ML22067A153

From kanterella
Jump to navigation Jump to search
WCAP-18660-NP, Revision 0, Analysis of Capsule N from the Xcel Energy Prairie Island Unit 1 Reactor Vessel Radiation Surveillance Program, Appendix C, Part 3
ML22067A153
Person / Time
Site: Prairie Island  
(DPR-042)
Issue date: 11/30/2021
From: Benson R, Long M, Mays B
Westinghouse
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22067A147 List:
References
L-PI-22-005 WCAP-18660-NP, Rev 0
Download: ML22067A153 (1)


Text

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-75 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: Axial Material: SA508CL3 Capsule: N Heat: 21918/38566 Fluence: 8.45E+019 n/cm*

Capsule N Intermediate Shell Forging C (Axial)

Charpy V-Notch Data Temperature (0 F)

Input %Shear Computed %Shear Differential 60 5.0 6.2

-1.22 77 20.0 9.0 10.97 90 15.0 11.9 3.09 100 15.0 14.6 0.37 110 30.0 17.9

12. 14 130 30.0 25.9 4.10 160 30.0 41.6

-11.62 170 35.0 47.5

-12.48 180 45.0 53.4

-8.41 200 75.0 64.8

10. 16 250 100.0 85.8 14.19 300 100.0 95.2 4.80 CVGraph 6.02 06/23/2021 Page 2/2
      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-76 WCAP-18660-NP November 2021 Revision 0 U nirradiated Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 9:23 AM A= 42.35 B = 40.15 C = 78.59 TO= -40.02 D = 0.00 Correlation Coefficient = 0.890 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf Energy = 82.50 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs=-65.00° F Temp@35 ft-lbs=-54.50° F Temp@S0 ft-lbs=-24.80° F Plant: Prairie Island 1 Orientation: NA Material: Weld Capsule: Unirrad Heal: 1752 Fluence: O.OOE+OOO n/cm' 0....____.._.....__.....__....____._.....__.....__....____. __...... _....__...... _..._...... _....... _...... _..._......

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-77 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature {° F)

-1 00

-100

-100

-50

-50

-50

-30

-30

-1 0

-1 0

-10 10 10 10 40 40 40 80 80 80 210 210 210 CVGraph 6.02

]\\l[aterial: Weld Capsule: Unirrad U nirradiated Weld Metal Charpy V-Notch Data Input CVN Computed CVN 8.0 16.5 6.0 16.5 25.5 16.5 51.0 37.3 27.0 37.3 32.0 37.3 55.0 47.4 640 47.4 41.0 57.0 62.0 57.0 61.5 57.0 52.0 64.9 75.0 64.9 50.0 64.9 770 73.2 84.0 73.2 61.0 73.2 85.0 78.9 95.0 78.9 62.0 78.9 70.0 82.4 87.0 82.4 78.0 82.4 06/29/2021 Heat: 1752 Fluence: O.OOE+OOO n/cm 2 Differential

-8.54

-10.54 8.96 13.72

-10.28

-5.28 7.56 16.56

-1 5.98 5.02 4.52

-1 2.93 10.07

-14.93 3.77 10.77

-1 2.23

6. 12 1612

-16.88

-1 2.36 4.64

-4.36 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-78 WCAP-18660-NP November 2021 Revision 0 Capsule V Weld Metal CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 2:55 PM A= 46.10 B = 43.90 C = 105.11 TO= 10.57 D = 0.00 Correlation Coefficient = 0.959 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf Energy = 90.00 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs=-29.80° F Temp@35 ft-lbs=-1 6.50° F Temp@50 ft-lbs= 20.00° F Plant: Prairie Island 1 Orientation: NA 120 r;,:i 80

~ -

I

¢::

01) 60 i..

~ =

~

z >

40 u

Material: Weld Capsule: V Heal: 1752 Fluence: 6.09E+018 n/cm' 0....____.._.....__.....__....____._.....__.....__....____. __...... _....__...... _..._...... _....... _...... _..._......

