3 +0.02 84 145 0.17 8 AV7 -0.02 0.15 7 AV3 +0.00 84 147 0.17 8 AV7 -0.05 85 22 0.16 8 AV2 +0.00 0.15 8 AV3 +0.02 0.16 8 AV6 +0.00 85 36 0.16 8 AV4 +0.21 85 40 0.14 7 AV4 +0.13 85 48 0.13 7 AV4 +0.05 85 50 0.12 6 AV4 +0.26 85 56 0.22 10 AV4 +0.18 0.10 6 AV5 +0.05 0.18 9 AV7 +0.00 85 60 0.14 7 AV4 +0.05 0.32 13 AV6 +0.00 0.32 13 AV7 +0.00 85 66 0.15 7 AV3 +0.03 85 68 0.57 18 AV3 +0.00 0.31 12 AV4 +0.06 85 70 0.12 6 AV2 +0.02 85 78 0.08 5 AV8 +0.02 0.24 11 AV2 +0.02 0.54 18 AV3 +0.02 85 80 0.33 13 AV3 +0.05 85 82 0.55 18 AV3 +0.02 85 88 0.21 10 AV2 +0.02 0.16 8 AV3 +0.02 0.13 7 AV6 +0.00 0.42 15 AV7 +0.02 85 90 0.25 11 AV2 +0.05 0.26 11 AV4 +0.05 85 92 0.19 9 AV2 +0.02 0.58 19 AV8 +0.00 85 94 0.17 8 AV1 +0.02 0.31 12 AV2 +0.02 0.26 11 AV8 +0.05 85 100 0.48 16 AV7 +0.00 85 106 0.14 7 AV1 +0.02 0.50 17 AV5 +0.00 0.26 11 AV7 +0.02 85 108 0.15 8 AV1 +0.00 0.18 9 AV7 +0.05 85 112 0.15 7 AV1 +0.05 0.37 14 AV2 +0.05 0.22 10 AV3 +0.05 0.36 14 AV4 +0.05 0.18 8 AV5 +0.05 85 114 0.27 11 AV3 +0.00 0.14 7 AV4 +0.00 0.22 10 AV5 -0.03 0.29 12 AV6 +0.02 85 116 0.14 7 AV1 +0.02 0.23 10 AV3 +0.05 0.37 14 AV4 +0.08 0.46 16 AV5 +0.05 0.38 14 AV6 +0.02 85 118 0.10 6 AV4 +0.18 0.46 16 AV6 +0.00 0.54 18 AV7 +0.05 0.21 9 AV8 +0.02 85 122 0.15 7 AV3 +0.02 85 124 0.16 8 AV4 +0.05 85 128 0.13 7 AV1 +0.02 85 130 0.25 11 AV6 +0.00 85 132 0.17 8 AV3 +0.02 85 134 0.16 8 AV4 +0.00 0.26 11 AV5 +0.02 0.27 11 AV6 +0.00 0.14 7 AV8 +0.12 85 138 0.16 8 AV3 +0.00 0.14 7 AV2 +0.02 85 142 0.09 5 AV8 +0.21 86 23 0.07 4 AV1 -0.17 86 41 0.19 9 AV3 +0.00 86 43 0.20 9 AV4 +0.05 86 45 0.19 9 AV4 +0.21 0.17 8 AV5 -0.13 86 51 0.12 6 AV4 +0.03 86 53 0.17 8 AV2 -0.02 86 55 0.11 6 AV1 +0.00 86 57 0.19 9 AV6 +0.00 86 59 0.13 7 AV3 +0.00 0.17 8 AV4 +0.00 86 63 0.17 8 AV1 +0.02 0.14 7 AV6 +0.00 0.18 8 AV7 +0.02 86 65 0.18 8 AV1 +0.00 0.12 6 AV2 +0.05 0.20 9 AV4 +0.03 0.17 8 AV5 +0.05 0.27 11 AV6 +0.02 86 69 0.25 11 AV3 +0.00 86 75 0.24 10 AV1 +0.05 0.58 19 AV6 +0.05 0.52 17 AV7 +0.05 86 79 0.31 12 AV2 +0.00 0.15 7 AV4 +0.03 0.37 14 AV5 +0.02 0.41 15 AV6 +0.07 86 83 0.36 14 AV2 +0.00 0.45 16 AV3 -0.02 0.52 17 AV7 +0.02 86 87 0.21 9 AV2 +0.00 0.27 11 AV7 +0.02 86 89 0.43 15 AV2 +0.00 86 91 0.37 14 AV3 +0.02 0.47 16 AV7 +0.02 0.16 8 AV8 +0.05 86 97 0.31 12 AV2 +0.00 0.52 17 AV4 +0.05 86 99 0.24 11 AV2 +0.02 0.34 13 AV3 +0.05 0.28 11 AV4 +0.06 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 33 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 18 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.19 9 AV7 +0.05 0.16 8 AV8 +0.07 86 101 0.32 13 AV2 +0.05 86 105 0.10 6 AV6 +0.05 0.46 16 AV4 +0.05 86 107 0.15 8 AV1 +0.00 0.33 13 AV2 +0.02 0.32 13 AV4 +0.08 0.21 10 AV5 +0.05 0.22 10 AV6 +0.02 0.23 10 AV7 +0.07 86 109 0.61 19 AV3 +0.02 0.51 17 AV4 +0.03 86 111 0.23 10 AV3 +0.02 0.13 7 AV4 +0.05 0.13 7 AV6 +0.02 86 113 0.09 5 AV1 +0.00 0.58 18 AV3 +0.02 0.30 12 AV4 +0.03 0.12 6 AV8 +0.07 86 115 0.10 6 AV2 +0.02 0.23 10 AV3 +0.02 0.13 7 AV4 +0.03 0.25 11 AV5 +0.02 86 117 0.20 9 AV3 +0.00 0.42 15 AV4 -0.02 0.23 10 AV5 +0.00 0.11 6 AV6 -0.02 0.22 10 AV7 +0.05 86 121 0.22 10 AV4 +0.08 86 125 0.17 8 AV2 +0.00 86 129 0.12 6 AV5 -0.13 86 135 0.18 9 AV5 -0.03 0.15 7 AV3 +0.00 0.49 17 AV2 +0.00 86 139 0.15 7 AV4 -0.02 86 147 0.22 10 AV7 -0.02 0.12 6 AV3 +0.00 87 26 0.09 5 AV1 +0.19 87 36 0.17 8 AV4 +0.20 87 42 0.16 8 AV4 +0.00 87 44 0.19 9 AV3 +0.02 87 46 0.15 8 AV3 +0.02 0.25 11 AV4 +0.03 87 52 0.17 8 AV3 +0.02 0.15 8 AV4 +0.05 0.20 9 AV7 +0.02 87 54 0.11 6 AV3 +0.05 0.08 5 AV4 +0.08 0.10 6 AV5 +0.05 87 60 0.14 7 AV4 +0.18 87 62 0.16 8 AV7 +0.00 87 64 0.23 10 AV3 +0.02 0.24 10 AV4 +0.03 0.26 11 AV5 +0.00 87 66 0.22 10 AV4 +0.05 0.18 8 AV6 +0.07 87 68 0.16 8 AV8 +0.00 0.29 12 AV6 +0.05 0.16 8 AV7 +0.02 0.35 14 AV5 +0.05 87 70 0.19 9 AV3 +0.02 0.18 9 AV8 +0.02 87 72 0.15 8 AV1 -0.02 0.16 8 AV2 +0.02 0.29 12 AV3 +0.05 0.28 12 AV8 +0.05 87 74 0.17 8 AV2 +0.02 0.62 19 AV3 +0.02 0.62 19 AV4 +0.00 0.56 18 AV6 +0.05 0.61 19 AV7 +0.00 87 76 0.12 6 AV1 +0.05 0.15 7 AV2 +0.02 0.17 8 AV3 -0.02 0.52 17 AV5 +0.02 0.17 8 AV6 +0.02 0.53 18 AV7 +0.02 0.12 6 AV8 +0.02 87 78 0.17 8 AV2 +0.00 0.33 13 AV3 -0.02 0.39 14 AV4 +0.00 0.31 12 AV5 +0.00 0.28 11 AV7 +0.02 87 80 0.33 13 AV2 +0.05 0.35 14 AV7 +0.00 87 82 0.17 8 AV2 +0.05 87 84 0.25 11 AV2 +0.00 0.58 19 AV3 +0.02 87 86 0.54 18 AV7 +0.00 87 88 0.21 9 AV2 +0.02 0.18 9 AV3 +0.02 0.26 11 AV6 +0.00 0.17 8 AV7 +0.02 87 90 0.21 9 AV2 +0.02 0.27 11 AV8 +0.05 87 100 0.20 9 AV1 +0.02 0.25 11 AV7 +0.02 87 106 0.13 7 AV1 +0.00 0.42 15 AV5 +0.07 0.14 7 AV7 +0.09 87 108 0.19 9 AV1 +0.00 0.57 18 AV2 +0.02 0.41 15 AV5 +0.05 0.11 6 AV6 +0.05 87 110 0.18 9 AV1 +0.02 0.34 13 AV2 +0.00 0.20 9 AV4 +0.03 0.54 18 AV5 +0.02 87 112 0.35 13 AV2 +0.05 0.15 7 AV3 +0.05 0.13 7 AV6 +0.05 0.22 10 AV7 +0.02 87 114 0.13 7 AV1 +0.05 0.18 8 AV2 +0.02 0.15 7 AV4 +0.00 0.18 8 AV5 +0.02 87 116 0.11 6 AV7 +0.13 0.12 6 AV2 +0.02 0.18 9 AV5 -0.13 0.15 8 AV6 -0.02 87 118 0.16 8 AV2 +0.00 87 120 0.14 7 AV3 -0.02 0.11 6 AV4 +0.21 87 122 0.27 11 AV6 +0.02 87 126 0.24 10 AV3 +0.02 87 130 0.28 11 AV5 +0.00 87 132 0.29 12 AV5 +0.02 87 148 0.17 8 AV8 +0.22 0.15 8 AV6 +0.00 0.14 7 AV1 -0.18 88 25 0.12 6 AV1 +0.05 88 33 0.07 4 AV5 -0.21 88 35 0.12 6 AV4 +0.23 88 37 0.14 7 AV6 +0.00 88 39 0.10 6 AV5 -0.03 88 45 0.14 7 AV5 -0.18 88 55 0.17 8 AV4 +0.03 88 61 0.42 15 AV6 +0.02 0.40 15 AV7 +0.02 88 63 0.21 9 AV2 -0.02 0.21 9 AV6 +0.02 0.45 16 AV7 +0.02 88 65 0.16 8 AV2 +0.02 0.29 12 AV3 +0.00 88 67 0.10 6 AV2 +0.02 0.17 8 AV3 +0.00 0.22 10 AV5 +0.00 0.11 6 AV6 +0.05 0.27 11 AV7 +0.07 88 69 0.25 11 AV3 +0.00 0.07 4 AV4 -0.19 0.36 14 AV5 +0.00 88 71 0.17 8 AV1 +0.00 0.42 15 AV2 +0.05 0.48 17 AV3 +0.05 0.17 8 AV8 +0.02 88 73 0.30 12 AV1 +0.00 0.49 17 AV5 +0.00 0.10 6 AV7 -0.02 88 75 0.20 9 AV3 +0.02 0.23 10 AV4 +0.00 0.61 19 AV5 +0.02 88 79 0.07 4 AV2 -0.14 0.09 5 AV3 +0.00 0.17 8 AV4 +0.03 0.42 15 AV7 +0.02 0.12 6 AV8 +0.00 88 81 0.13 7 AV2 +0.07 88 83 0.40 15 AV2 +0.00 0.26 11 AV4 +0.08 0.50 17 AV5 +0.05 0.21 9 AV6 +0.05 0.22 10 AV8 +0.02 88 85 0.18 8 AV3 +0.00 0.58 19 AV4 +0.00 88 87 0.19 9 AV2 +0.02 0.32 13 AV5 +0.07 0.26 11 AV7 +0.05 88 89 0.26 11 AV3 +0.02 88 91 0.10 6 AV1 +0.00 0.44 16 AV2 +0.02 0.09 5 AV8 -0.14 88 93 0.22 10 AV3 +0.02 0.49 17 AV4 +0.03 0.25 11 AV7 +0.02 88 95 0.37 14 AV2 +0.05 0.28 12 AV6 +0.02 0.33 13 AV7 +0.00 88 97 0.17 8 AV2 -0.02 0.21 9 AV3 +0.02 88 99 0.39 14 AV2 +0.05 0.31 12 AV5 +0.09 0.31 12 AV7 +0.02 88 101 0.22 10 AV1 +0.02 0.50 17 AV2 +0.02 88 107 0.20 9 AV2 +0.02 0.45 16 AV4 +0.08 0.21 10 AV5 +0.05 0.25 11 AV6 +0.07 88 109 0.31 12 AV2 +0.03 0.42 15 AV5 +0.02 0.15 7 AV7 +0.02 88 111 0.11 6 AV4 +0.00 0.22 10 AV5 +0.00 88 113 0.22 10 AV1 +0.00 0.18 8 AV3 +0.02 0.13 7 AV4 +0.05 88 115 0.22 10 AV5 -0.16 88 117 0.16 8 AV2 +0.02 0.09 5 AV5 +0.21 0.11 6 AV6 +0.05 0.32 13 AV3 +0.05 0.26 11 AV4 +0.00 88 121 0.27 11 AV3 +0.00 88 123 0.29 12 AV4 +0.08 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 34 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 19 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 88 129 0.27 11 AV2 +0.05 88 137 0.14 7 AV7 +0.00 0.18 9 AV3 +0.00 0.18 9 AV2 +0.02 0.15 8 AV1 -0.05 88 147 0.17 8 AV8 +0.20 0.23 10 AV7 -0.05 0.13 7 AV3 +0.18 89 26 0.08 5 AV2 -0.02 0.14 7 AV6 +0.00 0.17 8 AV7 +0.00 89 40 0.09 5 AV5 +0.00 89 46 0.14 7 AV2 +0.00 0.09 5 AV3 +0.00 89 48 0.13 7 AV4 +0.03 89 50 0.14 7 AV4 +0.10 0.17 8 AV5 -0.15 89 54 0.17 8 AV4 +0.03 89 62 0.14 7 AV3 +0.00 89 66 0.11 6 AV4 +0.03 0.11 6 AV7 +0.00 89 68 0.41 15 AV4 +0.05 0.44 16 AV6 +0.07 0.62 19 AV7 +0.02 89 70 0.11 6 AV4 +0.26 0.08 5 AV5 +0.17 0.16 8 AV6 -0.02 0.12 6 AV3 -0.02 89 72 0.41 15 AV2 +0.02 89 74 0.13 7 AV2 +0.02 89 78 0.12 6 AV6 +0.18 0.23 10 AV7 +0.05 0.09 5 AV2 +0.02 0.24 10 AV3 +0.02 89 80 0.10 6 AV2 +0.00 0.20 9 AV3 +0.00 0.20 9 AV4 +0.00 0.50 17 AV6 +0.05 89 82 0.40 15 AV2 +0.00 0.52 17 AV3 +0.02 0.58 19 AV8 +0.00 89 84 0.37 14 AV3 +0.02 0.20 9 AV4 +0.05 0.19 9 AV2 -0.05 0.16 8 AV8 +0.02 89 92 0.46 16 AV2 +0.00 0.32 13 AV7 +0.05 0.32 13 AV5 +0.02 89 96 0.26 11 AV2 +0.05 0.29 12 AV4 +0.05 0.19 9 AV5 +0.05 0.60 19 AV6 +0.05 89 102 0.41 15 AV1 +0.02 0.30 12 AV5 +0.16 89 106 0.14 7 AV3 -0.02 0.40 15 AV6 +0.05 0.26 11 AV7 +0.09 89 108 0.18 9 AV1 +0.00 0.32 13 AV2 +0.02 0.22 10 AV3 +0.02 0.24 10 AV5 +0.05 0.36 14 AV6 +0.05 0.22 10 AV8 +0.02 89 110 0.24 11 AV6 -0.02 0.41 15 AV7 +0.05 0.14 7 AV8 +0.02 89 112 0.34 13 AV2 +0.02 0.27 11 AV7 +0.02 89 114 0.21 10 AV4 +0.00 0.15 7 AV5 -0.16 89 116 0.13 7 AV2 +0.05 0.16 8 AV4 +0.03 0.15 8 AV5 -0.16 89 118 0.17 8 AV5 +0.02 0.25 11 AV6 +0.00 89 120 0.18 9 AV5 +0.00 89 148 0.12 6 AV1 -0.21 90 37 0.10 5 AV2 +0.05 0.20 9 AV6 +0.00 90 41 0.19 9 AV4 +0.08 90 43 0.15 7 AV2 +0.00 0.13 7 AV5 +0.00 90 51 0.17 8 AV5 +0.02 90 53 0.12 6 AV3 +0.02 0.10 6 AV4 -0.02 90 55 0.13 7 AV4 +0.05 90 57 0.29 12 AV5 +0.05 90 59 0.15 8 AV3 +0.02 90 61 0.16 8 AV4 +0.05 90 63 0.28 12 AV3 +0.00 0.20 9 AV6 +0.00 90 65 0.13 7 AV1 +0.00 0.36 14 AV2 +0.02 0.35 14 AV3 +0.00 90 67 0.27 11 AV6 -0.02 90 75 0.20 9 AV1 +0.00 0.37 14 AV2 +0.02 0.46 16 AV3 +0.05 0.51 17 AV4 +0.03 0.61 19 AV5 +0.02 0.58 19 AV8 +0.05 90 79 0.28 12 AV3 +0.02 0.37 14 AV4 +0.03 0.62 19 AV6 +0.02 90 83 0.18 9 AV2 +0.00 0.47 16 AV4 +0.03 0.63 19 AV6 +0.02 90 85 0.15 8 AV2 -0.02 0.32 13 AV3 +0.03 0.12 6 AV8 +0.00 90 87 0.25 11 AV2 +0.02 90 91 0.30 12 AV2 +0.00 90 99 0.29 12 AV1 +0.02 0.38 14 AV6 +0.02 0.45 16 AV7 +0.00 90 103 0.60 19 AV2 +0.02 90 105 0.59 19 AV8 +0.05 0.47 16 AV3 +0.05 90 107 0.16 8 AV2 +0.07 0.24 10 AV3 +0.05 0.18 8 AV4 +0.10 0.36 14 AV5 +0.05 0.32 13 AV6 +0.02 0.62 19 AV7 +0.07 90 109 0.14 7 AV3 +0.00 0.13 7 AV6 +0.07 0.22 10 AV7 +0.02 90 111 0.16 8 AV4 +0.00 0.12 6 AV6 +0.02 0.24 10 AV7 +0.05 90 113 0.21 10 AV3 +0.02 0.30 12 AV6 -0.07 0.15 7 AV1 +0.00 90 115 0.15 7 AV5 +0.07 0.15 8 AV6 +0.02 0.14 7 AV2 +0.00 90 117 0.13 7 AV4 +0.00 0.20 9 AV6 +0.00 90 121 0.20 9 AV3 +0.07 90 125 0.18 9 AV2 +0.02 0.13 7 AV3 +0.05 90 129 0.15 7 AV2 +0.05 90 131 0.15 8 AV3 +0.02 90 133 0.17 8 AV3 +0.00 90 139 0.14 7 AV8 +0.01 0.13 7 AV2 -0.02 91 56 0.13 7 AV7 -0.02 0.11 6 AV5 +0.07 91 58 0.15 7 AV2 -0.05 91 62 0.19 9 AV5 +0.00 0.38 14 AV6 +0.00 91 64 0.62 19 AV7 -0.05 0.61 19 AV6 -0.02 0.51 17 AV4 +0.03 0.16 8 AV2 -0.02 91 66 0.32 13 AV6 +0.05 0.16 8 AV4 +0.00 91 68 0.13 7 AV4 +0.05 0.18 9 AV3 +0.02 0.25 11 AV2 +0.00 91 70 0.27 11 AV7 -0.02 0.19 9 AV3 -0.02 0.16 8 AV1 +0.00 91 72 0.45 16 AV4 +0.00 0.43 15 AV2 +0.00 91 80 0.13 7 AV8 +0.00 0.50 17 AV3 +0.00 91 82 0.58 18 AV3 -0.02 0.18 9 AV2 +0.02 91 90 0.54 18 AV3 -0.02 0.12 6 AV2 -0.02 91 92 0.59 19 AV2 +0.00 91 96 0.15 8 AV8 +0.00 0.23 10 AV1 +0.00 91 98 0.61 19 AV2 +0.05 91 100 0.52 17 AV2 -0.02 0.15 7 AV1 +0.00 0.38 14 AV5 +0.05 0.44 16 AV4 +0.03 91 106 0.11 6 AV7 +0.02 0.41 15 AV5 +0.00 0.49 17 AV2 -0.02 91 108 0.50 17 AV2 +0.00 0.07 4 AV1 +0.13 91 110 0.56 18 AV3 +0.02 0.25 11 AV2 -0.02 91 112 0.12 6 AV6 +0.21 0.11 6 AV5 +0.00 0.37 14 AV3 +0.05 91 114 0.19 9 AV7 +0.00 0.13 7 AV5 -0.05 0.13 7 AV2 -0.05 91 116 0.17 8 AV7 +0.00 0.36 14 AV3 +0.00 91 118 0.10 6 AV6 -0.05 0.13 7 AV2 +0.00 92 45 0.14 7 AV5 -0.03 92 47 0.14 7 AV4 -0.02 0.14 7 AV2 -0.02 92 49 0.16 8 AV4 +0.00 92 51 0.16 8 AV5 +0.02 0.14 7 AV2 +0.05 92 53 0.13 7 AV4 +0.03 92 55 0.25 11 AV4 +0.00 92 59 0.15 7 AV7 -0.03 0.13 7 AV4 -0.05 0.15 7 AV3 -0.02 92 61 0.09 5 AV5 -0.03 92 65 0.25 11 AV8 +0.02 92 67 0.34 13 AV7 -0.02 0.28 11 AV6 +0.02 0.27 11 AV5 +0.02 0.32 13 AV4 +0.03 92 69 0.15 7 AV7 +0.02 0.22 10 AV5 -0.03 0.14 7 AV3 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 35 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 20 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 92 79 0.42 15 AV8 -0.02 0.19 9 AV4 -0.05 0.26 11 AV2 +0.02 92 85 0.14 7 AV8 -0.02 0.38 14 AV2 -0.07 92 87 0.53 18 AV7 +0.00 0.18 8 AV2 -0.05 92 89 0.44 16 AV3 -0.05 92 99 0.35 13 AV8 +0.00 0.44 16 AV2 -0.02 92 101 0.18 8 AV7 -0.02 92 103 0.17 8 AV2 +0.00 0.35 13 AV8 +0.02 0.19 9 AV7 +0.05 92 105 0.50 17 AV3 -0.02 0.12 6 AV1 -0.02 0.37 14 AV7 +0.05 0.23 10 AV8 +0.05 92 107 0.20 9 AV7 +0.02 0.13 7 AV5 +0.00 0.36 14 AV4 +0.00 92 109 0.43 15 AV7 +0.00 0.22 10 AV4 -0.02 0.16 8 AV3 +0.00 92 111 0.27 11 AV6 -0.03 0.33 13 AV5 +0.00 0.27 11 AV4 +0.03 0.22 10 AV3 +0.00 92 113 0.11 6 AV4 +0.03 0.14 7 AV3 +0.02 92 115 0.25 11 AV5 -0.03 0.17 8 AV3 -0.02 92 117 0.35 14 AV7 +0.00 0.22 10 AV6 -0.05 0.21 9 AV4 -0.02 0.11 6 AV3 +0.00 92 119 0.16 8 AV4 +0.00 92 121 0.11 6 AV3 +0.02 92 123 0.11 6 AV5 +0.05 92 125 0.09 5 AV4 +0.08 92 131 0.15 7 AV3 -0.02 92 135 0.11 6 AV5 -0.03 92 137 0.16 8 AV4 +0.00 93 42 0.13 7 AV2 +0.00 0.10 6 AV5 -0.03 93 44 0.14 7 AV5 -0.03 93 48 0.16 8 AV5 -0.05 93 50 0.15 7 AV5 -0.03 0.13 7 AV2 -0.02 93 52 0.11 6 AV4 -0.02 93 56 0.15 8 AV4 +0.18 93 60 0.13 7 AV3 -0.02 93 62 0.24 10 AV5 -0.03 0.13 7 AV3 -0.02 93 64 0.17 8 AV7 +0.00 0.40 15 AV6 -0.02 93 68 0.50 17 AV8 +0.02 0.59 19 AV7 -0.02 0.36 14 AV6 +0.02 0.33 13 AV5 -0.03 0.34 13 AV4 +0.00 0.24 10 AV3 -0.02 93 70 0.51 17 AV7 -0.02 0.53 18 AV4 -0.05 93 78 0.54 18 AV3 +0.00 93 80 0.22 10 AV8 -0.02 0.19 9 AV7 +0.00 0.17 8 AV6 -0.02 0.24 10 AV5 +0.00 0.54 18 AV4 +0.00 0.19 9 AV3 -0.02 93 82 0.25 11 AV3 -0.05 0.29 12 AV2 -0.02 93 88 0.31 12 AV8 +0.00 0.57 18 AV4 -0.02 0.29 12 AV3 -0.02 0.27 11 AV2 +0.00 0.22 10 AV1 -0.02 93 98 0.17 8 AV4 +0.03 0.23 10 AV3 +0.02 0.31 12 AV2 +0.00 0.24 10 AV5 -0.19 93 100 0.25 11 AV5 +0.00 0.23 10 AV3 +0.05 0.11 6 AV2 +0.00 93 102 0.44 16 AV7 -0.02 0.48 17 AV2 -0.04 0.28 12 AV1 -0.02 93 104 0.30 12 AV1 -0.05 0.37 14 AV2 +0.00 0.24 11 AV8 +0.02 93 106 0.32 13 AV5 +0.00 0.37 14 AV2 -0.02 93 108 0.33 13 AV7 +0.00 0.51 17 AV5 +0.00 0.30 12 AV3 +0.00 0.22 10 AV2 -0.02 93 110 0.42 15 AV6 +0.00 0.16 8 AV3 +0.02 93 112 0.29 12 AV3 -0.02 0.59 19 AV5 -0.03 0.29 12 AV4 +0.00 93 114 0.19 9 AV7 +0.02 0.44 16 AV6 +0.00 0.11 6 AV5 -0.19 0.42 15 AV4 +0.03 93 116 0.10 6 AV7 +0.02 0.19 9 AV5 +0.00 0.25 11 AV4 +0.05 0.09 5 AV3 +0.02 0.10 6 AV2 -0.02 93 118 0.11 6 AV3 +0.02 0.13 7 AV2 -0.05 93 122 0.10 5 AV5 +0.12 93 124 0.13 7 AV3 +0.02 93 126 0.15 8 AV4 +0.03 93 128 0.15 7 AV5 +0.00 0.14 7 AV2 -0.02 93 132 0.17 8 AV3 +0.02 94 37 0.16 8 AV5 -0.03 94 53 0.18 9 AV4 +0.03 0.13 7 AV2 -0.07 94 55 0.38 14 AV7 -0.07 0.36 14 AV6 -0.02 0.20 9 AV4 +0.00 94 57 0.17 8 AV8 +0.00 0.14 7 AV5 -0.03 94 59 0.20 9 AV4 +0.03 94 61 0.54 18 AV7 +0.00 0.57 18 AV6 +0.02 0.28 12 AV5 +0.00 0.24 10 AV4 +0.00 0.24 11 AV3 +0.00 0.15 7 AV2 +0.00 94 63 0.36 14 AV6 +0.00 0.20 9 AV4 -0.02 0.33 13 AV3 -0.02 0.15 8 AV2 -0.05 94 65 0.31 12 AV7 +0.07 0.16 8 AV4 +0.00 94 67 0.38 14 AV8 +0.02 0.54 18 AV5 +0.02 0.18 9 AV4 +0.00 94 69 0.16 8 AV7 +0.02 0.27 11 AV6 +0.00 0.36 14 AV5 +0.00 0.50 17 AV4 +0.00 94 71 0.22 10 AV8 -0.02 0.47 16 AV3 +0.00 0.13 7 AV2 -0.02 94 77 0.46 16 AV8 +0.00 0.50 17 AV3 -0.02 0.22 10 AV2 -0.02 94 79 0.26 11 AV7 -0.05 0.59 19 AV5 -0.03 0.13 7 AV4 -0.02 0.24 10 AV3 +0.00 0.53 17 AV2 +0.00 94 81 0.17 8 AV8 +0.00 0.11 6 AV4 -0.02 0.20 9 AV3 +0.00 94 95 0.54 18 AV8 +0.00 0.29 12 AV5 +0.02 0.50 17 AV2 +0.00 94 97 0.25 11 AV7 +0.00 0.46 16 AV5 +0.02 0.20 9 AV3 +0.00 94 107 0.15 8 AV5 +0.00 0.32 13 AV4 +0.00 0.25 11 AV3 +0.00 94 109 0.17 8 AV7 +0.00 0.27 11 AV4 +0.00 94 111 0.58 19 AV6 -0.05 0.25 11 AV5 -0.03 0.14 7 AV3 +0.02 94 113 0.16 8 AV6 -0.07 0.11 6 AV3 +0.02 94 115 0.10 6 AV5 +0.00 0.17 8 AV4 +0.00 0.14 7 AV3 -0.02 94 117 0.13 7 AV5 -0.21 94 121 0.08 5 AV6 -0.02 0.10 6 AV5 -0.05 94 139 0.17 8 AV8 -0.16 95 48 0.10 6 AV5 -0.03 95 50 0.11 6 AV4 +0.13 95 52 0.18 9 AV5 +0.00 95 54 0.16 8 AV4 +0.03 0.09 5 AV3 -0.02 0.10 6 AV2 -0.02 95 60 0.12 6 AV3 +0.00 95 62 0.19 9 AV3 +0.00 0.13 7 AV2 +0.02 95 64 0.38 14 AV7 -0.02 0.55 18 AV6 +0.00 0.58 18 AV5 +0.00 0.24 10 AV4 -0.02 0.18 8 AV3 +0.00 95 66 0.33 13 AV7 +0.02 0.21 9 AV6 +0.05 0.16 8 AV4 +0.00 95 68 0.31 12 AV4 +0.03 0.40 15 AV3 +0.00 0.23 10 AV2 -0.02 0.51 17 AV6 +0.02 95 70 0.25 11 AV8 +0.05 0.35 13 AV7 +0.02 0.32 13 AV5 +0.05 0.11 6 AV4 -0.02 0.24 10 AV2 +0.02 0.14 7 AV1 -0.02 95 74 0.40 15 AV7 +0.02 0.39 14 AV5 +0.00 0.43 15 AV4 +0.00 0.29 12 AV3 +0.00 0.28 12 AV2 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 36 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 21 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 95 78 0.48 16 AV6 +0.00 0.28 12 AV4 -0.02 0.31 12 AV3 +0.00 0.34 13 AV2 -0.02 95 80 0.40 15 AV3 +0.02 0.11 6 AV2 +0.00 95 82 0.37 14 AV3 -0.02 0.31 12 AV2 +0.00 95 84 0.49 17 AV7 +0.00 0.49 17 AV6 +0.00 95 88 0.29 12 AV3 -0.02 0.22 10 AV2 -0.02 95 96 0.50 17 AV7 -0.02 95 98 0.48 16 AV7 +0.00 0.29 12 AV4 +0.03 0.43 15 AV2 +0.00 95 100 0.29 12 AV8 +0.02 0.62 19 AV4 -0.02 0.19 9 AV3 -0.02 0.12 6 AV2 +0.02 95 104 0.53 17 AV7 +0.02 0.22 10 AV6 +0.02 0.28 11 AV2 +0.00 0.41 15 AV4 +0.00 95 106 0.27 11 AV7 +0.05 0.41 15 AV5 +0.00 0.30 12 AV4 +0.03 0.17 8 AV3 +0.00 95 108 0.14 7 AV6 +0.00 0.19 9 AV5 +0.00 0.33 13 AV4 +0.00 0.26 11 AV3 +0.00 95 110 0.22 10 AV6 +0.02 0.16 8 AV4 +0.03 95 112 0.22 10 AV7 +0.02 0.17 8 AV3 +0.05 0.16 8 AV2 -0.05 95 114 0.14 7 AV4 +0.00 95 116 0.16 8 AV4 +0.03 0.13 7 AV3 -0.05 0.16 8 AV2 +0.02 95 120 0.13 7 AV3 -0.21 95 122 0.10 6 AV5 -0.03 95 128 0.20 9 AV5 +0.02 0.30 12 AV4 +0.00 0.12 6 AV3 +0.00 95 130 0.13 7 AV3 +0.07 0.15 7 AV2 +0.02 96 27 0.09 5 AV6 -0.02 0.14 7 AV4 +0.05 0.16 8 AV2 +0.07 96 49 0.16 8 AV4 -0.02 96 53 0.16 8 AV5 +0.02 0.09 5 AV2 -0.16 96 55 0.11 6 AV5 -0.05 0.18 8 AV4 -0.02 96 59 0.12 6 AV7 -0.02 0.16 8 AV4 -0.05 96 61 0.18 9 AV8 +0.00 0.27 11 AV7 +0.02 96 63 0.18 8 AV7 +0.00 0.15 7 AV4 +0.03 96 65 0.47 16 AV6 -0.02 0.24 10 AV4 +0.03 0.52 17 AV3 +0.02 96 67 0.58 18 AV4 +0.00 96 69 0.33 13 AV6 +0.02 0.29 12 AV3 +0.00 96 71 0.43 15 AV3 -0.02 96 75 0.31 12 AV3 -0.02 0.29 12 AV2 +0.00 96 79 0.59 19 AV2 +0.00 0.21 10 AV1 -0.05 96 81 0.33 13 AV3 +0.00 0.15 8 AV2 +0.00 96 91 0.20 9 AV2 -0.02 96 95 0.18 8 AV7 +0.00 0.44 16 AV4 +0.05 0.27 11 AV3 +0.00 0.47 16 AV2 +0.02 96 97 0.25 11 AV8 +0.00 0.37 14 AV7 +0.02 0.15 8 AV6 +0.00 0.48 17 AV5 +0.05 0.40 15 AV3 +0.02 0.12 6 AV2 +0.00 96 103 0.47 16 AV7 +0.00 0.22 10 AV5 -0.03 0.13 7 AV1 -0.14 96 105 0.54 18 AV3 +0.05 0.13 7 AV2 +0.07 0.23 10 AV8 +0.00 0.20 9 AV4 +0.05 96 107 0.22 10 AV7 +0.05 0.27 11 AV6 +0.00 0.31 13 AV5 +0.00 0.34 13 AV4 +0.00 0.22 10 AV3 -0.02 96 109 0.16 8 AV7 +0.02 0.16 8 AV4 +0.00 96 111 0.23 10 AV7 +0.02 0.31 12 AV6 +0.02 0.27 11 AV5 +0.02 0.14 7 AV3 +0.02 96 113 0.11 6 AV5 +0.00 96 115 0.11 6 AV5 +0.14 96 117 0.15 7 AV4 -0.07 96 119 0.17 8 AV7 +0.02 96 121 0.13 7 AV5 +0.00 96 125 0.13 7 AV6 +0.00 96 127 0.21 9 AV2 +0.00 96 133 0.18 8 AV4 +0.03 96 143 0.11 6 AV8 +0.17 97 46 0.21 9 AV5 -0.03 0.14 7 AV2 -0.02 97 50 0.16 8 AV5 +0.00 0.15 8 AV4 +0.00 97 52 0.17 8 AV4 +0.05 97 56 0.11 6 AV5 +0.07 97 60 0.10 6 AV5 +0.02 0.13 7 AV3 -0.02 97 62 0.17 8 AV6 +0.00 0.17 8 AV5 +0.02 0.13 7 AV3 +0.00 97 64 0.17 8 AV5 -0.05 0.12 6 AV4 -0.05 0.21 9 AV3 +0.00 97 66 0.20 9 AV4 +0.06 0.36 14 AV3 +0.02 97 68 0.53 17 AV3 +0.00 97 70 0.28 12 AV7 +0.00 0.63 19 AV5 +0.02 0.19 9 AV4 -0.02 97 72 0.22 10 AV8 +0.02 0.51 17 AV3 +0.05 0.14 7 AV2 +0.00 97 74 0.23 10 AV8 +0.00 0.32 13 AV4 -0.03 0.13 7 AV1 -0.02 97 78 0.21 9 AV6 +0.02 0.59 19 AV5 +0.00 0.38 14 AV4 +0.00 0.60 19 AV3 +0.00 0.48 16 AV2 -0.02 97 82 0.47 16 AV6 +0.00 0.24 10 AV5 +0.00 0.27 11 AV3 +0.00 0.31 12 AV2 -0.02 97 94 0.13 7 AV8 +0.02 0.29 12 AV7 +0.00 0.39 15 AV6 +0.02 0.50 17 AV5 +0.02 0.17 8 AV4 -0.16 0.33 13 AV3 -0.02 0.15 7 AV1 -0.02 97 96 0.27 11 AV7 +0.00 0.21 9 AV2 -0.02 97 98 0.12 6 AV8 +0.02 0.15 7 AV7 -0.05 0.15 8 AV6 -0.02 97 106 0.19 9 AV7 +0.00 0.21 10 AV6 +0.02 0.57 18 AV4 +0.03 0.42 15 AV3 +0.02 0.23 10 AV2 +0.00 97 108 0.21 10 AV7 +0.05 0.58 19 AV4 +0.00 0.23 10 AV3 -0.02 0.11 6 AV2 +0.14 97 110 0.09 5 AV4 -0.02 97 112 0.22 10 AV5 -0.03 0.13 7 AV4 +0.00 0.13 7 AV2 -0.02 97 114 0.14 7 AV4 +0.00 97 116 0.20 9 AV5 -0.03 0.32 13 AV4 +0.00 0.31 13 AV3 +0.02 0.26 11 AV2 -0.02 97 120 0.18 8 AV6 +0.00 98 45 0.12 6 AV4 -0.02 98 53 0.15 7 AV4 +0.03 0.11 6 AV2 -0.07 98 55 0.14 7 AV5 -0.03 0.16 8 AV4 +0.00 0.16 8 AV6 -0.05 98 57 0.13 7 AV4 +0.03 98 59 0.15 7 AV3 +0.02 98 61 0.12 6 AV4 +0.00 98 63 0.16 8 AV4 -0.05 0.19 9 AV3 -0.02 0.13 7 AV2 -0.02 98 65 0.20 9 AV3 -0.02 98 67 0.32 13 AV7 +0.00 0.36 14 AV6 -0.02 0.45 16 AV5 -0.05 98 69 0.42 15 AV7 +0.00 0.29 12 AV5 -0.03 0.17 8 AV3 +0.00 98 71 0.21 10 AV7 +0.02 0.53 18 AV6 +0.02 0.53 18 AV4 -0.02 0.19 9 AV2 +0.00 98 73 0.36 14 AV2 +0.02 0.14 7 AV1 +0.00 98 77 0.41 15 AV7 +0.00 0.33 13 AV3 -0.02 0.24 10 AV2 +0.00 98 79 0.25 11 AV2 -0.02 0.24 10 AV7 +0.02 98 81 0.44 16 AV4 -0.05 0.39 14 AV2 +0.00 0.13 7 AV1 +0.02 98 93 0.23 10 AV2 +0.00 98 97 0.43 15 AV6 +0.02 0.20 9 AV4 +0.03 0.18 8 AV3 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 37 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 22 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 98 99 0.13 7 AV6 -0.16 0.62 19 AV5 +0.00 0.31 12 AV7 +0.00 0.32 13 AV2 +0.00 98 105 0.17 8 AV8 +0.00 98 107 0.14 7 AV7 +0.05 0.30 12 AV5 +0.00 0.54 18 AV4 +0.03 0.48 17 AV3 +0.00 0.25 11 AV2 +0.00 98 109 0.23 10 AV8 +0.02 0.26 11 AV7 +0.00 0.14 7 AV4 +0.03 0.11 6 AV3 +0.00 98 111 0.26 11 AV6 -0.02 0.15 8 AV3 -0.02 98 113 0.09 5 AV4 +0.03 0.16 8 AV3 +0.00 0.16 8 AV2 -0.02 0.18 8 AV5 +0.00 98 117 0.14 7 AV7 +0.02 0.13 7 AV6 +0.00 98 119 0.15 7 AV3 -0.05 98 121 0.13 7 AV5 +0.00 0.10 6 AV4 +0.00 98 123 0.16 8 AV6 +0.00 0.12 6 AV5 +0.02 98 141 0.23 10 AV6 -0.02 0.15 7 AV1 +0.18 98 143 0.11 6 AV1 +0.18 99 54 0.12 6 AV3 +0.00 0.09 5 AV2 +0.00 99 56 0.12 6 AV4 +0.18 99 62 0.11 6 AV5 -0.03 99 64 0.18 9 AV7 -0.02 0.19 9 AV6 +0.00 0.23 10 AV4 +0.05 0.15 7 AV3 -0.02 0.16 8 AV2 -0.02 99 66 0.17 8 AV5 -0.05 0.23 10 AV4 +0.00 0.17 8 AV2 -0.02 0.19 9 AV7 +0.02 0.26 11 AV6 +0.00 99 68 0.57 18 AV5 -0.03 0.24 10 AV3 -0.02 0.11 6 AV2 -0.05 99 70 0.23 10 AV7 +0.02 0.29 12 AV4 +0.03 0.38 14 AV3 +0.02 99 72 0.34 13 AV7 +0.00 99 76 0.19 9 AV7 +0.02 0.52 17 AV3 +0.02 99 78 0.40 15 AV8 +0.00 0.64 19 AV5 +0.05 99 80 0.27 11 AV6 +0.02 0.17 8 AV5 -0.03 0.27 11 AV3 -0.02 0.11 6 AV2 -0.02 99 82 0.28 12 AV7 -0.02 0.17 8 AV6 -0.02 0.53 18 AV4 -0.05 0.12 6 AV3 +0.00 0.15 8 AV2 +0.00 0.09 5 AV1 -0.02 99 96 0.11 6 AV7 +0.05 0.26 11 AV6 +0.00 0.13 7 AV2 +0.02 99 98 0.18 8 AV6 +0.02 0.27 11 AV5 +0.00 0.53 18 AV4 +0.03 0.47 16 AV3 +0.05 0.61 19 AV2 +0.02 99 104 0.23 10 AV4 +0.05 0.13 7 AV3 +0.16 0.08 5 AV2 +0.02 99 106 0.32 13 AV8 +0.02 0.11 6 AV4 +0.03 0.11 6 AV3 +0.02 99 108 0.32 13 AV5 +0.02 0.28 12 AV4 +0.00 0.16 8 AV3 +0.02 99 110 0.32 13 AV6 +0.05 0.13 7 AV5 +0.07 0.20 9 AV4 +0.05 99 112 0.16 8 AV6 +0.00 0.18 9 AV4 +0.03 0.15 8 AV2 -0.02 99 114 0.29 12 AV8 +0.02 0.31 13 AV4 +0.03 0.08 5 AV3 +0.00 99 116 0.10 6 AV5 +0.00 0.08 5 AV3 -0.02 99 118 0.13 7 AV5 +0.02 0.10 6 AV2 +0.00 99 122 0.12 6 AV5 +0.02 99 126 0.08 5 AV2 +0.00 99 130 0.13 7 AV3 +0.02 100 49 0.12 6 AV5 +0.00 100 63 0.16 8 AV2 -0.02 100 65 0.16 8 AV7 +0.02 0.15 7 AV4 +0.03 0.40 15 AV3 +0.00 100 67 0.16 8 AV4 -0.02 0.35 13 AV3 -0.05 0.14 7 AV1 -0.05 100 69 0.26 11 AV8 +0.00 0.32 13 AV5 +0.02 0.21 10 AV3 +0.02 100 71 0.35 14 AV4 +0.00 0.49 17 AV3 +0.02 0.16 8 AV2 +0.00 100 73 0.25 11 AV4 +0.00 100 75 0.21 10 AV8 +0.02 100 77 0.59 19 AV2 +0.00 100 79 0.45 16 AV7 +0.00 100 81 0.36 14 AV8 -0.02 0.26 11 AV4 -0.02 0.31 12 AV2 +0.00 100 91 0.21 10 AV8 +0.02 0.46 16 AV3 -0.02 0.42 15 AV2 -0.02 100 95 0.52 17 AV4 +0.00 0.12 7 AV3 -0.02 100 97 0.12 6 AV7 +0.02 0.50 17 AV5 +0.02 0.38 14 AV4 +0.00 0.44 16 AV3 +0.02 0.14 7 AV2 +0.00 100 99 0.48 16 AV8 +0.00 0.19 9 AV4 +0.03 0.60 19 AV3 +0.00 0.27 11 AV2 -0.02 100 105 0.45 16 AV3 +0.00 0.22 10 AV8 +0.02 100 107 0.43 15 AV2 +0.00 100 109 0.18 8 AV7 +0.02 0.24 10 AV4 +0.03 0.16 8 AV3 -0.02 100 111 0.16 8 AV7 +0.02 0.31 12 AV6 +0.02 0.22 10 AV4 +0.00 100 115 0.10 6 AV5 -0.03 0.23 10 AV4 -0.02 100 121 0.22 10 AV5 +0.00 0.14 7 AV4 -0.02 0.22 10 AV3 +0.00 0.19 9 AV2 +0.00 0.12 6 AV1 -0.02 100 125 0.14 7 AV2 +0.00 100 129 0.19 9 AV5 +0.00 101 52 0.17 8 AV5 -0.03 0.23 10 AV4 +0.03 0.14 7 AV3 -0.02 101 58 0.13 7 AV4 +0.00 101 60 0.12 6 AV5 +0.02 101 64 0.16 8 AV4 -0.16 101 70 0.37 14 AV5 +0.00 0.40 15 AV4 +0.03 0.22 10 AV2 +0.00 101 74 0.30 12 AV2 +0.00 0.29 12 AV8 +0.00 0.26 11 AV7 +0.02 101 78 0.11 6 AV4 -0.18 0.48 17 AV3 +0.00 0.26 11 AV2 +0.00 101 88 0.30 12 AV1 -0.02 0.37 14 AV8 -0.02 0.58 19 AV7 +0.00 101 94 0.12 6 AV6 -0.19 0.26 11 AV4 -0.02 0.44 16 AV3 -0.02 0.46 16 AV2 -0.02 0.16 8 AV1 +0.00 101 96 0.61 19 AV7 +0.02 0.29 12 AV6 +0.02 0.23 10 AV5 +0.05 0.47 16 AV4 +0.03 101 98 0.33 13 AV7 +0.02 0.24 10 AV6 -0.02 0.58 18 AV5 +0.00 0.39 14 AV4 +0.00 0.41 15 AV3 +0.00 101 100 0.16 8 AV7 +0.00 0.27 11 AV5 +0.00 0.16 8 AV4 +0.03 0.25 11 AV3 +0.00 0.12 6 AV1 +0.00 101 106 0.12 6 AV5 -0.18 0.12 6 AV4 -0.02 101 108 0.33 13 AV5 +0.02 0.24 10 AV4 -0.05 101 110 0.20 9 AV5 +0.02 0.35 13 AV4 +0.03 0.30 12 AV3 +0.00 0.11 6 AV2 -0.02 101 112 0.10 5 AV7 +0.02 101 116 0.17 8 AV4 +0.03 101 120 0.14 7 AV5 +0.00 101 128 0.15 7 AV5 -0.03 102 39 0.14 7 AV6 -0.02 102 43 0.15 7 AV5 -0.03 102 45 0.15 7 AV5 +0.00 102 51 0.19 9 AV6 -0.02 0.13 7 AV5 +0.00 0.14 7 AV4 +0.00 102 55 0.20 9 AV4 +0.03 102 59 0.23 10 AV4 +0.00 0.25 11 AV3 +0.02 0.14 7 AV2 -0.02 102 71 0.48 17 AV3 -0.02 0.23 10 AV2 +0.00 102 73 0.22 10 AV7 +0.02 0.45 16 AV4 -0.02 0.55 18 AV3 +0.02 0.38 14 AV2 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 38 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 23 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 102 77 0.47 16 AV7 -0.02 0.59 19 AV3 -0.05 0.47 16 AV2 -0.05 102 79 0.42 15 AV6 +0.05 0.19 9 AV4 +0.05 102 91 0.40 15 AV3 -0.02 0.24 10 AV2 -0.02 0.10 5 AV1 -0.02 102 95 0.44 16 AV5 +0.00 0.24 10 AV3 +0.00 0.35 14 AV2 +0.02 102 97 0.12 6 AV7 -0.02 0.18 8 AV6 +0.02 0.59 19 AV5 +0.02 0.35 14 AV3 +0.00 102 99 0.09 5 AV8 -0.05 0.23 10 AV7 +0.05 0.38 14 AV3 +0.00 0.25 11 AV2 +0.00 102 105 0.21 9 AV3 +0.02 0.54 18 AV7 +0.02 0.63 19 AV6 +0.03 0.36 14 AV4 +0.03 102 107 0.11 6 AV7 +0.05 0.10 6 AV6 +0.19 0.13 7 AV3 +0.00 102 111 0.21 9 AV6 -0.05 0.07 5 AV5 -0.03 0.13 7 AV4 -0.02 0.13 7 AV3 -0.05 0.10 6 AV2 -0.05 102 113 0.12 6 AV4 -0.02 0.24 10 AV3 +0.07 102 115 0.21 9 AV5 -0.03 0.15 7 AV3 -0.02 102 123 0.25 11 AV6 +0.00 102 125 0.11 6 AV6 -0.02 103 44 0.13 7 AV5 +0.00 103 46 0.30 12 AV5 +0.00 103 48 0.17 8 AV5 +0.05 103 54 0.16 8 AV5 +0.05 103 56 0.15 7 AV5 +0.18 0.24 10 AV4 +0.08 0.46 16 AV3 +0.05 0.41 15 AV2 +0.02 103 60 0.17 8 AV4 -0.02 0.08 5 AV3 -0.02 103 64 0.14 7 AV7 +0.02 0.15 7 AV4 -0.02 103 66 0.16 8 AV6 -0.02 103 70 0.51 17 AV6 -0.02 0.49 17 AV5 +0.02 0.50 17 AV4 +0.03 103 72 0.39 15 AV3 +0.00 0.19 9 AV2 -0.05 103 78 0.18 9 AV7 +0.00 103 80 0.18 9 AV5 +0.02 0.47 16 AV4 +0.03 0.62 19 AV3 +0.02 0.10 6 AV2 +0.00 0.49 17 AV8 +0.02 103 82 0.63 19 AV3 +0.02 0.41 15 AV2 +0.00 103 92 0.34 13 AV8 +0.02 0.63 19 AV2 -0.02 0.17 8 AV1 -0.02 103 96 0.25 11 AV8 +0.02 0.56 18 AV4 +0.00 0.58 18 AV3 +0.02 0.13 7 AV2 +0.00 103 98 0.16 8 AV6 -0.02 0.53 18 AV5 +0.02 0.57 18 AV4 +0.00 0.29 12 AV3 -0.02 0.18 8 AV7 +0.02 103 100 0.16 8 AV7 +0.00 0.31 12 AV2 +0.02 103 104 0.09 5 AV3 -0.02 103 106 0.10 5 AV6 +0.03 0.20 9 AV4 -0.02 0.33 13 AV3 -0.02 0.10 6 AV2 -0.02 103 108 0.10 6 AV5 +0.00 0.18 9 AV4 -0.02 103 110 0.12 6 AV6 +0.05 103 112 0.24 11 AV3 +0.02 0.16 8 AV4 +0.03 0.33 13 AV2 +0.00 103 114 0.17 8 AV3 +0.00 0.37 14 AV6 +0.02 0.11 6 AV5 +0.09 103 116 0.12 6 AV7 +0.02 104 49 0.28 11 AV5 -0.03 104 71 0.14 7 AV6 +0.00 0.41 15 AV4 -0.05 0.16 8 AV3 +0.00 0.27 11 AV2 -0.02 104 73 0.44 16 AV5 -0.03 0.61 19 AV3 +0.00 0.28 12 AV2 -0.05 0.60 19 AV7 -0.02 104 75 0.31 12 AV8 +0.05 0.59 19 AV2 +0.00 104 77 0.54 18 AV7 +0.00 0.51 17 AV5 +0.00 0.45 16 AV3 +0.00 104 79 0.50 17 AV6 +0.02 0.52 17 AV5 +0.00 0.41 15 AV3 +0.00 0.37 14 AV2 -0.02 104 81 0.39 15 AV6 +0.00 0.13 7 AV5 -0.03 0.32 13 AV4 -0.02 0.15 8 AV2 +0.00 104 91 0.34 13 AV1 +0.00 104 95 0.21 10 AV6 +0.02 0.23 10 AV5 +0.05 0.60 19 AV4 +0.05 0.14 7 AV3 +0.00 0.26 11 AV2 +0.00 0.14 7 AV1 +0.00 104 97 0.19 9 AV7 +0.02 0.22 10 AV3 +0.02 104 99 0.18 8 AV8 +0.00 0.25 11 AV7 +0.02 0.30 12 AV6 +0.05 0.32 13 AV5 +0.02 0.21 9 AV3 +0.02 0.26 11 AV2 +0.00 104 105 0.50 17 AV4 +0.03 0.12 6 AV3 -0.05 0.09 5 AV2 -0.05 104 107 0.20 9 AV7 +0.05 0.17 8 AV4 +0.03 0.16 8 AV3 +0.00 0.09 5 AV2 +0.02 104 109 0.11 6 AV4 +0.00 104 111 0.10 6 AV6 +0.00 104 117 0.09 5 AV5 -0.03 0.21 9 AV3 -0.05 105 52 0.26 11 AV5 +0.02 0.46 16 AV4 +0.03 0.48 16 AV3 +0.02 0.52 17 AV2 +0.00 105 60 0.13 7 AV3 -0.02 105 62 0.09 5 AV7 -0.16 105 66 0.17 8 AV3 -0.02 105 70 0.27 11 AV5 +0.05 105 72 0.20 9 AV7 +0.00 0.57 18 AV6 +0.02 0.48 16 AV3 -0.02 0.26 11 AV2 +0.00 105 74 0.27 11 AV2 +0.00 105 76 0.16 8 AV8 +0.00 0.46 16 AV3 -0.02 0.17 8 AV2 +0.00 105 78 0.19 9 AV7 +0.02 0.27 11 AV5 -0.03 