L-2019-064, Refueling Outage SL2-24 Steam Generator Tube Inspection Report

From kanterella
(Redirected from ML19081A146)
Jump to navigation Jump to search

Refueling Outage SL2-24 Steam Generator Tube Inspection Report
ML19081A146
Person / Time
Site: Saint Lucie 
Issue date: 03/22/2019
From: Snyder M
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2019-064
Download: ML19081A146 (90)


Text

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re: St. Lucie Unit 2 Docket No. 50-389 Refueling Outage SL2-24 Steam Generator Tube Inspection Report MAR 2 2 2019 L-2019-064 10 CFR 50.55a 10 CFR 50.36 Attached is the St. Lucie Unit 2 Technical Specification 6.9.1.12 steam generator tube inspection report for the fall2018 refueling outage (SL2-24). This submittal was made within 180 days after the initial entry into hot shutdown following the completion of the steam generator inspection that was performed in accordance with TS 6.8.4.1, Steam Generator (SG) Program.

Please contact Ken Frehafer at (772) 467-7748 should you have any questions regarding this submittal.

Sincerely,

/f~v~

J\\!Iichael]. Snyder Licensing Manager St. Lucie Plant.

MJS/K\\X!F

Enclosure:

St. Lucie Unit 2 SL2-24 Steam Generator Tube Inspection Report cc:

USNRC Regional Administrator, Region II USNRC Senior Resident Inspector, St. Lucie Nuclear Plant Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957

Enclosure SL2-24 Steam Generator Tube Inspection Report

==

Introduction:==

L-2019-064 Enclosure Page 1 of 89 The enclosed Steam Generator (SG) Tube Inspection Report for the St. Lucie Unit 2 recirculating steam generators (RSGs) is submitted for the inspection performed during refueling outage 24 (hereafter referred to as the SL2-24 inspection/outage), as required by Technical Specification section 6.9.1.12. The SL2-24 inspection was performed in accordance with Technical Specification 6.8.4.1.1, and was the sixth inspection of the RSGs in the first sequential period.

References to prior SG Tube Inspection Reports for the RSGs are tabulated in Appendix A along with a list of acronyms and abbreviations used in this report.

At unit shutdown for the SL2-24 inspection, the RSGs had operated for approximately 9.1 EFPY (1 09.1 EFPM) since installation in December 2007. This included operation for approximately 1.40 EFPY (16.8 EFPM) during the fuel cycle (cycle 23) leading-up to the SL2-24 inspection. Per the St. Lucie Unit 2 Technical Specification section 6.8.4.1.1.d, the first sequential period is 144 EFPMs. Initial entry into Hot Shutdown following completion of the SL2-24 inspection was made on September 27, 2018.

St. Lucie Unit 2 is a Combustion Engineering 2-loop PWR with Model 86/19TI RSGs manufactured by AREVA. The RSGs were fabricated using thermally-treated lnconel 690 tubing.

Each RSG contains 8,999 U-tubes; each tube has a nominal OD of 0.75" and a nominal wall thickness of 0.0429". The tubes have a tri-pitch arrangement and are supported by broached, stainless steel tube support plates (TSPs). The inspection of the RSGs during the SL2-24 outage meets the requirements of the St. Lucie Unit 2 Technical Specifications and the EPRI SGMP: PWR Steam Generator Examination Guidelines, Revision 8.

A. Scope of Inspections Performed on each SG Primary-side:

  • 1 00% full-length bobbin probe examination of all active tubes.

Array probe examination at TTS locations of all tubes in hot and cold leg tube expansion transitions of peripheral high-flow regions, and low-row tubes along the tube-free lane.

(Peripheral tubes in each RSG span the 2 outermost tubes (of each row) exposed to the annulus, and all tubes in Rows 1-4 along the tube-free lane.) The exam extent was+/- 3.0" from the TTS.

  • Array probe examination of all tubes with previously-identified PLP Indications based on +Point' exams, and adjacent tubes.
  • 30% sample of tight-radius U-bends of Rows 1 & 2 using the +Point' probe. The exam extent was from the uppermost TSP on the hotleg to the uppermost TSP on the cold leg.
  • Diagnostic +Point' examination at special interest locations as required based on the results of the bobbin coil and array coil data.
  • Selected wear indications were profiled with line-by-line sizing to provide additional information for condition monitoring and operational assessment purposes.
  • Visual inspection of all installed tube plugs in each RSG.
  • Visual inspection of all cladded surfaces of the channel-head of each SG for degradation.

Secondary-side:

  • Visual inspection of the feedwater ring and supports in both RSGs.

L-2019-064 Enclosure Page 2 of 89

  • No upper tube bundle flush, sludge lancing or foreign object search and retrieval (FOSAR) was scheduled during the SL2-24 inspection outage.

B. Active degradation mechanisms found Wear at tube support locations was the only active (existing) degradation mechanism identified during the SL2-24 RSG inspection. This degradation mechanism was found on tubes at the following tube support locations:

  • Wear at anti-vibration bar (AVB) contact points
  • Wear at V-shaped support pad (V-SSP) contact points 1
  • Wear at tube support plate (TSP) contact points No degradation was identified that was due to foreign objects or to corrosion degradation mechanisms. No evidence of tube-to-tube wear was found.

C. Nondestructive examination techniques utilized for each degradation mechanism Table 1 is a list of the EPRI Examination Technique Specification Sheets (ETSS) used for degradation detection/sizing during the SL2-24 inspection.

Table 1 NDE Degradation Mechanism ETSS Technique Location/Description Status Type detection/sizing Wear at AVB supports (extended 1

Bobbin for detection of V-shaped support Existing Volumetric 1-96041. 1 Rev 5 pad and V-shaped support bar wear)

Wear at AVB and TSP supports 2

Bobbin (extended for detection of Existing Volumetric 96004.1 Rev. 13 V-shaped support pad and V-shaped support bar wear) 3 Bobbin Wear at AVB and TSP supports Existing Volumetric 96004.3 Rev. 13 4

Bobbin Foreign Object Wear (PLP)

Potential Volumetric 27091.2 Rev. 2 5

Bobbin 13091.1 Rev. 0 Tube-to-tube Wear Potential Volumetric 13901.1 Rev 1 6

+Point' 7

Arral 11956.3 Rev 2, Wear at broached support plates Existing Volumetric 11956.4 Rev 2 8

+Point' 96910.1 Rev. 11 9

+Point' Wear at AVB supports (extended Existing Volumetric 10908.4, Rev. 1 for detection of V-SSP) 10

+Point' Volumetric Freespan Not Potential Volumetric 21998.1 Rev.4 1 Wear at V-SSPs is also commonly called "appui" wear. Clarification of V-SSP Wear is documented in the St. Lucie Unit 2 Response to RAis #10 & 11 (NRC ADAMS Accession No. ML15190A336) on the SL2-21 SG Tube Inspection Report.

2 Array exam extended for detecting foreign object (FO) wear at the TTS and freespan, and for detecting FOs.

NDE Degradation Mechanism Technique Location/Description Status 11

+Point' PLP Wear (morphology dependent) 3 Potential 12

+Point' Wear at V-shaped support Existing structure (V-SSP)

Shape-dependent volumetric 13 Array indications (freespan; part not Potential present)

Type Volumetric Volumetric Volumetric L-2019-064 Enclosure Page 3 of 89 ETSS detection/sizing 27901.1 Rev 1, 27902.1 Rev 2, 27903.1 Rev 1, 27904.1 Rev 2, 27905.1 Rev 2, 27906.1 Rev 1, 27907.1 Rev 2 See footnotes3* 4 17901.1 /.3 Rev 0 17902.1/.3 Rev 0 17903.1/.3 Rev 0 17904.1/.3 Rev 0 17905.1/.3 Rev 0 17906.1/.3 Rev 0 D. Location, orientation (if linear), and measured sizes {if available) of service induced indications The actual listing of service-induced indications identified during the SL2-24 inspection is attached in Appendix B thru F of this report, per the index table below (Table 2a). Unless noted otherwise, each Appendix contains Indications for both SG-2A and SG-2B.

Table 2a - Indexed listing of Indications in Appendix 8 thru F Description Appendix No. of Pages Bobbin; All TSP Wear B

4

+Point'; Wear at V-shaped support pads (V-SSP) c 2

Bobbin; AVB U-bend ApexWear5 (AV4/5, AV3/6)

D 2

Bobbin; AVB Wear ~40% TWO E

2 Bobbin; AVB Wear 20-39%, 1-19% TWO F

73 Table 2b summarizes the number of tubes and number of indications associated with wear at AVBs and at TSPs. In Appendix D (AVB U-Bend Apex wear), 15 of the 23 tubes in SG-2A and 8 of the 13 tubes in SG-2B also had typical AVB wear elsewhere and are listed in Appendix F.

Table 2b-AVB and TSP Wear Summary: Tubes and Indications SG2A SG2B Location No. of No. of Tubes Indications Tubes Indications AVBs 2665 8958 2087 6185 TSPs 152 196 159 202 3 ETSS 27905.1 Rev. 1 was first used during SL2-21 to provide supplemental V-SSB wear sizing information. ETSSs 27901.1 thru 27907.1 have been extended for sizing V-SSB wear.

4 Site specific qualification forV-SSP wear per AREVA (proprietary) document 51-9193913, "Appui Wear Detection and Sizing Site Qualification".

5 Note: AV4/5 and AV3/6 AVB U-bend Apex wear occur on tubes in Rows 69 and 40, respectively. Additional info on AVB U-bend Apex wear is documented in the St. Lucie Unit 2 Response to RAJ #10 in NRC ADAMS document, ML15190A336.

L-2019-064 Enclosure Page 4 of 89 E. Number of tubes plugged during the inspection outage for each active degradation mechanism The number of tubes plugged for each active degradation mechanism is summarized below in Table 3:

Table 3 -Tubes Plugged during SL2-24 inspection outage Reason for Plugging SG2A SG2B Total AVB Wear<:: 40%- Tech Spec limit 27 0

27 AVB Wear< 40%- preventive plugging 6 48 6

54 AVB U-bend Apex Wear (AV4/5, AV3/6) 7 0

0 0

PLP indications - preventive plugging 4

0 4

Wear at V-shaped support pad (V-SSP) 0 0

0 TSPWear 0

0 0

Total 79 6

85 F. Total number and percentage of tubes plugged to date The total number and percentage of tubes plugged to-date in each SG is summarized below in Table 4:

Table 4-Cumulative Tube Plugging Summary following the SL2-24 Inspection SG Total Plugged

%Plugged 2A 377 4.19%

28 46 0.51%

G. The results of condition monitoring, including the results of tube pulls and in-situ testing All SG tubes inspected during the SL2-24 outage satisfied the condition monitoring (CM) requirements for structural and leakage integrity. No evidence of corrosion degradation was found, and no indications were found to exceed structural limits.

1. The largest TSP Wear (%TWO) indications were 28% and 25%, in SG-2A and SG-28, respectively. The largest growth (since the last inspection) of any TSP indication was 8%

TWO. All detected TSP wear indications fell below the CM limit for burst and leakage.

The voltages for all TSP indications that were inspected with +Point' were less than 3.0 volts, confirming the burst and leakage integrity for the tubes and in-situ pressure testing was not required. No tubes were plugged due to TSP Wear. The list of TSP Wear indications identified during SL2-24 is provided in Appendix B.

2.

Five (5) wear indications were identified during SL2-24 which were associated with V-shaped support pad (V-SSP) locations. Four (4) of these indications were previously-identified; one new V-SSP indication was identified in SG-28 during SL2-24. Each wear indication was shallow in depth, and previously-identified indications showed little to no growth since the last inspection. All V-SSP indications were sized with a qualified sizing technique, met the CM margin requirements, and the tubes were returned to service based on a plug-on-NOE sizing 6 These additional tubes were selected for preventive plugging based on a chosen criteria. This preventive measure allows for additional margins on wear rates, and to limit the likelihood that CM screening limits would be exceeded during the next scheduled inspection (SL2-26).

7 The SG AVB arrangement for St. Lucie 2 is shown in Figure 2 of document with NRC ADAMS Accession No. ML14279A237.

L-2019-064 Enclosure Page 5 of 89 approach (See NDE Technique #12 of Table 1). No wear indications were identified on tubes adjacent to V-SSP location (known as v-shaped support bars or V-SS8s). The list of V-SSP indications is provided in Appendix C.

3.

During the primary side ECT examinations, no tube degradation was detected at any of the locations where possible loose parts (PLPs) were reported on the secondary-side of the SGs.

Three (3) PLP indications (1 in SG-2A; 2 in SG-28), were detected at or near the TTS. The PLP signals had no associated wear on neighboring tubes as detected using the Array probe and confirmed using the +Point' probe. Since secondary-side FOSAR was not performed during SL2-24, the affected and bounding tubes (4 total) in SG-2A were preventively removed from service by plugging and stabilizing. The PLPs in SG-28 are historical, and the object was previously identified as a sludge rock which has no potential to cause wear. These tubes remain in service.

4. AV8 U-bend Apex wear was detected on some tubes in Row 69 of both SGs using the bobbin probe, and on 1 tube in Row 40 of SG-2A. Row 69 and Row 40 are located just below the AV4/5 and AV3/6 design depth locations, respectively. The highest recorded indications of AVB U-bend Apex wear (AV4/5) was 33% lWD in SG-2A and 10% lWD in SG-28. All AV8 U-bend Apex wear indications were previously-identified, and the highest growth was 4%

TWO since the previous inspection. No indication of AV8 U-bend Apex Wear met the criteria for preventive plugging. AV8 U-bend Apex Wear indications are provided in Appendix D.

5.

Twenty-seven (27) tubes in SG 2A were reported as having AV8 Wear of 40% TWO or greater. These tubes were plugged based on wear indication depths exceeding the plugging limits provided in Technical Specifications. The highest AV8 wear indications measured 44%

lWD in SG-2A and 39% TWO in SG-28. The list of AV8 Wear indications <:: 40% TWO is provided in Appendix E. A number of AV8 Wear indications (with <40% TWO) were identified during the SL2-24 inspection. To provide added margin on wear rates and to limit the likelihood that the CM screening limits would be exceeded during the next scheduled inspection (SL2-26), 54 additional tubes (48 in SG-2A, 6 in SG-28) were selected for "preventive plugging" based on a developed criteria comprised of indication depths, growth rates and/or number of indications on the tubes. A complete listing of AV8 Wear indications (with <40% lWD) is provided in Appendix F. All detected wear at AV8 supports met the required integrity margins for CM, whether sized by bobbin or +Point', and AV8 wear indications met the CM requirements for burst and leakage.

6. Although the industry operating experience described in Westinghouse NSAL 12-01 8 Rev 1 is not directly applicable to St. Lucie Unit 2, supplemental visual inspection of the primary-side channel head bowl (in both SGs) was performed in accordance with the recommendations presented in the NSAL. The channel head and tubesheet cladding were also inspected for rust stains and loss of material. All previously-installed tube plugs in the HL and CL were visually inspected during the SL2-24 inspection outage. All plugs were confirmed to be in their correct locations, and showed no visible signs of leakage based on the visual examination.

No degradation of the tube plugs, tubesheets, divider plate assemblies or primary-side channel head bowl areas were noted apart from that incurred during a historical foreign object event in SG-289. No corrosion-related degradation was identified in any of the SG channel head components.

7.

Secondary-side inspection activities were mainly comprised of a visual inspection of the feedwater ring support system in each SG. The inner support brackets of the SG-2A feedring were found to be slightly deformed from a pressure transient in the feedring during the last operating cycle. This condition was expected for SG-2A based on monitoring criteria 8 Westinghouse NSAL-12-1 Rev 1, "Steam Generator Channel Head Degradation", October2, 2017.

9 This event is described in Section G Item #8 of the SL2-22 SG Tube Inspection Report (NRC ADAMS Accession No. ML16111B235).

L-2019-064 Enclosure Page 6 of 89 established for this phenomenon, and does not jeopardize SG tube integrity. All welds of the feedring support system were noted to be intact. The as-found condition was documented in the corrective action program, and the brackets were repaired by attaching support braces/stiffeners to them. No deficiency was observed with the SG-28 feedring supports. No secondary-side cleaning activities such as upper tube bundle flush, sludge lancing or FOSAR were performed during SL2-24.

In summary, all wear indications detected (at AVB, V-SSP and TSP locations), met CM requirements. Therefore, no tubes required in-situ pressure testing for either tube burst or leakage based on the SL2-24 inspections. All tubes met the structural and leakage integrity requirements of the St. Lucie Unit 2 Technical Specifications. No tube pulls were required.

H. The effective plugging percentage for all plugging in each SG No tube repair methods (such as sleeving) are approved for St. Lucie Unit 2 that would have an effect on the effective plugging percentages. Therefore, the effective plugging percentage for each SG is the same as the Percentage of Tubes Plugged in "Item F" above.

APPENDIX A - Additional Information References to prior SG Tube Inspection Reports EOC Outage ADAMS Accession No.

EOC-17 SL2-18 (1 51 lSI)

ML093230226 EOC-18 SL2-19 ML11270A015 EOC-19 SL2-20 ML13141A479 EOC-20 SL2-21 ML14279A237 EOC-21 SL2-22 ML16111B235 EOC-22 SL2-23 ML17257A080 Abbreviations and Acron~ms AVB Anti-Vibration Bar OD Outside Diameter CL Cold Leg PLP Possible Loose Part CM Condition Monitoring PWSCC Primary Water Stress Corrosion Cracking EOC-23 End-of-cycle 23 (SL2-24 inspection)

RSG Recirculating Steam Generator EFPM Effective Full Power Months SG Steam Generator EFPY Effective Full Power Years SSI Secondary Side Inspection EPRI Electric Power Research Institute TSP Tube Support Plate ETSS Exam Technique Specification Sheet TIS Top ofTubesheet FO Foreign Object TWD Through Wall Depth HL Hot Leg V-SSB V-Shaped Support Bar wear (side bar wear) lSI In-service Inspection V-SSP V-Shaped Support Pad wear (appui wear)

WAR Mechanical Wear

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin TSP Wear 1-19%

ROW COL %TW LOCATION 1

2 12 04C +0.41 12 04H-0.67 1

52 8

05C +0.35 1

60 10 04C +0.42 1

62 16 04C +0.37 1

80 12 06C -0.65 1

82 10 05C +0.35 11 05C -0.58 1

86 15 05C +0.25 9

05C -0.67 15 04C +0.25 11 04C -0. 60 1

92 11 04C +0.32 10 02C -0.60 1

96 8

02C +0.42 1

140 7 06C -0.85 10 05C -0.60 i2 04C +0.37 15 04C -0.64 1

154 12 05C +0.35 15 05C -0.64 9

04C +0.39 1

156 10 04C +0.32 1

160 15 05C -0.76 16 04C -0.64 1

162 13 05C -0.69 1

168 9 05C +0.44 15 05C -0.67 19 04C +0.41 11 04C -0. 62 2

2 2

2 2

2 3

3 3

3 4

4 4

4 5

5 5

5 6

6 6

1 7

06H -0.60 5

8 05C +0.53 15 05C -0.58 13 04C +0.46 8

04C -0.71 61 9

9 91 11 97 8

121 12 2

8 8

10 9

158 9 168 7 10 15 5

9 73 6

143 6 151 7 58 9

82 10 164 9 9

168 12 7

7 9

9 169 5 04C +0.37 02C +0.37 04C -0.65 02C +0.39 04C +0.41 04H -0.56 04H +0.42 04H -0.72 05C -0.78 05C +0.39 05C -0.62 04C +0.39 04C +0.39 04C +0. 37 04C -0.74 04C -0.67 04C -0.76 03H +0.37 05C +0.37 05C -0.74 05C -0.71 04C +0.58 04H -0.65 04C -0.71 7

2 11 04C +0.53 7

92 10 01C +0.57 10 10 10 12 13 14 14 8

1 6

3 7

9 7

141 7 2

7 13 8

167 6 04C +0.44 04H -0.65 04C -0.62 04H +0.39 04C -0.65 04H -0.65 04H -0.63 05C -0.65 15 168 11 05H +0.37 17 2

11 04H +0.48 18 91 6

03C -0.52 Appendix B: Wear at TSPs Unit: 2 Component: S/G A ROW COL %TW LOCATION 23 58 8

04C +0.33 30 9

8 05C -0.72 30 31 35 37 47 48 53 53 54 55 57 57 58 59 60 60 61 62 63 64 67 68 69 17 9

66 7

118 6 6

5 162 8 9

8 158 10 162 12 159 11 14 6

10 6

14 7

157 11 160 9 157 7 159 8 152 13 85 7

156 10 157 12 156 13 157 9 16 6

70 151 11 72 155 11 73 18 9

74 71 12 75 22 11

77. 18 6

77 20 15 79 22 6

79 26 5

79 130 8 80 17 9

81 18 10 18 9

03H -0.60 02C +0.50 02H -0.34 04C +0.44 05C +0.46 04C +0.40 05C +0.40 05C +0.44 05C +0.49 04H -0.40 04C +0.42 04H -0.65 05C +0.44 05C +0.47 05C -0.62 05C +0.47 05C +0.50 03H -0.60 05C -0.56 05C +0.46 05C +0.40 05C -0.60 05H +0.48 05C +0.46 05C +0.37 04H -0.67 07C +0.14 04H -0.63 04H +0.48 04H -0.67 04H -0.65 04H -0. 56 04C +0.37 04H -0.07 04H -0.66 04H +0.39 05H -0.67 86 21 15 04H -0.63 8

05H -0.67 87 26 7

04H -0.69 87 28 8

06H -0.74 88 25 14 04H -0.65 15 04H +0.48 89 22 17 04H +D.37 6

04H -0.70 90 23 5

04H -0.65 90 33 5

05H -0.86 8

04H -0.63 92 25 9

04H +0.46 92 27 10 04H +0.49 92 29 10 04H +0.51 93 26 8

04H -0.70 93 34 7

04H -0.70 94 31 8

04H +0.53 94 37 6

04H -0.55 94 141 7 03H +0.49 95 36 10 04H -0.68 96 27 6

07H -0.57 96 29 11 04H -0.65 96 31 5

04H -0.68 98 143 10 07H -0.61 99 28 9

04H -0.63 14 04H +0.44 99 30 8

04H -0.65 100 29 4

06H -0.90 100 31 8

05H -0.55 102 39 10 04H -0.63 8

04H +0.51 103 32 11 04H -0.70 10 04H +0.51 L-2019-064 Enclosure Page 7 of 89 Page 1 of 1 ROW COL %TW LOCATION 103 42 9

04H +0.51 106 43 6

04H -0.65 106 45 9

04H -0.69 108 39 11 04H -0.68 108 111 9 03C -0.61 109 34 18 10 109 40 13 109 42 10 110 39 12 110 43 7

111 36 11 10 04H +0.48 04H -0.58 04H -0.67 07C -0.70 04H +0.49 04H -0.40 04H -0.65 07H -0.54 9

07H +0.42 111 38 8

04H +0.46 111 134 7 05C +0.37 11 04C -0.72 113 38 7

04H -0.65 116.41 10 04H -0.69 117 42 8

04H +0.48 117 128 7 03C -0.61 119 42 9

04H -0.65 9

05H -0.56 119 44 7

120 45 10 120 111 8 121 124 11 122 45 6

7 122 47 6

124 49 9

127 100 6 129 80 9

129 96 13 129 114 10 130 57 8

131 92 15 131 104 6 131 108 7 131 110 9 9

8 8

133 106 8 134 103 12 8

134 105 11 135 78 9

136 77 11 138 83 14 05H -0.53 04H +0.46 05C +0.38 05C -0.66 04H -0.67 04H +0.44 05H -0.58 04H -0.56 05C +0.39 05C +0.41 05C +0.46 06H -0.67 04H -0.55 05C +0.46 04C +0.37 03C +0.38 05C -0.49 03C +0.40 04H +0.46 05H +0.44 05C +0.40 05H +0.46 06H +0.44 05H +0.41 04C -0.53 03H +0.39 05H +0.23 Total Tubes 151 Total Records: 194

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin TSP Wear 20-39%

ROW COL %TW LOCATION 2

1 28 04C -0.60 2

7 23 04C -0.60 Total Tubes 2

Total Records: 2 Appendix 8: Wear at TSPs Unit: 2 Component: S/G A ROW COL %TW LOCATION L-2019-064 Enclosure Page 8 of 89 Page 1 of 1 ROW COL %TW LOCATION

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin TSP Wear 1-19%

ROW COL %TW LOCATION 1

32 9

04C -0.56 1

56 17 05C -0.65 1

70 12 05C -0.58 1

72 9

05C +0.40 1

76 10 05C +0.40 9

05C -0.67 1

78 9

05C +0.40 1

82 14 04C +0.14 17 06C +0.00 8

04C -0.67 1

84 15 04C -0.19 1

110 10 04C -0.65 1

116 17 05C -0.72 1

126 9 04C -0.63 1

148 15 05C -0.58 1

154 11 05C +0.40 10 04C +0.35 1

166 13 06C +0.40 1

168 14 04C +0.33 11 05H -0.80 2

7 13 05C +0.02 8

06C -0.58 2

9 9

04C +0.44 9

04C -0.67 2

21 10 05C -0.21 2

63 12 04C +0.37 16 04C -0.63 6

03C +0.35 2

69 11 04C -0.51 2

75 11 02C +0.44 2

89 10 05C -0.56 2

91 9

05C -0.72 8

05C +0.37 2

95 6

05C -0.63 2

111 9 05C -0.70 2

113 6 05C -0.67 2

115 11 05C +0.35 2

125 8 05C +0.40 2

157 10 04C +0.40 2

159 7 04C +0.44 2

169 9 06C +0.35 14 05C +0.42 3

30 7

05C -0.58 3

40 8

04C +0.40 3

46 8

04C +0.40 3

52 11 05C -0.19 3

60 7

05C +0.35 8

05C -0.65 12 04C +0.37 9

04C -0. 60 3

70 7

04C +0.44 3

82 7

05C +0.37 3

168 11 03C -0.67 4

45 4

57 4

71 5

76 10 53 11 80 16 3

17 36 17 82 7

04C +0.42 15 05C +0.26 14 05C +0.28 7

05C +0. 40 9

05C +0.37 12 05H +0.44 10 04C +0.37 9

04H+0.47 7

05C +0.35 5

05C +0.37 18 167 12 05H -0.65 20 17 13 04H +0.46 20 167 13 05H -0.76 22 45 11 04H -0.62 17 04C -0.75 22 85 9

01C -0.68 22 125 9 03C -0.63 31 10 12 04C -0.55 36 5

9 04C -0.72 Appendix B: Wear at TSPs Unit: 2 Component: S/G B ROW COL %TW LOCATION 39 8

10 04C -0.72 42 7

13 44 7

16 44 15 9

45 ' 8 8

51 20 7

54 13 11 55 160 10 10 61 12 13 61 160 12 66 153 13 67 14 18 68 19 15 13 68 151 9 04C -0.81 04C -0.72 04C +0.42 04C -0.72 04H +0.51 04C -0.74 05H -0.67 04H -0.69 04C -0.74 05C +0.46 05C +0.46 04C -0.60 07C -0.86 03C -0.69 05H -0.77 70 13 10 04C +0.35 16 04C -0.74 11 05C +0.23 72 19 8

07C -0.65 74 15 11 05C -0.37 75 18 11 05C +0.30 7 5 72 12 77 152 11 78 19 14 81 152 12 13 86 21 19 86 27 7

86 141 8 87 22 7

89 144 9 91 70 8

93 146 8 99 142 7 12 8

100 141 8 104 139 10 105 138 8 106 33 6

107 60 8

107 62 6

108 137 7 10 9

109 56 9

112 37 6

113 54 7

113 60 7

114 45 9

115 56 7

116 131 18 117 50 5

118 41 9

11 120 127 8 04H -0.65 05C +0.51 07C -0.65 05H +0.65 04H +0.30 04H +0.46 04H +0.49 05C +0.43 04H +0.43 03C -0.54 07C -0.81 05H -0.70 05H -0.65 06C +0.26 05C -0.61 05H -0.67 06C -0.65 05H +0.46 04H -0.65 05C +0.30 05C -0.65 05C +0.37 05C -0.61 04C -0.56 07C -0.85 04H -0.62 05C -0.78 05C +0.26 04C +0.42 06C +0.38 05C -0.65 04H -0.70 04H -0.60 06C +0.28 04C +0.40 121 46 10 06C +0.28 121 48 6

05C -0.60 121 126 17 04C -0.50 122 51 10 06C -0.65 122 107 11 04C -0.63 123 46 4

9 123 50 8

8 124 51 6

04H -0.71 05C -0.61 06C +0.30 06C -0.77 04H -0.51 10 06C -0.77 124 55 10 05C -0.61 124 57 8

05C -0.76 124 101 10 04C -0.63 124 103 7 04C -0.58 L-2019-064 Enclosure Page 9 of89 Page 1 of 1 ROW COL %TW LOCATION 125 54 8

06C -0.72 125 68 7

05C +0.28 126 51 3

04H -0.40 126 75 10 03C -0.56 126 113 7 04H +0.39 127 58 5

06C -0.65 127 70 7

03C -0.76 128 63 11 03C -0.72 128 73 8

04H +0.37 129 78 8

03C -0.56 129 104 9 04C -0.58 130 57 10 07H +0.38 130 63 11 04H +0.44 130 67 8

05C +0.37 11 07C -0.77 130 99 14 130 103 6 131 68 5

8 131 82 9

131 96 10 131 98 11 131 106 9 133 66 9

04C -0.63 04H -0.65 06C +0.35 05C +0.40 03C -0.61 04C -0.60 06C +0.34 04H +0.44 07C -0.79 133 76 11 05C +0.45 133 92 8

04C -0.55 133 102 11 04H -0.66 9

04H +0.44 133 106 8 04C -0.63 133 108 8 04H +0.51 134 65 14 07H +0.37 10 05C +0.65 134 71 7

06C +0.32 134 83 10 03C -0.63 134 89 8

04H +0.35 134 91 14 07C +0.31 135 70 9

06C +0.32 12 05C +0.42 135 74 12 04H +0.42 136 71 15 05C +0.28 136 73 13 05C +0.38 136 77 10 03C -0.61 10 05C +0.45 10 04H+0.72 136 91 9

04C -0.61 137 82 18 07C +0.35 137 92 12 04C +0.47 138 73 16 04H +0.46 8

05C -0.07 138 79 12 03C -0.50 10 05C +0.41 138 81 7

03C -0.77 139 86 11 06C -0.69 12 06C +0. 42 Total Tubes 159 Total Records: 198

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Bobbin TSP Wear Plant: St Lucie 20-39%

ROW COL %TW LOCATION 1

82 24 05C -0.67 24 05C 1

84 22 05C 1

168 25 05C Total Tubes 3

Total Records: 4

+0.28

+0.23

-0.14 Appendix B: Wear at TSPs Unit: 2 Component: S/G B ROW COL %TW LOCATION L-2019-064 Enclosure Page 10 of 89 Page l of 1 ROW COL %TW LOCATION

Framatome Inc Customer: FPL 09/18 -

EOC23 Plant: St Lucie Appendix C: Wear at V-SSPs 09/14/18 11:24:12 Unit: 2 Component: S/G A Tubes with VPAD (V-SSP) Wear Indications ROW COL VOLTS DEG 120 43 0.13 81 135 102 0.15 272 Total Tubes 2

Total Records: 2 CHN P7 P7 IND %TW LOCATION UTIL 1 LEG

--- ---===========================

WAR AV7 +23.60 17 COLD WAR AV3 +0.96 18 HOT Note: the "UTIL 1" entries represent %TWD values.

L-2019-064 Enclosure Page 11 of 89 Page 1 of 1

Appendix C: Wear at V-SSPs 09/14/18 11:22:48 Framatome Inc Customer: FPL Plant: St Lucie Unit: 2 Component: S/G B 09/18 - EOC23 Tubes with VPAD (V-SSP)

ROW COL VOLTS DEG 73 14 0.12 260 110 135 0.22 88 112 133 0.24 265 Total Tubes 3

Total Records; 3 CHN P7 P7 P7 Wear Indications IND %TW LOCATION UTIL 1 LEG

--- ---===========================

WAR AV2 +1. 63 16 HOT WAR AV8 -1.71 24 COLD WAR AV7 +22.69 24 COLD Note: the "UTIL 1" entries represent %TWO values.

L-2019-064 Enclosure Page 12 of 89 Page 1 of 1

Frarnatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Appendix 0: Wear at AVB U-bend Apex Unit: 2 Component: S/G A Bobbin AVE Wear in AVE Transition Row Tubes (Crossover Tube)

ROW COL %TW LOCATION ROW COL %TW LOCATION 40 145 5 AV3 +1.22 69 74 14 AV4 -0.91 69 98 17 AV4 +0.50 69 100 24 AV4 +0.45 69 102 30 AV4 +1. 24 69 104 18 AV4 +1.13 69 106 33 AV4 +1. 09 69 108 32 AV4 +1. 28 69 110 16 AV4 +1.25 69 112 23 AV4 +1.08 69 114 9 AV4 +0.00 69 116 6 AV4 +1. 04 69 118 9 AV4 +1. 09 69 120 8 AV4 +1. 29 69 122 8 AV4 +0.90 69 124 6 AV4 +0.81 69 126 5 AV4 +0.90 69 128 5 AV4 +1. 06 69 130 6 AV4 +0.97 69 132 5 AV4 +0.89 69 136 7 AV4 +0.76 69 138 9 AV4 -0.11 69 144 9 AV4 +0. 06 Total Tubes 23 Total Records: 23 L-2019-064 Enclosure Page 13 of 89 Page l of l ROW COL %TW LOCATION

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Appendix D: Wear at AVB U-bend Apex Unit: 2 Component: S/G B Bobbin AVB Wear in AVB Transition Row Tubes (Crossover Tube)

ROW COL %TW LOCATION ROW COL %TW LOCATION 69 18 8

AV4 +0.98 69 20 7

AV4 +1.09 69 24 6

AV4 +1.12 69 36 7

AV4 +1.19 69 44 7

AV4 +1.11 69 46 5

AV4 +0.98 69 52 4

AV4 +0.87 69 56 6

AV4 +1.16 69 62 10 AV4 +1. 00 69 78 10 AV4 +1. 48 69 84 5

AV4 +0. 81 69 92 8

AV4 +1. 03 69 98 8

AV4 +0.97 Total Tubes 13 Total Records: 13 L-2019-064 Enclosure Page 14 of 89 Page 1 of 1 ROW COL %TW LOCATION

Appendix E: Wear >=40% at AVBs (T.S. req'd)

L-2019-064 Enclosure Page 15 of 89 Framatome Inc.

Customer: FPL Plant: St Lucie Unit: 2 Component: S/G A Page 1 of 1 09/18 -

EOC23 Bobbin AVB Wear 40-100%

ROW COL %TW LOCATION ROW COL %TW LOCATION ROW COL %TW LOCATION 75 102 41 AV5 +0.09 77 98 40 AV5 +0.07 80 71 40 AV5 +0.05 81 72 40 AV6 +0.07 83 98 43 AV4 +0.08 83 102 41 AV6 +0.07 87 92 41 AV6 +0.07 90 73 40 AV6 +0.05 91 94 40 AV4 -0.02 92 91 40 AV3 -0.05 93 72 40 AV5 +0.09 93 76 40 AV6 -0.05 40 AV5 -0.03 94 91 40 AV3 -0.05 94 99 41 AV6 -0.05 94 105 41 AV5 +0.07 95 90 40 AV7 -0.02 95 94 40 AV6 +0. 00 40 AV5 -0.03 98 75 40 AV7 -0.07 102 75 40 AV7 -0.05 105 94 40 AV5 -0.03 109 74 40 AV6 +0.07 109 102 40 AV5 +0.07 110 71 40 AV3 +0.00 111 94 41 AV3 +0.00 124 79 40 AV4 -0.09 41 AV3 -0.07 133 96 40 AV4 +0.00 137 80 41 AV5 -0.08 44 AV4 -0.12 Total Tubes 27 Total Records: 31

Appendix E: Wear >=40% at AVBs (T.S. req'd)

L-2019-064 Enclosure Page 16 of 89 Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 40-100%

ROW COL %TW LOCATION Total Tubes 0

Total Records: 0 Unit: 2 Component: S/G B Page 1 of 1 ROW COL %TW LOCATION ROW COL %TW LOCATION

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 24 167 7 AV7 +0.29 25 166 12 AV7 +0.21 26 19 5

AV1 -0.09 27 4

7 AV7 +0.36 27 164 6 AV7 -0.40 29 4

7 AV2 -0.23 6

AV7 +0.35 29 29 30 31 31 32 33 6

8 166 6 5

6 164 6 166 7 8

12 163 7 6

9 AV8 -0.15 AV7 +0.30 AV2 -0.20 AV7 +0.22 AV1 -0.13 AV2 -0.22 AV7 +0.28 AV7 -0.27 AV2 -0.16 11 AV7 +0.27 9

AV8 +0.05 33 33 33 34 34 34 8

8 162 5 164 9 12 5

9 7

8 163 7 8

34 165 8 35 6

8 35 8

8 35 162 6 35 36 36 36 36 37 37 37 37 37 38 38 38 38 38 38 38 39 164 10 7

8 9

161 5 163 6 165 6 6

8 8

9 158 7 162 7 7

7 6

164 6 5

7 7

6 11 9

8 6

6 7

11 5

6 161 8 7

163 9 9

165 12 6

6

'12 AV2 -+'0.32 AV2 -0.23 AV7 +0.17 AV2 -0.28 AV7 +0.32 AV7 +0.27 AV7 +0.18 AV2 -0.27 AV7 +0.16 AV7 -0.24 AV7 +0.25 AV2 -0.02 AV7 +0.20 AV2 -0.15 AV7 +0.25 AV7 +0.12 AV2 -0.30 AV7 +0.19 AV7 +0.28 AV7 +0.24 AV7 -0.21 AV8 +0.14 AV7 +0.16 AV2 -0.05 AV7 -0.33 AV7 -0.29 AV7 +0.32 AV2 +0.23 AV7 +0.27 AV1 +0.23 AV2 +0.10 AV7 -0.20 AV8 -0.14 AV2 +0.28 AV7 -0.20 AV7 -0.25 AV2 +0.18 AV7 +0.20 AV2 -0.27 AV7 +0.20 AV1 -0.24 AV2 -0.14 10 AV7 +0.30 39 8

9 AV7 +0.25 39 10 8

AV7 +0.21 39 162 10 AV7 +0.14 6

AV2 -0.26 39 164 11 11 40 7

10 11 40

  • 9 15 11 40 11 7

AV7 +0.20 AV2 +0.16 AV2 -0.16 AV7 +0.28 AV7 -0.16 AV8 -0.17 AV7 -0.16 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 40 161 6 AV7 -0.24 40 163 7 AV1 +0.19 41 6

8 AV7 -0.18 41 8

7 AV2 -0.12 6

AV8 -0.16 6

AV7 +0.28 41 158 7 AV7 -0.14 8

AV8 +0.26 41 162 13 AV2 +0.16 41 164 9 AV7 -0.21 9

AV2 -0.25 42 7

11 AV7 +0. 02 7

AV8 -0.18 8

AV2 -0.14 7

AV3 -0.13 12 AV7 -0.19 42 9

42 159 7 42 161 7 AV7 -0.21 AV8 -0.23 16 AV6 +0.17 6

AV7 +0.11 10 AV7 -0.30 42 163 6 AV8 -0.22 10 AV7 -0.25 12 AV2 +0.17 43 6

5 AV2 +0.33 4

AV3 -0.33 6

AV6 +0. 40 11 AV7 -0.21 9

AV7 +0.28 7

AV8 +0.27 43 43 43 43 43 43 43 44 44 44 44 44 44 44 44 8

7 7

8 124 5 154 7 9

158 7 160 6 162 5 8

164 8 8

6 7

6 7

11 12 10 9

6 6

6 9

11 5

7 141 7 153 8 157 10 159 6 161 11 7

AV1 +0.25 AV6 +0.35 AV7 +0.24 AV2 +0.24 AV6 +0.31 AV3 -0.37 AV6 +0.26 AV1 +0.14 AV7 +0.16 AV6 +0.32 AV7 +0.16 AV6 +0.30 AV2 -0.27 AV1 -0.16 AV2 -0.16 AV3 -0.20 AV6 +0.30 AV7 +0.23 AV2 -0.09 AV3 -0.14 AV6 +0.29 AV8 -0.11 AV2 -0.14 AV8 -0.14 AV6 -0.28 AV6 -0.54 AV7 -0.18 AV7 -0.22 AV6 +0.22 AV6 -0.52 44 163 8 AV8 -0.24 10 AV6 +0.22 7

AV6 -0.48 9

AV2 +0.16 6

AV1 -0.20 45 45 45 45 45 8

5 7

8 12 6

14 5

120 5 130 5 AV2 -0.17 AV6 +0.31 AV7 +0.23 AV2 -0.09 AV3 -0.14 AV3 -0.20 AV6 +0.23 L-2019-064 Enclosure Page 17 of 89 Page 1 of 32 ROW COL %TW LOCATION 45 142 9 AV6 +0.22 45 154 8 AV6 +0.18 14 AV3 -0.27 45 156 5 AV7 +0.43 6

AV6 +0.18 45 158 9 AV6 +0.23 8

AV8 +0.26 45 160 8 AV7 +0.13 8

AV2 -0.28 45 162 7 AV8 -0.25 6

AV7 +0.16 13 AV6 +0.22 6

AV3 -0.29 10 AV2 -0.21 7

AV1 -0.22 46 7

9 AV3 -0.21 12 AV7 +0.24 46 9

7 AV2 -0.16 11 AV6 +0.25 46 11 9

AV2 -0.12 9

AV3 -0.16 9

AV6 +0.20 8

46 13 6

46 35 5

46 141 9 AV7 +0.25 AV2 -0.12 AV3 +0.34 AV6 -0.24 46 157 7 AV6 -0.43 6

AV1 -0.20 46 159 9 AV7 +0.16 7

AV6 +0.18 46 46 47 47 47 47 47 47 47 47 48 161 17 11 9

163 6 13 9

7 8

7 9

13 12 7

10 7

12 7

44 7

142 8 154 8 16 160 8 7

7 11 8

162 10 10 18 9

10 7

10 13 AV6 +0.20 AV2 -0.23 AV7 +0.18 AV8 +0.16 AV7 +0.16 AV6 +0.16 AV2 -0.30 AV2 +0.14 AV3 -0.16 AV6 +0.22 AV7 +0.25 AV8 +0.25 AV7 +0. 23 AV8 +0.02 AV3 -0.16 AV6 +0.23 AV6 +0.16 AV3 -0.25 AV8 -0.23 AV7 +0.14 AV6 +0.16 AV2 -0.28 AV1 +0.14 AV8 -0.23 AV7 -0.25 AV6 +0.16 AV3 -0.27 AV2 -0.23 AV3 -0.18 AV6 +0.23 48 9

8 AV7 +0.25 10 AV2 -0.15 10 AV3 -0.18 12 AV6 +0.27 8

AV7 +0.25 48 48 48 48 11 13 15 35 8

7 11 6

6 7

9 AV8 +0.23 AV2 -0.10 AV7 +0.20 AV2 -0.10 AV3 -0.09 AV3 -0.13 AV3 +0.34

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 48 141 7 AV6 -0.22 48 147 10 AV6 +0.05 48 153 6 AV6 -0.39 48 157 5 AV6 +0.16 48 159 6 AV7 +0.16 8

AV3 +0.24 48 161 11 AV7 +0.14 18 AV6 +0.21 12 AV2 -0.18 5

AV1 +0.16 48 163 10 AV7 -0.25 7

AV3 +0.24 7

AV2 -0.28 49 8

7 AV2 -0.16 10 AV3 -0.18 7

AV6 +0.25 7

AV7 +0.23 49 10 8

AV2 -0.12 6

AV3 -0.14 7

AV6 +0.25 12 AV7 +0.18 49 12 6

AV2 -0.07 6

AV3 -0.09 8

AV8 +0.05 49 16 7

AV3 +0.35 15 AV6 -0.03 49 22 4

AV2 +0.28 49 26 5

AV3 -0.14 49 34 6

AV3 -0.09 49 128 5 AV3 -0.07 49 142 7 AV6 +0.25 49 144 7 AV3 +0.37 49 154 7 AV6 +0.18 11 AV3 -0.27 49 156 7 AV7 +0.17 49 158 10 AV3 +0.44 7

AV6 -0.23 49 49 50 7

160 7 10 10 162 9 13 6

11 7

7 8

AV7 -0.16 AV8 -0.23 AV7 +0.14 AV2 -0.25 AV7 +0.14 AV6 +0.18 AV3 -0.29 AV2 -0.25 AV2 +0.34 AV3 -0.25 12 AV6 +0.25 9

AV7 +0.26 50 9

6 AV2 -0.14 11 AV3 -0.18 13 AV6 +0.27 10 AV7 +0.25 7

AV8 +0.23 50 50 50 50 50 50 50 50 50 50 11 16 AV2 -0.09 5

AV3 -0.41 8

AV6 +0.23 10 AV7 +0.21 13 6

AV2 -0.09 4

AV3 -0.39 5

AV6 +0.20 15 8

AV3 -0.05 6

AV6 +0.23 5

AV7 +0.02 7

AV8 -0.14 19 6

AV3 -0.09 45 5

AV3 +0.06 111 6 AV6 +0.00 125 6 AV3 +0.17 137 6 AV6 +0.23 147 6 AV6 +0.25 153 9 AV6 -0.40 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 13 AV3 +0.23 50 155 16 AV6 -0.34 50 157 9 AV7 -0.25 6

AV6 -0.09 50 159 9 AV7 +0. 09 7

AV6 +0.18 7

AV3 +0.20 9

AV2 -0.21 50 161 11 AV7 +0.14 14 AV6 +0.18 9

AV6 -0.43 7

AV3 +0.23 8

AV2 -0.25 6

AV1 -0.20 50 163 13 AV7 -0.25 8

AV6 +0.18 5

AV3 +0.23 51 8

11 AV3 -0.18 13 AV6 +0.27 6

AV8 +0.25 51 10 9

AV2 -0.05 7

AV6 +0.25 6

AV7 +0.21 9

AV8 +0.23 51 12 8

AV3 +0.42 51 16 5

AV2 -0.07 11 AV6 -0.27 10 AV7 +0.00 9

AV8 +0.05 51 18 8

AV3 +0.16 51 34 6

AV3 -0.07 51 102 7 AV6 +0.22 51 108 6 AV6 +0.18 51 128 5 AV3 -0.19 51 144 10 AV3 +0.28 51 154 5 AV7 +0.14 51 51 51 10 AV6 +0.16 14 AV3 -0.25 156 10 AV7 +0.16 11 AV6 +0.16 158 7 AV3 +0.45 6

AV6 -0.21 7

AV7 +0.20 160 10 AV8 -0.23 10 AV7 +0.14 9

AV3 -0.05 17 AV2 -0.23 8

AV1 -0.02 51 162 12 AV7 -0.02 14 AV3 -0.02 17 AV2 -0.23 52 9

52 11 52 13 52 15 52 17 52 35 12 10 10 17 13 9

10 13 17 6

11 8

10 11 9

6 7

7 9

7 10 AV1 -0.20 AV3 +0.29 AV2 -0.17 AV3 -0.19 AV6 +0.22 AV7 +0.28 AV2 -0.12 AV6 +0.20 AV7 +0.23 AV8 -0.14 AV2 -0.12 AV6 +0.27 AV7 +0.00 AV8 +0.00 AV7 +0.02 AV8 -0.14 AV2 -0.14 AV3 -0.12 AV6 +0.25 AV8 +0. 07 AV3 +0. 37 L-2019-064 Enclosure Page 18 of 89 Page 2 of 32 ROW COL %TW LOCATION 5

AV6 -0.24 52 111 5 AV3 -0.09 52 121 7 AV3 +0.25 52 141 11 AV6 -0.16 52 145 6 AV1 +0.12 5

AV2 +0.21 52 147 6 AV6 +0.02 52 149 7 AV6 +0.11 52 151 8 AV7 -0.05 52 153 19 AV6 -0.33 16 AV3 +0.22 52 155 6 AV6 +0.41 52 157 5 AV6 +0.16 52 159 7 AV7 +0.16 10 AV6 -0.34 10 AV2 -0.23 7

AV1 -0.18 52 161 7 AV1 -0.22 53 8

11 AV7 -0.23 14 AV6 +0.21 7

AV3 +0.25 11 AV2 -0.23 16 AV2 +0.37 14 AV3 -0.21 9

AV6 +0.27 8

AV8 +0.25 53 10 6

AV1 +0.33 11 AV2 -0.05 7

AV3 -0.14 12 AV6 +0.20 10 AV7 +0.25 8

AV8 -0.16 53 12 7

AV2 -0.12 9

AV3 +0.16 9

AV8 -0.09 53 16 7

AV6 +0.00 53 20 7

AV3 -0.11 53 53 53 53 53 53 53 53 34 8

9 44 5

54 6

102 6 110 5 124 7 8

128 7 130 7 AV3 -0.12 AV6 +0.16 AV3 -0.14 AV3 +0.11 AV6 +0.22 AV3 -0.05 AV3 +0.11 AV7 +0.07 AV3 -0.07 AV6 +0.18 53 136 6 AV6 +0.02 53 142 13 AV6 +0.23 53 144 9 AV3 +0.43 53 53 53 53 53 53 54 8

AV7 +0.18 7

148 6 5

154 11 13 156 8 14 11 158 7 14 9

160 6 12 7

11 162 13 9

9 6

17 17 10 AV8 +0.21 AV6 +0. 00 AV7 +0.43 AV6 +0.14 AV3 -0.25 AV8 -0.25 AV7 +0.15 AV6 +0.14 AV3 +0.51 AV7 +0.23 AV8 +0.21 AV8 -0.23 AV7 +0.14 AV3 -0.05 AV2 -0.23 AV7 -0.25 AV3 -0.25 AV2 -0.19 AV6 +0.25 AV7 -0.16 AV8 +0.23

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 54 11 10 AV6 +0.25 11 AV7 +0.23 54 13 15 AV6 -0.21 11 AV7 +0.00 10 AV8 +0.02 54 15 6

AV2 -0.07 10 AV3 -0.07 54 19 7

AV3 -0.07 54 39 6

AV3 +0.32 54 101 7 AV6 -0.13 54 105 4 AV3 +0.08 54 109 9 AV3 +0.06 54 111 5 AV6 +0.05 54 119 5 AV6 +0.11 54 121 6 AV3 +0.33 7

AV6 -0.19 54 125 6 AV2 +0.05 54 135 7 AV6 +0.02 12 AV7 +0.04 54 137 7 AV2 -0.12 54 139 7 AV6 +0.05 54 141 9 AV6 -0.24 54 143 5 AV6 +0.23 54 145 5 AV7 +0.16 54 147 10 AV6 +0.23 54 151 8 AV7 -0.05 54 153 6 AV6 +0.18 8

AV3 +0.19 54 155 7 AV6 +0.14 5

AV1 +0.18 54 157 13 AV6 +0.14 15 AV3 -0.21 6

AV2 -0.23 6

AV1 +0.18 54 159 9 AV8 -0.25 15 AV7 +0.09 7

AV3 -0.21 10 AV2 -0.25 9

AV6 +0.14 10 AV6 -0.41 55 10 13 AV2 -0.09 8

AV3 -0.14 11 AV3 +0.41 16 AV6 -0.33 9

AV6 +0.25 14 AV7 -0.18 8

AV7 +0.23 55 12 7

AV1 -0.07 7

AV2 -0.09 10 AV3 +0.40 8

AV6 +0.16 6

AV7 +0.09 9

AV8 +0.05 55 55 55 55 55 55 55 55 55 55 55 14 8

AV3 +0.19 11 AV6 +0.00 14 AV7 +0.05 10 AV8 +0.07 16 9

AV2 -0.14 7

AV3 -0.12 18 AV6 +0.00 9

AV7 +0.05 9

AV8 +0.07 20 8

AV3 -0.07 26 6

AV3 -0.05 34 7

AV3 -0.09 7

AV6 +0.21 38 6

AV3 -0.10 108 7 AV6 +0.22 112 7 AV6 +0.13 116 7 AV6 +0.05 118 7 AV3 +0.08 120 8 AV3 -0.18 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 55 122 6 AV6 +0.18 55 55 55 55 55 55 55 55 55 6

128 6 130 6 134 7 142 10 144 8 148 7 154 6 12 7

156 11 8

9 158 7 AV7 +0.07 AV3 -0.14 AV6 +0.23 AV6 +0.17 AV6 +0.26 AV3 +0. 35 AV6 +0.21 AV1 +0.22 AV3 -0.09 AV6 +0.21 AV7 +0.16 AV6 +0.14 AV1 -0.02 AV3 +0.11 10 AV6 +0.02 15 AV7 +0.18 55 160 12 AV7 -0.05 14 AV6 -0.33 5

. AV3 -0.41 13 AV2 -0.26 11 AV1 +0.16 56 9

10 AV3 -0.18 11 AV7 +0.25 6

AV8 +0.25 56 11 7

AV1 -0.09 11 AV2 -0.09 12 AV3 +0.35 15 AV7 +0.23 9

AV8 +0.23 6

AV6 +0.27 56 13 7

AV3 -0.05 8

AV6 +0.20 8

AV8 +0.05 56 15 6

AV3 +0.21 6

AV6 +0.21 7

AV7 +0.21 7

AV8 -0.14 56 17 8

AV2 +0.12 7

AV3 +0.19 14 AV6 +0.02 7

9 56 19 6

56 25 6

56 33 8

56 35 8

56 43 6

AV7 +0.02 AV8 +0.07 AV3 -0.05 AV3 +0.32 AV6 +0.18 AV3 +0.37 AV3 -0.11 AV6 -0.13 AV3 +0.11 AV6 +0. 02 AV2 +0.05 AV3 +0.11 6

56 107 7 56 111 8 56 113 8 56 121 6 56 56 56 56 56 56 56 56 56 56 56 9

AV6 +0.02 6

AV7 +0.04 123 6 AV3 -0.45 7

AV6 +0.02 125 6 AV2 +0.07 127 7 AV6 +0.16 137 9 AV6 +0.05 11 AV7 +0.07 139 7 AV7 +0.04 143 14 AV3 +0.08 6

AV6 +0.21 147 12 AV6 -0.21 9

AV7 -0.18 149 8 AV3 +0.24 10 AV6 -0.05 153 6 AV6 -0.05 11 AV3 +0.19 155 7 AV8 -0.18 157 7 AV6 +0.18 L-2019-064 Enclosure Page 19 of 89 Page 3 of 32 ROW COL %TW LOCATION 5

AV1 -0.02 56 159 5 AV8 +0.17 11 AV7 +0.18 14 AV2 -0.21 10 AV1 -0.20 56 161 12 AV7 -0.23 17 AV6 +0.18 8

AV2 +0.16 57 10 7

AV1 -0.18 11 AV2 -0.12 7

AV3 -0.21 10 AV6 +0.26 9

AV7 +0.24 57 12 8

AV3 +0.42 7

AV6 +0.02 8

AV8 +0.05 57 14 8

9 7

57 18 7

AV2 +0.07 AV3 +0.11 AV6 -0.05 AV2 -0.05 7

AV3 -0.07 5

AV8 +0.16 57 20 10 AV3 -0.10 57 22 7

AV3 +0.00 57 28 7

AV3 -0.05 57 100 7 AV3 +0.00 8

AV6 +0.21 57 102 9 AV6 +0.21 57 104 6 AV6 +0.07 57 108 8 AV6 +0.20 57 110 5 AV7 +0.13 57 112 6 AV6 +0.09 57 116 8 AV3 +0.08 19 AV6 +0.02 57 120 9 AV3 -0.12 7

57 124 5 57 126 8 8

57 128 7 5

AV6 +0. 02 AV6 +0.21 AV6 +0. 09 AV7 +0.05 AV3 +0.03 AV6 +0.22 57 136 10 AV6 +0.00 7

AV7 +0.02 57 138 8 AV3 +0.11 11 AV6 +0. 00 57 142 11 AV6 +0.23 7

AV7 +0.00 57 144 6 AV3 +0.29 57 148 10 AV6 +0.17 57 154 8 AV6 +0.14 14 AV3 -0.23 8

AV1 -0.25 57 156 5 AV8 -0.25 57 57 58 58 11 7

9 158 13 14 9

7 160 13 12 13 9

8 8

9 12 13 16 9

11 9

14 AV7 +0.15 AV6 +0.14 AV1 +0.14 AV2 +0.00 AV3 +0.26 AV7 +0.16 AV8 -0.13 AV7 -0.05 AV6 -0.35 AV3 +0.21 AV2 -0.25 AV1 -0.27 AV6 +0.14 AV3 -0.16 AV6 +0.27 AV7 -0.16 AV8 +0.27 AV1 -0.14 AV2 -0.16

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 9

AV3 +0.27 17 AV6 +0. 02 14 AV8 -0.09 58 13 6

AV1 +0.07 7

AV3 -0.10 12 AV6 +0.00 7

AV7 +0.05 58 15 6

AV1 +0.21 7

AV2 +0.22 7

AV7 +0.02 5

AV8 -0.12 58 17 11 AV3 -0.07 6

58 19 8

7 7

58 25 5

58 35 8

8 58 43 6

58 73 6

58 75 7

7 58 101 5 58 109 6 58 113 5 8

58 115 8 58 117 7 58 119 6 58 121 6 58 125 5 58 58 58 58 58 58 58 58 58 58 58 58 58 58 6

7 127 6 129 8 7

131 7 133 8 137 9 141 9 145 9 7

8 147 10 7

6 151 10 7

153 8 7

7 155 8 12 6

7 157 6 7

8 9

159 7 9

15 10 161 12 18 10 AV8 -0.09 AV6 +0. 00 AV7 +0.00 AV8 +0.05 AV3 -0.02 AV3 +0. 38 AV6 -0.23 AV6 -0.18 AV6 +0.02 AV6 +0.05 AV7 +0. 05 AV6 +0.18 AV6 +0.11 AV2 +0.07 AV7 +0.00 AV3 +0. 05 AV2 +0.12 AV3 -0.18 AV6 +0.02 AV2 +0.07 AV3 +0.10 AV6 +0.02 AV6 +0.16 AV2 +0.12 AV3 +0.13 AV6 +0.02 AV6 +0.02 AV3 +0.10 AV7 +0.21 AV1 +0.12 AV3 +0. 32 AV6 +0.02 AV3 +0.16 AV6 +0.05 AV7 -0.19 AV7 -0.05 AV1 -0.23 AV6 +0.18 AV3 +0.00 AV1 -0.20 AV8 -0.18 AV6 -0.05 AV2 -0.02 AV1 -0.23 AV6 +0.16 AV3 -0.25 AV2 -0.21 AV1 -0.25 AV7 +0.14 AV6 +0.16 AV3 +0.19 AV1 -0.22 AV7 -0.23 AV6 +0.16 AV6 -0.37 8

AV3 -0.27 59 10 7

AV1 -0.12 11 AV2 -0.12 14 AV3 -0.16 9

AV6 +0.21 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 8

AV7 +0.23 13 AV8 +0.21 59 12 9

AV1 +0.05 7

AV2 -0.09 14 AV3 +0.41 18 AV6 -0.16 16 AV7 -0.18 12 AV8 -0.11 59 14 7

AV2 +0.12 11 AV3 +0.18 13 AV6 +0.00 11 AV7 +0. 02 9

AV8 -0.14 59 16 6

AV1 +0.12 18 AV6 +0.02 59 18 8

AV3 -0.07 59 20 10 AV3 -0.02 59 22 6

AV8 +0.12 59 24 6

AV2 +0.12 7

AV3 +0.15 59 26 5

AV2 +0.12 59 34 6

AV3 -0.10 5

AV6 +0.21 59 44 7

AV3 -0.15 59 58 7

AV6 +0.05 59 68 7

AV2 +0.07 10 AV3 +0.10 10 AV6 +0.00 9

AV7 +0. 02 59 76 5

AV6 -0.47 59 84 11 AV6 +0.05 14 AV7 +0. 02 9

AV8 -0.02 100 6 AV6 +0.21 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 59 102 7 AV3 +0.03 10 AV6 +0.20 104 9 AV6 +0.05 8

AV3 +0.15 106 7 AV3 +0.11 9

AV6 +0.05 108 10 AV3 +0.10 8

AV6 +0.07 110 10 AV2 +0.12 16 AV3 +0.03 16 AV6 +0.05 116 8 AV6 +0.05 118 6 AV3 +0.05 120 8 AV3 -0.05 124 6 AV6 +0.07 128 6 AV6 +0.21 132 6 AV7 +0.20 140 9 AV2 +0.13 142 10 AV2 +0.10 8

AV6 +0.00 144 7 AV2 -0.48 148 6 AV1 +0.12 8

AV2 +0.28 6

AV3 +0.15 8

AV6 -0.03 150 13 AV3 -0.05 8

AV2 +0.00 152 9 AV6 -0.11 8

AV3 -0.02 8

AV2 -0.07 6

AV1 -0.23 154 7 AV1 -0.09 11 AV3 -0.02 7

AV6 +0.21 59 156 11 AV8 -0.23 12 AV7 +0.16 15 AV6 -0.08 7

AV1 -0.05 L-2019-064 Enclosure Page 20 of89 Page 4 of 32 ROW COL %TW LOCATION 59 160 7 AV8 +0.17 10 AV7 -0.28 8

AV3 +0.24 14 AV2 +0.16 60 11 6

AV1 -0.12 10 AV2 -0.12 12 AV3 +0.34 18 AV6 +0. 02 15 AV7 +0.05 11 AV8 +0.26 60 13 8

AV2 -0.10 5

AV3 -0.07 13 AV6 +0. 02 8

AV8 +0.02 60 15 7

AV3 +0.38 11 AV6 -0.15 60 17 8

AV2 -0.12 7

AV3 -0.02 6

AV8 -0.12 60 21 8

AV6 -0.13 60 31 11 AV6 -0.03 7

AV7 +0.02 60 33 8

AV6 +0.05 60 53 8

AV6 +0.05 60 61 11 AV6 +0.04 60 67 9

AV3 +0.18 6

AV6 +0.36 7

AV7 +0.09 60 103 6 AV2 +0.07 6

AV3 +0.10 60 109 10 AV3 +0.03 8

AV6 +0.05 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 9

111 6 121 6 10 123 7 127 9 129 8 7

135 8 13 12 137 12 14 141 15 9

8 145 6 7

147 8 149 8 151 8 153 11 12 12 155 6 7

157 8 14 6

159 8 11 11 15 8

14 AV7 +0.02 AV6 +0.04 AV3 +0.18 AV6 +0. 02 AV6 +0.02 AV6 +0.07 AV6 -0.18 AV7 +0. 07 AV3 +0.13 AV6 +0. 00 AV7 +0.04 AV6 +0.00 AV7 +0.02 AV6 -0.03 AV7 +0.07 AV8 +0.19 AV7 +0. 02 AV8 +0.02 AV6 +0.19 AV6 -0.05 AV3 -0.05 AV8 -0. 05 AV7 -0.07 AV3 -0.02 AV7 +0.14 AV1 -0.25 AV8 +0.17 AV3 -0.07 AV1 -0.02 AV8 +0.17 AV7 +0.14 AV6 +0.16 AV3 +0.21 AV2 -0.21 AV1 -0.20 61 10 5