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/28/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-79 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F)

-50 0

32 75 110 150 210 210 CVGraph 6.02 Material: Weld Capsule: V Capsule V Weld Metal Charpy V-Notch Data lnputCVN Computed CVN 25.5 23.3 38.0 41.7 60.0 54.9 640 70.l 78.5 78.5 88.0 84.2 102.5

88. l 79.5 88.1 06/28/2021 Heat: 1752 Fluence: 6.09E+018 n/cm*

Differential 2.23

-3.70 5.07

-6.08 0.00 3.78 14.43

-8.57 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-80 WCAP-18660-NP November 2021 Revision 0 Capsule P Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 7:42 AM A = 42. 70 B = 40.50 C = 127.65 TO = 21.95 D = 0.00 Correlation Coefficient = 0.979 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf Energy = 83.20 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs=-19.40° F Temp@35 ft-lbs= -2.60° F Tcmp@50 ft-lbs= 45.30° F Plant: Prairie Island 1 Orientation: NA Material: Weld Capsule: P Heat: 1752 Fluence: 1.31E+019 n/cm' 0....____.._.....__.....__....____._.....__.....__....____. __...... _....__...... _..._...... _....... _...... _..._......

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-81 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F)

-50

-25 0

50 75 150 250 300 CVGraph 6.02 Material: Weld Capsule: P Capsule P Weld Metal Charpy V-Notch Data lnputCVN Computed CVN 20.5 220 32.5 28.4 35.5 35.8 51.5 51.5 55.5 58.6 71.0 73.6 95.0 81.0 83.5 82.2 06/29/2021 Heat: 1752 Fluence: 1.31E+019 n/cm*

Differential

-1.52 4.06

-0.31 0.04

-3. 13

-2.60 14.01 1.33 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-82 WCAP-18660-NP November 2021 Revision 0 Capsule R Weld Metal CV Graph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8: 13 AM A = 38.60 B = 36.40 C = 136.62 TO = 90.84 D = 0.00 Correlation Coefficient = 0.948 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf Energy = 75.00 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs= 58.00° F Temp@35 ft-lbs= 77.30° F Temp@50 ft-lbs=! 35.20° F Plant: Prairie Island 1 Orientation: NA 60

~

,.Q - 50 I

¢:: -

0Jl 40 1-,

~ =

~

z 30 u

20 Material: Weld Capsule: R Heal: 1752 Fluence: 4.02E+019 n/cm' 0....____._.....__....__.....__...____._....__...__...._ ____.....,_.....__.....__....____._...... _...._ __

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-83 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F) 0 25 50 50 75 150 200 300 CVGraph 6.02 Material: Weld Capsule: R Capsule R Weld Metal Charpy V-Notch Data lnputCVN Computed CVN 17.0 17.4 24.0 22.3 23.0 28.0 24.0 28.0 470 34.4 43.0 53.4 68.0 62.8 75.0 717 06/29/2021 Heat: 1752 Fluence: 4.02E+019 n/cm*

Differential

-0.43 170

-5.03

-4.03 12.60

-1 0.45 5.25 3.25 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-84 WCAP-18660-NP November 2021 Revision 0 Capsule S Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/202 1 12:05 PM A= 43.35 B = 41.15 C = 96.10 TO= 128.30 D = 0.00 Correlation Coefficient = 0.984 Equation is A + B * [Tanl1((T-T0)/(C+Dn)l Upper Shelf Energy = 84.50 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs= 96.00° F Temp@35 ft-lbs=l08.60° F Temp@50 ft-lbs=144.00° F Plant: Prairie Island 1 Orientation: NA Material: Weld Capsule: S Heat: 1752 Fluence: 4.39E+019 n/cm' 0....____.._.....__.....__....____._.....__.....__....____. __...... _....__...... _..._...... _....... _...... _..._......

