Text
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-1 WCAP-18660-NP November 2021 Revision 0 APPENDIX C CHARPY V-NOTCH PLOTS FOR EACH CAPSULE INCLUDING BASELINE DATA USING SYMMETRIC HYPERBOLIC TANGENT CURVE-FITTING METHOD METHODOLOGY Contained in Table C-1 are the upper-shelf energy (USE) values that are used as input for the generation of the Charpy V-notch plots using CVGRAPH, Version 6.02. The definition for USE is given in ASTM E185-82 [C-1],
Section 4.18, and reads as follows:
upper shelf energy level - the average energy value for all Charpy specimens (normally three) whose test temperature is above the upper end of the transition region. For specimens tested in sets of three at each test temperature, the set having the highest average may be regarded as defining the upper shelf energy.
Westinghouse reports the average of all Charpy data ( 95% shear) as the USE, excluding any values that are deemed outliers using engineering judgment. Hence, the Capsule N USE values reported in Table C-1 were determined by applying this methodology to the Charpy data tabulated in Table 5-1 through Table 5-5 of this report. USE values documented in Table C-1 for the unirradiated material, as well as for Capsules V, P, R, and S, were also determined by applying the methodology described above to the Charpy impact data reported in WCAP-8086 [C-2] and WCAP-14779 [C-3]. The USE values reported in Table C-1 were used in the generation of the Charpy V-notch curves.
The lower-shelf energy values were fixed at 2.2 ft-lb for all cases. The lower-shelf lateral expansion values were fixed at 1.0 mil to be consistent with the previous capsule analysis. Similarly, the upper-shelf energy must also be fixed for curve-fitting the Charpy V-notch (CVN) Energy data using the values reported in Table C-1.
However, the upper-shelf lateral expansion is not fixed in CVGRAPH. The only exceptions to this in the following graphs are for the Capsules N and V HAZ material, which did have the upper-shelf lateral expansion set to fixed values, because the CVGRAPH software produced artificially high upper-shelf lateral expansion values without setting the value. The fixed lateral expansion values were based on an average of all the lateral expansion values corresponding to greater than or equal to 95% shear.
C.1
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-2 WCAP-18660-NP November 2021 Revision 0 Table C-1 Upper-Shelf Energy Values (ft-lb) Fixed in CVGRAPH(1)
Material Unirradiated Capsule V Capsule P Capsule R Capsule S Capsule N (ft-lb)
(ft-lb)
(ft-lb)
(ft-lb)
(ft-lb)
(ft-lb)
Intermediate Shell Forging C (Tangential Orientation) 158.5 155.1 142.2 145.0 142.5 138.0 Intermediate Shell Forging C (Axial Orientation) 143.1 143.3 136.3 128.7 135.0 119.5 Intermediate Shell to Lower Shell Circumferential Weld -
Seam W3 (Heat # 1752) 82.5 90.0 83.2 75.0 84.5 79.0 Heat Affected Zone (HAZ) Material 211.1(2)
---(3) 143.3 97.3 136.0 105.2 Correlation Monitor Material (CMM) 120.4 91.3 84.8 80.7 82.5 56.8 Notes:
- 1.
These values are calculated as an average of all in-family data points with a shear 95%, consistent with ASTM E185-82 [C-1],
unless otherwise noted.
- 2.
One 95% shear data point (145 ft-lb at 80°F) was considered out-of-family and excluded from the USE calculation.
- 3.
Upper shelf impact energy not obtainable due to excessive toughness per WCAP-14779 [C-3].
CVGRAPH, Version 6.02 plots of all surveillance data are provided in this appendix, on the pages following the reference list.
REFERENCES C-1 ASTM E185-82, Standard Practice for Conducting Surveillance Tests for Light-Water Cooled Nuclear Power Reactor Vessels, American Society for Testing and Materials, 1982.
C-2 Westinghouse Report WCAP-8086, Rev. 0, Northern States Power Co. Prairie Island Unit No. 1 Reactor Vessel Radiation Surveillance Program, June 1973.
C-3 Westinghouse Report WCAP-14779, Rev. 2, Analysis of Capsule S from the Northern States Power Company Prairie Island Unit 1 Reactor Vessel Radiation Surveillance Program, February 1998.