0.45 16 AV3 -0.02 0.11 6 AV2 -0.02 105 80 0.34 13 AV8 +0.00 0.28 12 AV4 -0.02 0.20 9 AV3 -0.02 0.11 6 AV2 -0.02 105 82 0.46 16 AV7 +0.00 0.29 12 AV2 -0.02 105 96 0.35 13 AV6 +0.00 0.58 19 AV4 +0.00 0.32 13 AV3 +0.00 105 98 0.55 18 AV7 +0.02 0.57 18 AV4 +0.00 0.56 18 AV3 +0.00 0.11 6 AV2 -0.02 105 100 0.16 8 AV8 +0.05 0.23 10 AV7 +0.00 0.45 16 AV6 +0.07 0.15 8 AV3 -0.02 105 104 0.22 10 AV4 +0.05 0.18 9 AV3 +0.00 0.56 18 AV6 +0.02 0.39 14 AV5 +0.00 105 106 0.23 10 AV5 +0.00 0.11 6 AV3 +0.02 105 108 0.12 6 AV5 +0.02 0.16 8 AV4 +0.03 105 112 0.12 6 AV5 +0.02 0.18 8 AV4 +0.03 0.21 9 AV3 +0.02 0.21 10 AV2 +0.00 0.16 8 AV1 +0.02 105 114 0.16 8 AV5 -0.03 0.24 10 AV4 +0.03 0.14 7 AV3 -0.02 105 122 0.17 8 AV5 +0.02 106 45 0.11 6 AV5 +0.05 106 53 0.13 7 AV6 +0.05 0.23 10 AV5 +0.00 106 57 0.13 7 AV5 +0.05 0.17 8 AV4 +0.00 106 63 0.16 8 AV3 +0.02 106 67 0.16 8 AV6 -0.02 0.16 8 AV5 -0.03 106 69 0.20 9 AV7 +0.02 0.17 8 AV5 +0.02 106 71 0.55 18 AV6 +0.00 0.46 16 AV4 -0.02 0.16 8 AV3 -0.02 0.22 10 AV2 +0.00 106 73 0.46 16 AV3 -0.02 0.18 9 AV2 +0.00 0.18 8 AV1 -0.02 106 75 0.58 19 AV4 +0.00 0.22 10 AV3 -0.02 106 77 0.16 8 AV7 +0.02 0.16 8 AV2 -0.05 106 93 0.23 10 AV3 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 39 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 24 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.26 11 AV2 -0.02 0.20 9 AV8 +0.02 0.32 13 AV7 +0.05 106 95 0.61 19 AV3 -0.02 0.52 17 AV2 +0.00 0.15 7 AV1 +0.00 0.32 13 AV8 +0.05 106 97 0.37 14 AV7 +0.00 0.48 17 AV4 +0.00 0.26 11 AV2 +0.02 0.19 9 AV1 -0.02 106 99 0.14 7 AV3 +0.00 0.15 8 AV1 -0.05 0.54 18 AV7 +0.02 106 101 0.14 7 AV3 -0.05 0.39 14 AV7 +0.00 0.40 15 AV6 +0.02 106 103 0.16 8 AV7 +0.05 0.59 19 AV3 -0.05 0.09 5 AV2 -0.02 106 105 0.19 9 AV4 -0.02 106 107 0.14 7 AV5 -0.03 0.14 7 AV3 -0.02 106 111 0.15 8 AV4 -0.02 106 113 0.30 12 AV4 +0.00 0.10 6 AV3 -0.02 0.12 6 AV2 -0.05 106 115 0.19 9 AV2 -0.05 106 121 0.14 7 AV5 +0.00 106 133 0.13 7 AV5 +0.00 107 34 0.15 7 AV1 +0.11 107 44 0.17 8 AV5 -0.03 107 50 0.11 6 AV5 -0.03 0.27 11 AV4 -0.02 0.24 10 AV3 +0.00 0.21 9 AV2 +0.00 107 66 0.14 7 AV3 +0.00 0.16 8 AV6 -0.05 0.14 7 AV4 +0.00 107 68 0.27 11 AV5 -0.03 0.30 12 AV4 -0.02 0.22 10 AV8 +0.00 0.15 7 AV3 +0.00 107 76 0.26 11 AV8 +0.02 0.22 10 AV5 -0.03 0.29 12 AV4 +0.00 0.19 9 AV2 -0.02 107 78 0.50 17 AV7 -0.02 0.54 18 AV6 +0.00 0.20 9 AV5 -0.05 0.26 11 AV4 -0.02 0.51 17 AV3 -0.05 0.22 10 AV2 -0.02 107 86 0.39 15 AV2 -0.02 107 90 0.51 17 AV3 -0.02 0.30 12 AV2 -0.04 0.55 18 AV8 +0.02 107 96 0.17 8 AV8 +0.05 0.12 6 AV5 +0.02 0.53 18 AV4 +0.03 0.37 14 AV2 +0.00 0.21 9 AV1 +0.00 107 98 0.59 19 AV6 +0.02 0.35 14 AV4 +0.00 0.18 9 AV2 +0.02 107 100 0.17 8 AV7 +0.00 0.24 10 AV6 +0.03 0.27 11 AV3 -0.02 0.14 7 AV2 +0.00 107 102 0.08 5 AV7 +0.00 0.57 18 AV5 +0.02 0.45 16 AV4 +0.00 0.08 5 AV2 -0.20 107 104 0.13 7 AV7 +0.00 0.21 9 AV5 +0.00 0.33 13 AV4 +0.03 0.40 15 AV3 +0.02 107 106 0.11 6 AV7 +0.05 0.11 6 AV3 +0.00 107 108 0.22 10 AV6 -0.02 107 110 0.11 6 AV6 +0.07 107 112 0.13 7 AV7 +0.02 0.06 4 AV5 -0.03 0.14 7 AV3 -0.02 0.18 9 AV2 -0.02 107 114 0.09 5 AV4 +0.16 107 120 0.32 13 AV2 +0.05 0.22 10 AV6 +0.02 108 35 0.21 9 AV8 +0.02 0.25 11 AV5 +0.00 108 37 0.14 7 AV8 +0.05 108 49 0.22 10 AV5 +0.02 108 51 0.11 6 AV5 -0.03 108 53 0.17 8 AV4 -0.02 108 67 0.16 8 AV7 +0.05 0.16 8 AV6 -0.05 108 69 0.47 16 AV7 +0.05 0.16 8 AV4 -0.02 0.17 8 AV3 -0.02 0.35 13 AV2 -0.02 108 71 0.19 9 AV7 +0.05 0.63 19 AV4 +0.00 0.52 17 AV3 +0.02 0.54 18 AV2 +0.00 108 73 0.34 13 AV5 +0.00 0.48 17 AV4 -0.02 0.47 16 AV3 +0.00 0.46 16 AV2 -0.02 0.27 11 AV1 +0.00 108 75 0.43 15 AV4 -0.05 0.12 6 AV3 +0.00 108 77 0.16 8 AV8 +0.02 108 79 0.49 17 AV5 +0.00 0.48 17 AV4 -0.02 0.16 8 AV3 +0.00 0.42 15 AV6 -0.02 108 91 0.27 11 AV1 +0.00 108 93 0.14 7 AV1 -0.02 0.17 8 AV8 +0.02 108 97 0.34 13 AV6 +0.02 0.37 14 AV5 +0.00 0.53 18 AV4 +0.00 0.16 8 AV3 +0.00 108 99 0.34 13 AV7 +0.00 0.33 13 AV1 -0.02 108 101 0.38 14 AV7 +0.00 0.13 7 AV6 +0.07 0.32 13 AV4 +0.03 0.20 9 AV1 -0.02 108 103 0.19 9 AV8 +0.05 0.45 16 AV7 +0.05 0.36 14 AV5 -0.05 0.16 8 AV2 -0.02 108 105 0.27 11 AV7 +0.00 0.54 18 AV5 -0.03 0.35 14 AV4 +0.00 0.09 5 AV3 +0.02 108 107 0.11 6 AV4 +0.05 0.15 8 AV3 -0.02 108 109 0.11 6 AV5 +0.02 0.14 7 AV3 -0.02 108 127 0.17 8 AV4 +0.00 108 131 0.15 7 AV5 -0.03 108 135 0.11 6 AV8 +0.21 109 54 0.18 9 AV4 -0.02 109 56 0.17 8 AV5 +0.05 109 58 0.17 8 AV4 -0.02 109 60 0.10 5 AV5 +0.00 0.13 7 AV3 +0.00 109 64 0.17 8 AV4 +0.00 109 66 0.12 6 AV5 -0.03 109 68 0.34 13 AV8 +0.05 0.50 17 AV4 +0.06 0.21 9 AV1 +0.00 109 70 0.55 18 AV7 +0.02 0.21 10 AV4 +0.03 0.16 8 AV3 -0.02 0.14 7 AV2 +0.00 0.13 7 AV1 -0.05 109 76 0.23 10 AV5 +0.05 0.49 17 AV3 +0.00 0.21 10 AV2 +0.00 109 82 0.18 9 AV8 +0.02 0.29 12 AV1 -0.02 109 88 0.47 16 AV8 +0.02 0.33 13 AV3 -0.05 0.24 10 AV2 +0.00 109 92 0.28 11 AV8 +0.02 0.18 8 AV5 +0.00 0.22 10 AV2 +0.00 109 94 0.15 8 AV7 +0.02 0.07 4 AV4 -0.21 0.30 12 AV3 -0.02 0.53 18 AV2 +0.02 0.10 6 AV1 +0.02 109 96 0.20 9 AV5 -0.03 0.49 17 AV4 -0.02 0.36 14 AV3 -0.02 109 98 0.14 7 AV7 +0.00 0.58 18 AV5 +0.00 0.17 8 AV4 -0.02 0.54 18 AV3 -0.02 0.13 7 AV2 +0.02 109 100 0.42 15 AV8 +0.05 0.11 6 AV3 +0.02 109 104 0.32 13 AV7 +0.02 0.31 12 AV6 +0.03 0.19 9 AV5 -0.03 0.33 13 AV4 +0.00 0.28 12 AV3 -0.02 109 106 0.09 5 AV5 -0.18 0.15 8 AV3 -0.02 109 108 0.18 8 AV5 -0.03 109 112 0.13 7 AV3 +0.00 109 116 0.09 5 AV5 -0.03 0.14 7 AV4 +0.05 110 45 0.23 10 AV5 +0.00 110 47 0.22 10 AV5 +0.00 110 57 0.13 7 AV4 -0.07 110 65 0.19 9 AV6 +0.02 0.20 9 AV4 +0.03 0.16 8 AV2 -0.02 110 67 0.12 6 AV6 +0.02 0.14 7 AV2 -0.02 110 69 0.18 8 AV4 -0.02 0.15 7 AV3 -0.02 0.17 8 AV2 -0.05 110 73 0.17 8 AV8 +0.02 0.17 8 AV1 -0.02 110 75 0.15 7 AV8 +0.02 0.38 14 AV6 +0.02 110 77 0.39 14 AV8 +0.02 0.16 8 AV7 +0.02 0.32 13 AV2 +0.02 110 79 0.43 15 AV2 -0.02 0.31 13 AV8 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 40 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 25 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.35 13 AV3 +0.00 110 81 0.57 18 AV6 +0.00 0.23 10 AV3 +0.00 0.19 9 AV2 -0.02 110 93 0.14 7 AV1 -0.02 0.17 8 AV7 +0.00 110 97 0.17 8 AV6 +0.00 110 99 0.15 8 AV7 -0.02 0.55 18 AV3 -0.02 0.15 7 AV2 +0.00 110 101 0.50 17 AV5 +0.00 110 103 0.44 16 AV2 +0.00 0.12 6 AV1 -0.07 110 105 0.25 11 AV6 +0.00 110 109 0.11 6 AV5 -0.03 0.11 6 AV4 -0.02 0.11 6 AV3 +0.00 110 111 0.11 6 AV6 -0.02 110 113 0.26 11 AV3 +0.00 110 115 0.21 10 AV4 +0.03 110 117 0.12 6 AV6 +0.00 110 119 0.13 7 AV5 +0.07 0.11 6 AV3 -0.02 110 123 0.12 6 AV2 +0.00 111 46 0.14 7 AV5 +0.05 111 56 0.32 13 AV7 -0.02 111 62 0.18 9 AV7 +0.05 0.17 8 AV3 +0.02 111 66 0.18 9 AV3 +0.02 111 70 0.19 9 AV6 +0.05 0.24 10 AV4 -0.02 0.18 8 AV3 +0.00 111 72 0.42 15 AV5 -0.03 0.21 10 AV4 -0.05 0.20 9 AV3 +0.00 111 74 0.43 15 AV7 +0.02 0.61 19 AV4 -0.02 111 76 0.50 17 AV4 -0.02 0.15 8 AV3 -0.05 0.13 7 AV2 -0.05 111 80 0.59 19 AV4 -0.05 111 82 0.57 18 AV6 +0.00 0.44 16 AV3 -0.02 0.13 7 AV2 +0.00 111 86 0.32 13 AV7 +0.02 0.36 14 AV1 -0.05 0.17 8 AV8 +0.00 111 98 0.23 10 AV7 +0.02 0.18 9 AV6 +0.02 0.23 10 AV4 +0.00 0.17 8 AV3 +0.05 0.13 7 AV2 +0.02 0.14 7 AV1 +0.00 111 100 0.28 12 AV5 +0.00 0.20 9 AV4 +0.00 0.18 9 AV3 +0.00 0.12 6 AV2 +0.02 111 104 0.06 4 AV8 -0.26 0.09 5 AV7 +0.05 0.19 9 AV5 +0.02 0.26 11 AV4 +0.03 0.26 11 AV3 +0.02 0.08 5 AV2 +0.05 111 106 0.37 14 AV7 +0.07 0.19 9 AV6 +0.03 0.11 6 AV5 +0.00 0.20 9 AV4 +0.00 0.15 7 AV3 -0.02 0.07 4 AV2 -0.02 111 108 0.14 7 AV6 +0.00 111 110 0.11 6 AV3 +0.02 0.13 7 AV2 +0.00 111 126 0.19 9 AV5 +0.00 112 41 0.17 8 AV6 -0.02 0.10 6 AV5 -0.03 0.12 7 AV3 +0.00 112 43 0.08 5 AV5 +0.02 0.10 6 AV2 -0.02 112 45 0.15 7 AV5 -0.03 112 49 0.16 8 AV5 -0.03 112 51 0.25 11 AV5 -0.03 0.10 6 AV4 -0.02 112 53 0.16 8 AV4 +0.00 112 61 0.14 7 AV5 +0.00 112 67 0.11 6 AV6 -0.14 0.10 6 AV5 -0.14 0.17 8 AV3 -0.02 112 69 0.36 14 AV7 +0.02 0.54 18 AV5 +0.00 0.19 9 AV4 -0.02 0.16 8 AV3 -0.02 112 71 0.14 7 AV4 -0.02 0.13 7 AV3 -0.02 112 73 0.45 16 AV8 +0.02 0.48 17 AV7 -0.02 0.54 18 AV5 +0.00 0.24 10 AV3 -0.02 0.13 7 AV2 -0.02 112 75 0.46 16 AV7 +0.02 0.44 16 AV6 +0.02 0.39 15 AV4 +0.00 0.19 9 AV3 -0.02 0.14 7 AV2 -0.05 112 77 0.56 18 AV4 -0.05 0.09 5 AV3 +0.00 112 79 0.54 18 AV2 +0.00 0.08 5 AV1 +0.14 0.44 16 AV8 +0.05 112 81 0.24 10 AV7 +0.02 0.59 19 AV4 -0.02 0.47 16 AV3 -0.05 0.16 8 AV2 +0.00 112 83 0.30 12 AV8 +0.02 0.32 13 AV2 -0.02 112 87 0.33 13 AV8 +0.02 0.17 8 AV1 -0.02 112 95 0.33 13 AV4 -0.02 0.21 9 AV3 +0.00 0.17 8 AV1 +0.00 112 97 0.25 11 AV5 +0.02 0.61 19 AV4 +0.00 0.43 15 AV2 -0.02 0.12 6 AV1 +0.00 112 99 0.57 18 AV7 +0.02 0.58 19 AV5 +0.07 0.41 15 AV4 +0.05 0.14 7 AV1 -0.02 112 103 0.21 9 AV6 +0.00 0.35 13 AV2 +0.00 112 105 0.20 9 AV5 +0.09 112 107 0.25 11 AV3 +0.00 112 109 0.17 8 AV8 +0.07 0.16 8 AV3 +0.00 0.14 7 AV2 +0.00 112 115 0.14 7 AV5 +0.02 112 121 0.14 7 AV5 +0.00 112 127 0.18 8 AV5 +0.00 113 50 0.12 6 AV5 -0.05 0.14 7 AV4 -0.02 0.08 5 AV2 -0.02 113 54 0.19 9 AV4 -0.02 113 56 0.16 8 AV6 +0.00 0.18 9 AV4 +0.05 0.12 6 AV2 -0.02 113 62 0.16 8 AV3 -0.02 113 70 0.15 7 AV3 -0.02 113 74 0.30 12 AV7 +0.05 0.42 15 AV2 +0.00 113 76 0.24 10 AV4 +0.00 0.23 10 AV2 +0.00 113 78 0.35 13 AV8 +0.05 0.39 14 AV3 +0.00 0.34 13 AV2 -0.02 113 80 0.42 15 AV2 +0.00 0.18 8 AV5 +0.00 0.63 19 AV4 +0.03 113 88 0.62 19 AV3 -0.05 0.22 10 AV2 -0.02 113 90 0.31 12 AV2 -0.04 113 94 0.13 7 AV7 +0.00 0.32 13 AV4 -0.05 0.20 9 AV3 -0.02 0.12 6 AV1 -0.02 113 96 0.22 10 AV3 +0.00 0.16 8 AV2 -0.16 113 98 0.42 15 AV5 -0.03 0.16 8 AV4 -0.05 0.12 6 AV3 -0.02 113 100 0.07 5 AV7 -0.43 0.19 9 AV6 +0.05 0.11 6 AV5 +0.02 0.44 16 AV4 +0.00 0.11 6 AV3 +0.00 0.10 6 AV1 -0.02 113 102 0.22 10 AV4 +0.00 0.20 9 AV7 +0.00 0.38 14 AV5 +0.00 113 108 0.28 12 AV6 +0.05 0.26 11 AV2 +0.02 113 110 0.16 8 AV6 +0.03 113 114 0.11 6 AV6 +0.00 0.14 7 AV4 -0.02 113 120 0.19 9 AV4 +0.03 0.14 7 AV3 -0.02 0.10 5 AV2 -0.05 113 122 0.26 11 AV4 +0.00 113 124 0.20 9 AV4 +0.03 0.13 7 AV3 -0.02 114 41 0.23 10 AV5 -0.03 114 49 0.16 8 AV7 +0.02 0.12 6 AV4 +0.00 114 59 0.38 14 AV5 -0.03 114 65 0.17 8 AV4 -0.05 114 67 0.55 18 AV6 +0.02 114 69 0.14 7 AV7 +0.18 114 71 0.27 11 AV5 -0.03 0.18 8 AV4 -0.02 0.18 8 AV3 -0.02 114 75 0.12 6 AV8 -0.02 0.45 16 AV7 +0.02 0.54 18 AV6 +0.00 0.27 11 AV3 +0.00 114 77 0.21 10 AV7 +0.05 0.40 15 AV6 +0.00 0.44 16 AV5 +0.00 0.51 17 AV4 -0.02 0.32 13 AV2 +0.00 114 79 0.34 13 AV3 -0.02 0.17 8 AV8 +0.02 114 81 0.24 10 AV7 +0.00 0.48 16 AV6 +0.00 0.41 15 AV5 +0.00 0.54 18 AV4 -0.02 0.55 18 AV2 -0.02 114 87 0.55 18 AV7 +0.02 0.53 18 AV6 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 41 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 26 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.63 19 AV2 -0.02 114 91 0.53 18 AV2 +0.00 114 93 0.15 7 AV7 +0.02 0.32 13 AV6 +0.14 0.31 13 AV4 -0.02 0.30 12 AV3 +0.00 0.41 15 AV2 -0.02 114 95 0.11 6 AV2 -0.02 0.22 10 AV7 +0.02 0.14 7 AV5 -0.05 0.37 14 AV3 -0.02 114 97 0.15 8 AV6 -0.02 0.38 14 AV5 -0.03 0.17 8 AV4 -0.05 0.30 12 AV3 -0.02 114 101 0.18 8 AV3 +0.02 0.14 7 AV2 +0.02 114 103 0.13 7 AV8 +0.05 0.50 17 AV7 +0.05 0.44 16 AV6 -0.02 0.26 11 AV5 +0.00 0.14 7 AV4 +0.00 114 105 0.26 11 AV6 +0.03 114 107 0.11 6 AV5 -0.03 0.21 9 AV4 +0.03 0.07 4 AV3 +0.00 114 111 0.09 5 AV6 +0.00 0.16 8 AV3 -0.02 114 119 0.12 6 AV7 +0.02 114 125 0.14 7 AV5 +0.00 0.13 7 AV4 +0.05 0.11 6 AV2 +0.00 115 40 0.22 10 AV6 +0.02 0.15 7 AV5 +0.02 0.16 8 AV2 +0.02 115 42 0.14 7 AV6 -0.05 0.14 7 AV4 -0.02 115 48 0.26 11 AV5 +0.00 115 52 0.18 9 AV6 +0.00 115 56 0.19 9 AV4 +0.00 115 58 0.18 8 AV3 +0.02 0.13 7 AV2 +0.00 115 60 0.13 7 AV5 +0.05 115 66 0.27 11 AV8 +0.07 0.62 19 AV5 +0.14 0.36 14 AV4 +0.10 0.52 17 AV3 +0.07 0.16 8 AV1 +0.02 115 70 0.17 8 AV3 -0.02 0.30 12 AV2 +0.00 0.28 12 AV6 +0.02 0.32 13 AV5 +0.02 0.19 9 AV4 +0.00 115 72 0.47 16 AV8 +0.07 0.23 10 AV3 +0.00 0.16 8 AV2 -0.02 0.12 6 AV1 -0.02 115 74 0.33 13 AV7 +0.02 0.30 12 AV5 +0.00 0.54 18 AV4 +0.00 0.33 13 AV1 +0.00 115 76 0.19 9 AV7 +0.00 115 80 0.14 7 AV3 -0.02 0.11 6 AV2 +0.00 115 82 0.32 13 AV2 +0.00 0.24 10 AV8 +0.05 115 92 0.53 18 AV7 +0.02 0.51 17 AV3 -0.05 0.56 18 AV2 -0.02 115 94 0.20 9 AV6 -0.16 0.15 7 AV3 -0.19 115 96 0.16 8 AV6 +0.00 0.14 7 AV5 -0.03 0.36 14 AV4 +0.00 0.27 11 AV3 +0.00 0.22 10 AV2 -0.02 0.16 8 AV1 -0.02 115 102 0.28 12 AV6 +0.07 0.60 19 AV5 +0.05 0.61 19 AV4 +0.05 0.48 16 AV1 +0.00 115 104 0.08 5 AV1 +0.00 0.13 7 AV8 +0.07 0.25 11 AV7 +0.05 0.40 15 AV6 +0.02 0.19 9 AV4 +0.03 0.14 7 AV3 +0.16 115 126 0.20 9 AV4 +0.05 0.13 7 AV3 +0.02 115 130 0.14 7 AV7 +0.02 0.17 8 AV4 +0.03 116 41 0.13 7 AV6 -0.02 116 47 0.11 6 AV5 -0.03 0.13 7 AV3 +0.00 116 51 0.10 6 AV7 +0.02 116 57 0.19 9 AV5 +0.07 0.19 9 AV4 +0.00 0.23 10 AV3 +0.00 116 59 0.26 11 AV5 -0.03 116 61 0.23 10 AV6 +0.00 0.08 5 AV5 +0.00 0.19 9 AV4 +0.03 0.15 7 AV3 +0.00 0.12 6 AV2 -0.02 116 69 0.20 9 AV6 +0.00 0.22 10 AV4 -0.02 0.14 7 AV3 +0.00 116 73 0.21 9 AV6 +0.14 0.16 8 AV4 -0.02 116 75 0.25 11 AV2 +0.00 0.15 8 AV7 +0.00 0.22 10 AV6 +0.00 0.34 13 AV5 -0.05 0.18 8 AV4 -0.05 0.27 11 AV3 -0.02 116 77 0.45 16 AV7 +0.02 0.57 18 AV6 +0.02 0.50 17 AV5 -0.03 0.09 5 AV4 -0.02 116 81 0.36 14 AV7 +0.02 0.27 11 AV2 +0.00 116 91 0.45 16 AV7 +0.02 0.60 19 AV4 -0.02 0.31 13 AV3 -0.02 0.29 12 AV2 -0.02 116 93 0.16 8 AV4 +0.00 0.33 13 AV2 -0.02 0.16 8 AV1 -0.02 116 95 0.24 10 AV4 +0.00 0.62 19 AV3 -0.05 116 97 0.25 11 AV3 +0.00 0.16 8 AV2 +0.00 116 99 0.16 8 AV6 +0.02 0.17 8 AV3 +0.02 0.18 8 AV2 -0.02 0.11 6 AV1 +0.00 116 103 0.15 7 AV2 -0.02 116 129 0.16 8 AV8 +0.07 0.15 7 AV6 +0.00 0.22 10 AV5 -0.03 0.12 6 AV4 +0.03 117 44 0.15 7 AV6 -0.02 0.25 11 AV5 +0.00 0.14 7 AV2 -0.02 117 46 0.20 9 AV6 +0.02 117 48 0.19 9 AV5 -0.03 0.10 6 AV4 +0.00 117 58 0.22 10 AV5 -0.03 117 62 0.10 6 AV7 +0.00 117 64 0.20 9 AV6 -0.02 117 68 0.18 8 AV8 +0.02 0.44 16 AV4 +0.03 0.35 14 AV3 +0.00 0.39 15 AV2 +0.00 117 70 0.14 7 AV5 -0.06 0.17 8 AV4 -0.02 0.12 6 AV3 -0.05 117 72 0.18 8 AV8 +0.05 117 74 0.19 9 AV7 -0.02 117 76 0.18 8 AV8 +0.02 0.54 18 AV7 +0.00 0.35 13 AV5 -0.03 117 80 0.31 12 AV8 +0.02 0.15 8 AV4 +0.00 0.17 8 AV3 -0.05 0.30 12 AV2 -0.02 117 92 0.14 7 AV1 -0.02 0.48 16 AV7 -0.02 117 94 0.62 19 AV4 +0.05 0.26 11 AV3 +0.02 0.13 7 AV2 -0.02 117 96 0.24 10 AV6 +0.00 117 120 0.08 5 AV7 +0.02 0.12 6 AV6 +0.00 0.20 9 AV4 -0.02 0.18 8 AV3 -0.02 117 124 0.44 16 AV6 +0.05 118 69 0.12 6 AV7 +0.18 118 71 0.17 8 AV4 -0.02 118 73 0.33 13 AV5 -0.03 118 75 0.15 8 AV7 -0.17 118 77 0.60 19 AV7 +0.05 0.38 14 AV4 -0.02 0.23 10 AV3 +0.00 0.39 14 AV2 -0.02 0.18 8 AV1 -0.05 118 79 0.48 17 AV6 +0.00 0.17 8 AV5 -0.05 118 81 0.43 15 AV7 +0.00 0.36 14 AV4 -0.05 0.24 10 AV3 -0.05 0.20 9 AV2 -0.02 118 91 0.29 12 AV8 +0.05 0.12 6 AV7 +0.05 0.61 19 AV4 -0.02 0.55 18 AV2 +0.02 118 93 0.37 14 AV7 +0.02 0.41 15 AV6 +0.00 0.39 15 AV5 -0.05 0.28 12 AV3 -0.05 118 101 0.18 8 AV4 -0.02 118 109 0.19 9 AV6 +0.02 118 127 0.13 7 AV7 +0.02 0.17 8 AV5 +0.05 0.15 8 AV4 +0.05 0.16 8 AV3 +0.02 0.23 10 AV2 -0.02 119 54 0.12 7 AV7 +0.00 0.10 6 AV6 -0.02 119 72 0.23 10 AV6 +0.05 0.61 19 AV5 +0.09 0.29 12 AV3 +0.05 0.26 11 AV2 +0.00 0.15 7 AV1 -0.02 119 74 0.20 9 AV8 +0.02 0.34 13 AV7 +0.05 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 42 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 27 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.26 11 AV4 -0.05 0.19 9 AV3 +0.00 0.28 12 AV2 +0.00 0.25 11 AV1 -0.02 119 76 0.57 18 AV4 +0.00 119 78 0.43 15 AV8 +0.02 0.44 16 AV7 +0.02 0.26 11 AV6 +0.00 0.08 5 AV5 -0.18 0.11 6 AV4 -0.05 0.11 6 AV3 -0.02 119 80 0.40 15 AV5 -0.03 0.17 8 AV4 -0.02 0.20 9 AV2 +0.00 119 88 0.11 6 AV2 +0.16 0.30 12 AV1 -0.02 0.35 13 AV8 +0.02 0.57 18 AV6 +0.02 0.25 11 AV5 +0.00 119 94 0.14 7 AV6 +0.00 0.19 9 AV2 -0.05 119 96 0.42 15 AV6 +0.07 0.30 12 AV4 +0.10 0.29 12 AV3 +0.07 0.35 13 AV2 +0.05 0.23 10 AV1 +0.00 119 100 0.35 13 AV5 +0.02 0.33 13 AV4 +0.03 0.28 12 AV3 +0.02 0.10 6 AV2 +0.00 119 106 0.14 7 AV5 +0.05 0.18 8 AV4 -0.05 119 122 0.11 6 AV7 +0.00 0.21 9 AV6 -0.02 0.15 8 AV4 +0.03 0.14 7 AV3 -0.02 0.11 6 AV2 +0.02 120 71 0.15 7 AV7 -0.02 120 73 0.19 9 AV7 +0.00 0.31 13 AV6 +0.00 120 75 0.19 9 AV7 +0.02 120 77 0.10 6 AV2 +0.00 120 79 0.17 8 AV8 +0.00 0.45 16 AV6 +0.02 0.11 6 AV4 -0.05 0.11 6 AV3 +0.00 120 81 0.17 8 AV4 -0.02 0.18 8 AV3 +0.00 120 91 0.48 17 AV7 +0.02 0.41 15 AV6 +0.02 0.62 19 AV3 -0.05 120 93 0.24 10 AV5 +0.02 0.38 14 AV2 -0.02 120 95 0.29 12 AV7 +0.05 0.13 7 AV2 +0.00 120 97 0.62 19 AV7 +0.02 0.61 19 AV5 -0.03 0.19 9 AV4 -0.07 0.57 18 AV3 -0.02 0.30 12 AV2 -0.05 120 99 0.18 9 AV1 +0.00 120 103 0.30 12 AV6 -0.02 0.47 16 AV4 +0.00 0.14 7 AV3 -0.02 0.51 17 AV2 -0.02 120 105 0.25 11 AV6 +0.02 0.18 8 AV5 +0.05 0.20 9 AV4 +0.05 120 107 0.25 11 AV7 +0.07 0.15 8 AV6 +0.05 0.15 7 AV5 +0.05 0.19 9 AV4 +0.05 120 111 0.23 10 AV4 -0.02 0.15 7 AV3 +0.00 0.15 7 AV5 +0.02 120 123 0.11 6 AV8 +0.00 0.39 15 AV6 +0.02 0.25 11 AV5 +0.00 0.18 8 AV4 +0.10 0.37 14 AV3 +0.02 0.10 6 AV2 -0.02 121 76 0.12 6 AV6 +0.00 121 78 0.33 13 AV7 +0.05 0.21 10 AV4 +0.05 0.20 9 AV3 +0.05 0.16 8 AV2 -0.02 121 80 0.35 14 AV8 +0.02 0.21 9 AV7 +0.00 0.28 11 AV6 +0.00 0.19 9 AV5 -0.05 0.15 7 AV4 +0.00 0.10 6 AV2 -0.05 121 82 0.25 11 AV8 +0.02 0.49 17 AV7 +0.00 0.19 9 AV5 +0.00 0.34 13 AV4 -0.02 0.28 11 AV3 -0.02 0.10 6 AV2 -0.07 121 90 0.16 8 AV7 +0.02 0.39 15 AV2 +0.14 0.25 11 AV1 -0.02 121 92 0.18 9 AV8 +0.07 0.27 11 AV5 +0.00 0.11 6 AV1 +0.00 121 94 0.47 16 AV8 +0.05 0.15 7 AV3 -0.02 121 96 0.10 6 AV2 -0.20 121 102 0.19 9 AV4 -0.02 0.35 14 AV3 -0.05 121 108 0.08 5 AV6 +0.02 0.17 8 AV5 +0.02 0.12 6 AV3 +0.02 121 110 0.18 9 AV5 +0.02 0.10 6 AV4 +0.05 122 61 0.19 9 AV7 +0.02 122 65 0.12 6 AV5 -0.08 0.30 12 AV4 -0.02 0.21 9 AV3 -0.02 0.23 10 AV2 +0.00 122 67 0.25 11 AV7 +0.02 0.19 9 AV6 +0.02 0.19 9 AV4 -0.02 122 73 0.14 7 AV7 -0.16 122 75 0.34 13 AV7 +0.00 0.28 12 AV5 -0.05 122 77 0.29 12 AV7 +0.05 0.16 8 AV6 -0.02 122 79 0.27 11 AV2 +0.00 122 81 0.24 10 AV4 -0.07 0.26 11 AV3 -0.05 0.13 7 AV2 -0.02 122 83 0.27 11 AV1 -0.05 122 87 0.48 17 AV4 -0.05 0.15 7 AV3 -0.02 0.19 9 AV2 -0.05 0.30 12 AV8 +0.05 0.46 16 AV7 +0.02 122 93 0.11 6 AV1 +0.02 122 95 0.16 8 AV2 -0.02 122 101 0.15 7 AV6 +0.02 0.17 8 AV5 -0.05 122 115 0.17 8 AV7 +0.02 0.14 7 AV5 +0.02 123 54 0.14 7 AV6 +0.05 0.23 10 AV4 +0.08 123 62 0.12 6 AV6 +0.00 123 72 0.54 18 AV4 -0.05 0.37 14 AV3 +0.00 123 74 0.39 14 AV7 +0.05 0.27 11 AV6 +0.00 0.18 8 AV5 -0.03 0.19 9 AV4 +0.00 0.16 8 AV3 +0.00 123 76 0.17 8 AV8 +0.07 0.46 16 AV7 +0.07 0.14 7 AV6 +0.07 0.17 8 AV5 +0.05 0.16 8 AV4 +0.05 0.14 7 AV3 +0.00 123 78 0.23 10 AV7 +0.05 0.18 8 AV6 +0.02 0.16 8 AV3 -0.05 123 80 0.21 9 AV6 +0.00 0.39 15 AV5 +0.02 0.14 7 AV4 +0.21 0.20 9 AV3 +0.00 123 88 0.61 19 AV4 -0.05 0.32 13 AV2 +0.00 0.27 11 AV7 +0.02 0.44 16 AV6 -0.02 123 90 0.45 16 AV5 +0.00 0.32 13 AV1 -0.02 123 92 0.22 10 AV7 +0.00 0.48 17 AV5 -0.03 0.30 12 AV4 +0.00 0.56 18 AV3 -0.02 0.47 16 AV2 -0.02 0.21 9 AV1 -0.02 123 94 0.24 10 AV8 +0.07 0.58 18 AV5 +0.02 0.28 12 AV3 -0.02 0.22 10 AV2 +0.00 0.12 6 AV1 -0.02 123 96 0.14 7 AV6 -0.02 123 98 0.10 5 AV6 +0.02 0.11 6 AV2 -0.20 123 100 0.13 7 AV8 +0.05 0.16 8 AV7 +0.00 123 104 0.20 9 AV6 +0.00 0.26 11 AV4 +0.00 0.29 12 AV3 -0.02 123 106 0.13 7 AV7 +0.02 0.25 11 AV6 +0.05 0.22 10 AV5 +0.00 0.12 6 AV4 -0.02 124 55 0.19 9 AV7 +0.02 0.19 9 AV6 +0.02 0.30 12 AV5 +0.05 0.36 14 AV4 +0.05 0.12 6 AV8 +0.00 124 63 0.16 8 AV5 +0.00 0.28 11 AV2 +0.00 124 69 0.46 16 AV8 +0.05 0.50 17 AV4 +0.00 0.31 12 AV1 -0.02 124 71 0.27 11 AV7 +0.02 0.22 10 AV6 +0.00 0.30 12 AV5 +0.00 0.14 7 AV2 +0.00 0.23 10 AV4 -0.02 0.27 11 AV3 -0.02 124 73 0.24 10 AV5 -0.03 0.27 11 AV3 -0.02 124 75 0.39 14 AV7 +0.02 0.29 12 AV6 +0.02 0.20 9 AV5 -0.03 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 43 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 28 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.16 8 AV4 -0.02 124 77 0.13 7 AV5 -0.05 0.13 7 AV4 -0.05 124 87 0.18 8 AV3 -0.02 0.33 13 AV2 +0.00 0.34 13 AV7 +0.05 0.60 19 AV6 +0.00 124 91 0.39 15 AV7 +0.00 0.17 8 AV6 -0.02 124 93 0.31 12 AV6 +0.19 0.54 18 AV5 +0.00 0.16 8 AV4 -0.02 0.14 7 AV3 -0.02 0.09 5 AV2 -0.02 124 95 0.18 9 AV7 +0.05 0.15 7 AV6 +0.05 0.34 13 AV4 +0.00 0.37 14 AV3 +0.00 0.13 7 AV2 +0.02 124 97 0.11 6 AV2 -0.18 124 99 0.23 10 AV6 +0.07 0.33 13 AV3 +0.02 0.26 11 AV2 -0.02 124 105 0.22 10 AV4 +0.05 124 113 0.13 7 AV3 -0.05 0.15 7 AV1 -0.02 125 50 0.30 12 AV8 +0.02 0.21 10 AV7 -0.03 0.15 7 AV6 -0.02 125 66 0.17 8 AV4 +0.13 125 68 0.17 8 AV3 -0.02 0.16 8 AV2 -0.02 0.17 8 AV7 +0.00 0.18 9 AV4 +0.00 125 72 0.25 11 AV7 +0.05 0.14 7 AV5 +0.02 125 74 0.55 18 AV6 +0.02 0.48 16 AV5 +0.05 0.42 15 AV4 +0.03 0.13 7 AV2 -0.02 125 76 0.14 7 AV7 +0.24 0.18 8 AV3 +0.00 125 78 0.16 8 AV7 -0.14 125 80 0.43 15 AV6 +0.10 0.57 18 AV4 +0.08 0.56 18 AV3 +0.02 0.15 7 AV2 +0.00 125 82 0.59 19 AV3 -0.05 0.18 8 AV2 -0.02 125 88 0.34 13 AV3 -0.05 0.43 15 AV2 -0.05 125 90 0.36 14 AV8 +0.05 0.58 19 AV3 -0.05 0.49 17 AV2 -0.05 125 92 0.18 8 AV8 +0.07 0.11 6 AV7 -0.14 0.46 16 AV4 -0.05 0.29 12 AV3 -0.02 0.11 6 AV2 +0.00 125 98 0.26 11 AV4 -0.02 0.19 9 AV3 -0.02 0.09 5 AV2 -0.05 125 100 0.14 7 AV5 +0.00 0.08 5 AV4 -0.02 125 102 0.15 7 AV7 +0.05 0.23 10 AV6 +0.10 0.26 11 AV5 +0.09 0.19 9 AV4 +0.08 0.13 7 AV3 +0.02 0.09 5 AV2 +0.18 125 104 0.31 12 AV6 +0.07 125 106 0.22 10 AV6 +0.00 0.20 9 AV5 -0.03 0.49 17 AV4 -0.02 0.18 8 AV3 -0.02 0.12 6 AV2 -0.02 125 108 0.16 8 AV6 +0.00 0.17 8 AV3 -0.02 125 112 0.18 9 AV7 +0.07 125 120 0.20 9 AV6 +0.02 0.17 8 AV5 +0.00 126 55 0.22 10 AV8 +0.05 0.13 7 AV5 +0.02 0.13 7 AV4 -0.02 126 67 0.44 16 AV6 +0.09 0.28 12 AV5 +0.07 0.31 12 AV4 +0.10 0.17 8 AV3 +0.05 126 69 0.14 7 AV8 +0.07 0.32 13 AV5 +0.02 0.37 14 AV4 +0.05 126 71 0.15 7 AV7 +0.00 0.15 7 AV4 -0.02 126 73 0.15 8 AV7 +0.00 0.15 7 AV2 +0.02 126 75 0.23 10 AV8 +0.07 0.28 11 AV7 +0.05 0.14 7 AV6 +0.02 0.19 9 AV5 +0.02 0.26 11 AV4 +0.00 126 77 0.19 9 AV8 +0.07 0.26 11 AV4 -0.02 0.19 9 AV3 -0.05 126 79 0.45 16 AV7 +0.00 0.13 7 AV6 +0.00 0.35 14 AV5 -0.03 0.18 8 AV4 -0.02 126 93 0.16 8 AV6 +0.16 0.40 15 AV5 +0.00 0.18 8 AV4 -0.02 0.17 8 AV3 -0.02 0.29 12 AV2 -0.02 126 95 0.21 9 AV4 +0.03 0.26 11 AV3 +0.00 0.30 12 AV2 +0.00 0.40 15 AV8 +0.10 0.29 12 AV7 +0.07 0.24 10 AV6 +0.02 0.17 8 AV5 +0.02 126 97 0.25 11 AV5 +0.05 0.40 15 AV4 +0.03 0.23 10 AV2 +0.00 126 99 0.10 5 AV5 -0.03 126 101 0.13 7 AV5 -0.05 0.22 10 AV4 -0.05 0.12 6 AV3 -0.02 126 103 0.11 6 AV7 +0.05 0.49 17 AV5 -0.05 0.31 12 AV4 -0.05 0.49 17 AV3 -0.05 0.39 14 AV2 -0.05 0.21 9 AV1 +0.00 126 105 0.21 9 AV8 +0.07 0.16 8 AV6 +0.05 0.16 8 AV5 +0.00 0.45 16 AV4 -0.05 0.49 17 AV3 -0.05 126 109 0.11 6 AV4 +0.00 127 52 0.21 9 AV4 -0.05 127 68 0.19 9 AV7 +0.00 0.31 12 AV4 +0.08 0.12 6 AV3 +0.00 0.27 11 AV1 +0.00 127 70 0.14 7 AV7 +0.12 0.21 10 AV5 +0.07 0.27 11 AV4 +0.08 0.14 7 AV3 +0.05 127 72 0.16 8 AV7 +0.00 0.13 7 AV6 +0.00 127 74 0.29 12 AV7 +0.00 127 76 0.46 16 AV7 +0.11 0.32 13 AV4 +0.08 127 80 0.12 6 AV6 +0.00 0.14 7 AV5 -0.03 0.15 7 AV4 +0.00 0.09 5 AV3 -0.02 127 88 0.58 19 AV4 -0.07 0.18 9 AV1 -0.05 127 90 0.59 19 AV3 -0.05 0.60 19 AV2 -0.05 0.33 13 AV1 -0.02 127 92 0.21 9 AV1 -0.05 127 94 0.15 7 AV7 +0.05 0.18 8 AV6 -0.19 0.35 13 AV5 -0.03 0.33 13 AV4 -0.02 0.23 10 AV3 -0.02 0.11 6 AV2 -0.02 0.17 8 AV1 -0.02 127 96 0.14 7 AV6 +0.00 0.28 11 AV3 +0.00 0.13 7 AV2 -0.02 0.21 10 AV1 +0.00 127 100 0.49 17 AV4 +0.03 0.19 9 AV2 -0.05 127 102 0.16 8 AV7 +0.05 0.31 12 AV4 +0.05 0.23 10 AV3 +0.00 0.19 9 AV2 +0.02 127 108 0.10 6 AV6 +0.02 0.16 8 AV5 -0.03 0.14 7 AV3 -0.02 0.10 6 AV2 -0.02 127 110 0.15 7 AV5 +0.00 127 118 0.13 7 AV8 +0.00 128 53 0.12 6 AV8 +0.00 128 67 0.13 7 AV1 -0.02 0.32 13 AV7 +0.02 128 69 0.23 10 AV5 +0.00 128 73 0.41 15 AV7 +0.05 0.25 11 AV5 +0.00 128 75 0.12 6 AV7 -0.16 0.14 7 AV6 -0.02 128 77 0.16 8 AV7 +0.02 128 79 0.15 8 AV8 +0.02 0.47 16 AV7 +0.00 0.22 10 AV5 -0.03 128 87 0.54 18 AV8 +0.05 0.52 17 AV7 +0.02 0.58 19 AV6 +0.02 128 95 0.19 9 AV8 +0.09 0.40 15 AV5 -0.03 0.23 10 AV4 -0.05 0.10 6 AV3 +0.00 0.17 8 AV2 +0.14 128 97 0.14 7 AV6 +0.02 0.24 10 AV4 -0.02 128 99 0.50 17 AV8 +0.05 0.31 13 AV5 -0.03 0.48 16 AV3 +0.00 0.51 17 AV2 -0.05 128 101 0.22 10 AV6 +0.02 0.37 14 AV5 -0.03 0.23 10 AV4 -0.05 0.11 6 AV3 -0.05 128 103 0.10 5 AV4 -0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 44 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 29 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.17 8 AV2 +0.00 128 107 0.30 12 AV7 +0.07 0.57 18 AV6 +0.00 0.16 8 AV5 +0.00 0.16 8 AV4 -0.02 0.11 6 AV3 -0.02 0.11 6 AV2 -0.05 128 109 0.17 8 AV5 -0.05 0.14 7 AV4 -0.02 128 117 0.28 12 AV5 +0.02 0.37 14 AV4 +0.00 0.17 8 AV2 -0.02 129 66 0.24 10 AV5 +0.05 0.22 10 AV3 +0.02 129 68 0.17 8 AV8 +0.02 0.17 8 AV7 +0.05 0.18 9 AV6 +0.02 0.19 9 AV2 +0.00 129 70 0.18 8 AV7 +0.05 129 72 0.15 7 AV7 +0.18 129 74 0.31 12 AV7 +0.05 0.62 19 AV5 +0.05 0.41 15 AV4 +0.03 0.21 9 AV2 -0.02 129 78 0.37 14 AV8 +0.09 0.07 5 AV2 -0.16 129 86 0.16 8 AV8 +0.05 0.17 8 AV5 +0.00 129 94 0.15 8 AV7 +0.05 0.14 7 AV5 -0.08 0.21 10 AV3 -0.02 0.25 11 AV2 -0.05 129 96 0.19 9 AV5 -0.03 0.25 11 AV4 -0.02 0.10 6 AV2 +0.16 0.14 7 AV1 +0.00 129 98 0.23 10 AV7 +0.00 0.55 18 AV5 +0.00 0.21 10 AV4 -0.02 0.21 10 AV3 -0.02 0.19 9 AV2 +0.16 129 100 0.23 10 AV6 +0.05 129 102 0.11 6 AV6 +0.05 0.13 7 AV5 +0.02 0.22 10 AV4 -0.02 129 104 0.18 8 AV4 +0.00 0.15 7 AV3 -0.07 0.15 8 AV2 -0.05 0.13 7 AV1 -0.05 0.20 9 AV8 +0.07 0.26 11 AV5 -0.03 129 106 0.11 6 AV7 +0.07 0.10 6 AV6 +0.09 0.40 15 AV5 +0.00 0.19 9 AV4 -0.02 0.12 6 AV3 +0.00 0.11 6 AV2 -0.02 129 108 0.10 5 AV6 +0.00 0.10 6 AV5 -0.03 130 69 0.11 6 AV6 +0.02 0.22 10 AV5 +0.02 130 71 0.21 10 AV3 +0.00 0.42 15 AV6 +0.02 0.16 8 AV5 +0.00 0.21 9 AV4 +0.00 130 73 0.21 9 AV8 +0.05 0.31 12 AV7 +0.02 0.16 8 AV6 -0.18 130 75 0.27 11 AV3 +0.00 0.36 14 AV7 +0.05 0.19 9 AV5 +0.00 0.61 19 AV4 -0.05 130 79 0.51 17 AV8 +0.07 0.25 11 AV4 +0.03 0.32 13 AV3 +0.02 130 93 0.52 17 AV8 +0.10 0.57 18 AV6 +0.09 0.34 13 AV5 +0.07 130 95 0.47 16 AV4 +0.03 0.42 15 AV3 +0.02 0.19 9 AV2 +0.00 0.15 7 AV1 -0.02 0.39 14 AV8 +0.07 0.20 9 AV5 +0.07 130 97 0.16 8 AV1 +0.00 0.32 13 AV4 +0.05 0.62 19 AV5 +0.07 130 101 0.13 7 AV6 +0.10 0.26 11 AV5 +0.00 0.47 16 AV4 +0.03 0.29 12 AV3 +0.00 0.19 9 AV2 -0.05 130 109 0.16 8 AV5 -0.05 130 113 0.20 9 AV8 -0.14 131 68 0.12 6 AV3 +0.00 0.13 7 AV2 -0.02 131 70 0.34 13 AV7 +0.05 0.17 8 AV5 -0.03 131 74 0.55 18 AV8 +0.07 0.13 7 AV3 +0.02 0.25 11 AV2 -0.02 131 76 0.18 9 AV6 +0.05 0.42 15 AV5 +0.05 0.26 11 AV4 +0.00 131 78 0.21 9 AV7 +0.07 0.51 17 AV3 +0.00 131 82 0.33 13 AV5 -0.03 131 88 0.16 8 AV8 +0.05 0.23 10 AV6 +0.05 0.46 16 AV3 -0.05 131 92 0.49 17 AV4 -0.02 131 94 0.46 16 AV8 +0.10 0.20 9 AV5 +0.00 0.41 15 AV2 -0.05 0.18 9 AV1 -0.02 131 96 0.17 8 AV6 +0.05 0.18 9 AV5 -0.03 0.16 8 AV4 -0.02 0.13 7 AV2 +0.14 131 98 0.15 7 AV7 -0.02 0.13 7 AV6 +0.05 0.17 8 AV4 -0.02 0.09 5 AV2 -0.05 131 100 0.17 8 AV6 +0.02 0.12 6 AV5 +0.00 131 102 0.53 17 AV7 +0.02 0.16 8 AV6 +0.02 0.15 7 AV5 +0.02 0.14 7 AV3 -0.02 132 69 0.19 9 AV5 +0.12 0.34 13 AV4 +0.13 132 71 0.21 10 AV5 +0.02 0.14 7 AV3 +0.00 0.44 16 AV8 +0.07 132 73 0.33 13 AV8 +0.07 0.45 16 AV7 +0.04 0.17 8 AV6 -0.18 132 75 0.28 11 AV8 +0.07 0.46 16 AV7 +0.02 0.22 10 AV6 +0.07 132 77 0.14 7 AV8 +0.07 0.08 5 AV7 +0.07 0.40 15 AV6 +0.02 0.15 7 AV5 +0.00 0.14 7 AV3 +0.00 132 79 0.29 12 AV8 +0.07 0.40 15 AV4 -0.07 0.25 11 AV3 -0.05 132 81 0.34 13 AV5 -0.03 132 85 0.27 11 AV6 -0.02 132 87 0.35 14 AV7 +0.07 0.39 15 AV5 +0.02 0.13 7 AV4 +0.00 0.10 5 AV3 +0.00 0.08 5 AV2 -0.02 132 93 0.34 13 AV5 -0.03 0.44 16 AV4 -0.05 0.54 18 AV3 -0.05 0.36 14 AV2 -0.05 132 95 0.12 6 AV2 -0.02 0.25 11 AV7 +0.02 0.09 5 AV5 -0.03 0.14 7 AV4 +0.00 132 97 0.31 12 AV7 +0.05 0.14 7 AV6 +0.05 0.20 9 AV5 -0.05 0.49 17 AV4 -0.07 0.34 13 AV3 -0.02 0.13 7 AV2 -0.04 132 99 0.16 8 AV6 +0.07 0.34 13 AV4 +0.08 0.13 7 AV2 -0.16 132 101 0.24 10 AV4 -0.02 133 68 0.25 11 AV5 -0.08 0.29 12 AV4 -0.05 0.54 18 AV3 -0.05 0.21 10 AV1 -0.07 133 70 0.52 17 AV8 +0.05 0.19 9 AV6 -0.02 133 72 0.63 19 AV6 -0.02 0.48 17 AV5 -0.05 0.51 17 AV4 -0.07 133 74 0.36 14 AV8 +0.07 0.20 9 AV6 -0.18 0.30 12 AV4 -0.02 0.13 7 AV2 -0.05 133 76 0.19 9 AV7 +0.09 0.49 17 AV5 +0.02 0.11 6 AV3 +0.16 0.11 6 AV2 +0.02 0.10 6 AV1 -0.02 133 78 0.28 12 AV8 +0.09 0.15 8 AV7 +0.07 0.18 9 AV6 +0.05 0.38 14 AV5 +0.02 0.10 6 AV4 -0.02 0.13 7 AV3 -0.05 133 86 0.51 17 AV4 -0.02 0.19 9 AV1 -0.05 133 88 0.19 9 AV4 -0.12 0.14 7 AV3 -0.09 0.13 7 AV2 -0.09 0.46 16 AV7 -0.02 0.17 8 AV5 -0.08 0.15 7 AV8 +0.05 133 92 0.42 15 AV8 +0.10 0.44 16 AV6 +0.02 0.29 12 AV5 -0.03 0.15 8 AV1 -0.05 133 94 0.22 10 AV7 +0.05 0.45 16 AV6 +0.02 0.32 13 AV5 +0.02 0.54 18 AV4 +0.00 0.33 13 AV3 -0.02 133 102 0.12 6 AV7 +0.07 134 65 0.18 8 AV8 -0.09 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 45 of 86 L-2022-048

Framatome Inc.