AV2 -0.09 12 AV3 -0.19 18 AV6 +0.23 7

AV7 +0.23 11 AV8 +0.21

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 61 12 8

AV3 +0.31 6

AV6 -0.21 61 14 7

AV2 -0.09 7

AV3 -0.05 8

AV6 +0.00 10 AV7 +0.02 11 AV8 +0.05 61 16 10 AV3 -0.10 16 AV6 +0.04 61 18 6

AV3 +0.43 14 AV6 -0.03 12 AV7 +0. 05 61 20 6

AV3 -0.05 11 AV6 +0.02 7

AV7 +0.02 61 22 12 AV3 -0.10 6

AV6 -0.03 61 28 5

AV2 -0.07 61 30 7

AV3 +0.17 5

AV6 +0.00 61 32 5

AV3 +0.38 61 34 9

AV3 -0.05 6

AV6 +0.21 61 38 10 AV6 +0.00 8

AV7 +0.02 61 44 6

AV3 -0.12 61 48 5

AV3 -0.05 61 50 7

AV3 +0.10 61 60 7

AV3 +0.10 7

AV6 +0.07 61 102 10 AV3 +0.13 17 AV6 +0.07 61 104 7 AV2 +0.02 7

AV3 +0.23 9

AV6 +0.05 61 106 9 AV6 +0.09 61 108 7 AV2 +0.05 9

AV3 +0.10 8

AV6 +0.05 61 110 8 AV3 +0.03 7

AV6 +0.02 61 112 12 AV3 +0.05 6

AV6 +0.25 61 114 7 AV2 +0.05 10 AV3 +0.00 10 AV6 +0.05 61 116 8 AV2 +0.09 15 AV3 +0.05 9

AV7 +0.07 61 118 8 AV6 +0.05 61 126 6 AV3 +0.08 6

AV6 +0.23 61 130 8 AV3 +0.18 15 AV6 +0.02 9

AV7 +0.07 61 134 7 AV6 +0.10 6

AV7 +0.18 61 140 8 AV6 +0.16 61 142 6 AV2 +0.26 17 AV6 +0.00 61 146 7 AV3 +0.13 9

AV6 -0.18 61 152 7 AV8 -0.23 11 AV6 -0.21 9

AV3 -0.05 61 154 6 AV3 +0.34 11 AV6 +0. 02 7

AV7 +0.02 7

AV8 +0.07 61 156 13 AV7 +0.14 12 AV3 +0.13 12 AV2 -0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 12 AV1 -0.02 61 158 9 AV2 -0.05 14 AV3 +0.48 9

AV6 +0. 00 14 AV7 +0.20 61 160 8 AV6 -0.05 11 AV3 -0.30 13 AV7 -0.25 62 11 10 AV1 -0.12 13 AV2 +0.30 15 AV3 +0.33 10 AV6 +0.38 10 AV8 +0.23 14 AV7 -0.18 62 13 9

AV8 +0.21 6

AV1 +0.07 7

AV2 -0.40 13 AV3 -0.. 02 19 AV6 +0.02 11 AV7 +0. 07 62 15 18 AV6 +0.00 11 AV7 +0.02 7

AV8 +0.07 62 17 6

AV2 +0.28 7

AV3 -0.07 62 19 5

AV1 -0.29 7

AV3 +0.18 62 23 6

AV1 -0.12 7

AV2 +0.07 62 25 6

AV3 -0.07 62 31 6

AV3 -0.02 62 35 7

AV3 +0.30 8

AV6 -0.15 62 59 10 AV3 +0.05 12 AV6 +0.05 15 AV7 +0. 02 62 61 7

AV6 +0.07 6

AV7 +0.07 62 65 10 AV6 +0.09 62 73 9

AV3 +0.08 11 AV6 +0. 05 7

AV7 +0.07 62 97 7

AV6 +0.02 62 99 5

AV6 +0.27 62 103 6 AV3 +0.05 7

AV6 +0.07 62 105 9 AV3 +0.20 9

AV7 +0.04 62 107 12 AV3 +0.13 62 109 11 AV2 +0.07 13 AV3 +0.05 9

AV6 +0.09 62 111 10 AV6 +0.00 62 113 7 AV6 +0.02 12 AV7 +0.00 7

AV2 +0.07 8

AV3 +0.13 62 115 6 AV3 +0.00 6

AV6 +0.05 6

AV7 +0.00 62 117 9 AV3 +0.03 62 119 6 AV3 -0.17 62 121 12 AV6 +0.00 62 129 6 AV6 -0.18 62 131 12 AV6 +0.00 62 139 8 AV2 -0.07 62 143 8 AV6 +0.14 10 AV7 +0.05 62 151 10 AV3 -0.05 8

AV1 -0.05 62 153 16 AV8 -0.02 16 AV7 -0.05 L-2019-064 Enclosure Page 21 of 89 Page 5 of 32 ROW COL %TW LOCATION 17 AV6 -0.05 17 AV3 +0.00 62 155 6 AV7 +0.14 62 157 15 AV8 +0.16 11 AV7 +0.11 15 AV6 -0.08 11 AV3 -0.02 7

AV2 -0.21 9

AV1 -0.02 62 159 10 AV8 +0.14 9

AV3 +0.15 11 AV2 +0.16 12 AV1 -0.22 63 12 9

AV1 +0.07 12 AV2 +0.09 7

AV7 +0.21 63 14 6

AV1 +0.07 7

AV2 -0.12 9

AV3 -0.09 7

AV6 -0.21 7

AV7 +0.18 5

AV8 +0.21 63 16 7

AV2 -0.02 14 AV3 +0.15 7

AV6 +0.23 5

AV7 -0.07 10 AV8 +0.18 63 18 6

AV7 +0.14 10 AV8 +0.05 9

AV3 +0.48 63 34 10 AV3 +0.15 14 AV6 +0.05 63 38 15 AV6 +0.02 7

AV7 -0.16 6

AV8 +0.07 63 44 7

AV2 +0.10 7

AV3 +0.10 63 46 6

AV6 +0.00 63 58 7

AV3 +0.15 10 AV6 +0.00 63 60 6

AV3 -0.38 7

AV6 +0.05 63 64 10 AV3 +0.13 14 AV6 +0.07 63 74 11 AV6 +0.07 63 76 9

AV3 +0.13 10 AV6 +0.07 63 78 16 AV3 +0.10 8

AV6 +0. 05 63 90 5

AV2 -0.22 63 98 8

AV3 +0.05 5

AV6 +0.25 63 100 13 AV6 +0.05 63 102 6 AV2 +0.10 10 AV6 +0.16 63 104 7 AV2 +0.02 6

AV3 +0.13 16 AV6 +0.07 8

AV7 +0.02 63 106 15 AV3 +0.18 11 AV6 +0.07 63 108 7 AV6 +0.18 63 110 7 AV3 +0.10 15 AV6 +0.05 63 112 7 AV7 +0.02 63 114 10 AV3 +0.03 11 AV7 +0.05 63 116 8 AV6 +0.02 63 118 6 AV6 +0.07 63 128 8 AV6 +0.21 63 130 9 AV6 +0.21 63 132 12 AV3 +0.13

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 14 AV6 +0. 02 63 134 9 AV2 +0.07 9

AV3 +0.10 16 AV6 +0.00 63 136 13 AV6 +0.02 9

AV7 +0.09 63 142 8 AV6 +0.02 63 144 6 AV2 +0.05 15 AV3 +0.10 63 63 63 63 63 19 AV6 +0.00 8

AV7 +0.18 8

AV8 +0.00 146 12 AV3 +0.13 6

AV7 +0. 02 5

AV2 +0. 09 148 6 AV1 -0.11 9

AV3 +0.20 12 AV6 -0.20 150 15 AV3 -0.02 11 AV2 +0.00 7

AV1 +0.14 152 5 AV8 -0.21 5

AV7 +0.11 10 AV6 -0.05 8

AV1 -0.23 154 8 AV1 -0.09 11 AV2 +0. 07 11 AV3 -0.07 9

AV6 +0.03 7

AV8 -0.13 63 156 12 AV8 -0.23 14 AV7 +0.14 15 AV6 -0.05 10 AV2 -0.05 18 AV1 -0.25 64 11 6

AV3 -0.14 11 AV6 +0.23 11 AV7 +0.25 64 13 5

AV1 -0.07 8

AV2 -0.12 16 AV3 +0.13 7

AV8 -0.11 64 15 7

AV3 +0.30 10 AV6 +0.02 64 17 10 AV3 +0.20 18 AV6 +0.02 8

AV7 +0.02 14 AV8 +0.02 64 19 10 AV6 +0.00 64 27 10 AV6 +0.02 64 29 10 AV7 +0.05 64 33 7

AV3 -0.09 17 AV6 +0.05 64 39 7

AV6 +0.00 64 45 6

AV6 +0.02 64 55 7

AV3 +0.02 6

AV6 +0. 02 64 61 7

AV6 +0.05 64 63 6

AV2 +0.05 9

AV3 +0.10 14 AV6 +0.05 64 75 5

AV2 +0.05 10 AV3 +0.10 18 AV6 +0. 09 7

AV7 +0.05 64 87 7

AV2 -0.18 64 91 6

AV2 -0.18 64 93 8

AV6 +0.05 64 97 9

AV6 +0.05 64 99 12 AV3 +0.18 9

AV6 +0.05 64 101 12 AV3 +0.15 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 18 AV6 +0.05 13 AV7 +0.02 64 103 9 AV3 +0.10 7

AV6 +0.00 7

AV7 +0.09 64 105 6 AV3 +0.08 17 AV6 +0.07 6

AV7 +0.05 64 109 7 AV6 +0.09 64 111 10 AV3 +0.05 14 AV6 +0. 00 64 113 6 AV2 +0. 05 64 64 64 64 64 64 64 64 64 9

AV3 +0.05 6

AV6 +0.00 8

AV7 +0.02 115 16 AV3 +0.20 14 AV6 +0.02 117 9 AV3 +0.12 119 6 AV2 +0.09 10 AV3 +0.05 8

AV6 +0.09 121 7 AV6 +0.00 123 7 AV6 +0.02 125 6 AV2 +0.14 133 7 AV6 +0.21 135 13 AV6 +0.00 137 10 AV3 +0.08 13 AV6 +0.02 9

AV7 +0.02 64 143 7 AV3 -0.05 64 145 10 AV1 +0.09 7

5 64 147 7 AV3 +0.15 AV7 -0.35 AV1 +0.24 64 149 10 AV2 +0.07 64 153 6 AV8 -0.18 9

AV6 +0.19 14 AV3 -0.07 64 155 16 AV1 -0.20 8

AV8 -0.02 10 AV7 +0.12 9

AV6 -0.05 7

AV2 +0.11 64 157 7 AV8 +0.19 10 AV7 +0.18 9

AV6 -0.23 9

AV1 +0.16 64 159 7 AV7 -0.23 6

AV6 +0.19 65 12 8

AV1 -0.09 16 AV2 +0.32 12 AV3 +0.25 7

AV8 +0.21 65 14 8

AV1 +0.28 13 AV2 +0.16 19 AV3 +0.20 14 AV6 +0. 02 9

AV7 +0.05 65 16 8

AV2 -0.09 10 AV3 +0.18 13 AV7 +0.02 15 AV8 +0.07 65 18 15 AV6 +0.00 10 AV7 +0.02 65 20 7

AV2 +0.12 8

AV6 +0.05 65 22 8

AV6 +0.02 11 AV7 +0.05 65 34 6

AV6 +0.20 65 42 13 AV6 +0.00 65 44 6

AV3 -0.14 7

AV7 +0.02 L-2019-064 Enclosure Page 22 of89 Page 6 of 32 ROW COL %TW LOCATION 6

AV8 +0.07 65 48 12 AV6 +0.07 65 50 7

AV6 +0.02 7

AV7 +0.02 65 56 6

AV6 +0.11 65 58 11 AV6 +0.05 65 62 7

AV3 +0.12 7

AV6 +0. 05 65 66 7

AV6 +0.07 65 68 6

AV3 +0.08 65 70 6

AV2 -0.09 65 65 65 65 65 65 65 11 AV3 +0.10 11 AV6 +0. 00 13 AV7 +0.02 74 12 10 78 5

84 6

8 7

86 5

AV6 +0.07 AV7 +0.07 AV3 -0.21 AV2 -0.12 AV3 +0.05 AV6 -0.23 AV7 -0.02 94 11 AV6 +0.05 96 11 AV3 +0.18 98 11 AV3 +0.15 65 65 13 AV6 +0.07 100 6 AV6 +0.18 102 6 AV3 +0.10 17 AV6 +0.05 10 AV7 +0. 05 65 104 10 AV3 +0.12 7

AV6 +0. 05 7

AV7 +0.04 65 106 11 AV3 +0.15 10 AV6 +0.07 10 AV7 +0.04 65 108 12 AV3 +0.12 10 AV7 +0.04 65 110 8 AV3 +0.15 15 AV7 +0.05 65 112 8 AV2 +0.10 7

AV3 +0.10 13 AV6 +0.23 10 AV7 +0.04 65 114 7 AV2 +0.10 17 AV3 +0.02 8

AV6 +0.00 65 116 18 AV3 +0.15 17 AV6 +0.02 10 AV7 +0.02 65 118 6 AV2 +0.00 5

AV3 -0.16 9

AV6 +0.00 10 AV7 +0.07 65 120 11 AV3 +0.12 16 AV6 +0.00 10 AV7 +0.02 65 126 6 AV6 +0.23 65 128 12 AV6 +0.02 65 130 9 AV2 +0.09 10 AV3 +0.12 7

AV6 +0.21 65 134 6 AV2 +0.10 12 AV7 +0.11 65 136 11 AV6 +0.02 65 138 9 AV3 +0.22 7

AV6 +0.02 65 144 17 AV6 +0.00 9

AV8 +0.05 65 152 15 AV8 -0.20 65 154 9 AV1 +0.28 15 AV7 +0.04 11 AV8 +0.05

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 65 156 15 AV8 -0.21 5

AV7 +0.16 7

AV6 -0.28 6

AV3 +0.20 8

AV2 +0.14 9

AVl -0.25 65 158 10 AV3 +0.32 19 AV6 -0.18 8

8 66 13 7

AV7 +0.22 AV8 +0.23 AVl +0.30 7

AV3 +0.15 10 AV7 +0.00 66 15 9

AVl +0.07 15 AV2 +0.26 9

AV7 +0.00 11 AV8 +0.07 66 17 8

AV2 +0.30 66 19 7

AV3 +0.13 12 AV6 +0.02 66 21 7

AV3 +0.15 7

AV6 -0.18 66 23 13 AV6 +0.00 66 27 11 AV2 +0.19 66 29 11 AV6 +0.00 66 31 7

AV3 +0.22 13 AV6 +0.00 15 AV7 +0. 05 12 AV8 +0. 05 66 33 6

AV2 +0.14 6

AV3 -0.36 11 AV6 +0.02 66 35 18 AV6 +0.00 66 43 11 AV6 -0.15 7

AV7 +0.00 66 45 6

AV3 +0.17 66 51 7

AV3 +0.15 13 AV6 +0.05 66 53 8

AV3 +0.15 9

AV6 +0.05 66 55 10 AV3 +0.12 9

AV6 +0.05 66 59 8

AV3 +0.12 11 AV6 +0. 05 11 AV7 +0. 05 66 61 13 AV3 +0.15 19 AV6 +0.02 66 75 15 AV6 +0.05 8

AV7 +0.02 66 77 6

AV2 +0.12 6

AV3 +0.07 7

AV6 +0. 05 66 79 5

AV3 +0.07 66 83 6

AV2 -0.02 66 87 7

AV2 -0.20 66 93 8

AV6 +0.07 66 95 5

AV2 +0.07 8

AV3 +0.12 7

AV6 +0.07 10 AV7 +0.00 66 97 14 AV3 +0.10 10 AV6 +0.07 66 99 9

AV2 +0.05 16 AV3 +0.10 14 AV7 +0.07 66 101 7 AV2 +0.05 8

AV3 +0.08 15 AV6 +0.05 66 103 18 AV3 +0.02 12 AV8 +0.05 66 105 8 AV2 +0.07 19 AV3 +0.12 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 9

AV7 +0.02 66 107 10 AV3 +0.08 10 AV6 +0. 05 66 109 7 AV2 +0.09 10 AV6 +0.07 8

AV7 +0.05 7

AV8 +0.10 66 111 10 AV2 +0.00 14 AV3 +0.08 7

AV6 +0. 05 66 113 19 AV3 +0.05 17 AV6 +0.07 66 115 7 AV2 +0.12 12 AV3 +0.03 66 117 5 AVl +0.05 5

AV3 +0.10 11 AV6 +0.05 66 119 6 AV3 -0.05 66 121 17 AV6 +0.02 10 AV7 +0.02 66 123 6 AV3 +0.10 66 129 11 AV6 +0.05 66 131 7 AV3 +0.15 9

AV6 +0. 02 66 135 11 AV6 +0.02 66 137 12 AV6 +0.05 11 AV7 +0.04 11 AV8 +0.07 66 141 7 AV3 +0.13 8

AV6 -0.15 66 143 7 AV3 +0.07 66 145 8 AVl +0.17 7

AV3 +0.15 13 AV6 +0.02 17 AV7 +0.05 16 AV8 +0.02 66 147 9 AV3 +0.10 13 AV6 +0.02 66 149 8 AVl +0.00 10 AV2 +0.03 8

AV3 +0.12 9

AV6 +0.26 66 151 7 AV8 -0.14 66 153 18 AV6 -0.08 66 155 8 AV8 -0.23 7

AV7 -0.02 7

AV6 -0.05 9

AV3 -0.05 10 AVl +0.19 66 157 11 AVl -0.11 14 AV3 +0.13 12 AV6 -0.13 12 AV7 +0.21 13 AV8 +0.29 67 12 10 AV8 +0.27 11 AV6 +0.13 67 14 8

AV2 +0.14 8

AV3 +0.15 9

AV6 -0.20 67 16 5

AVl +0.19 9

AV2 +0. 07 10 AV6 +0.05 11 AV7 +0.00 67 18 6

AVl +0.24 6

AV3 +0.12 67 20 7

AV7 +0.07 12 AV3 +0.17 67 34 8

AV3 +0.15 8

AV6 +0.16 67 38 8

AV2 +0.14 17 AV3 +0.15 13 AV6 +0. 02 ROW COL %TW 9

8 67 40 9

6 67 42 8

67 44 10 17 67 46 9

67 48 7

67 50 16 14 L-2019-064 Enclosure Page 23 of89 Page 7 of 32 LOCATION AV7 -0.11 AV8 +0.05 AV6 +0.00 AV7 -0.02 AV7 +0.05 AV2 +0.12 AV6 +0. 02 AV6 +0.02 AV8 +0.02 AV3 +0.12 AV6 +0. 07 7

AV7 +0. 02 67 52 10 AV3 +0.12 16 AV7 +0. 02 67 54 9

AV6 +0.05 67 58 9

AV6 +0.05 67 62 8

AV6 +0.05 67 64 7

AV3 +0.12 7

AV6 +0.07 67 66 14 AV6 +0.07 67 68 16 AV3 +0.10 10 AV6 +0.05 8

AV7 +0.05 67 70 10 AV3 +0.10 9

AV6 +0.07 67 74 13 AV3 +0.12 67 88 8

AV2 -0.18 67 92 6

AV3 -0.07 6

AV2 -0.21 67 94 8

AV3 -0.09 5

AVl +0.05 9

AV2 +0.05 67 96 5

AV2 +0.05 17 AV3 +0.05 10 AV7 +0.00 67 98 6

AV2 +0.05 9

AV3 +0.15 7

AV6 +0.20 67 100 10 AV3 +0.13 14 AV6 +0.02 6

AV7 +0.05 67 102 9 AV2 +0.09 67 104 16 AV2 +0.02 67 106 5 AV2 +0.07 7

AV3 +0.10 7

AV6 +0.14 11 AV7 +0.04 67 108 9 AV2 +0.10 15 AV3 +0.10 8

AV6 +0.07 67 110 8 AV2 +0.07 19 AV3 +0.08 18 AV6 +0.05 6

AV7 +0.02 67 112 13 AV2 +0.07 10 AV3 +0.05 10 AV6 +0.07 10 AV7 +0.07 67 114 8 AV7 +0.02 67 116 6 AV2 +0.05 8

AV3 +0. 05 10 AV6 +0.02 6

AV7 +0.04 67 118 7 AV2 +0.07 7

AV3 +0.23 6

AV6 +0. 02 8

AV7 +0.07 67 122 7 AV6 +0.23 67 128 9 AV3 +0.03 8

AV7 +0.05 67 130 6 AV3 +0.05 9

AV6 +0.21

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 67 132 8 AV2 +0.07 11 AV3 +0.15 67 134 9 AV6 +0.00 67 138 10 AV6 +0.02 67 140 6 AV1 +0.26 10 AV6 +0. 02 67 142 15 AV2 +0.09 11 AV3 +0.15 7

AV6 +0.24 5

AV8 -0.16 67 144 8 AV1 +0.17 67 146 12 AV1 +0.09 16 AV2 +0.12 14 AV6 +0.00 148 9 AV1 +0.05 67 67 67 67 67 14 AV2 +0.07 12 AV7 +0.02 150 7 AV3 -0.05 152 10 AV7 -0.05 14 AV6 -0.05 8

AV2 -0.05 8

AV1 +0.19 154 11 AV1 +0.28 19 AV2 +0.09 18 AV7 +0. 02 156 13 AV8 -0.23 8

AV6 -0.30 9

AV3 +0.15 12 AV2 -0.05 10 AV1 -0.23 67 158 8 AV1 -0.16 7

AV2 +0.31 16 AV6 -0.23 10 AV7 +0.02 9

AV8 +0.26 68 13 9

AV1 +0.24 10 AV3 +0.18 8

AV6 +0. 02 7

AV7 +0.07 68 15 7

AV1 +0.24 68 17 8

AV1 +0.21 8

AV2 +0.28 7

AV3 +0.23 19 AV6 +0.00 10 AV8 +0.02 68 19 5

AV1 +0.07 68 21 8

AV6 -0.10 68 35 6

AV3 -0.16 6

AV6 -0.16 68 45 7

AV3 +0.09 8

AV6 +0.05 68 55 8

AV3 +0.06 7

AV6 +0.07 68 59 7

AV6 +0.05 9

AV7 +0.00 68 61 8

AV8 +0.02 68 63 11 AV3 +0.15 7

AV6 +0.07 12 AV7 +0.05 68 65 7

AV6 +0.02 68 67 15 AV3 +0.09 12 AV7 +0.07 68 69 7

AV2 +0.10 10 AV3 +0.20 6

AV6 +0. 02 68 71 11 AV2 +0.07 12 AV3 +0.14 68 77 11 AV6 +0.02 8

AV7 +0.00 68 79 6

AV3 +0.14 10 AV6 +0. 07 68 81 7

AV3 +0.09 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 10 AV6 +0.02 68 87 6

AV8 -0.07 7

AV7 -0.02 6

AV3 -0.07 6

AV2 -0.05 68 89 11 AV6 -0.05 68 93 6

AV3 +0.09 68 95 8

AV6 +0.02 68 97 9

AV3 +0.13 10 AV6 +0.04 68 99 14 AV3 +0.07 19 AV6 +0. 07 8

AV7 +0.04 101 6 AV2 +0.07 10 AV3 +0.05 9

AV7 +0.02 103 6 AV2 +0.02 68 68 68 68 68 13 AV3 +0.00 14 AV7 +0.09 105 7 AV1 +0.12 8

AV2 +0.15 15 AV3 +0.14 9

AV6 +0.09 107 11 AV2 +0.07 9

AV3 +0.17 9

AV6 +0. 05 109 6 AV6 +0.04 7

AV7 +0.05 68 111 15 AV3 +0.11 68 113 8 AV6 +0.02 11 AV7 +0.04 68 115 6 AV2 +0.12 17 AV3 +0.04 8

AV8 +0.05 68 117 6 AV1 +0.07 7

AV3 +0.09 15 AV7 +0.05 68 119 10 AV6 +0.05 68 121 18 AV6 +0.02 68 123 10 AV6 +0.05 10 AV7 +0. 07 68 125 8 AV6 +0.07 10 AV7 +0.04 68 133 6 AV2 +0.10 6

AV3 +0.16 68 135 10 AV2 +0.05 15 AV3 +0.16 15 AV6 +0. 02 7

AV7 +0. 02 68 139 7 AV3 +0.19 68 143 6 AV1 +0.30 7

AV6 +0.24 68 145 15 AV3 +0.07 7

AV6 +0. 02 6

AV7 +0.07 68 147 7 AV3 +0.16 68 149 10 AV7 +0.04 68 151 10 AV6 +0.05 68 153 7 AV8 -0.18 14 AV7 -0.07 12 AV6 -0.05 14 AV3 -0.02 9

AV1 +0.16 68 155 9 AV1 -0.05 68 157 10 AV1 -0.16 17 AV3 +0.17 69 14 9

AV1 -0.14 11 AV2 +0. 07 9

AV3 +0.36 10 AV6 -0.15 69 18 7

AV2 +0.26 7

AV3 +0.38 L-2019-064 Enclosure Page 24 of89 Page 8 of 32 ROW COL %TW LOCATION 7

AV6 -0.17 69 36 7

AV3 +0.43 69 56 14 AV3 +0.14 69 60 7

AV7 +0.00 69 62 7

AV6 +0.02 69 66 14 AV3 +0.12 13 AV6 +0.11 69 68 8

AV2 +0.07 10 AV3 +0.09 7

AV6 +0.07 69 70 7

AV3 +0.17 13 AV6 +0.00 69 72 6

AV3 +0.06 69 69 69 69 69 69 9

9 74 11 15 16 12 76 6

8 86 7

88 15 17 90 7

8 92 7

6 AV6 +0. 05 AV7 +0.00 AV2 +0.05 AV3 +0.11 AV6 +0.05 AV7 +0.05 AV3 +0.14 AV6 +0. 05 AV6 -0.04 AV7 -0.05 AV3 -0.05 AV6 -0.02 AV2 -0.18 AV6 -0.04 AV3 -0.07 69 94 10 AV6 +0.05 69 96 10 AV3 +0.03 9

AV6 +0. 05 69 98 11 AV2 +0.08 12 AV3 +0.06 12 AV6 +0.07 10 AV7 +0. 02 69 100 18 AV7 +0.05 7

AV2 +0. 07 13 AV3 +0.12 69 102 10 AV2 +0.07 10 AV3 +0.06 13 AV6 +0. 07 9

AV7 -0.02 69 104 19 AV2 +0.07 15 AV3 +0.09 69 106 6 AV2 +0.09 14 AV3 +0.06 12 AV7 +0.07 69 108 6 AV2 +0.05 8

AV8 +0.05 69 110 13 AV6 +0.02 5

AV7 +0.07 69 112 11 AV6 +0.20 5

AV7 +0.07 69 114 9 AV1 +0.05 6

AV2 +0.09 8

AV3 +0.03 6

AV6 -0.02 5

AV7 +0. 05 7

AV8 +0.05 69 116 11 AV3 +0.09 15 AV6 +0.05 69 118 5 AV2 +0.02 6

AV6 +0.00 69 120 6 AV3 +0.00 8

AV7 +0.02 69 122 5 AV3 +0.09 5

AV6 -0.17 69 124 7 AV3 +0.06 5

AV6 +0.12 69 134 8 AV3 +0.17 12 AV6 +0.00 69 136 8 AV6 +0.02

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 69 138 7 AV6 +0.05 69 140 5 AV1 +0.08 7

AV7 -0.07 4

69 146 8 AV8 +0.21 AV1 +0. 02 7

AV2 +0.07 6

AV6 +0.00 69 150 9 AV2 +0.00 69 152 10 AV8 -0.21 11 AV7 -0.07 15 AV6 -0.17 6

AV3 +0.20 7

AV1 +0.00 69 154 13 AV1 +0.31 11 AV2 +0.09 16 AV3 +0.12 14 AV8 +0.05 70 13 7

AV6 +0.21 70 15 10 AV1 +0.05 8

AV2 -0.12 9

AV6 +0.05 18 AV7 +0.02 13 AV8 +0.05 70 17 7

AV1 +0.26 9

AV2 +0.21 7

AV8 +0.25 70 35 5

AV4 -0.12 5

AV6 -0.12 70 45 7

AV5 -0.59 70 53 7

AV6 +0.07 9

AV7 +0.02 70 57 6

AV6 +0.18 70 59 7

AV6 +0.05 70 63 8

AV3 +0.06 12 AV6 +0.07 70 65 9

AV2 +0.09 13 AV3 +0.06 70 67 10 AV6 +0.00 9

AV7 +0.07 70 69 14 AV6 +0.05 10 AV7 +0.07 70 71 15 AV6 +0.05 8

AV7 +0.09 70 73 14 AV6 +0.05 9

AV7 +0.07 70 75 9

AV2 +0.07 7

AV3 +0.08 9

AVS -0.43 9

AV6 +0.07 10 AV7 +0.02 6

AV8 +0.05 70 77 11 AV3 +0.10 9

AV6 +0. 05 70 79 8

AV6 +0.05 70 83 6

AV2 -0.07 70 85 9

AV3 +0.04 10 AV6 +0.05 70 87 14 AV7 -0.05 8

AV5 -0.43 14 AV3 -0.05 6

AV2 -0.27 8

AV4 -0.06 70 91 12 AV7 -0.07 15 AV6 -0.02 16 AV3 -0.02 9

AV2 -0.02 70 93 8

AV3 +0.06 8

AV6 +0.05 70 95 12 AV2 +0.07 13 AV3 +0.09 7

AV6 +0.05 70 97 17 AV3 +0.04 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 19 AV6 +0. 07 15 AV7 +0.02 70 99 8

AV1 +0.09 12 AV2 +0.09 16 AV3 +0.08 7

AVS +0.06 10 AV6 +0.07 13 AV7 +0.02 8

AV8 +0. 02 70 101 7 AV1 +0.09 14 AV2 +0.09 70 103 13 AV2 +0.14 13 AV3 +0.07 9

AV5 +0.27 16 AV6 +0.09 11 AV8 +0.05 70 105 6 AV1 +0.09 10 AV2 +0.05 13 AV6 +0.07 11 AV8 +0.05 70 107 8 AV2 +0.02 5

AV3 +0.06 14 AV6 +0.02 70 109 10 AV2 +0.10 18 AV3 +0.07 7

AV5 +0.07 16 AV8 +0.02 70 111 12 AV6 +0.07 6

AV2 +0.07 70 113 13 AV2 +0.07 5

AV3 +0.04 19 AV6 +0.02 13 AV7 +0.02 70 115 10 AV2 +0.07 7

AV3 +0.04 70 117 9 AV2 +0.17 11 AV3 +0.09 7

AV6 +0.00 12 AV7 +0.02 70 119 5 AV2 +0.07 7

AV6 +0.05 70 121 7 AV2 +0.09 9

AV3 +0.00 8

AV6 +0.02 70 123 8 AV3 +0.04 14 AV6 +0.05 70 129 9 AV6 -0.13 70 133 8 AV2 +0.08 12 AV6 +0.02 8

AV7 +0.07 70 135 5 AV6 +0.05 70 151 7 AV1 +0.21 9

AV7 +0.02 7

AV8 -0.13 70 153 7 AV8 -0.20 9

AV7 -0.16 8

AV6 -0.15 11 AV3 +0.07 9

AV1 +0.19 70 155 17 AV7 -0.12 14 AV6 -0.11 70 157 6 AV3 -0.05 6

AV6 +0.19 71 14 9

AV1 -0.10 11 AV2 +0.14 19 AV3 +0.20 14 AV6 -0.14 7

AV8 +0.25 71 16 6

AVl +0.05 7

AV3 +0.10 15 AV7 +0.05 6

AV8 +0.18 L-2019-064 Enclosure Page 25 of 89 Page 9 of 32 ROW COL %TW LOCATION 71 18 7

AV4 +0.59 71 20 6

AV3 -0.05 71 26 5

AV7 -0.16 71 34 14 AV3 +0.02 71 40 6

AV3 +0.04 71 44 6

71 50 8

71 62 5

71 66 6

AVS +0.27 AV3 +0.04 AV2 +0.28 AVS -0.54 16 AV6 +0.07 71 70 9

AVS +0.00 14 AV6 +0. 00 10 AV7 +0.05 71 72 8

AV4 +0.58 8

AV5 -0.29 17 AV6 +0.07 12 AV7 +0. 02 71 74 7

AV3 +0.04 9

AV4 +0.21 8

AV5 +0.00 15 AV6 +0.05 17 AV7 +0.05 7

AV8 +0.05 71 76 8

AV3 +0.02 9

AV4 +0.54 14 AVS -0.04 12 AV8 +0.05 71 78 10 AV2 +0.07 15 AV3 +0. 06 7

AV4 +0.46 9

AVS -0.21 8

AV7 +0.07 71 80 9

AV6 +0.00 71 84 5

AV3 +0.04 8

AV4 +0.08 71 88 11 AV7 -0.05 12 AV6 -0.04 10 AVS -0.42 12 AV4 -0.06 7

AV2 -0.18 71 90 8

AV7 -0.02 6

AV5 -0.04 71 92 11 AV6 -0.02 11 AV4 -0.02 7

AV3 -0.05 7

AV2 +0. 00 71 94 5

AV3 -0.15 10 AV5 +0.00 71 96 14 AV2 +0.12 8

AV3 +0.09 12 AV6 +0.05 10 AV7 +0. 07 71 98 9

AV2 +0.07 12 AV3 +0.06 15 AV4 +0.25 14 AV6 +0.05 8

AV7 +0.05 71 100 5 AV2 +0.07 12 AV3 +0.06 9

AV4 +0.25 10 AV6 +0.05 14 AV7 +0.05 71 102 10 AV1 +0.07 17 AV2 +0.00 10 AV5 +0.00 16 AV6 +0.07 9

AV7 +0.07 71 104 8 AV3 +0.06 14 AV5 -0.13 14 AV7 +0. 02 71 106 7 7

AV4 +0.54 AV5 -0.55

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 7

AV6 +0.14 8

AV7 +0.09 71 108 10 AV2 +0.10 8

AV5 -0.08 17 AV6 +0.05 17 AV7 +0.05 71 110 8 AV3 +0.08 71 112 9 AV2 +0.10 71 71 71 71 71 71 10 11 9

114 8 12 9

116 10 10 18 14 19 118 7 12 12 120 7 138 9 144 7 AV3 +0.08 AV4 -0.02 AVS -0.58 AV4 -0.02 AV6 +0. 02 AVS +0.06 AV1 +0. 07 AV2 +0.10 AV3 +0.10 AV4 +0.47 AVS -0.13 AV4 +0.47 AV6 +0. 05 AV7 +0. 07 AV6 +0. 00 AV3 +0.16 AV3 +0.21 71 148 7 AV1 +0.14 6

AV8 +0.24 71 150 8 AV1 +0.19 71 152 11 AV8 -0.05 8

AV7 -0.07 9

AV6 -0.17 7

AV1 +0.16 71 154 9 AV1 +0.34 9

AV2 +0.14 8

AV8 +0.26 71 156 10 AV8 +0.17 72 15 9

AV1 +0.05 10 AV2 +0.05 7

AV3 +0.28 19 AV4 +0.49 14 AVS -0.24 14 AV6 -0.15 14 AV7 +0.00 72 17 6

AV1 +0.09 9

AV2 +0.26 6

AV4 +0.45 8

AVS +0.24 72 25 16 AV3 +0.15 12 AV4 +0. 32 15 AVS +0.02 16 AV6 +0. 05 72 29 7

AV7 +0. 07 72 31 5

AV8 +0.07 72 33 8

AV3 +0.17 7

AV4 +0.39 72 35 11 AV4 -0.16 6

AV5 +0.17 6

AV6 -0.17 72 37 6

AV7 +0.18 72 41 5

AV2 +0.34 72 53 11 AV7 +0.02 7

AV6 +0.09 72 61 6

AV6 +0.05 9

AV7 +0.07 72 63 11 AV6 +0.05 72 65 8

AV3 +0.11 72 67 18 AV4 +0.21 17 AV7 +0.07 72 69 6

AV2 +0.05 7

AV3 +0.11 5

AV6 +0.23 10 AV7 +0.07 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 72 71 7

AV2 +0.07 14 AV3 +0.05 15 AV4 +0.17 9

AVS +0.04 9

72 73 9

AV8 +0.02 AV7 +0. 02 72 75 72 77 72 79 6

AV2 +0.09 10 AV3 +0.08 13 AV4 +0.10 13 AVS +0. 02 17 AV6 +0.07 5

AV1 +0.07 8

AV2 +0.09 9

AV3 +0.06 8

AV4 +0.03 14 AV5 +0.06 16 AV8 +0.05 9

AV2 +0.12 5

AV3 +0.00 8

AV4 +0.10 16 AVS +0.02 16 AV6 +0.05 13 AV7 +0.00 15 AV2 +0.02 17 AV4 +0.07 15 AVS +0.08 72 81 6

AV5 -0.25 72 83 7

AV3 +0.09 72 85 7

AV3 +0.15 8

AV4 +0.33 6

AVS -0.33 5

AV6 +0.18 72 87 8

AV5 -0.03 72 89 19 AV6 -0.02 10 AVS +0.04 14 AV3 -0.07 72 91 12 AV8 -0.02 15 AV7 -0.05 18 AVS +0.06 14 AV4 -0.04 9

AV2 -0.02 72 93 16 AV3 +0.04 15 AVS +0.10 72 95 11 AV4 +0.36 8

AVS +0.08 13 AV6 +0.05 7

AV3 +0.04 72 97 8

AV2 +0.05 7

AV3 +0.06 9

AV6 +0.05 72 99 10 AV2 +0.05 8

AV3 +0.04 10 AV6 +0.07 72 101 13 AV4 +0.07 12 AV7 +0.05 8

AV2 +0.05 9

AV3 +0.04 72 103 12 AV2 +0.07 14 AV4 +0.19 10 AV8 +0.05 72 105 8 AV2 +0.00 17 AV4 +0.11 8

AV6 +0.05 7

AV7 +0.05 72 107 12 AV4 +0.22 12 AV5 +0.06 72 109 10 AV2 +0.02 17 AV3 +0.04 10 AV4 +0.19 13 AV7 +0.02 72 111 11 AV2 +0.07 10 AV3 +0.08 L-2019-064 Enclosure Page 26 of 89 Page 10 of 32 ROW COL %TW LOCATION 9

AV4 +0.22 9

AV6 +0.07 8

AV7 +0.07 72 113 15 AV6 +0.02 11 AV7 +0. 02 72 117 8 AV2 +0.07 6

AVS +0.32 72 119 6 AV2 +0.02 72 72 72 72 72 72 72 72 72 7

5 129 7 139 8 141 7 7

145 8 147 4 149 15 10 151 11 8

11 8

153 8 11 155 10 AV3 -0.07 AV6 +0. 07 AV2 +0.00 AVS +0. 00 AV3 +0.08 AV7 +0.20 AV8 -0.14 AV6 +0.16 AV6 -0. 02 AV7 +0. 02 AV3 +0.15 AVS -0.08 AV6 +0. 05 AV7 +0.00 AV3 +0.08 AV1 -0.25 AV1 -0.18 6

AV3 +0.21 9

AV5 +0.24 13 AV7 -0.09 73 16 6

AV1 +0.07 10 AV2 -0.12 13 AV3 +0.07 6

AV8 +0.20 73 18 10 AV1 +0.33 10 AV2 +0.33 18 AV6 +0. 00 18 AV7 +0.05 16 AV8 +0.05 73 44 6

AV4 -0.18 9

AVS +0.24 5

AV8 +0.07 73 48 7

AV4 +0.27 73 54 7

AV3 +0.09 9

AV4 +0.00 7

AV5 +0.09 7

AV6 +0.02 8

AV7 +0.00 73 60 7

AV6 +0.02 8

AV7 +0.02 73 62 8

AV3 +0.09 10 AV4 +0.06 9

AV5 -0.10 9

AV6 +0. 02 73 64 7

AV2 +0.12 73 66 8

AV4 +0.22 15 AV6 +0.09 73 68 11 AV4 +0.25 19 AVS +0.07 73 70 8

AV3 +0.07 9

AVS +0. 07 8

AV6 +0.05 7

AV7 +0.05 73 72 12 AVS -0.19 17 AV6 +0.07 73 74 7

AV2 +0.09 15 AV3 +0.09 14 AV8 +0.05 73 76 12 AV1 +0.14 11 AV2 +0.14 10 AV8 +0.07 73 78 7

AV3 +0.11 9

AV4 +0.10 10 AVS -0.10

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 8

AV6 +0. 07 73 80 5

AV3 -0.14 5

AV5 -0.15 8

AV6 +0. 02 73 82 7

AV3 +0.11 8

AV4 +0.28 10 AV5 +0. 02 13 AV6 +0. 07 13 AV7 +0.02 73 84 9

AV3 +0.09 12 AV4 +0.00 8

AV5 -0.13 7

AV7 +0.07 73 86 7

AV6 -0.09 13 AV4 -0.11 73 88 17 AV4 -0.09 7

AV2 -0.20 73 90 11 AV7 -0.05 8

AV6 -0.02 11 AV5 +0.02 8

AV2 -0.05 73 92 9

AV3 -0.05 7

AV2 -0.05 12 AV6 -0.02 13 AV5 -0.03 18 AV4 +0.10 73 94 10 AV2 +0.07 11 AV3 +0. 07 15 AV4 -0.02 10 AV7 +0.02 73 96 7

AV3 +0.06 15 AV7 +0.04 73 98 10 AV2 +0.12 16 AV4 +0.03 17 AV6 +0.05 13 AV7 +0.07 73 102 9 AV2 +0.05 11 AV3 +0.09 73 104 13 AV2 +0.05 16 AV3 +0.04 17 AV4 +0.23 6

AV7 +0.04 73 106 11 AV1 +0.07 19 AV2 +0.05 19 AV4 +0.00 12 AV5 -0.10 6

AV6 +0.07 9

AV7 +0.09 7

AV8 +0.10 73 108 7 AV2 +0.07 19 AV4 +0.00 8

AV5 +0.07 16 AV6 +0. 02 8

AV7 +0.04 73 110 15 AV5 +0.09 9

AV8 +0.07 73 112 6 AV1 +0.02 5

AV2 +0.07 16 AV4 +0. 03 8

AV5 +0.09 73 114 6 AV5 -0.17 73 116 10 AV4 +0.26 7

AV6 +0.02 73 118 5 AV2 +0.27 8

AV3 +0.11 73 120 7 AV3 +0.02 73 134 7 AV5 +0.16 11 AV6 +0.09 6

AV7 +0. 02 8

AV3 +0.09 73 136 7 73 138 6 AV3 +0.24 AV7 +0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 73 140 7 AV3 +0.09 6

AV6 +0.09 7

AV8 +0.17 73 144 10 AV1 +0.07*

8 AV3 +0.23 73 152 7 AV7 -0.02 8

AV6 -0.22 8

AV4 +0.24 8

AV1 -0.20 73 154 10 AV8 -0.20 7

AV6 -0.05 11 AV3 +0. 02 10 AV1 -0.25 74 15 6

AV7 -0.07 74 17 6

AV3 +0.16 9

AV4 +0.21 6

AV5 +0. 07 8

AV6 -0.16 9

AV7 +0.02 9

AV8 -0.12 9

AV1 +0.09 11 AV2 +0.21 74 19 7

AV2 +0.17 6

AV5 +0.07 7

AV6 +0.00 5

AV1 -0.10 74 21 9

AV4 +0.11 10 AV8 +0.05 74 23 5

AV1 -0.09 6

AV4 +0.23 7

AV6 +0.00 74 25 6

AV5 -0.14 5

AV6 -0.16 8

AV7 -0.14 74 29 6

AV4 +0.26 74 33 7

AV4 +0.26 5

AV7 -0.16 6

AV8 +0.07 74 35 7

AV3 +0.28 5

AV4 +0.00 7

AV5 +0.27 6

AV6 -0.14 74 55 13 AV4 +0.03 12 AV5 -0.12 9

AV6 +0.05 9

AV7 +0.02 74 57 12 AV6 +0.05 74 59 8

AV6 +0.07 74 61 12 AV6 +0.07 7

AV7 +0.05 74 63 12 AV2 +0.09 10 AV3 +0.11 10 AV4 +0.06 12 AV5 -0.09 9

AV7 +0.07 74 65 7

AV2 +0.05 10 AV3 +0.09 7

AV5 -0.03 15 AV6 +0.05 9

AV7 -0.05 74 67 8

AV5 -0.22 15 AV8 +0.12 74 69 8

AV4 +0.00 6

AV5 -0.18 9

AV6 +0.05 12 AV7 +0.04 74 71 10 AV1 +0.05 9

AV2 +0.09 8

AV3 +0.09 74 73 7

AV1 +0.05 19 AV2 +0.12 7

AV8 +0.02 L-2019-064 Enclosure Page 27 of 89 Page 11 of 32 ROW COL %TW LOCATION 74 75 6

AV2 +0.14 17 AV3 +0.09 10 AV4 +0.03 17 AV5 +0.02 15 AV7 +0.00 74 77 10 AV4 +0.03 19 AV5 +0.04 15 AV7 +0.00 74 79 10 AV4 +0.03 5

AV5 -0.20 12 AV6 +0.05 74 81 15 AV2 +0.12 18 AV5 +0.04 12 AV7 +0.00 5

AV8 +0.05 74 83 6

AV2 +0.05 16 AV3 +0.05 10 AV4 +0.00 12 AV5 +0.07 9

AV6 +0.02 6

AV7 +0.05 74 85 12 AV4 +0.00 10 AV5 -0.15 74 87 14 AV7 -0.02 18 AV6 +0.00 17 AV4 -0.05 8

AV2 -0. 02 74 89 12 AV2 -0.07 74 91 17 AV7 -0.07 17 AV6 -0.02 11 AV5 -0.21 6

AV4 +0.18 7

AV3 -0.07 6

AV2 -0.22 74 93 15 AV3 +0.07 11 AV4 +0.18 12 AV6 +0. 05 17 AV7 +0. 05 74 95 10 AV2 +0.09 16 AV3 +0.11 16 AV4 +0.06 17 AV5 +0.09 74 97 14 AV2 +0.07 12 AV7 +0.02 74 99 8

AV1 +0.07 15 AV2 +0.05 9

AV3 +0.07 15 AV5 +0.09 11 AV6 +0.07 9

AV7 +0.00 74 101 6 AV1 +0.02 15 AV2 +0.05 15 AV3 +0.02 74 103 11 AV2 +0.05 6

AV4 +0.24 7

AV5 +0.11 8

AV6 +0.09 17 AV7 -0.05 13 AV8 +0.05 74 105 7 AV1 +0.07 8

AV2 +0.07 19 AV4 +0.00 8

AV5 +0.07 12 AV7 +0.04 7

AV8 +0.07 74 107 12 AV2 +0.05 11 AV3 +0.09 13 AV4 +0.06 17 AV6 +0. 02 8

AV7 +0.02 74 109 12 AV2 +0.05 16 AV3 +0.07

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 16 AV4 +0.06 74 111 10 AV3 +0.07 18 AV4 +0.03 18 AV7 +0.04 74 113 13 AV2 +0.10 6

AV3 +0.09 9

AV7 +0.04 74 115 11 AV4 +0.28 11 AV8 +0. 05 74 117 10 AV2 +0.07 4

AV4 +0.16 74 119 11 AV2 +0.10 10 AV3 +0.13 74 123 9 AV5 +0.05 9

AV6 +0.05 74 125 12 AV7 +0.05 74 129 12 AV3 +0.11 74 137 6 AV2 +0.07 7

AV5 -0.21 7

AV3 +0.13 74 139 9 AV2 +0.09 6

AV5 -0.22 8

AV8 -0.13 74 141 8 6

6 74 143 9 AV3 +0.15 AV4 +0.06 AV7 +0.25 AV5 -0.25 74 145 17 AV1 +0.02 74 153 11 AV8 -0.20 6

AV5 -0.06 12 AV1 -0.21 75 16 5

AV2 +0.23 12 AV6 +0. 02 9

AV7 -0.11 7

AV8 +0.25 75 18 10 AV2 +0.28 16 AV4 +0.25 11 AV6 -0.02 75 20 7

AV1 +0.07 75 28 6

AV5 -0.20 75 30 8

AV4 +0.20 75 44 6

AV4 -0.21 75 75 75 75 75 75 75 75 75 10* AV5 +0.20 7

AV7 +0.05

\\1 AV8 +0.07 52 8

AV2 +0.12 8

AV5 -0.11 54 6

AV6 +0.07 56 12 AV5 +0.09 10 AV6 +0.07 60 6

AV4 +0.23 7

AV7 +0.02 62 12 AV4 +0.06 16 AV5 +0.07 12 AV6 +0. 05 64 9

AV5 +0.02 66 16 AV4 +0.00 19 AV6 +0. 07 13 AV7 +0.07 68 8

AV5 -0.15 70 11 AV5 +0.07 13 AV6 +0.11 18 AV7 +0.02 10 AV8 +0.05 75 72 8

AV2 +0.07 11 AV3 +0.09 75 74 6

AV1 +0.07 8

AV3 +0.11 15 AV4 +0.06 17 AV5 +0.09 17 AV6 +0.05 13 AV7 +0.05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 75 76 6

AV2 +0.05 17 AV3 +0.11 10 AV6 +0.05 75 78 18 AV3 +0.11 16 AV4 +0.06 13 AV5 +0.09 15 AV6 +0.09 9

AV7 +0.05 75 80 16 AV3 +0.09 18 AV4 +0.03 15 AV6 +0.02 75 82 11 AV5 +0.02 8

AV6 +0.02 12 AV7 +0.02 75 84 12 AV3 +0.09 14 AV4 +0.00 9

AV5 +0.07 75 86 19 AV7 -0.05 17 AV6 -0.05 15 AV5 -0.03 14 AV4 -0.07 7

AV2 +0.00 75 88 17 AV5 -0.03 10 AV4 +0.11 12 AV3 -0.07 75 90 7

AV7 -0.05 6

AV6 -0.05 15 AV5 +0.00 12 AV4 -0.09 6

AV3 -0.07 8

AV2 -0.20 75 92 9

AV7 -0.07 14 AV5 -0.06 17 AV4 -0.07 9

AV3 -0.07 7

AV2 -0.02 75 94 11 AV2 +0.12 19 AV3 +0.10 75 96 9

AV2 +0.02 16 AV3 +0.05 11 AV7 +0.05 75 98 15 AV2 +0.08 8

AV3 +0.07 18 AV5 +0.07 10 AV6 +0.05 75 75 75 75 75 75 75 100 12 AV2 +0.02 17 AV3 +0.07 16 AV4 +0.00 10 AV5 -0.09 8

AV8 +0.05 102 7 AV2 +0.05 17 AV7 +0.00 104 19 AV4 +0.18 106 12 AV3 +0.05 108 8 AV2 +0.05 19 AV5 +0.09 6

AV6 +0.23 10 AV7 +0.02 110 8 AV3 +0.09 10 AV4 +0.06 6

AV5 +0.05 9

AV6 +0.05 112 6 AV1 +0.09 8

AV2 +0.07 9

AV4 +0.09 11 AV6 +0.20 15 AV7 +0.05 12 AV8 +0.02 75 114 8 AV5 -0.21 75 116 5 AV2 +0.05 10 AV3 +0.07 13 AV4 +0.27 L-2019-064 Enclosure Page 28 of 89 Page 12 of 32 ROW COL %TW LOCATION 10 AV6 +0. 07 75 118 9 AV4 +0.27 8

AV5 +0.05 4

AV7 +0. 07 75 120 7 AV6 +0.02 12 AV7 +0.02 75 124 8 AV5 -0.09 75 134 7 AV3 +0.13 75 140 8 AV5 -0.23 8

AV6 +0.00 75 142 8 AV3 +0.05 8

AV5 -0.14 75 144 13 AV5 -0.15 8

AV6 +0. 02 12 AV7 +0. 05 8

AV8 -0.14 75 146 9 AV3 +0.05 6

AV4 +0.26 6

AV5 -0.18 75 148 8 AV5 -0.18 75 150 6 AV6 -0.09 11 AV5 -0.09 11 AV3 +0.00 6

AV1 -0.02 75 152 10 AV8 -0.21 11 AV7 -0.07 6

AV4 +0.21 11 AV2 -0.02 8

AV1 -0.25 75 154 13 AV8 -0.02 10 AV7 -0.05 8

AV6 -0.12 9

AV3 -0.02 6

AV2 -0.05 11 AV1 -0.23 76 17 7

AV1 -0.14 9

AV2 +0.22 8

AV6 -0.09 76 19 7

AV4 +0.20 7

AV6 +0.00 76 21 7

AV1 +0.05 10 AV4 +0.21 76 27 5

AV1 -0.02 76 29 76 31 76 33 76 35 76 41 76 45 76 55 76 59 76 61 76 63 10 AV2 +0.16 7

AV5 +0.05 7

AV4 +0.24 7

AV6 +0. 07 7

AV4 +0.22 8

AV4 +0.19 7

AV4 -0.16 5

AV5 -0.14 7

AV4 +0.30 5

AV4 -0.14 9

AV5 -0.14 16 AV2 +0. 07 13 AV3 +0.05 7

AV7 +0.09 4

AV5 -0.14 13 AV6 +0.07 12 AV7 +0.05 10 AV3 +0.12 16 AV4 +0.03 13 AV5 +0.05 16 AV6 +0.05 7

AV7 +0.05 76 65 16 AV2 +0.05 10 AV3 +0.05 18 AV6 +0.02 13 AV7 +0.12 76 67 6

AV3 +0.07 7

AV5 -0.19 12 AV6 +0.00

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 9

AV7 +0.00 76 69 8

AV3 +0.09 13 AV4 +0.03 6

AV5 -0.14 11 AV6 +0. 05 8

AV7 +0. 05 76 71 15 AV2 +0.07 15 AV5 +0. 07 15 AV6 +0.07 8

AV7 +0.09 76 73 10 AV3 +0.14 9

AV4 +0.14 11 AV6 +0.07 8

AV7 +0.02 76 75 18 AV2 +0.09 12 AV8 +0.05 76 77 9

AV2 +0.14 9

AV3 +0.09 11 AV4 +0.03 9

AV5 +0. 05 18 AV6 +0.07 14 AV7 +0.02 76 79 7

AV2 +0.09 15 AV4 +0.03 7

AV5 -0.05 11 AV6 +0.05 76 81 15 AV2 +0.12 76 83 6

AV2 +0.07 9

AV3 +0.09 8

AV5 +0. 07 9

AV6 +0.07 13 AV7 +0.05 76 85 9

AV3 +0.07 14 AV4 +0.03 11 AV5 +0.07 7

AV6 +0.05 76 87 16 AV7 -0.05 8

AV2 +0. 00 76 89 6

AV7 -0.05 18 AV6 -0.02 18 AV5 -0.03 15 AV4 -0.07 12 AV2 -0.07 76 91 8

AV7 -0.07 18 AV6 -0.05 16 AV5 -0.22 17 AV4 -0.07 14 AV3 -0.05 8

AV2 -0.05 76 93 9

AV2 +0.12 15 AV3 +0.02 9

AV4 +0.00 9

AV5 +0.09 76 95 8

AV2 +0.07 14 AV4 +0.23 7

AV5 -0.03 14 AV7 +0.07 76 97 7

AV2 +0.05 17 AV7 +0.05 76 99 8

AV1 +0.07 19 AV3 +0.12 12 AV4 +0.20 9

AV8 +0.05 76 101 7 AV4 +0.06 13 AV6 +0.09 9

AV2 +0.12 10 AV3 +0.07 76 103 7 AV1 +0.12 9

AV3 +0.19 18 AV6 +0.05 7

AV8 +0.05 76 105 17 AV2 +0.05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 13 AV6 +0.07 12 AV8 +0.05 76 107 6 AV1 +0.05 11 AV2 +0. 05 9

AV7 +0.07 76 109 7 AV2 +0.10 16 AV4 +0. 03 19 AV7 +0.05 76 111 9 AV8 +0.09 12 AV2 +0.12 18 AV3 +0.12 76 113 6 AV8 +0.05 17 AV6 +0.05 13 AV7 +0.05 76 115 12 AV3 +0.11 14 AV5 +0.12 19 AV6 +0.02 8

AV7 +0.00 76 117 7 AV2 +0.05 12 AV4 +0.06 10 AV5 +0.07 76 119 9 AV6 +0.02 76 121 9 AV5 -0.20 76 125 8 AV7 +0.05 76 137 7 AV2 +0.02 76 139 5 AV5 -0.17 76 143 13 AV5 -0.20 76 145 11 AV5 -0.14 6

AV6 +0.02 76 147 9 AV1 +0.16 18 AV2 +0.05 7

AV3 +0.09 7

AV4 +0.26 8

AV5 -0.14 76 151 11 AV2 +0.00 9

AV1 -0.20 76 153 11 AV5 -0.17 17 AV4 -0.02 9

AV3 +0.11 7

AV1 -0.27 15 AV8 -0.18 11 AV7 -0.05 77 16 7

AV1 -0.09 6

AV6 -0.16 77 18 7

AV1 +0.23 10 AV2 +0.30 10 AV5 -0.11 19 AV6 -0.02 8

AV7 +0.05 77 20 6

AV4 +0.22 77 22 9

AV4 +0.05 77 26 6

AV1 +0.26 7

AV2 +0.16 6

AV3 +0.19 8

AV4 +0.08 77 30 5

AV4 +0.14 77 36 9

AV4 +0.25 77 44 7

AV5 +0.20 77 46 5

AV4 +0.22 77 50 5

AV5 -0.11 77 54 7

AV4 +0.11 12 AV6 +0.05 9

AV7 +0.02 77 56 12 AV4 +0.28 5

AV5 +0.09 5

AV6 +0.05 77 60 7

AV3 +0.07 9

AV4 +0.17 16 AV5 +0.05 13 AV6 +0.05 9

AV7 +0.05 77 62 8

AV3 +0.12 L-2019-064 Enclosure Page 29 of89 Page 13 of 32 ROW COL %TW LOCATION 7

AV5 +0.05 77 64 18 AV3 +0.09 12 AV5 +0.05 11 AV6 +0. 05 10 AV7 -0.02 77 70 9

AV2 +0.05 15 AV3 +0.10 15 AV4 +0.00 11 AV5 +0.05 77 72 9

AV2 +0.05 10 AV3 +0.05 13 AV7 +0.05 77 74 8

AV3 +0.05 16 AV7 +0.07 77 76 17 AV7 +0.02 4

AV1 +0.37 11 AV2 +0.07 77 78 16 AV3 +0.07 10 AV6 +0. 09 77 80 9

AV2 +0.14 13 AV8 +0.07 77 82 6

AV3 +0.09 9

AV4 +0.22 12 AV5 +0.02 6

AV6 +0.02 13 AV7 +0.05 77 84 7

AV3 +0.02 14 AV4 +0.03 10 AV5 +0.05 77 86 15 AV4 -0.07 11 AV7 -0.05 12 AV6 -0.09 15 AV5 -0.08 77 88 14 AV6 -0.02 10 AV5 -0.17 14 AV4 -0.02 8

AV3 -0.05 10 AV2 -0.02 77 90 12 AV2 -0.02 15 AV7 -0.05 16 AV6 -0.05 77 92 17 AV2 +0.07 77 94 13 AV2 +0.10 14 AV3 +0.07 18 AV7 +0. 02 77 96 13 AV2 +0.10 12 AV3 +0.07 7

AV4 +0.03 16 AV5 +0.07 77 98 14 AV7 +0.05 9

AV8 +0.07 77 100 7 AV1 +0.07 9

AV2 +0.05 16 AV4 +0. 03 16 AV5 +0.07 8

AV8 +0.05 77 102 7 AV3 -0.12 13 AV7 +0.05 77 104 10 AV1 +0.05 18 AV2 +0.07 18 AV4 +0.03 77 106 15 AV2 +0.12 11 AV7 +0.04 77 108 10 AV2 +0.09 12 AV7 +0.05 77 110 8 AV5 +0.05 9

AV6 +0.02 6

AV7 +0.23 6

AV8 +0.19 77 112 7 AV2 +0.10 14 AV3 +0.12 11 AV8 +0.05

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 77 114 12 AV6 +0.05 16 AV7 +0.02 13 AV3 +0.07 77 116 6 AV1 +0.12 10 AV2 +0.10 77 118 10 AV3 +0.07 16 AV4 +0.19 15 AV5 +0.05 8

AV6 +0. 05 5

AV7 +0.00 77 120 10 AV6 +0.05 77 77 77 77 77 77 77 77 77 77 77 77 78 122 7 6

15 124 6 7

7 130 7 134 9 5

5 138 14 140 10 5

7 142 6 144 9 146 10 12 15 6

148 6 152 11 9

10 8

154 8 17 7

10 8

8 AV4 +0.08 AV5 +0.25 AV6 +0.05 AV4 +0.08 AV5 -0.11 AV6 +0.02 AV6 +0.26 AV3 +0.20 AV4 +0.06 AV5 -0.53 AV5 -0.14 AV4 +0.06 AV5 -0.56 AV8 +0.07 AV5 +0.24 AV5 -0.17 AV1 +0.09 AV2 +0.09 AV3 +0.14 AV5 -0.15 AV1 -0.09 AV8 +0.00 AV7 -0.07 AV6 -0.02 AV2 -0.05 AV1 -0.18 AV1 -0.16 AV2 +0.26 AV6 -0.12 AV8 +0.23 78 21 7

AV8 +0.00 78 23 9

AV4 +0.11 78 31 6

AV5 +0.05 78 35 7

AV5 +0.18 78 45 14 AV4 +0.29 78 47 6

AV4 +0.03 78 49 8

AV4 -0.12 7

AV5 +0.05 78 53 13 AV5 +0.02 13 AV6 +0. 07 78 55 8

AV6 +0.05 78 59 8

AV6 +0.02 11 AV7 +0.02 78 61 13 AV6 +0.05 78 63 7

AV1 +0.09 8

13 13 7

AV2 +0.14 AV3 +0.12 AV4 +0.08 AV5 +0.07 14 AV6 +0.11 78 67 10 AV3 +0.14 14 AV5 +0.05 19 AV6 +0.07 13 AV7 +0.05 78 69 8

AV1 +0.07 11 AV2 +0.07 11 AV7 +0.05 11 AV8 +0.02 78 71 12 AV1 +0.05 14 AV2 +0.05 11 AV3 +0.07 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 14 AV4 +0.03 9