C.2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-3 WCAP-18660-NP November 2021 Revision 0 CVGRAPH VERSION 6.02 INDIVIDUAL PLOTS C.3
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-4 WCAP-18660-NP November 2021 Revision 0 Unirradiated Intermediate Shell Forging C (Tangential)
CV Graph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 9: 12 AM A = 80.35 B = 78.15 C = 91.82 TO= 31.21 D = 0.00 Correlation Coefficient = 0.983 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf Energy = 158.50 (Fixed)
Lower Shelf Energy = 2.20 (Fixed)
Temp@30 ft-lbs=-39.00° F Temp@35 ft-lbs=-29.60° F Temp@50 ft-lbs= -6.40° F Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluenee: 0.00E+000 n/em' 180 160 140 r;,:i 120
~ -
I
¢::
100
- 01) i..
~ = 80
~
z >
60 u
40 o l:::::=:::i:::::::::t:=....---1_.1....-.L....1....__L----J_L...J........L----1.._J_.i,_...L.....L.._J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/29/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-5 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluence: O.OOE+OOO n/cm 2 Unirradiated Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature {° F)
Input CVN Computed CVN Differential
-60 9.0 21.0
-12.05
-60 29.0 210 7.95
-60 11.5 210
-9.55
-30 32.0 34.8
-2.81
-30 16.0 34.8
-1 8.81
-30 28.0 34.8
-6.81
-1 0 63.5 47.5 16.05
-1 0 56.0 47.5 8.55
-1 0 70.0 47.5 22.55 40 89.0
- 87. 8 1.19 40 84.0 87.8
-381 40 860 87.8
-1.81 80 107 0 11 8.4
-11.36 80 115.5 118.4
-2.86 80 111.0 11 8.4
-7.36 150 159.0 147.6 11.43 150 1640 147.6 16.43 210 150.0 155.4
-5.38 210 153.0 155.4
-2.38 210 153.0 155.4
-2.38 300 160.0 158.1 1.95 300 155.0 158.1
-3.05 300 174.0 158.1 15.95 CVGraph 6.02 06/29/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-6 WCAP-18660-NP November 2021 Revision 0 Capsule V Intermediate Shell Forging C (Tangential)
CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 2:40 PM A = 78.65 B = 76.45 C = 76.03 TO = 50.01 D = 0.00 Correlation Coefficient = 0.975 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf Energy = 155.10 (Fixed)
Lower Shelf Energy = 2.20 (Fixed)
Temp@30 ft-lbs= -7.10° F Temp@35 ft-lbs= 0.70° F Temp@50 ft-lbs= 20. 10° F Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/em' 180 160 140 120 100 o l::::=::+/-=:::+/-:::::::c:::::.J._.1....-.L....1....__L----J_L...J........L----1.._J_.i,_...L.....L.._J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CVGrnph 6.02 06/28/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-7 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/cm*
Capsule V Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential
-50 10.0 12.5
-2.47
-25 10.5 20.9
-10.36 0
30.0 34.5
-4.55 0
17.5 34.5
-17.05 25 85.0 54.4 30.63 25 54.5 54.4 0.13 50 84.5 78.6 5.86 75 89.5 102.9
-13.41 150 132.5 144.8
-12.32 210 168.0 152.9 15.14 250 166.0 154.3 11.69 300 154.0 154.9
-0.89 CVGraph 6.02 06/28/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-8 WCAP-18660-NP November 2021 Revision 0 Capsule P Intermediate Shell Forging C (Tangential)
CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 7:29 AM A = 72.20 B = 70.00 C = 89.02 TO = 46.25 D = 0.00 Correlation Coefficient = 0.989 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf Energy = 142.20 (Fixed)
Lower Shelf Energy = 2.20 (Fixed)
Temp@30 ft-lbs=-15.80° F Temp@35 ft-lbs= -6.40° F Temp@50 ft-lbs= 17.10° F Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/em' 160 140 0
120 r;,:i
~ -
100 I
¢::
- 01) 80 i..
