ML21305A233
Text
N
=>
0 < u E
FOUl D
C FOlD B
A
~
~
~
5
<< er 96llvv SA.
ti-let
-.-----iC]J---- P'2.
te.
TRAIN A CLOSE a-I HI CNT.
RNBTA 807-1 2
5A
,Ntl.
f1i. rPI
--.-,cJ]---o--- Pl ~
!f'IJOL 0
6 FOi?
~
I f
"< i-, l=f
~
_.J u.:L C8 r RNST,11 807-Z RN:,¢A
/-I
,:;z~-5
- -",:;+
1-/--o---J J?NSIJ/l RNSTA D
~I 3
TRAIN B CLOSE 1/ICIJl{TII/N/IENT P,te~~
11/f STE"A#,K§/1,';.
RNST B07-r--rr T (.~
CB t Et. -
~-z !J,;s, 1
)(PJI/S82I POs8ZI wl4--5 DT CLOH 1-2.
- ~1!
RHS¢8
/*l J?NSTIJ XP~54'21 x~vz.,s t
4
!NOl~ATION G,
~r C.[3
.3 (,
X P)IIS316 pos376 OPEN 3P.
A l,\\OIIITOR L IG ~T
.. 4 1
toNTAn j
11.EF 11.EF. 10
? BnlllO TtJEKFDS I -
~ll#I-Jt.3WXPIS8ZI A
P0~821 CLOSE XPPS821 C.[3 ES
)(PjlS377 POS3H CLOSE b 61MIIO 5
"I
- CONTACTI
--it--
A
--it--
B
--Jt--
C
-ll-D 6
POSITION~
REMAP.KS c~OIE /JEUT ~PEN
)(.
SPARE X
X 5PAIU X
THIS DWG X
X r~,s owe;,
CONTROL SWITCH FC.V41 > fCV41, FCV43 fCV44 cs cs ts
' cs USED AT L0CA.TI0l-l
- ,e
- SPRINC. RE1Ul1.t-l TO NE\\JTRl>.L FROM OPEN C0IJTACT!>
POSITIONS P.EMA.RK'i>
'"=
- c'-'>Se OPEN A~i-" A
)(.
61<£Et..l LIGHT G-fj-D B X
.SPARE
"--lt---f C X
SPAR!:
- ~1-" D
.x SPAR.£ 7
to*rr11.crs PoS ITIO'-IS t\\OSE 1~:
RE~ARKS A..-jt---0 A.
X REDL/6HT
/<:~1---D I!,
X
!WARE e-fl-F C X
SPARE
"~1-* D X
SPARE VALVE CLOSE POSITION SWITCH rus 377, PQS 37C,, POS 38i, POS 38.3
~I 8
LOC. Y.P<j;S377, XP¢537~, v,:,p5 381, XPOs 3!13 lco!'JTACTS POS ITIONS CLUSE i~:
REMARKS IA-,!-"
- X N\\ON ITOR Ll6HT iw--,;-t>
5 X
A.LARM- ~F~
OEVltE WO.
K'-lr, IH,13 sv
'l.'lt, 2'18 300 30 1 303,304
- 301, 301,188 187, 18(,
182 fCV __ _
PO~
9 TABLE FUNCTIOIJ HI C0NTl',INMENT PRESS 0C.,
5TEArA llRE"J>,1<. >-u)(. RfLl',VS SOLENOID VI\\LVES fLOW COIJT!l.OL VALVE VALV'f POSITION $WITCH S'\\FEGUARD TEST RELAY SAFEGUARD TEST LIGHT OF
~TING 10 DEVICES MF!l.. ITYPE lt,.TI0WG.NO.I R E/11\\.0.P.KS
/,7) (8) I ESF NM".f/6NAL 12_) _
SEE TM~£ f0R VJ,.LVE NO':.,.