AV5 +0.05 19 AV6 +0.05 15 AV7 +0.07 78 73 8

AV2 +0.02 17 AV4 +0.00 78 75 14 AV2 +0.05 18 AV4 +0.00 78 77 13 AV2 +0.09 16 AV3 +0.07 16 AV7 +0.07 78 79 78 81 78 83 78 85 78 87 78 91 78 93 78 95 8

AV3 +0.07 18 AV5 +0.07 14 AV7 +0.05 6

AV3 -0.09 6

AV5 -0.14 6

AVl -0.07 9

AV2 +0.09 18 AV3 +0.09 16 AV4 +0.00 17 AV7 +0.00 8

AV3 +0.09 16 AV4 +0.06 14 AV5 +0.07 11 AV6 +0. 07 16 AV5 -0.03 18 AV4 -0.05 16 AV3 -0.05 11 AV7 -0.02 19 AV6 -0.05 13 AV6 +0. 00 6

AV5 -0.22 10 AV4 -0.26 6

AV2 +0. 03 13 AV3 +0.04 13 AV4 +0.03 8

AV5 +0.09 7

AV1 +0.05 13 AV2 +0.05 17 AV5 +0.07 14 AV6 +0.05 16 AV7 +0.07 78 97 9

AV2 +0.02 19 AV7 +0.05 78 101 12 AV2 +0.05 12 AV3 +0.00 13 AV7 +0.04 78 107 8 AV2 +0.05 17 AV3 +0.05 11 AV5 +0.07 6

AV7 +0.05 6

AV8 +0.05 78 111 9 AV3 +0.12 5

AV7 +0.05 78 113 10 AV2 +0.05 17 AV5 +0.05 78 18 115 14 6

AV7 +0.02 AV3 +0.02 AV4 +0.00 10 AV5 -0.20 14 AV6 +0.00 6

AV7 +0.00 8

AV8 +0. 05 78 117 19 AV5 +0.28 18 AV6 +0.02 17 AV7 +0.07 78 121 11 AV5 +0.02 78 123 9 AV3 +0.02 8

AV5 +0.22 78 125 12 AV6 +0.09 12 AV7 +0.05 7

AV8 +0.02 L-2019-064 Enclosure Page 30 of 89 Page 14 of 32 ROW COL %TW LOCATION 78 133 7 AV3 +0.07 78 137 8 AV5 -0.17 7 8 13 9 7 7

78 143 7 AV3 +0.11 AV5 -0.17 AV3 +0.09 12 AV5 -0.16 78 145 10 AV2 +0.09 8

AV5 +0. 02 78 147 7 AV4 +0.03 78 149 11 AV7 +0.04 8

AV8 +0.19 78 78 79 79 79 79 79 79 79 79 151 8 AV3 -0.07 6

AV2 -0.02 8

AV1 -0.20 153 12 AV8 +0.16 18 AV7 -0.07 11 AV6 -0.07 6

AV5 -0.06 7

AV3 -0.02 6

AV2 +0.12 15 AV1 -0.25 18 20 22 24 30 34 36 46 7

6 8

8 8

6 8

7 9

7 5

7 7

6 6

10 6

6 9

9 AV1 +0.30 AV2 +0.28 AV3 +0.12 AV5 -0.11 AV6 -0.12 AV1 -0.46 AV2 +0.10 AV4 +0.22 AV7 +0.05 AV8 +0.05 AV2 +0. 02 AV4 +0.03 AV7 +0.05 AV4 +0.06 AV1 +0.14 AV2 +0.12 AV4 +0.11 AV5 +0.18 AV4 +0.27 AV1 +0.14 6

AV4 +0.08 79 50 6

AV4 +0.32 79 56 8

AV6 +0.05 79 62 16 AV4 +0.03 13 AV6 +0.05 79 64 12 AV5 +0.05 79 66 8

AV6 +0.07 79 68 14 AV3 +0.12 13 AV5 +0.09 18 AV6 +0.07 79 70 7

AV3 +0.09 17 AV5 +0.05 14 AV7 +0.02 79 72 15 AV3 +0.12 79 74 19 AV4 +0.06 11 16 12 AV2 +0.12 AV3 +0.10 AV8 +0.05 79 76 10 AV1 +0.14 8

AV2 +0.14 13 AV3 +0.14 11 AV8 +0. 07 79 78 10 AV2 +0.12 16 AV3 +0.14 19 AV5 +0.02 13 AV8 +0.05 79 80 18 AV3 +0.05 19 AV4 +0.03 79 82 13 AV3 +0.09 18 AV6 +0. 02 12 AV7 +0.05

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 79 84 6

AV3 +0.07 6

AV4 +0.03 7

AV5 +0.02 8

AV6 +0.05 79 86 12 AV7 -0.05 11 AV6 +0.02 17 AV5 -0.03 19 AV4 -0.05 9

AV2 -0.02 79 88 10 AV5 -0.03 8

AV4 -0.07 79 90 14 AV7 -0.02 12 AV5 -0.03 9

AV4 -0.07 18 AV3 -0.07 10 AV2 -0.02 79 92 14 AV2 +0.05 18 AV7 +0.02 79 94 13 AV2 +0.09 18 AV6 +0.05 11 AVS +0.00 79 96 18 AV2 +0.03 9

AV3 +0.02 79 79 79 79 79 79 79 79 79 18 AV5 +0.05 7

AV7 +0.04 7

AV8 +0.00 102 10 AV2 +0.09 9

AV7 +0.07 104 13 AV1 +0.02 18 AV4 +0.06 11 AV7 +0.04 13 AV8 +0.07 106 8 AV2 +0.02 15 AV7 +0.07 108 10 AVS +0.05 7

AV1 +0.05 8

AV2 +0.07 14 AV5 +0.02 110 17 AV2 +0.09 19 AV3 +0.09 5

AV4 +0.00 6

AV5 +0.28 13 AV6 +0.07 12 AV7 +0.07 112 8 AV2 +0.10 8

AV4 +0.06 10 AV5 +0.07 9

AV6 +0.07 114 10 AV3 +0.05 12 AV6 +0.09 10 AV7 +0.05 116 6 AV2 +0.10 6

AV3 +0.05 8

AV5 +0.26 6

AV1 +0.09 118 15 AV6 +0.05 12 AV7 +0.04 7

AV2 +0.07 12 AV5 +0.23 79 130 6 AV6 +0.09 79 132 6 AV2 +0.07 8

AV7 +0. 02 79 134 12 AV3 +0.13 7

AV4 +0.05 9

AV5 +0.14 7

AV6 +0.07 6

AV7 -0.07 79 138 7 AV2 +0.07 9

AV5 -0.23 79 144 7 79 146 7 7

AV5 -0.11 AV3 +0.26 AV8 -0.11 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 79 148 7 AV3 +0.07 79 150 7 AV3 -0.05 79 152 6 AV8 +0.17 80 19 7

AV1 +0.07 80 21 9

AV4 +0.11 80 25 5

AV6 -0.11 80 27 5

AV1 +0.05 5

AV2 +0.10 6

AV4 +0.19 80 29 8

AV4 +0.19 80 31 6

AV4 +0.22 80 33 6

AV4 +0.19 80 35 9

AV4 -0.12 6

AV5 +0.18 80 43 5

AV3 +0.09 80 45 6

AV4 +0.30 80 61 8

AV4 +0.05 8

AVS +0.05 14 AV6 +0.07 80 67 7

AV3 +0.09 14 AV4 +0. 03 13 AV7 +0.00 12 AV8 +0.12 80 69 5

AV1 -0.17 10 AV8 +0.07 80 71 18 AV8 +0.07 8

AV1 +0.05 11 AV2 +0.07 73 14 AV3 +0.05 19 AV7 +0.00 75 7

AV2 +0.14 8

AV3 +0.19 77 10 AV2 +0.05 5

AV7 +0.00 79 13 AV4 +0.05 13 AV6 +0.05 80 80 80 80 80 80 80 80 80 80 81 9

AV3 +0.09 9

AV4 +0.00 6

AV5 +0. 02 8

AV6 +0.02

  • 15 AV7 +0.02 6

AV8 +0.05 83 6

AV2 +0.02 14 AV3 +0.05 18 AV4 +0.05 85 10 AV3 +0.05 9

AV4 +0.03 9

AV5 +0.02 15 AV7 +0.02 87 17 AV7 -0.07 19 AV3 -0.07 9

AV2 -0.05 89 17 AV7 -0.05 91 6

AV7 -0.02 13 AV5 +0.00 13 AV4 -0.26 7

AV2 +0.00 80 93 11 AV3 +0;02 19 AV6 +0.07 11 AV7 +0.05 80 95 9

AV2 +0.07 18 AV6 +0.02 12 AV7 +0.05 80 99 17 AV2 +0.05 12 AV3 +0.05 12 AV4 +0.00 80 101 8 AV1 +0.07 15 AV7 +0.05 9

AV8 +0.02 80 105 17 AV2 +0.07 10 AV3 +0.12 9

AV4 +0.08 L-2019-064 Enclosure Page 31 of 89 Page 15 of 32 ROW COL %TW LOCATION 7

AV6 -0.07 13 AV7 +0.09 80 107 9 AV2 +0.07 17 AV3 +0.12 13 AV4 +0.05 16 AV5 +0.05 15 AV7 +0.05 80 111 19 AV6 +0.02 8

AV7 +0.02 8

AV2 +0.12 14 AV3 +0.16 80 113 13 AV2 +0.10 12 AV3 +0.11 18 AV4 +0.05 15 AV5 +0.07 11 AV6 +0.00 80 115 7 AV2 +0.09 11 AV3 +0. OS 15 AV5 -0.19 5

AVS +0.07 80 117 8 AV3 +0.07 11 AV4 +0.11 18 AV6 +0.02 8

AVS +0.02 80 121 9 AVS +0.09 80 125 7 AV2 +0.21 8

80 133 6 6

so 135 10 7

80 137 10 12 80 145 6 7

7 80 147 5 80 149 6 8

81 18 6

6 81 22 8

81 26 7

81 32 6

81 34 6

6 6

81 36 11 7

81 38 8

81 40 7

81 44 6

81 46 6

10 81 50 8

81 52 9

81 54 7

AV3 +0.11 AV2 +0. 05 AV5 +0. 02 AV2 +0.14 AV4 +0.11 AV3 +0.16 AV5 -0.20 AV1 +0.22 AV5 +0.07 AV6 +0.00 AV8 +0.28 AV4 +0.11 AV8 +0.21 AV1 -0.17 AVS +0.25 AV4 +0. 03 AV5 +0. 05 AV7 +0.05 AV3 +0.12 AV4 +0.08 AV5 +0.25 AV4 +0.29 AV5 -0.18 AV4 +0.16 AV4 +0.29 AV2 +0.20 AV2 +0.02 AV4 +0.13 AV4 +0.35 AV4 +0.21 AV6 +0.02 81 56 6

AV4 +0.32 81 64 10 AV3 +0.09 8

AV5 +0.05 13 AV6 +0.05 81 66 10 AV2 +0.07 12 AV3 +0.07 11 AV4 +0.03 13 AV7 +0.02 81 68 7

AV3 +0.07 7

AV4 +0.05 81 70 9

AV1 +0.09 13 AV4 +0.08 18 AV7 +0.04 7

AVS +0.05 81 72 7

AV1 +0.07

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 81 74 16 AV2 +0.07 10 AV3 +0.07 14 AV5 +0.09 14 AV7 +0.05 81 76 6

AV1 +0.07 8

AV2 +0.07 17 AV3 +0.07 6

AV6 +0.07 15 AV7 +0.02 81 78 19 AV3 +0.12 19 AV7 +0.02 81 80 6

AV3 +0.07 9

AV4 +0.00 81 81 81 81 81 81 81 81 81 81 81 81 81 81 82 84 86 88 90 92 14 AV5 +0.05 18 AV6 +0.02 17 AV7 +0.02 12 AV2 +0.07 8

AV1 +0.12 9

AV3 +0.09 7

AV4 +0. 03 9

AV5 +0. 07 16 AV6 +0.07 15 AV7 -0.02 7

AV5 -0.22 7

AV3 -0.05 4

AV2 +0.32 17 AV7 -0.05 16 AV6 -0.02 19 AV5 -0.03 6

AV2 +0.44 9

AV7 +0.00 13 AV6 +0.00 19 AV5 +0.02 6

AV4 -0. 05 9

AV2 -0.05 13 AV4 +0.16 11 AV7 +0. 05 16 AV2 +0. 05 94 8

AV1 +0.07 15 AV2 +0.07 16 AV6 +0.07 17 AV7 +0.05 96 7

AV2 +0.05 14 AV3 +0.09 11 AV7 +0.07 100 6 AV1 +0.05 13 AV2 +0.07 19 AV7 +0.02 102 6 AV1 +0.07 17 AV3 +0.05 14 AV5 +0.07 18 AV7 +0.05 106 6 AV1 +0.07 13 AV2 +0.07 15 AV3 +0.09 17 AV5 +0.05 9

AV6 +0.16 6

AV7 +0.05 108 14 AV2 +0.05 15 AV4 +0.03 16 AV6 +0. 05 8

AV7 +0.07 110 9 AV3 +0.05 18 AV4 +0.03 13 AV6 +0. 07 12 AV7 +0. 05 112 8 AV2 +0.02 12 AV3 +0.09 5

AV4 -0.12 8

AV6 +0.21 81 114 6 AV1 +0.02 11 AV2 +0.09 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 14 AV3 +0.02 11 AV6 +0.07 81 116 9 AV2 +0.07 9

AV4 +0.05 14 AV5 +0.07 18 AV6 +0.02 81 118 8 AV5 +0.11 81 122 7 AV3 +0.02 81 128 5 AV3 -0.12 5

AV5 -0.19 81 130 6 AVS -0.16 81 132 6 AV3 +0.05 8

AVS +0.02 14 AV7 +0.04 81 134 8 AV2 +0.09 81 81 81 81 81 81 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 9

AV3 +0.11 8

AV4 +0. 03 138 6 AV3 +0.12 7

AVS -0.14 140 7 AV4 +0.05 5

AV8 -0.11 146 8 AV1 -0.09 7

AV4 +0.08 148 6 AV1 -0.14 7

AV3 +0.17 7

AVS +0.05 12 AV7 +0.05 9

AV8 +0.23 150 8 AV1 -0.18 152 7 AV1 -0.29 19 6

AV1 -0.10 25 6

AV3 +0.17 27 6

AV4 +0.08 6

AVS +0.05 35 7

AV3 +0.17 6

AV4 -0.10 10 AVS +0.19 10 AV6 +0.05 7

AV7 -0.02 41 45 53 55 59 65 67 77 79 81 83 85 87 89 91 7

AV3 +0.17 9

AV4 +0.28 8

AV6 +0. 02 7

AV4 -0.16 5

AV4 +0.29 10 AV6 +0.02 12 AV7 +0.00 9

AV6 +0. 05 16 AV1 +0.07 9

AV2 +0.12 16 AV3 +0.19 8

AV4 +0.13 18 AV8 +0.07 19 AV2 +0.07 18 AV7 +0.02 6

AV8 +0.05 9

AV2 +0.14 17 AV3 +0.12 17 AV4 +0. 05 19 AV6 +0.05 10 AV2 +0. 07 11 AV3 +0.09 5

AV2 +0.09 10 AV3 +0.07 8

AV6 -0.02 11 AV5 +0.00 9

AV3 -0.02 17 AV6 -0.02 13 AV7 -0.07 5

AV2 -0.07 82 93 6

AV1 +0.12 10 AV2 +0.10 13 AV3 +0.12 L-2019-064 Enclosure Page 32 of 89 Page 16 of 32 ROW COL %TW LOCATION 82 95 9

AV1 +0.05 19 AV8 +0.02 82 97 7

AV1 +0.09 18 AV2 +0.07 9

AV3 +0.11 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 83 83 83 83 83 83 83 83 83 83 83 83 99 14 18 107 9 13 AV3 +0.11 AV8 +0.00 AV2 +0.05 AV3 +0.07 10 AVS +0. 07 18 109 9 12 AV8 +0.07 AV1 +0.05 AV2 +0.07 15 AV3 +0.07 18 AVS +0.09 13 11 1117 12 8

17 7

1135 8

6 8

115 9 8

15 117 11 18 15 123 5 6

127 8 8

5 6

131 10 133 10 11 15 6

135 8 137 8 5

139 8 8

141 7 20 7

6 26 7

7 36 8

38 7

40 5

46 6

50 10 60 12 12 62 7

7 64 12 19 10 66 7

9 68 8

AV7 +0. 05 AV8 +0.07 AV2 +0.12 AV4 +0.11 AVS +0.12 AV6 +0.07 AV7 +0.07 AVS +0.16 AV8 +0.07 AV2 +0.10 AV3 +0.07 AV3 +0.14 AV4 +0.13 AVS -0.16 AV3 +0.16 AV4 +0. 05 AV7 +0.05 AVS +0.21 AV7 +0.25 AV2 +0.05 AV3 +0.09 AV4 +0.23 AVS +0.21 AV2 +0.09 AV3 +0.14 AV4 +0.11 AVS +0.05 AV6 +0.02 AV2 +0.12 AV3 +0.09 AVS -0.17 AV4 +0.06 AV5 -0.11 AV2 +0.05 AV1 -0.13 AV2 +0.12 AV3 +0.17 AVS +0.02 AV4 +0.22 AVS +0.05 AVS +0.02 AV4 +0.24 AV4 +0.21 AV6 +0.07 AV7 +0.05 AV2 +0.14 AVS +0.07 AV4 +0.08 AV7 +0.00 AV8 +0.12 AV3 +0.09 AV4 +0.05 AV3 +0.07 17 AV4 +0.05 83 70 12 AV1 +0.09 6

AV2 +0.16 9

AV3 +0.14

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 8

AV5 +0.07 17 AV6 +0.09 6

AV7 +0.29 83 72 11 AV2 +0.07 18 AV3 +0.09 19 AV4 +0.03 17 AV8 +0.05 83 74 7

AV2 +0.07 83 76 7

AV1 +0.05 15 AV2 +0.09 83 78 5

AV2 +0.07 18 AV3 +0.07 83 80 10 AV3 +0.09 12 AV8 +0.05 83 82 83 84 83 86 83 88 83 92 83 94 83 96 13 AV3 +0.09 10 AV4 +0.03 9

AV6 +0. 05 14 AV7 +0.05 6

AV2 +0.07 15 AV4 +0.05 17 AV6 +0.09 16 AV7 +0.05 7

AV4 -0.02 12 AV3 -0.02 11 AV3 -0.05 6

AV2 -0.02 14 AV2 +0.15 11 AV8 +0.02 6

AVl +0.05 14 AV2 +0.10 10 AV8 +0.05 12 AV2 +0.10 18 AV7 +0.05 83 98 14 AV2 +0.05 12 AV7 +0.05 83 100 9 AVl +0.05 16 AV2 +0.07 12 AV3 +0.07 83 102 8 AVl +0.09 83 104 10 AV7 +0.04 10 AV8 +0.05 7

AVl +0.00 83 106 11 AV2 +0.12 11 AV3 +0.14 83 108 8 AV7 +0.07 83 110 10 AV3 +0.14 19 AV4 +0.08 17 AV6 +0.05 12 AV7 +0.05 83 112 12 AV2 +0.10 17 AV3 +0.07 17 AV5 +0.05 11 AV6 +0.09 83 114 7 AVl +0.09 12 AV2 +0.07 10 AV4 +0.08 83 116 11 AV2 +0.12 11 AV7 +0. 07 83 122 7 AV6 +0.07 83 124 8 AV4 +0.08 83 6

132 9 10 19 7

83 134 9 7

8 83 136 8 83 138 8 6

7 AV5 +0. 02 AV2 +0.07 AV5 +0.02 AV7 +0.07 AV8 +0.07 AV4 +0.11 AV6 +0.00 AV3 +0.18 AV5 +0.05 AV2 +0.07 AV3 +0.14 AV4 +0.06 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 8

AV6 +0.05 83 140 7 9

9 AV2 +0.10 AV3 +0.14 AV4 +0.08 7

AV5 +0.05 14 AV6 +0.05 17 AV7 +0. 02 11 AV8 +0.05 83 142 11 AV7 +0.05 83 146 7 AV3 +0.17 6

AV8 -0.11 83 148 7 AV8 +0.21 83 150 10 AVl -0.23 84 35 9

AV5 +0.05 84 84 84 84 84 84 84 84 45 47 51 61 63 65 67 69 8

AV3 +0.19 7

AV4 +0.28 11 AV4 +0.26 7

AV4 +0.16 7

AV4 +0.10 10 AV6 +0. 07 9

AV8 +0. 05 17 AV7 +0.07 14 AV2 +0.09 8

AV3 +0.14 12 AV5 +0. 02 12 AV6 +0.07 6

AV7 +0.07 9

AV5 +0.07 15 AV3 +0.12 7

AV7 +0.05 9

AV8 +0.11 7

AVl +0.09 9

AV2 +0.09 13 AV3 +0.10 18 AV8 +0.07 84 71 7

AV2 +0.12 84 73 13 AV2 +0.19 10 AV8 +0.05 84 75 6

AVl +0.07 19 AV2 +0.07 14 AV6 +0.07 84 79 9

AV2 +0.05 18 AV4 +0.00 13 AV7 +0.02 84 81 6

AV3 +0.05 18 AV4 +0.05 9

AV7 +0.05 84 83 7

AVl +0.12 14 AV2 +0.14 8

AV4 +0.05 17 AV7 +0.07 84 87 19 AV7 -0.05 13 AV2 -0.05 84 89 17 AV7 -0.07 15 AV2 -0.09 5

AV1 -0.05 84 91 5

AV2 -0.07 84 95 7

AVl +0.07 18 AV3 +0.05 10 AV7 +0.07 84 101 11 AV2 +0.07 84 84 16 105 10 14 18 107 9 15 AV3 +0.09 AV1 +0.07 AV2 +0.05 AV7 +0.07 AV2 +0.05 AV5 +0.07 84 109 15 AVl +0.05 16 AV4 +0.03 16 AV5 +0.07 13 AV7 +0.05 84 111 15 AV2 +0.09 L-2019-064 Enclosure Page 33 of 89 Page 17 of 32 ROW COL %TW LOCATION 16 AV3 +0.12 6

AV4 +0.06 14 AV5 +0.07 15 AV6 +0.05 84 113 8 AVl +0.07 12 AV2 +0.07 16 AV6 +0. 02 84 115 18 AV3 +0.10 9

AV7 +0.00 84 117 7 AVl +0.05 14 AV2 +0.07 16 AV3 +0.12 17 AV7 +0.07 6

AV8 +0.02 84 84 84 84 84 84 84 84 84 84 84 85 85 85 85 85 121 6 7

123 6 125 9 131 11 133 7 137 10 139 7 141 6 6

143 6 145 6 7

147 6 36 8

40 7

48 7

50 6

56 8

AV4 +0. 06 AV6 +0. 02 AV5 +0.14 AV2 +0.09 AV2 +0.05 AV3 +0.12 AV5 -0.16 AV8 -0.14 AVl +0. 05 AV2 +0.09 AV3 +0.17 AV3 +0.12 AV7 +0.02 AV7 +0.00 AV4 +0.23 AV4 +0.21 AV4 +0.10 AV4 +0.34 AV4 +0.29 6

AV5 +0.07 9

AV7 +0.02 85 60 6

AV4 +0.34 8

AV6 +0.05 9

AV7 +0.05 85 66 7

AV3 +0.16 85 68 18 AV3 +0.12 13 AV4 +0.16 18 AV5 +0.05 85 70 5

AV2 +0.09 85 78 11 AV2 +0.12 18 AV3 +0.14 5

AV8 +0.19 85 80 12 AV3 +0.07 18 AV4 +0.03 19 AV5 +0.05 18 AV7 +0.02 85 82 18 AV3 +0.14 85 86 5

AV8 +0.46 10 AV2 -0.11 85 88 13 AV7 -0.02 5

AV6 -0.02 6

AV3 +0.00 6

AV2 +0.00 85 90 18 AV6 +0.02 8

AV4 -0.02 9

AV2 +0.02 85 92 7

19 17 85 94 7

11 18 19 AV2 +0.07 AV3 +0.07 AV8 +0.05 AV1 +0. 07 AV2 +0.05 AV3 +0.05 AV7 +0.05 10 AV8 +0.05 85 100 17 AV7 +0.05 85 106 6 AVl +0.07 14 AV5 +0.02 15 AV6 +0. 02

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 11 AV7 +0. 07 85 108 6 AV1 +0.21 18 AV2 +0.05 17 AV5 +0.07 8

AV7 +0.05 85 112 6 AV1 +0.21 13 AV2 +0.10 9

AV3 +0.09 12 AV4 +0.08 6

AV5 +0.07 85 114 10 AV3 +0.00 7

AV4 +0.03 9

AV5 +0.02 11 AV6 +0.02 85 116 7 AV1 +0.07 10 AV3 +0.05 10 AV4 +0.11 11 AV5 +0.23 11 AV6 +0.05 85 118 6 AV4 +0.25 17 AV5 +0.05 9

AV6 +0.05 10 AV7 +0.05 7

AV8 +0. 05 85 122 6 AV3 +0.26 85 124 7 AV4 +0.11 85 128 6 AVl +0.05 85 130 9 AV6 +0.00 85 132 6 AV3 +0.07 85 134 7 AV4 +0.08 85 85 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 9

AV5 +0.09 6

AV6 +0.02 6

AV8 -0.11 138 8 6

142 6 23 5

41 5

43 5

45 6

6 51 5

53 6

55 6

59 6

8 63 9

8 7

65 8

69 75 77 79 83 87 7

9 8

11 11 15 15 9

16 12 8

11 11 11 13 16 8

18 6

AV2 +0.09 AV3 +0.14 AV8 +0. 23 AVl -0.14 AV3 +0.09 AV4 +0.21 AV4 +0.23 AVS -0.16 AV4 +0.08 AV2 +0. 05 AVl +0. 09 AV3 +0.09 AV4 +0.08 AVl +0. 05 AV6 +0.05 AV7 +0.07 AVl +0.07 AV2 +0. 07 AV4 +0.11 AV5 +0.09 AV6 +0.05 AV3 +0.12 AV6 +0.09 AV7 +0.04 AVl +0.12 AV3 +0.07 AV2 +0.09 AV4 +0.08 AV5 +0.05 AV6 +0.07 AV2 +0.02 AV3 +0.03 AV7 +0.05 AV7 -0.02 AV6 +0.00 AV2 -0.02 86 89 18 AV7 -0.05 14 AV2 +0.02 86 91 5

AV8 -0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 11 AV7 -0.05 12 AV3 -0.02 86 97 11 AV2 +0.07 16 AV4 +0.05 86 99 8

AV7 +0.11 7

AV8 +0.07 9

AV2 +0.07 12 AV3 +0.07 9

AV4 +0.05 19 AV5 +0. 05 86 101 13 AV2 +0.08 86 103 9 AV5 +0.02 86 105 15 AV4 +0.08 18 AV5 +0.07 6

AV6 +0.07 86 107 11 AV4 +0.08 9

AV5 +0.07 8

AV6 +0.07 9

AV7 +0.07 6

AVl +0.07 12 AV2 +0.07 86 109 18 AV3 +0.02 16 AV4 +0.03 86 111 9 AV3 +0.05 6

AV4 +0.08 7

AV6 +0. 05 86 113 6 AVl +0.07 17 AV3 +0.05 11 AV4 +0.03 6

AV8 +0.05 86 115 5 AV2 +0.05 9

AV3 +0.07 5

AV4 -0.14 10 AV5 +0.02 86 86 86 86 86 86 86 87 87 87 87 87 87 87 87 87 87 87 87 117 8 AV3 +0.05 14 AV4 -0.02 9

AV5 +0.05 5

AV6 +0.07 9

AV7 +0.05 121 7 AV4 +0.05 125 7 AV2 +0.05 129 5 AVS -0.11 135 16 AV2 +0.14 7

AV3 +0.17 9

AV5 +0.02 139 6 AV4 +0.05 147 7 AV3 +0.20 9

AV7 +0.00 26 6

AVl +0.30 36 7

AV4 +0.28 42 6

AV4 +0.10 44 8

AV3 +0.16 46 52 54 60 64 66 68 70 10 8

9 7

5 6

6 10 10 9

9 8

12 8

9 9

7 AV4 +0.13 AV4 +0.11 AV7 +0.02 AV3 +0.07 AV4 +0.26 AV5 +0.07 AV4 +0.29 AV3 +0.05 AV4 +0. 03 AV5 +0.02 AV4 +0.05 AV6 +0.07 AV5 +0. 05 AV6 +0.12 AV8 +0. 02 AV3 +0.10 AV8 +0.05 87 72 7

AVl +0.07 8

AV2 +0.12 12 AV3 +0.19 L-2019-064 Enclosure Page 34 of 89 Page 18 of 32 ROW COL %TW LOCATION 11 AV8 +0.09 87 74 8

AV2 +0.14 18 AV3 +0.09 18 AV4 +0. 05 15 AV6 +0.07 16 AV7 +0.02 87 76 8

AVl +0.14 8

AV2 +0.12 9

AV3 +0.09 17 AVS +0.05 8

AV6 +0.05 16 AV7 +0.05 7

AV8 +0.05 87 78 7

AV2 +0.00 13 AV3 +0.10 13 AV4 +0.08 10 AVS +0.05 9

AV7 +0.05 87 80 13 AV2 +0.12 13 AV7 +0.05 87 82 6

AV2 +0.07 87 84 11 AV2 +0.12 19 AV3 +0.12 87 86 15 AV7 -0.02 19 AV2 -0.02 87 88 7

AV7 -0.07 8

AV6 -0.05 7

AV3 -0.05 7

AV2 +0.00 87 90 10 AV8 +0.00 7

AV2 -0.02 87 92 16 AV2 +0.05 87 96 6

AVl +0.05 87 87 87 87 87 87 87 87 87 87 87 87 87 8

8 100 7 10 106 7 13

,6 108 7 18 13 6

110 8 12 9

14 112 12 6

7 8

114 6 7

5 8

19 116 6 8

7 5

118 7 120 6 5

126 6 130 7 132 8 148 7 7

8 88 25 7

88 33 4

AV6 +0.07 AV7 +0.07 AVl +0.05 AV7 +0.05 AVl +0.05 AVS +0.07 AV7 +0.09 AV1 +0. 07 AV2 +0.07 AVS +0.07 AV6 +0.05 AVl +0.02 AV2 +0.05 AV4 +0.08 AV5 +0.05 AV2 +0.12 AV3 +0.12 AV6 +0.07 AV7 +0.07 AVl +0.07 AV2 +0.07 AV4 +0.03 AVS +0. 07 AV8 +0.02 AV2 +0.05 AVS -0.16 AV6 +0.05 AV7 +0.34 AV2 +0.07 AV3 -0.02 AV4 +0.18 AV3 +0.10 AVS +0. 02 AVS +0. 00 AVl -0.11 AV6 +0.05 AV8 +0.23 AVl +0.09 AV5 -0.15

Frarnatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVE Wear 1-19%

ROW COL %TW LOCATION 88 35 6

AV4 +0.29 88 88 88 88 88 88 88 88 88 88 88 88 37 39 45 55 61 63 65 67 69 71 73 75 7

AV6 +0.05 5

AV5 +0. 02 7

AV5 -0.13 6

AV4 +0.26 13 AV6 +0.09 12 AV7 +0.05 7

AV2 +0.02 7

AV6 +0.05 12 AV7 +0.05 11 AV3 +0.09 5

AV2 -0.02 8

AV3 +0.12 9

AV5 +0. 05 5

AV6 +0.02 10 AV7 +0.11 11 AV3 +0. 07 5

AV4 +0.08 13 AV5 +0. 05 7

AVl +0.05 16 AV2 +0.09 17 AV3 +0.12 12 AV1 +0.07 16 AV5 +0.07 7

AV7 +0.00 9

AV3 +0.14 10 AV4 +0.08 16 AV5 +0.05 88 79 5

AV2 +0.02 6

AV3 +0.09 7

AV4 +0.08 15 AV6 +0. 05 13 AV7 +0. 05 6

AV8 +0.05 88 81 7

AV2 +0.12 88 83 15 AV2 +0.09 11 AV4 +0. 08 15 AV5 +0.09 9

AV6 +0.07 9

AV8 +0.07 88 85 8

AV3 +0.09 16 AV4 +0.00 18 AV5 +0.09 19 AV6 +0.10 88 87 11 AV7 -0.02 12 AV5 +0.00 9

AV2 -0.02 88 89 17 AV7 -0.02 8

AV3 -0.05 88 91 5

AV8 -0.05 19 AV7 -0.07 19 AV5 -0.05 19 AV3 -0.05 14 AV2 -0.02 6

AV1 -0.05 88 93 10 AV3 +0.09 16 AV4 +0.08 10 AV7 +0.05 88 95 14 AV2 +0.10 8

AV6 +0.05 11 AV7 +0.02 88 97 19 AV5 +0.07 19 AV6 +0. 07 9

AV2 +0.10 10 AV3 +0.09 88 99 14 AV2 +0.12 12 AV5 +0.10 11 AV7 +0.05 88 101 10 AV1 +0.07 16 AV2 +0.09 19 AV7 +0.05 88 107 9 AV2 +0.10 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 15 AV4 +0.11 88 88 88 88 88 10 10 109 13 6

12 111 5 8

113 5 10 8

1159 117 8 12 9

6 6

88 121 8 88 123 7 88 88 129 7 137 7 8

8 7

88 147 6 9

8 89 26 6

7 9

89 40 5

89 46 7

5 89 48 6

89 50 6

7 89 54 9

89 62 7

89 66 7

7 AV5 +0.07 AV6 +0. 07 AV5 +0. 05 AV7 +0.05 AV2 +0.12 AV4 -0.09 AV5 +0. 02 AV4 +0.26 AV1 +0.07 AV3 +0.14 AV5 -0.20 AV2 +0.12 AV3 +0.12 AV4 +0.05 AV5 -0.19 AV6 -0.47 AV3 +0.07 AV4 +0.16 AV2 +0.14 AVl +0. 05 AV2 +0. 07 AV3 +0.13 AV7 +0.05 AV3 +0.10 AV7 +0.00 AV8 +0.23 AV2 +0.12 AV6 +0.05 AV7 +0.02 AV5 +0.05 AV2 +0.05 AV3 +0.05 AV4 +0.03 AV4 +0. 31 AV5 -0.10 AV4 +0.13 AV3 +0.14 AV4 +0.05 AV7 +0.02 89 68 16 AV4 +0.13 16 AV5 +0.09 14 AV6 +0.09 18 AV7 +0.07 89 70 9

AV3 +0.12 7

AV4 +0.13 6

AV5 +0.14 5

AV6 +0.09 89 72 15 AV2 +0.08 19 AV3 +0. 07 18 AV7 +0.02 89 74 7

AV2 +0.05 19 AV4 +0.08 89 78 4

AV2 -0.12 10 AV3 +0.05 6

AV6 +0.26 9

AV7 +0.05 89 80 9

AV3 +0.12 9

AV4 +0.08 13 AV6 +0.02 18 AV7 +0.02 6

AV2 +0.09 89 82 14 AV2 +0.05 16 AV3 +0.09 16 AV8 +0.02 89 84 11 AV3 +0.05 6

AV4 +0.03 19 AV5 +0.07 89 90 19 AV2 +0.12 12 AV7 +0.07 89 92 15 AV2 +0.09 18 AV4 +0.03 L-2019-064 Enclosure Page 35 of 89 Page 19 of 32 ROW COL %TW LOCATION 10 AV5 +0.07 11 AV7 +0.05 89 89 89 89 96 9

AV2 +0.12 11 AV4 +0. 05 6

AV5 +0.07 17 AV6 +0.09 102 14 AVl +0.09 11 AV5 +0.23 16 AV6 +0.09 106 7 AV3 +0.12 14 AV6 +0.07 10 AV7 +0.09 108 10 AVl +0.09 13 AV2 +0.12 10 AV3 +0.11 9

AV5 +0.09 12 AV6 +0.02 9

AV8 +0.05 89 110 10 AV6 +0.00 89 89 89 16 8

112 13 10 114 10 7

116 7 8

6 89 118 7 8

89 120 8 89 148 6 90 37 6

9 90 41 9

90 43 7

7 90 51 7

90 53 8

8 AV7 +0.05 AV8 +0.07 AV2 +0.15 AV7 +0.04 AV4 +0.11 AV5 +0.02 AV2 +0.12 AV4 +0.13 AV5 -0.11 AV5 +0.09 AV6 +0.02 AV5 +0.02 AVl -0.14 AV2 +0.12 AV6 +0.05 AV4 +0.15 AV2 +0.05 AV5 +0. 07 AV5 +0.05 AV3 +0.09 AV4 +0.10 90 55 8

AV4 +0.15 90 57 12 AV5 +0.05 90 61 7

AV4 +0.18 90 63 10 AV3 +0.16 7

AV6 +0. 07 90 65 8

AVl +0.14 15 AV2 +0.14 15 AV3 +0.14 90 67 12 AV6 -0.02 90 69 7

AV2 +0.07 12 AV3 +0.12 90 73 9

AV2 +0.05 14 AV4 +0.08 12 AV8 +0.07 90 75 14 AV2 +0.07 16 AV3 +0.12 17 AV4 +0.08 17 AV8 +0.07 9

AVl +0.07 90 79 10 AV3 +0.12 12 AV4 +0.05 15 AV6 +0.05 90 83 9

AV2 +0.16 17 AV4 +0.08 19 AV6 +0.07 90 85 7

AV2 +0.07 13 AV3 +0.12 8

AV8 +0.07 90 87 9

AV2 +0.12 90 91 11 AV2 +0.07 18 AV7 +0.00 90 99 11 AVl +0.07

Frarnatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 11 AV6 +0. 05 15 AV7 +0.02 90 103 19 AV2 +0.12 90 105 14 AV3 +0.05 17 AV8 +0.07 90 107 6 AV2 +0.27 8

AV3 +0.09 6

AV4 +0.10 12 AV5 +0.07 10 AV6 +0.07 16 AV7 +0.07 90 90 90 90 90 90 90 109 9 AV7 +0.07 7

AV3 +0.14 5

AV6 +0.07 111 6 AV4 +0.10 5

AV6 -0.52 7

AV7 +0.09 113 6 AV1 +0.09 8

AV3 +0.07 11 AV6 +0.00 115 6 AV2 +0.02 7

AV5 +0.26 6

AV6 +0.07 117 5 AV4 -0.12 7

AV6 +0.05 121 8 AV3 +0.12 125 7 AV3 +0.08 90 129 7 AV2 +0.05 90 131 7 AV3 +0.10 90 139 7 AV2 +0.12 6

AV8 +0.12 91 56 7

AV5 +0.07 7

AV7 +0.02 91 58 6

AV2 +0.10 91 62 10 AV6 +0.05 91 64 16 AV4 +0.13 13 AV6 +0. 07 13 AV7 +0.00 91 66 7

AV4 +0.18 10 AV6 +0.09 91 68 11 AV2 +0.05 7

AV4 +0.13 19 AV5 +0.07 19 AV6 +0. 05 91 70 7

AV1 +0.07 8

AV3 +0.12 19 AV6 -0.02 8

AV7 -0.14 91 72 15 AV2 +0.12 15 AV4 +0.08 91 76 15 AV3 -0.02 12 AV2 -0.02 91 80 6

AV8 -0.05 16 AV3 -0.07 91 82 18 AV3 -0.09 8

AV2 -0.05 91 84 7

AV8 -0.02 15 AV3 -0.07 10 AV2 -0.09 91 88 16 AV8 -0.02 11 AV3 -0.05 7

AV2 -0.02 6

AV1 -0.02 91 90 17 AV3 -0.02 6

AV2 +0.00 91 92 16 AV5 +0.00 18 AV2 -0.02 91 94 7

AV8 -0.02 6

AV1 -0.05 91 96 19 AV2 -0.05 10 AV1 -0.02 91 98 18 AV2 +0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 91 100 9 AVl +0.10 17 AV2 +0.12 16 AV4 +0.16 10 AV5 +0.09 91 106 17 AV2 +0.10 13 AV5 +0.07 18 AV6 +0.05 6

AV7 +0. 07 91 108 15 AV7 +0.05 5

AVl +0.07 17 AV2 +0.10 110 12 AV2 +0.12 19 AV3 +0.07 18 AV6 +0.05 112 13 AV3 +0.14 91 91 91 91 91 92 92 6

AV5 +0.07 6

AV6 +0.07 114 5 AV2 -0.02 7

AV5 +0.02 8

AV7 +0.05 116 14 AV3 +0.05 18 AV5 +0.07 7

AV7 +0.07 118 6 AV6 +0.02 8

AV2 +0.05 45 7

AV5 -0.13 47 7

AV2 +0.09 7

AV4 +0.13 92 49 8

AV4 +0.03 92 51 8

AV2 +0.07 10 AV5 +0. 07 92 53 9

AV4 +0.10 92 55 9

AV4 +0.08 92 59 6

AV3 +0.10 6

AV4 -0.14 7

AV7 +0. 02 92 61 5

AV5 +0.05 92 65 10 AV8 +0.07 92 67 12 AV4 +0.05 9

AV5 +0.09 10 AV6 +0.05 8

AV7 +0.05 92 69 6

AV3 -0.07 7

AV5 +0.07 7

AV7 +0.07 92 73 9

AVl +0.07 10 AV2 +0. 05 18 AV7 +0.02 92 75 17 AV3 -0.05 92 79 11 AV8 -0.02 7

AV4 -0.05 19 AV3 -0.05 9

AV2 -0.02 92 83 19 AV2 -0.05 92 85 6

AV8 -0.02 13 AV2 -0.11 92 87 16 AV7 -0.05 19 AV3 -0.05 7

AV2 -0.05 92 89 15 AV3 -0.07 92 91 11 AV8 -0.05 7

AVl -0.02 92 99 12 AV8 -0.05 15 AV2 -0.05 92 101 19 AV5 +0.05 9

AV7 +0.05 92 103 10 AV7 +0.07 13 AV8 +0.05 9

AV2 +0.07 92 105 6 AVl +0.07 17 AV3 +0.09 13 AV7 +0.09 L-2019-064 Enclosure Page 36 of 89 Page 20 of 32 ROW COL %TW LOCATION 11 AV8 +0.07 92 107 14 AV4 +0.16 7

AV5 +0.05 10 AV7 +0. 07 92 109 8 AV3 +0.12 11 AV4 +0.10 15 AV7 +0.05 92 111 10 AV3 +0.13 92 92 92 92 92 92 92 92 92 92 93 12 AV4 +0.18 12 AV5 +0. 07 12 113 7 8

115 9 11 117 6 8

11 14 119 8 121 7 123 7 125 7 131 7 135 6 137 7 42 6

AV6 +0.02 AV3 +0.12 AV4 +0.18 AV3 +0.12 AV5 +0.02 AV3 +0.21 AV4 +0.08 AV6 +0.02 AV7 +0.05 AV4 +0.15 AV3 +0.21 AV5 +0.07 AV4 +0.10 AV3 +0.15 AV5 +0.02 AV4 +0.10 AV2 +0.09 5

AV5 +0.05 93 44 7

AV5 +0.05 93 48 7

AV5 +0.00 93 50 6

AV2 +0.09 7

AV5 +0.02 93 52 6

AV4 +0.05 93 56 8

AV4 +0.26 93 60 7

AV3 +0.05 93 62 6

AV3 +0.00 8

AV5 +0.02 93 64 14 AV6 +0.05 8

AV7 +0.09 93 68 8

AV3 +0.07 12 AV4 +0.05 8

AV5 +0.02 12 AV6 +0.09 16 AV7 +0.05 15 AV8 +0.09 93 70 15 AV4 +0.03 19 AV5 +0. 05 14 AV7 +0.02 93 72 11 AVl +0.10 12 AV2 +0.05 9

AV3 +0.05 93 76 16 AV3 -0.07 93 78 19 AV4 -0.05 17 AV3 -0.05 93 80 10 AV8 -0.05 8

AV7 +0.00 7

AV6 -0.05 10 AV5 -0.05 17 AV4 -0.05 8

AV3 -0.07 93 82 10 AV3 -0.07 11 AV2 -0.07 93 88 12 AV8 -0.05 13 AV3 -0.07 12 AV2 -0.05 10 AVl -0.05 93 92 19 AV2 -0.02 93 98 9

AV5 -0.03 8

AV4 -0.02 10 AV3 -0.02 12 AV2 -0. 02 93 100 7 AV2 +0.07

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 9

AV3 +0.09 10 AV5 +0.07 14 AV6 +0.09 93 102 13 AV1 +0.12 17 AV2 +0.07 12 AV7 +0.02 93 104 10 AV8 +0.05 12 AV1 +0.00 13 AV2 +0. 05 93 106 15 AV2 +0.10 10 AV5 +0.02 19 AV6 +0.00 93 108 11 AV2 +0.12 13 AV3 +0.10 12 AV5 +0.07 19 AV6 +0.05 9

AV7 +0.05 93 110 8 AV3 +0.10 11 AV6 +0.05 93 112 11 AV3 +0.07 12 AV4 +0.03 16 AV5 +0.05 16 AV6 +0. 02 19 AV7 +0.02 93 114 16 AV4 +0.05 6

AV5 -0.13 15 AV6 +0.07 7

AV7 +0.05 93 116 7 AV2 +0.10 6

AV3 +0.19 11 AV4 +0.16 10 AV5 -0.05 6

AV7 +0.05 93 118 7 AV2 +0.10 7

AV3 +0.14 93 122 5 AV5 +0.07 93 124 6 AV3 +0.10 93 126 8 AV4 +0.08 93 128 7 AV2 +0.05 5

AV5 +0. 05 94 37 7

AV5 +0.02 94 53 7

AV2 +0.07 94 55 9

AV4 +0.13 8

AV6 +0.05 9

AV7 +0.02 94 57 8

AV5 +0.05 94 59 8

AV4 +0.08 94 61 8

AV2 +0.02 10 AV3 +0.07 11 AV4 +0. 05 10 AV5 +0.02 14 AV6 +0.05 15 AV7 +0.07 94 63 6

AV2 +0.02 11 AV3 +0.09 6

AV4 +0.05 12 AV6 +0.02 94 65 9

AV4 +0.10 11 AV7 +0.14 94 67 7

AV4 +0.05 10 AV5 +0.05 12 AV8 +0.12 94 69 16 AV4 +0.05 12 AV5 +0.05 9

AV6 +0. 07 7

AV7 +0.21 94 71 6

AV2 +0.05 15 AV3 +0.07 7

AV8 +0.07 94 77 15 AV8 -0.02 19 AV7 -0.07 19 AV5 -0.03 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 16 AV3 -0.07 10 AV2 -0.02 94 79 11 AV7 -0.07 16 AV5 -0.05 7

AV4 -0.05 11 AV3 -0.05 18 AV2 -0.05 94 81 6

AV8 -0.02 6

AV4 -0.19 8

AV3 -0.02 94 87 19 AV2 -0.02 94 91 9

AV8 -0.02 94 95 16 AV8 -0.02 11 AV5 +0.02 16 AV2 -0.02 94 97 9

AV7 -0.02 14 AV5 +0.00 8

AV3 -0.02 94 99 6

AV2 -0.09 94 101 17 AV4 +0.11 19 AV7 +0.07 94 107 7 AV5 +0.05 10 AV3 +0.09 12 AV4 +0.11 94 109 11 AV4 +0.11 8

AV7 +0.05 94 111 8 AV3 +0.12 9

AV5 +0.05 18 AV6 +0. 02 94 113 5 AV3 +0.07 7

AV6 +0.00 94 115 6 AV3 +0.09 7

AV4 +0.08 5

AV5 +0.07 94 117 6 AV5 -0.18 94 121 5 AV5 +0.07 5

AV6 +0.00 94 139 7 AV8 -0.11 95 48 6

AV5 +0.00 95 50 5

AV4 +0.26 95 52 9

AV5 +0.02 95 54 6

AV2 +0.07 4

AV3 -0.47 5

AV4 +0.08 95 60 6

AV3 +0.00 95 62 8

AV2 +0.07 9

AV3 +0.05 95 64 7

AV3 +0.07 9

AV4 +0.10 17 AV5 +0.05 16 AV6 +0.07 11 AV7 +0. 02 95 66 5

AV4 +0.10 7

AV6 +0.09 11 AV7 +0.07 95 68 9

AV2 +0.05 14 AV3 +0.10 11 AV4 +0.08 18 AV5 +0.07 11 AV6 +0.09 95 70 5

AV1 +0.05 9

AV2 +0.05 5

AV4 -0.10 10 AV5 +0.07 10 AV7 +0.02 8

AV8 +0.07 95 74 9

AV2 +0.14 11 AV3 +0.12 15 AV4 +0.10 13 AV5 +0.05 13 AV7 +0.05 95 78 19 AV7 -0.02 L-2019-064 Enclosure Page 37 of 89 Page 21 of 32 ROW COL %TW LOCATION 13 AV6 -0. 02 10 AV4 -0.05 13 AV3 -0.07 13 AV2 -0.05 95 80 19 AV5 -0.03 14 AV3 -0.05 5

AV2 -0.02 95 82 13 AV3 -0.05 12 AV2 -0.02 95 84 16 AV7 -0.05 16 AV6 -0.02 95 88 11 AV3 -0.05 9

AV2 -0.02 95 94 6

AV8 -0.05 95 96 16 AV7 -0.05 19 AV3 -0.05 95 98 16 AV7 -0.02 12 AV4 -0.02 15 AV2 +0.00 95 100 7 AV2 +0.09 8

AV3 +0.07 19 AV4 +0.05 11 AV8 +0.09 95 104 12 AV2 +0.07 15 AV4 +0.08 9

AV6 +0.05 14 AV7 +0.09 95 106 7 AV3 +0.14 11 AV4 +0.11 10 AV5 +0.05 16 AV6 +0.07 8

AV7 +0.11 95 108 10 AV3 +0.12 13 AV4 +0.08 8

AV5 +0.07 6

AV6 +0.05 95 110 8 AV4 +0.11 10 AV6 +0.07 95 112 8 AV2 +0.07 7

AV3 +0.15 12 AV7 +0. 05 95 114 7 AV4 +0.13 95 116 9 AV2 +0.09 7

AV3 +0.02 7

AV4 +0.08 95 120 8 AV3 +0.02 95 122 6 AV5 +0.07 95 128 8 AV3 +0.09 14 AV4 +0.05 10 AV5 +0.07 95 130 8 AV2 +0.17 7

AV3 +0.17 96 27 5

AV4 +0.03 5

AV6 +0.02 8

AV2 +0.07 96 49 6

AV4 +0.05 96 53 5

AV2 -0.15 8

AV5 +0.09 96 55 7

AV4 +0.08 7

AV5 +0.00 96 59 9

AV4 +0.15 6

AV7 +0.02 96 61 9

AV7 +0.07 96 63 7

AV4 +0.10 8

AV7 +0. 07 96 65 16 AV3 +0.07 9

AV4 +0.08 17 AV5 +0.09 12 AV6 +0. 07 96 67 16 AV4 +0.13 17 AV7 +0. 05 96 69 12 AV3 +0.12

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear l-19%

ROW COL %TW LOCATION 13 AV6 +0. 07 96 71 15 AV3 +0.14 96 73 8

AV1 +0.20 7

AV2 +0.12 9

AV3 +0.12 96 75 19 AV8 -0.02 11 AV3 -0.05 10 AV2 -0.02 96 77 13 AV7 -0.05 12 AV3 -0.02 7

AV2 -0.02 96 79 18 AV2 -0.02 8

AV1 -0.07 96 81 11 AV3 -0.05 96 91 8

AV2 -0.04 96 95 7

AV7 -0.07 16 AV4 -0.02 11 AV3 +0.00 16 AV2 +0.00 96 97 11 AV8 -0.02 14 AV7 -0.02 8

AV6 +0.00 15 AV5 +0.02 14 AV3 -0.02 6

AV2 -0.02 96 101 17 AV2 +0.07 16 AV4 +0.05 17 AV8 +0.07 96 103 6 AV1 +0.00 10 AV5 +0. 05 16 AV7 +0.02 96 105 7 AV2 +0.14 19 AV3 +0.12 8

AV4 +0.13 9

AV8 +0.12 96 107 11 AV3 +0.07 14 AV4 +0.05 12 AV5 +0. 02 8

AV6 +0.02 9

AV7 +0. 07 96 109 8 AV4 +0.08 7

AV7 +0.07 96 111 8 AV3 +0.07 10 AV5 +0.07 12 AV6 +0.07 9

AV7 +0.02 96 113 6 AV5 +0.02 96 115 6 AV5 +0.07 96 117 6 AV4 +0.05 96 119 8 AV7 +0.07 96 121 7 AV5 +0.07 96 125 7 AV6 +0.02 96 127 8 AV2 +0.05 96 133 7 AV4 +0.11 96 143 7 AV8 +0.09 97 46 6

AV2 +0.09 7

AV5 +0. 05 97 50 8

AV5 -0.13 97 52 9

AV4 +0.08 97 56 7

AV5 +0.14 97 60 7

AV3 +0.12 5

AV5 +0.09 97 62 7

AV3 +0.09 7

AV5 +0.07 7

AV6 +0.05 97 64 10 AV3 +0.14 7

AV4 +0.13 8

AV5 +0.05 97 66 14 AV3 +0.14 9

AV4 +0. 21 97 68 17 AV3 +0.07 97 70 8

AV4 +0.13 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 16 AV5 +0.07 14 AV6 +0.09 8

AV7 +0.02 97 72 6

AV2 +0.07 17 AV3 +0.16 18 AV7 +0.05 8

AV8 +0.07 97 74 5

AV1 +0.02 11 AV4 +0.10 8

AV8 +0.07 97 76 6

AV8 -0.02 15 AV3 -0.05 97 78 7

AV6 +0.00 17 AV5 -0.03 14 AV4 -0.02 18 AV3 -0.02 16 AV2 -0.02 97 80 10 AV7 -0.02 15 AV3 -0.02 7

AV2 +0.00 97 82 13 AV6 -0.05 10 AV5 -0.03 10 AV3 -0.05 12 AV2 -0.05 97 94 7

AV8 -0.02 12 AV7 -0.02 13 AV6 -0.02 16 AV5 +0.00 8

AV4 -0.02 13 AV3 -0.05 8

AV1 -0.02 97 96 9

AV7 +0.00 9

AV2 -0.02 97 98 7

AV8 -0.05 6

AV7 -0.02 7

AV6 -0.07 97 102 12 AV1 +0.07 12 AV4 +0.08 97 106 10 AV2 +0.07 16 AV3 +0.12 18 AV4 +0.08 8

AV6 +0.07 7

AV7 +0. 05 97 108 7 AV2 +0.12 10 AV3 +0.09 18 AV4 +0.08 19 AV5 +0.07 10 AV7 +0.07 97 110 7 AV4 +0.10 97 112 6 AV2 -0.05 6

AV4 +0.11 10 AV5 +0.05 97 114 6 AV4 +0.08 97 116 11 AV2 +0.07 13 AV3 +0.07 12 AV4 +0.08 10 AV5 +0.00 97 120 9 AV6 +0.07 98 45 7

AV4 +0.13 98 53 7

AV2 +0.02 9

AV4 +0.08 98 55 6

AV5 +0.02 98 57 7

AV4 +0.11 98 59 7

AV3 +0.09 98 61 7

AV4 +0.13 98 63 5

AV2 +0.07 7

AV3 +0.12 6

AV4 +0.18 98 65 8

AV3 +0.10 98 67 14 AV5 +0.05 10 AV6 -0.02 9

AV7 +0.02 L-2019-064 Enclosure Page 38 of 89 Page 22 of 32 ROW COL %TW LOCATION 98 69 10 AV5 +0.05 12 AV7 +0. 07 98 71 7

AV2 +0.07 16 AV4 +0.10 16 AV5 +0. 07 11 AV6 +0.07 98 73 6

AV1 +0.21 13 AV2 +0.10 98 75 14 AV3 -0.05 12 AV2 -0.02 98 77 12 AV7 -0.07 12 AV3 -0.05 10 AV2 -0.02 98 79 8

AV7 -0.02 11 AV2 +0.00 98 81 18 AV8 +0.00 15 AV4 -0.05 14 AV2 +0.00 6

AV1 -0.09 98 93 9

AV2 -0.02 98 95 6

AV8 -0.02 7

AV6 -0.05 98 97 13 AV6 +0.00 8

AV3 +0.00 7

AV4 +0.16 98 99 11 AV7 -0.05 7

AV6 -0.26 16 AV5 -0.05 13 AV2 -0.05 98 101 13 AV3 +0.07 10 AV8 +0.07 6

AV2 +0.14 98 105 8 AV8 +0.07 98 107 8 AV7 +0.09 12 AV2 +0.15 17 AV3 +0.14 18 AV4 +0.18 13 AV5 +0.07 98 109 7 AV3 +0.10 8

AV4 +0.19 10 AV7 +0.04 10 AV8 +0.02 98 111 7 AV3 +0.09 12 AV6 +0.05 98 113 8 AV2 +0.10 8

AV3 +0.14 6

AV4 +0.16 9

AV5 +0.10 98 117 8 AV6 +0.07 6

AV7 +0.11 98 119 8 AV3 +0.05 98 121 7 AV4 +0.10 8

AV5 +0.07 98 123 7 AV5 +0.07 8

AV6 +0.07 98 141 7 AV1 +0.23 9

AV6 +0. 05 98 143 7 AV1 +0.05 99 54 6

AV2 +0.07 6

AV3 +0.07 99 56 6

AV4 +0.08 99 62 7

AV5 +0.00 99 64 6

AV2 +0.00 6

AV3 -0.12 8

AV4 +0.10 99 66 7

AV4 +0.10 8

AV6 +0. 05 99 68 10 AV3 +0.10 16 AV5 +0.05 16 AV7 +0.02 5

AV2 -0.09 99 70 13 AV3 +0.09

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 10 AV4 +0.13 8

AV7 +0.05 99 72 19 AV4 +0.13 12 AV7 +0.05 99 74 5

AVl +0.05 6

AV2 +0. 02 7

AV3 +0.07 14 AVS +0.09 99 76 17 AV3 -0.02 99 78 14 AVS +0.00 13 AV5 +0.00 19 AV4 -0.02 99 80 10 AV6 -0.02 6

AV5 -0.08 12 AV3 -0.05 6

AV2 -0.09 99 82 10 AV7 -0.05 7

AV6 -0.05 19.