~ =
~
z 60 u
40 o l=::I:=::+/-:::::i::.---1.---L._J_.1....-.L....1.......L----1...---1----l-L..i...,_...L.....L..._J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/29/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-9 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/cm*
Capsule P Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential
-50 9.5 16.6
-7.15
-25 17.5 25.7
-8.20
-10 48.5 33.0 15.45 0
44.0 38.8 5.21 25 48.0 55.8
-780 50 74.5 75.1
-0.65 75 970 94.1 2.95 100 106.0 110.0
-3.98 150 129.0 129.8
-0.80 200 1475 1379 9.59 275 136.5 141.4
-4.88 350 142.5 142.0 0.45 CVGraph 6.02 06/29/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-10 WCAP-18660-NP November 2021 Revision 0 Capsule R Intermediate Shell Forging C (Tangential)
CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:05 AM A= 73.60 B = 71.40 C = 103.43 TO = 130.38 D = 0.00 Correlation Coefficient = 0.982 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf Energy = 145.00 (Fixed)
Lower Shelf Energy = 2.20 (Fixed)
Temp@30 ft-lbs= 57.00° F Temp@35 ft-lbs= 67.90° F Temp@S0 ft-lbs= 94.90° F Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/em' 160 140 120 r;,:i
~ -
100 I
¢::
- 01) 80 i..
~ =
~
z 60 u
40 o t:::::=::c=::+/-=:::::c:::C:::.......i._J_.1....-.L....1.......L----1...---1----l-L..i...,_...L.....L..._J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/29/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-11 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/cm*
Capsule R Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential 0
8.0 12.8
-4.82 25 no 18.7
-1.67 50 18.0
- 27. 1
-9.12 50 44.0
- 27. l 16.88 50 10.0 27.1
-17.12 75 52.0 38.7 13.35 150 91.0 87.0 4.01 200 101.0 115.5
-14.52 250 135.0 132.1 2.86 300 149.0 139.8 9.18 350 157.0 143.0 14.01 400 139.0 144.2
-5.23 CVGraph 6.02 06/29/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-12 WCAP-18660-NP November 2021 Revision 0 Capsule S Intermediate Shell Forging C (Tangential)
CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:26 AM A = 72.35 B = 70.15 C = 98.27 TO = 131.23 D = 0.00 Correlation Coefficient = 0.988 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf Energy = 142.50 (Fixed)
Lower Shelf Energy = 2.20 (Fixed)
Temp@30 ft-lbs= 62.60° F Temp@35 ft-lbs= 73.00° F Temp@S0 ft-lbs= 98.80° F Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/em' 160 140 120 r;,:i
~ -
100 I
¢::
- 01) 80 i..
~ =
~
z 60 u
40 o t:::::=::i::::::+/-=:::c:::t:~_J-.1....-.L....1.......L----1...---1----l-L..i...,_...L.....L..._J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/29/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-13 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/cm*
Capsule S Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential
-25 9.0
- 7. 8 1.20 25 10.0 16.7
-6.68 26 33.0 16.9 16.05 72 35.0 34.5 0.46 100 51.0 50.8 0.22 125 68.0 67.9 0.09 150 74.0 85.6
-11.59 175 1060 1017 4.32 250 1360 131.0 4.99 300 150.0 138.1 1188 350 151.0 140.9 10.12 400 133.0 141.9
-8.91 CVGraph 6.02 06/29/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-14 WCAP-18660-NP November 2021 Revision 0 Capsule N Intermediate Shell Forging C (Tangential)
CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/23/2021 5:38 AM A= 70.10 B = 67.90 C = 60.89 TO= 167. 72 D = 0.00 Correlation Coefficient = 0.955 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf Energy = 138.00 (Fixed)
Lower Shelf Energy = 2.20 (Fixed)
Temp@30 ft-lbs= 126.50° F Temp@35 ft-lbs=l32.90° F Temp@50 ft-lbs=149.20° F Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/em' 140 120 100 r;,:i
~ -
I
¢::
80
- 01) i..
~ =
~ 60 z >
u 40 0....____.._.....__.....__....____._.....__.....__....____. __...... _....__...... _..._...... _....... _...... _..._......
