WCAP-18660-NP, Revision 0, Analysis of Capsule N from the Xcel Energy Prairie Island Unit 1 Reactor Vessel Radiation Surveillance Program, Appendix C, Part 2
ML22067A152
Person / Time
Site: Prairie Island  
(DPR-042)
Issue date: 11/30/2021
From: Benson R, Long M, Mays B
Westinghouse
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22067A147 List:
References
L-PI-22-005 WCAP-18660-NP, Rev 0
Download: ML22067A152 (37)


Text

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-38 WCAP-18660-NP November 2021 Revision 0 Capsule N Intermediate Shell Forging C (Tangential)

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/23/2021 5:48 AM A= 50.00 B = 50.00 C = 62.93 TO= 168.14 D = 0.00 Correlation Coefficient = 0.992 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear = 0.00 (Fixed)

Plant: Prairie Island 1 Orientation: Tangential 100

~

Temperature at 50% Shear= 168.20 Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/em'

~

60 ----+----+----+----+-----+fl>-+----+-----+-----+-----'I QJ

.c

00.

50 1------1----+----+------------r------+-----+----1

=

QJ CJ

~

40 ----~---+----1------1----..:1>--l----~---+----1----1

~

0 L..-....L.-..L....---JL...-....L..-"""----=:;;....L..-.L.........1.-....L...-.1..-....L.-..L....-L...-....L..-"""-----1-....1

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/23/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-39 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Tangential Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/cm*

Capsule N Intermediate Shell Forging C (Tangential)

Charpy V-Notch Data Temperature (0 F)

Input %Shear Computed %Shear Differential 77 10.0 5.2 4.77 90 10.0 7.7 2.30 110 15.0 13.6 1.39 120 20.0 17 8 2.20 130 30.0 22.9 7.07 140 25.0 29.0

-4.02 150 30.0 36.0

-5.97 160 40.0 43.6

-3.57 180 60.0 59.3 0.68 200 75.0 73.4 1.65 250 100.0 93.1 6.90 300 100.0 98.5 1.49 CVGraph 6.02 06/23/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-40 WCAP-18660-NP November 2021 Revision 0 U nirradiated Intermediate Shell Forging C (Axial)

CV Graph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 9: 18 AM A = 72.65 B = 70.45 C = 95.50 TO = 35.92 D = 0.00 Correlation Coefficient = 0.979 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf Energy = 143. 10 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs=-31.00° F Temp@35ft-lbs=-21.()0° F Temp@50 ft-lbs= 4.10° F Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluenee: 0.00E+000 n/cm' 160 140 120 r;,:i

~ -

100 I

¢::

01) 80 i..

~ =

~

z 60 u

40 o ~:::c::=::t:::.i....---1.---L._J_.1....-.L....1.......L----1...---1----l-L..i...,_...L.....L..._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-41 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluence: O.OOE+OOO n/cm 2 U nirradiated Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature {° F)

Input CVN Computed CVN Differential

-60 6.5 18.9

-12.37

-60 120 18.9

-6.87

-60 65 18.9

-1 2.37

-30 32.0 30.5 1.49

-30 53.0 30.5 22.49

-30 10.0 30.5

-20.51

-1 0 41.0 41.2

-0.17

-1 0 43.0 41.2 1.83

-1 0 40.0 41.2

-1.17 10 69.0 54.0 15.01 10 53.0 54.0

-0.99 10 70.5 54.0 16.51 40 76.0 75.7 0.34 40 66.5 75.7

-9.16 80 110.0 103.0 6.96 80 90.5 103.0

-12.54 80 97 0 103.0

-6.04 210 141.0 139.5 1.48 210 134.5 139.5

-5.02 210 1460 139.5 6.48 300 149.0 142.5 6.46 300 148.0 142.5 5.46 300 140.0 142.5

-2.54 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-42 WCAP-18660-NP November 2021 Revision 0 Capsule V Intermediate Shell Forging C (Axial)

CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 2:48 PM A = 72. 75 B = 70.55 C = 72. 79 TO = 68.90 D = 0.00 Correlation Coefficient = 0.954 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf Energy = 143.30 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs= 17.80° F Temp@35 ft-lbs= 25.50° F Temp@50 ft-lbs= 44.60° F Plant: Prairie Island 1 Orientation: Axial 160 140 120 r;,:i

~ -

100 I

¢::

01) 80 i..