9/15/2021 8:05:46 PM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 30 of 30 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 134 67 0.23 10 AV7 +0.11 0.16 8 AV6 +0.00 0.44 16 AV5 +0.12 0.62 19 AV4 +0.00 0.16 8 AV2 -0.02 134 69 0.22 10 AV8 +0.07 0.24 10 AV7 +0.20 0.28 11 AV6 +0.05 134 71 0.24 10 AV7 +0.02 0.16 8 AV6 +0.00 134 73 0.57 18 AV5 -0.08 0.20 9 AV3 -0.05 0.36 14 AV2 -0.07 134 75 0.16 8 AV7 -0.19 0.39 14 AV6 -0.02 0.23 10 AV5 -0.03 0.14 7 AV4 -0.07 134 77 0.21 9 AV7 +0.05 0.23 10 AV6 +0.02 134 79 0.42 15 AV8 +0.05 0.35 14 AV7 +0.02 134 83 0.21 9 AV8 +0.07 0.47 16 AV4 -0.05 0.17 8 AV3 -0.05 134 85 0.28 12 AV7 +0.05 0.40 15 AV6 +0.05 0.25 11 AV5 +0.02 0.23 10 AV4 -0.05 0.37 14 AV3 -0.07 134 87 0.27 11 AV4 +0.00 0.49 17 AV3 +0.00 0.29 12 AV2 -0.05 134 89 0.45 16 AV6 +0.07 0.18 8 AV5 +0.00 0.14 7 AV8 +0.05 0.46 16 AV7 +0.09 134 93 0.13 7 AV8 +0.07 0.15 7 AV6 +0.19 0.53 18 AV5 +0.02 0.40 15 AV4 +0.03 0.18 8 AV3 +0.00 0.22 10 AV2 -0.11 134 95 0.15 7 AV6 +0.05 0.29 12 AV4 -0.02 134 97 0.14 7 AV6 +0.05 0.35 14 AV5 -0.05 0.34 13 AV2 -0.05 0.35 14 AV1 -0.02 134 103 0.17 8 AV7 +0.05 0.26 11 AV6 +0.00 0.32 13 AV5 +0.07 0.28 11 AV4 -0.05 135 70 0.18 8 AV7 +0.07 0.14 7 AV2 -0.02 135 72 0.23 10 AV7 +0.23 0.16 8 AV6 +0.02 0.16 8 AV5 +0.07 0.15 7 AV4 +0.03 135 74 0.10 6 AV8 +0.28 0.23 10 AV7 +0.23 0.11 6 AV6 -0.18 0.21 9 AV5 +0.07 0.12 6 AV2 +0.00 0.15 7 AV1 -0.05 135 76 0.17 8 AV7 +0.07 135 78 0.49 17 AV7 +0.09 135 80 0.28 12 AV7 +0.02 0.07 4 AV2 -0.18 135 92 0.12 6 AV1 -0.02 135 94 0.36 14 AV8 +0.10 0.21 9 AV6 +0.00 0.19 9 AV4 +0.00 0.15 7 AV3 -0.05 0.16 8 AV2 -0.05 0.21 9 AV1 -0.05 135 96 0.26 11 AV7 +0.05 0.35 14 AV6 +0.02 0.13 7 AV2 -0.02 136 71 0.28 12 AV8 +0.07 0.25 11 AV5 +0.00 136 73 0.42 15 AV7 -0.07 0.13 7 AV6 -0.20 0.21 10 AV5 +0.00 0.41 15 AV4 -0.02 0.12 6 AV3 +0.02 0.21 10 AV2 -0.02 0.17 8 AV8 +0.05 136 75 0.12 6 AV8 -0.11 0.23 10 AV4 -0.02 0.20 9 AV3 -0.05 0.13 7 AV2 -0.07 0.15 8 AV1 -0.07 136 79 0.14 7 AV8 -0.12 0.29 12 AV7 +0.00 136 81 0.08 5 AV2 -0.02 0.37 14 AV8 +0.07 0.46 16 AV7 +0.07 0.23 10 AV5 +0.02 0.13 7 AV3 +0.14 136 85 0.45 16 AV7 +0.07 0.34 13 AV6 +0.02 0.25 11 AV4 -0.05 0.12 6 AV3 -0.05 136 91 0.53 17 AV8 +0.07 0.34 13 AV6 +0.07 0.63 19 AV4 +0.00 0.54 18 AV2 -0.05 0.17 8 AV1 -0.05 136 93 0.14 7 AV8 +0.07 0.42 15 AV2 -0.02 0.30 12 AV1 -0.02 136 95 0.15 7 AV6 +0.00 0.19 9 AV4 -0.05 0.11 6 AV2 -0.20 137 74 0.60 19 AV8 +0.09 0.23 10 AV7 +0.09 0.60 19 AV6 +0.02 0.17 8 AV5 +0.00 137 76 0.22 10 AV7 +0.07 0.26 11 AV6 +0.02 0.25 11 AV5 +0.00 0.21 10 AV4 -0.05 0.27 11 AV3 -0.02 0.16 8 AV2 -0.05 0.14 7 AV1 -0.07 137 78 0.18 8 AV7 -0.16 137 84 0.39 14 AV8 +0.07 137 86 0.29 12 AV8 +0.07 0.29 12 AV7 +0.00 137 92 0.54 18 AV7 +0.02 0.31 12 AV6 +0.00 0.12 6 AV3 -0.23 137 94 0.28 12 AV8 +0.07 0.36 14 AV7 +0.05 0.15 7 AV6 -0.18 0.15 7 AV5 +0.02 137 96 0.28 12 AV6 +0.07 138 73 0.24 10 AV7 +0.21 0.35 14 AV6 +0.21 138 75 0.30 12 AV8 +0.02 0.21 10 AV7 +0.23 0.17 8 AV6 +0.05 0.15 8 AV3 -0.05 138 77 0.36 14 AV7 +0.23 0.31 12 AV5 +0.00 0.15 8 AV4 -0.07 0.12 6 AV3 -0.07 138 79 0.23 10 AV7 +0.25 0.60 19 AV6 -0.02 0.20 9 AV4 -0.02 0.17 8 AV3 -0.02 0.14 7 AV8 -0.02 138 81 0.19 9 AV8 +0.00 138 83 0.24 11 AV8 +0.07 0.17 8 AV7 +0.05 0.34 13 AV5 -0.05 138 85 0.15 7 AV8 +0.20 0.23 10 AV7 +0.05 0.38 14 AV6 +0.02 0.18 8 AV4 -0.05 0.18 9 AV5 -0.03 138 87 0.18 8 AV7 +0.05 138 89 0.26 11 AV8 +0.07 138 93 0.10 6 AV8 +0.07 0.31 13 AV7 +0.07 0.15 7 AV5 +0.05 139 78 0.22 10 AV7 +0.23 0.41 15 AV3 +0.00 0.16 8 AV2 -0.07 0.13 7 AV1 -0.21 139 86 0.26 11 AV8 +0.10 0.40 15 AV7 +0.07 0.14 7 AV6 +0.09 139 92 0.14 7 AV3 -0.02 0.31 12 AV2 -0.23 0.11 6 AV8 +0.10 0.40 15 AV6 +0.09 0.21 10 AV5 +0.07 0.43 15 AV4 +0.03 Total Tubes : 2611 Total Records: 6443 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 46 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 1 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 44 163 0.95 24 AV7 -0.22 46 7 0.64 20 AV6 +0.22 51 162 1.05 25 AV6 +0.23 52 153 0.77 22 AV6 -0.25 52 161 1.02 25 AV6 -0.33 53 162 0.70 21 AV6 +0.19 54 9 0.70 21 AV3 -0.21 0.74 21 AV7 -0.22 55 10 0.89 23 AV6 -0.38 0.67 20 AV7 -0.23 55 16 0.95 24 AV6 -0.03 55 160 0.84 23 AV3 +0.30 56 9 0.81 22 AV6 +0.20 56 11 0.96 24 AV6 -0.27 56 161 1.55 30 AV6 -0.33 57 116 0.70 21 AV6 -0.03 57 158 0.74 21 AV6 -0.27 58 11 0.83 23 AV6 -0.03 1.19 27 AV7 +0.00 59 12 0.69 20 AV6 -0.18 59 16 0.73 21 AV6 +0.00 59 156 0.68 20 AV6 -0.05 59 160 1.16 27 AV6 -0.29 60 11 1.04 25 AV6 -0.26 0.66 20 AV7 -0.21 60 141 0.65 20 AV6 -0.05 60 153 1.23 27 AV6 -0.05 60 157 1.24 28 AV7 +0.00 1.41 29 AV6 -0.05 61 16 0.85 23 AV6 -0.03 61 116 1.08 26 AV6 -0.05 61 156 0.98 25 AV8 -0.16 1.99 34 AV6 -0.05 62 11 1.37 29 AV6 -0.23 0.69 20 AV7 +0.28 62 13 0.78 22 AV6 +0.00 62 15 0.80 22 AV6 -0.03 62 105 0.88 23 AV6 +0.05 62 107 1.09 26 AV6 +0.02 62 153 0.68 20 AV8 +0.00 0.76 21 AV7 +0.00 0.72 21 AV6 -0.03 62 157 0.66 20 AV6 -0.05 63 12 2.22 35 AV3 +0.08 1.22 27 AV6 -0.25 63 38 0.67 20 AV6 +0.02 63 114 0.93 24 AV6 -0.05 63 134 0.83 23 AV6 -0.05 63 144 0.89 23 AV6 -0.03 63 146 1.17 27 AV6 -0.05 64 13 0.90 24 AV6 -0.05 64 17 0.99 25 AV6 -0.05 64 29 1.07 26 AV6 +0.02 64 75 0.71 21 AV6 +0.05 64 155 1.11 26 AV3 +0.03 65 12 0.95 24 AV6 -0.22 65 108 0.87 23 AV6 +0.02 65 110 0.84 23 AV6 +0.00 65 134 1.31 28 AV6 +0.00 65 144 0.81 22 AV6 -0.05 65 152 0.71 21 AV7 -0.05 1.39 29 AV6 -0.20 65 154 1.58 31 AV6 -0.03 0.98 25 AV3 +0.05 65 158 0.67 20 AV6 -0.23 66 13 1.49 30 AV6 -0.02 66 15 1.05 25 AV3 +0.07 2.13 34 AV6 -0.02 66 35 0.98 25 AV6 +0.00 66 61 0.86 23 AV6 +0.00 66 99 1.12 26 AV6 +0.05 66 101 0.67 20 AV6 +0.05 66 103 1.54 30 AV6 +0.04 2.01 34 AV7 +0.05 66 105 0.70 21 AV3 +0.03 1.30 28 AV6 +0.05 66 113 0.67 20 AV3 +0.02 0.77 22 AV6 +0.00 66 121 0.65 20 AV6 -0.05 66 145 0.69 20 AV7 -0.02 66 153 1.71 32 AV8 +0.00 1.53 30 AV7 +0.00 1.02 25 AV6 -0.05 0.96 24 AV3 +0.03 67 20 0.87 23 AV6 -0.02 67 44 0.90 24 AV6 +0.00 67 50 0.67 20 AV6 +0.02 67 52 1.52 30 AV6 +0.02 0.77 22 AV7 -0.02 67 74 1.27 28 AV6 +0.02 0.77 22 AV7 -0.02 67 76 0.64 20 AV3 +0.00 0.82 22 AV6 +0.00 67 102 1.13 26 AV3 +0.03 0.91 24 AV6 +0.02 67 104 1.15 27 AV3 +0.00 1.74 32 AV6 +0.02 67 132 0.75 21 AV6 -0.05 67 146 1.65 31 AV3 +0.03 67 148 1.16 27 AV6 -0.05 1.10 26 AV3 +0.00 67 154 2.29 35 AV6 -0.03 1.90 33 AV3 +0.03 68 17 0.98 25 AV6 -0.02 68 67 0.77 22 AV6 +0.05 68 75 0.71 21 AV2 +0.00 0.93 24 AV3 +0.03 2.40 36 AV6 +0.05 0.91 24 AV7 +0.00 68 89 0.77 22 AV3 +0.00 68 99 0.70 21 AV6 +0.05 68 101 1.23 27 AV6 +0.02 68 111 1.95 33 AV6 +0.00 0.90 24 AV7 +0.00 68 115 0.66 20 AV3 +0.00 1.60 31 AV6 +0.00 1.77 32 AV7 +0.05 68 147 1.18 27 AV6 -0.02 68 149 0.83 23 AV6 -0.05 68 155 1.06 26 AV8 -0.16 2.81 38 AV7 -0.02 1.73 32 AV6 -0.05 1.03 25 AV3 +0.00 68 157 1.00 25 AV7 -0.02 2.32 35 AV6 -0.02 69 74 0.67 20 AV6 +0.02 69 88 0.64 20 AV3 +0.03 1.58 31 AV6 +0.02 69 100 1.20 23 AV4 +0.59 0.97 24 AV6 +0.05 69 102 1.88 32 AV4 +1.22 69 104 0.64 20 AV2 +0.02 2.19 35 AV6 +0.02 0.69 20 AV7 +0.02 0.86 21 AV4 +1.14 69 106 2.21 34 AV4 +1.04 0.84 23 AV6 +0.02 69 108 0.84 23 AV3 +0.03 2.15 34 AV4 +1.02 2.01 34 AV6 +0.02 1.01 25 AV7 +0.00 69 112 0.97 22 AV4 +0.85 69 154 1.42 29 AV6 -0.02 70 97 0.68 20 AV6 +0.02 70 101 0.70 21 AV3 +0.00 2.91 38 AV6 +0.05 0.94 24 AV7 +0.02 70 103 0.83 23 AV7 -0.02 70 105 0.82 22 AV3 +0.04 70 109 1.42 29 AV6 +0.02 1.32 28 AV7 +0.00 70 113 0.69 20 AV6 -0.02 71 76 0.86 23 AV6 +0.02 1.25 28 AV7 +0.02 71 98 0.92 24 AV5 +0.04 71 102 0.94 24 AV3 +0.02 1.20 27 AV4 +0.00 0.64 20 AV6 +0.07 71 104 0.96 24 AV6 +0.02 71 108 0.73 21 AV3 +0.02 0.73 21 AV4 -0.02 71 116 0.65 20 AV5 +0.02 72 15 0.64 20 AV4 +0.51 72 25 0.86 23 AV6 +0.00 72 67 1.10 26 AV5 +0.08 1.20 27 AV6 +0.05 0.83 23 AV2 +0.05 1.11 26 AV3 +0.02 72 71 1.42 29 AV6 +0.00 1.23 27 AV7 +0.02 72 75 1.52 30 AV6 +0.02 1.05 25 AV7 +0.02 72 79 0.68 20 AV4 -0.02 0.73 21 AV5 +0.05 1.98 33 AV6 +0.02 1.25 28 AV7 +0.02 1.34 28 AV8 +0.02 72 89 0.77 22 AV6 +0.00 72 91 0.91 24 AV3 +0.04 0.71 21 AV5 +0.11 0.96 24 AV6 +0.05 72 101 0.81 22 AV5 +0.02 1.68 31 AV6 +0.02 72 103 1.02 25 AV3 +0.02 2.13 34 AV5 +0.09 1.46 30 AV6 +0.07 0.94 24 AV7 +0.05 72 105 0.79 22 AV3 +0.02 72 107 1.63 31 AV6 +0.02 72 109 1.48 30 AV5 +0.06 1.21 27 AV6 +0.02 73 18 1.22 27 AV4 +0.37 0.79 22 AV6 -0.02 0.79 22 AV7 +0.02 73 68 0.67 20 AV5 +0.02 73 72 0.64 20 AV6 +0.02 73 74 2.35 36 AV4 -0.11 1.88 33 AV5 +0.04 2.47 36 AV6 +0.02 1.55 30 AV7 +0.00 73 76 0.82 22 AV3 +0.04 1.15 27 AV4 +0.06 2.05 34 AV5 +0.07 1.39 29 AV6 +0.05 1.42 29 AV7 +0.02 73 88 1.00 25 AV3 +0.02 0.72 21 AV4 -0.02 1.44 29 AV5 +0.02 1.23 27 AV6 +0.00 0.96 24 AV7 +0.00 73 92 0.68 20 AV4 +0.17 73 94 0.89 23 AV5 +0.05 0.84 23 AV6 +0.00 73 96 0.85 23 AV4 +0.03 0.92 24 AV5 +0.05 0.88 23 AV6 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 47 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 2 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 73 98 0.89 23 AV5 +0.02 73 102 2.12 34 AV4 -0.02 3.07 39 AV5 +0.02 1.76 32 AV6 +0.02 0.86 23 AV7 +0.00 73 104 2.64 37 AV5 +0.04 2.57 37 AV6 +0.02 73 106 0.74 21 AV4 +0.04 0.69 20 AV2 +0.02 1.10 26 AV3 +0.02 73 108 0.83 23 AV3 +0.02 0.71 21 AV4 +0.03 73 110 0.81 22 AV6 +0.00 0.76 22 AV7 +0.02 73 116 1.18 27 AV5 +0.00 74 67 1.20 27 AV6 +0.02 1.08 26 AV7 +0.00 74 71 1.46 30 AV4 +0.03 1.12 26 AV5 +0.02 1.39 29 AV8 +0.02 74 73 1.13 26 AV3 +0.02 1.48 30 AV4 +0.03 1.43 29 AV5 +0.02 1.18 27 AV6 +0.00 1.14 26 AV7 -0.05 74 75 0.73 21 AV6 +0.02 74 77 0.73 21 AV5 +0.00 1.05 25 AV6 +0.00 74 81 0.87 23 AV3 +0.02 0.89 23 AV4 -0.04 0.74 21 AV5 +0.00 0.95 24 AV6 +0.02 74 87 0.90 24 AV3 +0.02 0.78 22 AV4 +0.00 1.47 30 AV5 +0.04 1.00 25 AV6 +0.02 74 89 1.70 32 AV3 +0.02 0.87 23 AV4 +0.03 1.19 27 AV5 +0.05 1.91 33 AV6 +0.02 0.78 22 AV7 +0.00 74 91 0.78 22 AV6 +0.05 0.70 21 AV7 +0.00 74 93 1.15 27 AV5 +0.07 0.72 21 AV7 +0.02 74 95 0.68 20 AV5 +0.00 1.43 29 AV6 +0.02 0.94 24 AV7 +0.05 74 97 1.08 26 AV3 +0.02 0.71 21 AV4 +0.06 1.50 30 AV5 +0.07 1.06 26 AV6 +0.02 74 101 0.97 24 AV4 +0.03 1.35 29 AV5 +0.02 1.95 33 AV6 +0.05 74 103 0.89 23 AV3 +0.05 74 111 1.19 27 AV5 +0.07 1.04 25 AV6 +0.05 74 145 0.80 22 AV3 +0.00 1.15 27 AV2 +0.00 75 56 0.74 21 AV4 +0.22 75 66 0.95 24 AV5 +0.02 0.82 22 AV6 +0.02 75 72 0.78 22 AV4 +0.03 1.71 32 AV5 +0.05 1.35 29 AV6 +0.05 75 76 0.83 23 AV4 +0.00 1.13 26 AV5 +0.02 75 80 0.73 21 AV4 +0.00 0.96 24 AV5 +0.02 75 86 1.05 25 AV3 +0.00 0.75 21 AV6 +0.02 0.81 22 AV7 +0.02 75 92 0.81 22 AV6 +0.02 75 94 0.65 20 AV3 +0.00 1.46 30 AV4 +0.03 1.05 25 AV5 +0.05 0.92 24 AV6 +0.00 75 96 1.87 33 AV4 +0.03 1.89 33 AV5 +0.05 2.05 34 AV6 +0.02 75 98 1.01 25 AV4 +0.06 0.84 23 AV5 +0.02 0.75 21 AV7 +0.00 75 100 0.97 24 AV6 +0.02 1.07 26 AV7 +0.00 75 104 0.75 21 AV2 +0.02 1.01 25 AV3 +0.02 3.00 39 AV5 +0.00 2.85 38 AV6 +0.02 75 106 0.89 23 AV4 +0.03 0.95 24 AV5 +0.00 0.77 22 AV6 +0.02 75 108 1.14 26 AV3 +0.02 1.46 30 AV4 +0.03 0.70 21 AV5 +0.02 75 116 1.00 25 AV5 -0.11 76 59 0.80 22 AV4 +0.00 1.37 29 AV5 +0.00 1.58 31 AV6 +0.00 76 65 0.75 21 AV5 +0.02 0.83 23 AV6 +0.02 76 71 0.71 21 AV3 +0.02 1.00 25 AV4 +0.03 76 75 0.85 23 AV3 +0.02 0.90 24 AV4 +0.03 2.93 39 AV5 +0.05 2.73 38 AV6 +0.02 1.11 26 AV7 +0.00 76 81 1.37 29 AV7 -0.02 1.04 25 AV3 +0.02 1.76 32 AV4 +0.00 2.51 37 AV5 +0.02 2.39 36 AV6 +0.00 76 87 1.09 26 AV6 +0.05 1.10 26 AV3 +0.02 0.83 23 AV4 +0.05 1.42 29 AV5 +0.02 76 89 0.81 22 AV3 +0.00 0.72 21 AV5 +0.02 0.73 21 AV6 +0.00 76 91 0.76 21 AV6 +0.05 76 95 0.73 21 AV3 +0.02 76 99 0.83 23 AV2 +0.02 2.70 37 AV5 +0.05 1.46 30 AV6 +0.05 0.84 23 AV7 +0.02 76 103 0.68 20 AV2 +0.02 1.14 26 AV4 +0.06 1.14 26 AV5 +0.05 0.88 23 AV6 +0.02 0.94 24 AV7 -0.02 76 105 1.08 26 AV7 +0.02 1.21 27 AV3 +0.02 2.41 36 AV4 +0.06 2.01 34 AV5 +0.05 0.76 22 AV6 +0.05 76 107 0.77 22 AV5 +0.02 1.51 30 AV6 +0.02 0.78 22 AV3 +0.02 1.45 29 AV4 +0.06 76 109 1.91 33 AV5 +0.02 1.25 28 AV6 +0.02 76 111 1.57 30 AV4 +0.08 2.40 36 AV5 +0.05 2.30 35 AV6 +0.02 1.24 27 AV7 +0.02 76 115 0.77 22 AV4 +0.06 0.66 20 AV5 +0.02 1.21 27 AV6 -0.02 77 18 0.87 23 AV4 +0.22 0.66 20 AV6 -0.05 77 64 0.64 20 AV3 +0.02 77 72 1.61 31 AV5 +0.00 1.36 29 AV6 +0.00 77 74 1.40 29 AV4 +0.00 1.68 31 AV5 +0.05 1.30 28 AV6 +0.00 77 76 0.81 22 AV3 +0.00 2.47 36 AV4 +0.00 2.82 38 AV5 +0.02 1.31 28 AV6 +0.00 77 78 1.09 26 AV4 +0.03 1.01 25 AV5 +0.05 77 80 1.68 31 AV3 +0.02 1.41 29 AV4 +0.00 2.65 37 AV5 +0.00 2.08 34 AV6 +0.00 2.14 34 AV7 +0.02 77 88 0.70 21 AV6 +0.02 0.93 24 AV7 +0.02 77 90 0.75 21 AV3 +0.05 1.07 26 AV4 +0.06 1.62 31 AV5 +0.05 0.72 21 AV6 +0.05 77 92 1.58 31 AV3 +0.02 1.93 33 AV4 +0.06 2.87 38 AV5 +0.02 2.03 34 AV6 +0.02 1.28 28 AV7 +0.00 77 94 0.72 21 AV4 +0.03 1.21 27 AV5 +0.02 1.42 29 AV6 +0.02 77 96 0.98 25 AV6 +0.02 77 100 1.01 25 AV3 +0.02 1.17 27 AV6 +0.02 0.85 23 AV7 +0.02 77 102 1.87 33 AV5 +0.05 2.26 35 AV6 +0.02 1.33 28 AV4 +0.03 77 104 0.72 21 AV3 +0.02 3.07 39 AV5 +0.02 77 106 0.67 20 AV3 +0.00 2.71 38 AV4 +0.03 2.47 36 AV5 +0.02 2.07 34 AV6 +0.02 77 108 0.64 20 AV3 +0.02 1.45 29 AV4 +0.03 1.39 29 AV5 +0.02 1.00 25 AV6 +0.02 77 112 1.06 26 AV4 +0.06 1.14 26 AV5 +0.00 1.70 31 AV6 +0.00 1.32 28 AV7 +0.02 77 114 1.28 28 AV4 +0.05 2.51 37 AV5 +0.00 77 116 1.42 29 AV6 -0.02 0.81 22 AV7 +0.02 0.83 23 AV3 +0.02 1.44 29 AV4 +0.06 78 67 0.77 22 AV6 +0.02 78 69 0.88 23 AV3 +0.00 1.71 32 AV4 +0.00 1.76 32 AV5 +0.02 1.25 28 AV6 +0.02 78 71 0.72 21 AV6 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 48 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 3 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 78 73 0.82 22 AV3 +0.02 1.18 27 AV5 +0.02 1.57 31 AV6 +0.00 0.97 24 AV7 +0.07 78 75 0.77 22 AV3 +0.00 1.57 30 AV5 +0.00 1.54 30 AV6 +0.02 1.92 33 AV7 +0.02 0.67 20 AV8 +0.00 78 77 0.93 24 AV4 +0.00 1.54 30 AV5 +0.02 1.47 30 AV6 +0.00 78 79 0.78 22 AV4 +0.03 0.73 21 AV5 +0.05 1.85 33 AV6 +0.05 78 83 0.70 21 AV5 +0.00 0.65 20 AV6 +0.02 78 87 0.79 22 AV4 +0.03 0.75 21 AV5 +0.05 0.83 23 AV6 +0.02 78 89 2.19 35 AV4 +0.03 2.61 37 AV6 +0.02 0.76 22 AV7 +0.00 1.56 30 AV3 +0.02 78 95 0.87 23 AV5 +0.05 0.67 20 AV6 +0.05 1.12 26 AV3 +0.05 1.06 26 AV4 +0.06 78 97 1.07 26 AV3 +0.02 0.98 25 AV4 +0.08 2.25 35 AV6 +0.02 0.75 21 AV7 +0.05 78 101 1.96 33 AV4 +0.05 2.99 39 AV5 +0.02 2.89 38 AV6 +0.05 78 107 1.46 30 AV6 +0.02 78 111 0.92 24 AV4 +0.05 1.34 28 AV5 +0.02 1.53 30 AV6 +0.02 78 113 1.30 28 AV6 -0.02 78 117 0.73 21 AV5 +0.26 0.83 23 AV6 -0.02 0.72 21 AV7 +0.02 79 62 0.86 23 AV5 +0.02 79 68 0.91 24 AV6 +0.07 0.80 22 AV7 +0.05 79 70 0.64 20 AV5 +0.05 0.95 24 AV6 +0.05 79 72 1.80 32 AV5 +0.02 2.33 36 AV6 +0.02 0.84 23 AV7 +0.00 79 74 0.80 22 AV4 +0.00 2.09 34 AV5 +0.02 1.89 33 AV7 +0.00 79 76 1.09 26 AV4 +0.03 3.02 39 AV5 +0.05 1.68 31 AV6 +0.02 1.43 29 AV7 +0.02 79 78 1.41 29 AV7 +0.00 0.78 22 AV4 +0.03 0.77 22 AV5 -0.03 1.01 25 AV6 +0.00 79 80 0.73 21 AV3 +0.02 0.80 22 AV4 +0.03 1.81 32 AV5 +0.02 1.59 31 AV6 +0.00 0.79 22 AV7 +0.00 79 82 0.86 23 AV4 -0.02 0.86 23 AV5 -0.03 79 86 1.84 32 AV3 +0.02 0.64 20 AV4 +0.03 79 90 0.80 22 AV6 +0.05 79 92 1.69 31 AV3 +0.02 1.35 29 AV4 +0.03 1.43 29 AV5 +0.05 2.06 34 AV6 +0.02 79 94 0.82 22 AV3 +0.02 0.89 23 AV4 +0.03 0.88 23 AV5 +0.02 0.66 20 AV6 +0.02 1.17 27 AV7 +0.00 79 96 0.67 20 AV5 +0.05 1.84 32 AV6 +0.02 79 102 1.61 31 AV3 +0.02 2.74 38 AV4 +0.03 2.61 37 AV5 +0.02 1.64 31 AV6 +0.02 79 104 0.90 24 AV2 +0.02 1.12 26 AV3 +0.02 1.32 28 AV5 +0.02 79 106 0.72 21 AV3 +0.00 2.26 35 AV4 +0.06 2.42 36 AV5 +0.05 1.82 32 AV6 +0.02 79 108 0.87 23 AV3 +0.02 1.68 31 AV4 +0.03 1.37 29 AV6 +0.05 1.44 29 AV7 +0.05 79 110 0.69 20 AV3 +0.05 80 67 0.80 22 AV5 +0.00 0.91 24 AV6 +0.05 80 69 0.77 22 AV3 +0.02 1.48 30 AV4 +0.05 1.97 33 AV5 +0.02 1.94 33 AV6 +0.05 1.40 29 AV7 +0.02 80 73 0.67 20 AV4 +0.00 0.92 24 AV5 +0.02 1.19 27 AV6 +0.05 80 75 0.70 21 AV4 +0.00 1.71 32 AV5 +0.02 1.78 32 AV6 +0.00 2.13 34 AV7 +0.02 80 77 1.25 28 AV3 +0.02 1.60 31 AV4 +0.03 1.01 25 AV5 +0.05 1.44 29 AV6 +0.00 80 83 1.39 29 AV5 +0.02 1.50 30 AV6 +0.02 1.33 28 AV7 +0.04 80 85 0.76 21 AV6 +0.05 80 87 0.70 21 AV3 +0.00 1.45 29 AV4 +0.03 1.11 26 AV5 +0.02 1.16 27 AV6 +0.02 0.75 21 AV7 +0.00 80 89 1.52 30 AV3 +0.00 1.72 32 AV4 +0.03 2.34 36 AV5 +0.02 1.99 34 AV6 +0.02 0.66 20 AV7 +0.02 80 91 0.86 23 AV6 +0.05 80 93 1.62 31 AV4 +0.05 2.46 36 AV5 +0.07 0.82 22 AV6 +0.05 80 95 1.12 26 AV3 +0.00 1.71 32 AV4 +0.03 2.06 34 AV5 +0.02 0.70 21 AV6 +0.02 80 99 1.95 33 AV5 +0.00 1.84 32 AV6 +0.02 1.27 28 AV7 +0.00 80 101 2.74 38 AV4 +0.05 2.92 39 AV6 +0.02 0.80 22 AV2 +0.00 1.21 27 AV3 +0.00 80 105 1.06 26 AV5 +0.05 80 107 1.33 28 AV6 +0.05 80 111 1.41 29 AV4 +0.08 0.82 22 AV5 +0.05 0.77 22 AV6 +0.02 80 115 0.64 20 AV5 +0.02 1.28 28 AV6 +0.00 80 117 0.85 23 AV5 +0.21 0.72 21 AV6 -0.02 0.96 24 AV7 +0.00 81 66 0.70 21 AV5 +0.05 0.70 21 AV6 +0.07 81 70 0.80 22 AV3 +0.00 0.70 21 AV5 +0.02 1.26 28 AV6 +0.05 81 74 0.70 21 AV4 +0.08 1.09 26 AV6 +0.02 81 76 1.96 33 AV4 +0.00 2.02 34 AV5 +0.02 81 78 0.72 21 AV3 +0.02 2.87 38 AV4 +0.03 2.88 38 AV5 +0.05 1.43 29 AV6 +0.07 0.76 22 AV7 +0.02 81 80 0.79 22 AV6 +0.02 0.67 20 AV7 +0.00 81 82 1.00 25 AV3 +0.02 2.18 35 AV4 +0.05 2.01 34 AV5 +0.05 2.15 35 AV6 +0.02 1.62 31 AV7 +0.02 81 88 0.91 24 AV5 +0.02 0.76 21 AV6 +0.02 0.81 22 AV7 +0.02 81 90 0.80 22 AV3 +0.00 0.81 22 AV5 +0.07 81 92 0.93 24 AV3 +0.02 0.81 22 AV5 +0.00 1.03 25 AV6 +0.05 81 94 0.96 24 AV3 +0.02 1.06 26 AV4 +0.03 1.42 29 AV5 +0.05 81 96 1.06 26 AV4 +0.05 0.97 25 AV5 +0.05 2.87 38 AV6 +0.05 81 100 0.65 20 AV7 +0.02 0.92 24 AV3 +0.02 2.66 37 AV4 +0.05 1.77 32 AV5 +0.05 2.15 35 AV6 +0.05 81 102 1.91 33 AV4 +0.03 0.79 22 AV7 +0.00 81 106 0.83 23 AV4 +0.03 81 108 0.93 24 AV3 +0.02 81 110 1.42 29 AV5 +0.02 81 114 0.77 22 AV5 +0.02 82 67 1.27 28 AV2 +0.00 1.37 29 AV3 +0.02 1.23 27 AV4 +0.03 2.15 35 AV5 +0.02 3.12 39 AV6 +0.00 0.88 23 AV7 +0.05 82 69 1.09 26 AV4 +0.03 2.03 34 AV5 +0.02 1.35 29 AV6 +0.00 1.13 26 AV7 +0.00 82 77 0.92 24 AV5 +0.02 2.93 39 AV6 +0.00 2.00 34 AV7 -0.05 82 79 1.64 31 AV3 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 49 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 4 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 1.26 28 AV4 +0.05 2.00 34 AV5 +0.05 2.95 39 AV6 +0.05 0.65 20 AV7 +0.02 82 81 0.93 24 AV5 +0.02 0.75 21 AV6 +0.02 1.15 27 AV7 +0.00 82 83 1.25 28 AV4 +0.03 1.99 34 AV5 +0.02 1.70 31 AV6 +0.02 1.26 28 AV7 +0.02 82 85 3.08 39 AV5 +0.00 1.06 26 AV7 +0.00 1.61 31 AV4 +0.00 82 87 1.03 25 AV4 +0.03 82 89 1.50 30 AV3 +0.00 1.81 32 AV4 +0.03 1.26 28 AV5 +0.05 0.66 20 AV6 +0.02 82 91 1.09 26 AV4 +0.03 1.36 29 AV5 +0.00 1.19 27 AV6 +0.02 82 93 1.63 31 AV4 +0.05 2.16 35 AV5 +0.05 1.88 33 AV7 +0.02 82 95 0.70 21 AV2 +0.00 1.48 30 AV3 +0.02 3.01 39 AV4 +0.03 1.52 30 AV6 +0.02 1.37 29 AV7 +0.02 0.67 20 AV8 +0.02 82 97 1.81 32 AV5 +0.05 1.00 25 AV6 +0.05 82 99 0.76 22 AV2 +0.00 1.88 33 AV4 +0.05 3.11 39 AV6 +0.05 1.46 30 AV7 +0.02 82 107 2.21 35 AV6 +0.02 1.88 33 AV7 +0.02 0.68 20 AV8 +0.05 82 109 0.77 22 AV5 +0.07 0.93 24 AV6 +0.05 82 115 0.68 20 AV5 +0.02 0.70 21 AV6 +0.00 82 117 1.29 28 AV5 +0.05 1.08 26 AV6 +0.00 83 64 1.13 26 AV5 +0.02 2.24 35 AV6 +0.02 0.98 25 AV7 -0.02 83 68 0.83 23 AV5 +0.05 1.58 31 AV6 +0.02 1.06 25 AV7 +0.05 83 72 2.63 37 AV5 +0.02 1.86 33 AV6 +0.02 1.88 33 AV7 -0.02 83 74 1.72 32 AV5 +0.02 2.07 34 AV6 +0.00 0.97 25 AV7 +0.02 83 78 2.61 37 AV4 +0.05 2.05 34 AV5 +0.02 1.32 28 AV6 +0.05 1.13 26 AV7 +0.05 83 80 0.67 20 AV4 +0.00 1.01 25 AV5 +0.02 1.97 33 AV6 +0.00 1.37 29 AV7 +0.00 83 84 0.79 22 AV3 +0.00 0.84 23 AV5 +0.02 0.64 20 AV6 +0.05 83 86 1.09 26 AV5 +0.02 1.30 28 AV6 +0.05 1.05 25 AV7 +0.02 83 88 1.21 27 AV4 +0.03 2.23 35 AV5 +0.05 1.52 30 AV6 +0.05 1.35 29 AV7 +0.00 83 92 2.04 34 AV3 +0.02 1.90 33 AV4 +0.03 2.48 36 AV5 +0.02 2.98 39 AV6 +0.02 1.64 31 AV7 +0.02 83 96 2.76 38 AV3 +0.05 2.27 35 AV4 +0.05 2.38 36 AV5 +0.05 2.00 34 AV6 +0.05 0.67 20 AV7 +0.02 83 100 0.93 24 AV4 +0.06 2.27 35 AV5 +0.05 1.91 33 AV6 +0.05 83 106 0.94 24 AV4 +0.05 1.18 27 AV5 +0.05 1.60 31 AV6 +0.05 83 108 0.81 22 AV3 +0.02 0.96 24 AV4 +0.05 1.38 29 AV5 +0.05 1.85 33 AV6 +0.05 83 110 0.65 20 AV4 +0.08 1.08 26 AV5 +0.07 83 112 0.71 21 AV4 +0.03 83 132 0.77 22 AV7 +0.02 83 140 0.68 20 AV7 -0.02 84 61 0.65 20 AV7 +0.05 84 67 1.14 26 AV4 +0.05 1.16 27 AV5 +0.02 1.01 25 AV6 +0.05 84 69 1.41 29 AV4 +0.09 2.85 38 AV6 +0.05 2.38 36 AV7 +0.02 84 71 1.06 26 AV3 +0.00 1.50 30 AV4 +0.00 1.36 29 AV5 +0.00 84 73 0.95 24 AV3 +0.00 1.59 31 AV4 +0.03 1.46 30 AV5 +0.02 2.81 38 AV6 +0.02 1.26 28 AV7 +0.04 84 75 1.36 29 AV3 +0.02 1.67 31 AV4 +0.00 0.94 24 AV5 +0.02 84 79 1.08 26 AV3 +0.00 0.71 21 AV4 +0.00 2.18 35 AV5 +0.00 2.52 37 AV6 +0.00 84 81 0.67 20 AV4 +0.03 2.63 37 AV5 +0.02 1.06 26 AV6 +0.05 84 83 0.96 24 AV5 +0.02 1.20 27 AV6 +0.02 84 85 0.88 23 AV3 +0.05 1.81 32 AV4 +0.03 2.27 35 AV5 +0.02 2.53 37 AV6 +0.05 1.19 27 AV7 +0.02 84 87 1.81 32 AV3 +0.02 2.54 37 AV6 +0.02 0.86 23 AV7 +0.02 84 89 2.68 37 AV3 -0.05 2.83 38 AV4 +0.00 2.65 37 AV5 -0.03 1.98 33 AV6 +0.00 0.80 22 AV7 +0.02 84 91 1.44 29 AV4 +0.05 1.59 31 AV5 +0.02 0.95 24 AV6 +0.02 84 95 1.06 26 AV2 +0.02 1.32 28 AV4 +0.09 1.74 32 AV5 +0.05 1.04 25 AV6 +0.05 84 107 0.73 21 AV3 +0.02 0.76 22 AV4 +0.03 1.21 27 AV6 +0.02 1.17 27 AV7 +0.02 84 109 0.67 20 AV2 +0.00 1.36 29 AV3 +0.02 84 113 0.92 24 AV5 +0.02 0.66 20 AV3 +0.02 0.70 21 AV4 +0.03 84 115 0.70 21 AV4 +0.03 1.70 31 AV5 +0.02 1.43 29 AV6 +0.00 84 117 1.00 25 AV6 -0.02 0.85 23 AV4 +0.08 1.18 27 AV5 +0.02 85 68 0.91 24 AV2 +0.02 0.90 24 AV5 +0.02 0.87 23 AV6 -0.02 1.05 25 AV7 +0.00 85 70 0.77 22 AV3 +0.03 1.45 29 AV4 +0.00 1.48 30 AV5 +0.02 1.51 30 AV6 +0.05 0.77 22 AV7 +0.02 85 78 2.58 37 AV4 +0.00 1.52 30 AV5 +0.02 1.14 26 AV6 +0.02 0.94 24 AV7 +0.05 85 80 0.79 22 AV7 +0.02 0.64 20 AV4 +0.03 0.83 23 AV5 +0.05 1.54 30 AV6 +0.02 85 82 0.85 23 AV4 +0.05 0.95 24 AV5 +0.05 1.19 27 AV6 +0.05 1.46 30 AV7 +0.02 85 88 0.97 24 AV4 +0.03 1.22 27 AV5 +0.05 85 90 1.05 25 AV3 +0.02 1.35 29 AV5 +0.05 0.81 22 AV6 +0.07 85 92 0.64 20 AV3 +0.02 1.41 29 AV4 +0.00 2.28 35 AV5 +0.00 1.98 33 AV6 +0.02 2.88 38 AV7 +0.00 85 94 0.68 20 AV3 +0.02 1.84 32 AV4 +0.03 3.14 39 AV5 +0.05 1.15 27 AV6 +0.05 0.75 21 AV7 +0.02 85 100 0.71 21 AV2 +0.02 1.91 33 AV3 +0.02 1.87 33 AV4 +0.03 2.40 36 AV5 +0.02 1.19 27 AV6 +0.05 85 106 1.85 33 AV4 +0.00 0.85 23 AV6 +0.00 1.43 29 AV2 +0.02 1.97 33 AV3 +0.02 85 108 0.65 20 AV2 +0.02 1.48 30 AV3 +0.02 0.95 24 AV4 +0.03 0.64 20 AV5 +0.02 1.14 26 AV6 +0.02 85 118 0.76 22 AV5 +0.02 86 69 1.42 29 AV4 +0.03 2.75 38 AV5 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 50 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 5 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 2.73 38 AV6 +0.02 1.06 26 AV7 +0.05 86 71 1.31 28 AV7 +0.02 0.79 22 AV4 +0.03 1.88 33 AV5 +0.02 2.12 34 AV6 +0.02 86 75 1.39 29 AV2 +0.02 1.16 27 AV3 +0.05 2.50 36 AV4 +0.03 1.86 33 AV5 +0.05 86 79 0.90 24 AV3 +0.00 86 83 1.12 26 AV4 +0.00 1.80 32 AV5 +0.00 1.62 31 AV6 +0.00 86 87 1.21 27 AV3 +0.00 2.18 35 AV4 +0.05 1.79 32 AV5 +0.05 0.91 24 AV6 +0.08 86 89 0.95 24 AV3 +0.00 2.12 34 AV4 +0.03 2.10 34 AV5 +0.02 2.44 36 AV6 +0.05 0.78 22 AV7 +0.05 86 91 2.42 36 AV4 +0.06 2.48 36 AV5 +0.05 2.75 38 AV6 +0.05 86 97 1.33 28 AV3 +0.02 2.19 35 AV5 +0.05 1.63 31 AV6 +0.02 0.81 22 AV7 +0.02 86 99 0.85 23 AV5 +0.02 1.21 27 AV6 +0.07 86 101 1.08 26 AV3 +0.02 1.43 29 AV4 +0.05 1.47 30 AV7 +0.02 86 105 0.75 21 AV5 +0.07 0.68 20 AV7 +0.05 0.83 23 AV3 +0.02 87 66 0.70 21 AV5 +0.05 87 70 0.92 24 AV4 +0.03 2.16 35 AV5 +0.05 2.37 36 AV6 +0.09 2.28 35 AV7 +0.02 87 72 2.49 36 AV7 +0.02 0.70 21 AV4 +0.03 3.14 39 AV5 +0.05 0.88 23 AV6 +0.02 87 74 1.26 28 AV5 +0.02 87 80 1.96 33 AV6 +0.02 0.72 21 AV3 +0.05 2.40 36 AV4 +0.05 1.91 33 AV5 +0.07 87 82 1.01 25 AV3 +0.05 1.74 32 AV4 +0.03 1.12 26 AV5 +0.02 1.29 28 AV6 +0.02 1.60 31 AV7 +0.02 87 84 1.25 28 AV4 +0.03 2.48 36 AV5 +0.02 2.21 35 AV6 +0.02 0.68 20 AV7 +0.02 87 86 0.72 21 AV2 +0.00 1.51 30 AV3 +0.00 1.05 25 AV4 +0.03 2.39 36 AV5 +0.02 2.18 35 AV6 +0.00 87 88 1.25 28 AV4 +0.03 1.22 27 AV5 +0.02 87 90 0.76 22 AV3 +0.00 0.88 23 AV4 +0.05 3.06 39 AV6 +0.07 1.01 25 AV7 +0.02 87 100 1.68 31 AV2 +0.02 1.46 30 AV3 +0.02 1.72 32 AV4 +0.05 0.94 24 AV5 +0.02 87 106 0.78 22 AV2 +0.02 0.81 22 AV4 +0.08 1.29 28 AV6 +0.05 87 108 1.22 27 AV3 +0.05 0.78 22 AV4 +0.08 87 114 1.46 30 AV6 +0.02 1.94 33 AV7 +0.05 0.92 24 AV8 +0.02 88 69 1.58 31 AV6 +0.00 0.92 24 AV7 +0.02 88 71 1.29 28 AV4 +0.03 2.47 36 AV5 +0.02 2.53 37 AV6 +0.02 1.40 29 AV7 +0.04 88 73 1.46 30 AV2 +0.05 0.74 21 AV3 +0.02 0.83 23 AV4 +0.03 1.31 28 AV6 +0.00 0.92 24 AV8 +0.05 88 75 1.37 29 AV6 +0.00 1.99 34 AV7 +0.00 1.07 26 AV8 +0.02 88 79 0.99 25 AV5 +0.02 0.69 20 AV6 +0.02 88 81 0.98 25 AV3 +0.00 0.96 24 AV4 -0.02 2.50 36 AV5 +0.02 1.19 27 AV6 +0.02 88 83 0.76 22 AV3 +0.00 88 85 0.70 21 AV5 +0.05 0.68 20 AV6 +0.02 88 87 0.78 22 AV3 +0.00 0.80 22 AV4 +0.08 0.73 21 AV6 +0.07 88 89 1.79 32 AV4 +0.03 1.30 28 AV5 +0.05 1.42 29 AV6 +0.02 0.73 21 AV7 +0.02 88 91 0.69 20 AV3 +0.02 1.26 28 AV4 +0.03 0.93 24 AV5 +0.02 2.29 35 AV6 +0.05 0.83 23 AV7 +0.02 88 93 1.40 29 AV5 +0.05 2.49 36 AV6 +0.02 88 95 1.35 29 AV3 +0.00 2.63 37 AV4 +0.03 1.40 29 AV5 +0.02 88 97 0.97 24 AV4 +0.05 0.66 20 AV5 +0.05 0.74 21 AV6 +0.02 88 99 0.81 22 AV3 +0.05 1.46 30 AV4 +0.05 1.30 28 AV6 +0.05 88 101 1.65 31 AV3 +0.02 0.72 21 AV4 +0.05 1.49 30 AV5 +0.05 1.33 28 AV6 +0.07 0.81 22 AV7 +0.02 88 107 0.80 22 AV3 +0.05 0.95 24 AV7 +0.05 88 109 1.25 28 AV3 +0.02 0.72 21 AV4 +0.03 89 68 0.68 20 AV5 +0.05 89 70 0.93 24 AV7 +0.00 89 72 0.84 23 AV4 +0.00 2.60 37 AV5 +0.00 1.21 27 AV6 +0.02 0.83 23 AV7 +0.02 0.68 20 AV3 +0.02 89 74 0.73 21 AV3 +0.05 0.74 21 AV4 +0.03 1.58 31 AV5 +0.05 2.68 37 AV6 +0.07 1.84 32 AV7 +0.02 89 78 1.06 26 AV4 +0.03 0.91 24 AV5 +0.02 89 80 0.75 21 AV7 +0.02 89 82 1.79 32 AV4 +0.03 0.82 22 AV5 +0.00 0.86 23 AV6 +0.02 2.55 37 AV7 +0.02 89 84 0.90 24 AV5 +0.02 1.41 29 AV6 +0.02 2.41 36 AV7 +0.02 89 92 0.65 20 AV4 +0.05 0.74 21 AV6 +0.05 1.17 27 AV3 +0.02 89 96 0.68 20 AV3 +0.07 89 102 1.87 33 AV2 +0.02 1.94 33 AV3 +0.05 1.70 32 AV4 +0.08 0.86 23 AV6 +0.05 0.76 22 AV7 +0.02 89 106 0.76 21 AV4 +0.08 90 75 1.19 27 AV6 +0.00 0.98 25 AV7 +0.02 90 79 1.36 29 AV5 +0.02 90 83 0.79 22 AV5 +0.09 90 85 0.78 22 AV4 +0.03 2.51 37 AV5 +0.02 1.69 31 AV6 +0.05 1.55 30 AV7 +0.05 90 87 0.94 24 AV3 +0.02 0.90 23 AV4 +0.05 2.27 35 AV5 +0.05 1.74 32 AV6 +0.05 90 91 1.47 30 AV3 +0.00 1.89 33 AV4 +0.05 2.86 38 AV5 +0.02 3.01 39 AV6 +0.02 0.70 21 AV7 +0.02 90 97 1.46 30 AV2 +0.00 1.64 31 AV3 +0.02 2.44 36 AV4 +0.03 2.92 38 AV6 +0.02 1.77 32 AV7 +0.02 90 99 1.09 26 AV2 +0.00 1.21 27 AV3 +0.02 1.99 34 AV4 +0.05 1.59 31 AV5 +0.02 90 103 1.93 33 AV3 +0.00 1.77 32 AV4 +0.05 1.88 33 AV5 +0.07 1.60 31 AV6 +0.05 1.56 30 AV7 +0.00 90 105 2.38 36 AV6 +0.07 2.95 39 AV7 +0.02 0.96 24 AV4 +0.05 2.31 35 AV5 +0.05 91 64 1.05 25 AV5 +0.00 91 66 0.84 23 AV5 +0.05 91 68 0.76 22 AV7 +0.00 0.87 23 AV6 +0.00 0.84 23 AV5 +0.05 91 70 0.98 25 AV6 -0.02 0.95 24 AV5 -0.05 91 72 1.40 29 AV7 +0.00 1.99 34 AV6 -0.02 3.01 39 AV5 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 51 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 6 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 1.06 26 AV3 +0.00 91 80 1.47 30 AV7 +0.00 2.24 35 AV5 -0.03 1.65 31 AV4 +0.00 91 82 1.14 26 AV7 -0.02 1.17 27 AV6 +0.00 1.66 31 AV5 -0.03 1.90 33 AV4 -0.05 91 90 1.41 29 AV7 +0.00 2.86 38 AV6 +0.02 2.64 37 AV5 +0.02 1.33 28 AV4 +0.00 91 92 1.28 28 AV7 +0.00 1.89 33 AV6 +0.02 0.66 20 AV5 +0.05 1.57 30 AV4 +0.03 1.79 32 AV3 +0.02 91 96 1.66 31 AV7 +0.02 1.92 33 AV6 +0.05 1.98 33 AV4 +0.03 2.61 37 AV3 +0.07 0.68 20 AV2 -0.02 91 98 1.36 29 AV6 +0.05 1.85 33 AV4 +0.03 2.20 35 AV3 +0.00 91 100 0.99 25 AV3 +0.00 0.79 22 AV7 +0.00 1.67 31 AV6 +0.02 91 106 0.95 24 AV6 +0.00 2.44 36 AV4 +0.00 0.79 22 AV3 -0.05 91 108 0.72 21 AV7 +0.02 2.78 38 AV6 +0.00 2.00 34 AV5 -0.03 0.65 20 AV4 +0.00 0.72 21 AV3 +0.00 91 110 0.93 24 AV6 +0.00 2.71 38 AV5 +0.00 1.39 29 AV4 +0.00 91 112 1.09 26 AV2 +0.02 91 116 1.08 26 AV6 -0.05 0.78 22 AV5 -0.03 0.70 21 AV4 +0.00 92 69 0.87 23 AV6 +0.00 92 79 2.26 35 AV5 +0.00 0.76 22 AV3 -0.02 92 83 2.34 36 AV6 +0.02 2.23 35 AV5 -0.03 1.94 33 AV4 -0.05 0.82 22 AV3 -0.02 0.66 20 AV2 -0.05 92 85 1.57 30 AV7 +0.00 1.32 28 AV6 +0.00 1.53 30 AV5 -0.03 1.28 28 AV4 +0.00 1.59 31 AV3 -0.02 92 87 0.88 23 AV6 +0.02 1.31 28 AV5 +0.00 0.76 21 AV4 +0.00 0.65 20 AV3 -0.02 92 89 1.50 30 AV6 +0.00 0.73 21 AV5 +0.00 1.19 27 AV4 -0.02 92 99 2.61 37 AV6 +0.00 1.54 30 AV5 +0.00 1.46 30 AV4 +0.00 0.96 24 AV3 -0.02 2.34 36 AV7 +0.00 92 101 0.99 25 AV5 +0.00 1.12 26 AV3 +0.02 92 103 0.88 23 AV6 +0.09 1.02 25 AV5 +0.00 2.10 34 AV4 +0.00 2.06 34 AV3 +0.00 92 105 2.93 39 AV5 +0.02 1.39 29 AV4 +0.00 0.99 25 AV6 +0.03 93 70 0.98 25 AV6 +0.00 0.97 24 AV5 +0.02 93 78 1.56 30 AV7 +0.00 1.04 25 AV6 +0.00 1.97 33 AV5 +0.02 0.68 20 AV4 +0.00 0.73 21 AV2 -0.02 93 82 1.56 30 AV7 +0.00 0.92 24 AV6 +0.00 1.17 27 AV5 -0.03 1.06 26 AV4 -0.02 93 88 2.34 36 AV7 +0.00 1.18 27 AV6 +0.00 1.28 28 AV5 +0.02 93 100 0.65 20 AV6 +0.05 93 102 2.45 36 AV6 +0.00 2.92 39 AV5 +0.00 2.54 37 AV4 +0.00 0.65 20 AV3 -0.02 93 104 1.62 31 AV3 -0.02 1.85 33 AV7 +0.00 1.20 27 AV4 -0.02 93 106 1.21 27 AV7 +0.00 0.76 22 AV6 -0.02 1.37 29 AV4 +0.00 0.68 20 AV3 -0.02 93 108 0.92 24 AV6 +0.00 93 110 1.71 32 AV5 +0.00 1.20 27 AV4 +0.00 93 112 0.72 21 AV6 -0.02 0.85 23 AV7 +0.00 94 67 1.39 29 AV7 +0.00 1.36 29 AV6 +0.00 94 71 2.39 36 AV7 +0.02 1.15 27 AV6 +0.00 0.88 23 AV5 +0.00 1.21 27 AV4 +0.03 94 77 0.99 25 AV7 -0.02 2.83 38 AV6 +0.00 0.92 24 AV5 +0.00 1.09 26 AV4 -0.02 94 79 0.91 24 AV6 +0.00 94 81 1.71 32 AV7 -0.02 1.82 32 AV6 +0.00 1.29 28 AV5 -0.05 94 95 2.60 37 AV6 +0.02 1.25 28 AV4 +0.03 1.10 26 AV3 +0.02 1.72 32 AV7 -0.02 94 97 0.76 21 AV6 +0.02 0.90 24 AV4 +0.03 94 101 0.83 23 AV7 +0.02 1.13 26 AV6 +0.07 2.27 35 AV5 +0.09 0.69 20 AV4 +0.05 0.83 23 AV3 +0.02 0.95 24 AV2 +0.00 94 103 0.71 21 AV2 -0.05 1.77 32 AV5 -0.03 2.87 38 AV4 -0.02 2.80 38 AV3 -0.02 2.54 37 AV6 +0.00 95 68 0.76 22 AV5 +0.02 95 74 0.80 22 AV6 +0.00 95 78 0.89 23 AV7 +0.00 0.99 25 AV5 -0.05 95 80 1.04 25 AV6 +0.00 0.84 23 AV5 +0.00 2.00 34 AV4 +0.00 95 82 1.47 30 AV7 +0.02 1.03 25 AV6 +0.02 2.18 35 AV5 -0.03 2.48 36 AV4 -0.02 95 84 2.56 37 AV5 +0.00 2.09 34 AV4 -0.02 0.88 23 AV3 -0.02 0.92 24 