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-85 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F)

-25 25 72 100 150 175 225 300 CVGraph 6.02 Material: Weld Capsule: S Capsule S Weld Metal Charpy V-Notch Data lnputCVN Computed CVN 8.0 5.5 no 10.8 24.0 21.7 28.0 31.6 45.0 52.5 67.0 61.9 n o 74.8 920 82.3 06/29/2021 Heat: 1752 Fluence: 4.39E+019 n/cm*

Differential 2.55 6.21 2.33

-3.57

-7.49 5.09 2.20 9.75 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-86 WCAP-18660-NP November 2021 Revision 0 Capsule N Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/23/2021 6:13 AM A= 40.60 B = 38.40 C = 74.14 TO= 174.98 D = 0.00 Correlation Coefficient = 0.962 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf Energy = 79.00 (Fixed)

Lower Shelf Energy = 2.20 (Fixed)

Temp@30 ft-lbs=l 54.00° F Temp@35 ft-lbs=l64.10° F Temp@50 ft-lbs=l 93.60° F Plant: Prairie Island 1 Orientation: NA 60

~

,.Q - 50 I

¢:: -

0Jl 40 1-,

~ =

~

z 30 u

20 Material: Weld Capsule: N Heal: 1752 Fluence: 8.45E+019 n/cm' 0....____._.....__....__.....__...____._....__...__...._ ____.....,_.....__.....__....____._...... _...._ __

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/23/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-87 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F) 110 125 150 175 190 200 250 300 CVGraph 6.02 Material: Weld Capsule: N Capsule N Weld Charpy V-Notch Data lnputCVN Computed CVN 17.8 13.5 27.0 18.0 24.5 28.1 29.5 40.6 46.5 48.3 58.5 53.1 n o 70.0 79.0 76.5 06/23/2021 Heat: 1752 Fluence: 8.45E+019 n/cm*

Differential 4.26 8.97

-3.63

-11.11

-1.77 5.41 6.97 2.55 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-88 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA U nirradiated Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 9:35 AM A = 38.62 B = 37.62 C = 72. 72 TO = -43.93 D = 0.00 Correlation Coefficient = 0.910 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf L.E. = 76.24 Lower Shelf L.E. = 1.00 (Fixed)

Temp@35 mils=-50.90° F Material: Weld Capsule: Unirrad Heal: 1752 Fluence: O.OOE+OOO n/cm' 0 1:::::::=:::r::.----1._L_....1....---L----11....--.l..,_.....1...---1_.1....-...L.....1..._.l_.i...,_...L----1..__J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-89 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature {° F)

-1 00

-100

-100

-50

-50

-50

-30

-30

-1 0

-1 0

-10 10 10 10 40 40 40 80 80 80 210 210 210 CVGraph 6.02

]\\l[aterial: Weld Capsule: Unirrad U nirradiated Weld Metal Charpy V-Notch Data Input L. E.

Computed L. E.

7 0 14.3 60 14.3 23.0 14.3 48.0 35.5 26.0 35.5 30.0 35.5 53.0 45.7 60.0 45.7 410 55.0 560 55.0 570 55.0 50.0 62.3 720 62.3 52.0 62.3 710 69.4 78.0 69.4 55.0 69.4 82.0

73. 8 920
73. 8 65.0 73.8 69.0 76.2 78.0 76.2 75.0 76.2 06/29/2021 Heat: 1752 Fluence: O.OOE+OOO n/cm 2 Differential

-7.26

-8.26 8.74 12.51

-9.49

-5.49 7.26 14.26

-1 2.00 1.00 2.00

-1 2.32 9.68

-10.32 1.57 8.57

-14.43

8. 17 18.17

-8.83

-7.17 1.83

-1.17 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-90 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Capsule V Weld Metal CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 3 :03 PM A= 40.36 B = 39.36 C = 124.46 TO= 39.33 D = 0.00 Correlation Coefficient = 0.975 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf L.E. = 79.72 Lower Shelf L.E. = 1.00 (Fixed)

Temp@35 mils= 22.30° F Material: Weld Capsule: V Heal: 1752 Fluence: 6.09E+018 n/cm' 0....____._.....__....__.....__...____._....__...__...._ ____.....,_.....__.....__....____._...... _...._ __

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/28/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-91 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F)

-50 0

32 75 110 150 210 210 CVGraph 6.02 Material: Weld Capsule: V Capsule V Weld Metal Charpy V-Notch Data Input L. E.