~ =

~

z 60 u

40 Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/cm' o t:::::::+/-:::::+/-::::::::I:::::J:.._.1....--.1-....1....__1.----J_L...J........L----1.._J_.i,_...L.....L.._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/28/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-43 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/cm*

Capsule V Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential

-25 130 12.l 0.86 0

19.0 20.7

-1.67 0

53.0 20.7 32.33 25 10.0 34.7

-24.71 50 78.5 54.8 23.66 50 30.5 54.8

-24.34 75 78.0 78.7

-0.65 120 124.5 115.5 9.02 150 126.5 129.6

-3.08 210 140.0 140.4

-0.44 300 140.0 143.1

-3.05 300 150.0 143.1 6.95 CVGraph 6.02 06/28/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-44 WCAP-18660-NP November 2021 Revision 0 Capsule P Intermediate Shell Forging C (Axial)

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 7:37 AM A= 69.25 B = 67.05 C = 137.57 TO= 95.10 D = 0.00 Correlation Coefficient = 0.967 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf Energy = 136.30 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs= 2.90° F Temp@35 ft-lbs= 17.60° F Temp@50 ft-lbs= 54.50° F Plant: Prairie Island 1 Orientation: Axial 160 140 120 r;,:i

~ -

100 I

¢::

01) 80 i..

~ =

~

z 60 u

40 0

Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/cm' 0....____.._.....__.....__....____._.....__.....__....____. __...... _....__...... _..._...... _....... _...... _..._......

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-45 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/cm*

Capsule P Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential

-50 6.0 16.7

-1 0.71

-1 0 18.5 26.1

-7.61 0

40.0

29. 1 10.90 50 58.5 48.0 104 8 75 70.0 59.5 1048 100 55.0 71.6

-1 6.64 150 910 94.7

-3.67 200 103.0 112.3

-9.33 250 146.0 123.5 2246 350 125.5 133.1

-7.58 400 137.5 134.7 2.77 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-46 WCAP-18660-NP November 2021 Revision 0 Capsule R Intermediate Shell Forging C (Axial)

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:09 AM A= 65.45 B = 63.25 C = 121.18 TO= 129. 73 D = 0.00 Correlation Coefficient = 0.947 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf Energy = 128.70 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs= 53.00° F Temp@35 ft-lbs= 66.20° F Temp@50 ft-lbs= 99.60° F Plant: Prairie Island 1 Orientation: Axial 140 120 100 r;,:i

~ -

I

¢::

80

01) i..

~ =

~ 60 z >

u 40 Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/cm' 0....____.._.....__.....__....____._.....__.....__....____. __...... _....__...... _..._...... _....... _...... _..._......

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-47 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/cm*

Capsule R Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential 0

11.0 15.5

-4.50 25 9.0 21.3

-1 2.27 50 36.0 29.0 7.04 50 18.0 29.0

-1 0.96 75 75.0 38.7 36.32 75 42.0 38.7 3.32 100 44.0 50.2

-6.24 150 51.0 75.9

-24.93 200 101.0 98.5 2.50 250 124.0 113.4 10.58 300 129.0 121.5 7.48 400 133.0 127.3 5.75 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-48 WCAP-18660-NP November 2021 Revision 0 Capsule S Intermediate Shell Forging C (Axial)

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:30 AM A= 68.60 B = 66.40 C = 100.40 TO = 109.64 D = 0.00 Correlation Coefficient = 0.976 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf Energy = 135.00 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs= 43.00° F Temp@35 ft-lbs= 53.70° F Temp@50 ft-lbs= 80.80° F Plant: Prairie Island 1 Orientation: Axial 140 120 100 r;,:i

~ -

I

¢::

80

01) i..

~ =

~ 60 z >

u 40 Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/cm' 0....____.._.....__.....__....____._.....__.....__....____. __...... _....__...... _..._...... _....... _...... _..._......

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-49 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/cm*

Capsule S Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential

-25 7.0 10.7

-3.70 25 22.0 23.0

-0.96 50 19.0 33.2

-1 4.22 60 49.0 38.2 10.79 72 63.0 44.8

18. 19 100 59.0 62.2

-3.24 125 69.0 78.7

-9.68 175 970 106.6

-9.60 225 135.0 122.9

12. 12 250 138.0 127.4 10.64 300 132.0 132.1

-0.07 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-50 WCAP-18660-NP November 2021 Revision 0 Capsule N Intermediate Shell Forging C (Axial)

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/23/2021 6:02 AM A= 60.85 B = 58.65 C = 87.65 TO= 167. 71 D = 0.00 Correlation Coefficient = 0.877 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf Energy = 119.50 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs=! 16.50° F Temp@35 ft-lbs=l26.30° F Temp@50 ft-lbs=! 51.40° F Plant: Prairie Island 1 Orientation: Axial 140 120 100 r;,:i

~ -

I

¢::

80

01) i..