AV2 -0.05 95 88 1.69 31 AV6 +0.02 2.20 35 AV4 -0.02 1.75 32 AV7 +0.00 95 96 1.88 33 AV6 +0.00 0.71 21 AV4 +0.00 0.65 20 AV3 +0.02 95 98 1.33 28 AV6 +0.02 1.95 33 AV5 +0.05 0.86 23 AV3 +0.00 95 100 2.70 37 AV5 +0.00 1.30 28 AV7 +0.00 95 104 1.18 27 AV5 -0.03 0.74 21 AV3 +0.02 95 106 0.75 21 AV6 +0.00 96 65 0.74 21 AV5 +0.02 96 67 0.77 22 AV7 +0.00 1.46 30 AV6 +0.00 1.48 30 AV5 +0.00 96 71 2.17 35 AV7 +0.00 2.03 34 AV6 -0.02 2.53 37 AV5 +0.00 0.82 22 AV4 -0.02 96 75 0.79 22 AV8 +0.02 2.89 38 AV6 +0.10 2.50 36 AV5 +0.00 1.07 26 AV4 -0.05 96 79 1.50 30 AV7 +0.00 2.08 34 AV4 +0.00 2.55 37 AV3 +0.00 96 81 0.93 24 AV5 +0.00 96 91 1.17 27 AV7 +0.00 2.54 37 AV6 +0.02 1.85 33 AV4 +0.03 0.98 25 AV3 +0.00 96 95 1.76 32 AV6 +0.09 1.18 27 AV5 +0.05 96 97 0.93 24 AV4 +0.05 96 103 1.59 31 AV6 -0.02 0.84 23 AV4 -0.02 2.54 37 AV3 +0.00 0.89 23 AV2 -0.02 96 105 1.80 32 AV7 +0.02 2.32 36 AV6 +0.05 1.89 33 AV5 +0.07 97 66 0.76 22 AV2 +0.00 97 68 0.99 25 AV7 +0.00 1.74 32 AV6 +0.07 1.03 25 AV5 +0.00 2.08 34 AV4 +0.00 97 70 0.64 20 AV6 +0.02 97 72 0.72 21 AV7 +0.00 2.77 38 AV6 +0.00 3.01 39 AV5 +0.00 1.05 25 AV4 +0.03 97 74 2.07 34 AV7 +0.05 1.12 26 AV5 +0.00 1.07 26 AV3 -0.02 97 82 0.82 23 AV7 +0.00 1.48 30 AV4 +0.03 97 96 1.07 26 AV6 +0.00 2.52 37 AV5 +0.00 1.95 33 AV4 -0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 52 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 7 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 1.42 29 AV3 -0.02 97 98 1.39 29 AV5 -0.03 1.90 33 AV4 -0.02 1.85 33 AV3 -0.02 1.64 31 AV2 +0.00 97 108 0.67 20 AV5 +0.02 98 71 0.90 24 AV5 +0.00 0.74 21 AV3 -0.02 98 73 2.58 37 AV7 -0.05 1.27 28 AV4 +0.03 0.81 22 AV3 -0.02 98 77 2.91 38 AV6 -0.02 1.85 33 AV4 -0.02 98 79 1.63 31 AV3 -0.02 1.24 27 AV6 +0.00 2.13 34 AV5 +0.00 0.71 21 AV4 -0.02 98 81 0.71 21 AV8 +0.00 1.86 33 AV7 -0.02 2.03 34 AV6 +0.00 1.20 27 AV5 -0.03 1.03 25 AV3 +0.00 98 93 0.91 24 AV7 -0.02 1.15 27 AV6 -0.02 2.49 36 AV4 -0.02 0.70 21 AV3 +0.00 0.90 24 AV5 +0.00 98 99 1.79 32 AV4 +0.00 1.66 31 AV3 -0.02 98 105 1.28 28 AV7 +0.00 2.11 34 AV6 +0.00 1.40 29 AV5 +0.00 2.95 39 AV4 +0.00 1.62 31 AV3 -0.02 0.74 21 AV2 -0.02 98 107 0.90 24 AV6 +0.02 99 68 0.66 20 AV7 +0.00 1.34 29 AV6 +0.00 0.77 22 AV4 -0.02 99 72 1.42 29 AV6 +0.00 1.44 29 AV5 +0.02 0.71 21 AV4 +0.03 99 76 1.42 29 AV6 +0.05 2.82 38 AV5 +0.02 1.92 33 AV4 +0.00 99 78 1.40 29 AV6 +0.02 0.64 20 AV4 +0.03 0.93 24 AV3 +0.00 0.90 24 AV2 +0.00 99 80 1.15 27 AV4 -0.02 99 82 0.74 21 AV5 +0.00 99 96 1.22 27 AV5 -0.03 0.64 20 AV4 +0.00 0.99 25 AV3 +0.00 99 98 0.85 23 AV8 +0.05 0.98 25 AV7 +0.00 99 104 0.89 23 AV7 +0.02 0.89 23 AV5 +0.05 99 106 0.80 22 AV7 +0.02 2.03 34 AV6 +0.02 1.06 26 AV5 +0.02 100 67 0.69 20 AV6 -0.02 0.66 20 AV5 -0.05 100 69 2.08 34 AV7 +0.02 0.97 24 AV6 +0.00 100 71 1.59 31 AV7 +0.00 2.96 39 AV6 +0.00 1.48 30 AV5 +0.02 100 73 1.03 25 AV8 +0.05 2.67 37 AV6 +0.02 2.23 35 AV5 +0.00 0.76 22 AV3 -0.05 100 75 2.71 38 AV7 +0.02 2.31 35 AV6 +0.05 2.34 36 AV5 -0.03 2.10 34 AV4 -0.05 2.59 37 AV3 +0.02 1.76 32 AV2 +0.00 100 77 1.10 26 AV8 +0.00 2.64 37 AV7 -0.02 2.87 38 AV6 +0.00 0.99 25 AV5 -0.03 1.23 27 AV4 -0.02 0.72 21 AV3 +0.00 100 79 2.49 36 AV6 +0.00 1.33 28 AV4 -0.02 2.33 36 AV3 +0.00 2.07 34 AV2 -0.02 100 81 2.25 35 AV7 -0.02 2.78 38 AV6 -0.02 3.07 39 AV5 -0.05 0.70 21 AV3 -0.02 100 91 2.04 34 AV6 +0.02 2.36 36 AV5 -0.03 0.98 25 AV7 +0.00 1.02 25 AV4 -0.02 100 95 1.95 33 AV6 +0.05 0.88 23 AV5 +0.02 0.70 21 AV2 +0.00 100 99 1.47 30 AV7 +0.00 0.86 23 AV6 +0.00 100 105 1.38 29 AV7 +0.00 1.61 31 AV6 +0.00 2.49 36 AV5 -0.03 1.56 30 AV4 -0.02 100 107 0.95 24 AV7 +0.02 1.75 32 AV6 +0.03 0.74 21 AV4 +0.03 0.98 25 AV3 +0.00 101 74 2.24 35 AV6 +0.00 3.04 39 AV5 +0.00 1.07 26 AV4 -0.02 0.78 22 AV3 -0.02 101 78 0.99 25 AV7 -0.02 1.02 25 AV6 +0.00 0.71 21 AV5 -0.03 101 88 2.30 35 AV6 -0.02 2.85 38 AV5 -0.03 0.88 23 AV4 -0.02 2.39 36 AV3 -0.02 1.46 30 AV2 +0.00 101 94 1.08 26 AV8 +0.02 1.12 26 AV7 +0.00 0.65 20 AV5 -0.03 101 96 0.74 21 AV2 +0.00 1.20 27 AV3 +0.00 101 98 0.78 22 AV8 +0.02 101 100 1.19 27 AV6 +0.02 102 71 1.00 25 AV7 +0.00 2.65 37 AV6 -0.02 2.40 36 AV5 +0.00 0.87 23 AV4 -0.02 102 73 0.74 21 AV6 +0.00 1.33 28 AV5 +0.02 102 77 2.36 36 AV6 -0.02 2.31 35 AV5 +0.00 1.48 30 AV4 +0.00 102 79 0.95 24 AV8 +0.05 1.32 28 AV7 +0.02 2.07 34 AV5 +0.05 102 91 0.69 20 AV6 +0.02 1.75 32 AV5 +0.00 1.60 31 AV4 +0.00 102 95 0.71 21 AV7 +0.00 2.45 36 AV6 +0.02 0.94 24 AV4 -0.02 102 97 1.25 28 AV4 +0.03 102 99 1.07 26 AV5 +0.02 1.53 30 AV4 +0.03 103 72 0.86 23 AV6 -0.02 2.03 34 AV5 +0.00 2.61 37 AV4 +0.00 103 78 0.77 22 AV6 +0.00 2.95 39 AV5 -0.03 1.35 29 AV4 -0.05 1.00 25 AV3 -0.02 0.68 20 AV2 +0.00 103 80 0.98 25 AV7 +0.05 1.23 27 AV6 +0.05 103 82 0.82 22 AV8 +0.02 2.17 35 AV7 +0.00 2.13 34 AV6 +0.02 1.74 32 AV5 +0.02 1.58 31 AV4 +0.05 103 92 2.21 35 AV7 +0.00 3.06 39 AV6 +0.02 1.61 31 AV5 +0.02 1.21 27 AV4 -0.02 1.84 33 AV3 +0.00 103 96 2.86 38 AV7 +0.02 1.76 32 AV6 +0.00 2.39 36 AV5 +0.00 103 100 1.89 33 AV6 +0.02 1.42 29 AV5 +0.00 1.10 26 AV4 +0.00 0.78 22 AV3 +0.00 103 104 0.80 22 AV4 -0.02 103 106 0.86 23 AV5 +0.00 104 71 0.75 21 AV5 -0.03 104 73 0.81 22 AV6 +0.00 0.75 21 AV4 -0.02 104 75 2.53 37 AV7 +0.02 2.08 34 AV6 +0.07 2.18 35 AV4 +0.00 1.95 33 AV3 +0.00 104 77 1.24 27 AV6 +0.00 1.66 31 AV4 -0.02 104 79 0.89 23 AV4 -0.02 104 91 0.87 23 AV7 +0.00 1.36 29 AV6 +0.02 0.92 24 AV5 -0.03 0.82 22 AV4 -0.02 1.12 26 AV3 -0.02 1.37 29 AV2 -0.02 104 97 1.03 25 AV6 +0.02 1.10 26 AV5 +0.00 1.84 33 AV4 +0.00 104 99 0.65 20 AV4 +0.05 104 105 1.27 28 AV7 +0.05 1.14 26 AV6 +0.05 0.87 23 AV5 +0.00 105 72 1.50 30 AV5 +0.02 1.29 28 AV4 +0.03 105 74 2.34 36 AV6 +0.02 2.78 38 AV5 +0.00 1.43 29 AV4 -0.02 0.68 20 AV3 +0.00 105 76 1.04 25 AV7 +0.02 1.88 33 AV6 +0.00 1.46 30 AV5 +0.00 2.02 34 AV4 +0.00 105 78 0.77 22 AV6 +0.00 105 80 0.86 23 AV7 -0.02 0.85 23 AV6 -0.02 1.15 27 AV5 -0.03 105 82 1.39 29 AV6 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 53 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 8 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 2.11 34 AV5 -0.03 1.77 32 AV4 +0.00 0.78 22 AV3 -0.05 105 96 0.97 24 AV5 +0.02 105 98 1.07 26 AV6 +0.00 1.02 25 AV5 +0.00 105 100 0.76 22 AV5 +0.00 0.69 20 AV4 +0.00 106 71 1.08 26 AV5 +0.02 106 73 0.71 21 AV8 +0.02 2.71 38 AV6 +0.00 2.25 35 AV5 +0.00 1.19 27 AV4 +0.00 106 75 0.68 20 AV8 +0.02 2.17 35 AV7 +0.00 0.81 22 AV6 +0.02 1.33 28 AV5 +0.00 106 77 0.82 22 AV6 +0.00 1.53 30 AV5 +0.02 1.28 28 AV4 -0.02 106 93 2.03 34 AV6 +0.05 1.83 32 AV5 +0.05 1.56 30 AV4 +0.03 106 95 2.26 35 AV4 +0.00 106 97 1.03 25 AV3 +0.00 106 99 0.66 20 AV4 -0.02 1.27 28 AV6 +0.02 0.72 21 AV5 +0.00 106 101 0.69 20 AV5 +0.00 1.09 26 AV4 -0.02 106 103 1.15 27 AV6 +0.00 0.98 25 AV5 -0.03 107 68 1.51 30 AV7 +0.00 0.93 24 AV6 -0.02 107 70 1.00 25 AV5 +0.00 1.46 30 AV4 -0.02 0.71 21 AV3 -0.02 107 76 0.67 20 AV6 +0.00 107 86 0.79 22 AV7 +0.02 1.42 29 AV6 -0.02 0.68 20 AV5 -0.03 1.02 25 AV4 -0.02 0.85 23 AV3 -0.02 107 90 2.54 37 AV7 +0.00 1.62 31 AV6 +0.00 2.47 36 AV5 -0.03 0.88 23 AV4 -0.02 107 96 1.61 31 AV7 +0.07 0.75 21 AV6 +0.05 0.76 22 AV3 +0.02 107 98 0.73 21 AV5 +0.00 0.66 20 AV3 +0.00 107 100 1.13 26 AV5 +0.02 0.81 22 AV4 -0.02 107 102 0.68 20 AV6 +0.02 0.90 24 AV3 +0.00 108 71 1.21 27 AV6 +0.00 108 75 0.87 23 AV7 +0.02 0.89 23 AV6 +0.05 2.89 38 AV5 +0.00 108 77 1.61 31 AV7 +0.02 2.56 37 AV6 +0.02 1.42 29 AV5 +0.00 0.89 23 AV4 -0.02 0.89 23 AV3 +0.00 108 81 0.65 20 AV8 +0.02 1.37 29 AV7 +0.02 0.75 21 AV6 +0.02 0.91 24 AV5 +0.02 0.66 20 AV4 -0.02 1.54 30 AV3 +0.00 0.88 23 AV2 +0.00 108 91 0.92 24 AV7 +0.00 2.19 35 AV6 +0.00 2.71 38 AV5 +0.02 2.14 34 AV4 +0.00 1.85 33 AV3 -0.05 1.08 26 AV2 -0.02 108 93 0.77 22 AV4 -0.02 1.49 30 AV3 +0.00 0.71 21 AV2 +0.00 0.78 22 AV7 +0.02 1.37 29 AV6 +0.02 1.04 25 AV5 +0.00 108 99 2.02 34 AV6 +0.02 2.12 34 AV5 -0.03 1.71 32 AV3 +0.00 1.35 29 AV2 -0.02 108 101 1.11 26 AV3 +0.02 1.25 28 AV2 +0.00 108 103 1.02 25 AV4 -0.05 0.97 24 AV3 -0.05 108 105 0.96 24 AV6 +0.00 109 68 0.87 23 AV6 +0.00 1.02 25 AV5 +0.05 1.23 27 AV3 +0.02 2.50 36 AV2 +0.00 109 70 0.67 20 AV6 +0.02 109 76 1.15 27 AV7 +0.02 1.74 32 AV6 +0.07 1.36 29 AV4 +0.05 109 82 2.55 37 AV5 +0.02 0.77 22 AV4 +0.00 1.31 28 AV3 +0.00 0.78 22 AV2 -0.02 1.45 29 AV7 +0.02 2.88 38 AV6 +0.02 109 88 2.26 35 AV7 +0.00 2.08 34 AV6 -0.02 1.34 28 AV5 -0.03 0.74 21 AV4 -0.02 109 92 1.09 26 AV7 +0.00 1.32 28 AV6 +0.00 0.89 23 AV4 +0.00 1.32 28 AV3 +0.00 109 94 0.76 22 AV6 +0.02 109 98 0.87 23 AV6 +0.00 109 100 3.01 39 AV7 +0.05 1.38 29 AV5 +0.05 1.34 28 AV4 +0.05 110 69 1.55 30 AV7 +0.00 1.88 33 AV6 -0.02 0.82 22 AV5 +0.00 110 73 1.31 28 AV5 +0.00 1.13 26 AV4 -0.02 0.79 22 AV3 +0.02 0.90 24 AV2 -0.05 110 75 1.30 28 AV5 +0.00 1.18 27 AV4 +0.00 1.09 26 AV3 +0.02 110 77 1.60 31 AV6 +0.05 2.50 36 AV5 +0.02 2.66 37 AV4 +0.00 1.58 31 AV3 +0.02 110 79 1.45 29 AV7 +0.05 2.86 38 AV6 +0.07 1.37 29 AV5 +0.02 0.79 22 AV4 +0.03 110 81 1.25 28 AV5 +0.00 0.75 21 AV4 +0.00 110 93 1.33 28 AV4 -0.02 1.84 33 AV3 -0.02 0.81 22 AV2 -0.02 1.19 27 AV6 +0.02 0.75 21 AV5 -0.03 110 99 0.72 21 AV4 -0.02 110 101 1.01 25 AV4 -0.02 110 103 0.69 20 AV6 +0.00 1.70 32 AV5 +0.00 0.86 23 AV4 -0.02 0.90 24 AV3 -0.02 111 70 0.68 20 AV5 +0.05 111 72 1.46 30 AV6 +0.00 111 74 1.48 30 AV6 +0.00 0.97 24 AV5 -0.03 111 76 0.87 23 AV6 +0.00 0.67 20 AV5 -0.03 111 80 1.61 31 AV7 +0.00 1.00 25 AV6 +0.00 1.51 30 AV5 -0.05 111 82 0.76 22 AV7 +0.00 2.22 35 AV5 +0.00 1.43 29 AV4 -0.02 111 86 2.18 35 AV4 +0.00 1.36 29 AV3 -0.02 1.31 28 AV2 -0.02 1.41 29 AV6 +0.00 1.71 32 AV5 +0.00 111 98 0.83 23 AV5 +0.05 112 69 0.78 22 AV6 +0.00 112 73 0.69 20 AV4 -0.02 112 75 1.01 25 AV5 +0.02 112 77 1.15 27 AV6 +0.05 1.03 25 AV5 -0.03 112 79 1.08 26 AV7 +0.00 2.01 34 AV5 +0.00 0.94 24 AV4 -0.02 0.75 21 AV3 -0.02 112 81 0.93 24 AV6 +0.00 1.23 27 AV5 -0.03 112 83 1.21 27 AV7 +0.00 1.23 27 AV6 +0.00 1.06 26 AV5 -0.03 2.35 36 AV4 -0.07 0.85 23 AV3 -0.05 112 87 2.05 34 AV7 +0.00 2.30 35 AV6 +0.00 1.92 33 AV5 +0.00 1.23 27 AV4 -0.02 1.37 29 AV3 -0.02 1.01 25 AV2 -0.02 112 93 0.84 23 AV7 +0.02 0.81 22 AV6 +0.07 0.65 20 AV5 +0.00 1.15 27 AV4 +0.00 1.20 27 AV3 -0.02 0.78 22 AV2 +0.00 112 95 0.78 22 AV2 +0.02 0.83 23 AV7 -0.02 1.83 32 AV6 +0.02 0.76 21 AV5 +0.00 112 97 1.34 28 AV3 +0.02 112 99 0.98 25 AV6 +0.07 1.51 30 AV3 +0.02 1.53 30 AV2 +0.02 112 103 1.87 33 AV5 +0.07 0.96 24 AV4 +0.00 0.84 23 AV3 -0.02 113 74 2.27 35 AV6 +0.07 2.01 34 AV5 +0.09 2.18 35 AV4 +0.03 0.69 20 AV3 +0.05 113 76 0.86 23 AV6 +0.02 0.76 22 AV3 +0.00 113 78 1.63 31 AV7 +0.02 1.55 30 AV6 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 54 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 9 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 1.82 32 AV5 +0.00 1.07 26 AV4 +0.00 113 80 0.68 20 AV3 +0.00 1.46 30 AV7 +0.02 1.38 29 AV6 +0.02 113 88 1.20 27 AV7 +0.00 1.56 30 AV6 -0.02 1.05 25 AV5 -0.03 1.69 31 AV4 -0.02 113 90 1.50 30 AV7 +0.00 1.34 28 AV6 +0.00 1.88 33 AV5 -0.03 1.30 28 AV4 -0.05 0.92 24 AV3 -0.05 113 94 0.70 21 AV6 +0.00 0.73 21 AV5 -0.05 113 102 0.73 21 AV6 +0.02 114 67 0.74 21 AV7 +0.02 114 75 1.04 25 AV5 +0.00 114 77 1.22 27 AV3 +0.00 114 79 1.54 30 AV7 +0.00 1.85 33 AV6 +0.02 1.35 29 AV5 +0.00 0.66 20 AV4 -0.02 114 81 1.35 29 AV3 -0.02 114 87 1.25 28 AV5 -0.03 1.80 32 AV4 -0.02 1.54 30 AV3 -0.02 114 91 0.75 21 AV8 +0.05 1.26 28 AV7 +0.02 1.95 33 AV6 +0.02 2.06 34 AV5 +0.00 0.68 20 AV4 -0.05 0.84 23 AV3 -0.02 114 93 0.64 20 AV5 -0.03 114 101 2.85 38 AV5 +0.02 1.16 27 AV4 +0.00 0.90 24 AV7 +0.02 1.02 25 AV6 +0.02 115 66 1.23 27 AV7 +0.10 2.25 35 AV6 +0.12 1.35 29 AV2 +0.05 115 72 0.79 22 AV7 +0.07 1.48 30 AV6 +0.02 115 74 0.87 23 AV6 +0.02 2.13 34 AV3 +0.00 1.57 30 AV2 -0.02 115 80 1.49 30 AV7 +0.02 2.08 34 AV6 +0.00 1.98 33 AV5 -0.03 115 82 0.70 21 AV7 +0.00 1.04 25 AV6 +0.00 2.01 34 AV5 -0.03 1.27 28 AV4 -0.02 1.26 28 AV3 -0.02 115 92 0.64 20 AV6 +0.02 0.87 23 AV5 -0.03 1.33 28 AV4 -0.07 115 102 1.48 30 AV3 +0.02 1.40 29 AV2 +0.02 116 81 2.32 36 AV6 -0.02 2.88 38 AV5 -0.03 1.04 25 AV4 -0.02 0.86 23 AV3 -0.02 116 91 0.85 23 AV6 +0.00 1.14 26 AV5 +0.00 116 93 0.79 22 AV7 +0.05 0.72 21 AV6 +0.05 1.37 29 AV5 +0.00 0.79 22 AV3 -0.02 116 95 1.49 30 AV6 +0.02 1.33 28 AV5 +0.00 0.82 22 AV7 +0.02 117 68 0.79 22 AV7 +0.05 1.70 32 AV6 +0.00 117 70 0.72 21 AV7 +0.02 1.15 27 AV6 +0.00 117 76 0.96 24 AV6 +0.00 117 80 1.11 26 AV7 +0.00 1.55 30 AV6 +0.00 2.68 37 AV5 -0.03 117 92 0.75 21 AV6 +0.00 0.68 20 AV5 -0.05 0.90 24 AV4 -0.05 1.13 26 AV3 -0.05 0.94 24 AV2 -0.05 117 94 0.71 21 AV7 +0.05 2.12 34 AV6 +0.07 2.31 35 AV5 +0.07 118 73 0.64 20 AV6 +0.00 118 77 1.84 33 AV6 +0.02 1.88 33 AV5 -0.03 118 81 2.09 34 AV6 +0.00 2.47 36 AV5 -0.03 118 91 0.68 20 AV6 +0.05 1.00 25 AV5 +0.02 0.94 24 AV3 +0.00 119 72 2.22 35 AV4 +0.05 119 74 0.70 21 AV6 +0.05 119 76 1.09 26 AV7 +0.05 2.27 35 AV6 +0.05 1.21 27 AV5 +0.02 119 80 0.76 22 AV8 +0.05 1.40 29 AV7 +0.05 1.39 29 AV6 +0.00 119 88 0.79 22 AV7 +0.02 1.25 28 AV4 -0.05 0.77 22 AV3 -0.02 119 96 0.97 25 AV5 +0.12 120 79 0.97 24 AV7 +0.02 120 81 0.64 20 AV8 +0.05 1.08 26 AV7 +0.00 2.25 35 AV6 +0.00 1.34 28 AV5 -0.05 120 91 1.35 29 AV5 -0.03 0.75 21 AV4 -0.05 0.65 20 AV2 +0.00 120 93 1.41 29 AV8 +0.07 1.66 31 AV7 +0.05 0.97 25 AV6 +0.05 1.26 28 AV4 +0.03 1.17 27 AV3 +0.02 120 97 1.06 26 AV6 +0.00 120 99 0.65 20 AV7 +0.05 1.44 29 AV6 +0.00 1.42 29 AV5 -0.03 2.06 34 AV4 -0.05 0.96 24 AV3 +0.00 1.09 26 AV2 +0.00 120 103 1.64 31 AV5 -0.05 121 78 2.31 35 AV6 +0.05 0.95 24 AV5 +0.07 121 82 2.54 37 AV6 +0.00 121 90 1.62 31 AV6 +0.00 0.82 22 AV5 -0.05 0.89 23 AV4 -0.05 0.90 24 AV3 -0.05 121 92 1.87 33 AV7 +0.02 1.70 32 AV6 +0.02 0.81 22 AV4 -0.02 1.31 28 AV3 -0.02 0.85 23 AV2 -0.02 121 94 1.67 31 AV7 +0.05 2.27 35 AV6 +0.02 0.88 23 AV5 -0.03 122 79 1.00 25 AV7 +0.05 2.49 36 AV6 +0.02 2.13 34 AV5 +0.00 0.92 24 AV4 -0.05 0.90 24 AV3 -0.02 122 81 1.12 26 AV8 +0.10 1.61 31 AV7 +0.00 2.04 34 AV6 -0.02 0.92 24 AV5 -0.05 122 83 1.59 31 AV7 +0.02 0.64 20 AV6 +0.05 2.06 34 AV5 +0.02 1.29 28 AV4 -0.02 1.99 34 AV3 -0.02 0.95 24 AV2 -0.05 122 87 0.69 20 AV6 +0.02 1.24 28 AV5 -0.03 122 101 2.37 36 AV4 +0.00 1.22 27 AV3 +0.00 1.06 26 AV2 -0.02 123 72 1.40 29 AV7 +0.02 2.03 34 AV5 -0.05 123 80 0.70 21 AV8 +0.07 1.44 29 AV7 +0.05 123 88 1.18 27 AV3 -0.02 2.04 34 AV5 -0.03 123 90 0.81 22 AV8 +0.07 1.35 29 AV7 +0.02 0.87 23 AV6 +0.00 1.13 26 AV4 -0.05 1.98 33 AV3 -0.02 1.00 25 AV2 -0.05 123 92 0.77 22 AV6 +0.00 123 94 1.27 28 AV7 +0.05 1.10 26 AV6 +0.05 0.71 21 AV4 +0.00 124 63 1.29 28 AV4 +0.00 0.78 22 AV3 +0.00 124 69 2.07 34 AV7 +0.05 2.26 35 AV6 +0.02 0.87 23 AV5 +0.00 1.38 29 AV3 +0.02 1.16 27 AV2 -0.02 124 73 0.72 21 AV7 +0.02 1.40 29 AV6 +0.02 1.26 28 AV4 -0.02 124 77 0.90 24 AV7 +0.05 0.70 21 AV6 +0.05 124 87 0.82 22 AV5 -0.03 124 91 1.35 29 AV5 -0.03 2.33 36 AV4 -0.07 0.64 20 AV3 -0.05 0.77 22 AV2 +0.00 124 99 0.99 25 AV5 +0.05 0.84 23 AV4 +0.08 125 72 0.95 24 AV6 +0.02 125 76 1.35 29 AV6 +0.07 2.72 38 AV5 +0.09 1.02 25 AV4 +0.05 125 80 1.18 27 AV8 +0.10 2.78 38 AV7 +0.09 0.84 23 AV5 +0.09 125 82 1.21 27 AV7 +0.00 2.61 37 AV6 -0.02 2.18 35 AV5 -0.05 2.61 37 AV4 -0.02 125 88 2.53 37 AV7 +0.02 2.60 37 AV6 +0.02 2.54 37 AV5 -0.03 1.30 28 AV4 -0.07 125 90 1.26 28 AV7 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 55 of 86 L-2022-048

Framatome Inc.

9/13/2021 10:01:06 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 10 of 10 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 2.69 37 AV5 -0.03 2.82 38 AV4 -0.05 125 92 0.93 24 AV6 +0.02 0.69 20 AV5 -0.03 126 69 1.57 30 AV7 +0.07 0.76 22 AV6 +0.05 0.82 22 AV3 +0.02 0.79 22 AV2 +0.00 126 77 1.78 32 AV6 +0.00 2.30 35 AV5 +0.00 126 97 0.64 20 AV3 +0.02 0.64 20 AV6 +0.05 127 76 1.01 25 AV6 +0.09 0.84 23 AV5 +0.12 127 80 0.85 23 AV7 +0.02 127 88 0.81 22 AV7 +0.05 0.86 23 AV5 -0.08 1.07 26 AV3 -0.07 0.72 21 AV2 -0.07 127 90 0.99 25 AV8 +0.07 2.04 34 AV7 +0.02 2.20 35 AV6 +0.00 1.18 27 AV4 -0.02 127 92 0.64 20 AV7 +0.02 0.84 23 AV6 +0.00 0.83 23 AV3 -0.07 0.94 24 AV2 -0.02 127 96 1.35 29 AV5 +0.00 0.80 22 AV4 +0.00 128 67 0.98 25 AV2 -0.07 1.50 30 AV5 -0.08 0.82 22 AV4 -0.12 1.60 31 AV3 -0.09 128 73 1.03 25 AV6 +0.02 128 87 0.75 21 AV3 -0.02 0.74 21 AV2 +0.00 1.29 28 AV5 -0.03 0.80 22 AV4 -0.02 128 95 1.13 26 AV7 +0.05 2.64 37 AV6 +0.02 128 99 2.73 38 AV7 +0.07 1.18 27 AV6 +0.02 0.79 22 AV4 -0.02 128 117 2.63 37 AV7 +0.05 1.18 27 AV6 +0.02 1.02 25 AV8 +0.09 129 66 1.06 26 AV6 +0.07 129 74 0.64 20 AV6 +0.05 129 78 0.97 24 AV7 +0.05 1.10 26 AV6 +0.05 0.64 20 AV5 +0.02 129 86 0.97 24 AV7 +0.02 0.73 21 AV6 +0.00 129 104 1.07 26 AV7 +0.05 0.88 23 AV6 +0.00 130 79 1.61 31 AV7 +0.07 1.67 31 AV5 +0.05 130 93 0.66 20 AV4 +0.08 2.16 35 AV3 +0.00 2.34 36 AV2 -0.02 130 95 1.54 30 AV7 +0.07 2.37 36 AV6 +0.09 130 97 0.96 24 AV6 +0.07 0.75 21 AV2 +0.02 0.80 22 AV3 +0.02 131 70 1.31 28 AV4 +0.00 131 74 2.74 38 AV7 +0.07 2.12 34 AV6 +0.12 1.84 33 AV5 +0.11 1.92 33 AV4 +0.10 131 78 2.91 38 AV6 +0.05 2.13 34 AV5 +0.07 1.34 28 AV4 +0.00 131 82 0.76 21 AV8 +0.07 1.44 29 AV7 +0.02 1.01 25 AV6 -0.02 0.69 20 AV4 -0.02 131 88 0.87 23 AV7 +0.05 0.79 22 AV5 -0.03 1.23 27 AV4 -0.02 131 92 0.81 22 AV7 +0.05 0.88 23 AV5 -0.03 0.72 21 AV3 -0.02 1.74 32 AV2 -0.02 131 94 2.55 37 AV7 +0.07 0.93 24 AV6 +0.02 1.83 32 AV4 -0.05 0.74 21 AV3 -0.05 132 69 0.67 20 AV7 +0.07 1.47 30 AV6 +0.09 0.85 23 AV3 +0.07 132 71 0.66 20 AV7 +0.02 132 79 2.04 34 AV7 +0.04 2.39 36 AV6 +0.00 1.05 25 AV5 -0.03 132 81 1.38 29 AV6 +0.00 0.81 22 AV8 +0.07 0.78 22 AV7 +0.05 132 87 0.66 20 AV6 +0.02 132 93 1.69 31 AV8 +0.09 2.36 36 AV7 +0.05 1.68 31 AV6 +0.02 132 99 0.73 21 AV5 +0.09 133 68 0.92 24 AV8 +0.05 0.93 24 AV7 +0.02 1.15 27 AV6 -0.05 0.83 23 AV2 -0.05 133 70 1.25 28 AV7 -0.02 133 72 1.06 26 AV7 +0.02 0.75 21 AV3 -0.05 133 74 1.24 28 AV7 +0.04 133 76 0.68 20 AV4 +0.03 133 86 1.36 29 AV7 +0.05 1.68 31 AV6 +0.02 2.16 35 AV5 +0.00 1.29 28 AV3 -0.02 1.59 31 AV2 -0.07 133 88 0.73 21 AV6 -0.02 133 92 1.10 26 AV7 +0.02 1.99 33 AV4 -0.02 1.87 33 AV3 -0.02 1.10 26 AV2 -0.02 134 73 0.79 22 AV7 +0.02 1.15 27 AV6 -0.05 0.64 20 AV4 -0.07 134 79 2.52 37 AV6 -0.02 1.98 33 AV5 -0.08 2.96 39 AV4 -0.09 2.19 35 AV3 -0.05 134 83 1.73 32 AV7 +0.05 1.16 27 AV6 +0.02 2.87 38 AV5 -0.03 134 87 0.72 21 AV7 +0.09 2.50 36 AV6 +0.07 2.32 35 AV5 +0.02 134 97 0.75 21 AV4 -0.07 0.68 20 AV3 -0.05 135 70 1.50 30 AV4 +0.03 1.01 25 AV3 +0.00 135 74 1.06 25 AV4 +0.10 1.06 26 AV3 +0.02 135 78 1.41 29 AV6 +0.05 1.26 28 AV4 +0.00 0.98 25 AV3 +0.00 135 92 1.82 32 AV6 +0.00 1.98 33 AV5 -0.03 0.83 23 AV4 -0.05 1.42 29 AV3 -0.05 0.99 25 AV2 -0.02 135 94 1.01 25 AV7 +0.05 135 96 0.78 22 AV8 +0.07 136 75 1.52 30 AV7 +0.04 2.66 37 AV6 +0.07 1.11 26 AV5 +0.02 136 81 0.65 20 AV6 +0.07 136 85 0.67 20 AV2 -0.05 136 91 2.01 34 AV7 +0.07 1.69 31 AV5 +0.02 0.96 24 AV3 +0.00 136 93 1.62 31 AV7 +0.09 2.53 37 AV6 +0.05 1.28 28 AV4 +0.00 1.06 26 AV3 -0.02 137 84 0.69 20 AV7 +0.05 1.56 30 AV6 +0.00 1.31 28 AV4 -0.05 137 92 0.88 23 AV2 -0.07 138 79 1.19 27 AV5 -0.05 138 93 0.66 20 AV6 +0.05 139 78 0.90 24 AV6 +0.05 2.11 34 AV5 +0.00 1.14 26 AV4 -0.02 139 92 1.31 28 AV7 +0.09 Total Tubes : 784 Total Records: 2117 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 56 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 1 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 33 164 0.12 6 AV7 +0.24 34 165 0.16 8 AV2 -0.28 0.17 8 AV7 +0.25 35 6 0.20 9 AV7 -0.20 36 159 0.10 6 AV2 +0.25 36 163 0.15 8 AV7 +0.25 36 165 0.11 6 AV2 -0.27 37 6 0.25 11 AV7 -0.24 37 164 0.13 7 AV2 -0.23 38 163 0.16 8 AV2 -0.24 0.14 7 AV7 +0.25 38 165 0.13 7 AV7 +0.25 39 6 0.15 7 AV2 -0.21 0.15 7 AV7 -0.20 39 8 0.17 8 AV7 +0.20 0.10 6 AV8 -0.16 39 162 0.10 6 AV2 -0.16 39 164 0.12 6 AV8 +0.18 0.28 12 AV2 -0.24 0.19 9 AV7 +0.23 40 161 0.14 7 AV7 +0.20 40 163 0.13 7 AV2 -0.26 0.26 11 AV7 +0.22 41 6 0.12 6 AV2 -0.26 41 8 0.13 7 AV7 +0.23 41 164 0.18 9 AV7 -0.19 42 7 0.13 7 AV7 +0.02 42 9 0.11 6 AV2 -0.19 42 163 0.15 8 AV7 -0.21 43 6 0.14 7 AV2 +0.20 0.21 9 AV3 -0.29 43 162 0.12 6 AV6 +0.33 43 164 0.16 8 AV6 +0.29 0.16 8 AV7 -0.22 44 7 0.26 11 AV3 -0.20 0.18 8 AV7 +0.23 44 9 0.15 8 AV2 -0.19 44 11 0.11 6 AV8 +0.18 0.08 5 AV1 +0.05 44 161 0.09 5 AV6 +0.29 44 163 0.29 12 AV2 -0.24 0.31 12 AV3 -0.22 0.25 11 AV6 +0.29 0.19 9 AV8 +0.18 45 8 0.16 8 AV6 +0.21 0.11 6 AV7 +0.23 45 12 0.20 9 AV3 -0.19 45 160 0.13 7 AV3 -0.19 45 162 0.11 6 AV1 +0.19 0.13 7 AV2 -0.23 0.18 9 AV3 -0.21 0.13 7 AV6 +0.27 0.13 7 AV7 -0.22 0.14 7 AV8 +0.00 46 7 0.37 14 AV3 -0.22 0.27 11 AV7 +0.18 46 9 0.09 5 AV3 -0.23 0.12 6 AV7 +0.16 0.14 7 AV6 +0.20 46 11 0.13 7 AV3 -0.23 46 17 0.15 7 AV3 -0.17 46 161 0.20 9 AV2 -0.26 0.26 11 AV6 +0.23 46 163 0.16 8 AV2 -0.26 0.12 6 AV3 -0.19 0.27 11 AV6 +0.21 0.16 8 AV8 +0.20 47 8 0.17 8 AV2 -0.18 0.17 8 AV6 +0.23 47 10 0.31 12 AV3 +0.34 47 12 0.16 8 AV3 -0.27 0.12 6 AV7 +0.20 47 14 0.07 4 AV2 +0.00 0.13 7 AV3 +0.33 47 16 0.13 7 AV3 +0.32 47 24 0.17 8 AV3 +0.34 47 158 0.13 7 AV6 +0.23 47 160 0.10 5 AV1 +0.02 0.12 6 AV2 -0.23 0.12 6 AV3 -0.17 0.12 6 AV7 +0.18 47 162 0.14 7 AV2 -0.23 0.20 9 AV3 -0.26 0.30 12 AV6 +0.19 48 7 0.32 13 AV3 -0.23 0.19 9 AV7 +0.23 0.12 6 AV8 +0.18 48 9 0.24 10 AV2 -0.23 0.12 6 AV3 -0.22 0.14 7 AV6 +0.18 0.18 9 AV7 +0.20 48 11 0.17 8 AV3 -0.22 48 161 0.07 4 AV2 -0.02 0.31 12 AV6 +0.21 0.14 7 AV7 +0.21 48 163 0.42 15 AV2 -0.21 0.13 7 AV3 +0.38 49 8 0.14 7 AV2 -0.21 0.22 10 AV6 +0.21 0.21 9 AV7 +0.18 49 10 0.34 13 AV3 +0.40 49 12 0.08 5 AV2 -0.14 0.25 11 AV3 -0.23 49 14 0.12 6 AV3 +0.33 49 24 0.16 8 AV3 +0.30 49 156 0.11 6 AV3 +0.38 49 158 0.15 8 AV6 +0.23 0.17 8 AV7 +0.23 49 160 0.16 8 AV2 -0.21 0.17 8 AV7 +0.16 49 162 0.16 8 AV2 -0.22 0.16 8 AV3 -0.24 0.13 7 AV7 +0.20 50 7 0.33 13 AV2 +0.19 0.27 11 AV3 -0.19 0.29 12 AV7 +0.23 0.17 8 AV7 -0.20 50 9 0.26 11 AV7 +0.18 0.12 6 AV2 -0.20 50 11 0.14 7 AV1 -0.16 0.13 7 AV3 -0.21 0.14 7 AV7 +0.16 50 13 0.13 7 AV3 +0.35 0.15 7 AV7 +0.21 50 15 0.12 6 AV3 +0.39 50 157 0.30 12 AV6 -0.32 0.15 7 AV7 -0.16 50 159 0.17 8 AV3 +0.26 0.18 8 AV6 -0.29 0.12 6 AV7 -0.21 50 161 0.12 6 AV2 -0.24 0.34 13 AV6 +0.23 0.18 8 AV7 +0.20 50 163 0.21 9 AV2 -0.21 0.22 10 AV3 +0.38 0.18 8 AV7 -0.23 51 8 0.22 10 AV3 -0.26 0.60 19 AV6 -0.31 0.24 10 AV7 +0.23 0.11 6 AV8 +0.18 0.19 9 AV2 -0.17 51 10 0.26 11 AV3 +0.30 0.15 7 AV8 -0.14 51 14 0.23 10 AV2 -0.16 0.15 8 AV3 -0.24 51 16 0.18 8 AV3 +0.34 51 24 0.35 13 AV3 +0.28 51 156 0.15 7 AV3 +0.26 0.21 9 AV6 -0.03 51 158 0.15 7 AV3 -0.19 0.12 6 AV6 +0.21 51 160 0.14 7 AV2 -0.23 0.13 7 AV7 +0.18 51 162 0.11 6 AV1 +0.17 0.19 9 AV2 -0.26 0.25 11 AV3 -0.22 0.20 9 AV7 -0.25 0.19 9 AV7 +0.25 52 9 0.20 9 AV2 -0.18 0.25 11 AV7 +0.21 0.16 8 AV8 +0.20 52 11 0.10 6 AV1 -0.03 0.22 10 AV3 -0.24 0.17 8 AV6 +0.16 0.22 10 AV7 +0.19 52 13 0.20 9 AV2 -0.23 0.14 7 AV3 +0.33 52 17 0.11 6 AV3 -0.19 52 19 0.14 7 AV3 +0.03 52 23 0.23 10 AV3 -0.17 52 39 0.11 6 AV3 -0.05 52 151 0.15 7 AV6 +0.16 52 159 0.13 7 AV1 +0.19 0.20 9 AV6 -0.03 0.13 7 AV8 +0.21 52 161 0.37 14 AV6 +0.18 0.15 7 AV7 +0.20 53 8 0.13 7 AV1 -0.23 0.10 5 AV2 -0.20 0.22 10 AV3 -0.22 0.25 11 AV7 +0.21 0.13 7 AV8 +0.18 53 10 0.20 9 AV2 -0.19 0.31 12 AV3 +0.30 0.17 8 AV6 -0.06 53 14 0.14 7 AV2 -0.17 0.18 8 AV3 -0.25 0.13 7 AV8 +0.02 53 16 0.27 11 AV3 +0.31 0.32 13 AV6 -0.25 0.34 13 AV7 +0.00 53 24 0.24 10 AV3 +0.31 53 154 0.16 8 AV6 -0.22 53 158 0.08 5 AV2 -0.16 0.25 11 AV3 +0.03 0.18 9 AV6 -0.03 0.21 10 AV7 +0.23 53 160 0.25 11 AV2 -0.19 0.12 6 AV3 -0.20 0.17 8 AV7 +0.20 0.17 8 AV8 +0.18 53 162 0.47 16 AV3 -0.20 0.16 8 AV6 +0.23 0.21 10 AV7 -0.25 54 9 0.15 8 AV1 -0.11 0.42 15 AV2 -0.19 0.35 13 AV3 -0.20 0.19 9 AV6 +0.26 0.19 9 AV8 +0.18 54 11 0.14 7 AV2 -0.19 0.16 8 AV3 +0.03 0.15 7 AV7 +0.21 0.11 6 AV8 +0.16 54 13 0.12 6 AV1 -0.18 0.21 9 AV3 +0.30 0.15 7 AV7 +0.23 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 57 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 2 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 54 15 0.15 7 AV7 +0.18 54 29 0.15 7 AV3 -0.21 54 153 0.28 11 AV6 -0.22 54 155 0.23 10 AV6 -0.28 54 157 0.13 7 AV7 +0.18 54 159 0.09 5 AV1 +0.21 0.17 8 AV3 +0.33 0.23 10 AV6 -0.25 0.14 7 AV7 +0.20 0.10 6 AV8 +0.21 54 161 0.14 7 AV1 -0.26 0.14 7 AV2 -0.21 0.23 10 AV3 -0.20 0.51 17 AV6 +0.23 55 10 0.20 9 AV1 -0.22 0.12 6 AV7 +0.19 55 12 0.17 8 AV1 -0.17 0.12 6 AV2 -0.16 0.25 11 AV3 -0.19 0.19 9 AV6 +0.00 0.27 11 AV7 +0.00 0.22 10 AV8 -0.07 55 14 0.31 12 AV3 -0.21 55 16 0.21 10 AV3 +0.26 0.32 13 AV6 -0.06 0.44 16 AV7 -0.02 0.14 7 AV8 +0.02 55 22 0.16 8 AV6 +0.21 55 24 0.16 8 AV3 +0.28 55 146 0.16 8 AV6 +0.21 55 154 0.09 5 AV7 +0.18 55 156 0.12 6 AV6 -0.24 0.15 7 AV7 +0.23 55 158 0.11 6 AV3 -0.21 0.19 9 AV6 +0.21 0.15 7 AV7 +0.23 55 160 0.09 5 AV1 -0.14 0.26 11 AV2 -0.24 0.14 7 AV3 -0.19 0.43 15 AV7 +0.18 0.17 8 AV8 +0.18 56 9 0.14 7 AV2 -0.17 0.47 16 AV3 -0.24 0.43 15 AV7 +0.18 0.12 6 AV8 +0.23 56 11 0.13 7 AV2 -0.17 0.23 10 AV3 -0.21 0.13 7 AV6 +0.19 0.12 6 AV7 +0.18 0.11 6 AV8 +0.20 56 13 0.12 6 AV2 -0.18 0.14 7 AV3 +0.30 0.13 7 AV7 +0.19 56 15 0.26 11 AV7 +0.02 56 17 0.15 7 AV3 +0.27 0.53 17 AV7 +0.00 0.13 7 AV8 +0.00 56 23 0.13 7 AV3 -0.21 56 25 0.11 6 AV3 -0.21 56 51 0.13 7 AV3 -0.16 56 139 0.14 7 AV6 +0.18 56 145 0.14 7 AV7 +0.02 56 153 0.21 10 AV6 -0.03 56 155 0.14 7 AV6 +0.16 0.11 6 AV7 +0.16 56 157 0.11 6 AV2 -0.17 0.22 10 AV6 -0.27 0.23 10 AV7 +0.18 56 159 0.18 8 AV3 +0.30 0.27 11 AV6 -0.27 0.10 5 AV7 +0.14 0.19 9 AV8 +0.23 56 161 0.31 12 AV3 -0.18 0.15 7 AV7 -0.23 0.55 18 AV6 +0.21 0.38 14 AV6 -0.30 57 10 0.19 9 AV1 -0.15 0.17 8 AV2 -0.21 0.16 8 AV3 +0.34 0.45 16 AV6 -0.25 0.33 13 AV7 +0.14 0.22 10 AV8 +0.18 57 12 0.15 7 AV7 +0.21 0.14 7 AV3 +0.34 57 14 0.18 8 AV3 +0.03 57 16 0.10 5 AV3 -0.14 57 20 0.12 6 AV3 +0.03 57 24 0.38 14 AV3 +0.24 57 130 0.12 6 AV6 -0.27 57 144 0.33 13 AV6 +0.00 57 148 0.12 6 AV1 -0.02 57 152 0.23 10 AV6 -0.03 0.10 5 AV8 -0.29 57 154 0.12 6 AV3 +0.05 0.16 8 AV6 +0.21 0.19 9 AV7 +0.16 57 156 0.11 6 AV7 +0.23 0.17 8 AV2 -0.16 0.16 8 AV6 +0.18 57 158 0.11 6 AV1 +0.02 0.17 8 AV2 -0.17 0.25 11 AV3 -0.15 0.23 10 AV6 +0.21 0.26 11 AV7 +0.23 57 160 0.31 12 AV2 -0.19 0.20 9 AV7 +0.23 0.21 10 AV8 +0.21 58 9 0.22 10 AV3 -0.19 0.41 15 AV6 -0.24 0.47 16 AV7 +0.19 0.18 8 AV8 +0.22 58 11 0.13 7 AV2 +0.00 0.21 9 AV3 -0.21 0.22 10 AV7 +0.19 58 13 0.16 8 AV3 -0.19 0.25 11 AV7 +0.16 58 15 0.10 6 AV2 +0.19 0.15 7 AV3 -0.22 0.20 9 AV7 -0.15 58 17 0.10 6 AV3 -0.22 58 19 0.12 6 AV8 -0.02 58 23 0.15 7 AV3 -0.16 58 33 0.17 8 AV6 -0.03 0.18 8 AV7 +0.02 58 51 0.13 7 AV3 -0.16 58 65 0.11 6 AV3 +0.03 58 143 0.19 9 AV6 +0.02 58 153 0.14 7 AV6 -0.26 58 155 0.16 8 AV8 +0.02 58 157 0.15 8 AV8 -0.02 0.11 6 AV6 -0.32 0.35 13 AV7 +0.18 58 159 0.12 6 AV1 +0.05 0.12 6 AV2 -0.12 0.12 6 AV3 +0.03 0.28 12 AV6 -0.03 0.16 8 AV7 +0.18 0.13 7 AV8 +0.21 58 161 0.18 8 AV3 -0.22 59 10 0.39 15 AV7 +0.16 0.20 9 AV8 +0.18 0.62 19 AV6 -0.29 0.20 9 AV1 -0.16 0.16 8 AV2 -0.18 0.13 7 AV3 -0.19 59 12 0.11 6 AV2 -0.20 0.17 8 AV3 -0.22 0.12 6 AV6 +0.21 0.32 13 AV7 +0.18 59 14 0.09 5 AV2 -0.15 0.38 14 AV3 -0.14 0.11 6 AV6 +0.21 0.10 6 AV7 +0.21 59 16 0.15 8 AV7 +0.19 59 28 0.18 9 AV2 -0.16 59 152 0.18 8 AV8 +0.00 59 154 0.20 9 AV7 +0.02 0.15 7 AV6 -0.03 59 156 0.16 8 AV2 -0.19 0.07 5 AV3 +0.26 0.15 8 AV6 +0.23 0.14 7 AV7 +0.20 59 158 0.21 9 AV1 -0.14 0.24 10 AV2 -0.21 0.29 12 AV3 +0.03 0.18 8 AV6 +0.23 0.35 13 AV7 +0.20 59 160 0.22 10 AV1 -0.17 0.35 13 AV7 +0.20 0.28 12 AV8 +0.21 60 11 0.15 8 AV1 -0.15 0.12 6 AV2 -0.19 0.36 14 AV3 +0.27 0.17 8 AV6 -0.25 0.29 12 AV7 +0.18 0.14 7 AV8 +0.18 60 13 0.11 6 AV1 -0.16 0.16 8 AV2 -0.17 0.23 10 AV3 -0.17 0.23 10 AV7 +0.00 0.25 11 AV8 +0.05 60 15 0.14 7 AV2 +0.00 0.24 10 AV3 +0.24 60 17 0.18 8 AV3 +0.00 0.24 10 AV6 -0.21 0.15 8 AV7 -0.16 0.29 12 AV8 +0.02 60 21 0.08 5 AV1 +0.27 60 23 0.10 6 AV2 -0.18 0.20 9 AV3 -0.19 60 25 0.12 6 AV3 -0.09 0.24 10 AV7 +0.02 0.26 11 AV8 +0.02 60 29 0.17 8 AV7 +0.02 60 51 0.08 5 AV3 +0.15 60 139 0.11 6 AV6 +0.19 60 143 0.12 6 AV6 +0.16 60 145 0.17 8 AV6 +0.19 60 149 0.47 16 AV6 +0.00 60 151 0.17 8 AV6 -0.24 60 153 0.54 18 AV6 -0.24 60 157 0.14 7 AV1 +0.05 0.15 8 AV2 -0.19 0.12 7 AV3 +0.24 0.10 6 AV6 +0.21 0.25 11 AV7 +0.20 0.14 7 AV8 +0.21 60 159 0.28 12 AV1 +0.02 0.48 16 AV3 +0.32 0.35 13 AV6 +0.02 0.14 7 AV7 +0.20 0.16 8 AV8 +0.23 61 10 0.36 14 AV3 -0.14 0.22 10 AV6 -0.26 0.43 15 AV7 +0.12 0.15 7 AV8 +0.20 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 58 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 3 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.26 11 AV2 -0.16 61 12 0.14 7 AV1 -0.20 0.32 13 AV3 +0.26 0.10 6 AV6 +0.19 0.20 9 AV7 +0.19 61 14 0.09 5 AV2 -0.18 0.47 16 AV3 -0.16 0.27 11 AV6 -0.03 0.19 9 AV7 +0.23 61 16 0.11 6 AV1 +0.05 0.12 6 AV2 +0.00 0.25 11 AV3 +0.25 0.24 10 AV6 -0.03 0.14 7 AV8 +0.02 61 18 0.15 7 AV2 +0.05 61 24 0.16 8 AV3 +0.29 61 26 0.08 5 AV1 +0.00 0.08 5 AV3 -0.16 61 54 0.08 5 AV3 +0.03 61 142 0.17 8 AV6 +0.00 61 146 0.48 16 AV6 -0.03 0.40 15 AV7 +0.00 0.20 9 AV8 +0.02 61 152 0.19 9 AV6 -0.05 61 154 0.37 14 AV6 -0.05 0.39 14 AV7 +0.00 0.17 8 AV8 +0.02 61 156 0.11 6 AV3 +0.00 0.17 8 AV6 +0.00 0.23 10 AV7 +0.20 61 158 0.12 6 AV2 -0.20 0.45 16 AV3 +0.32 0.43 15 AV6 -0.24 0.18 9 AV7 +0.20 61 160 0.26 11 AV3 -0.18 0.29 12 AV7 -0.19 62 11 0.19 9 AV1 -0.18 0.15 8 AV2 -0.03 0.36 14 AV3 +0.26 0.56 18 AV6 -0.21 0.33 13 AV7 +0.21 62 13 0.09 5 AV1 -0.20 0.23 10 AV2 -0.16 0.44 16 AV3 -0.16 0.21 10 AV7 +0.00 0.22 10 AV8 +0.02 62 15 0.12 6 AV3 -0.19 0.30 12 AV7 +0.02 0.18 9 AV8 +0.02 62 17 0.20 9 AV3 -0.19 0.41 15 AV6 -0.21 0.21 9 AV7 -0.02 0.10 5 AV8 +0.02 62 19 0.46 16 AV6 -0.03 0.23 10 AV7 -0.02 62 21 0.42 15 AV6 +0.00 0.39 14 AV7 +0.02 62 23 0.17 8 AV3 -0.17 62 29 0.11 6 AV3 +0.03 0.18 8 AV6 -0.03 62 31 0.13 7 AV3 -0.20 62 37 0.15 8 AV6 -0.05 62 39 0.19 9 AV6 +0.02 0.15 8 AV7 -0.02 62 43 0.12 6 AV3 -0.21 62 131 0.16 8 AV6 +0.00 62 139 0.16 8 AV6 +0.21 62 149 0.13 7 AV2 -0.14 62 155 0.18 9 AV8 +0.00 62 157 0.14 7 AV1 -0.19 0.12 6 AV2 -0.17 0.13 7 AV6 -0.03 0.23 10 AV7 +0.23 0.32 13 AV8 +0.00 62 159 0.22 10 AV2 +0.22 0.26 11 AV3 +0.34 0.21 9 AV6 -0.23 0.15 7 AV7 +0.20 63 12 0.19 9 AV3 -0.17 0.19 9 AV7 +0.19 63 14 0.16 8 AV2 -0.16 0.34 13 AV3 -0.17 0.40 15 AV6 -0.05 0.15 7 AV3 +0.32 63 16 0.11 6 AV1 -0.02 0.18 8 AV3 +0.03 0.39 14 AV6 -0.05 0.19 9 AV7 +0.02 0.19 9 AV8 +0.02 63 18 0.10 