0 E

D C

B

~ A 0

N 0

C Cf>

0 U

O

  • C L{)CJ>::,

-u o::

  • Z

-en:,:

,:;;i-_,_

'<c<) L II -

0 0::: o::::f l/

w sr ::,

V>ZO

<t O <t o::ou 4NPG

~ s ;zs I SI£ I 1717 I

2 I

3 I

I 5

I 6

I 4160 V SKGR BUS SECT. F A------------

B----+-------

II 2

ii27DCHF l 5

'ls2HF1S s rn CONTACTS POSITIONS A

INT B INT: C l -t~f---2 I

X X

X X

c------------

2 r~ R I 62HF I 5 2

X X

52HFIS 75/511 f,Oo/511 SO/SA MHF/5 I

I J-{-<r l l LI J

~

n h

LI u

u 11.,

n

}

70 8US SECTION F BUS DIFFE'.ReNT/1\\L SEE DWG. 441343 L-it--+---<>-'-<>--

SONHF/5 r------,

I,

lil I "A_-_4;~~~--<>-r<>-----..._

I

'I--+-+--<>---<: >------~I-<>

~T I I 7

~

I L---- __ _J

.A 8

C w THREE LINE DIAGRAM D. C CONT. BUS UNDEPMX.T/IGE I

MANUAL CLOSE I

I AM

.;,!:ff§_

Q§_

- oc-c--------~

.,j,.

'""" f- "" -1'

( I OH _J;'

SHH l 5 CNSI DETA I L A FOR S I PP 2-2 ONL Y AUTO CLOSE I

INDICATION I

SAFETY INJ ECTION S IGNAL I

I

~

REF. DI\\G 441340 e=

MANUAL TR IP M l TDD T l 27DCI MI HF 15

~--------------------1 I

CNS I 1

SHF I 5 ~

BF ----:'.?,

i C>p i:

I 1 0 F ------0 3 -li-,3C 3

X X

7-1 ~ 7C 7

X X

X lf-tr-llC II AMMETER SWITCH X

X AM SW USED AT LOCATION SI-/FIS, SHHIS SHF l 5 CNS I

'- -------=-=-=-=------~

--'~ FOR SI PP 2-2 POTENT IAL I NT ER LOC~

I AUTO TRIP I

14KV BUS UV, OYERWRRE~

I I

SEE DET AI L " A" BELO\\/ LEFT

.5.IS TIME..PEt..AY REI..A Y OVERCURRENT I

AUXILIARY RELAY ltNDICATIONl I

I t--(]U=T-]0~2---4...--,,._. _ _.!S~*H~~i=-ISPT~Q!.~S~I------------------------------+----<<.~---,.----t---------------l-----------------

L..!.Jt-c '=:c------------------------------------+----~-',ti..:..._-+----+-----,

b.

UT*OI

'::I.B..:..Q.1 L..{0}-<;>--PC-o-----<~*-------- --------------~

I~

Q!fil c

(0--

B __ 52HF/5 I

ICS/ STAAT SZHFIS IC. CS/CLOSE S2HFl.5 CI CS//IEU T.

.START G

t ',

R A S2HFIS Tc.sJSTCIP 2

~---

J,,

2C 52HF/5 cslTRIP

, SHFl3 34T27XHF T

/i. Rco p 'h 51HFl5 Sl/f/5 I

3A BO 3J.. co A?CNSI D1 CNSl

£2 4sHFIS Tl 12HFIS i,n1 TDC CJJSI 8 'fCNSI

\\Tco roe I INST 6

2y 6y 2y 6y z y I

.JG 2

SHFIS

, SHFIS it

~

S/IF/ff 2*/

g,,CNSI E,,,--52H' 15

~~ CS/ NEU T. START

~

J

)SN!=/5

~

'1v RES.

ir 40().Q.