~ =

~ 60 z >

u 40 Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/cm' 0....____.._.....__.....__....____._.....__.....__....____. __...... _....__...... _..._...... _....... _...... _..._......

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/23/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-51 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/cm*

Capsule N Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F) lnputCVN Computed CVN Differential 60 17.8 11.5 6.35 77 21.5 15.3

6. 15 90 26.0 19.2 6.77 100 130 22.8

-9.82 110 45.5 270 18.51 130 55.5 37.1 18.43 160 35.5 55.7

-20.21 170 17.5 62.4

-44.89 180 715 69.0 2.48 200 110.0 81.5 28.47 250 118.5 103.9 14.56 300 120.5 114.0 6.46 CVGraph 6.02 06/23/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-52 WCAP-18660-NP November 2021 Revision 0 U nirradiated Intermediate Shell Forging C (Axial)

Plant: Prairie Island 1 Orientation: Axial CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 9:21 AM A= 48.33 B = 47.33 C = 79.08 TO= 9.99 D = 0.00 Correlation Coefficient = 0.976 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf L.E. = 95.67 Lower Shelf L.E. = 1.00 (Fixed)

Temp@35 mils=-1 2.90° F Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluenee: O.OOE+OOO n/cm' 0 l=::::i::::::::t::::::.i._L_....1....___l.----11....--.l..,_.....1...---1_.1....-...L.....1..._.l_.i...,_...L----1..__J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-53 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluence: O.OOE+OOO n/cm 2 U nirradiated Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature {° F)

Input L. E.

Computed L. E.

Differential

-60 7 0 14.8

-7.78

-60 no 14.8

-1.78

-60 70 14.8

-7.78

-30 26.0 26.2

-0.25

-30 44.0 26.2 17.75

-30 no 26.2

-1325

-1 0 35.0 36.6

-1.61

-1 0 370 36.6 0.39

-1 0 35.0 36.6

-1.61 10 61.0 48.3 1266 10 45.0 48.3

-3.34 10 59.0 48.3 10.66 40 66.0 65.5 0.52 40 56.0 65.5

-9.48 80 82.0 81.9

0. 11 80 76.0 81.9

-5.89 80 79.0 81.9

-2.89 210 97 0 95.1 1.93 210 94.0 95.1

-1.07 210 96.0 95.1 0.93 300 960 95.6 0.40 300 970 95.6 1.40 300 98.0 95.6 2.40 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-54 WCAP-18660-NP November 2021 Revision 0 Capsule V Intermediate Shell Forging C (Axial)

Plant: Prairie Island 1 Orientation: Axial

~ -*-

CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 2:51 PM A = 43. 73 B = 42. 73 C = 79.58 TO = 64.48 D = 0.00 Correlation Coefficient = 0.938 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf L.E. = 86.47 Lower Shelf L.E. = 1.00 (Fixed)

Temp@35 mils= 48.00° F Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/cm' 8 60 t----+----+----+----111----+----+----+----+------t

=

0

  • 50 l-------,f------4----+---------+-----+----+----+-----I

=

~

Q.

~ 40 1--~-+-----:--+--~-+--tt3-i---+-~-+----+--~-+-----I

~

o l:::::::::::i=:::+/-::=:c:::::::::JL_.L...-...L....i...---1_.1....-.L....i...---1----J1....-L....i.........L----1._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/28/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-55 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/cm*

Capsule V Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input L. E.

Computed L. E.

Differential

-25 6.0 9.2

-3.16 0

14.5 15.1

-0.61 0

34.5 15.1 19.39 25 7.5 24.1

-1 6.62 50 56.0 36.0 19.96 50 25.0 36.0

-11.04 75 40.0 49.3

-9.35 120 74.5 69.5 5.00 150 81.0 77.5 3.46 210 84.0 84.3

-0.32 300 88.0 86.2 1.76 300 81.0 86.2

-5.24 CVGraph 6.02 06/28/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-56 WCAP-18660-NP November 2021 Revision 0 Capsule P Intermediate Shell Forging C (Axial)

Plant: Prairie Island 1 Orientation: Axial 60

~ -*-8

._, 50

=

0 *-

~ =

~

Q. 40

~

~ -

~

30 aJ..