  • AV5 -0. 03 16 AV4 -0.05 6

AV3 -0.05 8

AV2 -0.02 5

AVl -0.05 99 96 6

AV7 +0.00 10 AV6 -0.02 18 AV4 -0.05 7

AV2 +0.00 99 98 7

AV5 +0.00 16 AV4 +0.00 14 AV3 +0.00 17 AV2 +0.02 99 104 8 AV2 +0.10 7

AV3 +0.16 11 AV4 +0.18 99 106 8 AV3 +0.14 7

AV4 +0.16 16 AV7 +0.04 12 AV8 +0.05 99 108 8 AV3 +0.12 12 AV4 +0.16 10 AV5 +0.07 99 110 8 AV4 +0.16 7

AV5 +0.09 11 AV6 +0. 07 99 112 9 AV6 +0.07 8

AV2 +0.12 8

AV4 +0.05 99 114 6 AV3 +0.07 11 AV4 +0. 08 11 AV8 +0. 05 99 116 5 AV3 +0.09 6

AV5 +0.05 99 118 7 AV2 +0.10 7

AV5 +0. 07 99 122 7 AV5 +0.05 99 126 6 AV2 +0.13 99 130 7 AV3 +0.12 100 49 7

AV5 +0.07 100 63 6

AV2 +0.02 100 65 14 AV3 +0.12 7

AV4 +0.16 100 67 5

AVl +0.05 13 AV3 +0. 07 19 AV5 +0. 02 19 AV6 +0. 00 100 69 7

AV3 +0.10 9

AV5 +0.05 19 AV6 +0.07 10 AV8 +0.02 100 71 17 AV3 +0.10 13 AV4 +0.10 100 73 8

AV4 +0.05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 100 75 7

AVS +0.00 100 77 18 AV2 +0.00 100 79 15 AV7 -0.05 100 81 12 AV8 -0.02 10 AV4 -0.07 19 AV3 -0.07 12 AV2 -0.02 100 91 9

AVS -0.02 15 AV3 -0.05 15 AV2 -0.05 100 95 16 AV4 -0.05 6

AV3 -0.05 19 AV2 +0.00 100 97 8

AV7 -0.05 16 AV5 -0.03 14 AV4 -0.05 15 AV3 -0.02 7

AV2 -0.02 100 99 14 AVS -0.05 18 AV6 -0.02 6

AV4 +0. 00 18 AV3 -0.05 11 AV2 -0.02 100 101 13 AV2 +0.05 17 AV4 +0.08 12 AV7 +0. 07 100 105 16 AV3 +0.12 9

AVS +0.07 100 107 15 AV2 +0.12 100 109 8 AV4 +0.03 100 111 7 AV4 +0.03 12 AV6 +0.05 100 115 7 AV4 +0.11 5

AV5 +0.02 100 121 6 AVl +0.07 8

AV2 +0.12 9

AV3 +0.12 6

AV4 +0.13 9

AV5 +0.07 100 125 7 AV2 +0.07 100 129 8 AV5 +0.07 101 52 7

AV3 +0.12 8

AV4 +0.10 8

AV5 +0.05 101 58 8

AV4 +0.08 101 60 6

AV5 +0.25 101 70 14 AV4 +0.05 13 AV5 +0.07 8

AV2 +0.09 101 72 6

AVl +0.05 10 AV2 +0.05 14 AV3 +0.09 101 74 11 AV2 +0.12 8

AV7 +0.07 9

AVS +0.07 101 76 11 AV2 +0.00 101 78 16 AV5 -0.05 5

AV4 -0.21 16 AV3 -0.05 10 AV2 -0.05 101 80 14 AVS +0.00 19 AV7 -0.05 16 AV3 -0.07 101 82 11 AVS -0.05 10 AV3 -0.07 101 88 17 AV7 -0.05 12 AV1 -0.05 12 AVS -0.05 101 90 19 AV4 -0.07 6

AVl +0.00 101 94 6

AV6 -0.16 18 AV5 -0.05 L-2019-064 Enclosure Page 39 of 89 Page 23 of 32 ROW COL %TW LOCATION 11 AV4 -0.07 15 AV3 -0.07 16 AV2 -0.05 8

AVl -0.05 101 96 15 AV7 +0.00 9

AV6 +0.00 6

AV5 -0.05 16 AV4 -0.02 101 98 9

AV7 -0.02 7

AV6 -0.07 17 AV5 -0.03 14 AV3 -0.02 14 AV4 +0.00 101 100 8 AVl +0.07 12 AV3 +0.14 11 AV4 +0.13 12 AV5 +0.02 8

AV7 +0.05 101 106 6 AV4 +0.06 5

AV5 +0.02 101 108 9 AV4 +0.05 12 AV5 +0.05 101 110 6 AV2 +0.02 13 AV3 +0.05 14 AV4 +0.11 9

AV5 +0.09 101 112 6 AV7 +0.07 101 120 7 AV5 +0.02 101 128 7 AV5 +0.02 102 39 8

AV6 +0.07 102 43 6

AV5 +0.05 102 45 7

AV5 +0.09 102 51 7

AV4 +0.10 7

AV5 +0.05 8

AV6 +0.05 102 55 9

AV4 +0.08 102 59 7

AV2 +0.10 10 AV3 +0.10 8

AV4 +0.16 102 71 9

AV2 +0.07 16 AV3 +0.09 102 73 12 AV2 +0.07 17 AV3 +0.14 15 AV4 +0.10 19 AV6 +0.05 102 75 10 AVS +0.00 17 AV4 -0.07 16 AV3 -0.05 102 77 13 AV7 -0.05 18 AV3 -0.07 15 AV2 -0.05 102 79 19 AVS +0.00 10 AV6 +0.00 8

AV4 -0.05 102 91 18 AV6 -0.02 14 AV3 -0.05 9

AV2 -0.05 6

AVl -0.05 102 95 19 AV7 -0.05 15 AV5 -0.05 10 AV3 -0.07 13 AV2 -0.02 102 97 5

AV7 -0.05 6

AV6 -0.05 16 AV5 -0.03 12 AV3 -0.02 102 99 5

AV8 -0.07 9

AV7 -0.02 13 AV3 -0.05 11 AV2 -0.02 102 105 10 AV3 +0.12 13 AV4 +0.10

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 15 AV6 +0.09 15 AV7 +0.09 102 107 7 AV3 +0.12 7

AV6 +0.10 6

AV7 +0.07 102 111 7 AV2 +0.05 7

AV3 +0.07 7

AV4 +0.08 6

AV5 +0.05 10 AV6 +0.02 102 113 7 AV3 +0.07 6

AV4 +0.03 102 115 8 AV3 +0.09 9

AV5 +0.05 102 123 12 AV6 +0.05 102 125 7 AV6 +0.00 103 44 6

AV5 +0.05 103 46 11 AV5 +0,05 103 48 7

AV5 +0.05 103 54 9

AV5 +0.07 103 56 15 AV2 +0.12 16 AV3 +0.14 10 AV4 +0.16 8

AV5 +0.12 103 60 5

AV3 +0.07 9

AV4 +0.10 103 64 6

AV4 +0.13 7

AV7 +0.09 103 66 7

AV6 +0.02 103 70 16 AV4 +0.13 15 AV5 +0.07 14 AV6 +0.05 103 72 7

AV2 +0.09 14 AV3 +0.12 103 78 19 AV2 -0.02 7

AV7 -0.02 103 80 15 AV8 +0.00 7

AV5 -0.03 15 AV4 -0.05 19 AV3 -0.05 5

AV2 -0.02 103 82 18 AV3 -0.02 14 AV2 +0.00 103 90 12 AV8 -0.02 17 AV3 -0.07 12 AV2 -0.02 103 92 13 AV8 -0.02 19 AV2 -0.05 8

AV1 -0.02 103 94 17 AV8 -0.02 7

AV2 +0.00 103 96 10 AV8 +0.00 18 AV4 -0.05 17 AV3 -0.05 7

AV2 -0.11 103 98 7

AV7 -0.02 7

AV6 -0.19 17 AV5 -0.03 17 AV4 -0.02 11 AV3 -0.07 103 100 11 AV2 +0.07 103 104 6 AV3 +0.09 103 106 13 AV3 +0.07 9

AV4 +0.08 6

AV6 +0.07 6

AV2 +0.07 103 108 8 AV4 +0.08 6

AV5 +0.02 103 110 7 AV6 +0.10 103 112 13 AV2 +0.05 9

AV3 +0.07 103 114 7 AV3 +0.09 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 6

AV5 +0.05 13 AV6 +0.05 103 116 7 AV7 +0.07 104 49 12 AV5 +0.02 104 71 10 AV2 +0.05 7

AV3 +0.09 14 AV4 +0.05 6

AV6 +0.05 104 73 14 AV5 +0.05 18 AV7 +0.02 9

AV2 +0.02 18 AV3 +0.07 104 75 10 AV8 +0.00 18 AV2 -0.02 104 77 16 AV7 -0.05 15 AV5 -0.03 15 AV3 -0.02 104 79 13 AV6 -0.02 14 AV5 -0.03 14 AV3 -0.02 13 AV2 -0.07 104 81 13 AV6 -0.05 7

AV5 -0.05 12 AV4 -0.05 7

AV2 -0.02 104 91 13 AV1 -0.05 104 95 9

AV6 -0.02 11 AV5 +0.00 19 AV4 -0.02 7

AV3 -0.05 11 AV2 -0.02 6

AV1 +0.00 104 97 8

9 104 99 6

AV7 -0.02 AV3 -0.05 AV8 -0.02 10 AV7 -0.05 10 AV6 -0.02 12 AV5 -0.03 18 AV4 +0.00 7

AV3 -0.05 11 AV2 -0.05 104 105 7 AV2 +0.05 8

AV3 +0.12 17 AV4 +0.18 104 107 6 AV2 +0.07 8

AV3 +0.16 8

AV4 +0.18 10 AV7 +0.07 104 109 6 AV4 +0.16 104 111 7 AV6 +0.05 104 117 9 AV3 +0.09 6

AV5 +0.05 105 52 17 AV2 +0.07 16 AV3 +0.07 15 AV4 +0.08 10 AV5 +0.07 105 60 5

AV3 +0.02 105 62 5

AV7 -0.09 105 66 6

AV3 +0.05 105 70 10 AV5 +0.07 105 72 9

AV2 +0.05 15 AV3 +0.05 16 AV6 +0. 07 8

AV7 +0.09 105 74 10 AV2 +0.09 19 AV3 +0.07 105 76 16 AV3 -0.07 8

AV2 -0.05 105 78 7

AV7 -0.02 9

AV5 -0.03 15 AV3 -0.05 6

AV2 -0.05 L-2019-064 Enclosure Page 40 of 89 Page 24 of 32 ROW COL %TW LOCATION 105 80 12 AV8 -0.02 12 AV4 -0.07 8

AV3 -0.05 6

AV2 -0.05 105 82 15 AV7 -0.05 11 AV2 -0.02 105 94 16 AV8 +0.02 19 AV2 -0.02 105 96 10 AV6 -0.02 18 AV4 -0.05 12 AV3 -0.07 105 98 15 AV7 -0.05 17 AV4 -0.05 18 AV3 -0.07 6

AV2 -0.02 105 100 9 AV3 +0.12 16 AV6 +0.07 10 AV7 +0.05 9

AV8 +0.09 105 104 8 AV3 +0.16 10 AV4 +0.19 14 AV5 +0.07 18 AV6 +0.07 105 106 7 AV3 +0.12 10 AV5 +0.07 105 108 7 AV4 +0.13 7

AV5 +0.05 105 112 8 AV1 +0.09 9

AV2 +0. 07 10 AV3 +0.10 7

AV4 +0.11 7

AV5 +0.09 105 114 7 AV3 +0.09 8

AV4 +0.08 8

AV5 +0.07 105 122 8 AV5 +0.05 106 45 6

AV5 +0.07 106 53 11 AV5 +0.05 8

AV6 +0.07 106 57 8

AV5 +0.16 106 63 5

AV3 +0.12 106 67 6

AV6 +0.00 106 69 8

AV7 +0.09 106 71 8

AV2 +0.07 6

AV3 +0.07 15 AV4 +0.08 14 AV6 +0. 07 106 73 6

AV1 +0.07 7

AV2 +0.09 15 AV3 +0.05 16 AV8 +0.07 106 75 18 AV4 -0.02 8

AV3 -0.02 106 79 18 AV4 +0.03 13 AV2 +0.00 6

AV1 -0.05 106 93 7

AV8 -0.07 12 AV7 -0.05 9

AV3 -0.02 10 AV2 -0.02 106 95 16 AV2 -0.02 7

AV1 +0.00 11 AV8 +0.00 18 AV3 -0.07 106 97 11 AV7 -0.05 15 AV4 -0.02 10 AV2 -0.02 8

AV1 +0.00 106 99 19 AV4 -0.05 7

AV3 -0.02 7

AV1 -0.02 15 AV7 +0.00

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 106 101 14 AV6 +0.07 13 AV7 +0.05 9

AV3 +0.14 18 AV5 +0.05 106 103 7 AV2 +0.10 19 AV3 +0.09 8

106 105 7 106 107 7 7

106 111 6 106 113 5 5

9 106 115 8 106 121 6 106 133 7 107 34 6

107 44 8

AV7 +0. 07 AV4 +0. 05 AV3 +0.10 AV5 +0.05 AV4 +0.13 AV2 +0. 05 AV3 +0.05 AV4 +0. 03 AV2 +0. 02 AV5 +0.05 AV5 +0.05 AV1 +0.17 AV5 +0. 02 107 50 12 AV4 +0.05 8

AV5 +0.00 10 AV2 +0.05 12 AV3 +0.09 107 66 5

AV3 +0.09 5

AV4 +0.05 7

AV6 +0.02 107 68 6

AV3 +0.14 11 AV4 +0.13 9

AV5 +0.00 18 AV6 +0.05 8

AV8 +0.02 107 76 9

AV8 +0.00 19 AV6 -0.05 9

AV5 -0.05 12 AV4 -0.07 8

AV2 -0.02 107 78 15 AV7 -0.05 16 AV6 -0.05 8

AV5 -0.05 9

AV4 -0.05 16 AV3 -0.07 9

AV2 -0.05 107 86 19 AV5 -0.05 14 AV2 -0.07 107 90 17 AV8 +0.00 18 AV3 -0.07 14 AV2 -0.05 107 96 8

AV8 -0.05 6

AV5 +0.00 16 AV4 -0.02 14 AV2 -0.02 10 AV1 +0.00 107 98 17 AV6 -0.02 12 AV4 -0.05 8

AV2 -0.02 107 100 7 AV2 +0.07 11 AV3 +0.14 11 AV6 +0.07 8

AV7 +0.07 107 102 6 AV2 +0.10 17 AV4 +0.13 18 AV5 +0.07 6

AV7 +0.07 107 104 14 AV3 +0.09 11 AV4 +0.16 8

AV5 +0. 05 7

AV7 +0. 05 107 106 5 AV3 +0.07 6

AV7 +0.04 107 108 9 107 110 7 107 112 9 AV6 +0. 05 AV6 +0.12 AV2 +0. 07 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 9

AV3 +0.14 6

AV5 +0.02 9

AV7 +0.09 107 114 6 AV4 +0.16 107 120 9 AV6 +0.09 13 AV2 +0.10 108 35 10 AV5 +0.09 8

AV8 +0.14 108 37 8

AV8 +0.09 108 49 9

AV5 +0.05 108 51 5

AV5 -0.39 108 53 6

AV4 +0.05 108 69 12 AV2 +0.05 14 AV7 +0.07 108 71 18 AV2 +0.05 18 AV3 +0.16 9

AV7 +0.11 108 73 11 AV1 +0.10 16 AV2 +0.14 16 AV3 +0.14 16 AV4 +0.15 14 AV5 +0.05 108 75 16 AV4 -0.07 6

AV3 -0.05 108 77 7

AV8 -0.02 108 79 14 AV6 -0.05 17 AV5 -0.05 17 AV4 -0.09 9

AV3 -0.05 108 81 15 AV8 -0.05 19 AV4 -0.05 108 91 11 AV1 -0.02 108 93 6

AV8 -0.05 7

AV1 -0.02 108 97 14 AV6 -0.02 14 AV5 -0.03 18 AV4 -0.02 8

AV3 -0.05 108 99 9

AV7 -0.02 11 AV1 -0.05 108 101 8 AV1 +0.05 11 AV4 +0.08 7

AV6 +0.09 13 AV7 +0.07 108 103 7 AV2 +0.05 12 AV5 +0.00 13 AV7 +0.11 7

AV8 +0.09 108 105 7 AV3 +0.09 13 AV4 +0.13 18 AV5 +0.02 11 AV7 +0.07 108 107 8 AV3 +0.07 6

AV4 +0.11 108 109 7 AV3 +0.12 6

AV5 +0. 07 108 127 6 AV4 +0.05 108 131 9 AV5 +0.05 108 135 6 AV8 +0.02 109 54 7

AV4 +0.16 109 56 10 AV5 +0.14 109 60 7

AV3 +0.12 7

AV5 +0.07 109 64 7

AV4 +0.10 109 66 7

AV5 +0.05 109 68 9

AV1 +0.10 16 AV4 +0.10 17 AV6 +0.07 9

AV8 +0.09 109 70 7

6 9

AV1 +0.10 AV2 +0.12 AV3 +0.09 L-2019-064 Enclosure Page 41 of 89 Page 25 of 32 ROW COL %TW LOCATION 10 AV4 +0.16 15 AV7 +0.07 109 74 6

AV2 +0.07 8

AV3 +0.12 109 76 9

AV5 +0.02 16 AV3 -0.02 9

AV2 +0. 02 109 82 12 AV1 -0.02 9

AV8 +0.00 109 88 15 AV8 -0.02 12 AV3 -0.07 11 AV2 -0.02 109 92 10 AV2 -0.07 12 AV8 +0. 00 9

AV5 -0.03 109 94 7

5 AV7 -0.05 AV4 -0.07 11 AV3 -0.09 17 AV2 -0.02 7

109 96 8

AV1 -0.05 AV5 -0.03 16 AV4 -0.07 12 AV3 -0.07 109 98 8

AV4 -0.02 17 AV3 -0.05 6

AV2 +0. 00 7

AV7 -0.05 18 AV5 -0.03 109 100 6 AV3 +0.09 15 AV8 +0.09 109 102 6 AV2 +0.05 109 104 11 AV3 +0.12 12 AV4 +0.14 8

AV5 +0.02 12 AV6 +0.07 11 AV7 +0.07 109 106 7 AV3 +0.09 6

AV5 +0.05 109 108 8 AV5 +0.05 109 112 6 AV3 +0.10 109 116 6 AV5 +0.05 6

AV4 +0.11 110 45 10 AV5 +0.09 110 47 10 AV5 +0.05 110 57 6

AV4 +0.03 110 65 7

AV2 +0.05 7

AV4 +0.11 8

AV6 +0.07 110 67 6

AV2 +0.07 6

AV6 -0.09 110 69 7

AV2 +0.05 5

AV3 +0.07 7

AV4 +0. 05 18 AV5 +0.07 110 71 7

AV1 +0.02 110 75 7

AV8 -0.05 12 AV6 +0.00 110 77 12 AV8 +0.00 11 AV2 +0.00 110 79 11 AV8 +0.00 12 AV3 -0.05 13 AV2 -0.02 110 81 17 AV6 -0.05 10 AV3 -0.07 8

AV2 -0.02 110 93 8

AV7 +0.00 6

AV1 -0.02 110 95 16 AV5 -0.03 19 AV3 -0.07 10 AV1 -0.05 110 97 7

AV6 -0.07 110 99 7

AV7 -0.02

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 19 AV4 -0.02 17 AV3 -0.07 8

AV2 -0.07 110 101 17 AV5 +0.05*

110 103 7 AV1 +0. 02 15 AV2 +0. 07 110 105 11 AV6 +0.07 110 109 7 AV3 +0.12 7

AV4 +0.11 7

AV5 +0.02 110 111 7 AV6 +0.05 110 113 10 AV3 +0.12 110 115 8 AV4 +0.16 110 117 7 AV6 +0.07 110 119 7 AV3 +0.14 7

AV5 +0.09 110 123 8 AV2 +0.10 111 46 6

AV5 +0.07 111 56 11 AV7 +0.02 111 62 7

AV3 +0.09 8

AV7 +0.05 111 66 6

AV3 -0.07 111 68 5

AV1 -0.09 5

AV2 +0.05 9

AV8 +0.07 111 70 7

AV3 +0.07 9

AV4 +0.08 18 AV5 +0.12 6

AV6 +0.12 111 72 7

AV3 +0.19 8

AV4 +0.13 14 AV5 +0.02 111 74 17 AV4 +0.03 10 AV7 +0.09 111 76 19 AV5 -0.05 16 AV4 -0.07 7

AV3 -0.07 6

AV2 -0.05 111 80 18 AV4 -0.07 111 82 16 AV6 -0.05 15 AV3 -0.07 6

AV2 -0.05 111 86 8

AV8 +0.05 12 AV7 -0.02 15 AV1 -0.07 111 94 15 AV4 +0.03 11 AV1 -0.02 111 98 8

AV7 -0.03 7

AV6 +0.00 8

AV4 +0.03 7

AV3 -0.02 6

AV2 -0.05 7

AV1 -0.02 111 100 6 AV2 +0.12 8

AV3 +0.12 8

AV4 +0.10 11 AV5 +0.05 111 104 7 AV2 +0.07 12 AV3 +0.18 12 AV4 +0.21 9

AV5 +0.05 6

AV7 +0.07 6

AV8 +0.09 111 106 6 AV2 +0.07 7

AV3 +0.12 9

AV4 +0.16 7

AV5 +0.02 9

AV6 +0.09 14 AV7 +0.11 111 108 8 AV6 +0.07 111 110 7 AV2 +0.10 6

AV3 +0. 05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 111 126 9 AV5 +0.05 112 41 5

AV3 +0.09 5

AV5 +0. 07 7

AV6 +0. 05 112 43 6

AV2 +0.02 5

AV5 +0.05 112 45 7

AV5 +0.05 112 49 8

AV5 +0.02 112 51 6

AV4 +0.03 10 AV5 +0. 02 112 61 7

AV5 +0.02 112 67 8

AV3 +0.19 6

AV5 -0.03 6

AV6 -0.42 112 69 7

AV3 +0.14 8

AV4 +0.10 17 AV5 +0.07 11 AV7 +0. 07 112 71 5

AV3 -0.07 7

AV4 +0.05 112 73 6

AV2 +0.09 9

AV3 +0.05 17 AV5 +0.05 13 AV7 +0. 05 14 AV8 +0.09 112 75 14 AV7 -0.02 14 AV6 -0.05 14 AV4 -0.02 8

AV3 -0.05 7

AV2 -0.05 112 77 18 AV4 -0.07 6

AV3 -0.09 112 79 13 AV8 +0.00 18 AV2 -0.02 6

AV1 -0.07 112 81 8

AV7 -0.05 18 AV4 -0.07 15 AV3 -0.07 8

AV2 -0.02 112 83 10 AV8 +0.00 12 AV2 -0.05 112 87 12 AV8 +0.02 7

AV1 -0.02 112 93 18 AV5 -0.03 112 95 11 AV4 -0.05 8

AV3 -0.05 7

AV1 -0.02 112 97 11 AV5 -0.03 17 AV4 -0.02 15 AV2 -0.05 6

AV1 +0.00 112 99 13 AV7 +0.00 18 AV6 +0.02 15 AV5 +0. 02 14 AV4 +0.03 6

AV1 -0.02 112 103 13 AV2 +0.07 9

AV6 +0.09 112 105 8 AV5 +0.14 112 107 9 AV3 +0.10 112 109 7 AV2 +0.07 7

AV3 +0.14 112 115 7 AV5 +0.05 112 121 7 AV5 +0.05 112 127 7 AV5 +0.02 113 50 6

AV2 +0.10 8

AV4 +0.10 8

AV5 +0.00 113 56 5

AV2 +0.07 6

AV4 +0.13 113 62 5

AV3 +0.09 113 70 8

AV3 +0.05 L-2019-064 Enclosure Page 42 of 89 Page 26 of 32 ROW COL %TW LOCATION 113 74 14 AV2 +0.10 18 AV3 +0.10 9

AV7 +0.11 113 76 9

AV4 -0.07 10 AV2 -0.02 113 78 12 AV8 +0.00 14 AV3 -0.05 13 AV2 -0.05 113 80 8

AV5 +0.00 19 AV4 -0.02 16 AV2 -0.05 113 88 18 AV3 -0.09 10 AV2 -0.02 113 90 12 AV2 -0.05 113 94 7

AV7 +0.00 12 AV4 -0.05 9

AV3 -0.09 7

AV1 -0.02 113 96 11 AV3 -0.07 9

AV2 -0.07 113 98 14 AV5 -0.03 7

AV4 -0.09 7

AV3 -0.07 113 100 6 AV1 +0.12 7

AV3 +0.14 15 AV4 +0.13 7

AV5 +0.05 8

AV6 +0.07 6

AV7 +0.05 113 102 10 AV4 +0.18 14 AV5 +0.07 9

AV7 +0. 07 113 108 10 AV2 +0.07 11 AV6 +0. 07 113 110 8 AV6 +0.07 113 114 8 AV4 +0.13 7

AV6 +0.05 113 120 6 AV2 +0.05 7

AV3 +0.07 9

AV4 +0.08 113 122 10 AV4 +0.16 113 124 7 AV3 +0.14 9

AV4 +0.16 114 41 10 AV5 +0.02 114 49 8

AV7 +0.05 7

AV4 +0.10 114 59 13 AV5 +0.05 114 67 16 AV6 +0.09 16 AV7 +0.07 114 69 7

AV7 +0.23 114 71 6

AV3 +0.07 9

AV4 +0.13 11 AV5 +0.02 114 75 10 AV3 -0.05 7

AV8 -0.07 14 AV7 -0.02 15 AV6 -0.05 114 77 7

AV7 -0.02 12 AV6 +0.00 13 AV5 +0.00 16 AV4 -0.05 11 AV2 +0.00 114 79 19 AV4 -0.07 12 AV3 -0.05 6

AV8 -0.02 114 81 17 AV2 -0.05 10 AV7 -0.02 13 AV6 -0.05 14 AV5 -0.03 17 AV4 -0.07 114 87 16 AV7 -0.02 17 AV6 +0.00

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 19 AV2 -0.07 114 91 19 AVS +0.00 17 AV2 +0.00 114 93 7

AV7 -0.02 12 AV6 +0.12 18 AV5 -0.03 12 AV4 -0.05 14 AV2 -0.05 12 AV3 +0.00 114 95 9

AV7 -0.05 7

AV5 -0.05 14 AV3 -0.05 7

AV2 -0.07 114 97 7

AV6 -0.02 13 AV5 -0.05 7

AV4 -0.05 11 AV3 -0.07 114 101 8 AV2 +0.18 10 AV3 +0.19 16 AV6 +0.07 18 AV7 +0.07 114 103 7 AV4 +0.08 9

AV5 +0.02 14 AV6 +0. 05 14 AV7 +0.07 6

AV8 -0.07 114 105 10 AV6 +0.09 114 107 6 AV3 +0.07 9

AV4 +0.13 6

AV5 +0.07 114 111 8 AV3 +0.07 6

AV6 +0. 02 114 119 7 114 125 6 6

7 115 40 7

115 42 115 48 115 52 115 58

' 115 60 115 66 115 70 115 72 115 74 115 76 115 80 115 82 115 92 5

9 8

7 10 8

8 8

7 7

17 13 14 9

12 7

8 12 10 5

7 9

17 12 12 18 10 11 7

7 6

9 19 13 15 AV7 +0. 07 AV2 +0.05 AV4 +0.06 AV5 +0.07 AV2 +0.02 AV5 +0. 02 AV6 +0.05 AV6 +0. 05 AV4 +0.10 AV5 +0.05 AV6 +0.07 AV2 +0.10 AV3 +0.17 AV5 +0.09 AVl +0.07 AV3 +0.21 AV4 +0.26 AV5 +0.16 AVB +0.14 AV2 +0.12 AV3 +0.16 AV4 +0.16 AV5 +0.07 AV6 +0.12 AVl +0.07 AV2 +0.05 AV3 +0.14 AV7 +0. 07 AV8 +0.09 AV1 +0.12 AV4 +0.13 AV5 +0.07 AV7 +0.09 AV7 -0.02 AV3 -0.05 AV2 +0.00 AV8 +0.00 AV7 -0.02 AV2 -0.05 AV7 -0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 19 AV6 -0.02 18 AV3 -0.09 19 AV2 -0.02 115 94 9

AV6 -0.21 7

AV3 -0.09 115 96 7

AV6 -0.05 7

AV5 -0.05 12 AV4 -0.09 11 AV3 -0.05 9

AV2 -0.09 7

AV1 -0.05 115 102 15 AV1 +0.07 17 AV4 +0.13 17 AV5 +0.12 10 AV6 +0.09 115 104 6 AVl +0.07 7

AV3 +0.12 8

AV4 +0.11 14 AV6 +0.05 11 AV7 +0.09 7

AV8 +0.14 115 126 7 AV3 +0.09 10 AV4 +0.11 115 130 7 AV4 +0.08 7

AV7 +0.09 116 41 6

AV6 +0.07 116 47 6

AV3 +0.09 6

AV5 +0.05 116 51 7

AV7 +0.09 116 57 10 AV3 +0.05 9

AV4 +0.08 9

AV5 +0.07 116 59 11 AV5 +0.02 116 61 7

AV2 +0.15 7

AV3 +0.09 8

AV4 +0.15 5

AV5 +0.16 7

AV6 +0. 02 116 69 5

AV3 +0.07 7

AV6 +0. 07 116 73 9

AV6 +0.23 116 75 8

AV6 -0.07 13 AV5 -0.08 8

AV4 -0. 12 11 AV3 -0.07 11 AV2 -0.02 116 77 13 AV7 -0.05 16 AV6 -0.05 16 AV5 -0.05 6

AV4 -0.09 116 81 12 AV7 -0.02 12 AV2 -0.05 116 91 14 AV7 -0.05 18 AV4 -0.07 12 AV3 -0.07 11 AV2 -0.02 116 93 19 AV7 -0.02 18 AV6 +0.00 7

AV4 -0.05 13 AV2 -0.02 8

AV1 -0.05 116 95 19 AV7 -0.02 9

AV4 -0.09 18 AV3 -0.07 116 97 9

AV3 -0.05 8

AV2 +0.00 116 99 7

AV6 +0.02 6

AV3 +0.00 7

AV2 -0.02 5

AV1 -0.05 116 103 6 AV2 +0.07 116 129 6 AV4 +0.08 L-2019-064 Enclosure Page 43 of 89 Page 27 of 32 ROW COL %TW LOCATION 9

AV5 +0.02 8

AV6 +0.05 8

AV8 +0.09 117 44 7

AV2 +0.14 12 AV5 +0.07 8

AV6 +0.05 117 46 9

AV6 +0.05 117 48 5

8 117 58 9

AV4 +0.05 AV5 +0. 02 AV5 +0.05 117 62 6

AV7 -0.02 117 64 7

AV6 +0.05 117 68 13 AV2 +0.07 12 AV3 +0.12 14 AV4 +0.08 16 AV7 +0.05 117 70 6

AV3 +0.07 6

AV5 +0.00 18 AV7 +0.05 117 72 8

AV8 +0.12 117 76 14 AV7 -0.02 12 AV5 -0.03 117 80 12 AVB +0.00 8

AV4 -0.05 8

AV3 -0.09 11 AV2 -0.05 117 92 14 AV7 -0.05 19 AV5 -0.08 6

AV1 -0.05 117 94 18 AV7 -0.02 18 AV4 +0.03 11 AV3 -0.05 7

AV2 -0.05 117 96 10 AV6 -0.05 117 98 10 AV5 -0.05 18 AV3 -0.07 7

AV2 -0.02 117 120 7 AV4 +0.10 5

AV6 +0. 07 4

8 117 124 15 118 69 7

118 73 11 17 118 77 15 13 8

13 7

118 79 15 7

118 81 9

7 12 12 118 91 10 6

19 16 118 93 12 14 13 11 118 101 7 118 109 7 118 127 10 7

7 7

6 119 54 7

AV7 +0.09 AV3 +0.09 AV6 +0.09 AV7 +0.23 AV5 +0.05 AV6 +0. 07 AV7 -0.02 AV4 -0.09 AV3 -0.05 AV2 -0.02 AV1 -0.07 AV6 -0.05 AV5 -0.05 AV3 -0.09 AV2 -0.02 AV7 -0.02 AV4 -0.05 AV8 +0.05 AV7 -0.02 AV4 -0.05 AV2 +0. 00 AV7 -0.02 AV6 +0.00 AV5 -0.05 AV3 -0.09 AV4 +0. 05 AV6 +0.05 AV2 +0.10 AV3 +0.14 AV4 +0.11 AV5 +0.05 AV7 +0. 07 AV6 +0.05

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 8

AV7 +0.05 119 72 5

AV1 +0.05 9

AV2 +0.07 11 AV3 +0. 09 18 AV5 +0.14 8

AV6 +0.26 119 74 9

AV1 +0.05 11 AV2 +0.07 7

AV3 +0.07 9

AV4 +0.08 18 AV6 +0.09 11 AV7 +0.09 119 76 19 AV7 +0.00 16 AV4 -0.07 119 78 12 AV8 +0.02 13 AV7 +0.00 11 AV6 -0.02 6

AV5 -0.08 6

AV4 -o.o2 6

AV3 -0.05 119 80 18 AV8 +0.00 13 AV5 -0.03 7

AV4 -0.05 8

AV2 -0.05 119 88 11 AV8 -0.02 17 AV6 -0.02 10 AV5 -0.05 6

AV2 -0.18 11 AV1 +0.00 119 94 6

AV6 -0.21 9

AV2 -0.05 119 96 6

AV6 -0.12 11 AV4 +0.05 10 AV3 +0.05 13 AV2 +0.02 9

AV1 -0. 02 119 100 7 AV2 +0.19 11 AV3 +0.21 12 AV4 +0.18 13 AV5 +0.12 119 106 6 AV4 +0.03 5

AV5 +0. 05 119 122 7 AV2 +0.15 8

AV3 +0.14 9

AV4 +0.08 9

AV6 +0.07 7

AV7 +0.04 120 71 7

AV7 +0.05 120 73 11 AV6 +0.09 120 75 8

AV7 -0.02 120 77 6

AV2 -0.05 120 79 7

AV8 -0.05 11 AV6 -0.02 6

AV4 -0.09 6

AV3 -0.07 120 81 16 AV8 +0.00 8

AV4 -0.05 8

AV3 -0.07 120 91 12 AV7 -0.02 12 AV6 -0.02 17 AV3 -0.09 18 AV2 -0.05 120 93 8

AV5 +0.02 13 AV2 -0.05 120 95 11 AV7 +0.02 7

AV2 -0.02 120 97 13 AV7 -0.05 19 AV6 -0.05 15 AV5 -0.05 9

AV4 -0.11 16 AV3 -0.07 11 AV2 -0.07 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 120 99 13 AV7 -0.02 8

AV1 -0.02 120 103 16 AV2 +0.02 7

AV3 +0. 05 14 AV4 +0.00 11 AV6 +0.05 120 105 9 AV4 +0.16 7

AV5 +0.07 10 AV6 +0.09 120 107 8 AV4 +0.16 7

AV5 +0.12 8

AV6 +0.10 9

AV7 +0.14 120 111 7 AV3 +0.05 9

AV4 +0.03 6

AV5 +0.07 120 123 6 AV2 +0.09 14 AV3 +0.09 7

AV4 +0.14 10 AV5 +0. 07 14 AV6 +0.09 7

AV8 +0.02 121 76 7

AV6 +0.00 121 78 10 AV7 +0.02 8

AV4 +0.00 7

AV3 +0. 00 7

AV2 -0.05 121 80 11 AV8 +0.00 7

AV7 -0.05 10 AV6 -0.02 8

AV5 -0.05 6

AV4 -0.09 6

AV2 -0.07 121 82 10 AV8 +0.00 15 AV7 -0.02 8

AV5 -0.05 13 AV4 -0.07 12 AV3 -0.07 7

AV2 -0.05 121 90 8

AV7 -0.02 15 AV2 -0.02 10 AV1 -0.02 121 92 9

AV8 +0.00 11 AV5 +0.00 7

AV1 -0.07 121 94 12 AV8 +0.00 8

AV3 -0.12 121 96 6

AV2 -0.23 121 102 14 AV3 +0.07 5

AV4 +0.08 121 108 7 AV3 +0.07 7

AV5 +0.05 6

AV6 +0.05 121 110 7 AV4 +0.16 8

AV5 +0.05 122 61 8

AV7 +0.09 122 65 9

AV2 +0.05 8

AV3 +0.07 11 AV4 +0.05 5

AV5 +0.02 122 67 7

AV4 +0.08 8

AV6 +0.07 9

AV7 +0.09 122 73 6

AV7 -0.12 122 75 12 AV7 -0.05 11 AV5 -0.05 122 77 8

AV7 +0.18 122 79 10 AV2 -0.07 122 81 8

AV4 -0.07 8

AV3 -0.07 6

AV2 -0.05 122 83 18 AV6 +0.00 L-2019-064 Enclosure Page 44 of89 Page 28 of 32 ROW COL %TW LOCATION 10 AV1 -0.05 122 87 12 AV8 +0.00 16 AV7 +0.00 19 AV6 -0.02 16 AV4 -0.09 6

AV3 -0.05 8

AV2 -0.02 122 93 6

AV1 -0.02 122 95 8

AV2 -0.05 122 101 6 AV6 +0.05 6

AV5 +0.05 122 115 7 AV5 +0.09 9

AV7 +0.09 123 54 7

AV6 +0.12 10 AV4 +0.16 123 62 6

AV6 +0.07 123 72 13 AV3 +0.09 18 AV4 +0.03 123 74 6

AV3 +0.05 6

AV4 -0.07 6

AV5 +0.09 10 AV6 +0.09 12 AV7. +0.12 123 76 8

AV5 +0.02 7

AV4 +0.00 6

AV3 -0.05 7

AV8 +0.05 12 AV7 +0.05 7

AV6 +0.00 123 78 9

AV7 +0.00 8

AV6 -0.05 8

AV3 -0.07 123 80 16 AV8 +0.02 10 AV6 -0.02 13 AV5 +0.00 7

AV4 +0.10 8

AV3 -0.05 123 88 11 AV7 -0.02 15 AV6 -0.02 19 AV4 -0.07 12 AV2 -0.05 123 90 14 AV5 -0.03 11 AV1 -0.05 123 92 8

AV7 -0.16 16 AV5 -0.05 11 AV4 -0.02 17 AV3 -0.05 16 AV2 -0.05 8

AV1 -0.05 123 94 8

AV8 +0.00 18 AV5 -0.03 11 AV3 -0.05 9

AV2 -0.07 7

AV1 -0.05 123 96 7

AV6 -0.02 123 98 7

AV6 -0.02 5

AV2 -0.32 123 100 7 AV7 +0.07 7

AV8 +0.09 123 104 13 AV3 +0.12 11 AV4 +0.11 9

AV6 +0.09 123 106 7 AV4 +0.16 9

AV5 +0. 02 10 AV6 +0.09 7

AV7 +0.11 124 55 13 AV4 +0.21 12 AV5 +0.09 8

AV6 +0.09 9

AV7 +0.09 7

AV8 +0.14 124 63 11 AV2 +0.09

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 7

AV5 +0.05 124 69 15 AV4 +0.10 13 AV8 +0.09 10 AV1 +0.07 124 71 7

AV2 +0.07 11 AV3 +0.05 8

AV4 +0.05 10 AV5 +0.09 6

AV6 +0.09 10 AV7 +0.11 124 73 9

AV3 +0.00 9

AV5 +0.00 19 AV7 +0.09 124 75 12 AV7 +0.00 10 AV6 +0.00 8

AV5 +0.00 7

AV4 -0.07 124 77 19 AV6 -0.02 6

AV5 -0.05 7

AV4 -0.07 124 79 13 AV8 +0.00 124 87 11 AV7 +0.00 17 AV6 -0.02 7

AV3 -0.07 12 AV2 -0.05 124 91 8

AV6 -0.07 18 AV3 -0.09 12 AV7 +0.00 124 93 9

AV6 +0.17 16 AV5 -0.03 7

AV4 -0.07 7

AV3 -0.07 5

124 95 8

7 AV2 -0.09 AV7 +0.02 AV6 -0.02 13 AV4 -0.07 14 AV3 -0.05 7

AV2 -0.02 124 97 7

AV2 -0.25 124 99 9

AV6 +0.05 12 AV3 -0.02 11 AV2 -0.02 124 105 7 AV4 +0.11 124 113 7 AV1 +0.02 7

AV3 +0.02 125 50 6

AV6 +0.02 9

AV7 +0.07 10 AV8 +0.11 125 66 8

AV4 +0.18 125 68 7

AV2 +0.07 7

AV3 +0.07 7

AV4 +0.10 6

AV7 -0.47 125 72 6

AV5 +0.09 8

AV7 +0.14 125 74 6

AV2 +0.05 14 AV4 +0.13 16 AV5 +0.09 17 AV6 +0.09 125 76 125 78 125 80 125 82 125 88 125 90 5

8 7

11 16 16 6

18 9

12 14 12 18 AV7 +0.02 AV3 -0.02 AV7 -0.17 AV6 +0. 05 AV4 +0.03 AV3 +0.00 AV2 -0.05 AV3 -0.07 AV2 -0.07 AV3 -0.07 AV2 -0.05 AV8 +0.02 AV3 -0.09 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 17 AV2 -0.07 125 92 8

AV8 +0.02 6

AV7 -0.21 16 AV4 -0.09 11 AV3 -0.09 6

AV2 -0.05 125 98 10 AV4 -0.07 8

AV3 -0.07 7

AV2 -0.09 125 100 6 AV4 +0.13 8

AV5 +0. 02 125 102 7 AV2 +0.14 8

AV3 +0.12 9

AV4 +0.18 12 AV5 +0.12 12 AV6 +0.09 8

AV7 +0.11 125 104 11 AV6 +0.12 125 106 9 AV6 +0.07 8

AV5 +0.02 6

AV2 +0.05 9

AV3 +0.02 16 AV4 +0.08 125 108 7 AV6 +0.07 125 112 9 AV7 +0.07 125 120 8 AV5 +0.07 9

AV6 +0.05 126 55 7

7 AV4 +0.08 AV5 +0.07 10 AV8 +0.12 126 67 7

AV3 +0.09 11 AV4 +0.13 11 AV5 +0.14 15 AV6 +0.16 126 69 19 AV2 +0.10 126 71 126 73 126 75 126 77 126 79 126 93 126 95 126 97 126 99 13 12 16 7

6 7

5 5

9 11 7

9 10 7

9 8

13 6

12 7

7 14 7

12 7

11 13 10 9

7 11 18 10 13 18 9

5 AV4 +0.11 AV5 +0.12 AV6 +0.09 AV8 +0.11 AV4 +0.08 AV7 +0.20 AV2 +0.14 AV7 -0.12 AV8 +0.00 AV7 -0.02 AV6 -0.02 AV5 -0.03 AV4 -0.07 AV8 +0.00 AV4 -0.07 AV3 -0.07 AV7 -0.02 AV6 -0.17 AV5 -0.03 AV4 -0.09 AV4 -0.05 AV5 -0.03 AV3 -0.07 AV2 -0.02 AV6 +0.14 AV2 -0.02 AV8 +0.05 AV7 +0. 02 AV6 +0. 02 AV5 +0. 02 AV3 -0.02 AV6 +0.02 AV5 +0.02 AV4 -0.05 AV3 +0.00 AV2 -0.02 AV5 -0.03 ROW COL %TW 126 101 7 9

6 126 103 8 14 15 11 16 7

126 105 17 15 8

8 7

126 109 7 127 52 10 127 68 11 6

12 8

127 70 7

10 9

7 127 72 6

7 127 74 10 127 76 12 18 11 127 80 18 7

7 8

6 127 88 19 18 8

127 90 17 17 11 127 92 15 19 8

127 94 8

9 12 11 9

7 8

127 96 7

12 6

9 127 100 8 14 127 102 9 9

10 127 108 7 7

8 6

127 110 8 127 118 7 128 53 8

128 67 6

11 128 69 8

128 73 11 14 L-2019-064 Enclosure Page 45 of 89 Page 29 of 32 LOCATION AV3 +0.09 AV4 +0.08 AV5 +0.07 AV1 +0. 07 AV2 +0.07 AV3 +0.02 AV4 -0.02 AV5 +0.02 AV7 +0.05 AV3 +0. 02 AV4 +0.05 AV5 +0.05 AV6 +0.05 AV8 +0.12 AV4 +0.11 AV4 +0. 05 AV1 +0. 07 AV3 +0.12 AV4 +0.18 AV7 +0.05 AV3 +0.16 AV4 +0.24 AV5 +0.12 AV7 +0.14 AV6 -0.12 AV7 +0.07 AV7 +0.07 AV7 +0.07 AV6 +0.05 AV4 +0.03 AV7 +0.00 AV6 -0.02 AV5 -0.03 AV4 -0.05 AV3 -0.12 AV7 +0.00 AV4 -0.12 AV1 -0.07 AV3 -0.09 AV2 -0.07 AV1 -0.05 AV7 -0.02 AV6 -0.05 AV1 -0.07 AV7 +0.00 AV6 -0.21 AV5 -0.08 AV4 -0.05 AV3 -0.09 AV2 -0.07 AV1 -0.05 AV6 +0.00 AV3 -0.02 AV2 -0.07 AV1 -0.05 AV2 +0.07 AV4 +0.10 AV2 +0.12 AV3 +0.05 AV4 +0.11 AV2 +0. 07 AV3 +0.05 AV5 +0.05 AV6 +0.09 AV5 +0. 07 AV8 +0. 05 AV8 +0. 05 AV1 +0.05 AV7 +0.05 AV5 +0. 07 AV5 +0.05 AV7 +0.09

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVE Wear 1-19%

ROW COL %TW LOCATION 128 75 6

AV7 -0.05 7

AV6 -0. 05 128 77 8

AV7 -0.02 128 79 8

AV8 +0.00 16 AV7 -0.05 8

AV5 -0.03 128 87 14 AV8 +0.02 16 AV7 +0.00 17 AV6 +0.00 128 93 19 AV5 +0.00 8

AV4 -0.05 14 AV3 -0.05 9

AV2 -0.05 128 95 9

AV8 +0.02 14 AV5 -0.05 8

AV4 -0.09 6

AV3 -0.07 9

AV2 -0.07 128 97 7

AV6 -0.02 10 AV4 -0.07 128 99 12 AV8 +0.00 11 AV5 -0.08 15 AV3 -0.09 16 AV2 -0.07 128 101 6 AV3 +0.00 10 AV4 +0.05 13 AV5 +0. 02 10 AV6 +0.07 128 103 8 AV2 +0.05 6

AV4 +0.05 128 107 7 AV2 +0.07 6

AV3 +0.09 7

AV4 +0.16 9

AV5 +0.05 15 AV6 +0.05 10 AV7 +0.07 128 109 7 AV4 +0.16 8

AV5 +0.02 128 117 8 AV2 +0.00 14 AV4 +0.11 13 AV5 +0.07 129 66 9

AV3 +0.12 10 AV5 +0.12 129 68 7

AV2 +0.07 7

AV7 -0.07 129 70 7

AV7 -0.12 129 72 7

AV7 +0.21 129 74 8

AV2 +0.12 14 AV4 +0.08 16 AV5 +0.09 12 AV6 +0.09 7

AV7 +0.21 129 78 17 AV7 +0.02 19 AV5 +0.02 5

AV2 -0.05 8

AV8 +0.02 129 80 17 AV3 -0.07 19 AV2 -0.04 6

AV1 -0.05 129 86 7

AV8 +0.05 8

AV5 -0.05 129 88 12 AV8 +0.02 19 AV6 -0.05 12 AV4 -0.07 8

AV3 -0.07 6

AV2 -0.07 8

AV1 -0.02 129 94 6

AV7 -0.02 7

AV5 -0.11 10 AV3 -0.12 10 AV2 -0.09 129 96 8

AV5 -0.08 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 9

AV4 -0.07 6

AV2 -0.09 7

AV1 -0.05 129 98 9

AV7 -0.05 18 AV5 -0.05 9

AV4 -0.07 9

AV3 -0.02 8

AV2 -0.02 129 100 10 AV6 +0.12 129 102 7 AV4 +0.05 7

AV5 +0.07 6

AV6 +0.07 129 104 7 AV1 +0.09 7

AV2 +0.10 7

AV3 +0.12 7

AV4 +0.11 10 AV5 +0.02 8

AV8 +0.09 129 106 8 AV2 +0.12 7

AV3 +0. 07 10 AV4 +0.13 15 AV5 +0.05 7

AV6 +0.05 7

AV7 +0.09 129 108 6 AV5 +0.05 7

AV6 +0.05 130 69 10 AV5 +0.05 7

AV6 +0.07 130 71 7

AV3 +0.09 8

AV4 +0.05 6

AV5 +0.05 14 AV6 +0.09 130 73 7

AV6 -0.12 11 AV7 -0.14 130 75 10 AV7 +0.02 8

AV5 -0.08 18 AV4 -0.09 10 AV3 -0.09 130 79 12 AV8 +0.05 8

AV4 -0.02 11 AV3 -0.07 130 93 13 AV8 +0.05 15 AV6 +0.07 12 AV5 +0.07 19 AV4 +0.05 130 95 13 AV8 +0.02 8

AV5 +0.02 15 AV4 +0.00 14 AV3 -0.02 8

AV2 -0.05 6

AV1 +0.00 130 97 19 AV5 +0.02 11 AV4 +0.00 8

AV1 -0.05 130 101 10 AV5 +0.05 7

AV6 +0.09 12 AV3 +0.09 15 AV4 +0.03 8

AV2 +0.05 130 113 9 AV8 -0.05 131 68 6

AV2 +0.15 6

AV3 +0.12 131 70 7

AV5 +0.07 13 AV7 -0.09 131 74 11 AV2 +0.09 6

AV3 +0.12 15 AV8 +0.14 131 76 7

AV6 +0.02 13 AV5 +0.00 11 AV4 +0.00 131 78 7

AV7 +0.05 16 AV3 -0.07 L-2019-064 Enclosure Page 46 of 89 Page 30 of 32 ROW COL %TW LOCATION 131 82 16 AV8 +0.02 13 AV5 -0.08 19 AV4 -0.07 131 88 8

AV8 -0.02 10 AV6 +0.00 16 AV3 -0.12 131 92 16 AV4 -0.07 131 94 13 AV8 +0.02 8

AV5 -0.05 15 AV2 -0.07 8

AV1 -0.05 131 96 7

AV6 -0.02 8

AV5 -0.05 8

AV4 -0.07 6

AV2 -0.11 131 98 8

AV7 -0.02 6

AV6 +0.00 7

AV4 -0.05 4

AV2 -0.27 131 100 7 AV5 +0.05 7

AV6 +0. 07 131 102 7 AV3 +0.12 7

AV5 +0.07 7

AV6 +0.09 14 AV7 +0.07 132 69 13 AV4 +0.18 6

AV5 +0.28 16 AV7 +0.14 132 71 7

AV3 +0.16 9

AV5 +0.05 16 AV7 +0.07 15 AV8 +0.12 132 73 8

AV6 -0.14 13 AV7 +0.11 10 AV8 +0.12 132 75 11 AV8 -0.02 15 AV7 -0.02 10 AV6 -0.02 132 77 7

AV8 +0.02 5

AV7 +0.00 13 AV6 +0.00 7

AV5 -0.03 7

AV3 -0.09 132 79 8

AV8 +0.05 15 AV4 -0.12 11 AV3 -0.09 132 81 19 AV8 +0.02 18 AV7 +0.00 12 AV5 -0.08 132 85 9

AV6 -0.07 132 87 15 AV7 +0.00 19 AV6 -0.02 14 AV5 -0.05 7

AV4 -0.07 6

AV3 -0.05 6

AV2 -0.09 132 93 13 AV5 -0.05 15 AV4 -0.05 18 AV3 -0.09 14 AV2 -0.07 132 95 11 AV7 -0.05 6

AV5 -0.05 7

AV4 -0.02 6

AV2 -0.05 132 97 11 AV7 -0.02 8

AV6 +0.00 10 AV5 -0.10 14 AV4 -0.09 13 AV3 -0.07 8

AV2 -0.07 132 99 11 AV4 +0.03 7

AV2 -0.25

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 132 101 8 AV4 +0.05 133 68 11 AV4 +0.00 9

AV5 -0.03 19 AV7 +0.05 19 AV8 +0.09 8

AV1 +0.00 17 AV3 +0.00 133 70 7

AV6 -0.02 14 AV8 +0.09 133 72 19 AV3 +0.00 17 AV4 -0.02 16 AV5 -0.03 16 AV6 +0.00 133 74 6

AV2 +0.12 12 AV4 +0. 05 8

AV6 -0.14 14 AV8 +0.14 133 76 8

AV7 +0.00 15 AV5 +0.00 19 AV4 -0.05 6

AV3 -0.07 5

AV2 -0.04 6

AV1 -0.07 133 78 9

7 AV8 +0.05 AV7 +0.05 8

AV6 +0.00 13 AV5 +0. 00 6

AV4 -0.05 7

AV3 -0.05 133 86 17 AV4 -0.07 9

AV1 -0.07 133 88 7

AV8 -0.02 16 AV7 -0.02 7

AV5 -0.10 8

AV4 -0.16 7

AV3 -0.16 7

AV2 -0.09 133 92 14 AV6 +0.00 10 AV5 -0.05 6

AV1 -0.12 11 AV8 +0.02 133 94 9

AV7 +0.02 14 AV6 -0.02 11 AV5 -0.05 18 AV4 -0.07 13 AV3 -0.09 133 96 7

AV5 +0.05 5

AV1 -0.07 133 102 6 AV7 +0.09 134 65 7

134 67 7

AV8 +0.07 AV2 -0.02 18 AV4 +0.00 7

AV6 +0.16 9

AV7 +0.27 14 AV5 +0.12 134 69 11 AV6 +0.07 10 AV7 +0.27 8

AV8 +0.14 134 71 9

AV7 -0.12 134 73 14 AV2 +0.05 9

AV3 +0.05 18 AV5 -0.05 134 75 6

AV7 -0.21 14 AV6 -0.05 10 AV5 -0.13 7

AV4 -0.23 134 77 7

AV7 -0.09 8

AV6 -0.05 134 79 11 AV8 -0.02 9

AV7 +0.00 134 83 8

AV8 +0.05 13 AV4 -0.09 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 7

AV3 -0.07 134 85 10 AV7 +0.02 12 AV6 +0.00 9

AV5 +0.00 7

AV4 -0.07 13 AV3 -0.12 134 87 18 AV7 +0.02 10 AV4 -0.05 15 AV3 -0.07 11 AV2 -0.11 134 89 7

AV8 +0.02 15 AV7 +0.05 14 AV6 +0.02 6

AV5 +0.00 134 93 6

AV8 -0.05 6

AV6 +0.18 16 AV5 +0.00 11 AV4 -0.05 7

AV3 -0.07 9

AV2 -0.11 134 95 6

AV6 +0.02 10 AV4 -0.05 134 97 7

AV6 +0.00 13 AV5 -0.08 13 AV2 -0.09 13 AV1 -0.09 134 103 11 AV4 -0.05 12 AV5 +0.12 10 AV6 +0.16 8

AV7 +0.18 135 70 7

8 135 72 7

6 AV2 +0.05 AV7 +0. 32 AV4 +0.13 AV5 +0.17 8

AV6 +0.12 10 AV7 +0.27 135 74 6

AV1 +0.05 5

AV2 +0.21 8

AV5 +0.14 6

AV6 -0.12 7

AV7 +0.27 5

AV8 +0.29 135 78 10 AV7 +0.02 19 AV6 +0.00 135 80 10 AV7 -0.02 6

AV2 -0.07 135 90 17 AV6 -0.05 18 AV3 -0.09 9

AV1 -0.12 135 92 7

AV1 -0.09 135 94 12 AV8 +0.05 7

AV3 -0.05 9

AV6 -0.16 8

AV4 -0.02 7

9 AV2 -0.09 AV1 -0.07 135 96 19 AV8 +0.00 10 AV7 -0.05 12 AV6 -0.05 7

AV2 -0.07 136 71 9

AV5 +0.05 10 AV8 +0.11 136 73 9

AV2 +0.07 6

AV3 +0.05 14 AV4 +0.05 10 AV5 +0.05 6

AV6 -0.16 14 AV7 -0.09 7

AV8 +0.14 136 75 6

AV8 -0.16 9

AV4 -0.07 10 AV3 -0.12 ROW COL %TW 7

9 136 77 15 10 19 15 8

13 6 7 9 7

10 136 81 14 11 16 9

7 5

136 83 10 11 136 85 15 13 11 8

136 91 14 12 18 16 7

136 93 7

16 11 136 95 9

6 137 74 7

15 8

16 137 76 7

6 8

6 9

7 6

137 78 9

137 84 13 19 137 86 10 11 137 92 16 11 6

137 94 10 11 7

L-2019-064 Enclosure Page 47 of89 Page 31 of 32 LOCATION AV2 -0.11 AV1 -0.09 AV7 +0.00 AV6 -0.05 AV5 -0.08 AV3 -0.12 AV2 -0.14 AV8 -0.09 AV7 -0.05 AV8 +0.05 AV7 +0.02 AV6 +0.02 AV5 +0.02 AV3 -0.07 AV2 -0.02 AV8 +0.02 AV2 -0.11 AV7 +0.02 AV6 +0. 02 AV4 -0.07 AV3 -0.11 AV8 +0. 05 AV6 +0. 02 AV4 -0.05 AV2 -0.09 AV1 -0.05 AV8 -0.02 AV2 -0.09 AV1 -0.09 AV6 -0.02 AV2 -0.09 AV4 +0.00 AV5 +0.05 AV6 +0.09 AV7 +0.27 AV8 +0.14 AV7 +0.05 AV6 -0.07 AV5 -0.08 AV4 -0.07 AV3 -0.09 AV2 -0.13 AV1 -0.12 AV7 -0.24 AV8 +0. 02 AV7 +0.02 AV8 +0.02 AV7 -0.02 AV7 -0.05 AV6 -0.05 AV3 -0.30 AV8 +0. 02 AV7 +0. 02 AV6 -0.21 6

AV5 -0.08 137 96 10 AV6 +0.02 138 73 12 AV6 +0.23 9

AV7 +0.25 138 75 10 AV8 -0.05 8

AV7 +0.18 6

AV6 +0. 00 138 77 12 AV7 +0.20 11 AV5 -0.08 6

AV4 -0.11 7

AV3 -0.12 138 79 7

AV8 -0.02 9

AV7 +0.05 15 AV6 -0.02 8

AV4 -0.07 7

AV3 -0.07 138 81 6

AV8 -0.02 138 83 9

AV8 +0.05

Framatome Inc.