5 AV2 +0.05 63 22 0.30 12 AV3 +0.05 0.24 10 AV6 +0.05 63 26 0.14 7 AV6 +0.16 63 32 0.11 6 AV3 -0.02 0.17 8 AV6 +0.02 63 68 0.18 9 AV2 +0.02 63 110 0.18 8 AV6 +0.02 63 150 0.29 12 AV6 -0.05 63 152 0.30 12 AV6 -0.03 0.15 8 AV7 -0.19 63 154 0.48 16 AV6 +0.00 0.31 12 AV7 +0.00 63 156 0.27 11 AV7 +0.18 0.13 7 AV1 +0.16 0.29 12 AV3 +0.25 0.18 8 AV6 +0.21 63 158 0.27 11 AV3 -0.15 0.44 16 AV7 +0.20 0.16 8 AV8 +0.19 64 11 0.38 14 AV3 -0.19 0.16 8 AV6 -0.21 0.16 8 AV7 +0.21 64 13 0.14 7 AV2 -0.19 0.10 6 AV3 +0.26 0.35 14 AV6 -0.03 0.53 17 AV7 +0.00 0.34 13 AV8 +0.00 64 15 0.20 9 AV2 +0.02 0.21 9 AV3 +0.05 0.45 16 AV6 +0.00 0.21 9 AV7 +0.02 64 17 0.12 6 AV3 -0.17 64 19 0.12 6 AV8 -0.09 64 21 0.11 6 AV3 +0.00 64 23 0.22 10 AV3 -0.19 0.17 8 AV8 +0.04 64 27 0.13 7 AV3 -0.17 0.16 8 AV6 -0.05 0.16 8 AV7 +0.00 64 31 0.14 7 AV3 -0.17 64 33 0.21 10 AV6 +0.00 64 59 0.10 6 AV3 -0.19 64 67 0.14 7 AV3 +0.00 64 101 0.17 8 AV6 +0.26 64 107 0.12 6 AV3 +0.00 64 129 0.17 8 AV6 -0.03 64 137 0.11 6 AV3 -0.18 0.15 7 AV7 -0.02 64 151 0.26 11 AV6 -0.03 64 153 0.41 15 AV6 +0.00 0.23 10 AV7 +0.05 64 157 0.12 6 AV1 -0.17 0.49 17 AV2 -0.14 0.24 10 AV3 +0.03 0.25 11 AV6 +0.00 0.10 6 AV8 +0.00 0.24 11 AV7 +0.18 64 159 0.26 11 AV2 +0.17 0.19 9 AV3 -0.15 0.26 11 AV6 -0.21 0.21 9 AV7 -0.19 65 12 0.20 9 AV1 -0.16 0.20 9 AV3 +0.28 0.12 6 AV6 -0.23 0.16 8 AV8 +0.20 0.11 6 AV2 +0.17 65 14 0.42 15 AV3 +0.03 65 16 0.10 6 AV1 -0.46 0.26 11 AV3 +0.05 65 18 0.11 6 AV3 +0.00 65 20 0.11 6 AV2 -0.17 65 22 0.15 7 AV3 -0.02 65 24 0.31 12 AV3 +0.23 0.53 18 AV6 -0.05 65 32 0.17 8 AV3 +0.00 65 34 0.14 7 AV2 +0.00 0.20 9 AV3 +0.05 0.61 19 AV6 -0.03 65 38 0.09 5 AV3 +0.00 0.12 6 AV6 +0.00 65 52 0.11 6 AV3 +0.05 0.22 10 AV6 +0.00 0.11 6 AV7 +0.02 65 62 0.11 6 AV6 +0.05 65 64 0.16 8 AV3 +0.03 65 68 0.16 8 AV3 -0.05 0.14 7 AV6 +0.02 65 86 0.12 6 AV3 +0.03 65 104 0.24 10 AV6 +0.03 65 110 0.12 6 AV6 +0.02 65 130 0.11 6 AV2 +0.04 0.34 13 AV3 +0.05 0.53 18 AV7 +0.02 65 132 0.10 6 AV6 -0.18 65 138 0.16 8 AV6 -0.18 65 144 0.18 9 AV3 +0.00 65 148 0.38 14 AV3 +0.03 65 150 0.12 6 AV1 -0.15 65 152 0.24 10 AV6 -0.03 0.24 10 AV7 -0.02 65 154 0.24 11 AV6 +0.02 65 156 0.12 6 AV2 -0.14 0.32 13 AV3 +0.25 0.19 9 AV7 -0.21 65 158 0.13 7 AV1 -0.14 0.29 12 AV8 +0.14 66 13 0.13 7 AV1 +0.00 0.39 14 AV2 +0.05 0.36 14 AV7 +0.02 0.16 8 AV8 +0.16 66 15 0.09 5 AV1 +0.00 0.17 8 AV2 +0.02 0.26 11 AV3 -0.17 0.33 13 AV6 -0.03 0.16 8 AV7 -0.16 66 17 0.14 7 AV2 +0.00 0.22 10 AV3 +0.25 0.17 8 AV6 -0.03 66 19 0.60 19 AV7 +0.00 0.20 9 AV8 +0.02 66 23 0.28 11 AV3 -0.16 66 29 0.25 11 AV6 +0.02 66 31 0.08 5 AV2 -0.45 0.17 8 AV3 -0.21 0.24 10 AV6 -0.02 66 33 0.16 8 AV6 +0.05 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 59 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 4 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 66 41 0.19 9 AV6 -0.05 66 49 0.10 5 AV6 +0.02 66 51 0.18 9 AV6 +0.02 66 57 0.11 6 AV6 +0.00 66 63 0.20 9 AV6 +0.02 66 65 0.09 5 AV3 -0.16 66 75 0.09 5 AV3 -0.14 66 89 0.14 7 AV2 -0.14 0.11 6 AV3 -0.02 66 93 0.09 5 AV3 -0.21 66 95 0.09 5 AV2 +0.02 66 99 0.17 8 AV2 +0.05 0.18 8 AV3 +0.03 0.27 11 AV6 +0.02 66 103 0.14 7 AV6 +0.05 66 109 0.13 7 AV3 -0.05 0.20 9 AV6 +0.00 66 143 0.22 10 AV3 +0.03 0.47 16 AV6 -0.03 0.20 9 AV7 +0.00 66 149 0.22 10 AV6 -0.03 66 151 0.22 10 AV3 +0.05 0.30 12 AV6 +0.00 66 153 0.33 13 AV7 +0.00 0.37 14 AV8 -0.14 66 155 0.17 8 AV1 +0.02 0.10 6 AV2 +0.04 0.16 8 AV7 -0.14 66 157 0.19 9 AV1 -0.19 0.13 7 AV2 -0.19 0.20 9 AV6 -0.03 0.57 18 AV7 -0.14 67 12 0.18 9 AV1 -0.15 0.53 18 AV3 -0.12 0.20 9 AV6 +0.00 0.15 8 AV7 +0.19 0.19 9 AV8 +0.16 67 14 0.13 7 AV1 +0.05 0.10 6 AV2 -0.18 0.17 8 AV3 +0.05 0.15 7 AV7 +0.21 0.24 10 AV8 +0.02 67 16 0.25 11 AV3 +0.05 0.55 18 AV6 -0.03 0.17 8 AV8 -0.14 67 18 0.14 7 AV7 -0.14 67 22 0.20 9 AV3 +0.00 67 34 0.13 7 AV2 -0.02 67 36 0.13 7 AV3 +0.02 0.20 9 AV6 -0.05 67 58 0.19 9 AV6 +0.02 67 68 0.27 11 AV6 +0.05 67 70 0.14 7 AV3 +0.00 67 96 0.16 8 AV3 +0.00 67 98 0.11 6 AV3 +0.00 67 100 0.18 9 AV7 +0.05 67 102 0.16 8 AV3 +0.03 67 108 0.17 8 AV2 +0.05 0.11 6 AV3 +0.00 67 112 0.15 7 AV3 +0.00 67 114 0.18 8 AV2 +0.05 0.26 11 AV6 +0.02 0.18 9 AV7 +0.00 67 120 0.16 8 AV3 +0.05 0.35 14 AV6 +0.05 67 134 0.31 12 AV6 -0.03 0.18 8 AV7 -0.02 67 148 0.10 6 AV6 +0.05 67 150 0.19 9 AV3 +0.03 67 152 0.17 8 AV1 +0.02 0.26 11 AV3 +0.03 0.40 15 AV6 +0.00 0.44 16 AV7 +0.02 67 154 0.23 10 AV3 +0.03 0.29 12 AV6 +0.00 0.21 9 AV7 +0.02 67 156 0.16 8 AV1 -0.15 0.23 10 AV2 -0.14 0.53 17 AV3 +0.23 0.18 8 AV6 -0.15 0.25 11 AV7 -0.16 0.25 11 AV8 +0.19 67 158 0.11 6 AV2 -0.21 0.26 11 AV3 +0.28 0.14 7 AV6 +0.21 0.43 15 AV7 +0.18 0.23 10 AV8 +0.21 68 13 0.17 8 AV1 -0.20 0.21 9 AV2 +0.24 0.43 15 AV3 +0.24 0.19 9 AV7 -0.19 0.21 9 AV8 +0.20 68 15 0.11 6 AV2 +0.19 0.14 7 AV3 +0.29 0.25 11 AV6 -0.07 0.34 13 AV7 -0.19 0.15 7 AV8 +0.16 68 17 0.22 10 AV3 +0.22 0.09 5 AV7 +0.05 68 23 0.23 10 AV3 +0.00 0.20 9 AV6 +0.00 68 27 0.21 9 AV6 -0.02 68 39 0.17 8 AV6 +0.02 68 41 0.21 9 AV6 -0.02 68 51 0.13 7 AV3 -0.12 68 65 0.29 12 AV3 +0.00 68 67 0.17 8 AV3 -0.02 68 93 0.14 7 AV2 +0.02 68 97 0.20 9 AV6 +0.02 68 101 0.41 15 AV6 +0.00 0.16 8 AV7 +0.00 68 109 0.34 13 AV3 +0.05 0.53 17 AV6 +0.02 0.22 10 AV7 -0.05 68 113 0.26 11 AV6 +0.02 68 143 0.11 6 AV3 +0.02 0.26 11 AV6 +0.02 0.21 9 AV8 +0.05 68 147 0.21 9 AV2 +0.00 0.39 14 AV3 +0.02 0.29 12 AV6 -0.02 68 149 0.27 11 AV3 +0.02 0.18 8 AV7 -0.02 68 151 0.16 8 AV7 +0.07 68 153 0.11 6 AV2 +0.04 0.14 7 AV8 -0.14 68 155 0.17 8 AV1 +0.02 0.61 19 AV2 +0.02 0.17 8 AV3 +0.02 68 157 0.22 10 AV1 -0.19 0.30 12 AV2 -0.19 0.28 12 AV3 +0.16 0.27 11 AV8 +0.02 0.48 17 AV7 +0.20 0.60 19 AV7 -0.23 69 14 0.12 6 AV2 +0.20 0.30 12 AV7 -0.03 0.09 5 AV8 +0.18 69 16 0.18 9 AV3 +0.02 0.21 10 AV6 +0.00 0.16 8 AV8 -0.09 69 18 0.36 14 AV6 +0.00 0.17 8 AV7 +0.00 0.23 10 AV8 +0.00 0.27 9 AV4 +0.90 69 20 0.15 8 AV2 +0.17 0.22 8 AV4 +0.75 69 24 0.20 9 AV2 +0.19 0.15 7 AV3 +0.29 0.21 8 AV4 +0.95 69 28 0.09 5 AV7 +0.00 69 34 0.12 6 AV2 +0.23 0.15 7 AV3 +0.21 69 36 0.12 6 AV3 +0.12 0.27 11 AV6 -0.04 0.15 6 AV4 +0.97 69 38 0.16 8 AV3 +0.17 69 44 0.22 7 AV4 +0.73 69 46 0.10 5 AV3 +0.03 0.14 5 AV4 +0.98 69 52 0.20 9 AV6 +0.07 0.22 10 AV7 +0.02 0.12 5 AV4 +0.96 69 56 0.21 8 AV4 +1.02 69 62 0.27 11 AV3 +0.00 0.49 17 AV6 +0.02 0.16 8 AV7 +0.02 0.30 10 AV4 +1.07 69 68 0.24 10 AV6 +0.02 69 74 0.14 7 AV3 +0.03 69 76 0.22 10 AV7 +0.00 69 78 0.32 11 AV4 +1.30 69 80 0.13 7 AV2 +0.02 69 82 0.12 6 AV2 +0.05 69 84 0.18 9 AV2 -0.14 0.16 8 AV3 +0.03 0.17 6 AV4 +0.95 69 92 0.23 8 AV4 +0.09 69 98 0.22 8 AV4 +0.07 69 100 0.11 6 AV3 +0.06 69 102 0.14 7 AV6 +0.00 69 104 0.19 9 AV3 -0.02 0.53 17 AV6 +0.00 69 110 0.14 7 AV6 +0.05 69 126 0.32 13 AV6 +0.00 69 138 0.12 6 AV6 +0.00 69 142 0.10 6 AV6 +0.00 69 148 0.10 6 AV2 +0.00 0.34 13 AV3 +0.05 69 152 0.15 8 AV1 +0.23 0.16 8 AV3 +0.00 0.22 10 AV6 +0.00 69 154 0.13 7 AV3 +0.19 0.19 9 AV7 +0.16 69 156 0.22 10 AV1 -0.17 0.55 18 AV3 +0.28 0.60 19 AV6 -0.02 0.26 11 AV7 -0.21 0.18 8 AV8 +0.21 70 13 0.19 9 AV2 +0.21 0.10 6 AV3 +0.05 70 15 0.12 6 AV1 -0.13 0.10 6 AV2 +0.22 0.41 15 AV3 +0.15 0.61 19 AV6 -0.02 0.31 12 AV7 -0.18 0.19 9 AV8 +0.18 70 17 0.09 5 AV2 -0.12 0.37 14 AV3 +0.19 0.14 7 AV6 -0.14 0.09 5 AV7 -0.09 70 21 0.16 8 AV3 +0.15 0.12 6 AV6 +0.00 70 33 0.15 7 AV3 +0.12 70 37 0.17 8 AV6 -0.04 0.23 10 AV7 +0.05 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 60 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 5 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.18 8 AV8 +0.05 70 41 0.16 8 AV3 +0.04 70 47 0.16 8 AV3 +0.00 0.20 9 AV6 +0.05 70 49 0.22 10 AV7 +0.05 70 65 0.24 10 AV6 +0.02 70 67 0.17 8 AV3 +0.02 0.30 12 AV6 +0.00 0.28 12 AV7 +0.02 70 69 0.16 8 AV2 +0.02 0.13 7 AV3 +0.02 70 77 0.16 8 AV6 +0.07 70 81 0.13 7 AV2 +0.02 70 83 0.18 8 AV2 +0.00 0.35 13 AV3 +0.02 70 85 0.15 8 AV2 +0.00 70 89 0.15 7 AV2 +0.00 70 99 0.29 12 AV3 +0.00 70 101 0.13 7 AV6 -0.02 70 107 0.14 7 AV6 +0.02 0.20 9 AV7 +0.02 70 129 0.14 7 AV3 -0.04 70 153 0.14 7 AV6 -0.13 0.11 6 AV7 +0.16 0.24 10 AV8 -0.14 70 155 0.17 8 AV3 +0.18 0.38 14 AV6 -0.02 70 157 0.33 13 AV3 -0.16 0.21 9 AV7 +0.20 71 16 0.15 7 AV2 +0.02 0.19 9 AV3 +0.16 0.24 10 AV6 -0.04 0.14 7 AV8 +0.18 71 18 0.29 12 AV3 +0.16 0.25 11 AV4 -0.26 0.09 5 AV8 +0.02 71 20 0.14 7 AV2 +0.17 0.11 6 AV3 +0.02 71 24 0.15 7 AV3 +0.18 71 28 0.14 7 AV1 +0.21 0.14 7 AV6 +0.02 71 62 0.63 19 AV6 +0.05 0.21 9 AV7 +0.00 71 76 0.23 10 AV7 +0.05 71 78 0.22 10 AV3 +0.04 71 80 0.19 9 AV2 +0.00 0.22 10 AV3 +0.04 0.22 10 AV6 +0.05 71 88 0.14 7 AV2 -0.16 71 92 0.10 6 AV2 +0.00 71 96 0.12 6 AV3 +0.00 71 100 0.15 7 AV3 +0.04 0.18 8 AV7 +0.00 71 102 0.15 8 AV7 +0.00 71 104 0.16 8 AV6 +0.02 0.06 4 AV7 -0.14 71 106 0.44 16 AV6 +0.05 0.56 18 AV7 +0.02 71 126 0.10 6 AV3 +0.02 71 128 0.15 7 AV3 +0.04 71 130 0.10 6 AV3 +0.14 0.06 4 AV7 -0.43 71 132 0.18 8 AV6 -0.16 71 150 0.12 6 AV1 +0.07 71 152 0.12 6 AV4 +0.47 71 154 0.17 8 AV3 +0.14 0.32 13 AV7 +0.02 0.27 11 AV8 +0.02 71 156 0.24 10 AV3 +0.18 0.14 7 AV8 +0.23 0.19 9 AV6 -0.14 0.15 7 AV7 -0.21 72 15 0.09 5 AV1 -0.02 0.14 7 AV2 +0.19 0.18 8 AV3 +0.20 0.12 6 AV4 +0.08 0.31 12 AV6 -0.02 0.19 9 AV5 -0.11 0.14 7 AV7 -0.14 0.23 10 AV8 +0.18 72 17 0.09 5 AV1 +0.00 0.19 9 AV3 +0.20 0.14 7 AV6 -0.19 0.11 6 AV8 +0.00 72 21 0.12 6 AV3 +0.13 0.17 8 AV7 +0.00 72 23 0.09 5 AV1 +0.02 0.18 9 AV3 +0.02 72 27 0.07 4 AV1 +0.05 0.09 5 AV2 +0.02 0.24 10 AV3 +0.02 72 65 0.28 12 AV6 +0.00 0.26 11 AV7 +0.00 72 67 0.15 7 AV6 +0.02 72 69 0.21 9 AV2 -0.02 0.14 7 AV3 +0.00 0.23 10 AV4 +0.00 0.10 5 AV6 -0.02 72 75 0.17 8 AV3 +0.00 0.16 8 AV4 +0.00 0.20 9 AV5 -0.37 0.20 9 AV6 +0.00 72 77 0.21 9 AV6 +0.02 72 79 0.16 8 AV3 +0.02 72 85 0.14 7 AV2 -0.10 72 91 0.17 8 AV7 +0.07 72 99 0.09 5 AV2 -0.38 0.17 8 AV3 +0.00 72 101 0.25 11 AV2 +0.02 0.14 7 AV3 -0.02 72 103 0.15 8 AV3 +0.00 0.20 9 AV6 +0.07 72 105 0.16 8 AV5 -0.04 72 117 0.22 10 AV6 +0.02 72 147 0.10 5 AV1 +0.02 72 151 0.46 16 AV6 +0.00 72 153 0.18 8 AV6 +0.00 0.23 10 AV8 -0.16 72 155 0.08 5 AV1 -0.10 0.13 7 AV8 +0.18 73 14 0.24 10 AV2 +0.19 73 16 0.23 10 AV6 -0.04 73 18 0.17 8 AV4 +0.10 73 20 0.12 6 AV4 +0.36 0.10 6 AV8 -0.14 73 22 0.28 12 AV3 +0.02 73 26 0.12 6 AV1 -0.15 73 36 0.09 5 AV5 +0.09 73 48 0.14 7 AV3 +0.20 73 54 0.11 6 AV4 +0.32 73 56 0.14 7 AV2 +0.02 0.24 10 AV6 +0.02 0.27 11 AV7 +0.02 73 58 0.33 13 AV4 +0.03 0.21 10 AV5 +0.00 0.19 9 AV6 +0.05 73 60 0.09 5 AV4 +0.20 73 62 0.17 8 AV6 +0.02 73 70 0.16 8 AV5 -0.03 73 76 0.54 18 AV3 +0.02 0.35 13 AV4 +0.03 0.54 18 AV6 +0.05 0.28 12 AV7 +0.00 73 80 0.12 6 AV2 -0.19 73 82 0.19 9 AV3 -0.02 73 84 0.14 7 AV2 -0.07 0.25 11 AV3 +0.02 0.11 6 AV4 +0.36 0.16 8 AV5 -0.03 73 86 0.15 7 AV2 -0.12 73 88 0.16 8 AV2 -0.16 73 94 0.13 7 AV3 +0.04 73 96 0.13 7 AV3 +0.00 0.13 7 AV5 +0.00 0.22 10 AV6 +0.02 73 98 0.26 11 AV4 +0.07 0.17 8 AV5 +0.00 0.19 9 AV6 +0.05 73 102 0.24 10 AV6 +0.00 73 104 0.13 7 AV6 +0.00 73 110 0.15 8 AV5 +0.02 73 116 0.43 15 AV6 +0.02 0.18 8 AV7 +0.05 73 144 0.14 7 AV3 -0.16 73 150 0.11 6 AV1 -0.12 0.23 10 AV6 -0.02 73 152 0.23 10 AV7 +0.00 73 154 0.14 7 AV1 -0.12 0.14 7 AV3 +0.11 0.12 6 AV6 +0.00 0.17 8 AV8 +0.26 74 15 0.12 6 AV1 +0.21 0.28 12 AV2 +0.21 0.12 7 AV3 +0.21 0.59 19 AV4 +0.03 0.13 7 AV5 -0.27 0.17 8 AV6 +0.00 0.23 10 AV7 -0.21 0.27 11 AV8 +0.20 74 17 0.15 8 AV3 -0.22 74 19 0.21 9 AV6 -0.04 74 21 0.14 7 AV3 +0.22 74 25 0.14 7 AV3 +0.05 74 27 0.14 7 AV5 -0.30 74 51 0.21 9 AV6 +0.02 0.15 7 AV7 +0.02 74 53 0.10 6 AV4 -0.02 0.15 7 AV5 -0.12 74 63 0.23 10 AV6 +0.05 0.18 8 AV7 +0.02 74 65 0.30 12 AV4 +0.06 0.36 14 AV5 -0.18 0.14 7 AV1 -0.02 0.14 7 AV2 +0.00 74 67 0.15 7 AV2 +0.05 0.28 12 AV6 +0.02 0.20 9 AV7 +0.00 74 69 0.27 11 AV4 +0.00 74 71 0.18 9 AV5 +0.00 0.14 7 AV6 +0.00 74 75 0.14 7 AV2 +0.00 0.20 9 AV3 +0.00 0.30 12 AV6 +0.02 0.17 8 AV7 +0.00 0.17 8 AV4 +0.00 0.18 9 AV5 -0.25 74 77 0.16 8 AV3 +0.16 0.14 7 AV5 -0.19 74 79 0.15 8 AV5 -0.25 0.21 9 AV6 +0.02 0.14 7 AV7 +0.02 74 83 0.13 7 AV2 -0.02 0.16 8 AV4 +0.03 0.17 8 AV5 -0.21 74 85 0.12 6 AV2 -0.14 0.41 15 AV3 +0.05 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 61 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 6 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.18 9 AV4 +0.31 0.13 7 AV6 +0.05 0.34 13 AV7 +0.02 74 91 0.15 8 AV7 +0.02 74 93 0.13 7 AV6 +0.00 0.12 6 AV7 +0.00 74 95 0.28 12 AV2 +0.00 0.13 7 AV3 +0.02 0.17 8 AV4 +0.00 74 97 0.13 7 AV2 +0.00 0.22 10 AV3 +0.00 0.25 11 AV4 +0.06 0.17 8 AV5 -0.09 0.14 7 AV7 +0.05 0.24 10 AV8 +0.02 74 99 0.17 8 AV5 +0.00 0.22 10 AV6 +0.02 0.23 10 AV7 +0.00 74 101 0.17 8 AV2 +0.02 0.20 9 AV3 +0.00 0.24 11 AV4 +0.03 0.26 11 AV5 -0.03 0.23 10 AV6 +0.02 74 103 0.11 6 AV4 +0.31 0.15 7 AV5 +0.00 74 105 0.18 8 AV6 +0.03 0.21 9 AV7 +0.02 74 107 0.23 10 AV5 -0.03 0.30 12 AV7 +0.00 74 137 0.25 11 AV2 +0.02 0.33 13 AV3 +0.02 74 151 0.21 9 AV6 +0.02 74 153 0.22 10 AV4 +0.31 0.14 7 AV5 -0.31 0.12 6 AV8 +0.00 75 16 0.12 6 AV1 -0.16 0.20 9 AV3 +0.15 0.12 6 AV7 +0.02 0.20 9 AV8 +0.16 75 18 0.19 9 AV2 +0.05 0.14 7 AV3 +0.21 0.13 7 AV4 +0.29 0.12 6 AV5 -0.23 0.17 8 AV8 +0.16 75 20 0.17 8 AV5 -0.20 75 26 0.14 7 AV1 -0.14 0.20 9 AV2 +0.00 0.18 9 AV8 +0.02 75 36 0.28 12 AV4 -0.12 0.23 10 AV5 +0.02 75 54 0.12 6 AV4 +0.23 75 60 0.15 7 AV7 +0.02 75 62 0.18 9 AV4 +0.06 75 66 0.13 7 AV1 -0.02 0.25 11 AV2 +0.02 0.43 15 AV3 +0.02 0.27 11 AV4 +0.00 0.27 11 AV5 +0.00 75 74 0.17 8 AV3 +0.00 0.18 9 AV4 +0.03 0.21 10 AV5 +0.02 0.21 10 AV6 +0.00 75 76 0.16 8 AV4 +0.03 0.24 10 AV5 +0.02 0.31 12 AV6 +0.02 0.22 10 AV7 +0.02 75 78 0.15 8 AV4 +0.23 0.21 9 AV3 -0.02 75 80 0.15 8 AV2 -0.02 75 82 0.17 8 AV3 +0.00 0.22 10 AV5 +0.02 75 84 0.18 9 AV2 +0.02 0.16 8 AV3 +0.00 0.16 8 AV5 -0.03 75 86 0.23 10 AV3 +0.00 0.21 9 AV4 +0.06 0.27 11 AV5 +0.00 0.20 9 AV6 +0.02 0.14 7 AV7 +0.02 75 88 0.18 9 AV2 +0.02 0.37 14 AV4 +0.09 0.63 19 AV5 +0.02 0.45 16 AV6 +0.00 0.20 9 AV7 +0.05 75 90 0.14 7 AV4 +0.06 75 94 0.15 7 AV4 +0.15 0.21 9 AV6 +0.05 75 98 0.18 9 AV6 +0.00 0.26 11 AV4 +0.06 0.13 7 AV5 +0.00 75 100 0.12 6 AV4 +0.03 0.32 13 AV5 +0.00 0.14 7 AV6 +0.05 0.18 9 AV7 +0.05 75 104 0.20 9 AV4 +0.06 0.29 12 AV5 +0.05 0.33 13 AV6 +0.02 0.22 10 AV7 +0.00 75 106 0.22 10 AV3 +0.05 0.22 10 AV6 +0.00 0.26 11 AV7 +0.02 0.18 8 AV8 +0.02 75 108 0.15 8 AV3 +0.02 0.14 7 AV4 +0.26 0.22 10 AV6 +0.00 0.17 8 AV7 +0.02 0.18 8 AV8 +0.02 75 126 0.11 6 AV5 +0.02 75 138 0.12 6 AV4 +0.25 75 144 0.17 8 AV3 +0.00 75 150 0.13 7 AV3 +0.02 75 152 0.32 13 AV4 +0.26 0.14 7 AV5 -0.23 0.14 7 AV7 -0.17 0.11 6 AV8 +0.14 75 154 0.19 9 AV1 -0.12 0.15 7 AV4 +0.26 0.24 10 AV5 -0.20 0.24 10 AV7 +0.16 76 17 0.19 9 AV3 +0.21 0.14 7 AV6 -0.18 0.22 10 AV8 +0.18 76 19 0.15 8 AV7 +0.02 0.21 9 AV8 +0.02 76 21 0.12 6 AV1 -0.02 0.16 8 AV2 +0.00 0.31 12 AV5 +0.02 76 23 0.21 9 AV3 +0.05 76 33 0.15 7 AV4 +0.29 76 35 0.13 7 AV5 -0.20 76 49 0.19 9 AV3 +0.02 76 61 0.29 12 AV4 +0.03 0.27 11 AV5 +0.02 0.63 19 AV6 +0.02 76 63 0.18 8 AV2 +0.00 0.57 18 AV4 +0.06 0.50 17 AV5 +0.00 76 65 0.17 8 AV1 +0.00 0.36 14 AV5 -0.22 0.52 17 AV6 +0.02 0.43 15 AV7 +0.02 0.19 9 AV8 -0.02 76 67 0.38 14 AV6 +0.05 0.14 7 AV7 +0.02 0.21 9 AV4 +0.06 0.60 19 AV5 +0.02 76 69 0.19 9 AV1 +0.05 0.34 13 AV2 +0.02 0.40 15 AV3 +0.07 0.62 19 AV5 -0.20 0.24 10 AV6 +0.02 76 71 0.14 7 AV6 +0.05 76 73 0.25 11 AV3 +0.00 0.30 12 AV4 +0.03 0.26 11 AV5 +0.00 0.30 12 AV6 +0.05 76 75 0.18 8 AV1 +0.02 0.42 15 AV2 +0.00 0.43 15 AV3 +0.02 0.56 18 AV4 +0.03 0.35 14 AV7 +0.07 0.18 9 AV8 +0.02 76 77 0.18 9 AV4 +0.14 0.45 16 AV5 -0.03 0.34 13 AV6 +0.02 0.21 9 AV7 +0.05 76 79 0.29 12 AV6 +0.02 0.15 8 AV7 +0.00 76 81 0.17 8 AV3 -0.02 0.17 8 AV5 -0.05 76 83 0.15 8 AV1 -0.02 0.20 9 AV3 +0.02 76 85 0.17 8 AV2 +0.00 0.22 10 AV3 +0.02 76 87 0.15 8 AV2 +0.00 0.17 8 AV3 +0.02 0.14 7 AV4 +0.06 0.35 13 AV5 +0.00 0.16 8 AV6 +0.02 76 89 0.16 8 AV2 -0.02 76 91 0.21 9 AV3 -0.02 0.25 11 AV4 +0.06 0.20 9 AV5 +0.02 0.20 9 AV6 +0.02 0.22 10 AV7 +0.02 76 93 0.15 7 AV3 -0.02 0.17 8 AV4 +0.19 0.18 8 AV5 +0.02 76 95 0.12 6 AV1 +0.02 0.19 9 AV2 -0.02 0.11 6 AV4 +0.08 76 97 0.13 7 AV5 +0.02 0.17 8 AV6 +0.02 0.18 8 AV7 +0.02 76 99 0.12 6 AV2 +0.00 0.17 8 AV3 +0.02 0.22 10 AV4 +0.03 0.54 18 AV5 +0.00 0.55 18 AV7 +0.02 0.37 14 AV8 +0.02 76 101 0.19 9 AV5 -0.03 0.17 8 AV6 +0.02 76 103 0.14 7 AV2 -0.02 0.17 8 AV3 +0.00 0.15 7 AV4 +0.23 76 107 0.16 8 AV2 +0.14 76 135 0.11 6 AV4 +0.22 76 139 0.13 7 AV4 +0.22 76 151 0.20 9 AV6 +0.00 0.11 6 AV7 +0.02 76 153 0.19 9 AV3 +0.05 0.21 10 AV4 +0.20 0.22 10 AV5 -0.20 0.16 8 AV7 +0.02 77 16 0.31 12 AV8 +0.16 77 18 0.12 6 AV2 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 62 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 7 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 77 20 0.15 8 AV1 +0.05 0.46 16 AV2 +0.05 0.13 7 AV3 +0.02 0.30 12 AV5 -0.22 0.62 19 AV6 -0.02 0.40 15 AV7 -0.02 0.41 15 AV8 -0.02 77 22 0.12 6 AV2 +0.02 77 24 0.48 16 AV3 +0.08 0.28 12 AV4 +0.09 0.34 13 AV5 +0.05 0.44 16 AV6 +0.00 0.16 8 AV7 +0.02 77 46 0.12 6 AV4 +0.22 77 48 0.22 10 AV6 +0.00 77 52 0.07 4 AV3 +0.17 77 62 0.14 7 AV3 +0.02 0.54 18 AV5 +0.00 0.36 14 AV6 +0.02 0.12 6 AV7 +0.00 77 64 0.20 9 AV5 +0.02 0.15 8 AV6 +0.00 0.17 8 AV7 +0.05 77 68 0.10 6 AV7 -0.05 77 70 0.14 7 AV3 +0.02 0.11 6 AV5 +0.00 77 72 0.09 5 AV6 +0.00 77 76 0.16 8 AV3 +0.02 0.37 14 AV4 +0.06 0.60 19 AV5 +0.02 0.46 16 AV6 +0.05 0.25 11 AV2 +0.02 77 78 0.20 9 AV5 +0.02 77 80 0.10 6 AV2 +0.00 0.18 9 AV3 -0.14 0.12 6 AV4 +0.03 0.12 6 AV5 -0.03 0.13 7 AV6 +0.02 77 82 0.17 8 AV3 +0.02 0.16 8 AV4 +0.22 0.48 17 AV5 +0.05 0.21 9 AV6 +0.05 77 86 0.11 6 AV4 +0.19 0.12 6 AV5 -0.08 77 90 0.20 9 AV6 +0.02 77 92 0.13 7 AV2 +0.00 0.14 7 AV3 +0.02 0.32 13 AV5 +0.05 0.27 11 AV6 +0.05 0.12 6 AV7 -0.05 77 94 0.09 5 AV2 -0.07 0.11 6 AV3 +0.00 0.11 6 AV4 +0.23 0.11 6 AV5 -0.20 0.19 9 AV6 +0.02 77 96 0.11 6 AV2 +0.05 0.13 7 AV3 +0.00 0.14 7 AV5 +0.00 0.09 5 AV6 +0.07 0.36 14 AV7 +0.00 77 98 0.15 7 AV4 +0.03 77 100 0.09 5 AV1 +0.02 0.16 8 AV2 +0.00 0.11 6 AV3 +0.02 77 104 0.12 6 AV4 -0.12 0.23 10 AV5 -0.20 77 106 0.18 8 AV5 +0.00 0.31 12 AV6 +0.02 77 110 0.14 7 AV4 +0.06 0.40 15 AV5 +0.00 77 140 0.15 7 AV5 -0.17 77 142 0.08 5 AV2 -0.05 0.15 7 AV4 +0.00 77 146 0.13 7 AV3 -0.02 77 148 0.09 5 AV1 -0.17 77 150 0.15 7 AV6 +0.00 77 152 0.16 8 AV3 -0.09 0.13 7 AV4 +0.11 0.15 7 AV7 -0.19 78 17 0.33 13 AV3 +0.24 0.17 8 AV8 +0.18 78 19 0.14 7 AV4 +0.27 78 23 0.08 5 AV1 +0.14 0.11 6 AV2 -0.05 0.18 9 AV3 +0.02 78 25 0.17 8 AV5 -0.03 78 27 0.15 8 AV5 +0.00 78 31 0.09 5 AV4 +0.21 78 43 0.09 5 AV3 +0.17 78 49 0.11 6 AV3 -0.14 78 63 0.19 9 AV4 +0.03 0.16 8 AV5 +0.00 0.18 8 AV6 +0.00 78 65 0.13 7 AV4 -0.16 0.37 14 AV6 +0.00 0.25 11 AV7 +0.00 78 69 0.14 7 AV3 +0.00 0.19 9 AV4 -0.17 0.20 9 AV5 -0.17 78 73 0.13 7 AV5 +0.02 78 75 0.27 11 AV2 +0.02 0.33 13 AV3 +0.02 0.30 12 AV4 +0.08 0.29 12 AV6 +0.02 78 77 0.21 10 AV4 +0.03 0.29 12 AV5 +0.02 78 81 0.16 8 AV2 +0.02 0.17 8 AV3 +0.00 78 83 0.20 9 AV3 +0.02 0.22 10 AV4 +0.00 0.20 9 AV5 -0.03 0.21 9 AV6 +0.02 0.12 6 AV7 +0.00 78 85 0.38 14 AV3 +0.02 0.20 9 AV4 +0.08 0.15 8 AV5 +0.05 0.11 6 AV7 +0.02 78 89 0.13 7 AV2 -0.02 0.12 6 AV3 -0.05 0.17 8 AV6 +0.00 0.11 6 AV7 +0.05 78 93 0.15 8 AV3 -0.16 0.13 7 AV7 +0.02 78 95 0.27 11 AV4 +0.03 0.16 8 AV5 +0.03 78 97 0.19 9 AV2 +0.00 0.16 8 AV3 -0.02 0.13 7 AV4 -0.12 0.32 13 AV5 -0.03 0.10 6 AV8 +0.00 78 99 0.16 8 AV2 +0.02 0.14 7 AV3 +0.02 0.23 10 AV7 +0.02 78 101 0.19 9 AV1 +0.02 0.36 14 AV2 +0.02 0.12 6 AV3 +0.05 0.09 5 AV4 +0.03 0.29 12 AV5 +0.05 0.32 13 AV6 +0.02 78 103 0.16 8 AV5 +0.00 0.12 6 AV6 -0.02 78 105 0.34 13 AV4 +0.25 0.22 10 AV5 +0.00 78 107 0.16 8 AV5 +0.00 0.11 6 AV6 +0.00 0.17 8 AV7 +0.00 78 109 0.30 12 AV5 +0.00 0.11 6 AV6 +0.05 78 113 0.14 7 AV6 +0.00 78 115 0.19 9 AV8 +0.02 78 149 0.22 10 AV5 +0.02 78 151 0.30 12 AV6 +0.02 78 153 0.13 7 AV1 -0.15 0.14 7 AV5 -0.20 0.15 7 AV6 +0.02 0.13 7 AV8 +0.18 79 18 0.13 7 AV1 +0.02 0.12 6 AV2 +0.19 0.20 9 AV6 +0.02 0.11 6 AV7 -0.21 0.12 6 AV8 +0.16 79 20 0.22 10 AV1 +0.19 0.35 13 AV5 +0.00 79 22 0.17 8 AV3 +0.02 0.16 8 AV4 +0.19 79 24 0.13 7 AV2 +0.09 0.14 7 AV3 +0.20 79 26 0.15 7 AV1 -0.24 79 32 0.15 7 AV1 +0.00 0.16 8 AV4 +0.05 79 52 0.18 8 AV6 +0.05 0.20 9 AV7 +0.02 79 54 0.14 7 AV2 +0.00 79 60 0.12 6 AV6 +0.00 0.11 6 AV3 +0.07 79 62 0.20 9 AV3 -0.02 0.19 9 AV4 +0.08 0.36 14 AV5 +0.07 79 64 0.14 7 AV3 +0.02 0.12 6 AV5 +0.16 79 66 0.17 8 AV2 +0.02 0.42 15 AV3 +0.02 0.52 17 AV6 +0.02 79 70 0.17 8 AV3 +0.02 0.22 10 AV4 +0.05 0.39 14 AV5 +0.05 0.29 12 AV6 +0.05 79 72 0.12 6 AV3 +0.05 0.19 9 AV5 +0.02 79 76 0.10 6 AV2 -0.14 0.09 5 AV3 -0.05 0.12 6 AV4 -0.12 0.13 7 AV5 -0.16 0.14 7 AV6 +0.00 79 80 0.13 7 AV3 +0.05 0.20 9 AV4 +0.00 0.27 11 AV5 +0.02 0.16 8 AV6 +0.02 79 82 0.15 8 AV3 +0.00 0.15 7 AV4 +0.05 0.43 15 AV5 +0.02 0.27 11 AV6 +0.00 0.23 10 AV7 +0.02 79 84 0.29 12 AV3 +0.00 0.16 8 AV4 +0.03 79 86 0.24 10 AV3 +0.00 0.17 8 AV4 -0.02 0.14 7 AV5 +0.19 0.20 9 AV6 +0.00 0.17 8 AV7 +0.00 79 88 0.19 9 AV3 +0.00 0.18 8 AV5 +0.02 0.14 7 AV2 +0.02 79 92 0.13 7 AV7 +0.14 79 94 0.14 7 AV2 +0.05 0.13 7 AV3 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 63 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 8 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.15 7 AV4 +0.05 0.10 6 AV6 +0.19 79 96 0.16 8 AV1 +0.00 0.29 12 AV2 +0.00 0.20 9 AV3 +0.05 0.07 4 AV4 -0.14 0.34 13 AV6 +0.05 0.39 14 AV7 +0.05 79 98 0.36 14 AV4 +0.00 0.30 12 AV5 +0.00 0.18 9 AV7 +0.05 79 100 0.12 6 AV3 +0.00 0.24 10 AV4 +0.03 0.27 11 AV5 +0.00 79 104 0.10 5 AV2 +0.02 0.24 10 AV3 +0.07 0.53 17 AV4 +0.08 0.43 15 AV5 +0.05 0.12 6 AV6 +0.02 0.16 8 AV7 +0.00 79 106 0.28 12 AV2 +0.00 0.27 11 AV3 +0.02 0.19 9 AV4 +0.05 79 108 0.14 7 AV4 +0.03 0.18 8 AV5 +0.00 0.28 12 AV6 +0.00 79 110 0.41 15 AV4 +0.03 0.11 6 AV8 +0.02 79 128 0.10 6 AV4 -0.05 79 132 0.23 10 AV6 +0.00 0.41 15 AV7 +0.02 79 136 0.12 6 AV4 +0.03 79 150 0.13 7 AV1 -0.17 0.13 7 AV8 +0.19 79 152 0.10 6 AV1 +0.14 0.14 7 AV2 +0.07 0.13 7 AV4 +0.05 0.25 11 AV7 +0.00 80 19 0.14 7 AV1 +0.00 0.11 6 AV2 +0.02 0.13 7 AV3 +0.02 0.15 7 AV6 +0.02 0.09 5 AV7 +0.09 0.22 10 AV8 +0.02 80 21 0.21 9 AV1 -0.02 0.37 14 AV2 +0.05 0.12 6 AV3 +0.19 0.21 10 AV4 +0.08 80 23 0.10 6 AV4 +0.22 0.11 6 AV6 +0.02 80 25 0.13 7 AV4 +0.00 80 27 0.12 6 AV1 -0.17 80 29 0.10 5 AV4 +0.16 80 35 0.17 8 AV4 +0.22 0.21 10 AV7 -0.02 80 37 0.20 9 AV5 -0.03 80 51 0.19 9 AV7 +0.05 80 59 0.19 9 AV1 +0.05 0.30 12 AV4 -0.21 0.15 8 AV7 +0.05 80 63 0.14 7 AV2 +0.00 0.17 8 AV4 -0.12 0.32 13 AV6 +0.05 0.15 7 AV7 +0.02 80 65 0.42 15 AV2 +0.02 0.28 12 AV3 +0.02 0.42 15 AV4 +0.05 0.57 18 AV5 +0.02 0.59 19 AV6 +0.02 0.20 9 AV7 +0.02 80 67 0.13 7 AV2 -0.02 80 69 0.24 10 AV2 +0.00 0.12 6 AV4 -0.14 0.17 8 AV5 +0.00 80 71 0.13 7 AV3 +0.05 0.23 10 AV4 +0.05 0.45 16 AV5 +0.02 0.50 17 AV6 +0.02 80 73 0.12 6 AV4 +0.03 0.11 6 AV7 +0.07 80 75 0.12 6 AV3 -0.02 0.23 10 AV4 +0.03 0.53 17 AV6 +0.02 0.18 8 AV7 +0.02 80 77 0.34 13 AV7 +0.05 0.18 9 AV3 +0.02 0.46 16 AV4 +0.03 80 79 0.15 8 AV3 -0.02 80 81 0.15 8 AV3 +0.00 0.15 8 AV5 +0.07 80 83 0.19 9 AV3 +0.02 0.28 12 AV4 +0.03 0.18 8 AV5 +0.00 80 85 0.23 10 AV3 +0.00 0.18 8 AV4 +0.08 0.11 6 AV6 -0.02 0.17 8 AV7 +0.00 80 87 0.24 10 AV2 +0.05 0.25 11 AV3 -0.14 0.19 9 AV4 +0.00 0.50 17 AV5 +0.00 0.28 12 AV6 +0.02 0.13 7 AV7 +0.00 80 89 0.15 8 AV3 -0.02 0.11 6 AV7 +0.02 0.14 7 AV2 -0.19 80 91 0.17 8 AV3 -0.02 0.12 6 AV4 +0.03 80 93 0.15 8 AV3 +0.00 0.21 9 AV6 +0.00 0.21 10 AV7 +0.02 80 95 0.10 6 AV2 -0.14 0.10 5 AV4 +0.03 0.19 9 AV5 +0.02 80 97 0.14 7 AV3 +0.00 0.11 6 AV4 +0.03 0.14 7 AV5 +0.02 0.16 8 AV6 +0.00 0.14 7 AV2 +0.02 80 99 0.14 7 AV2 -0.02 0.23 10 AV4 +0.00 0.27 11 AV5 +0.00 0.18 8 AV6 -0.02 80 101 0.18 8 AV4 +0.03 0.29 12 AV5 +0.02 0.24 10 AV6 +0.02 80 103 0.10 6 AV6 -0.02 80 105 0.26 11 AV4 +0.22 0.07 4 AV5 +0.05 0.13 7 AV6 +0.03 80 109 0.14 7 AV6 +0.00 0.10 6 AV4 -0.19 80 115 0.15 7 AV5 -0.17 80 125 0.14 7 AV5 -0.03 80 135 0.14 7 AV3 -0.02 0.14 7 AV5 -0.03 80 139 0.14 7 AV3 +0.02 80 143 0.18 9 AV2 +0.00 0.19 9 AV3 +0.00 80 145 0.18 8 AV4 +0.00 80 151 0.15 8 AV1 -0.12 0.13 7 AV2 +0.02 0.27 11 AV6 -0.02 81 20 0.17 8 AV6 -0.02 81 22 0.17 8 AV1 -0.14 0.16 8 AV3 +0.00 0.13 7 AV5 +0.17 0.18 8 AV6 +0.07 81 26 0.12 6 AV2 +0.02 0.14 7 AV5 +0.19 81 28 0.18 9 AV1 +0.02 0.17 8 AV4 +0.00 0.10 6 AV5 +0.19 81 30 0.13 7 AV4 +0.25 81 36 0.17 8 AV4 +0.00 0.22 10 AV7 +0.02 81 38 0.15 7 AV2 +0.00 0.16 8 AV4 +0.08 81 44 0.27 11 AV6 +0.02 81 52 0.11 6 AV3 +0.02 0.12 6 AV4 +0.08 0.26 11 AV5 +0.05 0.16 8 AV6 +0.12 81 54 0.23 10 AV4 +0.05 0.61 19 AV5 +0.00 0.18 8 AV7 +0.02 81 56 0.14 7 AV3 +0.05 0.23 10 AV5 +0.05 81 62 0.18 8 AV6 +0.05 0.15 8 AV7 +0.07 81 64 0.34 13 AV3 +0.05 0.16 8 AV4 +0.05 0.41 15 AV5 +0.02 0.27 11 AV7 +0.05 81 66 0.40 15 AV3 +0.02 81 68 0.18 8 AV1 +0.00 0.17 8 AV2 +0.02 0.17 8 AV4 +0.00 0.57 18 AV5 +0.02 0.47 16 AV6 +0.00 81 70 0.19 9 AV4 +0.00 0.53 18 AV5 +0.02 0.61 19 AV6 +0.02 0.20 9 AV7 +0.00 81 72 0.15 8 AV4 +0.00 0.28 12 AV5 +0.02 81 74 0.23 10 AV2 -0.02 0.21 10 AV3 +0.00 0.27 11 AV4 +0.03 0.15 8 AV5 +0.00 81 76 0.32 13 AV4 +0.00 0.30 12 AV5 +0.00 0.19 9 AV6 +0.05 0.35 13 AV7 +0.02 81 78 0.26 11 AV4 +0.03 0.38 14 AV5 +0.00 0.45 16 AV6 +0.02 0.48 17 AV7 +0.02 81 80 0.19 9 AV7 +0.00 0.17 8 AV2 +0.02 0.17 8 AV3 +0.02 0.58 18 AV4 +0.05 0.47 16 AV5 +0.02 0.33 13 AV6 +0.02 81 82 0.48 16 AV3 +0.02 0.34 13 AV4 +0.05 0.48 16 AV5 +0.05 0.56 18 AV6 +0.00 0.22 10 AV7 +0.02 81 84 0.29 12 AV3 +0.02 0.27 11 AV4 +0.00 0.19 9 AV5 +0.00 0.13 7 AV6 +0.02 81 86 0.22 10 AV3 -0.02 0.49 17 AV4 +0.05 0.37 14 AV5 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 64 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 9 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.19 9 AV6 +0.00 81 88 0.19 9 AV2 +0.02 0.23 10 AV3 +0.02 0.18 9 AV5 +0.02 81 90 0.16 8 AV5 +0.00 0.18 8 AV6 +0.02 0.19 9 AV7 +0.02 81 92 0.23 10 AV2 +0.00 0.16 8 AV3 +0.07 0.33 13 AV4 +0.03 0.32 13 AV5 +0.02 0.17 8 AV6 -0.05 81 94 0.14 7 AV4 +0.03 0.13 7 AV5 +0.07 81 96 0.18 8 AV4 +0.00 0.16 8 AV5 +0.02 0.28 12 AV6 +0.02 0.47 16 AV7 +0.00 0.17 8 AV8 +0.00 81 98 0.28 11 AV1 +0.00 0.19 9 AV2 +0.00 0.14 7 AV3 +0.02 0.20 9 AV4 +0.08 0.20 9 AV5 +0.05 81 100 0.20 9 AV5 +0.00 81 104 0.17 8 AV5 +0.00 81 106 0.23 10 AV2 +0.00 0.32 13 AV3 +0.02 0.31 13 AV4 +0.05 81 108 0.16 8 AV6 +0.05 81 124 0.18 8 AV6 +0.00 81 150 0.17 8 AV1 -0.14 82 19 0.09 5 AV3 -0.12 82 21 0.14 7 AV1 +0.00 0.18 9 AV3 +0.02 0.14 7 AV4 +0.05 0.10 5 AV5 +0.02 82 23 0.20 9 AV1 +0.00 0.18 8 AV3 +0.05 0.14 7 AV4 +0.19 82 25 0.13 7 AV1 +0.02 0.19 9 AV4 +0.03 82 27 0.15 7 AV4 +0.03 82 31 0.13 7 AV5 -0.03 82 33 0.19 9 AV4 +0.14 82 41 0.18 9 AV3 +0.02 82 43 0.13 7 AV4 +0.03 82 57 0.17 8 AV6 +0.07 82 59 0.22 10 AV3 +0.02 0.13 7 AV7 +0.02 82 61 0.26 11 AV5 +0.02 0.16 8 AV6 +0.02 82 65 0.16 8 AV1 +0.02 0.16 8 AV2 +0.00 0.25 11 AV5 +0.00 0.40 15 AV6 +0.02 0.29 12 AV7 +0.00 82 67 0.17 8 AV5 +0.02 0.20 9 AV6 +0.02 82 69 0.12 6 AV4 +0.05 82 71 0.29 12 AV2 +0.02 0.24 10 AV6 +0.02 82 73 0.23 10 AV2 -0.05 0.21 9 AV6 +0.07 0.19 9 AV7 +0.05 82 75 0.35 13 AV7 -0.02 0.46 16 AV4 +0.03 0.20 9 AV3 +0.05 82 77 0.37 14 AV4 +0.03 0.37 14 AV5 +0.02 0.60 19 AV6 +0.00 0.30 12 AV7 +0.00 82 79 0.13 7 AV3 -0.12 82 81 0.15 7 AV1 -0.05 0.16 8 AV2 -0.02 0.23 10 AV3 +0.02 0.27 11 AV5 +0.07 82 83 0.25 11 AV3 -0.11 0.28 11 AV5 -0.03 0.38 14 AV6 -0.02 82 85 0.42 15 AV3 +0.05 0.35 14 AV4 +0.05 0.18 8 AV5 +0.00 0.20 9 AV6 -0.02 0.18 8 AV7 +0.05 82 87 0.17 8 AV2 +0.00 0.32 13 AV3 -0.16 0.25 11 AV4 +0.00 0.32 13 AV5 +0.02 0.36 14 AV6 +0.02 0.16 8 AV7 +0.02 82 89 0.15 7 AV2 +0.00 0.17 8 AV3 +0.02 0.14 7 AV4 +0.00 82 91 0.15 7 AV3 -0.16 82 93 0.13 7 AV2 +0.05 0.13 7 AV3 +0.00 0.18 8 AV4 +0.05 0.16 8 AV6 +0.07 0.17 8 AV7 +0.02 82 95 0.15 7 AV1 +0.05 0.25 11 AV2 +0.00 0.28 12 AV3 +0.02 0.18 8 AV4 +0.03 0.13 7 AV5 +0.02 0.21 9 AV6 +0.00 82 97 0.30 12 AV2 +0.02 0.33 13 AV3 +0.00 0.38 14 AV4 +0.00 0.56 18 AV5 +0.02 0.33 13 AV6 -0.02 0.27 11 AV7 +0.02 82 99 0.18 9 AV2 +0.00 0.31 12 AV3 +0.05 0.36 14 AV4 +0.05 0.43 15 AV7 +0.02 0.18 8 AV8 +0.05 82 103 0.17 8 AV4 +0.03 0.24 10 AV7 +0.05 82 105 0.15 8 AV4 +0.05 0.46 16 AV5 +0.00 82 107 0.33 13 AV5 +0.02 0.22 10 AV6 +0.05 82 109 0.13 7 AV3 +0.02 0.23 10 AV4 +0.00 82 145 0.12 6 AV3 -0.11 0.21 9 AV4 +0.05 82 147 0.23 10 AV2 +0.02 82 149 0.24 10 AV2 +0.00 83 20 0.19 9 AV3 +0.07 83 22 0.19 9 AV2 +0.02 83 24 0.09 5 AV2 +0.22 83 26 0.16 8 AV4 +0.03 83 28 0.15 7 AV5 +0.17 83 32 0.20 9 AV1 +0.05 0.24 11 AV2 +0.05 83 36 0.17 8 AV3 +0.00 0.26 11 AV5 +0.02 83 38 0.12 6 AV5 +0.18 83 46 0.11 6 AV4 -0.02 83 52 0.15 7 AV6 +0.02 83 54 0.26 11 AV5 +0.07 0.45 16 AV6 +0.05 0.33 13 AV7 +0.02 83 56 0.26 11 AV6 +0.02 0.25 11 AV7 +0.00 0.14 7 AV5 +0.00 83 58 0.09 5 AV2 +0.02 0.18 9 AV4 +0.05 83 60 0.09 5 AV4 +0.03 83 62 0.63 19 AV5 +0.02 0.44 16 AV6 +0.05 0.43 15 AV7 +0.05 83 64 0.24 10 AV3 +0.00 0.55 18 AV6 +0.00 0.34 13 AV7 +0.05 83 66 0.20 9 AV2 +0.02 0.14 7 AV3 +0.02 0.46 16 AV4 +0.05 83 70 0.15 7 AV4 +0.00 0.39 14 AV5 +0.02 0.62 19 AV6 +0.02 0.15 7 AV7 +0.02 83 72 0.15 7 AV3 +0.02 83 74 0.12 6 AV3 +0.02 0.30 12 AV4 +0.03 0.44 16 AV5 +0.05 0.17 8 AV6 +0.02 83 76 0.11 6 AV4 +0.03 0.37 14 AV5 +0.05 83 78 0.48 17 AV4 +0.08 0.34 13 AV3 +0.05 83 80 0.25 11 AV3 +0.00 0.40 15 AV4 +0.05 0.24 11 AV7 +0.00 83 84 0.39 14 AV3 +0.02 0.16 8 AV4 +0.05 0.49 17 AV5 +0.02 0.32 13 AV7 -0.02 83 86 0.33 13 AV4 +0.00 0.13 7 AV5 +0.05 0.14 7 AV6 -0.02 0.13 7 AV7 +0.02 0.16 8 AV3 +0.00 83 88 0.21 9 AV2 +0.02 0.30 12 AV3 +0.05 0.11 6 AV4 -0.02 0.18 8 AV5 +0.02 0.15 7 AV6 -0.02 83 90 0.15 8 AV2 -0.02 0.13 7 AV3 +0.07 0.19 9 AV4 +0.00 0.19 9 AV5 +0.02 0.17 8 AV6 +0.02 83 92 0.17 8 AV4 +0.00 0.32 13 AV5 +0.00 0.24 10 AV6 -0.05 0.18 8 AV7 +0.05 83 94 0.12 6 AV8 +0.00 0.23 10 AV6 +0.07 0.28 12 AV7 +0.00 0.26 11 AV4 +0.08 0.25 11 AV5 +0.05 83 96 0.11 6 AV2 +0.00 0.15 7 AV3 +0.00 0.11 6 AV4 -0.05 0.28 12 AV5 +0.05 0.23 10 AV6 +0.05 0.54 18 AV7 +0.05 0.28 12 AV8 +0.00 83 98 0.14 7 AV2 -0.02 0.15 7 AV3 +0.02 0.31 12 AV4 +0.03 0.46 16 AV6 +0.05 0.14 7 AV7 +0.00 83 100 0.31 12 AV3 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 65 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 10 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.23 10 AV4 +0.05 0.41 15 AV5 +0.02 0.26 11 AV6 +0.02 83 102 0.29 12 AV5 +0.02 0.21 10 AV6 +0.03 0.32 13 AV7 +0.02 83 104 0.26 11 AV5 +0.05 0.31 12 AV6 +0.02 83 106 0.56 18 AV4 +0.05 0.63 19 AV6 +0.00 