~

~ 20 CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 7:41 AM A= 31.48 B = 30.48 C = 74.48 TO = 9.65 D = 0.00 Correlation Coefficient = 0.935 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf L.E. = 61.97 Lower Shelf L.E. = 1.00 (Fixed)

Temp@35 mils= 18.30° F Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/cm' o l:::::::::::::i==t::=::i:~L_..i_...L....i...---1_.1....-.L....i...---1----J1....-L....i.........L----1._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-57 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/cm*

Capsule P Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input L. E.

Computed L. E.

Differential

-50 12.2 112 0.97

-1 0 15.7 23.6

-7.92 0

31.5 27.6 3.95 50 55.1 46.5 8.55 75 53.1 53.0 0.12 100 47.2 57.0

-9.81 150 51.6 60.6

-8.99 200 65.7 61.6 4.10 250 73.2 61.9 11.33 350 63.8 62.0 1.84 400 57.1 62.0

-4.86 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-58 WCAP-18660-NP November 2021 Revision 0 Capsule R Intermediate Shell Forging C (Axial)

Plant: Prairie Island 1 Orientation: Axial

~ -*-

CV Graph 6.02: Hyperbolic Tangent Curve Printed on 6/29/202 1 8: 12 AM A= 43.15 B = 42.15 C = 130.11 TO= 110. 72 D = 0.00 Correlation Coefficient = 0.944 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf L.E. = 85.30 Lower Shelf L.E. = 1.00 (Fixed)

Temp@35 mils= 85.30° F Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/cm' 8 60 t----+----+----+----+-------,f-+----+----+----+------t

=

0

  • 50 l-------,f------4----+-----+--l'---+-----+----+----+-----I

=

~

Q.

~ 40 t-----+------,t-----+-----1~---+-----+---+-----+------I

~

o l=:+/-=:::t::=:i:....---1..___i._L_..i_...L---'----1.____i_L_..1...--..L....i....---1.----1._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-59 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/cm*

Capsule R Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input L. E.

Computed L. E.

Differential 0

10.0 14.0

-4.00 25 10.0 18.8

-8.81 50 31.0 24.8 6.20 50 16.0 24.8

-8.80 75 55.5 31.9 23.64 75 31.0 31.9

-0.86 100 36.0 39.7

-3.69 150 46.0 55.5

-9.50 200 67.0 68.3

-125 250 83.0 76.4 6.56 300 79.0 80.9

-1.94 400 84.0 84.3

-0.33 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-60 WCAP-18660-NP November 2021 Revision 0 Capsule S Intermediate Shell Forging C (Axial)

Plant: Prairie Island 1 Orientation: Axial r,;,. -...

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/202 1 8:33 AM A= 41.02 B = 40.02 C = 86.00 TO= 88.03 D = 0.00 Correlation Coefficient = 0.959 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf L.E. = 81.04 Lower Shelf L.E. = 1.00 (Fixed)

Temp@35 mils= 75.00° F Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/cm' e 60 - ------------- --------------

-=

0

-~ 50 t--,-----,f------t----:---+----tt'H---+----,--+----+---,--t-----1

=

~

0.

~ 40 ------+-----+-----+---11-+-----+-----+-----+-----+-----.1

~

o l:::::::::::c::::::::l::::::::::::c:::=:::lC.....~'....L....i...---1_.1....-.L....L...--1..----J1....-L....i.........L----1._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-61 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/cm*

Capsule S Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input L. E.

Computed L. E.

Differential

-25 2.0 6.4

-4.39 25 14.0 16.0

-2.01 50 14.0 24.4

-10.39 60 36.0 28.4 7.58 72 45.0 33.6 11.36 100 46.0 46.6

-0.55 125 50.0 57.2

-7.24 175 66.0 71.7

-5.69 225 90.0 77.9 1214 250 85.0 79.2 5.77 300 70.0 80.5

-1 0.47 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-62 WCAP-18660-NP November 2021 Revision 0 Capsule N Intermediate Shell Forging C (Axial)

Plant: Prairie Island 1 Orientation: Axial CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/23/2021 6:07 AM A= 50.58 B = 49.58 C = 127.22 TO = 180.22 D = 0.00 Correlation Coefficient = 0.870 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper ShelfL.E. = 100.16 Lower Shelf L.E. = LOO (Fixed)

Temp'.@35 mils=138.90° F Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/cm' 110 -----------....... --....... --------------....... ---

100

~ 80 t-----,,---t----:---+----:---+---+----+-~.H---'f-----t----+----:---~

5 70 t----+----+-----+---------------1-----+-----t

=

0 o 6=:::c::::::l::::::=:c:=:!=-.1....-.L....1....__L----J_L...J........L----1.._J_.i,_...L.....L.._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/23/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-63 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/cm*

Capsule N Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input L. E.

