MONTHYEARPMNS20210713, Meeting with X-energy LLC: TRISO-X Pebble Fuel Qualification Methodology2021-05-25025 May 2021 Meeting with X-energy LLC: TRISO-X Pebble Fuel Qualification Methodology Project stage: Request ML21246A2892021-09-0202 September 2021 X-Energy, LLC, Submittal of Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology, Revision 2 Project stage: Request ML21266A4292021-09-28028 September 2021 Email to X Energy, LLC - Withholding Determination - Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology Project stage: Other ML21266A4302021-09-28028 September 2021 NRC 897, Withholding Determination - X Energy, LLC - Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology Project stage: Other ML21267A1212021-10-13013 October 2021 NRC 898, Completeness Determination, X Energy, LLC - Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology Project stage: Other ML21267A1222021-10-13013 October 2021 Email to X Energy, LLC - Completeness Determination - Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology Project stage: Other ML21334A2302021-12-0202 December 2021 Email to X Energy, LLC - Transmittal of Requests for Additional Information - Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology Project stage: RAI PMNS20220087, Meeting with X Energy, LLC Regarding Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology2022-02-0101 February 2022 Meeting with X Energy, LLC Regarding Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology Project stage: Request ML21354A2892022-02-11011 February 2022 Summary of the June 4, 2021, Closed Meeting with X-Energy, LLC TRISO-X Pebble Fuel Qualification Methodology Project stage: Meeting ML22059A7702022-03-28028 March 2022 X Energy, LLC (X-energy), Submission of Responses to Requests for Additional Information for Topical Report, TRISO-X Pebble Fuel Qualification Methodology Project stage: Response to RAI PMNS20220423, Closed Meeting with X Energy, LLC Regarding RAI Responses for Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology2022-04-18018 April 2022 Closed Meeting with X Energy, LLC Regarding RAI Responses for Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology Project stage: Request ML22108A1362022-04-18018 April 2022 Email to X-Energy, LLC - Withholding Determination - RAI Responses for Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology Project stage: RAI ML22108A1072022-04-18018 April 2022 NRC 897 Withholding Determination Form for Submission of X Energy, LLC Responses to Requests for Additional Information for Topical Report, TRISO-X Pebble Fuel Qualification Methodology Project stage: RAI ML22166A4242022-07-15015 July 2022 Summary of the May 20, 2022, Closed Meeting with X Energy, LLC Regarding XE-100 Topical Report TRISO-X Pebble Fuel Qualification Methodology Project stage: Meeting ML22166A4182022-07-15015 July 2022 Summary of the February 10, 2022, Closed Meeting with X Energy, LLC Regarding XE-100 Topical Report TRISO-X Pebble Fuel Qualification Methodology Project stage: Meeting ML22216A1792022-07-29029 July 2022 Submission of X Energy, LLC (X-energy) TRISO-X Pebble Fuel Qualification Methodology Project stage: Request ML22265A2182022-09-21021 September 2022 Withdrawal of X Energy, LLC (X-energy) Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology, Revisions 1 and 2 Project stage: Request ML22363A0162022-09-29029 September 2022 X Energy, LLC - Change in Review Schedule for Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology, Revision 3 Project stage: Other ML22255A2352022-09-29029 September 2022 NRC Form 897, Withholding Determination, X Energy, LLC - Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology, Revision 3 Project stage: Other ML22255A2372022-09-29029 September 2022 Email to X Energy, LLC - Withholding Determination - Xe-100 Topical Report TRISO-X Pebble Fuel Qualification Methodology, Revision 3 Project stage: Other ML22194A9482022-11-0707 November 2022 Transmittal Email - X Energy, LLC - Draft Safety Evaluation of Xe-100 Topical Report TRISO-X Pebble Fuel Qualification Methodology, Revision No. 3 Project stage: Draft Approval ML22363A2852022-11-30030 November 2022 X Energy, LLC (X-energy), Proprietary Review of Draft Safety Evaluation for Xe-100 Topical Report