0.51 17 AV7 +0.00 83 110 0.27 11 AV5 +0.08 0.26 11 AV6 +0.05 0.27 11 AV8 +0.02 83 128 0.09 5 AV4 -0.12 83 130 0.09 5 AV2 +0.02 83 136 0.12 6 AV3 -0.18 83 140 0.13 7 AV5 -0.16 83 146 0.13 7 AV2 -0.17 84 21 0.24 10 AV3 +0.05 0.14 7 AV6 +0.00 84 23 0.25 11 AV1 +0.02 0.21 10 AV3 +0.05 0.13 7 AV4 +0.06 0.09 5 AV7 -0.12 84 25 0.13 7 AV1 +0.19 0.14 7 AV4 +0.03 84 27 0.11 6 AV1 +0.19 0.22 10 AV4 +0.00 84 29 0.13 7 AV4 +0.06 84 31 0.13 7 AV2 +0.14 84 33 0.12 6 AV4 +0.06 84 57 0.44 16 AV5 +0.05 0.19 9 AV3 +0.02 0.17 8 AV4 -0.02 0.18 8 AV6 +0.00 84 63 0.12 6 AV3 +0.02 0.16 8 AV4 +0.03 0.44 16 AV6 +0.00 84 65 0.15 8 AV5 -0.22 0.36 14 AV6 +0.05 0.36 14 AV7 +0.02 84 67 0.10 6 AV1 +0.00 0.10 6 AV2 +0.00 0.24 10 AV4 +0.05 0.11 6 AV7 -0.12 84 71 0.11 6 AV2 +0.00 0.24 11 AV4 +0.03 84 73 0.12 6 AV1 -0.02 0.36 14 AV2 +0.05 0.52 17 AV3 +0.02 0.44 16 AV6 +0.00 84 75 0.14 7 AV3 +0.00 0.54 18 AV4 +0.05 0.33 13 AV7 -0.02 84 77 0.25 11 AV3 +0.02 0.61 19 AV4 +0.05 84 79 0.11 6 AV5 +0.00 0.21 9 AV6 +0.05 84 81 0.23 10 AV3 -0.02 0.16 8 AV4 +0.03 0.47 16 AV5 +0.02 84 83 0.11 6 AV2 +0.00 0.42 15 AV3 +0.05 0.24 11 AV4 +0.08 0.38 14 AV5 +0.02 0.22 10 AV6 +0.05 84 85 0.12 6 AV2 -0.02 0.34 13 AV3 +0.00 0.28 12 AV4 +0.05 0.33 13 AV5 +0.05 0.17 8 AV7 +0.00 84 87 0.22 10 AV3 +0.02 0.31 12 AV4 +0.03 0.30 12 AV5 +0.02 0.52 17 AV6 +0.02 0.21 9 AV7 +0.02 84 89 0.16 8 AV3 -0.02 0.14 7 AV4 -0.05 0.62 19 AV6 +0.00 0.18 9 AV7 +0.02 84 91 0.17 8 AV5 +0.05 0.26 11 AV6 +0.02 0.22 10 AV7 +0.02 84 93 0.15 7 AV1 -0.02 0.17 8 AV2 +0.00 0.19 9 AV3 +0.00 0.25 11 AV5 +0.02 0.27 11 AV6 +0.02 0.20 9 AV7 +0.05 84 95 0.20 9 AV1 +0.02 0.40 15 AV2 -0.02 0.39 14 AV3 +0.00 0.13 7 AV4 +0.00 0.25 11 AV5 +0.00 0.13 7 AV6 -0.02 0.31 12 AV7 +0.00 84 97 0.22 10 AV2 +0.02 0.15 7 AV3 +0.00 0.18 8 AV4 +0.00 0.15 7 AV6 -0.02 0.25 11 AV7 +0.05 0.08 5 AV8 +0.00 84 99 0.11 6 AV2 +0.00 0.28 12 AV3 +0.02 0.31 12 AV4 +0.03 0.56 18 AV5 +0.02 0.53 18 AV6 +0.00 0.32 13 AV7 +0.00 84 101 0.14 7 AV2 +0.00 0.35 13 AV4 +0.03 0.30 12 AV5 +0.05 0.25 11 AV6 +0.02 84 103 0.17 8 AV2 -0.05 0.14 7 AV4 +0.03 84 105 0.11 6 AV2 +0.07 0.36 14 AV4 +0.08 0.45 16 AV7 +0.00 84 107 0.13 7 AV4 +0.03 0.36 14 AV5 +0.02 84 141 0.13 7 AV5 -0.03 84 143 0.15 7 AV2 +0.00 84 149 0.13 7 AV1 -0.13 0.15 8 AV2 +0.00 0.17 8 AV3 +0.02 85 22 0.21 9 AV7 +0.00 0.10 6 AV8 +0.04 0.16 8 AV2 +0.00 0.16 8 AV6 +0.02 85 24 0.11 6 AV1 +0.02 0.09 5 AV4 +0.08 0.14 7 AV5 +0.05 85 26 0.15 7 AV1 -0.17 0.15 7 AV4 +0.00 0.09 5 AV5 +0.20 85 28 0.14 7 AV4 +0.03 0.19 9 AV5 +0.18 85 30 0.08 5 AV1 +0.00 0.13 7 AV2 +0.02 0.12 6 AV5 +0.00 85 32 0.11 6 AV4 +0.08 85 36 0.11 6 AV4 +0.05 0.12 6 AV5 +0.14 85 44 0.45 16 AV6 +0.02 0.49 17 AV5 +0.00 85 56 0.17 8 AV2 +0.00 85 60 0.18 8 AV7 +0.02 85 62 0.23 10 AV5 +0.02 85 64 0.38 14 AV5 +0.02 0.27 11 AV6 +0.02 0.19 9 AV7 +0.02 85 66 0.16 8 AV4 +0.08 0.29 12 AV5 +0.02 0.22 10 AV6 +0.05 0.14 7 AV7 +0.05 85 68 0.17 8 AV5 +0.07 85 70 0.14 7 AV3 +0.05 0.07 5 AV4 -0.07 0.27 11 AV5 +0.16 0.17 8 AV6 +0.02 85 72 0.10 5 AV4 +0.03 0.27 11 AV7 +0.05 85 74 0.35 13 AV3 +0.02 0.12 6 AV4 +0.05 0.12 6 AV5 +0.00 0.21 9 AV6 -0.14 85 76 0.52 17 AV7 +0.00 0.32 13 AV3 +0.00 0.26 11 AV4 +0.00 85 78 0.16 8 AV3 +0.02 0.22 10 AV4 +0.08 0.57 18 AV5 +0.02 0.63 19 AV6 +0.05 0.58 18 AV7 +0.02 85 80 0.09 5 AV5 -0.03 0.14 7 AV7 +0.02 85 82 0.20 9 AV6 +0.00 85 84 0.11 6 AV6 +0.02 85 86 0.12 6 AV3 -0.02 0.14 7 AV4 -0.02 0.21 9 AV5 +0.05 0.19 9 AV6 -0.05 85 88 0.14 7 AV3 +0.00 85 90 0.11 6 AV3 -0.12 0.10 6 AV5 +0.21 85 92 0.31 12 AV2 +0.05 0.21 9 AV3 +0.07 0.28 12 AV4 +0.00 0.15 7 AV5 +0.05 0.25 11 AV6 +0.10 0.23 10 AV7 +0.02 85 94 0.09 5 AV2 +0.00 0.09 5 AV4 -0.02 0.14 7 AV5 +0.00 0.11 6 AV6 +0.02 0.08 5 AV7 -0.02 85 96 0.09 5 AV1 -0.02 0.18 8 AV2 +0.02 0.10 6 AV3 +0.00 0.15 8 AV4 +0.00 0.18 9 AV5 +0.02 0.15 7 AV6 +0.00 85 98 0.19 9 AV2 +0.02 0.16 8 AV3 -0.02 0.37 14 AV4 +0.05 0.28 12 AV7 +0.02 85 100 0.16 8 AV3 -0.02 0.60 19 AV4 +0.03 0.28 12 AV6 +0.02 85 102 0.14 7 AV3 +0.00 0.15 7 AV4 -0.14 85 104 0.51 17 AV3 +0.00 0.57 18 AV4 +0.03 0.33 13 AV5 +0.00 0.14 7 AV6 +0.00 85 106 0.20 9 AV2 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 66 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 11 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.24 10 AV3 +0.05 0.25 11 AV4 +0.03 85 108 0.18 8 AV3 +0.02 85 110 0.13 7 AV4 +0.03 0.18 8 AV5 +0.05 86 23 0.27 11 AV1 +0.02 0.29 12 AV2 +0.00 0.21 9 AV5 +0.00 0.16 8 AV6 +0.00 0.17 8 AV7 -0.14 86 25 0.09 5 AV1 +0.23 0.11 6 AV2 -0.18 0.15 7 AV4 +0.00 86 27 0.16 8 AV4 +0.03 0.19 9 AV6 -0.05 86 43 0.09 5 AV6 +0.02 86 53 0.14 7 AV7 +0.02 86 57 0.17 8 AV5 +0.02 0.22 10 AV8 +0.02 86 59 0.23 10 AV6 +0.02 0.21 10 AV7 -0.02 86 61 0.23 10 AV3 +0.05 86 63 0.13 7 AV4 +0.00 0.23 10 AV5 +0.05 86 65 0.14 7 AV2 +0.00 0.14 7 AV3 +0.00 0.10 6 AV4 -0.14 0.25 11 AV5 +0.02 0.14 7 AV6 +0.00 0.20 9 AV7 +0.00 86 67 0.13 7 AV2 +0.00 0.51 17 AV3 +0.05 0.21 9 AV4 +0.05 86 71 0.20 9 AV3 +0.02 86 73 0.14 7 AV1 -0.02 0.11 6 AV3 +0.02 0.33 13 AV4 +0.05 0.28 12 AV6 +0.02 0.12 6 AV7 +0.12 0.10 6 AV8 +0.05 86 75 0.38 14 AV4 +0.08 0.59 19 AV7 +0.05 86 77 0.12 6 AV3 -0.02 0.23 10 AV5 +0.07 0.15 7 AV7 +0.02 86 79 0.23 10 AV3 +0.05 0.15 7 AV6 +0.05 0.12 6 AV7 +0.00 86 81 0.20 9 AV2 +0.02 0.11 6 AV4 +0.08 0.55 18 AV5 +0.02 86 83 0.19 9 AV3 +0.00 0.35 14 AV4 +0.05 0.46 16 AV5 +0.00 0.35 13 AV6 +0.00 0.40 15 AV7 +0.02 86 85 0.54 18 AV2 +0.00 0.56 18 AV5 +0.07 0.18 8 AV6 +0.02 0.26 11 AV7 +0.02 86 87 0.33 13 AV4 +0.00 0.42 15 AV5 +0.00 0.57 18 AV6 +0.02 0.48 16 AV7 +0.00 0.14 7 AV8 +0.02 0.11 6 AV2 +0.02 0.44 16 AV3 +0.02 86 89 0.13 7 AV2 -0.02 0.19 9 AV3 +0.00 0.45 16 AV4 +0.03 0.45 16 AV5 +0.02 0.32 13 AV7 +0.05 86 91 0.23 10 AV7 +0.02 0.14 7 AV8 +0.02 86 93 0.23 10 AV2 +0.02 0.23 10 AV3 +0.00 0.18 9 AV4 +0.00 0.45 16 AV6 +0.00 0.28 12 AV7 +0.05 0.10 5 AV8 +0.02 86 95 0.28 12 AV3 +0.02 0.25 11 AV4 +0.03 0.46 16 AV5 +0.02 0.43 15 AV6 +0.00 0.43 15 AV7 +0.02 86 97 0.12 6 AV1 -0.02 0.31 12 AV2 +0.02 0.62 19 AV4 +0.05 0.45 16 AV6 +0.02 0.22 10 AV7 +0.02 86 99 0.18 8 AV1 +0.02 0.20 9 AV2 +0.02 0.36 14 AV3 +0.02 0.33 13 AV4 +0.03 0.49 17 AV6 +0.02 0.16 8 AV7 +0.05 86 101 0.11 6 AV3 +0.00 0.23 10 AV4 +0.00 0.12 6 AV5 +0.02 86 103 0.20 9 AV4 +0.00 0.47 16 AV5 +0.02 0.31 12 AV6 +0.05 86 105 0.16 8 AV4 +0.03 0.21 10 AV6 +0.03 86 107 0.12 6 AV4 +0.00 86 109 0.18 9 AV2 +0.00 0.16 8 AV7 -0.02 86 133 0.14 7 AV4 -0.05 87 24 0.12 6 AV7 -0.02 87 34 0.12 6 AV2 +0.00 0.16 8 AV4 +0.00 87 36 0.12 6 AV4 +0.05 87 48 0.15 7 AV5 +0.05 87 54 0.24 10 AV2 -0.02 87 58 0.11 6 AV6 +0.05 87 62 0.16 8 AV2 +0.00 0.22 10 AV6 +0.05 87 64 0.26 11 AV4 +0.00 0.40 15 AV5 +0.02 87 66 0.36 14 AV5 +0.00 0.37 14 AV6 +0.02 0.57 18 AV7 +0.02 0.17 8 AV4 +0.03 87 68 0.29 12 AV2 +0.02 87 70 0.13 7 AV1 +0.00 0.31 12 AV2 -0.02 0.51 17 AV3 +0.02 87 72 0.42 15 AV2 +0.02 0.14 7 AV3 +0.00 0.37 14 AV4 +0.03 0.19 9 AV5 +0.02 0.17 8 AV7 +0.05 87 74 0.19 9 AV3 +0.00 0.24 10 AV4 -0.02 0.40 15 AV5 +0.00 0.19 9 AV6 +0.02 87 76 0.32 13 AV3 +0.02 87 78 0.25 11 AV3 +0.02 0.30 12 AV4 +0.00 0.38 14 AV5 +0.00 0.40 15 AV6 +0.02 0.21 10 AV7 +0.02 87 80 0.16 8 AV2 +0.02 0.31 12 AV3 +0.02 0.52 17 AV4 +0.00 0.20 9 AV7 -0.05 87 82 0.18 9 AV2 +0.02 0.30 12 AV3 +0.05 0.49 17 AV4 +0.08 87 84 0.16 8 AV1 +0.02 0.36 14 AV2 +0.02 0.61 19 AV3 +0.05 0.21 9 AV6 +0.05 87 86 0.34 13 AV3 +0.02 0.25 11 AV4 +0.05 0.36 14 AV5 +0.02 0.22 10 AV6 +0.02 0.16 8 AV7 +0.02 87 88 0.18 8 AV2 +0.00 0.28 12 AV3 +0.00 0.20 9 AV4 +0.03 0.40 15 AV5 +0.02 0.16 8 AV6 +0.05 87 90 0.16 8 AV2 +0.00 0.21 10 AV3 +0.05 0.45 16 AV4 +0.00 0.47 16 AV6 +0.00 0.35 14 AV7 +0.02 87 92 0.20 9 AV3 +0.05 0.30 12 AV4 +0.00 0.46 16 AV5 +0.02 0.17 8 AV7 -0.02 87 94 0.19 9 AV2 +0.02 0.17 8 AV3 +0.05 0.19 9 AV4 +0.05 0.23 10 AV5 +0.05 0.22 10 AV6 +0.00 87 96 0.20 9 AV1 +0.00 0.39 14 AV2 +0.05 0.40 15 AV3 +0.05 0.31 12 AV4 +0.05 0.37 14 AV6 +0.05 0.14 7 AV7 +0.05 87 98 0.32 13 AV2 +0.00 0.25 11 AV4 +0.03 0.58 18 AV5 +0.00 87 100 0.18 8 AV4 +0.03 0.18 8 AV5 +0.02 0.23 10 AV6 +0.02 0.15 7 AV7 +0.07 87 102 0.46 16 AV2 +0.02 0.45 16 AV3 +0.05 87 104 0.16 8 AV3 +0.07 87 106 0.20 9 AV6 +0.03 0.24 10 AV8 +0.00 87 110 0.22 10 AV4 +0.05 0.50 17 AV5 +0.02 0.30 12 AV6 +0.00 0.33 13 AV7 +0.02 87 120 0.13 7 AV5 +0.02 87 122 0.13 7 AV4 -0.02 87 128 0.10 6 AV3 +0.07 87 130 0.17 8 AV4 +0.05 88 23 0.12 6 AV1 +0.02 0.16 8 AV4 +0.03 88 27 0.13 7 AV1 +0.02 0.16 8 AV4 +0.03 88 29 0.21 9 AV1 +0.18 88 37 0.11 6 AV5 +0.00 88 39 0.16 8 AV3 -0.02 0.19 9 AV4 +0.03 88 41 0.14 7 AV4 -0.02 88 47 0.12 6 AV4 -0.17 88 49 0.11 6 AV5 +0.16 88 59 0.18 8 AV3 +0.00 0.20 9 AV4 +0.08 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 67 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 12 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.22 10 AV5 +0.00 0.58 18 AV6 +0.02 0.24 10 AV7 +0.05 88 63 0.18 8 AV5 +0.00 88 65 0.22 10 AV2 +0.02 0.26 11 AV5 +0.05 88 67 0.17 8 AV3 +0.02 88 69 0.15 7 AV4 +0.05 0.14 7 AV5 -0.16 88 71 0.38 14 AV3 +0.05 0.23 10 AV8 +0.00 88 73 0.57 18 AV4 +0.00 0.45 16 AV5 +0.02 0.52 17 AV6 +0.00 0.17 8 AV3 +0.02 88 75 0.23 10 AV2 +0.05 0.19 9 AV3 -0.02 0.22 10 AV5 +0.00 0.16 8 AV6 +0.05 88 77 0.18 8 AV5 +0.00 0.24 10 AV6 +0.02 0.29 12 AV7 -0.02 88 79 0.19 9 AV4 +0.05 0.16 8 AV7 +0.02 88 81 0.17 8 AV2 +0.00 0.16 8 AV3 +0.02 0.20 9 AV4 +0.00 0.29 12 AV6 +0.00 0.39 15 AV7 +0.00 88 83 0.22 10 AV3 +0.02 0.17 8 AV5 +0.00 0.16 8 AV6 +0.02 88 85 0.52 17 AV2 +0.02 0.56 18 AV3 +0.05 0.63 19 AV4 +0.05 0.31 13 AV6 +0.02 88 87 0.26 11 AV3 +0.02 0.23 10 AV4 +0.08 0.20 9 AV5 +0.05 0.58 18 AV6 +0.02 0.57 18 AV7 +0.02 0.22 10 AV8 +0.02 88 89 0.26 11 AV3 +0.00 0.21 9 AV4 +0.05 88 91 0.15 7 AV2 +0.02 0.16 8 AV6 +0.02 88 93 0.18 9 AV2 +0.00 0.17 8 AV3 +0.02 0.18 9 AV4 +0.03 0.26 11 AV6 +0.02 0.28 12 AV7 +0.05 88 95 0.35 13 AV3 +0.00 0.52 17 AV4 +0.03 0.40 15 AV8 +0.00 0.15 7 AV2 +0.02 88 97 0.62 19 AV4 +0.05 0.41 15 AV7 +0.02 0.40 15 AV2 +0.02 88 99 0.21 9 AV1 +0.02 0.24 10 AV2 +0.00 0.49 17 AV3 +0.05 0.60 19 AV7 +0.02 88 101 0.17 8 AV3 +0.02 88 103 0.13 7 AV2 +0.00 0.51 17 AV4 +0.00 0.54 18 AV7 +0.02 88 105 0.35 14 AV2 +0.00 0.24 10 AV3 +0.02 0.27 11 AV6 +0.02 88 107 0.21 9 AV3 +0.02 0.19 9 AV4 +0.03 0.41 15 AV5 +0.00 0.26 11 AV6 +0.02 0.17 8 AV7 +0.02 88 111 0.19 9 AV3 +0.00 0.19 9 AV6 +0.05 88 113 0.16 8 AV5 +0.05 88 131 0.16 8 AV3 +0.05 0.09 5 AV5 +0.05 88 133 0.20 9 AV2 +0.00 89 26 0.08 5 AV1 -0.13 89 36 0.13 7 AV4 +0.03 89 38 0.08 5 AV4 -0.02 89 40 0.15 8 AV4 +0.05 89 42 0.14 7 AV6 +0.02 89 46 0.11 6 AV3 +0.00 89 48 0.15 8 AV5 +0.05 89 52 0.09 5 AV2 +0.00 89 58 0.14 7 AV2 +0.02 0.11 6 AV3 -0.02 89 60 0.19 9 AV3 +0.00 0.09 5 AV7 -0.02 89 62 0.18 9 AV2 +0.00 0.37 14 AV3 +0.00 0.17 8 AV4 +0.03 89 64 0.15 7 AV5 +0.05 89 66 0.32 13 AV4 +0.05 0.14 7 AV5 +0.05 0.23 10 AV7 +0.07 89 68 0.17 8 AV3 +0.00 0.16 8 AV4 +0.00 0.29 12 AV5 +0.00 89 70 0.35 13 AV5 +0.00 89 72 0.11 6 AV1 +0.00 0.12 6 AV2 +0.00 0.25 11 AV3 +0.05 0.13 7 AV4 +0.03 0.42 15 AV6 +0.05 0.22 10 AV8 +0.09 89 74 0.22 10 AV2 +0.02 0.37 14 AV3 +0.02 0.44 16 AV4 +0.05 0.51 17 AV5 +0.05 89 76 0.10 6 AV3 +0.00 0.16 8 AV4 +0.00 0.26 11 AV5 +0.00 0.17 8 AV6 +0.02 0.21 10 AV7 +0.05 89 78 0.25 11 AV5 +0.00 0.20 9 AV7 +0.02 89 80 0.17 8 AV2 +0.02 0.35 13 AV3 +0.00 0.19 9 AV4 +0.00 0.33 13 AV5 +0.00 0.20 9 AV6 +0.07 89 82 0.15 8 AV2 +0.02 0.53 18 AV4 +0.03 0.47 16 AV7 +0.05 89 84 0.09 5 AV1 +0.00 0.31 13 AV2 +0.02 0.25 11 AV3 +0.00 0.20 9 AV7 +0.00 89 86 0.24 10 AV2 +0.00 0.50 17 AV3 -0.02 0.44 16 AV4 +0.00 0.60 19 AV5 +0.00 0.28 11 AV6 -0.02 0.22 10 AV7 +0.02 89 88 0.16 8 AV2 +0.00 0.24 10 AV3 +0.00 0.10 6 AV4 +0.03 0.29 12 AV5 +0.00 0.37 14 AV6 +0.02 0.44 16 AV7 +0.00 0.22 10 AV8 +0.05 89 90 0.21 9 AV2 +0.05 0.42 15 AV3 +0.02 0.45 16 AV6 +0.02 0.17 8 AV7 +0.00 89 92 0.12 6 AV2 +0.02 0.15 8 AV3 +0.02 0.57 18 AV5 +0.02 0.18 8 AV6 +0.02 0.34 13 AV7 +0.02 89 94 0.14 7 AV2 +0.02 0.28 12 AV3 +0.02 0.15 8 AV4 +0.05 0.24 10 AV6 +0.02 0.27 11 AV7 +0.02 89 96 0.18 8 AV1 +0.02 0.25 11 AV2 +0.02 0.22 10 AV3 +0.02 0.16 8 AV4 +0.00 0.18 8 AV5 +0.02 0.17 8 AV7 +0.02 89 98 0.15 7 AV7 +0.02 0.18 9 AV1 +0.00 0.19 9 AV3 +0.05 0.50 17 AV4 +0.03 0.17 8 AV5 +0.02 0.10 6 AV6 +0.00 89 100 0.12 6 AV3 -0.02 0.19 9 AV4 +0.08 0.27 11 AV6 +0.02 0.44 16 AV7 +0.05 0.19 9 AV8 +0.05 89 104 0.30 12 AV3 +0.00 0.12 6 AV4 +0.00 89 116 0.15 7 AV5 +0.00 89 128 0.12 6 AV3 +0.05 0.07 4 AV4 -0.16 90 29 0.14 7 AV1 +0.18 90 31 0.13 7 AV1 +0.02 90 33 0.15 7 AV3 +0.00 90 37 0.13 7 AV5 +0.00 90 39 0.08 5 AV5 +0.02 90 43 0.10 6 AV3 -0.02 90 51 0.20 9 AV3 -0.02 90 53 0.17 8 AV8 +0.02 0.11 6 AV3 -0.05 0.28 12 AV5 -0.03 0.18 8 AV6 +0.00 0.35 13 AV7 +0.00 90 59 0.14 7 AV3 +0.00 90 61 0.17 8 AV3 +0.00 0.42 15 AV5 +0.07 90 63 0.51 17 AV5 +0.09 0.30 12 AV6 +0.05 0.21 9 AV7 +0.07 90 65 0.28 12 AV2 +0.05 0.31 12 AV3 +0.00 0.30 12 AV5 +0.05 0.17 8 AV7 +0.02 90 67 0.10 6 AV2 +0.05 0.11 6 AV3 +0.05 0.10 6 AV4 +0.05 0.12 6 AV5 +0.05 0.27 11 AV6 +0.05 0.19 9 AV7 +0.02 90 69 0.11 6 AV3 +0.05 0.19 9 AV4 +0.03 0.17 8 AV5 -0.18 0.22 10 AV6 +0.02 90 71 0.10 6 AV2 -0.02 0.15 8 AV6 +0.05 0.54 18 AV7 +0.05 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 68 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 13 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 90 73 0.19 9 AV3 +0.02 0.37 14 AV4 +0.03 90 75 0.12 6 AV2 -0.02 0.16 8 AV3 -0.19 0.10 6 AV4 +0.03 0.15 7 AV5 -0.03 90 77 0.32 13 AV4 +0.05 90 79 0.30 12 AV4 +0.03 0.42 15 AV6 +0.02 0.26 11 AV7 -0.02 90 81 0.40 15 AV2 +0.00 0.16 8 AV3 +0.00 0.36 14 AV4 +0.03 90 83 0.17 8 AV2 +0.00 0.26 11 AV3 +0.05 0.42 15 AV6 +0.02 90 87 0.29 12 AV3 +0.00 0.45 16 AV4 +0.00 0.23 10 AV5 +0.00 0.21 9 AV6 +0.05 0.29 12 AV7 +0.02 90 89 0.20 9 AV2 +0.02 0.26 11 AV3 +0.05 0.17 8 AV4 +0.03 0.52 17 AV5 +0.05 0.61 19 AV6 +0.02 0.29 12 AV7 +0.05 90 91 0.19 9 AV2 +0.00 0.14 7 AV3 +0.00 0.22 10 AV4 +0.08 0.19 9 AV5 +0.02 90 93 0.22 10 AV2 +0.00 0.16 8 AV3 -0.02 0.19 9 AV4 +0.03 0.26 11 AV5 +0.00 0.23 10 AV6 +0.00 0.40 15 AV7 +0.02 90 95 0.15 8 AV3 +0.00 0.13 7 AV2 -0.14 0.18 8 AV7 +0.02 0.14 7 AV4 +0.00 0.41 15 AV5 +0.02 0.37 14 AV6 +0.02 90 97 0.38 14 AV2 +0.02 0.46 16 AV3 +0.00 0.28 11 AV4 +0.03 0.46 16 AV5 +0.07 90 99 0.14 7 AV2 +0.02 0.21 9 AV3 -0.02 0.11 6 AV4 +0.00 0.63 19 AV5 +0.02 0.33 13 AV7 +0.05 90 101 0.16 8 AV3 +0.00 0.21 10 AV4 +0.08 90 103 0.12 6 AV1 +0.02 0.20 9 AV2 -0.02 0.13 7 AV3 +0.05 0.48 17 AV4 +0.03 0.16 8 AV5 +0.05 0.63 19 AV7 +0.05 0.17 8 AV8 +0.00 90 105 0.15 7 AV5 +0.00 90 107 0.41 15 AV5 +0.05 90 127 0.09 5 AV5 +0.07 90 131 0.15 8 AV5 +0.02 91 24 0.11 6 AV1 -0.14 91 36 0.06 4 AV4 +0.13 91 38 0.09 5 AV5 +0.16 0.08 5 AV3 +0.24 91 44 0.07 4 AV3 -0.19 91 46 0.09 5 AV5 +0.33 0.11 6 AV4 -0.14 91 50 0.17 8 AV6 +0.21 0.12 6 AV5 -0.15 91 54 0.12 6 AV4 +0.15 91 58 0.06 4 AV4 +0.34 91 60 0.15 7 AV4 -0.24 0.26 11 AV2 +0.00 91 62 0.08 5 AV3 +0.26 91 64 0.16 8 AV5 +0.00 91 66 0.29 12 AV7 +0.05 0.08 5 AV2 -0.23 0.12 6 AV1 +0.07 91 68 0.08 5 AV3 -0.19 91 70 0.31 12 AV5 +0.12 0.05 3 AV4 +0.13 91 72 0.08 5 AV6 +0.20 0.20 9 AV5 +0.16 0.14 7 AV4 +0.00 0.10 6 AV2 +0.21 91 74 0.51 17 AV7 +0.00 0.53 18 AV6 -0.02 0.29 12 AV5 -0.05 0.21 9 AV4 -0.02 0.10 5 AV3 +0.00 91 78 0.51 17 AV6 +0.02 0.50 17 AV5 +0.00 0.39 14 AV3 +0.02 0.07 4 AV2 -0.20 91 80 0.29 12 AV7 -0.02 0.44 16 AV5 +0.00 0.11 6 AV4 -0.05 91 82 0.13 7 AV4 -0.09 0.14 7 AV2 -0.02 91 84 0.09 5 AV7 +0.00 0.21 10 AV6 +0.05 0.55 18 AV5 +0.00 0.36 14 AV4 +0.05 0.21 9 AV3 +0.00 0.07 4 AV2 -0.18 91 86 0.22 10 AV7 +0.00 0.28 12 AV6 +0.00 0.47 16 AV5 +0.02 0.47 16 AV4 +0.03 0.38 14 AV2 +0.02 91 88 0.08 5 AV8 +0.44 0.14 7 AV7 -0.02 0.16 8 AV6 +0.00 0.45 16 AV5 -0.03 0.37 14 AV4 +0.03 0.27 11 AV3 +0.00 0.09 5 AV2 +0.00 91 90 0.45 16 AV7 +0.02 0.13 7 AV6 +0.17 0.15 7 AV5 +0.02 0.33 13 AV4 +0.03 0.19 9 AV3 +0.07 91 92 0.62 19 AV8 -0.02 0.51 17 AV4 +0.05 0.16 8 AV3 +0.05 0.17 8 AV2 +0.02 91 94 0.26 11 AV7 -0.02 0.19 9 AV6 +0.02 0.06 4 AV5 -0.08 0.13 7 AV4 -0.05 0.19 9 AV3 +0.00 0.13 7 AV2 -0.05 91 96 0.39 14 AV7 -0.03 0.16 8 AV3 +0.02 0.12 6 AV2 +0.05 0.14 7 AV1 -0.02 91 98 0.24 11 AV4 +0.05 0.39 14 AV3 +0.05 0.18 8 AV2 +0.00 0.21 9 AV1 -0.02 91 100 0.12 6 AV6 +0.02 0.34 13 AV5 +0.02 0.56 18 AV4 +0.05 91 102 0.06 4 AV8 +0.00 0.15 7 AV7 -0.02 0.07 4 AV5 +0.02 91 104 0.20 9 AV3 +0.05 0.09 5 AV6 -0.02 0.07 4 AV5 -0.19 91 106 0.10 5 AV4 -0.19 91 110 0.12 6 AV4 +0.03 0.21 9 AV3 -0.02 91 120 0.12 6 AV5 +0.00 91 124 0.08 5 AV4 -0.19 91 128 0.11 6 AV4 -0.18 91 130 0.09 5 AV4 -0.16 92 25 0.11 6 AV1 -0.05 92 37 0.11 6 AV5 +0.00 92 39 0.20 9 AV5 -0.03 92 43 0.09 5 AV5 +0.09 0.09 5 AV4 +0.29 92 45 0.06 4 AV5 -0.03 92 49 0.14 7 AV4 -0.05 92 53 0.06 4 AV5 -0.03 92 57 0.08 5 AV3 -0.05 92 61 0.15 7 AV3 -0.02 92 63 0.16 8 AV5 +0.05 92 65 0.12 6 AV4 -0.07 92 67 0.11 6 AV4 +0.00 92 69 0.23 10 AV7 +0.00 0.36 14 AV6 -0.03 0.16 8 AV4 -0.02 0.17 8 AV3 +0.00 92 71 0.16 8 AV8 +0.02 0.10 6 AV6 +0.00 0.12 6 AV3 -0.02 0.09 5 AV2 -0.23 92 73 0.09 5 AV7 -0.10 0.10 5 AV4 +0.16 92 75 0.09 5 AV3 -0.19 0.13 7 AV8 +0.00 0.55 18 AV7 +0.00 0.20 9 AV6 +0.05 0.17 8 AV4 +0.03 92 77 0.09 5 AV8 +0.02 0.08 5 AV3 -0.30 0.07 4 AV2 -0.18 92 79 0.29 12 AV7 -0.02 92 81 0.12 6 AV8 +0.00 0.08 5 AV4 +0.36 0.17 8 AV3 -0.16 92 83 0.16 8 AV7 -0.22 0.22 10 AV6 -0.02 0.57 18 AV4 -0.02 0.38 14 AV3 -0.02 0.10 5 AV2 +0.00 92 85 0.46 16 AV4 +0.03 0.18 9 AV3 +0.00 0.25 11 AV2 -0.02 0.06 4 AV1 -0.23 92 87 0.16 8 AV8 +0.05 0.28 11 AV7 +0.02 0.28 12 AV6 +0.00 0.22 10 AV4 +0.00 0.51 17 AV3 +0.05 0.14 7 AV1 +0.00 92 89 0.09 5 AV6 -0.02 0.16 8 AV4 +0.00 0.14 7 AV3 -0.14 0.07 4 AV2 -0.05 92 91 0.21 9 AV7 -0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 69 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 14 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.16 8 AV6 -0.02 0.16 8 AV3 +0.00 92 93 0.23 10 AV7 +0.00 0.32 13 AV6 +0.02 0.28 12 AV4 +0.05 0.12 6 AV3 +0.02 0.11 6 AV2 -0.02 92 95 0.07 4 AV7 +0.02 0.35 14 AV3 +0.02 0.16 8 AV2 -0.16 92 97 0.29 12 AV7 +0.00 0.53 18 AV6 -0.02 0.32 13 AV5 +0.00 0.12 6 AV8 -0.02 0.14 7 AV4 +0.03 0.13 7 AV3 +0.02 0.10 6 AV2 +0.00 92 99 0.36 14 AV8 +0.00 0.61 19 AV7 +0.00 0.25 11 AV4 +0.03 0.56 18 AV3 +0.02 0.53 17 AV2 +0.00 0.36 14 AV1 -0.02 92 101 0.18 9 AV5 +0.02 0.29 12 AV2 +0.00 0.12 6 AV1 +0.12 92 103 0.15 8 AV3 +0.02 0.09 5 AV2 -0.12 92 107 0.09 5 AV7 +0.02 0.20 9 AV4 -0.05 0.18 9 AV3 -0.05 92 109 0.12 6 AV5 +0.02 92 117 0.16 8 AV4 +0.03 92 121 0.14 7 AV5 +0.00 0.11 6 AV3 +0.02 92 123 0.09 5 AV5 +0.16 0.09 5 AV2 +0.00 93 24 0.17 8 AV1 -0.16 93 26 0.16 8 AV1 -0.14 93 30 0.16 8 AV1 +0.14 93 40 0.13 7 AV4 +0.13 0.14 7 AV3 -0.02 93 44 0.14 7 AV4 -0.02 93 46 0.10 6 AV4 +0.18 93 54 0.07 4 AV6 +0.14 93 56 0.09 5 AV3 -0.21 93 60 0.14 7 AV4 -0.19 93 64 0.21 9 AV7 +0.00 0.49 17 AV5 -0.03 0.26 11 AV4 +0.00 93 66 0.14 7 AV6 -0.03 0.18 8 AV5 -0.03 93 68 0.13 7 AV3 -0.05 0.13 7 AV2 -0.02 93 70 0.13 7 AV5 +0.13 0.12 6 AV4 +0.00 93 72 0.09 5 AV7 +0.14 0.43 15 AV6 +0.00 0.19 9 AV4 +0.03 0.12 6 AV3 -0.02 93 74 0.60 19 AV5 +0.00 0.29 12 AV4 +0.03 0.24 10 AV3 +0.00 0.12 6 AV2 -0.02 93 76 0.32 13 AV6 +0.02 93 78 0.15 7 AV7 +0.00 0.40 15 AV6 -0.02 0.61 19 AV5 +0.00 93 80 0.17 8 AV7 +0.00 0.63 19 AV6 +0.02 0.37 14 AV5 -0.03 0.12 6 AV4 +0.00 0.20 9 AV3 -0.02 93 82 0.18 8 AV4 -0.02 0.13 7 AV3 +0.02 0.14 7 AV2 -0.02 93 84 0.17 8 AV8 +0.05 0.47 16 AV7 -0.02 0.36 14 AV3 -0.02 0.20 9 AV2 +0.00 93 86 0.53 17 AV3 +0.00 0.14 7 AV2 +0.00 93 88 0.26 11 AV7 +0.00 0.60 19 AV6 -0.02 0.53 17 AV5 +0.00 0.35 13 AV3 +0.02 0.25 11 AV2 +0.00 93 90 0.12 6 AV7 +0.16 0.31 13 AV5 +0.00 0.12 6 AV4 -0.02 0.14 7 AV3 +0.02 0.15 7 AV2 +0.00 93 92 0.39 14 AV8 +0.00 0.18 9 AV7 -0.24 0.29 12 AV6 -0.02 0.12 6 AV4 -0.16 0.11 6 AV3 -0.05 0.27 11 AV2 +0.00 93 94 0.52 17 AV3 +0.05 0.18 8 AV2 -0.02 0.10 6 AV1 -0.02 93 96 0.14 7 AV4 -0.02 0.13 7 AV3 +0.02 93 98 0.10 5 AV8 -0.02 0.36 14 AV3 -0.02 0.12 6 AV2 -0.05 93 100 0.52 17 AV7 +0.00 0.21 9 AV6 +0.02 0.22 10 AV5 +0.00 0.25 11 AV3 +0.00 0.14 7 AV2 -0.05 93 102 0.27 11 AV5 -0.03 0.18 9 AV4 -0.03 93 104 0.22 10 AV6 +0.00 0.28 12 AV5 +0.00 0.36 14 AV4 +0.03 0.48 16 AV3 +0.05 93 106 0.09 5 AV4 -0.05 93 112 0.13 7 AV4 +0.03 93 116 0.07 4 AV2 -0.19 93 128 0.16 8 AV5 +0.00 0.12 6 AV4 +0.00 93 134 0.10 6 AV8 -0.09 94 25 0.17 8 AV1 -0.16 94 39 0.08 5 AV5 +0.00 94 45 0.18 9 AV4 +0.05 94 47 0.12 6 AV2 +0.14 94 49 0.07 5 AV4 +0.03 94 53 0.11 6 AV6 -0.14 94 55 0.08 5 AV5 -0.03 0.10 6 AV4 -0.19 94 59 0.13 7 AV7 +0.02 0.16 8 AV3 +0.00 94 65 0.17 8 AV6 +0.00 0.10 6 AV5 -0.03 0.10 5 AV2 -0.02 94 67 0.38 14 AV7 +0.02 0.54 18 AV5 +0.00 0.54 18 AV4 -0.02 94 69 0.08 5 AV6 +0.02 0.58 19 AV3 +0.07 0.10 6 AV1 -0.02 94 71 0.51 17 AV5 +0.05 0.08 5 AV3 +0.30 0.07 4 AV2 +0.12 0.09 5 AV1 +0.07 94 73 0.15 7 AV2 +0.05 0.28 12 AV1 -0.05 0.19 9 AV4 +0.16 94 75 0.14 7 AV4 +0.05 0.17 8 AV3 +0.02 94 77 0.59 19 AV7 -0.03 0.27 11 AV4 +0.00 0.15 7 AV2 -0.07 94 79 0.36 14 AV7 -0.03 0.34 13 AV5 +0.02 0.14 7 AV4 -0.02 0.14 7 AV3 -0.05 0.19 9 AV2 -0.02 0.11 6 AV1 -0.02 94 81 0.43 15 AV3 +0.00 94 83 0.22 10 AV8 +0.05 0.57 18 AV7 -0.02 0.23 10 AV2 +0.02 0.11 6 AV1 -0.18 94 85 0.19 9 AV1 +0.00 0.33 13 AV7 +0.00 0.42 15 AV6 -0.02 94 87 0.37 14 AV7 +0.00 0.35 14 AV6 +0.02 0.17 8 AV2 +0.02 94 89 0.11 6 AV8 -0.02 0.09 5 AV7 +0.51 0.16 8 AV6 +0.02 0.21 9 AV5 +0.03 0.38 14 AV4 +0.05 0.42 15 AV3 +0.02 0.24 10 AV2 +0.00 0.07 4 AV1 +0.07 94 91 0.45 16 AV7 +0.02 94 93 0.13 7 AV7 +0.16 0.50 17 AV6 -0.02 0.36 14 AV5 +0.00 0.46 16 AV4 +0.00 0.17 8 AV3 +0.02 0.11 6 AV2 +0.00 0.10 6 AV1 -0.19 94 95 0.35 14 AV5 +0.02 94 97 0.08 5 AV8 +0.00 0.21 9 AV6 +0.00 0.15 8 AV5 -0.03 0.07 4 AV4 -0.05 0.14 7 AV3 +0.00 0.30 12 AV2 +0.00 94 99 0.11 6 AV8 +0.05 0.07 4 AV7 -0.43 0.60 19 AV6 +0.02 0.42 15 AV3 +0.02 0.09 5 AV2 -0.16 0.08 5 AV1 +0.02 94 101 0.19 9 AV4 +0.08 0.13 7 AV3 +0.02 94 103 0.24 10 AV6 -0.02 0.19 9 AV3 +0.02 94 105 0.24 10 AV3 +0.00 0.23 10 AV2 -0.07 94 115 0.08 5 AV4 +0.05 0.13 7 AV3 -0.02 94 119 0.09 5 AV5 +0.00 0.18 9 AV4 +0.00 0.14 7 AV3 +0.02 94 123 0.13 7 AV4 -0.02 94 125 0.36 14 AV2 +0.02 95 28 0.10 6 AV1 -0.18 95 42 0.09 5 AV8 -0.30 95 46 0.13 7 AV4 +0.21 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 70 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 15 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 95 48 0.11 6 AV5 +0.19 95 50 0.13 7 AV5 -0.13 0.10 6 AV4 -0.12 95 54 0.14 7 AV3 +0.00 95 58 0.08 5 AV4 -0.21 0.10 6 AV3 -0.02 95 60 0.12 6 AV4 -0.19 95 62 0.31 13 AV7 +0.02 0.56 18 AV6 +0.00 0.36 14 AV5 -0.03 0.07 4 AV4 -0.02 95 64 0.41 15 AV6 +0.00 0.05 4 AV4 +0.24 0.07 4 AV3 +0.21 95 66 0.11 6 AV5 +0.05 0.59 19 AV4 +0.03 0.13 7 AV3 +0.00 0.07 4 AV2 +0.21 0.07 4 AV1 +0.27 95 68 0.10 6 AV5 -0.13 0.07 4 AV3 -0.14 95 70 0.07 5 AV6 +0.02 0.08 5 AV5 +0.16 0.18 8 AV4 +0.00 0.09 5 AV7 +0.07 95 72 0.19 9 AV6 +0.00 0.50 17 AV5 +0.02 0.35 13 AV4 +0.03 0.46 16 AV3 +0.02 0.12 6 AV1 +0.09 95 74 0.09 5 AV7 +0.17 0.15 7 AV6 +0.02 0.07 4 AV3 +0.16 95 76 0.43 15 AV7 +0.00 0.55 18 AV6 +0.00 0.14 7 AV4 +0.00 95 78 0.50 17 AV7 +0.00 0.24 10 AV4 +0.03 95 80 0.21 9 AV3 -0.07 95 82 0.07 4 AV7 +0.00 0.39 14 AV5 -0.05 0.12 6 AV3 -0.02 0.11 6 AV2 -0.11 95 84 0.41 15 AV2 +0.00 0.06 4 AV1 -0.05 0.23 10 AV8 +0.07 0.60 19 AV7 -0.02 0.18 9 AV6 +0.12 95 86 0.16 8 AV8 -0.02 0.49 17 AV2 +0.02 95 88 0.16 8 AV8 +0.00 0.38 14 AV5 +0.02 0.22 10 AV3 +0.02 0.31 12 AV2 +0.02 95 90 0.22 10 AV7 -0.02 0.38 14 AV6 +0.00 0.37 14 AV4 +0.03 0.09 5 AV3 -0.16 0.07 5 AV2 -0.20 95 92 0.15 8 AV4 -0.14 0.23 10 AV7 +0.02 0.13 7 AV6 +0.07 0.13 7 AV3 -0.05 0.14 7 AV2 +0.02 95 94 0.48 17 AV7 +0.00 0.31 12 AV6 +0.00 0.43 15 AV5 +0.00 0.20 9 AV4 -0.05 0.30 12 AV3 +0.02 0.55 18 AV2 -0.02 0.23 10 AV1 -0.02 95 96 0.54 18 AV7 +0.00 0.36 14 AV3 +0.02 0.12 6 AV2 -0.07 95 98 0.19 9 AV7 +0.02 0.08 5 AV6 +0.21 0.08 5 AV5 +0.18 0.12 6 AV4 -0.21 0.16 8 AV2 -0.02 95 100 0.17 8 AV7 +0.05 0.20 9 AV6 +0.00 0.39 14 AV5 +0.05 0.55 18 AV4 +0.06 0.54 18 AV3 +0.00 0.43 15 AV2 +0.00 0.25 11 AV1 +0.00 95 102 0.19 9 AV4 +0.05 0.27 11 AV3 +0.00 95 104 0.45 16 AV8 +0.00 0.11 6 AV4 -0.21 0.19 9 AV3 +0.05 95 106 0.16 8 AV5 +0.00 95 110 0.15 8 AV3 +0.00 0.12 6 AV2 +0.02 95 112 0.07 4 AV4 -0.21 95 118 0.13 7 AV5 +0.02 95 120 0.10 5 AV4 +0.05 0.08 5 AV5 +0.16 96 39 0.15 8 AV4 +0.00 96 41 0.09 5 AV5 -0.18 96 43 0.09 5 AV4 -0.02 96 47 0.08 5 AV3 +0.17 96 49 0.09 5 AV6 +0.14 96 53 0.08 5 AV6 +0.21 0.12 6 AV4 -0.02 0.13 7 AV3 -0.07 96 57 0.09 5 AV4 +0.16 96 59 0.27 11 AV4 +0.05 96 61 0.07 4 AV4 +0.26 0.16 8 AV1 -0.02 96 65 0.08 5 AV6 -0.19 0.10 5 AV5 -0.21 96 67 0.14 7 AV4 +0.03 96 69 0.15 7 AV5 -0.03 0.08 5 AV4 -0.19 0.10 5 AV3 +0.00 96 71 0.46 16 AV3 +0.05 0.24 10 AV5 +0.03 0.15 7 AV2 -0.02 96 73 0.12 6 AV5 -0.21 0.28 11 AV4 -0.02 96 75 0.06 4 AV7 -0.07 0.30 12 AV6 -0.02 0.20 9 AV5 -0.03 0.07 5 AV4 -0.19 0.12 6 AV3 -0.21 96 77 0.24 10 AV8 +0.05 0.10 6 AV7 +0.00 0.62 19 AV6 +0.05 0.16 8 AV4 +0.05 0.43 15 AV2 -0.02 96 79 0.21 9 AV3 +0.05 96 81 0.18 9 AV8 +0.12 0.35 13 AV7 +0.00 0.09 5 AV6 -0.14 0.13 7 AV5 +0.23 0.11 6 AV4 +0.00 0.16 8 AV3 +0.00 0.07 5 AV2 -0.02 96 83 0.23 10 AV8 +0.02 0.36 14 AV7 -0.02 0.39 14 AV6 -0.05 0.58 19 AV5 -0.05 0.61 19 AV3 -0.02 0.29 12 AV2 +0.00 0.21 10 AV1 -0.02 96 87 0.29 12 AV7 +0.00 0.44 16 AV5 -0.05 0.50 17 AV4 +0.00 0.46 16 AV3 +0.00 0.26 11 AV2 +0.00 0.06 4 AV1 +0.05 96 89 0.24 10 AV7 +0.00 0.57 18 AV5 -0.03 0.16 8 AV4 -0.19 0.12 6 AV3 -0.14 0.06 4 AV8 -0.05 96 91 0.19 9 AV7 -0.02 0.43 15 AV6 +0.00 0.06 4 AV5 +0.26 0.13 7 AV4 +0.00 0.14 7 AV3 +0.00 0.15 7 AV2 +0.05 96 93 0.06 4 AV8 +0.49 0.14 7 AV4 +0.05 0.34 13 AV3 +0.02 0.21 9 AV2 +0.00 96 95 0.12 6 AV8 +0.00 0.16 8 AV7 +0.02 0.22 10 AV6 +0.02 0.20 9 AV5 +0.05 0.09 5 AV4 +0.34 0.09 5 AV3 -0.14 0.14 7 AV2 -0.05 96 97 0.09 5 AV8 +0.00 0.33 13 AV4 +0.00 0.33 13 AV3 -0.02 0.18 8 AV2 +0.02 96 99 0.10 5 AV5 +0.15 0.27 11 AV4 -0.02 0.13 7 AV3 -0.02 96 101 0.09 5 AV5 +0.00 0.16 8 AV4 +0.00 0.08 5 AV3 +0.00 96 103 0.25 11 AV5 -0.05 0.30 12 AV4 -0.03 96 105 0.16 8 AV4 +0.03 0.33 13 AV2 -0.02 96 107 0.27 11 AV5 -0.03 0.13 7 AV3 -0.02 96 109 0.10 6 AV7 -0.02 0.17 8 AV5 +0.02 96 115 0.15 7 AV4 +0.00 96 117 0.09 5 AV3 -0.05 97 34 0.16 8 AV3 +0.00 97 36 0.15 7 AV5 +0.00 97 42 0.11 6 AV6 +0.02 0.08 5 AV5 +0.15 97 46 0.07 4 AV5 -0.20 97 48 0.13 7 AV5 +0.05 97 50 0.18 9 AV4 +0.00 97 54 0.21 10 AV3 +0.02 97 56 0.09 5 AV6 +0.05 0.12 6 AV3 -0.19 97 58 0.11 6 AV6 +0.14 0.28 12 AV5 +0.00 0.15 7 AV4 +0.03 0.10 6 AV3 +0.02 97 60 0.16 8 AV4 +0.00 97 62 0.11 6 AV4 +0.05 0.17 8 AV3 +0.00 97 64 0.11 6 AV8 +0.00 0.23 10 AV6 +0.00 97 66 0.53 17 AV8 +0.02 97 68 0.26 11 AV5 -0.03 0.18 8 AV4 -0.05 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 71 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 16 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.11 6 AV3 -0.02 97 70 0.18 8 AV5 +0.18 0.14 7 AV4 -0.02 0.26 11 AV3 +0.00 0.31 12 AV2 +0.00 97 72 0.17 8 AV7 +0.16 0.32 13 AV6 +0.02 0.18 8 AV5 +0.21 0.10 6 AV4 +0.03 0.16 8 AV3 +0.00 0.08 5 AV2 -0.05 97 78 0.47 16 AV5 -0.03 0.19 9 AV4 -0.02 0.31 12 AV3 -0.02 0.38 14 AV7 -0.05 0.27 11 AV6 -0.02 97 80 0.13 7 AV7 +0.00 0.20 9 AV5 -0.03 0.18 8 AV3 -0.05 97 82 0.17 8 AV7 +0.00 0.41 15 AV6 +0.00 0.41 15 AV5 -0.03 0.20 9 AV4 +0.00 0.19 9 AV3 -0.02 0.18 9 AV2 -0.02 97 84 0.57 18 AV4 -0.02 0.35 13 AV3 -0.02 0.38 14 AV2 +0.00 0.29 12 AV7 +0.00 97 86 0.22 10 AV8 +0.00 0.62 19 AV6 -0.08 0.34 13 AV2 -0.02 97 88 0.24 11 AV7 -0.05 0.48 17 AV6 -0.03 0.47 16 AV5 -0.03 0.27 11 AV4 +0.00 0.18 8 AV3 -0.02 0.10 6 AV2 -0.02 97 90 0.53 17 AV7 +0.00 0.49 17 AV6 +0.00 0.22 10 AV5 +0.05 0.12 6 AV4 +0.05 0.48 17 AV3 -0.02 0.14 7 AV2 +0.00 0.06 4 AV1 +0.00 97 92 0.21 9 AV8 -0.02 0.48 17 AV7 -0.02 0.46 16 AV2 -0.02 97 94 0.20 9 AV2 -0.02 0.08 5 AV1 +0.16 0.24 10 AV7 -0.02 0.43 15 AV6 +0.00 0.09 5 AV5 +0.15 0.16 8 AV4 +0.00 0.27 11 AV3 +0.00 97 96 0.59 19 AV5 +0.00 0.15 7 AV4 -0.18 0.29 12 AV3 +0.00 0.17 8 AV2 +0.05 0.12 6 AV1 -0.05 97 98 0.58 18 AV7 +0.00 0.53 18 AV4 +0.00 0.27 11 AV3 -0.02 0.11 6 AV2 -0.02 97 100 0.46 16 AV6 +0.00 0.51 17 AV5 -0.03 0.16 8 AV4 -0.19 97 102 0.09 5 AV4 -0.03 0.08 5 AV1 -0.09 0.14 7 AV5 +0.00 97 104 0.52 17 AV7 -0.02 0.44 16 AV3 +0.05 97 106 0.11 6 AV7 +0.02 0.21 10 AV6 +0.00 0.18 9 AV3 +0.00 97 114 0.10 6 AV4 -0.14 97 118 0.10 6 AV5 +0.00 0.11 6 AV4 -0.12 98 27 0.17 8 AV1 -0.14 98 29 0.10 6 AV8 +0.09 0.07 4 AV2 +0.24 0.11 6 AV1 +0.07 98 39 0.11 6 AV5 +0.18 98 43 0.11 6 AV4 -0.05 98 49 0.11 6 AV5 -0.16 98 51 0.15 7 AV4 -0.02 98 53 0.20 9 AV6 +0.21 0.10 6 AV3 -0.21 98 57 0.15 8 AV4 -0.02 0.08 5 AV2 -0.07 98 59 0.08 5 AV5 +0.05 98 61 0.11 6 AV4 +0.21 98 63 0.09 5 AV7 +0.02 0.08 5 AV4 +0.03 98 65 0.14 7 AV7 +0.02 0.33 13 AV6 +0.02 98 67 0.13 7 AV4 +0.31 0.15 8 AV2 +0.00 0.10 6 AV1 +0.00 98 69 0.12 6 AV7 -0.16 0.11 6 AV4 -0.26 0.11 6 AV3 +0.17 0.07 4 AV2 -0.02 98 71 0.10 6 AV4 +0.10 0.08 5 AV3 +0.19 0.06 4 AV6 +0.24 98 73 0.11 6 AV5 +0.02 98 75 0.57 18 AV8 +0.02 0.62 19 AV6 +0.02 0.16 8 AV4 +0.00 0.33 13 AV3 +0.00 0.08 5 AV2 -0.05 98 77 0.16 8 AV8 +0.02 0.16 8 AV7 +0.00 0.14 7 AV6 +0.03 0.47 16 AV5 +0.05 0.17 8 AV4 +0.03 0.14 7 AV3 +0.00 98 79 0.12 6 AV7 -0.03 0.36 14 AV6 +0.08 0.15 7 AV5 +0.05 0.15 7 AV4 +0.03 98 81 0.26 11 AV5 +0.02 0.59 19 AV4 +0.00 0.34 13 AV3 +0.00 98 83 0.10 6 AV7 +0.02 0.08 5 AV6 +0.02 0.52 17 AV5 -0.03 0.52 17 AV4 -0.02 0.44 16 AV3 -0.02 0.19 9 AV2 -0.02 98 85 0.10 6 AV8 -0.12 0.51 17 AV6 +0.00 0.38 14 AV5 +0.03 0.12 6 AV1 +0.02 98 87 0.29 12 AV8 +0.00 0.62 19 AV5 -0.03 0.36 14 AV4 +0.00 0.18 9 AV3 +0.02 98 89 0.18 9 AV6 -0.03 0.34 13 AV5 +0.00 0.36 14 AV4 +0.00 0.16 8 AV3 -0.02 98 91 0.16 8 AV6 +0.00 0.48 17 AV5 +0.00 0.27 11 AV3 -0.05 0.08 5 AV2 +0.00 98 93 0.08 5 AV6 -0.17 0.33 13 AV5 +0.05 0.43 15 AV4 +0.03 0.10 6 AV3 -0.02 0.10 6 AV2 +0.00 0.06 4 AV1 +0.00 98 95 0.11 6 AV5 -0.03 0.08 5 AV3 -0.14 0.14 7 AV2 -0.21 0.05 4 AV1 -0.07 0.45 16 AV8 -0.02 98 97 0.17 8 AV8 -0.02 0.25 11 AV6 +0.00 0.58 18 AV5 +0.02 0.31 12 AV3 +0.02 0.52 17 AV2 +0.02 98 99 0.08 5 AV8 +0.02 0.23 10 AV4 +0.05 0.12 6 AV3 +0.02 0.11 6 AV2 -0.05 98 101 0.07 5 AV7 +0.16 0.12 6 AV6 +0.02 0.10 6 AV3 +0.00 0.12 6 AV2 -0.02 98 103 0.18 8 AV7 -0.05 0.58 19 AV5 +0.02 0.62 19 AV4 +0.03 0.27 11 AV2 +0.09 98 105 0.14 7 AV6 -0.05 0.21 9 AV3 +0.00 98 107 0.32 13 AV5 +0.00 98 109 0.09 5 AV4 +0.03 0.19 9 AV3 -0.02 98 111 0.13 7 AV5 +0.19 98 121 0.09 5 AV4 +0.05 0.09 5 AV3 -0.13 98 129 0.08 5 AV3 -0.20 0.09 5 AV2 -0.02 98 141 0.05 3 