Computed L. E.

Differential 60 14.0 14.0

-0.02 77 20.0 17.3 2.65 90 23.0 20.3 2.67 100 12.5 22.9

-1 0.39 110 375 25.7 11.81 130 45.0 32.0 13.03 160 30.0 42.8

-1 2.77 170 17.5 46.6

-29.11 180 55.5 50.5 5.01 200 77.5 58.2 19.27 250 80.5 75.3 5.16 300 82.0

87. 1

-5.07 CVGraph 6.02 06/23/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-64 WCAP-18660-NP November 2021 Revision 0 U nirradiated Intermediate Shell Forging C (Axial)

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 9:20 AM A= 50.00 B = 50.00 C = 114.51 TO= 47.94 D = 0.00 Correlation Coefficient = 0.987 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Plant: Prairie Island 1 Orientation: Axial 100

~

Temperature at 50% Shear = 48.00 Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluenee: 0.00E+000 n/cm'

~

60 1-----+------4---+---

.<<-+---1/2------+------4---+-----1 QJ

.c

00.

501------1----+-----~ -----+----1------+-----+----1

=

QJ CJ

~

40 1-----+------4---+--

---+----1/2------+------4---+-----I

~

0 L-111111111===::1==--...1....----1._.J.........l..-.l...-...J....----J'---...I....----L-.J.........L._J.._....,___JL.,._....1...._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-65 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: Unirrad Heat: 21918/38566 Fluence: 0.00E+000 n/cm 2 U nirradiated Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature {° F)

Input %Shear Computed %Shear Differential

-60 5.0 13.2

-8. 18

-60 9.0 13.2

-4.18

-60 7 0 13.2

-6. 18

-30 18.0 20.4

-2.40

-30 30.0 20.4 9.60

-30 170 20.4

-3.40

-1 0 31.0 26.7 4.34

-1 0 27 0 26.7 0.34

-1 0 29.0 26.7 2.34 10 43.0 34.0 8.99 10 370 34.0 2.99 10 43.0 34.0 8.99 40 43.0 46.5

-3.54 40 40.0 46.5

-6.54 80 62.0 63.6

-1.64 80 55.0 63.6

-8.64 80 61.0 63.6

-2.64 210 1000 94.4 5.57 210 1000 94.4 5.57 210 100.0 94.4 5.57 300 100.0 98.8 1.21 300 100.0 98.8 1.21 300 100.0 98.8 1.21 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-66 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial 100

~

Capsule V Intermediate Shell Forging C (Axial)

CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 2:49 PM A= 50.00 B = 50.00 C = 95.24 TO= 90. 74 D = 0.00 Correlation Coefficient = 0.990 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear = 0.00 (Fixed)

Temperature at 50% Shear = 90.80 Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/cm'

~

60 1-----+----+------t---+E:l----+----+---1----+----t QJ

.c

00.

50 1------1----+----+-----.J+----+----1------+-----+----1

=

QJ CJ

~

40 -----+----+------ --------------------

~

0 L-....1..-"'-1111111=:~J.........I..-..L........J.-..L...---L-..L...---L-...L..----1-....L...-L...-....L..-l..-...J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/28/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-67 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: V Heat: 21918/38566 Fluence: 6.09E+018 n/cm*

Capsule V Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input %Shear Computed %Shear Differential

-25 5.0 8.1

-3.09 0

10.0 12.9

-2.95 0

10.0 12.9

-2.95 25 20.0 20.l

-0.09 50 30.0 29.8 0.17 50 30.0 29.8 0.17 75 53.0 41.8 11.19 120 60.0 64.9

-4.90 150 70.0 77.6

-7.63 210 100.0 92.4 7.55 300 100.0 98.8 1.22 300 100.0 98.8 1.22 CVGraph 6.02 06/28/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-68 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial 100

~

Capsule P Intermediate Shell Forging C (Axial)

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 7:34 AM A= 50.00 B = 50.00 C = 115.79 TO= 103.21 D = 0.00 Correlation Coefficient = 0.991 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Temperature at 50% Shear= 103.30 Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/cm'

~

60 ----+---+----+----+--

--+----+----+----+-----'I QJ

.c

00.