Customer: FPL Plant:

09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 12 AV5 -0.08 7

AV7 +0. 00 138 85 9

AV7 +0.02 13 AV6 -0.02 6

AV4 -0.12 6

AV8 +0.02 138 87 8

AV7 +0.00 138 89 10 AV8 +0.00 138 93 4

AV8 -0.17 11 AV7 +0.05 18 AV6 +0.05 6

AV5 +0.05 139 78 10 AV7 +0.18 18 AV6 +0.02 12 AV3 -0.07 7

AV2 -0.07 6

AV1 -0.23 139 86 9

AV8 +0.05 12 AV7 +0.02 6

AV6 -0.02 139 92 4

AV8 +0.07 12 AV6 +0.05 8

AV5 +0.05 14 AV4 -0.05 6

AV3 -0.09 12 AV2 -0.25 Total Tubes 2638 Total Records: 6722 Appendix F: Wear <40% at AVBs St Lucie Unit: 2 Component: S/G A ROW COL %TW LOCATION L-2019-064 Enclosure Page 48 of 89 Page 32 of 32 ROW COL %TW LOCATION

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 44 163 23 AV7 -0.24 46 7

20 AV6 +0.25 51 52 53 54 55 56 56 56 57 58 59 60 60 162 25 161 22 162 21 9

21 160 22 9

22 11 21 161 30 158 21 11 23 160 25 153 22 157 26 AV6 +0.16 AV6 -0.34 AV6 +0.18 AV3 -0.18 AV3 +0. 25 AV6 +0.23 AV6 -0.24 AV6 -0.39 AV6 -0.24 AV7 +0.02 AV6 -0.35 AV6 -0.10 AV7 -0.05 25 AV6 -0.10 61 116 24 AV6 +0.05 61 156 22 AV8 -0.21 28 AV6 -0.10 62 11 26 AV6 -0.21 21 AV7 +0.28 62 62 63 63 63 64 64 64 65 65 65 65 65 65 105 24 107 25 12 34 23 114 22 146 22 13 22 29 20 155 26 12 23 108 21 110 21 134 20 152 20 24 154 21 AV6 +0.07 AV6 +0. 07 AV3 +0.18 AV6 -0.20 AV6 +0.02 AV6 +0. 00 AV6 +0.00 AV6 +0.02 AV3 -0.05 AV6 -0.18 AV6 +0. 05 AV6 +0.00 AV6 +0. 05 AV7 -0.07 AV6 -0.10 AV3 +0.15 24 AV6 +0.02 66 13 28 AV6 -0.03 66 15 25 AV3 +0.20 26 AV6 +0.00 66 99 26 AV6 +0.07 66 103 28 AV6 +0.05 32 AV7 +0.09 66 105 26 AV6 +0.05 66 153 24 AV8 -0.07 21 AV7 -0.07 24 AV3 -0.05 67 20 20 AV6 +0.02 67 52 22 AV6 +0.07 67 74 26 AV6 +0.05 20 AV7 +0.02 67 76 20 AV3 +0.12 21 AV6 +0.05 67 102 25 AV3 +0.13 23 AV6 +0.05 67 104 25 AV3 +0.05 29 AV6 +0.09 67 132 20 AV6 +0.02 67 146 29 AV3 +0.13 67 148 25 AV3 +0.10 23 AV6 +0.02 67 154 33 AV3 +0.13 31 AV6 +0.02 68 67 20 AV6 +0.07 68 75 20 AV2 +0.12 23 AV3 +0.20 35 AV6 +0.07 22 AV7 +0.02 68 89 20 AV3 -0.09 68 101 25 AV6 +0.07 68 111 33 AV6 +0.05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 22 AV7 +0.04 68 115 29 AV6 +0.07 31 AV7 +0.11 68 147 24 AV6 +0.02 68 149 20 AV6 +0.00 68 155 25 AV8 -0.21 36 AV7 -0.07 29 AV6 -0.23 25 AV3 -0.02 68 157 31 AV6 -0.02 21 AV7 +0.04 20 AVS +0.23 69 88 25 AV6 -0.04 69 100 21 AV6 +0.07 69 104 31 AV6 +0.07 20 AV7 +0.05 69 106 20 AV6 +0.05 69 108 23 AV3 +0.06 32 AV6 +0.05 23 AV7 +0.02 69 154 24 AV6 +0.05 70 101 20 AV3 +0.06 34 AV6 +0.05 21 AV7 +0.02 70 103 21 AV7 +0.00 70 105 21 AV3 +0.04 70 109 29 AV6 +0.05 28 AV7 +0.05 71 76 23 AV6 +0.07 27 AV7 +0.05 71 98 22 AV5 +0.04 71 102 24 AV3 +0.02 26 AV4 +0.30 71 104 24 AV6 +0.07 71 108 21 AV3 +0.08 20 AV4 +0.38 72 67 23 AV2 +0.12 26 AV3 +0.11 23 AV5 +0.06 21 AV6 +0.07 72 71 22 AV6 +0.02 22 AV7 +0. 02 72 75 29 AV6 +0.05 24 AV7 +0. 02 72 79 28 AV6 +0.07 20 AV7 +0.05 28 AV8 +0.07 72 91 22 AV6 +0.00 22 AV3 -0.02 72 101 23 AV5 +0.06 30 AV6 +0. 05 72 103 24 AV3 +0.11 32 AV5 +0.13 28 AV6 +0.12 23 AV7 +0.09 72 105 23 AV3 +0.04 72 107 29 AV6 +0.07 72 109 28 AV5 +0.09 24 AV6 +0.05 73 18 27 AV4 +0.37 73 74 35 AV4 +0.03 28 AV5 +0.09 32 AV6 +0. 05 28 AV7 +0.02 73 76 22 AV3 +0.13 26 AV4 +0.12 32 AV5 +0.09 25 AV6 +0. 07 29 AV7 +0.05 73 88 21 AV7 -0.05 22 AV6 -0.07 25 AV5 +0. 00 L-2019-064 Enclosure Page 49 of 89 Page 1 of 11 ROW COL %TW LOCATION 22 AV3 -0.05 73 94 22 AV5 +0.07 21 AV6 +0.02 73 96 21 AV4 +0.00 22 AV5 +0.06 21 AV6 +0. 05 73 98 24 AV5 +0.06 73 102 33 AV4 +0.07 37 AV5 +0.07 30 AV6 +0.07 22 AV7 +0.00 73 104 32 AV5 +0.07 32 AV6 +0.05 73 106 25 AV3 +0.04 73 108 21 AV3 +0.06 73 110 21 AV6 +0.02 20 AV7 +0.05 73 116 26 AV5 +0.11 74 67 27 AV6 +0.02 24 AV7 +0.02 74 71 26 AV4 +0.03 20 AV5 +0.04 36 AV6 +0.05 37 AV7 +0.07 27 AV8 +0.07 74 73 26 AV3 +0.07 29 AV4 +0.03 29 AV5 +0.07 25 AV6 +0.05 23 AV7 -0.02 74 75 20 AV6 +0.07 74 77 24 AV6 +0.00 74 81 23 AV3 +0.07 23 AV4 -0.02 20 AV6 +0.02 74 87 24 AV5 +0.00 20 AV3 -0.05 74 89 20 AV7 -0.02 28 AV6 -0.02 23 AV5 +0.02 21 AV4 -0.07 30 AV3 -0.05 74 93 22 AV5 +0.09 74 95 24 AV6 +0.05 22 AV7 +0.05 74 97 25 AV3 +0.14 21 AV4 +0.00 28 AV5 +0.12 23 AV6 +0.07 74 101 22 AV4 +0.03 24 AV5 +0.07 28 AV6 +0.07 74 103 24 AV3 +0.14 74 109 39 AV5 +0.09 34 AV6 +0.07 34 AV7 +0.02 23 AV8 +0.05 74 111 26 AV5 +0.09 24 AV6 +0.07 74 145 25 AV2 +0.02 21 AV3 +0.09 75 56 21 AV4 +0.23 75 66 22 AV5 +0.04 75 72 21 AV4 +0.03 29 AV5 +0.07 27 AV6 +0. 07 75 76 22 AV4 +0.00 25 AV5 +0.05 75 80 20 AV5 +0.07 75 86 24 AV3 -0.07 75 92 20 AV6 -0.05 75 94 29 AV4 +0.03

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVE Wear 20-39%

ROW COL %TW LOCATION 25 AV5 +0.05 23 AV6 +0.02 75 96 30 AV4 +0.00 29 AV5 +0.05 31 AV6 +0.05 75 98 23 AV4 +0.00 75 75 75 20 100 22 24 102 21 37 31 104 20 AV7 +0. 02 AV6 +0.05 AV7 +0.02 AV3 +0.05 AV4 +0.03 AV6 +0. 07 AV2 +0. 05 25 AV3 +0.02 36 AV5 +0.05 36 AV6 +0.05 75 106 24 AV4 +0.00 23 AV5 +0.07 22 AV6 +0.05 75 108 26 AV3 +0.07 28 AV4 +0.03 75 116 22 AV5 -0.09 76 59 21 AV4 +0.00 25 AV5 +0.05 26 AV6 +0.05 76 65 20 AV5 +0.05 76 71 20 AV3 +0.16 24 AV4 +0.00 76 75 22 AV3 +0.09 23 AV4 +0.03 37 AV5 +0.07 36 AV6 +0.02 25 AV7 +0.02 76 81 25 AV3 +0.09 30 AV4 +0.00 76 76 76 76 76 76 76 76 76 76 76 32 31 25 87 23 27 22 25 89 21 95 21 97 22 25 38 29 99 24 20 22 32 103 21 24 24 24 105 27 35 31 20 107 21 28 20 27 109 20 31 26 111 24 26 29 28 115 20 AV5 +0.02 AV6 +0. 05 AV7 +0.02 AV6 +0. 00 AV5 +0. 02 AV4 -0.02 AV3 -0.05 AV3 -0.09 AV3 +0.07 AV3 +0.07 AV4 +0.09 AV5 +0.07 AV6 +0.07 AV6 +0.04 AV7 +0.02 AV2 +0.10 AV5 +0.10 AV2 +0.14 AV4 +0.00 AV5 +0.12 AV7 +0.00 AV3 +0. 05 AV4 +0.00 AV5 +0. 09 AV7 +0. 05 AV3 +0.07 AV4 +0.03 AV5 +0.07 AV6 +0.07 AV3 +0.12 AV5 +0.09 AV6 +0.07 AV7 +0.05 AV4 +0.09 AV5 +0.09 AV6 +0.05 AV4 +0.00 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 77 18 22 AV4 +0.25 77 72 20 AV4 +0.00 30 AV5 +0.02 28 AV6 +0.05 77 74 30 AV4 -0.02 30 AV5 +0.05 27 AV6 +0.05 77 77 76 20 AV3 +0.00 34 AV4 +0.03 34 AV5 +0.02 23 AV6 +0.00 78 24 AV4 +0.03 21 AV5 +0.05 77 80 31 AV3 +0.14 28 AV4 +0.03 35 AV5 +0.05 31 AV6 +0.05 34 AV7 +0.05 77 88 21 AV7 -0.02 77 90 27 AV5 +0.00 24 AV4 -0.05 20 AV3 -0.02 77 92 30 AV3 +0.05 31 AV4 +0.03 34 AV5 +0.02 32 AV6 +0.05 27 AV7 +0.02 77 94 20 AV4 +0.03 27 AV5 +0.05 29 AV6 +0.05 77 96 22 AV6 +0.05 77 98 22 AV2 +0.05 24 AV3 +0.07 77 77 77 77 77 77 77 77 78 78 78 38 AV4 +0.03 21 AV6 +0.07 100 23 AV3 +0.05 25 AV6 +0.09 22 AV7 +0.05 102 28 AV4 +0.00 31 AV5 +0.07 31 AV6 +0.07 104 22 AV3 +0.12 34 AV5 +0.07 36 AV6 +0.07 106 20 AV3 +0.07 36 AV4 +0.03 32 AV5 +0.07 29 AV6 +0.07 108 20 AV3 +0.12 28 AV4 +0.00 26 AV5 +0.07 20 AV6 +0.05 112 25 AV4 +0.03 23 AV5 +0.05 26 AV6 +0.05 26 AV7 +0.05 114 25 AV4 +0.03 33 AV5 +0.05 116 26 AV4 +0.06 37 AV5 +0.07 23 AV6 +0.05 20 AV7 +0.04 22 AV3 +0.11 69 24 AV3 +0.07 32 AV4 +0.03 29 AV5 +0.05 25 AV6 +0.07 73 22 AV3 +0.09 26 AV5 +0.02 28 AV6 +0.05 24 AV7 +0.09 75 23 AV3 +0.05 L-2019-064 Enclosure Page 50 of 89 Page 2 of 11 ROW COL %TW LOCATION 31 AV5 +0. 02 30 AV6 +0.07 32 AV7 +0. 02 20 AV8 +0.02 78 77 22 AV4 +0.03 29 AV5 +0.05 27 AV6 +0.05 78 79 78 83 78 89 21 AV4 +0.05 29 AV6 +0.07 20 AV5 +0.04 20 AV6 +0.05 20 AV7 -0.05 32 AV6 -0.02 35 AV5 +0.00 30 AV4 -0.02 29 AV3 -0.05 78 95 25 AV3 +0.07 24 AV4 +0.06 78 97 24 AV3 +0.05 22 AV4 +0.05 37 AV5 +0.07 32 AV6 +0.05 78 99 21 AV2 +0.07 24 AV3 +0.05 22 AV4 +0.06 38 AV5 +0.07 38 AV6 +0.09 22 AV7 +0.07 78 101 32 AV4 +0.05 34 AV5 +0.07 33 AV6 +0.09 78 107 26 AV6 +0.07 78 111 23 AV4 +0.11 24 AV5 +0.07 78 79 79 79 79 79 79 79 79 79 79 79 79 79 79 79 26 AV6 +0.05 113 27 62 22 68 20 70 21 72 30 33 20 74 21 30 36 29 76 26 35 30 30 78 22 23 25 80 27 26 20 82 23 21 86 32 90 20 92 31 27 26 31 94 22 23 22 25 96 30 102 30 37 34 AV6 +0.02 AV5 +0. 05 AV7 +0.05 AV6 +0.09 AV5 +0.04 AV6 +0.05 AV7 +0. 02 AV4 +0.03 AV5 +0.05 AV6 +0.05 AV7 +0.02 AV4 +0.08 AV5 +0.07 AV6 +0.05 AV7 +0.05 AV4 +0. 03 AV6 +0.05 AV7 +0.05 AV5 +0.02 AV6 +0.05 AV7 +0.02 AV4 +0.00 AV5 +0.05 AV3 -0.02 AV6 +0.00 AV3 +0.02 AV4 +0.06 AV5 +0.05 AV6 +0. 07 AV3 +0.05 AV4 +0.00 AV5 +0.02 AV7 +0.00 AV6 +0.05 AV3 +0.12 AV4 +0. 03 AV5 +0.07

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 27 AV6 +0.09 79 104 22 AV2 +0.05 25 AV3 +0. 07 24 AV5 +0.07 79 106 20 AV3 +0.05 34 AV4 +0.05 32 AV5 +0.05 27 AV6 +0.07 79 108 22 AV3 +0.07 29 AV4 +0.03 21 AV6 +0.05 27 AV7 +0.07 80 67 20 AV5 +0.02 20 AV6 +0.05 80 69 22 AV3 +0.18 30 AV4 +0.05 28 AV5 +0.07 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 81 81 81 71 73 75 77 83 85 87 89 26 26 20 39 30 33 21 23 26 20 29 29 33 27 30 23 27 26 26 24 20 20 20 26 29 31 AV6 +0.07 AV7 +0.05 AV3 +0. 05 AV4 +0. 00 AV6 +0. 05 AV7 +0.02 AV4 +0.05 AV5 +0.07 AV6 +0. 07 AV4 +0. 03 AV5 +0.05 AV6 +0.02 AV7 +0. 02 AV3 +0.09 AV4 +0.00 AV5 +0.05 AV6 +0. 02 AV5 +0. 05 AV6 +0. 05 AV7 +0.05 AV6 +0.07 AV6 -0.02 AV5 -0.03 AV4 -0.07 AV6 -0.02 AV5 -0.03 29 AV4 -0.05 28 AV3 -0.07 91 21 AV6 -0.02 93 30 AV4 +0.03 33 AV5 +0.07 95 26 AV3 +0.07 31 AV4 +0.03 32 AV5 +0.02 99 29 AV5 +0.02 30 AV6 +0.07 25 AV7 +0.00 101 20 AV2 +0.05 26 AV3 +0.00 36 AV4 +0.03 37 AV5 +0.05 31 AV6 +0.09 105 23 AV5 +0.10 107 28 AV6 +0.05 111 20 AV5 +0.02 29 AV4 +0.05 115 25 AV6 +0.05 117 21 AV5 +0.26 21 AV7 +0.02 66 20 AV5 +0.07 20 AV6 +0.09 70 23 AV3 +0.09 20 AV5 +0. 04 26 AV6 +0.05 72 20 AV2 +0.07 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 25 AV3 +0.12 29 AV4 +0.05 39 AV5 +0.11 28 AV7 +0.05 81 74 21 AV4 +0.11 23 AV6 +0.05 81 76 33 AV4 +0.03 32 AV5 +0.07 81 78 36 AV4 +0.05 33 AV5 +0.07 26 AV6 +0.07 81 82 24 AV3 +0.07 33 AV4 +0.05 30 AV5 +0.07 30 AV6 +0.05 29 AV7 +0.05 81 90 21 AV3 -0.02 81 81 81 81 81 81 81 81 81 82 82 82 82 82 82 82 82 82 82 82 92 24 21 23 94 24 25 28 96 24 21 35 100 23 36 28 30 102 32 35 106 21 108 23 110 27 114 20 67 33 22 27 29 27 28 69 25 AV3 +0. 07 AV5 +0.05 AV6 +0.07 AV3 +0.10 AV4 +0.03 AV5 +0.07 AV4 +0.05 AV5 +0.07 AV6 +0.07 AV3 +0.07 AV4 +0.05 AV5 +0.07 AV6 +0.07 AV4 +0. 05 AV6 +0.07 AV4 +0.03 AV3 +0.07 AV5 +0.07 AV5 +0.07 AV6 +0.05 AV7 +0. 02 AV2 +0.07 AV3 +0.07 AV4 +0.03 AV5 +0. 05 AV4 +0.03 31 AV5 +0.02 25 AV6 +0.05 25 AV7 +0.05 77 22 AV5 +0.07 37 AV6 +0. 05 33 AV7 +0.00 79 31 AV3 +0.07 27 AV4 +0.05 28 AV5 +0.07 31 AV6 +0. 07 81 22 AV5 +0.02 25 AV7 +0.02 83 26 AV4 +0.00 31 AV5 +0.05 28 AV6 +0.05 27 AV7 +0.02 85 28 AV4 +0.00 35 AV5 +0.02 36 AV6 +0.07 22 AV7 +0.05 87 23 AV4 -0.05 89 25 AV5 -0.03 31 AV4 -0.05 29 AV3 -0.05 91 24 AV6 -0.02 25 AV5 -0.08 24 AV4 -0.05 93 30 AV4 +0.03 31 AV5 +0.05 L-2019-064 Enclosure Page 51 of 89 Page 3 of 11 ROW COL %TW LOCATION 37 AV6 +0.07 31 AV7 +0. 05 82 95 21 AV2 +0.05 29 AV3 +0.04 37 AV4 +0.03 35 AV5 +0. 02 23 AV6 +0.05 27 AV7 +0.07 82 97 30 AV5 +0.07 24 AV6 +0.07 82 99 22 AV2 +0.08 31 AV4 +0.03 37 AV5 +0.05 37 AV6 +0. 07 29 AV7 +0.02 82 107 31 AV6 +0.07 27 AV7 +0.05 82 82 82 83 83 83 83 83 83 83 83 83 83 83 83 83 83 109 20 115 20 117 27 25 64 21 28 68 20 29 24 72 35 31 33 74 20 20 30 31 23 76 32 31 38 36 23 78 36 30 25 22 80 21 22 30 27 84 20 22 86 25 27 24 88 27 26 31 26 92 33 31 33 35 30 94 20 22 39 39 37 96 37 34 31 31 98 37 33 AV6 +0.07 AV6 +0. 07 AV5 +0.07 AV6 +0. 07 AV5 +0.07 AV6 +0.05 AV5 +0.09 AV6 +0.07 AV7 +0.07 AV5 +0. 02 AV6 +0. 05 AV7 +0. 02 AV3 +0.05 AV4 +0.03 AV5 +0.05 AV6 +0.05 AV7 +0.05 AV3 +0. 05 AV4 +0.08 AV5 +0.07 AV6 +0.07 AV7 +0.02 AV4 +0. 03 AV5 +0.05 AV6 +0.07 AV7 +0.05 AV4 +0.08 AV5 +0.05 AV6 +0.02 AV7 +0.05 AV3 +0.05 AV5 +0.05 AV7 -0.05 AV6 +0.00 AV5 -0.03 AV7 -0.02 AV6 -0.02 AV5 +0.00 AV4 -0.05 AV3 +0.09 AV4 +0.05 AV5 +0.05 AV6 +0.05 AV7 +0.04 AV3 +0.09 AV4 +0.08 AV5 +0.09 AV6 +0.09 AV7 +0.05 AV3 +0.09 AV4 +0.08 AV5 +0.07 AV6 +0.05 AV3 +0.07 AV5 +0.07

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 24 AV6 +0.07 83 100 23 AV4 +0.08 32 AV5 +0.07 30 AV6 +0.09 83 102 25 AV2 +0.12 35 AV3 +0.05 37 AV4 +0.08 38 AV5 +0.09 25 AV7 +0.02 83 104 24 AV2 +0.12 20 AV3 +0.12 27 AV4 +0.11 39 AV5 +0.05 35 AV6 +0.09 83 83 83 83 84 84 84 84 84 106 24 AV4 +0.08 23 AV5 +0.05 28 AV6 +0.05 108 22 AV3 +0.14 23 AV4 +0.11 26 AV5 +0.07 31 AV6 +0.07 110 24 AV5 +0.09 112 20 AV4 +0.08 67 25 AV4 +0.11 23 AV5 +0.07 20 AV6 +0.09 69 29 AV4 +0.11 35 AV5 +0.09 33 AV6 +0.09 32 AV7 +0.07 71 26 AV3 +0.05 29 AV4 +0.05 26 AV5 +0.02 73 75 23 29 26 33 23 30 31 22 AV3 +0.14 AV4 +0.08 AV5 +0.05 AV6 +0. 07 AV7 +0.07 AV3 +0.07 AV4 +0.00 AV5 +0.02 84 79 24 AV3 +0.00 29 AV5 +0.02 32 AV6 +0.05 84 84 84 84 84 84 84 84 81 34 21 83 23 26 85 24 31 32 34 24 87 31 33 36 30 89 29 33 36 35 91 22 28 27 95 24 27 27 21 101 33 37 39 34 AV5 +0.05 AV6 +0.07 AV5 +0.07 AV6 +0.07 AV3 +0.12 AV4 +0.08 AV5 +0.05 AV6 +0.10 AV7 +0.05 AV6 -0.02 AV5 -0.03 AV4 -0.05 AV3 -0.07 AV6 -0.05 AV5 -0.08 AV4 -0.09 AV3 -0.12 AV6 -0.02 AV5 -0.08 AV4 -0.05 AV2 +0.07 AV4 +0.05 AV5 +0.07 AV6 +0.09 AV4 +0.08 AV5 +0.07 AV6 +0.09 AV7 +0.05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 84 105 37 AV3 +0.05 38 AV4 +0.08 38 AV5 +0.09 28 AV6 +0.07 84 107 21 AV3 +0.12 21 AV4 +0.09 27 AV6 +0.07 27 AV7 +0.07 84 109 21 AV2 +0.07 29 AV3 +0.05 84 113 20 AV3 +0.07 84 84 85 85 85 85 85 85 20 AV4 +0.06 23 AV5 +0.07 115 20 AV4 +0.09 29 AV5 +0.07 25 AV6 +0.05 117 22 AV4 +0.09 26 AV5 +0.09 22 AV6 +0. 05 68 22 AV2 +0.12 21 AV6 +0.00 25 AV7 +0.02 70 28 AV4 +0.05 26 AV5 +0.05 27 AV6 +0. 05 20 AV7 +0.02 21 AV3 +0.09 78 36 AV4 +0.05 27 AV5 +0.07 23 AV6 +0.07 22 AV7 +0. 05 80 28 AV6 +0.07 82 23 AV4 +0.10 24 AV5 +0.07 25 AV6 +0. 07 28 AV7 +0.05 86 36 AV7 -0.07 39 AV6 -0.07 34 AV5 -0.11 28 AV4 -0.07 29 AV3 -0.07 85 88 25 AV5 -0.03 23 AV4 -0.05 85 90 23 AV5 +0.02 85 85 85 85 85 86 86 86 23 92 29 34 30 37 94 32 36 22 100 21 33 32 34 21 106 29 32 32 108 29 23 22 69 27 32 34 23 71 22 31 32 26 75 29 AV3 -0.05 AV4 +0. 00 AV5 +0.00 AV6 +0. 05 AV7 +0. 02 AV4 +0.05 AV5 +0. 05 AV6 +0.07 AV2 +0.10 AV3 +0.09 AV4 +0.05 AV5 +0.05 AV6 +0.05 AV2 +0.07 AV3 +0.02 AV4 +0. 05 AV3 +0. 02 AV4 +0. 05 AV6 +0.05 AV4 +0.11 AV5 +0. 07 AV6 +0.09 AV7 +0.05 AV4 +0. 05 AV5 +0.05 AV6 +0. 05 AV7 +0.05 AV2 +0.12 L-2019-064 Enclosure Page 52 of89 Page 4 of 11 ROW COL %TW LOCATION 26 AV3 +0.14 36 AV4 +0.10 30 AV5 +0.07 86 77 21 AV4 +0.05 28 AV5 +0.05 38 AV6 +0.05 33 AV7 +0.00 86 79 23 AV3 +0.12 86 83 25 AV4 +0.00 29 AV5 +0.02 27 AV6 +0.07 86 87 26 AV5 +0.00 86 86 86 86 86 86 86 87 87 32 AV4 +0.00 24 89 33 31 32 23 91 34 32 33 97 27 29 27 21 99 25 101 27 29 33 37 28 103 32 38 27 24 26 105 21 20 66 21 70 24 30 AV3 -0.05 AV6 -0.02 AV5 -0.03 AV4 -0.05 AV3 -0.05 AV6 +0.00 AV5 +0.00 AV4 +0.00 AV3 +0.05 AV5 +0.07 AV6 +0.07 AV7 +0.05 AV6 +0.07 AV3 +0. 02 AV4 +0.08 AV5 +0. 05 AV6 +0.09 AV7 +0.07 AV2 +0.05 AV3 +0.00 AV4 +0.03 AV6 +0.05 AV7 +0.00 AV3 +0. 05 AV7 +0.07 AV5 +0.07 AV4 +0.08 AV5 +0.09 32 AV6 +0.12 32 AV7 +0.07 87 72 21 AV4 +0.16 87 87 87 87 87 87 87 74 80 82 84 86 88 90 36 22 34 25 20 35 30 29 24 31 24 26 29 27 35 34 20 32 33 23 29 26 26 22 36 37 21 20 AV5 +0.07 AV6 +0.07 AV7 +0.02 AV5 +0.07 AV3 +0.12 AV4 +0.08 AV5 +0.09 AV6 +0.07 AV3 +0. 05 AV4 +0.05 AV5 +0.05 AV6 +0.05 AV7 +0.05 AV4 +0.05 AV5 +0.05 AV6 +0.07 AV7 +0.07 AV6 -0.07 AV5 -0.05 AV4 -0.07 AV3 -0.05 AV5 -0.05 AV4 -0.07 AV7 -0.05 AV6 +0.02 AV5 +0.00 AV4 -0.07 AV3 -0.07

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 87 92 31 AV3 +0.07 26 AV4 +0.05 37 AV5 +0.09 27 AV7 +0.07 87 96 21 AV2 +0.07 39 AV3 +0.05 31 AV4 +0.05 22 AV5 +0.05 87 100 30 AV2 +0.08 29 AV3 +0.07 31 AV4 +0.11 21 AV5 +0.05 87 106 21 AV2 +0.07 22 AV4 +0.08 26 AV6 +0.09 87 108 27 AV3 +0.09 23 AV4 +0.08 87 114 28 AV6 +0.07 30 AV7 +0.05 88 69 28 AV6 +0.05 23 AV7 +0.02 88 71 29 AV4 +0.08 30 AV5 +0.05 32 AV6 +0.07 29 AV7 +0.09 88 73 30 AV2 +0.14 21 AV3 +0.14 22 AV4 +0.10 27 AV6 +0.07 23 AV8 +0.07 88 75 26 AV6 +0.02 31 AV7 +0.02 24 AV8 +0.05 88 79 20 AV5 +0.05 88 81 25 AV3 +0.12 24 AV4 +0.05 33 AV5 +0.02 24 AV6 +0.05 88 83 22 AV3 +0.08 88 87 21 AV6 +0.00 21 AV4 +0.00 21 AV3 +0.00 88 89 25 AV6 +0.00 23 AV5 -0.03 30 AV4 -0.05 88 91 33 AV6 -0.02 26 AV4 -0.05 88 93 26 AV5 +0.10 35 AV6 +0.09 88 95 28 AV3 +0.09 36 AV4 +0.08 27 AV5 +0.02 88 97 25 AV4 +0.13 88 99 21 AV3 +0.14 30 AV4 +0.11 27 AV6 +0.09 88 101 30 AV3 +0.07 20 AV4 +0.05 25 AV5 +0.05 26 AV6 +0.09 88 107 22 AV3 +0.17 24 AV7 +0.07 88 109 26 AV3 +0.12 20 AV4 +0.09 89 70 21 AV7 +0.02 89 72 22 AV4 +0.03 33 AV5 +0.05 23 AV6 +0.00 89 74 21 AV3 +0.14 26 AV5 +0.09 32 AV6 +0.09 28 AV7 +0.07 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 89 78 25 AV4 +0.05 21 AV5 +0.05 89 82 31 AV4 +0.03 22 AV5 +0.05 22 AV6 +0.05 34 AV7 +0.05 89 84 24 AV6 +0.05 33 AV7 +0.05 89 90 33 AV3 +0.13 30 AV4 +0.05 37 AV5 +0.07 38 AV6 +0.05 89 92 26 AV3 +0.08 20 AV6 +0.07 89 96 20 AV3 +0.15 89 100 24 AV2 +0.07 27 AV3 +0.09 35 AV4 +0.08 38 AV5 +0.09 37 AV6 +0.09 27 AV7 +0.05 89 102 32 AV2 +0.07 33 AV3 +0.14 31 AV4 +0.16 21 AV7 +0.05 89 106 21 AV4 +0.14 90 69 25 AV4 +0.08 33 AV5 +0.09 39 AV6 +0.12 25 AV7 +0.07 90 73 28 AV3 +0.07 25 AV5 +0.02 27 AV7 +0.05 90 75 20 AV5 +0.05 27 AV6 +0.02 23 AV7 +0.05 90 79 25 AV5 +0.05 90 83 22 AV5 +0.12 90 85 22 AV4 +0.03 35 AV5 +0.07 29 AV6 +0.07 30 AV7 +0.07 90 87 23 AV3 +0.10 22 AV4 +0.08 34 AV5 +0.07 30 AV6 +0.07 90 91 29 AV3 +0.10 32 AV4 +0.05 35 AV5 +0.02 36 AV6 +0.02 90 97 29 AV2 +0.07 30 AV3 +0.09 35 AV4 +0.03 37 AV5 +0.00 32 AV6 +0.05 29 AV7 +0.05 90 99 25 AV3 +0.07 32 AV4 +0.05 28 AV5 +0.07 25 AV2 +0.07 90 103 33 AV3 +0.09 31 AV4 +0.08 28 AV5 +0.09 24 AV6 +0.07 26 AV7 +0.02 90 105 23 AV4 +0.05 30 AV5 +0.07 29 AV6 +0.07 32 AV7 +0.07 91 64 22 AV5 +0.05 91 66 20 AV5 +0.09 91 68 20 AV7 +0.05 L-2019-064 Enclosure Page 53 of 89 Page 5 of ll ROW COL %TW LOCATION 91 70 23 AV5 +0.00 91 72 26 AV3 +0.17 34 AV5 +0. 05 28 AV6 +0.02 26 AV7 +0.05 91 76 28 AV7 -0.02 35 AV6 -0.02 38 AV5 +0.00 32 AV4 +0.00 91 80 24 AV7 -0.05 32 AV6 -0.05 27 AV5 -0.05 29 AV4 -0.07 91 82 24 AV7 -0.07 22 AV6 -0.08 26 AV5 -0.08 32 AV4 -0.12 91 84 36 AV7 -0.02 35 AV6 -0.02 38 AV5 -0.05 33 AV4 -0.09 91 88 39 AV7 -0.05 23 AV6 -0.05 31 AV5 -0.03 33 AV4 -0.09 91 90 27 AV7 -0.05 36 AV6 +0.00 35 AV5 -0.03 27 AV4 -0.05 91 92 26 AV7 -0.02 31 AV6 -0.02 28 AV4 -0.02 30 AV3 -0.02 91 94 38 AV7 -0.02 30 AV6 -0.02 39 AV5 +0.02 25 AV3 -0.02 24 AV2 +0.00 91 96 27 AV7 +0.00 25 AV6 +0.00 36 AV5 -0.03 31 AV4 -0.02 36 AV3 +0.02 91 98 25 AV6 +0.00 35 AV5 +0.02 31 AV4 -0.02 33 AV3 -0.02 91 100 25 AV3 +0.14 26 AV6 +0.09 22 AV7 +0.05 91 106 22 AV3 +0.07 36 AV4 +0.08 91 108 20 AV4 +0.03 30 AV5 +0. 05 30 AV6 +0.07 21 AV3 +0.07 91 110 28 AV4 +0.10 34 AV5 +0.05 91 112 25 AV2 +0.12 91 116 20 AV4 +0.05 22 AV6 +0.02 92 69 22 AV6 +0.07 92 73 33 AV3 +0.02 22 AV4 +0. 05 31 AVS +0.02 38 AV6 +0.02 92 75 26 AV8 -0.02 38 AV7 -0.07 32 AV6 -0.05 30 AV5 -0.05 21 AV4 -0.02 92 79 36 AV7 -0.05

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 36 AV6 +0.00 30 AV5 -0.03 92 81 28 AV7 -0.05 37 AV6 -0.02 39 AV5 -0.03 37 AV4 -0.05 37 AV3 +0.00 22 AV2 +0.00 92 83 34 AV6 -0.02 34 AV5 -0.08 32 AV4 -0.09 21 AV3 -0.07 92 85 28 AV7 -0.05 24 AV6 -0.02 27 AV5 -0.05 26 AV4 -0.07 29 AV3 -0.07 92 87 22 AV6 -0.02 26 AV5 -0.05 20 AV4 -0.05 92 89 29 AV6 -0.02 20 AV5 -0.03 25 AV4 -0.05 92 91 21 AV7 -0.05 36 AV6 +0.00 35 AV5 -0.03 32 AV4 -0.05 25 AV2 -0.02 92 99 29 AV7 -0.05 30 AV6 -0.05 24 AV5 -0.03 28 AV4 -0.05 24 AV3 -0.07 92 101 26 AV3 +0.16 92 103 33 AV3 +0.12 33 AV4 +0.10 24 AV5 +0.07 23 AV6 +0.12 92 105 28 AV4 +0.10 34 AV5 +0.07 21 AV6 +0.07 93 70 21 AV6 +0.07 93 72 37 AV6 +0.09 34 AV7 +0.02 28 AV8 +0.09 28 AV4 +0.10 93 76 22 AV8 +0.00 36 AV7 -0.05 24 AV4 -0.07 93 78 26 AV7 -0.05 20 AV6 -0.03 28 AV5 -0.03 20 AV2 -0.02 93 82 28 AV7 -0.05 20 AV6 -0.05 23 AV5 -0.05 24 AV4 -0.07 93 88 33 AV7 -0.05 24 AV6 -0.02 25 AV5 -0.05 20 AV4 -0.07 93 92 22 AV7 -0.05 37 AV6 +0.00 34 AV5 -0.05 39 AV4 -0.05 29 AV3 -0.07 93 102 20 AV3 +0.09 36 AV4 +0.13 33 AV5 +0.05 31 AV6 +0.05 93 104 29 AV7 +0.02 30 AV3 +0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 27 AV4 +0.05 35 AV5 +0.05 37 AV6 +0.05 93 106 21 AV3 +0.14 29 AV4 +0.13 24 AV7 +0.04 93 110 26 AV4 +0.05 30 AV5 +0.07 94 67 23 AV6 +0.07 23 AV7 +0.05 94 71 26 AV4 +0.08 21 AV5 +0.07 23 AV6 +0.05 34 AV7 +0.07 94 77 32 AV6 -0.02 25 AV4 -0.07 94 79 22 AV6 -0.05 94 81 29 AV7 -0.05 30 AV6 -0. 05 26 AV5 -0.05 94 87 23 AV7 +0.00 37 AV6 +0.00 38 AV5 +0.00 30 AV4 -0.02 29 AV3 -0.02 94 91 33 AV7 -0.05 33 AV6 -0.02 33 AV5 -0.08 33 AV4 -0.07 23 AV2 -0.05 94 95 31 AV7 -0.07 35 AV6 +0.00 27 AV4 -0.05 25 AV3 -0.02 94 97 20 AV6 -0.02 22 AV4 -0.02 94 99 22 AV7 -0.05 36 AV5 -0.03 36 AV4 -0.02 20 AV3 -0.02 94 101 23 AV2 +0.10 21 AV3 +0.14 26 AV5 +0.12 21 AV6 +0.12 94 103 20 AV2 +0.05 37 AV3 +0.00 37 AV4 +0.03 26 AV5 +0.02 30 AV6 +0.07 94 105 30 AV3 +0.07 34 AV4 +0.08 32 AV6 +0. 07 30 AV7 +0.07 95 74 21 AV6 +0.05 95 78 23 AV5 -0.10 95 80 24 AV6 -0.03 32 AV4 -0.07 95 82 27 AV7 -0.05 21 AV6 -0.05 31 AV5 -0.03 35 AV4 -0.05 95 84 36 AV5 -0.05 34 AV4 -0.07 23 AV3 -0.07 24 AV2 -0.07 95 88 29 AV7 -0.02 29 AV6 +0.00 37 AV5 -0.03 34 AV4 -0.05 95 90 28 AV8 -0.02 33 AV6 +0.00 33 AV5 -0.03 L-2019-064 Enclosure Page 54 of 89 Page 6 of 11 ROW COL %TW LOCATION 33 AV4 -0.05 28 AV3 -0.05 20 AV2 +0.00 95 94 25 AV7 -0.05 31 AV4 -0.07 30 AV3 -0.07 95 96 30 AV6 -0.02 33 AV5 -0.03 20 AV4 -0.05 95 98 24 AV6 +0.00 28 AV5 +0.00 22 AV3 -0.05 95 100 31 AV5 +0.07 33 AV6 +0.07 27 AV7 +0.05 95 104 22 AV3 +0.14 24 AV5 +0.05 96 67 25 AV5 +0.02 24 AV6 +0.05 96 71 22 AV4 +0.13 31 AV5 +0.05 28 AV6 +0. 05 31 AV7 +0.05 96 73 27 AV4 +0.08 33 AV5 +0.07 33 AV6 +0.07 38 AV7 +0.00 25 AV8 +0.07 96 75 32 AV7 -0.05 29 AV6 +0.00 29 AV5 -0.05 22 AV4 -0.05 96 77 39 AV6 +0.00 32 AV5 +0.03 34 AV4 -0.02 96 79 24 AV7 -0.02 37 AV6 +0.00 34 AV5 -0.03 32 AV4 -0.05 35 AV3 -0.02 96 81 22 AV5 -0.05 96 91 24 AV7 -0.05 34 AV6 +0.00 36 AV5 +0.00 31 AV4 -0.02 23 AV3 -0.02 96 95 27 AV6 +0.02 23 AV5 +0.00 96 97 23 AV4 -0.02 96 101 27 AV3 +0.09 24 AV6 +0.09 25 AV7 +0.05 96 103 23 AV2 +0.05 37 AV3 +0.05 23 AV4 +0.05 30 AV6 +0.05 96 105 29 AV5 +0.09 30 AV6 +0.07 26 AV7 +0.07 97 66 22 AV2 +0.14 97 68 34 AV4 +0.08 23 AV5 +0.07 26 AV6 +0.09 20 AV7 +0.05 97 72 25 AV4 +0.13 36 AV5 +0.07 35 AV6 +0. 07 97 74 25 AV3 +0.07 24 AV5 +0.07 36 AV6 +0.07 31 AV7 +0.07 97 76 28 AV7 -0.05

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 38 AV6 -0.03 36 AV5 -0.03 24 AV4 -0.05 97 80 30 AV6 +0.00 31 AV5 +0.00 38 AV4 +0.00 97 82 20 AV7 -0.05 28 AV4 +0.00 97 96 22 AV6 -0.05 32 AV5 -0.03 32 AV4 -0.07 29 AV3 -0.05 97 98 27 AV5 -0.03, 32 AV4 -0.05 32 AV3 -0.07 31 AV2 +0.00 97 102 32 AV5 +0.05 33 AV6 +0.07 34 AV7 +0.00 26 AV2 +0.09 25 AV3 +0.07 98 71 21 AV3 +0.07 98 73 22 AV3 +0.07 26 AV4 +0.08 35 AV5 +0.05 33 AV6 +0.07 32 AV7 +0.00 98 75 23 AV8 -0.02 29 AV6 -0.02 27 AV5 -0.08 22 AV4 -0.09 98 77 35 AV6 -0.05 35 AV5 -0.03 32 AV4 -0.05 98 79 25 AV6 -0.02 31 AV5 -0.03 21 AV4 -0.05 31 AV3 -0.05 98 81 28 AV7 -0.05 29 AV6 -0.05 23 AV5 -0.05 25 AV3 -0.05 98 93 21 AV7 -0.05 25 AV6 -0.05 22 AV5 -0.05 35 AV4 -0.05 20 AV3 -0.05 98 95 29 AV5 +0.00 38 AV4 +0.00 25 AV3 -0.05 29 AV2 +0.00 98 99 30 AV4 -0.05 30 AV3 -0.05 98 101 25 AV4 +0.05 32 AV5 +0. 07 34 AV6 +0.07 98 105 21 AV2 +0.07 29 AV3 +0.14 36 AV4 +0.10 24 AV5 +0. 05 29 AV6 +0.07 25 AV7 +0. 05 98 107 23 AV6 +0.09 99 68 21 AV4 +0.08 25 AV6 +0.07 99 72 28 AV5 +0.05 28 AV6 +0.07 99 74 24 AV4 +0.08 31 AV5 +0.07 39 AV6 +0.07 22 AV7 +0.07 99 76 26 AV6 -0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 36 AV5 -0.03 31 AV4 -0.05 99 78 35 AV7 -0.02 23 AV6 -0. 02 23 AV3 -0.02 23 AV2 +0.00 99 80 25 AV4 -0.07 99 96 25 AV5 -0.03 23 AV3 -0.02 99 98 20 AV8 +0.00 23 AV7 -0.05 99 104 23 AV5 +0.05 22 AV7 +0.09 99 106 22 AV5 +0.07 25 AV6 +0.07 100 69 28 AV7 +0.05 100 71 26 AV5 +0.07 29 AV6 +0.05 22 AV7 +0.05 100 73 21 AV3 +0.05 30 AV5 +0.07 31 AV6 +0.05 36 AV7 +0.00 24 AV8 +0.09 100 75 32 AV7 -0.05 28 AV6 +0.00 30 AV5 -0.03 32 AV4 -0.07 34 AV3 -0.02 30 AV2 -0.02 100 77 22 AV5 -0.05 26 AV4 -0.05 20 AV3 -0.05 24 AV8 -0.02 33 AV7 -0.07 35 AV6 -0.08 100 79 32 AV2 -0.05 33 AV6 -0.03 34 AV5 -0.03 27 AV4 -0.07 34 AV3 -0.05 100 81 30 AV7 -0.05 34 AV6 -0.07 34 AV5 -0.05 100 91 22 AV7 -0.05 32 AV6 -0.02 34 AV5 -0.03 24 AV4 -0.07 100 95 28 AV6 +0.00 21 AV5 -0.03 100 99 26 AV7 -0.05 100 101 24 AV3 +0.12 33 AV5 +0.07 23 AV6 +0.09 100 105 30 AV4 +0.03 31 AV5 +0.03 24 AV6 +0.02 25 AV7 +0.07 100 107 29 AV6 +0.07 23 AV7 +0.09 23 AV3 +0.12 21 AV4 +0.10 101 72 25 AV4 +0.05 33 AV5 +0.09 39 AV6 +0.07 36 AV7 +0.09 39 AV8 +0.09 101 74 21 AV3 +0.12 24 AV4 +0.08 32 AV5 +0.05 29 AV6 +0.05 101 76 32 AV7 -0.05 L-2019-064 Enclosure Page 55 of 89 Page 7 of 11 ROW COL %TW LOCATION 38 AV6 -0.03 29 AV5 -0.03 26 AV4 -0.05 20 AV3 -0.05 101 78 20 AV7 -0.05 21 AV6 -0.05 101 80 28 AV6 -0.05 25 AV5 -0.05 39 AV4 -0.07 101 82 27 AV7 -0.05 39 AV6 -0.05 22 AV5 -0.05 20 AV4 -0.07 101 88 32 AV6 -0.02 35 AV5 -0.05 22 AV4 -0.09 36 AV3 -0.07 30 AV2 -0.02 101 90 38 AV7 -0.02 27 AV6 -0.02 30 AV5 -0.03 28 AV3 -0.09 24 AV2 -0.02 26 AV8 -0.02 101 94 23 AV8 -0.02 22 AV7 -0.07 101 96 26 AV3 -0.02 21 AV2 +0.00 101 98 20 AV8 -0.02 101 100 25 AV6 +0.07 102 71 23 AV4 +0.10 31 AV5 +0.05 33 AV6 +0.05 20 AV7 +0.05 102 73 25 AV5 +0.05 102 75 33 AV6 -0.05 27 AV5 -0.03 102 77 34 AV6 -0.07 34 AV5 -0.03 29 AV4 -0.07 102 79 22 AV7 +0.00 31 AV5 +0.02 102 91 30 AV5 -0.05 30 AV4 -0.02 102 95 34 AV6 -0.02 23 AV4 -0.05 102 97 26 AV4 -0.05 102 99 24 AV5 -0.03 29 AV4 -0.02 103 72 36 AV4 +0.10 33 AV5 +0.02 21 AV6 +0.02 103 78 20 AV6 -0.02 35 AV5 -0.05 28 AV4 -0.07 24 AV3 -0.07 103 80 21 AV7 -0.03 25 AV6 -0.02 103 82 21 AV8 -0.02 33 AV7 +0.00 32 AV6 +0.00 30 AV5 -0.03 29 AV4 -0.02 103 90 32 AV7 -0.02 23 AV6 -0.02 39 AV5 -0.03 30 AV4 -0.05 103 92 34 AV7 -0.05 37 AV6 -0.02 28 AV5 +0.00 27 AV4 -0.05 32 AV3 -0.07

Frarnatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVE Wear 20-39%

ROW COL %TW LOCATION 103 94 28 AV7 -0.02 34 AV6 -0.02 38 AV5 +0.02 24 AV4 -0.05 25 AV3 -0.05 103 96 33 AV7 -0.05 24 AV6 -0.02 29 AV5 -0.08 103 100 21 AV3 +0.09 24 28 30 103 104 22 103 106 24 104 71 21 104 73 22 21 104 75 33 29 36 34 31 104 77 26 30 104 79 22 104 91 23 21 25 28 21 25 104 97 22 23 32 AV4 +0. 05 AV5 +0.07 AV6 +0.09 AV4 +0. 08 AV5 +0.07 AV5 +0.05 AV6 +0.07 AV4 +0.08 AV7 -0.02 AV6 +0.00 AV5 -0.03 AV4 -0.05 AV3 -0.02 AV6 -0.03 AV4 -0.05 AV4 -0.07 AV5 -0.08 AV4 -0.09 AV3 -0.07 AV2 -0.05 AV7 -0.02 AV6 -0.02 AV6 -0.02 AV5 -0.05 AV4 -0.05 104 105 22 AV5 +0.10 24 AV6 +0.07 27 AV7 +0.09 105 72 27 AV4 +0.10 29 AV5 +0.07 105 74 29 AV4 +0.05 34 AV5 +0.05 29 AV6 +0.07 105 76 28 AV6 -0.03 28 AV5 -0.05 32 AV4 -0.05 20 AV7 -0.02 105 78 20 AV6 -0.02 105 80 20 AV7 -0.07 20 AV6 -0.05 24 AV5 -0.05 105 82 24 AV6 -0.07 32 AV5 -0.05 30 AV4 -0.05 21 AV3 -0.05 105 94 28 AV7 -0.05 28 AV6 -0.02 35 AV4 -0.05 33 AV3 -0.05 105 96 23 AV5 -0.05 105 98 22 AV6 -0.05 24 AV5 -0.05 105 100 20 AV4 +0.08 22 AV5 +0.05 106 71 25 AV5 +0.07 106 73 27 AV4 +0.05 30 AV5 +0.05 32 AV6 +0.07 33 AV7 +0.09 106 75 20 AV8 -0.02 33 AV7 -0.02 22 AV6 +0.00 26 AV5 -0.03 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 106 77 20 AV6 -0.05 25 AV5 +0.00 26 AV4 -0.07 106 79 30 AV7 +0.00 38 AV6 +0.02 33 AV5 +0.02 22 AV3 +0.02 106 93 30 AV6 +0.00 30 AV5 +0.00 29 AV4 +0.00 106 95 34 AV6 -0.05 37 AV5 -0.05 34 AV4 -0.05 106 97 25 AV3 -0.02 106 99 25 AV6 -0.02 20 AV5 +0.00 106 101 26 AV4 +0.13 106 103 23 AV5 +0.02 24 AV6 +0.07 107 68 24 AV7 +0.05 107 70 29 AV4 +0.05 23 AV5 +0.05 20 AV3 +0.07 107 86 21 AV7 +0.00 27 AV6 -0.05 24 AV4 -0.05 22 AV3 -0.07 107 90 35 AV7 -0.02 30 AV6 -0.05 35 AV5 -0.05 23 AV4 -0.07 107 94 24 AV7 +0.00 36 AV6 +0.00 39 AV5 +0.05 30 AV4 +0.00 22 AV3 -0.05 107 96 28 AV7 +0.00 20 AV6 +0.00 20 AV3 +0.00 107 98 20 AV5 -0.03 20 AV3 -0.05 107 100 22 AV4 +0.13 26 AV5 +0.05 107 102 24 AV3 +0.14 20 AV6 +0.07 108 71 20 AV4 +0.13 36 AV5 +0.09 25 AV6 +0.07 108 75 20 AV7 +0.00 22 AV6 +0.00 37 AV5 -0.06 108 77 27 AV7 +0.00 34 AV6 +0.00 25 AV5 -0.03 22 AV4 -0.02 23 AV3 -0.02 108 81 25 AV7 -0.02 20 AV6 +0.00 20 AV5 +0.00 29 AV3 -0.02 21 AV2 -0.02 108 91 21 AV7 -0.03 30 AV6 -0.02 34 AV5 -0.03 33 AV4 -0.05 31 AV3 -0.09 25 AV2 -0.02 108 93 20 AV7 -0.05 25 AV6 +0.00 24 AV5 -0.03 21 AV4 -0.05 28 AV3 -0.07 L-2019-064 Enclosure Page 56 of89 Page 8 of 11 ROW COL %TW LOCATION 20 AV2 -0.05 108 99 26 AV6 -0.02 27 AV5 -0.03 37 AV4 -0.05 31 AV3 -0.07 28 AV2 -0.05 108 101 26 AV2 +0.07 25 AV3 +0.12 108 103 23 AV3 +0.09 23 AV4 +0.03 108 105 22 AV6 +0.05 109 68 36 AV2 +0.07 26 AV3 +0.09 22 AV5 +0.12 109 70 20 AV6 +0.05 109 74 24 AV4 +0.10 33 AV5 +0.09 29 AV7 +0.07 109 76 22 AV7 +0.00 27 AV6 +0.05 28 AV4 +0.03 109 82 26 AV7 -0.02 35 AV6 -0.02 32 AV5 +0.00 21 AV4 -0.02 28 AV3 -0.02 22 AV2 -0.02 109 88 33 AV7 -0.02 33 AV6 -0.02 27 AV5 -0.05 20 AV4 -0.05 109 92 25 AV7 -0.05 27 AV6 -0.05 22 AV4 -0.05 27 AV3 -0.07 109 94 20 AV6 -0.02 109 98 23 AV6 -0.02 109 100 27 AV4 +0.13 29 AV5 +0.09 36 AV6 +0.12 35 AV7 +0.07 109 102 30 AV3 +0.09 31 AV4 +0.11 27 AV6 +0.07 23 AV7 +0.04 110 69 30 AV6 +0.02 27 AV7 +0.05 110 71 27 AV2 +0.05 34 AV4 +0.03 36 AV5 +0.02 24 AV6 +0.05 110 73 22 AV2 +0.00 20 AV3 +0.05 24 AV4 +0.05 26 AV5 +0.07 110 75 27 AV5 -0.03 26 AV4 -0.02*

25 AV3 -0.02 110 77 28 AV6 +0.00 32 AV5 +0.00 36 AV4 -0.05 29 AV3 +0.02 110 79 27 AV7 +0.00 34 AV6 +0.00 25 AV5 -0.03 20 AV4 +0.00 110 81 26 AV5 -0.03 21 AV4 -0.05 110 93 25 AV6 -0.02 20 AV5 -0.05 28 AV4 -0.07 31 AV3 -0.05

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 22 AV2 -0.05 110 95 36 AV7 -0.05 39 AV6 -0.05 27 AV4 -0.07 25 AV2 -0.05 110 101 24 AV4 +0.05 110 103 24 AV3 +0.05 23 AV4 +0.08 31 AV5 +0.05 20 AV6 +0.05 111 68 20 AV3 +0.09 38 AV4 +0.11 33 AV5 +0.12 28 AV6 +0.07 111 72 28 AV6 +0.05 111 74 22 AV5 +0.05 26 AV6 +0.09 111 76 22 AV6 -0.02 111 80 28 AV7 -0.05 22 AV6 -0.02 29 AV5 -0.05 111 82 20 AV7 -0.05 33 AV5 -0.05 28 AV4 -0.05 111 86 27 AV6 -0.02 30 AV5 +0.00 34 AV4 -0.02 27 AV3 -0.05 28 AV2 -0.07 111 94 21 AV8 +0.00 36 AV7 -0.02 39 AV6 +0.02 20 AV5 +0.02 23 AV2 +0.00 111 98 21 AV5 +0.02 112 69 20 AV6 +0.05 112 73 20 AV4 +0.08 112 75 24 AV5 -0.03 112 77 22 AV5 -0.05 24 AV6 +0.00 112 79 23 AV7 -0.02 35 AV6 -0.05 31 AV5 -0.03 24 AV4 -0.07 22 AV3 -0.07 112 81 112 83 112 87 112 93 22 AV6 -0.05 26 AV5 -0.05 26 AV7 -0.05 26 AV6 -0.02 24 AV5 -0.05 34 AV4 -0.07 22 AV3 -0.09 33 AV7 +0.00 34 AV6 -0.02 32 AV5 -0.05 26 AV4 -0.05 28 AV3 -0.05 24 AV2 -0.02 21 AV7 -0.02 20 AV6 +0.00 26 AV4 -0.05 26 AV3 -0.07 21 AV2 -0.05 112 95 21 AV7 -0.05 32 AV6 -0.02 20 AV5 -0.03 21 AV2 -0.02 112 97 27 AV3 -0.02 112 99 30 AV3 +0.00 29 AV2 +0.00 112 103 22 AV3 +0.16 23 AV4 +0.19 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 32 AV5 +0.07 113 72 22 AV2 +0.07 38 AV3 +0.09 38 AV4 +0. 05 30 AV5 +0.09 33 AV6 +0. 07 113 74 35 AV4 +0.10 29 AV5 +0.12 31 AV6 +0.12 113 76 21 AV6 +0.00 21 AV3 -0.05 113 78 29 AV7 +0.00 29 AV6 -0.02 31 AV5 -0.05 24 AV4 -0.05 113 80 27 AV7 -0.02 26 AV6 -0.02 20 AV3 -0.02 113 88 26 AV7 -0.02.

29 AV6 -0.05 24 AV5 -0.05 30 AV4 -0.07 113 90 29 AV7 +0.00 27 AV6 +0.00 32 AV5 -0.05 27 AV4 -0.07 23 AV3 -0.09 113 94 20 AV6 -0.05 21 AV5 -0.05 113 102 21 AV6 +0.09 114 75 24 AV5 -0.05 114 77 26 AV3 -0.02 114 79 25 AV7 -0.05 30 AV6 -0.03 27 AV5 -0.03 114 81 26 AV3 -0.09 114 87 26 AV5 -0.05 31 AV4 -0.07 30 AV3 -0.07 114 91 27 AV7 -0.02 32 AV6 -0.02 34 AV5 -0.03 20 AV4 -0.09 22 AV3 -0.09 114 101 26 AV4 +0.13 31 AV5 +0. 07 115 66 28 AV2 +0.15 29 AV6 +0.16 21 AV7 +0.11 115 72 29 AV6 +0.07 115 74 31 AV2 +0.05 35 AV3 +0.09 20 AV6 +0. 07 115 80 26 AV7 -0.02 32 AV6 -0.02 32 AV5 -0.03 115 82 24 AV6 -0.05 33 AV5 -0.05 27 AV4 -0.07 27 AV3 -0.07 115 92 24 AV5 -0.10 28 AV4 -0.09 115 102 27 AV2 +0.07 29 AV3 +0.07 116 81 34 AV6 -0.05 35 AV5 -0.03 25 AV4 -0.07 23 AV3 -0.07 116 91 22 AV6 -0.02 26 AV5 -0.05 116 93 28 AV5 +0.00 21 AV3 -0.07 L-2019-064 Enclosure Page 57 of 89 Page 9 of 11 ROW COL %TW LOCATION 116 95 26 AV6 +0.00 28 AV5 -0.05 117 68 25 AV6 +0.05 117 70 25 117 76 21 117 80 23 28 35 117 92 20 AV6 +0.07 AV6 -0.02 AV7 -0.02 AV6 -0.05 AV5 -0.03 AV6 -0.02 22 AV4 -0.09 25 AV3 -0.09 23 AV2 -0.07 117 94 31 AV6 +0.02 34 AV5 +0.05 117 98 26 AV4 -0.05 118 77 27 AV6 -0.02 31 AV5 -0.08 118 81 32 AV6 -0.05 35 AV5 -0.08 118 91 20 AV6 +0.02 24 AV5 +0.00 23 AV3 -0.05 119 72 35 AV4 +0.08 119 76 27 AV6 -0.02 20 AV5 +0.00 119 80 25 AV7 -0.02 27 AV6 -0.03 119 88 20 AV7 +0.00 27 AV4 -0.07 20 AV3 -0.05 119 96 24 AV5 +0.07 120 79 23 AV7 -0.05 120 81 23 AV7 -0.02 33 AV6 -0.05 27 AV5 -0.05 120 91 27 AV5 -0.05 20 AV4 -0.07 120 93 26 AV8 +0.00 27 AV7 +0.02 22 AV6 +0.02 27 AV4 +0.00 25 120 99 20 28 33 24 25 120 103 28 121 78 33 23 121 82 35 121 90 29 22 23 22 121 92 31 28 22 27 22 121 94 25 31 22 AV3 -0.02 AV6 -0. 02 AV5 -0.05 AV4 -0.05 AV3 -0.07 AV2 -0.05 AV5 +0. 00 AV6 +0.02 AV5 +0.05 AV6 +0.00 AV6 -0.02 AV5 -0.05 AV4 -0.09 AV3 -0.09 AV7 -0.05 AV6 +0.00 AV4 -0.05 AV3 -0.09 AV2 -0.07 AV7 -0.02 AV6 -0.02 AV5 -0.05 122 79 20 AV7 +0.00 29 AV6 -0.02 29 AV5 -0.05 22 AV4 -0.07 22 AV3 -0.09 122 81 22 AV8 +0.02 27 AV7 -0.02 30 AV6 -0.08 23 AV5 -0.08

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 122 83 29 AV7 +0.00 33 AV5 +0.00 27 AV4 -0.05 32 AV3 -0.07 23 AV2 -0.05 122 87 28 AV5 -0.03 122 101 23 AV2 +0.07 25 AV3 +0.05 33 AV4 +0.03 123 72 32 AV5 +0.00 37 AV6 +0.05 22 AV7 +0.07 123 80 21 AV7 +0.00 123 88 32 AV5 -0.05 28 AV3 -0.07 123 90 20 AV8 +0.02 25 AV7 +0.00 22 AV6 -0.02 25 AV4 -0.05 32 AV3 -0.09 23 AV2 -0.07 123 92 21 AV6 -0.02 123 94 23 AV7 +0.00 25 AV6 +0.00 20 AV4 -0.05 124 63 21 AV3 +0.09 28 AV4 +0.05 124 69 24 AV2 +0.10 124 73 124 77 124 79 28 20 31 28 27 24 21 25 25 AV3 +0.07 AV5 +0.05 AV6 +0.05 AV7 +0.09 AV4 +0.00 AV6 +0.05 AV7 +0.00 AV7 -0.02 AV6 -0.02 27 AV5 -0.05 31 AV2 -0.05 124 87 21 AV5 -0.05 124 91 27 AV5 -0.05 35 AV4 -0.09 20 AV2 -0.07 124 99 24 AV5 +0.05 22 AV4 +0.00 125 72 23 AV6 +0.12 125 76 23 AV6 +0.02 34 AV5 +0.02 24 AV4 +0.00 125 80 20 AV8 +0.02 30 AV7 +0.02 20 AV5 +0.07 125 82 25 AV7 +0.00 35 AV6 -0.05 33 AV5 -0.08 36 AV4 -0.07 125 88 35 AV7 -0.02 35 AV6 -0.05 34 AV5 -0.08 27 AV4 -0.09 125 90 24 AV7 +0.00 37 AV6 -0.05 35 AV5 -0.05 37 AV4 -0.07 125 92 22 AV6 -0.05 20 AV5 -0.10 126 69 21 AV3 +0.09 24 AV7 +0.14 126 77 25 AV6 -0.05 32 AV5 -0.05 127 76 20 AV5 +0.07 127 88 37 AV6 -0.05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G A ROW COL %TW LOCATION 22 AV5 -0.10 26 AV3 -0.12 20 AV2 -0.07 127 90 22 AV8 +0.05 31 AV7 +0.00 32 AV6 -0.02 35 AV5 -0.05 26 AV4 -0.07 127 92 22 AV3 -0.14 23 AV2 -0.05 127 96 28 AV5 -0.03 22 AV4 -0.05 128 67 24 AV2 +0.00 31 AV3 -0.05 22 AV4 -0.07 29 AV5 -0.03 128 73 24 AV6 +0.05 128 87 26 AV5 -0.03 21 AV4 -0.05 20 AV3 -0.07 20 AV2 -0.02 128 93 24 AV8 +0.02 38 AV7 +0.02 28 AV6+0.00 128 95 22 AV7 -0.02 33 AV6 -0.05 128 99 33 AV7 -0.02 21 AV6 -0.05 21 128 117 24 32 22 129 66 25 129 78 22 129 80 22 36 35 AV4 -0.07 AV6 +0.09 AV7 +0.09 AV8 +0.14 AV6 +0.14 AV6 +0. 02 AV8 +0. 05 AV7 +0. 02 AV6 -0.03 35 AV5 +0.00 35 AV4 -0.05 129 86 24 AV7 -0.02 20 AV6 -0.02 129 88 38 AV7 -0.02 25 AV5 -0.08 129 104 21 AV6 +0.07 21 AV7 +0.09 130 79 25 AV7 +0.02 35 AV6 +0.02 29 AV5 +0.02 130 93 33 AV3 +0.00 34 AV2 -0.02 130 95 25 AV7 +0.02 34 AV6 +0.05 130 97 24 AV6 +0.02 21 AV3 +0.00 21 AV2 +0.00 131 70 28 AV4 +0.05 131 74 33 AV4 +0.13 29 AV5 +0.17 26 AV6 +0.14 27 AV7 +0.14 131 78 32 AV6 +0.00 28 AV5 +0.00 27 AV4 -0.05 131 82 26 AV7 -0.02 20 AV6 -0.05 131 88 22 AV7 +0.00 21 AV5 -0.05 27 AV4 -0.09 131 92 20 AV7 -0.05 22 AV5 -0.03 20 AV3 -0.07 32 AV2 -0.07 L-2019-064 Enclosure Page 58 of 89 Page 10 of 11 ROW COL %TW LOCATION 131 94 32 AV7 -0.02 21 AV6 -0.02 32 AV4 -0.09 22 AV3 -0.12 132 69 22 AV3 +0.12 28 AV6 +0.14 132 79 30 AV7 -0.02 31 AV6 -0.02 24 AV5 -0.05 132 81 26 AV6 -0.05 132 93 26 AV8 +0.05 34 AV7 +0.00 28 AV6 +0.00 132 99 20 AV5 +0.02 133 68 22 AV2 +0.02 27 AV6 +0.00 133 70 24 AV7 +0.02 133 72 20 AV7 +0.04 133 74 23 AV7 +0.07 133 86 28 AV7 +0.00 28 AV6 +0.00 33 AV5 -0.03 27 AV3 -0.07 28 AV2 -0.09 133 88 20 AV6 -0.07 133 92 23 AV7 +0.00 32 AV4 -0.09 31 AV3 -0.07 133 96 134 73 134 79 25 29 22 20 24 20 27 27 36 AV2 -0.09 AV3 -0.02 AV2 -0.07 AV4 +0.00 AV6 +0.00 AV7 +0. 05 AV6 -0. 07 AV5 -0.13 AV4 -0.14 21 AV3 -0.12 134 83 30 AV7 +0.00 23 AV6 -0. 02 34 AV5 -0.05 134 87 31 AV6 +0.02 33 AV5 +0. 00 134 97 20 AV4 -0.12 20 AV3 -0.09 135 70 23 AV3 +0.07 29 AV4 +0.05 135 74 24 AV3 +0.07 24 AV4 +0.13 135 78 35 AV5 +0.00 26 AV4 -0.07 22 AV3 -0.05 135 90 22 AV8 +0.05 26 AV7 -0.02 28 AV5 -0.10 39 AV4 -0.12 37 AV2 -0.11 135 92 36 AV7 +0.02 29 AV6 -0.02 32 AV5 -0.08 21 AV4 -0.09 28 AV3 -0.07 24 AV2 -0.09 135 94 21 AV7 +0.00 136 75 25 AV7 -0.02 29 AV6 +0. 00 24 AV5 -0.05 136 77 21 AV8 +0.02 35 AV4 -0.09 136 83 28 AV7 -0.02 26 AV6 -0.07 35 AV5 -0.08

Framatome Inc.