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/23/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-15 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/cm*
Capsule N Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential 77 24.3 8.8 15.53 90 9.8 12.0
-2.21 110 6.5 19.9
-1 3.43 120 33.5 25.6 7.86 130 55.8 32.7
- 23. 10 140 43.0 41.2 1.84 150 19.0 50.9
-31. 88 160 68.0 61.5 6.46 180 84.0 83.6 0.39 200 106.0 103.1 2.94 250 138.0 129.5 8.53 300 138.0 136.3 1.74 CVGraph 6.02 06/23/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-16 WCAP-18660-NP November 2021 Revision 0 Unirradiated Intermediate Shell Forging C (Tangential)
Plant: Prairie Island 1 Orientation: Tangential 120 100 r,J -....
E 80
'-" =
0....
r,J =
~
Q.
60 Jl"!i
~ -
~ - 40
~..
~
~
20 CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 l 1 :14 AM A= 48.18 B = 47.18 C = 65.16 TO= -5.22 D = 0.00 Correlation Coefficient= 0.970 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf L.E. = 95.36 Lower Shelf L.E. = 1.00 (Fixed)
Temp@35 mils=-23.90° F Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluence: O.OOE+OOO n/em' 0 l:::::::===:::::::t:::=L.....L.----1._L_....1...---l._..1...-....L----1._..L..__,____J_..,__.....L___,Ji..........J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/29/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-17 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluence: O.OOE+OOO n/cm 2 Unirradiated Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature {° F)
Input L. E.
Computed L. E.
Differential
-60 n o 15.8
-4.81
-60 29.0 15.8 13.19
-60 10.0 15.8
-5.81
-30 270 31.1
-4.06
-30 14.0 31.1
-17.06
-30 23.0 31.1
-8.06
-1 0 56.0 44.7 11.28
-1 0 470 44.7 2.28
-1 0 610 44.7 18.28 40 760 76.5
-0.51 40 710 76.5
-5.51 40 74.0 76.5
-2.51 80 81.0 88.9
-7.93 80 88.0 88.9
-0.93 80 87 0 88.9
-1.93 150 102.0 94.6 7.44 150 101.0 94.6 6.44 210 99.0 95.2 3.77 210 98.0 95.2 2.77 210 95.0 95.2
-0.23 300 98.0 95.4 2.65 300 90.0 95.4
-5.35 300 89.0 95.4
-6.35 CVGraph 6.02 06/29/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-18 WCAP-18660-NP November 2021 Revision 0 Capsule V Intermediate Shell Forging C (Tangential)
Plant: Prairie Island 1 Orientation: Tangential CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 2:45 PM A = 40.52 B = 39.52 C = 46.30 TO = 25.46 D = 0.00 Correlation Coefficient = 0.949 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf L.E. = 80.04 Lower Shelf L.E. = 1.00 (Fixed)
Temp@35 mils= 19.00° F Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/em' r,J = 70---------------- ---------------------
E 0 l::::::::::::c:::::::+/-==::i:=::t:::::....1....---L----11....--.l..,_.....1...---1_.1....-...L.....1..._.l_.i...,_...L----1..__J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CVGrnph 6.02 06/28/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-19 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/cm*
Capsule V Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F)
Input L. E.
Computed L. E.
Differential
-50 5.5 3.9 1.58
-25 4.0 9.0
-5.03 0
21.0 20.7 0.26 0
9.5 20.7
-1 1.24 25 61.5
- 40. 1 21.37 25 35.5
- 40. 1
-4.63 50 55.5 59.7
-4.20 75 62.5 71.7
-9.22 150 67.0 79.7
-12.68 210 86.5 80.0 6.48 250 94.5 80.0 14.46 300 78.0 80.0
-2.04 CVGraph 6.02 06/28/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-20 WCAP-18660-NP November 2021 Revision 0 Capsule P Intermediate Shell Forging C (Tangential)
Plant: Prairie Island 1 Orientation: Tangential CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 4:06 PM A = 44.52 B = 43.52 C = 88.50 TO = 29.08 D = 0.00 Correlation Coefficient = 0.967 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf L.E. = 88.04 Lower Shelf L.E. = 1.00 (Fixed)
Temp@35 mils= 9.50° F Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/em' o l::::::::::::c:::::=::::t::~---1___::i:....__L_....1....__L----J_L...J........L----1.._J_.i,_...L.....L.._J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CVGrnph 6.02 06/28/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-21 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/cm*
Capsule P Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F)
Input L. E.
Computed L. E.