Computed L. E.

13.5

16. l 29.0 28.3 43.0 38.0 47.0 51.3 58.5 60.6 720 68.3 82.0 75.0 67 0 75.0 06/28/2021 Heat: 1752 Fluence: 6.09E+018 n/cm*

Differential

-2.63 0.68 4.96

-4.34

-2.08 3.66 7.05

-7.95 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-92 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Capsule P Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 7:44 AM A= 40.90 B = 39.90 C = 141.38 TO= 46.42 D = 0.00 Correlation Coefficient = 0.995 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf L.E. = 80.80 Lower Shelf L.E. = 1.00 (Fixed)

Temp@35 mils= 25.40° F Material: Weld Capsule: P Heat: 1752 Fluence: 1.31E+019 n/cm' 0....____._.....__....__.....__...____._....__...__...._ ____.....,_.....__.....__....____._...... _...._ __

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-93 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F)

-50

-25 0

50 75 150 250 300 CVGraph 6.02 Material: Weld Capsule: P Capsule P Weld Metal Charpy V-Notch Data Input L. E.

Computed L. E.

17.3 17.2 24.4 22.3 28.0 28.3 37.0 41.9 52.0 48.9 66.5 65.8 77.2 76.6 77.6 78.6 06/29/2021 Heat: 1752 Fluence: 1.31E+019 n/cm*

Differential 0.05

2. 10

-0.25

-4.91

3. 14 0.68 0.65

-1.05 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-94 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Capsule R Weld Metal CV Graph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8: 15 AM A= 41.24 B = 40.24 C = 200.59 TO= 148.22 D = 0.00 Correlation Coefficient = 0.956 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf L.E. = 81.48 Lower Shelf L.E. = 1.00 (Fixed)

Temp'.@35 mils=! 16.90° F Material: Weld Capsule: R Heal: 1752 Fluence: 4.02E+019 n/cm' 0....____._.....__....__.....__...____._....__...__...._ ____.....,_.....__.....__....____._...... _...._ __

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-95 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F) 0 25 50 50 75 150 200 300 CVGraph 6.02 Material: Weld Capsule: R Capsule R Weld Metal Charpy V-Notch Data Input L. E.

Computed L. E.

13.5 15.9 20.0 19.2 18.0 23.0 19.0 23.0 40.0 27.2 40.0 41.6 49.0 51.4 68.0 67.0 06/29/2021 Heat: 1752 Fluence: 4.02E+019 n/cm*

Differential

-2.45 0.78

-4.97

-3.97 12.83

-1.60

-2.40 1.05 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-96 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA 60

~ -*-8

._, 50

=

0 *-

~ =

~

Q. 40

~

~ -

~

30 aJ..

~

~ 20 Capsule S Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:39 AM A= 38.35 B = 37.35 C = 105.48 TO= 142.13 D = 0.00 Correlation Coefficient = 0.995 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf L.E. = 75.69 Lower Shelf L.E. = 1.00 (Fixed)

Temp'.@35 mils=132.70° F Material: Weld Capsule: S Heat: 1752 Fluence: 4.39E+019 n/cm' o l::::::::::+/-::::+/-::::i:::::=!~_:_L_..i_...L---'----1.____i_L_..1...--..L....i....---1.----L._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-97 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F)

-25 25 72 100 150 175 225 300 CVGraph 6.02 Material: Weld Capsule: S Capsule S Weld Metal Charpy V-Notch Data Input L. E.

Computed L. E.