Customer: FPL Plant:

09/18 -

EOC23 Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 38 AV4 -0.14 33 AV3 -0.14 136 85 21 AV2 -0.09 136 91 32 AV7 +0. 02 30 AV5 +0.00 22 AV3 -0.02 136 93 30 AV7 -0.02 34 AV6 +0.00 20 AV5 +0.00 26 AV4 -0.02 24 AV3 -0.07 137 80 30 AV7 -0.02 39 AV6 -0.05 29 AV3 -0.09 137 84 26 AV6 -0.05 37 AV5 -0.08 28 AV4 -0.09 137 92 23 AV2 -0.14 138 79 24 AV5 -0.08 139 78 29 AV5 -0.03 23 AV4 -0.05 139 92 27 AV7 +0.02 Total Tubes 775 Total Records: 2182 Appendix F: Wear <40% at AVBs St Lucie Unit: 2 Component: S/G A ROW COL %TW LOCATION L-2019-064 Enclosure Page 59 of 89 Page 11 of 11 ROW COL %TW LOCATION

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 33 164 6 AV7 +0.20 34 165 8 8

35 6

8 36 159 5 36 163 7 36 165 7 37 6

8 37 164 7 38 163 7 38 39 39 7

165 7 6

7 6

8 7

6 AV7 +0.23 AV2 -0.34 AV7 -0.19 AV2 +0.25 AV7 +0.16 AV2 -0.37 AV7 -0.27 AV2 -0.34 AV7 +0.16 AV2 -0.23 AV7 +0.21 AV7 +0.07 AV2 -0.19 AV7 +0.22 AV8 -0.02 39 162 7 AV2 +0.09 39 164 7 AV8 +0.18 9

AV7 +0.18 12 AV2 -0.23 40 161 6 AV7 +0.09 40 41 41 41 42 42 42 43 43 43 44 44 163 10 7

6 6

8 7

164 9 7

7 9

5 163 7 6

10 5

162 6 164 7 7

7 8

11 9

8 44 11 5

5 44 161 6 44 163 8 11 12 12 AV7 +0.14 AV2 -0.18 AV2 -0.11 AV7 +0.25 AV7 -0.27 AV7 +0.23 AV2 +0.10 AV7 -0.29 AV3 -0.30 AV2 +0.23 AV6 +0.11 AV7 -0.30 AV6 +0.19 AV7 +0.27 AV3 -0.19 AV2 -0.09 AV1 -0.15 AV8 +0.22 AV6 +0.16 AV8 +0.15 AV6 +0.20 AV3 -0.25 AV2 -0.23 AV6 +0.28 AV7 +0.20 AV3 -0.23 AV3 -0.21 AV8 -0.25 AV7 -0.27 AV6 +0.16 AV3 -0.27 AV2 -0.16 AV1 +0.02 AV3 -0.23 AV7 +0.25 AV3 -0.20 45 45 45 45 46 46 46 46 46 46 47 47 47 8

8 6

12 8

160 7 162 8 7

6 9

7 6

7 13 11 9

6 9

AV6 +0.25 7

AV7 +0.20 11 6

AV3 -0.21 17 7

AV3 -0.17 161 10 AV6 +0.16 9

AV2 -0.18 163 7 AV8 +0.18 10 AV6 +0.23 7

AV2 -0.28 6

AV3 -0.17 8

10 AV2 -0.12 8

AV6 +0.23 10 11 AV3 +0.45 12 7

AV3 -0.19 6

AV7 +0.22 Appendix F: Wear <40% at AVBs Dnit: 2 Component: S/G B ROW COL %TW LOCATION 47 14 5

AV2 +0.14 6

AV3 +0.38 47 16 5

AV3 +0. 40 47 24 6

AV3 +0.41 47 158 6 AV6 -0.18 47 160 6 AV7 +0.14 7

AV3 +0.06 6

AV2 -0.14 5

AV1 +0.19 47 162 11 AV6 +0.09 8

AV3 -0.24 7

AV2 -0.16 48 7

14 AV3 -0.17 8

AV7 +0.30 6

AV8 +0.24 48 9

9 AV2 -0.19 6

7 8

48 11 8

48 161 7 12 5

163 6 48 49 49 49 49 49 49 49 15 8

7 9

9 10 11 12 6

11 14 5

24 8

156 7 158 8 49 7

160 9 8

49 162 7 50 50 50 50 50 50 50 50 50 51 51 51 7

8 7

9 11 11 6

9 7

11 11 7

7 7

13 6

7 15 6

157 6 9

159 6 8

8 161 8 13 6

163 7 7

8 8

9 10 17 10 6

10 8

7 14 9

AV3 -0.20 AV6 +0.25 AV7 +0.25 AV3 -0.14 AV7 +0.14 AV6 +0.14 AV2 +0.06 AV3 +0.28 AV2 -0.30 AV2 -0.20 AV6 +0.23 AV7 +0.21 AV3 +0. 45 AV2 -0.07 AV3 -0.14 AV3 +0. 33 AV3 +0. 32 AV3 +0.26 AV7 +0.14 AV6 +0.12 AV7 +0.11 AV2 -0.21 AV7 +0.14 AV3 -0.26 AV2 -0.23 AV2 +0.30 AV3 -0.17 AV7 +0.27 AV7 -0.21 AV2 -0.09 AV7 +0.20 AV1 -0.11 AV3 -0.15 AV7 +0. 21 AV3 +0.41 AV7 +0.23 AV3 +0.42 AV7 -0.28 AV6 -0.09 AV7 -0.28 AV6 -0.40 AV3 +0.29 AV7 +0.14 AV6 +0.11 AV2 -0.12 AV7 -0.28 AV3 +0.30 AV2 -0.25 AV2 -0.07 AV3 -0.17 AV6 -0.22 AV7 +0.23 AV8 +0.18 AV3 +0.35 AV8 -0.14 AV2 -0.17 L-2019-064 Enclosure Page 60 of89 Page 1 of 27 ROW COL %TW LOCATION 6

AV3 -0.18 51 16 8

AV3 +0.39 51 24 11 AV3 +0.41 51 156 6 AV6 -0.39 6

AV3 +0.28 51 158 6 AV6 +0.07 7

AV3 -0.15 51 160 6 AV7 +0.16 7

AV2 -0.19 51 162 9 AV7 -0.09 11 AV3 -0.22 9

AV2 -0.21 5

AV1 +0.05 52 9

6 AV8 +0. 20 9

AV2 -0.12 11 AV7 +0.25 52 11 6

9 9

8 AV1 +0. 07 AV3 -0.22 AV6 +0.21 AV7 +0.23 AV2 -0.17 AV3 +0.39 AV3 -0.18 AV3 +0.14 AV3 -0.15 AV3 -0.09 AV6 +0. 00 AV8 +0.12 AV6 -0. 09 AV1 -0.04 AV7 +0.16 AV6 +0.16 AV1 -0.11 AV2 -0.09 AV3 -0.20 AV7 +0.25 AV8 +0.20 AV2 -0.12 52 13 8

52 52 52 52 52 52 52 53 8

17 6

19 7

23 11 39 6

151 6 159 6 7

7 161 8 14 6

8 5

10 11 6

53 10 9

12 AV3 +0.40 8

AV6 +0.00 53 14 6

AV2 -0.05 53 53 53 53 53 53 54 54 54 54 8

8 16 9

10 10 24 9

AV3 -0.15 AV8 +0.04 AV3 +0.35 AV6 -0.20 AV7 +0.00 AV3 +0. 44 AV6 -0.33 AV2 -0.16 AV7 +0.16 AV6 -0.11 AV3 +0. 08 AV8 +0. 09 AV7 +0.16 AV3 -0.19 AV2 -0.19 AV7 -0.35 154 6 158 5 10 8

10 160 8 8

7 10 162 9 9

11 13 15 8

AV6 +0.16 15 AV3 -0.20 7

AV1 -0.11 14 AV2 -0.17 13 AV3 -0.20 13 AV6 +0.02 9

AV8 +0.23 7

AV2 -0.07 8

AV3 +0.09 6

AV7 +0.18 7

AV8 +0.04 7

AV1 +0.07 9

AV3 +0.20 7

AV7 +0.16 8

AV7 +0.04

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 54 29 7

AV3 -0.10 54 153 9 AV6 -0.08 54 155 9 AV6 -0.38 54 157 6 AV7 +0.14 54 159 6 AV8 +0.11 8

AV7 +0.12 11 AV6 -0.08 8

AV3 +0.31 7

AV1 -0.07 54 161 17 AV6 +0.14 10 AV3 -0.22 6

AV2 -0.19 8

AV1 -0.23 55 10 55 12 8

7 7

10 AV1 -0.13 AV7 +0.18 AV6 +0. 02 AV7 +0.05 9

AV8 +0.04 7

AV1 -0.07 7

AV2 -0.07 11 AV3 -0.12 55 14 13 AV3 -0.12 55 16 10 AV3 +0.30 9

AV6 -0.05 13 AV7 +0.02 7

AV8 +0.11 55 55 55 55 55 55 55 56 22 7

24 8

146 7 154 6 156 8 6

158 7 8

6 160 8 15 6

11 5

9 8

17 16 6

56 11 7

AV6 +0.21 AV3 +0.35 AV6 +0.09 AV7 -0.17 AV7 +0.14 AV6 -0.11 AV7 +0.16 AV6 +0.07 AV3 -0.02 AV8 +0.20 AV7 +0.14 AV3 -0.19 AV2 -0.16 AV1 +0.09 AV2 -0.12 AV3 -0.17 AV7 +0.23 AV8 +0.25 AV2 -0.09 10 AV3 -0.17 7

AV6 +0.26 7

AV7 +0.25 5

AV8 +0.20 56 13 7

AV2 -0.12 6

AV3 +0.35 7

AV7 +0.23 15 9

AV7 +0.07 17 7

AV3 +0.43 14 AV6 -0.20 56 56 56 56 56 56 56 56 11 AV7 +0.05 5

AV8 +0.00 23 7

AV3 -0.10 25 6

AV3 -0.10 51 7

AV3 -0.11 139 8 AV6 +0.14 145 7 AV7 -0.02 153 6 AV6 +0.07 56 155 6 AV7 +0.09 8

AV6 +0.09 56 157 11 AV7 +0.12 9

AV6 -0.05 7

AV2 +0.00 56 159 8 AV8 +0.14 5

AV7 +0.09 11 AV6 -0.41 8

AV3 +0.33 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 56 161 18 AV6 +0.26 14 AV6 -0.28 7

AV7 -0.28 12 AV3 -0.22 57 10 8

AV1 -0.13 7

AV2 -0.14 12 AV6 -0.25 12 AV7 +0.23 10 AV8 +0.22 57 12 7

AV7 +0.23 8

AV3 +0.41 57 14 9

AV3 +0.37 57 16 6

AV3 -0.05 57 57 57 57 20 7

24 13 130 7 144 9 AV3 +0.29 AV3 +0.36 AV6 -0.26 AV6 -0.11 57 148 6 AV1 -0.16 57 152 6 AV8 -0.07 8

AV6 -0.11 57 154 8 AV7 +0.12 8

8 57 156 7 8

8 57 57 58 58 58 158 12 11 11 9

6 160 10 10 12 9

9 11 13 13 17 7

6 10 10 7

10 58 15 7

7 AV6 +0.12 AV3 +0.13 AV7 -0.07 AV6 +0.14 AV2 -0.14 AV7 +0.16 AV6 +0.14 AV3 -0.11 AV2 -0.19 AV1 -0.02 AV8 +0.11 AV7 +0.11 AV2 -0.21 AV3 -0.19 AV6 -0.22 AV7 +0.23 AV8 +0.22 AV2 +0.10 AV3 -0.15 AV7 +0.25 AV3 +0. 05 AV7 +0.21 AV2 +0.20 AV3 +0.08 8

AV7 +0.07 58 17 5

AV3 -0.15 58 19 7

AV8 +0.02 58 23 7

AV3 -0.10 58 33 7

AV7 +0.07 58 51 7

AV3 -0.12 58 58 58 58 58 58 65 5

143 9 153 7 155 10 157 6 12 6

159 7 6

7 7

11 AV3 -0.12 AV6 +0.14 AV6 -0.11 AV8 -0.07 AV8 -0.28 AV7 +0.14 AV6 -0.39 AV2 +0.04 AV1 +0.00 AV8 +0.16 AV7 +0.16 AV6 -0.13 7

AV3 +0.05 58 161 19 AV6 +0.14 7

AV3 -0.22 59 10 8

AV1 -0.13 9

AV2 -0.05 8

AV3 -0.15 18 AV6 -0.25 14 AV7 +0.23 9

AV8 +0.18 L-2019-064 Enclosure Page 61 of 89 Page 2 of 27 ROW COL %TW 59 12 7

LOCATION AV2 -0.07 AV3 -0.07 AV6 +0.07 AV7 +0.16 9

7 12 59 14 6

AV2 -0.07 15 AV3 -0.05 7

AV6 +0.19 6

AV7 +0.23 59 16 7

AV7 +0.25 59 152 9 AV8 -0.07 59 154 6 AV7 -0.02 6

AV6 +0.10 59 156 6 AV7 +0.21 59 8

6 8

158 12 AV6 +0.12 AV3 +0.39 AV2 -0.12 AV7 +0.14 8

AV6 +0.09 12 AV3 -0.02 10 AV2 -0.09 9

AV1 -0.05 59 160 11 AV8 +0.14 12 AV7 +0.14 9

AV1 -0.18 60 11 7

AV1 +0.05 7

AV2 -0.07 60 60 60 60 60 13 15 17 21 23 14 8

11 7

7 9

11 10 11 7

10 9

8 12 5

7 9

60 25 6

8 AV3 +0.40 AV6 -0.23 AV7 +0.21 AV8 +0.22 AV1 -0.04 AV2 -0.09 AV3 -0.02 AV7 +0.16 AV8 +0.07 AV2 +0.12 AV3 +0.39 AV3 +0.16 AV6 -0.27 AV8 +0.02 AV1 -0.09 AV2 +0.10 AV3 -0.08 AV3 -0.03 AV7 +0.05 9

AV8 +0.02 60 51 6

AV3 +0.23 60 139 6 AV6 +0.17 60 143 6 AV6 +0.14 60 145 9 AV6 +0.07 60 149 16 AV6 -0.13 60 60 60 60 151 8 153 16 157 10 7

7 9

8 7

159 7 7

13 19 AV6 -0.10 AV6 -0.29 AV7 +0.16 AV6 +0.14 AV3 +0.31 AV2 +0.04 AV1 -0.02 AV8 +0.14 AV8 +0.19 AV7 +0.14 AV6 -0.08 AV2 +0.26 10 AV1 +0.21 16 AV3 +0.13 61 10 10 AV2 -0.17 13 AV3 -0.17 7

AV6 -0.24 15 AV7 +0.18 7

AV8 +0.20 61 12 7

AV1 -0.11 11 AV3 +0.38

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 7

AV6 +0.19 9

AV7 +0.21 61 14 7

AV2 -0.12 17 AV3 -0.05 8

AV6 +0.00 9

61 16 5

AV7 +0.25 AVl +0.10 7

AV2 +0.08 12 AV3 +0.34 8

AV6 +0.02 7

AV8 +0.05 61 18 7

AV2 +0.17 61 24 8

AV3 +0.36 61 26 7

AVl +0.09 6

AV3 -0.03 61 54 6

AV3 +0.10 61 142 7 AV6 -0.13 61 146 9 AV8 -0.02 12 AV7 -0.07 13 AV6 -0.10 61 152 9 AV6 -0.31 61 154 8 AV8 -0.17 12 AV7 -0.07 13 AV6 -0.10 61 156 9 AV6 -0.13 7

AV3 +0.10 11 AV7 +0.14 61 158 9 AV7 +0.16 14 AV6 -0.31 15 AV3 +0.34 7

AV2 -0.16 61 160 11 AV7 -0.26 11 AV3 -0.22 62 11 10 AVl -0.11 7

AV2 +0.10 12 AV3 +0.35 16 AV6 -0.19 14 AV7 +0.23 62 13 5

AVl -0.11 10 AV2 -0.09 16 AV3 -0.07 9

AV7 +0.23 7

AV8 +0.02 62 15 7

AV3 -0.07 9

AV7 +0.07 6

AV8 +0.20 62 17 10 AV3 -0.10 9

AV6 +0.00 62 62 62 62 62 62 62 62 62 62 62 62 62 7

5 19 10 7

21 10 13 23 8

29 5

31 6

39 8

8 43 5

131 8 139 8 149 7 155 6 157 12 10 7

7 7

159 6 9

11 AV7 +0.05 AV8 +0.25 AV6 -0.05 AV7 +0.00 AV6 +0.00 AV7 +0.02 AV3 -0.07 AV3 -0.02 AV3 -0.02 AV6 +0. 05 AV7 +0.02 AV3 +0.23 AV6 +0.02 AV6 +0.14 AV2 -0.05 AV8 -0.26 AV8 -0.07 AV7 +0.16 AV6 +0. 07 AV2 -0.23 AVl -0.07 AV7 +0.16 AV6 -0.33 AV3 +0.33 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 8

AV2 +0.27 63 12 7

AV3 -0.18 16 AV6 +0.00 9

AV7 +0.21 63 14 7

AV2 -0.15 12 AV3 -0.15 8

AV3 +0.39 15 AV6 -0. 03 63 16 7

AVl +0.07 9

AV3 +0.16 14 AV6 -0.03 9

AV7 +0.05 9

AV8 +0.00 63 18 5

AV2 +0.12 63 22 12 AV3 +0.16 10 AV6 +0. 02 63 26 5

AV6 +0.18 63 32 6

AV3 -0.02 63 68 6

AV2 +0.12 63 110 8 AV6 -0.03 63 150 12 AV6 -0.13 63 152 6 AV7 -0.07 10 AV6 -0.15 63 154 8 AV7 -0.05 14 AV6 -0.13 63 156 10 AV7 +0.19 8

AV6 +0.05 12 AV3 +0.38 7

AVl -0.09 63 158 7 AV8 +0.12 17 AV7 +0.16 10 AV3 -0.11 64 11 14 AV3 -0.17 7

AV6 -0.23 8

AV7 +0.23 64 13 7

AV2 -0.17 7

AV3 +0.31 9

AV6 -0.03 15 AV7 +0.02 12 AV8 +0.02 64 15 9

AV2 +0.08 9

AV3 +0.08 13 AV6 +0.02 7

AV7 +0.07 64 17 6

AV3 +0.13 64 19 6

AV8 -0.07 64 21 7

AV3 +0.16 64 23 10 AV3 -0.07 64 64 64 64 64 64 64 64 64 64 64 64 65 7

AV8 +0.07 27 7

AV3 -0.10 31 7

AV3 +0.02 33 7

AV6 +0.02 59 5

AV3 -0.24 67 6

AV3 +0.10 101 8 AV6 +0.25 107 5 AV3 +0.18 137 6 AV3 -0.02 6

AV7 -0.19 151 12 AV6 -0.15 153 10 AV7 +0.00 13 AV6 -0.08 157 7 AV8 -0.05 10 AV7 +0.16 10 AV6 -0. 08 10 AV3 +0. 08 17 AV2 -0.05 6

AVl -0.16 159 8 AV7 -0.31 9

AV6 -0.31 9

AV3 -0.11 8

AV2 +0.24 12 8

AVl -0.07 L-2019-064 Enclosure Page 62 of 89 Page 3 of 27 ROW COL %TW LOCATION 5

AV2 +0.27 9

AV3 +0.43 6

AV6 -0.22 8

AV8 +0.22 65 14 15 AV3 +0.16 65 16 5

AVl -0.11 9

AV3 +0.21 17 AV6 +0.00 65 18 6

AV3 +0.31 65 20 7

AV2 +0.13 65 22 6

AV3 +0.10 65 24 11 AV3 +0.34 14 AV6 +0. 02 65 32 7

AV3 +0.13 65 34 7

AV2 +0.14 10 AV3 +0.18 16 AV6 +0.02 65 38 5

AV3 +0.17 6

AV6 +0.00 65 52 7

AV3 +0.05 10 AV6 +0.05 7

AV7 +0.02 65 62 6

AV6 +0.07 65 64 9

AV3 +0.18 65 68 8

AV3 +0.10 7

AV6 +0.05 65 86 6

AV3 +0.13 65 104 10 AV6 +0.02 65 110 6 AV6 +0.00 65 130 13 AV7 -0.07 16 AV6 -0.05 13 AV3 +0.03 6

AV2 -0.02 65 132 5 AV6 -0.28 65 144 8 AV3 +0.03 65 148 15 AV3 +0.10 65 150 7 AVl -0.21 65 152 7 AV7 -0.21 10 AV6 -0.10 65 154 11 AV6 -0.10 65 156 9 AV7 -0.26 12 AV3 +0.32 7

AV2 -0.14 65 158 11 AV8 +0.09 7

AVl -0.18 66 13 8

AVl +0.12 15 AV2 +0.12 11 AV7 +0.25 8

AV8 +0.20 66 66 66 66 66 66 66 66 66 66 66 66 66 66 15 17 19 23 29 31 41 49 51 57 63 65 75 89 7

AVl +0.07 9

AV2 +0.12 11 AV3 -0.02 12 AV6 -0.03 8

AV7 -0.14 8

AV2 +0.10 9

AV3 +0.42 16 AV6 +0.02 12 AV7 +0.05 8

AV8 -0.07 12 AV3 +0.00 8

AV6 +0.05 5

AV2 +0.00 8

AV3 -0.05 9

AV6 +0.00 9

AV6 +0.00 7

AV6 +0. 07 8

AV6 +0. 00 7

AV6 +0.09 9

AV6 +0. 05 5

AV3 -0.05 6

AV3 -0.07 7

AV2 +0.00

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 7

AV3 +0.15 66 66 66 66 66 66 66 66 66 66 66 93 5

95 6

99 8

8 10 103 7 109 7 5

143 8 15 9

149 8 151 9 153 14 13 155 7 6

10 157 8 16 6

8 AV3 -0.07 AV2 +0.14 AV2 +0.11 AV3 +0.17 AV6 +0.05 AV6 +0.05 AV6 -0.03 AV3 -0.22 AV7 -0.05 AV6 -0.08 AV3 -0.02 AV6 -0.05 AV3 +0.10 AV8 -0.07 AV7 -0.05 AV7 +0.05 AV2 -0.07 AVl -0.02 AV6 -0.10 AV7 -0.26 AV2 -0.23 AVl -0.27 67 12 7

AV7 +0.23 AV8 +0.20 7

AVl -0.11 18 AV3 -0.07 8

AV6 +0.02 67 14 7

AVl -0.13 5

AV2 -0.14 8

AV3 +0.18 8

AV7 +0.23 10 AV8 +0.02 67 16 11 AV3 +0.08 18 AV6 +0.02 6

AV8 -0.12 67 18 7

AV7 -0.17 67 22 8

AV3 +0.13 67 34 8

AV2 +0.17 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 36 7

AV3 +0.13 58 9

AV6 +0.05 68 11 AV6 +0.07 70 8

AV3 +0.05 96 8

AV3 -0.02 98 4

AV3 -0.07 100 8 AV7 +0.05 102 7 AV3 +0.13 108 5 AV3 +0.00 7

AV2 +0.00 112 8 AV3 +0.02 114 6 AV2 +0.29 120 12 AV6 +0.00 9

AV3 -0.02 148 5 AV6 +0.12 150 8 AV3 +0.10 152 12 AV7 -0.05 13 AV6 -0.08 11 AV3 -0.07 9

AVl -0.05 154 9 AV7 -0.02 11 AV6 -0.10 9

AV3 +0.10 67 156 10 AV8 +0.15 10 AV7 -0.05 8

AV6 -0.13 16 AV3 +0.30 7

AV2 -0.09 8

AVl -0.18 67 158 9 AV8 +0.15 15 AV7 +0.12 7

AV6 +0.02 11 AV3 +0.28 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 6

AV2 -0.05 68 68 68 68 68 68 68 68 68 68 68 68 13 15 17 23 27 39 41 51 65 67 93 97 9

8 14 18 7

9 5

6 9

11 7

8 5

10 10 8

10 7

11 8

7 8

AVl -0.13 AV2 +0.31 AV3 +0.28 AV6 +0.02 AV7 -0.14 AV8 +0.25 AV2 +0.27 AV3 +0.31 AV6 -0.02 AV7 -0.14 AV8 +0.25 AV3 +0.33 AV7 +0.23 AV3 +0.07 AV6 +0.00 AV6 +0. 05 AV6 +0.00 AV3 +0.12 AV3 +0.09 AV3 +0.09 AV2 +0. 09 AV6 -0.05 68 101 13 AV6 +0.05 7

AV7 +0.05 68 109 9 AV7 -0.07 17 AV6 -0.04 14 AV3 +0. 02 68 113 11 AV6 -0.09 68 143 9 AV8 -0.05 10 AV6 -0.04 5

AV3 +0.07 68 147 9 AV6 -0.11 14 AV3 +0.09 9

AV2 +0.07 68 149 8 AV7 -0.07 11 AV3 +0.07 68 151 7 AV7 -0.02 68 153 8 AV8 +0.05 7

AV2 -0.16 155 8 AV3 +0.09 19 AV2 +0.02 10 AVl +0.05 68 68 69 69 69 69 69 157 11 AV8 -0.05 12 AV3 +0.27 13 AV2 -0.18 10 AVl -0.18 17 AV7 +0.25 16 AV7 -0.14 14 8

AV2 +0.18 12 AV7 +0.00 6

AV8 +0.23 16 9

AV3 +0.18 9

AV6 +0.05 18 9

AV6 +0.00 5

AV7 -0.12 8

AV8 +0.05 20 8

AV2 +0.05 24 8

AV2 +0.29 6

AV3 +0.36 69 28 5

AV7 -0.07 69 34 6

AV2 +0.07 7

AV3 +0.27 69 36 6

AV3 +0.40 10 AV6 +0.00 69 38 8

AV3 +0.28 69 46 6

AV3 +0.15 69 52 10 AV6 +0.05 11 AV7 +0.07 69 62 11 AV3 +0.09 16 AV6 +0. 05 8

AV7 +0.09 L-2019-064 Enclosure Page 63 of 89 Page 4 of 27 ROW COL %TW LOCATION 69 68 7

AV6 +0.07 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 69 74 6

76 8

80 4

82 5

84 7

100 6 102 6 104 16 6

110 5 126 8 138 5 142 6 148 13 7

152 8 8

9 154 9 7

156 8 12 AV3 +0.09 AV7 +0.00 AV2 -0.09 AV2 -0.09 AV2 -0.43 AV3 +0.15 AV6 +0. 02 AV6 -0.04 AV3 -0.05 AV6 +0. 00 AV6 -0.21 AV6 -0.06 AV6 -0.24 AV3 +0. 08 AV2 -0.02 AV6 -0. 09 AV3 +0.03 AVl +0.00 AV7 +0.14 AV3 +0.34 AV8 +0.12 AV7 -0.24 17 AV3 +0.34 9

AVl -0.18 70 13 7

AV2 +0.32 5

AV3 +0.12 70 15 7

AV2 +0.25 15 AV3 +0.17 19 AV6 +0.00 12 AV7 -0.14 9

AV8 +0.25 6

AVl -0.11 70 17 6

AV2 +0.20 15 AV3 +0.18 6

AV6 +0.12 5

AV7 -0.12 70 21 7

AV3 +0.26 8

AV6 +0.00 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 33 6

41 7

47 8

49 8

65 9

67 6

10 10 69 6

6 77 6

81 6

83 12 89 6

99 11 101 5 107 9 7

129 6 153 11 6

AV3 +0.20 AV3 +0.24 AV3 +0.06 AV7 +0.07 AV6 +0. 02 AV3 +0.06 AV6 +0.05 AV7 +0.05 AV2 +0.07 AV3 +0.04 AV6 +0.02 AV2 -0.07 AV3 +0. 02 AV2 +0.07 AV3 -0.02 AV6 -0.16 AV7 -0.05 AV6 -0.02 AV3 -0.22 AV8 -0.21 AV7 +0.12 7

AV6-0.17 70 155 13 AV6 -0.08 7

70 157 8 9

71 16 7

7 8

AV3 +0.20 AV7 -0.02 AV3 -0.13 AV2 +0.10 AV3 +0.25 AV6 -0.02 7

AV8 +0.20 71 18 12 AV3 +0.19 11 AV4 -0.13 6

AV8 +0.09

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 71 20 8

AV2 +0.15 6

AV3 +0.11 71 24 6

AV3 +0.29 71 28 6

AV1 +0.28 7

AV6 +0.05 71 62 16 AV6 +0.07 9

AV7 +0.05 71 76 10 AV7 +0.07 71 78 9

AV3 +0.00 71 80 9

AV2 +0.05 10 AV3 +0.02 7

71 88 7

71 92 5

71 96 8

AV6 +0. 02 AV2 -0.05 AV2 +0.12 AV3 -0.13 71 100 8 AV3 -0.07 71 104 7 AV7 -0.07 9

AV6 -0.02 71 106 16 AV7 -0.05 16 AV6 +0.00 71 126 8 AV3 -0.11 71 128 5 AV3 -0.16 71 130 4 AV7 +0.09 5

AV3 +0.12 71 132 8 AV6 -0.20 71 150 7 AVl -0.21 71 152 7 AV4 +0.55 71 154 10 AV8 -0.05 12 AV7 -0.02 7

AV3 +0.22 71 156 7 AV8 +0.17 7

AV7 -0.23 7

AV6 -0.16 9

AV3 +0.21 72 15 6

AVl +0.09 8

AV2 +0.29 8

AV3 +0.25 6

AV4 +0.00 12 AV6 +0. 02 7

AV7 -0.14 10 AV8 +0.20 72 17 6

AV1 +0.05 72 21 72 23 72 27 72 65 9

7 7

6 7

8 8

5 5

8 12 AV3 +0.28 AV6 -0.02 AV8 +0. 00 AV3 +0.28 AV7 +0.02 AVl +0.12 AV3 +0.14 AVl +0.09 AV2 +0.19 AV3 +0.15 AV6 +0.05 12 AV7 +0.05 72 67 6

AV6 +0.05 72 69 8

AV2 +0.05 6

AV3 +0.02 10 AV4 +0.12 4

AV6 -0.15 72 75 8

AV3 +0.00 7

AV4 +0. 08 9

AV5 -0.23 9

AV6 +0.00 72 77 9

AV6 +0.02 72 79 7

AV3 +0.04 72 85 7

AV2 -0.05 72 91 7

AV7 +0.09 72 99 8

AV3 -0.05 5

AV2 -0.16 72 101 7 AV3 -0.02 10 AV2 -0.02 72 103 10 AV6 +0.00 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 8

AV3 -0.09 72 72 72 72 72 105 8 147 6 151 15 153 7 8

155 8 AV5 -0.29 AVl -0.02 AV6 -0.04 AV6 -0.09 AV8 +0.05 AV8 -0.02 7

AVl -0.14 73 14 8

AV2 +0.10 73 16 11 AV6 +0.02 73 18 8

AV4 +0.20 73 20 5

AV4 +0.36 5

AV8 -0.14 73 22 11 AV3 +0.09 73 26 6

AVl -0.12 73 36 5

AV5 +0.24 73 48 7

AV3 +0.09 73 54 6

AV4 +0.39 73 56 8

AV2 +0.05 10 AV6 +0.07 12 AV7 +0.02 73 60 5

AV4 +0.33 73 62 7

AV6 +0.05 73 70 7

AV5 +0.09 73 76 19 AV3 +0.09 14 AV4 +0.07 16 AV6 +0.09 10 AV7 +0.02 73 80 6

AV2 -0.05 73 82 7

AV3 +0.00 73 84 7

AV2 -0.09 11 AV3 +0.09 6

AV4 +0. 33 7

AV5 -0.16 73 86 7

AV2 +0.05 73 88 7

AV2 +0.07 73 94 7

AV3 +0.09 73 96 8

AV6 +0.00 6

AV5 -0.10 7

73 98 8

8 13 73 73 73 73 73 73 73 73 102 10 104 7 110 6 116 9 13 144 6 150 11 6

152 10 154 8 AV3 -0.02 AV6 +0.12 AV5 -0.10 AV4 +0.00 AV6 -0.05 AV6 -0.02 AV5 -0.24 AV7 +0.00 AV6 -0.02 AV3 -0.18 AV6 -0.07 AVl -0.21 AV7 -0.05 AV8 -0.02 7

AV6 -0.02 7

AV3 +0.11 7

AVl -0.18 74 15 11 AV2 +0.17 5

AV3 +0.17 5

AVl +0.18 5

AV5 -0.17 8

AV6 -0.07 9

AV7 -0. 09 11 AV8 +0.27 74 17 6

AV3 -0.12 74 19 10 AV6 -0.02 74 21 7

AV3 +0.28 74 25 6

AV3 +0.14 74 27 6

AV5 -0.18 74 51 9

AV6 +0.07 7

AV7 +0.07 74 53 6

AV4 -0.05 8

AV5 -0.18 L-2019-064 Enclosure Page 64 of89 Page 5 of 27 ROW COL %TW LOCATION 74 65 6

AV1 +0.07 6

AV2 +0.09 12 AV4 +0.03 13 AV5 -0.12 19 AV7 +0.05 74 67 9

AV2 +0.07 11 AV6 +0.05 9

AV7 +0.05 74 69 12 AV4 -0.02 74 71 8

AV5 -0.16 7

74 75 8

9 8

9 AV6 +0. 05 AV2 +0.02 AV3 +0. 07 AV4 +0.00 AV5 -0.18 13 AV6 +0.02 8

AV7 +0.05 74 77 7

AV5 +0.20 74 79 8

AV5 -0.15 10 AV6 +0.05 8

AV7 +0.05 74 83 8

AV2 +0.12 9

AV4 +0.07 7

AV5 -0.16 74 85 8

AV2 +0.09 17 AV3 +0.09 10 AV4 +0.09 7

AV6 +0.07 14 AV7 +0.05 74 91 8

AV7 +0.05 74 93 7

AV6 +0.02 7

AV7 +0.02 74 95 7

AV4 -0.09 5

AV3 -0.07 9

AV2 -0.02 74 97 10 AV8 -0.05 7

AV7 -0.05 11 AV4 +0.18 10 AV3 +0.00 6

AV2 +0.00 74 99 11 AV7 -0.05 9

AV6 -0.05 74 74 74 74 8

101 10 11 11 10 8

103 8 7

105 7 6

107 11 AV5 -0.09 AV6 -0.07 AV5 +0.00 AV4 -0.07 AV3 +0.00 AV2 +0.02 AV5 -0.03 AV4 +0.15 AV7 -0.07 AV6 -0.09 AV7 -0.07 10 AV5 -0.06 74 137 12 AV3 -0.04 9

AV2 +0.00 74 151 9 AV6 -0.05 74 153 7 AV8 +0.14 7

AV5 -0.31 9

AV4 +0.25 75 16 7

AV1 -0.09 8

AV3 +0.28 7

AV7 +0.05 9

AVB +0.20 75 18 8

AV2 +0.14 6

AV3 +0.33 6

AV4 +0.37 6

AV5 -0.12 7

AV8 +0.20 75 20 5

AV5 -0.12 75 26 6

AVl +0.16 9

AV2 +0.07

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear l-19%

ROW COL %TW LOCATION 9

AV8 +0.07 75 36 13 AV4 +0.06 9

AV5 +0.04 75 54 6

AV4 +0.30 75 60 7

AV7 +0.05 75 62 7

AV4 +0.00 75 66 6

AV1 +0.21 11 AV2 +0.08 16 AV3 +0.09 12 AV4 +0.03 11 AV5 +0.07 75 74 6

AV3 +0.09 7

AV4 +0.06 10 AV5 +0.07 8

AV6 +0.05 75 76 10 AV5 -0.18 10 AV6 +0.09 7

AV7 +0.07 6

AV4 +0.00 75 75 75 75 75 75 75 75 75 78 8

AV3 +0.09 5

AV4 +0.18 80 5

AV2 -0.07 82 8

AV5 -0.06 7

AV3 +0.20 84 8

AV2 +0.02 8

AV5 +0.05 86 8

AV3 +0.05 8

AV4 +0.23 11 AV5 +0. 02 8

AV6 +0. 02 7

AV7 +0.02 88 7

AV2 +0.09 10 AV4 +0.03 12 AV5 +0. 07 11 AV6 +0. 05 8

AV7 +0.07 90 6

AV4 +0.12 94 6

AV4 +0.15 8

AV6 +0.05 98 8

AV6 -0.02 7

AV5 -0.06 11 AV4 -0.07 75 100 6 AV7 +0.02 75 75 75 75 75 75 75 75 75 5

10 6

104 10 14 12 9

106 8 11 10 10 108 10 7

126 7 138 6 144 7 150 6 152 6 6

6 12 154 9 10 7

6 AV6 +0. 00 AV5 +0.00 AV4 +0.00 AV7 -0.05 AV6 -0.02 AV5 +0. 00 AV4 -0.05 AV8 -0.05 AV7 -0.02 AV6 -0.02 AV3 +0.02 AV6 -0.05 AV4 +0.15 AV5 +0.00 AV4 +0.20 AV3 -0.20 AV3 +0. 00 AV8 +0.23 AV7 -0.26 AV5 -0.29 AV4 +0.18 AV7 +0. 07 AV5 -0.27 AV4 +0.21 AV1 -0.07 76 17 9

AV3 +0.25 10 AV8 +0.18 6

AV6 -0.14 76 19 6

AV7 +0.00 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 7

AV8 -0.09 76 21 8

AV1 +0.09 76 23 76 33 76 35 76 49 76 61 9

AV2 +0.12 13 AV5 +0.02 8

AV3 +0.10 7

AV4 +0.25 7

AV5 -0.14 8

AV3 +0.07 11 AV4 +0. 03 10 AV5 +0.02 16 AV6 +0.07 76 63 8

AV2 +0.14 17 AV4 +0.03 14 AV5 -0.14 76 65 6

AV1 +0.09 13 AV5 -0.14 16 AV6 +0.02 13 AV7 +0.00 6

AV8 +0.07 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 67 69 71 73 75 77 79 81 85 87 89 91 93 95 97 99 8

AV4 +0.20 18 AV5 +0.07 13 AV6 +0.05 5

AV7 -0.11 6

AV1 +0.12 12 AV2 +0.07 14 AV3 +0.08 16 AV5 -0.14 7

AV6 +0.07 5

AV6 +0.05 10 AV3 +0.00 11 AV4 -0.02 10 AV5 +0.02 10 AV6 +0.05 5

AV1 +0.17 13 AV2 +0.05 14 AV3 +0.05 17 AV4 +0.03 18 AV6 +0.05 11 AV7 +0.09 5

AV8 +0.23 7

AV4 +0.17 15 AV5 +0.02 11 AV6 +0.05 7

9 6

6 6

9 6

6 12 6

7 10 9

11 9

9 7

7 7

6 8

5 7

5 13 AV7 +0.02 AV6 +0. 07 AV7 +0.07 AV3 +0.24 AV5 +0.00 AV3 +0. 07 AV3 +0.12 AV4 +0.03 AV5 +0.05 AV6 +0.12 AV2 -0.09 AV7 +0.02 AV3 +0.05 AV4 +0.03 AV5 +0.07 AV6 +0.09 AV3 +0.07 AV4 +0.08 AV5 -0.08 AV4 +0.14 AV2 -0.02 AV1 +0.16 AV7 -0.05 AV5 -0.17 AV8 -0.05 15 AV7 -0.05 19 AV6 -0.02 17 AV5 -0.03 9

AV4 -0.05 L-2019-064 Enclosure Page 65 of 89 Page 6 of 27 ROW COL %TW LOCATION 7

AV3 -0.09 5

AV2 -0.28 7 6 101 6 7 6 103 6 8

9 76 135 6 76 139 6 76 151 7 9

AV5 -0.06 AV4 +0.14 AV3 -0.14 AV2 -0.12 AV4 +0.20 AV4 +0. 20 AV7 -0.02 AV6 -0.05 76 153 7 AV7 +0.02 10 AV5 -0.14 9

AV4 +0.11 6

AV3 +0.25 77 16 12 AV8 +0.18 77 18 7

AV2 +0.07 77 20 8

AV1 +0.12 77 77 77 77 77 77 77 77 77 15 7

12 19 11 14 22 6

24 15 10 11 13 6

46 6

48 11 52 6

62 7

18 13 8

64 9

7 8

68 7

70 6

4 77 72 5

AV2 +0.15 AV3 +0.15 AV5 -0.15 AV6 -0.02 AV7 +0.02 AV8 -0.02 AV2 +0.32 AV3 +0.32 AV4 +0. 05 AV5 +0.09 AV6 +0.05 AV7 +0.07 AV4 +0.14 AV6 +0. 05 AV3 +0.12 AV3 +0.09 AV5 +0.05 AV6 +0.07 AV7 +0.05 AV5 +0.07 AV6 +0.00 AV7 +0.07 AV7 +0.00 AV3 +0.18 AV5 +0.26 AV6 +0. 05 AV2 +0.09 AV3 -0.14 AV4 +0.06 AV5 +0.07 AV6 +0.09 AV5 +0. 02 AV2 +0.05 AV3 -0.12 AV4 +0.06 AV5 +0.00 AV6 +0.05 AV4 +0.11 AV3 +0.00 AV5 +0.12 AV6 +0.07 AV4 +0. 08 AV5 +0.00 AV6 +0. 07 AV2 +0.09 AV3 +0.05 AV5 +0.12 AV6 +0.12 AV7 -0.19 AV2 +0.07 AV3 +0.16 77 77 77 77 77 77 77 77 76 78 80 82 86 90 92 94 12 7

11 15 14 7

7 9

8 6

7 8

8 16 9

6 6

9 6

6 10 7

7 5

6 5

AV4 +0.14 5

AV5 -0.11 8

AV6 +0.05 77 96 13 AV7 -0.05

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 6

AV6 -0.02 5

AV5 -0.03 7

AV3 -0.09 6

AV2 +0.00 77 98 8

AV4 -0.05 77 100 7 AV3 -0.02 10 AV2 +0.00 5

AVl +0.18 77 104 9 AV5 -0.20 6

AV4 -0.20 77 106 9 AV6 -0.05 7

AV5 -0.03 77 110 12 AV5 -0.03 7

AV4 +0.11 77 140 7 AV5 -0.22 77 142 7 AV4 -0.05 6

AV2 -0.14 77 146 7 77 148 9 77 150 7 77 152 9 8

8 78 17 7

8 AV3 +0.00 AVl +0.00 AV6 -0.07 AV7 -0.09 AV4 +0.14 AV3 -0.11 AV3 +0.32 AV8 +0.22 78 19 9

AV4 +0.28 78 23 6

AVl +0.12 7

AV2 +0.13 8

AV3 +0.13 78 25 9

AV5 +0.00 78 27 8

AV5 +0.02 78 31 6

AV4 +0.25 78 43 5

AV3 -0.07 78 49 7

AV3 +0.09 78 63 9

AV4 +0.03 78 65 6

AV4 -0.14 14 AV6 +0.05 10 AV7 +0.02 78 69 7

AV3 +0.10 9

AV4 -0.17 8

AV5 -0.17 78 73 7

AV5 +0.07 78 75 11 AV2 +0.09 12 AV3 +0.09 12 AV4 +0.06 17 AV5 +0.05 8

AV6 +0. 05 78 77 8

AV4 +0.08 10 AV5 +0.07 78 81 8

AV2 +0.05 9

AV3 +0.00 78 83 10 AV3 +0.02 12 AV4 +0.03 10 AV5 +0.00 10 AV6 +0.05 7

AV7 +0.02 78 85 13 AV3 +0.05 10 AV4 +0.11 8

AV5 +0.10 6

AV7 +0.02 78 89 7

AV3 +0.00 7

AV6 +0.02 5

AV7 +0. 02 8

AV2 +0.09 78 93 7

AV3 -0.05 6

AV7 +0.05 78 95 9

AV5 -0.03 10 AV4 -0.05 78 97 7

AV8 -0.02 13 AV5 -0.08 7

AV4 -0.09 8

AV3 -0.04 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 9

AV2 +0.00 78 99 10 AV7 -0.05 8

AV3 +0.02 9

AV2 +0.02 78 101 13 AV6 +0.00 12 AV5 +0.00 7

AV4 -0.05 6

AV3 -0.02 15 AV2 +0.02 10 AVl -0.02 78 103 6 AV6 -0.05 8

AV5 -0.06 78 105 11 AV5 -0.03 15 AV4 +0.14 78 107 7 AV7 -0.05 7

AV6 -0.07 8

AV5 -0.08 78 109 8 AV6 +0.00 13 AV5 -0.05 78 113 7 AV6 -0.07 78 115 8 AV8 -0.07 78 149 9 AV5 +0.02 78 151 11 AV6 -0.10 78 153 8 9

8 8

AV8 +0.12 AV6 -0.10 AV5 -0.06 AVl -0.18 79 18 8

AVl +0.12 7

AV2 +0.14 10 AV6 +0.07 7

AV7 -0.07 6

AV8 +0.20 79 20 8

AVl +0.28 12 AV5 -0.15 79 22 8

AV3 +0.10 8

AV4 +0.25 79 24 7

AV2 +0.20 7

AV3 +0.24 79 26 7

AVl -0.14 79 32 7

AVl +0.09 6

AV4 +0.13 79 52 9

AV6 +0.07 9

AV7 +0.05 79 54 7

AV2 +0.07 79 60 6

AV3 +0.09 6

AV6 +0. 02 79 62 9

AV3 +0.10 9

AV4 +0.11 13 AV5 +0. 07 79 64 8

AV5 +0.07 8

AV3 +0.16 79 66 8

AV2 +0.12 15 AV3 +0.19 19 AV5 +0.07 15 AV6 +0.07 79 70 6

AV3 +0.05 8

AV4 +0.06 13 AV5 +0.19 9

AV6 +0.07 79 72 6

AV3 +0.07 9

AV5 +0.07 79 76 6

AV2 +0.09 6

AV3 -0.12 6

AV4 -0.16 7

AV5 -0.11 7

AV6 +0.07 79 78 7

AV5 +0.22 79 80 8

AV3 +0.14 9

AV4 +0.06 11 AV5 +0.05 79 82 7

AV3 +0.19 8

AV4 +0.11 L-2019-064 Enclosure Page 66 of 89 Page 7 of 27 ROW COL %TW LOCATION 15 AV5 +0.10 11 AV6 +0.05 8

AV7 +0.05 79 84 13 AV3 +0.10 8

AV4 +0.08 79 86 8

AV3 +0.09 8

AV4 +0.03 8

AV5 +0.07 8

AV6 +0.05 7

79 88 8

AV7 +0.05 AV2 +0.09 9

AV3 +0.09 10 AV5 +0.09 79 92 8

AV7 +0.12 79 94 9

AV2 +0.14 8

AV3 +0.07 8

AV4 +0.05 6

AV6 +0. 22 79 96 11 AV7 -0.02 13 AV6 +0.00 5

AV4 -0.16 9

AV3 +0.00 13 AV2 +0.00 8

AVl +0.00 79 98 12 AV5 -0.06 13 AV4 -0.05 79 100 11 AV5 -0.08 9

AV4 -0.05 6

AV3 -0.09 79 104 8 AV7 -0.07 6

AV6 -0.02 16 AV5 +0.00 19 AV4 -0.02 12 AV3 +0.05 7

AV2 +0.02 79 106 7 AV4 -0.07 10 AV3 -0.04 9

AV2 -0.02 79 108 11 AV6 -0.02 9

AV5 -0.08 7

AV4 -0.05 79 110 6 AV8 -0.05 16 AV4 -0.05 79 128 4 AV4 -0.09 79 132 13 AV7 -0.05 10 AV6 -0.07 79 136 6 AV4 -0.20 79 150 7 AV8 +0.05 6

AVl +0.02 79 152 10 AV7 -0.07 5

AV4 +0.17 7

AV2 -0.02 5

AVl +0.16 80 19 8

AVl +0.05 7

AV2 +0.12 7

AV3 +0.17 8

AV6 +0.07 6

AV7 +0.00 11 AV8 +0.11 80 21 9

AVl +0.05 13 AV2 +0.10 7

AV3 +0.34 9

AV4 +0.11 80 23 5

AV4 +0.24 5

AV6 +0.05 80 25 6

AV4 +0.08 80 27 7

AVl -0.14 80 29 5

AV4 +0.13 80 35 8

AV4 +0.22 8

80 37 8

80 51 8

AV7 +0.00 AV5 +0.02 AV7 +0.09

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 80 59 8

AV1 +0.12 11 AV4 -0.14 7

AV7 +0.05 80 63 7

AV2 +0.05 8

AV4 -0.15 12 AV6 +0.02 7

AV7 +0.05 80 65 15 AV2 +0.12 12 AV3 +0.09 15 AV4 +0. 05 18 AV5 +0.07 18 AV6 +0.05 8

AV7 +0.05 80 67 6

AV2 +0.12 80 69 9

AV2 +0.10 6

AV4 -0.12 8

AV5 -0.16 80 71 10 AV4 +0.11 15 AV5 +0.07 14 AV6 +0. 07 6

AV3 +0.10 80 73 7

AV4 +0.00 7

AV7 +0.12 80 75 11 AV4 +0.03 18 AV5 +0.02 17 AV6 +0.05 5

AV3 +0.12 80 77 10 AV3 +0.09 17 AV4 +0.05 11 AV7 +0. 05 80 79 8

AV3 +0.10 80 81 7

AV2 +0.12 9

AV3 +0. 02 9

AV5 +0.09 80 83 9

AV3 +0.05 13 AV4 +0.08 9

AV5 +0.05 80 85 11 AV3 +0.07 10 AV4 +0.14 8

AV6 +0.02 9

AV7 +0.05 80 87 12 AV2 +0.14 9

AV3 +0.09 11 AV4 +0.03 16 AV5 +0.02 12 AV6 +0.07 7

AV7 +0.07 80 89 7

AV2 +0.29 8

AV3 +0.14 7

AV7 +0.07 80 91 7

AV4 +0.03 9

AV3 +0.09 80 93 8

AV3 +0.09 9

AV6 +0. 02 10 AV7 +0.05 80 95 8

AV5 -0.05 5

AV4 -0.07 5

AV2 -0.18 80 97 6

AV6 -0.05 5

AV5 +0.19 5

AV4 -0.07 5

AV3 -0.14 6

AV2 -0.02 80 99 7

AV6 -0.05 10 AV5 -0.06 8

AV4 -0.05 5

AV2 -0.44 80 101 9 AV6 -0.02 10 AV5 +0. 00 6

AV4 -0.07 80 103 5 AV6 -0.05 80 105 5 AV6 -0.05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 5

AV5 -0.19 11 AV4 +0.11 80 109 6 6

80 115 5 80 125 5 80 135 8 6

80 139 6 AV6 -0. 02 AV4 -0.25 AV5 -0.25 AV5 -0.27 AV5 -0.08 AV3 +0.07 AV3 +0.05 80 143 7 AV3 +0.05 8

AV2 +0.02 80 145 9 AV4 -0.05 80 151 11 AV6 -0.07 6

AV2 +0.02 7

AV1 -0.05 81 22 7

AV5 +0.05 9

AV6 +0.14 9

AV1 -0.07 8

AV3 +0.18 81 26 5

AV2 +0.10 6

AV5 +0.25 81 28 8

AV1 +0.07 7

AV4 +0.11 6

AV5 +0.18 81 30 6

AV4 +0.24 81 36 7

AV4 +0.03 81 38 8

AV2 +0.14 8

AV4 +0.11 81 44 8

AV6 +0.05 81 52 6

AV3 +0.19 7

AV4 +0.11 10 AV5 +0.07 8

AV6 +0.12 81 54 10 AV4 +0.08 18 AV5 +0. 07 17 AV6 +0.05 81 56 8

AV3 +0.05 9

AV5 +0.05 81 64 13 AV3 +0.19 13 AV5 +0.09 8

AV4 +0.11 10 AV7 +0.07 81 66 13 AV3 +0.12 81 68 7

AV1 +0.12 6

AV2 +0.07 14 AV5 +0.07 10 AV6 +0.02 81 70 6

AV4 +0.11 17 AV6 +0.05 7

AV7 +0.07 15 AV5 -0.05 81 72 5

AV4 +0.03 9

AV5 +0. 07 81 74 10 AV2 +0.02 6

AV3 +0. 05 9

AV4 +0. 03 6

AV5 +0.07 81 76 11 AV4 +0.03 10 AV5 +0.05 7

AV6 +0.12 11 AV7 +0.05 81 78 11 AV4 +0.03 14 AV5 +0.07 13 AV6 +0.05 14 AV7 +0.02 81 80 7

AV3 +0.09 18 AV4 +0. 05 16 AV5 +0.05 10 AV6 +0.07 7

AV7 +0. 05 81 82 16 AV3 +0.05 13 AV4 +0.08 L-2019-064 Enclosure Page 67 of89 Page 8 of 27 ROW COL %TW LOCATION 16 AV5 +0.07 15 AV6 +0.05 8

AV7 +0.02 81 84 12 AV3 +0.05 11 AV4 +0. 00 9

AV5 +0.05 7

AV6 +0. 07 81 86 8

AV3 +0.09 17 AV4 +0.14 14 AV5 +0.07 8

AV6 +0.05 81 88 7

AV2 +0.09 9

AV3 +0.07 7

AV5 +0.02 81 90 8

AV6 +0.05 7

AV7 +0.02 81 92 10 AV2 +0.12 12 AV4 +0. 05 7

AV3 +0.09 11 AV5 +0.10 7

AV6 +0.02 81 94 7

AV4 +0.00 7

AV5 +0.12 81 96 12 AV6 -0.02 7

AV5 -0.03 7

AV4 -0.05 7

AV8 -0.07 17 AV7 -0.07 81 98 8

AV5 +0.05 9

AV4 +0.03 7

AV3 +0.05 8

AV2 +0.00 11 AV1 +0. 00 81 100 7 AV5 -0.03 81 106 13 AV4 +0.00 13 AV3 +0.05 10 AV2 -0.02 81 108 6 AV6 +0.00 81 150 8 AV1 -0.16 82 19 5

AV3 -0.10 82 21 7

AV1 +0.05 9

AV3 +0.17 8

AV4 +0.06 6

AV5 +0.05 82 23 9

AV1 +0.07 8

AV3 +0.07 7

AV4 +0.08 82 25 7

AV1 +0.09 9

82 27 6

82 31 7

82 33 8

82 41 8

82 43 8

82 59 9

6 82 61 9

7 82 65 9

AV4 +0.08 AV4 +0.05 AV5 +0.07 AV4 +0.24 AV3 +0.12 AV4 +0.11 AV3 +0.10 AV7 +0.07 AV5 +0.07 AV6 +0. 05 AV5 +0. 05 14 AV6 +0.05 10 AV7 +0.02 82 67 6

AV5 +0.00 7

AV6 +0.02 82 69 7

AV4 -0.16 82 71 11 AV2 +0.09 9

AV6 +0.05 82 73 10 AV2 +0.02 9

AV6 +0.09 7

AV7 +0.14 82 75 8

AV3 +0.07 15 AV4 +0.03 12 AV7 +0.05

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 82 77 13 AV4 +0.03 12 AV5 +0.02 18 AV6 +0.05 9

AV7 +0.05 82 79 7

AV3 -0.07 82 81 7

AV1 -0.10 9

AV3 +0.09 11 AV5 +0.12 82 83 9

AV3 -0.05 10 AV5 +0.00 14 AV6 +0.05 82 85 15 AV3 +0.10 14 AV4 +0.14 7

AV5 +0. 05 7

AV6 +0.05 7

AV7 +0. 05 82 87 12 AV3 -0.09 8

AV2 +0.09 10 AV4 +0.03 12 AV5 +0.05 13 AV6 +0.07 82 89 6

AV2 +0.07 7

AV4 +0.00 82 91 7

AV3 +0.07 82 93 6

AV2 +0.07 7

AV3 +0.09 8

AV4 +0.05 7

AV7 +0.07 82 95 9

AV6 -0.07 6

AV5 -0.05 8

AV4 -0.07 12 AV3 -0.05 10 AV2 -0.02 7

AV1 +0.02 82 97 11 AV7 -0.05 10 AV6 -0.05 17 AV5 -0.05 14 AV4 -0.07 13 AV3 +0.00 12 AV2 -0.02 82 99 7

AV8 -0.05 16 AV7 -0.05 15 AV4 -0.05 13 AV3 +0.00 9

AV2 +0.00 82 103 10 AV7 -0.02 8

AV4 -0.02 82 105 19 AV7 -0.05 19 AV6 -0.05 14 AV5 -0.05 6

AV4 +0.08 82 107 8 AV6 -0.02 11 AV5 +0.00 82 109 9 AV4 -0.07 6

AV3 -0.23 82 145 6 AV4 -0.02 6

AV3 -0.11 82 147 8 AV2 +0.02 82 149 9 AV2 -0.05 83 20 9

AV3 +0.17 83 22 7

AV2 +0.15 83 24 5

AV2 +0.31 83 26 8

AV4 +0.08 83 28 8

AV5 +0.09 83 32 9

AV1 +0.10 10 AV2 +0.14 83 36 8

AV3 +0.14 10 AV5 +0.05 83 38 6

AV5 +0.07 83 46 7

AV4 +0.11 83 52 9

AV6 +0.12 83 54 9

AV5 +0.12 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 10 AV6 +0. 05 9

AV7 +0.02 83 56 7

AV5 +0.05 11 AV6 +0. 07 10 AV7 +0.02 83 58 6

AV2 +0.10 9

AV4 +0. 05 83 60 7

AV4 +0.13 83 62 14 AV5 +0.07 11 AV6 +0. 07 15 AV7 +0.07 83 64 10 AV3 +0.14 18 AV5 +0.07 17 AV6 +0.05 13 AV7 +0. 05 83 66 10 AV2 +0.05 7

AV3 +0.12 16 AV4 +0.11 83 70 8

AV4 +0.03 14 AV5 +0.07 17 AV6 +0.05 8

AV7 +0.07 83 72 6

AV3 +0.07 83 74 14 AV5 +0.05 7

AV3 +0. 07 12 AV4 +0.05 83 76 7

AV4 +0.09 13 AV5 +0.05 18 AV7 +0.07 83 78 13 AV3 +0.09 17 AV4 +0.11 83 80 11 AV3 +0.05 14 AV4 +0. 03 18 AV5 +0.05 19 AV6 +0.02 9

AV7 +0.07 83 84 15 AV3 +0.09 8

AV4 +0.11 15 AV5 +0.07 13 AV7 +0.05 83 86 7

AV3 +0.09 13 AV4 +0.05 7

AV5 +0.12 7

AV6 +0.02 7

AV7 +0.05 83 88 8

AV2 +0.14 10 AV3 +0.17 5

AV4 +0. 05 7

AV5 +0.10 5

AV6 +0.00 83 90 5

AV2 +0.12 5

AV3 +0.00 6

AV4 +0.06 8

AV5 +0.07 6

AV6 +0. 02 83 92 11 AV5 +0.02 9

AV6 -0.02 7

AV7 +0.02 7

AV4 -0.09 83 94 11 AV4 +0.11 9

AV5 +0.10 8

AV6 +0.07 10 AV7 +0. 02 5

AV8 +0.05 83 96 10 AV8 -0.05 17 AV7 -0.02 8

AV6 +0.02 9

AV5 +0.00 5

AV4 -0.14 7

AV3 -0.05 8

AV2 -0.02 83 98 7

AV7 -0.02 L-2019-064 Enclosure Page 68 of 89 Page 9 of 27 ROW COL %TW LOCATION 16 AV6 -0.02 11 AV4 -0.05 7

AV3 -0.05 9

AV2 -0.07 83 100 10 AV6 -0.02 15 AV5 -0.03 9

AV4 +0.00 12 AV3 -0.02 83 102 12 AV7 -0.07 7

AV6 -0.05 10 AV5 +0.00 83 104 11 AV6 +0.00 10 AV5 +0.00 83 106 14 AV7 -0.05 17 AV6 -0.05 18 AV5 -0.03 17 AV4 -0.07 83 110 10 AV8 -0.02 11 AV6 -0.02 11 AV5 +0.02 83 128 4 AV4 -0.11 83 130 6 AV2 -0.02 83 136 8 AV3 -0.04 83 140 7 AV5 -0.27 83 146 7 AV2 -0.12 84 21 10 AV3 +0.19 8

AV6 +0.02 84 23 11 AV1 +0.09 10 AV3 +0.12 7

AV4 +0.06 6

AV7 -0.12 84 25 6

AV1 +0.21 7

AV4 +0.08 84 27 7

AV1 +0.22 8

AV4 +0.08 84 29 5

AV4 +0.13 5

AV8 +0.05 84 31 6

AV2 +0.22 84 33 7

AV4 +0.11 84 57 10 AV3 +0.12 9

AV4 +0.03 12 AV5 +0.07 84 63 8

AV3 +0.12 8

AV4 +0.03 15 AV6 +0.05 84 65 7

AV5 -0.13 13 AV6 +0.05 12 AV7 +0.02 84 67 8

AV1 +0.05 7

AV2 +0.12 11 AV4 +0. 08 7

AV7 -0.14 84 71 6

AV2 +0.05 10 AV4 +0.05 84 73 6

AV1 +0.10 15 AV2 +0.14 17 AV3 +0.07 18 AV5 +0.07 14 AV6 +0.02 84 75 8

AV3 +0.07 17 AV4 +0.03 19 AV6 +0.02 10 AV7 +0. 02 84 77 12 AV3 +0.09 18 AV4 +0.05 19 AV5 +0.07 84 79 6

AV5 +0.05 9

AV6 +0.09 84 81 8

AV3 +0.05 8

AV4 +0.09 16 AV5 +0. 02 84 83 8

AV2 +0.12

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 15 AV3 +0. 07 11 AV4 +0.08 14 AV5 +0.07 10 AV6 +0.09 84 85 7

AV2 +0. 07 84 84 84 84 84 84 13 AV3 +0.07 12 AV4 +0.08 13 AV5 +0.07 8

AV7 +0.05 87 8

AV3 +0.17 11 AV4 +0.08 12 AV5 +0.05 17 AV6 +0.05 AV7 +0.02 89 6

AV3 -0.02 6

AV4 -0.12 16 AV6 +0.02 6

AV7 +0.00 91 8

AV6 +0.07 7

AV7 +0.00 93 6

AV1 +0.16 7

AV2 +0.14 7

AV3 +0.09 9

AV5 +0.05 10 AV6 +0.05 7

AV7 +0.07 95 10 AV7 -0.07 5

AV6 -0.07 8

AV5 -0.05 5

AV4 -0.09 14 AV3 -0.05 14 AV2 -0.07 8

AV1 +0.00 97 4

AV8 -0.05 10 AV7 -0.07 6

AV6 -0.07 8

AV4 -0.07 7

AV3 -0.09 6

AV2 -0.05 84 99 12 AV3 -0.02 6

AV2 +0.09 12 AV7 -0.07 16 AV6 -0.07 17 AV5 -0.08 13 AV4 -0.05 84 101 10 AV6 -0.02 11 AV5 +0.00 13 AV4 -0.07 7

AV2 +0.00 84 103 19 AV6 -0.05 18 AV5 -0.05 6

AV4 -0.05 10 AV2 -0.07 84 105 15 AV7 -0.07 15 AV4 +0.00 7

AV2 +0.07 84 107 12 AV5 +0.00 7

AV4 +0.00 84 141 8 AV5 -0.05 84 143 8 AV2 +0.00 84 149 9 AV3 +0.09 9

AV2 +0.00 8

AV1 +0.00 85 22 8

7 8

6 85 24 6

6 8

85 26 7

8 AV2 +0. 07 AV6 +0.17 AV7 +0.00 AV8 +0.09 AV1 +0.07 AV4 +0.11 AV5 +0.07 AV1 -0.14 AV4 +0.06 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 5

AV5 +0.18 85 28 7

9 85 30 5

AV4 +0.11 AV5 +0.14 AV1 -0.05 7

AV2 +0.12 5

85 32 6

AV5 +0. 00 AV4 +0.11 85 36 85 44 85 56 85 60 85 62 85 64 85 66 85 70 85 72 85 74 85 76 85 78 5

AV4 +0.13 7

AV5 +0.07 15 AV5 +0.02 12 AV6 +0.02 8

AV2 +0. 08 8

AV7 +0.00 11 AV5 +0.07 13 AV5 +0.05 10 AV6 +0.07 8

AV4 +0.13 11 AV5 +0.07 9

AV6 +0.05 8

AV7 +0.07 8

AV3 +0.14 5

AV4 +0. 03 12 AV5 +0. 07 8

AV6 +0.12 7

AV4 +0. 03 12 AV7 +0.05 13 AV3 +0.10 6

AV4 +0.14 7

AV5 +0.10 6

AV6 +0.05 14 AV3 +0. 07 11 AV4 +0. 08 18 AV5 +0.07 15 AV7 +0.00 9

AV3 +0.05 11 AV4 +0.11 17 AV5 +0.05 18 AV6 +0.09 17 AV7 +0.05 85 80 8

AV5 +0.02 9

AV7 +0.05 85 82 8

AV6 +0.05 85 84 7

AV6 +0.07 85 86 7

AV6 -0.14 6

AV3 +0.09 7

AV4 +0. 03 9

AV5 +0.07 85 88 7

AV3 +0.14 85 90 6

AV3 +0.16 6

AV5 +0. 07 85 92 13 AV2 +0.14 11 AV3 +0.12 12 AV4 +0.08 8

AV5 +0.07 11 AV6 +0.12 10 AV7 +0. 05 85 94 6

AV2 +0.09 7

AV4 +0.05 8

AV5 +0.00 6

AV6 +0.05 5

AV7 +0.02 85 96 8

AV6 -0.05 8

AV5 -0.05 7

6 AV4 -0.05 AV3 -0.02 9

AV2 +0.00 7

AV1 -0.02 85 98 12 AV7 +0.00 19 AV5 -0.05 15 AV4 -0.07 8

AV3 +0.00 8

AV2 +0.00 L-2019-064 Enclosure Page 69 of 89 Page 10 of 27 ROW COL %TW LOCATION 85 100 9 AV6 -0.02 18 AV4 -0.05 85 85 7