Differential
-50 3.1 13.5
-1 0.39
-25 15.7 20.8
-5 11
-10 34.6 26.5
- 8. 14 0
35.8 30.7 5.08 25 37 0 42.5
-5.52 50 66.9 54.6 12.28 75 53.9 65.3
-11.37 100 76.8 73.5 3.35 150 73.2 82.7
-9.53 200 90.6 86.3 4.35 275 89.4 87.7 1.69 350 90.2 88.0 2.22 CVGraph 6.02 06/28/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-22 WCAP-18660-NP November 2021 Revision 0 Capsule R Intermediate Shell Forging C (Tangential)
Plant: Prairie Island 1 Orientation: Tangential
~ -*-
CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/202 1 8:07 AM A= 40.14 B = 39.14 C = 88.29 TO= 92.60 D = 0.00 Correlation Coefficient = 0.978 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf L.E. = 79.29 Lower Shelf L.E. = 1.00 (Fixed)
Temp@35 mils= 81.00° F Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/em' 8 60 t----+----+----+----+---#--+----+----+----+------t
=
0
- 50 l-------,f------4----+----+--l----+-----+----+----+-----I
=
~
Q.
~ 40 1--~-+-----:--+--~-+--i3-ft---+-~-+----+--~-+-----I
~
o l::::::::::i::::::+/-::::I:::::Jc..._.L...-...L....i...---1_.1....-.L....i...---1----J1....-L....i.........L----1._J
-300
-200
-100 0
100 200 300 400 500 600 Temperature (° F)
CV Graph 6.02 06/29/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-23 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/cm*
Capsule R Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F)
Input L. E.
Computed L. E.
Differential 0
8.0 9.6
-1.56 25 14.0 14.9
-0.92 50 15.0 22.6
-760 50 34.0 22.6 11.40 50 130 22.6
-9.60 75 40.0 32.4 7.55 150 63.0 62.5 0.47 200 66.0 730
-6.97 250 80.0 77.1 2.86 300 78.0 78.6
-0.58 350 76.0 79.1
-3.06 400 85.0 79.2 5.78 CVGraph 6.02 06/29/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-24 WCAP-18660-NP November 2021 Revision 0 Capsule S Intermediate Shell Forging C (Tangential)
Plant: Prairie Island 1 Orientation: Tangential CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:28 AM A= 46.43 B = 45.43 C = 104.38 TO = 115.05 D = 0.00 Correlation Coefficient = 0.982 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf L.E. = 91.86 Lower Shelf L.E. = 1.00 (Fixed)
Temp@35 mils= 88.30° F Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/em' o l::::::::i::::::::::l:==:c=::J::.._.1....--.1-....1....__1.----J_L...J........L----1.._J_.i,_...L.....L.._J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/29/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-25 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/cm*
Capsule S Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F)
Input L. E.
Computed L. E.
Differential
-25 4.0 6.8
-2.81 25 10.0 14.7
-4.74 26 26.0 15.0 1104 72 29.0 28.7 0.31 100 37.0 39.9
-2.93 125 51.0 50.7 0.25 150 54.0 61.1
-7.10 175 n o 70.0 7.01 250 93.0 85.5 7.50 300 80.0 89.3
-9.31 350 90.0 90.9
-0.86 400 94.0 915 2.52 CVGraph 6.02 06/29/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-26 WCAP-18660-NP November 2021 Revision 0 Capsule N Intermediate Shell Forging C (Tangential)
Plant: Prairie Island 1 Orientation: Tangential r,J -....
E
'-" =
0....
r,J =
~
Q.
Jl"!i
~ -
~ -
~..
~
~
110 100 90 80 --
70 60 so 40 30 20 10 0
-300 CV Graph 6.02
-200 CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/23/2021 5:54 AM A= 50.85 B = 49.85 C = 79.67 TO= 167.12 D = 0.00 Correlation Coefficient = 0.955 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper ShelfL.E. = 100.69 Lower Shelf L.E. = LOO (Fixed)
Temp'.@35 mils=140.90° F Material: SA508CL3 Capsule: N
/ t cl
</ J nl 1
" 7_
- I -
j,
_/
V r--
Heat: 21918/38566 Fluence: 8.45E+019 n/em'
-100 0
100 200 300 400 500 600 Temperature{° F) 06/23/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-27 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/cm*
Capsule N Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F)
Input L. E.