S

/DOW SEf A, !AU.,,_

UC -01 0

~rl.L_

.Jt--

---...~-+----------------------+---1 B 125 V DC CONTROL SCHEMATIC 62HFl5 TD

~ Tl R I T2 R2 T3 R3 -4 R4 SAFETY INJECTION PUM,0 N9 21, CIRCUIT N9 F/5HOO

., tt:~UiLJiLJ iB4 -**-***- MI -*-*** M2 -*****-M3 -*-*--* M4 _.

TYPICAL SC/IEMATIC p1AGRAM FOR SAFETY INJECTION FUMP N~* i?.I & 22 EXCEPT AS ~OWN IN TABLE BELOW MOTOR MOTOR cxr BKR. C/RCVIT BUS DC BUS UNDERVOLTAGE A LA RM CIRCUIT NQ 's Nfl LOC. N9 N9 NQ SECTION CKT N<l RELAY LOC/'iTTON CONTACT O>fiRCURf?Bfl GROUND CONT. BUS TRIP DVERCURRE.N, DC UV 2/

MHF/5 SWFJS FISHOO F

1/3D 27J<.HFT SH!=l3

~C>-11---0J AIO!JOODF AIO!J02DF AV4407DF 22 MHH/5 52HHl5 HISHOO H

314D 27)(.HHT SHHl3

% 0-H-oJ, AIO!JOODH AI0903DH.Al/4207DH I

I I

I I

7 S/'11 _ __

Jlflf - -

B B

.1'fcNSI D

SHFIS I

7 I

I 9

I 10 TABLE OF DEVICES DEVICE NP FUNCTION RATING : MFR TYPE CAT.(DfVG,}I',

REMARKS POSIT ION S m

Cl:JHTACTS TRIP TRIP CLOS< REMARKS 2HF!6 ZJ.lf{II:>

SAFETY INJECTION SIGNAL TIMING REL ! 120V AC 14(;ASTAT --

kEFEREI-Jt:e.. 14-

',SAf'lifY 11.Jn;crl<N SJ!;NAt-TIM11.JGr !is-,'-*-"+

1,:'a 2"'0--v-;A'=c+-AAA-:=-::cc,,sr,='i'.-:::i--1---+----+,,=,

_, _-=

__ "'_""-"-*c=-e=-,=

,,--l

~Nrr I --t t---JC X

TI-IIS DM; 2-il-ZC X

THIS DKG 3 -

H-JC X

X SPARE 4--lt-4C X

SPARE 5----ll-SC X

X SPARE SC--t 7-il-7t X

X SPARE JC-;

CONTROL SWI TCH ~

QHH/5 cs cs USED AT LOCATION SHF/5 S!if!!§ SPRING RETURN 1tl NEUTRAL CONTACTS

- A

--ii-B

--if-C

--ii-D

- E

--1 1-F POS ITIONS REMARKS STOP NEUT ST'ART X

THIS DIM;.

X THIS D"'5-X X

THIS uv.G X

SPARE X

X THIS DtvG SPARE S2HFJ5 52HHl5 CONTROL SWITCH -c:s-

~

USED AT LOCATION CNSI SPRING RETURN TO NEUTRAL ZTOCHFIS,HH~ DC COJITRO(. OOS UNDERVOLT4E REL IZSY DC G.E. Cl,.

HGA 27/IJIFT, HHT 4 XV UNDER'-,0<.. TAGE TRIP AW<. REL.

17DCIHfl5. HHl5 DC CONTROL BUS UNDERI/OLTAGE RELAY 125'1 DC AGASTA T EGPO 62HF15,HHl5 BKR CLOS ING SPR ING TIME DELAY REL AY 125 1' DC AGASTAT ET ~

',sONHFIS,HH/!, GROUND DVERCURRENT SENSOR SIHFIS,H/115 OVERCURRENT RELAY SIXJIFIS, HHIS OVERCURRENT.AIJJ!./LIARY REI..AY 24V DC G.£ Co.

H~A S2HFl5, HH/5 CIRCUIT BRE AKER

~.~

CI RCUI T BREAKER AU X Sf/ITCH

~

.52~~15 CI RCUI T BREAKER CEL L INTLK (6), (7)

(3), (IZ)

(3), ( 12)

(3), ( 12)

TRI PS ON UNDERVO L TAGE

e. TRANSFER TO DIESEL ALARM ONLY REC NO. 6 00 9 838 MRT OF SM.R.