3.0 4.0 12.0 8.3 16.0 16.6 24.0 24.2 37.0 41.1 53.0 49.6 64.0 62.8 710 72.1 06/29/2021 Heat: 1752 Fluence: 4.39E+019 n/cm*

Differential

-101 3.69

-0.63

-0. 18

-4.13 3.38 1.16

-113 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-98 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA 60

~ -*-8

._, 50

=

0 *-

~ =

~

Q. 40

~

~ -

~

30 aJ..

~

~ 20 Capsule N Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/23/2021 6: 16 AM A= 38.14 B = 37.14 C = 88.66 TO= 183.63 D = 0.00 Correlation Coefficient = 0.956 Equation is A + B * [Tanh((T-T0)/(C+DT))J Upper Shelf L.E. = 75.28 Lower Shelf L.E. = 1.00 (Fixed)

Temp'.@35 mils=176.20° F Material: Weld Capsule: N Heal: 1752 Fluence: 8.45E+019 n/cm' o l::::::::::i:::::::::l==:::::::l=::C:::::L...---L..---1-.1....-.L....i...---1----J1....-L....i.........L----1._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature (° F)

CV Graph 6.02 06/23/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-99 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F) 110 125 150 175 190 200 250 300 CVGraph 6.02 Material: Weld Capsule: N Capsule N Weld Charpy V-Notch Data Input L. E.

Computed L. E.

15.5 12.9 24.0 16.6 21.0 24.7 24.0 34.5 41.5 40.8 49.0 44.9 68.0 61.7 66.0 70.3 06/23/2021 Heat: 1752 Fluence: 8.45E+019 n/cm*

Differential 2.64 7.37

-3.69

-1 0.54 0.69 4.08 6.30

-4.26 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-100 WCAP-18660-NP November 2021 Revision 0 U nirradiated Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 9:27 AM A= 50.00 B = 50.00 C = 94.85 TO= -22.14 D = 0.00 Correlation Coefficient = 0.959 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Plant: Prairie Island 1 Orientation: NA 100

~

Temperatnre at 50% Shear= -22.1 0 Material: Weld Capsule: Unirrad Heal: 1752 Fluence: O.OOE+OOO n/cm'

~

60 1------+-------1-----'.,..__ ____

--+-___

1/2---______


j. ___ +-__

QJ

.c

00.

501------1----------------+----1------+-----+-----1

=

QJ CJ

~

40 1------+-------l----l_.,, _ __ --+----1/2-------+-------l----+------I

~

0 i.--=:=:;;_J..........L.-.L.........I..-..L........J.-..L...---L-..L...---L-...L..----1-....L...-L...-....L..-l..-...J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-101 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature {° F)

-100

-100

-100

-50

-50

-50

-30

-30

-1 0

-1 0

-10 10 10 10 40 40 40 80 80 80 210 210 210 CVGraph 6.02

]\\l[aterial: Weld Capsule: Unirrad U nirradiated Weld Metal Charpy V-Notch Data Input %Shear Computed %Shear 9.0 16.2 5.0 16.2 no 16.2 55.0 35.7 33.0 35.7 29.0 35.7 53.0 45.9 61.0 45.9 41.0 56.4 63.0 56.4 51.0 56.4 570 66.3 73.0 66.3 63.0 66.3 n o 78.8 82.0 78.8 68.0 78.8 93.0 89.6 970 89.6 89.0 89.6 100.0 99.3 100.0 99.3 100.0 99.3 06/29/2021 Heat: 1752 Fluence: O.OOE+OOO n/cm 2 Differential

-7.22

-11.22 0.78 19.28

-2.72

-6.72 7.13 15.13

-1 5.37 6.63

-5.37

-9.32 6.68

-3.32

-1.76 3.24

-1 0.76 3.40 7.40

-0.60 0.74 0.74 0.74 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-102 WCAP-18660-NP November 2021 Revision 0 Capsule V Weld Metal CVGrnph 6.02: Hyperbolic Tangent Curve Printed on 6/28/2021 2:56 PM A = 50.00 B = 50.00 C = 94.06 TO = 49. 73 D = 0.00 Correlation Coefficient = 0.983 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear = 0.00 (Fixed)

Plant: Prairie Island 1 Orientation: NA 100

~

Temperature at 50% Shear = 49.80 Material: Weld Capsule: V Heal: 1752 Fluence: 6.09E+018 n/cm'

~

60 ----+----+----+---+--+----+----+----+----+----'I QJ

.c

00.