102 6 7

104 18 7

AV3 -0.07 AV4 -0.02 AV3 +0.00 AV3 -0.02 AV6 -0.02 14 AV5 -0.03 19 AV4 -0.02 85 106 11 AV4 +0.00 10 AV3 +0.02 8

AV2 -0.05 85 108 7 AV3 +0.00 85 110 8 AV5 +0.16 7

AV4 -0.02 86 23 12 AV1 +0.07 11 AV2 +0.05 9

AV5 +0. 02 7

AV6 +0.02 8

AV7 -0.02 86 25 6

AV1 +0.23 7

AV2 +0.02 7

AV4 +0.03 86 27 86 43 86 53 86 57 86 59 86 61 86 63 86 65 8

AV4 +0.05 8

AV6 +0. 00 6

AV6 +0. 07 7

AV7 +0.07 16 AV6 +0.05 17 AV7 +0.02 9

AV8 +0.05 7

AV6 +0. 02 9

AV3 +0.10 8

AV4 +0.05 11 AV5 +0.07 7

AV2 +0.09 6

AV3 +0.05 5

AV4 +0.08 10 AV5 +0.00 7

AV6 +0.00 9

AV7 +0.07 86 67 7

AV2 +0.10 16 AV3 +0.10 9

AV4 +0.11 86 71 9

AV3 +0.14 86 73 8

AV1 +0.05 14 AV4 +0.06 7

AV3 +0.07 12 AV6 +0.05 7

AV7 +0.07 6

AV8 +0.07 86 75 14 AV4 +0.11 14 AV7 +0.07 86 77 7

AV3 +0.09 8

AV5 +0.12 17 AV6 +0.07 8

AV7 +0.07 86 79 10 AV3 +0.10 8

AV6 +0.07 7

AV7 +0.00 86 81 10 AV2 +0.12 7

AV4 +0.06 17 AV5 +0.02 86 83 9

AV3 +0.07 13 AV4 +0. 05 16 AV5 +0.02 13 AV6 +0.05 16 AV7 +0.05 86 85 17 AV2 +0.05 14 AV5 +0.12 6

AV6 +0.05 8

AV7 +0.05 86 87 7

AV2 +0.12

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 15 AV3 +0.09 14 AV4 +0.05 15 AV5 +0.02 18 AV6 +0.05 16 AV7 +0.02 9

AV8 +0.07 86 89 7

AV2 -0.37 9

AV3 +0.14 16 AV4 +0.05 16 AV5 +0.02 13 AV7 +0.07 86 91 9

AV7 +0.07 8

AV8 +0.05 86 93 11 AV2 +0.09 11 AV3 +0.12 10 AV4 +0.05 16 AV6 +0.05 12 AV7 +0.07 6

AV8 +0.05 86 95 16 AV7 -0.05 16 AV6 -0.05 16 AV5 -0.05 11 AV4 -0.05 13 AV3 +0.02 86 97 13 AV2 +0.02 8

AV1 -0.02 10 AV7 -0.05 16 AV6 -0.05 86 99 8

AV7 -0.05 17 AV6 -0.02 13 AV4 +0.00 15 AV3 -0.02 9

AV2 +0.00 8

AV1 +0.05 86 101 6 AV5 +0.12 10 AV4 -0.09 7

AV3 +0.00 86 103 12 AV6 +0.02 16 AV5 -0.05 9

AV4 -0.05 86 105 8 AV6 -0.05 7

AV4 +0.13 86 107 6 AV4 -0.21 86 109 7 AV7 -0.07 8

AV2 +0.00 86 133 8 AV4 -0.14 87 24 7

AV7 +0.00 87 34 7

AV2 +0.23 87 36 5

AV4 +0.08 87 48 7

AV5 +0.07 87 54 11 AV2 +0.02 87 58 6

AV6 +0.05 87 62 8

AV6 +0.07 87 64 10 AV4 +0.13 13 AV5 +0.02 87 66 11 AV5 +0.02 13 AV6 +0. 02 17 AV7 +0.07 87 68 10 AV2 +0.16 87 70 7

AV1 +0.05 12 AV2 +0.08 17 AV3 +0.02 87 72 15 AV2 +0.05 7

AV3 +0.02 13 AV4 +0.03 8

AV5 +0.02 7

AV7 +0.07 87 74 9

AV4 +0.00 13 AV5 +0.00 8

AV6 +0.05 87 76 11 AV3 +0.07 16 AV6 +0.07 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 87 78 11 AV3 +0.09 12 AV4 +0.03 12 AV5 +0.05 13 AV6 +0. 05 87 80 12 AV3 +0.05 16 AV4 +0.00 8

AV7 +0.02 87 82 6

AV2 +0.14 12 AV3 +0.12 17 AV4 +O.H 87 84 13 AV2 +0.07 19 AV3 +0.07 9

AV6 +0.09 87 86 11 AV3 +0.09 10 AV4 +0.08 13 AV5 +0.07 9

AV6 +0.05 6

AV7 +0.05 87 88 8

AV2 +0.09 11 AV3 +0.12 9

AV4 +0.03 14 AV5 +0. 05 87 90 8

AV3 +0.14 14 AV4 +0.05 18 AV5 +0.05 14 AV6 +0.05 11 AV7 +0.05 87 92 9

AV3 +0.18 12 AV4 +0.08 14 AV5 +0. 05 7

AV7 +0.05 87 94 8

AV2 +0.07 8

AV3 +0.12 7

AV4 +0.11 10 AV5 +0.09 9

AV6 +0.07 87 96 5

AV7 +0.02 13 AV6 -0.02 19 AV5 -0.03 11 AV4 +0. 00 14 AV3 -0.02 13 AV2 +0. 02 7

AV1 -0.02 87 98 18 AVS -0.07 15 AV5 -0.05 7

AV4 -0.05 9

AV2 +0.00 87 100 5 AV7 +0.14 8

AV6 -0.07 6

AV5 -0.08 6

AV4 -0.09 87 102 15 AV3 -0.02 17 AV2 -0.02 87 104 6 AV3 +0.18 87 106 16 AV7 -0.02 87 110 12 AV7 -0.07 7

AV6 -0.07 15 AV5 -0.08 9

AV4 -0.09 87 120 7 AV5 -0.03 87 122 9 AV4 -0.07 87 128 5 AV3 +0.14 87 130 6 AV4 -0.05 88 23 8

AV1 +0.12 7

AV4 +0.10 88 27 6

AV1 +0.05 7

AV4 +0. 05 88 29 8

AV1 +0.22 88 37 8

AV5 +0.05 88 39 8

AV4 +0.08 88 41 8

AV4 +0.03 88 47 7

AV4 +0. 08 L-2019-064 Enclosure Page 70 of 89 Page 11 of 27 ROW COL %TW LOCATION 88 49 7

AV5 +0.05 88 59 7

7 AV3 +0.00 AV4 +0.16 15 AV6 +0.05 10 AV7 +0.07 88 63 7

AV5 +0.05 88 65 9

AV2 +0.09 11 AV5 +0.07 88 69 7

AV5 -0.10 7

AV4 +0.08 88 71 14 AV3 +0.16 8

AV8 +0. 00 88 73 8

AV3 +0.14 19 AV4 +0.08 13 AV5 +0.05 15 AV6 +0.05 88 75 8

AV2 +0.07 7

AV3 +0.17 8

AV5 +0.07 88 88 77 79 11 AV7 +0. 02 8

AV4+0.08 88 81 8

AV2 +0.05 10 AV4 -0.05 12 AV6 +0.07 14 AV7 +0.05 88 83 9

AV3 +0.10 7

AV5 +0.02 88 85 15 AV2 +0.12 17 AV3 +0.12 19 AV4 +0.05 11 AV6 +0.05 18 AV7 +0.05 88 87 9

AV3 +0.07 9

AV4 +0.08 9

AV5 +0. 05 16 AV6 +0.10 16 AV7 +0.05 8

AVS +0.07 88 89 10 AV3 +0.09 8

AV4 +0.08 88 91 6

AV2 +0.09 88 93 8

AV2 +0.09 7

AV3 +0.14 8

AV4 +0.05 9

AV6 +0.07 10 AV7 +0.09 88 95 14 AV8 -0.05 16 AV4 -0.07 12 AV3 -0.05 5

AV2 -0.18 88 97 12 AV7 -0.05 18 AV4 -0.05 12 AV2 +0.00 88 99 8

AV2 -0.02 8

AV1 +0.02 17 AV7 -0.02 16 AV3 -0.05 88 101 5 AV3 -0.09 88 103 17 AV4 -0.05 7

AV2 -0.23 14 AV7 +0.00 88 105 11 AV6 -0.05 10 AV3 +0.00 13 AV2 -0.02 88 107 5 AV7 -0.02 9

AV6 -0. 07 14 AV5 -0.03 6

AV4 -0. 05 7

AV3 -0.02 88 111 7 AV3 -0.18 88 113 5 AV5 -0.24 88 131 5 AV5 -0.05

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 8

AV3 +0.09 88 133 9 89 26 5

89 36 6

89 38 5

89 42 7

89 46 6

89 48 8

89 52 6

89 58 7

AV2 +0. 02 AV1 -0.14 AV4 +0. 08 AV4 +0.13 AV6 +0. 05 AV3 +0.07 AV5 +0. 09 AV2 +0. 02 AV2 +0.14 7

AV3 +0.07 89 60 8

AV3 +0.12 6

AV7 +0.07 89 62 10 AV2 +0.07 13 AV3 +0.00 9

AV4 +0.08 89 64 8

AV5 +0.07 89 66 14 AV4 +0.14 8

AV5 +0.09 10 AV7 +0.07 89 68 9

AV3 +0.07 89 70 89 72 89 74 89 76 8

12 11 17 16 7

7 12 8

17 15 16 8

10 14 16 13 19 6

7 10 7

8 AV4 +0. 05 AV5 +0.02 AV5 +0. 05 AV6 +0.02 AV7 +0.07 AV1 +0. 05 AV2 +0.05 AV3 +0.07 AV4 +0.05 AVS +0.05 AV6 +0.07 AV7 +0.05 AV8 +0.12 AV2 +0.07 AV3 +0.12 AV4 +0. 08 AVS +0. 05 AV6 +0.07 AV3 +0.19 AV4 +0. 08 AVS +0. 02 AV6 +0. 07 AV7 +0.07 89 78 10 AVS +0.05 8

AV7 +0.05 89 80 9

AV2 +0.09 14 AV3 +0.10 9

AV4 +0.03 13 AV5 +0.05 9

AV6 +0.07 89 82 8

AV2 +0.05 17 AV4 +0.05 15 AV7 +0.09 89 84 7

AV7 +0.05 6

AV1 +0.09 13 AV2 +0.09 11 AV3 +0.05 89 86 11 AV2 +0.17 16 AV3 +0.12 17 AV4 +0. 05 19 AVS +0. 05 12 AV6 +0.00 10 AV7 +0.02 89 88 7

AV2 +0.14 10 AV3 +0.14 5

AV4 +0.05 10 AVS +0.07 12 AV6 +0. 07 14 AV7 +0.02 8

AVS +0. 02 89 90 10 AV2 +0.14 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 14 AV3 +0.23 13 AV6 +0.05 6

AV7 +0.05 89 92 6

AV2 +0.09 6

AV3 +0.16 16 AVS +0.05 11 AV7 +0.05 89 94 8

AV2 +0.14 13 AV3 +0.19 7

AV4 +0.08 10 AV6 +0.07 10 AV7 +0.05 89 96 9

AV7 -0.02 8

AV5 +0.00 8

AV4 -0.05 10 AV3 +0. 02 11 AV2 +0.00 8

AV1 +0.02 89 98 8

AV7 -0.02 6

AV6 -0.02 8

AV5 -0.03 89 89 89 89 90 90 90 90 90 90 90 90 17 10 9

100 10 15 12 9

8 104 7 13 1169 128 6 7

29 8

31 6

33 8

37 9

39 5

43 5

51 7

53 6

11 9

AV4 -0.05 AV3 -0.05 AV1 +0.05 AV8 -0.02 AV7 +0.00 AV6 -0.05 AV4 +0.03 AV3 +0.00 AV4 -0.21 AV3 -0.02 AV5 -0.08 AV4 -0.18 AV3 +0.05 AV1 +0.23 AV1 +0.07 AV3 +0.14 AVS +0.05 AV5 +0.05 AV3 +0.05 AV3 +0.07 AV3 +0. 02 AVS +0.05 AV6 +0.00 10 AV7 +0.02 8

AVS +0.02 90 59 8

AV3 +0.05 90 61 8

AV3 +0.07 15 AV5 +0.09 90 63 17 AV5 +0.09 10 AV6 +0.02 8

AV7 +0.12 90 65 12 AV2 +0.07 12 AV3 +0.07 10 AV5 +0. 05 18 AV6 +0. 07 8

AV7 +0.07 90 67 6

AV2 +0.10 6

AV3 +0.10 6

AV4 +0.13 7

AVS +0.09 12 AV6 +0.05 10 AV7 +0. 02 90 69 6

AV3 +0.10 9

AV4 +0.11 9

AVS +0.05 11 AV6 +0.07 90 71 6

AV2 +0.05 9

AV6 +0. 05 15 AV7 +0.05 90 73 9

AV3 +0.07 14 AV4 +0.05 L-2019-064 Enclosure Page 71 of 89 Page 12 of 27 ROW COL %TW LOCATION 18 AV6 +0.05 90 75 6

AV2 +0.05 8

AV3 -0.09 7

AV4 +0.03 7

AV5 +0. 05 90 77 13 AV4 +0.03 90 79 12 AV4 +0.03 13 AV6 +0. 05 9

AV7 +0.02 90 81 15 AV2 +0.07 8

AV3 +0.12 13 AV4 +0.03 90 83 7

AV2 +0.07 11 AV3 +0. 07 19 AV4 +0.05 14 AV6 +0.05 90 85 14 AV2 +0.05 12 AV3 +0.05 19 AV4 -0.02 13 AV8 +0.00 90 87 9

AV3 +0.16 90 89 90 91 90 93 90 95 17 11 8

10 11 8

16 18 9

8 7

6 10 9

8 7

10 9

12 9

15 14 6

AV4 +0.05 AVS +0.05 AV6 +0.24 AV7 +0. 07 AV3 +0.18 AV4 +0.10 AVS +0. 05 AV6 +0. 05 AV7 +0.09 AV2 +0.14 AV2 +0.14 AV3 +0.09 AV4 +0.08 AV2 +0.14 AV3 +0.12 AV4 +0. 05 AV5 +0.02 AV6 +0.02 AV7 +0.07 AV7 -0.05 AV6 -0.02 AVS -0.05 AV4 -0.07 8

AV3 +0.02 7

AV2 -0.16 90 97 16 AVS -0.03 12 AV4 -0.02 17 AV3 +0.02 15 AV2 +0. 02 90 99 12 AV7 -0.05 19 AV6 -0.05 19 AV5 -0.05 6

AV4 -0.07 11 AV3 +0.02 8

AV2 -0.02 90 101 11 AV4 +0.00 9

AV3 +0.00 90 103 8 AV8 -0.05 16 AV7 +0.00 7

AV5 +0.14 17 AV4 -0.07 7

AV3 +0. 02 10 AV2 -0.02 8

AV1 +0.00 90 105 7 AVS -0.03 90 107 14 AV5 -0.03 90 127 5 AV5 +0.05 91 24 6

AV1 -0.14 91 36 7

AV4 +0.10 91 38 7

AV3 +0.05 7

AV5 +0.05

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 91 44 6

AV3 +0.07 91 46 6

AV4 +0.05 6

AV5 +0.02 91 50 AV5 +0.05 10 AV6 +0.12 91 54 8

AV4 +0.08 91 58 8

AV4 +0.05 91 60 12 AV2 +0.09 10 AV4 +0.03 91 62 8

AV3 +0.07 91 64 10 AV5 +0.05 91 66 8

AV1 +0.05 8

AV2 +0.09 15 AV7 +0.05 91 68 9

AV3 +0.07 91 70 8

AV4 +0.08 14 AV5 +0.07 91 72 91 74 91 76 91 78 91 80 7

AV2 +0.07 13 AV4 +0.05 11 AV5 +0.09 9

AV6 +0.05 10 AV3 +0.05 12 AV4 +0.03 14 AV5 +0.02 17 AV6 +0.02 17 AV7 +0.05 9

AVS -0.05 6

AV2 -0.05 6

AV1 -0.07 12 AV6 -0.07 15 AV5 -0.08 15 AV3 +0.00 8

AV2 -0.05 14 AV7 -0.07 17 AV5 -0.08 11 AV4 -0.09 91 82 8

AV4 -0.12 7

AV2 +0.00 91 84 5

AV7 +0.40 10 AV6 +0.02 19 AV5 -0.03 14 AV4 -0.02 10 AV3 -0.02 5

AV2 +0.21 91 86 10 AV7 -0.05 12 AV6 -0.05 17 AV5 -0.05 16 AV4 -0.02 12 AV2 +0.02 91 88 5

AVS +0.40 7

AV7 -0.05 8

AV6 -0.07 16 AV5 -0.05 14 AV4 -0.02 10 AV3 -0.02 5

AV2 +0.48 91 90 15 AV7 -0.02 7

AV6 -0.02 8

AV5 -0.03 14 AV4 -0.05 8

AV3 +0.07 91 92 18 AV4 -0.02 10 AV3 +0.05 10 AV2 +0.02 91 94 9

AV7 -0.05 9

AV6 -0. 02 5

AV5 -0.10 8

AV4 -0.10 8

AV3 +0.00 7

AV2 -0.07 91 96 14 AV7 -0.02 7

AV3 +0.00 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 6

AV2 +0.05 7

AV1 -0.05 91 98 17 AV5 +0.00 11 AV4 +0.00 14 AV3 +0.05 9

AV2 -0.02 12 AV1 +0.00 91 100 16 AV5 +0.07 8

AV6 +0. 05 91 102 5 AV5 +0.02 7

AV7 +0.02 5

AVS +0.02 91 104 10 AV3 +0.19 6

AV5 +0.02 7

AV6 +0.00 91 106 8 AV4 +0.08 91 110 9 AV3 +0.14 91 91 91 91 92 92 92 92 92 92 92 92 92 92 92 8

120 7 124 5 128 5 130 6 25 6

37 6

39 8

43 5

5 45 6

49 8

53 7

57 6

61 10 63 8

65 7

14 AV4 +0.13 AV5 +0.07 AV4 +0.10 AV4 +0. 05 AV4 +0. 05 AV1 -0.18 AV5 +0.05 AV5 +0.05 AV4 -0.14 AV5 -0.11 AV5 +0.02 AV4 +0.08 AV5 +0.00 AV3 +0. 05 AV3 +0.10 AV5 +0.09 AV4 +0.14 AV6 +0. 07 17 AV7 +0.07 92 67 6

AV4 +0.06 92 69 9

AV3 +0.07 9

AV4 +0.06 14 AV6 +0.00 9

AV7 +0.05 92 71 6

8 AV2 +0.05 AV3 +0.07 6

AV6 +0.07 5

AVS +0.05 92 73 8

AV4 +0.09 6

AV7 +0.07 92 75 10 AVS -0.05 17 AV7 -0.09 12 AV6 -0.05 11 AV4 -0.05 6

AV3 -0.02 92 77 7

AV8 +0.00 7

AV3 +0.00 8

AV2 -0.02 92 79 13 AV7 -0.05 92 81 8

AVS -0.05 19 AV6 -0.05 6

AV4 -0.12 10 AV3 -0.07 92 83 8

AV7 -0.14 11 AV6 -0.05 19 AV4 -0.07 16 AV3 +0. 02 8

AV2 +0.02 92 85 16 AV4 -0.02 8

AV3 -0.02 11 AV2 -0.05 4

AV1 +0.39 92 87 11 AV8 +0.00 14 AV7 -0.05 12 AV6 -0.05 L-2019-064 Enclosure Page 72 of 89 Page 13 of 27 ROW COL %TW LOCATION 12 AV4 +0.00 18 AV3 +0.05 10 AV1 +0.00 92 89 5

AV6 -0.07 8

AV4 -0.02 7

AV3 -0.07 5

AV2 +0.32 92 91 7

AV7 -0.07 10 AV6 -0.09 8

AV3 -0.02 92 93 12 AV7 -0.02 12 AV6 -0.05 19 AV5 -0.03 13 AV4 -0.02 6

AV3 +0.00 6

AV2 -0.02 92 95 8

AV7 -0.02 92 92 19 AV6 +0.00 15 AV3 +0.02 10 AV2 +0.02 97 10 AV8 -0.05 13 AV7 -0.05 14 AV5 -0.03 9

AV4 +0. 00 10 AV3 +0. 02 8

AV2 +0.02 99 15 AV8 -0.02 19 AV7 -0.05 12 AV4 -0.02 18 AV2 +0.02 15 AV1 -0.02 101 5 AV1 +0.23 11 AV2 +0.07 8

AV5 +0.12 103 8 AV3 +0.12 18 AV5 +0.09 5

AV2 -0.07 92 107 9 AV3 +0.12 92 92 9

AV4 +0. 08 7

92 109 9 92 117 8 92 121 6 AV7 +0.05 AV5 +0. 07 AV4 +0.08 AV3 +0. 07 7

AV5 +0.09 92 123 7 AV2 +0.07 7

AV5 +0.05 93 24 6

AV1 -0.16 93 26 8

AV1 -0.12 93 30 6

AV1 +0.14 93 40 4

AV3 +0.19 6

AV4 +0.11 93 44 7

AV4 +0.03 93 46 7

AV4 +0.03 93 54 5

AV6 +0.05 93 56 7

AV3 +0.07 93 60 7

AV4 -0.05 93 64 18 AV6 +0.02 10 AV7 +0.05 11 AV4 +0.06 13 AV5 +0.05 93 66 10 AV5 +0.02 8

AV6 +0.05 93 68 8

AV2 +0.10 7

AV3 +0.05 93 70 7

AV4 +0.06 8

AV5 +0.21 93 72 7

AV3 +0.02 10 AV4 +0.05 16 AV6 +0.05 5

AV7 +0.17 93 74 7

AV2 +0.02 11 AV3 +0.02

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 13 AV4 +0.05 17 AV5 +0.02 93 76 14 AV6 -0.05 93 78 7

AV7 -0.07 15 AV6 -0.05 19 AV5 -0.03 93 80 9

AV7 -0.02 19 AV6 -0.05 13 AV5 -0.08 8

AV4 -0.02 11 AV3 +0.00 93 82 19 AV6 -0.05 8

AV4 -0.07 5

AV3 +0.00 6

AV2 +0.00 93 84 10 AVB +0.02 18 AV7 -0.07 15 AV3 -0.05 11 AV2 +0.02 93 86 17 AV3 -0.02 7

AV2 -0.16 93 88 11 AV7 -0.05 18 AV6 -0.07 16 AV5 -0.03 13 AV3 +0.00 10 AV2 -0.02 93 90 6

AV7 -0.02 12 AV5 -0.03 5

AV4 +0.13 5

AV3 -0.12 6

AV2 -0.02 93 92 13 AV8 -0.02 8

AV6 -0.09 19 AV5 -0.03 6

AV4 -0.21 5

AV3 -0.05 10 AV2 +0.00 93 94 19 AV7 -0.02 16 AV3 +0.05 8

AV2 +0.00 5

AV1 +0. 41 93 96 6

AV4 -0.05 6

AV3 -0.05 93 98 5

AVB +0.30 13 AV3 -0.02 6

AV2 -0.05 93 100 8 AV2 +0.07 12 AV3 +0.05 12 AV5 +0.05 8

AV6 +0. 05 16 AV7 +0.09 93 102 8 AV4 +0.03 10 AV5 +0.02 93 104 16 AV3 +0.14 14 AV4 +0.10 11 AV5 +0.09 7

AV6 +0.05 93 106 7 AV4 +0.05 93 112 7 AV4 +0.08 93 116 6 AV2 +0.11 93 128 5 AV4 +0.08 6

AV5 +0.05 93 134 5 AV8 -0.14 94 25 5

AV1 -0.12 94 39 6

AV5 +0.00 94 45 6

AV4 +0.16 94 47 7

AV2 +0.05 94 49 8

AV4 +0.10 94 53 7

AV6 +0.12 94 55 6

AV4 +0.15 7

94 59 9

AV5 +0.00 AV3 +0.10 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 6

AV7 +0.07 94 65 6

AV2 +0.07 7

AV5 +0.02 8

AV6 +0. 02 94 67 18 AV6 +0.05 16 AV7 +0.05 19 AV4 +0.11 16 AV5 +0.05 94 69 6

AV1 +0.05 18 AV3 +0.19 7

AV6 +0. 07 94 71 7

AV1 +0.09 8

AV2 +0.07 8

AV3 +0.12 12 AV5 +0.12 16 AV6 +0.07 94 73 12 AV1 +0.09 6

AV2 +0.16 9

AV4 +0.17 94 75 7

AV4 +0.03 9

AV3 +0.05 94 77 15 AV7 -0.07 19 AV5 -0.08 10 AV4 -0.05 7

AV2 -0.05 94 79 13 AV7 -0.09 19 AV6 +0.00 13 AV5 +0.00 7

AV4 -0.05 7

AV3 -0.07 8

AV2 -0.02 6

AV1 -0.07 94 81 19 AV5 -0.05 17 AV3 -0.02 94 83 8

AVB -0.02 15 AV7 -0.07 9

AV2 +0.00 4

AV1 +0.11 94 85 13 AV7 -0.05 14 AV6 -0.05 8

AV1 +0. 02 94 87 14 AV7 -0.05 15 AV6 -0.02 10 AV2 +0.05 94 89 7

AV7 +0.00 8

AVB -0.05 9

AV6 -0.05 11 AV5 +0.00 16 AV4 +0.00 16 AV3 +0.05 12 AV2 +0.02 6

AV1 +0. 05 94 91 14 AV7 +0.00 94 93 7

AV7 +0.00 16 AV6 -0.05 14 AV5 +0. 00 17 AV4 -0.02 10 AV3 -0.02 8

AV2 -0.02 7

AV1 -0.05 94 95 13 AV5 +0.00 94 97 7

AVB -0.05 10 AV6 -0.02 8

AV5 -0.05 5

AV4 -0.07 9

AV3 +0.00 13 AV2 +0.02 94 99 8

AVB +0.02 7

AV7 -0.05 18 AV6 -0.05 16 AV3 +0.02 7

AV2 +0.00 L-2019-064 Enclosure Page 73 of 89 Page 14 of 27 ROW COL %TW LOCATION 7

AV1 -0.02 94 101 6 AV3 +0.12 9

AV4 +0.11 94 103 9 AV3 +0.10 10 AV6 +0.05 94 105 9 AV2 +0.05 10 AV3 +0.10 94 115 7 AV3 +0.07 7

AV4 +0.11 94 119 7 AV3 +0.07 9

AV4 +0.10 7

AV5 +0. 02 94 123 7 AV4 +0.03 94 125 14 AV2 +0.09 95 28 6

AV1 -0.14 95 42 8

AVB +0.09 95 46 8

AV4 +0.05 95 48 7

AV5 +0.02 95 50 7

AV4 +0.08 6

AV5 +0.07 95 54 10 AV3 +0.02 95 58 8

AV3 +0.05 8

AV4 +0.08 95 60 8

AV4 +0.03 95 62 8

AV4 +0.03 9

AV5 +0.00 13 AV6 +0. 07 9

AV7 +0.05 95 64 8

AV3 +0.12 8

AV4 +0.11 17 AV6 +0.05 95 66 7

AV1 +0.12 8

AV2 +0.10 10 AV3 +0.12 7

AV5 +0.05 95 68 8

AV3 +0.02 5

AV5 +0.07 95 70 11 AV4 +0.09 6

AV5 +0.19 8

AV6 +0.07 6

AV7 +0.07 95 72 5

AV1 +0.16 17 AV3 +0.10 14 AV4 +0.11 17 AV5 +0.09 10 AV6 +0.05 95 74 7

AV3 +0.02 10 AV6 +0.05 8

AV7 +0.05 95 76 12 AV7 -0.07 13 AV6 -0.05 16 AV5 -0.05 8

AV4 -0.07 95 78 13 AV7 -0.05 18 AV6 -0.02 13 AV4 -0.05 95 80 8

AV3 +0.02 95 82 8

AV7 -0.02 17 AV5 -0.08 9

AV3 +0.00 9

AV2 +0.07 95 84 12 AVB +0.02 11 AV6 +0.02 16 AV2 +0.02 8

AV1 -0.02 95 86 7

AV8 -0.07 19 AV6 +0.00 16 AV2 +0.02 95 88 8

AVB -0.05 18 AV6 +0. 00 13 AV5 +0.00 11 AV3 -0.02

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 12 AV2 -0.02 95 90 10 AV7 -0.05 14 AV6 -0.02 19 AV5 -0.03 14 AV4 -0.05 5

AV3 -0.05 4

AV2 -0.02 95 92 10 AV7 -0.02 8

AV6 +0.05 8

AV4 -0.05 8

AV3 +0.05 9

AV2 +0.05 95 94 17 AV7 -0.03 13 AV6 -0.05 16 AV5 -0.08 10 AV4 -0.07 11 AV3 +0.00 17 AV2 -0.05 11 AV1 -0.05 95 96 16 AV7 -0.02 15 AV3 +0.02 9

AV2 +0.00 95 98 5

AV6 +0.50 6

AV5 +0.47 6

AV4 -0.23 19 AV3 +0.02 7

AV2 -0.02 10 AV7 +0.00 95 100 12 AV1 +0.12 17 AV2 +0.12 19 AV3 +0.15 17 AV5 +0.09 11 AV6 +0.07 9

AV7 +0.11 95 102 11 AV3 +0.07 9

AV4 +0.05 95 104 8 AV3 +0.15 6

AV4 +0.03 18 AV5 +0.05 19 AV6 +0.05 15 AV8 +0.05 95 106 8 AV5 +0.09 95 110 6 AV2 +0.07 8

AV3 +0.07 95 112 5 AV4 +0.08 95 118 7 AV5 +0.07 95 120 5 AV4 -0.10 5

AV5 +0.10 96 39 5

AV4 +0.08 96 41 7

AV5 +0.05 96 43 5

AV4 -0.07 96 47 7

AV3 +0.02 96 49 7

AV6 +0.07 96 53 8

AV3 +0.00 96 57 96 59 96 61 96 65 96 67 96 69 96 71 96 73 7

AV4 +0.08 7

AV6 +0.05 8

AV4 +0.08 11 AV4 +0.16 9

AV1 +0. 05 7

AV4 +0.16 8

AV5 +0.07 9

AV6 +0.12 8

AV4 +0. 08 6

AV4 +0.05 7

AV3 +0.05 8

AV5 +0.02 8

AV2 +0.10 17 AV3 +0.02 9

AV5 +0.09 18 AV6 +0.07 16 AV8 +0.05 15 AV4 +0.03 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 9

AV5 +0.05 96 75 6

AV7 -0.07 9

AV6 -0.05 9

AV5 -0.03 7

AV4 -0.07 7

AV3 -0.05 96 77 11 AV8 +0.00 9

AV7 -0.05 16 AV6 -0.02 11 AV4 -0.05 18 AV2 -0.04 96 79 17 AV7 -0.07 11 AV3 -0.02 96 81 9

AV8 -0.05 14 AV7 -0.02 5

AV6 -0.02 8

AV5 +0.00 7

AV4 -0.12 9

AV3 +0. 02 8

AV2 -0.02 96 83 10 AV8 -0.05 13 AV7 -0.05 12 AV6 -0.05 18 AV5 -0.05 18 AV3 -0.05 11 AV2 -0.05 10 AV1 -0.05 96 87 14 AV7 -0.05 16 AV5 -0.05 18 AV4 -0.07 17 AV3 -0.02 12 AV2 -0.02 5

AV1 -0.05 96 89 8

AV8 -0.05 12 AV7 -0.05 19 AV5 -0.05 8

AV4 -0.10 8

96 91 7

AV3 -0.02 AV7 -0.07 17 AV6 -0.07 5

AV5 +0.28 9

AV4 -0.07 8

AV3 -0.05 7

AV2 +0.00 96 93 5

AV8 +0.49 7

AV4 -0.05 13 AV3 -0.05 9

96 95 7

8 9

8 5

6 7

AV2 -0.02 AV8 -0.05 AV7 -0.02 AV6 +0. 05 AV5 +0.02 AV4 +0.16 AV3 +0.02 AV2 -0.05 96 97 7

AV8 -0.02 13 AV4 -0.05 14 AV3 -0.02 9

AV2 +0.00 96 99 12 AV4 -0.05 4

AV5 +0.09 9

AV3 +0.00 96 101 5 AV3 +0.05 8

AV4 +0.03 5

AV5 +0.07 96 103 12 AV4 +0.03 10 AV5 +0.02 96 105 13 AV2 +0.07 9

AV4 +0.13 96 107 6 AV3 +0.05 15 AV6 +0.05 16 AV7 +0.02 L-2019-064 Enclosure Page 74 of 89 Page 15 of 27 ROW COL %TW LOCATION 96 109 9 AV5 +0.05 6

AV7 +0.02 96 115 6 AV4 +0.03 96 117 5 AV3 +0.09 97 34 7

AV3 +0.21 97 36 6

AV5 +0.07 97 42 5

AV6 +0.23 4

AV5 +0.17 97 46 6

AV5 +0.07 97 48 8

AV5 +0.09 97 50 10 AV4 +0.13 97 54 10 AV3 +0.10 97 56 6

AV3 +0.00 7

AV6 +0.07 97 58 6

AV3 +0.10 8

AV4 +0. 03 12 AV5 +0.07 6

AV6 +0.19 97 62 8

AV3 +0.07 7

AV4 +0.11 97 64 9

AV6 +0.02 7

AV8 +0.07 97 66 18 AV8 +0.07 97 68 8

AV3 +0.07 7

AV4 +0. 08 12 AV5 +0.00 97 70 15 AV2 +0.12 13 AV3 +0.07 9

AV4 +0.05 10 AV5 +0.05 97 72 7

AV2 +0.12 9

AV3 +0.12 8

AV4 +0.05 7

AV5 +0.09 13 AV6 +0. 07 8

AV7 +0.05 97 78 14 AV7 -0.05 11 AV6 -0.05 16 AV5 -0.03 10 AV4 -0.07 12 AV3 +0.00 97 80 7

AV7 -0.09 9

AV5 -0.03 9

AV3 -0.05 97 82 9

AV7 -0.02 15 AV6 -0.05 15 AV5 -0.08 10 AV4 +0.00 9

AV3 -0.05 9

AV2 +0. 02 97 84 12 AV7 -0.05 18 AV4 -0.07 13 AV3 -0.07 14 AV2 -0.05 97 86 8

AV8 -0.02 19 AV6 -0.07 13 AV2 -0.02 97 97 97 88 90 92 10 AV7 -0.07 15 AV6 -0.07 15 AV5 -0.05 11 AV4 -0.02 7

AV3 -0.18 6

AV2 -0.02 6

AV1 -0.02 16 AV7 -0.02 17 AV6 -0.02 11 AV5 -0.03 7

AV4 -0.02 17 AV3 +0.00 9

AV2 +0.02 9

AV8 -0.02 15 AV7 -0.05

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 18 AV6 -0.05 15 AV2 +0. 00 97 94 9

AV7 -0.05 15 AV6 -0.02 4

AV5 +0.17 7

AV4 -0.05 11 AV3 -0.05 7

AV2 -0.05 5

AV1 -0.16 97 96 19 AV7 -0.05 17 AV5 -0.03 8

AV4 -0. 02 13 AV3 +0.02 9

AV2 +0.07 9

AVl -0.02 97 98 17 AV7 -0.05 19 AV6 -0.02 17 AV4 -0.02 13 AV3 +0.02 8

AV2 +0.00 97 100 8 AV4 -0.05 19 AV5 +0.07 17 AV6 +0.05 97 102 5 AVl +0.09 5

AV4 -0.10 7

AV5 +0.05 97 104 15 AV3 +0.12 16 AV6 +0.07 12 AV7 +0.05 97 106 8 AV3 +0.02 8

AV6 +0.05 5

AV7 +0.02 97 114 7 AV4 +0.10 97 118 5 AV4 -0.07 6

AV5 +0.05 98 27 7

AVl -0.14 98 29 6

AVl -0.11 7

AV2 +0.05 7

AVS +0.04 98 39 7

AV5 +0.05 98 43 5

AV4 +0.05 98 49 6

AV5 +0.05 98 51 10 AV4 +0.11 98 53 7

AV3 +0.07 10 AV6 +0.07 98 57 6

AV2 +0.10 8

AV4 +0.00 98 59 6

AV5 +0.09 98 61 8

AV4 +0.11 98 63 7

AV4 +0.03 7

AV7 +0.10 98 65 11 AV6 +0.05 8

AV7 +0. 07 98 67 10 AVl +0.09 12 AV2 +0.09 8

AV4 +0.16 98 69 9

AV2 +0.14 6

7 6

AV3 +0.15 AV4 -0.10 AV7 +0.07 98 71 7

AV3 +0.05 5

AV4 +0.03 6

AV6 +0.16 98 73 6

AV5 +0.07 98 75 16 AVS -0.02 12 AV6 -0. 02 7

AV4 -0.02 13 AV3 +0.00 5

AV2 -0.09 98 77 7

AV8 +0.00 8

AV7 -0. 02 7

AV6 -0.05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 16 AV5 +0.00 8

AV4 -0.02 7

98 79 7

AV3 +0.00 AV7 -0.02 14 AV6 +0.00 7

AV5 +0.00 7

AV4 -0.02 98 81 12 AV3 +0.00 10 AV5 -0.03 19 AV4 -0.05 98 83 7

AV7 -0.02 6

AV6 -0.02 18 AV5 -0.05 19 AV4 -0.05 17 AV3 +0.00 10 AV2 -0.02 98 85 6

AVS -0.07 17 AV6 -0.02 13 AV5 -0.03 6

AV1 -0.05 98 87 13 AV8 -0.05 15 AV4 -0.05 10 AV3 +0.00 98 89 8

AV6 -0.07 13 AV5 -0.03 13 AV4 -0.05 7

AV3 -0.23 98 91 8

AV6 +0.02 15 AV5 -0.03 12 AV3 +0.00 7

AV2 +0.00 98 93 7

AV6 -0.02 14 AV5 +0.00 17 AV4 +0.00 8

AV3 +0.00 7

AV2 +0.05 6

AV1 +0.02 98 95 17 AV8 -0.02 7

AV5 -0.08 7

AV3 +0.02 9

AV2 -0.02 6

AV1 +0.00 98 97 8

AV8 -0.05 10 AV6 -0.02 18 AV5 +0.00 12 AV3 -0.02 17 AV2 +0.00 98 99 4

AV8 -0.02 9

AV4 -0.02 7

AV3 -0.05 5

AV2 -0.02 98 101 7 AV2 +0.09 6

AV3 +0.05 7

AV6 +0. 05 5

AV7 +0.07 98 103 11 AV2 +0.16 19 AV4 +0.10 18 AV5 +0.09 7

98 105 9 AV7 +0.02 AV3 +0.07 6

AV6 +0.02 98 107 11 AV5 +0.05 17 AV7 +0.02 98 109 9 AV3 +0.00 7

AV4 +0.16 98 111 7 AV5 +0.07 98 121 6 AV3 +0.09 6

AV4 +0.18 98 129 6 AV2 +0.09 5

AV3 +0.21 98 141 5 AV3 +0.07 99 30 6

AVl -0.14 L-2019-064 Enclosure Page 75 of 89 Page 16 of 27 ROW COL %TW LOCATION 99 32 6

AVl +0.19 99 38 7

99 42 6

99 44 5

AV2 +0.10 AV3 +0.17 AV4 -0.14 99 46 7

AV5 +0.07 8

AV6 +0.21 99 48 8

AV3 +0.02 99 50 7

AV2 +0.07 8

AV4 +0.13 99 52 7

AV3 +0.12 9

AV4 +0.13 99 54 6

AV3 +0.10 9

AV6 +0.07 99 56 18 AV3 +0.07 9

AV4 +0.11 99 58 10 AV3 +0.05 99 60 9

AV4 -0.02 99 62 7

AV4 +0.16 99 64 7

AV4 +0.05 16 AV5 +0.07 13 AVS +0.07 99 66 8

AV2 +0.12 10 AV3 +0.12 8

AV7 +0.09 99 68 9

AV2 +0.07 10 AV3 +0.10 9

AV4 +0.09 99 70 8

AV4 +0.03 7

AV5 +0.21 99 72 8

AV3 +0.00 12 AV5 +0.09 13 AV6 +0.02 7

AV7 +0. 05 99 74 14 AV3 +0.05 15 AV4 +0.11 14 AV7 +0.05 99 76 8

AV7 -0.07 12 AV5 +0.00 14 AV4 -0.07 15 AV3 -0.05 99 78 14 AV7 -0.05 12 AV6 -0.02 12 AV5 +0.16 7

AV4 -0.02 11 AV3 -0.02 99 80 12 AV7 -0.07 9

AV6 -0.05 17 AV4 +0.00 8

AV2 +0.00 99 82 8

AV7 -0.09 10 AV6 -0.09 5

AV2 -0.09 99 84 8

AVS +0.02 10 AV7 -0.07 17 AV3 -0.02 17 AV2 +0.00 9

AVl -0.05 99 86 11 AV8 -0.02 14 AV5 -0.03 9

AVl +0.05 99 88 10 AV7 -0.05 15 AV6 -0.09 17 AV5 -0.05 11 AV4 -0.02 10 AV3 -0.02 9

AV2 +0.00 99 90 6

AVS -0.05 9

AV7 -0.02 10 AV6 -0.05 7

AV5 -0.03 7

AV4 -0.19 6

AV3 -0.21

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 99 92 19 AV7 +0.02 8

AV1 +0.02 99 94 8

AV7 -0.02 6

AV6 +0.44 9

AV4 -0.02 11 AV3 +0. 02 11 AV2 +0.00 5

AV1 -0.02 99 96 5

AV7 -0.02 13 AV3 -0.05 5

AV1 +0.18 99 98 14 AV4 +0.03 8

AV2 +0.02 7

AV1 +0.02 99 100 8 AV3 +0.07 10 AV5 +0.05 99 102 8 AV1 +0.05 8

AV2 +0.09 6

AV3 +0.07 14 AV4 +0.03 13 AV5 +0.02 99 104 7 AV2 +0.12 6

AV3 +0.07 6

AV5 +0.02 99 108 17 AV3 +0.07 10 AV4 +0.13 6

AV5 +0.05 99 110 12 AV4 +0.13 99 116 5 AV4 +0.26 99 120 5 AV5 +0.09 99 124 5 AV1 +0.05 6

AV3 +0.12 6

AV4 +0.08 99 128 6 AV6 +0.07 99 132 8 AV5 +0.12 100 31 5

AV2 +0.12 5

AV5 +0.07 100 45 5

AV5 +0.13 100 47 7

AV4 +0.08 100 49 8

AV4 +0.08 7

AV5 +0.10 100 55 7

AV3 +0.10 100 57 6

AV2 +0.09 9

AV4 +0.11 7

AV5 +0.05 100 59 8

AV5 +0.12 100 63 7

AV4 +0.03 15 AV7 +0.09 100 65 100 67 100 71 100 73 100 75 100 77 100 79 17 AV3 +0.05 9

AV4 +0.08 7

AV5 +0.05 14 AV6 +0.02 15 AV7 +0.07 8

AV3 +0.02 11 AV2 +0. 07 12 AV3 +0.07 8

AV4 +0.10 9

AV5 +0.05 11 AV6 +0. 07 19 AV7 +0.05 11 AV8 +0. 05 6

AV1 +0. 05 6

AV3 -0.18 12 AV4 -0.05 16 AV7 -0.09 16 AV6 -0.02 11 AV5 -0.05 100 81 10 AV6 -0.05 13 AV4 +0. 00 14 AV3 +0.02 10 AV2 +0.02 100 85 7

AV5 +0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 18 AV3 -0.05 12 AV2 +0.00 5

AV1 +0.13 100 87 17 AV7 -0.05 16 AV4 -0.05 7

AV3 -0.05 100 89 6

AV7 +0.02 11 AV6 -0.02 16 AV5 -0.05 16 AV4 +0.00 11 AV3 +0.02 100 91 15 AV7 -0.02 16 AV6 -0.05 19 AV5 -0.08 9

AV4 -0.07 100 93 7

AV6 -0.02 12 AV4 -0.02 5

AV3 -0.23 5

AV2 +0. 02 100 95 13 AV7 +0.00 4

AV6 -0. 38 7

AV5 -0.03 6

AV4 -0.26 6

AV3 +0.02 8

AV2 -0.05 100 97 7

AV7 -0.05 6

AV6 +0.00 6

AV5 -0.05 5

AV4 +0.00 12 AV3 +0.02 14 AV2 +0.02 100 99 6

AV6 -0.28 18 AV4 -0.02 10 AV3 +0.02 7

AV2 -0.02 100 101 7 AV3 +0.10 8

AV5 +0.07 8

AV6 +0.07 6

AV7 +0.07 100 103 13 AV2 +0.12 18 AV3 +0.07 15 AV4 +0.10 14 AV5 +0.05 10 AV6 +0.14 100 105 8 AV2 +0.12 7

AV6 +0.05 100 135 8 AV4 +0.05 101 30 11 AV1 -0.16 7

AV2 +0.07 101 46 7

AV5 +0.02 10 AV6 +0.24 101 48 8

AV4 +0.05 7

AV5 +0.05 101 50 8

AV3 +0.12 7

AV4 +0.13 101 52 10 AV4 +0.16 101 54 7

AV3 +0.05 7

AV4 +0.00 101 56 6

AV4 -0.12 101 58 7

AV5 +0.05 101 60 9

AV4 +0.05 101 62 6

AV4 +0.11 101 64 6

AV3 +0.29 7

AV4 +0.08 9

AV5 +0.07 19 AV6 +0.05 19 AV7 +0.09 9

AV8 +0.07 101 66 19 AV4 +0.11 18 AV6 +0.02 7

AV7 +0.14 101 70 7

AV6 +0.09 L-2019-064 Enclosure Page 76 of 89 Page 17 of 27 ROW COL %TW LOCATION 8

AV5 +0.09 101 72 6

AV3 +0.07 8

AV5 +0.23 101 74 7

AV1 +0.07 7

AV2 +0.05 14 AV4 +0.03 12 AV6 +0.07 101 76 11 AV3 -0.05 101 78 8

AV5 +0.14 101 80 7

AV5 -0.03 11 AV4 -0.02 7

AV2 +0.02 101 86 19 AV6 -0.09 7

AV3 -0.05 12 AV2 +0.00 101 88 7

AV7 -0.05 10 AV6 -0.02 7

AV5 -0.03 6

AV4 +0.11 7

AV3 -0.05 4

AV2 -0.22 101 90 16 AV8 -0.05 15 AV6 -0.02 15 AV5 +0.00 8

AV4 -0.02 8

AV3 +0.05 8

AV2 +0.00 101 92 9

AV7 -0.26 10 AV6 +0. 00 19 AV5 -0.08 8

AV4 -0.07 12 AV3 -0.05 10 AV2 -0.05 101 94 6

AV7 -0.05 8

AV6 -0.05 11 AV4 -0.07 7

AV3 -0.02 5

AV2 -0.05 101 96 8

AV7 +0.00 7

AV5 -0.03 10 AV4 +0.00 18 AV3 +0.05 14 AV2 +0.02 101 98 9

AV6 -0.02 12 AV5 +0.00 18 AV2 +0.00 11 AV1 -0.02 8

AV8 -0.02 101 100 8 13 101 104 9 8

101 106 6 101 110 8 101 112 6 12 101 118 7 101 140 6 7

8 102 31 6

5 8

102 47 8

7 AV2 +0.10 AV4 +0.08 AV3 +0.10 AV6 +0. 02 AV2 +0.07 AV5 +0. 05 AV2 +0.05 AV3 +0.09 AV4 -0.10 AV2 +0.07 AV6 +0.07 AV7 +0.07 AV2 +0.26 AV3 +0.17 AV6 +0.02 AV4 -0.02 AV5 +0.05 11 AV6 +0.05 102 51 7

102 65 8

9 AV4 +0.16 AV2 +0.09 AV4 +0.06 102 71 10 AV6 +0.05 102 73 14 AV5 +0.07 102 75 14 AV8 +0.00

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVE Wear 1-19%

ROW COL %TW LOCATION 10 AV3 -0.02 7

AV2 -0.05 5

AV1 -0.05 102 77 9

AV4 -0.12 13 AV7 -0.07 10 AV6 -0.07 13 AV5 -0.05 102 79 5

9 AV6 +0.28 AV4 -0.07 6

AV3 -0.21 102 81 16 AV7 -0.07 19 AV3 +0.00 6

AV2 -0.02 102 83 8

AV3 -0.09 102 85 102 87 102 89 102 91 102 93 102 95 5

AV2 -0.04 5

AVB +0.36 5

AVB -0.23 14 AV5 -0.03 17 AV4 -0.02 18 AV2 -0.02 14 AV1 -0.02 6

AV8 -0.02 17 AV4 -0.07 12 AV3 -0.05 18 AV2 -0.02 10 AV1 -0.02 17 AV7 -0.02 8

AV1 -0.05 11 AV4 -0.09 15 AV3 -0.02 13 AV2 +0.00 7

AV7 -0.07 9

AV5 -0.03 12 AV4 -0.05 9

AV2 +0.02 7

AV1 +0.05 9

AV4 -0.02 7

AV3 +0.02 9

AV2 -0.05 7

8 AVB +0.00 AV7 -0.05 16 AV6 -0.05 7

AV5 -0.10 102 97 16 AV8 -0.05 18 AV7 -0.07 16 AV3 -0.05 14 AV2 +0.00 10 AV1 -0.02 102 99 9

AV4 +0.00 102 109 12 AV2 +0.05 13 AV3 +0.05 7

AV5 +0.09 102 113 6 AV5 +0.07 102 115 6 102 119 8 7

103 44 9

103 48 7

103 52 6

103 54 6

103 56 7

6 6

103 58 5

AV4 +0.08 AV4 +0.06 AV5 +0.02 AV5 +0.09 AV5 +0.05 AV3 +0.12 AV3 +0.12 AV4 +0.11 AV5 +0.09 AV6 +0.19 AV6 +0.16 103 60 6

AV4 -0.07 103 64 8

AV4 +0.05 103 66 7

AV2 +0.05 9

AV4 +0.11 5

AV6 +0.05 103 70 6

AV5 +0.09 103 72 7

AV3 +0.02 9

AV4 +0.03 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 7

AV5 +0.26 10 AV6 +0.07 103 74 10 AV3 +0.10 7

AV4 +0.05 11 AV5 +0.07 13 AV6 +0.07 11 AV7 +0.05 103 76 13 AV6 -0.02 8

AV5 -0.03 8

AV4 -0.07 6

AV3 +0.00 103 78 8

AV5 +0.12 103 80 7

AV5 -0.08 6

AV1 -0.07 103 82 9

AV5 -0.10 103 84 103 86 103 88 103 90 103 92 7

AV3 +0.00 9

AVB +0.00 19 AV4 -0.07 17 AV2 +0.00 8

AV1 +0.00 14 AV7 -0.05 18 AV6 +0.00 10 AV3 +0.00 18 AV2 -0.02 16 AVB -0.05 16 AV7 -0.07 17 AV6 -0.02 12 AV5 -0.05 8

AV4 -0.02 11 AV3 +0.00 9

AVB -0.05 12 AV6 -0.07 11 AV5 -0.08 10 AV3 -0.02 9

AV2 +0.00 9

AV1 +0.00 15 AVB +0.02 15 AV7 -0.07 15 AV6 -0.07 17 AV3 -0.02 103 94 8

AV5 -0.05 18 AV4 -0.05 14 AV3 +0.02 6

AV2 -0.16 103 96 7

AV7 +0.00 5

AV6 +0.45 5

AV5 +0.16 15 AV4 -0.07 12 AV3 -0.05 103 98 10 AV7 -0.07 11 AV5 -0.03 8

AV4 -0.05 5

AV2 +0.21 103 100 11 AV5 +0.07 10 AV6 +0.05 10 AV7 +0.09 103 104 5 AV4 -0.10 103 110 8 AV5 +0.07 103 120 8 AV4 +0.18 103 124 7 AV5 +0.05 103 126 6 AV4 +0.05 104 45 6

AV6 +0.07 104 49 7

AV3 +0.10 104 55 7

AV4 +0.10 7

AV5 +0.07 104 59 7

AV4 +0.11 104 61 7

AV3 +0.05 7

AV4 +0.11 104 63 7

AV4 +0.05 8

AV5 +0.05 6

AV6 +0.02 104 71 6

AV2 -0.07 L-2019-064 Enclosure Page 77 of 89 Page 18 of 27 ROW COL %TW LOCATION 5

AV3 +0.05 5

AV7 +0.05 104 73 8

AV2 +0.07 8

AV3 +0.13 9

AV4 +0.08 104 77 14 AV7 -0.05 10 AV6 -0.05 7

AV5 -0.03 11 AV4 -0.10 10 AV3 -0.02 104 79 6

AV3 -0.09 6

AV2 -0.02 104 81 11 AV7 -0.05 12 AV6 -0.05 14 AV5 -0.05 7

AV4 -0.07 16 AV3 -0.05 104 83 104 87 104 89 104 91 104 93 104 95 15 AVB -0.07 8

AV7 -0.21 7

AV3 -0.07 7

AV7 -0. 05 11 AV6 +0.05 16 AV4 -0.05 8

AV3 -0.23 7

AV2 -0. 07 5

AV1 -0.21 12 AV7 -0.05 8

AV6 -0.05 10 AV5 -0.03 8

AV4 -0.05 8

AV3 +0.00 7

AVB -0.02 12 AV6 -0.05 13 AV2 -0.02 5

AV1 +0.39 9

AV3 +0. 00 7

AV7 +0.12 5

AV6 -0.19 11 AV5 -0.03 6

AV4 -0.21 AV3 -0.02 14 AV2 +0. 00 6

AV1 +0.00 104 97 10 AV6 -0.02 19 AV5 -0.08 15 AV3 +0.00 11 AV2 +0.05 104 99 7

AV7 -0.07 8

AV6 -0.02 6

AV5 -0.05 7

AV4 +0. 00 18 AV3 +0.02 10 AV2 +0.00 7

104 105 7 104 107 7 104 109 5 104 121 7 104 127 7 104 133 7 105 38 5

105 54 8

7 11 AV1 +0.02 AV4 +0.13 AV4 +0. 08 AV4 +0.05 AV4 +0. 03 AV5 +0. 09 AV7 +0. 09 AV6 +0.05 AV3 +0.05 AV4 +0.06 AV5 +0.07 105 58 6

AV3 +0.07 6

AV4 +0. 05 105 64 7

AV5 +0.07 105 70 9

AV6 +0.07 105 72 7

AV1 +0.07 19 AV2 +0.09 13 AV5 +0. 07 11 AV6 +0.09

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVE Wear l-19%

ROW COL %TW LOCATION 105 74 9

AV3 +0.05 8

AV4 +0.03 15 AV6 +0.07 10 AV7 +0.05 105 76 7

AV4 -0.05 105 78 13 AV5 +0.00 7

AV4 -0.05 8

AV3 -0.02 11 AV2 +0. 00 105 80 9

AV6 -0.05 5

AV5 -0.03 7

AV2 -0.02 105 82 8

AV7 -0.02 12 AV6 -0.02 10 AV5 -0.08 12 AV4 -0.05 18 AV3 -0.02 105 86 12 AV8 -0.05 10 AV3 -0.05 15 AV2 -0.07 105 88 8

AV5 -0.05 8

AV4 -0.02 15 AV3 +0.00 12 AV2 +0.02 10 AV1 +0.02 105 90 6

AV8 -0.05 19 AV7 -0.05 7

AV6 +0.12 15 AV5 -0.03 6

AV4 -0.05 6

AV3 +0.14 5

AV2 -0.18 105 92 6

AV7 -0.23 8

AV6 +0.02 9

AV3 -0.02 5

AV2 -0.16 5

AV1 +0.27 105 94 6

AV7 -0.05 9

AV6 -0.02 8

AV5 -0.05 10 AV4 -0.05 9

AV3 -0.02 7

AV2 +0.02 105 96 6

AV6 -0.02 6

AV4 -0.16 11 AV3 -0.02 14 AV2 -0.02 8

AV1 +0.00 105 98 6

AV7 -0.07 10 AV5 +0.00 9

AV4 -0.02 15 AV3 +0.00 7

AV2 +0.00 4

AV1 +0.18 105 100 9 AV4 +0.16 8

AV6 +0.07 8

AV7 +0.09 105 112 12 AV3 +0.05 5

AV5 +0.05 106 33 11 AV6 +0.07 5

AV7 +0.26 106 41 9

AV6 +0.10 106 43 6

AV5 +0.02 106 53 6

AV1 +0.07 11 AV2 +0.17 8

AV3 +0.10 8

AV4 +0.11 9

AV5 +0.07 106 55 9

AV4 +0.08 7

AV5 +0.02 106 57 9

AV4 +0.08 106 59 9

AV5 +0.07 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 106 61 7

AV3 +0.07 7

AV4 +0.14 8

AV5 +0.02 106 63 7

AV3 +0. 05 10 AV5 +0. 05 106 65 8

AV6 +0.05 106 67 6

AV3 +0.10 6

AV4 +0.11 106 71 8

AV3 +0.10 11 AV4 +0.06 9

AV5 +0.02 106 73 6

AV3 +0.05 8

AV4 +0. 03 7

AV5 +0. 02 8

AV6 +0.07 106 75 6

AV4 -0.17 10 AV3 -0.07 6

AV2 -0.16 106 77 7

AV5 -0.03 6

AV3 -0.05 106 81 15 AV7 -0.05 12 AV6 -0.07 13 AV5 -0.08 14 AV4 -0.05 7

AV3 -0.07 106 83 15 AV5 -0.05 19 AV3 -0.05 6

AV2 -0.02 7

AV1 -0.02 106 85 9

AV4 -0.05 14 AV1 +0.02 106 87 5

AV8 +0.40 5

AV7 -0.19 17 AV6 +0.07 8

AV5 -0.08 7

AV4 -0.09 16 AV2 -0.07 9

AV1 -0.05 106 89 12 AV7 -0.07 7

AV6 -0.05 8

AV5 +0.14 6

AV4 -0.21 7

AV3 -0.09 6

AV2 -0.21 106 91 9

AV7 -0.02 10 AV6 -0.02 12 AV4 -0.07 5

AV3 -0.23 106 93 9

AV6 -0.02 13 AV5 -0.03 14 AV4 -0.05 8

AV3 -0.07 13 AV2 -0.02 7

AV1 -0.02 106 95 9

AV7 -0.02 10 AV6 -0.07 15 AV5 -0.10 17 AV4 -0.02 11 AV3 +0.00 11 AV2 +0.00 106 97 5

AV7 -0.05 4

AV6 +0. 02 12 AV5 -0.03 17 AV4 +0.00 10 AV1 -0.05 106 99 8

AV4 -0.02 8

AV3 +0.00 7

AV2 -0.02 106 101 8 AV5 +0.07 106 103 7 AV4 +0.05 7

AV5 +0.05 6

AV6 +0.09 L-2019-064 Enclosure Page 78 of 89 Page 19 of 27 ROW COL %TW LOCATION 106 111 8 AV5 +0.05 106 119 6 AV4 +0.08 8

AV7 +0.05 106 129 6 AV3 +0.12 107 34 7

AV1 -0.07 7

AV2 +0.12 6

AV6 +0. 02 6

AV7 +0.05 11 AV8 +0. 07 107 46 8

AV3 +0.05 13 AV6 +0.07 107 50 8

AV7 +0.05 107 56 7

AV3 +0.10 7

AV4 +0.00 8

AV5 +0.09 107 60 7

AV2 +0.09 8

AV4 +0.03 7

AV5 +0. 05 107 62 6

AV3 +0.12 107 64 6

AV2 +0.09 7

AV5 +0.23 6

AV6+0.09 107 66 7

AV5 +0.05 107 68 8

AV2 +0.14 11 AV3 +0.14 9

AV4 +0.11 107 70 6

AV4 +0.03 8

AV5 +0.05 10 AV6 +0.05 6

AV8 +0.07 107 72 6

AV2 +0.05 7

AV7 +0. 07 107 74 11 AV3 +0.05 107 76 6

AV5 +0.12 16 AV4 -0.02 14 AV3 -0.05 7

AV2 -0.05 107 78 17 AV7 -0.07 12 AV5 -0.05 7

AV4 -0. 05 10 AV3 -0.05 7

AV1 +0.00 107 80 12 AV7 -0.05 8

AV6 -0.02 7

AV4 -0.05 107 82 7

AV7 -0.02 8

AV6 -0.02 18 AV5 -0.08 18 AV4 -0.07 14 AV3 -0.07 6

AV2 -0.20 107 84 18 AV7 -0.05 16 AV3 -0.05 7

AV2 -0.02 107 88 8

AV7 -0.05 8

AV6 -0.02 16 AV5 -0.05 15 AV4 -0.02 11 AV3 -0.02 7

AV2 -0.02 6

AV1 +0.00 107 90 8

AV7 +0.10 9

AV6 -0.02 10 AV5 -0.03 10 AV4 +0.00 9

AV3 +0.05 10 AV2 +0.02 107 92 14 AV7 +0.00 6

AV6 -0.02 19 AV2 +0.00 7

AV1 -0.07 107 94 17 AV6 -0.05

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 11 AV4 +0.00 6

AV3 -0.02 14 AV2 -0.02 5

AV1 -0.02 107 96 17 AV4 +0.03 107 98 4

AV7 +0.05 7

AV6 -0.02 10 AV4 -0.05 7

9 6

AV3 -0.05 AV2 -0.02 AV1 +0.14 107 100 13 AV4 +0.13 9

AV5 +0. 02 5

AV6 +0.02 11 AV7 +0.07 7

AV2 +0.09 107 104 6 AV4 +0.10 107 108 5 AV5 +0.02 107 112 8 AV5 +0.07 107 128 6 AV4 +0.18 7

AV5 +0.05 108 35 6

AV2 +0.21 108 45 5

AV3 +0.14 108 49 7

AV4 +0.18 10 AV5 +0.07 18 AV6 +0.07 108 61 5

AV3 +0.05 6

AV5 +0. 02 108 65 7

AV3 +0.07 8

AV4 +0.08 6

9 108 67 8

AV5 +0.05 AV6 +0.05 AV3 +0. 05 9

AV6 +0.07 6

AV7 +0. 05 108 71 7

AV4 +0.05 11 AV5 +0.07 11 AV6 +0. 05 108 73 6

AV2 +0.07 9

AV5 +0. 02 8

AV6 +0.05 108 75 5

AV4 -0.05 9

AV3 -0.23 108 77 6

AV6 +0.14 9

AV5 -0.03 8

AV3 -0.05 9

AV2 -0.02 108 79 6

AV6 -0.02 4

AV5 +0.28 5

AV4 -0.22 108 81 6

AV7 -0.02 8

AV2 -0.02 108 83 14 AV8 -0.05 19 AV7 -0.07 14 AV2 +0.02 10 AV1 -0.05 108 87 15 AV6 +0.12 18 AV5 -0.03 11 AV4 -0.05 6

AV7 -0.02 108 89 9

AV7 -0.02 14 AV6 -0.05 15 AV5 -0.05 8

AV4 -0.05 9

AV3 +0.02 8

AV2 -0.07 108 91 6

AV7 +0.30 17 AV3 -0.02 16 AV2 -0.02 108 93 8

AV7 +0.00 15 AV4 +0.03 16 AV3 +0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 17 AV2 +0.02 9