sn: TML, FOR swm" N.*
- 8)
ICONT~CTS OPEN DURIIJG TES (8)
I PUSH ro TEST SV303 t::,
FOi(
SV3{)L/
t, SV307 SV2'8 FCVl-1 SEE. tJOTE. 3< "-fr--"
E s
C X
.SPARE 2. MAIN STEAM ISOLATION VALVES ARE ATO/ FAIL CLOSED; SOLENOID VALVES ARE ENERGIZED
'[O VE>JT > CLOSING ISOLATION V_.,LVES. (ATO= AIR 7'0 OPl=N)
&SV304, KNST6 R!VSTA F1111-==o=
~N't------------- ------=
,Vl--b--- 1--1'2. -----o--- 1--12------ Nt VALVE OPEN POSITION SWITtH : P0537b,P05318 POS 380 1 P05 3B1 0f1:_
C
~
ENOt'II XPj!l5~76 lOC.. )(PjllS)7', )(r,IS:l76, XP,ll~ l 60,' )(PjJS 38'!.
FCV 41 MAIN OTHE:11. MAIN STEAII\\
VALVE6 SEE MOTE 2 STE AM No.1 ISOL. VALVE 511-1\\\\LII.R 11.S SflOWN IIJ T/>.SLE BELOW 5DL.VLV. TRAIN A S0L.VLV-TII.AIN B ltP?'S 317 CIRCUIT N0.10292.SVOI r I02C,8SVOI
- Cl~WIT,S Ll5TED ON DWG. /02770, LOGIC. CIRCUITS ON DIJG, 102.762,,3,64,,5" St"LIC:E STtAM STOP 1/LV. TRAIN A.
STEAM STOP Vll/. TRAIii B VALVE PO~ITION SWITCHES VAL\\I E t>. (.
VALVE C.IRCU IT DESC.R1PTIOIIJ CIRCUIT LOG. J,Jo.
HO, LOC.,
(. LuS c.
i;,n,.,.a N CONTACT OEVIC ~
COl*lT,l,q tJo.
NO.
LO C I.JO, LOC.
MAIN STEIi.iA i ISOL.V, ll'lD/211D
)(.fCV41 l01'l"I.SV0i 2'1'2 XSV2'll t'lS
~SV"l.'lB Et:!DZ"!I FW41 ro2qesvo1 10300SVOI FC.V41 2
11~0/2110 XFC-V42.
103015'10\\
300 X~V300 301
)(5'1301 END2.49 I03C>3 $VOi FCV43 3
ll'l 0/ 3150 XFC-V43 IO 304 SVC)I 303 6 )(SV303 304 6 :i.sv.304 END.329 10~0~ SVOI FCV44 4
l l'lD/ 3150 XFC.V44 30-, 6 )(!,V ?,O'-
301 6 )(SV~07
.END22G
'I0307SVOI
[:, TRANSIENT SURGe..SUPf'ReS50R. f?.£/l"tOVED OPEN MAIN STEAM UNE ISOLATION INDICATION MONITOR LT.
CONTACT R.EF, 10 SA
~Pl~<
I
',I.<< t I
l'J alFcvas AlFcv2s
-I cs/ OPEN r CS/NE/ff-OP!N TO ERFDS f BTHIIO MilX05*24-I,3W C POSIBS CLOSE OEVIC.E.
K {, I c;,
Ki.. I lo Ki..23 K '=>2:,
LDC LDC.
Pos
~oc.
Pos RNSt,A. u4.:.ti--
K(, tb P.NS1 B "t'-=i'i--
377 xrss.V1 371:,
i.1.. ~ib
,u -~
a21 X,,~21 Ei14--,
ru.. 4 -_-:,
379
)(
- .379 318
°114-,o K61b
.i[,o 822
,I'.
822 62.§*CI
"'2.S,-.,
3BI
- ~,
_t*-10 K"23 jt.,o 823 1,1'.fl 82.~
3 !!>O
~=-*
OU.- \\
3B3
,(P$5-.,,.,
'~
K<.23
~:jt-_z jt.z 382 82!7
,tr-..:..,q;, L; CLOSE OPEN CONTACTS POSIT"IONS REMARKS CLOSt NEIJI OPO
-ti-A X
X THIS Dl'v/i.