Computed L. E.
Differential 77 20.0 104 9.60 90 11.0 13.6
-2.57 110 9.0 20.2
-11.1 9 120 29.5 244 5.12 130 41.0 29.2 11.83 140 36.0 34.5 149 150 20.0 40.3
-20.30 160 49.5 464 3.09 180 64.5 58.8 5.66 200 72.5 70.3 2.17 250 87.5 89.6
-2.13 300 97.5 97.3 0.23 CVGraph 6.02 06/23/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-28 WCAP-18660-NP November 2021 Revision 0 Unirradiated Intermediate Shell Forging C (Tangential)
CV Graph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 9: 13 AM A = 50.00 B = 50.00 C = 93.52 TO = 35.80 D = 0.00 Correlation Coefficient = 0.987 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)
Lower Shelf %Shear = 0.00 (Fixed)
Plant: Prairie Island 1 Orientation: Tangential 100
~
Temperature at 50% Shear = 35.90 Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluenee: 0.00E+000 n/em'
~
60 ----+----+----+--
~
-+----+----+----+----+-----'I QJ
.c
- 00.
50 1------1----+----+--l'-------+----1------+-----+----1
=
QJ CJ
~
40 -----+----+------------------------------
~
0 L.-....i..-111:::::::;;.i__.1.........1.._..L........J.-..L...---L-..L...---L-...L..----I-....L...-L...-....L..-l..-...J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/29/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-29 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluence: O.OOE+OOO n/cm 2 Unirradiated Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature {° F)
Input %Shear Computed %Shear Differential
-60 9.0 11.4
-2.42
-60 18.0 11.4 6.58
-60 120 11.4 0.58
-30 25.0 19.7 5.33
-30 no 19.7
-6.67
-30 18.0 19.7
-1.67
-1 0 34.0 27.3 6.70
-1 0 25.0 27.3
-2.30
-1 0 30.0 27.3 2.70 40 63.0 52.2 10.75 40 45.0 52.2
-7.25 40 45.0 52.2
-7.25 80 79.0 720 6.98 80 67.0 720
-5.02 80 61.0 720
-11.02 150 100.0 92.0 8.00 150 1000 920 8.00 210 1000 97.6 2.35 210 1000 97.6 2.35 210 100.0 97.6 2.35 300 100.0 99.6 0.35 300 100.0 99.6 0.35 300 100.0 99.6 0.35 CVGraph 6.02 06/29/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-30 WCAP-18660-NP November 2021 Revision 0 Capsule V Intermediate Shell Forging C (Tangential)
CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 2:44 PM A = 50.00 B = 50.00 C = 71.38 TO = 75.91 D = 0.00 Correlation Coefficient = 0.989 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)
Lower Shelf %Shear = 0.00 (Fixed)
Plant: Prairie Island 1 Orientation: Tangential 100
~
Temperature at 50% Shear= 76.00 Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/em'
~
60 ----+----+----+-------<t+----+----+-----+-----+-----'I QJ
.c
- 00.
501------1----+----+----+-----+----1------+-----+----1
=
QJ CJ
~
40 ----~---+----1---IE-'1-4----1----~---+----1----1
~
0 L..-....L.-..L......... ~-;;;.......... ---1_....i..._.i.........1,,_....i...._.i.,_....1._..i..._1....-....1.,_..i....---1-....1
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/28/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-31 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/cm*
Capsule V Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F)
Input %Shear Computed %Shear Differential
-50 2.0 2.9
-0.85
-25 5.0 5.6
-0.59 0
10.0 10.6
-0.65 0
20.0 10.6 9.35 25 30.0 19.4 10.64 25 15.0 19.4
-4.36 50 30.0 32.6
-2.61 75 40.0 49.4
-9.36 150 100 0 88.9 1114 210 100.0 97.7 2.28 250 100.0 99.2 0.76 300 100.0 99.8 0.19 CVGraph 6.02 06/28/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-32 WCAP-18660-NP November 2021 Revision 0 Capsule P Intermediate Shell Forging C (Tangential)
CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 4:04 PM A= 50.00 B = 50.00 C = 92.34 TO= 74.14 D = 0.00 Correlation Coefficient = 0.996 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)
Lower Shelf %Shear = 0.00 (Fixed)
Plant: Prairie Island 1 Orientation: Tangential 100
~
Temperature at 50% Shear = 74.20 Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/em'
~
60 ----+----+----+---- -------------------
QJ
.c
- 00.