50 1------1----+----+--+-;1-+-++----+----1------+-----+----1

=

QJ CJ

~

40 -----+----+-----------------------------

~

0 L.-.....i..--=::::::i;._.1.........1.._..L........J.-..L...---L-..L...---L-...L..----I-....L...-L...-....L..-l..-...J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/28/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-103 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F)

-50 0

32 75 110 150 210 210 CVGraph 6.02 Material: Weld Capsule: V Capsule V Weld Metal Charpy V-Notch Data Input %Shear Computed %Shear 10.0 10.7 25.0 25.8 50.0 40.7 50.0 63.l 80.0 78.3 95.0 89.4 100.0 96.8 1000 96.8 06/28/2021 Heat: 1752 Fluence: 6.09E+018 n/cm*

Differential

-0.71

-0.78 9.31

-1 3.12 1.73 5.60 3.21 3 21 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-104 WCAP-18660-NP November 2021 Revision 0 Capsule P Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 7:43 AM A = 50.00 B = 50.00 C = 127.09 TO = 20.37 D = 0.00 Correlation Coefficient = 0.990 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Plant: Prairie Island 1 Orientation: NA 100

~

Temperature at 50% Shear = 20.40 Material: Weld Capsule: P Heat: 1752 Fluence: 1.31E+019 n/cm'

~

60 ----+----+----+--+---+----+----+----+----+----'I QJ

.c

00.

501------1----+----- ------+----1------+-----+----1

=

QJ CJ

~

40 -----+----+---- -----------------------

~

0 l:::::::::C::.......J_...1.......J._.J.........l..-.l...-...J....----J'---...I....----L-.J.........L._J.._....,___JL.,._....1...._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-105 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F)

-50

-25 0

50 75 150 250 300 CVGraph 6.02 Material: Weld Capsule: P Capsule P Weld Metal Charpy V-Notch Data Input %Shear Computed %Shear 27.0 24.8 35.0 32.9 43.0 42.1 53.0 61.5 710 70.3 95.0 88.5 100.0 97.4 1000 98.8 06/29/2021 Heat: 1752 Fluence: 1.31E+019 n/cm*

Differential 2.16 2.13 0.95

-8.45 0.74 6.51 2.62 121 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-106 WCAP-18660-NP November 2021 Revision 0 Capsule R Weld Metal CV Graph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8: 14 AM A= 50.00 B = 50.00 C = 122.79 TO= 113.26 D = 0.00 Correlation Coefficient = 0.989 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Plant: Prairie Island 1 Orientation: NA 100

~

Temperature at 50% Shear= 11 3.30 Material: Weld Capsule: R Heal: 1752 Fluence: 4.02E+019 n/cm'

~

60 ----+---+----+----+-----+----+----+----+-----'I QJ

.c

00.

50 1------1-----+----+-----+-l'----+----1------+-----+-----1

=

QJ CJ

~

40 t----:---t---,--+----,--+--Hl-+----+---+----+---,---+----,---t

~

0 L---111111111111=:C:::----1.-.L.........l..-.1...-...J....----J'---...I....----L-.J.........L._J.._....,___JL.,._....1...._J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-107 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F) 0 25 50 50 75 150 200 300 CVGraph 6.02 Material: Weld Capsule: R Capsule R Weld Metal Charpy V-Notch Data Input %Shear Computed %Shear 17.0 13.6 22.0 19.2 20.0 26.3 22.0 26.3 40.0 34.9 67.0 64.5 76.0 80.4 1000 95.4 06/29/2021 Heat: 1752 Fluence: 4.02E+019 n/cm*