- H-8 X
THIS DWG
-u---
C X
.Sl'AJ?~ -
-H-D X
X
.Sli'IRl:
FORSVl8f!.&SVIB~)! /,'f,1-ca;
- rlicB c:i1 I
,u-7
.SEE DETAIL JI A (.J I !
RNS¢B
~
I KC,/(,
fcB XP¢Sl8.9 XPI/Jsl8!J E.S
!au1110 CONTROL.SWITCH FCV2SFCV24 FCV23 FCV22
-rr--'cs,~'-rr-
- ~
I
,24-B
°' ::t I
1 I
RNS0B
~
u
~ i I
1XP!l>S188
~ Cl I
I D POS/88
- ,. IL I
XSV/88 _] OPE.N
~ ~
--7 XP¢.5l88 I
I I
SV/88 I
FCV2S I
1 JG XP0St88 AJ. Pos1ea OPc.N NI xe~
NI SA CNV
~ XSV/88
~NI I ~1' Nf--<,--_J-,-_______ __,
,3R XEJ!!§_/89 Ack POS/89 CLOS(;
XPfjJ/89 FCV22 USED AT LOCATION CB SPRING Re.TURN TO N£UTRAL CONTACTS POSITIONS INt
- OPEN
~I-A X
-ii-B X
-II-C X
-ti-D X
XSVI82 REMARKS GREEN LT-SPARE.
SPARE*
SEAL IN GB y-0-NI Ni-DETAIL 0A N FD!<: SV/132.& S V/81p VALVE OPEN POSITION SWITCH P0S/8B, POS!Blo,POS/84, f'OS/82 POSil"ION-S FCV 25.STEAM GEN 2-I MAIN I.SOL. BY-PASS VALVE CKT Nr,; I0/88SVO/
CONTACTS CLOSE\\'~~ REMAAl'.s OTHER MAIN ISOLATION BYPASS VALVES S!M!LAl'T.XCEPT AS -SHOWN ON TABLE VALVE DESCRIPTION DC CIRCUIT
,SOLENOID V/tLVe VALV Pas MAINS~AM !..IN /SOL.
N'l CKTN'?
Ng NQ LOC.
CLOSE OPEN DEVICE LQC.
CONTACT Ef:FDS FCV25 SG2.-I MAIN !SOL 8~ 11.9D IOIB8SVO/ 188 XSVI~~
/83 188 KGIG tJ.!§ ~}~~ MUX05-24 -i FCV84 SGZ-Z /\\MIN ISOL Brf'ASS 217D IOl87SVO/ /87
/8{;, xsv,are
/8-S 184 KC,23 RNS¢B '~' ? MUX or; -2 2 - I 1';4,.-
FCV22 SC:. 2-4 MA IN IS OL BYA'IS.S 31.SD IOl82SVOJ 182 XSV/82 183 182 KC2.3 RNSI@
_:~
, 'MUX07-IC/ I
_"l"71'_.
-fl-A X
RED LT.
-fl-13 X
SPARE
-fl-C X
MONITORLl
-ft-D X
SPARE VALL-'£ CLOSE POSITION SWITCH POSl89, POSl87, POS/85, f'OS 183
~
LOC XP~S37',
X1'4537B.
)(P~>380
):,ff)B82.
-~
E,fFOS ALAf.M CKT NO MAIN STM JSoL.V MUXOG-2/-3 MUXX,-2/-4 AY04-MD
!IJUX0?-/8-3 MUX07-ll3-4 l -,~
0:,
>(
£EAL-IN VALVE CLOSE POSITION SWITCH POS 821, F'OS 823., Po5 b23, FOS 825 LOC. Xf'¢s 821_ XP¢.5 82.~ XP¢s !/23, XP¢S 825 PUSHBUTTON SWITCHES SW NO.