PART OF SMilR.

CONTROL TRANSFER RELAYS

!MONITOR L IGHT!

0 270( 1 HF 15 I CONTACT I SHFIS 13TH/IO 19

>-- L/ --O S2HFIS

~
21)

>-L2--<>

SHFIS BTHIID r ILJI R I TW'""~I t 'U4 R4 3

"'"'U"'

_J a..

a..

j_g

..,en en

B4. -..... M 1._.... MZ....... M3 ***-***M4._

£QUIPM£NT LOCATION NUMBERS TE.RMINAL l30X AREA H N r2 110 BTH / tO CNS!

MHF/5 SHFIS CONTROL BOARD SAFETY INJECTION SAFE.TY INJECTION PUMP Nfl 21 SWITCHGEAR 4 KV BUS F CUBICLE /5 DATE I I 2009 REFERENCES t DESCRIPTION OF ELE.C. SCHeMAT/C DIAG.'s,SrMBOLS ~ CXT DESl6NATIONS _________ 050003

2. EQUIPMEJ.IT LOCATION NUMBERS _ _____ _ _ _ __ _ ___ _ ____ _ _ _ _____ __ __ _ ___ _ 10 3013
3. SING.LE LINE METeR & RELAY DIAG 4160 V SYSTEM SH.2 ( BUSF, _________ *"'4/2 29
4. SINGLE LIN£ METER & RELAY DIAG. / 2S V OC SYSTEM ___________________.44/240 S. SCHEMATIC DIAG. 4160V 8US DIFFERENTIAL SH. 2 _______________________ _ 441.343

'- SCHEMATIC DIAG. 4/bOV BUS F

AU70MATIC TRANSFER __________________.441352

7. SCHEMATIC D11'1.G. 4160V BUS H

AUTOMATIC TRIWSFE'.R __________________ 441354 8 SCHEMATIC DIAG. POTENTIAL & SYNCHRONIZING 4160V SYSTE.M _____________ 441340

9. LOGIC DIAGRAM SAFE.TY INJECTION PUMPS __________________________ /0 27':J4 ID. PIPING SCHEMATIC SA FETY INJECTION SYSTEM _______________________ ! D8005,

{I. SCHEMATIC DIAG. MAIN ANNUNCIATOR SH f ____ _ __ _ ______ _ ____ __ __ _ _ _ _.500171 12 SINGLE L/NE ME.TE.R & RELAY DIAG 4lr;;O V SYSTEM SH3 (SUS G 1/,H) _______ _441230

/3. SCHEMATIC DIAGRAM MONITOR LIGHT /3QX C __________________________ _4414f4-'

14.usr OF tLecrRtc.AL :Pl=VJCl:;5 /'OR,.~~c:rtOJ*Ui C0J.dR()L CIR.CI.IIT5 ------------ 05001/

I 5.

P. D.S.

CONTROL CIRC UITS SCHEMATIC DI AGRAM~5009838-69 16. SCHEM ATIC DIAG AUX & FUE L HAND L I NG BLOCS VEN T I L AT ION SYS <PO V I 1 _____ 454671 17,

SCHEMAT IC DIAG AUX & FUEL HANDL I NG BLDGS VENTI L AT ION SYS <POV 21 _____ 454 678 KEY DWG. SECT ION 4 I

NUCLEAR SAFETY RELATED U~l l T 2 ELECT R ICAL SCHE MAT I C DIAGRAM SA FETY I NJEC TION PUMP DI ABLC CANYON PO'NER PLANT PACIFIC GAS AND ELECTRIC COMP ANY SAN FRANCISCO, CAL I FORN I A I

I OWG SCALE:

BlLL OF MATU SUPSDS:

SUPSD BY:

~

,,,l B

C P.G. &E.

SYST EM PHASE SEQUENCE A-C-8 rOLD U7 I-OL D~

OL04 cu,