TRISO-X Pebble Fuel Qualification Methodology Project stage: Request ML22362A0642023-02-0202 February 2023 X-Energy, LLC – Acknowledgement of Withdrawal of Revisions 1 and 2 of XE-100 Topical Report: TISO-X Pebble Fuel Qualification Methodology Project stage: Withdrawal ML23034A2232023-02-0303 February 2023 Form 897 Proprietary Determination for Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology, Revision 1 Project stage: Other ML23034A2262023-02-0303 February 2023 Email to X-energy - Withholding Determination for Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology, Revision 1 Project stage: Other ML22327A2012023-03-0909 March 2023 X Energy LLC - Safety Evaluation of XE-100 Topical Report TRISO-X Pebble Fuel Qualification Methodology Revision No. 3 (EPID No. L-2021-TOP-0011) - Redacted Project stage: Approval ML22327A1982023-03-0909 March 2023 Cover Letter – X Energy, LLC - Safety Evaluation of Xe-100 Topical Report, TRISO-X Pebble Fuel Qualification Methodology, Revision No. 3 Project stage: Approval ML23079A1082023-03-20020 March 2023 NRR E-mail Capture - X Energy, LLC - Safety Evaluation of Xe-100 Topical Report, TRISO-X Pebble Fuel Qualification Methodology, Revision No. 3 Project stage: Approval ML23184A0052023-07-0303 July 2023 Email to Travis Chapman of X-Energy Regarding Proprietary Review for Topical Report, TRISO-X Pebble Fuel Qualification Methodology, Accepted Version Project stage: Other ML23184A0062023-07-0303 July 2023 NRC 897 for TRISO-X -A Version Project stage: Other ML23184A0182024-02-0606 February 2024 X Energy LLC - NRC Form 896 -A Topical Report Verification for TRISO-X Pebble Fuel Qualification Methodology Topical Report Project stage: Other ML23184A0172024-02-0707 February 2024 X Energy, LLC - Email Correspondence Regarding -A Topical Report Verification for TRISO-X Fuel Qualification Methodology Topical Report Project stage: Other 2022-04-18
[Table View] |
Text
From:
Wagner, Katie To:
TChapman@x-energy.com Cc:
inordby@x-energy.com; Vechioli Feliciano, Lucieann
Subject:
Transmittal of Requests for Additional Information - Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology Date:
Thursday, December 02, 2021 10:38:00 AM Good morning:
By letter dated September 2, 2021 (Agencywide Document Access and Management System Accession No. ML21246A289), X Energy, LLC (X Energy), submitted for U.S.
Nuclear Regulatory Commission (NRC) staff review XE00-R-R1ZZ-RDZZ-L-000633, Revision 2 of Xe-100 Topical Report: TRISO-X Pebble Fuel Qualification Methodology.
By the communication dated October 8, 2021 (ADAMS Accession No. ML21267A122) and the attached form (ADAMS Accession No. ML21267A121), the NRC informed X Energy of the results of its completeness review.
The NRC staff reviewed the report and based on the review, the staff concluded that additional information is needed to complete the review. I have placed an electronic version of Requests for Additional Information (RAIs) for the report in the box.com folder and have given you access to it. This email serves as formal transmittal of those RAIs.
NRC staff have not redacted any proprietary or sensitive unclassified information (SUNSI) from the RAIs so the file in the ADAMS and box.com are marked as containing export-controlled and proprietary information. The RAIs have also been placed in ADAMS as nonpublic so they can be declared an Official Agency Record. When responding to the RAIs, please provide a version containing SUNSI and a non-sensitive version of both the RAIs and the RAI responses. Your formal response, provided via letter under authorized signature, will generate the public version of the RAIs as well as the responses.
During a clarification call held on December 1, 2021, with X-energy staff that included Travis Chapman and Pete Pappano, it was agreed that a response would be submitted by January 31, 2022. This date will support the NRC staffs established review schedule.
If you would like to discuss the schedule further or need additional time to provide the responses to the RAIs, please do not hesitate to contact me.
This email will be placed in ADAMS and will be declared public.
- Regards, Katherine Wagner Project Manager NRR/DANU/UARL U.S. Nuclear Regulatory Commission (301) 415.6202