Differential 3.35 2.81

-6.30

-4.30 5.09 2.47

-4.42 4.56 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-108 WCAP-18660-NP November 2021 Revision 0 Capsule S Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/29/2021 8:38 AM A= 50.00 B = 50.00 C = 75.74 TO= 89.03 D = 0.00 Correlation Coefficient = 0.996 Equation is A + B * [Tanh((T-T0)/(C+Dn)l Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Plant: Prairie Island 1 Orientation: NA 100

~

Temperature at 50% Shear = 89.10 Material: Weld Capsule: S Heat: 1752 Fluence: 4.39E+019 n/cm'

~

60 1-----+-------l----+---------1/2------+-------1----+-----1 QJ

.c

00.

50 1------1----+----+---- ----+----1------+-----+----1

=

QJ CJ

~

40 t----:---t---,--+---,--+---iED-+----+---+----+--,---+----,---t

~

0 L-....L..-.I.-.....L.-.i:::::::;;..,.,.._..L........J.--'----L-..L...---L-...L..----1-....L...-L...-....L..-l..-...J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/29/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-109 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F)

-25 25 72 100 150 175 225 300 CVGraph 6.02 Material: Weld Capsule: S Capsule S Weld Metal Charpy V-Notch Data Input %Shear Computed %Shear 10.0 4.7 10.0 15.6 40.0 38.9 60.0 57.2 80.0 83.3 90.0 90.6 100.0 97.3 1000 99.6 06/29/2021 Heat: 1752 Fluence: 4.39E+019 n/cm*

Differential 5.31

-5.57 1 06 2.81

-3.34

-0.64 2.69 0.38 Page 2/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-110 WCAP-18660-NP November 2021 Revision 0 Capsule N Weld Metal CVGraph 6.02: Hyperbolic Tangent Curve Printed on 6/23/2021 6:15 AM A = 50.00 B = 50.00 C = 98.52 TO = 193.45 D = 0.00 Correlation Coefficient = 0.938 Equation is A + B * [Tanh((T-TO)/(C+DT))J Upper Shelf%Shear = 100.00 (Fixed)

Lower Shelf %Shear= 0.00 (Fixed)

Plant: Prairie Island 1 Orientation: NA 100

~

Temperature at 50% Shear= 193.50 Material: Weld Capsule: N Heal: 1752 Fluence: 8.45E+019 n/cm'

~

60 ----+----+----+----+----------------------

QJ

.c

00.

50 l----'---+---'--t-----'--+---+---9----+----+---+--;__--I

=

QJ CJ

~

40 -----+----+------------- ----------------

~

0 L-....L..-.L-....L..-""---=t:~..L........J.-..L...---L-..L...---L-...L..----1-....L...-L...-....L..-l..-...J

-300

-200

-100 0

100 200 300 400 500 600 Temperature{° F)

CV Graph 6.02 06/23/2021 Page 1/2

      • This record was final approved on 12/1/2021 8:24:23 AM. (This statement was added by the PRIME system upon its validation)

Westinghouse Non-Proprietary Class 3 C-111 WCAP-18660-NP November 2021 Revision 0 Plant: Prairie Island 1 Orientation: NA Temperature (0 F) 110 125 150 175 190 200 250 300 CVGraph 6.02 Material: Weld Capsule: N Capsule N Weld Charpy V-Notch Data Input %Shear Computed %Shear 30.0 15.5 25.0 19.9 30.0 29.3 30.0 40.7 50.0 48.2 40.0 53.3 85.0 75.9 1000 89.7 06/23/2021 Heat: 1752 Fluence: 8.45E+019 n/cm*

Differential 14.48 5.05 0.73

-1 0.74 175

-13.32 9.09 10.31 Page 2/2