501------1----+------~ ----+----1------+-----+----1
=
QJ CJ
~
40 -----+----+------ ---------------------
~
0 L-....l..-"---=C::;;...L.........1..-..L........J.-..L...---L-..L...---L-...L..----I-....L...-L...-....L..-l..-...J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/28/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-33 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/cm*
Capsule P Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F)
Input %Shear Computed %Shear Differential
-50 3.0 6.4
-3.36
-25 7.0 10.5
-3.46
-10 18.0 13.9 4.09 0
17.0 16.7 0.28 25 28.0 25.6 2.35 50 34.0 37.2
-3.22 75 53.0 50.5 2.53 100 640 63.6 0.35 150 78.0 83.8
-5.79 200 100.0 93.9 6.15 275 100.0 98.7 1.27 350 100.0 99.7 0.25 CVGraph 6.02 06/28/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-34 WCAP-18660-NP November 2021 Revision 0 Capsule R Intermediate Shell Forging C (Tangential)
CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:06 AM A = 50.00 B = 50.00 C = 90.55 TO = 131.34 D = 0.00 Correlation Coefficient = 0.995 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)
Lower Shelf %Shear = 0.00 (Fixed)
Plant: Prairie Island 1 Orientation: Tangential 100
~
Temperature at 50% Shear= 131.40 Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/em'
~
60 ----+---+----+----+--+--+----+----+----+-----'I QJ
.c
- 00.
50 1------1----+----+-------+---+----1------+-----+----1
=
QJ CJ
~
40 -----+----+-------- -------------------
~
0 L-....L..-J...........1.-111=::::::;;.,.._%.,.......J._..J.........J._..L...---L-...L..----I-....L...-L...-....L..-l..-...J
-300
-200
-100 0
100 200 300 400 500 600 Temperature{° F)
CV Graph 6.02 06/29/2021 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-35 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/cm*
Capsule R Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F)
Input %Shear Computed %Shear Differential 0
2.0 5.2
-3.21 25 6.0 8.7
-2.72 50 14.0 14.2
-0.23 50 18.0 14.2 3.77 50 110 14.2
-3.23 75 30.0 22.4 7.63 150 54.0 60.2
-6.16 200 82.0 82.0 000 250 100 0 93.2 6.78 300 100.0 97.6 2.35 350 100.0 99.2 0.79 400 100.0 99.7 0.26 CVGraph 6.02 06/29/2021 Page 2/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-36 WCAP-18660-NP November 2021 Revision 0 Capsule S Intermediate Shell Forging C (Tangential)
CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:27 AM A = 50.00 B = 50.00 C = 71.03 TO = 161.20 D = 0.00 Correlation Coefficient = 0.996 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)
Lower Shelf %Shear = 0.00 (Fixed)
Plant: Prairie Island 1 Orientation: Tangential 100 90 80 70
~
~
60 QJ
.c
- 00.
50
=
QJ CJ
~
40 QJ
~
30 20 10 0
-300
-200 CV Graph 6.02
-100 Temperature at 50% Shear= 161.20 0
0 Material: SA508CL3 Capsule: S 100 200 Temperature{° F) 06/29/2021 300 Heat: 21918/38566 Fluence: 4.39E+019 n/em' 400 500 600 Page 1/2
- This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)
Westinghouse Non-Proprietary Class 3 C-37 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/cm*
Capsule S Intermediate Shell Forging C (Tangential)
Charpy V-Notch Data Temperature (0 F)
Input %Shear Computed %Shear Differential
-25 5.0 0.5 4.47 25 5.0 2.1 2.89 26 10.0 2.2 7.83 72 10.0 7.5 2.50 100 15.0 15.1
-0.15 125 30.0 26.5 3.48 150 35.0 42.2
-7.18 175 60.0 59.6 0.41 250 100 0 92.4 7.58 300 100.0 98.0 1.97 350 100.0 99.5 0.49 400 100.0 99.9 0.12 CVGraph 6.02 06/29/2021 Page 2/2