AVl +0.02 108 95 13 AV5 +0.00 18 AV4 -0.05 19 AV2 +0.00 5

AVl +0.13 108 97 7

AV8 -0.05 11 AV7 -0.02 12 AV6 -0.07 12 AV5 -0.08 13 AV4 -0.02 108 99 10 AV8 +0.00 12 AV7 -0.02 17 AV3 +0.00 108 101 10 AV3 +0.12 15 AV5 +0.00 9

AV6 +0.05 108 105 11 AV5 +0.10 108 107 7 AV5 +0.07 108 115 5 AV3 +0.05 6

AV4 +0.03 108 117 8 AV4 +0.05 7

AV5 +0.14 108 123 6 AV8 +0.07 108 125 7 AV3 +0.16 11 AV4 +0.21 10 AV5 +0.07 108 137 7 AV5 +0.05 109 48 7

AV5 +0.02 6

AV6 +0.05 109 54 8

109 62 7

8 109 64 7

8 AV5 +0. 05 AV4 +0. 03 AV5 +0. 02 AV5 +0.07 AV6 +0.05 7

AV7 +0.09 109 66 13 AV2 +0.10 7

AV3 +0.07 13 AV4 +0.11 10 AV5 +0.12 12 AV6 +0.09 109 68 7

AV2 +0.07 12 AV4 +0.05 7

AV5 +0.07 17 AV6 +0.07 10 AV7 +0.05 109 70 8

AV3 +0.02 7

AV4 +0.03 7

AV7 +0.09 109 72 6

AV3 +0.12 13 AV4 +0.03 109 74 8

AV3 +0.05 7

AV7 +0.07 109 76 6

AV7 -0.05 7

AV6 -0.02 11 AV4 -0.07 109 78 8

AV5 +0.17 109 80 9

AV3 -0.05 5

AV2 -0.14 109 82 8

AV7 -0.05 18 AV5 -0.08 13 AV4 +0.03 9

AV3 +0. 00 109 84 9

AV8 +0.05 13 AV6 -0.02 17 AV3 -0.05 11 AV2 -0.07 13 AVl +0.00 109 86 10 AV8 -0.05 13 AV3 -0.05 12 AV2 -0.05 109 88 5

AV6 -0.05 L-2019-064 Enclosure Page 79 of 89 Page 20 of 27 ROW COL %TW LOCATION 9

AV4 -0.09 8

AV3 -0.05 7

5 109 90 5

9 6

5 AV2 -0.07 AV1 +0.32 AV8 -0.35 AV6 -0.05 AV5 +0.14 AV4 -0.24 10 AV3 -0.14 109 92 8

AV7 -0.21 5

AV6 -0.14 6

AV5 +0.14 14 AV4 -0.05 9

AV3 +0.00 6

AV2 +0.28 109 94 9

AV6 -0.05 17 AV5 -0.05 12 AV4 +0. 00 10 AV3 -0.02 12 AV2 +0. 02 6

AV1 -0.05 109 96 12 AV4 -0.07 5

AV3 -0.05 109 98 9

AV6 +0.05 9

AV5 -0.03 8

AV1 +0.09 109 100 4 AV1 +0.14 14 AV2 +0.14 17 AV3 +0.16 13 AV4 +0.21 11 AV5 +0.10 8

AV7 +0.05 109 102 6 AV2 +0.07 6

AV3 +0.02 6

AV4 -0.05 109 104 6 AV5 +0.02 109 106 6 AV2 +0.05 6

AV5 +0.07 109 112 7 AV2 +0.05 109 114 10 AV3 +0.12 6

AV5 +0.14 7

AV6 +0.12 7

AV7 +0.11 109 130 8 AV6 +0.05 109 136 6 AV7 +0.05 110 51 11 AV5 +0.14 110 53 7

AV3 +0.00 8

AV4 +0.13 11 AV5 +0.07 110 59 6

AV3 +0.05 6

AV4 +0.13 7

AV5 +0.07 110 67 6

AV3 +0.09 110 69 8

AV4 +0.11 9

AV5 +0. 05 110 71 7

AV3 +0.12 9

AV4 +0.08 8

AV6 +0.09 110 73 6

AV3 +0.02 7

AV4 -0.12 110 75 8

AV5 -0.03 110 77 6

AV7 -0.02 6

AV6 -0.02 11 AV5 -0.05 11 AV4 -0.05 12 AV3 -0.05 7

AV2 -0.18 110 79 7

AV4 -0.02 7

AV3 -0.05 7

AV2 -0.05 110 81 6

AV4 -0.05 110 83 16 AV6 -0.07

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVE Wear 1-19%

ROW COL %TW LOCATION 8

AV3 +0.02 110 85 15 AV6 -0.07 16 AV2 +0.02 110 87 11 AV8 -0.05 17 AV7 -0.02 7

AV5 -0.05 14 AV4 -0.07 19 AV3 -0.02 5

AV2 -0.25 110 89 11 AV7 -0.07 17 AV5 +0.00 6

AV4 -0.21 4

AV2 -0.05 110 91 6

AV8 -0.05 13 AV7 -0.07 9

AV6 +0.00 15 AV5 -0.08 5

AV4 -0.14 6

AV3 -0.21 110 93 9

AV7 +0.00 5

AV5 +0.33 12 AV4 -0.05 8

AV2 -0.07 110 95 6

AV6 -0.07 10 AV5 -0.08 13 AV3 +0.00 11 AV2 +0.00 110 97 5

AV4 -0.23 16 AV3 -0.02 5

AV7 +0.25 6

AV5 -0.05 110 99 14 AV5 -0.03 10 AV4 -0.02 7

AV3 -0.07 5

AV2 +0.14 110 101 8 AV1 +0.14 12 AV2 +0.14 15 AV3 +0.14 12 AV4 +0.18 18 AV6 +0.02 12 AV7 +0.05 110 103 7 AV2 +0.17 12 AV3 +0.17 10 AV4 +0.18 9

AV6 +0.12 110 107 7 AV4 +0.15 110 127 8 AV4 +0.13 7

AV7 +0.05 110 129 9 AV5 +0.05 111 50 9

AV6 +0.30 111 72 6

AV4 +0.00 7

AV6 +0.07 111 74 10 AV3 +0.05 7

AV6 +0.05 111 76 8

AV4 -0.02 6

AV3 -0.21 9

AV2 -0.05 111 78 6

AV5 +0.14 14 AV4 -0.02 7

AV3 -0.05 111 80 4

111 82 7

AV7 +0.19 AV5 -0.03 5

AV3 +0.10 111 84 18 AV7 -0.05 17 AV6 -0.07 7

AV2 +0.00 111 86 17 AV8 +0.00 7

AV5 -0.03 10 AV3 -0.05 10 AV2 -0.05 111 88 11 AV6 -0.02 11 AV5 -0.08 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 15 AV4 -0.05 12 AV3 -0.02 7

AV2 +0.00 111 90 10 AV6 -0.05 15 AV5 -0.08 10 AV3 +0.00 111 92 5

AV7 +0.17 4

AV6 +0.16 6

AV5 +0.16 4

AV4 -0.24 8

AV3 -0.02 11 AV2 +0.00 6

AV1 -0.02 111 94 6

AV6 -0.05 8

AV4 -0.07 11 AV3 -0.05 7

AV2 -0.02 111 96 7

AV7 +0.00 19 AV4 +0.03 13 AV3 +0.02 12 AV2 +0.05 11 AV1 +0.00 111 98 16 AV7 -0.02 12 AV6 -0.05 12 AV5 -0.05 18 AV4 +0.03 13 AV3 +0.00 12 AV2 +0.05 7

AV1 +0.02 14 AVB +0.00 111 100 8 AV2 +0.14 7

AV3 +0.14 111 102 17 AV2 +0.02 18 AV4 +0.00 14 AV8 +0.05 111 128 8 AV4 +0.10 6

AV5 +0.02 112 63 9

AV5 +0.05 10 AV6 +0.02 14 AV7 +0.09 9

AV8 +0.07 112 69 14 AV1 +0.07 15 AV2 +0.05 13 AV3 +0.02 11 AV4 -0.02 112 71 7

AV2 +0.12 9

AV3 +0.12 8

AV4 +0.11 8

AV6 +0. 02 112 73 15 AV1 +0.05 10 AV2 +0.05 17 AV3 +0.05 13 AV4 +0.05 12 AV6 +0.02 15 AV7 +0.07 9

AV8 +0. 05 112 81 6

AV4 -0.02 112 87 9

AV7 +0.00 9

AV6 +0.09 16 AV5 -0.05 11 AV3 +0.02 112 89 11 AV2 -0.02 10 AV7 -0.02 12 AV6 -0.02 9

AV5 -0.08 8

AV4 -0.07 8

AV3 +0.00 112 91 10 AV7 -0.02 11 AV5 -0.10 18 AV4 -0.05 14 AV3 +0.05 9

AV2 +0. 02 L-2019-064 Enclosure Page 80 of89 Page 21 of 27 ROW COL %TW LOCATION 8

AV1 +0.07 112 93 8

AV5 -0.08 7

AV4 +0.05 12 AV2 +0.00 7

AV1 +0.02 112 95 5

AV7 +0.12 5

AV6 +0.44 5

AV5 -0.05 5

AV4 +0.08 16 AV3 -0.02 7

AV2 -0.23 112 97 7

AV6 -0.05 11 AV5 -0.05 12 AV4 -0.05 9

AV3 -0.02 5

AV2 +0.30 112 99 8

AV6 -0.05 10 AV5 -0.08 14 AV4 +0.00 18 AV3 +0.00 9

AV2 +0.00 112 101 8 AV2 +0.07 15 AV3 +0.07 16 AV4 +0.10 8

AV7 +0. 07 112 103 6 AV3 +0.09 7

AV5 +0.07 11 AV6 +0.05 16 AV7 +0. 02 112 105 7 AV4 +0.11 112 119 7 AV4 +0.00 7

AV6 +0.05 112 121 6 AV4 +0.10 113 42 8

AV3 +0.07 6

AV4 +0.19 6

AV6 +0.02 113 48 8

9 8

113 56 9

113 66 9

AV4 +0.03 AV5 +0.00 AV6 +0. 00 AV5 +0. 05 AV4 +0. 08 9

AV5 +0.12 6

AV6 +0.07 113 68 15 AV2 +0.12 11 AV6 +0.12 113 72 6

AV5 +0.21 113 74 9

AV6 +0.07 113 80 6

AV6 +0.00 7

AV3 -0.02 113 82 7

AV3 -0.02 113 88 13 AV6 +0.00 14 AV4 -0.07 7

AV3 -0.09 7

AV2 -0.18 113 90 5

AV8 -0.02 15 AV7 -0.02 14 AV6 -0.02 13 AV5 -0.03 5

AV4 -0.02 7

AV3 -0.21 113 92 4

5 AV6 +0.14 AV5 +0. 42 5

AV4 +0.08 6

AV3 -0.21 4

AV2 +0.14 5

AV7 -0.14 113 94 6

AV7 -0.05 6

AV6 +0.07 14 AV5 -0.05 14 AV4 +0.00 14 AV3 +0.00 7

AV2 +0. 02

Frarnatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 113 96 7

AV7 +0.00 10 AV6 -0.02 9

AV5 -0.08 14 AV4 +0.00 15 AV3 +0.00 12 AV2 +0.05 113 98 5

AV5 -0.08 10 AV3 +0.00 7

AV2 -0.02 4

AV4 -0.05 113 100 8 AV2 +0.07 8

AV6 +0.02 113 102 6 AV4 +0.16 113 118 10 AV2 +0.09 114 41 10 AV3 +0.07 6

AV4 +0.00 10 AV6 +0.05 114 43 8

AV2 +0.09 7

AV5 +0.12 7

AV6 +0.07 6

AV7 +0.21 114 57 6

AV4 +0.22 9

AV5 +0.09 114 65 9

AV5 +0.02 114 73 7

AV2 +0.09 7

114 7 5 6

9 AV4 +0.08 AV4 -0.05 AV3 -0.07 10 AV2 -0.05 9

AV1 -0.05 114 77 7

AV6 -0.05 7

AV4 -0.02 7

AV3 -0.05 114 79 7

AV6 +0.05 114 81 6

AV7 -0.07 6

AV6 -0.02 7

AV4 -0.02 114 83 12 AV7 -0.07 16 AV4 -0.07 8

5 AV3 -0.07 AV2 -0.07 114 87 15 AV7 -0.05 19 AV6 -0.02 16 AV2 -0.02 10 AV1 -0.02 114 89 5

AV8 +0.12 19 AV5 -0.05 8

AV4 -0.26 14 AV3 -0.07 13 AV2 -0.05 8

AV1 -0.05 114 91 8

AV7 +0.10 11 AV6 -0.05 6

AV5 -0.05 16 AV4 -0.07 13 AV3 -0.02 5

AV2 +0.00 114 93 5

AV4 +0.31 6

AV3 -0.09 5

AV2 -0.18 114 95 13 AV5 -0.05 10 AV4 -0.09 11 AV3 -0.05 6

AV2 -0.23 114 97 5

AV5 +0.26 7

AV3 -0.07 114 99 7

AV7 -0.02 12 AV6 -0.07 18 AV4 +0.03 13 AV2 +0.02 114 101 7 AV1 +0.14 16 AV2 +0.14 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 15 AV3 +0.14 15 AV4 +0.16 7

AV5 +0.05 114 103 6 AV2 +0.23 8

AV5 +0. 00 114 123 6 AV5 +0.05 115 40 6

AV3 +0.09 6

AV4 +0.11 11 AVS +0.11 115 56 9

AV4 +0.05 6

AV5 +0.09 7

AV6 +0.09 7

AV7 +0.07 115 58 7

AV2 +0.05 5

AV3 +0.00 6

AV4 +0.19 7

AV5 +0.09 115 60 13 AV3 +0.07 9

AV4 +0.11 8

AV5 +0.07 115 66 10 AV4 +0.22 8

AV5 +0.09 12 AV6 +0.09 16 AV7 +0.12 13 AVS +0.11 115 70 8

AV4 +0.08 7

AV5 +0.12 18 AV6 +0.09 8

115 72 7

8 115 74 7

AV7 +0.09 AV1 +0.00 AV2 +0. 05 AV1 +0.05 10 AV2 +0.07 9

AV3 +0.02 9

AV4 +0.03 115 82 19 AV5 +0.00 7

AV3 -0.05 115 84 9

AVS +0.02 17 AV6 -0.02 18 AV5 -0.05 17 AV3 -0.02 14 AV2 +0.00 19 AV1 -0.02 115 88 10 AVS -0.02 16 AV7 -0.05 14 AV6 -0.02 10 AV3 -0.05 8

AV2 -0.02 115 90 10 AV7 -0.02 17 AV6 -0.07 18 AV5 -0.13 10 AV3 -0.05 7

AV2 -0.02 115 92 8

AV7 +0.02 8

AV6 +0.00 11 AV5 -0.03 10 AV2 +0.00 115 94 8

AV7 +0.00 11 AV6 -0.02 9

AV3 -0.07 115 96 15 AV7 +0.00 16 AV2 +0.02 115 100 7 AV2 +0.11 8

AV5 +0.21 115 102 11 AV2 +0.07 11 AV3 +0.09 15 AV4 +0.08 12 AV5 +0.02 115 104 7 AV5 +0.02 115 112 6 AV3 +0.21 115 116 8 AV3 -0.02 115 122 6 AV3 +0.19 L-2019-064 Enclosure Page 81 of 89 Page 22 of 27 ROW COL %TW LOCATION 115 130 6 AV5 +0.19 12 AV6 +0.05 116 55 12 AV4 +0.13 10 AV5 +0.07 8

AV6 +0.09 116 57 7

AV3 +0.05 12 AV5 +0.07 116 59 7

AV3 +0.05 8

AV5 +0.07 116 61 8

AV5 +0.02 116 63 8

AV3 +0.09 AV5 +0. 02 116 69 9

AV2 +0.09 9

AV3 +0.09 11 AV4 +0.11 12 AV5 +0.02 116 71 10 AV4 +0.05 116 73 6

AV4 +0.00 116 77 7

AV6 +0.12 116 79 6

AV4 -0.21 6

AV3 -0.18 6

AV2 -0.02 116 81 5

AV6 -0.07 6

AV4 -0.07 116 83 11 AV6 -0.07 12 AV5 -0.10 16 AV3 +0.00 14 AV2 +0.00 116 87 16 AVS +0.00 18 AV5 -0.10 17 AV4 -0.05 13 AV3 +0.00 12 AV2 +0.02 8

AV1 +0.02 116 89 9

AV6 -0.09 12 AV4 -0.07 7

AV2 +0.02 116 91 7

AV7 +0.14 8

AV6 -0.02 10 AV5 -0.05 5

AV4 -0.19 7

AV3 -0.05 116 93 9

AV5 -0.03 11 AV4 -0.02 5

AV3 +0.05 116 95 14 AV5 -0.05 10 AV4 -0.05 4

AV3 +0.14 5

AV2 -0.18 116 97 7

AV5 -0.10 10 AV2 +0.05 5

AV1 +0.02 116 99 7

AV3 +0.02 117 78 6

AV3 -0.09 7

AV2 -0.02 117 82 7

AV5 -0.03 117 84 18 AV7 -0.05 9

AV4 -0.02 8

AV3 +0.02 17 AV2 +0.05 117 86 12 AVS -0.05 19 AV7 -0.05 17 AV6 -0.07 15 AV4 -0.07 5

AV3 +0.23 5

AV2 -0.18 117 88 7

AV6 -0.02 7

AV5 -0.03 5

AV4 -0.21 7

AV3 -0.09 8

AV2 -0.05 117 90 6

AV8 +0.00

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 9

AV7 -0.07 12 AV6 -0.05 19 AV5 -0.03 7

AV4 -0.02 117 92 5

AV7 +0.17 5

AV6 +0.19 7

AV5 +0. 00 8

AV3 -0.12 9

AV2 -0.05 117 94 8

AV2 +0.02 117 98 5

AV7 -0.05 4

AV6 +0.42 6

AV5 -0.03 7

AV3 -0.25 6

AV2 -0.20 117 100 11 AV2 +0.11 9

AV3 +0.09 8

AV5 +0.02 118 79 6

AV2 -0.21 118 83 13 AV7 -0.05 19 AV6 -0. 05 14 AV4 -0.05 8

AV3 -0.02 7

AV2 -0.05 118 87 5

AV8 -0.02 5

AV7 -0.05 13 AV6 -0.02 15 AV3 -0.05 14 AV2 -0.07 118 89 6

AV6 +0.42 14 AV5 +0.00 15 AV4 -0.05 6

AV3 -0.21 5

AV2 +0.18 118 91 14 AV7 -0.05 14 AV6 -0.05 11 AVS -0.03 5

AV4 -0.07 5

AV3 -0.18 6

AV2 -0.05 118 93 13 AV7 -0.05 14 AV6 -0.05 9

AV4 -0.02 7

AV3 -0.02 13 AV2 -0.02 9

AV1 +0.05 118 95 5

AVS +0.09 12 AV4 -0.05 5

AV3 -0.05 9

AV2 -0.02 4

AV1 +0.29 118 97 16 AVS -0.03 5

AV2 +0.14 118 99 11 AV8 +0.02 19 AV7 -0.02 13 AV6 -0.02 10 AVS +0.00 11 AV4 +0. 03 8

AV3 +0.00 6

AV2 +0.00 118 101 6 AV7 -0.02 118 103 7 AVS +0.05 8

AV7 +0.02 118 127 10 AV7 +0.07 119 78 7

AV7 -0.07 7

AV6 -0.02 5

AV4 -0.02 119 82 8

AV8 -0.02 13 AV7 -0.02 17 AV4 -0.07 9

AV3 -0.07 119 84 8

AV6 +0.07 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 13 AV4 -0.05 13 AV3 -0.05 10 AV1 -0.07 119 88 10 AV7 -0.07 15 AV6 -0.02 8

AV4 -0.02 10 AV3 +0. 00 13 AV2 +0.00 119 90 14 AV7 -0.07 15 AV6 -0.05 13 AV5 -0.05 8

AV3 +0. 02 7

AV1 +0.02 119 92 8

AV7 -0.23 4

AV6 +0.44 8

AVS -0.05 5

AV3 +0.12 119 94 6

AV2 -0.20 5

AV1 +0.43 119 96 8

AV1 +0.00 119 124 5 AVS +0.23 120 61 8

AV7 +0.09 120 81 5

AV4 +0.08 120 83 4

AV6 -0.36 13 AVS -0.05 12 AV4 -0.19 9

AV3 -0.05 120 85 14 AV8 -0.02 6

AV6 -0.02 7

AV2 -0.09 120 87 15 AV4 -0.02 13 AV7 -0.05 17 AV6 -0.02 16 AVS -0.08 120 89 8

AVB -0.10 7

AV7 -0.05 8

AV6 -0.05 8

AV5 -0.10 9

AV4 -0.02 6

AV3 +0.00 8

AV2 +0.00 120 91 10 AVB -0.05 15 18 14 120 93 7

9 120 97 6

4 120 105 7 120 117 6 120 119 8 120 123 6 5

121 58 7

8 8

121 62 9

121 68 10 121 74 6

7 8

121 82 8

AV7 +0.00 AVS -0.10 AV2 +0.00 AV3 +0.05 AV2 +0.00 AV3 -0.07 AV2 +0.16 AVS' +0. 05 AV4 +0.10 AV7 +0.09 AV2 +0.14 AV4 -0.16 AV4 +0. 05 AV5 +0. 07 AV6 +0.07 AV6 +0. 05 AV4 +0. 05 AV2 +0.07 AV3 +0.17 AV4 +0.00 AV6 -0.02 10 AVS -0.05 121 84 14 AVS -0.08 19 AV4 +0.00 9

AV3 -0.02 13 AV7 -0.07 121 88 7

AV2 +0.00 18 AV7 -0.05 15 AVS -0.05 8

AV4 -0.07 L-2019-064 Enclosure Page 82 of 89 Page 23 of 27 ROW COL %TW LOCATION 8

AV3 -0.05 121 90 AVB +0.00 13 AV7 -0.05 12 AV6 -0.07 15 AV5 -0.03 12 AV3 -0.05 5

AV2 -0.20 121 92 10 AV7 +0.17 4

AV6 +0.44 7

AV3 -0.18 6

AV2 -0.05 5

AV1 +0.45 121 94 6

AV4 -0.05 8

AV3 -0.07 5

AV2 -0.16 121 98 5

AV7 -0.05 121 100 5 AV2 -0.37 9

AV4 +0.05 121 102 6 AV1 +0.07 7

AV3 +0.07 7

AV4 +0.00 9

AV5 +0.00 11 AV7 +0. 02 122 73 8

AV4 +0.08 122 79 7

AV7 -0.09 14 AV6 -0.05 122 83 13 AV5 -0.03 16 AV3 +0.00 10 AV2 -0.02 7

AV1 -0.02 122 87 10 AVB +0.00 8

AV7 -0.02 13 AV2 -0.02 122 89 8

AV6 +0.00 13 AV5 -0.03 18 AV4 +0.00 10 AV3 +0.05 8

AV2 -0.02 122 91 7

AVB -0.05 8

AV7 -0.07 8

AV6 -0.05 17 AV5 -0.10 8

10 8

122 93 8

10 10 122 95 8

7 12 11 122 97 5

7 6

122 99 10 5

7 6

122 101 6 8

7 122 103 14 AV3 -0.02 AV2 -0.02 AV1 +0.05 AV7 +0.14 AVS -0.10 AV2 +0.00 AV5 -0.16 AV4 -0.09 AV3 -0.05 AV2 +0.00 AV6 +0.07 AVS -0.03 AV2 -0.05 AV7 +0.17 AVS +0.19 AV4 -0.05 AV2 -0.18 AV3 -0.07 AV4 +0.19 AVS +0.07 AV2 +0.12 13 AV4 +0.18 9

AV6 +0.12 122 109 7 AV4 +0.25 9

AV6 +0.12 7

AV7 +0.02 7

AVB +0.07 123 70 11 AV4 +0.05 10 AV5 +0.00 8

AV7 +0.07

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 123 72 5

AV2 -0.05 7

AV5 +0.21 5

AV3 +0.38 123 74 7

AV3 +0.09 11 AV6 +0.05 8

AV7 +0.07 123 78 6

AV3 -0.05 123 82 8

AV6 -0.02 5

AV4 +0.11 5

AV2 -0.05 123 84 8

AV8 +0.02 7

AV5 -0.10 7

AV3 -0.02 123 86 10 AV6 -0.07 11 AV4 -0.07 15 AV3 +0.00 6

AV2 -0.21 123 88 11 AV8 +0.02 14 AV7 -0.05 9

AV6 -0.05 9

AV5 -0.08 8

AV3 +0.00 9

AV2 +0.00 123 90 9

AV7 -0.02 6

AV6 +0.14 9

AV3 -0.09 5

AV2 +0.14 123 92 7

AV7 +0.19 6

AV2 -0.07 123 94 8

AV5 +0.02 16 AV4 -0.05 8

AV3 -0.02 8

AV2 -0.07 123 98 8

AV7 +0.02 12 AV6 +0.02 16 AV4 +0.03 10 AV2 +0. 02 124 55 7

AV3 +0.10 7

AV4 +0.11 6

AV5 +0.00 6

AV6 +0. 05 6

AV7 +0.05 124 69 7

AV5 +0.05 124 71 10 AV4 +0.08 124 83 13 AV6 -0.05 16 AV5 -0.05 14 AV4 -0.05 8

AV3 -0.07 124 87 11 AV3 -0.05 15 AV2 +0.02 12 AV1 +0. 02 9

AV7 -0.02 9

AV6 -0.02 124 89 13 AV6 -0.09 10 AV5 -0.08 8

AV3 -0.05 124 91 15 AV6 -0.02 14 AV5 -0.10 7

AV2 +0. 02 124 93 7

AV3 +0.00 9

AV4 +0.00 8

AV2 +0.00 7

AV1 +0.00 124 95 6

AV3 +0.00 8

AV2 -0.02 124 97 4

AV5 +0.12 124 99 8

AV7 +0.02 6

AV2 +0.00 125 54 9

AV3 +0.12 8

AV4 +0.13 8

8 AV5 +0.07 AV6 +0. 05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 125 56 8

AV2 +0.09 6

AV3 +0.10 125 62 8

AV2 +0.14 11 AV4 +0.11 12 AV5 +0.00 125 68 8

AV2 +0.14 9

AV3 +0.12 10 AV4 +0.03 9

125 72 6

AV5 +0.00 AV1 +0.11 9

AV2 +0.12 11 AV3 +0.14 14 AV4 +0.13 125 82 10 AV7 +0.00 5

AV6 +0.00 8

AV4 +0.16 125 84 6

AV6 +0.38 17 AV5-0.11 19 AV4 -0.07 11 AV3 -0.18 125 88 4

AV8 +0.14 13 AV6 -0.07 5

AV2 +0.39 125 90 6

AV8 -0.02 15 AV7 -0.07 14 AV6 -0.09 10 AV5 -0.05 16 AV4 -0.07 6

AV2 -0.25 4

AVl +0.29 125 92 6

AV7 -0.02 5

AV3 -0.18 125 94 8

AV5 -0.05 5

AV4 +0.42 5

AV3 -0.16 6

AV2 -0.20 125 96 17 AV4 +0.00 12 AV1 +0.05 125 98 17 AV4 -0.05 5

AV3 -0.07 125 100 7 AV4 +0.03 8

AV5 +0.05 9

AV7 +0.11 9

AV8 +0.09 125 102 7 AV1 +0.07 9

AV2 +0.09 13 AV3 +0.09 14 AV5 +0.09 126 55 7

AV3 +0.14 6

AV4 +0. 00 11 AV5 +0.00 15 AV6 -0.02 7

AV7 +0.02 126 69 9

AV4 +0.16 126 75 6

AV3 -0.23 126 77 8

AV3 -0.02 126 83 7

AV8 +0.05 6

AV7 -0.02 7

AV6 -0.07 16 AV5 -0.08 13 AV4 -0.05 8

AV3 -0.02 126 87 14 AV7 -0.05 8

AV6 +0.12 8

AV5 -0.08 14 AV4 -0.09 7

AV3 -0.05 8

AV2 -0.05 126 89 13 AV6 -0.07 10 AV5 -0.05 126 91 10 AV7 -0.19 10 AV5 -0.05 L-2019-064 Enclosure Page 83 of 89 Page 24 of 27 ROW COL %TW LOCATION 6

AV3 -0.23 126 93 6

AV6 +0.14 6

AV3 -0.02 10 AV2 +0.02 126 97 5

AV7 +0.10 12 6 99 6

126 101 9 8

126 103 6 8

AV4 +0. 00 AV3 +0. 05 AV4 +0.16 AV1 +0.05 AV4 +0.10 126 105 10 AV4 +0.08 126 119 9 AV4 +0.10 127 66 10 AV6 +0.05 127 68 7

AV2 +0.12 9

AV3 +0.07 12 AV4 +0.05 8

AV5 +0.05 18 AV6 +0.05 12 AV7 +0. 07 127 74 10 AV3 +0.02 8

AV4 +0.05 6

AV6 -0.14 127 82 4

AV6 -0.30 6

AV4 +0.21 5

AV3 +0.14 127 84 8

AV7 +0.02 16 AV6 -0.05 14 AV5 -0.05 17 AV4 -0.02 12 AV3 -0.09 12 AV2 -0.02 127 86 13 AV6 -0.05 14 AV4 -0.07 16 AV3 +0.00 8

AV2 +0. 00 127 88 5

AV7 -0.05 10 8

127 90 7

10 9

13 7

9 127 92 8

7 127 94 6

127 96 5

127 98 8

AV6 -0.05 AV2 -0.18 AV8 +0.00 AV7 -0.05 AV5 -0.05 AV4 -0.07 AV3 -0.27 AV1 +0.00 AV7 +0.05 AV3 -0.05 AV2 -0.20 AV5 +0.12 AV5 +0.19 5

AV4 +0.32 8

AV3 +0.00 127 100 6 AV4 +0.11 6

AV5 +0.09 127 102 7 AV1 +0.07 10 AV2 +0.11 7

AV3 +0.12 14 AV4 +0.03 8

AV5 +0.07 9

AV7 +0.07 127 104 6 AV3 +0.05 7

AV7 +0.05 127 106 12 AV4 +0.16 127 108 7 AV4 +0.13 8

AV5 +0. 05 127 118 6 AV6 +0.07 128 53 17 AV4 -0.02 10 AV6 +0.00 7

AV7 +0.23 128 67 7

AV3 +0.07 8

AV5 +0.00 7

128 71 6

AV6 -0.12 AV2 +0.09

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 15 AV4 +0.11 10 AV8 +0.07 128 73 5

AV4 +0.08 5

AV8 +0.23 5

AV6 +0.00 128 75 7

AV5 -0.03 8

AV4 -0.07 128 77 7

AV4 -0.05 7

AV3 -0.02 128 79 7

AV2 +0.00 128 81 7

AV6 -0.09 9

AV4 +0.00 128 83 7

AV7 -0.05 7

AV6 -0.05 6

AV4 -0.24 8

128 85 7

AV3 +0.00 AV6 -0.07 10 AV2 -0.02 128 87 10 AV6 +0.00 10 AV5 -0.08 128 89 6

AV7 -0.02 5

AV6 -0.02 128 91 6

AV8 -0.02 13 AV7 -0.02 13 AV6 -0.02 9

AV5 -0.05 11 AV4 -0.09 9

AV3 -0.07 7

AV2 -0.07 128 95 8

AV3 -0.02 128 97 5

AV5 +0.16 5

AV4 +0.00 5

AV3 +0.35 7

AV2 -0.02 4

AVl +0.22 128 99 8

AV7 -0.02 128 101 9 AV8 +0.07 9

AV4 +0.13 10 AV6 +0. 05 15 AV7 +0.05 128 103 13 AV2 +0.09 19 AV3 +0.09 18 AV4 +0.11 12 AV7 +0.02 128 105 10 AV3 +0.07 8

AV4 +0.05 128 107 9 AV7 +0.07 128 109 6 AV3 +0.12 5

AV4 +0.18 9

AV5 +0.12 128 111 9 AV3 +0.02 9

AV4 +0.08 15 AV5 +0. 02 12 AV6 +0.07 128 117 14 AV4 +0.00 6

AV5 +0.05 10 AV6 +0.05 14 AV7 +0.05 10 AV8 +0.07 129 66 9

AV5 +0.05 10 AV6 +0.05 129 68 11 AV2 +0.14 18 AV3 +0.09 7

AV5 +0.02 129 72 5

AV2 +0.00 129 74 8

AV6 -0.12 129 76 10 AV4 -0.05 7

AV3 -0.09 129 78 13 AV6 -0.19 129 80 6

AV4 -0.30 129 82 6

AV4 +0.19 129 84 10 AV7 -0.02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 5

AV6 +0.28 18 AV5 -0.08 14 AV4 -0.07 16 AV3 -0.07 129 86 18 AV7 -0.02 13 AV5 +0.00 129 88 8

9 AV7 -0.02 AV5 -0.10 9

AV4 -0.07 8

AV2 +0.00 129 90 6

AV8 +0.02 13 AV7 -0.05 9

AV6 -0.05 12 AV5 -0.03 16 AV4 -0.07 11 AV3 -0.07 129 92 11 AV7 +0.00 7

AV6 +0.07 8

AV5 -0.08 7

AV3 +0.00 9

AV2 +0.02 129 94 10 AV7 +0.02 9

AV4 +0.00 10 AV3 -0.05 AV2 +0.02 129 96 8

AV7 -0.07 10 AV6 +0. 00 9

AV5 -0.10 7

AV4 +0.00 129 98 7

AV6 -0.05 129 102 8 AV2 +0.07 12 AV3 +0.02 15 AV5 +0.05 129 112 6 AV4 +0.05 10 AV6 +0. 09 6

AV7 +0.28 130 67 7

AV2 +0.14 14 AV3 +0.07 8

AV7 +0.07 130 69 6

AV1 +0.09 13 AV2 +0.07 8

AV3 +0.02 14 AV4 +0.08 8

AV6 -0.02 130 73 8

AV3 +0.05 8

AV4 +0. 05 130 83 6

AV5 -0.03 6

AV3 -0.02 5

AV2 +0.48 130 87 8

AV7 +0.00 11 AV6 -0.07 15 AV5 -0.08 130 89 13 AV6 -0.09 16 AV5 -0.10 16 AV4 -0.07 13 AV2 +0.00 130 91 5

AV7 +0.16 9

AV6 +0.00 17 AV5 -0.03 5

AV4 -0.07 8

AV2 -0.07 130 93 6

AV7 +0.46 8

AV4 -0.05 13 AV2 -0.02 130 95 14 AV8 +0.02 13 AV7 -0.02 4

AV5 +0.19 8

AV4 -0.12 8

AV3 -0.07 130 97 13 AV5 +0.02 11 AV4 -0.05 7

AV3 -0.07 L-2019-064 Enclosure Page 84 of89 Page 25 of 27 ROW COL %TW LOCATION 130 99 11 AV4 +0.05 7

AV3 +0.00 7

AV2 +0.02 130 101 6 AV1 +0.12 10 AV4 +0.18 130 103 8 AV1 +0.09 14 AV2 +0.12 14 AV3 +0.07 14 AV4 +0.05 6

AV5 +0.00 14 AV7 +0.09 7

AV8 +0.00 130 113 7 AV4 +0.03 131 66 7

AV3 +0.09 131 68 14 AV4 +0.03 14 AV5 +0.05 8

AV6 +0.05 131 70 5

AV3 +0.10 15 AV6 +0.14 7

AV7 +0.14 11 AV8 +0.11 131 72 8

AV6 +0.23 7

AV8 +0.16 131 74 10 AV5 +0.00 9

AV4 +0.08 7

AV2 +0.09 131 78 6

AV6 -0.26 131 82 13 AV4 +0.29 8

AV3 -0.05 131 84 5

AV6 +0.44 131 86 12 AV8 +0.05 14 AV3 -0.02 8

AV2 -0.05 5

AV1 +0.30 131 88 5

AV7 -0.02 9

AV6 -0.02 5

AV5 +0.02 6

AV2 -0.23 131 90 9

AV7 +0.00 11 AV6 -0.02 9

AV3 +0.00 9

AV2 +0.05 16 AV1 +0.02 131 92 9

AV7 +0.19 9

AV6 +0.02 6

AV3 -0.23 131 94 8

AV5 +0.00 6

AV4 +0.00 11 AV3 +0.14 6

AV2 -0.07 6

AV1 -0.02 131 96 6

AV7 +0.00 7

AV5 +0.14 131 98 8

AV5 -0.03 7

AV4 -0.02 11 AV3 -0.05 131 100 5 AV2 +0.09 131 102 8 AV1 +0.02 11 AV2 +0. 05 18 AV7 +0.07 16 AV8 +0.12 131 104 9 AV3 +0.10 7

AV4 +0.16 11 AV5 +0. 07 16 AV6 +0.09 132 67 9

AV3 +0.00 11 AV5 +0.02 132 69 10 AV4 +0.05 11 AV5 +0.02 9

AV7 +0.07 132 71 10 AV4 +0.03 5

AV5 +0.30

Frarnatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 1-19%

ROW COL %TW LOCATION 16 AV7 +0. 05 6

AV8 -0.07 132 73 6

AV4 +0.13 8

AV7 +0.05 5

AV2 +0.30 132 75 7

AV8 -0.12 6

AV5 -0.24 6

AV2 +0.02 132 77 15 AV6 -0.02 6

AV4 -0.02 132 79 8

AV6 -0.02 7

AV4 +0.03 132 81 11 AV6 -0.12 8

AV5 -0.13 8

AV4 -0.33 132 85 6

AV5 +0.12 8

AV3 -0.05 132 89 6

AV7 -0.02 8

AV6 -0.05 8

AV5 -0.05 12 AV4 -0.09 7

AV3 -0.23 132 91 8

AV8 -0.05 10 AV7 +0.00 16 AV6 -0.05 7

7 AV4 -0.02 AV3 -0.09 6

AV2 -0.05 132 93 7

AV7 -0.05 6

AV6 +0.12 6

AV5 -0.08 6

AV4 -0.09 132 95 10 AV7 +0.00 7

AV6 -0.09 12 AV5 -0.08 9

AV4 -0.05 9

AV3 -0.07 132 97 4

AV7 +0.19 5

AV5 +0.07 132 99 8

AV6 -0.05 9

AV4 +0.03 12 AV3 +0.02 7

AV2 +0.00 132 101 11 AV4 +0.10 8

AV2 +0.07 10 AV3 +0.14 133 62 7

AV7 +0.05 6

AV6 +0.23 133 70 8

AV4 -0.12 12 AV5 +0.00 13 AV7 +0. 05 7

AV8 +0.25 133 72 17 AV5 -0.05 133 74 133 76 133 78 133 80 133 82 133 84 133 86 133 88 133 90 133 92 6

AV4 +0. 08 11 AV5 +0.00 6

AV2 -0.21 8

AV6 -0.19 9

AV4 -0.05 6

AV6 +0. 00 9

AV6 -0.05 4

AV6 +0.14 8

AV6 +0.02 9

AV5 -0.08 12 AV2 +0.05 13 AV7 +0.00 16 AV6 -0.05 18 AV5 -0.05 19 AV4 -0.05 11 AV3 -0.20 9

AV2 -0.02 10 AV4 -0.05 8

AV2 +0. 02 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 8

AV6 -0.07 16 AV5 -0.08 133 94 7

7 AV5 -0.18 AV3 -0.07 133 96 11 AV7 -0.02 12 AV6 -0.07 6

AV5 -0.08 7

9 8

AV4 +0. DO AV3 -0.02 AV2 +0.02 6

AV1 +0.05 133 102 8 AV1 +0.07 19 AV2 +0.07 8

AV3 +0.09 134 69 8

AV2 +0.09 7

AV4 +0.05 8

AV5 +0.00 8

AV7 +0.16 134 71 11 AV5 -0.13 9

AV3 +0.05 16 AV7 +0.07 7

AV8 -0.09 14 AV6 +0.09 134 73 9

AV5 -0.08 7

AV6 -0.21 7

5 AV7 -0.18 AV8 -0.07 134 75 8

AV8 -0.17 7

AV7 +0.00 7

AV4 -0.05 134 77 10 AV4 -0.07 134 79 8

AV6 -0.02 9

AV4 -0.07 134 81 9

AV7 +0.00 16 AV6 -0.09 11 AV5 -0.13 9

AV4 -0.19 134 83 5

AV8 +0.17 5

AV6 -0.02 10 AV4 -0.25 6

AV2 -0.05 134 87 5

AV5 +0.09 134 89 6

AV7 -0.07 10 AV6 -0.07 11 AV5 -0.13 12 AV4 -0.05 9

AV3 -0.07 8

AV2 +0. 05 134 91 14 AV7 -0.02 7

AV6 -0.02 7

AV3 -0.20 134 93 8

AV7 -0.02 9

AV4 -0.09 11 AV3 -0.05 134 95 134 97 135 70 135 72 135 76 135 78 135 80 135 82 9

AV5 -0.13 7

AV7 -0.02 8

AV8 +0.25 6

AV8 -0.14 8

AV7 +0.00 7

AV6 +0.19 8

AV5 -0.08 7

AV4 -0.07 6

AV3 +0.00 9

AV4 +0.00 8

AV2 -0.02 6

AV8 -0.17 7

AV7 +0.14 12 AV6 +0.00 15 AV5 +0.02 8

AV4 +0.00 6

AV2 -0.05 17 AV8 +0.05 L-2019-064 Enclosure Page 85 of 89 Page 26 of 27 ROW COL %TW LOCATION 14 AV2 +0.07 135 84 4

AV8 +0.10 5

AV7 +0.17 11 AV6 -0.02 10 AV5 -0.05 135 86 11 AV6 -0.09 8

AV5 -0.08 14 AV4 +0. 03 11 AV3 +0.00 7

AV2 +0. 00 135 90 18 AV8 +0.02 11 AV5 -0.05 9

AV3 -0.07 8

AV2 +0.05 7

AV1 +0. 07 135 92 9

AV4 -0.12 6

AV3 -0.09 10 AV8 +0.00 14 AV6 -0. 07 135 94 7

AV6 +0.02 5

AV5 +0.19 7

AV4 -0.05 8

AV3 +0.16 135 96 5

AV7 -0.32 8

AV6+0.05 7

6 AV5 +0.21 AV4 +0.03 9

AV3 +0. 02 10 AV2 -0.05 135 98 4

AV2 +0.23 136 73 10 AV8 +0.02 136 75 6

AV8 -0.16 6

AV1 -0.20 136 77 6

AV4 -0.21 7

AV2 +0. 00 136 79 10 AV6 -0.02 136 83 7

AV8 +0.17 12 AV4 -0.28 7

AV3 -0.09 136 87 13 AV7 -0.05 11 AV6 -0.07 19 AV5 -0.21 8

AV3 -0.09 7

AV2 -0.02 6

AV1 -0.02 136 91 19 AV8 +0.02 18 AV3 -0.05 14 AV2 +0.00 10 AV1 +0.02 136 93 5

AV7 +0.16 6

AV6 +0.02 16 AV5 -0.05 10 AV4 -0.12 136 95 136 99 137 80 137 82 137 84 137 86 137 90 137 92 8

9 8

7 10 6

10 7

6 7

18 14 7

19 6

15 8

11 10 AV7 +0.02 AV6 +0.02 AV4 +0.00 AV1 +0.05 AV7 -0.02 AV8 +0.05 AV8 +0.00 AV6 -0.02 AV7 +0. 02 AV8 +0.02 AV7 +0. 02 AV6 +0.00 AV5 +0.00 AV4 +0. 08 AV3 -0.09 AV2 +0. 05 AV1 +0.05 AV7 +0.21 AV5 -0.05

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVE Wear 1-19%

ROW COL %TW LOCATION 138 85 6

AV2 -0.16 5

AV1 +0.14 10 AV8 -0.14 7

AV7 -0.07 11 AV5 -0.19 7

AV3 -0.11 138 91 6

AV7 +0.17 139 92 12 AV7 -0.21 Total Tubes 2077 Total Records: 5624 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION L-2019-064 Enclosure Page 86 of 89 Page 27 of 27 ROW COL %TW LOCATION

Framatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 54 9

23 AV7 +0.23 63 158 20 AV6 -0.10 26 AV2 +0.02 65 14 23 AV6 -0.03 65 148 20 AV6 -0.10 65 158 23 AV7 +0.14 23 AV6 -0.08 28 AV3 +0.28 23 AV2 +0.02 66 13 26 AV6 +0.02 20 AV3 +0.37 66 153 20 AV6 -0.15 67 14 23 AV6 +0.00 68 157 22 AV6 -0.09 69 14 23 AV3 +0.09 21 AV6 +0.00 69 156 20 AV6 -0.09 73 76 21 AV5 +0.09 74 15 20 AV4 +0.00 74 65 23 AV6 +0.05 76 63 25 AV6 +0.07 20 AV7 +0.07 76 69 28 AV4 +0.03 76 75 22 AV5 +0.07 78 99 26 AV6 -0.02 31 AV5 -0.03 21 AV4 -0.05 79 66 21 AV4 +0.11 79 96 20 AV5 -0.03 79 98 23 AV6 +0.00 79 110 21 AV7 -0.07 22 AV6 -0.05 22 AV5 +0.00 80 77 20 AV5 +0.07 22 AV6 +0.07 81 66 21 AV4 +0.08 26 AV5 +0.05 27 AV6 +0.05 20 AV7 +0.02 82 75 23 AV5 +0.05 22 AV6 +0.07 82 99 28 AV6 -0.02 30 AV5 +0.00 83 66 24 AV5 +0.07 20 AV6 +0.02 83 76 20 AV6 +0.02 83 78 26 AV5 +0.09 22 AV6 +0.07 21 AV7 +0.05 83 84 21 AV6 +0.12 84 73 21 AV4 +0.08 84 75 22 AV5 +0.02 84 77 24 AV6 +0.05 21 AV7 +0. 02 84 105 20 AV6 -0.02 21 AV5 -0.03 85 76 21 AV6 +0.07 85 98 21 AV6 -0.05 85 100 21 AV5 -0.05 86 75 23 AV2 +0.09 27 AV5 +0.07 24 AV6 +0. 07 86 85 20 AV3 +0.10 25 AV4 +0.13 86 89 20 AV6 +0.02 86 97 21 AV3 +0.07 22 AV5 -0.05 20 AV4 -0.05 86 99 20 AV5 -0.03 87 70 21 AV4 +0.03 28 AV5 +0.00 23 AV6 +0. 05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 87 76 25 AV4 +0.05 31 AV5 +0.07 87 80 20 AV5 +0.02 87 82 20 AV5 +0.07 23 AV6 +0. 07 20 AV7 +0.07 87 84 24 AV4 +0.05 24 AV5 +0.05 87 98 20 AV7 -0.05 25 AV6 -0.07 88 71 20 AV5 +0.09 30 AV6 +0.09 20 AV7 +0.07 88 85 21 AV5 +0.09 88 95 24 AV7 -0.05 22 AV6 -0.02 23 AV5 -0.03 88 97 25 AV6 -0.02 27 AV5 -0.03 22 AV3 -0.02 88 99 26 AV6 +0.00 34 AV5 -0.03 24 AV4 -0.02 88 103 26 AV6 -0.02 25 AV5 -0.05 89 74 22 AV7 +0.07 89 82 26 AV3 +0.05 26 AV5 +0.02 23 AV6 +0.05 89 84 29 AV5 +0.02 22 AV6 +0.00 27 AV4 +0.06 89 90 20 AV4 +0.08 21 AV5 +0.09 89 98 20 AV2 +0.00 90 73 21 AV5 +0.07 90 77 24 AV5 +0.10 35 AV6 +0.10 26 AV7 +0.07 90 83 22 AV5 +0.05 90 85 23 AV5 +0.00 34 AV6 +0.00 39 AV7 +0.05 90 97 23 AV8 -0.02 25 AV7 -0.02 30 AV6 -0.02 90 103 22 AV6 +0.00 91 66 26 AV6 +0.00 26 AV4 +0.08 27 AV5 +0.05 91 76 25 AV7 -0.05 30 AV6 -0.02 38 AV5 -0.05 22 AV4 -0.05 21 AV3 -0.02 91 78 20 AV7 -0.09 91 80 20 AV6 -0.05 91 82 22 AV5 -0.08 91 86 20 AV3 +0.00 91 92 20 AV8 -0.05 20 AV7 -0.02 22 AV6 -0.02 27 AV5 -0.03 91 98 20 AV7 -0.05 22 AV6 -0.02 91 100 21 AV4 +0.23 92 77 26 AV7 -0.05 33 AV6 +0.00 26 AV5 +0.02 23 AV4 -0.02 92 79 24 AV6 -0.02 27 AV5 +0.00 L-2019-064 Enclosure Page 87 of 89 Page 1 of 3 ROW COL %TW LOCATION 23 AV4 -0.02 92 81 20 AV7 -0.07 92 83 33 AV5 -0.05 92 85 26 AV7 -0.05 33 AV6 -0.02 24 AV5 +0.00 92 95 21 AV5 +0.00 24 AV4 +0.00 92 97 20 AV6 -0.05 92 99 29 AV6 -0.05 29 AV5 -0.03 20 AV3 +0.02 92 103 22 AV4 +0.10 93 72 20 AV5 +0.07 93 82 24 AV5 -0.11 93 84 24 AV6 -0.07 28 AV5 -0.05 28 AV4 -0.02 93 86 23 AV7 -0.05 20 AV6 -0.02 21 AV5 -0.08 22 AV4 -0.02 93 94 25 AV6 -0.05 24 AV5 +0.02 93 98 32 AV7 -0.02 29 AV6 -0.02 25 AV5 -0.05 23 AV4 -0.05 93 100 25 AV4 +0.10 94 69 21 AV4 +0.13 94 77 24 AV6 -0.05 94 81 23 AV6 -0.07 22 AV4 -0.09 94 83 25 AV6 +0.00 36 AV5 +0. 02 32 AV4 +0. 05 28 AV3 +0.05 94 85 20 AV5 -0.08 29 AV4 -0.07 23 AV3 -0.05 21 AV2 +0.00 94 87 25 AV5 +0.00 24 AV4 -0.02 22 AV3 +0.02 94 91 24 AV6 +0.00 94 95 20 AV4 -0.05 23 AV3 -0.02 27 AV2 -0.02 94 99 22 AV5 +0.02 22 AV4 +0.00 95 64 21 AV7 +0.05 95 66 20 AV4 +0.11 95 78 22 AV5 +0.00 20 AV3 +0.00 95 80 21 AV7 -0.05 25 AV6 -0.02 27 AV5 +0.00 22 AV4 -0.02 95 84 20 AV7 -0.02 32 AV5 +0.00 31 AV4 +0.00 25 AV3 +0. 02 95 86 20 AV7 -0.05 30 AV5 +0.00 26 AV4 +0.00 20 AV3 +0.02 95 88 25 AV7 -0.05 95 92 22 AV5 -0.05 95 96 25 AV6 -0.05 28 AV5 -0.03 23 AV4 +0.00 95 100 20 AV4 +0.05

Frarnatome Inc.

Customer: FPL 09/18 -

EOC23 Plant: St Lucie Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 95 104 30 AV7 +0.07 96 71 26 AV7 +0.07 96 77 24 AV3 +0.00 96 79 25 AV6 -0.02 22 AV5 +0.02 23 AV4 -0.02 96 83 21 AV4 -0.05 96 87 26 AV6 -0.05 96 89 23 AV6 -0.07 96 93 21 AV7 -0.02 26 AV6 -0.02 28 AV5 -0.03 96 97 23 AV6 -0.02 22 AV5 -0.05 96 105 21 AV3 +0.10 97 66 23 AV5 +0.02 26 AV6 +0.02 25 AV7 +0.07 97 76 20 AV7 -0.02 27 AV6 -0.05 36 AV5 +0.00 28 AV4 -0.02 29 AV3 -0.07 97 84 21 AV6 -0.02 24 AV5 -0.05 97 86 30 AV7 -0.05 21 AV5 -0.03 24 AV4 -0.07 22 AV3 -0.05 97 92 23 AV5 -0.03 31 AV4 -0.05 23 AV3 -0.02 97 96 26 AV6 -0.02 97 98 23 AV5 -0.05 97 104 21 AV4 +0.08 20 AV5 +0.05 98 67 20 AV3 +0.12 98 75 24 AV7 -0.05 98 85 21 AV7 -0.05 32 AV4 -0.02 32 AV3 -0.05 27 AV2 +0.00 98 87 26 AV7 -0.05 33 AV6 -0.02 20 AV5 -0.08 98 91 30 AV4 -0.02 98 95 20 AV7 -0.05 98 97 20 AV4 -0.05 98 103 21 AV3 +0.07 98 107 22 AV6 +0.05 99 64 21 AV6 +0.05 26 AV7 +0.07 99 66 29 AV4 +0.14 36 AV5 +0.05 26 AV6 +0.05 99 74 23 AV5 +0.07 22 AV6 +0.07 99 76 21 AV6 -0.05 99 80 21 AV3 +0.02 99 82 27 AV5 -0.13 20 AV4 -0.10 25 AV3 -0.07 99 84 30 AV6 -0.09 33 AV5 -0.08 26 AV4 -0.05 99 86 34 AV7 -0.05 22 AV6 -0.09 23 AV4 +0.00 26 AV3 +0.02 22 AV2 +0.02 99 92 31 AV6 +0.00 29 AV5 +0.00 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 31 AV4 +0.00 30 AV3 +0.07 22 AV2 +0.02 99 96 20 AV6 -0.02 28 AV5 -0.03 27 AV4 -0.07 99 98 23 AV3 +0.07 99 104 20 AV4 +0.05 100 77 25 AV7 -0.02 28 AV6 -0.02 25 AV5 +0.02 26 AV3 +0.00 100 81 21 AV5 -0.05 100 85 24 AV7 -0.05 21 AV6 -0.02 21 AV4 -0.02 100 87 26 AV6 -0.05 29 AV5 -0.05 100 93 21 AV5 -0.03 101 66 20 AV5 +0.05 101 74 23 AV3 +0.05 101 76 25 AV4 -0.02 101 86 21 AV7 -0.05 29 AV5 +0.00 22 AV4 -0.05 101 90 21 AV7 -0.02 101 98 20 AV4 -0.02 21 AV3 +0.02 101 104 28 AV4 +0.05 26 AV5 +0.05 102 75 22 AV7 -0.05 102 81 21 AV6 -0.05 23 AV5 -0.03 20 AV4 -0.02 102 83 25 AV4 -0.10 29 AV5 -0.05 102 85 35 AV7 -0.05 37 AV6 -0.02 25 AV3 +0.00 102 87 32 AV7 -0.07 37 AV6 -0.07 30 AV5 -0.11 102 89 26 AV6 -0.09 28 AV5 -0.05 20 AV4 -0.05 30 AV3 -0.05 24 AV2 -0.04 102 91 31 AV7 -0.02 25 AV6 -0.12 29 AV5 -0.13 102 97 22 AV6 -0.09 20 AV5 -0.03 25 AV4 -0.12 103 84 21 AV7 -0.09 20 AV6 -0.05 26 AV5 -0.05 28 AV3 -0.02 103 86 29 AV5 -0.11 29 AV4 -0.05 103 90 20 AV7 -0.05 103 92 20 AV2 +0.02 104 83 23 AV5 -0.05 25 AV4 -0.07 104 87 24 AV5 -0.05 104 91 24 AV5 -0.03 22 AV4 -0.07 27 AV3 -0.05 104 97 27 AV4 -0.05 105 72 22 AV3 +0.09 23 AV4 +0.13 105 86 21 AV7 -0.05 22 AV6 -0.05 L-2019-064 Enclosure Page 88 of 89 Page 2 of 3 ROW COL %TW LOCATION 29 AV5 -0.05 29 AV4 -0.05 105 96 26 AV5 +0.00 106 83 23 AV4 -0.05 106 85 31 AV7 -0.02 32 AV6 -0.02 23 AV5 -0.08 31 AV3 +0.00 22 AV2 +0.00 106 87 21 AV3 -0.07 106 91 20 AV5 -0.05 106 97 25 AV3 -0.02 20 AV2 -0.05 107 78 21 AV6 -0.02 107 84 28 AV6 -0.07 31 AV5 -0.10 26 AV4 -0.07 107 92 27 AV4 -0.02 29 AV3 +0.00 107 96 20 AV3 +0.02 107 98 25 AV5 -0.05 107 100 20 AV3 +0.12 108 83 30 AV6 -0.07 26 AV5 -0.08 20 AV4 -0.05 20 AV3 +0.00 108 91 27 AV5 +0.02 32 AV4 +0.00 108 95 21 AV3 -0.02 108 99 26 AV6 -0.05 33 AV5 -0.05 21 AV4 +0.00 109 72 22 AV5 +0.05 109 84 23 AV7 -0.07 31 AV5 -0.05 30 AV4 -0.05 109 86 22 AV7 -0.05 28 AV6 -0.05 28 AV5 +0.00 32 AV4 -0.05 109 98 25 AV4 +0.03 27 AV3 +0.05 21 AV2 +0.02 109 100 24 AV6 +0.10 110 83 24 AV5 -0.08 26 AV4 -0.02 110 85 32 AV7 -0.05 34 AV5 -0.11 24 AV4 -0.07 23 AV3 +0.02 110 87 22 AV6 +0.09 110 95 26 AV4 -0.02 110 101 26 AV5 +0.05 111 84 25 AV5 -0.13 25 AV4 -0.02 25 AV3 +0.00 111 86 24 AV7 -0.05 34 AV6 -0.02 26 AV4 -0.07 111 94 25 AV5 +0.00 111 102 20 AV3 +0.02 35 AV5 +0.00 21 AV6 +0.05 21 AV7 +0.05 113 68 26 AV3 +0.10 38 AV4 +0.08 23 AV5 +0.12 113 88 23 AV5 -0.03 114 83 24 AV6 -0.07 33 AV5 -0.03 114 87 24 AV5 -0.03 22 AV4 -0.05

Framatome Inc.

Customer: FPL Plant: St Lucie 09/18 -

EOC23 Bobbin AVB Wear 20-39%

ROW COL %TW LOCATION 24 AV3 -0.05 114 89 20 AV7 -0.05 29 AV6 -0.07 114 99 31 AV5 -0.05 22 AV3 +0.02 115 84 30 AV7 -0.02 26 AV4 -0.02 115 88 24 AVS -0.08 21 AV4 -0.05 115 94 23 AVS +0.00 115 96 20 AV6 -0.02 26 AV4 +0.00 23 AV3 +0.02 116 83 24 AV4 +0.00 116 87 28 AV7 -0.07 24 AV6 -0.02 117 84 22 AV6 -0.07 20 AVS -0.10 117 86 31 AVS +0.00 118 83 31 AVS -0.05 118 87 26 AVS +0.00 25 AV4 -0.05 119 82 20 AV6 -0.02 26 AVS -0.03 119 84 22 AV2 -0.02 119 88 20 AVS -0.08 120 85 28 AV7 -0.07 29 AVS -0.08 24 AV4 -0.05 23 AV3 -0.02 120 91 21 AV6 -0.07 121 84 25 AV6 -0.07 121 88 20 AV6 -0.05 121 90 24 AV4 -0.07 121 100 37 AVS +0.00 20 AV6 +0.05 122 83 24 AV4 -0.05 122 87 28 AV6 -0.05 32 AVS -0.10 33 AV4 -0.02 20 AV3 +0.00 122 103 21 AV3 +0.12 123 84 22 AV7 -0.05 24 AV6 -0.07 20 AV4 -0.05 123 86 21 AVS +0.00 123 90 23 AVS -0.05 29 AV4 -0.07 123 98 22 AV3 +0.00 124 87 25 AVS -0.13 23 AV4 -0.02 124 91 20 AV7 +0.00 125 86 33 AV6 -0.02 24 AVS -0.05 29 AV4 -0.07 22 AV3 -0.05 125 96 21 AV3 +0.05 125 98 20 AV6 -0.02 29 125 102 22 126 103 22 127 86 36 128 53 30 AVS +0. 00 AV4 +0. 08 AVS +0.05 AVS -0.05 AVS +0. 00 128 85 29 AVS -0.05 23 AV3 -0.05 128 103 32 AVS +0.02 129 68 27 AV4 +0.03 129 86 22 AV6 -0.05 23 AV4 -0.07 129 102 24 AV4 +0.05 130 67 28 AV4 +0.11 32 AVS +0.05 Appendix F: Wear <40% at AVBs Unit: 2 Component: S/G B ROW COL %TW LOCATION 34 AV6 +0.05 130 69 20 AVS +0.00 131 70 25 AVS +0.12 131 86 32 AV7 +0.00 26 AV6 +0.02 20 AVS +0.02 25 AV4 +0.00 131 90 21 AV4 -0.07 131 102 22 AV4 +0.03 21 AV6 +0. 05 132 67 34 AV8 +0.07 38 AV4 +0.13 22 AV6 +0.05 24 AV7 +0.05 132 71 28 AV6 +0.02 132 73 27 AVS +0.07 132 91 24 AVS -0.10 133 70 23 AV6 +0.00 133 90 27 AV8 +0.02 133 92 23 AV7 -0.05 133 102 29 AV4 +0.13 21 AVS +0.14 134 91 34 AV8 +0.02 25 AVS -0.08 21 AV4 -0.14 135 82 20 AV7 +0.02 23 AV6 +0.05 23 AVS +0.05 37 AV4 +0.05 32 AV3 +0.02 135 84 24 AV4 -0.07 135 90 25 AV7 -0.02 36 AV6 -0.07 25 AV4 -0.02 135 92 27 AV7 -0.05 27 AVS -0.05 136 83 21 AV6 -0.05 136 87 22 AV4 -0.12 136 91 36 AV7 +0.00 21 AV6 -0.02 22 AVS -0.10 37 AV4 +0.00 138 85 23 AV6 -0.09 26 AV4 -0.19 Total Tubes 277 Total Records: 548 L-2019-064 Enclosure Page 89 of89 Page 3 of 3 ROW COL %TW LOCATION