AV3 +0.16 99 30 0.12 6 AV1 +0.02 99 32 0.09 5 AV1 +0.18 99 38 0.07 5 AV2 +0.19 99 42 0.10 5 AV3 +0.19 99 44 0.10 6 AV4 +0.08 99 46 0.11 6 AV6 -0.16 0.06 4 AV5 +0.19 99 48 0.06 4 AV3 +0.40 99 50 0.11 6 AV4 +0.21 0.07 5 AV2 +0.12 99 52 0.10 6 AV4 +0.05 0.08 5 AV3 -0.05 99 54 0.08 5 AV6 +0.05 0.10 6 AV3 +0.02 99 56 0.41 15 AV3 +0.02 0.08 5 AV4 -0.14 99 58 0.19 9 AV3 +0.00 99 60 0.16 8 AV4 -0.21 99 62 0.11 6 AV4 +0.24 99 64 0.20 9 AV8 +0.05 0.08 5 AV4 -0.02 99 66 0.08 5 AV7 +0.20 0.13 7 AV3 +0.02 0.06 4 AV2 +0.00 99 68 0.21 10 AV4 -0.02 0.22 10 AV3 -0.05 0.19 9 AV2 -0.05 99 70 0.09 5 AV5 +0.14 0.08 5 AV4 +0.24 99 72 0.11 6 AV7 +0.12 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 72 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 17 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.27 11 AV6 +0.00 0.30 12 AV5 +0.21 0.07 4 AV3 -0.19 99 74 0.30 12 AV3 +0.02 0.38 14 AV4 +0.08 99 76 0.22 10 AV7 -0.05 0.45 16 AV5 -0.03 0.38 14 AV4 +0.00 0.41 15 AV3 +0.00 99 78 0.49 17 AV7 +0.00 0.45 16 AV6 +0.02 0.30 12 AV5 +0.21 0.10 6 AV4 -0.09 0.19 9 AV3 -0.02 99 80 0.15 8 AV7 +0.00 0.10 6 AV6 +0.19 0.40 15 AV4 +0.03 0.61 19 AV3 +0.02 0.09 5 AV2 +0.07 99 82 0.24 10 AV7 -0.05 0.26 11 AV6 -0.05 0.62 19 AV4 -0.02 0.11 6 AV2 -0.18 99 84 0.09 5 AV8 +0.07 0.15 7 AV7 -0.02 0.40 15 AV3 +0.00 0.44 16 AV2 -0.02 0.13 7 AV1 -0.07 99 86 0.16 8 AV8 +0.05 0.29 12 AV5 +0.02 0.11 6 AV1 +0.02 99 88 0.16 8 AV7 -0.07 0.34 13 AV6 +0.00 0.41 15 AV5 -0.03 0.20 9 AV4 +0.00 0.18 8 AV3 -0.02 0.12 6 AV2 -0.02 99 90 0.07 4 AV8 -0.05 0.18 9 AV7 +0.00 0.24 11 AV6 -0.02 0.14 7 AV5 +0.00 0.13 7 AV4 -0.21 0.13 7 AV3 -0.07 99 92 0.12 6 AV1 -0.02 99 94 0.11 6 AV7 +0.00 0.11 6 AV6 +0.19 0.21 10 AV4 +0.05 0.30 12 AV3 +0.05 0.25 11 AV2 +0.00 0.06 4 AV1 +0.02 99 96 0.08 5 AV7 +0.00 0.36 14 AV3 +0.02 0.09 5 AV1 -0.23 99 98 0.29 12 AV4 +0.03 0.08 5 AV2 -0.02 0.06 4 AV1 +0.00 99 100 0.19 9 AV5 -0.03 0.11 6 AV3 +0.00 99 102 0.38 14 AV5 -0.03 0.41 15 AV4 -0.03 0.14 7 AV3 -0.05 0.20 9 AV2 -0.02 0.18 8 AV1 -0.02 99 104 0.10 5 AV5 -0.25 0.12 6 AV3 -0.05 0.24 10 AV2 +0.14 99 108 0.11 6 AV5 +0.02 0.24 10 AV4 +0.00 0.53 17 AV3 +0.00 99 110 0.35 13 AV4 +0.03 99 116 0.11 6 AV4 +0.03 99 120 0.09 5 AV5 +0.23 99 124 0.05 4 AV4 +0.16 0.10 6 AV3 +0.23 0.06 4 AV1 +0.16 99 128 0.08 5 AV6 +0.11 99 132 0.18 8 AV5 +0.07 100 31 0.12 6 AV5 -0.03 0.10 6 AV2 +0.21 100 45 0.08 5 AV5 +0.23 100 47 0.08 5 AV4 +0.18 100 49 0.11 6 AV5 +0.23 0.16 8 AV4 +0.03 100 55 0.09 5 AV3 +0.05 100 57 0.10 6 AV2 -0.11 0.08 5 AV5 +0.35 0.08 5 AV4 +0.21 100 59 0.11 6 AV5 -0.05 100 63 0.54 18 AV7 +0.02 0.10 5 AV4 +0.18 100 65 0.30 12 AV7 +0.07 0.26 11 AV6 +0.00 0.10 6 AV5 -0.13 0.09 5 AV4 +0.03 0.31 12 AV3 -0.02 100 67 0.16 8 AV3 -0.02 100 71 0.28 12 AV8 -0.02 0.22 10 AV6 +0.03 0.15 7 AV5 +0.00 0.12 6 AV4 +0.03 0.27 11 AV3 +0.00 0.20 9 AV2 -0.02 100 73 0.09 5 AV1 +0.07 100 75 0.15 8 AV3 -0.11 100 77 0.25 11 AV4 +0.05 100 79 0.51 17 AV7 -0.02 0.42 15 AV6 +0.02 0.18 8 AV5 -0.05 100 81 0.09 5 AV6 -0.02 0.59 19 AV5 +0.00 0.26 11 AV4 +0.00 0.26 11 AV3 -0.02 0.10 6 AV2 -0.05 100 85 0.15 8 AV5 +0.02 0.50 17 AV3 -0.02 0.30 12 AV2 +0.00 0.06 4 AV1 +0.32 100 87 0.43 15 AV4 -0.02 0.09 5 AV3 -0.09 0.50 17 AV7 +0.00 100 89 0.07 4 AV7 -0.21 0.18 9 AV6 +0.00 0.42 15 AV5 +0.02 0.35 13 AV4 +0.05 0.17 8 AV3 -0.02 100 91 0.57 18 AV5 -0.03 0.16 8 AV4 -0.02 0.46 16 AV7 +0.02 0.44 16 AV6 +0.00 100 93 0.17 8 AV6 +0.02 0.28 11 AV4 -0.02 0.07 4 AV3 -0.05 0.09 5 AV2 -0.05 100 95 0.31 13 AV7 +0.02 0.06 4 AV6 -0.19 0.14 7 AV5 +0.07 0.11 6 AV4 +0.03 0.10 5 AV3 -0.07 0.18 8 AV2 -0.14 100 97 0.05 4 AV7 +0.00 0.06 4 AV6 +0.21 0.05 4 AV5 -0.16 0.25 11 AV3 +0.00 0.06 4 AV4 -0.19 0.33 13 AV2 +0.00 100 99 0.13 7 AV6 -0.22 0.55 18 AV4 +0.03 0.24 10 AV3 +0.00 0.16 8 AV2 -0.05 100 101 0.17 8 AV3 +0.00 0.12 6 AV7 +0.00 0.31 12 AV6 +0.05 0.18 9 AV5 +0.02 100 103 0.25 11 AV6 +0.05 0.41 15 AV5 +0.00 0.44 16 AV4 +0.00 0.58 18 AV3 +0.03 0.34 13 AV2 +0.05 100 105 0.14 7 AV6 -0.07 0.18 9 AV2 +0.02 100 135 0.14 7 AV4 -0.02 101 30 0.22 10 AV2 +0.02 0.27 11 AV1 -0.18 101 46 0.06 4 AV5 +0.00 0.21 9 AV6 +0.19 101 48 0.07 4 AV5 +0.16 0.12 6 AV4 -0.02 101 50 0.11 6 AV4 +0.03 0.20 9 AV3 +0.00 101 52 0.18 8 AV4 +0.03 101 54 0.14 7 AV4 -0.02 0.09 5 AV3 -0.02 101 56 0.13 7 AV4 -0.16 101 58 0.08 5 AV5 +0.16 101 60 0.16 8 AV4 -0.07 101 62 0.14 7 AV4 +0.00 101 64 0.26 11 AV8 +0.02 0.19 9 AV5 +0.00 0.14 7 AV4 +0.00 0.08 5 AV3 +0.16 101 66 0.08 5 AV7 +0.17 0.45 16 AV6 +0.00 0.62 19 AV5 +0.00 0.52 17 AV4 +0.00 101 70 0.10 6 AV6 +0.02 0.15 7 AV5 +0.18 101 72 0.15 7 AV5 +0.17 0.10 6 AV3 -0.05 101 74 0.30 12 AV6 +0.00 0.35 13 AV4 +0.03 0.13 7 AV2 +0.00 0.10 5 AV1 +0.00 101 76 0.19 9 AV3 +0.00 101 78 0.15 7 AV5 +0.14 101 80 0.11 6 AV5 -0.05 0.20 9 AV4 -0.02 0.10 6 AV2 -0.21 101 86 0.62 19 AV6 -0.05 0.18 8 AV3 -0.02 0.36 14 AV2 -0.07 101 88 0.16 8 AV7 -0.05 0.27 11 AV6 +0.02 0.16 8 AV5 -0.03 0.09 5 AV4 -0.19 0.16 8 AV3 -0.02 0.09 5 AV2 -0.14 101 90 0.43 15 AV8 +0.02 0.39 14 AV6 +0.02 0.32 13 AV5 +0.05 0.10 6 AV4 +0.03 0.15 8 AV3 -0.14 0.15 7 AV2 -0.02 101 92 0.18 9 AV7 -0.21 0.19 9 AV6 +0.00 0.60 19 AV5 -0.06 0.13 7 AV4 -0.19 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 73 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 18 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.22 10 AV3 -0.07 0.16 8 AV2 -0.07 101 94 0.14 7 AV7 -0.02 0.19 9 AV6 -0.03 0.28 12 AV4 -0.07 0.17 8 AV3 +0.00 0.14 7 AV2 -0.05 101 96 0.13 7 AV7 +0.02 0.11 6 AV5 +0.19 0.17 8 AV4 +0.00 0.45 16 AV3 +0.00 0.28 12 AV2 +0.02 101 98 0.19 9 AV8 -0.02 0.26 11 AV6 +0.02 0.33 13 AV5 +0.00 0.59 19 AV2 +0.00 0.23 10 AV1 +0.00 101 100 0.25 11 AV4 -0.02 0.14 7 AV2 -0.05 101 104 0.21 10 AV6 +0.00 0.21 9 AV3 +0.00 101 106 0.10 6 AV2 -0.05 101 110 0.14 7 AV5 +0.00 101 112 0.29 12 AV3 +0.00 0.10 6 AV2 -0.21 101 118 0.12 6 AV4 -0.02 101 140 0.14 7 AV7 +0.02 0.12 6 AV6 +0.03 0.07 5 AV2 -0.18 102 31 0.10 6 AV6 -0.19 0.08 5 AV3 +0.17 0.10 6 AV2 +0.14 102 47 0.28 11 AV6 +0.00 0.08 5 AV5 -0.03 0.19 9 AV4 -0.02 102 51 0.10 6 AV4 -0.05 102 65 0.21 10 AV4 +0.05 0.17 8 AV2 -0.02 102 71 0.29 12 AV6 +0.00 102 73 0.36 14 AV5 -0.03 102 75 0.41 15 AV8 +0.02 0.25 11 AV3 -0.02 0.13 7 AV2 +0.00 0.07 5 AV1 -0.02 102 77 0.32 13 AV5 -0.03 0.17 8 AV4 -0.07 0.38 14 AV7 -0.03 0.25 11 AV6 +0.00 102 79 0.12 6 AV6 +0.00 0.24 10 AV4 +0.00 0.12 6 AV3 -0.21 102 81 0.48 17 AV7 +0.00 0.63 19 AV4 +0.03 0.15 8 AV2 +0.00 102 83 0.10 6 AV8 -0.02 0.23 10 AV3 -0.05 0.10 6 AV2 -0.02 102 85 0.11 6 AV8 -0.02 0.41 15 AV5 +0.02 0.56 18 AV4 +0.03 0.63 19 AV2 +0.00 0.39 14 AV1 -0.02 102 87 0.08 5 AV8 +0.14 0.48 16 AV4 +0.00 0.21 9 AV3 -0.02 0.58 19 AV2 -0.02 0.16 8 AV1 -0.05 102 89 0.52 17 AV7 +0.00 0.18 9 AV1 -0.05 102 91 0.20 9 AV4 -0.05 0.39 14 AV3 -0.07 0.32 13 AV2 +0.00 102 93 0.12 6 AV7 +0.02 0.16 8 AV5 +0.00 0.29 12 AV4 +0.03 0.15 7 AV2 +0.00 0.09 5 AV1 -0.05 102 95 0.17 8 AV2 -0.02 0.09 5 AV8 +0.00 0.11 6 AV7 +0.00 0.42 15 AV6 +0.00 0.11 6 AV5 -0.03 0.14 7 AV4 -0.02 0.11 6 AV3 -0.02 102 97 0.48 16 AV3 -0.02 0.40 15 AV2 +0.00 0.25 11 AV1 -0.02 0.50 17 AV8 -0.02 102 99 0.16 8 AV4 -0.02 102 109 0.14 7 AV5 +0.02 0.42 15 AV3 +0.00 0.33 13 AV2 -0.02 102 113 0.09 5 AV5 +0.15 102 115 0.14 7 AV4 +0.03 102 119 0.10 5 AV5 +0.00 0.12 6 AV4 -0.02 103 44 0.11 6 AV5 +0.19 103 48 0.10 6 AV5 -0.10 103 52 0.08 5 AV3 +0.07 103 54 0.05 4 AV3 +0.29 103 56 0.11 6 AV6 -0.09 0.13 7 AV5 -0.13 0.15 7 AV4 -0.14 103 58 0.11 6 AV6 -0.12 103 60 0.12 6 AV4 -0.21 103 64 0.08 5 AV4 +0.16 103 66 0.13 7 AV6 -0.09 0.11 6 AV4 +0.00 0.07 4 AV2 +0.14 103 70 0.10 6 AV5 -0.16 103 72 0.13 7 AV6 +0.12 0.10 6 AV5 +0.21 0.11 6 AV4 -0.05 0.06 4 AV3 -0.23 103 74 0.16 8 AV7 +0.02 0.23 10 AV6 +0.02 0.18 8 AV5 -0.03 0.09 5 AV4 +0.16 0.13 7 AV3 +0.14 103 76 0.41 15 AV6 +0.00 0.20 9 AV5 +0.00 0.15 7 AV4 -0.02 0.11 6 AV3 -0.05 103 78 0.13 7 AV5 +0.14 103 80 0.10 6 AV5 +0.05 0.11 6 AV1 +0.05 103 82 0.10 6 AV5 +0.26 0.08 5 AV3 -0.14 103 84 0.14 7 AV8 +0.05 0.60 19 AV6 +0.02 0.55 18 AV4 +0.00 0.42 15 AV2 -0.02 0.06 4 AV1 +0.00 103 86 0.27 11 AV7 -0.02 0.50 17 AV6 +0.02 0.19 9 AV3 +0.00 0.45 16 AV2 -0.05 103 88 0.20 9 AV5 -0.05 0.09 5 AV4 -0.16 0.23 10 AV3 -0.05 0.40 15 AV8 +0.02 0.41 15 AV7 -0.05 0.48 16 AV6 +0.00 103 90 0.09 5 AV8 -0.02 0.59 19 AV7 -0.02 0.19 9 AV6 -0.02 0.13 7 AV5 -0.05 0.17 8 AV3 -0.25 0.13 7 AV2 -0.09 103 92 0.44 16 AV8 +0.05 0.50 17 AV7 +0.02 0.45 16 AV6 +0.00 0.44 16 AV3 +0.00 0.63 19 AV2 +0.00 0.10 6 AV1 +0.00 103 94 0.17 8 AV5 +0.00 0.46 16 AV4 +0.00 0.44 16 AV3 +0.02 0.10 5 AV2 -0.02 103 96 0.14 7 AV7 +0.05 0.06 4 AV6 +0.56 0.08 5 AV5 +0.16 0.46 16 AV4 -0.02 0.28 12 AV3 +0.00 103 98 0.22 10 AV7 +0.00 0.24 10 AV5 -0.05 0.11 6 AV4 +0.00 0.09 5 AV2 -0.18 103 100 0.15 8 AV7 +0.02 0.18 9 AV6 -0.02 0.18 9 AV5 -0.03 103 104 0.08 5 AV4 -0.17 103 110 0.11 6 AV5 -0.03 103 120 0.15 7 AV4 +0.00 103 124 0.16 8 AV5 +0.00 103 126 0.11 6 AV4 +0.00 104 45 0.08 5 AV6 -0.12 104 49 0.09 5 AV3 +0.00 104 55 0.06 4 AV5 -0.08 0.10 6 AV4 +0.00 104 59 0.08 5 AV4 +0.08 104 61 0.07 4 AV4 +0.03 0.17 8 AV3 -0.16 104 63 0.12 6 AV6 -0.19 0.12 6 AV5 -0.03 0.09 5 AV4 -0.02 104 71 0.07 4 AV7 +0.50 0.09 5 AV3 -0.05 0.08 5 AV2 -0.21 104 73 0.08 5 AV4 +0.18 0.11 6 AV3 +0.00 0.09 5 AV2 -0.21 104 77 0.31 12 AV7 -0.02 0.19 9 AV6 +0.14 0.10 6 AV5 -0.16 0.14 7 AV4 -0.05 0.11 6 AV3 +0.00 104 79 0.07 4 AV3 +0.23 0.08 5 AV2 +0.00 104 81 0.17 8 AV7 -0.07 0.24 10 AV6 +0.00 0.28 12 AV5 -0.03 0.10 6 AV4 -0.16 0.37 14 AV3 -0.02 104 83 0.43 15 AV8 +0.00 0.18 9 AV7 -0.21 0.11 6 AV3 -0.05 104 87 0.10 6 AV7 +0.00 0.24 10 AV6 +0.14 0.37 14 AV4 +0.00 0.15 7 AV3 -0.20 0.13 7 AV2 -0.07 0.11 6 AV1 -0.21 104 89 0.18 9 AV7 +0.02 0.09 5 AV6 +0.02 0.15 7 AV5 +0.14 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 74 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 19 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.13 7 AV4 -0.21 0.18 8 AV3 -0.18 104 91 0.10 6 AV8 +0.02 0.28 12 AV6 +0.02 0.35 14 AV2 +0.02 0.10 6 AV1 +0.46 104 93 0.14 7 AV3 +0.00 104 95 0.10 6 AV7 +0.17 0.07 4 AV6 -0.14 0.26 11 AV5 +0.02 0.10 5 AV4 -0.16 0.17 8 AV3 +0.00 0.33 13 AV2 -0.02 0.14 7 AV1 +0.00 104 97 0.15 7 AV6 -0.02 0.52 17 AV5 -0.03 0.33 13 AV3 -0.05 0.18 8 AV2 -0.02 104 99 0.09 5 AV1 -0.05 0.11 6 AV7 -0.02 0.10 6 AV6 +0.00 0.09 5 AV5 +0.02 0.06 4 AV4 +0.03 0.50 17 AV3 +0.02 0.18 8 AV2 +0.00 104 105 0.15 8 AV4 +0.00 104 107 0.19 9 AV4 +0.00 104 109 0.08 5 AV4 -0.14 104 121 0.12 7 AV4 -0.16 104 127 0.09 5 AV5 +0.05 104 133 0.13 7 AV7 +0.02 105 38 0.10 6 AV6 +0.00 105 54 0.25 11 AV5 +0.02 0.13 7 AV4 +0.05 0.17 8 AV3 +0.00 105 58 0.08 5 AV4 -0.14 0.13 7 AV3 +0.00 105 64 0.12 6 AV5 +0.14 105 70 0.18 8 AV6 +0.00 105 72 0.52 17 AV2 +0.00 0.11 6 AV1 -0.02 0.18 8 AV6 +0.05 0.26 11 AV5 +0.02 105 74 0.24 10 AV7 +0.02 0.46 16 AV6 +0.02 0.13 7 AV4 +0.00 0.23 10 AV3 +0.02 105 76 0.09 5 AV4 +0.13 105 78 0.32 13 AV5 +0.02 0.15 7 AV4 +0.03 0.16 8 AV3 -0.05 0.24 10 AV2 +0.00 105 80 0.17 8 AV6 +0.02 0.09 5 AV5 +0.14 0.09 5 AV2 +0.00 105 82 0.12 6 AV7 +0.02 0.24 11 AV6 -0.03 0.22 10 AV5 -0.03 0.25 11 AV4 -0.02 0.51 17 AV3 -0.02 105 86 0.25 11 AV3 -0.02 0.42 15 AV2 -0.05 0.29 12 AV8 +0.00 105 88 0.12 6 AV5 +0.00 0.13 7 AV4 +0.03 0.37 14 AV3 -0.05 0.27 11 AV2 -0.02 0.19 9 AV1 -0.02 105 90 0.12 6 AV8 -0.02 0.63 19 AV7 -0.02 0.17 8 AV6 +0.02 0.44 16 AV5 -0.03 0.15 7 AV4 -0.02 0.13 7 AV3 -0.07 0.09 5 AV2 -0.05 105 92 0.13 7 AV7 +0.00 0.19 9 AV6 +0.02 0.24 10 AV3 +0.00 0.11 6 AV2 +0.16 0.09 5 AV1 +0.00 105 94 0.07 4 AV7 +0.02 0.15 8 AV6 +0.00 0.09 5 AV5 -0.03 0.21 9 AV4 -0.02 0.16 8 AV3 -0.02 0.11 6 AV2 -0.18 105 96 0.14 7 AV6 +0.00 0.14 7 AV4 +0.00 0.28 11 AV3 +0.00 0.39 14 AV2 +0.00 0.18 9 AV1 -0.02 105 98 0.14 7 AV2 -0.02 0.06 4 AV1 +0.11 0.12 6 AV7 -0.02 0.23 10 AV5 +0.00 0.21 9 AV4 +0.03 0.42 15 AV3 +0.05 105 100 0.15 7 AV7 +0.16 0.15 7 AV6 +0.00 0.21 10 AV4 +0.03 105 112 0.10 6 AV5 +0.02 0.28 12 AV3 -0.02 106 33 0.05 4 AV7 +0.26 0.23 10 AV6 +0.00 106 41 0.18 8 AV6 +0.02 106 43 0.14 7 AV5 -0.03 106 53 0.10 6 AV5 +0.21 0.10 6 AV4 +0.21 0.08 5 AV3 +0.00 0.22 10 AV2 +0.02 0.08 5 AV1 +0.11 106 55 0.06 4 AV5 +0.21 0.15 8 AV4 +0.00 106 57 0.17 8 AV4 +0.00 106 59 0.14 7 AV5 +0.05 106 61 0.12 6 AV5 -0.24 0.08 5 AV4 +0.03 0.08 5 AV3 +0.21 106 63 0.06 4 AV5 +0.00 0.09 5 AV3 +0.05 106 65 0.12 6 AV6 -0.03 106 67 0.10 6 AV4 +0.00 0.08 5 AV3 +0.09 106 71 0.09 5 AV5 -0.21 0.15 7 AV4 +0.00 0.10 5 AV3 -0.18 106 73 0.16 8 AV6 +0.00 0.12 6 AV5 -0.03 0.14 7 AV4 -0.02 0.13 7 AV3 -0.07 106 75 0.09 5 AV4 +0.00 0.28 12 AV3 +0.00 0.17 8 AV2 -0.02 106 77 0.12 6 AV5 -0.03 0.14 7 AV3 -0.05 106 81 0.44 16 AV7 -0.02 0.33 13 AV6 -0.02 0.33 13 AV5 -0.03 0.49 17 AV4 +0.00 0.17 8 AV3 -0.02 106 83 0.44 16 AV5 -0.03 0.16 8 AV2 -0.02 0.15 8 AV1 -0.02 106 85 0.19 9 AV4 +0.03 0.28 11 AV1 +0.00 106 87 0.13 7 AV8 +0.02 0.10 6 AV7 -0.21 0.50 17 AV6 +0.12 0.21 9 AV5 -0.06 0.13 7 AV4 +0.00 0.54 18 AV2 -0.02 0.20 9 AV1 -0.02 106 89 0.13 7 AV2 -0.05 0.26 11 AV7 -0.05 0.15 8 AV6 -0.02 0.15 7 AV5 +0.15 0.14 7 AV4 -0.19 0.16 8 AV3 -0.05 106 91 0.21 9 AV7 +0.02 0.29 12 AV6 +0.00 0.34 13 AV4 -0.05 0.12 6 AV3 -0.07 106 93 0.24 10 AV6 +0.00 0.35 13 AV5 +0.02 0.37 14 AV4 +0.00 0.20 9 AV3 +0.02 0.38 14 AV2 +0.00 0.12 6 AV1 -0.05 106 95 0.17 8 AV6 -0.02 0.37 14 AV5 -0.03 0.46 16 AV4 -0.02 0.22 10 AV3 -0.02 0.22 10 AV2 -0.05 0.15 7 AV7 +0.00 106 97 0.12 6 AV7 +0.00 0.06 4 AV6 +0.19 0.31 12 AV5 +0.00 0.51 17 AV4 +0.08 0.27 11 AV1 -0.02 106 99 0.08 5 AV4 -0.05 0.10 6 AV3 -0.02 0.10 6 AV2 +0.11 106 101 0.13 7 AV5 +0.17 106 103 0.10 6 AV6 +0.07 0.10 5 AV5 +0.15 0.14 7 AV4 -0.02 106 111 0.13 7 AV5 +0.00 106 119 0.14 7 AV7 +0.02 0.11 6 AV4 -0.02 106 129 0.09 5 AV3 -0.02 107 34 0.21 9 AV8 +0.00 0.06 4 AV7 -0.19 0.10 5 AV6 -0.19 0.18 9 AV2 +0.14 0.14 7 AV1 +0.07 107 46 0.27 11 AV6 +0.02 0.09 5 AV3 +0.41 107 50 0.08 5 AV7 -0.12 107 56 0.12 6 AV5 -0.10 0.09 5 AV4 +0.03 0.07 4 AV3 -0.30 107 60 0.06 4 AV5 +0.30 0.12 6 AV4 -0.19 0.10 6 AV2 +0.12 107 62 0.07 4 AV3 +0.14 107 64 0.09 5 AV6 -0.12 0.09 5 AV2 +0.07 0.08 5 AV5 +0.21 107 66 0.08 5 AV5 -0.11 107 68 0.09 5 AV4 +0.13 0.11 6 AV3 -0.21 0.10 6 AV2 +0.14 107 70 0.11 6 AV8 -0.05 0.19 9 AV6 +0.00 0.14 7 AV5 +0.16 0.10 6 AV4 +0.26 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 75 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 20 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 107 72 0.09 5 AV7 -0.27 0.10 6 AV2 +0.05 107 74 0.10 6 AV3 +0.14 107 76 0.10 6 AV5 +0.14 0.50 17 AV4 -0.02 0.37 14 AV3 -0.02 0.14 7 AV2 -0.02 107 78 0.62 19 AV7 +0.00 0.24 10 AV5 +0.02 0.08 5 AV4 +0.03 0.12 6 AV3 -0.21 0.05 4 AV1 -0.05 107 80 0.25 11 AV7 -0.02 0.13 7 AV6 +0.02 0.13 7 AV4 -0.19 107 82 0.14 7 AV7 +0.02 0.15 7 AV6 +0.00 0.49 17 AV5 -0.03 0.50 17 AV4 -0.02 0.37 14 AV3 -0.05 0.12 6 AV2 -0.21 107 84 0.42 15 AV3 -0.02 0.10 6 AV2 -0.02 107 88 0.17 8 AV7 -0.02 0.16 8 AV6 +0.02 0.44 16 AV5 +0.00 0.46 16 AV4 +0.03 0.26 11 AV3 -0.02 0.11 6 AV2 -0.02 0.08 5 AV1 -0.02 107 90 0.11 6 AV7 +0.09 0.10 6 AV6 +0.05 0.14 7 AV5 +0.05 0.15 7 AV4 +0.05 0.13 7 AV3 -0.07 0.15 7 AV2 +0.02 107 92 0.46 16 AV7 +0.02 0.11 6 AV6 +0.07 0.11 6 AV1 -0.07 107 94 0.52 17 AV6 +0.00 0.27 11 AV4 +0.00 0.16 8 AV3 +0.05 0.35 14 AV2 -0.02 0.08 5 AV1 -0.02 107 96 0.47 16 AV4 +0.00 0.60 19 AV3 -0.02 107 98 0.04 3 AV7 +0.21 0.14 7 AV6 +0.05 0.18 9 AV4 -0.05 0.11 6 AV3 -0.18 0.18 8 AV2 -0.02 0.06 4 AV1 +0.32 107 100 0.18 8 AV7 +0.05 0.07 5 AV6 +0.14 0.21 10 AV5 -0.03 0.30 12 AV4 -0.02 0.11 6 AV2 -0.02 107 104 0.11 6 AV4 -0.02 107 108 0.09 5 AV5 -0.03 107 112 0.13 7 AV5 -0.03 107 128 0.09 5 AV5 +0.02 0.10 6 AV4 +0.03 108 35 0.10 6 AV2 +0.14 108 45 0.09 5 AV3 +0.14 108 49 0.45 16 AV6 +0.05 0.15 8 AV5 +0.05 0.07 5 AV4 -0.12 108 61 0.09 5 AV5 -0.18 0.09 5 AV3 -0.21 108 65 0.11 6 AV5 -0.13 0.10 6 AV4 -0.16 0.09 5 AV3 +0.07 0.12 6 AV6 +0.00 108 67 0.09 5 AV7 -0.15 0.15 7 AV6 +0.00 0.11 6 AV3 +0.02 108 71 0.22 10 AV5 +0.00 0.08 5 AV4 +0.03 0.24 10 AV6 +0.00 108 73 0.10 5 AV6 +0.28 0.08 5 AV2 +0.07 0.09 5 AV5 -0.22 108 75 0.10 6 AV4 +0.10 0.18 9 AV3 -0.23 108 77 0.10 5 AV6 +0.00 0.09 5 AV5 -0.23 0.10 6 AV3 -0.21 0.14 7 AV2 -0.16 108 79 0.07 4 AV6 +0.23 0.10 6 AV5 +0.00 0.11 6 AV4 +0.13 108 81 0.11 6 AV7 +0.05 0.09 5 AV2 +0.25 108 83 0.29 12 AV8 +0.02 0.61 19 AV4 -0.02 0.63 19 AV3 -0.02 0.28 12 AV2 -0.02 0.16 8 AV1 -0.02 108 87 0.28 11 AV4 -0.02 0.58 18 AV5 -0.03 0.08 5 AV7 +0.05 0.40 15 AV6 +0.12 108 89 0.12 6 AV7 +0.02 0.30 12 AV6 -0.02 0.31 13 AV5 -0.03 0.10 6 AV4 -0.21 0.11 6 AV3 -0.02 0.10 5 AV2 -0.11 108 91 0.10 6 AV7 +0.14 0.57 18 AV3 +0.02 0.51 17 AV2 +0.00 108 93 0.18 8 AV1 -0.05 0.47 16 AV2 +0.00 0.40 15 AV3 +0.02 0.08 5 AV7 +0.19 0.34 13 AV4 +0.05 108 95 0.36 14 AV5 +0.02 0.53 18 AV4 +0.05 0.62 19 AV2 +0.00 0.12 6 AV1 +0.02 108 97 0.06 4 AV8 -0.41 0.20 9 AV7 +0.00 0.24 10 AV6 -0.02 0.24 10 AV5 -0.03 0.25 11 AV4 -0.05 108 99 0.20 9 AV8 +0.02 0.46 16 AV3 +0.00 108 101 0.16 8 AV6 +0.02 0.33 13 AV5 -0.03 0.25 11 AV3 -0.05 108 105 0.23 10 AV5 +0.00 108 107 0.14 7 AV5 +0.02 108 115 0.11 6 AV4 +0.00 0.08 5 AV3 -0.18 108 117 0.12 6 AV5 +0.05 0.18 8 AV4 +0.00 108 123 0.09 5 AV8 +0.05 108 125 0.22 10 AV5 +0.02 0.27 11 AV4 +0.05 0.09 5 AV3 +0.00 108 137 0.12 6 AV5 +0.15 109 48 0.08 5 AV6 -0.03 0.13 7 AV5 -0.05 109 54 0.09 5 AV5 +0.02 109 62 0.18 9 AV5 +0.00 0.14 7 AV4 -0.02 109 64 0.14 7 AV7 +0.05 0.13 7 AV6 +0.00 0.10 6 AV5 +0.12 109 66 0.16 8 AV7 +0.05 0.33 13 AV6 +0.02 0.21 9 AV5 +0.02 0.29 12 AV4 +0.05 0.10 6 AV3 +0.00 0.28 12 AV2 +0.00 109 68 0.27 11 AV7 +0.02 0.13 7 AV5 +0.12 0.27 11 AV4 -0.02 0.07 4 AV2 +0.39 109 70 0.09 5 AV7 +0.47 0.12 6 AV4 -0.05 0.12 6 AV3 -0.05 109 72 0.33 13 AV4 -0.07 0.11 6 AV3 -0.02 109 74 0.09 5 AV7 +0.00 0.14 7 AV3 -0.02 109 76 0.09 5 AV7 +0.12 0.05 4 AV6 +0.24 0.14 7 AV4 -0.05 109 78 0.15 7 AV5 +0.14 109 80 0.15 8 AV3 -0.02 0.10 6 AV2 -0.05 109 82 0.11 6 AV7 +0.14 0.46 16 AV5 +0.00 0.34 13 AV4 +0.16 0.16 8 AV3 -0.21 109 84 0.22 10 AV8 +0.07 0.36 14 AV6 +0.03 0.51 17 AV3 -0.05 0.27 11 AV2 -0.02 0.33 13 AV1 +0.00 109 86 0.20 9 AV8 +0.02 0.35 13 AV3 -0.02 0.27 11 AV2 -0.05 109 88 0.11 6 AV6 +0.00 0.22 10 AV4 -0.07 0.20 9 AV3 +0.00 0.16 8 AV2 -0.02 0.07 4 AV1 -0.05 109 90 0.10 6 AV8 +0.05 0.20 9 AV6 +0.00 0.13 7 AV5 +0.17 0.10 6 AV4 +0.00 0.26 11 AV3 -0.07 109 92 0.20 9 AV7 -0.19 0.09 5 AV6 +0.19 0.13 7 AV5 -0.03 0.36 14 AV4 +0.00 0.22 10 AV3 +0.00 0.13 7 AV2 -0.02 109 94 0.11 6 AV6 -0.02 0.42 15 AV5 +0.02 0.30 12 AV4 -0.02 0.21 9 AV3 -0.02 0.27 11 AV2 +0.00 0.08 5 AV1 -0.02 109 96 0.29 12 AV4 -0.02 0.13 7 AV3 -0.02 109 98 0.18 9 AV6 +0.21 0.15 8 AV5 +0.05 0.09 5 AV1 +0.00 109 100 0.15 7 AV7 +0.02 0.25 11 AV5 +0.05 0.32 13 AV4 +0.05 0.46 16 AV3 +0.05 0.34 13 AV2 +0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 76 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 21 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.07 4 AV1 +0.12 109 102 0.11 6 AV4 -0.19 0.10 6 AV3 -0.09 0.10 6 AV2 -0.02 109 104 0.11 6 AV5 -0.03 109 106 0.06 4 AV5 +0.19 0.10 6 AV2 -0.19 109 112 0.13 7 AV2 +0.02 109 114 0.19 9 AV7 +0.07 0.17 8 AV6 +0.05 0.13 7 AV5 +0.12 0.23 10 AV3 +0.05 109 130 0.12 6 AV6 +0.02 109 136 0.09 5 AV7 -0.17 110 51 0.23 10 AV5 +0.34 110 53 0.18 8 AV5 +0.07 0.12 6 AV4 +0.18 0.08 5 AV3 +0.17 110 59 0.12 6 AV5 +0.05 0.10 6 AV4 +0.05 0.08 5 AV3 +0.00 110 67 0.12 6 AV3 +0.14 110 69 0.18 9 AV5 -0.05 0.17 8 AV4 -0.02 110 71 0.07 5 AV6 +0.20 0.10 6 AV4 +0.00 0.10 5 AV3 +0.09 110 73 0.13 7 AV4 -0.14 0.13 7 AV3 -0.21 110 75 0.20 9 AV5 +0.00 0.18 9 AV3 -0.14 110 77 0.09 5 AV7 +0.00 0.10 6 AV6 +0.18 0.29 12 AV5 +0.00 0.22 10 AV4 -0.05 0.28 11 AV3 -0.02 0.12 7 AV2 +0.00 110 79 0.20 9 AV4 -0.02 0.11 6 AV3 -0.18 0.10 6 AV2 -0.21 110 81 0.14 7 AV4 +0.00 110 83 0.41 15 AV6 -0.02 0.10 5 AV3 -0.02 110 85 0.40 15 AV6 -0.03 0.37 14 AV2 -0.02 110 87 0.28 12 AV8 +0.00 0.48 17 AV7 -0.02 0.16 8 AV5 -0.03 0.41 15 AV4 -0.02 0.08 5 AV2 +0.28 110 89 0.27 11 AV7 +0.00 0.53 18 AV5 +0.02 0.12 6 AV4 -0.16 0.08 5 AV2 -0.02 110 91 0.13 7 AV8 +0.00 0.32 13 AV7 +0.00 0.25 11 AV6 +0.00 0.44 16 AV5 +0.00 0.17 8 AV4 +0.00 0.14 7 AV3 -0.05 110 93 0.22 10 AV7 +0.02 0.09 5 AV5 -0.03 0.32 13 AV4 +0.00 0.19 9 AV2 +0.00 110 95 0.21 10 AV2 -0.02 0.08 5 AV6 -0.05 0.19 9 AV5 -0.03 0.28 11 AV3 -0.05 110 97 0.07 5 AV7 +0.14 0.12 6 AV5 +0.00 0.09 5 AV4 -0.21 0.49 17 AV3 -0.02 110 99 0.40 15 AV5 +0.00 0.25 11 AV4 +0.00 0.14 7 AV3 -0.04 0.08 5 AV2 -0.32 110 101 0.35 13 AV4 -0.02 0.41 15 AV3 -0.02 0.28 12 AV2 +0.00 0.13 7 AV1 -0.02 0.42 15 AV7 +0.00 110 103 0.19 9 AV6 +0.07 0.19 9 AV4 +0.00 0.29 12 AV3 -0.02 0.14 7 AV2 -0.02 110 107 0.12 6 AV4 -0.02 110 127 0.13 7 AV7 -0.16 0.13 7 AV4 +0.00 110 129 0.18 8 AV5 +0.00 111 50 0.16 8 AV6 +0.36 111 72 0.10 6 AV6 -0.14 0.09 5 AV4 -0.02 111 74 0.08 5 AV6 +0.07 0.14 7 AV3 +0.00 111 76 0.14 7 AV3 -0.18 0.18 8 AV2 -0.07 0.18 9 AV4 -0.02 111 78 0.11 6 AV5 -0.05 0.29 12 AV4 +0.00 0.09 5 AV3 +0.07 111 80 0.09 5 AV7 +0.00 111 82 0.17 8 AV5 +0.00 0.08 5 AV3 +0.21 111 84 0.47 16 AV7 +0.00 0.41 15 AV6 +0.02 0.07 4 AV2 +0.14 111 86 0.55 18 AV8 +0.00 0.16 8 AV5 -0.03 0.25 11 AV3 -0.02 0.21 10 AV2 -0.07 111 88 0.20 9 AV6 +0.02 0.19 9 AV5 -0.03 0.31 12 AV4 +0.00 0.23 10 AV3 -0.07 0.12 6 AV2 -0.25 111 90 0.15 7 AV6 +0.00 0.36 14 AV5 -0.03 0.20 9 AV3 -0.07 111 92 0.11 6 AV7 +0.19 0.09 5 AV6 +0.31 0.10 6 AV5 +0.14 0.09 5 AV4 -0.16 0.17 8 AV3 -0.02 0.27 11 AV2 +0.00 0.07 5 AV1 -0.12 111 94 0.11 6 AV6 +0.02 0.16 8 AV4 +0.00 0.24 10 AV3 -0.02 0.11 6 AV2 -0.02 111 96 0.10 5 AV7 -0.17 0.54 18 AV4 -0.02 0.25 11 AV3 -0.05 0.20 9 AV2 -0.05 0.20 9 AV1 -0.02 111 98 0.33 13 AV8 +0.02 0.37 14 AV7 +0.02 0.25 11 AV6 +0.02 0.23 10 AV5 +0.00 0.50 17 AV4 +0.00 0.27 11 AV3 +0.02 0.21 9 AV2 +0.00 0.04 3 AV1 -0.14 111 100 0.12 6 AV3 +0.00 0.10 6 AV2 -0.05 111 102 0.40 15 AV8 +0.00 0.53 17 AV4 -0.02 0.58 18 AV2 -0.02 111 128 0.10 6 AV5 -0.23 0.18 9 AV4 +0.00 112 63 0.18 9 AV8 +0.07 0.42 15 AV7 +0.02 0.13 7 AV6 +0.00 0.16 8 AV5 -0.03 112 69 0.17 8 AV4 -0.02 0.22 10 AV3 -0.05 0.34 13 AV2 -0.02 0.22 10 AV1 -0.05 112 71 0.12 6 AV6 +0.00 0.22 10 AV4 +0.00 0.19 9 AV3 -0.02 0.14 7 AV2 -0.21 112 73 0.46 16 AV6 -0.02 0.30 12 AV4 +0.00 0.47 16 AV3 +0.00 0.13 7 AV2 +0.00 0.30 12 AV1 -0.02 0.11 6 AV8 +0.02 0.59 19 AV7 +0.02 112 81 0.08 5 AV4 -0.38 112 87 0.11 6 AV7 +0.02 0.16 8 AV6 +0.16 0.36 14 AV5 +0.00 0.18 9 AV3 -0.02 112 89 0.20 9 AV6 +0.00 0.11 6 AV5 +0.14 0.12 6 AV4 -0.19 0.10 6 AV3 -0.02 0.17 8 AV2 -0.11 0.14 7 AV7 +0.02 112 91 0.17 8 AV7 -0.12 0.16 8 AV5 -0.03 0.51 17 AV4 -0.02 0.27 11 AV3 -0.02 0.11 6 AV2 -0.05 0.08 5 AV1 -0.02 112 93 0.09 5 AV5 +0.05 0.07 4 AV4 +0.05 0.21 10 AV2 -0.02 0.06 4 AV1 +0.07 112 95 0.08 5 AV7 +0.14 0.08 5 AV6 -0.28 0.09 5 AV5 +0.12 0.13 7 AV4 -0.07 0.50 17 AV3 -0.02 0.12 6 AV2 -0.21 112 97 0.12 6 AV6 +0.02 0.25 11 AV5 -0.03 0.35 14 AV4 +0.00 0.41 15 AV3 +0.11 0.07 4 AV2 +0.11 112 99 0.15 7 AV6 -0.03 0.21 10 AV5 +0.00 0.41 15 AV4 -0.02 0.49 17 AV3 -0.05 0.13 7 AV2 -0.05 112 101 0.14 7 AV7 +0.00 0.41 15 AV4 +0.00 0.39 14 AV3 +0.00 0.13 7 AV2 -0.02 112 103 0.46 16 AV7 -0.02 0.25 11 AV6 +0.02 0.10 6 AV5 +0.00 0.09 5 AV3 -0.02 112 105 0.10 6 AV4 -0.10 112 119 0.09 5 AV6 +0.00 0.18 8 AV4 +0.03 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 77 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 22 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 112 121 0.19 9 AV4 +0.00 113 42 0.10 6 AV6 +0.03 0.14 7 AV4 +0.55 0.19 9 AV3 +0.07 113 48 0.13 7 AV6 -0.15 0.18 9 AV5 -0.05 0.15 7 AV4 +0.03 113 56 0.15 7 AV5 +0.00 113 66 0.10 5 AV6 +0.03 0.27 11 AV5 +0.02 0.16 8 AV4 +0.03 113 72 0.10 5 AV5 +0.12 113 74 0.17 8 AV6 +0.00 113 80 0.09 5 AV6 +0.09 0.10 5 AV3 -0.23 113 82 0.12 6 AV3 -0.07 113 88 0.36 14 AV6 +0.03 0.37 14 AV4 -0.02 0.18 9 AV3 -0.02 0.14 7 AV2 -0.14 113 90 0.14 7 AV8 +0.02 0.48 17 AV7 -0.02 0.36 14 AV6 -0.02 0.37 14 AV5 -0.03 0.08 5 AV4 -0.05 0.16 8 AV3 -0.07 113 92 0.11 6 AV7 +0.16 0.09 5 AV6 +0.00 0.10 6 AV5 -0.03 0.08 5 AV4 -0.16 0.11 6 AV3 -0.18 0.08 5 AV2 +0.48 113 94 0.06 4 AV7 -0.05 0.08 5 AV6 +0.02 0.33 13 AV5 +0.00 0.34 13 AV4 -0.02 0.34 13 AV3 -0.05 0.08 5 AV2 -0.16 113 96 0.30 12 AV4 -0.02 0.36 14 AV3 -0.05 0.23 10 AV2 -0.02 0.11 6 AV7 +0.02 0.20 9 AV6 +0.00 0.13 7 AV5 +0.00 113 98 0.07 4 AV5 -0.16 0.06 4 AV4 -0.19 0.19 9 AV3 -0.20 0.10 6 AV2 -0.05 113 100 0.15 7 AV2 -0.05 0.13 7 AV6 +0.00 113 102 0.09 5 AV4 -0.19 113 118 0.28 12 AV2 +0.00 0.16 8 AV4 +0.03 114 41 0.26 11 AV6 +0.00 0.19 9 AV4 -0.02 0.23 10 AV3 +0.02 114 43 0.12 6 AV7 +0.21 0.17 8 AV6 +0.00 0.17 8 AV5 +0.02 0.18 9 AV2 +0.02 114 57 0.17 8 AV5 +0.07 0.11 6 AV4 +0.24 114 65 0.18 9 AV5 -0.03 114 73 0.14 7 AV4 -0.19 0.13 7 AV2 +0.02 114 75 0.20 9 AV4 -0.02 0.21 10 AV3 -0.05 0.22 10 AV2 -0.05 0.19 9 AV1 -0.05 114 77 0.11 6 AV6 +0.16 0.14 7 AV4 -0.02 0.14 7 AV3 +0.00 114 79 0.12 6 AV6 +0.02 114 81 0.08 5 AV7 +0.00 0.07 4 AV6 +0.02 0.14 7 AV4 -0.07 114 83 0.31 12 AV7 -0.03 0.48 17 AV4 -0.02 0.22 10 AV3 -0.05 0.09 5 AV2 -0.02 114 87 0.41 15 AV7 +0.02 0.60 19 AV6 +0.00 0.50 17 AV2 +0.00 0.24 10 AV1 -0.02 114 89 0.09 5 AV8 +0.05 0.16 8 AV4 -0.21 0.42 15 AV3 -0.02 0.39 14 AV2 +0.00 0.18 8 AV1 -0.02 114 91 0.19 9 AV7 +0.09 0.25 11 AV6 +0.00 0.17 8 AV5 +0.00 0.47 16 AV4 -0.05 0.37 14 AV3 -0.05 0.09 5 AV2 -0.18 114 93 0.08 5 AV4 -0.02 0.19 9 AV3 -0.07 0.10 6 AV2 -0.05 114 95 0.37 14 AV5 +0.00 0.33 13 AV4 -0.02 0.33 13 AV3 -0.05 0.11 6 AV2 -0.16 114 97 0.05 4 AV5 +0.15 0.18 8 AV3 -0.05 114 101 0.14 7 AV5 +0.00 0.35 14 AV4 +0.00 0.44 16 AV3 -0.02 0.47 16 AV2 +0.00 0.14 7 AV1 -0.02 114 103 0.16 8 AV5 +0.00 0.12 6 AV2 +0.21 0.16 8 AV4 +0.00 114 123 0.06 4 AV5 +0.00 115 40 0.18 8 AV8 +0.05 0.08 5 AV4 +0.16 0.05 4 AV3 +0.12 115 56 0.09 5 AV7 -0.29 0.11 6 AV5 -0.21 0.11 6 AV6 -0.09 0.13 7 AV4 -0.16 115 58 0.10 6 AV5 -0.13 0.07 4 AV4 -0.14 0.08 5 AV3 -0.23 0.06 4 AV2 -0.02 115 60 0.14 7 AV5 +0.16 0.13 7 AV4 +0.03 0.27 11 AV3 +0.05 115 66 0.32 13 AV8 +0.07 0.36 14 AV6 +0.07 0.09 5 AV5 +0.30 0.16 8 AV4 +0.32 115 70 0.10 6 AV7 +0.09 0.51 17 AV6 +0.05 0.17 8 AV5 +0.23 0.10 6 AV4 +0.21 115 72 0.13 7 AV2 -0.18 0.11 6 AV1 -0.18 115 74 0.14 7 AV4 +0.00 0.10 6 AV3 +0.21 0.15 7 AV2 +0.00 0.06 4 AV1 +0.16 115 82 0.08 5 AV3 -0.05 115 84 0.19 9 AV8 +0.07 0.49 17 AV6 +0.00 0.52 17 AV5 -0.03 0.46 16 AV3 +0.02 0.37 14 AV2 +0.00 0.58 18 AV1 +0.00 115 88 0.17 8 AV8 +0.05 0.38 14 AV7 +0.02 0.32 13 AV6 +0.02 0.14 7 AV3 -0.05 0.09 5 AV2 +0.16 115 90 0.16 8 AV7 +0.02 0.46 16 AV6 +0.00 0.42 15 AV5 +0.00 0.19 9 AV3 -0.20 0.09 5 AV2 -0.16 115 92 0.14 7 AV7 +0.19 0.10 6 AV6 +0.00 0.19 9 AV5 +0.02 0.15 7 AV2 -0.02 115 94 0.15 7 AV7 +0.05 0.26 11 AV6 +0.00 0.17 8 AV3 -0.05 115 96 0.56 18 AV7 +0.05 0.36 14 AV2 +0.00 115 100 0.21 9 AV5 +0.12 0.12 6 AV2 -0.21 115 102 0.27 11 AV5 -0.03 0.39 15 AV4 -0.02 0.27 11 AV3 +0.00 0.28 12 AV2 +0.00 115 104 0.12 6 AV5 -0.03 115 112 0.13 7 AV3 +0.00 115 116 0.15 7 AV3 -0.02 115 122 0.10 6 AV3 +0.02 115 130 0.27 11 AV6 +0.02 0.08 5 AV5 +0.14 116 55 0.09 5 AV6 +0.22 0.18 8 AV5 +0.00 0.21 9 AV4 +0.05 116 57 0.21 9 AV5 +0.02 0.08 5 AV3 -0.48 116 59 0.08 5 AV5 +0.21 0.07 5 AV3 -0.05 116 61 0.12 6 AV5 +0.00 116 63 0.10 5 AV5 +0.05 0.12 6 AV3 +0.02 116 69 0.15 8 AV5 +0.00 0.14 7 AV4 +0.03 0.08 5 AV3 +0.00 0.06 4 AV2 -0.18 116 71 0.21 10 AV4 +0.00 116 73 0.10 5 AV4 +0.11 116 77 0.13 7 AV6 -0.12 116 79 0.10 6 AV4 +0.03 0.11 6 AV3 +0.07 0.11 6 AV2 +0.05 116 81 0.06 4 AV6 -0.02 0.10 6 AV4 -0.02 116 83 0.17 8 AV6 -0.02 0.21 10 AV5 -0.05 0.40 15 AV3 -0.02 0.29 12 AV2 -0.05 116 87 0.42 15 AV8 +0.02 0.46 16 AV5 +0.00 0.42 15 AV4 -0.02 0.21 9 AV3 -0.09 0.17 8 AV2 -0.02 0.06 4 AV1 -0.09 116 89 0.13 7 AV6 -0.02 0.23 10 AV4 -0.02 0.08 5 AV2 -0.23 116 91 0.10 6 AV7 +0.17 0.15 7 AV6 +0.05 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 78 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 23 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.24 10 AV5 -0.03 0.07 4 AV4 -0.02 0.12 6 AV3 -0.05 116 93 0.25 11 AV5 -0.03 0.26 11 AV4 -0.02 0.09 5 AV3 -0.25 116 95 0.40 15 AV5 -0.05 0.26 11 AV4 -0.02 0.08 5 AV3 +0.12 0.09 5 AV2 -0.14 116 97 0.08 5 AV5 +0.00 0.11 6 AV2 -0.02 0.07 4 AV1 +0.11 116 99 0.06 4 AV3 +0.00 117 78 0.14 7 AV3 -0.16 0.12 6 AV2 -0.02 117 82 0.12 6 AV5 -0.03 117 84 0.50 17 AV7 +0.02 0.17 8 AV4 +0.00 0.15 7 AV3 -0.05 0.45 16 AV2 -0.02 117 86 0.29 12 AV8 +0.00 0.55 18 AV7 -0.02 0.51 17 AV6 -0.05 0.42 15 AV4 +0.00 0.07 4 AV3 -0.18 0.10 6 AV2 -0.18 117 88 0.16 8 AV2 -0.02 0.19 9 AV6 -0.02 0.16 8 AV5 +0.00 0.08 5 AV4 -0.05 0.16 8 AV3 -0.05 117 90 0.13 7 AV8 +0.05 0.21 10 AV7 +0.00 0.33 13 AV6 +0.00 0.14 7 AV4 -0.05 117 92 0.09 5 AV7 +0.16 0.07 4 AV6 +0.56 0.13 7 AV5 -0.03 0.15 7 AV3 -0.05 0.20 9 AV2 -0.02 117 94 0.11 6 AV2 -0.05 117 98 0.16 8 AV7 +0.02 0.06 4 AV6 +0.23 0.11 6 AV5 +0.00 0.12 6 AV3 -0.20 0.08 5 AV2 -0.16 117 100 0.17 8 AV5 -0.06 0.22 10 AV3 -0.05 0.27 11 AV2 -0.05 118 79 0.08 5 AV2 -0.23 118 83 0.34 13 AV7 +0.00 0.58 18 AV6 -0.02 0.39 14 AV4 -0.05 0.16 8 AV3 -0.07 0.08 5 AV2 -0.02 118 87 0.12 6 AV8 +0.16 0.10 6 AV7 -0.02 0.33 13 AV6 -0.03 0.45 16 AV3 -0.02 0.40 15 AV2 -0.05 118 89 0.11 6 AV6 -0.02 0.39 14 AV5 +0.02 0.42 15 AV4 -0.05 0.16 8 AV3 -0.05 0.09 5 AV2 +0.00 118 91 0.38 14 AV7 +0.00 0.38 14 AV6 +0.00 0.30 12 AV5 +0.00 0.10 6 AV4 -0.02 0.10 6 AV3 -0.20 0.11 6 AV2 -0.05 118 93 0.35 13 AV7 +0.00 0.31 12 AV6 +0.00 0.22 10 AV4 -0.07 0.09 5 AV3 -0.05 0.27 11 AV2 -0.02 0.13 7 AV1 -0.05 118 95 0.08 5 AV1 +0.21 0.08 5 AV5 +0.15 0.33 13 AV4 -0.02 0.11 6 AV3 -0.02 0.23 10 AV2 -0.02 118 97 0.49 17 AV5 +0.00 0.09 5 AV2 -0.18 118 99 0.16 8 AV8 +0.07 0.63 19 AV7 +0.05 0.28 12 AV6 +0.02 0.19 9 AV5 +0.02 0.18 9 AV4 +0.03 0.13 7 AV3 -0.20 0.08 5 AV2 +0.09 118 101 0.13 7 AV7 -0.05 118 103 0.10 6 AV7 -0.14 0.13 7 AV5 -0.03 118 127 0.18 8 AV7 +0.02 119 78 0.09 5 AV7 +0.10 0.09 5 AV6 -0.12 0.11 6 AV4 +0.10 119 82 0.08 5 AV8 -0.29 0.28 12 AV7 +0.00 0.46 16 AV4 -0.05 0.15 8 AV3 -0.05 119 84 0.13 7 AV6 +0.07 0.28 12 AV4 -0.02 0.30 12 AV3 -0.05 0.17 8 AV1 +0.00 119 88 0.14 7 AV7 +0.00 0.35 14 AV6 +0.00 0.59 19 AV5 -0.03 0.16 8 AV3 -0.02 0.23 10 AV2 -0.05 0.07 4 AV4 -0.02 119 90 0.26 11 AV7 -0.02 0.30 12 AV6 +0.00 0.23 10 AV5 +0.00 0.13 7 AV3 -0.20 0.06 4 AV1 +0.14 119 92 0.18 9 AV7 -0.16 0.08 5 AV6 +0.44 0.12 6 AV5 -0.03 0.08 5 AV3 +0.16 119 94 0.12 6 AV2 -0.21 0.08 5 AV1 +0.34 119 96 0.11 6 AV1 -0.18 119 124 0.10 6 AV5 +0.00 120 61 0.12 7 AV7 +0.05 120 81 0.07 4 AV4 +0.08 120 83 0.08 5 AV6 -0.14 