PB813A P881:f;B P/3814-A PBB/4-6 TE:RM BLI<. 'Tt?AIN I; 1../X; TRAIN e Lb:,.
807-1, '2
- RN5P, RNSTB_
1309-1,'2 RNSIA RNSTB B07-5, ~
~SIA f3.NS1B B09-51G f<NS[A Rt-/SIB KEY DWG.
SECTION 5
DATE I 0/26/98 I DESCRI PT ION OWN.
I FAZ I I Revised pe-FCT 023281 R. E.
IND EP.
VER I Fl ER P. E.
IIXG2 KBB2
!3.
TO BE REWIRED M-lEN SWITCHES A FCE RE.PL,VCC:P.
EQUIPMENT LOCATION NUMBER5 CS, -
CONTROL 130t>.RO CCNDE!v5AT[ f fEeDWATE'P.i@) 2VB3)
P.NS@A -
--- NUCLEII.R SAfEGaUARD OUTPUT RAO~ 'A"
)(,fGV41 -
FLOW C.ONTP.OL VALVE fCV41
( AIR OF~RATED)
RNSTA -
NUCLEAR SAFEGUARD TEST RACK TRAIN A CNC2 -
- -- CONTROL BOARD REACTOR COOLANT CNV- -
CONTROL SOARD CHEMICAL 8,, VOLUME CONTROL BTHl/0 -
- -- TERM INAL OOX AREA H N£ 110 REFERENCE DRAWINGS
- 1. DE~CF'.IPTION Of ELEC:.f. SC\\.;EIIIATIC DIAC.RAW\\ SYMBOLS ANO C.IRCUIT DESIG,IJATIOl,)5 -
owe.. 050003
- 2. J;;QlJIPM*IJf LOCATION IJUMBE"RS ------- owc../OJO/J
.3. Pl Pl ~G. $Cll6'1'¥\\AT IC. -
TURI!>! IJE. !:.HAM ~\\JPPL.Y SYS, -
DWC., 10 ll0 0 4 4* !IJSTRUMENT sqtEMMIC.-
fLOW INSfRUt,11ENT 5'f$, -
OW(i. \\ O~O,l 5, SiNGcE l/NE ME.TER ~ RELAY OIAG. Ii sV D t >Y>TEM -
DW6. 44it40
- 6. MAIN STfAM VALVr - ---
- RH. bi,30~9 7,@.UNCTION DIAG~AM;,----- ---------- REC-603195
- 8. @.SOLID.STATE. P~O,E.C.T\\ON 5YST"E.M- ---- FIE.C.
G63?31 S, *
.SCHEMATIC DIAC,RA"1 MAIN ANNUNCIATOR SHE.ET o9 -
DVJq, 500718
- 10. SCHEMATIC DIAGRAM MONITOR LIGHT BOX D DWG. 4414-55 II.
BLOCK DIAG.*ER FDS AN/) TECH. SUPPORT Cf.NTER ---DWG 445297 l'l.. SCHEM. DIAG. SSPS OUTPUT RELAYS, TRAIii A, TRAIN B _
DWGS 503089, S03D'l3 NUCLEAR SAFETY RELATED VALVE NOS: FCV 25, 24, 23, 22, 41, 42, 43, 44 CO0RD I NA Tl ON
- NUCL, MECH.
ELEC.
CIVIL PI PING I&C UN IT 2 ELECTRICAL SCHEMATIC DIAGRAM MAIN STEAM ISOLATION VALVES DIABLO CANYON POWER ::,LANT
~
A B
C P. G. &E. SYSTEM PHASE SEQUENCE A-C-6 DWG SCALE BILL OF MATL SUPSDS SUPSD BY SHEET NO.
I OF REVIS I ON INFORMATION PACIFIC GAS AND ELECTRIC COMPANY SAN FRANCISCO, CALIFORN IA 44 I 296 I IEI
~
FOLD F~
<.O en N
'SI"
'SI"