50 1------1----+----+------+----+----1------+-----+----1

=

QJ CJ

~

40 -----+----+---------------------------

~

0 L-....i.......l-=:::::C:::::....J._.J.........L.-.1...--...J....----J'---...I....----L-.J.........L._J.._....,___JL.,._....1...._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-69 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: P Heat: 21918/38566 Fluence: 1.31E+019 n/cm*

Capsule P Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input %Shear Computed %Shear Differential

-50 3.0 6.6

-3.62

-1 0 130 12.4 0.61 0

18.0 14.4 3.60 50 31.0 28.5 2.49 75 45.0 38.1 6.95 100 38.0 48.6

-1 0.61 150 66.0 69.2

-3.17 200 87.0 84.2 2.82 250 100 0 92.7 7.34 350 100.0 98.6 1.39 400 100.0 99.4 0.59 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-70 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial 100

~

Capsule R Intermediate Shell Forging C (Axial)

CV Graph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8: 10 AM A= 50.00 B = 50.00 C = 100.50 TO = 140.03 D = 0.00 Correlation Coefficient = 0.971 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Temperature at 50% Shear = 140.10 Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/cm'

~

60 ----+---+----+----+--+--+----+----+----+-----'I QJ

.c

00.

50 1------1----+----+------

'---+----1------+-----+----1

=

QJ CJ

~

40 ----~---+----1------1--1-- ---~---+----1----1

~

0 L-....L.-.L-"""""""--====;;.,..,..-..L........1.-..L...---L-..L...---L-...L..----I-....L...-L...-....L..-l..-...J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-71 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: R Heat: 21918/38566 Fluence: 4.02E+019 n/cm*

Capsule R Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input %Shear Computed %Shear Differential 0

3.0 5.8

-2.80 25 6.0 9.2

-3.20 50 16.0 14.3 1.71 50 11.0 14.3

-3.29 75 37.0 21.5 15.49 75 35.0 21.5 13.49 100 19.0 31.1

-1 2.07 150 40.0 54.9

-14.94 200 82.0 76.7 5.26 250 100.0 89.9 10.08 300 100.0 96.0 3.98 400 100.0 99.4 0.56 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-72 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial 100

~

Capsule S Intermediate Shell Forging C (Axial)

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:3 1 AM A = 50.00 B = 50.00 C = 83.40 TO = 134.46 D = 0.00 Correlation Coefficient = 0.991 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Temperature at 50% Shear= 134.50 Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/cm'

~

60 ----+---+----+----+--

--+----+----+----+-----'I QJ

.c

00.

501------1----+----+------ ------1------+-----+----1

=

QJ CJ

~

40 t----:---t---,--+----,--+----+-f-1/4---+---+----+---,---+----,---t

~

0 L-....L..-.1..-....1..----=~..L........J.-..L...---L-..L...---L-...L..----1-....L...-L...-....L..-l..-...J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-73 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: S Heat: 21918/38566 Fluence: 4.39E+019 n/cm*

Capsule S Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input %Shear Computed %Shear Differential

-25 0.0 2.1

-2.14 25 5.0 6.8

-175 50 10.0 117

-1.65 60 20.0 14.4 5.64 72 25.0 18.3 6.73 100 30.0 30.4

-0.44 125 40.0 44.4

-4.35 175 65.0 72.6

-7.56 225 1000 89.8 10.24 250 100.0 94.l 5.89 300 100.0 98.1 1.85 CVGraph 6.02 06/29/2021 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-74 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial 100

~

Capsule N Intermediate Shell Forging C (Axial)

CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/23/2021 6:05 AM A = 50.00 B = 50.00 C = 84.19 TO = 174.24 D = 0.00 Correlation Coefficient = 0.959 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Temperature at 50% Shear= 174.30 Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/cm'

~

60 ----+----+----+----+---- ----------------

QJ

.c

00.

501------1----+----+-------- ----1------+-----+----1

=

QJ CJ

~

40 -----+----+--------- ------------------

~

0 L-....L..-"--.....L..-.L..-....i.==::::i.........1._..1....___,1,_..1....---1,_...1...___,1_....1...._1...-...J..._J..._...J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/23/2021 Page 1/2