0.32 13 AV5 +0.00 0.29 12 AV4 -0.21 0.16 8 AV3 -0.05 120 85 0.32 13 AV8 +0.02 0.10 6 AV6 +0.00 0.10 6 AV2 -0.05 120 87 0.24 10 AV7 +0.02 0.46 16 AV6 +0.07 0.41 15 AV5 +0.00 0.34 13 AV4 -0.02 120 89 0.08 5 AV6 +0.18 0.08 5 AV5 +0.18 0.07 4 AV3 -0.18 0.13 7 AV4 -0.21 0.10 6 AV2 -0.23 0.09 5 AV8 -0.29 0.07 5 AV7 -0.16 120 91 0.33 13 AV2 -0.05 0.13 7 AV8 -0.02 0.40 15 AV7 +0.00 0.48 16 AV5 -0.03 120 93 0.08 5 AV3 -0.16 0.10 6 AV2 -0.05 120 97 0.09 5 AV3 -0.05 0.06 4 AV2 +0.23 120 105 0.12 6 AV5 +0.02 120 117 0.14 7 AV4 +0.05 120 119 0.13 7 AV7 +0.05 120 123 0.08 5 AV4 +0.00 0.15 7 AV2 +0.02 121 58 0.10 6 AV6 -0.02 0.10 6 AV5 -0.03 0.10 6 AV4 +0.03 121 62 0.19 9 AV6 +0.02 121 68 0.20 9 AV4 -0.05 121 74 0.17 8 AV4 -0.05 0.08 5 AV3 +0.14 0.12 6 AV2 -0.02 121 82 0.15 7 AV6 +0.00 0.20 9 AV5 -0.03 121 84 0.32 13 AV7 +0.02 0.33 13 AV5 -0.05 0.55 18 AV4 +0.00 0.13 7 AV3 -0.05 121 88 0.61 19 AV7 +0.00 0.63 19 AV6 +0.02 0.45 16 AV5 -0.03 0.18 8 AV4 -0.05 0.18 9 AV3 -0.02 0.15 8 AV2 -0.02 121 90 0.21 9 AV8 +0.02 0.36 14 AV7 +0.00 0.28 12 AV6 -0.02 0.42 15 AV5 +0.00 0.36 14 AV3 -0.02 0.09 5 AV2 +0.00 121 92 0.08 5 AV6 +0.07 0.17 8 AV3 -0.05 0.13 7 AV2 -0.02 0.08 5 AV1 +0.02 0.26 11 AV7 +0.16 121 94 0.14 7 AV4 -0.02 0.19 9 AV3 -0.07 0.08 5 AV2 -0.18 121 98 0.09 5 AV7 -0.05 121 100 0.30 12 AV7 +0.02 0.27 11 AV4 -0.05 0.11 6 AV2 -0.18 121 102 0.28 12 AV7 +0.02 0.21 9 AV5 -0.08 0.14 7 AV4 -0.09 0.13 7 AV3 -0.09 0.10 5 AV1 -0.02 122 73 0.18 9 AV4 -0.02 122 79 0.24 10 AV7 +0.00 0.48 17 AV6 +0.02 122 83 0.34 13 AV5 +0.02 0.51 17 AV3 +0.00 0.35 13 AV2 -0.02 0.16 8 AV1 -0.02 122 87 0.17 8 AV8 +0.05 0.12 6 AV7 +0.05 0.61 19 AV3 -0.02 0.28 12 AV2 -0.02 122 89 0.14 7 AV6 -0.02 0.26 11 AV5 +0.00 0.51 17 AV4 -0.02 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 79 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 24 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.18 8 AV3 -0.02 0.13 7 AV2 +0.00 122 91 0.08 5 AV8 +0.00 0.18 8 AV7 -0.17 0.10 6 AV6 -0.02 0.45 16 AV5 -0.05 0.10 5 AV3 -0.05 0.15 8 AV2 -0.05 0.10 6 AV1 +0.00 122 93 0.15 7 AV7 +0.18 0.18 8 AV5 -0.03 0.24 11 AV2 -0.02 122 95 0.10 5 AV5 -0.05 0.11 6 AV4 -0.21 0.25 11 AV3 -0.07 0.21 9 AV2 -0.05 122 97 0.10 6 AV5 +0.03 0.06 4 AV2 -0.02 0.06 4 AV6 +0.07 122 99 0.23 10 AV7 +0.18 0.10 5 AV5 +0.09 0.15 7 AV4 +0.03 0.12 6 AV2 -0.16 122 101 0.12 7 AV5 +0.05 0.16 8 AV4 +0.03 0.11 6 AV3 -0.21 122 103 0.18 8 AV6 +0.09 0.34 13 AV4 +0.14 0.46 16 AV2 +0.07 122 109 0.17 8 AV8 +0.07 0.14 7 AV7 +0.05 0.23 10 AV6 +0.09 0.11 6 AV4 +0.10 123 70 0.10 6 AV7 +0.21 0.11 6 AV5 -0.21 0.15 8 AV4 -0.02 123 72 0.07 4 AV5 +0.28 0.05 4 AV3 +0.23 0.12 6 AV2 +0.02 123 74 0.14 7 AV7 -0.07 0.20 9 AV6 -0.14 0.09 5 AV3 +0.00 123 78 0.10 5 AV3 +0.05 123 82 0.16 8 AV6 +0.05 0.10 6 AV4 +0.13 0.10 5 AV2 +0.05 123 84 0.12 6 AV8 +0.07 0.08 5 AV5 -0.05 0.56 18 AV4 -0.05 0.10 6 AV3 -0.18 123 86 0.23 10 AV6 -0.14 0.23 10 AV4 -0.02 0.44 16 AV3 -0.02 0.13 7 AV2 -0.23 123 88 0.16 8 AV8 +0.02 0.27 11 AV7 +0.00 0.11 6 AV6 +0.00 0.10 6 AV5 -0.24 0.09 5 AV3 -0.23 0.13 7 AV2 -0.23 123 90 0.14 7 AV7 +0.02 0.07 4 AV6 +0.21 0.18 9 AV3 -0.07 0.09 5 AV2 +0.32 123 92 0.14 7 AV7 +0.24 0.11 6 AV2 -0.02 123 94 0.18 8 AV5 +0.05 0.46 16 AV4 +0.00 0.20 9 AV3 -0.02 0.14 7 AV2 -0.02 123 98 0.33 13 AV7 +0.05 0.49 17 AV6 +0.07 0.45 16 AV4 +0.08 0.26 11 AV2 +0.05 124 55 0.09 5 AV5 -0.08 0.16 8 AV4 +0.00 0.08 5 AV3 -0.14 0.10 6 AV7 -0.12 0.09 5 AV6 +0.00 124 69 0.08 5 AV5 -0.21 124 71 0.17 8 AV4 +0.03 124 83 0.30 12 AV6 +0.00 0.44 16 AV5 -0.03 0.38 14 AV4 -0.05 0.16 8 AV3 +0.00 124 87 0.07 4 AV7 -0.05 0.11 6 AV6 +0.09 0.17 8 AV3 -0.07 0.35 13 AV2 +0.00 0.18 9 AV1 -0.02 124 89 0.23 10 AV6 +0.02 0.12 6 AV5 +0.14 0.10 6 AV3 -0.23 124 91 0.55 18 AV7 +0.02 0.33 13 AV6 +0.00 0.29 12 AV5 -0.05 0.07 4 AV2 -0.20 124 93 0.14 7 AV4 +0.18 0.10 6 AV3 -0.23 0.06 4 AV2 -0.16 0.06 4 AV1 +0.18 124 95 0.07 4 AV3 -0.27 0.11 6 AV2 -0.20 124 97 0.08 5 AV5 +0.16 124 99 0.14 7 AV7 +0.16 0.09 5 AV2 -0.20 125 54 0.15 7 AV6 +0.02 0.14 7 AV5 -0.03 0.18 8 AV4 +0.00 0.17 8 AV3 +0.19 125 56 0.08 5 AV3 +0.00 0.10 6 AV2 +0.00 125 62 0.24 10 AV5 -0.03 0.25 11 AV4 +0.05 0.08 5 AV2 +0.00 125 68 0.18 8 AV3 -0.05 0.13 7 AV2 -0.02 0.19 9 AV4 -0.05 0.15 7 AV5 -0.03 125 72 0.39 14 AV4 +0.03 0.28 12 AV3 +0.02 0.16 8 AV2 -0.02 0.08 5 AV1 -0.02 125 78 0.18 8 AV4 -0.02 125 80 0.15 8 AV4 +0.03 125 82 0.29 12 AV7 +0.05 0.10 6 AV6 +0.05 0.18 9 AV4 +0.18 125 84 0.10 6 AV6 +0.02 0.50 17 AV5 -0.05 0.28 12 AV3 -0.07 125 88 0.08 5 AV8 +0.05 0.37 14 AV6 +0.00 0.09 5 AV2 -0.05 125 90 0.14 7 AV8 +0.02 0.45 16 AV7 +0.00 0.39 14 AV6 -0.03 0.23 10 AV5 +0.00 0.46 16 AV4 -0.07 0.12 6 AV2 -0.02 0.06 4 AV1 +0.07 125 92 0.08 5 AV7 +0.23 0.09 5 AV3 -0.18 125 94 0.20 9 AV5 +0.02 0.13 7 AV4 -0.02 0.08 5 AV3 +0.16 0.12 6 AV2 -0.05 125 96 0.47 16 AV4 +0.05 0.21 9 AV1 +0.00 125 98 0.54 18 AV4 +0.03 0.11 6 AV3 -0.07 125 100 0.23 10 AV8 +0.07 0.19 9 AV7 +0.05 0.13 7 AV5 -0.05 0.22 10 AV4 -0.02 125 102 0.38 14 AV5 -0.05 0.30 12 AV3 -0.05 0.14 7 AV2 -0.05 0.09 5 AV1 -0.12 126 55 0.10 6 AV7 -0.14 0.40 15 AV6 -0.05 0.25 11 AV5 -0.08 0.07 5 AV4 +0.18 0.07 4 AV3 -0.02 126 69 0.21 9 AV4 +0.05 126 75 0.08 5 AV3 -0.18 126 77 0.15 7 AV3 -0.02 126 83 0.06 4 AV8 +0.12 0.07 4 AV7 +0.02 0.11 6 AV6 +0.03 0.35 13 AV5 -0.05 0.27 11 AV4 -0.05 0.10 6 AV3 -0.02 126 87 0.38 14 AV7 +0.02 0.17 8 AV6 +0.12 0.19 9 AV5 +0.00 0.47 16 AV4 +0.03 0.17 8 AV3 +0.00 0.19 9 AV2 -0.02 126 89 0.34 13 AV6 +0.00 0.24 10 AV5 +0.00 126 91 0.33 13 AV7 +0.02 0.23 10 AV5 +0.00 0.13 7 AV3 -0.20 126 93 0.10 5 AV6 +0.21 0.09 5 AV3 +0.00 0.18 9 AV2 -0.02 126 97 0.12 6 AV7 -0.02 126 99 0.07 5 AV4 -0.11 126 101 0.15 7 AV4 +0.05 0.17 8 AV3 +0.00 126 103 0.16 8 AV6 +0.00 0.15 8 AV4 -0.05 0.12 6 AV1 +0.14 126 105 0.19 9 AV4 -0.05 126 119 0.15 8 AV4 +0.00 127 66 0.07 4 AV6 +0.17 127 68 0.06 4 AV3 -0.05 0.05 4 AV2 +0.14 0.26 11 AV7 +0.02 0.34 13 AV6 +0.00 0.05 4 AV5 +0.18 0.15 7 AV4 -0.02 127 74 0.14 7 AV6 +0.09 0.11 6 AV4 -0.19 0.09 5 AV3 +0.12 127 82 0.07 4 AV6 +0.09 0.12 6 AV4 +0.23 0.07 4 AV3 +0.12 127 84 0.19 9 AV7 +0.05 0.43 15 AV6 +0.02 0.33 13 AV5 +0.00 0.48 16 AV4 +0.05 0.27 11 AV3 -0.02 0.32 13 AV2 +0.00 127 86 0.40 15 AV3 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 80 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 25 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.13 7 AV2 -0.18 0.25 11 AV6 +0.05 0.38 14 AV4 +0.00 127 88 0.08 5 AV7 -0.05 0.19 9 AV6 +0.05 0.19 9 AV2 -0.21 127 90 0.11 6 AV8 +0.05 0.19 9 AV7 +0.02 0.21 9 AV5 -0.03 0.32 13 AV4 -0.05 0.12 6 AV3 -0.20 0.17 8 AV1 -0.05 127 92 0.15 7 AV7 +0.05 0.09 5 AV3 -0.16 127 94 0.09 5 AV2 -0.23 127 96 0.13 7 AV5 +0.05 127 98 0.19 9 AV5 +0.05 0.15 7 AV4 +0.03 0.22 10 AV3 -0.02 127 100 0.08 5 AV5 +0.22 0.11 6 AV4 +0.00 127 102 0.27 11 AV7 +0.02 0.17 8 AV5 +0.02 0.40 15 AV4 -0.02 0.13 7 AV3 +0.00 0.22 10 AV2 -0.02 0.14 7 AV1 +0.00 127 104 0.10 6 AV7 +0.07 0.08 5 AV3 -0.05 127 106 0.31 12 AV4 +0.10 127 108 0.13 7 AV5 +0.00 0.12 6 AV4 +0.00 127 118 0.09 5 AV6 -0.02 128 53 0.12 6 AV7 +0.19 0.22 10 AV6 +0.00 0.47 16 AV4 -0.05 128 67 0.12 6 AV6 +0.09 0.08 5 AV5 -0.26 0.06 4 AV3 +0.14 128 71 0.18 8 AV8 -0.14 0.42 15 AV4 -0.02 0.11 6 AV2 -0.23 128 73 0.09 5 AV8 +0.28 0.10 6 AV6 +0.09 0.09 5 AV4 +0.03 128 75 0.09 5 AV5 +0.21 0.08 5 AV4 +0.18 128 77 0.08 5 AV3 +0.28 0.08 5 AV4 +0.18 128 79 0.14 7 AV2 +0.09 128 81 0.06 4 AV6 -0.23 0.13 7 AV4 +0.00 128 83 0.05 3 AV7 -0.26 0.08 5 AV6 +0.00 0.08 5 AV4 -0.35 0.11 6 AV3 +0.05 128 85 0.23 10 AV2 +0.00 0.17 8 AV6 +0.00 128 87 0.16 8 AV6 +0.16 0.16 8 AV5 +0.00 128 89 0.10 6 AV7 +0.02 0.05 4 AV6 -0.05 128 91 0.12 6 AV8 +0.05 0.36 14 AV7 +0.00 0.29 12 AV6 +0.00 0.20 9 AV5 -0.03 0.21 9 AV4 -0.05 0.18 9 AV3 -0.07 0.17 8 AV2 -0.21 128 95 0.07 4 AV3 -0.25 128 97 0.05 4 AV1 +0.11 0.10 5 AV5 +0.21 0.09 5 AV4 +0.00 0.11 6 AV3 -0.09 0.14 7 AV2 -0.02 128 99 0.14 7 AV7 +0.00 128 101 0.16 8 AV8 +0.02 0.46 16 AV7 +0.00 0.18 8 AV6 +0.00 0.23 10 AV4 -0.05 128 105 0.17 8 AV4 -0.02 0.23 10 AV3 +0.02 128 107 0.34 13 AV7 +0.02 128 109 0.20 9 AV5 +0.09 0.16 8 AV4 +0.08 0.13 7 AV3 -0.02 128 111 0.26 11 AV6 +0.00 0.34 13 AV5 -0.03 0.18 9 AV4 +0.03 0.20 9 AV3 -0.02 128 117 0.32 13 AV8 +0.07 0.44 16 AV7 +0.05 0.19 9 AV6 +0.02 0.10 6 AV5 -0.21 0.36 14 AV4 +0.00 129 66 0.17 8 AV8 +0.07 0.22 10 AV6 +0.00 0.20 9 AV5 -0.05 129 68 0.13 7 AV5 +0.00 0.54 18 AV3 -0.02 0.26 11 AV2 -0.02 129 72 0.13 7 AV2 -0.21 129 74 0.18 9 AV6 -0.14 129 76 0.14 7 AV4 -0.02 0.04 3 AV3 +0.02 129 78 0.30 12 AV6 -0.02 129 80 0.14 7 AV4 -0.07 129 82 0.12 6 AV4 +0.23 129 84 0.27 11 AV7 +0.02 0.10 6 AV6 +0.54 0.54 18 AV5 -0.08 0.39 14 AV4 -0.02 0.49 17 AV3 -0.02 129 86 0.58 18 AV7 +0.00 0.34 13 AV5 -0.03 129 88 0.14 7 AV7 +0.00 0.14 7 AV5 -0.03 0.15 7 AV4 -0.02 0.13 7 AV2 -0.21 129 90 0.13 7 AV8 +0.07 0.36 14 AV7 +0.02 0.21 10 AV6 -0.03 0.30 12 AV5 +0.03 0.50 17 AV4 +0.00 0.30 12 AV3 -0.02 129 92 0.22 10 AV7 +0.05 0.08 5 AV6 +0.21 0.14 7 AV5 +0.02 0.13 7 AV3 -0.09 0.12 6 AV2 -0.02 129 94 0.17 8 AV7 +0.05 0.18 8 AV4 +0.03 0.18 9 AV3 +0.00 0.13 7 AV2 -0.21 129 96 0.11 6 AV7 -0.16 0.15 8 AV6 +0.02 0.15 7 AV5 +0.00 0.11 6 AV4 +0.03 129 98 0.17 8 AV6 +0.00 129 102 0.41 15 AV5 -0.03 0.25 11 AV3 -0.02 0.17 8 AV2 -0.02 129 112 0.13 7 AV7 +0.20 0.20 9 AV6 +0.02 0.11 6 AV4 +0.03 130 67 0.38 14 AV7 +0.02 0.37 14 AV3 +0.00 0.12 6 AV2 +0.00 130 69 0.12 6 AV6 -0.02 0.35 13 AV4 +0.00 0.14 7 AV3 +0.00 0.32 13 AV2 -0.02 0.10 6 AV1 -0.02 130 73 0.12 6 AV4 +0.00 0.22 10 AV3 +0.02 130 83 0.15 7 AV5 +0.05 0.14 7 AV3 +0.05 0.09 5 AV2 +0.05 130 87 0.12 6 AV7 +0.02 0.23 10 AV6 +0.00 0.31 12 AV5 -0.03 130 89 0.31 12 AV6 +0.00 0.44 16 AV5 -0.05 0.41 15 AV4 -0.05 0.27 11 AV2 -0.05 130 91 0.14 7 AV7 +0.19 0.24 10 AV6 +0.02 0.52 17 AV5 -0.03 0.11 6 AV4 -0.02 0.18 8 AV2 -0.05 130 93 0.15 7 AV7 +0.02 0.18 9 AV4 +0.03 0.38 14 AV2 +0.00 130 95 0.49 17 AV8 +0.07 0.38 14 AV7 +0.02 0.09 5 AV5 +0.17 0.21 10 AV4 -0.07 0.23 10 AV3 +0.00 130 97 0.38 14 AV5 +0.08 0.27 11 AV4 +0.03 0.16 8 AV3 +0.05 130 99 0.24 10 AV4 +0.10 0.10 5 AV3 -0.07 0.10 5 AV2 -0.16 130 101 0.25 11 AV4 +0.05 0.08 5 AV1 -0.18 130 103 0.18 9 AV8 +0.05 0.48 16 AV7 +0.02 0.11 6 AV5 -0.03 0.34 13 AV4 +0.00 0.37 14 AV3 +0.00 0.35 13 AV2 +0.04 0.16 8 AV1 +0.00 130 113 0.13 7 AV4 -0.02 131 66 0.07 4 AV3 +0.14 131 68 0.28 11 AV6 +0.02 0.48 17 AV5 -0.03 0.35 14 AV4 -0.05 131 70 0.10 6 AV3 +0.23 0.35 13 AV8 +0.07 0.14 7 AV7 +0.07 0.43 15 AV6 +0.07 131 72 0.14 7 AV8 -0.07 0.14 7 AV6 +0.16 131 74 0.13 7 AV5 +0.07 0.13 7 AV4 +0.08 0.10 6 AV2 +0.21 131 78 0.08 5 AV6 -0.32 131 82 0.33 13 AV4 +0.36 0.12 6 AV3 -0.05 131 84 0.08 5 AV6 +0.09 131 86 0.35 13 AV8 +0.07 0.42 15 AV3 +0.02 0.17 8 AV2 +0.00 0.06 4 AV1 -0.05 131 88 0.07 4 AV7 -0.37 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 81 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 26 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.19 9 AV6 +0.02 0.10 6 AV5 +0.09 0.12 6 AV2 -0.21 131 90 0.14 7 AV7 +0.07 0.25 11 AV6 +0.02 0.17 8 AV3 -0.16 0.10 6 AV2 -0.05 0.37 14 AV1 +0.00 131 92 0.21 9 AV7 +0.28 0.19 9 AV6 +0.07 0.09 5 AV3 -0.25 131 94 0.13 7 AV2 -0.05 0.11 6 AV1 -0.02 0.22 10 AV5 +0.09 0.10 6 AV4 +0.08 0.29 12 AV3 +0.16 131 96 0.12 6 AV7 +0.27 0.14 7 AV5 +0.05 131 98 0.22 10 AV5 +0.05 0.17 8 AV4 +0.03 0.30 12 AV3 +0.00 131 100 0.08 5 AV2 -0.16 131 102 0.52 17 AV8 +0.05 0.25 11 AV2 +0.00 0.15 8 AV1 -0.05 131 104 0.41 15 AV6 +0.05 0.22 10 AV5 +0.02 0.18 9 AV4 +0.21 0.21 9 AV3 +0.07 132 69 0.09 5 AV7 +0.05 0.20 9 AV5 +0.02 0.12 6 AV4 +0.03 132 71 0.10 6 AV8 -0.17 0.10 6 AV5 -0.11 0.28 12 AV4 -0.02 132 73 0.11 6 AV7 +0.28 0.13 7 AV4 +0.29 0.11 6 AV2 -0.07 132 75 0.11 6 AV8 -0.28 0.07 4 AV5 -0.21 0.08 5 AV2 +0.02 132 77 0.42 15 AV6 +0.17 0.08 5 AV4 +0.18 132 79 0.09 5 AV6 -0.12 0.08 5 AV4 +0.00 132 81 0.40 15 AV6 -0.07 0.29 12 AV5 -0.08 0.17 8 AV4 -0.26 132 85 0.10 5 AV5 +0.00 0.16 8 AV3 -0.02 132 89 0.09 5 AV7 +0.07 0.20 9 AV6 +0.00 0.16 8 AV5 +0.02 0.35 13 AV4 +0.00 0.10 6 AV3 -0.18 132 91 0.08 5 AV8 -0.28 0.20 9 AV7 +0.02 0.43 15 AV6 +0.00 0.10 5 AV4 -0.19 0.11 6 AV3 -0.20 0.08 5 AV2 -0.23 132 93 0.13 7 AV5 -0.08 0.14 7 AV4 -0.05 0.18 9 AV7 +0.00 0.10 6 AV6 +0.21 132 95 0.18 9 AV7 +0.02 0.08 5 AV6 -0.09 0.28 12 AV5 -0.13 0.18 9 AV4 -0.12 0.25 11 AV3 -0.09 132 97 0.08 5 AV7 +0.05 0.10 6 AV5 +0.09 132 99 0.11 6 AV6 -0.14 0.16 8 AV4 +0.00 0.20 9 AV3 +0.02 0.10 6 AV2 -0.05 132 101 0.32 13 AV4 +0.03 0.24 10 AV3 +0.00 0.17 8 AV2 -0.02 133 62 0.15 7 AV7 -0.14 0.11 6 AV6 +0.19 133 70 0.18 8 AV8 +0.19 0.36 14 AV7 +0.02 0.28 12 AV5 -0.05 0.23 10 AV4 -0.14 133 72 0.50 17 AV5 -0.08 133 74 0.26 11 AV5 -0.05 0.11 6 AV4 -0.02 133 76 0.13 7 AV2 -0.23 133 78 0.17 8 AV6 -0.09 133 80 0.17 8 AV4 +0.00 133 82 0.13 7 AV6 +0.05 133 84 0.16 8 AV6 +0.00 133 86 0.07 4 AV6 +0.00 133 88 0.10 6 AV6 +0.05 0.18 9 AV5 +0.02 0.21 10 AV2 +0.02 133 90 0.41 15 AV7 +0.05 0.57 18 AV6 -0.02 0.57 18 AV5 +0.00 0.24 10 AV3 -0.18 0.22 10 AV2 -0.02 133 92 0.11 6 AV6 -0.02 0.38 14 AV5 +0.00 0.16 8 AV4 -0.02 0.11 6 AV2 +0.00 133 94 0.10 6 AV5 -0.24 0.08 5 AV3 -0.05 133 96 0.28 12 AV7 +0.05 0.31 12 AV6 +0.00 0.09 5 AV5 +0.15 0.09 5 AV4 -0.02 0.18 9 AV3 -0.23 0.12 6 AV2 -0.18 0.06 4 AV1 +0.25 133 102 0.16 8 AV3 +0.02 0.17 8 AV1 -0.05 134 69 0.12 6 AV5 -0.05 0.13 7 AV4 -0.16 0.13 7 AV2 -0.02 0.16 8 AV7 +0.02 134 71 0.22 10 AV5 -0.19 0.08 5 AV3 +0.30 0.15 8 AV8 +0.07 0.45 16 AV6 +0.18 134 73 0.11 6 AV8 -0.15 0.17 8 AV7 +0.02 0.14 7 AV6 -0.23 0.23 10 AV5 -0.11 134 75 0.17 8 AV8 -0.14 0.12 6 AV7 +0.17 0.15 7 AV4 +0.16 134 77 0.26 11 AV4 -0.02 134 79 0.23 10 AV6 +0.00 0.23 10 AV4 -0.05 134 81 0.15 8 AV7 +0.02 0.53 17 AV6 -0.02 0.31 12 AV5 -0.05 0.20 9 AV4 -0.19 134 83 0.09 5 AV8 +0.07 0.12 6 AV6 +0.05 0.25 11 AV4 -0.19 0.13 7 AV2 -0.05 134 87 0.09 5 AV5 +0.17 134 89 0.07 5 AV7 -0.43 0.16 8 AV6 -0.02 0.23 10 AV5 -0.05 0.27 11 AV4 -0.07 0.14 7 AV3 -0.07 0.16 8 AV2 +0.11 134 91 0.16 8 AV6 +0.00 0.13 7 AV3 -0.09 134 93 0.15 7 AV7 +0.00 0.16 8 AV4 -0.05 0.20 9 AV3 -0.05 134 95 0.22 10 AV5 -0.05 134 97 0.18 9 AV7 +0.02 135 70 0.19 9 AV8 +0.19 135 72 0.13 7 AV8 -0.19 135 74 0.20 9 AV6 +0.23 135 76 0.17 8 AV7 +0.07 0.16 8 AV6 +0.27 0.14 7 AV5 -0.03 0.11 6 AV4 -0.02 0.13 7 AV3 -0.02 135 78 0.13 7 AV4 +0.05 0.07 4 AV2 +0.20 135 80 0.10 6 AV8 -0.02 0.23 10 AV7 +0.19 0.29 12 AV6 +0.07 0.58 18 AV5 +0.05 0.17 8 AV4 +0.08 0.09 5 AV2 -0.23 135 82 0.32 13 AV2 +0.05 135 84 0.06 4 AV8 +0.14 0.14 7 AV7 +0.19 0.27 11 AV6 +0.05 0.21 9 AV5 +0.00 135 86 0.19 9 AV6 +0.02 0.10 6 AV5 +0.07 0.32 13 AV4 +0.03 0.20 9 AV3 +0.02 0.06 4 AV2 -0.09 135 90 0.50 17 AV8 +0.07 0.19 9 AV5 +0.02 0.15 7 AV3 -0.18 0.12 6 AV2 -0.05 0.07 4 AV1 -0.07 135 92 0.27 11 AV8 +0.10 0.49 17 AV6 +0.00 0.22 10 AV4 +0.05 0.14 7 AV3 +0.05 135 94 0.20 9 AV6 +0.07 0.13 7 AV5 +0.23 0.20 9 AV4 +0.03 0.27 11 AV3 +0.14 135 96 0.11 6 AV7 +0.11 0.25 11 AV6 +0.09 0.17 8 AV5 +0.30 0.17 8 AV4 +0.08 0.28 12 AV3 +0.00 0.20 9 AV2 -0.02 135 98 0.07 4 AV2 +0.14 136 73 0.16 8 AV8 -0.28 136 75 0.11 6 AV8 -0.12 0.12 6 AV1 -0.18 136 77 0.09 5 AV4 -0.16 0.07 4 AV2 +0.27 136 79 0.16 8 AV6 +0.23 136 83 0.12 6 AV8 +0.30 0.32 13 AV4 -0.28 0.12 6 AV3 -0.23 136 87 0.24 10 AV7 +0.05 0.21 10 AV6 -0.05 0.50 17 AV5 -0.08 0.12 6 AV3 -0.11 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 82 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:08:51 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 27 of 27 SL2 09/21 Bobbin AVB Wear 1-19%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 0.11 6 AV2 -0.14 0.07 4 AV1 -0.18 136 91 0.48 16 AV3 -0.05 0.29 12 AV2 -0.05 0.17 8 AV1 -0.05 136 93 0.11 6 AV7 +0.05 0.16 8 AV6 +0.07 0.47 16 AV5 -0.03 0.23 10 AV4 -0.02 136 95 0.13 7 AV7 +0.20 0.15 7 AV6 +0.07 0.10 6 AV4 +0.05 0.07 4 AV1 -0.05 136 99 0.16 8 AV7 +0.05 137 80 0.10 5 AV8 -0.17 137 82 0.31 12 AV8 +0.09 137 84 0.10 6 AV6 +0.07 137 86 0.07 4 AV7 +0.07 137 90 0.09 5 AV8 -0.28 0.52 17 AV7 +0.09 0.33 13 AV6 +0.05 0.17 8 AV5 +0.10 0.55 18 AV4 +0.11 0.10 5 AV3 -0.18 0.40 15 AV2 +0.00 0.12 6 AV1 +0.16 137 92 0.28 12 AV7 +0.23 0.19 9 AV5 +0.05 0.17 8 AV2 +0.14 138 85 0.27 11 AV8 -0.09 0.15 7 AV7 +0.02 0.29 12 AV5 -0.16 0.14 7 AV3 -0.05 0.11 6 AV2 +0.00 0.10 5 AV1 +0.16 138 91 0.16 8 AV7 +0.21 139 92 0.24 10 AV7 -0.14 Total Tubes : 2103 Total Records: 5653 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 83 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:09:52 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 1 of 3 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 54 9 0.66 20 AV6 -0.29 0.90 24 AV7 +0.20 56 17 0.74 21 AV6 -0.08 58 161 0.70 21 AV6 +0.21 60 159 0.68 20 AV2 +0.22 63 12 0.75 21 AV6 -0.03 63 158 1.06 26 AV2 +0.00 0.99 25 AV6 +0.00 65 14 0.86 23 AV6 -0.05 65 16 0.77 22 AV6 -0.05 65 130 0.77 22 AV6 +0.00 65 148 1.07 26 AV6 +0.00 65 158 0.86 23 AV2 -0.14 1.26 28 AV3 +0.30 1.52 30 AV6 -0.03 0.92 24 AV7 +0.20 66 13 0.65 20 AV3 +0.23 2.17 35 AV6 -0.03 66 19 0.91 24 AV6 -0.03 66 153 1.15 27 AV6 -0.03 67 14 1.07 26 AV6 -0.05 68 13 0.68 20 AV6 -0.05 68 157 0.85 23 AV6 -0.02 69 14 0.81 22 AV3 +0.12 0.80 22 AV6 -0.04 73 76 0.75 21 AV5 +0.00 74 65 0.99 25 AV6 +0.00 0.92 24 AV7 +0.02 76 63 1.56 30 AV6 +0.02 0.80 22 AV7 +0.05 76 69 1.38 29 AV4 +0.03 76 75 0.92 24 AV5 +0.02 0.74 21 AV6 +0.02 76 99 0.66 20 AV6 +0.00 78 75 0.73 21 AV5 +0.02 78 99 0.73 21 AV4 +0.06 1.66 31 AV5 +0.02 1.12 26 AV6 +0.02 79 66 0.71 21 AV4 +0.05 0.77 22 AV5 +0.02 79 96 0.71 21 AV5 +0.05 79 98 0.86 23 AV6 +0.05 79 110 0.83 23 AV5 +0.05 0.97 24 AV6 +0.02 0.72 21 AV7 +0.02 80 75 0.70 21 AV5 +0.00 80 77 0.71 21 AV5 +0.05 0.98 25 AV6 +0.05 81 54 0.64 20 AV6 +0.02 81 66 0.76 22 AV4 +0.03 1.37 29 AV5 +0.02 1.73 32 AV6 +0.00 0.77 22 AV7 +0.02 82 75 1.05 25 AV5 +0.02 0.97 24 AV6 +0.02 82 99 1.41 29 AV5 +0.05 1.19 27 AV6 +0.02 82 105 0.88 23 AV6 +0.00 0.77 22 AV7 +0.00 83 64 0.67 20 AV5 +0.02 83 66 1.16 27 AV5 +0.02 0.86 23 AV6 +0.00 83 76 0.76 22 AV6 +0.00 0.65 20 AV7 +0.05 83 78 1.32 28 AV5 +0.05 0.79 22 AV6 +0.02 0.93 24 AV7 +0.02 83 80 0.64 20 AV5 +0.02 0.85 23 AV6 +0.00 83 84 0.76 22 AV6 +0.05 83 106 0.81 22 AV5 +0.02 84 73 0.79 22 AV4 +0.05 0.64 20 AV5 +0.05 84 75 1.11 26 AV5 +0.00 0.82 22 AV6 +0.00 84 77 0.67 20 AV5 +0.05 1.13 26 AV6 +0.02 0.80 22 AV7 +0.00 84 103 0.69 20 AV5 +0.02 0.86 23 AV6 +0.00 84 105 0.91 24 AV5 +0.05 0.98 25 AV6 +0.02 85 76 0.67 20 AV5 +0.02 0.79 22 AV6 +0.05 85 98 0.74 21 AV5 +0.05 0.82 22 AV6 +0.02 85 100 0.77 22 AV5 +0.02 86 57 0.64 20 AV6 +0.02 0.77 22 AV7 +0.00 86 75 0.69 20 AV2 +0.05 1.24 27 AV5 +0.05 1.33 28 AV6 +0.02 86 77 0.68 20 AV6 +0.02 86 85 0.68 20 AV3 +0.02 1.05 25 AV4 +0.08 86 89 0.73 21 AV6 +0.02 86 97 0.72 21 AV3 +0.02 0.81 22 AV5 +0.02 86 99 0.67 20 AV5 +0.02 87 70 0.71 21 AV4 +0.00 1.67 31 AV5 +0.00 1.33 28 AV6 +0.02 87 76 1.07 26 AV4 +0.05 2.40 36 AV5 +0.02 0.67 20 AV6 +0.02 87 80 0.69 20 AV5 +0.00 87 82 0.70 21 AV5 +0.05 0.94 24 AV6 +0.02 0.80 22 AV7 +0.02 87 84 0.95 24 AV4 +0.05 0.94 24 AV5 +0.00 87 90 0.64 20 AV5 +0.02 87 96 0.67 20 AV5 +0.02 87 98 1.19 27 AV6 +0.00 1.01 25 AV7 +0.02 0.76 22 AV8 +0.00 87 106 0.78 22 AV7 +0.02 88 71 1.18 27 AV5 +0.05 2.18 35 AV6 +0.02 0.90 24 AV7 +0.02 88 85 0.86 23 AV5 +0.05 0.77 22 AV7 +0.00 88 95 1.09 26 AV5 +0.02 0.85 23 AV6 +0.02 1.13 26 AV7 +0.00 88 97 1.30 28 AV5 +0.05 1.17 27 AV6 +0.02 0.80 22 AV3 +0.00 88 99 0.94 24 AV4 +0.05 2.15 34 AV5 +0.05 1.22 27 AV6 +0.05 88 103 1.26 28 AV5 +0.00 1.53 30 AV6 +0.02 89 70 0.84 23 AV6 +0.02 0.69 20 AV7 +0.02 89 72 0.89 23 AV5 +0.02 0.68 20 AV7 +0.02 89 74 0.77 22 AV6 +0.02 1.13 26 AV7 +0.00 89 82 1.20 27 AV3 +0.02 1.49 30 AV5 +0.00 1.02 25 AV6 +0.02 89 84 1.25 28 AV4 +0.00 1.52 30 AV5 +0.00 0.84 23 AV6 +0.00 89 90 0.77 22 AV4 +0.05 0.91 24 AV5 +0.02 89 98 0.68 20 AV2 +0.02 90 65 0.71 21 AV6 +0.02 90 73 0.74 21 AV5 +0.02 0.65 20 AV6 +0.02 90 77 1.12 26 AV5 +0.07 2.85 38 AV6 +0.02 1.62 31 AV7 +0.02 90 83 0.68 20 AV4 +0.08 0.86 23 AV5 +0.02 90 97 1.59 31 AV6 +0.02 1.04 25 AV7 +0.02 0.80 22 AV8 +0.02 90 99 0.75 21 AV6 +0.02 90 103 1.15 27 AV6 +0.07 91 66 1.14 26 AV6 -0.02 1.32 28 AV5 -0.03 0.83 23 AV4 +0.00 91 78 1.12 26 AV7 -0.02 91 80 0.69 20 AV6 +0.00 91 82 0.69 20 AV5 -0.08 91 86 0.65 20 AV3 +0.02 91 92 0.81 22 AV7 +0.02 0.92 24 AV6 +0.05 1.75 32 AV5 +0.02 91 98 0.82 22 AV6 +0.00 0.65 20 AV5 +0.02 0.77 22 AV7 +0.00 92 65 0.67 20 AV7 +0.02 0.69 20 AV6 +0.00 92 77 1.61 31 AV7 +0.00 2.99 39 AV6 +0.05 1.43 29 AV5 +0.05 0.79 22 AV4 +0.05 92 79 1.16 27 AV6 +0.05 1.29 28 AV5 +0.05 0.86 23 AV4 +0.05 92 81 0.89 23 AV7 -0.05 0.79 22 AV6 -0.02 92 83 1.77 32 AV5 -0.03 92 85 1.38 29 AV7 -0.02 1.82 32 AV6 +0.02 0.89 23 AV5 +0.02 92 93 0.64 20 AV5 +0.02 92 95 0.64 20 AV6 +0.02 0.79 22 AV5 +0.02 0.90 24 AV4 +0.03 92 99 1.51 30 AV6 +0.02 2.15 35 AV5 +0.02 92 103 0.65 20 AV5 +0.02 0.88 23 AV4 +0.03 93 64 0.86 23 AV6 +0.00 93 72 0.77 22 AV5 -0.03 93 82 0.65 20 AV6 -0.03 0.98 25 AV5 -0.05 93 84 0.92 24 AV6 -0.02 1.31 28 AV5 -0.05 1.29 28 AV4 +0.00 93 86 0.90 24 AV7 -0.05 0.73 21 AV6 +0.00 0.78 22 AV5 +0.00 0.74 21 AV4 +0.03 93 92 0.86 23 AV5 -0.03 93 94 0.68 20 AV7 +0.00 1.01 25 AV6 +0.02 0.98 25 AV5 +0.05 93 98 2.43 36 AV7 +0.00 2.47 36 AV6 -0.02 1.64 31 AV5 -0.03 0.84 23 AV4 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 84 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:09:52 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 2 of 3 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 93 100 0.89 23 AV4 +0.00 94 67 0.72 21 AV6 +0.00 94 69 0.78 22 AV4 +0.00 94 71 0.71 21 AV6 +0.05 94 77 1.42 29 AV6 +0.00 0.90 24 AV5 -0.03 94 79 0.65 20 AV6 +0.03 94 81 0.83 23 AV6 +0.00 0.64 20 AV5 -0.03 0.68 20 AV4 -0.05 94 83 1.29 28 AV6 +0.02 2.46 36 AV5 +0.05 1.84 33 AV4 +0.13 1.29 28 AV3 +0.05 94 85 0.67 20 AV5 -0.03 1.42 29 AV4 -0.05 0.85 23 AV3 -0.02 0.75 21 AV2 +0.00 94 87 0.97 25 AV5 +0.02 0.93 24 AV4 +0.08 0.76 22 AV3 +0.02 94 91 0.93 24 AV6 +0.00 94 95 0.83 23 AV3 +0.00 1.13 26 AV2 +0.00 0.71 21 AV4 -0.02 94 99 1.13 26 AV5 +0.05 0.74 21 AV4 +0.05 95 64 0.78 22 AV7 +0.03 95 76 0.73 21 AV5 -0.03 95 78 0.75 21 AV6 +0.05 0.94 24 AV5 +0.02 0.64 20 AV3 +0.02 95 80 0.81 22 AV7 +0.00 1.14 26 AV6 +0.02 1.35 29 AV5 +0.05 0.81 22 AV4 +0.05 95 84 1.62 31 AV5 +0.05 1.51 30 AV4 +0.08 0.92 24 AV3 +0.05 95 86 1.00 25 AV7 -0.02 0.76 22 AV6 +0.02 1.67 31 AV5 +0.05 1.24 28 AV4 +0.05 0.72 21 AV3 +0.02 95 88 1.15 27 AV7 +0.00 0.70 21 AV6 +0.02 95 90 0.64 20 AV5 +0.00 95 92 0.80 22 AV5 +0.02 95 96 1.33 28 AV6 +0.00 1.50 30 AV5 +0.02 0.81 22 AV4 +0.05 95 98 0.68 20 AV3 +0.02 95 104 2.56 37 AV7 +0.02 1.28 28 AV6 +0.00 0.85 23 AV5 +0.00 96 71 0.64 20 AV8 +0.02 1.85 33 AV7 +0.00 0.95 24 AV6 +0.00 96 77 0.87 23 AV3 +0.05 96 79 0.68 20 AV7 +0.00 1.52 30 AV6 +0.05 1.12 26 AV5 +0.05 0.89 23 AV4 +0.05 96 83 0.77 22 AV4 +0.00 96 87 0.98 25 AV6 +0.00 96 89 0.80 22 AV6 +0.00 96 93 0.68 20 AV7 +0.02 1.28 28 AV6 +0.00 1.66 31 AV5 +0.00 96 97 0.97 24 AV6 +0.00 0.86 23 AV5 -0.05 96 105 0.76 22 AV3 +0.00 96 107 0.66 20 AV7 +0.02 0.84 23 AV6 +0.00 97 66 1.61 31 AV7 +0.02 1.55 30 AV6 -0.03 1.09 26 AV5 -0.03 97 76 0.91 24 AV7 +0.00 1.95 33 AV6 +0.00 1.26 28 AV4 +0.03 1.43 29 AV3 +0.00 97 84 0.76 21 AV6 +0.02 0.99 25 AV5 +0.00 97 86 1.50 30 AV7 -0.02 0.78 22 AV5 +0.00 0.97 24 AV4 +0.00 0.84 23 AV3 -0.02 97 92 0.71 21 AV6 -0.05 0.92 24 AV5 +0.00 1.71 32 AV4 -0.02 0.91 24 AV3 +0.00 97 96 0.75 21 AV7 -0.02 1.25 28 AV6 +0.00 97 98 0.68 20 AV6 +0.02 0.94 24 AV5 -0.03 97 104 0.71 21 AV6 +0.02 0.73 21 AV5 -0.03 0.74 21 AV4 +0.00 98 67 0.79 22 AV3 +0.05 98 75 1.78 32 AV7 -0.02 98 85 0.76 22 AV7 -0.02 1.77 32 AV4 +0.00 1.79 32 AV3 +0.00 1.25 28 AV2 +0.00 98 87 1.13 26 AV7 -0.02 1.90 33 AV6 +0.00 98 91 1.43 29 AV4 +0.00 98 95 0.72 21 AV7 +0.00 98 97 0.71 21 AV4 +0.00 98 103 0.70 21 AV3 +0.02 98 107 0.73 21 AV7 +0.00 1.06 26 AV6 +0.00 99 64 2.06 34 AV7 +0.02 1.72 32 AV6 +0.02 0.95 24 AV5 +0.00 99 66 1.36 29 AV6 +0.00 2.49 36 AV5 +0.00 1.36 29 AV4 +0.00 99 74 0.71 21 AV7 +0.00 1.66 31 AV6 +0.00 1.83 32 AV5 +0.00 99 76 1.02 25 AV6 +0.00 99 82 1.16 27 AV5 -0.08 0.95 24 AV3 -0.02 99 84 1.49 30 AV6 +0.00 1.96 33 AV5 -0.03 1.04 25 AV4 +0.03 99 86 2.22 35 AV7 -0.02 0.81 22 AV6 -0.02 0.87 23 AV4 +0.05 1.04 25 AV3 +0.02 0.72 21 AV2 -0.05 99 92 1.82 32 AV6 +0.05 2.24 35 AV5 +0.05 1.78 32 AV4 +0.05 1.56 30 AV3 +0.05 0.76 22 AV2 +0.02 0.82 22 AV7 +0.05 99 96 1.01 25 AV6 +0.02 1.77 32 AV5 +0.00 1.31 28 AV4 +0.00 99 98 0.84 23 AV3 +0.05 99 104 0.66 20 AV4 -0.05 100 71 0.78 22 AV7 +0.02 100 77 2.09 34 AV7 +0.00 2.64 37 AV6 +0.02 1.18 27 AV5 +0.07 1.06 26 AV3 +0.05 100 85 0.96 24 AV7 -0.02 0.68 20 AV6 +0.00 0.68 20 AV4 +0.00 100 87 1.02 25 AV6 +0.00 1.36 29 AV5 +0.00 100 93 0.74 21 AV5 +0.00 101 64 0.93 24 AV7 +0.05 0.76 22 AV6 +0.02 101 74 0.83 23 AV3 +0.02 101 76 0.91 24 AV4 +0.03 101 86 0.75 21 AV7 -0.05 1.38 29 AV5 -0.03 0.79 22 AV4 -0.02 101 90 0.89 23 AV7 +0.02 101 98 0.67 20 AV4 +0.06 0.76 22 AV3 +0.02 101 104 1.26 28 AV5 -0.03 1.38 29 AV4 +0.00 102 75 1.01 25 AV7 +0.00 102 81 0.76 22 AV6 +0.00 0.81 22 AV5 +0.02 0.64 20 AV3 +0.00 102 83 1.41 29 AV5 -0.03 1.01 25 AV4 -0.05 102 85 2.33 36 AV7 -0.02 2.59 37 AV6 +0.00 1.09 26 AV3 +0.02 102 87 2.49 36 AV7 +0.00 2.89 38 AV6 -0.03 1.62 31 AV5 -0.03 102 89 1.32 28 AV6 -0.03 1.46 30 AV5 -0.03 0.68 20 AV4 +0.00 1.55 30 AV3 -0.02 0.97 24 AV2 +0.00 102 91 2.16 35 AV7 +0.05 1.30 28 AV6 -0.05 1.39 29 AV5 -0.05 102 97 0.78 22 AV7 +0.02 1.00 25 AV6 -0.02 1.01 25 AV4 -0.02 0.73 21 AV5 +0.00 103 84 0.68 20 AV7 -0.02 1.03 25 AV5 -0.03 1.16 27 AV3 +0.00 103 86 1.24 28 AV5 +0.00 1.27 28 AV4 +0.00 104 83 0.80 22 AV5 -0.05 1.06 26 AV4 -0.02 104 87 0.81 22 AV5 -0.03 104 91 0.87 23 AV5 +0.02 0.73 21 AV4 +0.03 1.18 27 AV3 +0.00 104 97 1.09 26 AV4 -0.05 105 72 0.64 20 AV4 +0.03 0.69 20 AV3 +0.02 105 86 0.77 22 AV7 -0.05 0.81 22 AV6 -0.02 1.44 29 AV5 -0.06 1.42 29 AV4 -0.02 105 96 1.10 26 AV5 +0.00 106 83 0.83 23 AV4 +0.00 0.66 20 AV3 +0.00 106 85 1.77 32 AV7 +0.00 2.20 35 AV6 +0.00 0.94 24 AV5 -0.03 1.70 31 AV3 +0.00 0.70 21 AV2 +0.00 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 85 of 86 L-2022-048

Framatome Inc.

9/13/2021 9:09:52 AM Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B Page 3 of 3 SL2 09/21 Bobbin AVB Wear 20-39%

ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION ROW COL VOLTS %TW LOCATION 106 87 0.73 21 AV3 +0.00 106 91 0.76 21 AV5 -0.03 106 97 1.07 26 AV3 +0.00 0.66 20 AV2 +0.00 107 78 1.12 26 AV6 +0.02 107 84 0.65 20 AV7 -0.02 1.18 27 AV6 -0.05 1.55 30 AV5 -0.08 0.97 24 AV4 +0.00 107 92 1.27 28 AV4 +0.03 1.57 30 AV3 +0.05 0.68 20 AV2 +0.00 107 98 1.10 26 AV5 -0.03 107 100 0.65 20 AV3 -0.02 108 83 0.72 21 AV7 -0.02 1.75 32 AV6 -0.02 0.94 24 AV5 -0.03 108 91 1.37 29 AV5 +0.05 1.89 33 AV4 +0.05 108 95 0.71 21 AV3 +0.05 108 99 0.66 20 AV7 +0.02 2.24 35 AV6 +0.00 0.71 21 AV4 +0.00 109 68 0.73 21 AV6 +0.03 109 72 0.88 23 AV5 -0.03 109 84 0.88 23 AV7 +0.00 1.67 31 AV5 -0.05 1.47 30 AV4 -0.02 109 86 0.79 22 AV7 +0.00 1.21 27 AV6 -0.02 1.36 29 AV5 -0.03 1.99 34 AV4 -0.05 109 98 0.89 23 AV4 +0.06 1.10 26 AV3 +0.05 0.70 21 AV2 +0.00 109 100 0.92 24 AV6 +0.05 110 83 0.89 23 AV5 +0.00 0.95 24 AV4 -0.02 110 85 1.70 31 AV7 +0.00 1.83 32 AV5 -0.03 0.90 24 AV4 -0.02 0.78 22 AV3 -0.02 110 87 0.83 23 AV6 +0.02 0.68 20 AV3 -0.02 110 95 1.03 25 AV4 -0.05 110 101 0.70 21 AV6 +0.02 1.19 27 AV5 +0.00 111 84 0.89 23 AV5 -0.05 0.90 24 AV4 +0.00 0.88 23 AV3 -0.02 111 86 0.94 24 AV7 -0.02 2.09 34 AV6 +0.02 1.10 26 AV4 +0.00 111 94 1.06 26 AV5 +0.00 111 102 1.25 28 AV7 +0.00 1.18 27 AV6 -0.02 2.57 37 AV5 -0.05 0.64 20 AV3 +0.00 113 88 0.92 24 AV5 +0.00 114 83 1.02 25 AV6 +0.00 1.85 33 AV5 +0.00 114 87 0.96 24 AV5 +0.00 0.86 23 AV4 +0.03 0.98 25 AV3 +0.02 114 89 0.95 24 AV7 +0.00 2.25 35 AV6 -0.02 0.85 23 AV5 +0.00 115 66 0.73 21 AV7 +0.07 115 82 0.68 20 AV5 +0.02 115 84 1.55 30 AV7 +0.00 1.02 25 AV4 +0.03 115 88 0.87 23 AV5 -0.03 0.65 20 AV4 -0.02 115 94 0.93 24 AV5 +0.02 115 96 0.70 21 AV6 +0.05 1.10 26 AV4 +0.03 0.78 22 AV3 +0.00 116 83 0.89 23 AV4 +0.00 116 87 1.26 28 AV7 -0.02 0.80 22 AV6 +0.00 117 84 0.73 21 AV6 -0.02 0.66 20 AV5 -0.03 117 86 1.89 33 AV5 +0.00 117 90 0.65 20 AV5 -0.03 118 83 1.70 32 AV5 -0.03 118 87 1.12 26 AV5 +0.00 1.05 25 AV4 -0.02 119 82 0.68 20 AV6 +0.00 1.10 26 AV5 -0.03 119 84 0.72 21 AV2 -0.02 120 85 1.32 28 AV7 -0.02 1.34 28 AV5 -0.03 0.91 24 AV4 -0.02 0.87 23 AV3 +0.00 120 91 0.64 20 AV6 -0.05 121 84 1.01 25 AV6 +0.00 121 90 1.00 25 AV4 -0.02 121 100 1.03 25 AV6 +0.00 2.68 37 AV5 -0.03 122 83 0.96 24 AV4 +0.03 122 87 1.22 27 AV6 +0.00 1.63 31 AV5 -0.03 1.80 32 AV4 -0.02 122 103 0.72 21 AV3 +0.07 123 84 0.69 20 AV7 +0.00 0.83 23 AV6 -0.02 123 86 0.78 22 AV5 +0.02 123 90 0.87 23 AV5 +0.00 1.57 30 AV4 -0.02 123 98 0.86 23 AV3 +0.07 124 87 0.96 24 AV5 -0.03 0.76 22 AV4 -0.05 125 84 0.69 20 AV4 -0.02 125 86 1.93 33 AV6 +0.00 0.93 24 AV5 -0.03 1.41 29 AV4 -0.02 0.79 22 AV3 +0.00 125 96 0.67 20 AV3 +0.02 125 98 1.29 28 AV6 +0.00 2.40 36 AV5 +0.02 125 102 0.83 23 AV4 -0.05 126 103 0.79 22 AV5 -0.03 127 86 2.40 36 AV5 +0.00 128 53 1.57 30 AV5 -0.03 128 85 1.45 29 AV5 +0.00 0.89 23 AV3 +0.00 129 68 1.12 26 AV4 -0.02 129 86 0.79 22 AV6 -0.02 0.86 23 AV4 -0.02 129 102 0.94 24 AV4 -0.02 130 67 1.67 31 AV5 +0.02 1.14 26 AV4 +0.05 130 69 0.65 20 AV5 -0.03 131 70 1.00 25 AV5 +0.07 131 86 1.68 31 AV7 +0.05 1.15 27 AV6 +0.07 0.72 21 AV5 +0.05 1.13 26 AV4 +0.05 131 90 0.69 20 AV4 +0.00 131 102 0.99 25 AV7 +0.05 1.33 28 AV6 +0.05 0.81 22 AV4 +0.03 132 71 0.75 21 AV7 +0.02 1.99 34 AV6 +0.00 132 73 1.15 27 AV5 +0.00 132 91 0.96 24 AV5 +0.05 133 70 0.90 24 AV6 -0.02 133 90 1.22 27 AV8 +0.05 0.65 20 AV4 -0.02 133 92 0.87 23 AV7 +0.00 133 102 0.68 20 AV5 +0.09 1.32 28 AV4 +0.10 0.69 20 AV2 +0.02 134 71 0.71 21 AV7 +0.02 134 91 3.13 39 AV8 +0.09 0.67 20 AV7 +0.00 1.04 25 AV5 -0.05 0.73 21 AV4 -0.07 135 82 0.66 20 AV8 +0.09 0.75 21 AV7 +0.07 0.92 24 AV6 +0.07 0.82 22 AV5 +0.07 2.51 37 AV4 +0.13 1.59 31 AV3 +0.05 135 84 0.96 24 AV4 +0.00 135 90 1.23 27 AV7 +0.05 2.69 37 AV6 -0.02 1.05 25 AV4 -0.02 135 92 1.76 32 AV7 +0.02 1.53 30 AV5 +0.05 136 83 0.66 20 AV6 +0.00 136 87 0.78 22 AV4 -0.07 136 91 0.70 21 AV8 +0.10 2.94 39 AV7 +0.07 0.65 20 AV6 +0.05 0.75 21 AV5 +0.02 2.61 37 AV4 +0.03 138 85 0.86 23 AV6 -0.05 1.10 26 AV4 -0.12 Total Tubes : 301 Total Records: 611 Appendix F - Wear at AVB (below 40%)

ENCLOSURE Page 86 of 86 L-2022-048